You are on page 1of 6

~)

I
I

The system is the solution


Century-Line@sleeves are engineered to
mate with Link-Seal@
modular mechanical
seals for a lifetime of leak-proof performancn
PSlffhunderline/Link-Sea/@isyour one-stop
source for everything you need to effectively
seal the annular space between pipes and
concrete barriers through which they pass.
Charts on the adjacent page
provide Century-Line@sleeve
model numbers for standard
size pipe along with corresponding Link-Seal@
modular
seal model numbers.

t
.

J
I

I
I

Century-line'" Sleeves
Model CS (16"length)
Weights and Dimensional Data
MODEL I.D. (In.)
(5-2
2.09
(5-3
294
(5-3-1/2
338
(5-4
403
(5-5
5.14
(5-6
6.14
(5-8
82]
(5-10
10.19
(5-12
12.26
(5-14
14.14
(5-16
16.18
(5-18
17.45
(5-20
19.12
(5-22
20.32
(5-24
22.76
(5-25
248]

J.D. (mm)
53.1
74.7
85.9
102.4
130.6
156.0
208.5
258.8
311.4
359.2
411.0
443.2
4856
516.1
578.1
630.2

Ibs.
0.70
1.30
1.50
2.00
2.80
3.60
4.80
6.40
7.20
11.20
12.00
15.50
17.50
21.00
22.00
23.00

\
Kg.
0.32
0.59
0.68
0.90
1.27
1.63
2.18
2.90
3.27
5.08
5.44
7.03
7.94
9.53
9.98
] 0.43

n
I

i
I

J
i
.r

Nailer End (ap

5 -j

I
,

n
Reinforcing Ribs
Nailer End (ap
Page I

I
Century-line@ Sleeves and link-Seal@ Modular Seals Sizing Charts for Standard Pipe

How to Order Century-line@ Sleeves


1. Locate chart that corresponds to the type
and size pipe being used.
2. Veritythat your pipe 0.0. matches the
actual outside diameter shown on the chart.
3. Indicate: quantity, model number (from
MODELNUMBERcolumn) and length of
sleeve required. [Example: I - CS-]0-] 6"]

How to Order Corresponding


link-Seal@ Modular Seals
1. Determine Link-Seal modular seal model to be used. See LinkSeal Modular Seal Brochure.
2. Indicate number of links required per seal (from LINKSPER SEAL
column), Link-Seal modular seal size (from LINK-SEAL
SIZEcolumn) and Link-Seal modular seal model (C, S-316, 0, OS-316, T
or FD/FS) from Link-Seal modular seal brochure.
[Example: 10- LS-475-S-316]

Steel and Plastic Pipe with Same


Outside Diameter

Cast Iron Soil Pipe (Extra Heavy)

PIPE
SIZE
fNom.)
1/2
3/4
I

()

MODEL
O.D.
(Inches) NUMBER
C5-2-*
0.840
C5-3-*
1.050
C5-3-*
1315

1-1/4

1.660

1- 1/2

1 .900

2
2-1/2
3
3-1/2
4
5
6
8
10
12
14
16
18
20
22
Ductile
PIPE
SIZE
fNom.)
2
2-1/4
3
4
6
8
10
12
14
16
18
20

Copper

ACTUAL

2.375
2.875
3.500
4.000
4.500
5.563
662-5
8.625
10.750
12.750
14.000
16.000
18.000
20.000
22.000
Iron Pipe

C5-3-*
C5-3-1/2-*
C5-4-*
C5-4-*
C5-5-*
C5-6-*
C5-6-*
C5-8-*
C5- 10-*
C5-12-*
C5-14-*
C5-16-*
C5-18-*
C5-20-*
C5-24-*
C5-25-*
C5-25-*

LINK-SEAL
SIZE
LS-200-**
LS-315-**
LS-300-**
LS-275-**
LS-275-**
LS-300-**
LS-200-* *
LS-300-**
LS-325-**
LS-300-**
LS-425-**
LS-475-**
LS-475-**!
LS-400-**
LS-400-**
LS-400-**
LS-400-* *
LS-525-* *
LS-525-**
LS-425-**

PIPE

LINKS
PER

SEAL

4
4
4
7
8
6
9
8
5
10
6
10
12
10
12
13
15
16
18
20

SIZE
INom.)
2
3
4
5
6
8
10
12
15

ACTUAL
O.D.
finches)
2.380
3.500
4.500
5.500
6.500
8.620
10.750
12.750
15.880

MODEL
NUMBER
C5-4-*
C5-5-*
C5-6-*
C5-8-*
C5-10-*
C5-12-*
C5-14-*
C5-16-*
C5-20-*

LINK-SEAL LINKS
SIZE
PER SEAL
LS-300-**
LS-300-**
LS-300-**
LS-425-**
LS-475-**
LS-475-**
LS-400-* *
LS-400-* *
LS-400-**

6
8
10
6
10
12
10
12
15

Cast Iron Soil Pipe (Service Weight)


PIPE
SIZE
(Nom.1
2
3
4
5
6
8
10
12
15

ACTUAL
O.D.
(Inches I
2.300
3.300
4.300
5.300
6.300
8.380
10.500
12.500
15.620

MODEL
NUMBER
C5-4-*
C5-5-*
C5-6-*
C5-8-*
C5-8-*
C5- 12-*
C5- 14-*
C5-16-*
C5-20-*

LINK-SEAL LINKS
SIZE
PER SEAL
LS-315-**
LS-315-**
LS-315-**
LS-425-**
LS-325-**
LS-575-**
LS-475-**
LS-475-**
LS-475-**

6
8
1I
6
7
10
14
17
20

(AWWA-Type)

ACTUAL
O.D.
MODEL
(Inches) NUMBER
C5-4-*
2.500
2.750
C5-5-*
3.960
C5-6-*
C5-8-*
4.800
C5- 10-*
6.900
9.050
C5-1 2-*
11.100
C5- 14-*
13.200
C5- 16-*
15.300
C5-20-*
17.400
C5-22-*
19.500
C5-24-*
21.600
C5-25-*

LINK-SEAL LINKS
PER SEAL
SIZE
LS-300-**
6
4
LS-325-**
LS-325-* *
5
LS-400-**
5
LS-400-**
7
9
LS-400-**
1I
LS-400-**
LS-400-**
12
LS-575-**
17
LS-400-**
16
LS-400-**
18
LS-400-**
20

Electrical Metallic Tubing (Thin Wall)


PIPE
ACTUAL
MODEL
-SIZE)
O.D.
fNom.) (Inches) NUMBER
C5-2-*
1/2
0.706
C5-3-*
3/4
0 922
C5-3-*
I
1.163
C5-3-1/2-*
1-1/4
1.510
C5-3- I /2-*
1-1/2
1.740
C5-4-*
2
2.197
C5-4-*
2-1/2
2.875
C5-5-*
3
3.500
C5-6-*
4
4.500

Tubing

PIPE
ACTUAL
O.D.
MODEL
SIZE)
(Nom.) (Inches) NUMBER
0.625
C5-2-*
1/2
3/4
0.875
C5-3-*
I
1.125
C5-3-*
1-1/4
1.375
C5-3-*
1-1/2
1.625
C5-3-*
2
2.125
C5-4-*
2-1/2
2.625
C5-4-*
3
3.125
C5-5-*
4
4 125
C5-6-*
6
6. I 25
C5-8-*
8
8.125
C5- 10-*
C5-12-*
10
10.125
C5-14-*
12
12.125

LINK-SEAL LINKS
SIZE
PER SEAL
4
LS-275-**
4
LS-315-**
4
LS-300-**
4
LS-300-**
LS-275-**
7
6
LS-315-**
11
LS-275-**
LS-325-**
4
L5-325-**
5
LS-325-**
7L5-325-**
9
LS-325-**
II
LS-325-**
13

Please contact factory for sizes not listed and for CS model
plastic sleeves for walls less than S.. thick.
* = Specify sleeve length in inches
** = Specify model when ordering

Page 2

LINK-SEAL
SIZE
LS-27 5-* *
LS-315-* *
LS-300-**
LS-315-**

LS-300-**
LS-315-**
LS-200-**
LS-300-**
LS-300-**

LINKS
PER

SEAL

4
4
4
5
5
6
9
8
10

Cell-Cast@Hole Forming Disks


Cell-Cas~ Hole Forming Disks are
designed to produce large diameter holes
in poured concrete structures. Molded
from HOPE plastic, Cell-Cast@
disks are lightweight and may be installed
by one construction worker. They are available
in a wide variety of opening diameters.
Disks are either 3" or 4" thick allowing one to form a hole in 3" walls
or thicker (except 5").
Features

()

Economy
Reduces material costs
8

by 30% to 50%.
8

Cuts labor costs by

50% - 70%.
8

Minimizes freight and

handling
Quality
8

charges.

Consistently produces
dimensionally
openings.

accurate

Sized to work with Link-SealModular Seals.


Avoids potential leak path between sleeve

and concrete.
Installation
8

Cell-Cast8 Hole Forming Disks


Model CC
Weights and Dimensional Data
HOLE
1.0.

3" THICKNESS
Ibs.
KG

((-30

29.25

100

4.53

4" THICKNESS
Ibs.
KG
10.4
4.71

((-32

31.13

10.8

4.89

11.2

5.08

((-36

34.75

12.6

5.71

13.1

5.94

((-38

3725

13.9

6.30

14.4

6.53

((-42

41.38

16.3

7.39

168

7.62
830

CElL-CAST"
MODEL NO.

Lightweight - 1/8 the weight of steel pipe


sleeves.

Complete assembly accomplished in


minutes.
Easilyinstalled by one construction worker.
Availability
.
Cell-Cas~ Disksare stocked in a variety of
diameters up to 64.75" (164cm) and
available for immediate delivery.
Larger sizes are available by special order
Flexibility
8

((-44

43.75

17.7

8.02

J83

((-48

47.25

20.0

907

20.7

9.38

((-50

50.00

22.0

9.97

22.6

10.25

((-54

5263

23.9

10.84

24.6

J I. 15
J2.38

Cell-Cas~ Disks are produced

in 3" and 4"

thicknesses and can be assembled to fit


virtuallyany wall.
For example:
Combine two 3" cells and one 4"
cell for 10" walls.

((-56

56.00

265

12.02

273

((-60

59.25

29.2

13.24

30.0

13.60

((-64

62.75

32.2

14.60

331

15.01

((-66

64.75

34.0

15.42

349

15.83

I
:J

Combine two 4" cells and one 3"


cell for 1 I" walls.
Combine three 4" cells for 12" walls.

.,I

fJ

Page 3

Cell-Cast@Disks and Link-Seal@Modular Seals Sizing Charts for Standard Pipe


Steel Pipe

t,
11

I'

~
1.(

PIPE
SIZE
(Nom.)
24
26
28
30
32
34
36
42
48
54
60

ACTUAL
O.D.
(Inches)
24.00
26.00
28.00
30.00
3200
34.00
36.00
42.00
48.00
54.00
60.00

HDPE Plastic Pipe


CELL-CAST
MODEL
NUMBER
((-30
((-32
((-32
((-36
((-38
((-38
((-42
((-48
((-54
((-60
((-66

* = SpecifY model when

ordering.

CAST
I.D.
(Inches)
29.25
3 J. J3
3 J. J3
3475
3725
37.25
4 J .38
47.25
52.63
59.25
64.75

LINK-SEAL
SIZE
LS-500-*
LS-500-*
LS-400-*
LS-525-*
LS-500-*
LS-400-*
LS-500-*
LS-500-*
LS-525-*
LS-500-*
LS-525-*

see Link-Seal@ modular

PIPE
SIZE
(Nom.)
24
26
28
30
800mm
32
34
36
1000mm
42
J200mm

LINKS
PER SEAL
21
23
25
26
28
30
3J
36
40
46
50

seal brochure.

ACTUAL CELL-CAST
O.D.
MODEL
(Inches)
NUMBER
24.00
((-30
26.00
((-32
28.00
((-32
30.00
((-36
3 J.50
((-36
32.00
((-38
34.00
((-38
36.00
((-42
39.37
((-44
42.00
((-48
47.24
((-54

54
54.00
((-60
* = SpecifY model when ordering,

CAST
I.D.
(Inches)
2925
3 J. J3
3 J. J3
34.75
34.75
37.25
37.25
41.38
43.75
47.25
52.63

LINK-SEAL
SIZE
LS-500-*
LS-500-*
LS-400-*
LS-525-*
LS-400-*
LS-500-*
LS-400-*
LS-500-*
LS-525-*
LS-500-*
LS-500-*

LINKS
PER SEAL
2J
23
25
26
28
28
30
3J
33
36
40

59.25
LS-500-*
46
see Link-Seal@ modular seal brochure.

Ductile or Cast Iron Pipe


PIPE
SIZE
(Nom.)
24
30
36
42
48
54

ACTUAL
O.D.
(Inches)
25.80
3200
38.30
44.50
50.80
5756

CELL-CAST
MODEL
NUMBER
((-32
((-38
((-44
((-50
((-56
((-64

* = SpecifY model when

ordering,

CAST
I.D.
(Inches)
31 13
3725
43.75
50.00
56.00
62.75

LINK-SEAL
SIZE
LS-500-*
LS-500-*
LS-500-*
LS-500-*
LS-500-*
LS-500-*

see Link-Seal@ modular

Concrete Pipe (ASTMB-WAll)

LINKS
PER SEAL
23
28
33
38
43
48

PIPE
SIZE
(Nom.)
21
24
27
30
36
42
48

seal brochure.

ACTUAL
O.D.
(Inches)
24.80
27.90

CELL-CAST
MODEL
NUMBER
((-32
((-36
((-38
((-42
((-48
((-56
((-64

* = SpecifY model when

PYC Plastic Pipe


PIPE
SIZE
(Nom.)
24
27

ACTUAL
O.D.
(Inches)
26.50
30.00
33.50
37.00
4400
5100
5800

CELL-CAST
MODEL
NUMBER
((-30
((-32

* = SpecifY model when

ordering,

CAST
I.D.
(Inches)
29.25
31. J3

LINK-SEAL
SIZE
LS-525-*
LS-400-*

see Link-Seal@ modular

ordering,

CAST
I.D.
(Inches)
3 J.13
34.75
37.25
41.38
47.25
56.00
62.75

LINK-SEAL
SIZE
LS-525-*
LS-525-*
LS-400-*
LS-525-*
LS-400-*
LS-500-*
LS-525-*

see Link-Seal@ modular

LINKS
PER SEAL
23
26
30
3J
39
43
49

seal brochure.

LINKS
PER SEAL
2J
25
seal brochure.

The system is the solution...use Century-Line@Sleeves or Cell-Cast@Disks with Link-Seal@


Modular Sleeves for a lifetime of leak-proof performance.
Features

Saves time and money...


Link-Sealmodular seals install in up to 75% less time compared to lead-oakum joints, hand fitted flC1shings,mastics or
casing boots.
Positive hydrostatic seal...
Link-Sealmodular seals are rated at 20 psig
(40 feet of head), which exceeds the
performance requirements of
most applications.
long seal life...
Link-Sealmodular seals are designed for use as
a permanent seal. Seal elements are specially compounded
to resist aging and attack from ozone, sunlight, water and a
wide range of chemicals.
Maximum protection against corrosion...
Standard hardware available
in zinc-dicromate with twopart proprietary organic
corrosion resistant coating or
corrosion resistant 3 I6
stainless steel.

Certification! Approvals...
Factory Mutual Fire Approvals. Det Norske Veritas Marine
Deck/Bulkhead Penetration Certification. ANI (American
Nuclear Insurers). Also a wide variety of approvals from
various Federal agencies, associations, code groups,
laboratories and organizations.
ISO Quality Assurance...
Link-Sealmodular seals
are manufactured in an ISO
9002 certified facility.
Configure a link-Seal
modular seal to match
your application...
Color coded EPDM, Nitrile, &
Silicone elastomers may be
used with various hardware
options to match performance characteristics with service
conditions. Visit our web site, www.linkseal.com, or see
Link-SealModular Seal Brochures for further details.

Page4

--

--

Installation Techniques - Century-Line@Sleeves


Century-Line@Sleeves are thermoplastic wall or floor pipe penetration sleeves. One person
working alone can usually install a Century-Line@Sleeve regardless of the size.

1. Measure the center line to


position Century-Line@Sleeve
end cap.

2. Nail one of the end caps at


the marked center line.

Always Wear Safety Equipment When Using


Century-Line Sleeves & Link-Seal Modular Seals!

5. For additional stability, its


necessary to secure the sleeve
with wire to the rebar Insert
the other end cap firmly and
check that second end cap is
positioned correctly and close
the form.

3. Place the Century-Line@


Sleeve on the end cap. The
sleeve should be cut 1/1" shorter than the width of the wall.
Cut with a hand or power saw.
Note: To insure minimum
water migration, center the
water stop in wall by cutting
equal lengths from each end of
the sleeve, except as noted
below.

4. Place second end cap on


sleeve. Check to determine that
the cap is properly inserted.
End
Cap
In"

Center
Water Stop

End
Cap
J"

~lrA~~B~lr
Always install Link-Seal
modular seals on side A

Wall

Cut From

Dimension

Thickness

Left End

0.0"
1.0"
2.0"
2S
2S

70"
60"
50"
4S
4S

16"
14"
12'"
10"
8"

6. After the concrete is poured


and cured, remove end caps
with screw driver or crow bar
End caps may be replaced to
protect sleeve until pipe penetration is made.

Cut From

Dimension

Right End
0.0"
1.0"
2.0"
3S
5.5"

B
70"
6.0"
5.0"
3S
IS

Notes:
I. Example: To convert
cut 2'" off each end.
Depression in face of the concrete formed by the endcaps.

Alternative Technique Using Threaded Rod

16" to 12'",

2. Endcaps leave 1/2'" depression


in face of concrete.
3. On sleeves under 12" length,
install Link-Seal@ modular seals on
the "long side" of the waterstop.
(a) For Link-Seal@ modular seals
models LS-200. LS-275. LS-300, LS315, LS-340 and LS-360- install

with pressure plates flush with


outer edge of the sleeve.
rb) For Link-Seal@ modular seals
models LS-325, LS-400, LS-410 \ LS-

..

425 and LS-475 - install with pressure plates partially inserted into
the sleeve. When tightened, the
pressure plates will "pull"' into the
sleeve

rc) For Link-Seal@ modular seals


models LS-500, LS-525, LS-575 and
LS-600 - the minimum sleeve

After nailing end cap to form,


drive (threaded rod*) through
the end plate and form and
(thread nut*) on other side.
Note: Remember to measure
the (threaded rod*) to match
the length of the sleeve.

Place the sleeve over the end


cap nailed to the form.
* = Not Provided

by PSI.

Place second cap on the sleeve


and use a (block of wood*)
and (wing nut*) to tighten unit
in place. Make certain sleeve is
plumb.

length is J0". Follow the instructions in #3 above.

Ifyou should have questions using


the instructions provided,
Call PSI at 713-747-6948 or
800-423-2410.

Page 5

- -. -

--

Installation Techniques - Cell-Cast@ Disks

1. Locate center line where the


hole is desired. This location
will be used as a guide for the
threaded centering assist rod.

2. A 2x4 wood nailer is included. Fasten it along with the


threaded rod directly to the
concrete form. This provides
support and helps center the
complete Cell-Cast@disk assembly.

3. Slide the first Cell-Castdisk


over the threaded rod.

4. Secure the edges of the cell


to the form using the provided
steel spikes.

5. Additional disks are interlocked to accommodate finished wall thickness. Verity


thickness is the same as wall.

6. Guide the 1" wood block


over the threaded rod and
secure the assembly with the
wing nut provided.

7. Wrap each seam with one


wrap of 2" wide tape to bridge
any possible gaps. Note: Tape
not included.

8. After wall cures, wall forms


are removed. The Cell-Castdisk
assembly is now ready for
removal.

n
Ifyou should have questions using
the instructions provided,
Call PSI at 713-747-6948 or
800-423-2410.

-.
9. Chip excess concrete from
the edge of the Cell-Cast disk
assembly and wall.

10. Remove disks by breaking


out the entire assembly.

11. Inspect the installation. A


smooth opening is important
for a proper Link-Seal@
modular seal installation.
Repair voids and grind
smooth any ridges.

Always Wear Safety Equipment When Using Cell-Cast@ Disks!

()

Page 6