You are on page 1of 73

2011 Bentley Systems, Incorporated

AutoPIPE V8i SELECTseries 4 (v9.5)


Mark Upston
Director Structural Solutions & PipeStress

New AutoPIPE V8i SELECTseries4 (v9.5.0.x)

Release date, November 2012


2 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Summary

PID
FEED

PlantFLOW
Fluid Flow Analysis

Transient
Flow
Analysis

PULS

Microprotol

FEA

Vessel Design

Pulsation Analysis
Equipment Check
Pumps, Turbines,
Compressors

ASME Flange
Design

AutoPIPE Nozzle
Nozzle/Vessel Limits

3D Model

AutoPIPE
Pipe Stress Analysis

PID
FEED

PlantWise

Navigator
Isos

Marked-Up
StressISO

3D
Model

Conceptual 3D
Design

Pipe Support
Vendor

AutoPLANT, PlantSpace,
SP3D, PDS, PDMS
Third Party Programs

3 | WWW.BENTLEY.COM

Hot Clash
Detection

3D Modeling

Drawings/
Reports

ProjectWise
Project
Management

STAAD
Structural Analysis

2011 Bentley Systems, Incorporated

DigitalPlant Pipe Stress Analysis WorkFlow

More than 70 new features

4 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

AutoPIPE V8i SS4 (v9.5) Enhancements

New Advanced Buried


Piping Design - Traffic &
Seismic loads

Piping Codes:
Enhanced Color Graphics
Pipe Properties /Segment

Productivity Improvements
Flange Design

5 | WWW.BENTLEY.COM

FRP piping code ISO 14692


Nuclear JSME 2008

Interoperability
Improved DGN i-model Export,
PCF/PXF import & Caesar Import

2011 Bentley Systems, Incorporated

AutoPIPE v9.5 Major Highlights

2011 Bentley Systems, Incorporated

Design Codes

JSME 2008 Design code and JEAC material library


Re-certification of Japans nuclear power plants

7 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Piping Code : New JSME 2008 code

Seismic Levels A & As combined in new S level


New Service levels S, B, C, None.

Dynamic Seismic Cases


All SAM Levels Supported
8 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Significant Changes in the JSME 2008 Edition

Analysis Summary

9 | WWW.BENTLEY.COM

Code Compliance Load Cases

2011 Bentley Systems, Incorporated

JSME Reports & Load Combinations

New ISO 14692 FRP Piping Code (2005 Addenda)

New FRP Libraries


10 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Piping Codes : New ISO 14692 FRP Code

Pipe ID

Long Term Hoop and Axial


Allowable Envelope
Stresses
Poisson Ratio and A3
Factor for Cyclic Service
11 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

FRP Pipe Properties

Smooth / Miter

Qualified Stress from


Manufacturer

Biaxial Type and Ratio

Qualified Component

12 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

FRP Bend Component

2011 Bentley Systems, Incorporated

FRP Material Library

13 | WWW.BENTLEY.COM

ISO 14692
FIBERBOND
AMERON
FIBERCAST
SARPLAST
CONLEY
WAVISTRONG
HARVEL
REINFORCED PLASTIC
SYSTEMS

Component Failure Stress Envelopes Supported


Fully Measured

Component
Plain Pipe
Bend
Tee

14 | WWW.BENTLEY.COM

Fully
Measured
Axial & Hoop
1:1 Stress
Ratios > 0.1
NA
NA

Simplified

Simplified

Rectangular

Axial & Hoop


1:1 Stress
Ratios <=0.1
Biaxial ratio
R<1
Biaxial ratio
R<1

Biaxial ratio
R => 1
Biaxial ratio
R => 1
Biaxial ratio
R => 1

Rectangular

Code Compliance

2011 Bentley Systems, Incorporated

Piping Code : ISO 14692

2011 Bentley Systems, Incorporated

Analysis

Based on exact solution of linear dynamic equations of motion


Improved accuracy as problems due to period elongation or
numerical damping are avoided

Wilson- is the only available method in CAESAR II


unconditionally stable for >1.37. However, this does not
mean solution is accurate.
16 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New PieceWise Exact Time History Method

17 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New PieceWise Exact Time History Method

18 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Time History & Response Spectrum Dialogs

Time History Profile


o New Option : Imposed
Displacement
Time History Location

XBD
7 4
0.000000
0.020000
0.030000
0.050000
0.060000
0.061000
0.120000

19 | WWW.BENTLEY.COM

.0
2.
2.
.2
-.7
.0
.0

2011 Bentley Systems, Incorporated

New Displacement Time History

Type of Vibration

AutoPIPE Solution

1. Mechanical

Harmonic Displacement Analysis

A. Machinery Unbalanced Forces


and Moments
B. Structure Borne Vibrations
2. Pulsation

Harmonic Force Analysis

Flow induced vibrations due


to compressors & pumps
3. Pressure Surge, Hydraulic
Hammer

20 | WWW.BENTLEY.COM

Force Time History

2011 Bentley Systems, Incorporated

Solution for Piping Vibration

21 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Improved Dialog for defining


Harmonic Load

22 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Visualize Individual Frequency Plots or


Harmonic Superposition

23 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Model Transient Vibration Effects by


Applying Time History Loads

Buoyancy will now be applied to segments


NTL import/export
Enabled by default

24 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Limit Buoyancy to Selected Segments

Soil weight on top of pipe (including


effect of water table)
Surface live loads (Highway, Railway,
Airport, and user defined)
Effect of seismic wave propagation
along pipeline (calculated as an
equivalent temperature rise)
Imposed displacement of support due
to building settlement

25 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Advanced Buried Pipeline Design

Circumferential wall bending stress (Adams et. Al., ANSI AWWA


C150, and ASCE 2001 w/2005 addenda)
Ring buckling category
Seismic + Thermal category (Seismic includes SAM and wave
propagation effects)
Building settlement category

New
Soil Stress
Categories
26 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Soil Analysis Stress Categories

2011 Bentley Systems, Incorporated

Post Processing

Code Report
Code Combinations

28 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

BS7159 User Hoop and Long Allowables

Code Combinations

29 | WWW.BENTLEY.COM

Non-Code
Combinations

2011 Bentley Systems, Incorporated

1000 Code and Non-Code Combinations

30 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Modal Frequency Shown on Plot

Scrolling through the Combinations


using VCR Buttons updates both
Deflected Plot and Results

31 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Deflected Plot & Results Updated

2011 Bentley Systems, Incorporated

Performance

Option

Method
Ctrl+Enter

Line Number

Drag
Copy Down

latest v9.5
build

9.4.0.19
Check

48* sec

1 sec

Uncheck

48*

sec

1 sec

Check

50*

sec

6 sec

Uncheck

50*

sec

6 sec

Check

51*

sec

2 sec

Uncheck

50*

sec

1 sec

Model: BLNE2.DAT with 221 segments.

33 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Segment Grid Optimization (up to 50 times)

2011 Bentley Systems, Incorporated

Modeling

Insert / Modify Run dialog


Insert / Modify Bend dialog
Insert / Modify Valve dialog
Insert / Modify FlexJoint dialog
Insert / Modify Reducer dialog
Insert / Modify Tee Point dialog

In AutoPIPE following
represent the following.
Theta
r radius
z Elevation

35 | WWW.BENTLEY.COM

symbol

2011 Bentley Systems, Incorporated

Component Placement using Cylindrical Coordinates

Fluid density can change by temperature and pressure conditions including phase e.g. Steam
Change Fluid density for Static, and Dynamic load cases.

36 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Fluid Density Factor

37 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Pipe Identifier Tag e.g. 6 Bypass Line

Pressure Temperature Input Grid


New Pressure / Temperature Grid menu options :

Show
Show
Show
Show

Pressure Only
Temperature Only
Pressure and Temperature Only
All

38 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Demo

39 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Plot Reference Point Tag

Go to Point Dialog

Go to Origin

Origin Symbol and text

ViewSettings Show Origin checkbox on the Plot

40 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Where is the Origin? - New Goto Origin

Color Plots of Model Data


Pipe Properties
Toggle Property, Component
and Xtra Data On/OFF while
Still Editing the Model

41 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Improved Graphical Show Options

Hint: Continue to model while


viewing color plot of segments

42 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Color Plot of All Visible Segments

Hint: Edit the Model while viewing


color plot of segments

Pipe Thickness

New Floating Legend

43 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Color Plot of Pipe Properties

Insulation Thickness

44 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Color Plot of Pipe Properties

45 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Isolate and Show Connected Segments

2011 Bentley Systems, Incorporated

Reports

47 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Segment data report

All the Load Combinations which have the highest FAIL


Equipment Ratios are identified

48 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Equipment Summary Report

2011 Bentley Systems, Incorporated

Productivity Enhancements for new


Flange Analysis & Design Module

Flange Checks to ASME VIII Div 1 & 2 : 2010, ASME III


Appendix XI and ASME III NC 3658.1 (b) (ANSI check)
Material to ASME II, B31.1 or B31.3

50 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Flange Analysis & Design Module

Flange Material Library Based on Flange Design Code

51 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Default Flange Library

Modify Flange from Flange Analysis


Flange Select synchronized with Plot

52 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Flange Synchronization

Restore Sort Order [More Options]

53 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Flange Sort

Hide Incomplete Flanges

54 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Color Coded Incomplete Flange Data

55 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

ANSI Check - User Defined Pmax Pressure

Lethal Service

56 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Analysis Bolt Spacing Correction

New Flag /n to perform automated flange analysis


New Flag /l to Create the model input listing (*.RPT)

e.g. AUTOPIPE.EXE VERTICAL HEATER SPOOLS.DAT" /s /l /n /b /y

Switches

57 | WWW.BENTLEY.COM

Description

/s

Perform a static analysis.

/l

Create the model input listing (*.RPT).

/n

Perform a flange analysis.

/b

Create the batch report file (*.OUT).

2011 Bentley Systems, Incorporated

New Batch Processing switches

2011 Bentley Systems, Incorporated

Interoperability

Bentley Products
Project
Wise

STAAD

Auto
PLANT

Plant
Space

PDS

PDMS

Open
Plant

ADL
Pipe

Win
NOZL

Plant
FLOW

PULS

CATIA

ME101

AutoPIPE

3rd Party Products


Caesar

SP3D

CAD
Worx

Solid
Works

Inventor

AutoPIPE

CAD Products
59 | WWW.BENTLEY.COM

59

2011 Bentley Systems, Incorporated

AutoPIPE Product Interoperability Matrix

Improved Caesar 2011 (v5.3) compatibility

Importing more PCF Component Data

Improved Roundtrip with AutoPLANT

2011 Bentley Systems, Incorporated

Interoperability & Import /Export

AutoPIPE
60 | WWW.BENTLEY.COM

61 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Hot Clash Detection

Automatic Conversion from Y-Vertical to CAD Z Vertical axis

AutoPIPE

62 | WWW.BENTLEY.COM

MicroStation

2011 Bentley Systems, Incorporated

Using AutoPIPE & Navigator Hot Clash Detection

To Avoid Design Mistakes and Operation Failure

Bentley Navigator or MicroStation


63 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Using AutoPIPE & Navigator Hot Clash Detection

Caesar has no Flange component AutoPIPE now has smart logic to


Convert Caesar RIGID Element to intelligent flanges in AutoPIPE with
Flange Spec, Flange Type and Pressure Rating

Flange = RIGID Element


Valve = RIGID Element
Flange = RIGID Element
64 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Smart Flange Conversion from Caesar

V9.4 : CII Flange -> Valve

Flange Size
Flange Type
Flange Rating
Flange Spec

65 | WWW.BENTLEY.COM

V9.5 : Intelligent Flange Conversion

2011 Bentley Systems, Incorporated

Smart Caesar Flange Import

2011 Bentley Systems, Incorporated

AutoPLANT / AutoPIPE Integration

~ 60 Supports

AutoPLANT

AutoPIPE
~ 60 Supports
67 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Intelligent AutoPLANT / AutoPIPE


PXF Supports Exchange v9.4

Flange type, Flange length, rating,


weight, weld connection, gaskets,
bolts

AutoPIPE

AutoPLANT

New Flange CAD Length


68 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

New Intelligent AutoPLANT / AutoPIPE


Flange Exchange v9.5

Actual CAD Flange Length imported

AutoPIPE

AutoPLANT or
PCF Formats from
SmartPlant, CADWorx,
AutoDesk or SolidWorks

69 | WWW.BENTLEY.COM

Weldneck Flange Graphic

2011 Bentley Systems, Incorporated

PXF / PCF 2-Point Flange Component

70 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

PCF Line Number & Class now Imported

Flexible Joint

Cross
71 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

PCF Components now Imported

72 | WWW.BENTLEY.COM

2011 Bentley Systems, Incorporated

Import AutoDesk Plant 3D Models

2011 Bentley Systems, Incorporated

Thank you

You might also like