Laboratory

Yenkay Instruments and Controls Pvt. Ltd., 128, Vinayak Society,


Sahakarnagar No. 1, Pune, Maharashtra
Location 1: 128, Vinayak Society, Sahakarnagar No. 1, Pune, Maharashtra
Location 2: Shop No. 38, Rajmata Industrial Premises, T-58, MIDC, Bhosari, Pune,
Maharashtra

Accreditation Standard ISO/IEC 17025:2005


Discipline

Thermal Calibration

Issue Date

22.04.2014

Certificate Number

C-0139

Valid Until

21.04.2016

Last Amended on

Page

1 of 2

Quantity Measured/
Instrument

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

Location: 2
I. TEMPERATURE
1.

RTD Sensors,
Thermocouple with or
without Indicator, Dig.
Thermometers, Data
Loggers with sensor,
Temperature Transmitter,
Temperature Bath#

-25C to 140C
140C to 350C

0.6C
0.7C

Using Isotech Venus,


Isotech Pegasus Temp.
Bath, Handy Calibrator
Multimeter, PRT Sensor,
RTD Sensor,
Data Logger with
Sensor & Thermocouple
(R & S Type)

2.

Glass Thermometers$

-25C to 140C

0.7C

Using Isotech Venus


Liquid Bath, Handy
Calibrator Multimeter,
PRT Sensor & RTD
Sensor

3.

All type of Thermocouples,


Dial Type Thermometers,
Dig. Thermometers,
Indicator with sensor
Thermistor Sensor with/
without Indicator, Data
Loggers with sensor,
Recorders with sensor,
Temperature Switch,
Temperature Transmitter#

0 to 140C
140C to 350C
350C to 600C
600C to 1000C
1000C to 1200C

0.7C
0.7C
1.7C
2.6C
3.0C

Using Isotech Venus,


Isotech Pegasus Temp.
Bath, Handy Calibrator
Multimeter, PRT Sensor,
RTD Sensor,
Data Logger with
Sensor & Thermocouple
(R & S Type)

Laboratory

Yenkay Instruments and Controls Pvt. Ltd., 128, Vinayak Society,


Sahakarnagar No. 1, Pune, Maharashtra
Location 1: 128, Vinayak Society, Sahakarnagar No. 1, Pune, Maharashtra
Location 2: Shop No. 38, Rajmata Industrial Premises, T-58, MIDC, Bhosari, Pune,
Maharashtra

Accreditation Standard ISO/IEC 17025:2005


Discipline

Thermal Calibration

Issue Date

22.04.2014

Certificate Number

C-0139

Valid Until

21.04.2016

Last Amended on

Page

2 of 2

Quantity Measured/
Instrument

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

Location: 2
4.

Infrared/Pyrometers, Laser
& Optical Pyrometers$

30C to 140C
140C to 250C
250C to 1000C
1000C to 1200C

0.7C
1C
2C
3C

Using Isotech Venus,


Isotech Pegasus Temp.
Bath & Black Body
Sources, Handy
Calibrator Multimeter,
PRT Sensor, RTD
Sensor & Thermocouple
(R & S Type)

5.

Thermal Chamber of
Ovens, Furnace,
Temperature Bath Heating
Cycle, Incubator,
Mapping, Temperature
Bath & any other
equipments
Multi point Calibration

25C to 350C
350C to 600C
600C to 1000C
1000C to 1200C

5.1C
6.3C
6.3C
6.3C

Using Handy Calibrator,


PRT Sensor, RTD
Sensor, Data Logger
with Sensor &
Thermocouple
(R ,S & K Type)

6.

Refrigerator/ Deep Freezers


Auto Claves, Cold
Chamber/ Environmental
Chamber
Multi point Calibration

-25C to 140C

4.5C

Using Handy Calibrator,


PRT Sensor, RTD
Sensor & Data Logger
with Sensor

* Measurement Capability is expressed as an uncertainty () at a confidence probability of 95%


$

Only in Permanent Laboratory


Only for Site Calibration
#
The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual
environmental conditions and master equipment used.