IMPACT OF GEOMETRIC SCALING ON

CENTRIFUGAL COMPRESSOR PERFORMANCE


Jay M. Koch
Principal Engineering Leader
Dresser-Rand Company
Olean, NY, USA
ABSTRACT
Compressor performance for liquefied natural gas (LNG) main refrigeration units is very important due to the
direct link between compressor efficiency and LNG production for a fixed amount of power. Dresser-Rand
recently designed a series of new stages for the LNG market that provided improved efficiency and a wider
range of operation.
Industry practice is to rig test new stages prior to application in production units. For LNG main refrigeration
applications the production compressor can be very large with impeller diameters up to 2.0m (78.74 inches).
Rig testing is often done at a reduced size instead of the production size to minimize cost and cycle time.
Test similitude is achieved for flow coefficient and tip Mach number by direct scaling of the production
compressor geometry, but the Reynolds number is often not preserved. The resulting test rig performance
does not duplicate the performance of the production unit.
The objective of this paper is to document the impact of scaling and Reynolds number on compressor
performance. The paper details rig testing completed to validate analytical design tools. Test results are
shown for a series of impellers, at conditions typical for LNG main refrigeration compressors for both the
production size and reduced size. The test results are compared with analytical predictions from
Computational Fluid Dynamics, (CFD). A discussion is offered on how CFD can be used to predict the
scaling impact, thus allowing high confidence in the performance prediction when reduced size testing is
completed.
INTRODUCTION
There are many different process cycles that can be selected to convert natural gas to liquid form. These
include Air Products AP-M (single mixed refrigerant), AP-C3MR and AP-X, ConocoPhillips Optimized
Cascade process, Shells Double Mixed Refrigerant (DMR) and Parallel Mixed Refrigerant (PMR), and the
Black and Veatch PRICO process. The optimal process for a specific project is dependent on many factors
including the feed stock composition, quantity of LNG to be produced and local ambient conditions. Each
process has different cycle efficiencies that trade off with varying levels of capital investment. A typical
refrigeration process map is shown in Figure 1. [Ed. note: All figures and Table 1 appear at the end of the
paper, beginning on page 7.]
All refrigeration cycles require compression equipment but the compression requirements for each process
vary as each cycle requires a different refrigerant gas (Propane, Ethane, Butane, Ethylene, Methane, and
Nitrogen). The resulting variation in gas properties leads to different compressor requirements but
compressor efficiency is critical to all process cycles as higher compressor efficiency has a direct impact on
improved LNG production for a fixed amount of power.
Since compressor performance has a significant impact on LNG production, it is industry practice to require
a shop test to verify the performance quoted is achieved. Standard industry guidelines (API-617 [1]) require
the test power to be within 4% of the quoted power. However, for LNG main refrigeration applications the
end user often requests the power tolerance be reduced to 2% to ensure the plant design production level is
achieved.
1

BACKGROUND
In 2007 the OEM initiated a multi-year effort to predict power within 2% while simultaneously extending the
operating range and efficiency of main refrigeration compressors. This effort required significant
improvements to the existing design process. Previous practice was to develop staging and then use one
dimensional (1D) tools to estimate the resulting performance. Two dimensional (2D) and three dimensional
(3D) or computational fluid dynamics (CFD) tools were used in the design process, but neither tool was
capable of predicting power consumption within 2%. Once a design was complete, a rig test was conducted
to validate the performance levels predicted by the 1D tool. The performance models in the 1D tool were
then empirically adjusted to match the test results. This process worked well if the stage under consideration
was within past design experience and a significant number of highly accurate rig test sets were available.
At the start of this effort a review was conducted of the entire design process (stage design, manufacturing,
and test evaluation) to identify areas for improvement. Based on the review it was determined that the
accuracy target could be achieved using previous practice if test rig accuracy was improved to 0.5% for
critical parameters (efficiency, pressure coefficient, flow coefficient). This solution path required significant
amounts of rig testing, especially to validate new designs as multiple iterations would likely be to achieve the
extended operating envelope required for the new designs.
The process evaluation included a cost tradeoff study to minimize overall program expense. This study
concluded that rig testing with a stage diameter much smaller (0.25-0.3m) than the production diameter (1.22m) would reduce the overall cost and cycle time for the test program. While testing at a reduced size had a
cost benefit, it did create an additional prediction term in the performance prediction. Performance test
similitude is achieved for a given flow coefficient, tip Mach number, and volume reduction by direct scaling of
the production compressor geometry to a smaller size using a procedure described in ASME PTC-10 [3].
Unfortunately the Reynolds number is not preserved. The resulting test rig performance would, therefore, not
duplicate the performance of the production unit. This effect is commonly encountered with the OEM
compressor, but there were concerns that existing prediction models were not capable of achieving accuracy
requirement. It was determined that the only way to achieve the accuracy goal was to convincingly validate
the impact of scaling by quantifying the effect via rig tests at different sizes.
An alternate solution proposed was to improve the accuracy of the 3D CFD tools until they could achieve the
required prediction accuracy. This solution had two notable advantages. First, accurate CFD tools would
allow the designer to determine if new designs met performance goals prior to testing thus reducing the
number of required tests. Second accurate CFD tools could be used to predict the impact due to size,
eliminating the need to test at multiple sizes. However, the necessary improvements in the CFD tools
required accurate test results at multiple sizes for calibration. The drawback to this solution was that it was
unclear how much time it would take to achieve a reliable match between the CFD and test results.
It was ultimately decided to pursue both solutions in parallel as both solutions required accurate validation
data at various sizes to calibrate the impact due to scaling. By pursuing both options, progress toward the
ultimate continued, albeit at a slow pace, while work continued on the more challenging CFD prediction
improvements.
INVESTIGATIVE STUDY
The OEM maintains multiple rigs capable of testing different size impellers. For this study builds in the large
test rig were duplicated in the smaller test rig to benchmark the performance impact due to scaling. To
eliminate all other variables from consideration, all geometry was directly scaled with the scale factor defined
by the ratio of impeller exit diameter for the two tests (i.e., dsmall_rig/dlarge_rig). The directly scaled geometry
included all rotating and stationary components (inlet, inlet guide, impeller, diffuser, return channel, incoming
sidestream and discharge volute). The direct scaling rules were also applied to secondary features including
2

vane/blade features, thickness and machine fillets. The labyrinth seals were designed to maintain the
equivalent leakage area, thus the running clearance was directly scaled.
The large test rig is a large-frame, multi-stage centrifugal compressor, this test rig has been described
previously in the literature including, Gilarranz [4] and Sorokes et al [5]. This test rig has a pressure
containing case that was designed for maximum flexibility and allows different compressor arrangements to
be easily constructed. This enables testing of a variety of flowpaths, including sidestream configurations. The
test rig has provisions to include moveable geometry in the stationary components at certain key locations
within the flowpath. The large rig is driven by a 22.4MW (30,000HP) steam turbine and speed reducing gear.
A typical machine configuration modeling a production propane compressor comprises 3-5 centrifugal stages
in a straight-through arrangement. A typical compressor arrangement and the location of the variable
geometry vanes are shown in Figure 2.
The aerodynamic flowpath can be heavily instrumented to maximize the amount of stage or components
parameters that are directly measured. Instrumentation that can be installed includes total pressure probes,
static pressure taps, dynamic pressure probes, total temperature probes, and 5-hole probes. Note that the 5hole probes measure static pressure, total pressure, and flow angle. The data from the 5-hole probes can
also be used to determine flow velocity at the probe location.
A typical schematic of the internal instrumentation layout used in each compressor stage is given in Figure 3.
The location of the instrumentation allowed measurement of the overall stage performance, as well as the
performance of each individual component in the stage. This allows the performance of the inlet guide, the
impeller, the diffuser and the return channel to be measured on an individual basis. The component data
measured during the testing was used for the validation and calibration of the 1D and 3D analytical methods
and tools used for stage design and performance prediction.
In addition to the large test rig, the OEM also has the capacity to test the same geometry in a small test rig,
which can be configured in either a single or two-stage arrangement. This particular test rig is capable of
testing impellers 0.3m to 0.5m (12-20) in size. The rig is driven by a 1.12MW (1500HP) electric motor and a
speed increasing gear, offering a wide range of operating speeds. A range of Mach numbers and Reynolds
numbers can be achieved by varying the test gas and suction pressure.
The rig is comprised of a series of stackable rings that form both the aerodynamic flow path and the rig
casing. The ring concept allows all instrumentation leads to be extracted thorough the outside diameter of
the rings, facilitating instrumentation connections to the data acquisition system. The stackable ring
construction allows greater flexibility in build configurations. It is possible to test a first stage configuration
(i.e., following a main inlet), an intermediate stage, a discharge stage (i.e., with a volute or collector) or two
stages with an intermediate sidestream. A typical schematic of the internal instrumentation layout used in
each compressor stage is given in Figure 4.
Both test vehicles are installed in a closed-circuit test loop and were run using R-134A as a test medium.
The testing was conducted in accordance with the ASME PTC-10 Code [3]. The test loop was also
instrumented in accordance to ASME PTC 10, with the intent of gathering flange to flange performance. A
schematic of the pipe loop instrumentation and measured parameters are shown in Figure 5.
The investigative study is based on several builds of the large test rig and the corresponding small test rig
builds. The selected builds were patterned after typical propane compressors using the AP-C3MR
process. The production compressor for this process typically contains 4 to 5 stages with incoming
sidestreams proceeding stages 2, 3 and 4. The impact of the flow entering through the sidestream has a
significant impact on the performance measured at the compressor flanges. The study outlined in this paper
focused on the impact of scaling and concentrated on the internal performance measured at the inlet and
3

outlet of each stage. The impact of the incoming sidestream on performance has been documented in other
papers, Koch et al [6], Fakhri et al [7], and will not be discussed is this paper.
A typical build configuration of the large test rig and corresponding small rig builds is shown in Figure 6.
While the large test rig is patterned after a production compressor with up to 5 stages, the small test rig is
limited to 2 stages. Therefore, the small rig tests break down the domain of the large rig into representative
blocks of 1 to 2 stages for testing. In the example show in Figure 6 the first stage following the main inlet is
tested as a single stage with the tested domain stopping that the exit of the return channel. The remaining
stages are preceded by an incoming sidestream. In the small rig this was modeled by testing two stages in
series with a sidestream between the two stages. Only the data from the second impeller in the small rig is
used in this configuration, thus correctly simulating all operating conditions and geometry. For the last
impeller in the compressor the discharge volute was included.
Improvement of any prediction tool requires an accurate test measurement system and known geometry for
the tested equipment. Prior to testing, the data acquisition system was calibrated to provide a test
uncertainty of 0.5% for the measured flow, pressure coefficient, and efficiency (see Gilarranz [8, 9]). This
required a review of the data acquisition hardware and the calibration of pressure, temperature, and flow
instrumentation.
Uncertainty due to geometry variation was minimized through proper selection of manufacturing methods,
controlling part tolerances and verification through very detailed inspection. All impellers tested were single
piece machined (Figure 7). All hardware was inspected, with all blade and vane rows assessed using laser
scans to identify the true surface geometry.
COMPARISON OF TEST RESULTS
While many configurations were evaluated, this paper focuses on the results of two particular stages. The
basic geometric and performance parameters for these stages are shown in Table 1. The two selected
stages have a similar design machine Mach number and flow coefficient, but have different blading designs
resulting in different performance characteristics. The Reynolds number is higher for the large test rig, due to
the larger passage widths. The existing 1D model predicted both the efficiency and the polytropic head
coefficient would increase from the small test rig to the large test rig. A small shift of the entire curve to
higher capacity was expected due to the thinner boundary layers which would allow the impeller to pass
increased flow at the same machine Mach number.
A comparison of the large rig and small rig results are shown in Figures 8 and 9. In these figures the
polytropic efficiency and pressure coefficient are plotted versus inlet flow coefficient. All values are
normalized by the design value to allow relative comparison of the results. The overall curve shape and
operating range are very similar between the large and small rig results as expected.
The results for stage 1 are shown in figure 8. At the design flow the pressure coefficient is slightly lower and
the efficiency is slightly greater than for the large rig compared to the small rig. The maximum capacity
increased and stability increased for the large rig compared with the small rig. The detailed inspection for the
stage 1 impeller indicated the impeller surfaces were within tolerance but at the upper limit and thus had
more material remaining than required resulting in approximately 0.5% smaller passage area and could
explain the reduced head at design. The results for stage 2 are shown in Figure 9. For stage 2 both the
pressure coefficient and efficiency improved for the large rig compared to the small rig. The maximum
capacity was unchanged.
The deviation between the test results and the existing 1D prediction model at the design flow rate are within
the 2% accuracy goal, but the existing model did not capture the differences in performance between the two
stages. While it is very difficult to quantify these small changes it was felt additional improvements could be
made to the existing model.
4

ANALYTICAL INVESTIGATION
As discussed previously a parallel study was initiated to improve the accuracy of CFD-based predictions.
This project began with discussions with the CFD software vendor (ANSYS-CFX) and several
turbomachinery consultants in the U.S. and Europe who regularly used the software. Critical parameters that
could be sources of variation were identified in these discussions: the computation grid, the solver options
specified for each solution, the gas properties used by the software, the methods used to post-process the
results and compare with the tested results, and the accuracy of the test geometry and results geometry.
The team then undertook a systematic study to identify the sensitivity of the each of the critical parameters
and evaluate which combination of parameters best matched all available data. This required an extensive
amount of CFD analyses to evaluate the many different combinations. The validation exercise culminated in
a standard process that is now used by the OEM CFD analysts to predict performance. The standard work
document includes criteria for grid size and quality, selection of CFD solver options, gas properties, and
methodology for comparing CFD and measured test results, (see Kowalski et al [10]).
Comparisons of the CFD predictions for the tested geometry discussed previously are shown in Figures 10
and 11. The shapes of the CFD predictions were very similar to the tested results shown in figures 8 and 9.
For the first stage the CFD predicted pressure coefficient and efficiency were greater respectively for the
large rig than the small rig. The overall compressor range was essentially unchanged. For stage 2 the
pressure coefficient and efficiency also improved. The maximum capacity for stage 2 increased a small
amount for the large rig compared with the small rig.
The tested deviation between the large rig and small rig performance at the design point is very similar to the
deviations from the CFD results. This good correlation between CFD and test was achieved without
empirical tuning which provides confidence the 3D tools can be used to estimate the impact of scaling for
new designs that fall outside the correlated range of the existing model. The slight over prediction of the
pressure coefficient and capacity for stage 2 while quite good might still be improved via additional
investigations.
CONCLUSIONS
This study demonstrated that the performance impact due to scaling can be quantified by testing the
compressor in both large and small sizes. The test results validate that while the scaling effects are relatively
small for these stages, they must be addressed to consistently achieve the desired prediction accuracy of
2% at the compressor design point. The results also indicate that one can have high confidence in the stage
performance prediction once reduced size testing is completed, thus eliminating the need for large rig
testing. Finally, the study has shown that CFD prediction has improved significantly and can now be used to
estimate the impact due to scaling when empirically correlated 1D tools are not available or outside the
calibrated range.
ACKNOWLEDGEMENTS
The author would like to thank Dresser-Rand Company for funding this overall project and for allowing the
publication of this work.
NOMENCLATURE

Q
3
N D2
Q = volumetric flow in cubic feet per minute
N = operating speed in rotations per minute (rpm)
D2 = impeller exit diameter in inches
= flow coefficient =

700.33

Machine Mach number =

U2
Ao

A0 = sonic velocity of gas in meters per second (feet per second)


U2 = impeller tip speed in meters per second (feet per second)
U 2 b2
Reynolds number =

= density in kg per cubic meter (pounds per cubic feet)


b2 = impeller tip width in meters (feet)
= viscosity in kg per meter per second( pounds per feet per second)
REFERENCES
1. American Petroleum Institute, 2009, API STD 617, Axial and Centrifugal Compressors and Expandercompressors for Petroleum, Chemical and Gas Industry Services, Seventh Edition.
2. Schultz, J. M., 1962, The Polytropic Analysis of Centrifugal Compressors, ASME Journal of
Engineering for Power, Vol. 84, pp.69-82, New York
3. ASME, 1997, PTC 10, Performance Test Code on Compressors and Exhausters, ASME Press.
4. Gilarranz, J., Actuation and Control of a Movable Geometry System for a Large Frame-Size, Multi-Stage
Centrifugal Compressor Test Rig, ASME Paper GT2007-27592, Proceedings of GT2007, ASME Turbo
Expo 2007, Montreal, Canada
5. Sorokes, J.M., Soulas, T.A., Koch, J.M., Gilarranz, J.L., 2009, Full-Scale Aerodynamic and
Rotordynamic Testing for Large Centrifugal Compressors, Turbomachinery Symposium Proceedings,
Houston, USA
6. Koch, J., Sorokes, J., Belhassan, M., 2011,Modeling and Prediction of Sidestream Inlet Pressure for
Multistage Centrifugal Compressors , Turbomachinery Symposium Proceedings, Texas A&M
7. Fakhri, S., Pacheco, J., Koch, J., 2012,Centrifugal Compressor Sidestream Sectional Performance
Prediction Methodology, Turbomachinery Symposium Proceedings, Texas A&M
8. Gilarranz, J. L., 2005, Uncertainty Analysis of a Polytropic Compression Process and Application to
Centrifugal Compressor Performance Testing, Paper GT-2005-68381, Proceedings of GT2005, ASME
Turbo Expo 2005, Reno, USA
9. Gilarranz, J. L., 2006, Uncertainty Analysis of Centrifugal Compressor Aero-Performance Test Data:
Effects of Correlated Systematic Error Paper GT-2005-68381, Proceedings of GT2006, ASME Turbo
Expo 2006, Barcelona, Spain
10. Kowalski, S., Fakhri, S., Pacheco, J., Sorokes, J., 2012, Centrifugal Stage Performance Prediction and
Validation for High Mach Number Applications, Turbomachinery Symposium Proceedings, Houston,
USA

Figure 1 -- AP- C3MR

TM

LNG Process

Figure 2 Large Test Rig

Figure 3 Typical Instrumentation for Large Test Rig

Figure 4 Small Test Rig

Speed

Compressor

Discharge
PT
TT

Inlet
TT
PT

Cooling Water
Test Gas
Composition

Pipe ID,
Orifice D

PS , TS

Test Gas Cooler


Throttle
Valve

Flowmeter (Orifice)

Figure 5 Schematic of Typical Closed Loop Test Set-up

Stage 1
Following main inlet

Stage 2 & 3
Stage 2 - Following main inlet
Stage 3 - Following sidestream

Stage 3 & 4
Stage 3 - Following main inlet
Stage 4 - Following sidestream

Figure 6 Typical Cross Section of Large Test Rig and Corresponding Small Rig Configurations
Table 1 Comparison of Key Parameters for Test Rigs

Stage #
1
2

Inlet Flow
Coefficient
0.0969
0.1072

Large Rig
Machine
Impeller Reynolds
Mach Number Diameter Number
1.131
47.335
6776301
1.139
49.501
15442890

Small Rig
Impeller Reynolds
Diameter
Number
12.385
2630000
12.952
5630000

Large Rig Impellers

Small Rig Impellers


Figure 7 Single Piece Machined Rig impellers

10

Figure 8 Test results for Large Rig vs. Small Rig Stage 1

Figure 9 Test results for Large Rig vs. Small Rig Stage 2
11

Figure 10 CFD Prediction for Large Rig vs. Small Rig Stage 1

Figure 11 CFD Prediction for Large Rig vs. Small Rig Stage 2
12