You are on page 1of 12

CASING and CEMENTING Module

Lease and Block: West Cameron Block 180

Well Name & No:

OCS-G-Number: 2820

Permit MD: 11,712'

Prepared By: BDS

Permit TVD: 10,830'

VENDORS:
Casing Crews & Service:
Cement & Cement Service:
Cement Accessories:
Liner Equipment & Service:
Mudline Hanger & Service:
Other Related Services:
Wellhead Equipment:

KOP: 4,137'
Date: October 28, 2015

Frank's Casing Crews


Halliburton
Gemoco, Centralizers. Davis Lynch, Float Equipment
0
0
0
Cameron-Cooper

DEPTH CASING POINTS:


Drive Pipe:
Conductor:
Surface:
Intermediate:
1st Drilling Liner:

357'
None
3,400'
9,748'
None

2nd Drilling Liner:


Production Liner:
Production Tie-back String:
Production Long String:

1. DRIVE PIPE . . . .
OD Drive Pipe:

20"

Penetration BML:

205'

Wall Thickness: 0.50"


Pre Driven:

Slot:

Yes

Air Gap:

Water Depth:

48'

Wellhead: 20" 2M Swedge Flanged For NU Hydril and Diverter System


Accessories: 20" Hydrill with Diverter System
0

2. CONDUCTOR CASING . . . .
Hole Size:
Setting Depth, MD:

0.000"

Casing OD:

0'

Setting Depth, TVD:

INTERVAL

0.000"
0'

Interval

Cum

From

To

Footage

Wt/Ft

Conn

Grade

Weight

Weight

Tension

0
0

0
0

0
0

0.00
0.00

0.00
0

0
0

0
0

0
0

0.00

Design Conditions Backup Gradient:

, ppg

Mud Weight:

0.0

, ppg

Fracture Gradient:

0.0

, ppg

Cement Design % Excess OH:

Sacks of Lead:

Cement Top:

0'

Slurry Wt. Lead:

Thickening Time:

0.0 hr

Yield, ft/sx Lead:

0.00

Placement Time:

0.0 hr

Volume, ft Lead:

Type Lead Cement:

Type Tail Cement:

Well head:

Accessories:

0
0

Page 1

3. SURFACE CASING . . . .
Hole Size:

17.500"

Setting Depth, MD:

Casing OD:

3,400'

Setting Depth, TVD:

INTERVAL

13.375"
3,400'

Interval

Cum

From

To

Footage

Wt/Ft

Conn

Grade

Weight

Weight

Tension

0
0

3,400
0

3,400
0

61.00
0.00

Buttress
0

K-55
0

207,400
0

207,400
0

4.64
0.00

Design Conditions Backup Gradient:

8.942

Mud Weight:

9.4

, ppg

Fracture Gradient:

14.3

, ppg

, ppg

Cement Design % Excess OH:

100

Sacks of Lead:

1,366

Cement Top:

48'

Slurry Wt. Lead:

11.4

Thickening Time:

5.0 hr

Yield, ft/sx Lead:

2.81

Placement Time:

3.5 hr

Volume, ft Lead:

3,840

Type Lead Cement: PREMIUM + 3% ASM + .25% D-Air-1


Type Tail Cement: PREMIUM + .25% D-Air-1
Well Head: 13-3/8" x 13-5/8" 5M SOW Head with two 2 1/16" 5M Gate Valves on flanged outlets
Backup SOW Head Configured same
Accessories: Cementing Head and Swage with Buttress connection
Pre-installed 13-3/8" Float Shoe and Collar, Top and Bottom Plugs, 6-Turbolators.

4. INTERMEDIATE CASING . . . .
Hole Size:

12.250"

Setting Depth, MD:

9,746'

Casing OD:

9.625"

Setting Depth, TVD:

9,128'

Interval

Cum

From

INTERVAL
To

Footage

Wt/Ft

Conn

Grade

Weight

Weight

Tension

0
0

9,746
0

9,746
0

47.00
0.00

LT&C
0

S95
0

458,062
0

458,062
0

2.27
0.00

Design Conditions Backup Gradient:

8.942

, ppg

Completion Fluid Wt:

13.2

Pore PSI For MASP:

12.0

, ppg

TVD For MASP:

9,128'

50

Sacks of Lead:

1,960

Cement Top MD:

3,000'

Slurry Wt. Lead:

14.5

Thickening Time:

6.0 hr

Yield, ft/sx Lead:

1.61

Placement Time:

3.0 hr

Volume, ft Lead:

3,156

, ppg

Cement Design % Excess OH:

Spacer: 50 bbls Dual Purpose @ 13.5 ppg


Type Lead Cement: Premium + 15% Salt + 4% Gel + 3/4% CFR-2 + Retarder for 6 hr. Pumping Time
Type Tail Cement: None
Well head: 13-5/8" 5M x 10" 5M Tubing Spool with flg outlets, two 2-1/16" 5M Gate Valves Installed
Type "S" Slip and Seal Ass'y
Accessories: Pre-installed Float Shoe and Collar, Top and Bottom Plugs
50 Turbolators, Cementing Head and Swedge with LT&C threads

Page 2

5. PRODUCTION CASING . . . .
Hole Size:
Setting Depth, MD:

9.875"

Casing OD:

7.625"

11,712'

Setting Depth, TVD:

10,830'

Interval

Cum

From

INTERVAL
To

Footage

Wt/Ft

Conn

Grade

Weight

Weight

Tension

0
0

11,712
0

11,712
0

33.70
0.00

LT&C
0

S95
0

394,694
0

394,694
0

1.98
0.00

Design Conditions Backup Gradient:

12.0

, ppg

Completion Fluid Wt.:

13.2

Pore PSI For MASP:

11.8

, ppg

TVD For MASP:

10,830'

50

Sacks of Lead:

777

Cement Top:

3,400'

Slurry Wt. Lead:

14.5

Thickening Time:

5.0 hr

Yield, ft/sx Lead:

1.61

Placement Time:

4.0 hr

Volume, ft Lead:

1,251

, ppg

Cement Design % Excess OH:

Spacer: 50 BBLS Dual Purpose mixed @ 15.0 ppg


Type Lead Cement: PREMIUM + 8%KCl + .6%Halad 22-A + 3/4% CFR-2 + Retarder for 6 hrs Pumping
0
Type Tail Cement: None
Well head: 1-12" x 7 5/8" Type 'CA' Slip and Seal Ass'y and 1-12" x 7-5/8" X-bushing
10" 5M Dry Hole Tree w/one 2-1/16" 5M Gate Valved installed
Accessories:

0
7-5/8" Float Collar and Shoe Pre-installed, 60-Turbolators, Top & Bottom Plugs.
Cementing Head and Swage with LT&C Connections, Thread Lock, Casing Dope
0
0
0
0

Operational comments for special tubulars, handling tools, running procedures, cementing procedures, cem

accessories, cement testing, casing and shoe testing, wellhead equipment, or other relevant to string in qu

Drive Pipe:
Install 6" Air Operated Valve 12' above water line for lost returns.

Conductor Casing:
None required.

Surface Casing:

Intermediate Casing:

Production Long String or Liners:


Torque Turn this string.

Page 3

6. PRODUCTION LINER . . . .
Hole Size:

0.000"

Casing OD:

0.000"

Setting Depth, MD:

0'

Setting Depth, TVD:

0'

Top of Liner, MD:

0'

Top of Liner, TVD:

0'

Interval

Cum

From

INTERVAL
To

Footage

Wt/Ft

Conn

Grade

Weight

Weight

Tension

0.00

0.00

0.00

Design Conditions Backup Gradient:

0.0

, ppg

Completion Fluid Wt.:

0.0

Pore PSI For MASP:

0.0

, ppg

TVD For MASP:

0'

, ppg

Cement Design % Excess OH:

Sacks of Lead:

Cement Top:

0'

Slurry Wt. Lead:

Thickening Time:

0.0 hr

Yield, ft/sx Lead:

Placement Time:

0.0 hr

Volume, ft Lead:

Spacer:

Type Lead Cement:

0
0

Type Tail Cement:

Well head:

0
0

Accessories:

0
0
0

Liner Equipment:

0
0

Page 4

DRILLING CASING LINER SECTION


Hole Size:

0.000"

Casing OD:

0.000"

Setting Depth, MD:

0'

Setting Depth, TVD:

0'

Top of Liner, MD:

0'

Top of Liner, TVD:

0'

Interval

Cum

From

INTERVAL
To

Footage

Wt/Ft

Conn

Grade

Weight

Weight

Tension

0.00

0.00

0.00

Design Conditions Backup Gradient:

0.0

, ppg

Completion Fluid Wt.:

0.0

Pore PSI For MASP:

0.0

, ppg

TVD For MASP:

0'

, ppg

Cement Design % Excess OH:

Sacks of Lead:

Cement Top:

0'

Slurry Wt. Lead:

Thickening Time:

0.0 hr

Yield, ft/sx Lead:

Placement Time:

0.0 hr

Volume, ft Lead:

Spacer:

Type Lead Cement:

0
0

Type Tail Cement:

Well head:

0
0

Accessories:

0
0
0

Liner Equipment:

0
0

Page 5

DRILLING CASING LINER SECTION


Hole Size:

0.000"

Casing OD:

0.000"

Setting Depth, MD:

0'

Setting Depth, TVD:

0'

Top of Liner, MD:

0'

Top of Liner, TVD:

0'

Interval

Cum

From

INTERVAL
To

Footage

Wt/Ft

Conn

Grade

Weight

Weight

Tension

0.00

0.00

0.00

Design Conditions Backup Gradient:

0.0

, ppg

Completion Fluid Wt.:

0.0

Pore PSI For MASP:

0.0

, ppg

TVD For MASP:

0'

, ppg

Cement Design % Excess OH:

Sacks of Lead:

Cement Top:

0'

Slurry Wt. Lead:

0.0

Thickening Time:

0.0 hr

Yield, ft/sx Lead:

Placement Time:

0.0 hr

Volume, ft Lead:

Spacer:

Type Lead Cement:

0
0

Type Tail Cement:

Well head:

0
0

Accessories:

0
0

Liner Equipment:

0
0

Page 6

G-11

0
Rig Elevation: 104'

October 28, 2015

None
None
None
11,712'

104'

Pipe ID:

19.0"

Setting Depth:

357'

Drift Diameter:

0.000"

Clearance:

0.000"

DESIGN SAFETY FACTOR


Collapse

Top Burst

Btm Burst

0.00
0.00

0.00

0.00

Gas Gradient:

0.000

MASP, psi:

Sacks of Tail:

Slurry Wt. Tail:

Yield,, ft/sx Tail:

Volume, ft Tail:

Page 7

Drift Diameter:

12.515"

Clearance:

1.563"

DESIGN SAFETY FACTOR


Collapse

Top Burst

Btm Burst

1.16
0.00

1.41
0.00

1.84
0.00

Gas Gradient:

0.100

MASP, psi:

2,193

Sacks of Tail:

650

Slurry Wt. Tail:

15.6

Yield, ft/sx Tail:

1.18

Volume, ft Tail:

767

Drift Diameter:

8.681"

Clearance:

0.813"

DESIGN SAFETY FACTOR


Collapse

Top Burst

Btm Burst

1.41
0.00

1.62
0.00

1.10
0.00

Fracture Gradient:

#REF!

Mud Weight:

12.5

MASP, psi:

5,021

Sacks of Tail:

None

Slurry Wt. Tail:

Yield, ft/sx Tail:

Volume, ft Tail:

Page 8

Drift Diameter:

6.875"

Clearance:

0.625"

Estimated BHT:

180 F

DESIGN SAFETY FACTOR


Collapse

Top Burst

Btm Burst

1.18
0.00

1.87
0.00

1.30
0.00

Mud Weight:

13.2

MASP, psi:

5,021

Sacks of Tail:

None

Slurry Wt. Tail:

Yield, ft/sx Tail:

Volume, ft Tail:

ng tools, running procedures, cementing procedures, cementing

ng, wellhead equipment, or other relevant to string in question.

Page 9

Drift Diameter:

0.000"

Clearance:

0.000"

DESIGN SAFETY FACTOR


Collapse

Top Burst

Btm Burst

0.00

0.00

0.00

Mud Weight:

0.0

MASP, psi:

Sacks of Tail:

Slurry Wt. Tail:

Yield, ft/sx Tail:

Volume, ft Tail:

Page 10

Drift Diameter:

0.000"

Clearance:

0.000"

DESIGN SAFETY FACTOR


Collapse

Top Burst

Btm Burst

0.00

0.00

0.00

Mud Weight:

0.0

MASP, psi:

Sacks of Tail:

Slurry Wt. Tail:

Yield, ft/sx Tail:

Volume, ft Tail:

Page 11

Drift Diameter:

0.000"

Clearance:

0.000"

DESIGN SAFETY FACTOR


Collapse

Top Burst

Btm Burst

0.00

0.00

0.00

Mud Weight:

0.0

MASP, psi:

Sacks of Tail:

Slurry Wt. Tail:

Yield, ft/sx Tail:

Volume, ft Tail:

Page 12

You might also like