15 Test Equipment and Accessories / 7VP151

7VP151 Portable Test Unit (Three-Phase)


Function overview

Features (7VP151)
LSP2370-afpen.tif

The device provides 3 current and

Fig. 15/17
7VP151 portable three-phase test system for protection relays,
transducers and energy meters (Omicron CMC 156)

Description
Distance protection, overcurrent protection and differential protection equipment
as well as monitoring relays, synchronizing
devices, energy meters and measuring
transducers can be tested using the 7VP151
test unit. The current range extends
from 0 to 12.5 A, the voltage range from
0 to 125 V.
For higher currents, voltages or power requirements, the supplementary six-phase
current amplifier unit 7VP153 and threephase voltage and current amplifier
7VP155 are offered.
For single-phase applications, the single-phase test unit 7VP152 is offered.

3 voltage outputs. All outputs are continuously and independently adjustable


in amplitude, phase and frequency.
No tapping of ranges necessary
All current and voltage outputs are
protected against overload and
short-circuit as well as against transient
overvoltages
Generator and mains circuits are galvanically separated
For controlling external amplifiers
(e.g. 7VP153 current amplifier) six
control signals (0 to 5 Vrms) are accessible for the control of amplifiers even
from third party suppliers. The amplification factors can be entered to the
operating software and are automatically considered
10 binary measurement inputs are
available for recording relay contact
switchings
Generator section and grouped inputs:
1 to 4 are galvanically separated from
the inputs 5 to 10. Input switching
thresholds can be set individually
Precision measurement section for
analog signals:
Voltage input: 0 to 10 V
Current input: 0 to 20 mA
4 potential-free contacts for switching
external devices are provided
Several test units can be synchronized
with one another
Calibration without additional, external instruments can be performed in
software
The simulation of 1, 2 or 3-pole faults
can be performed

15

Siemens SIP 2003

15/19

15 Test Equipment and Accessories / 7VP151

Selection and ordering data

Description

7VP151 portable test unit (three phase)*


including carrying bag, power cable, connection cable for PC connection,
operating instructions (manual)

Order No.

7VP151-o

Test unit and software packages


CMC 156 SW package: Protection relays
for automatic test of distance relay, f, V, I relay, DMT/IDMT relay,
automatic synchronizer, transient earth-fault relay, differential protection
CMC 156 SW package: Measuring technique to test 1 and 3-phase measuring transducer, meter

1
2

CMC 156 SW package: Complete protection relaying to test


distance relay, f, V, I relay, DMT/IDMT relay automatic synchronizer, transient earth-fault relay,
differential protection measuring technique to test 1 and 3-phase measuring transducer, meter

CMC 156 SW package: for test of all protection relays,


without automatic test procedure for distance and differential relays

Basic software
CMC 156 SW package: Protection I basic software to test all protection relays,
(Quick CMC, TransPlay, Harmonic Generator, State Sequencer, Ramping)

Output voltage
0 125 V/phase
0 127.5 V, high precision for calibration

1
2

Power supply
110 240 V AC

Guarantee
2 years (standard)

A
B

Extended
Operating language
German

0
1
2
4

English
French
Spanish

Accessories

7VP153 current amplifier*


(3/6-phase) for 7VP151, 7VP158 including carrying bag, power cable
connecting cable to 7VP151, 7VP158, 6 mm banana plug
6 channels

7VP1530-0AA0

3 channels

7VP1531-0AA0

7VP155 voltage / current amplifier*


(3-phase) for 7VP151, 7VP158 including carrying bag,
power cable connecting cable to 7VP151, 7VP158

7VP1550-0AA0

Flight case CMCase


For 7VP153, 7VP155

7VP1540-0A

For 7VP151, 7VP152, 7VP158

7VP1541-0A

15

*) When buying a 7VP151, 7VP158 and 7VP153 or 7VP155 amplifier at the same time,
a discount of 15 % on the grand total is granted.

Siemens SIP 2003

15/21

You might also like