This newsletter is the third in a series on variable measurement systems and how to understand the impact
these measurement systems have on your operations. Measurement systems are extremely important in
continuous process improvement. We must measure to know where we are. We use measurements to tell us if
there is a problem in the process or if a process change has improved the process.

Software (4)
Complete Teaching Guides
to SPC (9)

For measurements to be effective, they must be timely, accurate, and precise. Many of our customers, both
internal and external, rely on our measurements. So how do we provide measurements that are meaningful?
That is the purpose of this series of newsletters.

Special Offers (5)


PowerPoint Training
Modules (17)

Newsletter Sign-up
Click here to sign up for our
FREE monthly newsletter,
featuring SPC and other
statistical topics, case
studies and more!

Argentina
Australia
Austria
Belgium
Botswana
Brazil
Bulgaria
Canada
Chile

The first series covered stability of measurement systems and how to use control charts to monitor the stability
of measurement systems. In the last series we examined bias in measurement systems. Bias occurs when
there is a difference between the true value (reference value) and the observed average of the measurements
on the same characteristic on the same sample. In this newsletter we examine linearity of measurement
systems. Linearity is concerned with the bias throughout the measurement range.
If you have difficulty viewing this newsletter, it is on our website along with all past newsletters.
Best regards,
Bill

.
SPC for Excel is used
internationally including:

Greetings,

Linearity Definition
The third edition of the book Measurement Systems Analysis (published by AIAG) has the following definition
for linearity:
"The difference of bias throughout the expected operating (measurement) range of the equipment is called
linearity."
This means that you cannot assume constant bias throughout the measurement range. Possible causes of
linearity issues include:
Measurement system needs calibration
Poor maintenance on the measurement system
Problem with the master
Temperature
Humidity

http://www.spcforexcel.com/variable-measurement-systems-part-3-linearity

Page 1 of 6

Variable Measurement Systems - Part 3: Linearity | BPI Consulting

China
Colombia
Costa Rica
Denmark
Egypt
Estonia
Finland
France
Germany
Greece
Hong Kong
Hungary
Iceland
India
Indonesia
Ireland
Israel
Italy
Japan
Korea, D.P.R.O.
Korea, Republic Of
Kuwait
Liechtenstein
Malaysia
Malta
Mexico
Micronesia
Netherlands
New Zealand
Nicaragua
Nigeria
Norway
Peru
Philippines
Poland
Portugal
Puerto Rico
Romania
Russian Federation
Rwanda
Saudi Arabia
Singapore
Slovenia
South Africa
Spain
Sweden
Switzerland
Taiwan
Thailand
Turkey
Uganda
United Arab Emirates
United Kingdom
United States
Uruguay
Venezuela
Zaire

6/28/12 11:01 AM

Cleanliness
Poor measurement system design
The process for conducting a study to determine if there is linearity in a measurement system is given below. It
is important that the measurement system be stable (in statistical control) when the linearity study is done. This
is done by running a standard on a regular basis, plotting the results on a control chart and interpreting the
results for statistical control. How to do this was covered in the first series on measurement systems analysis.

Click here to access all our previous newsletters.

Linearity Study
The steps in a linearity study are given below. The key starting point is selecting samples to include in the
study. These samples must span the range of the measurement variation in the process. For example, if your
process output varies from 70 to 100, you want to select samples that span that range. You don't want to only
include samples in the 90 to 100 range. You linearity study will not be valid for the entire range. It is best to
have at least 5 samples over the range.
Another problem is determining the reference value for the samples. This can be done, for example, if you
have a master tool room. You may have to send out the samples to another lab which you know has better
precision than your lab.
The last issue is to be sure that one operator measures each sample at least 10 times. The samples should be
measured in a random order.
Thus, the steps in conducting a linearity study are:
Select at least 5 samples the measurement values of which cover the range of variation in the
process
Determine the reference value for each sample
Have one operator measure each sample at least 10 times using the measurement system

We offer on-site training in process improvement as well as training material you can customize and
teach yourself. Click here for more information.

Analyzing the Results


To show how to analyze the results, we will use the following example. A lab supervisor wants to check the
linearity of a new measurement system. He collects five samples over the range of production and determines
the reference value for each sample. He then has one operator run each sample 10 times in a random order.
The results are given below.

To analyze the results, follow the steps below.


Calculate the bias for each measurement. This is done by subtracting the reference value from the
http://www.spcforexcel.com/variable-measurement-systems-part-3-linearity

Page 2 of 6

Variable Measurement Systems - Part 3: Linearity | BPI Consulting

6/28/12 11:01 AM

measurement result. For example, the measurement result for the first measurement for the first sample was
7.7. The bias is then 7.7 - 7 = 0.7. The bias for all measurements is shown in the table below.

Calculate the average bias for each sample. This is done by adding up the bias results for each sample and
dividing by the number of times each sample was tested. For example, for sample 1, the sum of the bias
results is 4.9. Since the sample was tested 10 times, the average bias for sample 1 is 4.9/10 = 0.49. The
averages for all samples are shown below.

Sample 1: 0.49
Sample 2: 0.16
Sample 3: 0.02
Sample 4: -0.28
Sample 5: -0.61

Plot the individual bias results and the average bias versus the reference value for each sample. The plot is
shown below.

Determine the best fit line for the average bias results and add it to the chart.
The best fit line is given by ybar = b1x + b0 where ybar = bias average and x = reference value for
each sample.

The easiest way to do this is to use Microsoft Excel. You can easily add the trend line by right clicking on the
chart and selecting "Add Trendline." You can also select the option to add the equation for the best fit line. This
equation is ybar = -0.132x + 1.408.

http://www.spcforexcel.com/variable-measurement-systems-part-3-linearity

Page 3 of 6

Variable Measurement Systems - Part 3: Linearity | BPI Consulting

6/28/12 11:01 AM

Determine the standard deviation (s) using the following equation:

where n = total number of measurements (number of samples * number of repeat measurements = 5 * 10 =


50), yi is the individual bias results and xi is the reference value. Thus,

Determine the 95% upper confidence band (UCB) and lower confidence band (LCB) for each value of x0:

where t(0.05, df) is the value for the t distribution for n - 2 degrees of freedom and 95% confidence. This is
available from Microsoft Excel using the TINV function. For 48 degrees of freedom, the value of t is 2.011. The
calculations for each value of the confidence band are not shown here.
Plot the confidence bands and the bias = 0 line on the chart. The final chart is shown below.

http://www.spcforexcel.com/variable-measurement-systems-part-3-linearity

Page 4 of 6

Variable Measurement Systems - Part 3: Linearity | BPI Consulting

6/28/12 11:01 AM

Our SPC for Excel software easily performs Measurement Systems Analysis. Click here.

Interpreting the Results


The results can be interpreted graphically and numerically. If linearity is acceptable, the bias = 0 line must fall
entirely within the confidence bands. This is clearly not the case in the above chart. So, there appears to be a
problem with linearity.
You can also analyze the results numerically. The question you want to answer is "Is the slope of the bias line
significantly different from 0?" To do this, you calculate the following t value:

The value of t for this data is 10.433. You compare this value of t to the critical t value for 48 degrees of
freedom and 95% confidence. As shown above, the critical value of t is 2.011. If the absolute value of the
calculated t value is greater than the critical value of t, then the slope is significantly different than zero. Since
10.433 is greater than 2.011, we conclude that the slope of the bias line is not 0 and that the linearity is not
acceptable. This issue must be addressed and corrected before the measurement system can be used.

Summary

In the first series, we started our analysis of variable measurement systems. The first step in analyzing the
performance of a measurement system is to ensure it is stable, i.e., in a state of statistical control. This is
determined by finding a master sample, measuring it over time, and plotting the results on a X-mR chart. The
X-mR chart is then analyzed for statistical control. It there are out-of-control points present, the causes of these
must be eliminated. Once there are no out-of-control points, the measurement system is stable and further
analysis can be done.
The next step is to ensure that there is no bias in the measurement. In the second series, an independent
sample method was introduced to accomplish this. In this newsletter, we examined linearity to ensure that
there is no bias over the range of measurements expected.
Next month we will continue our examination of measurement systems and examine gage R&R. This permits
us to determine how acceptable the measurement system is.
Thanks so much for reading our newsletter. We hope you find it informative and useful. Happy charting and
may the data always support your position.

http://www.spcforexcel.com/variable-measurement-systems-part-3-linearity

Page 5 of 6

Variable Measurement Systems - Part 3: Linearity | BPI Consulting

6/28/12 11:01 AM

Copyright 2012 BPI Consulting, LLC. All Rights Reserved.