You are on page 1of 36

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

FEATURES

Features
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 Wall SystemTM5 is an inside glazed captured curtain wall














1600 Wall SystemTM5 has a 2-1/2" (63.5) sight line


Standard 6" (152.4) or 7-1/2" (190.5) system depths
Condensation water management capability
Integral perimeter caulk leg
Thermally improved
Snap-on covers
Optional split vertical mullion
Type "A" fabrication: Screw Spline or Shear Block
Type "B" fabrication: Punched openings
SSG Option
Two color option
PermanodicTM anodized finishes in seven choices
Painted finishes in standard and custom choices

Steel reinforcing available


Rain screen and backpans
Pressure plate option for outside glazing requirements
Integrates with concealed GLASSventTM for curtain wall
Integrates with VersoleilTM Sunshade Outrigger System and Horizontal or Vertical Single
Blade Systems
Profit$MakerTM plus die sets available
Product Applications

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Optional Features

Ideal for low-rise to mid-rise curtain wall applications where inside glazing and high
performance is desired for ribbon windows and multi-lite punched openings in both
new and remodel construction projects
For specific product applications,
Consult your Kawneer representative.

kawneer.com

ADMD050

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 WALL SYSTEMTM5

BLANK PAGE

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

2
DECEMBER, 2013
EC 97911-053

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

INDEX

PICTORIAL VIEW.............................................................................. 4-7


1/4 SIZE DETAILS........................................................................... 8-11
ENTRANCE DETAILS........................................................................ 12
CORNERS........................................................................................... 13
VENT OPTIONS.................................................................................. 14
MISCELLANEOUS............................................................................. 15
WIND LOAD CHARTS................................................................... 16-24
DEADLOAD CHARTS........................................................................ 25
THERMAL CHARTS...................................................................... 26-35

LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
( ) are millimeters unless otherwise noted.
Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

Architects Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.

The following metric (SI ) units are found in these details:



m meter

cm centimeter

mm millimeter

s second

Pa pascal

MPa megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.

kawneer.com

ADMD050

VERTICAL MULLION

HEAD

GLASS STOP

THERMAL
ISOLATOR

GLASS STOP

SILL

COVER

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

PICTORIAL VIEW

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 WALL SYSTEMTM5

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

4
DECEMBER, 2013
EC 97911-053

TYPE "A" ASSEMBLY


Screw Spline for Ribbon Window

HORIZONTAL

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

DECEMBER, 2013

kawneer.com

1600 WALL SYSTEMTM5

EC 97911-053
PICTORIAL VIEW

TYPE "B" ASSEMBLY


Punched Openings

HEAD

GLASS STOP

THERMAL
ISOLATOR

HORIZONTAL

GLASS STOP

COVER
VERTICAL
MULLION

SILL

ADMD050

VERTICAL MULLION

SHEAR BLOCK

HEAD

GLASS STOP

THERMAL
ISOLATOR

GLASS STOP

FLAT FILLER

SILL

COVER

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

PICTORIAL VIEW

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 WALL SYSTEMTM5

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

6
DECEMBER, 2013
EC 97911-053

TYPE "A" ASSEMBLY


Shear Block Assembly for Curtain Wall

HORIZONTAL

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

DECEMBER, 2013

kawneer.com

1600 WALL SYSTEMTM5

EC 97911-053
PICTORIAL VIEW

TYPE "A" ASSEMBLY


Screw Spline with Split Mullion
for Curtain Wall

SPLIT MULLION

HEAD

GLASS STOP

THERMAL
ISOLATOR

HORIZONTAL

GLASS STOP

SILL

COVER

ADMD050

1A

5A

4
5

4A
5A

4
6A

3 3A

4A
6"(152.4)
6"(152.4)

7-1/2"(190.5)
7-1/2"(190.5)

1 1A

2 2A

ELEVATION IS NUMBER KEYED TO DETAILS

1
1A

2
2A

3
3A

5A

ADMD050

6
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

SCALE 3" = 1'-0'

2-1/2"
(63.5)

6A

kawneer.com

Kawneer Company, Inc., 2013

3A
6
2-1/2"
(63.5)

RIBBON WINDOW (TYPE "A" SCREW SPLINE)

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

6"(152.4)

3
2-1/2"
(63.5)

1600 WALL SYSTEMTM5

7-1/2"(190.5)

4A

6"(152.4)

7-1/2"(190.5)

8
DECEMBER, 2013
EC 97911-053

NOTE:
Available in 6" (Shown Dotted in) and 7-1/2" depths.
Consult your Kawneer Representative for more information.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

4A

kawneer.com

3A

4
5

4A
5A

4
5A

4A

2-1/2"
(63.5)

2-1/2"
(63.5)

6"(152.4)
7-1/2"(190.5)

6"(152.4)
7-1/2"(190.5)

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

DECEMBER, 2013

1600 WALL SYSTEMTM5

EC 97911-053

SCALE 3" = 1'-0"

1A
6"(152.4)
7-1/2"(190.5)

6A

1 1A

2 2A

3 3A

ELEVATION IS NUMBER KEYED TO DETAILS

ADMD050

1
1A

2
2A

3
3A

5A

RIBBON WINDOW (TYPE "B")

NOTE:
Available in 6" (Shown Dotted in) and 7-1/2" depths.
Consult your Kawneer Representative for more information.

MAX. UNIT WIDTH 24-0

6"(152.4)
7-1/2"(190.5)

2-1/2"
(63.5)

6A

6"(152.4)

6
6"(152.4)
7-1/2"(190.5)

7A

6A
8

8A

2-1/2"
(63.5)

7A

ADMD050

8A

kawneer.com

Kawneer Company, Inc., 2013

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

CURTAIN WALL (SHEAR BLOCK)

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

6A
7

6"(152.4)

NOTE:
Available in 6" (Shown Dotted in) and 7-1/2" depths.
Consult your Kawneer Representative for more information.
2-1/2"
(63.5)

1600 WALL SYSTEMTM5

7-1/2"(190.5)

7-1/2"(190.5)

10
DECEMBER, 2013
EC 97911-053

SCALE 3" = 1'-0"

ELEVATION IS NUMBER KEYED TO DETAILS

kawneer.com

NOTE:
Available in 6" (Shown Dotted in) and 7-1/2" depths.
Consult your Kawneer Representative for more information.

6A
7A
2

6A
8

ADMD050

7A

2-1/2"
(63.5)

EC 97911-053

7-1/2"(190.5)

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

6"(152.4)

7-1/2"(190.5)

6"(152.4)

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

DECEMBER, 2013

1600 WALL SYSTEMTM5


11

CURTAIN WALL (SCREW SPLINE)

SCALE 3" = 1'-0"

6"(152.4)

7-1/2"(190.5)

8A

ELEVATION IS NUMBER KEYED TO DETAILS

2-1/2"
(63.5)

8A

1600 WALL SYSTEMTM5

12

DECEMBER, 2013

ENTRANCE DETAILS (1" INFILL)

EC 97911-053

SCALE 3" = 1'-0"

1
TRANSOM BAR

BUTT HUNG OR
OFFSET PIVOT WITH
SURFACE CLOSER
OR FLOOR CLOSER
B/H OR O/P

C/H

ELEVATION IS NUMBER KEYED TO DETAILS

3
BUTT HUNG OR
OFFSET PIVOT

1A
1-15/16"
TYP.

DOOR JAMB

TRANSOM BAR

BUTT HUNG OR OFFSET PIVOT


WITH SINGLE ACTING
CONCEALED OVERHEAD CLOSER

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1 1A 1B

1B

DOOR JAMB
CENTER HUNG

TRANSOM BAR

BUTT HUNG OR OFFSET PIVOT


WITH LCN CONCEALED
OVERHEAD CLOSER
OR SURFACE CLOSER

2
TRANSOM BAR

CENTER HUNG
CONCEALED OVERHEAD
OR FLOOR CLOSER

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

7/8"
(22.2)

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

DECEMBER, 2013

kawneer.com

1600 WALL SYSTEMTM5

EC 97911-053
CORNERS

SCALE 3" = 1'-0"

90 OUTSIDE CORNER
90 OUTSIDE CORNER

90 INSIDE CORNER

90 INSIDE CORNER

ADMD050

13

HEAD

SILL

JAMB

ADMD050

JAMB AT
SSG MULLION

NOTE: Other vent types can be accommodated. Contact your


Kawneer representative for other options

HEAD

SILL

JAMB

kawneer.com

Kawneer Company, Inc., 2013

VENT OPTIONS

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 WALL SYSTEMTM5

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

14
DECEMBER, 2013
EC 97911-053

SCALE 3" = 1'-0"


GLASSventTM FOR CUTAIN WALL

8225TL IsoLockTM WINDOW SHOWN

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

15

MISCELLANEOUS

SCALE 3" = 1'-0"

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

Architects Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.

kawneer.com

PRESSURE PLATE HORIZONTAL


FOR OUTSIDE GLAZING

PRESSURE PLATE VERTICAL


FOR OUTSIDE GLAZING

STEEL REINFORCING

BACKPAN HORIZONTAL

BACKPAN VERTICAL

BACKPAN SSG VERTICAL

ADMD050

16

1600 WALL SYSTEMTM5

DECEMBER, 2013

WIND LOAD / DEADLOAD CHARTS

EC 97911-053

DEADLOAD CHARTS

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an
intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4"
(6.35) thick glass supported on two setting blocks placed at the loading points shown.

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4"
above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress
and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted
curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures
of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A
4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these
curves, contact your Kawneer representative for additional information.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

WIND LOAD CHARTS

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

WIND LOAD CHARTS (TYPE "B" SCREW SPLINE)


A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

TWIN SPAN

METERS

1.5

.5

16

13

4.5

12

2.5

8
7

6" (154.4)

10

2
6
5

1.5

3.5
11
10

2.5

E D

3-3/4" (95.3)

C
D

MULLION HEIGHT IN FEET

3.5

METERS

11

13

METERS

12

1.5

4
1

3
2

0.5

I = 8.085 (336.52 x 104)


S = 2.692 (44.11 x 103)

0.5

166036
1

166040
0

TWIN SPAN

METERS
.5

I = 3.115 (129.66 x 104)


S = 1.633 (26.76 x 103)

MULLION CENTERS IN FEET

SINGLE SPAN

METERS

1.5

.5

1.5

16

16
15

13

12

10

2.5

8
7

2
6
5

7-1/2" (190.5)

METERS

1.5

3.5
11

10
9

E D

2.5

8
7

2
6
5

1.5

4
1

3
2

MULLION CENTERS IN FEET

kawneer.com

0.5

166013
0

0.5

I = 15.271 (635.63 x 104)


S = 4.139 (67.83 x 103)

166018
0

MULLION CENTERS IN FEET

ADMD050

5-1/4" (133.4)

3.5

METERS

11

C
MULLION HEIGHT IN FEET

12

4.5

14

13

15

4.5

14

MULLION HEIGHT IN FEET

14

MULLION CENTERS IN FEET

Kawneer Company, Inc., 2013

1.5

15

4.5

14

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

16

15

MULLION HEIGHT IN FEET

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

METERS
.5

17

I = 7.342 (305.60 x 104)


S = 2.759 (45.21 x 103)

1600 WALL SYSTEMTM5

DECEMBER, 2013

WIND LOAD CHARTS (TYPE "A" SCREW SPLINE)

EC 97911-053

A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

METERS

1.5

.5

16
15

4.5

14
4

12

C
D
E

2.5

8
7

6" (154.4)

METERS

10

2
6
5

1.5

3.5
11
10

E D

2.5

2
6
5

3-3/4" (95.3)

3.5

11

13

METERS

12

MULLION HEIGHT IN FEET

13

1.5

4
1

3
2

0.5

I = 7.553 (314.38 x 10 )
S = 2.519 (41.28 x 103)
4

MULLION CENTERS IN FEET

0.5

165016 & 166033


0

165016 & 166039


0

I = 3.276 (136.36 x 104)


S = 1.739 (28.50 x 103)

SINGLE SPAN

METERS
.5

MULLION CENTERS IN FEET

SINGLE SPAN

METERS

1.5

.5

16

1.5

16

15

7
2
6
5

7-1/2" (190.5)

2.5

METERS

1.5

3.5
11

10

E D

2.5

8
7

2
6
5

1.5

4
1

3
2

MULLION CENTERS IN FEET

0.5

166010 & 166011


0

0.5

I = 14.344 (597.04 x 10 )
S = 3.687 (60.42 x 103)
4

166010 & 166015


0

MULLION CENTERS IN FEET

ADMD050

5-1/4" (133.4)

MULLION HEIGHT IN FEET

10

12
3.5

11

13

METERS

12

4.5

14

13

15

4.5

14

MULLION HEIGHT IN FEET

1.5

15

4.5

14

MULLION HEIGHT IN FEET

16

I = 7.571 (315.13 x 104)


S = 2.868 (47.00 x 103)

kawneer.com

Kawneer Company, Inc., 2013

METERS
.5

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

SINGLE SPAN

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

18

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

WIND LOAD CHARTS (SPLIT MULLION)


A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

TWIN SPAN

METERS

1.5

.5

16

2
9

28

8.5

27

12

2.5

8
7

2
6
5

1.5

MULLION HEIGHT IN FEET

METERS

MULLION HEIGHT
EQUAL
EQUAL

10

6" (154.4)

11

MULLION HEIGHT

3.5

26

7.5

24
23

22

E D
C

21

6.5

20

19
5.5

18
1

3
2

17

15

166080 & 166081


1

16

0.5

I = 8.172 (340.14 x 104)


S = 2.423 (39.71 x 103)

4.5
0

TWIN SPAN

METERS
.5

MULLION CENTERS IN FEET

SINGLE SPAN

METERS

1.5

.5

16

1.5

30

15

29

4.5

14

28
4

13

2.5

7
2
6
5

1.5

4
1

MULLION HEIGHT IN FEET

E D

MULLION HEIGHT
EQUAL
EQUAL

3-3/4" (95.3)

METERS

MULLION HEIGHT

11

26

3.5

10

8.5

27

12

MULLION HEIGHT IN FEET

26

25

7.5

24
23
22
6.5

21
20

19

18

E D

17

166084 & 166085


0

MULLION CENTERS IN FEET

kawneer.com

5.5

C
5

16

0.5

I = 4.031 (167.78 x 104)


S = 2.063 (33.81 x 103)

ADMD050

15

4.5
0

MULLION CENTERS IN FEET

METERS

13

METERS

14

MULLION CENTERS IN FEET

Kawneer Company, Inc., 2013

1.5

29

4.5

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

30

15

MULLION HEIGHT IN FEET

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

METERS
.5

19

1600 WALL SYSTEMTM5

DECEMBER, 2013

WIND LOAD CHARTS (SPLIT MULLION)

EC 97911-053

A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

TWIN SPAN
METERS

1.5

.5

1.5

30
9
29

4.5

28

14
4

13

8
7

2
6
5

1.5

MULLION HEIGHT IN FEET

2.5

MULLION HEIGHT
EQUAL
EQUAL

7-1/2" (190.5)

MULLION HEIGHT

10

METERS

26
3.5

11

8.5

27

12

MULLION HEIGHT IN FEET

26

7.5

24

E D

23

22
6.5

21
20

19
5.5

18

4
1

3
2

17

15

166082 & 166083


1

16

0.5

I = 15.977 (665.01 x 10 )
S = 3.696 (60.57 x 103)

4.5
0

MULLION CENTERS IN FEET

TWIN SPAN

METERS
1

MULLION CENTERS IN FEET

SINGLE SPAN
.5

METERS

15

METERS

1.5

.5

1.5

30

16

9
29

4.5

3.5

7
2
6
5

1.5

MULLION CENTERS IN FEET

7.5

23

E D

22

6.5

21
20

19
5.5

16

166086 & 166087


1

24

17

0.5

26

18

MULLION HEIGHT IN FEET

2.5

MULLION HEIGHT
EQUAL
EQUAL

26

E D C

10

8.5

27

5-1/4" (133.4)

11

MULLION HEIGHT

12

METERS

13

MULLION HEIGHT IN FEET

28

14

METERS

15

I = 9.049 (376.65 x 104)


S = 3.331 (54.59 x 103)

ADMD050

15

4.5
0

MULLION CENTERS IN FEET

kawneer.com

Kawneer Company, Inc., 2013

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

METERS
.5
16

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

20

DECEMBER, 2013

1600 WALL SYSTEMTM5

EC 97911-053

WIND LOAD CHARTS (SHEAR BLOCK)


A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

TWIN SPAN

METERS

1.5

.5

1.5

2
9

29

4.5

28

14
4

13

2.5

8
7

2
6
5

1.5

MULLION HEIGHT IN FEET

C
D

METERS

6" (154.4)

MULLION HEIGHT
EQUAL
EQUAL

3.5

11
10

26

MULLION HEIGHT

12

8.5

27

26

7.5

24

23

22

21

6.5

20

19
5.5

18

4
1

3
2

17

15

166038
2

16

0.5

I = 7.606 (316.59 x 104)


S = 2.654 (43.49 x 103)

MULLION CENTERS IN FEET

4.5
0

TWIN SPAN

METERS
1

MULLION CENTERS IN FEET

SINGLE SPAN
.5

METERS

15

METERS

1.5

.5

1.5

30

16

9
29

4.5

28

14
4

13

26

2.5

E D

6
5

1.5

4
1

3
2

METERS

3-3/4" (95.3)

10

MULLION HEIGHT

11

MULLION HEIGHT
EQUAL
EQUAL

3.5

MULLION CENTERS IN FEET

kawneer.com

7.5

24
23

22
6.5

21

20

19
5.5

17

16

166041
0

26

18

0.5

MULLION HEIGHT IN FEET

12

MULLION HEIGHT IN FEET

8.5

27

I = 2.973 (123.75 x 104)


S = 1.567 (25.68 x 103)

ADMD050

15

E D
0

4.5

C
5

MULLION CENTERS IN FEET

METERS

15

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

30

16

MULLION HEIGHT IN FEET

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

METERS
.5

21

1600 WALL SYSTEMTM5

DECEMBER, 2013

WIND LOAD CHARTS (SHEAR BLOCK)

EC 97911-053

A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

TWIN SPAN

METERS
.5

METERS

1.5

.5

1.5

30

16

14

10
9

2.5

8
7

METERS

2
6
5

7-1/2" (190.5)

MULLION HEIGHT
EQUAL
EQUAL

3.5

1.5

MULLION HEIGHT IN FEET

26

11

8.5

27

MULLION HEIGHT

12

28

13

MULLION HEIGHT IN FEET

29

4.5

26

7.5

24

23

22

21

6.5

20

19

5.5

18

4
1

3
2

17

15

166005
1

16

0.5

METERS

15

I = 14.042 (584.47 x 10 )
S = 3.813 (62.48 x 103)
4

MULLION CENTERS IN FEET

4.5
0

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

22

MULLION CENTERS IN FEET

METERS
.5

1.5

30
9
29
28

8.5

27

23

22
6.5

21

20

19
18

5.5

17

16

15

4.5
0

7-1/2" (190.5)

7.5

24

METERS

MULLION HEIGHT IN FEET

26

MULLION HEIGHT

26

MULLION CENTERS IN FEET

166005 W/162301/302/303
Ia = 14.042 (584.47 x 104)
Sa = 3.813 (62.48 x 103)
Is = 9.347 (389.05 x 104)
Ss = 4.099 (67.17 x 103)

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

SINGLE SPAN

DECEMBER, 2013

1600 WALL SYSTEMTM5

EC 97911-053

WIND LOAD CHARTS (SHEAR BLOCK)


A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

TWIN SPAN

METERS

1.5

.5

29

4.5

28

14
4

26

E D

2.5

8
7

METERS

10

2
6
5

1.5

MULLION HEIGHT
EQUAL
EQUAL

5-1/4" (133.4)

11

MULLION HEIGHT

3.5

166008
3

I = 6.639 (276.34 x 104)


S = 2.507 (41.08 x 103)

SINGLE SPAN
METERS
.5

1.5

30
9
29
28

8.5

27

7.5

23

22
6.5

21
20

19

METERS

24

5-1/4" (133.4)

26

MULLION HEIGHT

26

A
5.5

18

17

16
15
0

4.5

E D
5

MULLION CENTERS IN FEET

kawneer.com

23

22

6.5

21
20

19

E D

5.5

16

1
2

7.5

24

17

0.5

26

18

MULLION HEIGHT IN FEET

12

MULLION HEIGHT IN FEET

8.5

27

166008 W/162301/302/303
Ia = 6.639 (276.34 x 104)
Sa = 2.507 (41.08 x 103)
Is = 9.347 (389.05 x 104)
Ss = 4.099 (67.17 x 103)

ADMD050

15

4.5
0

MULLION CENTERS IN FEET

METERS

13

MULLION CENTERS IN FEET

Kawneer Company, Inc., 2013

1.5

9
15

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

30

16

MULLION HEIGHT IN FEET

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

METERS
.5

23

1600 WALL SYSTEMTM5

DECEMBER, 2013

WIND LOAD CHARTS (SHEAR BLOCK)

EC 97911-053

A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)

SINGLE SPAN

TWIN SPAN

METERS
.5

METERS

1.5

.5

1.5

30

16

9
29

4.5

28

14

9
2.5

8
7

2
6
5

1.5

23

22
6.5

21

E D

20

19
5.5

15

166017
2

7.5

16

1
1

24

17

0.5

26

18

MULLION HEIGHT IN FEET

E D

MULLION HEIGHT
EQUAL
EQUAL

10

3.5

5-1/4" (133.4)

11

26

METERS

MULLION HEIGHT IN FEET

12

8.5

27

MULLION HEIGHT

13

METERS

15

I = 8.292 (345.14 x 10 )
S = 3.046 (49.91 x 103)
4

MULLION CENTERS IN FEET

4.5
0

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

24

MULLION CENTERS IN FEET

METERS
.5

1.5

30
9
29
28

8.5

27

23

22
6.5

21
20

19
18

5.5

17

16

E D

15
0

5-1/4" (133.4)

7.5

24

METERS

MULLION HEIGHT IN FEET

26

MULLION HEIGHT

26

4.5
6

MULLION CENTERS IN FEET

166017 W/162301/302/303
Ia = 8.292 (345.14 x 104)
Sa = 3.046 (49.91 x 103)
Is = 9.347 (389.05 x 104)
Ss = 4.099 (67.17 x 103)

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

SINGLE SPAN

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

25

DEADLOAD CHARTS

6" (152.4)

6" (152.4)

166035

METERS
.5

METERS

1.5

.5

A = 1/4" Glass 1/8 Point Loading


B = 1/4" Glass 1/4 Point Loading

13

12

10

3.5

B = 1" Glass - 1/8 Point Loading


C = 1" Glass - 1/4 Point Loading

11
10

GLASS HEIGHT IN FEET

7
2
6

C B

METERS

2.5

1.5

4
1

3
2

9
2.5

8
7

2
6
5

C B

1.5

3
2

0.5

0.5

1
1

SPAN IN FEET

7-1/2" (190.5)

7-1/2" (190.5)

166007

166002

METERS

METERS
1

1.5

A = 1/4" Glass 1/8 Point Loading


B = 1/4" Glass 1/4 Point Loading

13
12

2
6
5

METERS

GLASS HEIGHT IN FEET

Kawneer Company, Inc., 2013

2.5

1.5

4
1

3
2

3.5
11
10

9
8

1.5

12

C B

13

B = 1" Glass - 1/8 Point Loading


C = 1" Glass - 1/4 Point Loading

3.5
11
10

.5

GLASS HEIGHT IN FEET

.5

9
2.5

8
7

C B

1.5

4
1

3
2

0.5

0.5

1
0

SPAN IN FEET

SPAN IN FEET

ADMD050

METERS

kawneer.com

METERS

3.5
11

SPAN IN FEET

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

1.5

13

12

GLASS HEIGHT IN FEET

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

166031

1600 WALL SYSTEMTM5

26

DECEMBER, 2013

THERMAL CHARTS

EC 97911-053

Project Specific U-factor


Example Calculation
(Based on single bay of Curtain Wall/Window Wall)

6'-0"

D.L.O.

SPANDREL

9'-0"

D.L.O.

VISION

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

5'-0"
D.L.O.

Vision Area

Example Glass U-factor

= 0.48 Btu/(ft2 h F)

Vision Area

= 5(9 + 8 + 4) = 105.0 ft2


Total Area (Vision)
= 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2


Percentage of Vision Glass
= (Vision Area Total Area)100


= (105.0 113.2)100 = 93%

Spandrel Area

Example Spandrel R-value

= 15 (ft2 h F)/Btu

Spandrel Area

= 5(6 + 3) = 45.0 ft2

Total Area (Spandrel)

= 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2

Percent of Spandrel

= (Spandrel Area Total Area)100


= (49.0 49.6)100 = 91%

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

VISION

2-1/2" Typ.

3'-0"
D.L.O.
4'-0"
D.L.O.

VISION

31'-3"

SPANDREL

8'-0"
D.L.O.

2-1/2" Typ.

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

27

THERMAL CHARTS

Vision Area Chart

System U-factor vs Percent of Vision Area

(N

0.70

E IGN
PL S
M E
A D
EX OR
F
T
O

COG
U-factor

0.53
0.50

0.40

0.30

0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20

0.60

Btu
hft 2F
System U-factor

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

0.80

93%

0.20
95

85

90

75

80

70

Vision Area / Total Area (%)

Based on a single curtain wall bay of 93% vision glass and center
of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(hft 2F)

System U-factor vs Percent of Spandrel Area


Spandrel
R-value

E IGN
PL S
M E
A D
EX OR
F
T
O

3.00

4.00

Kawneer Company, Inc., 2013

5.00

0.30

0.21
0.20

0.10

91%

95

0.40

11.00
15.00
19.00
30.00

0.50

Btu
hft 2F
System U-factor

2.00

0.60

(N

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Spandrel Area Chart

90

85

80

75

70

Spandrel Area / Total Area (%)

Based on a single curtain wall bay of 91% spandrel and center of


spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(hft 2F)

kawneer.com

ADMD050

System U-Factor for Vision Glass

ADMD050

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

THERMAL CHARTS (CAPTURED)

Vision Area / Total Area (%)

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

1600 WALL SYSTEMTM5

kawneer.com

Kawneer Company, Inc., 2013

COG
U-factor

System U-Factor (Btu/hft2F)

28
DECEMBER, 2013
EC 97911-053

Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

EC 97911-053

0.60

0.55

0.50

kawneer.com

Spandrel
R-Value
0.45

2.00

0.40

3.00

0.35

4.00

0.30

5.00

95
0.25

0.20

11.00

0.15

15.00
19.00
30.00

0.10

90
85
80

Spandrel Area / Total Area (%)

ADMD050
75
70
0.05

System U-Factor (Btu/hft2F)

DECEMBER, 2013

1600 WALL SYSTEMTM5


THERMAL CHARTS (CAPTURED)

Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.

System U-Factors for Spandrel Glass


0.75

0.70

0.65

29

Vision Area / Total Area (%)

COG
VT

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Ares / Total Area (%)

Charts are generated per AAMA 507.

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

THERMAL CHARTS (CAPTURED)

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 WALL SYSTEMTM5

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

System SHGC

COG
SHGC

System VT

30
DECEMBER, 2013
EC 97911-053

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Charts are generated per AAMA 507.

Kawneer Company, Inc., 2013

COG
U-factor

kawneer.com

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

System U-Factor (Btu/hft2F)

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

DECEMBER, 2013

1600 WALL SYSTEMTM5

EC 97911-053
THERMAL CHARTS (SSG)

Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.

System U-Factor for Vision Glass

Vision Area / Total Area (%)

ADMD050

31

THERMAL CHARTS (SSG)

System U-Factors for Spandrel Glass


0.70

0.65

0.60

0.50

Spandrel
R-Value
0.45

2.00

0.40

0.35

3.00

0.30

4.00

5.00

0.25

0.20

11.00
15.00
19.00
30.00

90
85
80

ADMD050
75

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 WALL SYSTEMTM5

kawneer.com

Kawneer Company, Inc., 2013

95

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

0.55

System U-Factor (Btu/hft2F)

32
DECEMBER, 2013
EC 97911-053

Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.

0.15

0.10

70
0.05

Spandrel Area / Total Area (%)

System VT

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

System SHGC

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

DECEMBER, 2013

COG
SHGC

kawneer.com

1600 WALL SYSTEMTM5

EC 97911-053

Vision Ares / Total Area (%)

Charts are generated per AAMA 507.

ADMD050

33

THERMAL CHARTS (SSG)

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Vision Area / Total Area (%)

Charts are generated per AAMA 507.

System Visible Transmittance (VT) vs Percent of Vision Area

COG
VT

1600 WALL SYSTEMTM5

DECEMBER, 2013

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

EC 97911-053

Overall U-Factor 4

0.48

0.65

0.46

0.63

0.44

0.61

0.42

0.60

0.40

0.58

0.38

0.57

0.36

0.55

0.34

0.54

0.32

0.52

0.30

0.51

0.28

0.49

0.26

0.47

0.24

0.46

0.22

0.44

0.20

0.43

SHGC Matrix 2 (CAPTURED)

Visible Transmittance 2 (CAPTURED)

Glass SHGC 3

Overall SHGC 4

Glass VT 3

Overall VT 4

0.90

0.80

0.90

0.78

0.85

0.76

0.85

0.74

0.80

0.72

0.80

0.69

0.75

0.67

0.75

0.65

0.70

0.63

0.70

0.61

0.65

0.59

0.65

0.56

0.60

0.54

0.60

0.52

0.55

0.50

0.55

0.48

0.50

0.46

0.50

0.43

0.45

0.41

0.45

0.39

0.40

0.37

0.40

0.35

0.35

0.33

0.35

0.30

0.30

0.28

0.30

0.26

0.25

0.24

0.25

0.22

0.20

0.20

0.20

0.17

NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Glass U-Factor 3

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

Thermal Transmittance1 (BTU/h ft 2 F) (CAPTURED)

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

34

1600 WALL SYSTEMTM5

DECEMBER, 2013
EC 97911-053

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Glass U-Factor 3

Overall U-Factor 4

0.48

0.58

0.46

0.56

0.44

0.55

0.42

0.53

0.40

0.51

0.38

0.50

0.36

0.48

0.34

0.46

0.32

0.45

0.30

0.43

0.28

0.42

0.26

0.40

0.24

0.38

0.22

0.37

0.20

0.35

SHGC Matrix 2 (SSG)

Visible Transmittance 2 (SSG)

Glass SHGC 3

Overall SHGC 4

Glass VT 3

Overall VT 4

0.90

0.84

0.90

0.79

0.85

0.79

0.85

0.74

0.80

0.75

0.80

0.70

0.75

0.71

0.75

0.66

0.70

0.66

0.70

0.61

0.65

0.62

0.65

0.57

0.60

0.57

0.60

0.52

0.55

0.53

0.55

0.48

0.50

0.49

0.50

0.44

0.45

0.44

0.45

0.39

0.40

0.40

0.40

0.35

0.35

0.36

0.35

0.31

0.30

0.31

0.30

0.26

0.25

0.27

0.25

0.22

0.20

0.22

0.20

0.17

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

Thermal Transmittance1 (BTU/h ft 2 F) (SSG)

NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").

kawneer.com

ADMD050

35

Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.

1600 WALL SYSTEMTM5

BLANK PAGE

ADMD050

kawneer.com

Kawneer Company, Inc., 2013

Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.

36
DECEMBER, 2013
EC 97911-053