Professional Documents
Culture Documents
Page 1/3
November 2004
Characteristics
Application
The converter CRS-50 is used to link an instrument net RS-485 to an
interface RS-232 of the PC.
Electrical test
Test voltage:
UAX = 2060Vca/Vcc = 1,5kV/1 min. 60Hz
between auxiliary power supply and others
Test voltage:
UAX = 85265Vca/90300Vcc = 2,5kV/1 min. 60Hz
Between auxiliary power supply and others
Technical data
Communication
- Baud Rate:
- Flux control:
Power supply
Power consumption:
Influence magnitude
Environment temperature:
External magnetic
Interference
Radio frequency
Interference
Type
Housing
Case
Fastening
Electrical connection
Protection class
Weight
85 265Vca e 90 300Vcc
2060Vca/Vcc
approx 1W.
25C 2K
0,5% for field intensity of
0,4 kA/m
0,5% between 27460MHz
at a distance 1m; power 1 W
Polyamide UL94 VO
Surface mounting using DIN rail
Terminals for pin shaped cable shoes.
IP 40 no housing
IP 20 at the connection terminals
0,1 kg
Climatic conditions
Operation temperature
Functioning temperature
Transport and storage temp.
Relative humidity
Mechanical test
Impact
Vibration
-20...+60C
-25...+70C
-40...+80C
75% of annual average with
light condensation
(others on consult)
Converter CRS-50
Electric connection
Page 2/3
November 2004
Additional Information
Cautions
Uax=Power supply
Connector DB9 connected to PC
Mounting Instructions
Dimensional
Dimensions in mm
For mounting on DIN rail, use the snap-in device on the rear of the
instrument.
The connections can be made with pin for shaped cable shoes.
Converter CRS-50
Page 3/3
November 2004
Code structure
Catalog n
CONVERTER RS232/485 CRS-50
Power Supply
2060Vca/Vcc
85265Vca e 90300Vcc
12
13
Additional information
Normal
Complement
1
C
Example of specification
Converter RS232/RS485 CRS-50