You are on page 1of 16

4/13/2014

Water Pipe Networks


First Tutorial in WaterCad
Introduction and Data Entry
By Mohamed Elgamal

WATERCAD
GETTING STARTED

4/13/2014

Icons of WaterCad

WaterCAD Features

Steady-State Analysis
SteadyTRex Extract Elevations from multiple digital formats
Extended--Period Simulation (EPS)
Extended
Constituent--Concentration Analysis
Constituent
Water--Age Analysis
Water
Variable--Speed Pumping
Variable
Pressure--Dependent Demands
Pressure
Scenario Modeling

4/13/2014

NETWORK PRESENTATION
AND MAIN ELEMENTS
Network and Transmission Lines are
Represented in WaterCad as Links and Nodes:
Link
Node

Node

Nodes Represent

Links Represent

Junctions

Valves

Tanks

Pumps

Pipes

Reservoirs

Important Valves In WaterCad


Valve
Isolation Valve
Air Valve

Symbol in
WaterCad

Application
To isolate part of the
system
To release air trapped in the
system

Check Valve

To prevent backflow

Flow Control
Valve (FCV)
Pressure Reducing
Valve (PRV)

To limit the flow to a


maximum value

Pressure Sustaining
Valve (PSV)

To limit the d/s pressure to a


maximum value
To limit the u/s pressure to
drop below a minimum
value

4/13/2014

How To Resolve the Drawing


Haziness Bug in WaterCad
For Window XP:
Before browsing shoe hidden files and folders of windows (tools-folder optionview-show hidden files and folders)
1-Browse to
C:\Documents and Settings\XXXXXXX\Application Data\Bentley\ WaterGEMS
\8\
Where XXXXX is your user name.
You must close the program before you continue.
2-Open the( Haestad.Framework.Application.GlobalUserOptions.XML) file with
Notepad. Search for the word allowpartialredraw in the file, change its setting
from true to false then press Ctrl+S to save the file.
Done

How To Resolve the Drawing


Haziness Bug in WaterCad
For Window 7:
Before browsing shoe hidden files and folders of windows (tools-folder optionview-show hidden files and folders)
1-Browse to
C:\users\username\AppData\Roaming\Bentley\WaterGEMS\8\
Haestad.Framework.Application.GlobalUserOptions.xml

You must close the program before you continue.


2-Open the( Haestad.Framework.Application.GlobalUserOptions.XML) file with
Notepad. Search for the word allowpartialredraw in the file, change its setting
from true to false then press Ctrl+S to save the file.
Done

4/13/2014

First Tutorial in WaterCad


Objectives
The purpose of this Tutorial is to train the trainees
how to:
-Construct a new WaterCad model,
-Manually enter all the required data in the model,
-Run the model and clear the model errors (if any),
-Investigate the model results,
-Carryout sensitivity analysis.

First Tutorial in WaterCad


Given the water distribution system shown in the below
Figure, it is requested to construct a WaterCad model
and to run the model assuming all pipes roughness of
C=100 which corresponds to 10-years old Cast Iron.

C = 100 (all pipes);

4/13/2014

Steps for WaterCad Model


1. Start a new Project:
File New

Steps for WaterCad Model


2. Change Units to SI System:
Tools Options Units Reset Defaults
to System International

4/13/2014

Steps for WaterCad Model


3. Use Hazen William for friction head losses
calculations:
-Click Calculation Option Button
-Select Steady State Solver;
-Click Base Calculation Option;
-For Friction Method: Select Hazen William.

First Tutorial in WaterCad


4. Start Drawing Your Network: System Layout
Right Click the mouse to select different elements

Draw the whole Network


using the same labels

4/13/2014

First Tutorial in WaterCad


4. Start Drawing Your Network: System Layout
Right Click the mouse to select different elements

Draw the whole Network


using the same labels

How can I change the labels and


node numbering?

4/13/2014

Changing Labels and Node


Numbering in WaterCad
WaterCad uses automatic sequential numbering. If user
deleted any element by mistake, WaterCad automatically will
skip the number of the deleted item and start numbering
afterward.
In order to start the automatic numbering from a certain
number you like, do the following:

Tools Options Labeling


Change the next number you
like WaterCad to begin with.

First Tutorial in WaterCad


5. Enter Junction Data, Using Flex Table
Click the arrow of the Flex Table Icon and select
Junction
Enter Junction Elevations

4/13/2014

First Tutorial in WaterCad


6. Enter Pipe Data, Using Flex Table
Click the arrow of the Flex Table Icon and select
Pipe
Enter Pipe Diameter & C

First Tutorial in WaterCad


Right click over Has User Defined Length and
Select Global Edit Check Value OK

Enter Pipe
Lengths

10

4/13/2014

First Tutorial in WaterCad


7. Enter Junction Demand Data:
Tools Demand Control Center Click Yes
Right Click over
Demand Select
Units and Formatting
Select l/s

Enter Demand Values

First Tutorial in WaterCad


8. Enter Tank Data: Double Click Tank Element

Max. Elev.
G. Elev.

Initial Elev.
Min. Elev.

Base Elev.

11

4/13/2014

First Tutorial in WaterCad


9. Enter Reservoir Data: Double Click Reservoir Element
Enter Reservoir Water Elev.

Water Elev.

Remember that Reservoir in WaterCad means


unlimited Water Storage Facility i.e. water elevation
will not change due to continuous supply.

First Tutorial in WaterCad


10. Enter Pump Data:

Double Click Pump Element

Enter Pump Center Elev.


Pump Centre Elev.

Select Pump Definition


Edit Pump Definition
Pump Definition Type: Stand. (3 Point)
Enter Q &H data of pump

12

4/13/2014

First Tutorial in WaterCad


Run the Model
Correct all errors
Explore Results
1. Investigate Flow direction;
2. Is the tank in filling or emptying process? .

First Tutorial in WaterCad


Explore pipe velocity Table and the rate of head
lost

If the head loss rate is greater than 7m/km, change


the pipe sizes accordingly
Re-Run again

13

4/13/2014

First Tutorial in WaterCad


Reset pipe diameter to initial value
Plot the HGL and Profile through
the shown paths

First Tutorial in WaterCad


Carryout sensitivity analysis:
By changing C.

What will be the effect on:


- Pumping head and operating point;
- Flow distribution

14

4/13/2014

Effect of Changing C
C = 100

C = 130

First Tutorial in WaterCad


Close pipes P-13 and investigate the changes.
Close pipes P-14 and investigate the changes.

15

4/13/2014

First Tutorial in WaterCad


Color Code the Pipes as per their velocity
magnitude

16

You might also like