HVP connectors
SPP connectors
Connectors
Welcome to
the world of PITZL
This is Pitzl
As a leading full-range supplier for wood connection systems, we are consistently trying to develop and optimise our products
further. The Pitzl range includes post bases, balcony and fence posts, plug-in connector systems as well as post-purlin connections.
Naturally, we also offer individual, custom-made solutions for your specific range of applications.
ETA-11/0295
ETA-10/0413
Holder of approval:
Holder of approval:
Three-dimensional nailing plate (joist end connector for woodto-wood connections, wood-to-concrete and steel connections)
(Valid from: 2013-04-30 to: 2018-01-02)
Manufacturing plant:
Manufacturing plant:
HVP connectors
SPP connectors
SPP post-purlin connectors the ideal solution for tensile connections or wood connections with combined load types, such
as post-purlin connections.
Page 2
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Connectors
Contents
A/ HVP Connectors
1.
General points
p.4
2.
Design concept
p.4
3.
Formulas
p.5
3.1.
Materials
p.6
3.2.
Timber-to-timber connections
p.7
3.3
p.9
4.
Resistance to fire
p.10
5.
p.11
6.
7.
5.1.
p.11
5.2.
p.11
Timber dimensions
p.16
6.1.
p.16
6.2.
Splitting capacity
p.23
Connections to concrete
p.26
B/ Post-purlin connectors
1.
Characteristics
p.27
2.
p.28
3.
p.29
Page 3
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
2. Design
concept
concept,dimensioning
and design.
by calculation assisted by tests.
action
side
the characteristic loads are increased by the safety
the
pacities according to the European Technical Approval ETA-11/0295. partial coefficients (G = 1,35 for permanent actions, Q= 1,5 for
variable actions).
Thanks to a timber or wood-based panel protection on all sides the
on
side
Whereas
the
resistance
the characteristic load-carrying capaciPitzl HVP connectors can verify a fire resistance up to 60min.The cal-
ties
are
reduced
by
division
with
the
coeffi
cient M.
partial
culation concept is to find in Part 4,such as in the European
Technical
Approval ETA-11/0295.
the influence of the service class and the
wood-based
materials
For
load-duration class
For typical material combinations and geometry the characteristic
is additionally to take into account by the modifi
cation coefficient
load-carrying capacity is given in the tables of the Part 5 for Spax
kmod.
screws.
mit
Pitzl HVP connectors can as well be used with screws from other
Page 4
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
(Fundamental combination)
according to EN 1990
EN 1995-1-1
timber
according
= 1,3 for
solid
to
M=
1,25 for glued laminated
timber
according
EN
1995-1-1
to
For
more
information
and
technical
details,
downloads
and
helpful
video
tutorials: www.pitzl.de
Alternatively,
staff are always available for advice:
our competent
+49 8703 9346-0or
to support@pitzl.de
via e-mail
Pfostentrger Stecksystem
galvanisch verzinkt zinip beschichtet
Service class
Load-duration class
Permanent action
Wichtige
Informationen:
Short term action
Instantaneous action
0,60
0,70
0,80
0,60
0,70
0,80
0,50
0,55
0,65
3. Formulas
In the following formulas are given to calculate the load-carrying
capacities,such as they are also to find in the European Technical
Approval ETA-11/0295. So the load-carrying capacity of the connection can be calculated depending on the load-carrying capacity of
the chosen wood-based material, such as the connection geometry
(inclined joist).
Pitzl HVP connectors are designed for use in service classes 1 and 2.
The load-carrying capacities are given for loads in the direction of
insertion (F2),against the direction of insertion (F3) and perpendicular to the direction of insertion (F4) as well as perpendicular to the
connector plane (F1).
The force in the direction of insertion (F2),the force against the direction of insertion (F3) and the force perpendicular to connector plane
(F1) are supposed to act in the joist axis.
The torsion moment from the joist connection must be taken into
account for the design and the storage of the header.
The verification of the connection of the HVP connector to concrete or
steel elements must be led with the given shear force.
The given load-carrying capacities are valid on the condition that all
designed fasteners are built in.The header connections to concrete
or steel elements must be built with at least 2 fasteners in the upper
holes.
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Width
w
[mm]
Height
h
[mm]
Screw
diameter
[mm]
Number of Screws
n90,J
n45,J
n90,H
n45,H
Joist
Header
elim
[mm]
eM
[mm]
eZ
[mm]
e1,J
[m]
e2,J
[m]
e1,H
[m]
e2,H
[m]
8045
25
45
4.5
11
0,022
0,023
8075
25
75
4.5
14
0,055
0,050
8160
45
60
15
0,193
0,261
0,173
0,222
8211
55
110
11
18
40
0,370
0,676
0,360
0,757
8215
55
150
10
13
25
40
0,566
1,58
0,488
1,46
8315
75
150
10
15
25
60
0,675
1,33
0,676
1,50
8320
75
200
12
10
19
34
95
0,986
2,93
0,910
2,77
8420
120
200
82
330
0,319
1,28
0,564
0,978
8425
120
250
95
430
0,444
2,51
0,725
1,63
8430
120
300
113
530
0,610
4,47
0,930
2,56
8435
120
350
10
10
126
630
0,792
7,13
1,18
3,85
8440
120
400
12
12
145
730
1,01
10,8
1,47
5,54
8445
120
450
14
14
163
830
1,26
15,6
1,80
7,71
8450
120
500
16
16
181
930
1,54
21,6
2,17
10,4
8455
120
550
18
18
200
1030
1,85
29,0
2,58
13,7
8460
120
600
20
20
218
1130
2,91
37,9
3,04
17,7
3.1. Materials
www.pitzl.de/bemessungstool
Wood-based materials:
Fasteners:
Wood screws from different manufacturers (according to EN 14592 or European Technical Approval)
HVP connector
Length
4,5
50 - 80
8160 to 8320
5,0
60 - 80
8420 to 8460
8,0
120 - 180
Screws for protection against lifting (Order with A after the connector number)
HVP connector
Length
Type
8075 to 8320
4,0
30
8420 to 8460
6,3
50
Metal anchors from different manufacturers 12 mm (or 16 mm according to structural requirement) in accordance with an ETA based
on ETAG 001
HVP connector:
Aluminium EN AW-6082 T651 according to EN 485 and EN AW-6005A T6 according to DIN EN 755, geometric parameters according to Table 1
Page 6
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Timber-to-timber
connections
3.2.
8460:
to
HVP connectors
HVP
connectors
8420
to
(1)
(2)
for
Loading in the
direction
of
insertion
e
2
lim
(3)
(4)
HVP connectors
to8320:
HVP connectors 8420 to 8460:
8045
(7)
(5)
(8)
(6)
Pfostentrger
Stecksystem
(9)
Wichtige
Informationen:
& 2BCD2>>
* E * ?!"$%
tem acesti omnis adis
re pratior atus. Ga. TaepelXerferorum
alique
solupid
ellest,
facilla niatus quatur? Neseni
anducit
disapedipsam
The protection
against
lifting
is
ensured
aspedita
nonseca
eperiossit autthrough
ex etur sita
dolupta
tistis et aut ipidestior
assunt,hole.
quos
Loading
against
the
direction
of
insertion
a
screw
in
the
corresponding
drilled
Order
with letter "A"
&
>"2
*
(11)
I"$%
!"$%
F7
: "8211A"
Example
& 2BCD * E
42
9 :
*In Einschubrichtung
Schrauben
8 x 180 mm Vollgewinde, Holz GL 28h
mit
**Andere Holzklassen
oder
Schraubenlngen
knnen
Sie
aus
unserem
Statik-Buch,
Page 7
Pitzl
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively,
our competent
are always
available for advice:
DIN
staff
18 800
+49 8703 9346-0 or via e-mail to support@pitzl.de
Metallbau
GmbH & Co. KG
Design Manual
connectors
of
Loading perpendicular to
the direction
insertion
(12)
Where:
h
Height
of
the
connector
plate
in
mm
Angle between
screw
axis
and
grain
direction
ef,J
Penetration
depth
of
the
threaded
part
of a joist screw
depth
ofa header
of
threaded
ef,H
Penetration
the
screw
part
Characteristic
density of the
joist
k,J
k,H
Characteristic
of the
header
density
of theHVP connector
n45,J
Numberof inclined
screws
in the
joist
plate
connector
n45,H
Number
of
inclined
screws
in
the
header
plate
of
the
HVP
plate
n90,J
Number
perpendicular
of the HVP connector
ofscrews
tothe
joist
n
Number
of
screws
perpendicular
to
the
header
plate
of the
HVP connector
90,H
screw,
Fla,J,Rk
capacity
a
joist
Lateral
of
Fla,H,Rk
Lateral capacity
of aheader
screw,
moment
of
My,k
yield
a
screw
Characteristic
fh,k
Characteristic
embedding
strength according to equation (8.15) of Eurocode 5
d Outer
thread
diameter
of
a screw
joist screw,
of an inclined
Fax,,J,Rk
Withdrawal
capacity
header
Fax,,H,Rk
Withdrawal
capacity
of an inclined
screw,
e2
Eccentricity
to thejoist end grain surface
of theforce
F2,Ed with
regard
e
Eccentricity
of
the
force
F
with
regard
45
centre
4,Ed to the
HVP connector
dimension
elim
(see Table
B.1)
eM
M
/F
(for
types
8211
to
8320
see
Table
B.1)
2,Rk 2,Rk
characteristic
M2,Rk
The lower
moment
capacity
of
the
joist
or header connection
Fax,Rk
Withdrawal
capacity
of a moment
arranged perpendicular to the connector plate
screw
eZ
HVP connector dimension (see Table
1)
e1,J, e2,J, e1,H, e2,H HVP
1)
(seeTable
connector
dimensions
Page 8
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Figure 1: Definition of e
und e45
2
(13)
Where:
F1,Ed
F1,Rd
capacity
in
Pfostentrger
F
DesignStecksystem
load F (in the direction of insertion)
galvanisch
verzinkt
zinip
beschichtet
capacity
inloading
F2,Rd
Design
load-carrying
F2 (in the direction of insertion)
case
2,Ed
F3,Ed
F3,Rd
F4,Ed
Design load F4 (perpendicular to the direction of insertion)
capacity in loading case F4 (perpendicular to the
F4,Rd Design
load-carrying
3.3. Timber-to-concrete
or timber-to-steel connections
8211B
to
(HVP
8460B)
(14)
(15)
&'
")( #
*
!"#"$%
+,"#"$%
(16)
Where:
nwww.pitzl.de/video/verbinder/hvp-lehren
Number of fasteners (metal anchors or screws), n90,H 2
90,H& 01 * 2"3 * 45678 9 3:
./
*In Einschubrichtung mit Schrauben 8 x 180 mm Vollgewinde, Holz GL 28h
Fla,H,Rk
Lateral capacity
of a Sie
header
metalStatik-Buch,
anchor or screw
**Andere
Holzklassen oder Schraubenlngen
knnen
aus unserem
das Sie unter info@pitzl.de anfordern knnen, entnehmen.
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
Page 9
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
4. Resistance to fire
If a!"#"$%
fire resistance
is required,the
& '()"#
* +,"#"$% HVP connector plates shall be
protected on all sides by timber or by a wood-based panel of the
thickness afi:
in mm
Where:
ai Required thickness of the timber or the wood-based
2>> * ?!"$%
;panel protection
&
n Design notional @-A
charring rate under standard fire
exposure according to EN 1995-1-2
treq Required time of fire resistance in min, treq 60 min
Page 10
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Tables of load-carrying capacity for screws from other manufacturers are available on demand.
Pitzl HVP connectors are designed for use in service classes 1 and 2
The load-carrying capacities are given for loads in the direction of
insertion (F2),against the direction of insertion (F3) and perpendicular to the direction of insertion (F4) as well as perpendicular to the
connector plane (F1).
The force in the direction of insertion (F2),the force against the direction of insertion (F3) and the force perpendicular to connector plane
(F1) are supposed to act in the joist axis.
The torsion moment from the joist connection has to be taken into
account for the design and the storage of the header.
If the HVP connector is connected to concrete or steel elements,the
load-carrying capacity of the header metal anchors or screws shall be
additionally verified (cf.Part 3.3).The connection to concrete or steel
elements must be built with at least 2 fasteners in the upper holes.
The given load-carrying capacities are valid on the condition that all
designed fasteners are built in.
Fasteners:
Pfostentrger
EN 338:2010-02, Stecksystem
galvanisch
verzinkt
ziniptimber
beschichtet
Glued
laminated
classified GL24h or GL28h minimum
according to EN 1194:1999-05
HVP
Thread
8160 to 8320
8420 to 8460
4,5
Length
ef
50
44
60
54
60
54
Wichtige Informationen:
Full-threaded
5,0
80 (or 70)
61
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Combination Nr.
Screws
Material
[mm]
8045
8075
8160
8320
8420
8460
Header
Fla,J,Rk
[N]
inclined screw
Fax,J,Rk
[N]
Fla,H,Rk
[N]
l [mm]
When =90
Fax,H,Rk
[N]
4.5
50
C24
1251
3135
1977
4.5
50
GL24h
1303
3348
2060
4.5
60
C24
1251
3770
1977
4.5
60
GL24h
1303
4026
2060
60
C24
1488
4154
2353
60
GL24h
1551
4437
2452
80
C24
1488
4636
2353
80
GL24h
1551
4951
2452
160
GL24h
3367
13653
5324
15018
160
GL28h
3498
14508
5530
15959
180
GL24h
3367
15336
5324
16870
180
GL28h
3498
16297
5530
17927
180
GL24h
3367
15336
5324
16870
120
GL24h
3367
7089
5324
7798
180
GL28h
3498
16297
5530
17927
120
GL28h
3498
7533
5530
8286
Page 12
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Width w
[mm]
Height h
[mm]
[mm]
Joist
Header
Material
F1,Rk
[kN]
F2,Rk
[kN]
F3,Rk
[kN]
F4,Rk
[kN]
l [mm]
n90,J
n45,J
n90,H
n45,H
8045
25
45
4.5
50
C24
2,82
2,77
2,50
8075
25
75
4.5
50
C24
2,82
5,93
0,59
5,00
8160
45
60
60
C24
12,0
8,93
0,89
10,4
8211
55
110
11
60
C24
22,0
22,0
2,20
20,8
8215
55
150
10
13
60
C24
30,0
29,4
2,94
26,8
8315
75
150
10
15
60
C24
30,0
33,0
3,30
28,3
8320
75
200
12
10
19
60
C24
40,0
36,7
3,67
32,7
8420
120
200
160
GL24h
37,4
48,3
4,83
23,6
8425
120
250
160
GL24h
37,4
72,4
7,24
30,3
8430
120
300
160
GL24h
37,4
96,5
9,65
37,0
8435
120
350
10
10
160
GL24h
37,4
120,7
12,1
43,8
8440
120
400
12
12
160
GL24h
37,4
144,8
14,5
50,5
8445
120
450
14
14
160
GL24h
37,4
168,9
16,9
57,2
8450
120
500
16
16
160
GL24h
37,4
193,1
19,3
64,0
8455
120
550
18
18
160
GL24h
37,4
217,2
21,7
70,7
8460
120
600
20
20
160
GL24h
37,4
241,3
24,1
77,4
Pfostentrger Stecksystem
galvanisch verzinkt zinip beschichtet
Wichtige Informationen:
tem acesti omnis adis re pratior atus. Ga. TaepelXerferorum
HVP Nr.
Width w
[mm]
Height h
[mm]
[mm]
Joist
Header
l [mm]
n90,J
n45,J
n90,H
n45,H
8045
25
45
4.5
50
GL24h
3,01
2,96
2,61
8075
25
75
4.5
50
GL24h
3,01
6,18
0,62
5,21
8160
45
60
60
GL24h
12,0
9,30
0,93
10,9
8211
55
110
11
60
GL24h
22,0
23,5
2,35
21,7
8215
55
150
10
13
60
GL24h
30,0
31,4
3,14
27,9
8315
75
150
10
15
60
GL24h
30,0
35,3
3,53
29,5
8320
75
200
12
10
19
60
GL24h
40,0
39,2
3,92
34,1
8420
120
200
160
GL28h
39,8
51,3
5,13
24,5
8425
120
250
160
GL28h
39,8
76,9
7,69
31,5
8430
120
300
160
GL28h
39,8
102,6
10,3
38,5
8435
120
350
10
10
160
GL28h
39,8
128,2
12,8
45,5
8440
120
400
12
12
160
GL28h
39,8
153,9
15,4
52,5
8445
120
450
14
14
160
GL28h
39,8
179,5
18,0
59,5
8450
120
500
8
3
16
4
*In Einschubrichtung mit Schrauben 8 x 180 mm Vollgewinde, Holz GL 28h
8455
120
550
8
3
18
4
**Andere Holzklassen oder Schraubenlngen knnen Sie aus unserem Statik-Buch,
das Sie unter
8460 info@pitzl.de
120 anfordern
600 knnen,8entnehmen.3
20
4
16
160
GL28h
39,8
205,2
20,5
66,5
18
160
GL28h
39,8
230,8
23,1
73,5
20
160
GL28h
39,8
256,5
25,6
80,5
Page 13
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Width w
[mm]
Height h
[mm]
[mm]
Joist
Header
n90,J
n45,J
n90,H
n45,H
Material
F1,Rk
[kN]
F2,Rk
[kN]
F3,Rk
[kN]
F4,Rk
[kN]
l [mm]
8045
25
45
4.5
60
C24
3,43
3,33
2,50
8075
25
75
4.5
60
C24
3,43
5,93
0,59
5,00
8160
45
60
80
C24
12,0
8,93
0,89
10,4
8211
55
110
11
80
C24
22,0
24,6
2,46
20,8
8215
55
150
10
13
80
C24
30,0
30,6
3,06
26,8
8315
75
150
10
15
80
C24
30,0
35,3
3,53
28,3
8320
75
200
12
10
19
80
C24
40,0
41,0
4,10
32,7
8420
120
200
180
GL24h
42,1
54,2
5,42
23,6
8425
120
250
180
GL24h
42,1
81,3
8,13
30,3
8430
120
300
180
GL24h
42,1
108,4
10,8
37,0
8435
120
350
10
10
180
GL24h
42,1
135,6
13,6
43,8
8440
120
400
12
12
180
GL24h
42,1
162,7
16,3
50,5
8445
120
450
14
14
180
GL24h
42,1
189,8
19,0
57,2
8450
120
500
16
16
180
GL24h
42,1
216,9
21,7
64,0
8455
120
550
18
18
180
GL24h
42,1
244,0
24,4
70,7
8460
120
600
20
20
180
GL24h
42,1
271,1
27,1
77,4
NB: 70mm Spax screws with ef= 61mm (such as 80mm Spax screws) can be as well used without diminution of the load-carrying capacity.
Tabelle 6: Kombination 4 ( 4.5 x 60 / GL24h; 5 x 80 / GL24h ; 8 x 180 / GL28h)
HVP No.
Width w
[mm]
Height h
[mm]
Material
F1,Rk
[kN]
F2,Rk
[kN]
F3,Rk
[kN]
F4,Rk
[kN]
n90,J
n45,J
n90,H
n45,H
8045
25
45
4.5
60
GL24h
3,66
3,56
2,61
8075
25
75
4.5
60
GL24h
3,66
6,18
0,62
5,21
8160
45
60
80
GL24h
12,0
9,30
0,93
10,9
8211
55
110
11
80
GL24h
22,0
26,3
2,63
21,7
8215
55
150
10
13
80
GL24h
30,0
31,9
3,19
27,9
8315
75
150
10
15
80
GL24h
30,0
36,8
3,68
29,5
8320
75
200
12
10
19
80
GL24h
40,0
43,8
4,38
34,1
8420
120
200
180
GL28h
44,7
57,6
5,76
24,5
8425
120
250
180
GL28h
44,7
86,4
8,64
31,5
8430
120
300
180
GL28h
44,7
115,2
11,5
38,5
8435
120
350
10
10
180
GL28h
44,7
144,1
14,4
45,5
8440
120
400
12
12
180
GL28h
44,7
172,9
17,3
52,5
8445
120
450
14
14
180
GL28h
44,7
201,7
20,2
59,5
8450
120
500
16
16
180
GL28h
44,7
230,5
23,0
66,5
8455
120
550
18
18
180
GL28h
44,7
259,3
25,9
73,5
8460
120
600
20
20
180
GL28h
44,7
288,1
28,8
80,5
[mm]
Joist
Header
l [mm]
NB: 70mm Spax screws with ef= 61mm (such as 80mm Spax screws) can be as well used without diminution of the load-carrying capacity.
Page 14
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Width w
[mm]
Height h
[mm]
[mm]
Joist
Header
n90,J
n45,J
n90,H
n45,H
Material
F1,Rk
[kN]
F2,Rk
[kN]
F3,Rk
[kN]
F4,Rk
[kN]
l [mm]
8420
120
200
180/120
GL24h
42,1
39,6
3,96
23,6
8425
120
250
180/120
GL24h
42,1
66,8
6,68
30,3
8430
120
300
180/120
GL24h
42,1
93,9
9,39
37,0
8435
120
350
10
10
180/120
GL24h
42,1
121,0
12,1
43,8
8440
120
400
12
12
180/120
GL24h
42,1
148,1
14,8
50,5
8445
120
450
14
14
180/120
GL24h
42,1
175,2
17,5
57,2
8450
120
500
16
16
180/120
GL24h
42,1
202,3
20,2
64,0
8455
120
550
18
18
180/120
GL24h
42,1
229,4
22,9
70,7
8460
120
600
20
20
180/120
GL24h
42,1
256,5
25,7
77,4
Material
F1,Rk
[kN]
F2,Rk
[kN]
F3,Rk
[kN]
F4,Rk
[kN]
Width w
[mm]
Height h
[mm]
n90,J
n45,J
n90,H
n45,H
8420
120
200
180/120
GL28h
44,7
42,1
4,21
24,5
8425
120
250
180/120
GL28h
44,7
70,9
7,09
31,5
180/120
GL28h
44,7
99,7
10,0
38,5
[mm]
Joist
Pfostentrger
Stecksystem
8430
120
300
8
3
galvanisch verzinkt zinip beschichtet
Header
l [mm]
8435
120
350
10
10
180/120
GL28h
44,7
128,6
12,9
45,5
8440
120
400
12
12
180/120
GL28h
44,7
157,4
15,7
52,5
8445
120
450
14
14
180/120
Wichtige
Informationen:
GL28h
44,7
186,2
18,6
59,5
8450
120
500
16
16
180/120
tem acesti44,7
omnis adis re pratior
GL28h
215,0atus. Ga. TaepelXerferorum
21,5
66,5
8455
120
550
18
18
180/120
reiciis as desequiatem
rem243,8
quae. Nem. Namus
ut
GL28h
44,7
24,4a non rectem
73,5
8460
120
600
20
20
180/120
sapedipsam
aspedita nonseca
eperiossit aut
ex etur sita 80,5
GL28h
44,7
272,6
27,3
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
6. Timber dimensions
6.1. Minimal timber dimensions and distances to the edges
Joist horizontally and vertically perpendicular to header:
In the following the minimal timber dimensions and distances to the edges are given for a connection with Spax screws of different
lengths where the joist is horizontally and vertically perpendicular to the header.
The minimal timber dimensions and distances to the edges are valid for the HVP connectors 8045 to 8320 for a loading in the direction
of insertion (F2).
For the HVP connectors high loads (8420 to 8460) they are valid for the loadings: in the direction of insertion (F2) and perpendicular to
connector plane (F1).
For other loadings and connection geometries the indications of the screws manufacturer and of the page 23 must be respected.
Page 16
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Screws length:
50 mm ( 4.5 mm)
60 mm ( 5.0 mm)
Art. No.
ConnectorStecksystem
Header beam (mm)
Pfostentrger
8045
Joist (mm)
Minimal distance to
the edges
Width
(mm)
Height
(mm)
H
Width
H
Height
Lateral
25
45
60
60
42
Minimal timber
dimensions
Up:
A
Down:
B
J
Width
J
Height
11
50
80
Minimal total
timber height:
E (mm)
Minimal timber
dimensions
Lateral
Up:
Down:
C
D
Wichtige
Informationen:
10
30
80
8075
25
75
60
90
42
10
50
110
8160
45
60
60
100
55
30
70
90
8211
55
110
60
140
55
26
100*
150
8215
55
150
60
180
55
27
100*
190
20*
10
25
190
8315
75
150
60
180
55
26
120*
180
20*
10
20
190
8320
75
200
60
230
55
27
120*
230
20*
10
15
240
* For a loading in the direction of insertion (F2) with e2<elim the minimal lateral distance to the edges (and also the timber width) can be reduce to the following value: 10 mm
Art. No.
Connector
Column (mm)
Minimal timber
dimensions
Minimal distance to
the edges
Width
(mm)
Height
(mm)
C
Width
C
Height
Lateral
Up:
A
Down:
B
8045
25
45
60
30
50
8075
25
75
60
30
50
8160
45
60
60
70
10
50
8211
55
110
60
80
10
50
8215
55
150
60
80
10
50
*In Einschubrichtung mit Schrauben 8 x 180 mm Vollgewinde, Holz GL 28h
8315
75oder Schraubenlngen
150
60knnen Sie100
10Statik-Buch,
50
**Andere
Holzklassen
aus unserem
das Sie unter
anfordern
8320 info@pitzl.de
75
200 knnen,
60entnehmen.
100
10
50
Page 17
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Screws length:
Art. No.
Connector
60 mm ( 4.5 mm)
80 mm ( 5.0 mm)
Joist (mm)
Minimal timber
dimensions
Minimal distance to
the edges
Minimal total
timber height:
E (mm)
Minimal timber
dimensions
Width
(mm)
Height
(mm)
H
Width
H
Height
Lateral
Up:
A
Down:
B
J
Width
J
Height
Lateral
Up:
C
Down:
D
8045
25
45
70
60
42
11
50
90
10
40
90
8075
25
75
70
90
42
10
50
120
10
40
120
8160
45
60
80
100
55
30
70
90
10
25
100
8211
55
110
80
140
55
26
100*
160
20*
10
40
160
8215
55
150
80
180
55
27
100*
200
20*
10
40
200
8315
75
150
80
180
55
26
120*
200
20*
10
35
200
8320
75
200
80
230
55
27
120*
240
20*
10
25
240
* For a loading in the direction of insertion (F2) with e2<elim the minimal lateral distance to the edges (and also the timber width) can be reduce to the following value: 10 mm
Art. No.
Connector
Column (mm)
Minimal timber
dimensions
Minimal distance to
the edges
Width
(mm)
Height
(mm)
C
Width
C
Height
Lateral
Up:
A
Down:
B
8045
25
45
70
30
50
8075
25
75
70
30
50
8160
45
60
70
70
10
50
8211
55
110
70
80
10
50
8215
55
150
70
80
10
50
8315
75
150
70
100
10
50
8320
75
200
70
100
10
50
Page 18
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
HVP-Verbinder
Design Manual
connectors
Screws length :
Art. No.
160mm ( 8 mm)
Connector
(mm)
(mm)
Width
Height
8420
120
200
160*
270
8425
120
250
160*
320
Minimal timber
dimensions
Minimal distance to
the edges
Pfostentrger
Stecksystem
Lateral
H
H
Height
Width
galvanisch verzinkt zinip beschichtet
Joist (mm)
Minimal total
timber height:
E (mm)
Minimal timber
dimensions
Up:
A
Down:
B
J
Width
J
Height
Lateral
Up:
C
Down:
D
30
60
120
270
20
50
310
30
61
120
320
20
50
370
Wichtige
0
20 Informationen:
45
410
8430
120
300
160*
380
30
65
120
370
8435
120
350
160*
430
30
70
120
420
8440
120
400
160*
480
30
70
120
460
8445
120
450
160*
530
30
71
120
510
8450
120
500
160*
590
30
75
120
550
20
30
610
8455
120
550
160*
640
30
80
120
600
20
25
660
8460
120
600
160*
690
30
80
120
640
20
20
700
Art. No.
Connector
Column (mm)
Minimal timber
dimensions
Minimal distance to
the edges
Width
(mm)
Height
(mm)
C
Width
C
Height
Lateral
Up:
A
Down:
B
8420
120
200
160*
150
15
60
8425
120
250
160*
150
15
61
8430
120
300
160*
150
15
65
8435
120
350
160*
150
15
70
8440
120
400
160*
150
15
70
8445
120
450
160*
150
15
71
8450
120
500
160*
150
15
80
8455
120
550
160*
150
15
80
8460
120
600
160*
150
15
80
* The screws perpendicular to the connector plane (and also the header
width) can be reduce to the following value: 120mm
Page 19
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Art. No.
Connector
Joist (mm)
Minimal timber
dimensions
Minimal distance to
the edges
Minimal timber
dimensions
Minimal timber
dimensions
Minimal total
timber height:
E (mm)
Width
(mm)
Height
(mm)
H
Width
H
Height
Lateral
Up:
A
Down:
B
J
Width
J
Height
Lateral
Up:
C
Down:
D
8420
120
200
180*
290
30
75
120
280
20
60
340
8425
120
250
180*
340
30
75
120
330
20
60
390
8430
120
300
180*
390
30
80
120
380
20
55
440
8435
120
350
180*
440
30
80
120
430
20
55
490
8440
120
400
180*
500
30
85
120
470
20
50
540
8445
120
450
180*
550
30
85
120
520
20
45
580
8450
120
500
180*
600
30
90
120
560
20
40
630
8455
120
550
180*
650
30
90
120
610
20
35
680
8460
120
600
180*
710
30
95
120
650
20
30
730
Art. No.
Connector
Column (mm)
Minimal timber
dimensions
Minimal distance to
the edges
Width
(mm)
Height
(mm)
C
Width
C
Height
Lateral
Up:
A
Down:
B
8420
120
200
180*
150
15
75
8425
120
250
180*
150
15
75
8430
120
300
180*
150
15
80
8435
120
350
180*
150
15
80
8440
120
400
180*
150
15
85
8445
120
450
180*
150
15
85
8450
120
500
180*
150
15
90
8455
120
550
180*
150
15
90
8460
120
600
180*
150
15
95
* The screws perpendicular to the connector plane (and also the header
width) can be reduce to the following value : 120mm
Page 20
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
HVP-Verbinder
Design Manual
connectors
Screws length:
180 mm + 2x120 mm ( 8 mm)
in the header (upper part) and in the joist (lower part)
Art. No.
Connector
Minimal distance to
the edges
Pfostentrger
Stecksystem
Width
Height
H
H
Lateral
(mm)
(mm)
Width
galvanisch verzinkt
zinip
beschichtet
Joist (mm)
Height
Minimal timber
dimensions
Minimal timber
dimensions
Minimal total
timber height:
E (mm)
Up:
A
Down:
B
J
Width
J
Height
Lateral
Up:
C
Down:
D
20
20
260
20
20
310
8420
120
200
180*
240
30
31
140
240
8425
120
250
180*
300
30
35
140
290
Wichtige
0
20 Informationen:
15
360
8430
120
300
180*
350
30
40
140
340
8435
120
350
180*
400
30
40
140
390
8440
120
400
180*
450
30
41
140
430
8445
120
450
180*
510
30
45
140
480
8450
120
500
180*
560
30
50
140
520
20
560
8455
120
550
180*
610
30
50
140
570
20
610
8460
120
600
180*
660
30
51
140
620
20
660
Art. No.
Connector
Column (mm)
Minimal timber
dimensions
Minimal distance to
the edges
Width
(mm)
Height
(mm)
C
Width
C
Height
Lateral
Up:
A
Down:
B
8420
120
200
180*
150
15
31
8425
120
250
180*
150
15
35
8430
120
300
180*
150
15
40
8435
120
350
180*
150
15
40
8440
120
400
180*
150
15
41
8445
120
450
180*
150
15
45
8450
120
500
180*
150
15
50
8455
120
550
180*
150
15
50
8460
120
600
180*
150
15
51
* The screws perpendicular to the connector plane (and also the header
width) can be reduce to the following value : 120mm
Page 21
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Elevation
Top view
25 < 155
or 0 or 180
35 < 145
or 0 or 180
C
Page 22
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
HVP-Verbinder
Design Manual
connectors
Pfostentrger Stecksystem
galvanisch verzinkt zinip beschichtet
6.2. Splitting capacity
2>> * ?
;
&
!"<"=76
The design of the connections
@-A shall be in accordance with Eurocode
and:
F7
& 2BCD * E
42 9 GGH :
I"$%
& >"2 *
according to
EN 1995-1-1:2010-12
Wichtige Informationen:
tem acestithe
omnis
adis re pratior plate
atus. Ga.and
TaepelXerferorum
he = hv + distance between
connector
the lower edge
In joist:
!"$%
Page 23
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
60 mm
HVP No.
Header
Joist
Header
Joist
8045
35
47
35
51
8075
65
79
65
83
70 mm
80 mm
HVP No.
Header
Joist
Header
Joist
Header
Joist
8160
50
50
50
50
50
50
8211
99
103
99
106
99
110
8215
137
142
137
145
137
149
8315
139
139
139
142
139
146
8320
188
181
188
184
188
188
Page 24
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
HVP-Verbinder
Design Manual
connectors
Pfostentrger Stecksystem
HVP connectors 8420 to 8460
galvanisch verzinkt zinip beschichtet
Value of hv in mm:
Wichtige Informationen:
180 mm
HVP No.
Header
Joist
Header
Joist
8420
192
179
199
187
8425
244
229
252
237
230
215
8430
297
274
304
282
283
260
8435
349
324
357
332
335
310
8440
402
369
409
377
388
355
8445
454
414
462
422
440
400
8450
507
459
514
467
493
445
8455
559
504
567
512
545
490
8460
612
549
619
557
598
535
Page 25
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
7. Connections to concrete
The load-carrying capacity of the concrete part (anchors and concrete) and the distance between the anchors and the edges must be calculated according to the corresponding current standards.
Fasteners of the concrete part per HVP connector:
HVP 8211B to 8320B:
6 x internal threaded anchors with M12 (or M16 according to static requirement),for example Fischer RG 18 x 125 M 12 I
6 x screws with countersunk head M12 (or M16 according to static requirement),steel quality 8.8 (inclusive in the delivery content)
The header-plates of HVP 8445B to 8460B comprise injection drilled holes in order to fill the gap between the screws and the connector-plate
and thus ensure an equal and simultaneous loading transmission of all screws and screw anchors.
Application example
NB:
HVP 8425B, 8435B, 8445B, 8450B, 8455B und 8460B are no carry articles.
Construction:
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Timber:
Fasteners:
Wood screws with countersunk head 10 x min.120mm (Thread length > 100 mm)
according to EN 14592 or with ETA; Threaded rod
Steel quality of
the connectors:
Metal Fasteners
Post [mm]
Purlin [mm]
Type
Dimension
Art.-No.
Screws
Threaded rod
min b/h
min b/h
8710
M10
8710
4x F 10x120mm
M10 4.8
+ washer 58 mm
120/120
120/90
8712
M12
8712
4x F 10x120mm
M12 4.8
+ washer 58 mm
120/120
120/90
8716
M16
8716
4x F 10x120mm
M16 4.8
+ washer 68 mm
120/120
120/90
Metalverzinkt
fasteners:
galvanisch
zinip beschichtet
- 4 full-thread wood screws with countersunk head 10 x min.120mm (thread length: min.100mm)
-Threaded rod: M10,M12 or M16 according to post-purlin connector
Wichtige Informationen:
Combined forces:
tem acesti omnis adis re pratior atus. Ga. TaepelXerferorum
If a vertical force F (compression or tension) and horizontal forces H act at the same time,the following
shall
be fulfi
et, corrovit inequality
ventiis sunt et lam
este dentium
aslled:
aliqui to que
reiciis as desequiatem rem quae. Nem. Namus a non rectem ut
di alique solupid ellest, anducit facilla niatus quatur? Neseni
sapedipsam aspedita nonseca eperiossit aut ex etur sita
dolupta tistis et aut ipidestior assunt, quos
Where:
value
E Design
F,d
RF,d
Design value of load-carrying capacity in the load cases F (compression) or F (tension) in N
E
Design value of stress in the load cases H1 or H2 in N
H,d
RH,d
Design value of load-carrying capacity in the load cases
H
or H in
N
1 2
of the
fasteners
in timber was calculated for screws with a thread
The load-carryingcapacity
length of 100mm.
withthe following equation:
and
with:
RFd, (Tension)
Design value of the load-carrying capacity in the load case F (Tension) for the thread length ef in kN
ef
effective thread length of the screws in mm
*In Einschubrichtung
mit Schrauben 8 x 180 mm Vollgewinde, Holz GL 28h
Rd,(Tension),steel
Design value
of the
capacity due to steel failure in kN
**Andere
Holzklassenfailure
oder Schraubenlngen
knnen
Sieload-carrying
aus unserem Statik-Buch,
das Sie unter info@pitzl.de anfordern knnen, entnehmen.
Page 27
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Application example
Type
Long 0,7
Fd (compression)
all types
Fd (tension)
all types
H1,d
(parallel to the purlin)
all types
3,4
3,9
8710
2,9
3,4
H2,d
(perpendicular to the
purlin)
Medium 0,8
Short 0,9
Instantaneous 1,1
8712
11,3
13,8
4,5
5,1
6,2
3,9
4,4
5,3
like H1,d
8716
Page 28
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Pfostentrger Stecksystem
galvanisch verzinkt zinip beschichtet
F1 (Compression)
F4/F5
Wichtige Informationen:
F2/F3
Type
Art.No.
Timber
Timber
Steel
Timber
Steel
8710
8710
To calculate according to
EC5
16,3
16,7
7,3
m(C)
m,0
To calculate according to
EC5
16,3
7,3
m(C)
16,3
7,3
7,3
m(C)
8712
8716
8712
8716
Steel
F1 (Tension)
To calculate according to
EC5
Timber
Steel
tem acesti omnis adis re
pratior atus. Ga.
TaepelXerferorum
et, corrovit
et lam este dentium
- ventiis sunt6,3
- as aliqui to que
reiciis as desequiatem rem quae. Nem. Namus a non rectem ut
di alique
solupid
ellest,
anducit
facilla
niatus
quatur?
Neseni
m(C)
sapedipsam aspedita nonseca eperiossit aut ex etur sita
dolupta
tistis
et
aut
ipidestior
assunt,
quos
7,3
-
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Date
Page 30
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Date
Pfostentrger Stecksystem
galvanisch verzinkt zinip beschichtet
Wichtige Informationen:
tem acesti omnis adis re pratior atus. Ga. TaepelXerferorum
et, corrovit ventiis sunt et lam este dentium as aliqui to que
reiciis as desequiatem rem quae. Nem. Namus a non rectem ut
di alique solupid ellest, anducit facilla niatus quatur? Neseni
sapedipsam aspedita nonseca eperiossit aut ex etur sita
dolupta tistis et aut ipidestior assunt, quos
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 8703 9346-0 or via e-mail to support@pitzl.de
Manufacturer:
Pitzl
Metallbau
GmbH & Co. KG
DIN
18 800
For more information and technical details, downloads and helpful video tutorials: www.pitzl.de
Alternatively, our competent staff are always available for advice:
+49 (0) 8703 9346-0 or via e-mail to support@pitzl.de
All rights reserved. Reprint in part or whole only with express permission of Pitzl GmbH
Timberconnectors
Post bases
Balcony posts / fence posts
always up to date with www.pitzl.de
Modifications and errors reserved. Images are similar. Version as of 11/2013, v250/fo-DE