You are on page 1of 41

BOM for Electrical Installation wo

SR. No.

a
b
c
d
1.1

1.2

1.3

1.4

1.5

1.6

1.7

1.8

1.9

1.10

1.11

Notes
a
b
c
d
e
f
g
h
i

2.1

2.2
2.3

2.4
2.5
2.6
2.7
2.8
2.5
2.5.1
2.5.2
2.5.3
2.5.4
2.5.5
2.5.6
2.5.7
2.5.8

a
3.2

Notes
a
b
c
4.1
4.3

4.5
4.6

Notes:
a
b
c
d
e
f
g
h

4.1

4.2
4.3

4.4
4.5
4.6

4.7

4.7

Notes:
a
b
c
d
e

5.1
5.2
5.3
5.4

a
b
c
d
e
f
g

7.1
7.3
7.4
7.5
7.6
7.7
7.8

7.9
7.10
7.11
7.12

BOM for Electrical Installation works


DESCRIPTION OF MATERIAL
Make of Material

MCCB's - Schneider Compact(for comm. MCCB)/ABB/Siemens(VL)/ L&T


MCB's and DB's - Legrand/Schneider/ABB
Wires - Polycab/Finolex
Cables - Polycab/ Ravin/Terracom
Termination - Dowells/Jainson
CT's - Kappa / L&T
Selector Switch - Kaycee / L&T / BCH
Indicating Lamps - Seimens / L&T / Teknik

PART - I : PANELS AND DISTRIBUTION BOARDS.

Supply, Installation, Testing and Commisioning of Following Panels and DB's with proper gauge MS sheet and shall comply with
Main Panels and Sub Panels will have standard meters and phase indicators.
All BusBar will be of Alluminium
All Panels shall be of IP-42 Protection
DC LT Panel ( As per the SLD attached )
Incomer
1600A 4P ACB--- 2 Nos. (one from Main LT-PNL & one for Mobile DG)- with TVSS of 250 KA with Surge
counter.
Including , Phase indicators, ON, OFF and Trip Indicators, Load Managers
Bus Coupler
1600A 4P ACB--- 1 Nos.
With Electrical/ mechanical Interlocking among incomers & buscouplers.
Bus Bar
1600A 4P, Al Busbar, with Current Density not more than 0.8A/sqmm.
Outgoings
630A 4P MCCB--- 2 Nos. (for 300kVA UPS I/P PNL & Spare)
315A 4P MCCB--- 2 Nos.( PAC PNL-Gr fl & Spare)
250A 4P MCCB--- 2Nos.(1Nos. SMPS & Spare)
1000A TPN ACB--- 2 Nos. (PAC Panel first floor & Spare)
63A 4P MCB--- 10 Nos. (LDB, RDB, 10kVA UPS & 7 spares)
UPS I/P Panel 300kVA UPS Set ( As per the SLD attached )
Incomer
630A 4P MCCB--- 1No.
Including , Phase indicators, ON, OFF and Trip Indicator, Load Managers
Bus Bar
630A 4P CU Busbar, with Current Density not more than 1.5A/sqmm.
Outgoings

315A 4P MCCB--- 2 Nos.(150kVA NXr UPS Module)


UPS O/P Panel 300kVA UPS Set ( As per the SLD attached )
Incomer
315A 4P MCCB--- 2No. (without Interlocking
Including , Phase indicators, ON, OFF and Trip Indicator.
Bus Bar
630A 4P CU Busbar, with Current Density not more than 1.5A/sqmm.
Outgoings
315A 4P MCCB--- 3 Nos.(2Nos. PDU of 150kVA & spare)

PAC Panel for Server Room ( As per the SLD attached )


Incomer
1000A TPN ACB--- 1No.
Including , Phase indicators, ON, OFF and Trip Indicator, Load Managers
Bus Bar
1000A TPN CU Busbar, with Current Density not more than 1.5A/sqmm.
Outgoings
125A TPN MCCB--- 7 Nos.(6 PAC & 1 spare)
63A TPN MCB -- 3Nos.(spares)
32A DP MCB -- 4Nos. (2Nos. Split AC (in OMCR & Lobby & 2 spares)
PAC Panel for Electrical Room ( As per the SLD attached )
Incomer
315A TPN MCCB--- 1No.
Including , Phase indicators, ON, OFF and Trip Indicators. Load Managers
Bus Bar
315A TPN CU Busbar, with Current Density not more than 1.5A/sqmm.
Outgoings
63A TPN MCCB---6 Nos. (5 PAC & 1 spare)
63A DP MCB - 6 Nos. (Spare)

150 kVA PDU- With Isolation Transformer ( As per the SLD attached )
Incomer
315A 4P MCCB--- 1No.
Including , Phase indicators, ON, OFF and Trip Indicators & Load Manager
Outgoings
16A DP MCB--- 36 Nos. (30Racks + 6 spares)
32A DP MCB--- 6 Nos. (Spares)
63A DP MCB--- 6 Nos. (Spares)
K-13 Isolation Transformer DYn11, 415V/415V, with Soft Starter, TVSS
LPDB for lighting distribution

6 way TPN DB single door


63A TPN MCB 1no.incoming & ELMCB
10A SP MCB - 18Nos on outgoings. Equally distributed on three phases.
RPDB for Raw Power distribution
6 way TPN DB single door
63A TPN MCB 1no. Incoming
16A SP MCB - 12Nos on outgoings. Equally distributed on three phases.

10 kVA UPS DB for UPS Power distribution (BMS Load + Emergency Ltg)
6 way DB single door
63A DP MCB 1no. Incoming
10 SP MCB - 8Nos on outgoings.

125A Automatic Transfer Switch for PAC Units in Server room


125A ATS with enclosure & with bypass arrangement
63A Automatic Transfer Switch for PAC Units in Electrical room
63A ATS with enclosure & with bypass arrangement
Total Part - I

PART - II : CABLES, BBT AND TERMINATION.


Brands of cables: Universal, gloster, polycab, nicco
The rates for all item of work shall include :-

Effecting proper and adequate connections at terminations.


Ensuring that provision is left in building components and trenches as the work proceeds for incorporation of cable supports a
Providing all fixing accessories such as clamping devices, Tie's, nuts and bolts, screws where laid in trenches or trays.(Not to
Providing proper supports for cable terminal boxes .
Providing heavy duty copper lugs, insulation tape etc. at joints and terminations.
All fixing accessories such as GI saddles, screws, raw plugs, suitable size Anchor Fasteners etc.
Wire/Cable Joint by crimping type lugs.
Cutting chases, holes and making good the same wherever required. ( Not Valid for any Concrete Slab)
Testing of the Cables in the Manufactures works and providing test certificates with the handover documents is the sole respon
Sandwitch Type Alluminium Bus ducting from Main Panel, DG panel to DC LT Panels. 1600A, 4P,
suitable for indoor & Outdoor application

3.5C x 300 Sq.mm Al Arm, FRLS


1C x 150Sq.mm Cu flex FRLS
1C x 120 Sq.mm Cu flex FRLS

3.5C x 240 Sq.mm Cu Arm FRLS


3.5C X 35 Sq.mm Cu Arm FRLS
4C x 10 Sq.mm Cu Arm FRLS
3C X 6 Sq.mm Cu flex FRLS
4CX 6 sqmm Cu arm FRLS
Terminations for Cable
3.5C x 300 Sq.mm Al Arm
1C x 150 Sq.mm Cu flex
1C x 120 Sq.mm Cu flex
3.5C X 240 Sq.mm Cu Arm
3.5C x 35 Sq.mm Cu Arm
4C x 10 Sq.mm Cu Arm
3C x 4 Sq.mm Cu flex
4C x 6 Sq.mm Cu arm
Total Part - II

PART-III : MOBILE SOCKETS AND STRAIGHT PLUGS.


All the mobile sockets and straight plugs should be of IP 44 type and of approved make.
32A DP+E Mobile Socket with plug
Total Part - III

PART - IV :CABLE TRAYS (of Pre Babricated, Standard Make, Extendabale)


The rates for all item of work shall include :Supply and Installation with all nescessary supports and hardware.
The work should be carreid out as specified in the specification sheet.
Colour of the Trays has to be confirmed by the customer.
70mm x 300 mm wide perforated poweder coated black color (Power Tray)
70mm x 450 mm wide perforated poweder coated black colour (Power Tray)

100mm X 100mm OFC Tray


75mm X 600mm Ladder cable tray in electrical room (Power Tray)
Total Part - IV

PART-V : POINT WIRING AND CONDUITING WORK

These notes shall apply to all the relevant wiring items described in the schedule of items given below :All
circuit
wiring,
sub wiring
mains shall
wiringbeshall
done using
PVC conduits
minimum
thickness
and shall
All points
switchwiring,
boards
under
the point
the be
standard
boxesrigid
available
and theofsame
shall1.6mm
be suitable
for concealed
practice and should be suitable to accommodate
The entire wiring shall have continuous 2.5 sq.mm. approved make FR Copper conductor earth wire for earth continuity havin
The point wiring shall comply to IS 732.
The entire work has to be carried out under the direct supervision of PMC/Prime Contractor.
All materials under this schedule shall deemed to be included by the Contractor in his scope.
The
entirewiring
work to
be carried
out
as perofthe
specifications
laidlength
down from
in thedistribution
tenders, approved
drawings,and
asthe
perpoint
final and
dire
The point
shall
include
wiring
light
outlet of any
board via
switch or to
of 1.8 mm and using wires as specified below of approved

Primary point from MCB/ 5A Switch


with 3 x 2.5 sqmm wire
Secondary Point Looped from item 4.1
Primary point for Raw power with
3 x 4sqmm wire
Secondary point looped from item 4.3
5A Switch with plate and back box
5/15A Socket + 15 A switch with
all accessareis
3 nos.5 pin 5 A socket + 15 A switch with
all accessareis
63 Amps socket
all accessareis
Total Part - V

PART-VI : LIGHTING FIXTURES & AND ACCESSORIES.

The rates for lighting fixtures and fans shall include all accessories and supply of all materials that may be required to make t
All the fixtures shall be suitable for single phase, 50 cycles, 230 Volts, AC supply system.
All light fixtures shall be provided with Electronic ballast as described in the schedule.
All fixtures shall be factory wired with copper conductor wires.
All fixtures shall be supplied with fluorescent lamps/incandescent bulbs or any other special type bulbs
All the fixtures shall be quoted of approved make only.

2' x 2' Ceiling suspended LED light fixtures


2' x 2' Direct Mount LED light fixtures
9 Watt LED Spot Light Fixtures
Motion Sensor to control lighting fixtures in rows & passages

Total Part - VI

PART - VII : EARTHING AND EARTHING STRIPS.

All earth pits shall be as per IS 3043 with latest amendments.


Earthing stations should contain relevant grade of charcoal/coke and salt packed around the earth plate/earth pipe as called
Earthing shall be done at indicted location by the Consultants. The minimum distance between the two earth station shall be
An earth ring with relevant earth test terminal boxes shall to be provided at regular intervals.
Adequate number of earth strips with proper sized holes shall be provided for extending earthing/looping earth connections a
The Contractor has to provide heavy duty Cover of size 450 x 450 x 8 mm thick to the Earthing Chamber.
The cover is to be sand blasted and then Powder coated using Matt Jet Black Colour. The Cover is to be fabricated using 8 mm

Earthing pits with 600 x 600 x 6mm Chemical Earthing (Gel Type) upto 10 feet deep with all
accesoreis to maintain earth resistance below 2 ohm guranteed.
6 sqmm braided copper tape for gride earthing
6 sqmm green cable
25 x 3 copper Strip for Earthing of panel
50 x 6 GI Strip for Earthing of panel
1c x 150 sqmm cu flexible (Green Colour)
Dedicated Earthing Box with 50mm x 10mm x 200mmLenght
Tinned copper strip with 6mm holes
150x150x3mm Danger Notice Board & 415 Enameled Danger Board
Shock Treatment chart with Frame In Local & English Language
First Aid Medical Box
1000mm wide 20mm thick Rubber Matting suitable for 1100 Grade

Total Part - VII


GRAND TOTAL

VAT @ 14.5%
Service Tax @ 10.3%
Total After Taxes
Grand total with taxes

Installation works
Rate
Qty.

Unit

Supply

Amount
Installation

Supply

Installation

Make of Material

MS sheet and shall comply with IS standards.

Set

599,180

29,960

1,198,360

59,920

Set

188,415

8,200

376,830

16,400

Set

266,260

11,500

532,520

23,000

Set

359,995

15,600

719,990

31,200

Set

164,180

7,000

328,360

14,000

Set

137,850

6,000

551,400

24,000

Nos

8,450

1,245

16,900

2,490

Nos

5,210

1,245

10,420

2,490

Nos

2,875

800

5,750

1,600

Nos

89,675

2,400

538,050

14,400

Nos

80,440

1,800

402,200

9,000

4,680,780

198,500

corporation of cable supports at a later date.


laid in trenches or trays.(Not to consider Trays and Trenches rates, it will be paid Seperatly)

te Slab)
r documents is the sole responsibility of the Contractor.
100

Mtr

21,535

1,800

2,153,500

Mtr

1,180

148

720

Mtr

1,512

92

1,088,640

66,240

1300

Mtr

1,215

82

1,579,500

106,600

180,000

360

Mtr

8,225

122

2,961,000

43,920

318

Mtr

1,211

60

385,098

19,080

405

Mtr

467

43

189,135

17,415

1020

Mtr

196

30

199,920

30,600

120

Mtr

309

40

37,080

4,800

625

810

64

Nos

110

215

40,000

13,760

80

Nos

83

175

8,800

14,000

16

Nos

1,045

740

1,328

11,840

36

Nos

243

270

37,620

9,720

38

Nos

87

190

3,306

7,220

192

Mtr

30

100

5,760

19,200

Mtr

82

135

656

1,080

8,691,343

545,475
-

68,700

15,000

68,700

15,000

376,800
254,400

64,800
38,880

60

Nos

1,145

250

480
240

Mtr
Mtr

785
1,060

135
162

480
240

Mtr
Mtr

322
775

95
175

154,560
186,000

45,600
42,000

971,760

191,280

en below :mum
thickness
and shall work.
comply
with
IS 2509
of 1973
amendments
there
FIA approval.
shall1.6mm
be suitable
for concealed
The
boxes
should
be oforElectro
Plated as
per of
theand
Manufactures
standard
wire for earth continuity having Green colour in 660/1100 volts grade.

drawings,and
asthe
perpoint
final and
directions
of PMC.
via
switch or to
including
providing circuit wiring, in minimum 25 mm dia MS Conduit

42

Nos

1,142

300

47,964

12,600

84

Nos.

856

215

71,904

18,060

35

Nos

1,404

300

49,140

10,500

70

Nos

1,053

215

73,710

15,050

84

nos

142

95

11,928

7,980

65

nos

345

95

22,425

6,175

nos

586

150

nos

2,775

200

hat may be required to make the fixture complete in all respects such as :-

ype bulbs

13,875
290,946

1,000
71,365

nos.

8,526

350

34,104

1,400

250

nos.

21,144

450

5,286,000

112,500

18

nos.

2,865

150

51,570

2,700

nos.

5,455

250

32,730

1,500

5,404,404

118,100

earth plate/earth pipe as called for in the item.


the two earth station shall be 3 meters and that from the building is 2500 mm.

ng/looping earth connections at various floors shall be provided and executed as per the requirement.
Chamber.
r is to be fabricated using 8 mm thick Chequered Plate.

nos

2000

mtr

120

35

240,000

70,000

750

mtr

56

30

42,000

22,500

600

mtr

530

60

318,000

36,000

400

mtr

207

95

82,800

38,000

400

mtr

1,512

92

604,800

36,800

20

nos

1,902

350

38,040

7,000

nos

115

100

460

400

nos

427

100

1,708

400

nos

996

90

3,984

360

50

mtr

1,068

70

53,400

3,500

1,385,192

214,960

21,493,125

1,354,680

3,116,503
139,532
24,609,628

1,494,212

Total Amount
Basic

1,258,280

393,230

555,520

751,190

342,360

575,400

19,390

12,910

7,350

552,450

411,200

4,879,280

2,333,500

1,154,880
1,686,100

3,004,920
404,178
206,550
230,520
41,880

53,760
22,800
13,168
47,340
10,526
24,960
1,736
9,236,818

83,700
83,700

441,600
293,280

200,160
228,000
1,163,040

60,564

89,964
59,640

88,760
19,908

28,600

14,875
362,311

35,504
5,398,500
54,270
34,230

5,522,504

310,000
64,500
354,000
120,800
641,600
45,040

860
2,108
4,344
56,900

Office Area
Server Room,Office Area
Reception Area,FM200 Cyl, POA Room

430.1
4629.596
1527.767

1,600,152
22,847,805

26,103,840

2820.168
7449.764
225.7504

CIVIL BOQ

S.No

Description

False flooring (Server room, POA Room, ANG room)

Qty

Unit

6755

Sq.ft

945

Sq.ft

1750

Sq.ft

17500

Sq.ft

17500

Sq.ft

11

Nos.

Nos.

Providing and fixing approved make and quality Calcium sulfate raised
flooring of 600x800mm tiles on 750mm adjustable height Galvanized iron (GI)
pedestals and GI stingers. The tiles should have antistatic laminates with UDL
Loading 1700kg/sqmtr

False ceiling (in OMCR Room, Lobby, Passage) (POA & ANG room
removed)
Providing and fixing modular ceiling provided mineral fibre board of
600mmx600mmx15mm in true horizontal level using a 15mm T section to be
laid on armstrong or approved equivalent grid system.

Aerocon Partition for First Floor Internal Partitions 75mm thick, 2 Hrs
fire rated..
Providing and applying FIRE Rated Paint paint of approved make and shade
to give an even shade over a primer coat and 2 finishing coats of plastic
emulsion. (fire rated Paint of makes - 3M, Cromet)

Providing and laying POP punning over cement plaster in perfect line and
level with thickness of 10 12mm including making good chases, grooves,
edges banding.
Supplying and fixing fire rated of 2 hours fire rating steel doors size 1200 x
2400mm size, double leaf, fire rated vision panel of 230 x 230mm, SS Ball
bearing butt hinges, mortise sash lock, SS lever with internal thumb turn etc
(shakti met, radiant, promate)

Supplying and fixing fire rated of 2 hours fire rating steel doors size 1000 x
2400mm size, single leaf, fire rated vision panel of 230 x 230mm, SS Ball
bearing butt hinges, mortise sash lock, SS lever with internal thumb turn etc.
(shakti met, radiant, promate)
7

Providing and fixing powder coated Aluminium doors using


100x38.1mmx2mm section for door frame and 100mm top and bottom section
using 12mm clear toughened glass with all necessary hardware, heavy duty
floor spring, 10inch long SS handle complete. Door size 1200 x 2400mm
double leaf

Nos.

Nos.

13510

Sq.ft

1300

Sq.ft

4000

Sq.ft

24

Sq.ft

12

Sq.ft

250

Sq.ft

8
Providing and fixing powder coated Aluminium doors using
100x38.1mmx2mm section for door frame and 100mm top and bottom section
using 12mm clear toughened glass with all necessary hardware, heavy duty
floor spring, 10inch long SS handle complete. Door size 1000 x 2400mm
single leaf,
9

10

Providing and fixing 19mm thick Armaflex floor insulation below the false
flooring, joints should be finished properly as per manufacturers
specifications. The rate shall be inclusive of cleaning the surface to make it
free from dust.
Providing and laying approved make and quality vitrified tile flooring polished
tiles 600x600mm size flooring to match floor pattern using chemical
adhesives and laid to corrected level of +/-6mm and joints pointed with
approved quality jointing compound including curing.

11

12

Providing and laying KOTTAH tile flooring of tile size 2-'0" x 2'-0", of approved
quality, approved colour shade as per approved pattern using chemical tile
adhesive (IF REQUIRED) laid to proper line and level and joints pointed with
tile jointing compound including curing, mirror polishing by three different
cutting stones nos as directed, finished and final cleaning etc. The
measurements shall be based on actual laid area of floor & skirting and no
extra payment shall be paid towards wastage. The rates shall include cost of
laying protective PVC sheets & POP which shall keep the floor covered at all
times till handing over of the site etc. complete.

2 hrs Fire Rated Glass with its fixing, all accessories etc in ANG room & POA
Room (Size of View Panel - Height 900mm X Width 1200mm)
13

14

Auto Glow Signages showing EXIT, MESSAGES, YOU ARE HERE Signages,
ROOM Names etc.

15

Aluminium Caging for FM200 Cylinders on first Floor

16

Ramp

Sq.ft

17

Step

Sq.ft

18

Provision of opening in wall for loading bay ( for material movement)


(NOT REQUIRED)

19

Brick works 230mm thick with plaster (For Partions of Ground floor)
P/Fixing Workstations with 3" thk partitions with 1" thk table top finished with
laminate also includes Metal keyboards tray CPU trolley and 1 no 18" x 18'
drawer box with 3 nos drawers complete with all hardwares finished in
laminate.(Table Size 4'-0" x 2'-0") (FIRE RETARDANT COATING TO BE
APPLIED on Furniture)

Lot

3430

Sq.ft

11

Sq.ft

20
21

Executive Chairs

12

Sq.ft

22

Reception table

Sq.ft

23

Security and safety of the material on Site

lot

24

House Keeping during entire execution

lot

25

Temporary Power during construction phase

lot

TOTAL Without Taxes

TOTAL With Taxes