You are on page 1of 2

Timer Start

T300

Transmission of
RRCConnectionRequest

Stop

At expiry

Reception of RRCConnectionSetup
or RRCConnectionReject message,
Perform the
cell re-selection and upon abortion
actions
of connection establishment by
upper layers

Reception of
Transmission of
RRCConnectionReestablishment or
Go to
T301 RRCConnectionReestabilshmentRequ RRCConnectionReestablishmentRej
RRC_IDLE
est
ect message as well as when the
selected cell becomes unsuitable
Inform upper
Access barred while performing RRC
layers about
Upon entering RRC_CONNECTED
T303 connection establishment for mobile
barring
and upon cell re-selection
originating calls
alleviation as
specified

Reception of
RRCConnectionReconfiguration
message including the
T304
MobilityControl Info or reception of
MobilityFromEUTRACommand
message including CellChangeOrder

In case of
cell change
order from EUTRA or
intra EUTRA
handover,
initiate the
RRC
Criterion for successful completion connection
of handover to EUTRA or cell
rechange order is met (the criterion is establishment
specified in the target RAT in case of procedure; In
inter-RAT)
case of
handover to
E-UTRA,
perform the
actions
defined in the
specifications
applicable for
the source
RAT.

Inform upper
Access barred while performing RRC
layers about
Upon entering RRC_CONNECTED
T305 connection establishment for mobile
barring
and upon cell re-selection
originating signalling
alleviation as
specified

Upon detecting physical layer


problems i.e. upon receiving N310
T310
consecutive out-of-sync indications
from lower layers

T311

Upon initiating the RRC connection


re-establishment procedure

If security is
not activated:
Upon receiving N311 consecutive
go to
in-sync indications from lower
RRC_IDLE
layers, upon triggering the handover else: initiate
procedure and upon initiating the
the
connection re-establishment
connection
procedure
reestablishment
procedure
Selection of a suitable E-UTRA cell Enter
or a cell using another RAT.
RRC_IDLE

Upon entering RRC_CONNECTED,


Upon receiving t320 or upon cell
when PLMN selection is performed
(re)selection to E-UTRA from another
on request by NAS, or upon cell
T320 RAT with validity time configured for
(re)selection to another RAT (in
dedicated priorities (in which case the
which case the timer is carried on to
remaining validity time is applied).
the other RAT).

Discard the
cell
reselection
priority
information
provided by
dedicated
signalling.

Initiate the
measurement
reporting
Upon acquiring the information
procedure,
needed to set all fields of
stop
Upon receiving measConfig including
globalCellId for the requested cell, performing
T321 a reportConfig with the purpose set to
upon receiving measConfig that
the related
reportCGI
includes removal of the reportConfig measurement
with the purpose set to reportCGI
s and remove
the
correspondin
g measId

You might also like