Datacomm Method of Procedure

Date:

10-11-2014

26/
Author: Paul Marsal
Title:

VRP Upgrade to
V600R006C00SPC300 to
NE40Es in IP Backhaul for
Access Network (replacing
CF Card)

Tel.
No:
Fax
No:

Method of Procedure
OFFICIAL MOP PLAN
A MOP is required for hardware modification, expansions, feature and/or software additions, device modification
(replacements), where a reboot is required.

The MOP template includes all sections that could be required for the project.

VRP Upgrade to V600R006C00SPC300 to NE40Es in IP Backhaul for Access Network


(replacing CF Card)

Type of procedure:

Brief description:

Client:

Movistar

Site Name:

Country:

City:

VRP Upgrade to V600R006C00SPC300 to NE40Es in IP Backhaul for Access Network (replacing CF


Card)

Movistar

VENEZUELA

Nationwide

1
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

Approval and Signature of Responsible people.

________________________________
*Regional Technical Support Reviewer
________________________________
*Telephone and Fax Number
* via electronic email

2
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

APPROVAL AND SIGNATURE OF RESPONSIBLE PEOPLE. .......................................................................... 2


1.

PURPOSE OF THE ACTIVITY ........................................................................................................................ 4


1.1
1.2
1.3
1.4

2.

Schedule .................................................................................................................... 4
Site Access ................................................................................................................ 4
Contact list ................................................................................................................. 4
Responsibility Matrix ................................................................................................ 4

SOFTWARE CONSIDERATIONS (IF APPLIES) .......................................................................................... 5


2.1

Components compatibility ....................................................................................... 5

3.

HARDWARE CONSIDERATIONS .................................................................................................................. 5

4.

UPGRADE ........................................................................................................................................................... 5
4.1
Initial Verification (40 minutes + Customer verification time) ............................. 5
4.2
VRP Upgrade of ROU-VAL-0PE-001 (2 hours 20 minutes)Error! Bookmark not defined.
4.3 Verify the upgrade of NE40E-8 ROU-VAL-0PE-001 (40 minutes + customer verification time) .... 11

5.

10G BOARD EXPANSION ............................................................... ERROR! BOOKMARK NOT DEFINED.

6.

SERVICE INTERRUPTION ............................................................................................................................ 12

7.

ROLL BACK ..................................................................................................................................................... 12


Step 4. Execute the steps from point 4.3 in final verification ................................ Error! Bookmark not defined.
Scenario 2: (2 hours) ............................................................................................. Error! Bookmark not defined.

8.

COMMENTS ..................................................................................................................................................... 12

3
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

1.

Purpose of the activity

BRIEF DESCRIPTION OF THE ACTIVITY:

1.
1.1

VRP Upgrade to V600R006C00SPC300 to NE40Es in IP Backhaul for Access Network (replacing CF Card)

Schedule

INDICATE THE HOURS IN WICH IT WILL BE PERFORMED AND THE OBJECTIVES TO FULFILL. INFORMATION INTHIS SECTION
MUST MATCH THE INFORMATION FROM THE PROGAM MANAGER.
FROM 10:00 P.M. TO 11:00 A.M BEGINNING DATA COLLECTION AND VERIFICATION
FROM 11:00 A.M.TO 1:20 A.M. START UPGRADE PROCEDURE
FROM 1:20 A.M. TO 2:00 A.M. TROUBLESHOOTING TIME
FROM 2:00 A.M. TO 4:00 A.M. ROLLBACK TIME

1.2

Site Access

PROVIDE THE SITE SPECIFICATIONS AND INDICATE IF THE ACCESS IS RESTRICTED.

Movistar Nationwide
1.3

Contact list

PROVIDE ALL THE NUMBERS TO CONTACT THE INVOLVED PERSONS.

Paul Marsal 04242372625


Carmen Obaldia 0412 3242643
Danny Duque 0412 2567887

1.4

Responsibility Matrix
Project task

Client responsible

Huawei responsible

Ending time
Initial verification from
10:00pm. Start upgrade
process at 11:00pm. then
from 1:20am until 2:00am
for troubleshooting and from
2:00am until 4:00am
rollback

VRP Upgrade to
V600R006C00SPC300 to
NE40Es in IP Backhaul for
Access Network (replacing
CF Card)

4
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

2.

Software considerations (if applies)

2.1

Components compatibility

HARDWARE AND SOFTWARE COMPATIBILITY ELEMENTS

3.

Hardware element

Actual Version

Active software upgrade

Planned version for the


upgrade

NE40E

V600R001C00SPC800

V600R006C00SPC300

V600R006C00SPC300

Hardware Considerations

REQUIRED HARDWARE TO PROCEED WITH THE MOP ACTIVITIES

Hardware element

Version/Element

BOM

Quantity

CF card 2GB

N/A

N/A

4.

Upgrade

4.1

Initial Verification (40 minutes + Customer verification time)

Collect the following information before performing the upgrade.


Step 1. Verify the current configuration of the router NE40E (20 minutes)
-

Display the current configuration using the command display current-configuration

Display the VRP version of the device using the command display version

Display the state of the device using the command display health

Display the devices boards status using the command display device

Display the alarms of the device using the command display alarm all

Verify if there is space in cfcard using the command dir cfcard:/

Display the interfaces status using the command display interface brief

Verify the status of IS-IS protocol on active interfaces by running the command display isis interface
(the status must be UP).

Verify IS-IS peer relationship with neighbors by running the command display isis peer (the status
must be UP).

Verify BGP peer status with the command display bgp peer (The status must be established).

Display the routing table using the command display ip routing-table (statistics).

Verify the infotmation of all ldp peers display mpls ldp peer
5
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

Verify the statistics of all LSP display mpls lsp statistics

Very all LDP sesions display mpls ldp session all

Verify the vpn4 routes display bgp vpn4 all peer/routing-table statistics

Verify FIB table with the command display fib statistics all

Step 2. Movistars Staff will perform additional tests to verify the correct performance of the network by consulting
all the involved areas (20 minutes)

4.2 Obtaining Upgrade Reference Documents:

To obtain the system software (.cc), paf.txt, license.txt, and other documents, contact Huawei technical support
personnel or visit http://support.huawei.com.
Assume that ME60 V600R005C00SPCb00 is used. To obtain reference documents for this version, perform the
following steps:

1 Visit http://support.huawei.com.

Go to step 2 to register if you log in to the website for the first time. If you are already
a registered user, go to step 3.
2 Click Register and follow instructions to complete the registration procedure. If
registration succeeds, you will receive your user account and password in your input box.
Keep your password secure.
1.

Click Login, and enter your user name, password, and the verification code.

2.

After the login succeeds, choose Support > Software Center.

3.

In the Software Center page, choose Version Software > Data Communication
Product Line > Network Access > NE40E. The series are listed on the left.

4.

In the navigation tree, choose Quidway NE40E> NE40E V600R006C00SPC300.


The software file list and document list are displayed.

5.

Click a required file name and follow instructions to download the file.

PAF and License Files:


The V600R005C00SPCb00 system software provides a set of core PAF and license files by default.
6
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

During an upgrade, choose either of the following types of PAF and license files for system startup:

Default PAF and license files: The system can directly load these files from system
software but not a CF card during startup.

User-defined PAF and license files: These files are uploaded to a CF card, and
commands are used to allow the system to load them at the next startup.

Ensure that all necessary network cables and console interface cables are available. Obtain a spare LPU for each
working LPU or at least for each type of LPU. Get a spare SFU ready for each type of SFU and a spare MPU for
each type of MPU.

Login through the console port: The non-authentication mode has been canceled. When you log in for
the first time, you must configure a password and keep this password properly.

Save the configuration file of the source version: If the upgrade fails, you can roll back the ME60 to the source
version using the saved configuration file.Save the configuration in a .txt file.

4.3 Replacing CFcard:


Huawei authorized CF card is required to be purchased; otherwise all unexpected issues are
independent of Huawei.
Beside all files in current CF card, the target software package and target patch files can be copied
to new CF cards before upgrade.
CF card does not support hot plug.
New CF cards delivered by Huawei have been formatted already, and can be used directly.
There is only one CF card on of NE40E , and it is on the panel of MPUA. For other types of
MPU, CF card on the panel is CF card2. The other CF card is inside the board. CF card 1 location
on Non-MPUA (NE80E MPU):

7
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

Figure 1. CF card 1 location on Non-MPUA (NE80E MPU)

Copy current software package (.cc), current patch (.pat or .cc), configuration file, GTL
License, paf, license, constant interface index file (private-data.txt), new software package
(.cc), new patch (.pat or .cc), new configuration file to CF card via CF card reader. If the
device needs to be upgrade, it would be considered that copy both target software package
and patch to new CF card. Please save all before any operation.
Locate to CF card: Before replacing CF card, engineer needs to confirm the location of
chassis and slot ID of the MPU and label on it to avoid mis-operation.
Confirm if the being replaced CF card belongs to master MPU: Check ACT indicator light,
on means it is master MPU, off means slave one.
Run command power off slot slot-id or keep pressing offline button to cut off slave MPU.
Pull out slave MPU and replace current CF card with the new one.
CF card2 is used to store log files. Please concern for copying expected log files to new CF
card, and then substitute CF card2. All files in CF card2 do not impact any for live network.
Push the slave MPU back to slot after replacing CF card. And check MPU state with CLI
display switchover state after slave MPU becoming registered and stable, then run
command slave switchover.
After completing slave switchover and everything is stable, repeat step 3 to 6.
----End
Replacement the CF Card
*Power Off current Slave MPU boards off-load and plug it out.
* Replace the inner old CFCARD with the new 2G CFCARD.
* Plug in the slave MPU board.
1)
2)
3)

Use the command display device to check the MPUs working status. Display startup to check the startup
information.
Dir the slave#cfcard:/ to confirm the size of files such as .cc, patch, and configurations.
Save current configuration.

Use the command slave switchover to switchover current Master MPU and Slave MPU board.
Use the command display switchover state to check the MPUs status, until Realtime and routine backup.
Power off current Slave MPU and plug out, replace the new CFCARD, same method as above.
1)
2)
3)

Use the command display device to check the both MPUs working status. Display startup to check the startup
information.
Dir the slave#cfcard:/ to confirm the size of files such as .cc, 8patch, and configurations.
Save current configuration.
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

* Replace the inner old CFCARD with the new 2G CFCARD.

4.4 Specify the system software to be loaded to both MPUs for the next startup.

Step 1. Activation/Deactivation of GTL Licence (5 minutes)


- Upload the file to the router , with the following command tftp get name.dat
- Copy the file to the slave MPU with the command copy cfcard:// name .dat slave#cfcard://name.dat
- Use the command Display license to check if the license is active
- Deactivate the license with the command undo license active.

Step 2. After complete the download of the upgrade files, run the command dir cfcard: and dir slave#cfcard to
check that all files are in CFcard and Slave CFcard including name, size and modification date. (5 minutes)
Step 3. Verify that there is no patch running with the command display patch-information (5 minutes)
-

If there is a patch running, use the following commands to delete the patch from MPU and LPU
Use the command patch delete all to delete patch files from MPU and LPU.
Use the command reset patch-configure and reset patch-configure next-startup to eliminate patch
configuration to the next restart.

Step 4. Specify the VRP to be used in the next restart (5 minutes)


-

Change the VRP version to be used in the main board at the next restart with the command startup
system-software V600R006C00SPC300.CC

Change the VRP version to be used in the secondary board at the next restart with the command
startup system V600R006C00SPC300.CC slave-board

Verify the new startup configuration with the command display startup

Step 5. Specify the configuration file to be used in the next restart (5 minutes)
-

Change the configuration file to be used in the next restart with the command startup savedconfiguration config_new.cfg

Verify the new startup configuration with the command display startup

Step 6. Specify the PAF and L ICENSE to be used. (5 minutes)


-

Set to use default license file with the command startup license default and startup license default
slave-board.

Set to use default file PAF with the command startup paf default and startup paf default slave-board.
9
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

Display system startup configuration by running the command display startup

Step 7. Specify the patch to be used in the next startup (5 minutes)


-

Specify the patch to be loaded by the main board during the next restart with the command startup
patch cfcard:/patch.pat

Change the patch to be loaded by the slave board during the next restart with the command startup
cfcard:/patch.pat slave-board

Verify the system startup configuration with the command display startup

Execute the command patch-state run all to activate the patch used during the next restart.

Step 8. Check versions.


-

To check if the original version match with the target version put the command check startup
To check if the original version match with the target version put the command check system-software
startup

Step 9 Upgrade the BootROM on each LPU, SFU, and MPU.

Upgrade BootROMs on all LPUs, SFUs, and MPUs step by step.


<HUAWEI> upgrade lpu all cfcard:/V600R006C00SPC300.CC bootrom
<HUAWEI> upgrade sfu all cfcard:/V600R006C00SPC300.CC bootrom
<HUAWEI> upgrade mastermpu cfcard:/V600R006C00SPC300.CC bootrom
<HUAWEI> upgrade slavermpu cfcard:/V600R006C00SPC300.CC bootrom

Step 10. Reboot the equipment to load the new system software: (35 minutes)
-

Restart the device with the command reboot

NOTE: The restart of the equipment could take much time because of the board version change, the
average time is about 20 minutes, depending of the configuration there is an additional time until all
services are recovered.

Step 11. Final verification after upgrade (5 minutes)


-

Verify the files used during the restart with the command display startup

Step 12. Software switchover of the slave MPU after restart (10 minutes)

10
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

Verify switchover status with the command display switchover state

Set software switchover capacity with the command slave switchover enable

Verify the software switchover with the command display switchover state

4.5 Verify the upgrade of NE40E-8 ROU-PLC-0PE-001 (40 minutes + customer verification
time)
Step 1. Verify the current configuration of the (10 minutes)
-

Display the current configuration using the command display current-configuration

Display the VRP version of the device using the command display version

Display the state of the device using the command display health

Display the devices boards status using the command display device

Display the alarms of the device using the command display alarm all

Verify if there is space in cfcard using the command dir cfcard:/

Display the interfaces status using the command display interface brief

Verify the status of IS-IS protocol on active interfaces by running the command display isis interface
(the status must be UP).

Verify IS-IS peer relationship with neighbors by running the command display isis peer (the status
must be UP).

Verify BGP peer status with the command display bgp peer (The status must be established).

Display the routing table using the command display ip routing-table (statistics).

Verify the infotmation of all ldp peers display mpls ldp peer

Verify the statistics of all LSP display mpls lsp statistics

Very all LDP sesions display mpls ldp session all

Verify the vpn4 routes display bgp vpn4 all peer/routing-table statistics

Verify FIB table with the command display fib statistics all

11
Huawei Technologies-"Proprietary"

______________________________________________________________________________________________
Datacomm Method of Procedure

5.

Service Interruption
INDICATE BELOW WITH X IF THE SERVICE WILL BE
INTERRUPTED

YES: X

NO:

IF YOUR ANSWER IS YES PLEASE INDICATE THE DEVICES INCLUDED


IN THE INTERRUPTION AND IF IS TOTAL OR PARTIAL

6.

TOTAL

PARTIAL

TIME

Roll Back

Roll back scenarios are contemplated for this upgrade.

INICIAL
TIME

END
TIME

PRECAUTION:
Steps before roll back:

1.

7.

Follow all the steps 4.3 and 4.4 with the initial CFcard and then reboot the router.

Comments

ADDITIONAL COMMENTS.

12
Huawei Technologies-"Proprietary"

3:00am

5:00 am

3:00am

5:00 am