SUPPORTED BY DANA CORPORATION

WARNER ELECTRIC

The Warner Electric Motors and Controls Division of Dana Corporation is a global leader in the engineering and manufacturing of motor and control products for industrial applications. All Warner Electric
products and services are backed by highly specialized engineers and service people who can help solve
your production challenges. Warner Electrics capabilities and products have improved operations for
hundreds of companies around the world.
Warner Electric stepper motors and controls, servo motors and controls, voltage conditioning products,
engineered systems, and AC/DC drives are available worldwide through an extensive authorized distributor network. These distributors provide convenient service by offering technical support, replacement
parts, and literature, as well as an extensive inventory of off-the-shelf models for the fastest possible
delivery and service. Call your nearest distributor for ordering and application information.

Quadraline 7000
DC Drives

IN U.S.A. AND CANADA


WARNER ELECTRIC MOTORS AND CONTROLS DIVISION

Sales: 734-669-4700

Customer Service: 800-787-3532

Product Application: 800-787-3532

Product Literature Request: 800-787-3532

Fax: 800-766-6366 or 860-589-2136

Web Site: www.warnernet.com

WARNER ELECTRIC MOTORS AND CONTROLS DIVISION


Division Office
640 Avis Drive, Suite 200
Ann Arbor, MI 48108

C3003

Quadraline 7000 Cover

Bristol Plant
383 Middle Street
Bristol, CT 06010

Systems Center
13500-J South Point Blvd.
Charlotte, NC 28273

SERVO CONTROLS

International - Europe
Lausanne, Switzerland
La Pierreire
CH-1029 Villars-Ste-Croix,
Switzerland

1999 Warner Electric Division


Printed in U.S.A.

9/99

3/25/05, 1.08

STEPPER CONTROLS

VOLTAGE CONDITIONING

ENGINEERED SYSTEMS

AC/DC DRIVES

ADDITIONAL WARNER ELECTRIC DC DRIVES & CONTROLS


Quadraline 7000

Recommended
Spare Parts

Recommended Spare Parts

BRONCO II and Washdown Series DC Drives

SE2000 DC Drives

Designed for tough rugged applications, BRONCO II DC


Drives feature speed regulation 0.5 1%, dual voltage
input (115/230 VAC), output 90 or 180 VDC, to 2 HP,
circuit protection, torque control, local or remote operator
control, open chassis, field programmable jumpers,
control relay with 3-wire start/stop circuit, jog at
potentiometer speed, cast aluminium enclosure NEMA
4, NEMA 12, and NEMA 4X. Maximum and minimum
speed adjustments.

This non-regenerative DC drive is designed to control


shunt wound or permanent magnetic field DC motors
from to 5 HP. It offers isolated 4-20mA or 0-10 VDC
control signal, tachometer generator feedback, circuit
protection, diagnostic capabilities, control relay, torque
and slope control, and overcurrent protection. Jumper
selectable to program drives for specified motor or
application. Horsepower range 115 VAC to 230 VAC.
Open chassis available and UL listed.

Warner Electric
Part Number
Q7005

Description

Q7002

Q7006

Control Board Assembly*

SPC3593300

SPC3593300

SPC3593300

Line Fuse (F1, F2)

PFU101701
226636-001
(Buss JJN30A)

PFU101700
226636-000
(Buss JJN60A)

PFU101000
104364-022
(MDA15A)

Control Fuse (F3)

PFU100400
(AGC.25A)

PFU100400
(AGC.25A)

PFU100400
(AGC.25A)

SCR Module

SPATY401800

SPATY401700

Field Bridge

226122-000 PDI500500

PDI500500

MOV

202956-014 PSU200200

PSU200200

Power Board Assembly

SPC3601900

Zero Position Dancer


Control Board Assembly

Q799905

Q799905

Q799905

External Signal Option


Control Board Assembly

Q799901

Q799901

Q799901

Fault Module Option


Control Board Assembly
Independent Accel/Decel Option
Option Control Board Assembly
AC/Pulse Tach Feedback
Control Board Assembly

Q799902

Q799902

Q799902

Q799903

Q799903

Q799903

Q799904

Q799904

Q799904

* When replacing the Control Board Assembly, it is essential that all of


the set-up jumpers and adjustment potentiometers on the new board
are identical to those on the board being replaced. It may be
necessary to re-adjust the potentiometers on the new board for correct
operation. See Section 3.0 of this Manual.

Service

M4000 Digital 3-Phase DC Drives

DS9000 Digital Drive Speed Controller

The M4000 Series Digital 3-Phase DC Drive is a


programmable, microprocessor based variable speed DC
drive. It allows keypad control of each parameter. Digital
readout provides on-line monitoring of drive operation.
Ideal for many drive applications including wire and
cable, packaging/converting, machinery and material
handling. Improved circuit board technology has added
standard features, including serial communications and a
field-weakening controller for constant power and
extended speed range applications.

The DS9000 Digital Speed Controller features long term


speed accuracy, control and stability. It offers 16-bit
microprocessor based, AC or DC drive control, .01%
accuracy, digital master or follower, analog or digital
input, and two selectable sets of programmable parameters. Front panel controls include a 4-digit LED readout,
keypad controls and four LED status indicators.

Service

It is intended that the


Quadraline 7000 should be
serviced by replacing major
sub-assemblies. The Replacement Parts List lists all of the
sub-assemblies required to
service Quadraline 7000
drives. It is recommended that
users keep these parts readily
available to support the drives
critical applications.
For additional assistance
or the name of your
closest authorized service
center, contact Warner
Electric Motors and Controls
customer service at (800)
787-3532.

Quadraline 7000

*Contact Warner Electric for information on our complete line of AC Drives

Quadraline 7000 Cover

21

3/25/05, 1.09

Quadraline 7000

Connection
Diagrams

Quadraline 7000

Contents

Shunt Field Connections for DC Motors


L1
DC MOTOR
CONTROLLER L2

L1
DC MOTOR
CONTROLLER L2

Line input
115 VAC

A1

DC motor
armature
90 VDC

A1
A2
F1

A2

DC motor
armature
90 VDC

Contents

DC motor
shunt field
50 VDC

Features and Benefits . . . . . . . 2

F1

DC motor
shunt field
100 VDC

F2

Line input
115 VAC

F2

Applications . . . . . . . . . . . . . . . 4
Connections for a DC motor with a
90 VDC armature and 100 VDC
shunt field.
L1
DC MOTOR
CONTROLLER L2

Connections for a DC motor with a


90 VDC armature and 50 VDC
shunt field.
L1
DC MOTOR
CONTROLLER L2

Line input
230 VAC

A1
A2
F1
F2

DC motor
armature
180 VDC

A1

DC motor
shunt field
200 VDC

F1

Adjustment
Locations

F2

Speed Arm

J1
Tach
Range

Zero Position
Dancer Control . . . . . . . . . . . . 8

DC motor
armature
180 VDC

Options
Installation . . . . . . . . . . . . . . 9
Bipolar Isolation . . . . . . . . . 10
Fault Module . . . . . . . . . . . 11
Independent Acceleration
Deceleration . . . . . . . . . . . 12
A/C Pulse Tach
Feedback . . . . . . . . . . . . . . 13

DC motor
shunt field
100 VDC

Remote Operator
Stations . . . . . . . . . . . . . . . . . 14

7 8 8 9 10

R1
7V
50V

Selection Information . . . . . . . 7

Connections for a DC motor with a


180 VDC armature and 100 VDC
shunt field.

1 2 3 4 5 6

TB1

How to Order . . . . . . . . . . . . . . 6

Line input
230 VAC

A2

Connections for a DC motor with a


180 VDC armature and 200 VDC
shunt field.

Specifications . . . . . . . . . . . . . 5

R2

R3

Accel

R4

R5

R6

R9

R8

Bias
Torque Tach Accel (Factory
J3
set)
J2 SW1

R7

A=.3-3 sec
B=3-30 sec

J4

TB1
60 HZ
50 HZ

J5

Accel
Range

p 13
7 pt helv; .5 line

R1Max speed
R2IR comp
R3Fwd accel
R4Rev accel
R5Fwd I limit
R6Rev I limit
R7Response
R9Zero Speed

Isolation Transformers . . . . . 14
Standard DC Motors . . . . . . . 15
Dimensions . . . . . . . . . . . . . . 18
Connection Diagrams . . . . . . 19
Adjustment Locations . . . . . . 20

R69
A

Recommended Spare
Parts . . . . . . . . . . . . . . . . . . . 21

R76A
Offset
(Factory set)

Service . . . . . . . . . . . . . . . . . 21

R103

D
B

P4

C
A

J6

Current
Range

Line Voltage Select

P3

115V 230V

J9

230V 115V

P2

J10
90V

P1

Quadraline 7000

180V

J11

Quadraline 7000

20

Quad7 spreads

3/25/05, 1.16

High-response drive
Wide band width allows unit to
replace expensive servo drives in
some applications.
Regenerative braking
Motor acts as a generator and
provides braking torque.
The braking energy is returned to
the AC power line, not dissipated
as heat.
Electronic reversing
Allows rapid and continuous
cycling without any moving parts
in the control.
No mechanical contactors
required.

L1

L2

A1

A2

Rev. ()

F1

F2

Stop

F2
TB2

P2

P1

A2

1
GND

W
CCW

TB1

2
7V

10

11

Arm

J1

SWI
50V

Tach

CONTROL PC BD.

115V

HEATSINK ASSY.

J9 J10
90V

180V
J11

Notes:
1. Ground control per local and
national codes.
2. Customer supplied line fuses;
size for protection of AC line
wiring and transformer per
local and national codes.
3. Programming jumpers J9,
J10, and J11 on control board
must be positioned for 115 or
230 VAC line.
4. Polarity shown is for positive
speed reference voltage at
TB14 (fwd direction).
5. For PM motors, no
connection is necessary to F1
and F2.
6. DC tachometer (7VDC/1000
RPM or 50 VDC/1000 RPM)
is optional; when used, select
tach feedback mode (SW1)
and tach voltage level (J1).

Protection
Input AC line fuses protect
control from line or load faults.
MOVs protect unit from voltage
transients on AC power line.
Optional features include:
NEMA 4/12 enclosure
Fault module
Bi-polar isolated input module
Independent Individual control
of forward accel and decel and
reverse accel and decel rates
AC pulse tach feedback

Quadraline 7000

7. Speed adjust potentiometer:


2K to 10K.
8. Selector switch determines
direction of motor rotation.
For Bi-directional operation
without switch. Connect CCW
potentiometer lead to TB16.
9. TB17 and 8 must be
connected together to enable
control; jumper is factory
installed. Open this circuit to
disable control.
10. Start (n.o.) and stop (n.c.)
momentary pushbuttons are
used for conventional 3-wire
control. If 2-wire control is
required, connect maintained
switch or contact between
TB19 and TB111.
11. If motor thermostat (P1, P2) is
available, connect in series
with stop pushbutton as
shown.

Quadraline 7000

19

Quad7 spreads

+ F1

+ A1

11
10

CW

Start

115/230 VAC

230V

Selectable features
Selected by programming
jumpers to program drives for
specific motor or application:
AC Supply selects 115V or
230 VAC
Current Scaling selects current
range to match control to a
particular motor HP Rating
Speed Feedback selects
armature voltage feedback or
tachgenerator feedback for
improved speed holding
Acceleration/Deceleration Time
selects range for adjustment
control up to 30 secs
Torque or Speed Control selects
mode of either motor speed or
motor torque controlled by
operators potentiometer
AC Supply Frequency allows
drive to be operated on 50 Hz
or 60 Hz supply

Adjustments
Customer adjustments to match
control to application:
Maximum speed limits speed
available at operators control
Forward Acceleration sets time
to reach full speed in forward
direction is also reverse
deceleration time
Reverse Acceleration sets time
to reach full speed in reverse
directionis also forward
deceleration time
IR Compensation improves
motor speed regulation in
armature feedback mode
Forward Current Limit sets
maximum current available in
forward direction to limit motor
overload
Reverse Current Limit sets
maximum current available in
reverse direction to limit motor
overload
Response sets response
characteristic of control for
higher performance
applications

Connection
Diagrams

Fwd (+)

Full wave four quadrant


operation
Provides smooth motoring or
braking torque in either direction
of rotation.

UL Listed Ratings
Horsepower range
115 VAC
1/41 HP
230 VAC
1/25 HP
150% full load current available
for 1 minute.

230V

Designed for either permanent


magnet or wound field motors
Field supply is standard.
Allows use of a wide range of
motors.

115V

The Quadraline 7000 series is a


full wave, regenerative DC drive
designed to operate shunt wound
or permanent magnet DC motors
from 1/4 HP to 5 HP.
Regenerative drives are the ideal
answer for:
Maintaining motor speed
when an overhauling load
attempts to increase the
motor speed
Providing continuous
braking torque with no power
dissipation
Repeatable, controllable
braking to rest
Rapid, repetitive reversal of
motor rotation
The Quadraline 7000 models are
packed with features, designed
and manufactured to the highest
quality standards and available
from your local Warner Electric
Motors and Controls distributor at
an economical price.

Speed adj.

Features and
Benefits

Quadraline 7000

DC tach
100 VDC max.

Quadraline 7000

3/25/05, 1.16

Quadraline 7000

Dimensions

Quadraline 7000

Features and
Benefits

Chassis

Q7006 Series

Q7002/7005 Series
.75

.218 Dia. (4)

.187 x .375 slot (2)

11.75
10.25

9.625
9.000
.187 Dia. (2)

7.375
3.375

9.125
9.50

.375
5.50

8.00

Dimensions are listed in inches.

Feature Packed
Enclosed

Q7002/7005 Series

Full wave 4-quadrant operation


Provides smooth motoring or
braking torque in either direction
of rotation.

.218 Dia. (4)

10.25

7.562
8.375

7 Selectable performance
features

13.00

8.750
9.50

115V/230V AC Input
Accel/Decel Range
Internal/External Jog Reference
HP Select
Overcurrent Trip Select
Timed/Instantaneous/Disable
Motor Field Type
PM or Shunt Wound
Feedback Type
High-response drive
Wide-band width allows unit to
replace expensive servo drives in
some applications.

Electronic reversing

115/230 VAC Input

Regenerative braking
Motor acts as a generator and
produces braking torque.

Positioning accuracy
4 quadrant control provides
positioning easily adapted to
specific programming needs.

7 Control adjustments
Max. speed, forward and reverse
acceleration, IR compensation,
forward and reverse current limit,
response characteristic.
For use with shunt wound or
permanent magnet DC motors

Total control
Controlled acceleration and
deceleration. Smooth, consistent,
accurateideal for web
tensioning applications.
* Chassis or NEMA 4/12
enclosure

Complete electrical protection


1/4 to 5 HP
150% full load current available
for 1 min.

Listed

Listed for use in Canada

Dimensions are listed in inches.

Quadraline 7000

*All units except Q7006

18

Quad7 spreads

Quadraline 7000

3/25/05, 1.17

Quadraline 7000

Applications

Quadraline 7000
Material Handling

DC Motors

1/4 to 1 Horsepower 90 VDC Armature 100/50 VDC SHUNT WOUND FIELD 1750 RPM Totally Enclosed

Controlled acceleration
Controlled deceleration
Bi-directional
Precise positioning accuracy

HP

Motor
Type

Frame
Size

1/4
1/2
3/4
1

B
B
B
B

413D
420D
428D
535D

Enclosure

NEMA
C
Face

FC
FC
FC
FC

56C
56C
56C
56C

Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

MOD1211700
MOF1211700
MOG1211700
MOH1211700

TAC 400100
TAC 400100
TAC 400100
TAC 400700

MOD1211731
MOF1211731
MOG1211731
MOH1211731

Standard
DC Motors

Note: All motors are capable of 20:1 constant torque speed range.

Machine Tools
4 quadrant control allows
positioning easily adapted to
specific program needs

DC Motors
1/2 to 5 Horsepower 180 VDC Armature 200/100 VDC SHUNT WOUND FIELD 1750 RPM Totally Enclosed
Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

56C
56C
140TC
56C
180C
140TC
180C
180C

MOF2211700
MOG2211700
MOH2210800
MOH2211800
MOH2110100
MOI2210800
MOI2110100
MOI2211400

MOF2211731
MOG2211731
MOH2210831
MOH2211831
MOH2110131
MOI12210831
MOI2110131
MOI2211431

TAC 400100
TAC 400100
TAC 400102
TAC 400701
TAC 400203
TAC 400402
TAC 400203
TAC 400115

FC
FC
NV

140TC
180C
180C

MOJ2210800
MOJ2211400
MOJ2110100

MOJ12210831
MOJ2211431
MOJ2110131

TAC 400402
TAC 400115
TAC 400203

NV
FC
FC

180TC
140C
210C

MOK2110100
MOK2210800
MIK2211100

MOK2110131
MOK2210831
MOK2211131

TAC 400203
TAC 400402
TAC 400106

210C
256UCZ

MOL2110700
MOL2211100

MOL2110731
MOL2211131

TAC 400203
TAC 400108

HP

Motor
Type

Frame
Size

Enclosure

1/2
3/4
1

B
B
G
B
G
G
G
B

420D
428D
146ATC
535D
L182ACY
148ATC
L186ACY
636D

FC
FC
FC
FC
NV
FC
NV
FC

G
B
G

149ATC
646D
L186ACY

G
G
B

189ATC
1412ATC
7544D

G
B

CD2110ACY* NV
9143D*
FC

NEMA
C
Face

Web Processing
Accurate web or material
tensioning
Zero position dancer (P.I.D.
Gain Control)
Smooth and consistent control
in process, and during un-wind
or wind-up

1-1/2

Robotics
Economical alternative to
sophisticated Servo control in
less demanding applications
Chassis mount for easy
integration in customer control
panel

*These motors have 1-1/8" shaft diameter.


Note: All motors are capable of 20:1 constant torque speed range.

Quadraline 7000

Quadraline 7000

17

Quad7 spreads

3/25/05, 1.17

Quadraline 7000

Standard
DC Motors

Quadraline 7000
DC Motors

Specification

1/4 to 1 Horsepower 90 VDC Armature PERMANENT MAGNET FIELD 1750 RPM Totally Enclosed
NEMA
Enclosure C
Face

Q7006

Q7002

Q7005

1/81/2
1/41
115 or 230 V 10%
50/60 Hz 2 Hz
Single Phase

1/41 HP
1/22 HP
115 or 230 V 10%
50/60 Hz 2 Hz
Single Phase

Not Used
35 HP
115 or 230 V 10%
50/60 Hz 2 Hz
Single Phase

Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

Horsepower Range
115V
230V
AC Line Input Voltage
AC Line Frequencey
115 VAC Supply
Armature Voltage
Field Voltage

090 VDC
50/100 VDC

090 VDC
50/100 VDC

Not Applicable
Not Applicable

230 VAC Supply


Armature Voltage
Field voltage
Service Factor
Duty
Maximum Load Capacity
Line Protection
U.L. Listed

0180 VDC
100/200 VDC
1.0
Continuous
150% for 1 min.
Fuses
No

0180 VDC
100/200 VDC
1.0
Continuous
150% for 1 min.
Fuses
Yes

0180 VDC
100/200 VDC
1.0
Continuous
150% for 1 min.
Fuses
Yes

HP

Motor
Type

Frame
Size

1/4

G
B

56HAA
320P

NV
NV

56C
56C

MOD6110210
MOD6211200

N/A
MOD6211231

N/A
TAC 400113

1/2

G
B

56KAA
336P

FC
NV

56C
56C

MOF6210210
MOF6211200

N/A
MOF6211231

N/A
TAC 400113

3/4

G
B

56PAA
428P

FC
FC

56C
56C

MOG6210210
MOG6211100

N/A
MOG6211131

N/A
TAC 400100

G
B

56SAA
435P

FC
FC

56C
56C

MOH6210210
MOH6211100

N/A
MOH6211131

N/A
TAC 400100

Note: All motors are capable of 20:1 constant torque speed range.

Specifications

Q7006

Operating Conditions
DC Motors
1/2 to 5 Horsepower 180 VDC Armature PERMANENT MAGNET FIELD 1750 RPM Totally Enclosed
Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

56C
56C

MOF7210210
MOF7111100

N/A
MOF7111131

N/A
TAC 400113

FC
NV

56C
56C

MOG7210210
MOG7211100

N/A
MOG7211131

N/A
TAC 400110

146ATC
56SAA
435P

FC
FC
FC

140TC
56C
56C

MOH7210800
MOH7210210
MOH7211100

MOH7210831
N/A
MOH7211131

TAC 400402
N/A
TAC 400100

B
G

536P
148ATC

FC
FC

140TC
140TC

MOI7211100
MOI7210800

MOI7211131
MOI7210831

TAC 400701
TAC 400402

B
G

548P
149ATC

FC
FC

140TC
140TC

MOJ7211100
MOJ7210800

MOJ7211131
MOJ7210831

TAC 400701
TAC 400402

G
B

1412ATC
649P

FC
FC

140TC
180TC

MOK7210800
MOK7211100

MOK7210831
MOK7211131

TAC 400402
TAC 400115

681P

FC

180TC

MOL7211100

MOL7211131

TAC 400115

HP

Motor
Type

Frame
Size

Enclosure

1/2

G
B

56KAA
336P

FC
NV

3/4

G
B

56PAA
336P

G
G
B

1-1/2

NEMA
C
Face

Note: All motors are capable of 20:1 constant torque speed range.

Ambient Temperature
Chassis Model
055 C
055 C
055 C
Enclosed Model
N.A.
040 C
040 C
Relative Humidity .................................................... 595% non-condensing ......................................................
Altitude ......................................................................... to 3300 ft. (1000m) .........................................................

Performance Characteristics
Speed Range
50:1
50:1
50:1
Speed Regulation (% of motor base speed) for 95% load change
Arm. Voltage Feedback ................................... 1% to 2% (depending on motor) .............................................
Tach. Feedback ................................... 1/2 to 1% (depending on tach generator) .............................................
Acceleration (forward or reverse)
Range A ..................................................... Linear .33 seconds (to full speed) ...........................................
Range B .................................................... Linear 330 seconds (to full speed) ...........................................

Adjustments
Q7005

Current Range
(nominaladjustable to 150%)

1.0, 1.5, 2.0, 3.0


2, 3, 4, 6, 10, Amps
15, 25 Amps
5.0 Amps
Maximum Speed ................................................. 70105% of motor base speed ...............................................
IR Compensation .............................................................. Adjustable .................................................................

Options

Description

Isolated Input

Bipolar, inputoutput with selectable inputs for 0 to 10 VDC, 0 to 14 VDC,


0 to 100 VDC, 1 to 5mA or 4 to 20mA
Contact outputstrips on overcurrent, overvoltage or field loss
Forward acceleration, forward deceleration, reverse acceleration, reverse
deceleration, 4 potentiometers
Converts signals from AC tachometer or pulse generator to direction sensitive
DC voltage for improved speed regulation

Fault Module
Independent Acceleration/
Deceleration Control
AC/Pulse Tach Feedback

Quadraline 7000

Quadraline 7000

16

Quad7 spreads

Q7002

3/25/05, 1.17

Quadraline 7000

Quadraline 7000

How to Order

How to Order
In determining the components
that comprise a drive system, the
following selections must be
made for features and options.

1. DC Motor Controller

4. Isolation Transformer

Select HP and AC input voltage.


The AC input voltage will
determine motor armature and
field voltage.

Select KVA of transformer when


required by adding the total HP of
all drives to be connected to the
transformer. Then select model
number by primary input voltage
and secondary output voltage.

AC Input
Voltage

Motor Voltage
Arm/Field

115V

90V Arm
50/100V Field
180V Arm
100/200V Field

230V

Now select drive configuration,


chassis or enclosure. If enclosure, do you want a blank front
cover or operators controls?
Determine which operators are
required (i.e., run/jog, auto/
manual) and whether they will be
on a remote operators station or
on the drive enclosure. From the
list of standard option boards,
select those required for your
application.

2. DC Motor
With the motor voltage specified
by the AC input voltage selected
above, now determine permanent
magnet or shunt wound, frame
size, enclosure type (TEFC or
TENV), C face, and whether a
tachgenerator will be required.

3. Remote (ROS) Operator


Station

Selection charts for DC motors,


available from Warner Electric
Motors and Controls, are listed on
the following pages. For more
complete specifications and
dimensional information, contact
Warner Electric Motors and
Controls customer service.

5. Options/Accessories
A. Determine which options are
required for your applications.
This could include speed and/
or load meters.
B. Options may be mounted by
the factory or field installed.

Motor chart specify:


Horsepower
Motor Type (Manufacturer)
B=Baldor
G=General Electric
Frame Size
Motor Enclosure
TE=Totally Enclosed
TEFC=Fan Cooled
TENV=Non Ventilated
C Face Size
(For use with Single Phase
Controllers only)
Armature Voltage
Model Number
Motor with Tachometer
(mounted)
Motor without Tachometer
Tachometer Kit

Non-Listed Motors
Non-listed motors are available,
but specific information is
required.
1. Motor horsepower
2. RPM
3. Frame size
4. Volts, armature
5. Volts, field or PM
6. Enclosure
7. Conduit location, F1, F2 etc.
8. Thermostat
9. Accessory endshield
10. C face
11. Delivery requirements
12. Special application or
environmental considerations
and other important
information.

Standard
DC Motors

Example
A conveyer requires a 1 HP DC
motor, 1750 RPM, shunt wound
field, TEFC enclosure and a
7V/1000RPM tachometer. The
DC drive will be chassis mount,
230 VAC single phase input, to
be operated from a ROS. ROS to
include forward and reverse,
start/stop and a speed potentiometer. Isolation transformer from
a 230 VAC input is required. The
user would also like fault output
contacts to activate other
machine control.
Item

Qty

1
2
3
4
5

1
1
1
1
1

Part No.
Q70062
MOH2210831
R1002
TRS21020
(included as a
part of item 1)

If a remote operators station will


be used, select which operators
will be used, and the NEMA
rating required.

Quadraline 7000

Quadraline 7000

15

Quad7 spreads

3/25/05, 1.17

Quadraline 7000

Remote
Operator
Stations

Quadraline 7000
Quadraline 7000 Series

Remote Operator Stations (ROS)


Function

Model
Number

Start-Stop Switch (2)


Run-Jog Switch
Forward-Reverse Switch
Auto-Manswitch
Single Turn Speed Pot
Start-Stop Switch (2)
Run-Jog Switch
Auto-Man Switch
Single Turn Speed Pot
Start-Stop Switch (2)
Forward-Reverse Switch
Run-Jog Switch
Single Turn Speed Pot
Start Pushbutton (1)(3)
Stop Pushbutton
Single Turn Speed Pot

R1000

R1001

R1002

R8005

Input
Input
Line
Line
Voltage

HP

115 VAC
1 Phase

Basic On/Off

Zero Position
Dancer Control

Chassis NEMA
4/12

NEMA
Chassis
4/12 w/
Operators

NEMA
4/12

NEMA
Chassis
4/12 w/
Operators

1/81/2

Q7006

N/A

N/A

Q70061

N/A

N/A

Q70065 N/A

230 VAC
1 Phase

1/41

Q7006

N/A

N/A

Q70061

N/A

N/A

Q70065 N/A

115 VAC
1 Phase

1/41

Q7002

Q7022

Q7032

Q70021

Q70221 Q70421

Q70025 Q70225

230 VAC
1 Phase

1/22

Q7002

Q7022

Q7032

Q70021

Q70221 Q70421

Q70025 Q70225

230 VAC
1 Phase

35

Q7005

Q7025

Q7035

Q70051

Q70251 Q70451

Q70055 Q70255

Run/JogForward/Reverse
Includes power unit, control logic
and enclosure if specified with or
without operator devices.
Operator devices include: StartStop switch, Run-Jog switch,
Forward-Reverse switch, single
turn Speed Setting Potentiometer
and Power Light.

Note:
(1) NEMA 12 Enclosed with wiring to operators.
(2) NEMA 4/12 Enclosed with wiring to terminal strips.
(3) For non-reversing application only.

External Signal

External Signal
Includes power unit, control
logics, isolated signal follower
accepting 420 mA, 1 5mA, 0
10 VDC, 0 14 VDC or 0
100 VDC reference signal
inputs and enclosure if specified
with or without operator devices.
Operator devices include: StartStop switch, Run-Jog switch,
Forward-Reverse switch, AutoManual switch, single turn Speed
Setting Potentiometer, and Power
Light.

Selection
Information

NEMA
4/12

Zero Position Dancer Control


For tension applications such as
an unwind, rewind or tension
infeed with a zero position dancer
or load cell includes PID function.
This feature is used in special
applications usually involving
web-processing equipment.

Options

Isolation
Transformers

Description

Isolation Transformers
Single phase NEMA I Enclosed, Dry Type, No Taps, 60 Hz
HP

KVA

Primary
Voltage

Secondary
Voltage

Model Number

1/4

1/2

120/240

120/240

TRS21-005

1/2

120/240

120/240

TRS21-010

3/4

11/2

120/240

120/240

TRS21-015

120/240

120/240

TRS21-020

11/2

240/480

120/240

TRS42-030

240/480

120/240

TRS42-050

71/2

240/480

120/240

TRS42-075

10

240/480

120/240

TRS42-100

For dimensions and connection information, contact Warner Electric Motors and Controls customer service.

Quadraline 7000

Factory
Installed
M/N Suffix

Field
Installed
Kits M/N

Q799901

Fault
ModuleContact outputs
.
-trips on overcurrent,
overvoltage or field loss.

Q799902

Independent Accel/Decel
ControlForward accel,
forward decel, reverse accel,
reverse decel, 4 potentiometers

Q799903

AC/Pulse Tach Feedback


Converts signals from AC
tachometer or pulse generator to
direction sensitive DC voltage for
improved speed regulation

Q799904

Mounting and connecting


hardware for 2 option kits

Not
Required

Q7098-00

Pivot Point Sensor


(for use w/zero position
Dancer controlled models)

APT 2043-00

Isolated InputBipolar,
input-output with selectable
inputs for 0 to 10 VDC, 0 to 14
VDC, 0 to 100 VDC, 1 to 5mA
or 4 to 20 mA.

14

Quad7 spreads

Quadraline 7000

3/25/05, 1.17

Quadraline 7000

Zero
Position
Dancer
Control

Quadraline 7000
Connection Diagram

Winder
Dancer
Roll

Pivot
Point
Sensor
Motor

1. General Description

2. Specifications

The AC/Pulse Tach Option board


allows the use of either an AC
tachometer or a magnetic pulse
tach for speed feedback to the
Q7000. A ring tach, such as the
MTK series used with the DS
9000 Digital Front End, can be
used. The standard drive requires
a DC analog tachometer 7 VDC/
1000 RPM, or 50 VDC/1000
RPM, if a tachometer is to be
used. If an encoder is to be used,
please consult Seco Electronics
for adjustment.

Input Signal
Primarily designed for 60 pulse
per revolution pulse
tachometers. Maximum
frequency input is 3600 Hz.
Minimum frequency for full
output voltage is 1200 Hz.
Maximum voltage 100V.

Options
A/C Pulse
Tach
Feedback

Output signal
0 to 10 VDC.

Component Location
GND

L1 L2

Maximum
Speed
Adjustment

Offset
Adjustment

A1 A2 F1 F2

Q7000 Heatsink Assembly

R
4
0
7

TB1

Offset

Max Spd

AC Pulse Tach Feedback

9 10 11

TB1

Q7000 Control Board

Input
Signal
from
Pulse/
Tach

V
Out

V
In

U1

TB41

U2
1

Com
1

TB40

TB52

Gain

C2

J6

C4

6
4

R5
R10
TP
2

R4

U1

J50

230V

J51

115V

L1
TB53

Z1

J53

Quadraline 7000

The zero position dancer option


board provides dancer control for
either an unwind, rewind or infeed tension control systems. In a
dancer system, closed loop
control is accomplished because
the web completes the path
between the motor and the
dancer. With the zero position
dancer option board, (hereafter
referred to as the ZPD Board) the
dancer remains in a fairly
constant position throughout the
run.

The purpose of the ZPD board is


to stabilize the system and keep
the dancer in a fixed position,
thus maintaining tension within a
given tolerance range.
The pivot-point sensor, coupled
to the pivot point of the dancer
arm, generates a signal to the
ZPD board signifying the position
of the dancer arm and the
direction and velocity of any
dancer arm movement. The
Dancer Position potentiometer
adjusts the dancer zero point
electrically within the control.
Terminals are provided for a

T856

VR5

P40

TP40

Proportional
Gain
R24 TP
6
R23
Derivative
Gain
R33

16

Ribbon Cable to Q7000

P
VR4

5
6

I
VR6

7
8
9

Connection Diagram

ABC

remotely mounted Dancer


Position potentiometer.
The adjustments contained on
the ZPD board enable the system
to be fine tuned to the exact
parameters of the application to
provide optimum control and
stability.

2. Specifications
Dancer pot (Pivot point sensor)
1k OHM min., 20k OHM max.
M/N APT 2043-00

R40
Offset

AC Tach
60 Pulse/Rev
3600 RPM Max
T

R42
Max Spd

3
3 V
In
2
1 Com
TB40

1
TB1
7V
J1
50V
1

Max
Spd
R1

Arm
SW1
Tach

2
1
TB41

AC/PULSE TACH
FEEDBACK OPTION
P40

V Out

Notes:
1. Place jumper J1 in 7V position.
2. Select tach feedback mode. (SWI)
3. Adjust R42, max. speed to set
maximum motor speed. (R1, max.
speed on Q7000 control board
should be set fully CCW)

P4

3
Q7000 CONTROL BOARD

Quadraline 7000

13

Quad7 spreads

TB54
L52

J54
ABCD

U8

RC1

1. General Description

TP
7

U4

J52

T856

U3

TP
5
115V

U7

U2

F1

L2

Derivative
TP Gain
4
R28 TP
TP R26 9
8

TP3
TP
1

R6

U6

11

U3

T856

TP
10

4
+

Output
Signal

U5

CO

SW1

01

CG

Dancer Position
VR1

R2

OT

TP
11

P50

VR2

J4

COM +

D51 TB50

OS

R56

L52

R55

L51

R54

R50

R53

R52

R51

Open

R
4
2

3/25/05, 1.17

Quadraline 7000

Options
Independent
Acceleration
Deceleration

Quadraline 7000
1. General Description

The second, Mode B, allows two


different Accel/ Decel rates to be
selected by an outside sourced
contact closure. Like the Basic
Quadraline 7000 the Forward
Acceleration and Reverse
Deceleration rates are identical
as are the Reverse Acceleration
and Forward Deceleration rates.
The Mode B difference allows the
ability to switch through contact
change from either of two sets of
adjustments, thereby giving two
entirely different rates rather than
the single rate allowed with the
basic Quadraline 7000 controller.

The standard Q7000 Series DC


controller has a single forward
acceleration adjustment pot and
single reverse acceleration
adjustment pot. The Forward
Acceleration pot also sets the
acceleration rate in the forward
direction, and the deceleration rate
in the reverse direction, i.e. both of
these rates will be the same.
Conversely, the Reverse Acceleration pot also sets the deceleration
rate in the Forward direction,
again, both rates are the same.
Two modes of Accel/Decel control
can be programmed with this
option.

The adjustment setting for


acceleration determines the
amount of time the motor
controller will take to drive the
motor from standstill or zero
speed up to maximum speed.
The adjustment setting for
deceleration determines the time
the motor controller will take to
brake the moter from maximum
speed to zero.

The first, or Mode A, provides two


acceleration adjustment pots and
two decelation adjustment pots.
This allows for independent
adjustment of the forward acceleration rate, forward deceleration
rate, reverse acceleration rate and
reverse deceleration rate.

2. Specifications

Installation

A. Accel/Decel Time Range:


Jumper Selectable for each
pot
(J21J24)
F Range .33 seconds (zero
to full speed)
S Range 330 seconds (zero
to full speed)
B. Operating Modes:
Jumper Selectable (J20)
A Mode:
Acceleration Forward R21
Deceleration Forward R20
Acceleration Reverse R22
Deceleration Reverse R23
B Mode:
Pot operation in the B Mode
is controlled by a contact
closure or jumper on TB20.

Each version of the Q7000


control except the Q7006 has
provision for mounting up to two
option boards. Q7006 units have
room for one option board. If one
option board is fitted it will be in
postion A in Figure A. The
second option board will be fitted
in position B. Reference Figure A.

Options
Factory or
Field
Installed

Component Location
Time
Range
Select
F .33 sec.
S 330 sec.

Forward
Deceleration
Adjust

Forward
Acceleration
Adjust

Reverse
Deceleration
Adjust

Reverse
Acceleration
Adjust

Location A
Fwd
Decel

Fwd
Accel

R20

Rev
Accel
R21

CW

F
S

CW

F
S

J21

R22

CW

U1

R23
CW

F
S

J22

Operating
Mode
Selection

Rev
Decel

J23

U4

F
S
J24
A
B

U3

J20

TB20

Operating
Mode B
Control

Location B
P4
Logic Board

C7

Independent
Independent
Acceleration
Acceleration
Deceleration
Deceleration

P20
1

16

Ribbon Cable
to Q7000 Control Board

Connection Diagram

A. For field installation of one


ACCEL/DECEL
OPTION BOARD

J20

2
2
1

A
B

P20

P4
A

TB20

Operating
Mode B
Control
Switch
(Optional)

Notes:
1. Jumper J3 on Q7000 control board
must be placed in the center
position as shown for proper
operation of accel/decel option
board.
2. Reference section 2.b for
description of operation modes.

option, the correct mounting


hardware will be supplied with
the option kit.

B. For field installation of two


options, an additional
mounting kit Q709800 for
location B is required.

J3

1
A
Q7000 CONTROL BOARD

Quadraline 7000

Quadraline 7000

12

Quad7 spreads

3/25/05, 1.17

Quadraline 7000

Options
Bipolar
Isolation

Quadraline 7000
Component Location
Range
Selection
Jumper

Offset
Adjustment

Minimum
Speed
Adjustment

Min Spd Max Spd

Offset

R
4
0

Maximum
Speed
Adjustment

R
4
1

BipolarIsolation
Isolation
Bipolar

R
4
2
Trim
CW

Optional
Trim Pot

Input
Signal

0-10V 1
0-14V
0-100V
1-5MA
4-20MA

U1

CCW
V
Out

U2

Output
Signal

TB41

U3

TB40 J40
1
1

U5

1 U6

U4

The Bipolar Isolation Option


Board provides an isolated
interface between the Q7000 and
Reference control signals. The
Option Board mounts easily to
the Q7000 Control Board via
stand-offs and a ribbon cable.

The Fault Module Option Board


provides adjustable overvoltage
and overcurrent as well as field
loss protection for the Q7000
series of DC motor controllers.
The overcurrent protection can
be jumpered for either instantaneous overcurrent trip or timed
overcurrent trip. (An overload will
eventually cause an overcurrent
trip with the time to trip decreasing as the current level increases
when the timed mode is
selected.) An open collector
transistor output is provided to
indicate when an overload is
present. Four Red LEDs are on
the board, to indicate overcurrent
trip, overvoltage trip, field loss
trip, and overload.

Input Signals:
Current
15mA DC
420mA DC
Output voltage:

TP40

1. General Description

2. Specifications

W
V
In
I
In
Com

1. General Description

P40

U7

U8

Jumper
Position
010 VDC
014 VDC
0100 VDC

Connection Diagram
1

DC Current Input

Input Common

2
1

TB40

REV

BI-Polar
Isolation
Option

TB41

CW
FWD

Speed

0 to 10 VDC

Operation and Adjustment


Jumper Selection
Select input range
For voltage input, connect
input wires to the V IN and
COM (common) positions on
TB40. Jumper J40 as follows:

16

Ribbon Cable to Q7000

DC Voltage Input

Voltage
0 to 10 VDC
0 to 14 VDC
0 to 100 VDC

Trim
(Optional)
CW
W
CCW
V Out

2. Specifications
A. Adjustable Instantaneous or
Timed Overcurrent Trip.
Current trip setting 30 to
150% rated current.
B. Adjustable Overvoltage Trip.
Voltage trip setting 10 to
150% rated voltage.

Component Location
Fault Trip Level Adjustment:
Overcurrent
Overvoltage

Fault Relay
Contact

Voltage
Input
Range

Over
Voltage

0 to 10 VDC
1 to 14 VDC
0 to 100 VDC

OV

TB30
1
2
3
4
5
6
7
8
9

For current input, connect input


wires to the I IN and COM
(common) positions on TB40.
Jumper J40 as follows:
Jumper Position
15mA DC
420mA DC

U1

K30

U3

U4
1

TBI

TP33

P30

Com

TB31
1
2

J30
16

Field

PM
SH

Ribbon Cable
to Q7000

Motor Field
Input
Connect in
Series with
Motor Field

Motor Field Select:


Permanent Magnet (PM)
Shunt Wound (SH)

Overcurrent
Indication
Remote
Reset
(Optional)

TB30

Stop

Start

1
2
3
4
5
6
7
8
9

9 10 11
TB1
Q7000 CONTROL BOARD

P31

P32
FAULT
MODULE

P30

Motor
TB31 2
Field
1
F1
F2
2

F1 F2
P4

Q7000
POWER COMPONENT
ASSEMBLY

Notes:
1. Fault relay contacts are shown in
trip or power off condition.
Connect contact in series with stop
circuit as shown to activate stop
function when trip occurs. If this
connection is not made, control is
disabled when trip occurs and will
start when trip circuit is reset.
2. No connection is required for PM
motor.
3. Close contacts to reset trip circuit.
4. Overcurrent indication: Open
collector output sinks up to 250mA
if current exceeds overcurrent
level. (24 VDC max.)

Quadraline 7000

11

10

Quad7 spreads

Overcurrent
Trip Select:
A Timed
B Instantaneous

TP30

Q7000 CONTROL BOARD

Quadraline 7000

J31

U6

K30

P4

1. If optional trim pot is used,


remove jumper from TB413
and 4.
2. Mounted on the enclosure
door of External Signal
Models equipped with this
provision.

B A

+24V

Connection Diagram

Remote Reset
Quick Connect

P32

U5

AUTO

P31

SW30

R31

Fault
Relay
P40

OC

Local
Reset

U2

FL

Reset

Fault
Module

K30

Options
Fault
Module

Trip

Fault
FaultModule
Module
R30

C. Field Loss, detects loss of


field current.
D. Fault Relay, with 2 form C
contacts, that is energized
when power is applied and no
faults are present.
E. Open Collector Output
signifying an overcurrent
condition is present. Timed
overcurrent trip will occur if
the overload remains
(Overcurrent LED D30
indicates output is on.) This
circuit can handle 250mA (24
VDC max.) when the output is
pulled down to zero during an
overload.
F. Four Red LEDs
1. Overcurrent Trip
2. Overcurrent voltage
3. Field Loss Trip
4. Overcurrent Present

Fault Trip
Indication LEDs
OV Overvoltage
FL Field Loss
OC Overcurrent

Overcurrent
Indication LED

Over
OC
Current
TP31

TP32

Ensure Jumper J41 is in


postion A.

MAN

Two form C contacts are provided


from the fault relay that change
state in the event of a fault trip.
An on-board reset pushbutton or
quick connect connections are
provided for resetting the drive
after a fault occurs. When a fault
occurs, the drive is disabled,
turning off the SCR power bridge,
the motor will coast to a stop. If
the fault relay contacts are wired
into the stop circuitry, the Stop/
Start relay in the Quadraline 7000
controller will drop out.

10

3/25/05, 1.18

Quadraline 7000

Options
Bipolar
Isolation

Quadraline 7000
Component Location
Range
Selection
Jumper

Offset
Adjustment

Minimum
Speed
Adjustment

Min Spd Max Spd

Offset

R
4
0

Maximum
Speed
Adjustment

R
4
1

BipolarIsolation
Isolation
Bipolar

R
4
2
Trim
CW

Optional
Trim Pot

Input
Signal

0-10V 1
0-14V
0-100V
1-5MA
4-20MA

U1

CCW
V
Out

U2

Output
Signal

TB41

U3

TB40 J40
1
1

U5

1 U6

U4

The Bipolar Isolation Option


Board provides an isolated
interface between the Q7000 and
Reference control signals. The
Option Board mounts easily to
the Q7000 Control Board via
stand-offs and a ribbon cable.

The Fault Module Option Board


provides adjustable overvoltage
and overcurrent as well as field
loss protection for the Q7000
series of DC motor controllers.
The overcurrent protection can
be jumpered for either instantaneous overcurrent trip or timed
overcurrent trip. (An overload will
eventually cause an overcurrent
trip with the time to trip decreasing as the current level increases
when the timed mode is
selected.) An open collector
transistor output is provided to
indicate when an overload is
present. Four Red LEDs are on
the board, to indicate overcurrent
trip, overvoltage trip, field loss
trip, and overload.

Input Signals:
Current
15mA DC
420mA DC
Output voltage:

TP40

1. General Description

2. Specifications

W
V
In
I
In
Com

1. General Description

P40

U7

U8

Jumper
Position
010 VDC
014 VDC
0100 VDC

Connection Diagram
1

DC Current Input

Input Common

2
1

TB40

REV

BI-Polar
Isolation
Option

TB41

CW
FWD

Speed

0 to 10 VDC

Operation and Adjustment


Jumper Selection
Select input range
For voltage input, connect
input wires to the V IN and
COM (common) positions on
TB40. Jumper J40 as follows:

16

Ribbon Cable to Q7000

DC Voltage Input

Voltage
0 to 10 VDC
0 to 14 VDC
0 to 100 VDC

Trim
(Optional)
CW
W
CCW
V Out

2. Specifications
A. Adjustable Instantaneous or
Timed Overcurrent Trip.
Current trip setting 30 to
150% rated current.
B. Adjustable Overvoltage Trip.
Voltage trip setting 10 to
150% rated voltage.

Component Location
Fault Trip Level Adjustment:
Overcurrent
Overvoltage

Fault Relay
Contact

Voltage
Input
Range

Over
Voltage

0 to 10 VDC
1 to 14 VDC
0 to 100 VDC

OV

TB30
1
2
3
4
5
6
7
8
9

For current input, connect input


wires to the I IN and COM
(common) positions on TB40.
Jumper J40 as follows:
Jumper Position
15mA DC
420mA DC

U1

K30

U3

U4
1

TBI

TP33

P30

Com

TB31
1
2

J30
16

Field

PM
SH

Ribbon Cable
to Q7000

Motor Field
Input
Connect in
Series with
Motor Field

Motor Field Select:


Permanent Magnet (PM)
Shunt Wound (SH)

Overcurrent
Indication
Remote
Reset
(Optional)

TB30

Stop

Start

1
2
3
4
5
6
7
8
9

9 10 11
TB1
Q7000 CONTROL BOARD

P31

P32
FAULT
MODULE

P30

Motor
TB31 2
Field
1
F1
F2
2

F1 F2
P4

Q7000
POWER COMPONENT
ASSEMBLY

Notes:
1. Fault relay contacts are shown in
trip or power off condition.
Connect contact in series with stop
circuit as shown to activate stop
function when trip occurs. If this
connection is not made, control is
disabled when trip occurs and will
start when trip circuit is reset.
2. No connection is required for PM
motor.
3. Close contacts to reset trip circuit.
4. Overcurrent indication: Open
collector output sinks up to 250mA
if current exceeds overcurrent
level. (24 VDC max.)

Quadraline 7000

11

10

Quad7 spreads

Overcurrent
Trip Select:
A Timed
B Instantaneous

TP30

Q7000 CONTROL BOARD

Quadraline 7000

J31

U6

K30

P4

1. If optional trim pot is used,


remove jumper from TB413
and 4.
2. Mounted on the enclosure
door of External Signal
Models equipped with this
provision.

B A

+24V

Connection Diagram

Remote Reset
Quick Connect

P32

U5

AUTO

P31

SW30

R31

Fault
Relay
P40

OC

Local
Reset

U2

FL

Reset

Fault
Module

K30

Options
Fault
Module

Trip

Fault
FaultModule
Module
R30

C. Field Loss, detects loss of


field current.
D. Fault Relay, with 2 form C
contacts, that is energized
when power is applied and no
faults are present.
E. Open Collector Output
signifying an overcurrent
condition is present. Timed
overcurrent trip will occur if
the overload remains
(Overcurrent LED D30
indicates output is on.) This
circuit can handle 250mA (24
VDC max.) when the output is
pulled down to zero during an
overload.
F. Four Red LEDs
1. Overcurrent Trip
2. Overcurrent voltage
3. Field Loss Trip
4. Overcurrent Present

Fault Trip
Indication LEDs
OV Overvoltage
FL Field Loss
OC Overcurrent

Overcurrent
Indication LED

Over
OC
Current
TP31

TP32

Ensure Jumper J41 is in


postion A.

MAN

Two form C contacts are provided


from the fault relay that change
state in the event of a fault trip.
An on-board reset pushbutton or
quick connect connections are
provided for resetting the drive
after a fault occurs. When a fault
occurs, the drive is disabled,
turning off the SCR power bridge,
the motor will coast to a stop. If
the fault relay contacts are wired
into the stop circuitry, the Stop/
Start relay in the Quadraline 7000
controller will drop out.

10

3/25/05, 1.18

Quadraline 7000

Options
Independent
Acceleration
Deceleration

Quadraline 7000
1. General Description

The second, Mode B, allows two


different Accel/ Decel rates to be
selected by an outside sourced
contact closure. Like the Basic
Quadraline 7000 the Forward
Acceleration and Reverse
Deceleration rates are identical
as are the Reverse Acceleration
and Forward Deceleration rates.
The Mode B difference allows the
ability to switch through contact
change from either of two sets of
adjustments, thereby giving two
entirely different rates rather than
the single rate allowed with the
basic Quadraline 7000 controller.

The standard Q7000 Series DC


controller has a single forward
acceleration adjustment pot and
single reverse acceleration
adjustment pot. The Forward
Acceleration pot also sets the
acceleration rate in the forward
direction, and the deceleration rate
in the reverse direction, i.e. both of
these rates will be the same.
Conversely, the Reverse Acceleration pot also sets the deceleration
rate in the Forward direction,
again, both rates are the same.
Two modes of Accel/Decel control
can be programmed with this
option.

The adjustment setting for


acceleration determines the
amount of time the motor
controller will take to drive the
motor from standstill or zero
speed up to maximum speed.
The adjustment setting for
deceleration determines the time
the motor controller will take to
brake the moter from maximum
speed to zero.

The first, or Mode A, provides two


acceleration adjustment pots and
two decelation adjustment pots.
This allows for independent
adjustment of the forward acceleration rate, forward deceleration
rate, reverse acceleration rate and
reverse deceleration rate.

2. Specifications

Installation

A. Accel/Decel Time Range:


Jumper Selectable for each
pot
(J21J24)
F Range .33 seconds (zero
to full speed)
S Range 330 seconds (zero
to full speed)
B. Operating Modes:
Jumper Selectable (J20)
A Mode:
Acceleration Forward R21
Deceleration Forward R20
Acceleration Reverse R22
Deceleration Reverse R23
B Mode:
Pot operation in the B Mode
is controlled by a contact
closure or jumper on TB20.

Each version of the Q7000


control except the Q7006 has
provision for mounting up to two
option boards. Q7006 units have
room for one option board. If one
option board is fitted it will be in
postion A in Figure A. The
second option board will be fitted
in position B. Reference Figure A.

Options
Factory or
Field
Installed

Component Location
Time
Range
Select
F .33 sec.
S 330 sec.

Forward
Deceleration
Adjust

Forward
Acceleration
Adjust

Reverse
Deceleration
Adjust

Reverse
Acceleration
Adjust

Location A
Fwd
Decel

Fwd
Accel

R20

Rev
Accel
R21

CW

F
S

CW

F
S

J21

R22

CW

U1

R23
CW

F
S

J22

Operating
Mode
Selection

Rev
Decel

J23

U4

F
S
J24
A
B

U3

J20

TB20

Operating
Mode B
Control

Location B
P4
Logic Board

C7

Independent
Independent
Acceleration
Acceleration
Deceleration
Deceleration

P20
1

16

Ribbon Cable
to Q7000 Control Board

Connection Diagram

A. For field installation of one


ACCEL/DECEL
OPTION BOARD

J20

2
2
1

A
B

P20

P4
A

TB20

Operating
Mode B
Control
Switch
(Optional)

Notes:
1. Jumper J3 on Q7000 control board
must be placed in the center
position as shown for proper
operation of accel/decel option
board.
2. Reference section 2.b for
description of operation modes.

option, the correct mounting


hardware will be supplied with
the option kit.

B. For field installation of two


options, an additional
mounting kit Q709800 for
location B is required.

J3

1
A
Q7000 CONTROL BOARD

Quadraline 7000

Quadraline 7000

12

Quad7 spreads

3/25/05, 1.17

Quadraline 7000

Zero
Position
Dancer
Control

Quadraline 7000
Connection Diagram

Winder
Dancer
Roll

Pivot
Point
Sensor
Motor

1. General Description

2. Specifications

The AC/Pulse Tach Option board


allows the use of either an AC
tachometer or a magnetic pulse
tach for speed feedback to the
Q7000. A ring tach, such as the
MTK series used with the DS
9000 Digital Front End, can be
used. The standard drive requires
a DC analog tachometer 7 VDC/
1000 RPM, or 50 VDC/1000
RPM, if a tachometer is to be
used. If an encoder is to be used,
please consult Seco Electronics
for adjustment.

Input Signal
Primarily designed for 60 pulse
per revolution pulse
tachometers. Maximum
frequency input is 3600 Hz.
Minimum frequency for full
output voltage is 1200 Hz.
Maximum voltage 100V.

Options
A/C Pulse
Tach
Feedback

Output signal
0 to 10 VDC.

Component Location
GND

L1 L2

Maximum
Speed
Adjustment

Offset
Adjustment

A1 A2 F1 F2

Q7000 Heatsink Assembly

R
4
0
7

TB1

Offset

Max Spd

AC Pulse Tach Feedback

9 10 11

TB1

Q7000 Control Board

Input
Signal
from
Pulse/
Tach

V
Out

V
In

U1

TB41

U2
1

Com
1

TB40

TB52

Gain

C2

J6

C4

6
4

R5
R10
TP
2

R4

U1

J50

230V

J51

115V

L1
TB53

Z1

J53

Quadraline 7000

The zero position dancer option


board provides dancer control for
either an unwind, rewind or infeed tension control systems. In a
dancer system, closed loop
control is accomplished because
the web completes the path
between the motor and the
dancer. With the zero position
dancer option board, (hereafter
referred to as the ZPD Board) the
dancer remains in a fairly
constant position throughout the
run.

The purpose of the ZPD board is


to stabilize the system and keep
the dancer in a fixed position,
thus maintaining tension within a
given tolerance range.
The pivot-point sensor, coupled
to the pivot point of the dancer
arm, generates a signal to the
ZPD board signifying the position
of the dancer arm and the
direction and velocity of any
dancer arm movement. The
Dancer Position potentiometer
adjusts the dancer zero point
electrically within the control.
Terminals are provided for a

T856

VR5

P40

TP40

Proportional
Gain
R24 TP
6
R23
Derivative
Gain
R33

16

Ribbon Cable to Q7000

P
VR4

5
6

I
VR6

7
8
9

Connection Diagram

ABC

remotely mounted Dancer


Position potentiometer.
The adjustments contained on
the ZPD board enable the system
to be fine tuned to the exact
parameters of the application to
provide optimum control and
stability.

2. Specifications
Dancer pot (Pivot point sensor)
1k OHM min., 20k OHM max.
M/N APT 2043-00

R40
Offset

AC Tach
60 Pulse/Rev
3600 RPM Max
T

R42
Max Spd

3
3 V
In
2
1 Com
TB40

1
TB1
7V
J1
50V
1

Max
Spd
R1

Arm
SW1
Tach

2
1
TB41

AC/PULSE TACH
FEEDBACK OPTION
P40

V Out

Notes:
1. Place jumper J1 in 7V position.
2. Select tach feedback mode. (SWI)
3. Adjust R42, max. speed to set
maximum motor speed. (R1, max.
speed on Q7000 control board
should be set fully CCW)

P4

3
Q7000 CONTROL BOARD

Quadraline 7000

13

Quad7 spreads

TB54
L52

J54
ABCD

U8

RC1

1. General Description

TP
7

U4

J52

T856

U3

TP
5
115V

U7

U2

F1

L2

Derivative
TP Gain
4
R28 TP
TP R26 9
8

TP3
TP
1

R6

U6

11

U3

T856

TP
10

4
+

Output
Signal

U5

CO

SW1

01

CG

Dancer Position
VR1

R2

OT

TP
11

P50

VR2

J4

COM +

D51 TB50

OS

R56

L52

R55

L51

R54

R50

R53

R52

R51

Open

R
4
2

3/25/05, 1.17

Quadraline 7000

Remote
Operator
Stations

Quadraline 7000
Quadraline 7000 Series

Remote Operator Stations (ROS)


Function

Model
Number

Start-Stop Switch (2)


Run-Jog Switch
Forward-Reverse Switch
Auto-Manswitch
Single Turn Speed Pot
Start-Stop Switch (2)
Run-Jog Switch
Auto-Man Switch
Single Turn Speed Pot
Start-Stop Switch (2)
Forward-Reverse Switch
Run-Jog Switch
Single Turn Speed Pot
Start Pushbutton (1)(3)
Stop Pushbutton
Single Turn Speed Pot

R1000

R1001

R1002

R8005

Input
Input
Line
Line
Voltage

HP

115 VAC
1 Phase

Basic On/Off

Zero Position
Dancer Control

Chassis NEMA
4/12

NEMA
Chassis
4/12 w/
Operators

NEMA
4/12

NEMA
Chassis
4/12 w/
Operators

1/81/2

Q7006

N/A

N/A

Q70061

N/A

N/A

Q70065 N/A

230 VAC
1 Phase

1/41

Q7006

N/A

N/A

Q70061

N/A

N/A

Q70065 N/A

115 VAC
1 Phase

1/41

Q7002

Q7022

Q7032

Q70021

Q70221 Q70421

Q70025 Q70225

230 VAC
1 Phase

1/22

Q7002

Q7022

Q7032

Q70021

Q70221 Q70421

Q70025 Q70225

230 VAC
1 Phase

35

Q7005

Q7025

Q7035

Q70051

Q70251 Q70451

Q70055 Q70255

Run/JogForward/Reverse
Includes power unit, control logic
and enclosure if specified with or
without operator devices.
Operator devices include: StartStop switch, Run-Jog switch,
Forward-Reverse switch, single
turn Speed Setting Potentiometer
and Power Light.

Note:
(1) NEMA 12 Enclosed with wiring to operators.
(2) NEMA 4/12 Enclosed with wiring to terminal strips.
(3) For non-reversing application only.

External Signal

External Signal
Includes power unit, control
logics, isolated signal follower
accepting 420 mA, 1 5mA, 0
10 VDC, 0 14 VDC or 0
100 VDC reference signal
inputs and enclosure if specified
with or without operator devices.
Operator devices include: StartStop switch, Run-Jog switch,
Forward-Reverse switch, AutoManual switch, single turn Speed
Setting Potentiometer, and Power
Light.

Selection
Information

NEMA
4/12

Zero Position Dancer Control


For tension applications such as
an unwind, rewind or tension
infeed with a zero position dancer
or load cell includes PID function.
This feature is used in special
applications usually involving
web-processing equipment.

Options

Isolation
Transformers

Description

Isolation Transformers
Single phase NEMA I Enclosed, Dry Type, No Taps, 60 Hz
HP

KVA

Primary
Voltage

Secondary
Voltage

Model Number

1/4

1/2

120/240

120/240

TRS21-005

1/2

120/240

120/240

TRS21-010

3/4

11/2

120/240

120/240

TRS21-015

120/240

120/240

TRS21-020

11/2

240/480

120/240

TRS42-030

240/480

120/240

TRS42-050

71/2

240/480

120/240

TRS42-075

10

240/480

120/240

TRS42-100

For dimensions and connection information, contact Warner Electric Motors and Controls customer service.

Quadraline 7000

Factory
Installed
M/N Suffix

Field
Installed
Kits M/N

Q799901

Fault
ModuleContact outputs
.
-trips on overcurrent,
overvoltage or field loss.

Q799902

Independent Accel/Decel
ControlForward accel,
forward decel, reverse accel,
reverse decel, 4 potentiometers

Q799903

AC/Pulse Tach Feedback


Converts signals from AC
tachometer or pulse generator to
direction sensitive DC voltage for
improved speed regulation

Q799904

Mounting and connecting


hardware for 2 option kits

Not
Required

Q7098-00

Pivot Point Sensor


(for use w/zero position
Dancer controlled models)

APT 2043-00

Isolated InputBipolar,
input-output with selectable
inputs for 0 to 10 VDC, 0 to 14
VDC, 0 to 100 VDC, 1 to 5mA
or 4 to 20 mA.

14

Quad7 spreads

Quadraline 7000

3/25/05, 1.17

Quadraline 7000

Quadraline 7000

How to Order

How to Order
In determining the components
that comprise a drive system, the
following selections must be
made for features and options.

1. DC Motor Controller

4. Isolation Transformer

Select HP and AC input voltage.


The AC input voltage will
determine motor armature and
field voltage.

Select KVA of transformer when


required by adding the total HP of
all drives to be connected to the
transformer. Then select model
number by primary input voltage
and secondary output voltage.

AC Input
Voltage

Motor Voltage
Arm/Field

115V

90V Arm
50/100V Field
180V Arm
100/200V Field

230V

Now select drive configuration,


chassis or enclosure. If enclosure, do you want a blank front
cover or operators controls?
Determine which operators are
required (i.e., run/jog, auto/
manual) and whether they will be
on a remote operators station or
on the drive enclosure. From the
list of standard option boards,
select those required for your
application.

2. DC Motor
With the motor voltage specified
by the AC input voltage selected
above, now determine permanent
magnet or shunt wound, frame
size, enclosure type (TEFC or
TENV), C face, and whether a
tachgenerator will be required.

3. Remote (ROS) Operator


Station

Selection charts for DC motors,


available from Warner Electric
Motors and Controls, are listed on
the following pages. For more
complete specifications and
dimensional information, contact
Warner Electric Motors and
Controls customer service.

5. Options/Accessories
A. Determine which options are
required for your applications.
This could include speed and/
or load meters.
B. Options may be mounted by
the factory or field installed.

Motor chart specify:


Horsepower
Motor Type (Manufacturer)
B=Baldor
G=General Electric
Frame Size
Motor Enclosure
TE=Totally Enclosed
TEFC=Fan Cooled
TENV=Non Ventilated
C Face Size
(For use with Single Phase
Controllers only)
Armature Voltage
Model Number
Motor with Tachometer
(mounted)
Motor without Tachometer
Tachometer Kit

Non-Listed Motors
Non-listed motors are available,
but specific information is
required.
1. Motor horsepower
2. RPM
3. Frame size
4. Volts, armature
5. Volts, field or PM
6. Enclosure
7. Conduit location, F1, F2 etc.
8. Thermostat
9. Accessory endshield
10. C face
11. Delivery requirements
12. Special application or
environmental considerations
and other important
information.

Standard
DC Motors

Example
A conveyer requires a 1 HP DC
motor, 1750 RPM, shunt wound
field, TEFC enclosure and a
7V/1000RPM tachometer. The
DC drive will be chassis mount,
230 VAC single phase input, to
be operated from a ROS. ROS to
include forward and reverse,
start/stop and a speed potentiometer. Isolation transformer from
a 230 VAC input is required. The
user would also like fault output
contacts to activate other
machine control.
Item

Qty

1
2
3
4
5

1
1
1
1
1

Part No.
Q70062
MOH2210831
R1002
TRS21020
(included as a
part of item 1)

If a remote operators station will


be used, select which operators
will be used, and the NEMA
rating required.

Quadraline 7000

Quadraline 7000

15

Quad7 spreads

3/25/05, 1.17

Quadraline 7000

Standard
DC Motors

Quadraline 7000
DC Motors

Specification

1/4 to 1 Horsepower 90 VDC Armature PERMANENT MAGNET FIELD 1750 RPM Totally Enclosed
NEMA
Enclosure C
Face

Q7006

Q7002

Q7005

1/81/2
1/41
115 or 230 V 10%
50/60 Hz 2 Hz
Single Phase

1/41 HP
1/22 HP
115 or 230 V 10%
50/60 Hz 2 Hz
Single Phase

Not Used
35 HP
115 or 230 V 10%
50/60 Hz 2 Hz
Single Phase

Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

Horsepower Range
115V
230V
AC Line Input Voltage
AC Line Frequencey
115 VAC Supply
Armature Voltage
Field Voltage

090 VDC
50/100 VDC

090 VDC
50/100 VDC

Not Applicable
Not Applicable

230 VAC Supply


Armature Voltage
Field voltage
Service Factor
Duty
Maximum Load Capacity
Line Protection
U.L. Listed

0180 VDC
100/200 VDC
1.0
Continuous
150% for 1 min.
Fuses
No

0180 VDC
100/200 VDC
1.0
Continuous
150% for 1 min.
Fuses
Yes

0180 VDC
100/200 VDC
1.0
Continuous
150% for 1 min.
Fuses
Yes

HP

Motor
Type

Frame
Size

1/4

G
B

56HAA
320P

NV
NV

56C
56C

MOD6110210
MOD6211200

N/A
MOD6211231

N/A
TAC 400113

1/2

G
B

56KAA
336P

FC
NV

56C
56C

MOF6210210
MOF6211200

N/A
MOF6211231

N/A
TAC 400113

3/4

G
B

56PAA
428P

FC
FC

56C
56C

MOG6210210
MOG6211100

N/A
MOG6211131

N/A
TAC 400100

G
B

56SAA
435P

FC
FC

56C
56C

MOH6210210
MOH6211100

N/A
MOH6211131

N/A
TAC 400100

Note: All motors are capable of 20:1 constant torque speed range.

Specifications

Q7006

Operating Conditions
DC Motors
1/2 to 5 Horsepower 180 VDC Armature PERMANENT MAGNET FIELD 1750 RPM Totally Enclosed
Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

56C
56C

MOF7210210
MOF7111100

N/A
MOF7111131

N/A
TAC 400113

FC
NV

56C
56C

MOG7210210
MOG7211100

N/A
MOG7211131

N/A
TAC 400110

146ATC
56SAA
435P

FC
FC
FC

140TC
56C
56C

MOH7210800
MOH7210210
MOH7211100

MOH7210831
N/A
MOH7211131

TAC 400402
N/A
TAC 400100

B
G

536P
148ATC

FC
FC

140TC
140TC

MOI7211100
MOI7210800

MOI7211131
MOI7210831

TAC 400701
TAC 400402

B
G

548P
149ATC

FC
FC

140TC
140TC

MOJ7211100
MOJ7210800

MOJ7211131
MOJ7210831

TAC 400701
TAC 400402

G
B

1412ATC
649P

FC
FC

140TC
180TC

MOK7210800
MOK7211100

MOK7210831
MOK7211131

TAC 400402
TAC 400115

681P

FC

180TC

MOL7211100

MOL7211131

TAC 400115

HP

Motor
Type

Frame
Size

Enclosure

1/2

G
B

56KAA
336P

FC
NV

3/4

G
B

56PAA
336P

G
G
B

1-1/2

NEMA
C
Face

Note: All motors are capable of 20:1 constant torque speed range.

Ambient Temperature
Chassis Model
055 C
055 C
055 C
Enclosed Model
N.A.
040 C
040 C
Relative Humidity .................................................... 595% non-condensing ......................................................
Altitude ......................................................................... to 3300 ft. (1000m) .........................................................

Performance Characteristics
Speed Range
50:1
50:1
50:1
Speed Regulation (% of motor base speed) for 95% load change
Arm. Voltage Feedback ................................... 1% to 2% (depending on motor) .............................................
Tach. Feedback ................................... 1/2 to 1% (depending on tach generator) .............................................
Acceleration (forward or reverse)
Range A ..................................................... Linear .33 seconds (to full speed) ...........................................
Range B .................................................... Linear 330 seconds (to full speed) ...........................................

Adjustments
Q7005

Current Range
(nominaladjustable to 150%)

1.0, 1.5, 2.0, 3.0


2, 3, 4, 6, 10, Amps
15, 25 Amps
5.0 Amps
Maximum Speed ................................................. 70105% of motor base speed ...............................................
IR Compensation .............................................................. Adjustable .................................................................

Options

Description

Isolated Input

Bipolar, inputoutput with selectable inputs for 0 to 10 VDC, 0 to 14 VDC,


0 to 100 VDC, 1 to 5mA or 4 to 20mA
Contact outputstrips on overcurrent, overvoltage or field loss
Forward acceleration, forward deceleration, reverse acceleration, reverse
deceleration, 4 potentiometers
Converts signals from AC tachometer or pulse generator to direction sensitive
DC voltage for improved speed regulation

Fault Module
Independent Acceleration/
Deceleration Control
AC/Pulse Tach Feedback

Quadraline 7000

Quadraline 7000

16

Quad7 spreads

Q7002

3/25/05, 1.17

Quadraline 7000

Applications

Quadraline 7000
Material Handling

DC Motors

1/4 to 1 Horsepower 90 VDC Armature 100/50 VDC SHUNT WOUND FIELD 1750 RPM Totally Enclosed

Controlled acceleration
Controlled deceleration
Bi-directional
Precise positioning accuracy

HP

Motor
Type

Frame
Size

1/4
1/2
3/4
1

B
B
B
B

413D
420D
428D
535D

Enclosure

NEMA
C
Face

FC
FC
FC
FC

56C
56C
56C
56C

Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

MOD1211700
MOF1211700
MOG1211700
MOH1211700

TAC 400100
TAC 400100
TAC 400100
TAC 400700

MOD1211731
MOF1211731
MOG1211731
MOH1211731

Standard
DC Motors

Note: All motors are capable of 20:1 constant torque speed range.

Machine Tools
4 quadrant control allows
positioning easily adapted to
specific program needs

DC Motors
1/2 to 5 Horsepower 180 VDC Armature 200/100 VDC SHUNT WOUND FIELD 1750 RPM Totally Enclosed
Model Number
Motor
Motor with
without
7 VDC/1000 RPM
Tachometer
Tachometer
(mounted)

7 VDC
Tachometer
Kit

56C
56C
140TC
56C
180C
140TC
180C
180C

MOF2211700
MOG2211700
MOH2210800
MOH2211800
MOH2110100
MOI2210800
MOI2110100
MOI2211400

MOF2211731
MOG2211731
MOH2210831
MOH2211831
MOH2110131
MOI12210831
MOI2110131
MOI2211431

TAC 400100
TAC 400100
TAC 400102
TAC 400701
TAC 400203
TAC 400402
TAC 400203
TAC 400115

FC
FC
NV

140TC
180C
180C

MOJ2210800
MOJ2211400
MOJ2110100

MOJ12210831
MOJ2211431
MOJ2110131

TAC 400402
TAC 400115
TAC 400203

NV
FC
FC

180TC
140C
210C

MOK2110100
MOK2210800
MIK2211100

MOK2110131
MOK2210831
MOK2211131

TAC 400203
TAC 400402
TAC 400106

210C
256UCZ

MOL2110700
MOL2211100

MOL2110731
MOL2211131

TAC 400203
TAC 400108

HP

Motor
Type

Frame
Size

Enclosure

1/2
3/4
1

B
B
G
B
G
G
G
B

420D
428D
146ATC
535D
L182ACY
148ATC
L186ACY
636D

FC
FC
FC
FC
NV
FC
NV
FC

G
B
G

149ATC
646D
L186ACY

G
G
B

189ATC
1412ATC
7544D

G
B

CD2110ACY* NV
9143D*
FC

NEMA
C
Face

Web Processing
Accurate web or material
tensioning
Zero position dancer (P.I.D.
Gain Control)
Smooth and consistent control
in process, and during un-wind
or wind-up

1-1/2

Robotics
Economical alternative to
sophisticated Servo control in
less demanding applications
Chassis mount for easy
integration in customer control
panel

*These motors have 1-1/8" shaft diameter.


Note: All motors are capable of 20:1 constant torque speed range.

Quadraline 7000

Quadraline 7000

17

Quad7 spreads

3/25/05, 1.17

Quadraline 7000

Dimensions

Quadraline 7000

Features and
Benefits

Chassis

Q7006 Series

Q7002/7005 Series
.75

.218 Dia. (4)

.187 x .375 slot (2)

11.75
10.25

9.625
9.000
.187 Dia. (2)

7.375
3.375

9.125
9.50

.375
5.50

8.00

Dimensions are listed in inches.

Feature Packed
Enclosed

Q7002/7005 Series

Full wave 4-quadrant operation


Provides smooth motoring or
braking torque in either direction
of rotation.

.218 Dia. (4)

10.25

7.562
8.375

7 Selectable performance
features

13.00

8.750
9.50

115V/230V AC Input
Accel/Decel Range
Internal/External Jog Reference
HP Select
Overcurrent Trip Select
Timed/Instantaneous/Disable
Motor Field Type
PM or Shunt Wound
Feedback Type
High-response drive
Wide-band width allows unit to
replace expensive servo drives in
some applications.

Electronic reversing

115/230 VAC Input

Regenerative braking
Motor acts as a generator and
produces braking torque.

Positioning accuracy
4 quadrant control provides
positioning easily adapted to
specific programming needs.

7 Control adjustments
Max. speed, forward and reverse
acceleration, IR compensation,
forward and reverse current limit,
response characteristic.
For use with shunt wound or
permanent magnet DC motors

Total control
Controlled acceleration and
deceleration. Smooth, consistent,
accurateideal for web
tensioning applications.
* Chassis or NEMA 4/12
enclosure

Complete electrical protection


1/4 to 5 HP
150% full load current available
for 1 min.

Listed

Listed for use in Canada

Dimensions are listed in inches.

Quadraline 7000

*All units except Q7006

18

Quad7 spreads

Quadraline 7000

3/25/05, 1.17

High-response drive
Wide band width allows unit to
replace expensive servo drives in
some applications.
Regenerative braking
Motor acts as a generator and
provides braking torque.
The braking energy is returned to
the AC power line, not dissipated
as heat.
Electronic reversing
Allows rapid and continuous
cycling without any moving parts
in the control.
No mechanical contactors
required.

L1

L2

A1

A2

Rev. ()

F1

F2

Stop

F2
TB2

P2

P1

A2

1
GND

W
CCW

TB1

2
7V

10

11

Arm

J1

SWI
50V

Tach

CONTROL PC BD.

115V

HEATSINK ASSY.

J9 J10
90V

180V
J11

Notes:
1. Ground control per local and
national codes.
2. Customer supplied line fuses;
size for protection of AC line
wiring and transformer per
local and national codes.
3. Programming jumpers J9,
J10, and J11 on control board
must be positioned for 115 or
230 VAC line.
4. Polarity shown is for positive
speed reference voltage at
TB14 (fwd direction).
5. For PM motors, no
connection is necessary to F1
and F2.
6. DC tachometer (7VDC/1000
RPM or 50 VDC/1000 RPM)
is optional; when used, select
tach feedback mode (SW1)
and tach voltage level (J1).

Protection
Input AC line fuses protect
control from line or load faults.
MOVs protect unit from voltage
transients on AC power line.
Optional features include:
NEMA 4/12 enclosure
Fault module
Bi-polar isolated input module
Independent Individual control
of forward accel and decel and
reverse accel and decel rates
AC pulse tach feedback

Quadraline 7000

7. Speed adjust potentiometer:


2K to 10K.
8. Selector switch determines
direction of motor rotation.
For Bi-directional operation
without switch. Connect CCW
potentiometer lead to TB16.
9. TB17 and 8 must be
connected together to enable
control; jumper is factory
installed. Open this circuit to
disable control.
10. Start (n.o.) and stop (n.c.)
momentary pushbuttons are
used for conventional 3-wire
control. If 2-wire control is
required, connect maintained
switch or contact between
TB19 and TB111.
11. If motor thermostat (P1, P2) is
available, connect in series
with stop pushbutton as
shown.

Quadraline 7000

19

Quad7 spreads

+ F1

+ A1

11
10

CW

Start

115/230 VAC

230V

Selectable features
Selected by programming
jumpers to program drives for
specific motor or application:
AC Supply selects 115V or
230 VAC
Current Scaling selects current
range to match control to a
particular motor HP Rating
Speed Feedback selects
armature voltage feedback or
tachgenerator feedback for
improved speed holding
Acceleration/Deceleration Time
selects range for adjustment
control up to 30 secs
Torque or Speed Control selects
mode of either motor speed or
motor torque controlled by
operators potentiometer
AC Supply Frequency allows
drive to be operated on 50 Hz
or 60 Hz supply

Adjustments
Customer adjustments to match
control to application:
Maximum speed limits speed
available at operators control
Forward Acceleration sets time
to reach full speed in forward
direction is also reverse
deceleration time
Reverse Acceleration sets time
to reach full speed in reverse
directionis also forward
deceleration time
IR Compensation improves
motor speed regulation in
armature feedback mode
Forward Current Limit sets
maximum current available in
forward direction to limit motor
overload
Reverse Current Limit sets
maximum current available in
reverse direction to limit motor
overload
Response sets response
characteristic of control for
higher performance
applications

Connection
Diagrams

Fwd (+)

Full wave four quadrant


operation
Provides smooth motoring or
braking torque in either direction
of rotation.

UL Listed Ratings
Horsepower range
115 VAC
1/41 HP
230 VAC
1/25 HP
150% full load current available
for 1 minute.

230V

Designed for either permanent


magnet or wound field motors
Field supply is standard.
Allows use of a wide range of
motors.

115V

The Quadraline 7000 series is a


full wave, regenerative DC drive
designed to operate shunt wound
or permanent magnet DC motors
from 1/4 HP to 5 HP.
Regenerative drives are the ideal
answer for:
Maintaining motor speed
when an overhauling load
attempts to increase the
motor speed
Providing continuous
braking torque with no power
dissipation
Repeatable, controllable
braking to rest
Rapid, repetitive reversal of
motor rotation
The Quadraline 7000 models are
packed with features, designed
and manufactured to the highest
quality standards and available
from your local Warner Electric
Motors and Controls distributor at
an economical price.

Speed adj.

Features and
Benefits

Quadraline 7000

DC tach
100 VDC max.

Quadraline 7000

3/25/05, 1.16

Quadraline 7000

Connection
Diagrams

Quadraline 7000

Contents

Shunt Field Connections for DC Motors


L1
DC MOTOR
CONTROLLER L2

L1
DC MOTOR
CONTROLLER L2

Line input
115 VAC

A1

DC motor
armature
90 VDC

A1
A2
F1

A2

DC motor
armature
90 VDC

Contents

DC motor
shunt field
50 VDC

Features and Benefits . . . . . . . 2

F1

DC motor
shunt field
100 VDC

F2

Line input
115 VAC

F2

Applications . . . . . . . . . . . . . . . 4
Connections for a DC motor with a
90 VDC armature and 100 VDC
shunt field.
L1
DC MOTOR
CONTROLLER L2

Connections for a DC motor with a


90 VDC armature and 50 VDC
shunt field.
L1
DC MOTOR
CONTROLLER L2

Line input
230 VAC

A1
A2
F1
F2

DC motor
armature
180 VDC

A1

DC motor
shunt field
200 VDC

F1

Adjustment
Locations

F2

Speed Arm

J1
Tach
Range

Zero Position
Dancer Control . . . . . . . . . . . . 8

DC motor
armature
180 VDC

Options
Installation . . . . . . . . . . . . . . 9
Bipolar Isolation . . . . . . . . . 10
Fault Module . . . . . . . . . . . 11
Independent Acceleration
Deceleration . . . . . . . . . . . 12
A/C Pulse Tach
Feedback . . . . . . . . . . . . . . 13

DC motor
shunt field
100 VDC

Remote Operator
Stations . . . . . . . . . . . . . . . . . 14

7 8 8 9 10

R1
7V
50V

Selection Information . . . . . . . 7

Connections for a DC motor with a


180 VDC armature and 100 VDC
shunt field.

1 2 3 4 5 6

TB1

How to Order . . . . . . . . . . . . . . 6

Line input
230 VAC

A2

Connections for a DC motor with a


180 VDC armature and 200 VDC
shunt field.

Specifications . . . . . . . . . . . . . 5

R2

R3

Accel

R4

R5

R6

R9

R8

Bias
Torque Tach Accel (Factory
J3
set)
J2 SW1

R7

A=.3-3 sec
B=3-30 sec

J4

TB1
60 HZ
50 HZ

J5

Accel
Range

p 13
7 pt helv; .5 line

R1Max speed
R2IR comp
R3Fwd accel
R4Rev accel
R5Fwd I limit
R6Rev I limit
R7Response
R9Zero Speed

Isolation Transformers . . . . . 14
Standard DC Motors . . . . . . . 15
Dimensions . . . . . . . . . . . . . . 18
Connection Diagrams . . . . . . 19
Adjustment Locations . . . . . . 20

R69
A

Recommended Spare
Parts . . . . . . . . . . . . . . . . . . . 21

R76A
Offset
(Factory set)

Service . . . . . . . . . . . . . . . . . 21

R103

D
B

P4

C
A

J6

Current
Range

Line Voltage Select

P3

115V 230V

J9

230V 115V

P2

J10
90V

P1

Quadraline 7000

180V

J11

Quadraline 7000

20

Quad7 spreads

3/25/05, 1.16

ADDITIONAL WARNER ELECTRIC DC DRIVES & CONTROLS


Quadraline 7000

Recommended
Spare Parts

Recommended Spare Parts

BRONCO II and Washdown Series DC Drives

SE2000 DC Drives

Designed for tough rugged applications, BRONCO II DC


Drives feature speed regulation 0.5 1%, dual voltage
input (115/230 VAC), output 90 or 180 VDC, to 2 HP,
circuit protection, torque control, local or remote operator
control, open chassis, field programmable jumpers,
control relay with 3-wire start/stop circuit, jog at
potentiometer speed, cast aluminium enclosure NEMA
4, NEMA 12, and NEMA 4X. Maximum and minimum
speed adjustments.

This non-regenerative DC drive is designed to control


shunt wound or permanent magnetic field DC motors
from to 5 HP. It offers isolated 4-20mA or 0-10 VDC
control signal, tachometer generator feedback, circuit
protection, diagnostic capabilities, control relay, torque
and slope control, and overcurrent protection. Jumper
selectable to program drives for specified motor or
application. Horsepower range 115 VAC to 230 VAC.
Open chassis available and UL listed.

Warner Electric
Part Number
Q7005

Description

Q7002

Q7006

Control Board Assembly*

SPC3593300

SPC3593300

SPC3593300

Line Fuse (F1, F2)

PFU101701
226636-001
(Buss JJN30A)

PFU101700
226636-000
(Buss JJN60A)

PFU101000
104364-022
(MDA15A)

Control Fuse (F3)

PFU100400
(AGC.25A)

PFU100400
(AGC.25A)

PFU100400
(AGC.25A)

SCR Module

SPATY401800

SPATY401700

Field Bridge

226122-000 PDI500500

PDI500500

MOV

202956-014 PSU200200

PSU200200

Power Board Assembly

SPC3601900

Zero Position Dancer


Control Board Assembly

Q799905

Q799905

Q799905

External Signal Option


Control Board Assembly

Q799901

Q799901

Q799901

Fault Module Option


Control Board Assembly
Independent Accel/Decel Option
Option Control Board Assembly
AC/Pulse Tach Feedback
Control Board Assembly

Q799902

Q799902

Q799902

Q799903

Q799903

Q799903

Q799904

Q799904

Q799904

* When replacing the Control Board Assembly, it is essential that all of


the set-up jumpers and adjustment potentiometers on the new board
are identical to those on the board being replaced. It may be
necessary to re-adjust the potentiometers on the new board for correct
operation. See Section 3.0 of this Manual.

Service

M4000 Digital 3-Phase DC Drives

DS9000 Digital Drive Speed Controller

The M4000 Series Digital 3-Phase DC Drive is a


programmable, microprocessor based variable speed DC
drive. It allows keypad control of each parameter. Digital
readout provides on-line monitoring of drive operation.
Ideal for many drive applications including wire and
cable, packaging/converting, machinery and material
handling. Improved circuit board technology has added
standard features, including serial communications and a
field-weakening controller for constant power and
extended speed range applications.

The DS9000 Digital Speed Controller features long term


speed accuracy, control and stability. It offers 16-bit
microprocessor based, AC or DC drive control, .01%
accuracy, digital master or follower, analog or digital
input, and two selectable sets of programmable parameters. Front panel controls include a 4-digit LED readout,
keypad controls and four LED status indicators.

Service

It is intended that the


Quadraline 7000 should be
serviced by replacing major
sub-assemblies. The Replacement Parts List lists all of the
sub-assemblies required to
service Quadraline 7000
drives. It is recommended that
users keep these parts readily
available to support the drives
critical applications.
For additional assistance
or the name of your
closest authorized service
center, contact Warner
Electric Motors and Controls
customer service at (800)
787-3532.

Quadraline 7000

*Contact Warner Electric for information on our complete line of AC Drives

Quadraline 7000 Cover

21

3/25/05, 1.09

AR
SUPPORTED BY DANA CORPORATION

CTR

The Warner Electric Motors and Controls Division of Dana Corporation is a global leader in the engineering and manufacturing of motor and control products for industrial applications. All Warner Electric
products and services are backed by highly specialized engineers and service people who can help solve
your production challenges. Warner Electrics capabilities and products have improved operations for
hundreds of companies around the world.
Warner Electric stepper motors and controls, servo motors and controls, voltage conditioning products,
engineered systems, and AC/DC drives are available worldwide through an extensive authorized distributor network. These distributors provide convenient service by offering technical support, replacement
parts, and literature, as well as an extensive inventory of off-the-shelf models for the fastest possible
delivery and service. Call your nearest distributor for ordering and application information.

Quadraline 7000
DC Drives

IN U.S.A. AND CANADA


Distributed by ELECTRO SALES CO., INC.

Sales and Quote: 617-666-0500

Customer Service: 800-787-3532

Product Application: 800-787-3532

Product Literature Request: 800-787-3532

Fax: 617-628-2800

Web Site: www.electrosales.com/warner

WARNER ELECTRIC MOTORS AND CONTROLS DIVISION


Division Office
640 Avis Drive, Suite 200
Ann Arbor, MI 48108

C3003

Quadraline 7000 Cover

Bristol Plant
383 Middle Street
Bristol, CT 06010

Systems Center
13500-J South Point Blvd.
Charlotte, NC 28273

SERVO CONTROLS

International - Europe
Lausanne, Switzerland
La Pierreire
CH-1029 Villars-Ste-Croix,
Switzerland

1999 Warner Electric Division


Printed in U.S.A.

9/99

3/25/05, 1.08

STEPPER CONTROLS

VOLTAGE CONDITIONING

ENGINEERED SYSTEMS

AC/DC DRIVES

You might also like