You are on page 1of 42

1 80dBA

22.5 3

LCD

8 5W

85265VAC5060Hz

0.2A AC

4~20mA

RS485

2
250VAC10A

0~+40

10-95RH

86-106Kpa

0~+4010~95RH

800 X 600 X 2100

800 X 800 X 2100 800 X 600 X 2300


800 X 600 X 2200

32

40

12

34

5678

Lmm

88.8

88.8

88.8

Wmm

110

214

318

(mm2)

0.75

1.0

1.5

2.5

(m)

500

700

100

1700

<=

>=

, (A1)
LED
A1

>=

, (A2)
LED
A2 ()
A1A2 ()

LED

A2 ()
A1A2 ()

LED ,
ErrF ()

sss

P-00

P-01

P-02

A2A1
5

P-03

P-04

P-40
P-41

P-05

A1A2

P-07

P-08

/
2 A2

P-06

U&R

( )

60%)

40%

Basic parameters
Installation style:

wall type indoor

Alarm mode:

audial, visual and LCD display.


Audial alarm: =80Dba within 1 meter;
Visual alarm: clearly identified within 3 meters at frontward 22.5

Display mode:

LCD code segment;

Capacity:

8 channel, 5W for each panel.

Electronic characters
Rated voltage:
Rated current:

85265VAC5060Hz 1832VDC
0.2A AC 1.5ADC

Input signal:

4-20mA, 3-wire or 2-wire

Communication

RS485

style:
Relay output:

2 passive NO, NC contacts,


Contact capacity 250VAC, 10A

Safety

maximum voltage: 21VDC

barrier output:

Maximum current: 150mA


Maximum power: 3.2W
Maximum permissible external inductance value: 4mH
Maximum permissible external capacitance value: 4.7uF

Environmental requirements
Working
temperature:

0~+40

Working

10-95%RH (non-condensing)

humidity:
Working
pressure:
Storage
condition:

86-106Kpa
0-+40, 10-95%RH (non-condensing)

800 X 600 X 2100


cabinet dimension

800 X 800 X 2100

800 X 600 X 2300

800 X 600 X 2200


maximum channels

32

40

12

34

5678

Lmm

88.8

88.8

88.8

Wmm

110

214

318

Cross-sectional Area (mm2)

0.75

1.0

1.5

2.5

Maximum distance

500

700

100

1700

Controller Status

Normal monitoring

Condition

Condition Display

Field gas concentration does not


meet the condition of alarm.

System do not alarm (fault alarm indicator


extinguish, no audial alarm), channel normally
display gas concentration value and time.
Audial alarm, LCD display A1 LEL alarm, red LED

LEL alarm

Gas concentration=LEL value

is lit (flash for first alarm), alarm time locked A1


relay act.
Audial alarm, A2 UEL alarm is displayed, red LED

UEL alarm

Gas concentration=UEL value

is lit(flash for first alarm), alarm time locked.


A1, A2 act.

Concentration over range

Detector fault

Power supply fault

Gas

concentration

exceed

Red LED flash, LCD light column flash, audial UEL

detector inspection scope

sounds, A1, A2 act.

Detector fault, or the connection

Yellow LED wink, Err is displayed on LCD, audial

wire with controller fault.

fault alarm, F relay act.

Main power or standby power do


not work normally

Main and standby power indicator of public module


separately indicates main and standby power
working condition and speaker sounds alarm.

Password

Operation right

Operator

Up, down

Reset, self test, check history record, time setting

Administrator

Up, down

Zeroing, calibrating, alarm setting point, gas unit and range setting,

Up, down

check history record, time setting, Reset, self test, check channel
address, relay setting.

Menu NO

Menu Icon

Chinese Name

Description
When field gas concentration Resets to be safe

P-00

Reset

condition, Reset function can eliminate audial,


visual alarm and locking condition of relay.

P-01

Self test

P-02

Check history record

P-03

Setting time

P-04

Zeroing and calibrate

Perform function inspection of controller.


Including A2, A1, fault, power on and power off
history record.
Set system time
Format: year month date hour minute
Enter the menu, P-40 is for zeroing and P-41 is for
calibration.

P-05

Alarm point setting

Alarm limit of A1, A2 alarm point

Set range and unit

Set inspection range and unit of detector

P-07

Check channel address

Check current address of the channel

P-08

Relay setting

P-06

U&R

Set output impulse/ level of relay, set relay 2 for A2


alarm or fault alarm.

COMMON PROBLEMS

ANALYSIS

SOLUTION
Check power supply of system, power
supply circuit is normal or not, if not,
professional personnel repair; check soft

No Display after power on

Power fault or bad contact


cable between controller control board
and terminal board is connected correctly
and not loosen.
Alarm system is installed well (including
replacing detector), after warming up first,
alarm or fault alarm may appear, zero to
Not zeroing after replacing or
Reset normal;

Alarm fault or alarm after warming up

installing new detector;


Mostly the problem in detector circuit or
Circuit or power supply fault.
without standby power supply. Check
carefully detector circuit and stand by
battery.
Work cycle of detector is too long, the
sensitivity of sensor to targeted gas

Fail in controller zeroing and calibrating

Detector fault

degradation, first zero and calibrate


detector (calibration gas is better to be
40%-60% of detected gas).