GE

Transportation
Mining

CTRLPSB32
IGBT PHASE
FUSE
PART NUMBER
CHANGE
Murtada B. Tunis

These instructions do not purport to cover all details or variations in equipment or to provide for every possible contingency to be met in connection with
installation, operation, or maintenance. Should further information be desired, or should particular problems arise which are not covered sufficiently for the
users purposes, the matter should be referred to GE. An applicable Federal, State, local regulations or company safety or operating rules must take
precedence over any instructions given in this material. GE has no obligation to keep the material up-to-date after the original publication.

THERE ARE NO WARRANTIES OF ACCURACY, MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE.

ACPSB32 Rev. 0

Nov.-07, 2007

Murtada B. Tunis

Page 1 / 4

Section

Content

Page

Purpose

II

Background

III

Type P1: The original 600A types

IV

Type P2: The New 300A model

Type P3

VI

Frequently Asked Questions (FAQs)

ACPSB32 Rev. 0

Nov.-07, 2007

Murtada B. Tunis

Page 2 / 4

I.

Purpose:

This service bulletin is designed to clarify the part number changes that have taken place with the
IGBT Phase Fuses. The goal is to ensure that the correct part numbers are ordered in the correct
quantities and to explain the apparent changes in rating identification on the fuses.

II.

Background:

The phase fuses connect the positive side of the DC Link to the IGBT side of the phase module. They
serve to isolate an inverter phase after a short circuit failure.

III.

Type P1: The original 600A types

Originally, there was IGBT Phase fuse 41A296321BSP1. This fuse came as a pair of two in parallel
with each other with a legibly marked current rating of 600amps. If for any reason one of the P1
types is replaced, they must be replaced as a matched pair.

IV.

Type P2: The New 300A type

The original 41A296321BSP1 fuse pair has been superseded by two of 41A296321BSP2 IGBT fuses.
This fuse, 41A296321BSP2, is a single fuse that is legibly marked with a current rating of 300amps.
The new requirement is that a quantity two 41A296321BSP2 should replace one 41A296321BSP1.
The new 41A296321BSP2s are controlled so that the need to have matched pairs is no longer
required. Additionally, a pair of these 41A296321BSP2s can be applied to an inverter phase even if
other phases of that inverter have the 41A296321BSP1 type fuses. If, however, for any reason one of
the P2s 300 amp fuses is blown, they must be removed as a pair as in P1 above.

V.

Type P3

A new part number was also developed, 41A296321BSP3, to supersede the 41A296321BSP1. When
ordering 41A296321BSP3, you will receive quantity two of 41A296321BSP2 fuses.

ACPSB32 Rev. 0

Nov.-07, 2007

Murtada B. Tunis

Page 3 / 4

VI.

Frequently Asked Questions (FAQs)

The explanation above has been summarized in an FAQ below.

Can 300amp (BSP2) pairs of fuses be used in an inverter phase when other
phases have 600amp (BSP1)?

A pair of 41A296321BSP2 fuses can be applied on an inverter phase even if


other phases of that inverter have 41A296321BSP1 fuses.

Can one replace a single blown 600A fuse of the type P1 only?

In the unlikely event that only a single fuse blows out of a fuse pair, both fuses
should be replaced regardless of whether the fuses are 41A296321BSP1 or

Can a 300A BSP1 be mixed in the same phase as a 600A?

No. The 300A and the 600A fuse should not be mixed in one phase.

?
A

Since two BSP2 Fuses replace each BSP1 Fuse, is it advisable to therefore
double BOM on these parts?
Yes.

Since the BSP1 was superseded to the BSP3, which in turn was superseded to
the BSP2, does that mean the BSP3 cannot be ordered?

The BSP3 is still a real part and is orderable. 41A296321BSP3 simply calls for
quantity 2 of 41A296321BSP2 fuses.

ACPSB32 Rev. 0

Nov.-07, 2007

Murtada B. Tunis

Page 4 / 4