CATALOGUE
www.lennoxemeia.com
Heat recovery
Electrical heater
R410A refrigerant
Centrifugal fan
32
44
50
58
70
80
96
108
110
Airside products
118
Water cassettes
ARMONIA - COANDAIR
130
142/156
146
158
164
166
172
Telecom units
@DNOVA
Close control units
INNOV@ - INNOV@ ENERGY INVERTER
In Row close control unit for high density system
R@CKCOOLAIR
178
GC15-E_V1
LENNOX HVAC
Lennox HVAC&R EMEIA, part of Lennox
International Incorporated, is the result
of a merger (October 2012) with Lennox
EMEIA (HVAC) and Heatcraft Europe
(Refrigeration). Lennox HVAC&R EMEIA
is a leading provider of climate control
solutions for heating, air conditioning,
and refrigeration markets and has the
commitment to assist its customers in
their projects, to provide optimized and
sustainable solutions.
Lennox HVAC&R EMEIA ensures that
each employee flourishes within the
group, so as to contribute to the
success of our customers projects.
Every day we develop our reputation
by providing maximum comfort and
efficiency through our air conditioning
and refrigeration solutions.
&
2
2
GC15-E_V1
*:
HVAC&R = Heating ventilation airconditioning
and refrigeration
EMEIA = Europe Middle-Esat India Africa zone
9 800
people
3,4
Billion $ turnover in
2014.
Quoted on NYSE
Presence
on
continents
1 050
permanent people
Quality standards :
ISO 9001
Environmental standards
HVAC&R European
development center
(*)
ISO 14001
Occupational health and safety
management systems (*) :
OHSAS 18001
LENNOX HEATCRAFT UNIVERSITY : More than
700
Commercial presence in
46
3 commercial brands:
Lennox, HK Refrigeration, Friga Bohn.
countries
GC15-E_V1
3
3
Burgos factory in Spain (between Madrid and San Sebastian - ), 7000 sqm, produces
monobloc units and ductable splits, small and medium chillers and rooftops.
Longvic (close to Dijon in France - ), our 13000 sqm plant is dedicated to rooftop
assembly, with its own sheet metal facility.
Genas Plant (Lyon area, France - ), our 14000 m plant, produces medium and large
scroll chillers as also refrigeration equipments. This plant is also fully autonomous in
sheet metal manufacturing.
INNOVATION
Technologies evolve, regulations too: the LENNOX HVAC&R EMEIA teams work
to invent solutions that, day after day, improve the lives of our customers,
responding to ever changing expectations :
_ Ease of installation
_ Energy efficiency: how to provide the highest level of comfort while
minimising energy costs
_ Reduction of maintenance frequencies and costs
_ Optimization of end of life recycling
_ Common solutions between HVAC and Refrigeration
_ Green solutions able to fit the high legal expectations (including HFO and
natural refrigerants solutions responding FGaz and other environmental
directives)
We focus on the overall cost of use of our solutions, from the start to the end
of their lives.
Because of this, LENNOX HVAC&R EMEIA is responsible for a number of major
innovations.
GC15-E_V1
ARMONIA
ALLEGRA
1,3 11 kW
0,6 6,7 kW
Page 130
Page 118
ECOLEAN
Flexair
20 200 kW
Page 80
85 220 kW
Page 37
AIRCOOLAIR
20 100 kW
19 134 kW
Page 64
6
6
COMPACTAIR
GC15-E_V1
Page 70
Food retail
SRC
MOPSH*
50 220 kW
22 385 kW
Page 108
Unit heater
AXIL
Compressor rack
ECO2GEN*
12 105 kW
18 80 kW
Page 158
Flexair
85 220 kW
Page 37
Cubic evaporator
3C*
1 35 kW
MXW
50 1660 kW
Page 114
0 157 kW
Page 22
* : For more information on this product, please consult the HEATCRAFT product catalogue
Non contractual photos
GC15-E_V1
7
7
Shopping malls
AQUALEAN
2 20 kW
Page 58
BALTIC
BALTIC WSHP
24 85 kW
46 92 kW
Page 32
Page 44
0 157 kW
Page 22
MWC
ADALINK
180 720 kW
Page 178
Page 102
8
8
GC15-E_V1
Restaurants
Cubic evaporator
3C*
1 35 kW
BALTIC
24 85 kW
Page 32
Condensing unit
VANGUARD*
0,5 12,2 kW
* : For more information on this product, please consult the HEATCRAFT product catalogue
Non contractual photos
GC15-E_V1
9
9
Office Buildings
Chilled water cassette
ARMONIA
NEOSYS
1,3 11 kW
200 1000 kW
Page 130
Page 90
AQUA4
ALLEGRA
50 320 kW
0,6 6,7 kW
Page 86
Page 118
CLEANAIR LX
1000 10000 m3/h
Page 156
Dry cooler
FC/FI NEOSTAR
20 1200 kW
Page 110
LennoxHydroControl
Page 181
R@CKCOOLAIR
3 74 kW
Page 172
10
10
GC15-E_V1
COANDAIR
MINIAIR
0,8 5,1 kW
2 44 kW
Page 136
Page 142
Hotel
Air cooled chiller/Heat pump
ECOLEAN
CLEANAIR LX
20 200 kW
Page 80
Page 156
AQUA4
VANGUARD
50 320 kW
0,5 12,2 kW
Page 86
COANDAIR
0,8 5,1 kW
Page 136
Cubic evaporator
3C*
1 35 kW
BALTIC
MINIAIR
ALLEGRA
24 85 kW
2 44 kW
0,6 6,7 kW
Page 32
Page 142
Page 118
* : For more information on this product, please consult the HEATCRAFT product catalogue
Non contractual photos
GC15-E_V1
11
11
0 157 kW
Page 22
NK*
6 130 kW
BALTIC
24 85 kW
Page 32
GTA*
11 82 kW
Compressor rack
MXW
MOVSH*
50 1660 kW
70 700 kW
Page 114
* : For more information on this product, please consult the HEATCRAFT product catalogue
12
12
GC15-E_V1
Industry
Air cooled chiller/Heat pump
ECOLEAN
20 200 kW
Page 80
COANDAIR
NEOSYS
0,8 5,1 kW
200 1000 kW
Page 136
Page 90
ARMONIA
1,3 11 kW
Page 130
Dry cooler
FC/FI NEOSTAR
20 1200 kW
Page 110
0 157 kW
Page 22
GC15-E_V1
13
13
Data Centers
INNOV@
6 240 kW
Page 166
14
14
GC15-E_V1
NEOSYS
ALLEGRA
200 1000 kW
0,6 6,7 kW
Page 90
Page 118
Training Center
UNIVERSITY
To enhance your
refrigeration and air
conditioning skills, in an
ever changing technological and regulatory environment
To increase your competitive advantage in an ever
changing technological and regulatory environment,
for refrigeration and air conditioning, LENNOX offers
you a European training center to :
improve your operational knowledge
optimise your professional activities
become more competitive.
The courses
The equipments
Alcatel
Auchan
Axima
Carrefour
Cegelec
City Facilities
Cofely
Dalkia
Elyo Suez
Ikea
Johnson Control
Jtek
Mc Donalds
Veolia
and more ...
GC15-E_V1
15
0 157 kW
0 27000 m3/h
eNeRGy is the new standard for
packaged air treatment solutions allowing combination
of a fixed air treatment section with different
thermodynamic platforms, in order to propose different
alternatives of cooling or heating capacities, while
keeping the same indoor air quality standards.
eNeRGy is a
packaged plug and
play solution, using the latest technology. This range is
particularly flexible to be adjusted as close as possible
to the customer's needs.
More information about eNeRGy range
on
Flexair
page 22
85 140 kW
FLEXAIR is the new generation of rooftops that
With an improved
and lighter
structure, both
in the indoor air
treatment section
and in the condensing section, FLEXAIR stands out
by its flexibility (different airflow configurations) and the
possibility of installation on any type of structure.
More information about FLEXAIR range
on
SRC
page 37
50 220 kW
The SRC allows recoverery of thermal energy rejected by the
commercial refrigeration to heat the sales area, thus achieving
significant energy savings over the annual heating consumption.
More information about SRC range
on
16
16
GC15-E_V1
page 108
page 90
AQUA4
50 320 kW
AQUA4 is a unique concept to reduce our
page 86
LennoxCloud
LennoxHydroControl
GC15-E_V1
17
INVESTMENT IN LENNOX
EQUIPMENT
Commissioning
Training
Remote supervision
and monitoring
Contract for
manufacturer visit
COMMISSIONING
Commissioning of your equipment by LENNOX
technicians.
TRAINING
LENNOX has an approved international training centre
to meet the needs of HVAC professionals.
SUPERVISION
LENNOX offers supervision solutions, allowing you to
manage all your technical facilities in addition to the air
conditioning/heating, e.g. ventilation, electricity, alarms,
etc.
REMOTE MONITORING
LENNOX also offers remote supervision of your
equipment:
Remote monitoring of the operation of your units.
Direct malfunction warning for better responsiveness.
In-depth analysis of recorded data to guide you in your
operation.
18
18
GC15-E_V1
ts Spare parts
Technical
assistance
Manufacturer's
audit
Retrofit
Drop in
Eco recycling
WEEE
RETROFIT / DROP IN
Regulation:
Upgrading of your old equipment control.
Optimisation of energy and comfort.
Fluids:
According to the F-gas Regulation, topping up any
equipment with HCFC has been prohibited since
1 January 2015. LENNOX helps you examine the
different solutions for replacement with an authorised
fluid.
TECHNICAL ASSISTANCE
LENNOX offers customised technical assistance services
MANUFACTURER'S AUDIT
Full technical analysis and operating reports for all
your equipment.
Precise diagnosis by LENNOX following the reports.
Recommendations, LENNOX action plan to help you
compile your investment budgets.
equipment.
GC15-E_V1
19
19
High efficiency
packaged air
treatment unit
20
GC15-E_V1
0 157 kW
0 27000 m3/h
22
GC15-E_V1
21
0 157 kW
0 27000 m3/h
eRecovery
Energy recovery on food refrigeration
systems
e-CLIMATIC Advanced
controller
Intelligent controller to
improve efficiency and help
set up and service
Filtration options
Several levels of filtration :
G4 / G4+F7 / G4+F7+F9
Innovative casing
Minimal air pressure losses
22
GC15-E_V1
Modularity concept
Nowadays, buildings are taking advantage of the best construction techniques, and the different improvements in isolation
and lightning technologies contribute to decrease the cooling
or heating demands.
eNeRGy range is fully adapted to this new trend and can
offer different combinations of thermodynamic refrigerant
circuits with the same indoor airflow, giving different cooling
or heating capacities
Architectural features
EC fan technology
Filters
GC15-E_V1
23
Easy installation
In the new eNeRGy range, the condensing section and the air
treatment section are combined together. This configuration
makes the mounting easier and do not require extra casing
for installing the extraction fans. The roofcurb will be proposed
only if the installation requires this structure.
To make the installation of eNeRGy unit easier, the following
options are available :
Airflow configurations : Vertical supply and return as
standard, horizontal configurations of air supply as an
option.
Adjustable roofcurb: This adjustable roofcurb can be
installed on a sloped roof with vertical supply and return
airflow configuration.
24
GC15-E_V1
Safety
M0 fire proof insulation: eNeRGy units feature M0 rock or
glass wool insulation as standard.
The insulation will not burn and will not generate smoke in
case of fire.
Smoke detector: The optical head of the smoke detector
can detect any type of smoke. When this occurs the unit
will stop operating, the return air damper will close fully
and the fresh air damper will open completely.
Fire-stat: This safety thermostat provides fire protection
by switching off the unit and closing the fresh air damper.
Three phase relay detector : This device offers the
guarantee of the correct phase connection, together with
an overvoltage and under voltage protection.
Refrigerant leak detection: this option enables the
customer to check if the refrigerant charge has variations
during the life cycle of the unit, through sensors placed in
the refrigerant pipes, to easier maintenance operations
and prevent failures.
Control features
CLIMATIC general description
This last generation of controls is designed to provide best energy
efficiency throughout the unit life cycle while ensuring reliable and
consistent operation.
eCLIMATIC integrates innovative PID control that will guaranty
better temperature accuracy, while saving energy. It also ensures
compressor running time optimisation.
It manages security algorithms and displays fault signals. It has
extended scheduling capability with the possibility to adjust many
set points over the various time zones.
It is user friendly through a wide choice of displays and
communication interfaces while providing flexibility, with the ability
to control multiple units on a single job site.
CLIMATIC standard features
Step of heating priorities: Allows the user to choose which
heating element should come first.
Automatic summer winter change: eCLIMATIC integrates
an automatic time switch from winter to summer time.
Noise reduction feature: The control will reduce the
capacity of the unit during unoccupied zone to limit outdoor
noise at night when capacity needed is lower and when
noise matters more.
Staged start feature: If there is a power shortage, units
will not restart at the same time.
Morning anticipation and dynamic set point: The unit
can be programmed to anticipate the morning cooling or
heating needs depending on the outdoor temperature.
Dynamic set point can be used in summer to offset the
ambient temperature set point according to the outdoor
temperature.
Dynamic defrost: It is a standard feature of all Lennox
heat pumps. It limits the number and the duration of the
defrost cycles in winter to maximize COP.
GC15-E_V1
25
eNeRGy
General data
eNeRGy
E14
E16
E16
E19
E22
E27
075
085
105
124
140
160
71,0
82,1
98,0
114,2
131,8
154,6
22,9
26,8
32,6
37,7
43,7
51,3
3,10
3,07
3,01
3,03
3,01
3,01
69,1
83,7
106,8
119,4
140,7
158,5
20,3
24,5
33,3
35,0
43,8
49,3
3,40
3,41
3,21
3,41
3,21
3,22
4/2
4/2
4/2
4/2
2/2
4/2
37
37
28
36
30
40
Cooling mode
Net cooling capacity (1)
Net absorbed power
kW
(1)
Heating mode
Net heating capacity (1)
kW
(2)
Refrigerant circuit
Number of compressors/Number of circuits
kg
(3)
48
Ventilation
Nominal airflow rate
Minimum airflow rate
m3/h
13500
15500
15500
18900
21600
27000
9500
10500
10500
13000
15000
18500
24000
24000
24000
24000
24000
32000
Auxiliary heating
Gas heat capacity
S-V/S-Ho (4)
H-V/H-Ho (4)
S/M/H (4)
S
H
kW
kW
kW
82/82
100/100
100/130
200/200
36/90/108
54/108/144
69,6
74,5
81,9
81,9
117,9
123,9
122,2
132,0
146,9
146,9
191,6
202,5
80,8
76,3
78,3
81,4
81,4
81,6
81,2
77,0
78,8
81,8
82,5
82,1
77,0
80,6
80,6
85,5
91,9
86,4
dB(A)
(3) The cooling and heating operating limits are given for steady state running condition
with noted temperature condition
(4) S = Standard heat
M = Medium heat
H = High heat
V = Vertical supply
Ho = Horizontal supply
eNeRGy is part of RT Eurovent Certification Program.
Weights - kg
E14
E16
E16
E19
E22
E27
075
085
105
124
140
160
1582
1592
1625
1648
2030
2170
1600
1609
1642
1664
2052
2191
1895
1905
1938
1961
2342
2533
1912
1922
1955
1977
2365
2554
2459
2469
2502
2525
2891
3081
2476
2486
2519
2541
2913
3102
eNeRGy
Basic unit
26
GC15-E_V1
Dimensions
E14-E19
With condensing section and
heat recovery wheel option
9
431
22
72
1869
2275
2275
5
183
227
2
4691*
* including electrical panel
612
1
58
E22-E27
Without condensing section and
with heat recovery wheel or thermodynamic
heat recovery option option
2275
2275
6
243
9
431
22
72
227
2
619
4691*
* including electrical panel
612
E14
075
eNeRGy
E16
085
E16
105
E19
124
E22
140
E27
160
2101
2101
795
795/
574
C
Adjustable / Non adjustable roofcurb
mm
GC15-E_V1
27
Option
EAC/EAH
Standard equipment
eNeRGy
Energy recovery
Refrigerant
Leak detection
Electronic pressure sensors
Multiscroll
Tandem
Compressors
Silent start
Refrigerant lock-out safety
Compressor noise jacket
Expansion valves
Supply fans
Condenser fans
Economiser
Casing
Insulation
50 mm double skin
Double-skin (all parts in contact with airflow)
Air filter
EU4
Refillable EU4
EU4 + F7
LenGuard anti-corrosion protection on evaporator coil
Anti-corrosion protection
LenGuard anti-corrosion protection on condenser coil
Downflow supply
Air flow configuration
Horizontal supply
Downflow return
Horizontal return
Gravity exhaust damper (vertical exhaust)
Exhaust
28
GC15-E_V1
Option
Roofcurbs
Packing
EAC/EAH
Standard equipment
eNeRGy
GC15-E_V1
29
Rooftop packaged
units
30
GC15-E_V1
32
37
44
50
52
GC15-E_V1
31
BALTIC
24 85 kW
Main applications
Large and light commercial buildings (retail, airports
Cinemas, theatres
Industrial buildings and logistic centers
General description
Rooftop solution is the most cost effective package solution
for high efficiency comfort air conditioning of single volume
buildings.
First class efficiency system thanks to multiscroll
compressor technology associated with chlorine free
R410A refrigerant. The rooftop unit product line is
Lennox most innovative equipment for commercial
applications.
eDrive variable speed direct transmission ventilation
system to save even more energy on BALTIC and
FLEXAIR ranges.
Advanced CLIMATIC controller, designed to improve
energy efficiency and reliability. This controller
integrates master slave capability and a wide choice of
communication interfaces.
Cost effective package solution for fast and easy
installation.
Low weight construction for easy lifting in all site
configurations.
Many standard airflow configurations and wide range of
adjustable roof curbs to suit all type of building designs.
Multiple auxiliary heating options available, with intelligent
control to allow the selection of the most efficient way
to generate heating based on the outside temperature
and/or energy costs.
Fresh air control and free cooling/heating management
for healthy and comfortable environments.
Heat recovery solutions on exhaust air or to recover
calories generated by refrigeration equipments
The units are available with the following versions:
> Cooling only
> Heat pump
> Cooling only with gas burner standard heat or high
heat
> Multiple fuels units combine heat pump with gas fired
heating
32
GC15-E_V1
Main components
R410A scroll compressors
EN 60204-1 electrical cabinet with circuit breaker
Voltage 400V/3Ph/50Hz
CLIMATIC controller
Full text fault display and history.
Many settings and readings available for customization
and diagnostic.
eDrive:
Variable speed direct drive fan with eFlow
airflow measurement
compressor
technology for best load
performance year round
R410A refrigerant for best
efficiency
Electronic expansion valves for
optimum control in all conditions
Optimised heat exchanger
surface area to boost system
energy
4,5
MultiScroll + eDriveTM
4,0
Multi-Scroll
3,5
Inverter Scroll
3,0
Single Scroll
2,5
2,0
1,5
10
20
30
40
50
60
70
80
90 100
GC15-E_V1
33
BALTIC
General data
BALTIC
024
030
038
042
045
052
057
065
075
085
21,4
27,8
37,2
39,6
41,3
48,0
54,9
62,2
73,5
78,4
Absorbed power
6,8
9,6
12,4
14,1
13,5
16,0
18,1
22,1
24,5
27,9
Net EER
3,13
2,90
3,00
2,81
3,06
3,00
3,03
2,81
3,00
2,81
21,2
27,55
36,1
39,8
41,9
47,7
58,2
62,6
76,5
81,5
5,6
7,56
10,4
11,8
11,9
13,8
16,6
19,8
22,4
25,3
3,76
3,65
3,47
3,38
3,50
3,45
3,50
3,31
3,42
3,22
(1)
kW
(2)
(1)
Absorbed power
Net COP
kW
(2)
Auxiliary heating
Gas heat capacity
(S/H) (4)
Electric heater capacity
(S/H) (4)
19/43 19/43 19/43 19/43 31/56 31/56 31/56 31/56 56/112 56/112
kW 18/36 18/36 18/36 18/36 27/54 27/54 27/54 27/54 27/54 27/54
18/36 18/36 18/36 18/36 24/48 24/48 24/48 24/48 36/72 36/72
kW)
50
59
63
66
84
93
103
109
178
186
1/1
2/1
2/1
2/1
2/2
3/2
4/2
4/2
4/2
4/2
Refrigeration circuit
Number of compressors/Number of circuits
Refrigerant charge per circuit
kg
6,1
6,1
8,1
8,1
11,5
11,6
15
15,2
21
21
48
46
46
46
48
46
46
46
48
48
4200
5700
6300
6900
7100
8300
9900
3600
4600
5100
5500
5700
6700
7900
8900
5600
6800
8400
8400
9700
80
80
81
81
83
83
84
84
83
84
77
77
78
79
80
80
81
82
80
81
71
76
78
80
74
83
81
83
83
84
Ventilation data
Nominal airflow rate
Minimum airflow rate
m /h
3
10500 10500
dB(A)
(3) The cooling and heating operating limits are given for steady state running
condition with noted temperature condition
(4) S = Standard heat
H = High heat
34
GC15-E_V1
B
A
D
BAC/BAH/BAG/BAM
024
A
B
C
D
030
038
042
045
052
2259
2283
1260
435
mm
057
065
075
2259
2783
1260
435
085
2259
3663
1260
435
kg
556
591
641
644
772
803
887
911
1092
1100
599
634
684
687
827
858
942
966
1162
1170
618
653
703
706
849
880
964
988
1222
1230
kg
NON ADJUSTABLE,
NON ASSEMBLED
ROOFCURB
MULTIDIRECTIONAL
ROOFCURB
ADJUSTABLE
ROOFCURB
A
A
BAC/BAH/BAG/BAM
024
030
Non-adjustable, non assembled roofcurb
A
B
C
mm
038
042
045
052
057
065
075
085
2123
1818
415
2123
2217
415
2123
2719
415
2225
1719
495
2225
2318
495
2225
2818
495
2222
2260
795
2222
2763
795
mm
mm
2222
1808
795
GC15-E_V1
35
BALTIC
Roofcurbs dimensions and weights
HORIZONTAL EXTRACTION BOX
BAC/BAH/BAG/BAM
024
030
038
042
045
052
057
065
075
085
B
C
1872
2349
2731
2323
2323
2127
1110
1110
1110
B
C
980
980
980
1159
1659
2159
720
720
720
Principle sketches
BALTIC
(vertical flow)
BALTIC
MULTIDIRECTIONAL ROOFCURB
Fresh air
Return air
3
Exhaust air
Supply air
BALTIC
HORIZONTAL EXTRACTION BOX
36
GC15-E_V1
BALTIC
VERTICAL EXHAUST ROOFCURB
Supply fan
Economiser damper
Multidirectional roofcurb
Exhaust roofcurb
Flexair
Air cooled rooftop packaged unit
85 220 kW
Main applications
Large and light commercial buildings
Cinemas, theatres
Industrial buildings and logistic centers
General description
Rooftop solution is the most cost effective package solution
for high efficiency comfort air conditioning of single volume
buildings.
First class efficiency system thanks to multiscroll
compressor technology associated with chlorine free
R410A refrigerant. The rooftop unit product line is
Lennox most innovative equipment for commercial
applications.
Advanced CLIMATIC controller, designed to improve
energy efficiency and reliability. This controller
integrates master slave capability and a wide choice of
communication interfaces.
Cost effective package solution for fast and easy
installation.
Low weight construction for easy lifting in all site
configurations.
Many standard airflow configurations and wide range of
adjustable roof curbs to suit all type of building designs.
Multiple auxiliary heating options available, with intelligent
control to allow the selection of the most efficient way
to generate heating based on the outside temperature
and/or energy costs.
Fresh air control and free cooling/heating management
for healthy and comfortable environments.
Heat recovery solutions on exhaust air through an
enthalpic wheel.
The units are available with the following versions:
> Heat pump
> Multiple fuels units combine heat pump with gas fired
heating
Main components
R410A scroll compressors
EN 60204-1 electrical cabinet with circuit breaker
Voltage 400V/3Ph/50Hz
High efficiency EC fan motor
CLIMATIC controller
Full text fault display and history.
Many settings and readings available for customization
and diagnostic.
GC15-E_V1
37
FLEXAIR
High efficiency rooftop for long lasting energy saving
Axial fans with swept blades
eDrive EC fans
Gas burner
year round
R410A refrigerant for best efficiency
Electronic expansion valves for optimum control in all
conditions
Optimised heat exchanger surface area to boost system
energy
Net EER
4,5
MultiScroll + eDriveTM
4,0
Multi-Scroll
3,5
Inverter Scroll
3,0
Single Scroll
2,5
2,0
1,5
10
20
30
40
50
60
70
80
90 100
38
GC15-E_V1
General data
FLEXAIR
085
100
120
150
170
200
230
84,1
98,3
115,1
143,4
158,8
184,8
223,0
26,0
33,7
40,4
51,7
59,9
64,0
78,6
3,24
2,92
2,85
2,77
2,65
2,89
2,84
80,3
97,7
113,2
137,6
161,4
191,2
231,6
23,7
29,5
37,6
40,7
49,9
55,7
75,0
3,39
3,32
3,01
3,38
3,29
3,43
3,09
kW - S/H (4)
55,2/110,4
110,4/165,6
165,6/220,8
kW - S/M/H (4)
30/54/72
45/72/108
72/108/162
2/2
3/2
4/2
15,1 +
14,5
18,5 +
18,5
19,8 +
19,8
46
m3/h
15000
18500
20500
26000
30000
35000
39000
12000
14000
15000
18000
21000
24000
27000
23000
23000
23000
35000
35000
43000
43000
80,2
88,5
89,2
86,8
85,9
84,9
85,4
75
82
86
81
82
79
81
86,3
82,7
97,6
91,4
95,2
91,3
92
dB(A)
GC15-E_V1
39
FLEXAIR
Dimensions and weights
F BOX
G BOX
H BOX
C
C
B
B
A
D
FLEXAIR
085
View
100
120
150
A
B
C
D
2245
3315
1750
360
mm
170
200
2245
4360
1885
456
230
H
2260
5166
2235
620
kg
966
1055
1054
1454
1550
2027
2143
kg
1013
1117
1108
1576
1681
2257
2371
kg
1083
1187
1178
1599
1704
2297
2411
ADJUSTABLE ROOFCURB
MULTIDIRECTIONAL ROOFCURB
C
C
B
B
FLEXAIR
Non-adjustable, non
assembled roofcurb
Assembled adjustable
roofcurb
Multidirectional roofcurb
40
GC15-E_V1
CENTRIFUGAL RETURN
ROOFCURB
(vertical and horizontal)
mm
mm
mm
mm
mm
2059
2771
410
2159
2872
400
2154
2745
840
2256
3005
1220
2083
2805
1220
2059
3466
410
2159
3567
400
2154
3441
1140
2256
3496
1220
2083
3293
1220
2059
4066
425
2159
4167
425
2154
4067
1340
2256
3493
1220
2083
3293
1220
B
A
Principle sketches
FLEXAIR
(vertical flow)
MULTIDIRECTIONAL ROOFCURB
2
2
3
3
65
2
1
Fresh air
Return air
Exhaust air
Supply air
Supply fan
Exhaust damper
Multidirectional roofcurb
Return/Exhaust fan
GC15-E_V1
41
Standard features
Energy efficiency and comfort
eDrive :
Free cooling/heating :
CLIMATIC Description
CLIMATIC general description
This microprocessor based control, CLIMATIC equips the
Lennox rooftop range. It is designed to provide best energy
efficiency throughout the unit life cycle while ensuring reliable
and consistent operation.
CLIMATIC integrates innovative PID control that will guaranty
better temperature accuracy, while saving energy. Main functions are :
Compressor running time optimization
Scheduling capability.
Control of multiple rooftops units.
Service display :
Comfort display :
C L I M AT I C o f f e r s d i f f e r e n t f u n c t i o n a l i t i e s a n d
communications options : master slaved, GTC interfaces
through Modbus, Lonworks and Bacnet, and ADALINK
II, the fully integrated Lennox solution to control up to
16 units on the same site.
42
GC15-E_V1
Options
Auxiliary heating
Energy recovery
Refillable G4 filter :
Energy meter :
Double skin :
Electric heater
Gas burner
GC15-E_V1
43
44
GC15-E_V1
BALTIC WSHP
FLEXY WSHP
46 92 kW
95 196 kW
Main applications
Large commercial buildings (retail, airports, shopping malls)
Cinemas, theatres
Buildings equipped with water loop
General description
Water source heat pump systems are composed of individual
packaged units that transfer heat via a single water loop.
Each unit can be used in either heating or cooling mode year
round and loop temperature is maintained via a cooling-only
and boiler or heat pump chiller plus dry-cooler combination
and/or geothermal loop. Lennox water source rooftop units
provide the most energy efficient solution for comfort air
conditioning of single volume buildings.
First class efficiency system thanks to scroll compressor
technology associated with environmentally friendly
R410A refrigerant and high performance water plate
heat exchanger.
The water source heat pump rooftop unit product line is
Lennox most innovative and flexible equipment for large
integrated commercial applications: each unit being
independent from the other it can be independently
controlled.
Very low noise solution as there is no outdoor fans on
the unit.
Advance CLIMATIC controller, designed to improve energy
efficiency and reliability. This controller integrates master
slave capability and a wide choice of communication
interfaces.
All in one cost effective package solution for fast and easy
installation.
Low weight construction for easy lifting in all site
configurations.
Many standard airflow configurations and wide range of
adjustable roof curbs to suit all type of building designs.
Auxiliary heating options available with intelligent control to
allow the selection of the most efficient way to generate
heat based on the outside temperature and/or energy
costs.
Fresh air control and free cooling/heating management
for healthy and comfortable environments.
The units are available with the following versions:
> Heat pump
> Multiple fuels units combine heat pump with gas fired
heating
Main components
R410A scroll compressors
Compact Stainless steel plate heat exchanger with low
CLIMATIC controller
Full text fault display and history.
Many settings and readings available for customization
and diagnostic.
GC15-E_V1
45
General data
BALTIC WSHP
WSHP
FLEXY WSHP
045 052 057 065 075 085 085 100 120 150 170
52,0
59,6
68,9
82,9
88,6
87,9
11,4
13,7
15,2
19,0
21,6
25,0
21,4
27,6
32,1
35,8
44,5
Net EER
4,10
3,81
3,92
3,63
3,84
3,54
4,11
4,02
3,80
4,41
3,87
62,2
70,7
82,4
95,2
14,1
16,0
18,7
23,1
25,0
29,5
25,9
32,6
38,1
42,7
57,4
4,42
4,41
4,42
4,12
4,41
4,11
4,41
4,13
4,10
4,67
4,14
(1)
kW
(2)
(1)
kW
(2)
Auxiliary heating
Gas heating capacity
Standard heat/High heat
kW S/H (3)
kW S/M/H (3)
30,7/55,8
55,8/112,0
55,2/110,4
110,4 / 165,6
30/54/72
45/72/108
27/54
kW S/H (3)
24/48
36 / 72
84
93
103
109
178
186
134/
210
149/
236
156/
250
169/
301
180/
326
2/2
3/2
4/2
4/2
4/2
4/2
2/2
2/2
2/2
3/2
4/2
kg
6,8
6,8
7,8
9,1
10,0
10,5
10,0
10,5
10,5
16,0
16,0
kPa
27
35
22
31
42
47
60
58
58
76
64
Inlet/outlet connections
DN
65
65
65
65
65
65
65
65
65
80
80
7100
8300
m /h 5700
6700
7900
kW S/H (3)
Refrigeration circuit
Number of compressors/Number of circuits
Refrigerant charge per circuit
Hydraulic circuit
Ventilation data
Nominal airflow rate
Minimum airflow rate
9700 11200 13100 13100 17000 19000 23000 23000 23000 35000 35000
Acoustic data
Outdoor sound power
Standard unit
Indoor blower outlet sound power
Standard unit
72
74
76
79
78
80
76
78
78
80
83
78
81
85
87
87
89
85
90
89
91
94
dB(A)
Note:
(1) All data at EUROVENT conditions
Cooling : water inlet 30C - 27C DB 47% / 19C WB
Heating : water inlet 20C - 20C 60% / 15C WB)
Nominal airflow rate, nominal external static pressure, 400 V/3 Ph/50 Hz)
46
GC15-E_V1
WSHP
045
052
View
BALTIC
057 065
1
075
085
085
100
2259
B
C
3283
3348
1260
170
2290
2783
mm
FLEXY
120 150
2
4385
1510
435
1830
415
Weight
Standard unit
kg
760
795
842
876
987
1007
790
874
955
1237
1300
819
854
913
931
1077
1079
897
981
1062
1478
1541
841
876
935
953
1135
1137
967
1051
1132
1501
1564
MULTIDIRECTIONAL
ROOFCURB
C
ADJUSTABLE ROOFCURB
C
B
A
A
WSHP
Non-adjustable, non
assembled roofcurb
Assembled adjustable
roofcurb
Multidirectional roofcurb
(External dimensions. No roof
opening required )
FLEXY
2123
2123
2059
2059
2217
2719
2771
3466
415
415
410
410
2225
2225
2159
2159
2318
2818
2872
3567
495
495
400
400
2222
2222
2154
2154
2260
2763
2745
3441
795
795
840
1140
2349
2731
2256
2256
2323
2127
3127
4193
1110
1110
1220
1220
2083
mm
980
980
2083
1659
2159
3041
4107
720
720
1220
1220
CENTRIFUGAL RETURN
ROOFCURB
BALTIC
GC15-E_V1
47
Standard features
Energy efficiency and comfort
eDrive :
Free cooling/heating :
CLIMATIC Description
CLIMATIC general description
This microprocessor based control, CLIMATIC equips the
Lennox rooftop range. It is designed to provide best energy
efficiency throughout the unit life cycle while ensuring reliable
and consistent operation.
CLIMATIC integrates innovative PID control that will guaranty
better temperature accuracy, while saving energy. Main functions are :
Compressor running time optimization
Scheduling capability.
Control of multiple rooftops units.
Service display :
Comfort display :
C L I M AT I C o f f e r s d i f f e r e n t f u n c t i o n a l i t i e s a n d
communications options : master slaved, GTC interfaces
through Modbus, Lonworks and Bacnet, and ADALINK
II, the fully integrated Lennox solution to control up to
16 units on the same site.
48
GC15-E_V1
Options
Auxiliary heating
Energy recovery
Refillable G4 filter :
Energy meter :
Double skin :
Electric heater
Gas burner
GC15-E_V1
49
FX
25 162 kW
Main applications
Cinemas, theatres, convention centers
Large and light commercial buildings (retail, airports,
restaurants)
air.
CLIMATIC
Fresh air
Supply air
Return air
Extraction
General description
Rooftop FX solution is the most cost effective package solution for high efficiency comfort air conditioning of buildings
using high volumes of fresh air.
First class efficiency system thanks to the full
thermodynamic heat recovery 4 dampers systems
High flexibility with two centrifugal fans (exhaust and
supply) allowing full modulation of the air balancing in
the building and control of exhaust and fresh air mix.
Perfect control of the pressure inside the building to limit
the risk of door opening due to pressure differences.
Unit can be fully ducted (supply and exhaust) allowing
indoor installation when required.
Available as heat pump only the unit is also available for
100% fresh air application down to -10C outside air
Advance CLIMATIC controller, designed to improve energy
efficiency and reliability. This controller integrates master
slave capability and a wide choice of communication
interfaces.
50
GC15-E_V1
Main components
R410A compressors
EN 60204-1 electrical cabinet with circuit breaker
feature
CLIMATIC controller
16 bits, 21 megabytes flash memory processor
Can display 50 different faults
100 settings and 100 readings available for customization
and diagnostic
General data
FX
025 030 035 040 055 070 085 100 110 140 170
Cooling mode
Gross cooling capacity
Gross EER
(1)
kW 24,7
28,6
32,5
41,1
49,8
67,3
81,0
3,04
3,15
3,50
3,12
3,14
3,91
3,68
4,13
kW 22,8
25,8
28,1
34,9
43,6
59,3
72,7
3,34
3,31
3,97
3,81
3,86
4,85
4,63
4,27
4,44
4,81
4,48
2/2
2/2
2/2
2/2
2/2
2/2
2/2
2/2
4/4
4/4
4/4
(1)
4,14
4,45
4,01
Heating mode
Net heating capacity
Net COP
(1)
(1)
Refrigerant circuit
Number of compressors/Number of circuits
Refrigerant charge per circuit
kg
4,6
4,6
10,8
10,8
10,8
14,3
14,3
14,3
11,3
11,3
11,3
40
39
42
41
42
42
42
44
44
43
41
Ventilation
Nominal airflow rate at 150 Pa
4000 5000 6000 7200 9000 10800 13500 17300 19000 24000 27000
m /h 3200 4000 4800 5800 7200 8600 10800 13800 15200 19200 24000
3
(1)
4500 5500 6600 8100 9900 12200 15400 18200 21500 25500 30000
Acoustic data
Outdoor sound power level
dB(A)
85
87
83
84
89
90
94
95
92
96
98
80
83
78
80
83
84
88
93
87
91
93
(1) : All data at summer operating conditions : 35C DB - 27C DB 47% / 19C WB - 25% fresh air
Winter operating conditions : 7C DB - 20C - 25% fresh air
Cooling capacities at nominal airflow rate. Please use the multiplier 1,02 to obtain the cooling capacities to maximum airflow rate.
2 Roofcurb
FX
3 Supporting frame
25
30
35
40
55
70
85
100
110
140
170
3970
3970
4750
4750
4750
5050
5050
5050
5650
5650
5650
1610
1610
2255
2255
2255
2255
2255
2255
2255
2255
2255
1055
1055
1340
1340
1340
1725
1725
1725
2150
2150
2150
1540
1540
2175
2175
2175
2175
2175
2175
2175
2175
2175
3960
3960
4730
4730
4730
5040
5040
5040
5630
5630
5630
1540
1540
2175
2175
2175
2175
2175
2175
2175
2175
2175
3960
3960
4725
4725
4725
5040
5040
5040
5630
5630
5630
950
980
1400
1450
1600
1800
1900
2000
2300
2400
2600
mm
mm
mm
Weight
Weight
Standard unit
kg
GC15-E_V1
51
FLEXY
FX
Option
FAC/FHA
Standard equipment
FLEXAIR
BALTIC
BAC/BAH
BAG/BAM
Energy recovery
Refrigerant
R410A
Leak detection
Electronic pressure sensors
Shrader valves on facade
Compressors
Multiscroll
Tandem (1)
Silent start
Refrigerant lock-out safety
Compressor noise jacket
Electronic (& bi-flow for heat pump)
Expansion valves
(2)
Condenser fans
Economiser
Casing
Insulation
Air filter
Anti-corrosion protection
52
GC15-E_V1
(2) : BALTIC air to air : from 45 kW / FLEXAIR and eNeRGy : depending on models
Non contractual photos
FLEXY
FX
FAC/FHA
FLEXAIR
Option
BALTIC
Standard equipment
BAC/BAH
BAG/BAM
Roofcurbs
Packing
Container packing
CLIMATIC 60
eClimatic
CLIMATIC 50
Regulation on supply or ambiant temperature
Regulation on ambiant temperature only
7 time zones per day with 4 different operating modes
4 time zones per day with 1 operating mode each
Dirty filter alarm
Dynamic defrost
Alternate defrost (2)
Morning anticipation
Dynamic setpoint
Variable airflow management of supply fan
eFlow airflow rate on display
Variable airflow management of condenser fan
Economiser power stage & free-cooling/heating
Economiser power stage & free-cooling
Heat recovery module power stage
Compressors capacity steps (up to 4)
Smoke detector
Fire thermostat
Soft starter/Air sock control
CO2 control
Humidity control
Energy meter
(2) : BALTIC air to air : from 45 kW / FLEXAIR and eNeRGy : depending on models
Non contractual photos
GC15-E_V1
53
Option
WSHP
Standard equipment
FLEXY II
WSHP
BALTIC
Energy recovery
Refrigerant
Compressors
(1)
Silent start
Refrigerant lock-out safety
Compressor noise jacket
Electronic (& bi-flow for heat pump)
Expansion valves
(2)
Economiser
Casing
Insulation
Air filter
EU4
Refillable EU4
EU4 + F7
Anti-corrosion protection
Up supply
Downflow return
Horizontal return
Up return
54
GC15-E_V1
(2) : BALTIC air to air : from 45 kW / FLEXAIR and eNeRGy : depending on models
Non contractual photos
WSHP
FLEXY II
Option
WSHP
Standard equipment
BALTIC
Roofcurbs
Adjustable roofcurb
Multidirectional horizontal flow roofcurb
Packing
Container packing
CLIMATIC 60
Regulation on supply or ambiant temperature
7 time zones per day with 4 different operating modes
Dirty filter alarm
Morning anticipation
Dynamic setpoint
Variable airflow management of supply fan
eFlow airflow rate on display
Economiser power stage & free-cooling/heating
Heat recovery module power stage
Compressors capacity steps (up to 4)
Auxiliary heating capacity steps
Intelligent fresh air management (Patent 03 50616)
GC15-E_V1
55
56
58
60
64
70
76
57
AQUALEAN
2 20 kW
Main applications
Office buildings
Hotels
Shopping malls
Buildings with water loop
General description
AQUALEAN is a water source heat pump packaged unit
designed to provide high efficiency comfort air conditioning
and ventilation for shopping areas and open-plan or cellular
offices of large buildings. Each unit answers to the heating
or cooling load of the individual zone it serves to ensure an
excellent comfort level for occupants, better control of energy
use for buildings owners and lower seasonal operating cost.
It is generally connected to a closed water loop (boiler/cooling tower or geothermal application) or to an open ground
water loop.
This water source heat pump is one of the most efficient, environmentally friendly system available for cooling and heating :
High efficiency system thanks to scroll compressor
operating with chlorine free and zero Ozone Depletion
Potential R410A refrigerant
Compact self-supporting casing with very short height to
lower dropped ceilings dimension
eDrive variable speed direct transmission ventilation
system to save energy on ventilation-driven costs
Main components
R410A compressor
Advanced microprocessor control
Electronic expansion valve
Coaxial water/refrigerant heat exchanger (sizes 02/03)
Brazed water/refrigerant heat exchanger (sizes 07/22)
Copper-Aluminium air/refrigerant heat exchanger
M0 fire-class insulation
G2 filter
Galvanized steel casing
Options
BMS possibility : Master/slave, Modbus, BACnet,
LonWorks
58
GC15-E_V1
General data
AWC/AWH
02
03
07
08
10
12
15
18
20
2,0
2,8
6,8
8,0
10,2
11,2
14,5
17,0
19,0
0,5
0,7
1,7
2,1
2,6
2,8
3,4
4,2
4,8
3,8
4,0
4,0
3,8
3,9
4,0
4,3
4,0
4,0
2,5
3,6
8,0
9,5
12,3
13,5
17,0
19,5
22,0
0,6
0,9
2,1
2,5
3,2
3,6
4,6
5,1
6,0
3,9
4,0
3,8
3,8
3,8
3,8
3,7
3,8
3,7
(1)
kW
Absorbed power
Net EER
(2)
kW
Absorbed power
Net COP
Eletrical data
230V/1Ph/50 Hz
Voltage
400V/3Ph/50Hz
Refrigerant circuit
Number of compressors/Number of circuits
1/1
Kg
0,575
0,65
1,25
1,35
2,2
2,3
2,5
2,8
430
575
1200
1500
1900
2100
2350
2800
3100
275
350
960
1250
1520
1680
1750
2240
2500
Maximum airflow
440
650
1400
1600
2300
2400
2600
3400
3500
50
50
50
50
50
50
50
70
70
Minimum airflow
Pa
40 C
l/h
495
560
1390
1650
2100
2320
2980
3480
3960
30
29
25
30
40
48
35
45
55
29
26
23
28
38
46
33
43
53
2/3/5
2/3/5
52/54
62/64
66/69
65/68
kPa
Auxiliary heating
Electric heater capacity
S/M/H (3)
kW
Acoustic data
Sound power level
Supply ductwork
(4)
dB(A) 46/48
67/70
69/72
66/70
69/73
Operating limits
Maximum water inlet temperature (5)
Cooling mode
Minimum water inlet temperature (5)
Cooling mode
Maximum water inlet temperature (5)
Heating mode
Minimum water inlet temperature (5)
Heating mode
45C
15C (6)
35C
10C (6)
10C
1/2" G
1" G
Hydraulic connections
Connection diameter
(1) Air inlet temperature : 27 C DB/19 C WB - Water inlet temperature :
30 C at nominal water flow.
(6) Minimum water inlet temperature = 0C with low water temperature kit.
AWC/AWH
02
A
B
08
10
12
15
18
20
792
1083
1503
500
492
623
703
230
440
490
530
mm
kg
07
1000
C
Weight
Standard unit
03
50
55
77
80
105
110
120
160
165
GC15-E_V1
59
FLATAIR
10 28 kW
Main applications
Stores in urban area
Small size office buildings
Bank offices
Restaurant & Bars
General description
Options
Auxiliary heating
Electrical heater (1 stage): add an auxiliary heating stage
to heat pump or cooling units : Standard, Medium, High.
Main components
R410a scroll compressor
Ductable supply and condenser
(depending on sizes).
60
GC15-E_V1
General data
FMC/FMH
10
10
12
15
20
25
30
Cooling mode
Net cooling capacity
(1)
Absorbed power
kW
10,1
12,0
14,9
19,3
23,2
26,7
kW
3,3
5,4
6,1
8,3
10,1
12,2
3,05
2,23
2,43
2,33
2,30
2,50
kW
10,0
12,6
15,6
20,7
25,3
28,2
kW
3,21
4,6
5,7
7,2
9,1
10,4
3,12
2,72
2,74
2,89
2,77
2,71
Net EER
Heating mode
Net heating capacity
(2)
Absorbed power
Net COP
Electrical data
Voltage
Indoor unit and outdoor unit
V/Ph/Hz
230/1/
50
400/3/50
Refrigerant circuit
Number of compressors /Number of circuits
Refrigerant charge per circuit
Cooling only
Refrigerant charge per circuit
Heat pump
1/1
2,14
2,57
3,55
4,46
5,38
6,15
2,5
2,93
4,0
4,9
6,3
7,0
1500
1650
2410
3090
3455
3695
2350
2300
3575
4850
5750
5500
120
110
160
200
240
180
2350
2400
3740
4095
4760
5000
3500
3400
4500
5650
6000
5850
Pa
100
90
120
150
160
100
kW
3/6/9
kg
m3/h
Pa
Auxiliary heating
Electric heater capacity
S/M/H (3)
4,5/6/9
7,5/9/12
Acoustic data
Sound power level
Air treatment unit
(4)
72
76
80
84
83
77
82
86
81
81
dB(A)
Refrigerant connections
Connection - Liquid
3/8"
3/8"
1/2"
5/8"
Connection - Gas
3/4"
3/4"
7/8"
1 1/8"
(1) : Indoor air: 27C DB, 19C WB - Outdoor air: 35C DB, 24C WB
(2) : Indoor air: 20C DB, 12C WB - Outdoor air: 7C DB, 6C WB
(3) : Available as an option
S = Standard heat - M = Medium heat - H = High heat
(4) : EUROVENT conditions data.
GC15-E_V1
61
FLATAIR
Operating limits
CONDENSING UNIT
FSC/FSH
10
10
12
15
20
25
30
44
41
Cooling mode
Maximum indoor temperature
32C DB / 23C WB
21C / 15C WB
C
45
45
43
45
44
Heating mode
Maximum indoor temperature
27C DB
15C DB
C
25
25
23
25
25
23
25
-12C
FIX/FIC/FIH
Air treatment section
FIX/FIC/FIH
10
12
15
20
25
30
430
430
500
620
775
775
1250
1250
1300
1450
1500
1500
500
500
595
595
645
645
58
58
85
109
121
131
mm
B
C
Weight
62
GC15-E_V1
kg
FLATAIR
Dimensions and weights
A
FSC/FSH
Condensing unit
FSC/FSH
10
12
15
20
25
30
820
820
830
900
1025
1025
1250
1250
1300
1450
1500
1500
500
500
595
595
645
645
117
121
170
164
207
213
mm
C
Weight
kg
FMC/FMH
Monobloc unit
FMC/FMH
A
B
mm
C
Weight
kg
10
12
15
20
25
30
1250
1250
1330
1520
1800
1800
1250
1250
1300
1450
1500
1500
500
500
595
595
645
645
175
179
255
273
327
343
GC15-E_V1
63
COMPACTAIR
20 100 kW
Main applications
Retail premises in urban area
Shopping malls
Industry
General description
COMPACTAIR can be used for for medium to large commercial cooling and heating applications in urban building, where
architectural protection is mandatory and roof access difficult.
Made for indoor installation.
It exists in the following versions:
Monobloc
Split
Cooling only & heat pump
Economizer with multiple airflow configuration
Main components
Vertical construction with small footprint
Centrifugal fans in supply section with external static
64
GC15-E_V1
CLIMATIC Controller
Full text fault display and history.
Many settings and readings available for customization
and diagnostic.
GC15-E_V1
65
COMPACTAIR
General data
COMPACTAIR
20S
Monobloc
Split
25S
30S
35S
40S
CMC/CMH
CSC/CSH - CIC/CIH
45D
55D
70D
85D 100D
NA
A
COMPACTAIR
20S
25S
30S
35S
40S
45D
55D
70D
85D 100D
17,6
22,7
26,7
34,5
40,0
42,9
54,9
68,2
81,2
101,0
7,1
9,9
11,6
14,5
16,7
19,1
23,1
29,7
34,9
40,4
2,48
2,29
2,30
2,37
2,39
2,24
2,37
2,30
2,32
2,87
19,5
25,3
29,8
36,5
42,5
50,3
60,1
70,8
82,8
101,0
7,0
9,1
11,3
13,2
14,9
18,6
21,9
26,7
30,8
35,4
2,77
2,77
2,63
2,76
2,86
2,7
2,74
2,65
2,69
2,85
2/2
2/2
3/2
9,5
15,2 +
10,56
(1)
kW
(1)
(1)
(1)
(1)
Net COP
kW
(1)
Electrical data
Voltage
400V/3 Ph/50 Hz
Refrigerant circuit
Number of compressors/Number of circuits
Refrigerant charge per circuit
1/1
kg
1/1
1/1
1/1
1/1
2/2
2/2
4,5
5,5
6,2
8,0
9,3
5,3
6,3
8,0
3150
4250
4650
6200
6950
7950
9950
4100
5500
6000
8050
9050
9750
685
672
650
729
833
812
m3/h 7600
8500
m3/h
Pa
747
680
812
Condensing section
Nominal airflow rate
Maximum available static pressure
Pa
178
223
209
205
237
299
272
277
15500 +
11700
239 +
201
Auxiliary heating
Electrical heater capacity
S/M/H (3)
kW
kW
(2)
10/15/20
15/20/27
27/40/
50
20/27/40
31
38
40
56
61
66
91
105
113
171
82
85
86
85
85
88
87
88
89
92
75
76
77
76
76
78
78
79
80
83
77
79
80
79
81
82
82
82
83
76
76
77
77
78
80
78
80
81
75
82
82
82
85
86
80
85
87
85
45
45
45
47
47
45
45
47
47
47
Acoustic data
(1)
(1)
(1)
dB(A)
Operating limits
Maximum outdoor temperature
Cooling mode
Minimum outdoor temperature
Cooling mode
Minimum outdoor temperature
Heating mode
(1) EUROVENT conditions data
Cooling :
Outdoor temperature = 35C DB
Entering coil temperature 27C DB / 19C WB
Heating :
Outdoor temperature = 7C DB / 6C WB
Indoor temperature = 20C DB
66
GC15-E_V1
Refrigerant connections
COMPACTAIR
Connection - Liquid
Connection - Gas
20S
25S
30S
35S
40S
45D
55D
70D
85D
100D
Circuit 1
1/2"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
3/4"
Circuit 2
5/8"
5/8"
5/8"
5/8"
5/8"
Circuit 1
7/8"
Circuit 2
Monobloc unit
CMC/CMH
CMC/CMH
20S
30S
35S
40S
1194
mm
B
C
Operating weight
25S
kg
(1)
376
45D
55D
70D
1445
840
960
960
2055
2145
2145
412
424
516
85D
2251
539
630
785
831
883
Condensing unit
CSC/CSH
Sizes 100D
Slave section
1410
Master section
CSC/CSH
20S
A
mm
B
C
Operating weight
25S
30S
35S
kg
262
45D
55D
70D
85D 100D
1445
2251
2900
745
870
870
870
1410
(1)
40S
1194
295
1410
302
357
370
1410
448
529
554
1410
586
870
CIC/CIH
20S
A
mm
B
C
Operating weight
25S
30S
35S
kg
108
45D
55D
70D
85D 100D
1194
1445
2251
2900
840
960
960
1140
645
(1)
40S
111
735
115
150
160
735
170
242
259
1140
276
470
GC15-E_V1
67
COMPACTAIR
Dimensions and weights
CIC/CIH
Return fan
CMC/CMH
55D
CIC/CIH
55D
70D
85D
100D
70D
85D
100D
2250
mm
B
C
Approximate operating weight
kg
(1)
310
CIC/CIH
2900
650
700
735
1140
310
310
420
CMC/CMH
20S
25S
30S
35S
40S
45D
55D
70D
85D 100D
CIC/CIH
20S
25S
30S
35S
40S
45D
55D
70D
85D 100D
A
mm
B
C
1195
1445
2250
2900
674
697
1150
1150
645
(1)
kg
50
50
740
50
75
75
740
75
165
165
1140
165
190
Principle sketches
With economizer
Sizes 20S to 45D
With economizer
Sizes 55D to 100D
Fresh air
Return air
Exhaust air
Supply air
68
GC15-E_V1
COMPACTAIR
Options
Energy efficiency and comfort
eDrive: eDrive is an optional feature of Lennox COMPACTAIR
units. It is a variable speed, direct transmission ventilation
system that saves energy and reduces maintenance costs.
CLIMATIC controls eDrive and automatically adjusts the
airflow rate to the exact building needs, saving up to 30%
annual COMPACTAIR energy consumption. eDrive is a
direct transmission system without pulleys nor belts. It
eliminates friction losses improving energy efficiency even
at full speed.
Free cooling/heating: Thermodynamic cooling or heating
can be replaced by free-cooling/heating when outdoor
temperature are favorable (below/above the building set
point), saving up to 30% on annual energy consumption.
Accurate percentage of fresh air: Managing fresh air is
mandatory in a building to control CO2 level and comfort.
Introducing just the required amount of fresh air in a
building can reduce energy consumption. This feature
ensures a better CO2 management while saving energy
by reducing the amount of cooling or heating to treat the
extra fresh air.
Dynamic defrost control: dynamic defrost is Lennox
answers to unnecessary defrost cycles. Dynamic defrost
detects icing of the coil by monitoring the difference
between refrigerant and outside temperature and starts
the defrost cycle only when required. This feature allows
significant energy savings by reducing the number of
defrost cycles when they are not necessary.
Exhaust fan module: this ensures overpressure extraction
in case of high level of fresh air inlet.
Return module: the return fan enables to overcome the
return duct pressure drop, particularly during freecooling
operation.
Indoor air quality
Safety
M0 fire-proof insulation : COMPACTAIR features M0 rock
or glass whool insulation as an option.
Smoke detector: The optical head of the smoke detector
can detect any type of smoke. When this occurs the unit
will stop operating, the return air damper will close fully
and the fresh air damper will open fully.
Refrigeration options
Long refrigerant piping: allows up to 65m piping between
the internal and external units.
Shut off service valve: facilitates installation & service
operations. Includes a valve on the gas loop side and a
valve on the liquid loop side of split units.
Refrigerant pre-charged: split condenser supplied with
factory filled refrigerant pre-charge. Includes shut off
service valves, on liquid and gas loop sides.
Electrical and safety
Main switch: installed on the electrical panel of the
condensing unit. The unit turns off when the board panel
is opened.
Phase sequencer: this device prevents the compressor
from starting if the phases are reversed.
Other options
Low noise & winter operation with inverter control:
reduce radiated noise and noise in duct at condenser
are reduced down to 9dBa. Cooling operations are also
possible down -15C.
Precoated coil: outdoor or indoor coils anticorrosion
treatment. Particularly recommended in salin or polluted
environment.
GC15-E_V1
69
AIRCOOLAIR
19 134 kW
Main applications
Retail premises in urban area
Shopping malls
Industry
Building air conditioning combined with air handling unit
General description
AIRCOOLAIR SPLIT UNIT can be used for medium to large commercial cooling and heating applications when the premises
are not directly accessible from the roof.
It exists in the following versions :
Cooling only & heat pump
Freecooling
AIRCOOLAIR CONDENSING UNIT is the outdoor unit without the supply section. This unit is available as cooling only or as
heat pump and can be combined with air handling units. It provides you with a low noise level, high efficency and flexibility
in the installation.
Main components
R410A refrigerant
Sealed scroll compressor
Centrifugal fans in supply section
Axial condenser fan in outdoor section
Galvanized sheet steel framework with fork lift pockets
70
GC15-E_V1
Control
All units are equipped with:
Dynamic defrost control
Dynamic set point
Time schedule programmer
CLIMATIC control for advanced comfort & communication
devices: master -slave, multi-unit display, BMS
communication or Lennox ADALINK II supervision
Advanced default analyse, enthalpy and humidity control
(optional), CO2 level control (optional), stepped and
modulating auxiliary heaters
General data
AIRCOOLAIR
Split
Condensing unit
ASC/ASH - CIC/CIH
ASC/ASH
NA
SPLIT UNIT
20S
25S
30S
35S
40S
45D
19,3
6,9
2,80
23,2
8,7
2,66
26,7
10,1
2,64
35,0
12,9
2,72
40,0
15,3
2,62
45,7
17,9
2,56
19,7
6,7
2,95
25,3
8,6
2,94
28,8
10,0
2,89
36,5
12,4
2,96
40,5
13,7
2,95
50,3
17,9
2,81
(1)
kW
kW
Electrical data
Voltage
400V/3 Ph/50 Hz
Refrigerant circuit
Number of compressors/Number of circuits
Refrigerant charge per circuit
1/1
1/1
1/1
1/1
1/1
5,72
5,90
6,33
8,84
10,83
2/2
6,94 +
6,94
Pa
3150
4100
450
4250
5500
550
4650
6000
550
6200
8050
550
6950
9050
600
7950
9750
550
m3/h
6800
9750
11500
11300
11000 2x9750
kg
m3/h
Condensing section
Nominal airflow
Auxiliary heating
10/15/20
kW
15/20/27
31
38
40
56
61
66
72
70
75
76
71
82
76
70
82
77
71
82
78
72
85
79
74
86
55D
70D
54,4
20,9
2,61
68,2
26,1
2,61
80,2
31,6
2,54
97,3
38,5
2,53
111,0
38,9
2,85
135,0
48,2
2,80
57,6
19,9
2,9
73,8
25,5
2,9
81,8
28,5
2,87
110,8
37,3
2,97
118
137
3,05
2,82
Acoustic data
Sound power level - Outdoor blower outlet - Standard unit (Lw) (1)
Sound power level - Outdoor blower outlet - Low noise unit (Lw) (1)
Sound power level - Indoor blower outlet (Lw) (1)
dB(A)
SPLIT UNIT
Cooling mode - ASC + CIC - ASH + CIH
Net cooling capacity
Absorbed power (1)
Net EER (1)
(1)
kW
kW
Electrical data
Voltage
400V/3 Ph/50 Hz
Refrigerant circuit
Number of compressors/Number of circuits
Refrigerant charge per circuit
2/2
6,42
+
kg
6,42
2/2
8,74+
8,74
2/2
10,9 +
10,9
3/2
13,5 +
11,6
3/2
17,32 +
11,16
3/2
17,23 +
17,1
9950
12850
Pa 650
12450
15090
650
14000
16725
600
17350
22450
600
19300
24950
550
21000
24750
600
2x
11500
2x
11300
2x
11000
22700 +
18100
22700
+18100
2x
22700
m3/h
Condensing section
Nominal airflow
m3/h
Auxiliary heating
20/27/40
kW
27/40/50
91
105
113
171
183
192
79
73
80
80
74
85
81
75
87
82
76
85
83
76
87
87
81
89
Acoustic data
Sound power level - Outdoor blower outlet - Standard unit (Lw) (1)
Sound power level - Outdoor blower outlet - Low noise unit (Lw) (1)
Sound power level - Indoor blower outlet (Lw) (1)
(1) EUROVENT conditions data
Cooling :
Outdoor temperature = 35C DB
Entering coil temperature 27C DB / 19C WB
Non contractual photos
Heating :
Outdoor temperature = 7C DB / 6C WB
Indoor temperature = 20C DB
dB(A)
71
AIRCOOLAIR
General data
CONDENSING UNIT
020S
025S
030S
035S
040S
045D
055D
19,7
24,7
28,4
36,1
42,0
49,4
56,7
(1)
kW
Absorbed power
Net EER
(1)
6,4
8,1
9,6
11,9
14,1
16,2
19,3
3,06
3,05
2,95
3,03
2,98
3,05
2,94
19,8
25,0
28,6
36,0
40,2
50,1
57,1
kW
(2)
Absorbed power
6,2
7,8
9,2
11,1
12,9
15,6
18,4
Net COP
3,20
3,21
3,12
3,24
2,98
3,21
3,1
(2)
Electrical data
Voltage
400V/3 Ph/50Hz
Refrigerant circuit
Number of compressors/Number of circuits
Capacity steps
1/1
1/1
1/1
1/1
1/1
2/2
2/2
6800
9750
11500
11300
11000
2x
9750
2x
11500
75,9
77,9
83,1
92,1
82,5
80,9
84,0
75,2
75,9
80,8
80,6
80,6
78,9
81,9
070D
085D
100D
120D
140D
200D
230D
72,1
83,9
104
115
141
197
228
23,7
28,3
34,3
37,1
46,2
63,4
58,7
3,04
2,96
3,03
3,1
3,05
3,11
3,06
m3/h
Acoustic data
Sound powel level (1)
Outdoor blower outlet - Standard unit (Lw)
Sound powel level (1)
Outdoor blower outlet - Low noise unit (Lw)
dB(A)
(1)
CONDENSING UNIT
Cooling mode - ASC
Cooling capacity
(1)
kW
Absorbed power
EER
(1)
kW
(2)
71,9
80,3
105
114
137
191
218
Absorbed power
22,2
25,9
32,4
35,6
43,8
59,8
71,2
COP
3,24
3,1
3,24
3,2
3,13
3,19
3,06
(2)
Electrical data
Voltage
400V/3 Ph/50Hz
Refrigerant circuit
Number of compressors/Number of circuits
Capacity steps
2/2
2/2
3/2
3/2
3/2
4/2
4/2
2x
11300
2x
11000
22700+
18100
22700+
18100
2x
22700
28600+
28600
36000+
36000
83,2
83,6
82,0
82,9
87,4
87,5
90,0
81,7
81,8
78,3
78,6
81,2
80,5
84,0
m3/h
Acoustic data
Sound powel level (1)
Outdoor blower outlet - Standard unit (Lw)
Sound powel level (1)
Outdoor blower outlet - Low noise unit (Lw)
dB(A)
(1)
Operating limits
SPLIT UNIT
Maximum outdoor temperature
Cooling mode
Minimum outdoor temperature
Cooling mode (1)
Minimum outdoor temperature
Heating mode
72
GC15-E_V1
020
025
030
035
040
045
055
070
085
100
120
140
45
45
45
45
45
47
47
47
47
47
47
47
AIRCOOLAIR
Operating limits
CONDENSING UNIT
020 025 030 035 040 045 055 070 085 100 120 140 200 230
45
45
45
47
47
45
45
47
47
47
47
47
47
47
+12C
+65C
+25C
Refrigerant connections
Split unit and condensing unit
20
S
AIRCOOLAIR
Total length 0 to 30m
25
S
30
S
Pipe sizes
Circuit 1
Liquid 1/2"
Pipe sizes
Circuit 2
Liquid
Gas
Gas 7/8"
35
S
40
S
45
D
55
D
70
D
5/8"
1" 1/8
1" 3/8
3/4"
1" 1/8
1" 3/8
5/8"
1" 1/8
7/8"
1" 5/8
2" 1/8
3/4"
1" 3/8
7/8"
1" 5/8
2" 1/8
16
65
18
20
S
ASC/ASH
A
B
C
Operating weight
1195
660
1375
kg 168
25
S
30
S
219
1195
980
1635
221
239
mm
(1)
35
S
40
S
258
45
D
55
D
70
D
452
1960
1195
1635
463
499
85
D
537
748
2250
1420
2155
828
932
2250
2300
2250
1684 1704
GC15-E_V1
73
AIRCOOLAIR
CIC/CIH
Air treatment section
Split indoor unit
CIC/CIH
A
B
C
Operating weight
20
S
25
S
108
1195
840
645
111
mm
(1)
kg
30
S
115
35
S
40
S
150
1445
960
735
160
45
D
170
55
D
70
D
242
2250
960
735
259
85
D
276
100
D
120
D
140
D
470
2900
1140
1140
480
490
CIC/CIH
Free cooling module
CMC/CMH
A
B
C
Operating weight
20
S
25
S
50
1195
674
645
50
mm
(1)
kg
30
S
50
35
S
40
S
75
1445
697
740
75
45
D
75
70
D
165
2250
1150
740
165
85
D
165
100
D
120
D
140
D
190
2900
1150
1140
190
190
Principle sketches
With exhaust fan
Sizes 020E to 045D
With economizer
Sizes 020E to 045D
With economizer
Sizes 055D to 140D
Fresh air
Return air
Exhaust air
Supply air
74
GC15-E_V1
AIRCOOLAIR
Options
Fresh air
Free cooling: The use of an
economizer is the most efficient
way to reduce ruining costs by using
fresh air when appropriate.
Fresh air management: The
economizer is able to ensure that
fresh air provided to the building
meets the Indoor Air Quality
requirement.
Exhaust fan module: this ensures
overpressure extraction in case of
high level of fresh air inlet.
Return module: the return fan
enables to overcome the return duct
pressure drop, particularly during
freecooling operation.
Indoor air quality
EU4 / F7 panel filters: Set of G4
prefilter and F7 filter at return,
operating on return air and fresh air.
Adding a G4 pre-filter before the F7
filter reduces excessive replacement
of F7 filters.
Dirty filter sensor: A differential
pressure sensor measures the
pressure drop across the filters and
coil to allow preventive filter change,
thus reducing energy consumption
and improving air quality.
Indoor air quality sensor: This
feature gives the possibility to match
minimum fresh air requirements
with occupancy. It measures CO2
levels and adjusts fresh airflow rate
accordingly.
Auxiliary heating
Electrical heater: Standard, medium
and high capacity heaters. Available
with steps or modulating control.
Hot water coil heater: includes
the valves and has a proportional
potential with CLIMATIC advanced
control.
Control
eDrive, direct transmission on
return fan and supply fan : variable
speed fans adjust airflow rate to the
exact needs and during unoccupied
period. This feature saves up to
30% annual energy consumption and
reduces maintenance costs.
Smoke detector: The optical head of
the smoke detector can detect any
type of smoke. When this occurs the
unit will stop operating, the return air
damper will close fully and the fresh
air damper will open fully
Refrigerant options
Winter cooling operation down to
0C.
Winter cooling operation down to
-15C.
Long refrigerant piping: allows up
to 65 m piping between the internal
and external units.
Shut off service valve: facilitate
installation & service operations.
Includes a valve on the gas loop side
and a valve on the liquid loop side of
split units.
Refrigerant pre-charged: split
condenser supplied with factory filled
refrigerant pre-charge. Includes shut
off service valves, on liquid & gas
loop sides.
Electrical & safety
Main switch: located on the electrical
panel of the condensing unit. The unit
device turns off when the board
panel is opened.
Phase sequencer: this device
prevents the compressor from
starting if the phases are reversed.
Other options
Low noise: Reduce radiated noise
and noise in duct at condenser.
Precoated coil: outdoor or indoor
coils anticorrosion treatment.
Particularly recommended in salin
or polluted environments.
Coil protection grill: It prevents
condenser coil against accidental
impacts.
High pressure 250 Pa FP1:Available
static pressure for outdoor unit up
to 250 Pa.
Rubber anti-vibration mounts: To
avoid transmission of vibrations for
the floor where the unit is installed
while unit is operating.
Soft star ter (400V/3): This
electronic element reduce the
starting current up to 40%.
M0 fire proof insulation : This
insulation will not burn and will not
generate smoke in case of fire.
GC15-E_V1
75
ASC/ASH
AIRCOOLAIR
CMC/CMH
COMPACTAIR
Option
FMC/FMH
Standard equipment
FLATAIR
Refrigerant
Pressure transducers
Shrader valves on facade
Scroll/MultiScroll
Tandem
Compressors
(1)
Expansion valves
(1)
Condenser fans
Economiser
Motorised free-cooling/heating 2 damper
Main disconnect switch
Casing
Insulation
M0 fire-proof
Air filter
EU4
EU4 + F7
Blue fin coated coil protection for outdoor coil
Anti-corrosion protection
Blue fin coated coil protection for indoor and outdoor coil
Horizontal supply
Air flow configuration
Up supply
Horizontal return
76
GC15-E_V1
Exhaust
ASC/ASH
AIRCOOLAIR
CMC/CMH
COMPACTAIR
FMC/FMH
FLATAIR
Exhaust fan
CLIMATIC 40
CLIMATIC 60
Regulation on ambiant temperature
7 time zones per day with 4 different operating modes
4 time zones per day with 1 operating mode each
Dirty filter alarm sensor
Alternate defrost
(1)
Morning anticipation
Dynamic setpoint
eFlow airflow rate on DS display
Airflow management of variable condenser fan
Intelligent fresh air management (Patent 03 50616)
Reading of suction pressure on DS display
Control and
communication
Additional control
and safety
CO2 control
Humidity control
3 phase detector
GC15-E_V1
77
Chillers &
heat pumps
Combined heat
recovery system
Air cooled
condensers
Dry-coolers
78
GC15-E_V1
&
80
86
90
96
102
106
108
Dry cooler
FC/FI NEOSTAR
20 1200 kW
110
112
114
GC15-E_V1
79
ECOLEAN
20 200 kW
Main applications
Small size office buildings
Residential buildings
Hotels
Hospitals
Industry
General description
The ECOLEAN range offers an optimal solution to all air
conditioning applications in light commercial and retail
applications (offices, shops, restaurants) or applications
in the industry.
This range is designed with the latest technologies to ensure
high energy performance all along the year thanks to R410A
multi scroll compressors, optimized heat exchange surface
area associated with eDrive variable speed pump (optional).
LENNOX has designed ECOLEAN targeting the lowest
market noise level. This has been achieved by research
and development innovations on fan blade technologies and
noiseless compressor montage. ECOLEAN is achieving the
best market acoustic performance thanks to the use of the
latest generation of OWLET fans associated with acoustic
compressor enclosure.
GC15-E_V1
Main components
Galvanized sheet steel framework with fork lift pockets
Water filter
version
Flow switch
Advanced control
CLIMATIC microprocessor based control is providing the
following functions:
7 scheduling time zones per day to allow energy
consumption and sound level management.
PI control of the water temperature with operating time
equalization of the compressors.
Water set-point offset based on outdoor air
temperature.
Noise setting capability per time zone (Auto mode, Auto
Quiet mode or Quiet mode).
Compressor anti short-cycling management.
Dynamic defrost.
Automatic compressor unloading in case of excessive
condensing pressure.
Water pump control with operating time equalization
and automatic change-over in case of a pump fault.
Variable water flow pump control to reduce annual
pumping energy consumption.
Master/slave or cascade control of 2, up to 8 chillers
operating in parallel with operating time equalization and
automatic change-over in case of a unit fault.
Options
Epoxy coated aluminium fins coils treated
Soft starter
Three phase protection
Electronic flow switch
Evaporator antifreeze protection
Tank antifreeze heater
Water tank electrical heater
temperature
interface
supervision
DC advanced display
DC remote customer display 24V (supplied loose)
Non contractual photos
81
ECOLEAN
General data - Standard version
EAC/EAR
251
291
351
431
472
552
672
812
22,1
25,9
32,0
37,6
44,1
50,7
63,4
75,4
Cooling mode
Cooling capacity
EER
kW
(1)
(1)
ESEER
(2)
2,9
2,85
2,86
2,81
2,9
2,79
2,83
2,82
3,27
3,26
3,26
3,18
3,91
3,87
3,86
3,96
23,6
27,6
33,6
37,8
47,8
54,7
68,0
75,7
3,0
3,0
3,0
2,91
3,0
2,94
3,0
2,92
Heating mode
Heating capacity
COP
kW
(1)
(1)
Electrical data
Voltage
Refrigeration circuit
Refrigerant type
R410A
Number of compressors
2
Brazed plate heat exchanger
Evaporator type
Capacity steps
kg
5,5/
5,8
6,11/
6,5
8/
8,7
9/
10
11/
11,4
12,2/
12,7
16,1/
16,8
18,5/
19,3
m3/h
3,8
4,45
5,5
6,47
7,59
8,72
10,9
12,98
51
54
30
34
32
34
40
47
69
78
60
73
50
57
71
87
Pressure drop
Nominal water flow
Pressure drop without water filter
kPa
Hydraulic connection
Type
Threaded - Female
Diameter
1 1/2"
2"
Acoustic data
Sound power level /Sound pressure level
(3)
LN (4)
STD
dB(A)
71/40
70/39
71/40
72/41
74/43
73/42
74/43
75/44
76/44
76/44
77/45
78/46
79/47
79/47
80/48
81/49
+48
-15
C
+22
-10 (option)/
+5 (standard)
+23
-12
C
+43
-
(3) Sound power level and sound pressure level at 10 m from the unit, in free
filed, conformity with ISO3744 norm
(4) Maximum sound power level only if "Quiet" mode is selected. If "Auto Quiet"
mode is selected, the unit may operate the high fan speed to work at
full load and avoid compressor unloading in case of very high or very low
ambient temperatures.
82
GC15-E_V1
ECOLEAN
General data - Standard version
EAC/EAR
1003
1103
1203
1303
1403
1604
1804
2104
88,2
102
112
126
139
149
174
199
Cooling mode
Cooling capacity
EER
kW
(1)
(1)
ESEER
(2)
2,83
2,9
2,79
2,86
2,87
2,76
2,9
2,8
4,19
3,97
3,83
3,87
3,98
4,02
3,98
3,76
95
108
118
130
143
159
180
205
3,05
2,92
2,97
2,95
2,85
Heating mode
Heating capacity
COP
kW
(1)
(1)
Electrical data
Voltage
Refrigeration circuit
Refrigerant type
R410A
Number of compressors
4
Brazed plate heat exchanger
Evaporator type
Capacity steps
kg
23,5/
23,3
26/
28
27/
29,5
30/
32,2
33,7/
35,5
36,2/
40
45/
52
47/
54
m3/h
15,2
17,6
19,2
21,6
23,9
25,7
29,9
34,2
35
34
40
48
48
43
48
64
43
47
57
69
76
61
73
95
Pressure drop
Nominal water flow
Pressure drop without water filter
kPa
Hydraulic connection
Type
Threaded - Female
Flange
2 1/2"
3"
Diameter
Acoustic data
SLN (4)
Sound power level /Sound pressure level
(3)
72/40
75/43
76/44
78/46
78/46
76/44
77/45
80/48
(4)
dB(A) 75/43
76/44
79/47
81/49
81/49
78/46
81/49
83/51
STD
80/48
82/50
85/53
87/55
87/55
85/53
87/55
90/57
LN
+48
-15
+22
-10 (option)/
+5 (standard)
+23
-12
C
+43
(3) Sound power level and sound pressure level at 10 m from the unit, in free
filed, conformity with ISO3744 norm
(4) Maximum sound power level only if "Quiet" mode is selected. If "Auto Quiet"
mode is selected, the unit may operate the high fan speed to work at
full load and avoid compressor unloading in case of very high or very low
ambient temperatures.
GC15-E_V1
83
ECOLEAN
General data - Integrated hydraulic module
ECOLEAN HY / HN
251
291
351
431
472
552
672
812
m3/h
3,8
4,45
5,5
6,62
7,59
8,72
10,9
12,98
kPa
131
106
150
96
128
115
165
107
Pump module
Nominal water flow
Available static pressure
Voltage
Absorbed power
kW
0,72
1,17
1,55
12
18
Bar
Weight
kg
Buffer tank
1,1
l
16
17
23
24
(1)
Volume
75
Weight
kg
31
100
32
2,25
kW
ECOLEAN HY / HN
Pump module
33
12
m3/h 15,17
kPa
186
17,61
19,23
176
155
Voltage
21,62
23,87
25,66
29,93
34,23
132
119
116
140
176
3,7
Absorbed power
kW
2,93
35
50
Bar
Weight (EAC/EAR)
Buffer tank
2,45
kg
26
29
74
92/97
(1)
Volume
240
350
Weight
kg
55
70
8,25
24
36
13
T
12
14
14
8
P 7 P
13
T
12
12
P14
5
13
T
2
12
3
10
1
11
12
10
12
6 Expansion vessel
11 Drain valve
2 Water tank
7 Water pump
4 Safety valve
5 Manometer
84
P14
GC15-E_V1
10 Flow switch
ECOLEAN
EAC/EAR
251
291
A
B
351
431
472
552
672
1195
1960
980
1195
mm
812
1375
Standard version
241
260
260
260
241
260
260
260
248
248
248
248
248
248
248
248
243
251
271
300
480
492
534
578
258
266
286
315
510
522
564
608
Standard version
Operating weight
kg
(1)
(2)
kg
(2)
EAC/EAR
16
17
23
24
47
48
55
57
A
B
C
mm
1420
2300
1855
1954
Standard version
273
312
Standard version
Operating weight
663
831
964
1016
1045
1347
1703
1723
703
871
1004
1056
1085
1387
1783
1803
26
29
74
92/97
81
84
144
162/167
kg
(1)
(2)
(2)
kg
GC15-E_V1
85
AQUA4
50 320 kW
Main applications
Small and medium size office buildings
Hotels
Hospitals
Administration
needs
General description
The AQUA4 range is an air-cooled polyvalent heat pump unit
designed for 2 or 4 pipes applications. The AQUA4 unit is a
unique concept to reduce our environmental footprint, while
conserving and optimizing energy consumption.
AQUA4 P is a 4 pipes unit designed for more thermal
comfort with less energy consumption. The polyvalent heat
pump AQUA4 P units are developed to meet the requirements
of simultaneous and independent cooling and heating needs,
in the most efficient way.
Main components
R410A refrigerant
Two refrigerant circuits
Galvanized steel base frame powder coated (grey)
Galvanized steel cabinet powder coated panels (white)
Main disconnect switch with lock
Ventilated electrical control panel
High efficiency scroll compressors mounted in a closed
technical box
coating
Advanced display
Scheduling
Defrost system independent of each circuit
Water set-point offset based on outdoor air temperature.
Operating time equalisation of the compressors and
pumps
- Master/slave or cascade control.
Others components :
- Filter driers molecular sieve
- Liquid moisture indicator
- Tanks and liquid separators with marking complies with
EEC Directive 97/23 PED
- High and low pressure switch
- Solenoid valves
- Schrader valves
86
GC15-E_V1
4 pipes system
Quieter unit
-8 dB(A) noise level reduction vs traditional heat pump
in standard (S version)
Up to -12dB(A) noise level reduction with low noise unit
(L version)
Innovative hybrid structure of fan blades
Unique sound proof cabinet enclosing all components to
reduce radiated sound levels
Simultaneous or independant
demands for heating and cooling.
2 pipes system
Options
Hydraulic module with low pressure or high pressure
interface
Accessories
Power factor correction
Soft starter
Victaulic coupling parts (x4)
External temperture sensor for setpoint offset
Pressure gauges lp / hp
Filter dryer maintenance kit
Lifting tubes (x2)
Coils protection guards
Water filters (x2) (supply loose)
GC15-E_V1
87
AQUA4
General data
AAH
041 051 061 071 081 094 104 124 144 164 194 214 244 274 294 324
kW
50
54
65
71
81
98
107
129
142
162
181
216
236
259
296
314
EER
3,1
3,0
3,2
3,1
3,1
3,0
2,9
3,0
2,9
3,0
2,7
2,9
2,8
2,8
2,9
2,7
ESEER
4,1
4,1
4,2
4,2
4,1
4,5
4,6
4,0
4,1
4,2
4,3
4,4
4,2
4,2
4,3
4,3
Water flow
m3/h 8,53 9,31 11,16 12,25 13,95 16,89 18,46 22,22 24,42 27,77 30,99 37,14 40,57 44,48 50,84 53,93
kPa
27
31
32
38
31
34
40
42
51
46
41
57
57
38
47
63
kW 51,9 57,2 67,9 74,5 84,6 102,8 113,5 135,7 150 170,4 194,9 229,4 253,5 279,9 316,6 340,8
COP
3,24 3,21 3,26 3,21 3,24 3,22 3,20 3,04 3,02 3,08 3,05 3,13 3,23 3,20 3,25 3,14
Water flow
m3/h 9,02 9,95 11,81 12,95 14,63 17,86 19,73 23,56 26,07 29,61 33,87 39,86 44,05 48,64 54,67 59,23
kPa
30
36
36
43
35
39
47
47
58
53
49
66
66
54
66
76
48,9 53,9 63,6 70,3 82,3 97,9 107,9 125,9 139,2 160,3 184,3 217,9 243,3 263,4 301,5 326,6
kW
Heating capacity
63,3
7,43 7,33 7,54 7,43 7,70 7,44 7,31 7,44 7,35 7,47 7,33 7,44 7,56 7,49 7,61 7,40
70
81,9 90,9 105,5 126,7 140 162,8 180,6 207 239,2 281,8 313,1 340 387,6 422,7
Electrical data
Power supply
Refrigeration circuit
Number of circuits
Victaulic
Diameter In/Out
2''
2''1/2
3''
4''
l 200
200
220
220
220
340
340
600
600
600
600
600
600
765
765
765
80
80
81
81
81
82
82
84
84
85
85
86
86
86
87
87
52
52
53
53
53
54
54
56
56
57
57
58
58
58
59
59
73
73
75
75
75
77
77
79
80
80
80
82
82
82
83
83
45
45
47
47
47
49
49
51
52
52
52
54
54
54
55
55
Acoustic data
Sound power level Lw
(S version)
Sound pressure level Lp
(S version)
(1)
db(A)
(1)
GC15-E_V1
AQUA4
Dimensions and weights
A
B
AAH
041
051
061
071
081
094
104
124
2510
2510
2862
2862
2862
3610
3610
3610
1183
1183
1183
1183
1183
1183
1183
1654
1735
1735
1735
1735
1735
1679
1679
1679
680
690
800
810
850
1190
1210
1530
144
164
194
214
244
274
294
324
3610
3610
3610
3610
3610
4276
4276
4276
1654
1654
1654
1654
1654
1654
1654
1654
1846
1846
1846
2330
2330
2330
2330
2330
1550
1690
1710
1890
1910
2260
2290
2320
mm
C
Weight
kg
AAH
A
B
mm
C
Weight
kg
AAH 324 PS
GC15-E_V1
89
NEOSYS
200 1000 kW
Main applications
Medium and large size office buildings
Hotels
Hospitals
Industry
eDrive
Reduced total cost of ownership
3-year warranty*
General description
The NEOSYS unit is designed to be integrated into urban or
residential environments.
As main characteristics the NEOSYS unit offers state of the
art design to match architectural constraints and adjustable
sound level performances during day and night to satisfy local
environmental constraints.
The Active Acoustic Attenuation System automatically adjusts
the airflow of the owlet variable speed fans according to the
building load while complying with the permitted sound level. It
also enables floating condensing pressure management. The
noise level is programed and set by time slot and then the
performance or required noise level mode is chosen.
This range is also proposed with a compact hydraulic module.
Depending on the nature of the hydraulic installation, NEOSYS
can be fitted with the choice of a pump providing 150 or
250 kPa external static pressure. To facilitate start-up, you
can choose a classical hydraulic module with manual water
flow control valve or, as an option, an electronic control, that
will adjust the water flow to the actual requirements of the
installation (optional eDrive).
NEOSYS NAC:
NEOSYS NAH:
Heat-Pump version
Heating capacity: 200 to 500 kW
The NEOSYS liquid chiller and heat pump range offers four
options for energy savings :
eDrive, variable speed pump technology : the water flow
in the chiller is electronically adjusted and different types
of control are available.
Free Cooling : fully integrated option in the unit, is directly
controlled by the products control system to maximize the
use of free cooling of outside air.
Partial heat recovery : integrated desuperheater recovers
heat for the production of free hot water up to 70C
simultaneously with chilled or hot water production.
Total heat recovery (THR) : this packaged option is able
to produce free hot water with maximum performance
and efficiency whatever the ambient conditions are. This
packaged option optimizes energy consumption thanks
to high Total Energy Ratio values and very low refrigerant
charge.
Versions
STANDARD VERSION: Basic version with single speed fan and step fan control, no side grille and no side panel
* 3-year warranty only applies to compressors, fans, exchanger coils. Subject to LENNOX warranty policy and to maintenance contract by an accredited LENNOX company.
90
GC15-E_V1
Main components
Casing made of galvanised steel sheet metal painted with
height (= 2m)
version)
Options
Hydraulic module with low or
GC15-E_V1
91
NEOSYS
General data
NAC
200
230
270
300
340
380
420
480
208
236
273
308
351
387
430
490
2,89
2,75
2,56
2,88
2,80
2,60
2,82
2,81
4,24
4,03
3,99
4,04
4,15
3,90
4,19
4,01
Cooling mode
Cooling capacity
EER
kW
(1)
(2)
ESEER
(2)
Electrical data
Voltage
Refrigeration circuit
Number of circuits
Number of compressors
Capacity steps
Evaporator type
Condenser type
Pressure drop
Pressure drop
kPa
(1)
43
54
56
48
35
42
50
48
Hydraulic connections
Type
Victaulic
Diameter In/Out
4"
5"
Acoustic data
Global sound power level
(1)
dB(A)
(3)
(3)
89
89
89
91
91
91
92
92
57
57
58
59
59
59
61
61
82
83
84
85
86
86
87
87
51
52
54
54
55
55
56
56
43
46
46
Operating limits
Min. outlet water temperature
+5 (standard)/-10 (option)
20
3
C
8
+6 (standard)/-20 (option)
46
46
46
46
46
92
GC15-E_V1
NEOSYS
General data
NAC
540
600
640
680
760
840
960
1080
531
605
627
702
774
860
980
1062
2,63
2,76
2,77
2,80
2,60
2,82
2,81
2,63
4,0
4,15
4,17
4,15
3,90
4,19
4,01
4,0
Cooling mode
Cooling capacity (1)
EER
kW
(2)
ESEER
(2)
Electrical data
Voltage
Number of circuit
Number of compressors
10
12
Capacity steps
10
12
Refrigeration circuit
Evaporator type
Condenser type
Pressure drop
Pressure drop
kPa
(1)
56
59
58
57
51
56
66
71
Hydraulic connections
Type
Victaulic
Diameter In/Out
6"
8"
Acoustic data
Global sound power level
(1)
dB(A)
(3)
(3)
93
94
94
94
94
96
96
96
61
62
62
62
62
64
64
64
88
89
89
89
90
90
90
91
57
59
59
58
58
59
59
60
46
46
43
Operating limits
Min. outlet water temperature
+5 (standard)/-10 (option)
20
3
C
8
+6 (standard)/-20 (option)
43
46
46
46
43
GC15-E_V1
93
NEOSYS
General data
NAH
200
230
270
300
340
380
420
480
191
217
266
295
324
361
398
442
2,60
2,34
2,54
2,52
2,46
2,71
2,50
2,41
3,99
3,76
3,98
3,94
4,01
4,08
3,86
4,14
219
235
291
339
363
404
452
499
3,05
2,80
2,78
3,01
3,00
3,04
2,98
2,95
Cooling mode
Cooling capacity
EER
kW
(1)
(2)
ESEER
(2)
Heating mode
Heating capacity
COP
kW
(1)
(1)
Electrical data
Voltage
Refrigeration circuit
Number of circuit
Number of compressors
Capacity steps
Evaporator type
Pressure drop
Pressure drop
kPa
(1)
37
46
55
44
30
37
44
42
Hydraulic connections
Type
Victaulic
Diameter In/Out
4"
5"
Acoustic data
Global sound power level
(1)
dB(A)
(3)
(3)
89
89
91
91
91
92
92
92
57
57
59
59
59
61
61
61
82
83
85
85
86
87
87
87
51
52
54
54
55
56
56
56
Operating limits
Min. outlet water temperature
Cooling mode
+5 (standard)/-10 (option)
20
94
GC15-E_V1
+6 (standard)/-20 (option)
C
46
50
-12
(2) ESEER according to EN14511 Eurovent calcultaion method
(3) A3 system : Active Acoustic Attenuation system to automatically adjust the
air flow rate to respect night and day sound level constraints as standard
Check ongoing validity of certificate :
eurovent-certification.com
certiflash.com
Non contractual photos
05
04
02 Air purge
03 Pressure tap
02
04 Pump
05 Safety valve with manometer
06 Expansion vessel
03
07
01
03
09
10
NAC
200
230
270
300
340
380
420
480
3590
3590
3590
4620
4620
4620
5650
5650
2280
2280
2280
2280
2280
2280
2280
2280
2025
2025
2025
2025
2025
2025
2025
2025
1961
1989
2253
2643
2955
2997
3532
3604
1983
2011
2278
2676
3003
3045
3580
3661
NAC
540
600
640
680
760
840
960
1080
5650
6680
6680
9040
9040
11100
11100
11100
2280
2280
2280
2280
2280
2280
2280
2280
2025
2025
2025
1964
1964
1964
1964
1964
3655
4086
4105
6495
6564
7681
7806
7884
3712
4152
4175
6770
6854
7981
8141
8229
NAH
200
230
270
300
340
380
420
480
3590
3590
4620
4620
4620
5650
5650
5650
2280
A
B
mm
C
Shipping weight
Operating weight
kg
mm
C
Shipping weight
Operating weight
kg
mm
2280
2280
2280
2280
2280
2280
2280
2025
2025
2025
2025
2025
2025
2025
2025
Shipping weight
2154
2153
2881
3347
3301
3972
4020
4091
2176
2175
2906
3380
3349
4020
4066
4148
Operating weight
Non contractual photos
kg
GC15-E_V1
95
HYDROLEAN
20 165 kW
Main applications
Residential buildings
Small size office buildings
Hotels
Industry
Administration
General description
HYDROLEAN can be used for comfort air conditioning
requirements in offices, shops and hotels, and especially
when there are severe noise and dimensional constraints.
The HYDROLEAN range benefits from the latest technological
innovations such as scroll compressors, microprocessor
control and brazed plate exchanger. Compact unit, the
HYDROLEAN liquid chiller is easily installed in small spaces.
Since it is fully enclosed, it does not need a dedicated
machine room. One unit can be placed on top of another
for better use of space, if required (only for sizes 25 to 80).
96
GC15-E_V1
Main components
Advanced control
Microprocessor control
Front panel display
Control of refrigerant and water temperatures
General alarms with report
Time counter and run time equalization
Antifreeze protection
Remote ON/OFF
Connectable to a BMS
Options
Electrical equipment + control of outside fans
Remote display
GC15-E_V1
97
HYDROLEAN - SWC/SWH
General data
HYDROLEAN
025
035
050
070
080
25,8
37,9
50,8
71,9
83,6
4,37
4,25
4,26
3,89
3,77
4,78
4,59
5,40
5,13
4,80
25,5
37,6
50,3
71,6
81,8
4,01
3,89
3,92
3,56
3,68
4,57
4,48
5,48
4,60
4,62
28,0
41,4
55,5
79,6
91,7
3,73
3,73
3,68
3,51
3,62
kW
(1)
(2)
ESEER
(2)
kW
(1)
(2)
ESEER
(2)
kW
(1)
(2)
Electrical data
Voltage
Refrigeration circuit
Number of circuits
Number of compressors
SWC
kg
SWH
3,5
4,5
6,6
7,2
3,5
4,5
6,9
7,4
7,6
15,0
17,0
Hydraulic connections
Hydraulic connections type
Victaulic
Water inlet/outlet
Condenser
Condenser type
Water flow
m /h
3
Water volume
l
SWC
Pressure drop
SWH
kPa
5,3
7,8
10,4
3,0
4,0
5,2
5,7
5,7
21,6
26,9
33,6
56,9
71,4
17,6
25,0
31,3
59,0
73,6
600
Evaporator
Evaporator type
Water flow
m /h
4,4
6,5
8,6
12,6
14,4
3,0
4,0
5,2
5,7
5,7
kPa
16,5
20,5
25,4
41,4
52,9
Water volume
SWC
Pressure drop
SWH
600
Acoustic data
Global sound power level
(1)
(1)
dB(A)
69
71
72
74
75
61
62
64
65
65
98
GC15-E_V1
General data
HYDROLEAN
100
120
135
160
kW
(1)
(2)
ESEER
(2)
95,7
117,5
132,7
156,4
4,25
4,04
4,19
3,96
5,68
5,55
5,33
5,25
95,0
116,5
131,9
155,8
3,93
3,72
3,88
3,70
5,26
5,33
5,14
5,11
104,6
129,3
145,1
173,0
3,70
3,61
3,70
3,60
kW
(1)
(2)
ESEER
(2)
kW
(1)
(2)
Electrical data
Voltage
Refrigeration circuit
Number of circuits
Number of compressors
3
SWC
kg
SWH
6,3 + 5,7
6,4 + 5,7
7,6 + 7,5
7,5 + 8,0
6,5 + 5,8
6,5 + 5,8
7,8 + 7,7
7,7 + 8,2
Hydraulic connections
Hydraulic connections type
Victaulic
Water inlet/outlet
2" / DN50
Condenser
Condenser type
Water flow
m /h
3
Water volume
l
SWC
Pressure drop
SWH
kPa
19,5
24,1
26,9
32,8
10,0
10,0
12,8
12,8
30,3
48,1
42,7
58,6
30,3
45,3
39,8
58,6
600
Evaporator
Evaporator type
Water flow
m /h
16,5
20,6
22,7
28,0
10,0
10,0
12,8
12,8
24,7
34,5
31,6
41,7
22,6
31,3
29,0
40,9
Water volume
SWC
Pressure drop
SWH
kPa
600
Acoustic data
Global sound power level
(1)
(1)
dB(A)
75
76
79
81
66
66
71
73
GC15-E_V1
99
HYDROLEAN - SWR
General data
SWR
025
035
050
070
080
23,9
35,3
47,3
68,2
80,1
3,51
3,50
3,45
3,33
3,24
Cooling mode
Cooling capacity
EER
kW
(1)
(2)
Electrical data
Voltage
Refrigeration circuit
Number of circuit
Number of compressors
Capacity steps
kg
Nitrogen charge
Hydraulic connections
Hydraulic connections type
Threaded male
Discharge line
5/8''
Liquid line
7/8''
7/8''
1''1/8
1''3/8
Evaporator
Evaporator type
Water flow
m /h
3
Water volume
Pressure drop
kPa
4,1
6,1
8,2
11,8
13,8
3,0
4,0
5,2
5,7
5,7
12,0
16,0
20,0
37,0
48,3
600
Acoustic data
Global sound power level
(1)
(1)
dB(A)
SWR
69
71
72
74
75
61
62
64
65
65
100
120
135
160
89,4
110,9
124,2
148,2
3,52
3,43
3,46
3,39
Cooling mode
Cooling capacity
EER
kW
(1)
(2)
Electrical data
Voltage
Refrigeration Circuit
Number of circuit
Number of compressors
Capacity steps
kg
Nitrogen charge
Hydraulic connections
Hydraulic connections type
Victaulic
Discharge line
7/8'' - 5/8"
Liquid line
1''1/8 - 7/8"
7/8''
1'' 1/8
Evaporator
Evaporator type
Water flow
m /h
15,4
19,1
21,4
25,6
Water volume
10,0
10,0
12,8
12,8
Pressure drop
kPa
20,0
29,3
25,8
36,3
kPa
600
Acoustic data
Global sound power level
(1)
(1)
dB(A)
100
GC15-E_V1
75
76
79
81
66
66
71
73
Operating limits
SWC - SWH 025 > 160
Mini. evaporator outlet water temperature
+5 (standard)
-10 (option)
25
20
20
(1)
25
55
+5 (standard)
-10 (option)
25
C
20
35
62
HYDROLEAN
025
A
B
mm
035
050
070
080
100
502
645
802
1470
815
120
854
135
160
1705
SWC
Operating weight
Weight without water
kg
176
249
333
378
309
606
617
739
760
166
236
316
360
290
574
585
698
719
178
251
338
385
404
614
625
747
771
168
238
321
366
385
582
593
706
729
155
196
293
314
321
499
510
600
621
148
187
281
301
308
477
488
572
593
SWH
Operating weight
Weight without water
kg
SWR
Operating weight
Weight without water
Non contractual photos
kg
GC15-E_V1
101
MWC/MRC
180 720 kW
Main applications
Medium and large size office buildings
Hotels
Hospitals
Industry
General description
The MWC unit is designed for industrial and commercial applications where customers require reduced total cost of
ownership for new air conditioning equipment.
As main characteristics the MWC unit offers multi scroll R410A compressors with two circuits for safety operation and
oversized heat exchangers for high full and part load energy performances (ESEER > 6.0).
The MWC is the solution for indoor installation. Thanks to very compact dimensions and limited footprint MWC can be
installed easily into any technical room.
The MWC is available in 2 main versions to meet all customer requirements and applications:
MWC version is the water-cooled chiller. This version can be used for air conditioning applications in association with a
separate dry-cooler or using ground water. The MWC version can also be used for heating applications. With the hot
water set point control option, the MWC range can supply hot water up to +56C.
MRC version is the split version without condenser. This version can be used for air conditioning applications in association
with a remote air-cooled condenser.
The MWC and MRC are connectable with a remote dry cooler (FC NEOSTAR/FI NEOSTAR) or with a remote condenser
(NEOSTAR or MXW).
102
GC15-E_V1
Main components
2 independent circuits
R410A refrigerant.
Multiple scroll compressors.
Stainless steel brazed plate heat exchangers with true
dual circuit.
Thermostatic valve or electronic expansion valve (optional
from size 180 to 570, standard on size 650 & 720).
Moisture sight glass on the MRC version
Filter drier with removable cartridge filter.
Chassis made of galvanized steel sheet metal painted
with a grey powdered polyester paint.
Optional casing with removable panels made of galvanized
steel sheet metal painted with a grey powdered polyester
paint.
Unit electrical cabinet, components and wiring in
compliance with EN 60204-1 electrical directive.
400V/3/50 Hz power supply (without neutral) with a
single point of power connection.
IP24 protection class.
Main on/off switch mounted on the front panel.
CLIMATIC micro processor based control.
DC user interface mounted on the front panel.
Advanced control
CLIMATIC microprocessor based control is providing the
following functions:
Options
Control/Power electrical equipment of single evaporator
pump
pump
Control/Power electrical equipment of single condenser
pump
Control/Power electrical equipment of dual condenser
pump
Electronic expansion valve
Evaporator filter (supplied loose)
Condenser filter (supplied loose)
Evaporator flange connections (supplied loose)
Condenser flange connections (supplied loose)
Hot water set-point control (heat pump mode)
DC remote comfort display (supply loose)
DS service display (supply loose)
Modbus, LonWorks, BACnet communication interfaces
ADALINK II Supervision : customer friendly web based
supervision
Extension board for additional inputs/outputs
Anti-vibration mounts (supplied loose)
Panel enclosure (compressors)
GC15-E_V1
103
MWC/MRC
General data
MWC
180
230
280
330
380
450
510
570
650
720
kW
182
4,64
6,74
228
4,56
6,31
275
4,60
6,21
327
4,60
6,25
372
4,60
6,03
432
4,54
6,04
488
4,49
6,04
540
4,31
5,97
628
4,47
5,97
693
4,34
5,67
kW
196
4,05
246
4,00
297
4,06
351
4,05
401
4,05
468
4,02
530
3,98
601
4,02
681
4,01
750
3,89
29
6
6
31
30
Cooling mode
Cooling capacity
EER (2)
ESEER (2)
(1)
Heating mode
Heating capacity
COP (2)
(3)
Electrical data
Voltage
Refrigeration circuit
Number of circuit
Number of compressor
Capacity steps
Refrigerant charge per circuit
kg
4
8
5
12
4
6
14
5
14
4
22
Hydraulic connections
27
30
Victaulic
Water inlet/outlet
4"
Condenser
5"
Water flow
Water volume
Pressure drop
Water operating pressure
m3/h
l
kPa
33,8
13
38,6
42,4
24
32,1
51,1
35
25,4
60,5
35
34,8
69,1
43
33,7
80,6
52
36,4
91,2
56
42,6
103,7
61
51,1
117,4
77
28,4
129,1
77
34,0
600
Evaporator
m3/h
l
kPa
31,3
13
34,9
39,2
24
28,9
47,3
24
40,7
56,2
35
31,5
63,9
35
40,2
74,2
43
40,4
83,9
43
50,5
92,8
61
46,0
107,9
61
57,7
119
61
50,0
600
Acoustic data
Global sound power level (1)
Global sound power level with panel enclosure
option (1)
dB(A)
MRC
Cooling mode
Cooling capacity
EER (2)
(1)
kW
82
87
89
91
92
93
93
94
96
98
71
78
81
83
84
85
85
86
87
88
180
230
280
330
380
450
510
570
650
720
161
3,24
202
3,21
242
3,18
289
3,23
329
3,20
382
3,18
433
3,16
494
3,21
555
3,15
615
3,10
Electrical data
Voltage
Refrigeration circuit
2
Number of circuit
Number of compressor
Capacity steps
4
6
Hydraulic connections
Victaulic
1" 3/8 1" 1/8
1"1/8
1" 1/8 7/8"
7/8"
Discharge line
Liquid line
Evaporator
Water flow
Water volume
Pressure drop
Water operating pressure
6
6
2 x 1" 3/8
2 x 1" 5/8
2 x 1" 1/8
2 x 1" 3/8
2" 1/82x
1" 5/8 2" 1/8
1" 5/8 - 2 x 1"
1" 3/8
5/8
26,8
13
148,3
22,3
24
186,3
31,0
24
223,3
24,1
35
266,4
30,6
30,7
35
43
303,3 352,6
600
82
87
89
91
92
71
78
81
83
84
31,3
43
399,9
35,0
61
456,5
43,6
61
512,2
53,2
61
568,0
93
93
94
96
98
85
85
86
87
88
Acoustic data
Global sound power level (1)
Global sound power level with panel enclosure
option (1)
dB(A)
104
GC15-E_V1
Operating limits
MWC
180 > 720
MWC
MRC
180 > 720
-10
20
3
8
20
25
56
62
MWC/MRC
180
230
A
B
mm
280
330
380
450
510
570
820
1200
2150
2200
1645
650
720
1870
MWC
Footprint
Operating weight
Weight without water
m
kg
1,8
2,6
756
974
1158
1328
1534
1984
2100
2240
2440
2480
736
914
1088
1248
1444
1894
1990
2110
2270
2310
MRC
Footprint
Operating weight
Weight without water
m
kg
1,8
2,6
650
810
950
1120
1290
1660
1740
1870
1980
2020
620
770
910
1080
1240
1620
1690
1790
1890
1930
GC15-E_V1
105
ECOLEAN
EAC/EAR
Option
NEOSYS
NAC/NAH
AQUA4
AAH
R410A
Refrigerant circuit
Compressor
Low noise
Super low noise
Expansion valve
Thermostatic
Electronic
Axial fan
Variable control of condensation : HP floating
Fans
EC fan
Fan static pressure
Standard copper tube/aluminum fin
Air coil
(1)
(2)
Heat exchanger
Electrical
Softstarter
Water tank electrical heater (heat pump)
Power factor correction
Energy meter
Paddle flow switch
Electronic flow switch
Water filter
Flange connection
Water tank
Hydraulic module
Control and
communication
Energy saving
Miscellaneous
Packing
106
GC15-E_V1
MWC
MWC/MWR
R410A
Refrigerant circuit
Compressor
Expansion valves
Multiscroll
Low noise
Thermostatic
Electronic
Main disconnect switch
Control & power equipment single evaporator pump
Control & power equipment dual evaporator pump
Electrical
Hydraulic options
Control and
communication
Miscellaneous
GC15-E_V1
107
SRC
Combined heat recovery system
50 220 kW
Common product to
airconditioning and refrigeration
applications
Main applications
Small and medium sizes supermarkets
Convenience stores
installation
General description
The combined energy recovery system is a Plug and Play
solution, developed by LENNOX/HEATCRAFT.
In most cases, buildings equipped with food refrigeration
systems waste heat outside through air cooled condensers.
The SRC allows to recover thermal energy rejected by
the commercial refrigeration to heat the sales area, thus
achieving significant energy savings over the annual heating
consumption.
The SRC unit is equipped with a multi-tubular dual circuit
exchanger using the cooling capacity available due to the
closure of furniture which refreshed indirectly the sales floor
in open mode, to cool it.
The return on investment depends on the type of building,
installation, climatic conditions and energy costs at the
place of installation.
The SRC solution is composed of two ranges (12 models) :
"REMODEL" range and "NEW INSTALLATION" range
The "REMODEL" range is designed for existing installations :
It is designed to suit new thermal loads in an existing building
(installation of doors on refrigerated display cabinets).
Heat recovery provides energy saving on winter heating
consumption while using the cooling capacity excess available
of the cold production plant for the refreshment in summer.
The NEW INSTALLATION range is designed for new
buildings, buildings undergoing complete remodel or major
extension with replacement of the complete refrigeration
systems : This range takes into account the cooling and
heating needs (central sizing). The energy gains realized
during the heating season (heat recovery) are used to
finance a portion of the facility and ensure no extra cost to
refresh the sales area.
108
GC15-E_V1
Main components
Multi-tubular heat exchanger with an isolated bi-circuit,
Advanced control
3 control modes that can be selected through a three-
R404A
SRC
R134A
85/60
50
85
110
145
165
190
37
60
80
100
115
130
m3/h
10,8
18,7
23,9
31,5
35,8
41,2
kPa
11
17
15
30
29
27
50
80
105
140
160
180
30
50
65
85
95
105
kW
Heating capacity
Condenser (1)
Cooling capacity
Evaporator (2)
kW
m3/h
10,7
17,8
22,7
30,2
34,3
39,0
kPa
10
16
14
28
26
24
mCe
15
18
18
15
15
16
kW
10
10
12
50/40
Heating capacity
Condenser (1)
Cooling capacity
Evaporator (2)
R404A
SRC
80/85
Heating capacity
Condenser (1)
Cooling capacity
Evaporator (2)
kW
R134A
80
105
115
160
195
220
85
115
130
175
215
240
m3/h
15,5
20,8
22,9
31,2
38,4
42,8
kPa
28
17
24
26
29
65
85
95
130
160
180
70
95
105
140
170
190
Heating capacity
Condenser (1)
Cooling capacity
Evaporator (2)
kW
m3/h
12,6
16,6
18,4
24,6
30,0
33,3
kPa
18
11
15
17
18
mCe
15
16
17
16
16
16
kW
10
12
12
GC15-E_V1
109
FC/FI NEOSTAR
Dry cooler
20 1200 kW
Main applications
Air conditioning, free cooling...and cooling all kinds of fluids
General description
Casing:
Ventilation:
110
GC15-E_V1
Coil:
The dry coolers are equipped with coils with the following
characteristics :
- Copper tubes in a staggered arrangement and corrugated aluminium fins for optimum heat transfer.
- Headers with air vents and drain plugs.
- Connections: steel pipe, flanges.
Special coil coatings are available (Vinyl protection
(option BAE), Blygold Polual XT protection (BXT)) offering
greater corrosion resistance when used in aggressive
atmospheres.
Performances:
Nomenclature
F
I
(1)
(1)
(2)
(3)
PU
06
04
D5
(2)
(3)
(4)
(5)
(6)
(7)
(8)
FC
FI
Number of poles
(4)
(5)
Delta coupling
Star coupling
PN
Power Normal
PU
Power Ultra
Fans in line
SN
Silence Normal
Fans in parallel
SE
Silence Extra
(7)
Number of fans
SU
Silence Ultra
(8)
Type of module
Fan arrangement :
(6)
Options
Casing :
RAL Special colour
Coil :
MCI
Multi-circuits
BXT
BAE
Ventilation:
Motors equipped with overload thermostat.Recommended when the
MTH system could start very frequently (more than 30 starts per hour)
or when used with a speed controller
IRP
(1)
(1)
(1)
(1) :
MSK
Miscellaneous:
Surge tank
VEX
RT1
RT2
RT3
MEC
POWER
FC/FI NEOSTAR
Air temperature
SILENCE
PN
PU
FCH PU
FIH PU
SN
SE
SU
FCH SN
FIH SN
< 70 C
< 60 C
< 80 C
<70 C
< 80 C
< 80 C
< 80 C
Diameter
800
910
900
800
800
800
900
Number of poles
06P
06P
06P
08P
12P
16P
08P
Voltage
400V/3/50Hz
STAR (Y)
DELTA (D)
Class
RPM
880
885
910
680
430
330
687
Maxi W
2000
2480
2600
890
330
190
1230
Maxi A
4,30
5,15
5,50
2,22
0,86
0,39
3,00
dB(A)
80
88
80
71
62
55
74
RPM
670
685
738
540
255
540
Maxi W
1270
1570
1800
590
105
850
Maxi A
2,50
2,90
3,00
1,17
0,25
1,60
75
80
74
67
48
69
dB(A)
Non contractual photos
400V/3/50Hz
GC15-E_V1
111
NEOSTAR
18 1250 kW
Main applications
The air cooled condenser units of the NEOSTAR range are
General description
High-tech heat exchanger :
Ventilation :
Casing :
The casing is composed of galvanised sheet steel and prepainted galvanized metal, white colour.
The use of stainless steel screws guarantees excellent,
long-lasting corrosion resistance (standard ISO 7253) and
aesthetic quality.
All components used have successfully passed the salt mist
corrosion and Kesternich tests.
The units are delivered screwed to a wooden base.
112
GC15-E_V1
Nomenclature
PE
06
16
B3
SU
16
14
A2
(1)
(2)
(3)
(4)
(5)
(6)
(1)
PN
Power Normal
PU
Power Ultra
SN
Silence Normal
SE
Silence Extra
SU
Silence Ultra
(2)
(3)
Delta coupling
Star coupling
Fan arrangement :
(4)
Number of poles
Fans in line
Fans in parallel
(5)
Number of fans
(6)
Type of module
Options
Casing :
Coil :
RAL
Special colour
MCI
Multi-circuits
REH
BXT
RE2
BAE
RE3
RE4
ECB
Full crate
Ventilation :
RP2
RP3
MEC
IRP
C2V
SCU
(1)
(1)
(1)
(1) :
GC15-E_V1
113
MXW
50 1660 kW
Main applications
Refrigeration applications for outside installation.
Supermakets and food-processing industry
refrigerant charge
architectural integration
General description
The MXW range is optimized to minimize the footprint required
for installation by the combination of original design and innovative technology : the condenser is indeed built as modules
around W-shaped micro-channels coils for easy installation
in confined spaces.
Micro-channel coils allow a significant reduction of refrigerant
charge of condenser. The modular construction allows each
module to be connected independently offering autonomous
regulation of discharges of several compressorised racks. The
user may use one single condenser that reduces the space
requirement and installation time.
Casing :
Casing made of galvanised steel sheet metal painted with
a white powdered polyester paint.
Lateral anti-intrusive painted grilles with aesthetic design
(option)
Unit with attractive design and low height (< 2 meters) for
a perfect architectural integration
Coil :
The MXW range is equipped with aluminum micro channel
heat exchanger offering reliability and robustness (high
mechanical fin resistance) and high corrosion resistance.
This technology has proven its value in the automobile sector
and is now used for its numerous advantages in refrigeration
and air conditionning sectors.
These coils offer greater efficiency than traditional coils
(copper tubes/aluminum fins).Their reduced weight makes
them easier to handle.
As the coil is brazed in a single operation, the risk of leakage is considerably reduced and the quality inspections are
stringent: 100% of the products are tested.
Special coating for the coils is available to improve corrosion
resistance to aggressive atmospheres.
114
GC15-E_V1
Ventilation :
The MXW range is equipped with high reliability external
rotor fans.
AC MOTORS :
> 800 mm :
> 800 mm :
> 800 mm :
> 800 mm :
06P
08P
12P
16P
Nomenclature
MXW
06
04
(1)
(2)
(3)
(4)
(5)
(6)
(1)
(2)
(3)
(4)
Fan diameter :
Number of poles
800 mm
Delta coupling
(5)
Fan arrangement :
Star coupling
06
(6)
Fans in line
Number of fans
Options
Coil :
Casing :
ACR
MCI
Multi-circuits
G2F
BXT
BOE
Ventilation:
CMU Factory wired motors (AC motors)
IRP
RP2
RP3
CSC
Other options :
PAV
SilenTop option hides fans and acts as acoustic enclosure, ideal for urban
environment
GC15-E_V1
115
Airside products
116
GC15-E_V1
118
122
124
126
130
136
140
142
146
156
158
GC15-E_V1
117
ALLEGRA
Fan coil unit
0,6 6,7 kW
105 1500 m3/h
Main applications
Office buildings
Hotels
General description
9 sizes designed around 4 different versions, the extensive
range includes wall and ceiling mounted units, exposed or
concealed with centrifugal fan, delivering one of the most
versatile ranges of fan coils on the market today.
Range from 105 to 1500 m3/h including 9 flow rates (5
sizes with EC motor) and 4 models (wall- and ceiling-mounted,
with cabinet and concealed), each equipped with 3 or 4 row
coil and with the possibility to add a 1 or 2 row coil for 4-pipe
systems. It is the most comprehensive range, perfect to meet
all air-conditioning requirements of work environments like
offices, shops, restaurants and hotel rooms featuring ducted
installations with available pressure up to 40 Pa.
Main components
Cabinet : made of galvanized and pre-painted steel casing.
insulation
118
GC15-E_V1
General data
3-row coil - AC motor
ALLEGRA
100
Speed
400
500
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
0,59 0,86 1,03 0,91 1,25 1,56 1,57 1,78 2,39 1,73 2,14 2,87 2,03 2,94 3,64
kW
2 pipes
4 pipes (1 row)
0,47 0,71 0,86 0,69 0,97 1,24 1,15 1,32 1,80 1,28 1,60 2,19 1,51 2,23 2,82
0,76 1,15 1,39 1,12 1,59 2,02 1,87 2,15 2,92 2,09 2,61 3,56 2,42 3,59 4,50
0,63 0,89 1,04 0,94 1,25 1,52 1,59 1,77 2,26 1,73 2,06 2,65 2,07 2,83 3,42
Dp cooling
Dp heating
300
m3/h 105 175 220 145 220 295 235 270 385 265 335 485 315 495 650
Airflow rate
Heating capacity
200
2 pipes
0,9
1,7
2,3
2,5
4,4
6,5
KPa 0,8
1,4
2,0
2,1
3,7
5,5
9,4 13,8
0,7
1,3
1,7
1,7
2,8
4,0
5,2
6,3
9,7
6,0
2,8
3,9
16
25
33
14
22
32
20
25
41
21
28
44
22
39
61
dB(A)
23
30
36
21
31
38
27
31
40
24
30
38
22
32
39
4 pipes (1 row)
Fan
Sound pressure (*)
ALLEGRA
600
700
800
900
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
415
590
760
535
735
925
655
1020 1200
830
1210 1500
2,54
3,37
4,09
3,34
4,29
5,11
3,74
5,19
5,82
4,47
5,87
6,74
1,91
2,59
3,20
2,50
3,27
3,95
2,88
4,12
4,68
3,49
4,73
5,55
Speed
m3/h
Airflow rate
Heating capacity
kW
2 pipes
4 pipes (1 row)
Dp cooling
Dp heating
KPa
2 pipes
4 pipes (1 row)
Fan
Sound pressure (*)
3,07
4,13
5,09
4,01
5,19
6,27
4,80
6,74
7,66
5,71
7,72
9,06
2,5
3,19
3,81
3,29
4,09
4,79
3,6
4,86
5,41
4,22
5,46
6,23
8,6
14,1
19,8
16,2
25,1
34,2
8,7
15,5
19,0
11,9
19,3
24,6
7,3
12,0
16,8
13,8
21,3
29,1
7,4
13,2
16,2
10,1
16,4
20,9
3,2
4,9
6,7
4,3
6,3
8,3
5,0
8,5
10,3
6,7
10,5
13,2
37
55
78
54
79
103
62
105
130
92
134
176
dB(A)
28
37
43
33
42
47
36
47
51
41
49
55
200
Inverter power
Speed
Total cooling capacity
Dp heating
700
900
10
10
10
10
10
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
0,74 1,19 1,61 1,42 2,19 2,97 1,97 2,94 3,99 1,93 2,79 3,84 2,65 3,83 5,20
Dp cooling
600
m3/h 120 220 330 210 350 515 305 495 735 400 610 890 605 945 1395
Airflow rate
Heating capacity
400
kW
2 pipes
4 pipes (1 row)
0,56 0,93 1,30 1,04 1,65 2,28 1,47 2,23 3,11 2,65 3,56 4,63 3,40 4,62 5,98
0,92 1,53 2,13 1,70 2,70 3,74 2,35 3,59 4,95 3,08 4,47 6,09 4,45 6,41 8,69
0,81 1,23 1,63 1,47 2,11 2,74 2,0 2,80 3,68 2,65 3,56 4,63 3,40 4,62 5,98
2 pipes
4 pipes (1 row)
1,8
4,0
6,9
7,9 17,0 28,9 5,5 11,1 19,0 10,5 19,4 32,6 7,6 13,8 22,2
1,6
3,8
6,7
7,3 16,0 28,1 5,1 10,5 18,5 9,7 18,4 31,8 7,1 13,2 21,7
2 pipes
1,4
3,4
5,7
4 pipes (1 row)
1,3
2,6
4,3
4,5
2,8
KPa
4,5
2,9
4,9
7,8
4,6
7,8 12,3
W 7,0 11,0 20,5 6,5 12,0 25,0 7,5 15,0 32,0 9,0 18,5 41,0 16,0 41,0 99,0
Fan
dB(A)
21
32
42
21
33
42
24
35
45
28
39
48
35
46
55
Operating conditions :
Air inlet 27C DB/19C WB Chilled water 7/12C
Air inlet 20C - 2-pipe unit : hot water inlet = 50C 4-pipe unit : hot water = 70/60C
Standard connected speeds
MIN
(*)
Minimum speed
MED
Average speed
MAX
Maximum speed
The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation
time of 0.5 sec.
GC15-E_V1
119
ALLEGRA
4-row coil - AC motor - 2-pipe units
ALLEGRA
100
Speed
Airflow rate
200
300
400
500
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
m /h 105 175 220 145 220 295 235 270 385 265 335 485 315 495 650
3
0,67 1,02 1,23 1,01 1,43 1,81 1,65 1,89 2,57 1,83 2,28 3,12 2,19 3,25 4,09
kW 0,51 0,79 0,97 0,74 1,07 1,38 1,20 1,38 1,90 1,34 1,68 2,34 1,60 2,40 3,07
Heating capacity
0,82 1,27 1,55 1,18 1,72 2,20 1,94 2,23 3,07 2,16 2,72 3,76 2,53 3,81 4,83
Dp cooling
1,9
4,0
5,6
4,9
1,5
3,3
4,7
3,9
5,4
9,2
4,6
16
25
33
14
22
32
20
25
41
21
28
44
22
39
61
dB(A)
23
30
36
21
31
38
27
31
40
24
30
38
22
32
39
kPa
Dp heating
Fan
Sound pressure (*)
ALLEGRA
600
3
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
415
590
760
535
735
925
655
1020 1200
830
1210 1500
2,83
3,86
4,79
3,56
4,64
5,58
4,03
5,73
6,47
4,88
6,54
7,60
kW 2,07
2,86
3,60
2,62
3,47
4,23
3,04
4,43
5,06
3,72
5,11
6,05
3,39
4,69
5,88
4,20
5,55
6,71
5,06
7,36
8,43
6,22
8,53
10,1
14,4
24,8
36,2
12,5
20,0
27,7
7,6
14,1
17,5
10,6
17,8
23,2
11,0
19,5
29,3
10,3
16,9
23,7
6,2
11,4
14,5
8,7
14,8
19,3
37
55
78
54
79
103
62
105
130
92
134
176
dB(A)
28
37
43
33
42
47
36
47
51
41
49
55
Heating capacity
Dp cooling
kPa
Dp heating
Fan
Sound pressure (*)
900
m3/h
800
MIN
Speed
Airflow rate
700
200
Inverter power
Speed
400
600
700
900
10
10
10
10
10
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
m3/h 115 210 325 200 340 505 290 475 720 380 585 875 575 910 1365
Airflow rate
Total cooling capacity
0,78 1,33 1,88 1,44 2,28 3,19 2,06 3,20 4,54 2,62 3,84 5,34 3,61 5,25 7,14
kW 0,57 0,99 1,44 1,04 1,68 2,41 1,49 2,35 3,41 1,91 2,84 4,03 2,71 4,03 5,63
Heating capacity
0,94 1,63 2,37 1,70 2,75 3,91 2,43 3,87 5,60 3,09 4,61 6,51 4,50 6,70 9,39
Dp cooling
kPa
Dp heating
Fan
3,2
8,9 16,1 8,2 17,8 33,0 7,3 14,3 25,6 6,3 12,1 20,8
2,6
9,9 17,0
W 7,0 11,0 20,5 6,5 12,0 25,0 7,5 15,0 32,0 9,0 18,5 41,0 16,0 41,0 99,0
dB(A)
21
32
42
21
33
42
24
35
45
28
39
48
35
46
55
Operating conditions :
Air inlet 27C DB/19C WB Chilled water 7/12C
Air inlet 20C - 2-pipe unit : hot water inlet = 50C 4-pipe unit : hot water = 70/60C
Standard connected speeds
MIN
Minimum speed
(*)
120
MED
Average speed
MAX
Maximum speed
The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation
time of 0.5 sec.
GC15-E_V1
ALLEGRA
Dimensions and weights
Cased units
Chassis units
B
170
C
22
22
230
511
530
630
15 ext.
100
Condensate tray
(option)
12
29
12
100
ALLEGRA
100
200
300
400
500
600
700
800
900
675
775
990
990
1205
1205
1420
1420
1420
225
225
225
225
225
225
225
255
255
374
474
689
689
904
904
1119
1119
1119
218
218
218
218
218
218
218
248
248
205
205
205
205
205
205
205
235
235
220
220
220
220
220
220
220
220
220
480
480
480
480
480
480
585
585
585
220
220
220
220
220
220
220
220
220
4 rows
460
460
460
460
460
460
565
565
565
4 + 1 rows
11
14
19
20
23
24
26
31
32
mm
kg
Accessories
3-way or 2-way valve ON/OFF fitted
Electric heater with integral: safety thermostat and relay control
Extension condensate collection tray
Feet
Fresh air mixing damper (can be motorized)
Rear and Bottom closing panel(unit with cabinet)
Frame for wall concealed installation
Straight and 90 inlet and outlet flange
Air inlet grid with or without filter
Spigot plenum for return and discharge
Auxiliary drain pan
Condensat drain pump
GC15-E_V1
121
COMFAIR HD
High wall fan coils unit
1,2 4 kW
230 620 m3/h
Main applications
Office buildings
Residential buildings
comfort
up of the unit
General description
The consistent range with a tangential fan offers the maximum
acoustic comfort, with four different sizes in 2 pipes installation,
allows to regularly cover capacities going from 1.2 kW to 4.0 kW.
Main components
Tangential fan, designed to reach high capacities at low
122
GC15-E_V1
Control
Display, integrated in the cover cabinet, shows room
General data
COMFAIR HD
Speed
MIN
MED
MAX
MIN
MED
MAX
MED
MAX
MIN
MED
MAX
1550 1730 1960 1830 2100 2380 2420 2960 3340 2920 3640 4000
1170 1330 1520 1410 1640 1900 1890 2320 2680 2260 2850 3130
Water flow
l/h
266
297
336
314
359
409
415
508
573
501
625
686
kPa
10
12,5
15,9
14,3
18,3
22,9
9,7
11,3
14,8
11,8
17,8
21,6
Heating capacity
W 1880 2110 2420 2280 2610 2970 3000 3800 4390 3860 4450 4920
l/h
266
297
336
314
359
409
415
508
573
501
625
686
kPa
9,3
11,6
15
13
16,4
20,5
8,3
13,8
17,3
10,6
15,9
19,8
Heating capacity
W 3390 3810 4390 3850 4400 5030 5070 6450 7480 6540 7500 8280
l/h
298
334
386
338
386
442
445
566
657
574
659
727
kPa
10,9
13,8
18,4
14,1
17,7
22,4
8,8
16
21,1
13,1
16,9
21,2
m /h
234
282
344
273
333
417
375
476
553
426
544
620
47
50
53
45
50
54
43
50
54
45
52
56
38
41
45
37
41
45
34
41
45
37
44
48
db(A)
230V/50Hz
Power supply
Power input
Absorbed current
25
26
29
25
27
29
35
42
48
35
45
51
0,11
0,12
0,13
0,11
0,12
0,13
0,17
0,22
0,26
0,18
0,24
0,30
Water content
0,81
0,85
1,24
1,85
MIN
Sound pressure level: 8,6 dB(A) lower that the sound power level for a room of 90 m3 with a reverberation time of 0,5 sec.
Supported power supply: ~230V10%/1 Ph/50 Hz
COMFAIR HD
L
H
mm
P
Weight
kg
880
990
1172
1172
298
305
360
360
205
210
220
220
11,5
12,4
19
20,5
GC15-E_V1
123
COMFAIR HH/HV
High pressure fan coil unit
2,8 61 kW
840 8000 m3/h
Main applications
Small size commercial building
Offices buildings
Food and non food retail
Hotels
General description
Centrifugal high pressure fan coils available in 7 capacity sizes, vertical
(HV) or horizontal (HH) configuration, 2 and 4 pipe systems or 2 pipe
system with additional electric heater.
Standard configuration: 3 or 4 row coils for the 2 pipe system and 3 or
4 row coils + 1 or 2 row coils for the 4 pipe system.
Main components
Main structure in galvanized sheet metal, 1 mm thickness,
Auxiliary coil
C
124
GC15-E_V1
Rows
Connections
Rows
Connections
Nr
mm
Nr
mm
10
20
30
40
50
60
70
1/2"
1/2"
3/4"
3/4"
1"
1/2"
1/2"
1/2"
1/2"
3/4"
1"
1" 1/4
mm
20
20
20
20
20
20
20
mm
650
1000
1100
1339
1339
1341
2028
mm
533
533
533
533
533
853
853
mm
299
299
324
324
374
674
674
kg
28
36
41
46
57
117
192
General data
COMFAIR HH/HV
Speed
10
20
2 pipe system (3 row coil for HH/HV 10-50 - 4 row coil for HH/HV 60-70)
1
2,18
3,30
Sensible
2
2,20
4,10
3
2,30
4,34
(1)
Cooling capacity
1
2,83
4,50
Total
kW 2,90
2
5,30
3
3,09
5,60
1
3,60
5,30
Heating capacity (2)
2
3,70
6,31
3
3,97
6,70
Water flow
l/h 531
1051
1
13,1
17,2
Cooling
2
14,2
23,2
3
15,3
26,9
Water pressure drop
kPa
1
11,0
14,4
Heating
2
12,0
19,5
3
13,0
22,6
Standard
3
6
Electrical heater
kW
High
4,5
9
1
570
737
Airflow
m3/h 610
2
940
3
650
1064
1
54
51
Inlet + radiated
2
57
56
3
60
57
Sound power level (4)
dB(A)
1
58
55
Outlet
2
61
58
3
64
61
4 pipe system (3 +1 row coil for HH/HV 10-50 - 4+2 row coil for HH/HV 60-70)
1
2,38
3,45
Sensible
2
2,36
3,94
3
2,40
4,34
(1)
Cooling capacity
1
2,75
4,50
2
5,07
Total
kW 2,86
3
2,87
6,11
1
3,23
4,70
2
3,37
5,90
Heating capacity (3)
3
3,40
6,20
1051
Cooling
l/h (1) 494
Water flow
534
Heating
l/h (3) 292
1
13,4
15,0
2
14,8
19,0
Cooling
3
15,4
26,9
Water pressure drop
kPa
1
17,7
8,00
2
19,5
11,1
Heating
3
20,3
13,0
1
580
850
2
1014
Airflow
m3/h 631
3
654
1065
1
54
52
2
56
56
Inlet + radiated
3
60
57
(4)
Sound power level
dB(A)
1
58
55
2
60
60
Outlet
3
64
61
Available static pressure/Maximum external static pressure (50% performance reduction)
1
35
35
2
50
50
2 pipes system
3
60
60
Pa
1
35
35
2
50
50
4 pipes system
3
60
60
30
40
50
60
70
5,26
6,22
6,51
7,39
7,80
8,26
8,35
9,40
10,0
1531
22,2
22,5
31,4
18,5
19,7
26,1
6
9
1293
1627
1764
57
61
63
60
65
67
5,75
7,13
7,51
7,40
8,98
9,40
8,80
10,8
11,2
1616
16,5
25,3
27,8
13,9
21,2
23,3
9
12
1262
1728
1780
57
61
62
60
64
66
6,67
8,40
9,60
8,32
11,5
13,1
10,5
14,4
16,5
2253
13,3
20,8
26,0
11,2
17,6
22,0
9
12
1480
2163
2650
54
57
60
59
61
65
15,3
17,4
18,4
20,8
23,3
24,6
24,0
27,2
28,8
4231
21,1
25,3
27,7
17,4
20,5
22,6
12
18
3102
3645
3946
64
69
74
61
66
70
29,2
32,8
34,4
38,4
2,9
44,8
51,9
50,9
53,2
7705
28,0
27,2
29,3
18,6
22,4
23,9
18
24
6193
7248
7731
65
70
75
62
67
72
5,07
6,00
6,70
5,50
6,34
8,10
6,73
8,00
8,25
1394
710
19,9
22,0
31,5
21,0
29,0
23,7
1180
1461
1750
57
60
63
62
64
68
5,40
6,70
6,95
6,60
8,10
8,44
7,80
9,10
9,45
1451
814
21,7
25,9
37,9
9,50
11,4
15,9
1460
1700
2400
54
56
60
58
60
64
6,34
7,54
9,65
8,47
9,97
12,3
8,15
9,50
11,50
2116
990
13,2
17,5
25,8
12,4
16,3
23,0
1470
1860
2640
58
65
69
58
66
69
14,3
15,9
17,0
18,3
20,2
21,5
29,4
31,9
33,7
3698
2900
16,0
18,9
21,0
13,4
15,6
17,6
2905
3308
3623
64
69
74
61
66
70
26,7
30,1
32,0
33,3
37,3
39,5
52,8
58,1
61,0
6794
5246
52,8
58,1
61,0
14,8
17,7
19,6
5613
6570
7143
65
70
75
62
67
72
31
50
59
35
50
60
35
50
60
35
50
50
35
50
60
25
50
60
67
100
122
68
100
123
77
100
121
80
100
125
Data given at medium speed - 50 Pa available static pressure, except for sizes 60 & 70 : 100 Pa available static pressure.
(1) Cooling: Water inlet temperature: 7C; water outlet temperature: 12C; air inlet temperature: 27C D.B - 19C W.B
(2) Heating: Water inlet temperature: 50C; water flow rate as in cooling mode; air inlet temperature: 20C
(3) Heating: Water inlet temperature: 70C; water outlet temperature: 60C; air inlet temperature: 20C
(4) Sound power level: according to ISO 23741
GC15-E_V1
125
ARIA
1,6 7,2 kW
380 820 m3/h
Main applications
Office buildings
General description
The LENNOX ARIA fan coil unit is a horizontal ducted fan coil
unit for installations requiring medium and high static pressure.
It is available in 4 sizes : 2 pipes and 2 pipes with electric heater,
4 pipes.
The ARIA unit is a mono-block design including discharge and
return spigots and fresh air connection.
Main components
Galvanized steel main structure 10/10 mm thickness
(options)
2300 W)
damper
126
GC15-E_V1
General data
ARIA
10
20
30
40
m3/h
290
270
600
630
Pa
40
40
30
30
m3/h
385
360
810
825
Airflow
Available external static pressure
Pa
50
50
50
50
m3/h
490
455
1020
1065
Pa
65
65
70
75
1420
2080
3940
4680
1680
2580
4810
5710
1920
3040
5540
6810
1140
1540
3000
3460
1390
1940
3770
4280
1620
2330
4460
5210
244
357
677
836
289
443
826
1024
4
Cooling capacity
(1)
2
Total cooling capacity
Water flow
l/h
330
523
953
1227
20,1
11,9
17,9
18,0
27,1
17,6
25,8
26,1
34,5
23,7
33,4
36,4
1640
2240
4380
4990
1990
2850
5490
6190
2320
3430
6480
7550
142
194
379
447
172
246
475
557
201
297
561
681
6,4
3,4
5,4
5,0
9,0
5,2
8,1
7,4
12,0
7,3
11,0
10,8
1320
1380
2410
2927
1530
1610
2810
3460
1750
1850
3180
3937
113
121
211
277
134
141
245
328
153
161
278
374
1,6
1,7
6,7
14,3
2,0
2,2
8,8
19,4
2,6
2,9
11,1
24,6
197
196
403
407
51
50
56
53
55
54
62
58
58
57
64
61
kPa
4
Heating capacity 2 pipes
(2)
2
Heating capacity
Water flow
l/h
kPa
4
Heating capacity 4 pipes
(3)
2
Heating capacity
Water flow
l/h
kPa
4
Electrical data
230V/1Ph/50Hz
Acoustic data
2
Sound power level
Lw dB(A)
4
(1)
(2)
(3)
(4)
ARIA
A
B
mm
C
Weight
kg
10
20
30
40
886
886
886
886
233
233
233
233
428
428
728
1028
16
16
28
35
GC15-E_V1
127
ARIA EC
1,2 6 kW
300 850 m3/h
Main applications
Office buildings
General description
The LENNOX ARIA EC fan coil unit is a horizontal ducted fan
coil unit for installations requiring medium to high static pressure. ARIA EC is supplied with standard EC fan for low energy
consumption.
The LENNOX ARIA EC is available in 4 sizes : 2 pipes and 4 pipes.
The ARIA EC unit is monobloc and includes discharge and return
spigots together with fresh air connection.
Main components
Galvanized steel main structure 10/10 mm thickness
damper
128
GC15-E_V1
General data
Voltage
V (4)
ARIA EC
m /h
Pa
m3/h
Pa
m3/h
Pa
3
6
Airflow
Available external static pressure
8
10
Cooling capacity
10
20
30
40
265
19
385
40
445
47
265
21
385
40
445
50
500
20
680
40
820
50
620
20
850
40
910
46
1335
1680
1819
1063
1379
1520
230
288
313
18,1
27,1
31,4
2037
2701
2987
1507
2049
2291
350
464
514
11,7
19,2
23,0
3470
4284
4842
2616
3305
3806
596
737
833
14,2
20,9
26,1
4620
5825
6116
3412
4376
4617
795
997
1051
16,4
25,1
27,4
1523
1985
2184
132
171
189
5,7
9,0
10,7
2202
3003
3366
190
260
291
3,3
5,7
7,0
3800
4820
5538
329
416
425
4,1
6,4
8,3
4926
6335
6686
426
549
579
4,5
7,2
7,9
1242
1529
1655
109
134
145
1,4
2,0
2,3
1361
1684
1824
119
147
159
1,7
2,4
2,8
2160
2554
2828
189
223
247
5,5
7,4
8,9
2898
3520
3656
253
308
320
12,2
17,3
18,6
(1)
6
8
10
6
8
10
6
8
10
6
8
10
Water flow
l/h
kPa
(2)
6
8
10
6
8
10
6
8
10
Heating capacity
Water flow
l/h
kPa
(3)
6
8
10
6
8
10
6
8
10
Heating capacity
Water flow
l/h
kPa
Electrical data
230V/1Ph/50Hz
6
8
10
22
35
65
21
33
62
55
70
90
56
70
84
6
8
10
Lw dB(A)
49
53
58
49
53
58
56
60
63
53
55
59
Acoustic data
Sound power level
(1)
(2)
(3)
(4)
ARIA
A
B
mm
C
Weight
kg
10
20
30
40
886
886
886
886
233
233
233
233
428
428
728
1028
16
16
28
35
GC15-E_V1
129
ARMONIA
ARMONIA EC
Chilled water cassette
1,3 11 kW
Main applications
Samll size office buildings
Food and non food retail
General description
ARMONIA water cassettes cover any comfort air conditioning requirement and are available in :
STANDARD VERSION
7 capacity sizes for 2 pipe systems/2 pipes with additional electric
heater
11 capacity sizes for 4 pipe systems
EC VERSION
5 capacity sizes for 2 pipe systems/2 pipes with additional electric
heater
5 capacity sizes for 4 pipe systems
Both plastic and metallic diffusers have a very pleasant design and
have been designed to perfectly fit into 600 x 600 mm false ceiling standard modules.
Bigger sizes have 800 x 800 mm dimensions and grant the best sound level/capacity ratio.
To reply to any installation requirement, several possibilities are available : infrared remote control, stand alone controls and
master slave kit.
Codification example
Standard version
Basic unit
MB version
Basic unit with electronic board for Modbus, master/slaves, infrared and electronic remote
control
EH version
Basic unit with electric heater
EHMB version
Basic unit with electrical heater and electronic board for Modbus, master/slaves, infrared and
electronic remote control
EC version
Basic unit with EC fan
ECMB version
Basic unit with EC fan and electronic board for Modbus, master/slaves, infrared and electronic
remote control
ECMBEH version
Basic unit with EC fan, electrical heater and electronic board for Modbus, master/slaves,
infrared and electronic remote control
130
GC15-E_V1
Construction
Main casing is made of galvanised steel with inside closed cell polyethylene 10 mm thick thermal insulation and outside
anti-condensate lining.
Air diffuser available in ABS white colour and metallic white colour (up to size 320)
Air filter is washable, easily accessible and removable
Fan-motor assembly includes single inlet radial fan and 6 speed electric motor with single phase 230V/50 Hz supply,
In standard supplied wired in 3 speeds; but can be chosen among the 6 available and modified on site.
EC low energy consumption motor is also available. Thanks to inverter card continuous air flow/ heating/cooling variation
is allowed.
Heat exchangers are made of copper tubes and bonded aluminium fins. 2 pipe range are 1,2 or 3 rows while 4 pipe
4 pipe range has been especially designed to reply higher cooling (CWC 260-360-560-660) or higher heating (CWC 040-
Condensate pump with floating switch is supplied as standard and has 650 mm maximum head.
Main and auxiliary condensate drain pan are supplied as standard. Main drain pan is high density ABS polystyrene foam
Auxiliary drain pan is ABS and it is connected with the main drain pan to collect condensate of heat exchanger and control
valve(s).
GC15-E_V1
131
600 x 600
020
2-pipe version
Speed
m3/h
Airflow
Cooling capacity
Sensible cooling capacity
MAX
MIN
MED
MAX
MIN
MED
MAX
MIN
MED
MAX
310
420
610
310
420
520
320
500
710
430
610
880
1,63
1,98
1,84
2,34
2,68
2,25
3,34
4,33
2,94
3,88
5,02
1,32
1,64
1,35
1,75
2,04
1,57
2,39
3,18
2,08
2,81
3,74
1,62
2,12
2,64
2,22
2,90
3,35
2,56
3,93
5,23
3,43
4,63
6,17
219
280
340
316
402
461
387
574
745
506
667
863
4,5
7,0
10,0
4,9
7,6
9,7
4,6
9,4
15,1
7,5
12,4
19,7
4,0
6,0
9,0
4,1
6,3
8,2
3,5
7,3
11,4
6,7
11,2
17,7
25
32
57
25
32
44
25
44
68
32
57
90
kPa
P heating
Fan
A 0,11
Water content
0,15
0,27
0,11
0,15
0,20
0,11
0,20
0,32
0,15
0,27
0,45
0,8
0,8
0,8
1,4
1,4
1,4
2,1
2,1
2,1
2,1
2,1
2,1
33
40
49
33
40
45
33
45
53
41
49
59
24
31
40
24
31
36
24
36
44
32
40
50
dB(A)
CWC
800 x 800
520
420
2-pipe version
MIN
Speed
m /h
Airflow
Cooling capacity
Sensible cooling capacity
kW
Heating capacity
l/h
Water flow
P cooling
kPa
P heating
Fan
MAX
620
MED
MAX
MIN
MED
MAX
630
820
1140
710
970
1500
710
1280
1820
4,21
4,91
6,16
5,31
6,78
9,51
5,31
8,45
11,1
3,03
3,58
4,59
3,46
4,48
6,48
3,71
6,09
8,25
5,12
6,03
7,77
5,61
7,34
10,71
6,13
10,30
14,0
724
845
1060
913
1166
1636
913
1453
1909
10,9
14,3
21,6
9,4
14,7
26,9
9,4
21,8
35,6
9,9
15,1
7,9
12,4
23,0
7,9
18,6
30,6
33
48
77
42
63
120
42
95
170
0,15
0,23
0,36
0,18
0,28
0,53
0,18
0,42
0,74
3,0
3,0
3,0
4,0
4,0
4,0
4,0
4,0
4,0
33
40
48
34
40
53
34
48
58
24
31
39
25
31
44
25
39
49
CWC
040
4-pipe version
MIN
6,7
dB(A)
MED
Water content
Sound power level - Lw
320
MED
1,27
l/h
P cooling
220
MIN
kW 1,01
Heating capacity
Water flow
120
600 x 600
240
260
140
340
360
Speed
MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX
Airflow
m3/h 310 420 610 310 420 520 320 500 710 320 500 710 430 610 880 430 610 880
Cooling capacity
Sensible cooling capacity
kW
1,51 1,96 2,33 1,85 2,36 2,70 1,85 2,65 3,34 2,09 3,06 3,93 2,36 3,02 3,81 2,72 3,53 4,53
1,15 1,55 1,90 1,34 1,71 1,98 1,34 1,98 2,56 1,49 2,24 2,95 1,75 2,29 2,97 1,97 2,62 3,46
Water flow
l/h 260 337 401 318 406 464 318 456 574 359 526 676 406 519 655 468 607 779
P cooling
kPa 6,0 10,0 13,5 4,6 6,9 8,8 4,6 8,8 13,4 4,0 7,0 10,5 7,2 11,2 17,0 6,0 9,0 14,0
Heating capacity
kW 1,96 2,54 3,03 2,43 3,02 3,46 2,43 3,46 4,40 1,98 2,71 3,35 3,10 3,97 4,95 2,46 3,06 3,79
Water flow
l/h 169 219 261 209 260 298 209 298 378 170 233 288 267 341 426 212 263 326
P heating
kPa 6,5 10,5 14,5 5,7 8,5 10,8 5,7 10,8 16,6 3,6 6,0 9,0 8,8 13,8 20,5 5,0 7,8 11,0
W 25
Fan
32
57
25
32
44
25
44
68
25
44
68
32
57
90
32
57
90
A 0,11 0,15 0,27 0,11 0,15 0,20 0,11 0,50 0,32 0,11 0,20 0,32 0,15 0,27 0,45 0,15 0,27 0,45
Water content
Cooling mode
Water content
Heating mode
Sound power level - Lw
Sound pressure level - Lp
1,0 1,0 1,0 1,4 1,4 1,4 1,4 1,4 1,4 1,7 1,7 1,7 1,4 1,4 1,4 1,7 1,7 1,7
l
0,6 0,6 0,6 0,7 0,7 0,7 0,7 0,7 0,7 0,5 0,5 0,5 0,7 0,7 0,7 0,5 0,5 0,5
dB(A)
33
40
50
33
40
45
33
45
53
33
45
53
41
49
59
41
49
59
24
31
41
24
31
36
24
36
44
24
36
44
32
40
50
32
40
50
Cooling : Air inlet temperature: 27C D.B - 19C W.B/Water temperature 7/12 C.
Heating: Air inlet temperature: 20C - Water inlet temperature: 50C; water flow rate as in cooling mode.
The sound pressure levels apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 seconds.
Check ongoing validity of certificate :
eurovent-certification.com
certiflash.com
132
GC15-E_V1
440
4-pipe version
Speed
Airflow
Cooling capacity
Sensible cooling capacity
800 x 800
560
540
640
660
MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX
m3/h 630
kW
4,14 5,03 6,34 4,52 5,66 7,71 4,99 6,33 8,77 4,52 6,93 8,89 4,99 7,84 10,2
2,96 3,65 4,69 3,25 4,15 5,83 3,53 4,55 6,49 3,25 5,18 6,84 3,53 5,73 7,68
Water flow
l/h 712
P cooling
kPa
Heating capacity
kW 5,91 7,19 9,10 6,45 8,10 11,0 5,23 6,42 8,56 6,45 9,98 12,7 5,23 7,74 9,80
Water flow
l/h 508
618
946
450
552
736
P heating
kPa
9,8
6,5
9,2
6,5
33
42
63
120
42
Fan
Water content
Cooling mode
Water content
Heating mode
Sound power level - Lw
Sound pressure level - Lp
8,8
48
783
77
555
42
974 1326 858 1089 1508 777 1192 1529 858 1348 1754
697
63
120
9,0
9,0
170
20,0 32,0
666
843
13,0 19,5
95
170
A 0,15 0,23 0,36 0,18 0,28 0,53 0,18 0,28 0,53 0,18 0,42 0,74 0,18 0,42 0,74
3,0
3,0
3,0
3,0
3,0
3,0
3,6
3,6
3,6
6,0
6,0
6,0
3,6
3,6
3,6
1,4
1,4
1,4
1,4
1,4
1,4
1,1
1,1
1,1
1,4
1,4
1,4
1,1
1,1
1,1
33
40
48
34
40
53
34
40
53
34
48
58
34
48
58
24
31
39
25
31
44
25
31
44
25
39
49
25
39
49
dB(A)
600 x 600
220
120
2-pipe version
800 x 800
320
420
520
MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX
m3/h 310
kW
380
535
310
445
710
360
610
880
630
1,84 2,17 2,75 2,24 3,05 4,33 2,56 3,87 5,02 4,21 5,15 6,33 5,29 7,72 10,75
1,35 1,61 2,09 1,57 2,17 3,18 1,81 2,81 3,74 3,03 3,77 4,72 3,69 5,53 7,94
Water flow
l/h 317
373
473
385
524
744
441
666
P cooling
4,9
6,6
10,1
4,6
9,4
15,1
5,9
9,4
18,5 33,6
5,5
8,7
3,6
6,6
13,1
4,7
10,5 17,7
7,2
14,9 28,8
16
11
31
21
62
10
17
33
10
32
108
1,4
1,4
1,4
2,1
2,1
2,1
2,1
2,1
2,1
3,0
3,0
3,0
4,0
4,0
4,0
P heating
Fan
Water content
kPa
W
l
CWC EC
Speed
Airflow
Cooling capacity
Sensible cooling capacity
600 x 600
260
140
4-pipe version
864
723
8,7
800 x 800
360
440
560
MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX MIN MED MAX
m3/h 310
kW
880
630
380
535
310
445
710
360
610
4,3
1,34
1,6
2,08 1,49 2,04 2,95 1,71 2,62 3,46 3,08 3,84 4,83 3,52
Water flow
l/h 318
375
476
359
483
676
409
P cooling
kPa
6,2
9,5
3,5
5,7
10,5
Heating capacity
Water flow
l/h 209
245
311
170
217
P heating
kPa
5,7
7,6
11,7
3,5
5,5
16
1,4
1,4
1,4
0,7
0,7
33
24
Fan
Water content
Cooling mode
Water content
Heating mode
Sound power level - Lw
Sound pressure level - Lp
4,6
5,2
7,4
608
779
740
4,1
8,4
13,1
9,4
13,6 19,8
2,2
288
189
263
326
528
805
449
616
818
4,5
7,5
11
6,5
11
18
11
31
21
62
10
17
33
10
32
108
1,7
1,7
1,7
1,7
1,7
1,7
3,0
3,0
3,0
3,6
3,6
3,6
0,7
0,5
0,5
0,5
0,5
0,5
0,5
1,4
1,4
1,4
1,1
1,1
1,1
39
47
33
43
54
37
50
60
33
39
48
34
47
57
30
38
24
34
45
28
41
51
24
30
39
25
38
48
649
8,8
17
30,1
dB(A)
Cooling : Air inlet temperature: 27C D.B - 19C W.B/Water temperature 7/12 C.
Heating: Air inlet temperature: 20C - Water inlet temperature: 50C; water flow rate as in cooling mode.
The sound pressure levels apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 seconds.
Check ongoing validity of certificate :
eurovent-certification.com
certiflash.com
Non contractual photos
GC15-E_V1
133
2-pipe units
4-pipe units
Heating 1/2"
Heating 1/2"
Cooling 1/2"
Cooling 1/2"
Metallic diffuser
20 mm
50 m
m
14
mm
134
GC15-E_V1
2-pipe units
4-pipe units
GC15-E_V1
135
COANDAIR
COANDAIR EC
0,8 5,1 kW
182 750 m3/h
Main applications
Office buildings
Hotels
Schools
Hospitals
savings
General description
Centrifugal 2 way water cassettes engineered to obtain the best
Main components
G2 filter
valves)
99 to 124 mm)
Remote controls
EC fans for low Energy consumption
136
GC15-E_V1
General data
COANDAIR CD
Speed
06-3
06-4
09-3
09-4
12-3
12-4
1,17
1,26
1,35
1,48
1,65
1,79
1,43
1,48
1,83
2,05
2,22
2,44
1,96
1,83
2,35
2,66
3,07
3,44
1,56
1,76
1,85
2,08
2,30
2,54
1,88
2,04
2,47
2,83
3,05
3,43
2,50
2,48
3,10
3,61
4,13
4,75
268
306
318
357
395
436
324
349
424
486
524
589
430
427
532
621
710
816
2,40
10,7
4,16
6,30
7,70
11,3
9,01
13,6
7,03
11,0
11,2
19,5
15,1
19,6
10,7
17,2
22,4
35,1
NA
1,83
NA
2,14
NA
2,56
NA
2,14
NA
2,95
NA
3,53
NA
2,64
NA
3,85
NA
4,95
NA
159
NA
185
NA
222
NA
185
NA
256
NA
305
NA
229
NA
333
NA
429
NA
2,76
NA
1,63
NA
2,83
NA
3,69
NA
2,94
NA
5,05
NA
5,39
NA
4,75
NA
9,37
1,30
NA
1,61
NA
2,00
NA
1,54
NA
2,08
NA
2,55
NA
2,01
NA
2,56
NA
3,34
NA
113
NA
141
NA
175
NA
134
NA
182
NA
223
NA
176
NA
223
NA
292
NA
1,45
NA
4,89
NA
9,17
NA
3,26
NA
7,73
NA
14,3
NA
5,31
NA
11,2
NA
23,1
NA
43
43
37
37
37
37
44
44
42
42
43
43
44
44
52
52
53
53
42
42
39
39
34
34
46
46
45
45
38
38
51
51
50
50
48
48
kW
kW
4
2
Water flow - Cooling
l/h
4
2
Water pressure drop - Cooling
kPa
Heating capacity
kW
l/h
kPa
kW
l/h
kPa
4
Electrical data (230V/1Ph/50Hz)
2
Fan absorbed power
4
Acoustic data
2
Sound power level
3
4
dB(A)
NA = Non applicable
Data given at maximum speed
(1) Cooling: water inlet temperature: 7C; water outlet temperature: 12C; air inlet temperature: 27C D.B - 19C W.B
(2) Heating: water inlet temperature: 50C; water flow rate as in cooling mode; air inlet temperature: 20C
(3) Heating: water inlet temperature: 70C; water outlet temperature: 60C; air inlet temperature: 20C
GC15-E_V1
137
COANDAIR / COANDAIR EC
General data
Volts
COANDAIR EC
06-3
06-4
09-3
09-4
12-3
12-4
0,54
0,59
1,00
1,00
1,07
1,52
1,06
1,18
1,96
2,01
2,12
2,34
1,57
1,80
2,35
2,44
3,25
3,54
0,76
0,83
1,40
1,55
1,50
1,63
1,43
1,66
2,62
3,02
2,93
3,29
2,05
2,45
3,10
3,61
4,23
4,87
130
144
241
266
260
280
245
285
450
519
503
565
352
421
532
621
727
837
1,7
2,7
2,5
3,7
3,6
5,5
9,4
7,9
12,4
11,9
18
10,5
19,1
10,7
17,2
23,3
36,8
NA
0,84
NA
1,57
NA
1,62
NA
1,72
NA
3,17
NA
3,37
NA
2,60
NA
3,85
NA
5,09
NA
0,7
NA
0,9
NA
1,2
NA
2,5
NA
3,3
NA
4,6
NA
5,3
NA
4,8
NA
9,8
0,69
NA
1,3
NA
1,4
NA
1,2
NA
2,2
NA
2,47
NA
1,7
NA
2,56
NA
3,41
NA
60
73
111
136
123
140
105
148
192
274
216
292
145
224
223
333
298
441
0,8
NA
3,2
NA
4,8
NA
2,1
NA
8,5
NA
13,4
NA
3,7
NA
11,2
NA
24
NA
kW
kW
l/h
6
2
Water pressure drop - Cooling
kPa
Heating capacity
(3)
Water flow
kW
kPa
kW
l/h
kPa
18
18
30
30
30
30
50
50
42
42
39
39
34
34
46
46
45
45
38
38
51
51
50
50
48
48
Acoustic data
Sound power level
4
6
dB(A)
NA = Non applicable
Data given at maximum speed
(1) Cooling: water inlet temperature: 7C; water outlet temperature: 12C; air inlet temperature: 27C D.B - 19C W.B
(2) Heating: water inlet temperature: 50C; water flow rate as in cooling mode; air inlet temperature: 20C
(3) Heating: water inlet temperature: 70C; water outlet temperature: 60C; air inlet temperature: 20C
138
GC15-E_V1
COANDAIR / COANDAIR EC
Dimensions and weights
Standard (SE)
46
0
366
301
A
59
5
59
5
COANDAIR
06
09
12
595
895
1195
616
916
1216
655
955
1255
779
1079
1379
25
36
47
595
895
1195
616
916
1216
655
955
1255
779
1079
1379
26
37
48
06
09
12
595
895
1195
616
916
1216
655
955
1255
779
1079
1379
40
95
125
485
675
915
25
36
47
Standard (SE)
mm
C
D
kg
Weight
Raised (HE)
A
B
mm
C
D
kg
Weight
Ductable version
46
0
301
19
59
5
A
D
COANDAIR
Ducted
C
D
Weight
mm
kg
GC15-E_V1
139
REMOTE CONTROLS
Stand alone and communicating controls
Main applications
Office buildings
Residential buildings
Light industrial buildings
General description
Lennox mechanical and electronic remote controls have been especially designed to satisfy any request of control and to be
most efficient solutions in terms of comfort and energy saving for heating and cooling systems.
external contact
and fan
cooling changeover
Adjustable commissioning and
control parameters
Minimum and maximum
setpoint limitation
Backlit LCD
receiver
Auto timer mode with 8
programmable timers
Type of mounting/suitable
conduit boxes, with min 60
mm diameter, min 40 mm
depth
LXTFZ01M - Digital Thermostat Driving 0-10V for motorized valves and fan
2-pipe units/2-pipe + electrical heater units/4-pipe + EC fan units
Digital configurable thermostat
Manual or automatic heating/
actuators
cooling changeover
Accessories
QAH11.1 remote sensor : suitable as return sensor or
change-over sensor
GC15-E_V1
COMMUNICATING CONTROLLERS
LONWORKS
(CTRL2302D2A-L-DC)
Main applications
and BACNET
(CTRL2302D2A-B-DC)
protocols :
Office buildings
LennoxHydroControls system
Residential buildings
General description
The LENNOX controllers communicating on the LONWORKS network (LONWORKS 2.0, latest
Neuron microprocessor) or BACNET.
Terminal controllers allow room parameters management to optimize occupants comfort for our fan coils and ceiling cassettes
ranges.
LNS costs.
Accessories
RC-LCD-DC
RC-4F-DC
RC-IR-DC
RC-RF-DC
KNX protocol :
Features and benefits
KNX communication.
Operating voltage : 24V
Backlit display
PI/P control
Output for ON/OFF, PWM, 3-position or DC
setpoint
Control depending on the room temperature or the return
air temperature
Adjustable commissioning and control parameters.
sensor, etc...
GC15-E_V1
141
MINIAIR
2 44 kW
500 7400 m3/h
Main applications
Office buildings
Light industrial building
Hotels
General description
Compact air handling units in 7 different capacity sizes, 2 and 4 pipe systems or 2 pipe with electric heater.
Main components
Pre coated steel frame (white)
Sandwich panels, galvanized steel sheet metal inside and white pre-coated steel sheet metal outside. Mineral wool thermal
and sound insulation 10 mm thickness for sizes 10 to 40 and 20 mm for sizes 50 and 60
Inspection and extraction by lower removable panels for fans, coils and filters
Galvanized steel drain tray with a special fixing system for easy extraction; side condensate discharge
Multi speed direct driven double inlet forward curved fans (as accessory can be supplied with built-in frequency converter
142
GC15-E_V1
Adjusting dampers
3-way valves
Intake plenum
Mixing section
Silencer
F6 pocket filter
section
Post-heating section
Electrical post-heating section
Silencer section
Supply grill
Acoustic data
MINIAIR
10
20
30
40
50
60
63
78,6
85,1
90,8
93,1
93,9
103,4
125
79,4
82
84,8
85,9
86,6
83,2
250
77,6
82,9
85,6
87,2
88,3
88,7
500
69
72,3
75,4
77,4
78,8
78,6
70,4
73,2
75,3
76,5
77,3
80
2000
71,4
73,8
75,4
76,6
77,3
79,9
4000
66,9
70
72,1
73,8
75
77,6
8000
62,2
65,2
67,4
69,1
70,1
72,6
dB
84
89
93
95
96
104
dB(A)
77
80
83
84
85
87
(1)
63
66
69
69
70
72
5 m. (1)
52
54
57
58
59
61
(1)
46
49
52
53
54
56
1 m. (1)
51
55
57
58
57
59
1000
10 m.
Outside sound pressure level
dB
dB(A)
40
43
45
47
46
48
10 m. (1)
34
38
40
42
41
43
1 m.
(1)
60
63
66
66
67
69
5 m. (1)
49
51
54
55
56
58
43
46
49
50
51
53
5 m.
10 m.
(1)
(1)
GC15-E_V1
143
MINIAIR
General data
MINIAIR
10
20
30
40
50
60
1000
2000
3600
4200
5100
6500
890
1660
2700
2950
3100
4100
MIN
600
900
1800
1900
1800
2700
MAX
187
160
135
111
160
189
148
110
105
72
110
145
MIN
105
40
50
30
125
120
MAX
51
55
57
58
57
59
49
52
54
55
50
52
47
49
47
51
42
47
1,50
3,10
6,20
6,20
6,20
9,30
kW
0,36
0,75
1,36
1,50
1,62
2,43
W/(m3/s)
1105
1127
1225
1112
1026
1011
2 015
2013
2013
2013
2013
2013
IP44
IP55
IP44
IP20
IP20
MAX
Airflow rate
MED
m /h
3
Pa
MED
MED
(1)
dB(A)
MIN
Total current
Total power input
Specific fan power
2009/125/EC ErP compliant for year
Number of fan speed
Minimum protection degree
Minimum temperature class
B
230V/1Ph/50Hz
(1)
MAX
(1)
(1)
kW
8,77
16,30
27,00
31,80
33,30
43,20
m3/h
0,75
1,40
2,32
2,73
2,86
3,72
kPa
30
10
36
11
70
kW
13,0
25,4
42,5
50,4
59,4
73,5
m3/h
1,12
2,18
3,66
4,33
5,11
6,32
kPa
17
30
39
34
35
17
kW
5,72
11,30
18,50
21,90
27,10
30,70
kW
4,45
8,80
14,80
17,40
20,90
24,90
m3/h
0,98
1,94
3,18
3,77
4,66
5,28
kPa
14
24
30
26
30
12
kW
7,19
13,50
23,70
26,00
31,10
40,20
kW
5,25
10,10
17,70
20,00
24,30
31,00
m /h
1,24
2,32
4,08
4,47
5,35
6,91
13
36
4-row coil
Heating capacity
(1)
(1)
(1)
MAX
(2)
(2)
(1)
(1)
6-row coil
Total cooling capacity
(2)
MAX
(1)
MIN
(2)
kPa
(1)
Minimum speed
MED
MAX
Average speed
Maximum speed
144
GC15-E_V1
MINIAIR
Dimensions and weights
A2
C
Y
A1
X1
Airflow
X
X1
X2
X1
X2
MINIAIR
10
20
30
40
50
60
850
850
850
850
960
960
710
1070
1400
1680
1780
2000
390
390
390
390
480
480
3/4"
3/4"
3/4"
1"
1"
1"
3/4"
3/4"
1"
1"
1"
1" 1/4
3/4"
1"
1"
1" 1/4
1" 1/4
1" 1/4
20
20
20
20
20
20
X1
240
300
240
300
300
300
Y1
215
270
270
270
270
270
X2
335
535
580
360
A1
675
1035
1365
1645
1720
1940
A2
355
355
355
355
420
420
235
385
295
270
300
185
140
80
80
80
160
160
52/60
60/70
78/90
96/110
101/120
120/140
mm
2-row coil
4-row coil
6-row coil
X3
Weight
mm
kg
GC15-E_V1
145
MINIAIR +
General description
Compact air to air heat recovery units, vertical or horizontal, in 10 different capacity sizes.
Main components
components
Inlet/exhaust dampers
Mixing box 3 dampers section
Adiabatic cooling/humidifier section
Circular duct connection and flexible duct joint
Roof cover for outdoor installation
F6 compact filter
F6 soft bag filter
F7 soft bag filter
F8 soft bag filter
Air filter pressure switch
Antifreeze thermostat
230V damper motor
3-way valves
Frequency converter fan motors
146
GC15-E_V1
General data
MINIAIR +
03
06
10
14
19
25
30
40
50
60
300
500
930
1400
1900
2500
3200
4000
5000
6000
200
300
750
1200
1400
1700
2600
MIN
100
150
600
850
1000
1150
2100
3000
4000
5000
MAX
163
121
111
129
125
120
114
120
99
188
184
136
125
100
97
56
110
MIN
167
144
90
91
82
46
49
105
139
208
MAX
51
51
65
65
58
56
59
62
64
64
50
47
61
63
54
51
53
44
41
58
61
42
45
51
55
59
62
1,4
1,4
3,0
6,2
9,2
9,6
12,9
6,6
11,2
10,8
kW
0,34
0,34
0,72
1,36
2,06
2,14
2,82
3,78
7,24
7,72
W / (m3/s) 1376
1019
1027
1449
1172
1019
1301
1133
1428
1594
2013
2013
2015
2013
2013
2013
2013
2015
2015
2013
IP 32
IP 32
IP 44
IP 44
IP 20
IP 20
IP 20
IP 55
IP 55
IP 20
Speed
MAX
Airflow rate
MED
MED
MED
(1)
m /h
3
Pa
dB(A)
MIN
Total current
Recovery efficiency
Supply temperature
57
51,2
50,3
55,5
53,9
55,7
62,2
58
52,1
52,1
57,9
55,2
MIN
59,6
66,8
58,8
54,1
54
60,3
56,6
56,7
55,3
54,3
MAX
1,3
2,4
4,4
6,0
7,9
11,5
14,3
18,2
22,4
26,5
0,9
1,6
3,9
5,2
6,1
8,2
11,9
MIN
0,5
0,8
3,5
3,8
4,5
5,8
9,9
14,1
18,4
22,6
MAX
7,1
8,3
7,9
6,6
6,4
7,6
7,2
7,4
7,2
7,1
7,6
9,1
8,2
6,8
6,8
8,1
7,5
8,5
10,1
8,3
7,3
7,3
8,7
7,8
MED
(2)
58,7
MED
(1)
53,3
MED
(1)
kW
MIN
54,9
53,8
53,1
7,9
7,5
7,3
Minimum speed
MED
Average speed
MAX
Maximum speed
GC15-E_V1
147
MINIAIR+
General data - Accessories
MINIAIR +
Heating capacity
Electrical coil
(LXMAPSKE)
Heating coil
3R (2)
(LXMAPSKW)
Cooling coil
3R (3)
(LXMAPSAF)
Air side T
(1)
03
06
10
14
19
25
30
40
50
60
kW
4,5
12
12
12
18
24
20
24
13
13
14
14
11
11
12
V/Ph/Hz
kPa
Heating capacity
kW
230 V/
1 Ph/
50 Hz
8
11
10
11
13
15
9,6
14,9
18,6
26,9
31,5
39,5
46,7
53,8
35,1
34,3
32
35,6
33
33,2
28,8
27,9
Pa
58
63
85
62
85
90
94
111
kPa
15
41
28
21
29
53
23
26
kW
2,3
3,1
5,7
8,2
10,8
16,5
19,2
24,0
27,9
28,2
19,5
20,9
20,9
21,7
21,9
20,6
21,5
21,3
21,3
21,3
Pa
43
59
63
81
83
64
84
84
66
69
kPa
11
15
10
22
29
30
27
24
26
45
51
43
50
47
38
34
145
170
162
172
189
175
179
171
199
191
197
229
205
185
214
239
230
238
260
248
225
(1)
(1)
Acoustic data
03
MINIAIR
14
19
25
30
40
50
60
63
78,6
78,6
72,4
94,1
90,7
93,1
103,0
95,4
110,0
111,0
79,4
79,4
78,9
86,9
82,9
85,9
83,2
89,0
89,9
90,9
250
77,6
77,6
75,9
92,4
90,1
87,2
88,7
92,5
93,6
94,6
500
69,0
69,0
71,1
85,6
79,4
77,4
78,6
87,7
84,2
85,2
1000
dB
70,4
70,4
72,8
80,9
78,6
76,5
80,0
81,5
84,1
85,1
2000
71,4
71,4
73,7
81,8
79,5
76,6
79,9
82,6
84,5
85,5
4000
66,9
66,9
71,7
82,7
79,3
73,8
77,6
83,5
82,8
83,8
8000
62,2
62,2
69,0
78,2
75,5
69,1
72,6
79,0
78,5
79,5
dB
84,0
84,0
83,0
98,0
94,0
95,0
104,0
99,0
110,0
111,0
dB(A)
77,0
77,0
79,0
90,0
87,0
84,0
87,0
91,0
92,0
93,0
(1)
63,0
63,0
65,0
76,0
72,0
69,0
72,0
76,0
76,0
77,0
5 m. (1)
52,0
52,0
53,0
64,0
61,0
58,0
61,0
65,0
66,0
67,0
10 m. (1)
46,0
46,0
48,0
59,0
56,0
53,0
56,0
60,0
61,0
62,0
1 m. (1)
60,0
60,0
62,0
73,0
69,0
66,0
69,0
72,0
73,0
74,0
1 m.
10
125
06
dB(A)
49,0
49,0
50,0
61,0
58,0
55,0
58,0
61,0
63,0
64,0
10 m. (1)
43,0
43,0
45,0
56,0
53,0
50,0
53,0
56,0
58,0
59,0
1 m. (1)
51,0
51,0
52,0
62,0
58,0
56,0
59,0
62,0
64,0
65,0
5 m. (1)
40,0
40,0
40,0
50,0
47,0
45,0
48,0
51,0
54,0
55,0
10 m. (1)
34,0
34,0
35,0
45,0
42,0
40,0
43,0
46,0
49,0
50,0
5 m.
(1)
148
GC15-E_V1
MINIAIR+
Possible installations
Horizontal configuration
Type A
OUTSIDE
INSIDE
OUTSIDE
INSIDE
Type B
Fresh air
Return air
Exhaust air
Supply air
Exhaust air
Supply air
Fresh air
Return air
Type C
Type D
INSIDE
Supply air
Return air
Exhaust air
Fresh air
OUTSIDE
Exhaust air
Fresh air
Supply air
Return air
OUTSIDE
INSIDE
Type B
Fresh air
Return air
Exhaust air
Supply air
Exhaust air
Supply air
Fresh air
Return air
Type C
Type D
Supply air
Return air
Fresh air
Exhaust air
Fresh air
Exhaust air
Supply air
Return air
RxT
RxT
RxT
SKR
P
d
Non contractual photos
SAF
RKE
MS3
GC15-E_V1
149
MINIAIR+
Dimensions and weights
H1
L1
L
Filter
HORIZONTAL UNIT
VERTICAL UNIT
Possible post-heating
A
L1
90
"
H1
MINIAIR +
03
06
10
14
19
25
30
40
50
60
990
990
1150
1350
1450
1700
1700
1700
1700
1900
750
750
860
900
900
1230
1230
1230
1350
1450
270
270
385
410
470
490
530
630
705
755
230
230
280
305
305
405
480
530
1"
1"
mm
C
D
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
195
195
245
241
241
323
308
308
170
170
238
224
284
290
331
377
197
197
225
241
241
323
323
323
100
100
218
270
270
270
297
297
mm
H1
353
379
153
153
267
267
327
347
387
487
162
162
240
240
240
306
339
339
L1
275
275
330
337
337
502
502
502
555
615
119
119
81
81
81
131
101
101
101
101
Weight
kg
O
P
mm
Q
R
555
615
39
41
68
91
99
140
155
179
235
273
375
375
430
450
450
615
615
615
675
725
400
400
400
700
700
700
700
800
850
900
450
480
480
650
650
650
707
757
210
210
310
310
410
410
410
510
610
610
280
280
330
330
330
500
500
500
600
600
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1" 1/2
1" 1/2
GC15-E_V1
MINIAIR + FO
Heat recovery unit with high efficiency filters and built-in control (LXMAPRQU)
General description
MINIAIR + FO versions includes motor with frequency converter, high efficiency filters (class F6, F7 or F8), air filter pressure
switches and electronic built-in control LXMAPRQU for:
Heating/cooling/free-cooling automatic mode (2/4 pipe
plant)
Antifreeze
Electric heater on/off mode
Winter heating speed-up
Available versions
LXMAPFO1 : with G4 filter on return and F6 on supply side
LXMAPFO2 : with G4 filter on return and G4+F6 on supply side
LXMAPFO3 : with G4 filter on return and G4+F7 on supply side
SS
P
SS
SS
TR
TM
SS
SV
SV
Available accessories
Adiabatic cooling section
Electric heater
Pressure sensor
Damper
General data
MINIAIR + FO
Airflow rate
m /h
Shaft power
Maximum current
14
19
1400
1900
25
30
40
2500
3200
4000
2 x 560
10,2
10,2
11,2
Protection class
(1)
4500
5000
2 x 920
9,6
14,4
14,4
14,8
Power supply
Recovery
60
IP 54
Temperature class
Recovery efficiency
50
V/Ph/Hz
(1)
230/1/50
51,2
50,3
55,5
53,9
54,9
54,5
54,3
kW
7,6
13,5
15,5
20,2
22
23,4
(1) Room air temperature 20C D.B., 50% R.H.; fresh air temperature : -5C.
Non contractual photos
GC15-E_V1
151
MINIAIR + BP
General description
MINIAIR + BP is the configuration of MINIAIR + with integrated by-pass for free-cooling.
Available accessories
Electric heater
Water cooling coil external section
Adiabatic cooling/humidify section
Round adapter for circular duct
3-damper mixing box
Damper connection lever
F6 compact filter
F6 soft bag filter
F7 soft bag filter
F8 soft bag filter
Frequency converter fan-motors
Roof cover
Adjusting damper
Antivibrating flexible joint
Casing with bird net
Supports legs H 90 (kit 4 p)
Supports legs H 200 (kit 4 p)
Control
152
GC15-E_V1
General data
MINIAIR + BP
Airflow rate
Speed
10
14
19
30
40
60
MAX
750
1100
1600
2 600
3400
5500
m3/h
MED
MIN
MAX
Pa
MED
MIN
MAX
dB(A)
MED
(1)
MIN
Maximum current
Number of poles
Minimum protection degree
600
1000
1400
2250
500
800
1000
1500
2500
119
115
145
144
156
115
108
38
141
90
63
48
176
155
52,0
59,1
58,0
58,8
61,4
50,3
56,1
54,5
55,4
47,9
45,8
45,5
55,1
54,7
61,9
3,0
6,2
9,2
12,9
6,6
10,8
269
64,0
-
IP44
IP20
IP20
IP55
IP20
F
230 V/1 Ph/50 Hz
MAX
50,7
50,1
53,5
57,4
51,2
50,8
54,4
58,7
52,5
52,8
57,0
55,5
3,5
4,6
6,7
11,6
15,1
2,9
4,3
5,9
10,2
MIN
2,4
3,5
4,4
7,1
11,5
18,2
MAX
7,7
6,5
6,4
7,1
7,1
7,0
8,0
6,6
6,5
7,3
8,3
6,9
7,9
MIN
MAX
kW
MED
(1)
MED
(1)
55,9
MED
(1)
Supply temperature
160
-
4000
IP44
Recovery efficiency
MIN
H4
53,5
52,8
54,9
24,1
-
7,6
7,4
H5
Acoustic data
dB
85,7
97,9
104,3
100,0
101,9
100,4
dB(A)
80,0
87,0
85,0
87,0
89,0
94,0
(2)
65,0
74,0
72,0
72,0
76,0
77,0
5 m. (2)
53,0
62,0
61,0
61,0
65,0
67,0
48,0
57,0
56,0
56,0
60,0
62,0
62,0
71,0
69,0
69,0
72,0
74,0
50,0
59,0
58,0
58,0
61,0
64,0
(2)
45,0
54,0
53,0
53,0
56,0
59,0
1 m. (2)
52,0
59,0
58,0
59,0
61,0
64,0
5 m.
(2)
40,0
47,0
47,0
48,0
50,0
54,0
10 m. (2)
35,0
42,0
42,0
43,0
45,0
49,0
10 m.
(2)
1 m.
(2)
5 m. (2)
10 m.
dB(A)
Summer operation :
Fresh air 32C 50% RH, ambient air 26C 50% RH
Minimum speed
MED
Average speed
MAX
Maximum speed
GC15-E_V1
153
MINIAIR + BF
Heat recovery unit with integrated by-pass for free-cooling, high efficiency filters and builtin control (LXMAPRQU)
3
1100 4800 m /h
Main applications
Any commercial or residential building
General description
MINIAIR + BF includes motorized integrated by-pass motor
with frequency converter, high efficiency filters (class F6, F7 or
F8), air filter pressure switches and electronic built-in control.
Electronic built-in control LXMAPRQU allows:
Heating/cooling/free-cooling automatic mode (2/4 pipe
plant)
Antifreeze
Electric heater on/off mode
Winter heating speed-up
Heat recovery defrost
Manual or automatic fan speed selection
Dirty filter alarm
Timer
Available versions
LXMAPBF1 : with G4 filter on return and F6 on supply side
LXMAPBF2 : with G4 filter on return and G4+F6 on supply
side
side
side
side
LXMAPBF7 : with F6 filter on return and F6F+8 on supply
side
Available accessories
Adiabatic cooling section
Electric heater
Pressure sensor
Damper
General data
MINIAIR + BF
Airflow rate
Nominal absorbed power
14
19
30
40
60
m3/h
1100
1600
2600
3400
4800
2400
2400
2300
3500
3500
10,2
10,2
9,6
14,4
14,8
Maximum current
Protection class
IP 54
Temperature class
F
V/Ph/Hz
Power supply
Recovery efficiency
Recovery
(1)
230/1/50
50,7
50,1
53,5
53,5
53,7
kW
4,6
6,7
11,6
15,1
21,4
(1)
(1) Room air temperature 20C DB, 50% RH; fresh air temperature : -5C.
154
GC15-E_V1
MINIAIR +/
MINIAIR + BP/FO/BF
Controls
Accessories :
LXMAPSSE : ON/OFF damper servocontrol supply 230V
LXMAPPSTD : air filter pressure swithc
SS
SS
TR
TM
SS
SV
SV
Airflow control
LXMAPAQS, ductable CO2 sensor, must be connected to the LXMAPRQU control.
LXMAPKAQ, air quality control system includes:
Ductable CO2 sensor
Modulating control
24V transformer
LXMAPAQS
LXMAPRQU
GC15-E_V1
155
CLEANAIR LX
Modular air handling unit
restaurants, shops, )
Industrial buildings
Hospitals
General description
Construction
156
GC15-E_V1
Empty sections
Mixing box with external or internal damper
3-way in line mixing box external or internal damper
Roof (aluminium alloy perimetral rain shelter suitable for
outdoor unit application, with PVC joints covers and mansafe covers on the angles)
Drain pans:
Fan sections:
GC15-E_V1
157
AXIL / EQUITHERM
Unit heater/Destratifier fan
12 105 kW
Main applications
Industrial buildings
Large surfaces
General description
AXIL unit heaters and EQUITHERM destratifier fans are
suitable to any industrial building or big surface and are able
to reach very high performances thanks to their advanced
engineering.
Available configurations:
AXIL: hot water version
AXIL F: chilled water version
AXIL Z: electrical heating version
Main components
Main casing in galvanized prepainted steel finished in
dove grey
Hermetically
Operating limits:
120C 16 bars hot water for AXIL and AXIL F
210C 20 bars steam and superheated water
Star/Delta switch
158
GC15-E_V1
filter
actuator
General data
AXIL
402-4
403-4
404-4
502-4
503-4
504-4
602-4
602-6
Technical information
m3/h 2300/1600 2200/1500 2000/1400 3950/2550 3800/2500 3400/2150 6500/4500 4500/3700
Airflow rate
Heating capacity
Number of rows
Motor poles
4/6
4/6
4/6
4/6
4/6
4/6
4/6
6/8
Fan speed
Water connection
Sound pressure level at 5 m
dB(A)
11/4
11/4
59/51
59/51
59/51
64/54
64/54
64/54
69/60
60/52
3-4
3-4
3-4
3,5-4,5
3,5-4,5
3,5-4,5
4,5-6
4-5,5
2,5/3,5
2,5 - 3,5
2,5 - 3,5
3-4
3-4
3-4
4-5,5
3,5-5
11
10
9,5
16
15
14
25
18
7,5
7,5
12
10
19
15
4,5
4,5
4,5
5,5
5,5
5,5
3,5
3,5
3,5
4,5
4,5
4,5
5,5
60
58
56
80
75
70
145
110
45
43
41
60
55
50
125
90
AXIL
603-4
603-6
604-4
604-6
902-6
903-6
904-6
Technical information
m3/h 6200/4350 4350/3600 5500/4000 4000/3150 9500/7200 9100/6000 8500/6500
Airflow rate
Heating capacity
kW 58,1/47,3
Number of rows
47,3/41,3
69,8/53,5
53,5/45,5
73,1/63,1
Motor poles
4/6
96,0/82,0 111,9/89,9
3
6/8
4/6
6/8
6/8
6/8
6/8
950/700
1350/950
950/700
950/700
950/700
950/700
11/4
11/4
11/4
11/4
11/2
11/2
11/2
69/60
60/52
69/60
60/52
68/62
68/62
68/62
4,5-6
4-5,5
4,5-6
4-5,5
4-6
4-6
4-6
4-5,5
3,5-5
4-5,5
3,5-5
3,5-5,5
3,5-5,5
3,5-5,5
23
16
22
15
28
25
22
17
13
18
12
21
18
15
11
11
11
RPM 1350/950
Fan speed
Water connection
Sound pressure level at 5 m
dB(A)
5,5
5,5
135
100
125
90
200
180
160
115
80
105
70
160
140
120
AXIL F
403-4
404-4
503-4
504-4
603-6
604-6
903-6
904-6
Technical information
m3/h
Airflow rate
Total cooling capacity
(1)
(1)
1600
1600
2500
2500
3600
3600
6900
6900
kW
4,8
5,7
8,2
9,6
12,5
14,4
22,7
25,6
kW
3,4
4,0
5,9
6,6
8,7
9,7
16,0
17,5
4/6
4/6
4/6
4/6
6/8
Number of rows
Motor poles
Fan speed
dB(A)
6/8
6/8
6/8
950/700
950/700
950/700
51
51
54
54
52
52
62
62
2,5/3,5
2,5/3,5
3-4
3-4
3,5-5
3,5-5
3,5-5,5
3,5-5,5
7,5
10
13
12
18
15
GC15-E_V1
159
414
524
639
1560
2910
4790
m3/h
kW
14 (7+7)
24 (12+12)
39 (3 x 13)
25,7
23,6
23,3
Stages
Motor poles
Fan speed
RPM
900
900
900
dB(A)
51
54
60
AXIL V
402-4
502-4
602-4
902-6
m3/h
2100/1400
3600/2400
6300/4100
9200/7000
kW
18,6/15,1
29,9/24,6
49,6/40,3
87,7/78,4
kW
32,1/26,2
52,2/43,2
87,2/70,3
154,6/138,6
Technical information
Airflow rate
Number of rows
Motor poles
4/6
4/6
4/6
6/8
Fan speed
RPM
1350/950
1350/950
1350/950
950/700
dB(A)
59/51
64/54
69/60
68/62
3-4
3,5-4,5
4,5-6
4-6
2,5/3,5
3-4
4-5,5
3,5-5,5
11
16
25
28
7,5
12
19
21
EQUITHERM
Airflow rate
404
406
504
506
604
606
906
908
m3/h
2500
1700
4200
3000
7500
5200
13000
8500
RPM
1400
900
1400
900
1400
900
900
700
5-7
3-6
7 - 10
6-8
7 - 12
6 - 10
8 - 12
6 - 10
59
51
64
54
69
60
68
62
Motor poles
Fan speed
Installation height
Sound pressure level at 5 m
dB(A)
AXIL F
AXIL V
GC15-E_V1
Without control
AXIL Z
With control
414
524
639
A2
526
636
743
B1
450
550
641
mm
B2
394
500
610
468
468
468
506
616
723
AXIL Z
Weight without control
414
524
639
22
30
38
24
32
40
kg
Weight with control
EQUITHERM
EQUITHERM
400
500
600
900
A2
526
636
743
1011
B1
450
550
641
885
394
500
610
875
468
468
468
576
506
616
723
991
14
20
25
42
mm
B2
C
M
Weight
kg
4...
5...
6...
9...
AXIL / -V / -F
4...
5...
6...
9...
A1
537
647
754
1022
F2
64,5
69,5
77,5
89,5
526
636
743
1011
F3
98
69,5
77,5
89,5
450
550
641
885
69
69
60
91,5
B2
394
500
640
875
468
468
468
576
154
154
154
150
1"
1"
1" 1/4
1" 1/2
48
48
48
50
E1
397
467
588
832
88
88
88
90
330
467
588
832
506
616
723
991
75,5
80,5
88,5
100,5
542
650
758
1026
A2
B1
E2
F1
mm
mm
AXIL / -V / -F
H
I
mm
4...
5...
6...
9...
1,4
2,1
3,1
6,1
1,9
2,9
4,3
8,4
2,7
5,7
11,2
Water
2R
Content
3R
4R
2R
Weight
3R
22
25
34
81
23
28
39
90
25
32
45
100
2,5
4,5
5,9
12
kg
30
38
51
92
kg
4R
Steam
Content
Weight
Non contractual photos
GC15-E_V1
161
162
GC15-E_V1
Telecom unit
@DNOVA
2,5 38 kW
164
166
170
172
GC15-E_V1
163
@DNOVA
Telecom unit
2,5 38 kW
Main applications
Telecom shelters
General description
Main components
The installation is a simple and fast The THN and the THX
are plug and play systems which requires just screw fitting
and electrical cable connections.
For maintenance and service activities, all components are
fully accessible from the front of the units. No further access
of service staff to the sensitive internal is required.
Available types and configurations
THN : Wall mounted packaged indoor unit (Upflow/
Downflow/Displacement)
THX : Wall mounted packaged outdoor unit (Upflow/
Downflow on request for several models)
THX D : Wall mounted packaged outdoor unit (Downflow)
THS : Ceiling mounted split unit
Control
The ADNOVA are fitted as standard with Basic Microprocessor with LCD display.
Available options
164
Emergency Free-cooling
Free-cooling
Free-cooling technology
Microprocessor
GC15-E_V1
General Data
ADNOVA - THN - R410A
Total cooling capacity
0045 0056 0073 0090 0105 0120 0150 0170 0180 0200 0220 0250
(1)
kW
4,3
6,0
4,3
1
7,0
10,8
10,7
12,7
5,4
6,6
10,6
10,7
11,5
0,9
0.95
0.99
0.91
14,9
16,3
17,7
20,9
24,8
27,9
14,7
15,4
17,7
20,9
24,8
26,2
0,99
0,95
0,94
1r
(2)
m3/h 1450 1450 2100 3020 3020 3020 3800 3800 5500 5500 6500 6500
69
69
69
72
72
72
72
72
80
80
81
82
41
41
41
44
44
44
44
44
52
52
53
54
1850 1850 1850 1850 1850 1850 1850 1850 2050 2050 2050 2050
Width
mm 800
800
800
Depth
550
550
550
550
kW
Airflow rate
dB(A)
Height
Width
mm
Depth
800
800
800
7,2
10
10,8
11,2
12,7
14,4
14,7
23
28,8
5,1
6,6
9,2
10,7
9,5
11,5
13,2
12,9
23
27,1
0,88
0,92
0,92
0,99
0,85
0,91
0,92
0,88
0,94
1r
1450
2150
3020
2800
3020
3020
2800
6500
6500
69
70
70
72
71
71
72
71
74
74
82
82
42
43
43
45
44
44
45
44
46
46
51
51
1580
1580
1580
1790 1630
1630
1790
1790
1790
1790
2050
2050
804
804
804
1000 1000
1000
1000
1000
1000
1000
1600
1600
498
498
498
596 596
596
596
596
596
596
815
815
(1)
kW
0056H
0073H
4,3
5,9
6,6
9,1
4,3
5,3
5,6
7,28
Airflow rate
m /h
dB(A)
mm
Depth
0090H
0105H
0120H
0145H
10,2
12,7
13,3
10,2
11,9
12,2
0,9
0,85
0,8
0,94
0,92
1r
1400
1400
1400
1400
3200
3200
69
70
70
70
71
71
74
41
43
43
43
44
44
46
1040
1040
1040
1040
1040
1040
1040
2145
2145
2145
2275
2275
2275
2275
730
730
730
730
730
730
730
(2)
3
2800 3020
0045H
3200
025H 035H 045H 056H 073H 090H 105H 120H 145H 310H 381H
2,9
4,1
4,6
6,3
7,6
9,8
10,5
13,4
15,4
31,2
39,1
2,9
4,6
5,6
7,2
9,3
12,3
13,2
30,5
34
0,99
0,89
0,95
0,92
0,89
0,92
0,86
0,98
0,87
1r
1r
1r
950
930
1400
1400
2300
2300
2300
3200
3200
7750
7750
2250
2050
3450
3350
3350
5100
5100
5580
5450
9300
16280
62
65
65
67
68
65
71
68
70
73
75
34
37
37
39
40
37
42
40
42
45
47
mm
350
590
1040
350
590
1040
350
990
1040
350
990
1040
350
990
1040
350
990
1040
350
990
1040
400
1090
1140
400
1090
1140
685
1090
1500
675
1090
1500
mm
580
600
350
580
600
350
630
990
360
630
990
360
630
990
360
630
990
360
630
990
360
1128
1120
578
1128
1120
578
1300
1565
600
1485
1990
950
(1)
kW
800
5,9
550
4,2
m /h 1450
550
4,2
550
045H 056H 073H 0902H 090H 105H 1102H 120H 145H 1302H 230H 290H
(1)
550
(2)
m3/h
dB(A)
Indoor unit
Height
Width
Depth
Outdoor unit
Height
Width
Depth
GC15-E_V1
165
INNOV@
DX : 6 128 kW
CW : 8 240 kW
Main applications
Computer rooms
Data centers
General description
The series of INNOV@ Close Control Air Conditioning units
are designed to guarantee and respect all environment
protection parameters; they represent the perfect answer
to all technical requirements of different technological
plant concepts (computer rooms, datacenters, control
rooms, EDP rooms, textile industry, metrological
rooms, etc ...).
The exclusive design with rounded edges, innovative colour
and the excellent performances of the INNOV@ series have
become the new high quality standard in the close control
air conditioning sector. R410A is a new option.
Available configurations
Downflow version
Upflow version
Displacement version
Main components
All main components are reachable from the front of the unit
in order to reduce costs for installation and maintenance:
electrical panel, compressor, fans, humidifier, electrical heaters, expansion valve and liquid flow filter can be reached by
just opening the front panel. This guarantees fast and safe
intervention.
166
GC15-E_V1
Operating mode
Air cooled with remote condenser
Water cooled with remote dry-cooler
Water cooled for city tap water
Chilled water
Indirect free-cooling
Water cooled with remote dry-cooler and indirect free-
cooling
Control
The microprocessor control, available in Basic or Advanced
Graphics version, manages all functions of the INNOV@
series. This control offers the opportunity to connect up to
8 units together creating a local network (LAN) and allowing,
among different options, to balance operation times in an
automatic stand by and rotation function. The microprocessor controls are available with a LCD display (Basic version)
or with a graphic display (Advanced version) and are compatible with the most wide spread communication protocols.
LENNOX Software Development Team (LSDT) moreover, is
able to develop control strategies according to customers
special requirements.
coil
Water cooled for city tap water and chilled water coil
Flash memory
Microprocessor
Electronic condenser fans speed control
Interconnectivity (ModBus, TCP/IP, Bacnet ...)
Touch screen graphic display
GC15-E_V1
167
INNOV@
General data
DM RANGE / Air cooled and water cooled INNOV@ DX
INNOV@ DX - R410A
0060 0080 0100 0110 0130 0132 0160 0190 0205 0212
Airflow rate
Maximum available static pressure
m3/h
1785
2150
3530
3530
3700
Pa
776
725
624
624
574
5100
5100
574
292
292
292
292
8,5
10,7
11,8
13,8
13
16,6
19,4
22,4
22,6
6,7
8,1
10,5
11,6
13,9
12,9
16,6
19,5
21,5
22,2
0,99
0,94
0,98
0,97
0,89
0,91
1,00
0,96
0,89
0,89
0,97
0,97
1,00
0,98
0,90
0,91
0,99
0,96
0,91
0,89
1/1
1/1
1/1
1/1
1/1
2/2
1/1
1/1
1/1
2/2
600
600
900
900
900
900
900
900
900
900
kW
(2)
1875
Length
mm
Depth
600
Air cooled unit
Weight
Sound pressure level
5100
6,5
5100
1
Air cooled unit (1)
3700
kg
dB(A)
(3)
150
157
195
210
230
230
245
255
260
264
165
172
214
231
253
253
269
280
286
291
49
52
52
53
53
55
56
56
56
47
0080
0110
0140
0160
0200
0230
m3/h
2300
2400
3800
3800
5100
5100
Pa
716
678
573
552
320
293
1
kW
(1)
7,4
10,4
10,9
15,0
17,7
21,6
0,96
0,87
1,00
0,93
1,00
0,91
900
900
900
Height
1875
Length
mm
600
600
900
Depth
600
Weight
Sound pressure level
(2)
kg
140
150
165
175
187
190
dB(A)
50
51
53
53
55
55
(2) 1,5 meter above and 2 meters from the unit in free field downflow units
(30 Pa AESP), nominal airflow rate, compressor speed 50Hz
Airflow rate
Maximum available static pressure
m3/h
6800
6800
7280
7280
12950
12950
12950
12950
12950
Pa
397
397
329
329
412
412
412
412
412
23,4
25,9
30,2
33,6
42
27,1
34,2
37,7
45
23,4
25,5
29,9
32,5
43,7
28,1
34,2
39,2
43,7
0,97
0,95
0,93
0,88
0,95
1,00
1,00
0,94
0,97
0,95
0,92
0,88
0,95
1,00
1,00
0,95
1/1
1/1
1/1
1/1
1/1
2/2
2/2
2/2
2/2
1998
1998
1998
1998
1998
1998
1998
1998
1998
1010
1010
1280
1280
1760
1760
1760
1760
1760
795
795
795
795
795
795
795
795
795
375
385
394
401
552
565
580
590
605
412
423
433
442
611
621
638
649
665
55
56
58
58
63
59
61
62
65
kW
mm
Depth
Air cooled unit
Weight
Sound pressure level
168
GC15-E_V1
kg
dB(A)
INNOV@
DH RANGE / Air cooled and water cooled INNOV@ DX
INNOV@ DX
0452 0532
Airflow rate
m3/h 12950
14150
19415
19415
19415
21500
21500
24000
686
539
539
667
667
667
226
226
440
49,9
57,7
61,9
66,1
75,4
82,5
88,9
98,4
125,7
48,1
55,4
61,1
64,9
72,8
79,5
84,9
96,8
126,1
0,9
0,9
0,86
0,88
0,89
0,86
0,92
0,87
0,82
0,91
0,88
0,85
0,89
0,87
0,84
0,94
0,87
0,81
2/2
2/2
2/2
2/2
2/2
2/2
2/2
2/2
4/2
1760
2030
2030
2510
2510
2510
2510
2510
3160
795
795
795
795
795
795
950
950
950
615
740
905
940
958
979
1001
1013
1390
676
985
995
1034
1053
1076
1099
1114
1529
65
67
67
68
68
68
76
76
79
Pa
14150
kW
1998
Length
mm
Depth
Air cooled unit
Weight
Sound pressure level
kg
dB(A)
Performances given considering units installed in combination with the suggested remote condenser and with 35C outside air temperature
(1) Indoor conditions 24C/ 50%.
(2) Indoor conditions 24C/ 50%.- Water temperature 40/45C
(3) 1,5 meter above and 2 meters from the unit in free field downflow units (30 Pa AESP), nominal airflow rate, compressor speed 50Hz
0300
0380
0450
0550
0650
0750
m /h
7450
7450
9120
9120
14550
14550
Pa
401
349
229
206
355
320
kW
26,2
40,3
47,9
53,5
70,9
81,1
0,94
0,80
0,81
0,77
0,83
0,79
1270
1760
1760
(1)
1998
Length
mm
1010
1010
1270
kg
310
350
360
395
430
475
dB(A)
58
60
62
63
62
62
0890
1090
1200
1500
1800
2100
18020
18020
21400
26200
26200
36120
166
133
313
99
85
142
93,3
109,6
125,4
150,6
165,4
232,1
0,80
0,76
0,77
0,78
0,75
0,75
2020
2020
2510
2510
2510
3160
Depth
795
Weight
Sound pressure level
(2)
INNOV@ CW
Airflow rate
m3/h
Pa
(1)
kW
1998
mm
Length
Depth
Weight
Sound pressure level
(2)
795
795
795
950
950
950
kg
470
497
530
720
753
785
dB(A)
66
67
65
71
72
74
GC15-E_V1
169
3 90 kW
Main applications
Computer rooms
Data centers
General description
The INNOV@ ENERGY Inverter close control air conditioning units introduce modulating cooling capacity for computer
room and datacenter solutions. e-Drive technology integrated in close control unit allows to optimize cooling capacity to the
requirement, especially in X-treme density environments where the cooling capacity is normally lower than the design value.
Modulating cooling capacity from 25 100%, combined with quick reaction against heat load variation [6 Hz/second] INNOV@
ENERGY INVERTER introduces a new flexibility in close control air-conditioning.
Variable temperature control combined with the related power consumption lives up to the required energy efficiency.
Thanks to EC motors, obviously on fans but also on compressors we are able to maximize the energy saving.
Highest energy efficiency, smallest dimensions and lowest noise levels: these were LENNOXs targets when developing its
INNOV@ ENERGY series, units designed in order to operate 24 hours a day, 365 days a year delivering only required cooling.
The reduction of energy consumption in comparison with traditional technologies reaches values up to 45%.
Main components
Control
All main components are reachable from the front of the unit
in order to reduce costs for installation and maintenance:
electrical panel, compressor, fans, humidifier, electrical
heaters, expansion valve and liquid flow filter can be reached
by just opening the front panel. This guarantees fast and
safe intervention.
Only internationally recognised quality components and
latest technology devices are used in the INNOV@ ENERGY
series in order to guarantee top efficiency and reliability.
Standard technical features such as electronic expansion
valves, backward curved fan with EC motors offers various
opportunities in energy saving.
170
GC15-E_V1
Available configurations
Downflow version
Upflow version
Displacement version
General Data
INNOV@ ENERGY INVERTER - R410A
Airflow rate
0091
0131
0241
0341
0462
0682
0902
m /h
2150
3700
6800
7280
14150
19420
22500
Pa
726
574
650
549
539
667
230
3,9
7,3
12,1
14,3
24,2
30,8
32,2
49,5
62,4
Compressor frequency : 30 Hz
Total cooling capacity
kW
(1)
1,00
Compressor frequency : 70 Hz
Total cooling capacity
kW
(1)
6,6
8,6
16,9
23,9
1,00
kW
(1)
Height
Width
mm
Depth
24,4
34,6
46,3
68,6
85,5
0,89
0,94
0,95
0,84
0,99
0,93
1 x Scroll
2 x Scroll
1875
1875
1998
1998
1998
1998
1998
600
900
1010
1280
2030
2510
2510
600
600
795
795
795
795
950
kg
157
230
375
605
632
979
1013
dB(A)
49
53
55
58
65
66
61
Weight
(2)
12,3
1 x Twin-Rotary
EC motor compressors
9,3
(2) At 1,5 meter height, 2 meters frontal distance in free field down flow
units (30 Pa AESP), nominal airflow rate, cp speed 50Hz
GC15-E_V1
171
R@CKCOOLAIR
DX : 3 49 kW
CW : 20 74 kW
Main applications
Medium and small sizes data centers
Computer rooms
General description
Thanks to the R@CKCOOLAIR series, LENNOX offers an ideal solution for cooling of server racks in medium and small sizes
data centres. They are also best suitable for extension of existing sites or in server rooms without raised floor. Its position
next to the heat source guarantees an immediate and efficient reaction to varying heat dissipations from the servers.
Standard features
Spot cooling: where and when you need it
Airflow switch
Full accessibility
172
structure
Two drain pans made of AISI 430 stainless steel EDX
Hydraulic connections from the top or from the bottom
Powder-coated metal sheet structure
Footprint : 300 x 1200 mm or 600 x 1200 mm only
Fully insulated panels
2 or 3 way water valve, modulating by means of a 0-10 V
signal
Display of 3-way water valve mixing percentage
Programmable control with LCD display
Two separate zones control (top and bottom of the unit)
Different airflow configurations
Modulating airflow rate according to the cooling capacity
for a much higher energy saving
Built-in condensing control for air-cooled units (modulating
fan-speed control) with dedicated automatic breaker
Lockable panels
LAN connection up to 8 units
4 alarms with extra potential free contacts
GC15-E_V1
Trend
SNMP
RHC units
Chilled water unit with high performance coil and modulating water valve which distinguishes
for:
Highest specific cooling capacity (W/m2) due to the large heat exchanger surface;
Precise temperature control (PID type regulation);
The possibility to increase return air temperature, thus to rise the medium chilled water
temperature (while keeping the cooling capacity stable). This results in a maximized EER
of the chiller and extends free-cooling operation range.
This is the solution for small and medium size installations where no chilled water system is available or where no chiller can be placed or where site specific constraints do
not allow water in the datacenter. Adjusting the facility configuration with the distance
between indoor and outdoor unit enables a simple and economical installation.
Ventilation
Remote condenser
Condensing unit
Positioning of the R@CKCOOLAIR unit next to the server itself minimizes the ventilation
consumption needed to overcome pressure drops from ducting or raised floor systems.
Using of plug fans with backward curved blades (in contrast to axial fans) particularly
guarantees maximum stability in airflow even in most packed server racks where as the
optionally available EC fans allows efficient modulation of the air volume. The integrated
microprocessor modulates the airflow rate in combination with either the chilled water
valve (on RHC units) or the compressor frequency (on RHD/RHV units) and thus significantly reduces the electrical consumption of the airflow (P= k x [airflow]3).
Alternatively is available the optional automatic airflow control which keeps the airflow constant
in case of variable pressure drops of the system, or the Delta P control for a pressure control
in the cold aisle.
Airflow configuration
No ducting systems or raised floors are necessary, the HRC units simplify the installation of the
system.
Several available configurations fit to all needs of modern data centers such as retrofit/expansion
of existing sites :
In row : (horizontal airflow)
ideal for typical hot aisle/cold aisle applications
GC15-E_V1
173
R@CKCOOLAIR
General Data
RHC : chilled water unit
R@CKCOOLAIR
RHC 0200
RHC 0250
RHC 0450
RHC 0510
24C
50%
30C
35%
35C
26%
24C
50%
30C
35%
35C
26%
24C
50%
30C
35%
35C
26%
24C
50%
30C
35%
35C
26%
12,7
20,1
26,2
17,6
27,7
35,4
30,4
46,2
59,1
36,1
57,0
72,8
12,7
20,1
26,2
17,6
27,7
35,4
30,4
46,2
59,1
36,1
57,0
72,8
(1)
kW
0,4
Voltage
Water flow rate
Airflow rate
Dimensions
Length x Height x Depth
0,7
1,2
1,4
400 V/3 Ph/50 Hz
l/h 2176 3459 4511 3023 4769 6083 5236 7945 10155 6202 9807 12519
m3/h
4000
mm
5300
9000
11000
RHD 0100
RHD 0260
24C
50%
30C
35%
35C
26%
24C
50%
30C
35%
35C
26%
Hz
30
70
120
30
70
120
kW
2,4
7,2
11,9
5,2
19,6
28,3
1
kW
0,6
1,5
3.4
0.8
4.1
7.3
2.8
7,3
16.4
1,3
6.6
11.7
m3/h
700
1600
2700
2500
4075
5000
kW
0,05
0,11
0,20
0,10
0,20
0,60
Voltage
Compressor type
Dimensions
Length x Height x Depth
R@CKCOOLAIR
Indoor operating conditions
Temperature - Relative humidity
Compressor frequency
Total cooling capacity
RHD 0400
RHD 0450
24C
50%
30C
35%
35C
26%
24C
50%
30C
35%
35C
26%
Hz
30
70
120
30
70
120
kW
8.2
31.3
43.3
14,9
37.1
49.0
1
kW
1.3
7.0
12.5
2,2
6,5
14,9
2,1
11,2
20.1
3,6
13,7
23,4
m3/h
4500
7335
9000
4500
7335
9000
kW
0,20
0,70
2,00
0,40
0,70
1,20
Voltage
Compressor type
Dimensions
Length x Height x Depth
174
GC15-E_V1
R@CKCOOLAIR
RNV 0140
RNV 0240
RNV 0330
Indoor unit
Compressor frequency
Total cooling capacity
Hz
30
70
120
30
70
120
30
70
120
kW
4.1
10.2
13.3
5.8
19.4
24.8
8.5
26.8
34.6
0,91
0,89
1550
2527
3100
2650
4328
5300
2650
4320
5300
0.1
0.2
0.3
0.1
0.5
0.8
0.1
0.5
0.8
m3/h
kW
Voltage
Dimensions
Length x Height x Depth
Outdoor unit
Compressor frequency
Compressor absorbed power
Compressor absorbed current
Hz
30
70
120
30
70
120
30
70
120
kW
0.5
1.7
2.9
0.8
4.0
6.9
1.2
6.2
10.3
2.5
8.3
14.0
1.2
6.1
11.1
2.0
9.9
16.6
BLDC
Twin rotary
Compressor type
Condenser airflow rate
m3/h
BLDC
Scroll
6950
9300
16300
61
63
63
46
46
49
100
332
492
GC15-E_V1
175
Controls
176
GC15-E_V1
&
BMS
178
Lennox BMS
179
179
180
181
GC15-E_V1
177
ADALINK II
Main applications
BMS light system
Small installations: up to 16 LENNOX units
Description
ADALINK II is the Lennox solution for HVAC installation
monitoring. It can be connected to different LENNOX units.
As an option, possibility to integrate other communication devices
(energy meters, boilers, lighting...).
ADALINK II can give an overview of the whole site map showing
the status of the different units, zooming on each unit and
allowing the user to graphically change the set-point, the access
to the alarm list, and giving the access to the trend curves.
It is the ideal tool for both genuine users giving access only to
specific set-points of the unit, or maintenance specialists (expert
mode) giving access to all the parameters of the unit.
Easy scheduling and zoning management.
Main features
CL2, CL50 and CL60 compatible.
Unloading function (50% and 100% of capacity).
Compatible with one CL60 Chiller.
Very easy to install, it can be used on any computer through
Direct
connection
on PC,
using any
internet browser
Digital Tablet/Phone
Distant customer,
using internet browser
ADALINK CHILLER
GC15-E_V1
Main applications
LennoxVision
Lennox BMS
One site - Multi protocol
Description
LennoxVision is the Lennox supervision and remote
maintenance system. It can be connected to all the Lennox
units and external components without limit. Real BMS
system gives you access to the variables of all the units and
carries out monitoring, scheduling and energy management.
The LennoxVision software allows you to fully manage the
different units on the site : unit, service, alarm, curves and
scheduling screens. The system includes remote connection via modem (options), communication with other BMS,
management of alert messages by SMS or email and lighting
management.
LennoxVision can be used as a local system with mouse,
keyboard and monitor, or as a monitoring
system with access from a remote workstation via modem or network. LennoxVision
includes a complete pre-configured version
of software running on dedicated hardware,
and features all the communication ports
required to best exploit its Web Server and
installation supervision functions.
LennoxOneWeb
LENNOX WEB SERVER
1 SITE - ONLY ONE UNIT
FEATURES
Web page (animated gif)
Time scheduler (weekly basis)
Parameters access
Software upgrade
Alarm alerts (mailing)
Trends
Ethernet connexion
GC15-E_V1
179
179
LennoxCloud
Lennox web portal
Multi sites - Multi units
Main applications
Cloud storage
Remote monitoring
General description
LennoxCloud remotely tracks the units operation on the
customer site.
Through LennoxCloud, the unit can be remotely controlled,
adjusted, or diagnosed by our experts.
LennoxCloud can check (live data trends), optimize (store data
analysis) and troubleshoot (alarm/alert reports) customer
units.
LennoxCloud allows significant energy savings optimizing
performances during all the units life cycle.
Alarm
manager
Owner website
180
180
GC15-E_V1
Main applications
Fan coils and chillers control
Small and medium-size applications for offices
LennoxHydroControl
Lennox HVAC hydronic system
Fan coils and chillers control
Description
LennoxHydroControl is the smartest solution for hydronic
systems: it manages and coordinates cooling and heating
production (chiller/heat-pump units) through fancoils. It
ensures customer comfort, providing important energy
savings through building zoning, time scheduling and set
points, something which is not possible in the other standard
stand-alone systems.
LennoxHydroControl is available for all hydronic installations
(cooling only, heating only, reversible system).
LennoxHydroControl is optimized for small and medium
size applications and especially designed to fulfill RT2012
specifications for offices.
LennoxHydroControl manages up to 8 zones for fancoils and
one for chiller/heatpump.
GC15-E_V1
181
181
lennoxemeia.com
SALES OFFICES :
BELGIUM AND LUXEMBOURG
+ 32 3 633 3045
FRANCE
+33 1 64 76 23 23
GERMANY
+49 (0) 211 950 79 600
ITALY
+ 39 02 495 26 200
RUSSIA
+7 495 626 56 53
SPAIN
+34 915 401 810
UKRAINE
+380 44 585 59 10
NETHERLANDS
+ 31 332 471 800
POLAND
+48 22 58 48 610
PORTUGAL
+351 229 066 050
OTHER COUNTRIES :
LENNOX DISTRIBUTION
+33 4 72 23 20 20
GC15-E_V1