You are on page 1of 79

CAPACITIVE LOAD BANKS FOR POWER FACTOR CORRECTION WITH

AUTOMATIC AND MANUAL MODE SETTING


ABSTRACT
The Purpose of this paper is implementing a new technology for power factor improvement of 3
phase induction motor as well as for single phase induction motor , as improvement of power
factor is necessary for industrial as well as domestic areas & to make power factor as close as
unity without facing penalty from electrical distributers. As we know in industries most of motor
which is usually used is induction motor and induction motor having low power factor also.
Home appliances which are generally used are generally having low power factor. Hence there is
need of power factor improvement in case of household appliances as well as in industrial
purpose. Induction motor is most widely used motors in industries .As name of this motor
specifies this motor having low power factor. Hence there is need of power factor improvement.
The power factor correction of electrical loads is a problem common to all industrial companies.
Earlier the power factor correction was done by adjusting the capacitive bank manually [1]. The
automated power factor corrector (APFC) using capacitive load bank is helpful in providing the
power factor correction. Proposed automated project involves measuring the power factor value
from the load using microcontroller. The design of this auto-adjustable power factor correction is
to ensure the entire power system always preserving unity power factor. The software and
hardware required to implement the suggested automatic power factor correction scheme are
explained and its operation is described. APFC thus helps us to decrease the time taken to correct
the power factor which helps to increase the efficiency. In a purely resistive ac circuit, voltage
and current waveforms are in phase, changing polarity at the same instant in each cycle. Where
reactive loads are present, such as with capacitors or inductors, energy storage in the loads result
in a time difference between the current and voltage waveforms. This stored energy returns to the
source and is not available to do work at the load. a circuit with a low power factor will have
thus higher currents to transfer a given quantity of real power than a circuit with a high power
factor.

INTRODUCTION
An embedded system is a combination of software and hardware to perform a
dedicated task.

Some

of the

main

devices

used in

embedded

products

are Microprocessorsand Microcontrollers. Microprocessors are commonly referred to a


s general purpose processors as they simply accept the inputs, process it and give the output.
In contrast, a microcontroller not only accepts the data as inputs but also manipulates it,
interfaces the data with various devices, controls the data and thus finally gives the result. Majority of the
loads in the industries are highly inductive in nature such as induction motors, AC/DC drives,
welding machines, arc furnaces, fluorescent Lightings, electronic controls and computers. There
may be a few resistive loads for heaters and incandescent bulbs. Very rarely industries may have
capacitive loads such as synchronous motors . Net industrial load is highly inductive causing a
very poor lagging power factor. If this poor power factor is left uncorrected, the industry will
require a high maximum demand from Electricity Board and also will suffer a penalty for poor
power factor. Standard practice is to connect power capacitors in the power system at appropriate
places to compensate the inductive nature of the load. Any motor that operates on alternating
current requires apparent power, but apparent power is addition of active power and reactive
power. Active power is the power which is actually consumed by the load. Reactive power is the
power demanded by the load and returned to the power source. The simplest way to specify
power factor is POWER FACTOR is the ratio between the useful (true) power whose unit is
KW to the total (apparent) power whose unit is KVA consumed by an A.C electrical equipment
or motor. Power factor is a measure of how effectively electrical power is used to perform an
useful work. The ideal power factor is unity or one. If power factor is less than one it means that
excess power is required to perform or achieve the actual work.

LITERATURE SURVEY
An electrical load that operates on alternating current requires apparent power, which consists of
real power plus reactive power. Real power is the power actually consumed by the load. Reactive
power is repeatedly demanded by the load and returned to the power source, and it is the cyclical
effect that occurs when alternating current passes through a load that contains a reactive
component. The presence of reactive power causes the real power to be less than the apparent
power, and so, the electric load has a power factor of less than 1. The reactive power increases
the current flowing between the power source and the load, which increases the power losses
through transmission and distribution lines. This results in operational and financial losses for
power companies.
OBJECTIVES
The aim of this project is to find a good solution to high energy consumption by industries,
through a sustainable development of automatic system that corrects low power factor. The
advantages of correcting power factor reduced demand charges, increased load carrying
capabilities in existing circuits, improved voltage and reduced power system loses. Specific
Objectives 5 In light of the above objective, specific objectives of the study are as follows:
Develop a prototype of an automatic power factor corrector with microcontroller as the brain of
the control system. The overall purpose is to improve low power factor, improve energy
consumption by industries, improve stability and efficiency of the transmission network.
Though correction of power factor is very old practice, we have considered the work done in
recent years in our Thesis. Many of the authors below have suggested and prescribe many ways
of power factor correction but this work concentrates on Barsoum model: We have considered
the work done in the previous years, starting from 1988. Sharkawi et al. proposed a continuing
effort to develop an effective, reliable, and inexpensive adaptive power factor controller (APFC).
The APFC was able to compensate adaptively the reactive power of rapidly varying loads
without adding harmonics or transients to the power system. Based on thousands of hours of
field operation, the APFC had substantially modified to improve its reliability and effectiveness.
(Sharkawi et al. 1988)

METHODOLOGY
The aim is to monitor the power factor continuously and in the event of change in power factor,
which usually result in the demand of higher current a correction action is initialized to
compensate for this difference by continuous changing variable capacitors value through
switching process. The overall system requires only one PIC chip, a few power electronic
components and bank of capacitors.

BLOCK DIAGRAM

DESCRIPTION
This project provides continuous power factor correction using capacitive bank loading. Power
factor is a measure of how effectively you are using electricity. Various types of power are at
work to provide us with electrical energy. Improving the PF can maximize current-carrying
capacity, improve voltage to equipment, reduce power losses, and lower electric bills. The
simplest way to improve power factor is to add PF correction capacitors to the electrical system.
PF correction capacitors act as reactive current generators. They help offset the non-working
power used by inductive loads, thereby improving the power factor. The interaction between PF
capacitors and specialized equipment, such as variable speed drives, requires a well designed
system.
PF correction capacitors can switch on every day when the inductive equipment starts. The most
practical and economical power factor correction device is the capacitor. It improves the power
factor because the effects of capacitance are exactly opposite from those of inductance.
In this project, the capacitors can be connected using manual switches in manual operation mode.
In automatic mode, the capacitors are connected through electromagnetic relay with predefined
time delay to demonstrate the power factor correction practically.

AT89S52 MCU is used to control the switching relays. 16X2 alphanumeric LCD is used to
display the status. This project uses regulated 5V, 750mA power supply. 7805 three terminal
voltage regulator is used for voltage regulation. Bridge type full wave rectifier is used to rectify
the ac output of secondary of 230/12V step down transformer.

The power factor of an ac electric power system is defined as the ratio of the real power to the
apparent power, and is a number between 0 and 1. Real power is the capacity of the electric load
for performing work in a particular time. Apparent power is the product of the current and
voltage of the electric load. Due to energy stored in the load and returned to the source, or due to
a non-linear load that distorts the wave shape of the current drawn from the source, the apparent

power can be greater than the real power. Low-power-factor loads increase losses in a power
distribution system and result in increased energy costs.

Power Factor Power factor is an energy concept that is related to power flow in electrical
systems. To understand power factor, it is helpful to understand three different types of power in
electrical systems. Real Power is the power that is actually converted into useful work for
creating heat, light and motion. Real power is measured in kilowatts (kW)q and is totalized by
the electric billing meter in kilowatt-hours (kWH). An example of real power is the useful work
that directly turns the shaft of a motor. Reactive Power is the power used to sustain the
electromagnetic field in inductive and capacitive equipment. It is the non- working power
component. Reactive power is measured in kilovolt-amperes reactive (kVAR). Reactive power
does not appear on the customer billing statement. Total Power or Apparent power is the
combination of real power and reactive power. Total power is measured in kilovolt-amperes
(kVA) and is totalized by the electric billing meter in kilovolt-ampere-hours (kVAH). Power
factor (PF) is defined as the ratio of real power to total power, and is expressed as a percentage
(%). Power factor = Real Power (kWH) Total Power (kVAH) x 100.

Power Factor Correction Power factor correction is the process of compensating for the lagging
current by creating a leading current by connecting capacitors to the supply. A sufficient
capacitance can be connected so that the power factor is adjusted to be as close to unity as
possible. Power factor correction (PFC) is a system of counteracting the undesirable effects of
electric loads that create a power factor that is less than one (1). Power factor correction may be
applied either by an electrical power transmission utility to improve the stability and efficiency
of the transmission network or, correction may be installed by individual electrical customers to
reduce the costs charged to them by their electricity service provider .

An electrical load that operates on alternating current requires apparent power, which consists of
real power and reactive power. Real power is the power actually consumed by the load. Reactive
power is repeatedly demanded by the load and returned to the power source, and it is the cyclical
effect that occurs when alternating current passes through a load that contains a reactive
component. The presence of reactive power causes the real power to be less than the apparent
power, so the electric load has a power factor of less than one. The reactive power increases the
current flowing between the power source and the load, which increases the power losses
through transmission and distribution lines. This results in operational and financial losses for
power companies. Therefore, power companies require their customers, especially those with
large loads, to maintain their power factors above a specified amount especially around ally 0.90
or higher, or be subject to additional charges. Electrical engineers involved with the generation,
transmission, distribution and consumption of electrical power have an interest in the power
factor of loads because power factors affect efficiencies and costs for both the electrical power
industry and the consumers. In addition to the increased operating costs, reactive power can
require the use of wiring, switches, circuit breakers, transformers and transmission lines with
higher current capacities.

Capacitor A capacitor (originally known as condenser) is a passive two-terminal electrical


component used to store energy in an electric field. The forms of practical capacitors vary
widely, but all contain at least two electrical conductors separated by a dielectric (insulator); for
example, one common construction consists of metal foils separated by a thin layer of insulating
film. Capacitors are widely used as parts of electrical circuits in many common electrical
devices. When there is a potential difference (voltage) across the conductors, a static electric
field develops across the dielectric, causing positive charge to collect on one plate and 24
negative charge on the other plate. Energy is stored in the electrostatic field. An ideal capacitor is
characterized by a single constant value, capacitance, measured in farads. This is the ratio of the
electric charge on each conductor to the potential difference between them. The capacitance is
greatest when there is a narrow separation between large areas of conductor; hence capacitor
conductors are often called plates, referring to an early means of construction. In practice, the
dielectric between the plates passes a small amount of leakage current and also has an electric

field strength limit, resulting in a breakdown voltage, while the conductors and leads introduce
an undesired inductance and resistance. Capacitors are widely used in electronic circuits for
blocking direct current while allowing alternating current to pass, in filter networks, for
smoothing the output of power supplies, in the resonant circuits that tune radios to particular
frequencies, in electric power transmission systems for stabilizing voltage and power flow, and
for many other purposes. Capacitors also require reactive power to operate. However, capacitors
and inductors have an opposite affect on reactive power. The power factors for capacitors are
leading. Therefore capacitors are installed to counteract the effect of reactive power used by
inductive equipment. (Hammond, P 1964).
Uses of Automatic Power Factor Capacitors
When the load conditions and power factor in a facility change frequently, the demand for power
factor improving capacitors also changes frequently. In order to assure that the proper amount of
power factor capacitor kVARs are always connected to the system (without over-correcting), an
Automatic Type Capacitor System should be used for applications involving multiple loads. A
microcontroller automatic compensation system is formed by: 26 Some sensors detecting
current and voltage signals; An intelligent unit that compares the measured power factor with
the desired one and operates the connection and disconnection of the capacitor banks with the
necessary reactive power (power factor regulator); An electric power board comprising
switching and protection devices; Some capacitor banks.

Potential Sources of Harmonics


Switched mode power supplies
Dimmers
Current Regulators
Frequency Converters.
Voltage source inverters with pulse width modulated converters.

Low power consumption lamps.


Electrical arc-furnaces.
Arc welding machines.
Induction motors with irregular magnetizing current associated with saturation of the iron.
All equipment with built-in switching devices or with internal loads with nonlinear
voltage/current characteristics.

HARDWARE REQUIREMENT
AT89S52 MICROCONTROLLER
MICROCONTROLLERS:
Microprocessors and microcontrollers are widely used in embedded systems
products. Microcontroller is a programmable device. A microcontroller has a CPU in addition to
a fixed amount of RAM, ROM, I/O ports and a timer embedded all on a single chip. The fixed
amount of on-chip ROM, RAM and number of I/O ports in microcontrollers makes them ideal
for many applications in which cost and space are critical.
The Intel 8052 is Harvard architecture, single chip microcontroller (C) which was
developed by Intel in 1980 for use in embedded systems. It was popular in the 1980s and early
1990s, but today it has largely been superseded by a vast range of enhanced devices with 8052compatible processor cores that are manufactured by more than 20 independent manufacturers
including Atmel, Infineon Technologies and Maxim Integrated Products.
8052 is an 8-bit processor, meaning that the CPU can work on only 8 bits of data at a
time. Data larger than 8 bits has to be broken into 8-bit pieces to be processed by the CPU. 8052
is available in different memory types such as UV-EPROM, Flash and NV-RAM.
The present project is implemented on Keil uVision. In order to program the device,
proload tool has been used to burn the program onto the microcontroller.
The features, pin description of the microcontroller and the software tools used are
discussed in the following sections.

FEATURES
8K Bytes of In-System Programmable (ISP) Flash Memory
4.0V to 5.5V Operating Range
Fully Static Operation: 0 Hz to 33 MHz
256 x 8-bit Internal RAM
32 Programmable I/O Lines
Three 16-bit Timer/Counters
Full Duplex UART Serial Channel
Low-power Idle and Power-down Modes
Interrupt Recovery from Power-down Mode
Watchdog Timer
Dual Data Pointer
Power-off Flag

DESCRIPTION

The AT89S52 is a low-power, high-performance CMOS 8-bit microcontroller with 8K


bytes of in-system programmable Flash memory. The device is manufactured using Atmels
high-density nonvolatile memory technology and is compatible with the industry- standard
80C51 instruction set and pinout. The on-chip Flash allows the program memory to be
reprogrammed in-system or by a conventional nonvolatile memory programmer. By combining a
versatile 8-bit CPU with in-system programmable Flash on a monolithic chip, the Atmel
AT89S52 is a powerful microcontroller which provides a highly-flexible and cost-effective
solution to many embedded control applications.

The AT89S52 provides the following standard features: 8K bytes of Flash, 256 bytes of
RAM, 32 I/O lines, Watchdog timer, two data pointers, three 16-bit timer/counters, a six-vector
two-level interrupt architecture, a full duplex serial port, on-chip oscillator, and clock circuitry.
In addition, the AT89S52 is designed with static logic for operation down to zero frequency and
supports two software selectable power saving modes.

The Idle Mode stops the CPU while allowing the RAM, timer/counters, serial port, and
interrupt system to continue functioning. The Power-down mode saves the RAM contents but
freezes the oscillator, disabling all other chip functions until the next interrupt or hardware reset.

PIN CONFIGURATIONS

PIN DESCRIPTION

VCC
Supply voltage.

GND
Ground.

Port 0
Port 0 is an 8-bit open drain bidirectional I/O port. As an output port, each pin can sink eight
TTL inputs. When 1s are written to port 0 pins, the pins can be used as high impedance inputs.
Port 0 can also be configured to be the multiplexed low order address/data bus during accesses to
external program and data memory. In this mode, P0 has internal pullups. Port 0 also receives the
code bytes during Flash programming and outputs the code bytes during program verification.
External pullups are required during program verification.

Port 1
Port 1 is an 8-bit bidirectional I/O port with internal pullups. The Port 1 output buffers can
sink/source four TTL inputs. When 1s are written to Port 1 pins, they are pulled high by the
internal pullups and can be used as inputs. As inputs, Port 1 pins that are externally being pulled
low will source current (IIL) because of the internal pullups. In addition, P1.0 and P1.1 can be
configured to be the timer/counter 2 external count input (P1.0/T2) and the timer/counter 2
trigger input (P1.1/T2EX), respectively, as shown in the following table. Port 1 also receives the
low-order address bytes during Flash programming and verification.

Port 2
Port 2 is an 8-bit bidirectional I/O port with internal pullups. The Port 2 output buffers can
sink/source four TTL inputs. When 1s are written to Port 2 pins, they are pulled high by the
internal pullups and can be used as inputs. As inputs, Port 2 pins that are externally being pulled
low will source current (IIL) because of the internal pullups. Port 2 emits the high-order address
byte during fetches from external program memory and during accesses to external data memory
that use 16-bit addresses (MOVX @ DPTR). In this application, Port 2 uses strong internal pullups when emitting 1s. During accesses to external data memory that use 8-bit addresses (MOVX
@ RI), Port 2 emits the contents of the P2 Special Function Register. Port 2 also receives the
high-order address bits and some control signals during Flash programming and verification.

Port 3
Port 3 is an 8-bit bidirectional I/O port with internal pullups. The Port 3 output buffers can
sink/source four TTL inputs. When 1s are written to Port 3 pins, they are pulled high by the
internal pullups and can be used as inputs. As inputs, Port 3 pins that are externally being pulled
low will source current (IIL) because of the pullups. Port 3 also serves the functions of various
special features of the AT89S52, as shown in the following table. Port 3 also receives some
control signals for Flash programming and verification.

RST
Reset input. A high on this pin for two machine cycles while the oscillator is running resets the
device. This pin drives High for 96 oscillator periods after the Watchdog times out. The DISRTO
bit in SFR AUXR (address 8EH) can be used to disable this feature. In the default state of bit
DISRTO, the RESET HIGH out feature is enabled.

ALE/PROG
Address Latch Enable (ALE) is an output pulse for latching the low byte of the address during
accesses to external memory. This pin is also the program pulse input (PROG) during Flash
programming. In normal operation, ALE is emitted at a constant rate of 1/6 the oscillator
frequency and may be used for external timing or clocking purposes. Note, however, that one
ALE pulse is skipped during each access to external data memory. If desired, ALE operation can
be disabled by setting bit 0 of SFR location 8EH. With the bit set, ALE is active only during a
MOVX or MOVC instruction. Otherwise, the pin is weakly pulled high. Setting the ALE-disable
bit has no effect if the microcontroller is in external execution mode.

PSEN
Program Store Enable (PSEN) is the read strobe to external program memory. When the
AT89S52 is executing code from external program memory, PSEN is activated twice each
machine cycle, except that two PSEN activations are skipped during each access to external data
memory.

EA/VPP
External Access Enable. EA must be strapped to GND in order to enable the device to fetch code
from external program memory locations starting at 0000H up to FFFFH. Note, however, that if
lock bit 1 is programmed, EA will be internally latched on reset.
EA should be strapped to VCC for internal program executions. This pin also receives the 12volt programming enable voltage (VPP) during Flash programming.

XTAL1
Input to the inverting oscillator amplifier and input to the internal clock operating circuit.

XTAL2
Output from the inverting oscillator amplifier.

XTAL1 and XTAL2 are the input and output, respectively, of an inverting amplifier that can be
configured for use as an on-chip oscillator, as shown in Figure. Either a quartz crystal or ceramic
resonator may be used. To drive the device from an external clock source, XTAL2 should be left
unconnected while XTAL1 is driven, as shown in the below figure. There are no requirements on
the duty cycle of the external clock signal, since the input to the internal clocking circuitry is

through a divide-by-two flip-flop, but minimum and maximum voltage high and low time
specifications must be observed.

Fig: Oscillator Connections

C1, C2 = 30 pF 10 pF for Crystals


= 40 pF 10 pF for Ceramic Resonators

Fig: External Clock Drive Configuration

8052 MICROCONTROLLER MEMORY ORGANIZATION


The microcontroller memory is divided into Program Memory and Data Memory. Program
Memory (ROM) is used for permanent saving program being executed, while Data Memory
(RAM) is used for temporarily storing and keeping intermediate results and variables. Depending
on the model in use (still referring to the whole 8052 microcontroller family) at most a few Kb of
ROM and 128 or 256 bytes of RAM can be used. However
All 8052 microcontrollers have 16-bit addressing bus and can address 64 kb memory. It is neither
a mistake nor a big ambition of engineers who were working on basic core development. It is a
matter of very clever memory organization which makes these controllers a real programmers
tidbit.
Program Memory
The oldest models of the 8052 microcontroller family did not have any internal program
memory. It was added from outside as a separate chip. These models are recognizable by their
label beginning with 803 (for ex. 8031 or 8032). All later models have a few Kbytes ROM
embedded, Even though it is enough for writing most of the programs, there are situations when
additional memory is necessary. A typical example of it is the use of so called lookup tables.
They are used in cases when something is too complicated or when there is no time for solving
equations describing some process. The example of it can be totally exotic (an estimate of self-

guided rockets meeting point) or totally common (measuring of temperature using non-linear
thermo element or asynchronous motor speed control). In those cases all needed estimates and
approximates are executed in advance and the final results are put in the tables (similar to
logarithmic tables).

How does the microcontroller handle external memory depend on the pin EA logic state?

EA=0 In this case, internal program memory is completely ignored, only a program stored in
external memory is to be executed.
EA=1 In this case, a program from built-in ROM is to be executed first (to the last location).
Afterwards, the execution is continued by reading additional memory.
in both cases, P0 and P2 are not available to the user because they are used for data and address
transmission. Besides, the pins ALE and PSEN are used too.

Data Memory
As already mentioned, Data Memory is used for temporarily storing and keeping data and
intermediate results created and used during microcontrollers operating. Besides, this
microcontroller family includes many other registers such as: hardware counters and timers,
input/output ports, serial data buffers etc. The previous versions have the total memory size of
256 locations, while for later models this number is incremented by additional 128 available
registers. In both cases, these first 256 memory locations (addresses 0-FFh) are the base of the
memory. Common to all types of the 8052 microcontrollers. Locations available to the user
occupy memory space with addresses from 0 to 7Fh. First 128 registers and this part of RAM is
divided in several blocks.
The first block consists of 4 banks each including 8 registers designated as R0 to R7. Prior to
access them, a bank containing that register must be selected. Next memory block (in the range
of 20h to 2Fh) is bit- addressable, which means that each bit being there has its own address
from 0 to 7Fh. Since there are 16 such registers, this block contains in total of 128 bits with
separate addresses (The 0th bit of the 20h byte has the bit address 0 and the 7th bit of the 2Fh
byte has the bit address 7Fh). The third groups of registers occupy addresses 2Fh-7Fh (in total of
80 locations) and does not have any special purpose or feature.
Additional Memory Block of Data Memory
In order to satisfy the programmers permanent hunger for Data Memory, producers have
embedded an additional memory block of 128 locations into the latest versions of the 8052
microcontrollers. Naturally, its not so simpleThe problem is that electronics performing
addressing has 1 byte (8 bits) on disposal and due to that it can reach only the first 256 locations.
In order to keep already existing 8-bit architecture and compatibility with other existing models a
little trick has been used.
Using trick in this case means that additional memory block shares the same addresses with
existing locations intended for the SFRs (80h- FFh). In order to differentiate between these two
physically separated memory spaces, different ways of addressing are used. A direct addressing
is used for all locations in the SFRs, while the locations from additional RAM are accessible
using indirect addressing.

Fig: Microcontroller internal structure

How to extend memory?


In case on-chip memory is not enough, it is possible to add two external memory chips with
capacity of 64Kb each. I/O ports P2 and P3 are used for their addressing and data transmission.

From the users perspective, everything functions quite simple if properly connected because the
most operations are performed by the microcontroller itself. The 8052 microcontroller has two
separate reading signals RD#(P3.7) and PSEN#. The first one is activated byte from external data
memory (RAM) should be read, while another one is activated to read byte from external
program memory (ROM). These both signals are active at logical zero (0) level. A typical

example of such memory extension using special chips for RAM and ROM is shown on the
previous picture. It is called Hardward architecture.
Even though the additional memory is rarely used with the latest versions of the
microcontrollers, it will be described here in short what happens when memory chips are
connected according to the previous scheme. It is important to know that the whole process is
performed automatically, i.e. with no intervention in the program.

When the program during execution encounters the instruction which resides in external
memory (ROM), the microcontroller will activate its control output ALE and set the first
8 bits of address (A0-A7) on P0. In this way, IC circuit 74HCT573 which "lets in" the
first 8 bits to memory address pins is activated.

A signal on the pin ALE closes the IC circuit 74HCT573 and immediately afterwards 8
higher bits of address (A8-A15) appear on the port. In this way, a desired location in
additional program memory is completely addressed. The only thing left over is to read
its content.

Pins on P0 are configured as inputs, the pin PSEN is activated and the microcon troller
reads content from memory chip. The same connections are used both for data and lower
address byte.

Similar occurs when it is a needed to read some location from external Data Memory. Now,
addressing is performed in the same way, while reading or writing is performed via signals which
appear on the control outputs RD or WR.
Addressing
While operating, processor processes data according to the program instructions. Each
instruction consists of two parts. One part describes what should be done and another part
indicates what to use to do it. This later part can be data (binary number) or address where the
data is stored. All 8052 microcontrollers use two ways of addressing depending on which part of
memory should be accessed:

Direct Addressing
On direct addressing, a value is obtained from a memory location while the address of that
location is specified in instruction. Only after that, the instruction can process data (how depends
on the type of instruction: addition, subtraction, copy). Obviously, a number being changed
during operating a variable can reside at that specified address. For example:
Since the address is only one byte in size ( the greatest number is 255), this is how only the first
255 locations in RAM can be accessed in this case the first half of the basic RAM is intended to
be used freely, while another half is reserved for the SFRs.
Indirect Addressing
On indirect addressing, a register which contains address of another register is specified in the
instruction. A value used in operating process resides in that another register. For example:
Only RAM locations available for use are accessed by indirect addressing (never in the SFRs).
For all latest versions of the microcontrollers with additional memory block (those 128 locations
in Data Memory), this is the only way of accessing them. Simply, when during operating, the
instruction including @ sign is encountered and if the specified address is higher than 128 (7F
hex.), the processor knows that indirect addressing is used and jumps over memory space
reserved for the SFRs.
On indirect addressing, the registers R0, R1 or Stack Pointer are used for specifying 8-bit
addresses. Since only 8 bits are available, it is possible to access only registers of internal RAM
in this way (128 locations in former or 256 locations in latest versions of the microcontrollers). If
memory extension in form of additional memory chip is used then the 16-bit DPTR Register
(consisting of the registers DPTRL and DPTRH) is used for specifying addresses. In this way it
is possible to access any location in the range of 64K.

SFRs (Special Function Registers)


SFRs are a kind of control table used for running and monitoring microcontrollers operating.
Each of these registers, even each bit they include, has its name, address in the scope of RAM
and clearly defined purpose ( for example: timer control, interrupt, serial connection etc.). Even
though there are 128 free memory locations intended for their storage, the basic core, shared by
all types of 8052 controllers, has only 21 such registers. Rest of locations are intensionally left
free in order to enable the producers to further improved models keeping at the same time
compatibility with the previous versions. It also enables the use of programs written a long time
ago for the microcontrollers which are out of production now.

Register

(Accumulator)

This is a general-purpose register which serves for storing intermediate results during operating.
A number (an operand) should be added to the accumulator prior to execute an instruction upon
it. Once an arithmetical operation is preformed by the ALU, the result is placed into the
accumulator. If a data should be transferred from one register to another, it must go through
accumulator. For such universal purpose, this is the most commonly used register that none
microcontroller can be imagined without (more than a half 8052 microcontroller's instructions
used use the accumulator in some way).

B Register
B register is used during multiply and divide operations which can be performed only upon

numbers stored in the A and B registers. All other instructions in the program can use this register
as a spare accumulator (A).

During programming, each of registers is called by name so that their exact address is not so
important for the user. During compiling into machine code (series of hexadecimal numbers
recognized as instructions by the microcontroller), PC will automatically, instead of registers
name, write necessary addresses into the microcontroller.

R Registers (R0-R7)

This is a common name for the total 8 general purpose registers (R0, R1, R2 ...R7). Even they
are not true SFRs, they deserve to be discussed here because of their purpose. The bank is active
when the R registers it includes are in use. Similar to the accumulator, they are used for
temporary storing variables and intermediate results. Which of the banks will be active depends
on two bits included in the PSW Register. These registers are stored in four banks in the scope of
RAM.
Description:
The AT89S52 is a low-voltage, high-performance CMOS 8-bit microcomputer with 4K
bytes of Flash programmable memory. The device is manufactured using Atmels high-density
nonvolatile memory technology and is compatible with the industry-standard MCS-51
instruction set. By combining a versatile 8-bit CPU with Flash on a monolithic chip, the Atmel

AT89S52 is a powerful microcomputer, which provides a highly flexible and cost-effective


solution to many embedded control applications.
In addition, the AT89S52 is designed with static logic for operation down to zero
frequency and supports two software selectable power saving modes. The Idle Mode stops the
CPU while allowing the RAM, timer/counters, serial port and interrupt system to continue
functioning. The power-down mode saves the RAM contents but freezes the oscillator disabling
all other chip functions until the next hardware reset.
Machine cycle for the 8052
The CPU takes a certain number of clock cycles to execute an instruction. In the 8052 family,
these clock cycles are referred to as machine cycles. The length of the machine cycle depends on
the frequency of the crystal oscillator. The crystal oscillator, along with on-chip circuitry,
provides the clock source for the 8052 CPU.
The frequency can vary from 4 MHz to 30 MHz, depending upon the chip rating and
manufacturer. But the exact frequency of 11.0592 MHz crystal oscillator is used to make the
8052 based system compatible with the serial port of the IBM PC.
In the original version of 8052, one machine cycle lasts 12 oscillator periods. Therefore, to
calculate the machine cycle for the 8052, the calculation is made as 1/12 of the crystal frequency
and its inverse is taken.

HARDWARE EXPLANATION:
RESISTOR:
Resistors "Resist" the flow of electrical current. The higher the value of resistance (measured
in ohms) the lower the current will be. Resistance is the property of a component which restricts
the flow of electric current. Energy is used up as the voltage across the component drives the
current through it and this energy appears as heat in the component.

Colour Code:

CAPACITOR:
Capacitors store electric charge. They are used with resistors in timing circuits because it
takes time for a capacitor to fill with charge. They are used to smooth varying DC supplies by
acting as a reservoir of charge. They are also used in filter circuits because capacitors easily pass
AC (changing) signals but they block DC (constant) signals.

Circuit symbol:
Electrolytic capacitors are polarized and they must be connected the correct way round, at
least one of their leads will be marked + or -.

Examples:
DIODES:
Diodes allow electricity to flow in only one direction. The arrow of the circuit symbol shows
the direction in which the current can flow. Diodes are the electrical version of a valve and early
diodes were actually called valves.

Circuit symbol:
Diodes must be connected the correct way round, the diagram may be labeled a or + for anode
and k or - for cathode (yes, it really is k, not c, for cathode!). The cathode is marked by a line
painted on the body. Diodes are labeled with their code in

small

print; you may need a magnifying glass to read this on small

signal

diodes.

Example:

LIGHT-EMITTING DIODE (LED):


The longer lead is the anode (+) and the shorter lead is the cathode (&minus). In the schematic
symbol for an LED (bottom), the anode is on the left and the cathode is on the right.
Lighemitting

diodes

are

elements

for

light

signalization

in

electronics.

They are manufactured in different shapes, colors and sizes. For their low price, low
consumption and simple use, they have almost completely pushed aside other light sourcesbulbs at first place.

It is important to know that each diode will be immediately destroyed unless its current is
limited. This means that a conductor must be connected in parallel to a diode. In order to
correctly determine value of this conductor, it is necessary to know diodes voltage drop in
forward direction, which depends on what material a diode is made of and what colors it is.
Values typical for the most frequently used diodes are shown in table below: As seen, there are
three main types of LEDs. Standard ones get full brightness at current of 20mA. Low Current
diodes get full brightness at ten times lower current while Super Bright diodes produce more
intensive light than Standard ones.
Since the 8051 microcontrollers can provide only low input current and since their pins
are configured as outputs when voltage level on them is equal to 0, direct confectioning to LEDs
is carried out as it is shown on figure (Low current LED, cathode is connected to output pin).
Switches and Pushbuttons:
A push button switch is used to either close or open an electrical circuit depending on the
application.

Push

button

switches

are

used

in

various

applications

such

as

industrial equipment control handles, outdoor controls, mobile communication terminals, and
medical equipment, and etc. Push button switches generally include a push button disposed
within a housing. The push button may be depressed to cause movement of the push button
relative to the housing for directly or indirectly changing the state of an electrical contact to open
or close the contact. Also included in a pushbutton switch may be an actuator, driver, or plunger
of some type that is situated within a switch housing having at least two contacts in
communication with an electrical circuit within which the switch is incorporated.

Typical actuators used for contact switches include spring loaded force cap actuators that
reciprocate within a sleeve disposed within the canister. The actuator is typically coupled to the
movement of the cap assembly, such that the actuator translates in a direction that is parallel with
the cap. A push button switch for a data input unit for a mobile communication device such as a
cellular phone, a key board for a personal computer or the like is generally constructed by
mounting a cover member directly on a circuit board. Printed circuit board (PCB) mounted
pushbutton switches are an inexpensive means of providing an operator interface on industrial
control products. In such push button switches, a substrate which includes a plurality of movable
sections is formed of a rubber elastomeric. The key top is formed on a top surface thereof with a
figure, a character or the like by printing, to thereby provide a cover member. Push button
switches incorporating lighted displays have been used in a variety of applications. Such
switches are typically comprised of a pushbutton, an opaque legend plate, and a back light to
illuminate the legend plate.

Block Diagram For Regulated Power Supply (RPS):

Figure: Power Supply

Transformer
A transformer is a device that transfers electrical energy from one circuit to another through
inductively coupled conductorsthe transformer's coils. A varying current in the first or primary
winding creates a varying magnetic flux in the transformer's core, and thus a varying magnetic
field through the secondary winding. This varying magnetic field induces a varying
electromotive force (EMF) or "voltage" in the secondary winding. This effect is called mutual
induction.

Figure: Transformer Symbol


(or)
Transformer is a device that converts the one form energy to another form of energy like a
transducer.

Figure: Transformer

Basic Principle
A transformer makes use of Faraday's law and the ferromagnetic properties of an iron core to
efficiently raise or lower AC voltages. It of course cannot increase power so that if the voltage is
raised, the current is proportionally lowered and vice versa.

Figure: Basic Principle

Transformer Working
A transformer consists of two coils (often called 'windings') linked by an iron core, as shown in
figure below. There is no electrical connection between the coils; instead they are linked by a
magnetic field created in the core.

Figure: Basic Transformer


Transformers are used to convert electricity from one voltage to another with minimal loss of
power. They only work with AC (alternating current) because they require a changing magnetic
field to be created in their core. Transformers can increase voltage (step-up) as well as reduce
voltage (step-down).
Alternating current flowing in the primary (input) coil creates a continually changing magnetic
field in the iron core. This field also passes through the secondary (output) coil and the changing
strength of the magnetic field induces an alternating voltage in the secondary coil. If the
secondary coil is connected to a load the induced voltage will make an induced current flow. The
correct term for the induced voltage is 'induced electromotive force' which is usually abbreviated
to induced e.m.f.
The iron core is laminated to prevent 'eddy currents' flowing in the core. These are currents
produced by the alternating magnetic field inducing a small voltage in the core, just like that
induced in the secondary coil. Eddy currents waste power by needlessly heating up the core but

they are reduced to a negligible amount by laminating the iron because this increases the
electrical resistance of the core without affecting its magnetic properties.
Transformers have two great advantages over other methods of changing voltage:
1

They provide total electrical isolation between the input and output, so they can be safely
used to reduce the high voltage of the mains supply.

Almost no power is wasted in a transformer. They have a high efficiency (power out /
power in) of 95% or more.

Classification of Transformer
Step-Up Transformer
Step-Down Transformer
Step-Down Transformer
Step down transformers are designed to reduce electrical voltage. Their primary voltage is
greater than their secondary voltage. This kind of transformer "steps down" the voltage applied
to it. For instance, a step down transformer is needed to use a 110v product in a country with a
220v supply.
Step down transformers convert electrical voltage from one level or phase configuration usually
down to a lower level. They can include features for electrical isolation, power distribution, and
control and instrumentation applications. Step down transformers typically rely on the principle
of magnetic induction between coils to convert voltage and/or current levels.
Step down transformers are made from two or more coils of insulated wire wound around a core
made of iron. When voltage is applied to one coil (frequently called the primary or input) it
magnetizes the iron core, which induces a voltage in the other coil, (frequently called the
secondary or output). The turns ratio of the two sets of windings determines the amount of
voltage transformation.

Figure: Step-Down Transformer


An example of this would be: 100 turns on the primary and 50 turns on the secondary, a ratio of
2 to 1.
Step down transformers can be considered nothing more than a voltage ratio device.
With step down transformers the voltage ratio between primary and secondary will mirror the
"turns ratio" (except for single phase smaller than 1 kva which have compensated secondary). A
practical application of this 2 to 1 turns ratio would be a 480 to 240 voltage step down. Note that
if the input were 440 volts then the output would be 220 volts. The ratio between input and
output voltage will stay constant. Transformers should not be operated at voltages higher than the
nameplate rating, but may be operated at lower voltages than rated. Because of this it is possible
to do some non-standard applications using standard transformers.
Single phase step down transformers 1 kva and larger may also be reverse connected to stepdown or step-up voltages. (Note: single phase step up or step down transformers sized less than 1
KVA should not be reverse connected because the secondary windings have additional turns to
overcome a voltage drop when the load is applied. If reverse connected, the output voltage will
be less than desired.)
Step-Up Transformer

A step up transformer has more turns of wire on the secondary coil, which makes a larger
induced voltage in the secondary coil. It is called a step up transformer because the voltage
output is larger than the voltage input.
Step-up transformer 110v 220v design is one whose secondary voltage is greater than its primary
voltage. This kind of transformer "steps up" the voltage applied to it. For instance, a step up
transformer is needed to use a 220v product in a country with a 110v supply.
A step up transformer 110v 220v converts alternating current (AC) from one voltage to another
voltage. It has no moving parts and works on a magnetic induction principle; it can be designed
to "step-up" or "step-down" voltage. So a step up transformer increases the voltage and a step
down transformer decreases the voltage.
The primary components for voltage transformation are the step up transformer core and coil.
The insulation is placed between the turns of wire to prevent shorting to one another or to
ground. This is typically comprised of Mylar, nomex, Kraft paper, varnish, or other materials. As
a transformer has no moving parts, it will typically have a life expectancy between 20 and 25
years.

Figure: Step-Up Transformer

Applications:
Generally these Step-Up Transformers are used in industries applications only.
Types of Transformer
Mains Transformers
Mains transformers are the most common type. They are designed to reduce the AC mains

supply voltage (230-240V in the UK or 115-120V in some countries) to a safer low voltage. The
standard mains supply voltages are officially 115V and 230V, but 120V and 240V are the values
usually quoted and the difference is of no significance in most cases.

Figure: Main Transformer


To allow for the two supply voltages mains transformers usually have two separate primary coils
(windings) labeled 0-120V and 0-120V. The two coils are connected in series for 240V (figure
2a) and in parallel for 120V (figure 2b). They must be wired the correct way round as shown in
the diagrams because the coils must be connected in the correct sense (direction):

Most mains transformers have two separate secondary coils (e.g. labeled 0-9V, 0-9V) which may
be used separately to give two independent supplies, or connected in series to create a centretapped coil (see below) or one coil with double the voltage.
Some mains transformers have a centre-tap halfway through the secondary coil and they are
labeled 9-0-9V for example. They can be used to produce full-wave rectified DC with just two
diodes, unlike a standard secondary coil which requires four diodes to produce full-wave
rectified DC.

A mains transformer is specified by:


1

Its secondary (output) voltages Vs.

Its maximum power, Pmax, which the transformer can pass, quoted in VA (volt-amp). This
determines the maximum output (secondary) current, Imax...

...where Vs is the secondary voltage. If there are two secondary coils the maximum
power should be halved to give the maximum for each coil.
3

Its construction - it may be PCB-mounting, chassis mounting (with solder tag


connections) or toroidal (a high quality design).

Audio Transformers
Audio transformers are used to convert the moderate voltage, low current output of an audio
amplifier to the low voltage, high current required by a loudspeaker. This use is called
'impedance matching' because it is matching the high impedance output of the amplifier to the
low impedance of the loudspeaker.

Figure: Audio transformer


Radio Transformers
Radio transformers are used in tuning circuits. They are smaller than mains and audio
transformers and they have adjustable ferrite cores made of iron dust. The ferrite cores can be
adjusted with a non-magnetic plastic tool like a small screwdriver. The whole transformer is
enclosed in an aluminum can which acts as a shield, preventing the transformer radiating too
much electrical noise to other parts of the circuit.

Figure: Radio Transformer

Turns Ratio and Voltage


The ratio of the number of turns on the primary and secondary coils determines the ratio of the
voltages...

...where Vp is the primary (input) voltage, Vs is the secondary (output) voltage, Np is the number
of turns on the primary coil, and Ns is the number of turns on the secondary coil.
Diodes
Diodes allow electricity to flow in only one direction. The arrow of the circuit symbol shows the
direction in which the current can flow. Diodes are the electrical version of a valve and early
diodes were actually called valves.

Figure: Diode Symbol


A diode is a device which only allows current to flow through it in one direction. In this
direction, the diode is said to be 'forward-biased' and the only effect on the signal is that there
will be a voltage loss of around 0.7V. In the opposite direction, the diode is said to be 'reversebiased' and no current will flow through it.
3.2.2 Rectifier

The purpose of a rectifier is to convert an AC waveform into a DC waveform (OR) Rectifier


converts AC current or voltages into DC current or voltage. There are two different rectification
circuits, known as 'half-wave' and 'full-wave' rectifiers. Both use components called diodes to
convert AC into DC.
The Half-wave Rectifier
The half-wave rectifier is the simplest type of rectifier since it only uses one diode, as shown in
figure.

Figure: Half Wave Rectifier


Figure 2 shows the AC input waveform to this circuit and the resulting output. As you can see,
when the AC input is positive, the diode is forward-biased and lets the current through. When
the AC input is negative, the diode is reverse-biased and the diode does not let any current
through, meaning the output is 0V. Because there is a 0.7V voltage loss across the diode, the
peak output voltage will be 0.7V less than Vs.

Figure: Half-Wave Rectification


While the output of the half-wave rectifier is DC (it is all positive), it would not be suitable as a
power supply for a circuit. Firstly, the output voltage continually varies between 0V and Vs0.7V, and secondly, for half the time there is no output at all.
The Full-wave Rectifier
The circuit in figure 3 addresses the second of these problems since at no time is the output
voltage 0V. This time four diodes are arranged so that both the positive and negative parts of the
AC waveform are converted to DC. The resulting waveform is shown in figure 4.

Figure: Full-Wave Rectifier

Figure: Full-Wave Rectification


When the AC input is positive, diodes A and B are forward-biased, while diodes C and D are
reverse-biased. When the AC input is negative, the opposite is true - diodes C and D are
forward-biased, while diodes A and B are reverse-biased.
While the full-wave rectifier is an improvement on the half-wave rectifier, its output still isn't
suitable as a power supply for most circuits since the output voltage still varies between 0V and
Vs-1.4V. So, if you put 12V AC in, you will 10.6V DC out.

Capacitor Filter
The capacitor-input filter, also called "Pi" filter due to its shape that looks like the Greek letter
pi, is a type of electronic filter. Filter circuits are used to remove unwanted or undesired
frequencies from a signal.

Figure: Capacitor Filter


A typical capacitor input filter consists of a filter capacitor C1, connected across the rectifier
output, an inductor L, in series and another filter capacitor connected across the load.
1

The capacitor C1 offers low reactance to the AC component of the rectifier output while
it offers infinite reactance to the DC component. As a result the capacitor shunts an
appreciable amount of the AC component while the DC component continues its journey
to the inductor L

The inductor L offers high reactance to the AC component but it offers almost zero
reactance to the DC component. As a result the DC component flows through the
inductor while the AC component is blocked.

The capacitor C2 bypasses the AC component which the inductor had failed to block. As
a result only the DC component appears across the load RL.

Figure: Centered Tapped Full-Wave Rectifier with a Capacitor Filter


Voltage Regulator
A voltage regulator is an electrical regulator designed to automatically maintain a constant
voltage level. It may use an electromechanical mechanism, or passive or active electronic
components. Depending on the design, it may be used to regulate one or more AC or DC
voltages. There are two types of regulator are they.
Positive Voltage Series (78xx) and
Negative Voltage Series (79xx)
78xx:
78 indicate the positive series and xxindicates the voltage rating. Suppose 7805 produces
the maximum 5V.05indicates the regulator output is 5V.
79xx:
78 indicate the negative series and xxindicates the voltage rating. Suppose 7905
produces the maximum -5V.05indicates the regulator output is -5V.
These regulators consists the three pins there are
Pin1: It is used for input pin.
Pin2: This is ground pin for regulator

Pin3: It is used for output pin. Through this pin we get the output.

Figure: Regulator
LIQUID CRYSTAL DISPLAY:
LCD stands for Liquid Crystal Display. LCD is finding wide spread use replacing LEDs (seven
segment LEDs or other multi segment LEDs) because of the following reasons:
1. The declining prices of LCDs.
2. The ability to display numbers, characters and graphics. This is in contrast to LEDs, which are
limited to numbers and a few characters.
3. Incorporation of a refreshing controller into the LCD, thereby relieving the CPU of the task of
refreshing the LCD. In contrast, the LED must be refreshed by the CPU to keep displaying the
data.
4. Ease of programming for characters and graphics.
These components are specialized for being used with the microcontrollers, which means that
they cannot be activated by standard IC circuits. They are used for writing different messages on
a miniature LCD.

A model described here is for its low price and great possibilities most frequently used in
practice. It is based on the HD44780 microcontroller (Hitachi) and can display messages in two
lines with 16 characters each. It displays all the alphabets, Greek letters, punctuation marks,
mathematical symbols etc. In addition, it is possible to display symbols that user makes up on its

own. Automatic shifting message on display (shift left and right), appearance of the pointer,
backlight etc. are considered as useful characteristics.
Pins Functions
There are pins along one side of the small printed board used for connection to the
microcontroller. There are total of 14 pins marked with numbers (16 in case the background light
is built in). Their function is described in the table below:
Function

Pin Number Name

Logic State Description

Ground

Vss

0V

Power supply

Vdd

+5V

Contrast

Vee

0 - Vdd

Control

of 5

RS

R/W

operating

0
1

D0

D7

are

interpreted

as

commands
D0 D7 are interpreted as data
Write data (from controller to LCD)

Read data (from LCD to controller)

1
From 1 to 0

Data / commands

0
6

D0

0/1

Access
Normal

to

LCD

disabled
operating

Data/commands are transferred to


LCD
Bit 0 LSB

D1

0/1

Bit 1

D2

0/1

Bit 2

10

D3

0/1

Bit 3

11

D4

0/1

Bit 4

12

D5

0/1

Bit 5

13

D6

0/1

Bit 6

14

D7

0/1

Bit 7 MSB

LCD screen:
LCD screen consists of two lines with 16 characters each. Each character consists of 5x7 dot
matrix. Contrast on display depends on the power supply voltage and whether messages are
displayed in one or two lines. For that reason, variable voltage 0-Vdd is applied on pin marked as
Vee. Trimmer potentiometer is usually used for that purpose. Some versions of displays have
built in backlight (blue or green diodes). When used during operating, a resistor for current
limitation should be used (like with any LE diode).

LCD Basic Commands


All data transferred to LCD through outputs D0-D7 will be interpreted as commands or as data,
which depends on logic state on pin RS:
RS = 1 - Bits D0 - D7 are addresses of characters that should be displayed. Built in processor
addresses built in map of characters and displays corresponding symbols. Displaying position
is determined by DDRAM address. This address is either previously defined or the address of
previously transferred character is automatically incremented.
RS = 0 - Bits D0 - D7 are commands which determine display mode. List of commands which
LCD recognizes are given in the table below:

Execution

Command

RS RW D7 D6 D5 D4 D3 D2 D1 D0

Clear display

1.64mS

Cursor home

1.64mS

Entry mode set

I/D S 40uS

Display on/off control

U B 40uS

Cursor/Display Shift

D/C R/L x

Function set

DL N

Set CGRAM address

CGRAM address

Set DDRAM address

DDRAM address

Read BUSY flag (BF)

BF DDRAM address

D7 D6 D5 D4 D3 D2 D1 D0 40uS

D7 D6 D5 D4 D3 D2 D1 D0 40uS

Write

to

CGRAM

or

DDRAM
Read

from

DDRAM

CGRAM

or

Time

40uS

40uS
40uS
40uS
-

I/D 1 = Increment (by 1)


0 = Decrement (by 1)
S 1 = Display shift on
0 = Display shift off
D 1 = Display on
0 = Display off

R/L 1 = Shift right


0 = Shift left
DL 1 = 8-bit interface
0 = 4-bit interface
N 1 = Display in two lines
0 = Display in one line

U 1 = Cursor on

F 1 = Character format 5x10 dots

0 = Cursor off

0 = Character format 5x7 dots

B 1 = Cursor blink on
0 = Cursor blink off

D/C 1 = Display shift


0 = Cursor shift

LCD Initialization:
Once the power supply is turned on, LCD is automatically cleared. This process lasts for
approximately 15mS. After that, display is ready to operate. The mode of operating is set by
default. This means that:
1. Display is cleared
2. Mode
DL = 1 Communication through 8-bit interface
N = 0 Messages are displayed in one line
F = 0 Character font 5 x 8 dots
3. Display/Cursor on/off
D = 0 Display off
U = 0 Cursor off
B = 0 Cursor blink off
4. Character entry
ID = 1 Addresses on display are automatically incremented by 1
S = 0 Display shift off
Automatic reset is mainly performed without any problems. Mainly but not always! If for any
reason power supply voltage does not reach full value in the course of 10mS, display will start
perform completely unpredictably. If voltage supply unit can not meet this condition or if it is
needed to provide completely safe operating, the process of initialization by which a new reset
enabling display to operate normally must be applied. Algorithm according to the initialization is
being performed depends on whether connection to the microcontroller is through 4- or 8-bit
interface. All left over to be done after that is to give basic commands and of course- to display
messages.

Fig: Procedure on 8-bit initialization.

SOFTWARE REQUIREMENT

INTRODUCTION TO KEIL SOFTWARE


ABOUT KEIL:
1

Click on the Keil u Vision4 Icon on Desktop

.The following fig will appear

3. Click on the Project menu from the title bar


4. Then Click on New Project

5. Save the Project by typing suitable project name with no extension in u r own folder
sited in either C:\ or D:\

6
7
8

Then Click on Save button above.


Select the component for u r project. i.e. Atmel
Click on the + Symbol beside of Atmel

Select AT89S52 as shown below

10 Then Click on OK
11 The Following fig will appear

12 Then Click either YES or NOmostly NO


13 Now your project is ready to USE
14 Now double click on the Target1, you would get another option Source group 1 as
shown in next page.

15

Click on the file option from menu bar and select new

16 The next screen will be as shown in next page, and just maximize it by double clicking on
its blue boarder.

17 Now start writing program in either in C or ASM


18 For a program written in Assembly, then save it with extension . asm and for C
based program save it with extension .C

19 Now right click on Source group 1 and click on Add files to Group Source

20. Now you will get another window, on which by default C files will appear.

20 Now select as per your file extension given while saving the file
21 Click only one time on option ADD
22 Now Press function key F7 to compile. Any error will appear if so happen.

23 If the file contains no error, then press Control+F5 simultaneously.

24 The new window is as follows

25 Then Click OK
26 Now Click on the Peripherals from menu bar, and check your required port as shown in
fig below

27 Drag the port a side and click in the program file.

28 Now keep Pressing function key F11 slowly and observe.


29 You are running your program successfully

PROLOAD:
Proload is a software which accepts only hex files. Once the machine code is converted
into hex code, that hex code has to be dumped into the microcontroller placed in the programmer
kit and this is done by the Proload. Programmer kit contains a microcontroller on it other than the
one which is to be programmed. This microcontroller has a program in it written in such a way
that it accepts the hex file from the keil compiler and dumps this hex file into the microcontroller
which is to be programmed. As this programmer kit requires power supply to be operated, this
power supply is given from the power supply circuit designed above. It should be noted that this
programmer kit contains a power supply section in the board itself but in order to switch on that
power supply, a source is required. Thus this is accomplished from the power supply board with
an output of 12volts or from an adapter connected to 230 V AC.
Steps to work with Proload:
1

Install the Proload Software in the PC.

Now connect the Programmer kit to the PC (CPU) through serial cable.

Power up the programmer kit from the ac supply through adapter.

Now place the microcontroller in the GIF socket provided in the programmer kit.

Click on the Proload icon in the PC. A window appears providing the information like
Hardware model, com port, device type, Flash size etc. Click on browse option to select
the hex file to be dumped into the microcontroller and then click on Auto program to
program the microcontroller with that particular hex file.

The status of the microcontroller can be seen in the small status window in the bottom of
the page.

After this process is completed, remove the microcontroller from the programmer kit and
place it in your system board. Now the system board behaves according to the program
written in the microcontroller.

APPLICATIONS
a) General purpose switching and amplification
b) Induction motor, transformer power factor correction

ADVANTAGES
1.
2.
3.
4.
5.

Rduced demand charges


Increased load carrying capabilities in existing circuits
Improved voltage
Reduced power system loses
Reduction in system losses, and the losses in the cables, lines, and feeder circuits and

therefore lower cable sizes could be opted for.


6. Improved system voltages, thus enable maintaining rated voltage to motors, pumps and
other equipment. The voltage drop in supply conductors is a resistive loss, and wastes
power heating the conductors. Improving the power factor, especially at the motor
terminals, can improve the efficiency by reducing the line current and the line losses.
7. Improved voltage regulation.
8. Increased system capacity, by release of KVA capacity of transformers and cables for the
same KW, thus permitting additional loading without immediate expansion.
9. Efficiency increases due to Reduction of power consumption.
10. Due to reduced power consumption their will be Less greenhouse gases
11. Reduction of electricity bills
12. Extra KVA available from the same existing supply
13. Reduction of IR losses in transformers and distribution equipment

CONCLUSION

Designing a good microcontroller based power factor corection device to help improve power
factor, reduce high current drawn form the system and also reduce harmonic in the system.
Improving the efficiency of the system and reducing high electricity tariffs. It is applicable on a
commercial sinlge phase system.
Expected Outcome Of The Project And Possible Usage The expected out come of this project is
to measuring the power factor value and to improve power factor using capacitor bank and
reduce current draw by the load using microcontroller and proper algorithm to turn on capacitor
automatically, determine and trigger sufficient switching of capacitor in order to compensate
excessive reactive components, thus bringing power factor near to unity and remove harmonics
in the system there by improving the efficiency of the system and reducing the electricity bill.

This paper deals with advance method of power factor correction by using microcontroller. As
Switching of capacitors are done automatically hence we get more accurate result, Power factor
correction techniques makes system stable and due to improvement in power factor its efficiency
also increases. Power factor correction scheme can be applied to industries, power systems as
well as in house hold purpose. The use of microcontroller reduces the costs. By using
microcontroller multiple parameters can be controlled and the use of extra hard wares such as
timer, RAM, ROM and input output ports reduces. Before APFC Circuit insertion

FUTURE SCOPE
The automotive power factor correction using capacitive load banks is very efficient as it
reduces the cost by decreasing the power drawn from the supply. As it operates automatically,
manpower are not required and this Automated Power factor Correction using capacitive load
banks can be used for the industries purpose in the future. In future PWM techniques can be
employed in this scheme. Along with power factor correction also speed control can be done in
future. In future, Work can be done for harmonics reduction.

REFERENCES

[1] en.wikipedia.org/wiki/Power_factor_correcti on
[2] Jones, L. D.; Blackwell, D. (1983) Energy Saver Power Factor Controller for Synchronous
Motors, IEEE Transactions on Power Apparatus and Systems, Volume: 5, Issue: 5, Pages: 13911394.
[3] Keith Harker (1998). Power System Commissioning and Maintenance practice. London:
Institution of Electrical Engineers.
[4] Stephen, J. C. (1999). Electric Machinery and Power System Fundamentals. 3rd.ed. United
State of America: McGraw-Hill Companies, Inc
[5] Oscar Garca, Member, IEEE, Jos A. Cobos, Member, IEEE, Roberto Prieto, Member,
IEEE, Pedro Alou, and Javier Uceda, Senior Member, IEEE Single Phase Power Factor
Correction: A Survey. IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 18, NO.
3, MAY 2003.
[6] Anagha Soman, Assistant Professor, Pranjali Sonje, Pursuing M-Tech, Bharati Vidyapeeth
University college of Engineering, Pune Power Factor Correction Using PIC Microcontroller,
International Journal of Engineering and Innovative Technology (IJEIT) Volume 3, Issue 4,
October 2013.
[7] Jaehong Hahn, Student Member, IEEE, Prasad N. Enjeti, Fellow, IEEE, and Ira J.Pitel,
Fellow, IEEE A New Three-Phase Power-Factor Correction (PFC) Scheme Using Two SinglePhase PFC Modules IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 38,
NO. 1, JANUARY/FEBRUARY 2002 123.

You might also like