FCP Series

Description

FCP 6000 Series

Explosion proof

and weather proof panel enclosure series


consisting of a set of 7 enclosures. Each enclosure is of
robust construction with adequate metal thickness and
flame paths to withstand any internal explosion. The
enclosure covers are all hinged and have sufficient metal
thickness to carry a wide range of components such as
actuators, switch shafts, ammeter glass housing. Individual
enclosures are interconnected with a range of sealed
explosion proof nipples depending upon the wiring
requirements of each panel. The enclosures are completely
gasketed for providing a high degree of weather proof
protection.
The enclosures are also liberally dimensioned so that a
comprehensive range of switches, contractors, fuse switches
and transformers can be safely mounted and maintained
while all the heat generated is properly dissipated.

FLAMEPROOF PANEL BOARD ENCLOSURE

Type of protection
Area Classification
Gas Groups
Apparatus Standard
Approvals

Mechanical Data
Material
IP Protection
Finish
Cable Entry
Hinge
Gasket
Mounting
Hardware

: Aluminium LM6
: IP 65 as per IS-12063/1987 (IEC 60529/1989)
: Anti corrosive Epoxy powder coated
: Refer cable entry chart
: Stainless Steel (Optional)
: Neoprene
: Wall mounting mild steel framework
: Stainless Steel (SS-304)

S.No.

Catalog No.

Length
(mm)

Width
(mm)

Height
(mm)

Weight
(kg)

CIMFR Cert No.

FCP-6000-1

200

150

100

4.4

CIMFR/TC/SR/396

FCP-6000-2

200

200

150

6.4

CIMFR/TC/SR/396

FCP-6000-3

400

200

155

12.5

CIMFR/TC/SR/396

FCP-6000-4

400

400

175

26.4

CIMFR/TC/SR/396

FCP-6000-4R

400

400

255

33.9

CIMFR/TC/SR/396

FCP-6000-5

600

400

175

37.2

CIMFR/TC/SR/396

FCP-6000-5R

600

400

250

44.9

CIMFR/TC/SR/396

FCP-6000-6R

300

300

250

24.4

CIMFR/TC/SR/H263

FCP-6000-6

300

300

210

19

CIMFR/TC/SR/H263

10

FCP-6000-7

600

300

170

32.4

CIMFR/TC/SR/H263

11

FCP-6000-7R

600

300

250

36

CIMFR/TC/SR/H263

12

FCP-6000-8

375

275

140

20

CIMFR/TC/SR/H1217

Electrical Data
Terminals
Earthing

Flame Proof - Exd


Zone 1 & 2
Group I, II A, II B
IS-2148:2004(IEC 60079-1/2001)
CCE,BIS

: As per the customers specification.


: External : 2 Nos - M6
Internal : 1 No - M5

Cable Entry
FCP-6000-6

FCP-6000-7 FCP-6000-8

0.5

A/B
5

C/D
4

A/B
10

C/D
10

A/B
24

C/D
10

A/B
24

C/D
24

A/B
40

C/D
24

A/B & C/D


18

A/B & C/D


40

A/B
16

C/D
12

0.75

14

14

14

24

14

12

24

13

10

14

14

14

24

14

12

24

1.25

12

12

1.5

12

12

2.5

CIMFR CERTIFIED, CCE & BIS APPROVED

A
C

D
B

www.baliga.com

PANEL ENCLOSURES

ENTRIES FCP-6000-1 FCP-6000-2 FCP-6000-3 FCP-6000-4 FCP-6000-5

Max. Terminals Possible ( size )

Catalog No.
FCP-6000-1
FCP-6000-2
FCP-6000-3
FCP-6000-4
FCP-6000-4R
FCP-6000-5
FCP-6000-5R
FCP-6000-6
FCP-6000-6R
FCP-6000-7
FCP-6000-7R
FCP-6000-8

2.5mm2
50
50
110
110
110
175
175
36
36
175
175
135

4.0 mm2
20
20
45
45
45
75
75
36
36
175
175
135

6.0 mm2
18
18
40
40
40
65
65
30
30
85
85
120

10 mm2
15
15
35
35
35
52
52
20
20
45
45
90

16 mm2
12
12
25
25
25
43
43
16
16
32
32
50

35 mm2
8
8
18
18
18
28
28
12
12
20
20
32

50 mm2 70 mm2 90 mm2


0
0
0
0
0
0
12
12
0
12
12
8
12
12
8
17
17
12
17
17
12
8
8
6
8
8
6
12
12
9
12
12
9
10
10
9

120
mm2
0
0
0
8
8
12
12
0
0
0
0
0

You might also like