You are on page 1of 56

Digital Control System for Electrical application

PACiS

Alain Roux
South Europe Sales Manager
Bogdan Ianculescu
Commercial Manager Romania

Sibiu, May 2009

PACiS Application markets


UTILITIES
SUBSTATIONS

DISTRIBUTED
GENERATION

> PACiS short EN 20/05/08- Issue H

INDUSTRIAL
PLANTS

INFRASTRUCTURES

PACiS : First IEC61850 Solution

More than 509 PACiS since 2002

2002 PACiS projects

2004 PACiS projects

2006 PACiS projects

2003 PACiS projects

2005 PACiS projects

2007 PACiS projects

> PACiS short EN 20/05/08- Issue H

2008 PACiS projects

PACiS Application Areas

300 V up
to 800 kV
GREEN FIELD
& RETROFIT

FAST LOAD SHEDDING,


VOLTAGE REGULATION,
SYNCHRO-CHECK

AREVA TURNKEY
& LOOSE DELIVERY

AIS & GIS


INDOOR
& OUTDOOR
5

> PACiS short EN 20/05/08- Issue H

Introducing PACiS: Concepts


SCALABLE SOLUTION

Scope, Functions, Architecture, Engineering

HIGH STANDARDIZATION
LEVEL
Communication, Bay/Substation,
Services

> PACiS short EN 20/05/08- Issue H

DEDICATED TO
POWER AUTOMATION

Security, Topological automation,


Smooth evolutions, Outage optimization

PACiS: A scalable solution


SCOPE
Network

M+C+P+

Site

Power

Substation

Management
M+C+

Voltage level

Protection

Busbar

M + Control

Bay

FUNCTIONS

> PACiS short EN 20/05/08- Issue H

Monitoring

High standardization level

Communications
IEC 61850, IEC60870-5-101,103, 104,
DNP3 & DNP3/IP, MODBUS

Automation Schemes
IEC 61131-3

Engineering & Service


Lifetime Cost & Lead Time optimization
8

> PACiS short EN 20/05/08- Issue H

Introducing PACiS: Components


IEDs

Protections, Computers, Measurement

SOFTWARE

Engineering tools, SCADA

> PACiS short EN 20/05/08- Issue H

COMMUNICATION
Switches, Gateways

AN UNRIVALED IEDs BASIS

MiCOM A300 : Solid State PC


MiCOM C264/C264P: Bay Computer, RTU,
Feeder Protection, Automatic Voltage Regulator
MiCOM Hxxx: Manageable Ethernet Switchs
MiCOM Mxxx: Measurement & Disturbance
Recorders
MiCOM Pxxx: Protection Relays
MiCOM Txxx: Telecoms units
10

> PACiS short EN 20/05/08- Issue H

10

MiCOM A300 : PACiS GATEWAYS


Ensure data exchange with the EMS
Serial and Ethernet ports
Integrated Ethernet switch
Hot stand-by redundancy
Fully configured within PACiS SCE
PC base solution
without rotating part (XPe)
Fully compliant with Electrical
installation constraints
(IEC 60255 & IEC 1004)

Give the right information to the process


11

> PACiS short EN 20/05/08- Issue H

11

MiCOM Hxx MANAGEABLE ETHERNET SWITCHES


Complete MiCOM H range
All Ethernet network architecture
Star,
Redundant ring
Dual attachment

SNMP management features


Single and multi-mode 10/100 Mbps
DIN- rail case with redundant
power supply 24/48/60/110/220 Vcc
Fully compliant with Electrical
installation constraints (IEC 60255 & IEC 1004)
Also as a PCI board (PC integration) or board for C264

Benefit from the protection relay world reliability


12

> PACiS short EN 20/05/08- Issue H

12

MiCOM C264: The Bay Computer


Bay controller
IEDs gateway
RTU/Gateway
Data Concentrator
PLC
MV Feeder Protection
SER Events recorder
Waveform/Disturbance
recorder
Automatic Voltage
Regulator
Ethernet switch
MiCOM C264 modular bay computer has
the same design as the MiCOM relay series.
13

> PACiS short EN 20/05/08- Issue H

13

MiCOM C264 Communications


Up to 6 Ethernet Ports FX or TX
Single star
Redundant ring
Dual star (double attachment)
SCADA communication :IEC 61850
Server, IEC 60870-5-104, DNP3.0
Level 3/TCP, MODBUS RTU/TCP
IED communication :IEC 61850 Client

Up to 4 Serial Communication Ports


(Master or Slave Selectable)
SCADA communication :IEC 60870-5101, DNP3.0 Level 3, MODBUS RTU,
HNZ
IED legacy communication :IEC
60870-5-103, Modbus RTU, IEC 608705-101, DNP3.0 Level 2
Local Event printer
14

> PACiS short EN 20/05/08- Issue H

14

MiCOM C264P : MV Feeder protection


Busbar
1 Phase BB VT

52

Trip

Phase
CTs
Earth CT
3 Phases
VTs

MiCOM C264-P
59N

37

67

50N
51N

67N

50
BF

81R

32N

27

46

50
51

59

Logic inputs
79

81O

Logic outputs
81U
Analog inputs
Analog outputs

RS 485
/RS232/
RS422

IEC61850
Legacy comm.

IEC 61850 MV Feeder OBS


1 ms time tagging
Dedicated Protection CPU
IED Data Concentrator
PLC IEC61131-3
SER Events recorder
Disturbance
recorder
Embedded Ethernet switch

MiCOM C264P MV OBS has the same IOs boards


as the MiCOM C264
15

> PACiS short EN 20/05/08- Issue H

15

Network monitoring solution


70 series: M871, M872 (modular) M571, M572 (compact)
Recording
Disturbance
Trend
Power Quality
Measures
Transducer
SCADA interface

Analysis and management software

Database records management, record analysis, report generation.

16

> PACiS short EN 20/05/08- Issue H

16

Measurement Centres
Measurement Centres. M2x3 Range
MiCOM M233 Basic Measurement centre
MMC

Measures
Tariff registers
Digital display

MiCOM M243 and M253 : Measurement Centre with embedded

limited recording functions.

Measures
MMC

Tariff register
Recording
Digital and graphic display

17

> PACiS short EN 20/05/08- Issue H

17

MiCOM P portfolio
P900

Frequency Protection Relay

P800

Autoreclose Relays

P700

Busbar Protection Relays

P600

Transformer Protection

P500

Line Differential Relays

P400

Distance Protection Relays

P300

Generator Protection Relay

P200

Universal Motor Protection

P100

Feeder Management Relays

Generation
18

Transmission

> PACiS short EN 20/05/08- Issue H

Distribution

Indep.producer
18

MiCOM Relays
Generation

P340

Transmission

P630

P139 P940 P920


P120 P140 P340

P740 P440 P540 P140

P220

P630
P120
Home

P240

Industry

P630

P210

P140
P130

Distribution
Low Voltage

P110
MiCOM realys cover all areas of the power system
19

> PACiS short EN 20/05/08- Issue H

19

MiCOM Relays
Hardware & Software Platform
Feeder Motor Generator Distance

61850

P 14x

61850

P 24x

P 34x

P 13x
61850

20

B.B. Transf.
Diff.
Diff.

61850

P 44x

P 54x P 74x P 64x P 94x P 84x

P 43x

P 63x

61850

P 22x
P 22x

> PACiS short EN 20/05/08- Issue H

Freq CBF

61850

P 52x P 72x

Px20

P 12x

61850

I
Diff.

P 92x P 82x

20

MiCOM Telecom Solutions


Universal Power Line carrier MiCOM T390
Multiplexers, Tele-protections DCX5000, DIP 5000
Telecom Management system
RTU
distance protection
Differential protection

Teleprotection

PLC T390

Teleprotection

RTU
distance protection
Differential protection
Ethernet Subs
bus

Ethernet Subs
bus

SDH

Telecom Management

21

> PACiS short EN 20/05/08- Issue H

MUX

MUX

21

Introducing PACiS: Components


IEDs

Protections, Computers, Measurement

SOFTWARE

Engineering tools, SCADA

22

> PACiS short EN 20/05/08- Issue H

COMMUNICATION
Switches, Gateways

22

PACiS software

Local Human Machine Interface :


PACiS OI single or redundant servers
Up to 8 PACiS OI local or remote clients

Engineering tools :
System Configurator Editor : PACiS SCE
System Maintenance Tools : PACiS SMT
MiCOM C264 Remote Maintenance C264 WEB Server
MiCOM S1 C264P Protection parameters

23

> PACiS short EN 20/05/08- Issue H

23

PACiS HMI :Advanced SCADA features


Substation screens
Control & Command
Primary equipments
Alarm & Event viewer
Measurements
Trend viewer
Video inclusion

Alarm windows
Most recent
alarms
Nature, Status,
Severity, Time
stamping 1 ms
Up to 6 different
Alarm levels

Up to 8 independent PACiS users


WEB access for remote control
Complete redundancy
24

> PACiS short EN 20/05/08- Issue H

24

PACiS HMI : Alarm/State/Event browsers

Event list
1ms datation
Customisable
Colors indication
Event sorter
Logic
condition
Name
Date or time
Device
Bay
Events browser
Voltage level
Tree
presentation
Event per
device
Icon
identification

25

> PACiS short EN 20/05/08- Issue H

25

PACiS Engineering tools

System Configurator Editor - PACiS SCE


System Management Tool - PACiS SMT
C264 Remote Maintenance C264 WEB Server
MiCOM S1 C264P Protection parameters

Simplify and Secure Customer engineering


26

> PACiS short EN 20/05/08- Issue H

26

PACiS System Configurator Editor Objectives


DATA CONSITENCY:
between domains (communication, HMI, graphical, automation, etc.)
between devices (HMI, gateway, bay computer, protections, etc)

LARGE DATA FLOWS:


More data than with legacy communication protocols
More flows (client/servers, peer-to-peer), not only master slave

EASE OF USE
Implicit processing (data, logic)
No need to be an IEC 61850 expert

LIFE CYCLE APPROACH


Manage evolutions during the system life
Handle legacy devices

An essential tool for modern Substation Automation Systems


27

> PACiS short EN 20/05/08- Issue H

27

PACiS SCE : Data consistency

EDITORS
Object oriented with hierarchical domain approach in line with IEC 61850 hierarchy

4 Domains in 1 Tool
Electrical Part
System Part
Graphical Part
Automation Part

Key features
Create/Delete Relations
(bindings) between domains
Template management (per
domain and composite)
Check per editor and global
(completion, consistency)

A single tool
28

> PACiS short EN 20/05/08- Issue H

28

PACiS SCE : Large volume of data handling


Graphical template example
Evolution

TEMPLATES
Instances
A template can be made of
Graphical, Electrical, System and
Automation domains.
It might be imported (typ. An IED)

Automatic

CB1

CB2

CB3

CB1
CB2
CB3

QUERIES
Database on
Multiple criteria

Industrial approach
29

> PACiS short EN 20/05/08- Issue H

29

PACiS System Management Tool


System Management Tool functions:
Management Configuration database download
to PACiS equipment (HMI, IEDs)
Ensure coherency between the Configuration
Databases
Store the Configuration Database versions
Allows upload of Waveform/Disturbance records

30

> PACiS short EN 20/05/08- Issue H

30

MiCOM C264 Maintenance Web Server


Access from Internet Browser
(Mozilla Fox or IE) with user +
password
Visualisation of Bay
Maintenance data :
MiCOM C264 Hard & Soft Status,
I/O status,
Sequence of 2 000 Time stamped
stored Events,
Instantaneous reports (Measures,
Counters, Binary Inputs, Status
list)
Legacy IEDs status
31

> PACiS short EN 20/05/08- Issue H

31

MiCOM S1 - MiCOM Protection setting software


Upload and download of MiCOM C & P protection parameters
On-line and Off-line modification of the models
Connection
via the Ethernet network
Available in various languages:
English,
French,
Spanish
German

32

> PACiS short EN 20/05/08- Issue H

32

PACiS Automation schemes


Pre-designed automation schemes
MiCOM C264 level
Automatic Voltage Regulator
Synchro-check
Autorecloser
PACiS application level
Fast Load shedding for Large industry and Oil & Gaz
Interlocking

Personnalized automation schemes


Using the IEC61850 GOOSE peer-to-peer fast data
transfert capabilities
Programmable Scheme Logic
IEC61131-3 automatism language (ISAGRAF)
33

> PACiS short EN 20/05/08- Issue H

33

MiCOM C264 Built-In Automation


PLC applications - Build in sequences
Built-in Functions : embedded and validated
Autorecloser
For feeder control
up to 4 cycles , 1PH + 3PH, with Interlock checks
parameters adaptable on the local LCD screen

Synchronised CB Management (SynchroCheck)


for Generator connection, or between 2 networks
Customised criterias : Phase Angle, Frequency,
magnitude
parameters adaptable on the local LCD screen

Automatic Voltage Regulation


up to 4 transfos in // , manage up to 7 transfos
Tap changer - Raise / Lower
In association with others C264 interfaced on the
station Bus -IEC61850
Compounding line drop compensation
Circulating Current minimisation
// Master/Follower
34

> PACiS short EN 20/05/08- Issue H

34

MiCOM C264 Customised Automation


PLC applications

For various applications :


Switching sequences,
Busbar transfer,
Load management, (slow)
GIS pressure supervision
Capacitor Bank management

IEC61131-3 languages
Structured Text (ST)
SFC (Grafcet)

Large capability to evaluate


Analog values
Digital values

35

> PACiS short EN 20/05/08- Issue H

In complement of the fast PSL


facilities (Programming Scheme
Logic)

35

PACiS Fast Load Shedding


OVERALL
PROCESS CONTROL

The Fast load shedding has it own dedicated


network connected to the main PMS
application
Permanently recalculate the shedding
priorities based on the real topology, power
available and necessary loads
Take in account the network constraints
Transformer capabilities
Generator spinning reserve

In case of a sudden generator fault or grid


weakness
Trip directly the less prior elements
Recalculate the total network availability

Load sharing (active and reactive) between


generators
Generation

36

Load

> PACiS short EN 20/05/08- Issue H

Islanding and reconnection (including


synchronization)
36

Ring Network Automatic reconfiguration


4 : RECLOSING OF THE
INCOMING FEEDER
DELIVERY SUBSTATION
2 : TRIPPING OF :
FEEDER 1

FEEDER 2

1 : THE FAULT IS SEEN :

M
SUBSTATION D
M

SUBSTATION A

3 : ISOLATION OF THE FAULTY


SECTION BY OPENING:

FAULT

M
SUBSTATION C
M

SUBSTATION B

STANDARD OPEN POINT OF THE RING


5 : RECLOSING OF THE OPEN POINT OF THE
RING

37

> PACiS short EN 20/05/08- Issue H

37

Introducing PACiS: Components


IEDs

Protections, Computers, Measurement

SOFTWARE

Engineering tools, SCADA

38

> PACiS short EN 20/05/08- Issue H

COMMUNICATION
Switches, Gateways

38

Ethernet Architecture : Redundant ring

PACiS GATEWAYS

PACiS OI

Up to 4 TX links

Substation Level

MiCOM H152 PCI board


located in one PC

MiCOM H352
Din Case

Ethernet - up
to 6 links

Ethernet - up
to 4 links
Bay Type 4

39

> PACiS short EN 20/05/08- Issue H

Bay Type 5
39

Ethernet Architecture : Large Dual physical star

PACiS OI

PACiS GATEWAYS

Substation Level
MiCOM H600
Optical star switch

MiCOM H36x
Din Case

C264C

C264

Ethernet
up to 6 links
C264C

MiCOM M

Bay level
Type 1
40

> PACiS short EN 20/05/08- Issue H

RS485-up
to 4 links

Ethernet
up to 4
links
Bay level
Type 2

Bay level
Type 3
40

Ethernet Architecture : Multi-rings

PACiS OI

PACiS OI

PACiS OI

SCADA GATEWAYS
PACiS OI

Ring A

GATEWAY
IEC/IEC

PACiS OI

Ring B

H352

41

> PACiS short EN 20/05/08- Issue H

Ring C

C264
+ SWR

H352

C264
+ SWR

41

Multi-ring architecture Customer requirements


DCS for complex substations (high number of bays / cells)
High number of IEC 61850 equipments BCU, Protection
relays
Segregation of voltage levels signalization, command,
maintenance
Simple and compact system
Flexibility in outage & commissioning program
Increased reliability
Unique point of control

42

> PACiS short EN 20/05/08- Issue H

42

Complex substations solutions


Subsystem for each voltage level
Own Operator Interface Server and Workstations
Own Database storage for events and measurements
General view for single line diagram and system
Detailed views for cells status, commands, measurements
Supervision of all protection relays in the subsystem
Own dual optical fiber redundant ring
Own Gateway (T101)
System bus network traffic decrease

Main (top) Subsystem


General single line diagram and system view for entire substation
Unique point of command for entire substation
Receive only necessary information from subsystems positions, some
measurements
Can perform only a limited (predefined) number of commands switching
equipment commands
Provides the main communication channel to upper level of SCADA
(Dispatch center)
Low network traffic on the main system bus
43

> PACiS short EN 20/05/08- Issue H

43

Increased reliability and security

Distributed DB double storage if required


Multiple redundant optical rings
Redundant IEC/IEC Gateway
Lower network traffic on each ring
An eventual failure of a subsystem component or even an entire subsystem will not
affect the functionality of the other subsystems
Subsystem based user access rights. Same user can have different access right on
different subsystems
Dedicated IEC/IEC gateways no rotating components

Distribution of processing
All logics run in the own subsystem only intersystem inputs/outputs are crossing
through IEC/IEC Gateway
Detailed information available and stored only in the origin subsystem
Relay parameterization network for each subsystem
Smaller event database

Easy installation and commissioning


Each subsystem can act like an stand-alone system and it can be commissioned
without interfering with other running subsystems
Any maintenance activity on one subsystem will not affect the other subsystems
An eventual configuration upgrade will affect only the destination subsystem
Easy to maintain smaller configuration database
44

> PACiS short EN 20/05/08- Issue H

44

PACiS GTW : the SCADA interface


Direct interface through serial and Ethernet connections
Integrated MiCOM H Ethernet switch boards

Redundancy capabilities

Physical support (RS or Ethernet)


Global GTW

Serial protocols

IEC 60870-5-101 (KEMA certified)


MODBUS
DNP3
GI74
HNZ

Ethernet protocols

IEC60870-5-104
OPC
IEC61850 (Reports only)
MODBUS over IP
DNP3 over IP

45

> PACiS short EN 20/05/08- Issue H

45

Project examples

46

> PACiS short EN 20/05/08- Issue H

46

Transmission Utility Application


220 kV susbtation for FEDA (ANDORRA)
Passerelle
redonde

Poste Oprateur 2
N
(redondant
)

Poste Oprateur 1
N

Poste Ingnirie

raccordement
au SCADA
FEDA
Imprimante CDE 1
N

Imprimante CDE N
2
(redonde
)

Tranche Gnrale
redonde
Switch N
1

Switch N
2
Imprimante
graphique

Anneau Optique
Ethernet redondant
IEC 61850
IRIGB clock

Ligne RANSOL
47

Ligne MARGINEDA
1

> PACiS short EN 20/05/08- Issue H

Ligne MARGINEDA
2

Ligne GRAU ROIG

COUPLAGE

Ligne CENTRALE

Contrle BARRE
47

Distribution Utility Application


132/11 kV susbtations for DEWA (DUBAI UAE)

48

> PACiS short EN 20/05/08- Issue H

48

Oil & Gaz Application


Dolphin site with Fast Load shedding (< 80 ms)
CENTRAL CONTROL ROOM

SYSTEM MAINTENANCE AND


ENGINEERS ROOM

MS1
Ethernet TCP/IP
100Mb/s

Fast Load Sheeding

1 BM9200
3 BM9100
+5
BM9200

7 C264C
+ 4 C264

Hardwire DO
TeleProtection
To SS40

Master FLS

HUB

HUB
IEC-60870-101

To Bay
Computers in
SS40

TO
KAHRAMAA

2 BM9200

3 C264
+ 4 C264C

SS1

2 C264C
+ 1 C264

2 BM9200
SS11

2 C264
+ 5 C264C

2 BM9200
SS12

OPC

OPC

OPC

PMS server

2 BM9200
SS30

3 C264C

2 BM9200
SS3B

3 C264C

2 BM9200

2 C264
+ 5 C264C

SS2

2 BM9200
1 C264
+ 2 C264C
SS21

2 BM9200
SS14

3 C264C

2 BM9200
SS3A

> PACiS short EN 20/05/08- Issue H

2 BM9200
4 C264
+ 3 C264C

SS22

4 C264
+ 3 C264C

2 BM9200

FO From MS1

FO From MS1

HUB

SS24

TeleProtection

Hardwire DO

1 C264
+ 4 C264C
49

ITR0 / SS0

GPS Clock

HUB

3 C264
+ 6 C264C

1 BM92003 C264C

TO ICSS TO ICSS TO RTDB

SS40
49

Railway Application
Metro substations for RATP (Metro of PARIS FRANCE)

50

> PACiS short EN 20/05/08- Issue H

50

Industrial Application
Georges Besse II for AREVA (Nuclear factory FRANCE)

51

> PACiS short EN 20/05/08- Issue H

51

Sensitive building Application


Tour Granite with Load Management (PARIS FRANCE)

52

> PACiS short EN 20/05/08- Issue H

52

Automation Romania portofolio


Distribution Electrica
110/20 kV Sibiu Aeroport substation with PACiS system
Operator interface server and client in substation
Remote client at Electrica Sibiu
Redundant optical fiber ring to connect system elements
GPS synchronization
Upper scada interface with Helios system via T101 protocol
5 HV bays H type substation
30 + 20 MV cells in substation + PA
LV internal services monitoring

110/20 kV Dumbrava Sibiu substation with PACiS system


Similar with Sibiu Aeroport
In final commissioning stage

53

> PACiS short EN 20/05/08- Issue H

53

Automation Romania portofolio


Transport Transelectrica
11 Substations pure automation project with PACiS
system

220/110/20 kV substations : Targoviste, Cluj Floresti, Turnu


Magurele, Stuparei, Isalnita, FAI, Baia Mare, Pestis, Arefu, Hasdat,
Raureni
Project was started in 2005 and its still running until December
2010.

220/110 kV Paroseni substation turn-key project with


Pacis system finalized 2007
400 kV Moldova Axis turn-key project with Pacis system
Including Bacau Sud, Roman Nord, Suceava substations
finalized 2009

54

> PACiS short EN 20/05/08- Issue H

54

Automation Romania portofolio


Transport Transelectrica
400/220/110/20 kV Lacu Sarat turn-key project with Pacis
system in progress
110kV Gutinas turn-key project with Pacis system in
progress

400/110kV Tariverde turn-key project with Pacis system


in progress

Railways CFR
Campina Predeal traction substations automation
project with Pacis system in progress

55

> PACiS short EN 20/05/08- Issue H

55

www.areva-td.com

You might also like