You are on page 1of 23

ZXSDR B8200 L200

LTE Baseband Unit

Routine Maintenance Guide


Hardware Version: HV3.10

ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://support.zte.com.cn
E-mail: support@zte.com.cn

LEGAL INFORMATION
Copyright 2014 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.

Additionally, the contents of this document are protected by

contractual confidentiality obligations.


All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History
Revision No.

Revision Date

Revision Reason

R1.1

2014-10-30

Added BPN0A in 2.2 Version Information Collection Table

R1.0

2014-09-18

First edition

Serial Number: SJ-20140807141023-005


Publishing Date: 2014-10-30 (R1.1)

SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Contents
About This Manual ......................................................................................... I
Chapter 1 Overview .................................................................................... 1-1
1.1 Maintenance Categories ..................................................................................... 1-1
1.2 Precautions........................................................................................................ 1-1

Chapter 2 Maintenance Information ......................................................... 2-1


2.1 Basic Maintenance Information Collection Table ................................................... 2-1
2.2 Version Information Collection Table .................................................................... 2-2

Chapter 3 Routine Maintenance................................................................ 3-1


3.1 Definition of Routine Maintenance ....................................................................... 3-1
3.2 Routine Maintenance Items................................................................................. 3-1
3.3 Daily Maintenance Items..................................................................................... 3-2
3.4 Monthly Maintenance Items ................................................................................ 3-2
3.5 Quarterly Maintenance Items .............................................................................. 3-3
3.6 Semiannual Maintenance Items .......................................................................... 3-3
3.7 Annual Maintenance Items.................................................................................. 3-4

Chapter 4 Maintenance Record Table....................................................... 4-1


4.1 Daily Maintenance Record .................................................................................. 4-1
4.2 Monthly Maintenance Record.............................................................................. 4-2
4.3 Quarterly Maintenance Record............................................................................ 4-3
4.4 Semiannual Maintenance Record ........................................................................ 4-4
4.5 Annual Maintenance Record ............................................................................... 4-4
4.6 Emergency Fault Handling Record ...................................................................... 4-6
4.7 Module Replacement Record .............................................................................. 4-7
4.8 Cable Replacement Record ................................................................................ 4-7

Glossary .......................................................................................................... I

I
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

This page intentionally left blank.

II
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

About This Manual


Purpose
This manual describes how to maintain the ZXSDR B8200 L200.

Intended Audience
This manual is intended for:
l
l

Hardware installation engineers


Maintenance engineers

What Is in This Manual


This manual contains the following chapters.
Chapter 1, Overview

Describes the routine maintenance principles, categories,


methods, and precautions of the ZXSDR B8200 L200.

Chapter 2, Maintenance

Describes the templates for collecting the maintenance

Information

information of the ZXSDR B8200 L200.

Chapter 3, Routine Maintenance

Describes the routine maintenance items of the ZXSDR B8200


L200.

Chapter 4, Maintenance Record

Provides maintenance record tables for your reference.

Table

Related Documentation
The following documents must be available before maintenance:
l
l

Personal Health and Safety Information


System Security Information

The following documentation is related to this manual:


l
l
l
l

ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Hardware Description


ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Product Description
ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Hardware Installation
ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Alarm and Notification Reference

Conventions
This manual uses the following conventions.

I
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Danger: indicates an imminently hazardous situation. Failure to comply can result in


death or serious injury, equipment damage, or site breakdown.
Warning: indicates a potentially hazardous situation. Failure to comply can result in
serious injury, equipment damage, or interruption of major services.

II
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 1

Overview
Table of Contents
Maintenance Categories.............................................................................................1-1
Precautions ................................................................................................................1-1

1.1 Maintenance Categories


Maintenance can be classified into three categories: routine maintenance, notification
handling, and alarm handling.

Routine Maintenance
Routine maintenance means periodical maintenance. It involves checking the operation
of equipment periodically. Any problems detected during the inspection should be handled
immediately to prevent accidents.

Alarm/Notification Handling
Notification handling involves analyzing the notifications generated during system
operation, determining whether faults exist, and taking proper measures as required.
Alarm handling involves analyzing the alarms generated during equipment operation,
determining whether faults exist, and taking proper measures as required. For a
description of notification and alarm handling, refer to the ZXSDR B8200 L200(HV3.10)
LTE Baseband Unit Alarm and Notification Reference.

1.2 Precautions
During routine maintenance, follow the precautions below:
l
l

Keep the equipment room dry, clean, and at normal temperature. Keep rats or other
animals out of the equipment room.
Ensure that the primary power supply of the system is stable and reliable. Check
the system grounding and the lightning protection grounding regularly. Ensure that
the lightning protection system is in good condition especially before a thunderstorm
season or after a thunderstorm.
Formulate complete rules for routine maintenance. Keep a detailed duty log of
the operations, versions, data changes, upgrade, and faults of the system for fault
analysis and handling. Ensure a shift change record is available denoting clear
responsibility.

1-1
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

l
l

l
l
l
l

Never play games or surf the Internet on the PC. Never install, run, or copy any
software not related to the system on the PC. Never use the PC for other purposes
not related to work.
Set the NetNumen passwords based on user levels and keep them open only to
maintenance personnel. Manage the passwords strictly and change them regularly.
Receive induction training to learn about the equipment and network. Perform
maintenance operations according to the instructions described in related manuals.
Wear an antistatic wrist strap before touching the equipment to prevent accidents
caused by human errors.
Do not reset the equipment, load or modify data without permission, especially the
EMS database data. Data must be backed up before it is modified. A record of
the modification should be made at the time. After data modification, the backup
data cannot be deleted until the system operates properly for a certain period of time
(generally one week).
Prepare the following common instruments and meters: flat head screwdriver, cross
screwdriver, signaling analyzer, network cable pliers, multimeter, AC power supply for
maintenance, telephone line, and network cable. Test the meters regularly to ensure
accuracy.
Inspect spare parts and accessories regularly to keep them in stock and in good
condition. Protect them against moisture and mould. Separate the spare parts and
accessories from the replaced parts and accessories and label them respectively.
Replenish the common spare parts and accessories as they are used up.
Keep any software and documentation that may be used during maintenance in a
specified handy place for use when required.
Lighting in the equipment room should meet maintenance requirements. Repair any
broken lights in time.
Solve any detected problems in time. For any problems that cannot be handled,
contact the local ZTE office.
Place the contact information of the local ZTE office in a handy place and make it
known to all maintenance personnel. Update the contact information regularly.

Danger!
Power supply inspection and adjustment must be performed by professionals. Otherwise,
injury, death, and equipment failures may occur.

Warning!
Data cannot be modified or synchronized without permission of the person in charge.
Otherwise, major accidents may occur.

1-2
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 2

Maintenance Information
Table of Contents
Basic Maintenance Information Collection Table.........................................................2-1
Version Information Collection Table...........................................................................2-2

2.1 Basic Maintenance Information Collection Table


Table 2-1 lists the equipment information to be collected during maintenance for the
ZXSDR B8200 L200.
Table 2-1 Basic Maintenance Information Collection
Basic Maintenance Information Collection
ZXSDR B8200

North latitude

L200 name
ZXSDR B8200

East longitude

L200 type
ZXSDR B8200

Altitude

L200 No.
ZXSDR B8200
L200 ID
(configured on
the OMC)
City/County

Telephone
number of
the equipment
room

Position of
the equipment
room
Daisy chain
mode adopted
(description
of the link
structure)

2-1
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

2.2 Version Information Collection Table


Version information of the ZXSDR B8200 L200 should be collected and recorded for
maintenance. Table 2-2 lists the ZXSDR B8200 L200 version information to be collected.
Table 2-2 Version Information Collection
Module

Version

CC
CC16B
CCE1
BPL1
BPL1A
BPN0A
BPN0
FS5
CR0
SA
SE
UES
UCI
FA
PM
Remarks:

2-2
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 3

Routine Maintenance
Table of Contents
Definition of Routine Maintenance ..............................................................................3-1
Routine Maintenance Items ........................................................................................3-1
Daily Maintenance Items ............................................................................................3-2
Monthly Maintenance Items........................................................................................3-2
Quarterly Maintenance Items......................................................................................3-3
Semiannual Maintenance Items .................................................................................3-3
Annual Maintenance Items .........................................................................................3-4

3.1 Definition of Routine Maintenance


Routine maintenance means to perform a preventive inspection regularly on the equipment
to ensure the equipment operates properly for a long time.
Routine maintenance mainly covers the following two types:
l

Regular inspection and testing


Inspect and test the operation, functions, major performance indicators, and hardware
condition of the ZXSDR B8200 L200 regularly through OMC operations, or with
appropriate instruments and meters according to the technical specifications and
requirements for the equipment parts.

Regular checking and cleaning


Check the hardware of the ZXSDR B8200 L200 and its auxiliary devices. If any
problem is detected, adjust, fix, or replace the faulty parts immediately to ensure
that the hardware remains intact. Regularly maintain and clean the parts that are
vulnerable or must be dust-free. Regularly clean the major parts of other peripheral
equipment for proper operation.

Work out a reasonable maintenance schedule and perform routine maintenance on


schedule.

3.2 Routine Maintenance Items


Routine maintenance includes various regular checks and maintenance tasks that ensure
the equipment operates in the best condition to meet the service requirements of users
and to prevent potential failures.
Routine maintenance of the equipment includes but is not limited to the following items:
l

Inspection of the operating environment of the equipment


3-1

SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

l
l
l
l
l
l
l
l
l
l

Collection of performance statistics


Alarm system maintenance
Data backup
Spare parts inspection
Board maintenance
Log inspection
Inspection of the grounding and lightning protection systems
Power supply inspection
Inspection of the antenna feeder system
Preparation before holidays

3.3 Daily Maintenance Items


Table 3-1 lists the daily maintenance items of the ZXSDR B8200 L200.
Table 3-1 Daily Maintenance Items
Item

Sub-item

Action

Checking

Handling alarms

Check all the alarms that are generated since the

alarms and

last inspection on the EMS and categorize and

notifications

handle the alarms based on alarm levels.


Handling notifications

Analyze the notifications that occur frequently.


Ignore common notifications.

Troubleshoot-

Handling common faults

ing

Handle the common faults, such as transmission


failures and board faults.

Handling user complaints

Analyze and handle the problems that users


complain about, for example, network quality.

3.4 Monthly Maintenance Items


Table 3-2 lists the monthly maintenance items of the ZXSDR B8200 L200.
Table 3-2 Monthly Maintenance Items
Item

Action

Checking the temperature and

Check the temperature and humidity of the equipment room.

humidity

Check the temperature through the alarm management system of


the OMC and measure the humidity with a hygrometer.

Checking the operation of

Check the operation of modules through the alarm management

modules

system of the OMC. For any faulty modules, diagnose the faults
through the diagnostic test system.

3-2
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 3 Routine Maintenance

Item

Action

Checking the voice and data

Perform the tests with a terminal on site. Observe and survey the

services

services in each sector. Check whether there are disconnection,


interruption, or throughput errors.

Checking the operation of the

Check the power supply of the ZXSDR B8200 L200.

power module
Checking the grounding and

Inspect the operation of the grounding and lightning protection

lightning protection systems

systems and check whether the connections are secure.

3.5 Quarterly Maintenance Items


Table 3-3 lists the quarterly maintenance items of the ZXSDR B8200 L200.
Table 3-3 Quarterly Maintenance Items
Item

Action

Checking the Standing Wave

Check whether or not there are SWR alarms reported on the EMS.

Ratio (SWR) of the antenna


feeder
Measuring the grounding

Measure the grounding resistance with a grounding resistance

resistance value and checking

tester, and check whether or not the resistance value is correct.

the grounding cable

Check whether or not the connectors of each grounding cable are


loose or aging.

Checking the water resistance

Check whether or not the outside surface is in good condition.

and grounding connection of

If necessary, remove the insulating tape and perform a further

the antenna feeder connector

inspection. Seal the connection again with the insulating tape after

and the lightning protection

the inspection.

grounding kit
Checking whether or not the

Check whether or not the antenna is beyond the scope specified

antenna is installed securely

by network planning due to wind blowing. Adjust the antenna with

and inspecting the pitch angle

such tools as spanners and angle gauges. Note that screw nuts

and azimuth of the directional

with a proper force.

antenna
Checking the lightning

Check whether or not the connection of the lightning protection

protection

grounding cable is secure, and check the rust resistance of the


connection.

3.6 Semiannual Maintenance Items


Table 3-4 lists the semiannual maintenance items of the ZXSDR B8200 L200.
3-3
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

Table 3-4 Semiannual Maintenance Items


Item

Action

Remark

Lightning protection

Check the working ground of the

Perform an additional check before

and grounding

equipment.

and after nature disasters such as

Check the protective ground of the

typhoons and thunderstorms.

equipment room.
Check the grounding trunk line of
the eNodeB.
Check the lightning protection
ground of the building.
Test all the grounding resistances.

3.7 Annual Maintenance Items


Table 3-5 lists the annual maintenance items of the ZXSDR B8200 L200.
Table 3-5 Annual Maintenance Items
Item

Action

Checking the cleanness and

Clean the outside surface of the cabinet with a vacuum cleaner or

airtightness of the cabinet

towel. Pay special attention to the switch or power supply and do


not touch them by mistake during cleaning. Open the cabinet and
check whether or not there is water in it and whether or not the joint
between the top and the bottom covers of the cabinet are airtight.

3-4
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 4

Maintenance Record Table


Table of Contents
Daily Maintenance Record .........................................................................................4-1
Monthly Maintenance Record .....................................................................................4-2
Quarterly Maintenance Record...................................................................................4-3
Semiannual Maintenance Record...............................................................................4-4
Annual Maintenance Record ......................................................................................4-4
Emergency Fault Handling Record .............................................................................4-6
Module Replacement Record .....................................................................................4-7
Cable Replacement Record........................................................................................4-7

4.1 Daily Maintenance Record


Table 4-1 Daily Maintenance Record
Date: Year Month Day
Duty hour: From to

Handover from:

Handover to:

Active alarm handling record of the eNodeB


eNodeB No.

Alarm content

Alarm start

Alarm end

time

time

Remark

Abnormal history alarm record of the eNodeB


eNodeB No.

Abnormal alarm content and handling

Remark

Abnormal history notification record of the eNodeB


eNodeB No.

Abnormal notification content and handling

Remark

4-1
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

User complaint handling


eNodeB No.

Complaint content and handling

Remark

Handover information:

Team leader verification:

4.2 Monthly Maintenance Record


Table 4-2 Monthly Maintenance Record
Time: Year Month Day Hour

Maintained by:

Item

Action

Description

Remark

Are the location


parameters configured
for the eNodeB the
same as the actual
parameters?
Is the rack of the
equipment clean?
Is the cable rack
secure?
Are the fiber connectors
and other cable
connectors in good
contact?
Are the indicators of the
equipment operating
properly?
Are the temperature
and humidity correct?

4-2
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 4 Maintenance Record Table

Are the voice and


data services in good
condition?
Are the grounding and
lightning protection
systems in good
condition?
Are the spare parts and

Yes No

accessories in stock
and in good condition?
Team leader verification:

4.3 Quarterly Maintenance Record


Table 4-3 Quarterly Maintenance Record
ZXSDR B8200 L200 Name:

Time: Year Month Day

Maintained by:
Item

Result

Remark

Is the ZXSDR B8200 L200

Yes No

module operating properly?


Are the data services in good

Yes No

condition?
Is the power module operating

Yes No

properly?
Are the grounding and lightning

Yes No

protection systems in good


condition?
Is the grounding resistance

Yes No

value correct and the grounding


cable in good condition?

4-3
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

Are the water resistance and

Yes No

grounding connection of the


antenna feeder connector
and the lightning protection
grounding kit in good condition?
Is the dust-proof assembly of

Yes No

the fan module cleaned?


Fault description and
troubleshooting:

Unsolved problems:

Team leader verification:

4.4 Semiannual Maintenance Record


Table 4-4 Semiannual Maintenance Record
Time: Year Month Day Hour

Maintained by:

Item

Result

Is the working ground of the

Yes No

Remark

equipment connected securely?


Is the protective ground of the

Yes No

equipment room connected


securely?
Is the grounding trunk line of the

Yes No

eNodeB connected securely?


Measure the grounding resistance.

Value:

4.5 Annual Maintenance Record


Table 4-5 Annual Maintenance Record
Equipment name:

Time: Year Month Day

Maintained by:
4-4
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 4 Maintenance Record Table

Equipment name:

Time: Year Month Day

Item

Result

Is the cabinet clean?

Yes No

Are the temperature and humidity correct?

Yes No

Is the module operating properly?

Yes No

Remark

Are the voice and data services in good condition?

Yes No

Is the power module operating properly?

Yes No

Are the grounding and lightning protection


systems in good condition?

Yes No

Is the SWR of the antenna feeder correct?

Yes No

Is the grounding resistance value correct and


the grounding cable in good condition?

Yes No

Are the water resistance and grounding connection of the antenna feeder connector and
the lightning protection grounding kit in good
condition?

Yes No

Is the antenna installed securely and are the


pitch angle and azimuth of the directional antenna correct?

Yes No

Is the lightning protection system for the antenna feeder in good condition?

Yes No

Fault description and troubleshooting:

Unsolved problems:

Team leader verification:

4-5
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

4.6 Emergency Fault Handling Record


Table 4-6 Emergency Fault Handling Record
Emergency Fault Handling Record
Site name:

Handled by:

Occurrence time:

Handling time:

Fault source:
Customer complaint Alarm system reporting Found during routine maintenance Other
Fault type:

Fault description:

Action:

Result:

Comment of the person in charge:

4-6
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Chapter 4 Maintenance Record Table

4.7 Module Replacement Record


Table 4-7 Module Replacement Record
Module Replacement Record
eNodeB No.:
Module

Maintained by:
Slot Number

Failure Time

Name

Replace-

SN of the Faulty

SN of the

ment Time

Module

Replacement
Module

4.8 Cable Replacement Record


Table 4-8 Cable Replacement Record
Cable Replacement Record
eNodeB No.:
Cable Name

Maintained by:
Cable

Failure

Replace-

SN of the Faulty

SN of the

Connection

Time

ment Time

Cable

Replacement

Position

Cable

4-7
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

ZXSDR B8200 L200 Routine Maintenance Guide

4-8
SJ-20140807141023-005|2014-10-30 (R1.1)

ZTE Proprietary and Confidential

Glossary
BPL
- Baseband Processing for LTE
CC
- Control and Clock Module
CCE
- Control Channel Element
FA
- Fan Array
FS
- Fabric Switch Module
OMC
- Operation & Maintenance Center
PM
- Power Module
SA
- Site Alarm
SE
- Site Alarm Extender
UCI
- Universal Clock Interface
UES
- Universal Ethernet Switch Board

I