You are on page 1of 5

Prof.

and Head of the Department


Department of Electronics and Instrumentation Engineering
Annamalai University
Annamalainagar 608 002.

DATE : 22.07.2013
REF: GRA/BLR/ANM/13-14/051

Dear Sir
Sub : Quotation for Rehabilitative Lab Equipments.

We are extremely thankful to you for the above enquiry for your department. In continuation to the same we
are herewith enclosing our quotation along with Terms and condition and product brochure for your kind
perusal.
We request you to kindly go through the proposal and should you desire additional information / clarification
feel free to contact us.
We once again thank you for the enquiry and look forward to hear from you.
Thanking you
Yours Truly
For Graphic Devices

K.Srikanth
Regional Director - South

QUOTATION - REHABILITATIVE LAB EQUIPMENTS

Prof. and Head of the Department


Department of Electronics and Instrumentation Engineering
Annamalai University
Annamalainagar 608 002.
Sr no.
1

DATE : 22.07.2013
REF: GRA/BLR/ANM/13-14/051

Description
Rehabilitative Lab Equipment Setup
Comprising of :
a)LEGSYS Wearable sensor for Gait analysis
b)BALANSENS Balance and Mobility analysis
c) Tread Mill
d) BALANCE / Wobble Board
e) BERA System
a)LEGSys is easily portable and can be set up and utilized
anywhere. Conduct gait tests at your office, in patients homes, or
anywhere in between
Wireless wearable system that is portable and easy to use
Quickly analyze gait without the restraints of a gait
laboratory, such as limited walking space
Proprietary technology validated using state-of-the-art
camera-based motion capture
Automatically generated reports demonstrate patient
progress toward measurable goals
Sensors
Sensor Size: 7.3 cm x 4.0 cm x 1.8 cm
Weight: 30g (1.06 oz) g
Sample Frequency: 50 Hz
Battery Life: 4 hours
Memory Capacity: 256 Mb (> 4 hours of data)
Data Transmission: Bluetooth
Software measures
Basic Parameters
Stride Length, Stride/Step Duration, Speed, Cadence
Gait Cycle Timing
Stance Percent, Swing Percent, Double Support Percent
Stride-To-Stride Variability
Speed, Stride Length, Stride Duration

Qty

Price in
Rupees(INR)

01

8,60,000-00

b)BalanSens uses two motion sensors and advanced algorithms


based on human body mechanics.
Run balance tests on the sidelines, in the clinic virtually
anywhere
Wireless wearable system that is portable and easy to use
Quickly analyze balance without the need for force plates
Patient history allows you to assess return-to-baseline
following injury
Instant charting and analysis.
Healthy normative data for comparison.
Customizable report contents
Sensors

Sensor Size: 7.3 cm x 4.0 cm x 1.8 cm


Weight: 30g (1.06 oz) g
Sample Frequency: 50 Hz
Battery Life: 4 hours
Memory Capacity: 256 Mb (> 4 hours of data)
Data Transmission: Bluetooth

Provide over 17 measurements that include :


Centre of Mass (COM) motion
Anterior-Posterior motion
Medial-lateral motion
Ankle and hip angles
Sway velocity, Sway area
Reciprocal Compensatory Index (RCI)
c) Tread Mill
d) BALANCE / Wobble Board
e) BERA System
I - BERA Amplifier
Operating Voltage
Out Put Pin Connection Details
CMRR
Gain
Output
Enclosure
Input
Sensor Input Connector Details
Output

: 8 Volts DC
: BNC connector
: 80 dB
: 1000
: 1 V peak to peak per mV of input
:ABS
:3 Electrode system
:Five Pin Female Connector
:Compatible with DSO (with
Average mode display)

II - BERA Audio Stimulator


Operating Voltage
Out Put Pin Connection Details
Gain
Output
Enclosure
Click Repetition Rate
Synch Output

:12 Volts DC
:Phono Socket
:Adjustable
:120 dB
:ABS
:0 Hz to 10 Hz
:50 milli sec pulse per click

III - Power Supply


Charger input
Battery
Fuse
Enclosure
Total in Rs.

For Graphic Devices

K.Srikanth
Regional Director

:230V AC mains
:12V DC rechargeable (1.5 AH)
:Fuse 500mA
:ABS
8,60,000-00

TERMS & CONDITIONS

VALIDITY OF THE OFFER

90 Days from the date of Quotation

ORDER

Order has to be in the name

PAYMENT TERMS

100% advance along with Purchase Order

TAXES

Price is inclusive of all taxes

DELIVERY PERIOD

4 6 WEEKS

INSTALLATION

Free of cost

WARRANTY

12 months from date of installation or 13


months from the date of shipment, whichever
is earlier, subject to warranty conditions

For Graphic Devices

K.Srikanth
Regional Director South

You might also like