You are on page 1of 2

BILL OF QUANTITIES - EXHAUST BLOWERS

QTY UNIT
SUPPLY
Sr
No

1
2
3
4
5
6
7
8

DESCRIPTION
Supply, installation and commissioning of low noise
level PP/ FRP exhaust centrifugal blowers
(flameproof motor) housed in 5mm PP & 5mm FRP
(Fire Retardant) thick with a extended pleanum
having 99.97% HEPA and 5 micron bag in bag out
filters. Pedestal and base frame of blowers is M.S
with epoxy coat with two coats. EN8 Shaft Bearings
of blowers should be of SKF, FAG or NTTF make.
Impeller with dynamic balancing complete skid
should be mounted on AVM's. Quote with
appropriate blower h.p for the cfm mentioned below.
EAU 5 13810 cfm, 90mm wg static (with VFD)
99.97% HEPA and 5 micron bag in bag out filters
EAU 6 14155 cfm, 90mm wg static (with VFD)
EAU 7 15365 cfm, 90mm wg static (with VFD)
EAU 8 4745 cfm, 90mm wg static 99.97% HEPA and
5 micron bag in bag out filters
EAU 9 4670 cfm, 90mm wg static 99.97% HEPA and
5 micron bag in bag out filters
EAU 15 3970 cfm, 90mm wg static 99.97% HEPA
and 5 micron bag in bag out filters
EAU 16 4315 cfm, 90mm wg static 99.97% HEPA
and 5 micron bag in bag out filters
EAU 17 1710 cfm, 90mm wg static 99.97% HEPA
and 5 micron bag in bag out filters
Supply, installation and commissioning of low noise
level PP/ FRP exhaust centrifugal blowers
(flameproof motor) housed in 5mm PP & 5mm FRP
(Fire Retardant) thick with a extended pleanum
having 10 micron . Pedestal and base frame of
blowers is M.S with epoxy coat with two coats. EN8
Shaft Bearings of blowers should be of SKF, FAG or
NTTF make. Impeller with dynamic balancing
complete skid should be mounted on AVM's. Quote
with appropriate blower h.p for the cfm mentioned
below.
EAU 11 5230 cfm, 65 mm wg static
EAU 12 8545 cfm, 65 mm wg static
EAU 13 5905 cfm, 65 mm wg static
EAU 18 8415 cfm, 65 mm wg static
EAU 19 6210 cfm, 65 mm wg static
EAU 20 7430 cfm, 65 mm wg static
EAU 21 1395 cfm, 65 mm wg static

GRILLS/DAMPERS

a
b
c
d
e
f

Butterfly dampers made out of 5mm thick


polypropylene sheets lined complete with PP shaft
and lock, SS operating handle for blower only
950 mm Dia
750 mm Dia
600 mm Dia
550 mm Dia
500 mm Dia
350 mm Dia

RATE

1
1
1

Nos.
Nos.
Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

1
1
1
1
1
1
1

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

3
3
3
3
1
2

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

AMOUNT

INSTALLATION
RATE

AMOUNT

Butterfly dampers made out of 5mm thick


polypropylene sheets lined complete with PP shaft
2 and lock, SS operating handle for PP grill module
a
350 mm Dia
70 Nos.
b
650 mm Dia
64(1 to17).
Nos. L.B.S. Marg, Vikhroli (W), Mumbai 400 083, India.
GMP Technical
Solutions Private Limited: Bldg. No. 14, CST No. 82,82
Tel.: 91 22 2576 1956, Fax: 91 2225712710. Website: www.gmpts.com E-mail: projects@gmpts.com
Works:Kurawala, Barotiwala,Kasauli, Solan, H.P. 174103 India Tel:91 9218466806, 91 9218466808, Fax:91 1792255227
AsMehta
per enclosed
drawingMr.
Grill
module
of 5 mm
Mr.Ajay
919816087474,
Sunil
Jain made
91 9815255554

TOTAL

GMP Technical Solutions Private Limited: Bldg. No. 14, CST No. 82,82 (1 to17). L.B.S. Marg, Vikhroli (W), Mumbai 400 083, India.
Tel.: 91 22 2576 1956, Fax: 91 2225712710. Website: www.gmpts.com E-mail: projects@gmpts.com
Works:Kurawala, Barotiwala,Kasauli, Solan, H.P. 174103 India Tel:91 9218466806, 91 9218466808, Fax:91 1792255227
Mr.Ajay Mehta 919816087474, Mr. Sunil Jain - 919815255554

You might also like