You are on page 1of 2

PhaseTester Vx Services

PhaseTester portable multiphase periodic


well testing equipment is designed for easy
deployment. This solution-oriented service
covers the entire testing process from
design to reservoir interpretation.
Schlumberger offers service components
to match the needs of the job, including
site-specific safety analysis, wellsite
operations, well test reporting, well data
analysis and production diagnosis. With
minimal footprint and on-site installation

PhaseTester* Vx portable multiphase meter

needs, the PhaseTester service reduces the


cost per well tested through efficiency and
simplified logistics. The PhaseTester Vx*
multiphase well testing units have excellent
dynamic response to well flows and
require little or no stabilization time. As
many as three wells per day can be tested
on a typical production station.

Applications
Production well testing
Production allocation
Production trends
Gas lift optimization
Well cleanup optimization
Exploration and appraisal
testing
Benefits
Quicker, more efficient well
testing
Reduced field development
costs
Early water detection
Improved well diagnostics
Reduced rig-time costs
Eliminated test lines
Improved installation and
operation safety
Reduced gas flaring
Features
Repeatable, highly accurate
measurements
Low volume and rapid
stabilization for exceptional
dynamic response
No separation required
Slug, foam and emulsion flow
measurements are not ordinary

Specifications
Vx 52 mm

Vx 29 mm

Venturi size

52 mm

29 mm

Service

H2S (wetted parts)

H2S (wetted parts)

Max. working pressure (psi [kPa])

5,000 [34,475]

5,000 [34,475]

Temperature rating (F [C])

4 to 302 [20 to 150]

4 to 302 [20 to 150]

Ambient working temperature (F [C])

4 to 185 [20 to 85]

4 to 185 [20 to 85]

Ambient storage temperature (F [C])

40 to 185 [40 to 85]

40 to 185 [40 to 85]

Water-liquid ratio

0 to 100%

0 to 100%

Liquid viscosity

0.1 to 2000 cp at line conditions

0.1 to 500 cp at line conditions

Maximum flow capacity

Liquid flow rate: 39,500 aB/D


Gas flow rate: 0.57 MMacf/D

12,900 aB/D
0.17 Mmacf/D

Uncertainty

Function of the operating conditions; estimated up to 98% of the gas volume fraction using proprietary Vx Advisor
software

Repeatability

1% (total mass rate)

1% (total mass rate)

Resolution

0.1% (total mass rate)

0.1% (total mass rate)

Dimensions (W D H) (ft [m])

4.92 5.41 5.81 [1.50 1.65 1.77 ]

4.92 5.41 5.81 [1.50 1.65 1.77 ]

Weight (lbm [kg])

3750 [1700 ]

3750 [1700]]

Connections

Inlet blind tee with 5-in. GRAYLOC hub


Outlet with 5-in. GRAYLOC hub

Inlet blind tee with 5-in. GRAYLOC hub


Outlet with 5-in. GRAYLOC hub

Power consumption

25 W continuous

25 W continuous

Certification for explosion-proof equipment

CENELEC EEx d IIB T4

CENELEC EEx d IIB T4

Ingress protection (IP)

IP 67

IP 67

Communication

2 RS 422 Modbus protocol (service computer and spare are SCADA compatible)
Web interface (option): InterACT* remote communications software
Combinable with Schlumberger production logging tools gas volume fraction using proprietary Vx software

Client pressure-volume-temperature (PVT)

Client PVT model computation of flow rates from (option) line conditions to standard conditions

Sampling ports

Liquid and gas sampling facilities

Maximum liquid capacity at gas-liquid ratio (GLR) = 0, liquid density = 850 kg/m3, pressure = 300 psia, WLR = 0 and
venturi differential pressure (DPV) = 5 bar.
Maximum gas capacity at GLR = 10, gas density = 25 kg/m3, pressure = 300 psia and DPV= 5 bar.
Supervisory control and data acquisition.
European-approved explosion-proof equipment.

www.slb.com/oilfield
WT_00_039_0

Schlumberger

September 2003

*Mark of Schlumberger

GRAYLOC is a registered trademark of Yellowstone Energy Products, Houston, TX.

Liquid and gas sampling facilities