Abstract

The study of the thermal conductivity in different cases is presented and their
obtainment by measurement apparatus. This is a regression analysis estimation
of thermal conductivity using a guarded hot plate (GHP) apparatus of different
materials. Other guarded hot plate apparatus (GHPA) is used for insulating
materials applied to circulating heat sources. A new guarded parallel plate (GPP)
measures the thermal conductivity of fluids and solids.
The thermal conductivity of the materials is calculated from the temperature
difference occurring between the plates studied, it depends of their dimensions
and heat generated by a device. The aim of this study is to know theoretically
and using different mathematical, probabilistic, numerical or analytical methods,
the temperature distribution between a plate and another of different material in
real working conditions. It needs to determinate the reliability of the proposed
processes for obtaining the thermal conductivity of the materials, the purpose of
these measuring devices is, to apply in all possible and actual working conditions
that they are in the presence of highly porous materials in which the conductivity
is affected by the convection. These devices have a deviation of 3 to 6%
according to the temperature difference which it works. Using a mathematical
model as the Green and Bessel function to solve the differential equation of the
conduction with generation based on Fourier's Law, it has a high accuracy. Using
regression analysis estimation of thermal conductivity, the heat flow should be
symmetric with a correlation between the temperatures of the bottom and top of
the plates to obtain a k bottom=ktop. The correlation of temperature gradient of the
top and bottom of the plate is given by comparing the material or structure for
thermal conductivity results giving a well convergence of the regression
coefficient.
Discrepancy in the thermal conductivity of the top and bottom side can be
attributed to the presence of convection in the specimen. This method can be
used to observe the influence of direction heating and also the importance of
convective heat flow through the porous insulation materials. The design of the
measuring device influence in the reduction of heat loss that in the case of fluids
such as water is lower than in air or toluene.
References
Sanjaya, C. S., Wee, T. H., & Tamilselvan, T. (2011). Regression analysis estimation of thermal
conductivity using guarded-hot-plate apparatus. Applied Thermal Engineering, 31(10), 1566-1575.

Xamn, J., Lira, L., & Arce, J. (2009). Analysis of the temperature distribution in a guarded hot plate
apparatus for measuring thermal conductivity. Applied Thermal Engineering, 29(4), 617-623.
Rausch, M. H., Krzeminski, K., Leipertz, A., & Frba, A. P. (2013). A new guarded parallel-plate
instrument for the measurement of the thermal conductivity of fluids and solids. International Journal
of Heat and Mass Transfer, 58(1), 610-618.

Abstract
Se presenta el estudio de la conductividad trmica en diferentes casos y su
obtencin mediante aparatos de medicin. Se trata de una estimacin de
anlisis de regresin de la conductividad trmica usando una guarded hot plate
(GHP) apparatus de diferentes materiales. Otro aparato de guarded hot plate
(GHPA) se utiliza para materiales aislantes aplicados a fuentes de calor
circulante. Un nuevo guarded parallel plate (GPP) mide la conductividad trmica
de fluidos y slidos.
La conductividad trmica de las muestras se calcula a partir de la diferencia de
temperatura que se presenta entre las placas o muestras, tomando en cuenta
sus dimensiones y el calor generado por algn dispositivo. El objetivo de este
trabajo es conocer tericamente y con la utilizacin de diferentes mtodos
matemticos, probabilsticos, numricos o analticos, la distribucin de
temperatura entre una placa y otra en diferentes condiciones de trabajo. Se
necesita determinar la confiabilidad de los procesos planteados para la
obtencin de la conductividad trmica de los materiales para que estos aparatos
de medicin sean aplicados en todas las condiciones posibles y reales de trabajo
como son en presencia de materiales altamente porosos en el cual la
conductividad se ve afectada por la conveccin. Estos aparatos tienen una
desviacin de entre 3 a 6% de acuerdo a la diferencia de temperaturas con las
que se trabaje. Al utilizar un modelo matemtico como la funcin de Green y
Bessel para la resolucin de la ecuacin diferencial de la conduccin con
generacin partiendo de la Ley de Fourier, se tiene una gran exactitud. Al utilizar
regression analysis estimation of termal conductivity, se supone un flujo de calor
asimtrico pero con una correlacin entre las temperaturas de las placas o
muestras. La correlacin de gradiente de temperatura de la parte superior e inferior de la placa
estar dada por la comparacin entre los materiales o su estructura para los resultados de
conductividad trmica.
la discrepancia en el coeficiente de conductividad trmica de las muestras superior e inferior se
puede atribuir a la presencia de conveccin en las muestras. Este mtodo se puede utilizar

para observar la influencia de la direccin de calentamiento y tambin la


importancia del flujo de calor por conveccin a travs del aislamiento en
materiales porosos. El diseo del aparato de medicin influye en la reduccin de
fugas de calor que en el caso de fluidos como el agua son mucho menores que
en el aire o el tolueno.