Professional Documents
Culture Documents
The orifice plate is used in many fluid systems to detect and measure the amount of
flow of a fluid moving through piping in various systems. They are relatively
inexpensive, and provide adequate accuracy for most applications. Understanding the
flow dynamics involved is an important and sometimes confusing part. (From an
engineering stand point.) This paper is for those Engineers or students who wish to get a
better understanding of the orifice plate and the calculations that go along with it.
In order to solve for the data to be used in the construction, calibration of sensing
equipment, and passing an engineering exam, an understanding of the system and terms
of the flow formulas must be analyzed. See drawing one below for a typical installation
and features of an orifice plate flow device.
Pressure taps P1 P2
∆P = P1 - P2
Orifice plate
Before we derive the first equation, let's define some terms and talk about some
problems in theory regarding orifice plates. First, the term Cd (Discharge coefficient)
used in equations is related to the flow characteristics through the actual orifice device.
Commonly you will see this term described as the ratio of the orifice aperture diameter to
the diameter of the pipe. This ratio is often referred to as the β (beta) ratio, but we are still
talking about the Cd.
𝑂𝑟𝑖𝑓𝑖𝑐𝑒 𝑑𝑖𝑎
β= = Cd
𝑃𝑖𝑝𝑒 𝑑𝑖𝑎
Having said that however, there are other factors involved in the actual evaluation of
what the exact values are. These are the shape of the orifice aperture, the Reynolds
number, the vena contracta which is related to the shape, density changes, expansion
coefficient, operating temperature, and the actual ∆P of the orifice. We will explore these
later on in the discussion. The vena contracta is essentially the area after the orifice where
the pressure drop is at maximum and the point where you might consider placing the low
pressure tap. There are many different ways to obtain the desired characteristics of the
delta P and there are different equations that are also used to describe the flow rate. The
one I am going to derive is one of the common ones but by all means is not the only one.
The industry is trying to come up with one standard equation to describe the theoretical
flow through an orifice, but to my knowledge, that has not happened yet. Until then, it
will be up to the engineer to decide his own program for determining flow rates and
determining what type of orifice plate configuration to use.
𝑃1 𝑉12 𝑃2 𝑉22
+ + ℊ Z1 = + + ℊ Z2 Where: P1 = Pressure at inlet to orifice
𝜌 2 𝜌 2
P2 = Pressure at orifice @ Vena contracta, V1 = Velocity before the orifice
V2 = Velocity at vena contracta, 𝜌 = rho, density of what you are pumping, ℊ =
gravitational constant
Since the heights are the same, (orifice plates are installed on straight runs of horizontal
pipe) ℊ and Z can be ignored.
𝑃1 𝑉12 𝑃2 𝑉22
So then: + = + Rearranging terms gives
𝜌 2 𝜌 2
2(𝑃1 −𝑃2 )
+ 𝑉12 = 𝑉22 Rearranging
𝜌
2(𝑃1 −𝑃2 )
𝑉22 = 𝑉12 +
𝜌
Since A1 V1 = A2 V2 (Continuity equation) I can rewrite V1 in terms of V2
𝐴2
V1 = 𝑉2 Now, squaring both sides
𝐴1
𝐴2 2
𝑉12 = x 𝑉22 Next, I am going to substitute these terms back in for 𝑉12
𝐴1
𝐴2 2 2(𝑃1− 𝑃2 )
𝑉22 = x 𝑉22 + Dividing both sides by 𝑉22
𝐴1 𝜌
𝐴2 2 1 2(𝑃1− 𝑃2 )
1= + x Subtracting the area term from both sides
𝐴1 𝑉22 𝜌
𝐴2 2 1 2(𝑃1− 𝑃2 )
1- = Multiplying both sides by 𝑉22
𝐴1 𝑉22 𝜌
𝐴2 2 2(𝑃1− 𝑃2
𝑉22 1− = Dividing both sides by the area terms.
𝐴1 𝜌
1 2 (𝑃1 − 𝑃2
𝑉22 = 2 Taking the square of both sides.
1−
𝐴2 𝜌
𝐴1
1 2(𝑃1 − 𝑃2 )
𝑉2 = Converting to flow instead of velocity.
𝐴2 2 𝜌
1−
𝐴1
𝐴2 2( ∆𝑃)
Q= 2
Adding in the discharge coefficient for the orifice plate.
𝐴2 𝜌
1−
𝐴1
𝐶𝑑 𝐴 2 2(∆𝑃)
Q=
𝐴2 2 𝜌
1−
𝐴1
This is one of the equations you will see in text books and on the internet for orifice
plates. Notice that the equation in this form does not have any time consideration on the
right hand side of the equation. This is an expression, and must be modified to calculate
flow. The equation can be modified to get answers in flow by understanding what Q is.
𝐶𝑑 𝐴 2 2(∆𝑃)
Q= 2𝑔 because ≈ 2𝑔
𝐴2 2 𝜌
1−
𝐴1
Here is an example: Say you have a 4 inch pipe and an orifice which has a Cd of .6
and a reading of 120 inches head. What is the flow rate in gpm?
𝐶𝑑 𝐴 2
Q= 2𝑔 D1 = 4.026 (Nominal 4"pipe) D2 = .6 x 4.026 = 2.416
𝐴2 2
1−
𝐴1
inch. A1 = 𝜋𝑟 2 = 3.1416 x 4.05 = 12.723 inch2
.6 𝑥 .03165 𝑓𝑡 2 𝑓𝑡 𝑓𝑡 3 𝑔𝑎𝑙
Q= x 25.3 = .5166 ≈ 231.87
.93 𝑠𝑒𝑐 𝑠𝑒𝑐 𝑚𝑖𝑛
𝑓𝑡 3
Remember, converting to Gpm is accomplished by multiplying that number by
𝑠𝑒𝑐
448.83. Also to convert ∆𝑃 to feet head is done by multiplying by 2.311, or to inches
head by 27.73 at STP. Now, go on the internet and find Daniel orifice flow calculator and
download the free program for calculating flow. Once you have done that select flow,
density of water is 62.4 lb/ft3, and plug in the pipe size and Cd given in the example. You
should come up with 233 gpm. You can use this program to approximate any flow
condition that you like and determine orifice size or whatever.
Here are some other formulas that have been derived or experimentally determined that
lead us to the same set of information only different as to how we get there.
C = discharge coefficient Cd
e = expansion coefficient
1
E=
𝐷2 4
1−
𝐷1
Note: This equation must also be converted to account for time on the right hand side,
just like we did for the first one. That is if you want to calculate a flow in GPM.
Here is an interesting equation that comes from a manufacturer of orifice plates
𝑔
𝑐𝑜𝑛𝑠𝑡𝑎𝑛𝑡 𝑑 2 𝐶 𝑌 𝐹𝑎 𝑤
𝑔0
Q= where: Q = flow rate
1−𝛽 4 𝜌1
this you dont have worry about the time factor in the equation as the other two
C = discharge coefficient
Y = expansion factor
𝐷2
β = Cd or beta ratio
𝐷1
Remember in all of this, the Idea is to get a good approximation of the flow through
the system, as that is the reason for putting in an orifice, right? So these equations can be
used to suit your needs as an engineer. You can also include the Reynolds number if you
want in the Cd figure or if you want you can include a flow coefficient to account for the
Reynolds number and expansion coefficient. It's really up to you, the engineer. I hope this
helped you out understanding the confusion over orifice plate calculations and how
complicated it can be. But you as the engineer must determine what best suits your needs.
As for students that are just trying to figure things out, use the first equation I gave you to
calculate flow through an orifice, it will be close enough for you to understand what's
happening.