Technical Datasheet

NanoGrout GP
GENERAL PURPOSE NON-SHRINK CEMENTITIOUS GROUT
DESCRIPTION

NanoGrout GP is cement based non-metallic, non-shrink free flow grout that


maintains a fluid consistency for a long time. NanoGrout GP was designed
for use in local conditions, with increased extended working times.

STANDARDS

BS EN 480-2 :96, ASTM C109-80, BS EN 196-1 :95, ASTM C940:89


ASTM C827-82, BS 1881:Part 107 & Part 124 :83, BS 6319 : Part 7 : 85

USES & ADVANTAGES

NanoGrout GP is a general-purpose grout designed for use in all non-critical


applications.
Ready to use, only requires addition of water.
Flowable and self levelling.
Able to fill intricate voids.
Use for concrete repair work.
Chloride free.
High strength.
Good dimensional stability.
No bleeding or segregation.
Controlled expansion.
Compensates for shrinkage in both plastic and hardened state.

TYPICAL PROPERTIES @ 25C

Appearance
Wet Density
Grouting Thickness
Yield
Water Addition
Bond Strength to Concrete
Expansion

: Grey powder
: Approx. 2.20 kg/litre
: Minimum gap width : 5 mm, Maximum : 100 mm.
: 13 Ltrs / bag
: 16% +/- 1% by weight
: 2 N/mm2 at 7 days
3 N/mm2 at 28 days
: 1% - 3% in plastic state.

APPROXIMATE FLOW AT 25OC

Water
Content
(%)
16

Flowability
(BS Cone)

Setting time
(hours-minutes)
Initial

18 - 22 cm

4.00

Bleeding

Final
4.30

Nil

Approx. Flow distance in cm.


Gap Depth
Grout Water
Content

Average Compressive
Strengths (N/mm )
1 day

3days

7days 28 days

25

40

55

Head Height

65

Head Height

mm.

10 cm.

25 cm.

15% by weight
of Grout

10
20
30
40

40 cm.
100 cm.
160 cm.
240 cm.

140 cm.
270 cm.
>310 cm.
>310 cm.

17% by weight
of Grout

10
20
30
40

100 cm.
200 cm.
>300 cm.
>300 cm.

270 cm.
>320 cm.
>320 cm.
>320 cm.

Flow distance will be affected by surface conditions, temperature, height of head and mixing time.

CC/NG02/Ver2/08/07

Construction Chemicals

1/4

SURFACE PREPARATION

Surfaces should be clean, sound and free from oil, grease, laitance and loose
particles. Metal surfaces should also be clean & free from rust, oil & grease.

MIXING

NanoGrout GP should be mixed using a suitable mixer. For flowable consistency


use a slow speed <600 R.P.M. hand drill and paddle or specialised grout mix
pumps. Powder should be added to the pregauged clean water 15% - 17%.
Mix untill uniform flowable consistency is acheived.

APPLICATION

Ensure that the surface is correctly prepared. Saturate with water at least 3 - 4
hours prior to pouring the grout. No free water should be left standing. During
application ensure air entrained into the grout is able to escape through relief
holes. Maintain continuous head when base-plate grouting. Grout flow should
not be interrupted. Formwork should be leak proof. Ensure there is no water
standing in bolt holes. If possible, grout anchor bolts first then the mortar bed
in a second operation. The distance between anchor bolt and substrate should
be at least 3 x max. diameter of mortar aggregates approx. 10 mm. A cable or
chain may be used to make sure that all cavities are filled.

Typical hopper set up for Grouting with NanoGrout GP

20 mm thick
plywood
50 x 75 mm timber
bolted to substrate

Typical hopper set up for grouting with NanoGrout GP

>15 cm

Up to 25 cm

> 50 cm

NOTE

Use NanoGrout GP with minimum gaps of 5 mm and maximum depths of 100


mm. Temperature will affect setting time and strength gain. Normal curing
practice should be maintained. For detailed application methodology, refer
Method Statement.

FORM WORK

The formwork should be watertight. Therefore a joint sealant should be used


to close all points where forms meet and also around the bottom and top of
formwork.

CC/NG02/Ver2/08/07

Construction Chemicals

2/4

PRE-SOAKING

The prepared areas should be flooded with water for 3-4 hours prior to the
placement of NanoGrout GP. Immediately before the grout is placed all free
water should be released from the area to be grouted. There should be NO
standing water present when the grout is placed.

CURING

To prevent rapid surface drying and crazing, grout should be cured with wet
burlap or moist gunny bag or use a suitable curing compound from JetCure
Range.

YIELD

13 Ltr/Bag.

GENERAL INFORMATION

Shelf Life

12 months from date of production, if stored properly in


original unopened packaging in dry conditions and away
from sunlight and scorching heat.

Packaging

25 kg.

Cleaning

Clean all equipments and tools with water

HEALTH & SAFETY

TECHNICAL SERVICE

Conmix Ltd.
P.O. Box 5936 Sharjah,
United Arab Emirates
Tel: +971 (06) 5314155
Fax: +971 (06) 5314332
www.conmix.com
CC/NG02/Ver2/08/07

PPEs

Gloves,goggles & dust mask must be worn

Precautions

It is alkaline in nature, contact with skin, eyes, etc


must be avoided, if not may cause irritation

Hazardous

It is regarded as Non - Hazardous for transportation

Disposal

Do not re-use bags. To be disposed off as per local


rules and regulations

Detailed Information

Refer MSDS for detailed information.

Conmix Technical Services are available on request for on site support to


assist the correct use of its products.

Sales Office
Tel: +971 (06) 5682422
Fax: +971 (06) 5681442
Email: conmix@conmix.com

Construction Chemicals

It is the customers responsibility to satisfy themselves by checking with the company that the information is still current at the time of use. The customer must be satisfied that the product is suitable
for the use intended. All products comply with the properties shown on current data sheets. Conmix however do not warrant or guarantee the installation of the products as it does not have any control
over installation or end use of the product. All information and in particular the recommendations relating to application and end use are given in good faith. The products are guaranteed against any
defect and are manufactured and sold subject to Conmix standard terms and conditions of sale.

3/4

Conmix Ltd.
P.O. Box 5936 Sharjah,
United Arab Emirates
Tel: +971 (06) 5314155
Fax: +971 (06) 5314332
www.conmix.com
CC/NG02/Ver2/08/07

Sales Office
Tel: +971 (06) 5682422
Fax: +971 (06) 5681442
Email: conmix@conmix.com

Construction Chemicals

It is the customers responsibility to satisfy themselves by checking with the company that the information is still current at the time of use. The customer must be satisfied that the product is suitable
for the use intended. All products comply with the properties shown on current data sheets. Conmix however do not warrant or guarantee the installation of the products as it does not have any control
over installation or end use of the product. All information and in particular the recommendations relating to application and end use are given in good faith. The products are guaranteed against any
defect and are manufactured and sold subject to Conmix standard terms and conditions of sale.

4/4