You are on page 1of 2

Minisonic PSD

GAS

APPLICATION

FULL
PIPE

P I G A ND SPHER E D ET ECTO R

MEDIA
MEASURED
LIQUIDS
& GASES

MODEL
STANDARD
PORTABLE

PIPE DIAMETERS
UP TO
1 500MM

EXPLOSION-PROOF
ENCLOSURE OPTION
AVAILABLE WITH
STANDARD MODEL

19 RACK OPTION
AVAILABLE WITH
STANDARD MODEL

SI M PL E

RELIABLE
AND ROBUST

HIGH
PERFORMANCE

MULTIPLE USES

Non-intrusive installation

Signal quality display

No process interruption

IP67 cast aluminium


enclosure

Detection of spheres
at up to 10m per sec

With any Pig Sig


model

Not aected by noisy


environments

COMPATIBLE

Intuitive operation

With any type


of liquid or gas*

External probes
(no contact with the
fluid, no loss of head)
Insertion probes
(increased head
possible)

 

 

TYPICAL APPLICATIONS

Hydrocarbons:
Detection of passing spheres
or pigs in pipelines

* APPLICATION CONDITIONS: PLEASE CONTACT US

EXPERT IN FLOW METERS


S I N C E 1 974

Minisonic PSD

NON CONTRACTUAL DOCUMENT

MOD E L

STAN DA RD

STA N DA R D

E X P LO S I O N P R O O F

P O RTA B L E

NATUR E OF EQUIPME NT

Fixed

D ETECTI ON I N P IPE
UND ER LOA D

Yes

FLOW MEASUREMENT
ON OPEN CHANNEL

No

EXTER NA L OF PIPE

100mm to 1500mm / 4 to 60

I NPU TS/OU TPUTS

2 static relay outputs

US E

Detection of the passing


of a sphere or pig

Detection in an explosive
environment of the passing
of a sphere or pig

Detection of the passing


of a sphere or pig

I N OP T I ON ,
2 U 1 9 R ACK

Available

S I NGL E OR D UA L PIPE

Single pipe

Single pipe

Single pipe

S I NGL E OR D UA L C HORD

Single chord

Single chord

Single chord

D I S PL AY

Alphanumeric (2 lines x 16 characters)


Backlit LCD screen with time delay feature

S ET-UP

Quick and simple using 4-key touch pad - or - via dedicated software supplied
Possible to build in an access code

OPER ATI NG SYST E M

Windows for set-up and saving application data

6 L A NGUAGES

)UHQFK(QJOLVK*HUPDQ3RUWXJXHVH6SDQLVK,WDOLDQ

S ER I A L L I NK

56RU56WR-%8602'%86SURWRFRO%DXGV

ACCES S OR Y ( OP T IONAL)

1 RS232 to USB converter link cable

EL ECTR I CA L
CH A R ACTER I STIC S

2 Static relays (100V - 100mA - 10VA max)


1 RS232/RS485 serial link to MODBUS/JBUS protocol

2 Static relays
(100V - 100mA - 10VA max)
1 RS232 serial link to
MODBUS/JBUS protocol

%DVLFSRZHUVXSSO\/RZYROWDJH9GFRU9DF
2SWLRQDOSRZHUVXSSO\9GFRU9DF
2 current outputs, 4-20mA (1000 galvanically isolated
as passive output/150 impedance as an active output)

12V NiMh sealed internal


battery
100-240V ac charger and
aux. power supply function
2 active current outputs,
4-20mA (150 impedance)

ENCLOS UR E

Cast aluminium & epoxy paint


 NJ[[PP

Cast aluminium & epoxy paint


 NJ[[PP

$ %66XSSOLHGZLWKDVOLS
case and storage bag
 J[[PP

PR OTECTI ON

,3 H[FHSWUDFN )

,3

TEMPER ATUR E RANGE

For use from 0C to 50C

TE CHNOLO GY

PER FOR M A N CES

ULTRASONIC TRANSIT
TIME

ACCURACY

LINEARITY

Up to 0.5%

Up to 0.1%

REPEATABILITY

UNITS OF MEASUREMENT

Up to 0.1%

Metres per sec.

Portable

RS232 to JBUS/MODBUS
SURWRFRO%DXGV

Continuous measurement
SIGNAL ANALYSIS

By Echo Shape Control


(optimisation of
the acoustic signal)

EXPERT IN FLOW METERS


S I N C E 1 974

You might also like