Advanced solution for utilities

Testing of inductive and


electronic single-phase and
three-phase electricity
meters
Accuracy class 0,5s
Energy quality monitoring
features

Data transmitting to PC
Configurable by built-in
keypad or PC
Easy and simple
transportation

Easily changeable current


clamp from 100A to 1500A
Registering of measuring
units profiles
Up to 256 records of testing
results

PTD-3G
portable meter testing device

PTD - 3G (Portable Testing Device) is a portable electronic device for on site meter testing,
measurement of instantaneous values and profile recording. The device also provides some features of
network quality monitoring. It is suitable for testing of single-phase and three-phase electricity meters on
site, for energy quality and network parameters monitoring.
Wide range of functions, user - friendly interface, and sizeable graphical LCD applicable for diagram
indication make the working with this device easy, accurate and attractive.

Application
On site testing of inductive and electronic singlephase and three-phase electricity meters
Power quality monitoring (according to the
standard IEC50160)
Measurement of instantaneous values
Profile recording

Features
Powered by measuring circuits
Wide current measuring range (500mA ... 1500A)
Sizeable graphical LCD indicator (128x128 dots)
with backlight
Electronic test output
RS 232 or USB interface for connection to PC
Current loop interface according to IEC62056-31
for connection to AMR system

Data storage
Up to 64 records of on site meter testing results.
Each record can include up to 4 test results (if all
tests were performed by one request)
Up to 32 records of energy quality monitoring.
Each record includes information about voltage,
frequency variations
Up to 64 snapshots of instantaneous values
(including vector diagram and harmonics)
Recording of up to 6 profiles for chosen
measuring values with measurement period
from 10 s to 60 min.

Functions
Active, reactive and apparent energy measurement with error calculation (percentage):
Measurement error of active energy (cos=1):

0,5 % with clamps A (0,5...100 A);


0,5 % with clamps B (1...1000 A);
0,5 % with clamps C (10...1500 A).

Active, reactive and apparent energy measurement with start / stop function.
Meter accuracy, constant, wiring, no load/start condition testing.
Active, reactive, apparent power measurement (per phase and aggregate):
Measurement error:

0,5 % with clamps A (0,5...100 A);


0,5 % with clamps B (1...1000 A);
0,5 % with clamps C (10...1500 A).

Current measurement:
Frequency range: 45...65 Hz;
Current range: depends on current clamps;
Measurement error:

0,5 % with clamps A (0,5...100 A);


0,2 % with clamps B (1...1000 A);
0,5 % with clamps C (10...1500 A).

Voltage measurement:
Frequency range: 45...65 Hz;
Error: 0,2 % in range 50 ...265 V.
Power factor measurement (per phase and aggregate):
Measurement range -1...+1;
Resolution: 0,01.
Frequency measurement:
Range 45...65 Hz;
Resolution 0,01 Hz.
Harmonics analysis:
Harmonic components from 2 to 30 in - percent of the fundamental wave;
Numeric values of each harmonic component;
Chart in a logarithmic scale.
Vector diagram displaying.
Measurement of angles:
Voltage phase shift angles (per phase and aggregate), resolution: 0,1;
Angles between voltage phases, resolution: 1.
Power quality measurement:
Voltage variation measurement (according En50160);
Frequency variation measurement (according En50160);
Total harmonics distortion;
Power outages.

Technical specifications
Power supply
Powered by voltage measuring circuits

45 V... 276 V, consumption: < 2 W per phase

Powered by auxiliary circuit

45 V... 276 V, consumption: < 6 W

Profiles
Number of channels for profile
recording:

6 with 25 different parameters available

One of 5 registration algorithms for


each channel:

Minimum value per measurement period


Maximum value per measurement period
Average value per measurement period
Snapshot at the end of measurement period
Standard deviation per measurement period

Range of measurement period:

10s...60 min

Current clamps
Current range 0,5 A...100 A (Clamps A)
Electrical safety:
Insulation:
Pollution:
Safety class:
Operating voltage:
Bare conductor
Isolated conductor

30V
600V

Overload:

170 A

Protection level:

IP 40

Dual
Level 2
Class III

Current range 1 A...1000 A (Clamps B)


Electrical safety:
Insulation:
Pollution:
Safety class:
Operating voltage:

Dual
Level 2
Class III
600V

Overload:

1200 A

Protection level:

IP 40

Current range 10 A...1500 A (Clamps C)


Electrical safety:
Insulation:
Pollution:
Safety class:
Operating voltage:
Bare conductor
Isolated conductor

600V,
1000V

Overload:

1800 A

Protection level:

IP 20

Dual
Level 2
Class III

Scanning head
Usable with:

Induction and electronic meters

Supply voltage:

6...12 V

Dimensions:

270mm x 95mm x 80mm

Hard plastic

Dimension:

157 x 189 x 67 mm

Weight:

0.8 kg

Operation temperature:

-20 C ... + 50 C

Protection level:

IP 40

at

ional C
er

at

ional C
er

fic

fic

CERT

ISO 9001:2008
15 100 8380

ISO 14001:2004
15 104 2060

TIC

TIC

ation

ation

CERT

rn

ti

rn

ti

ELGAMA-ELEKTRONIKA
Visoriu st. 2. 08300 Vilnius, Lithuania
Phone: +370 5 2375009
Fax: +370 5 2375020
e-mail: marketing@elgama.eu
www.elgama.eu

Housing:

TV Int

80
100x 55 or 120 x 45

TV Int

Max. Clamping capacity:


Cable, mm:
Bus bar, mm:

Electronic block

You might also like