MonitoringManagement
FeatureParameterDescription
CopyrightHuaweiTechnologiesCo.,Ltd.2012.Allrightsreserved.
NopartofthisdocumentmaybereproducedortransmittedinanyformorbyanymeanswithoutpriorwrittenconsentofHuawei
TechnologiesCo.,Ltd.
TrademarksandPermissions
andotherHuaweitrademarksarethepropertyofHuaweiTechnologiesCo.,Ltd.Allothertrademarksandtradenames
mentionedinthisdocumentarethepropertyoftheirrespectiveholders.
Notice
Thepurchasedproducts,servicesandfeaturesarestipulatedbythecommercialcontractmadebetweenHuaweiandthecustomer.All
orpartialproducts,servicesandfeaturesdescribedinthisdocumentmaynotbewithinthepurchasedscopeortheusagescope.
Unlessotherwiseagreedbythecontract,allstatements,information,andrecommendationsinthisdocumentareprovided"ASIS"
withoutwarranties,guaranteesorrepresentationsofanykind,eitherexpressorimplied.
Theinformationinthisdocumentissubjecttochangewithoutnotice.Everyefforthasbeenmadeinthepreparationofthisdocumentto
ensureaccuracyofthecontents,butallstatements,information,andrecommendationsinthisdocumentdonotconstituteawarrantyof
anykind,expressorimplied.
Contents
1Introduction
1.1Scope
1.2IntendedAudience
1.3ChangeHistory
2OverviewofMonitoringManagement
2.1MonitoringManagers
2.1.1BBUMonitoringPorts
2.1.2CCUMonitoringPorts
2.1.3RRUMonitoringPorts
2.2MonitoringPrinciples
2.2.1Singlemode/DualmodeBaseStation
2.2.2TriplemodeBaseStation
2.3CustomizedAlarms
3EngineeringGuidelines
4EngineeringGuidelines(UMTSorLTE)
4.1WhentoUseMonitoringManagement
4.2InformationtoBeCollected
4.3NetworkPlanning
4.4FeatureDeployment
4.4.1DeploymentProcedure
4.4.2DeploymentRequirements
4.4.3DataPreparation
4.4.4Precautions
4.4.5HardwareInstallation
4.4.6FeatureActivation/InitialConfiguration
4.4.7Commissioning
4.4.8ActivationVerification
4.4.9Reconfiguration
4.4.10Deactivation
4.5Optimization
4.6Troubleshooting
5EngineeringGuidelines(GSM)
5.1WhentoUseMonitoringManagement
5.2InformationtoBeCollected
5.3NetworkPlanning
5.4FeatureDeployment
5.4.1DeploymentProcedure
5.4.2DeploymentRequirements
5.4.3DataPreparation
5.4.4Precautions
5.4.5HardwareInstallation
5.4.6FeatureActivation/InitialConfiguration
5.4.7Commissioning
5.4.8ActivationVerification
5.4.9Reconfiguration
5.4.10Deactivation
5.5Optimization
5.6Troubleshooting
6EngineeringGuidelines(DualModes)
6.1PrecautionsforOneSidedConfiguration
6.2PrecautionsforModebyModeConfiguration
7ReferenceDocuments
1Introduction
1.1Scope
Thisdocumentdescribestheprinciplesandengineeringguidelinesforthe3900seriesbasestationmonitoringmanagementfeature.
The3900seriesbasestationmonitoringmanagementfeatureinvolvestwobasicLTEfeatures,LBFD004012EnvironmentMonitoring
andTDLBFD004012EnvironmentMonitoring.InGBSS,RAN,andSRAN,the3900seriesbasestationmonitoringmanagementisa
basicfeatureandinvolvesnofeatureID.
Thisdocumentisapplicabletothefollowing3900seriesbasestations:
BTS3900(Ver.B),BTS3900(Ver.C),andBTS3900(Ver.D)
BTS3900L(Ver.B),BTS3900L(Ver.C),andBTS3900L(Ver.D)
BTS3900A(Ver.B),BTS3900A(Ver.C),andBTS3900A(Ver.D)
BTS3900AL(Ver.A)
DBS3900
BTS3900C,BTS3900C(Ver.B),andBTS3900C(Ver.C)
Anymanagedobjects(MOs),parameters,alarms,orcountersdescribedinthisdocumentcorrespondtothesoftwarereleasedelivered
withthisdocument.Intheeventofupdates,theupdateswillbedescribedintheproductdocumentationdeliveredwiththelatest
softwarerelease.
1.2IntendedAudience
Thisdocumentisintendedfor:
Personnelwhoneedtounderstandmonitoringmanagement
Fieldengineers
1.3ChangeHistory
Thissectionprovidesinformationaboutthechangesindifferentdocumentversions.
Therearetwotypesofchanges,whicharedefinedasfollows:
Featurechange:referstoachangeinthemonitoringmanagementfeatureofaspecificproductversion.
Editorialchange:referstoachangeinwordingortheadditionofinformationthatwasnotdescribedintheearlierversion.
DocumentIssues
Thedocumentissuesareasfollows:
03(20120915)
02(20120723)
01(20120425)
DraftB(20120310)
DraftA(20120110)
03(20120915)
Thisisthethirdcommercialrelease.
Comparedwithissue02(20120723),thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type
ChangeDescription
ParameterChange
Feature
change
Addedthefollowinginformation:
MonitoringprinciplesoftheBTS3900(Ver.D)
in"BTS3900"insection2.2.1"Single
mode/DualmodeBaseStation."
None
MonitoringprinciplesoftheBTS3900L
(Ver.D)in"BTS3900L"insection2.2.1
"Singlemode/DualmodeBaseStation."
MonitoringprinciplesoftheBTS3900A
(Ver.D)in"BTS3900A"insection2.2.1
"Singlemode/DualmodeBaseStation."
MonitoringprinciplesoftheDBS3900housed
intheAPM30H(Ver.D)orTMC11H(Ver.D)
in"DBS3900"insection2.2.1"Single
mode/DualmodeBaseStation."
Editorial
change
None
None
02(20120723)
Thisisthesecondofficialrelease.
Comparedwithissue01(20120425),thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type
ChangeDescription
ParameterChange
Feature
change
Addedthelownoisemodeforthefan.
AddedtheTCMODEparameter
fortheFMUinGSM,UMTS,and
LTEmodes.
Editorial
change
None
None
01(20120425)
Thisisthefirstofficialrelease.
ComparedwithdraftB(20120310),thisissuedoesnotincorporateanychange.
DraftB(20120310)
Thisisadraft.
ComparedwithdraftA(20120110),thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type
ChangeDescription
ParameterChange
Feature
change
TheparametervalueGS_DISABLE(Door
SensorDisabled)ofSBAFinCCUisdeleted.
None
Editorial
change
Addedchapter3"EngineeringGuidelines."
None
Optimizedtheprecautionsofchapter6
"EngineeringGuidelines(DualModes)."
None
DraftA(20120110)
Thisisadraft.
ThisdocumentisthefirstreleaseforSRAN7.0,GBSS14.0,andRAN14.0.
ForeRAN3.0,thisdocumentismodifiedbasedonissue03(20111224)ofeRAN2.2.Comparedwithissue03(20111224)of
eRAN2.2,thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type
ChangeDescription
ParameterChange
Feature
change
AddedthefollowingBTS3900ALrelated
information:
MonitoringprinciplesoftheBTS3900ALin
section2.2.1"Singlemode/DualmodeBase
Station."
AddedtheCCUMO.
AddedthefollowingCCUrelated
parameters:
CCUinformationinsection2.1.2"CCU
MonitoringPorts."
Editorial
change
DCF
CCN
CS
Addedthemonitoringprinciplesofthe
DBS3900housedintheTP48600Acabinetin
section2.2.1"Singlemode/DualmodeBase
Station."
None
Addedthemonitoringprinciplesand
engineeringguidelinesfortheNodeB,BTS,
andMBTS.
AddedGSMandUMTS
configurationparameters.
Addedsection2.2"MonitoringPrinciples."
None
Addedthereferenceforconfiguringthe
monitoringfunctioninsection4.4.3"Data
Preparation."
None
2OverviewofMonitoringManagement
Themonitoringsystemisanimportantcomponentofabasestation.Thesystemmonitorsthepowersupply,fans,andenvironmentin
thecabinet.Whenafaultisdetected,thesystemreportsanalarm.Inaddition,themonitoringsystemcollectsalarmsignalsfrom
outsidethecabinettomonitortheenvironmentandspecifieddevices,suchasdieselgeneratorsandequipmentroomdoorstatus
controldevices.
2.1MonitoringManagers
Themonitoringmanagersincludethebasebandunit(BBU),cabinetcontrolunit(CCU),andradioremoteunit(RRU).Themonitored
devicesinthecabinetcommunicatewiththemonitoringmanagersthroughanRS485bus.
TheBBUisthemonitoringmanagementcenterformostbasestations.Bothinternalandexternalalarmsaredirectlyreportedtothe
BBUandthenforwardedtothealarmconsole.
Whenabasestationhasmanydevicestobemonitoredinthecabinets,theBBUmonitoringportscannotmeetthemonitoring
requirements.Inthissituation,theCCUofeachcabinetmonitorsdeviceshousedinthecabinet.TheCCUsarecascadedandoneCCU
reportsalarmstotheBBU.Currently,onlytheBTS3900ALcabinet,TP48600AH17B1(TP48600Aforshort)cabinetforDBS3900,and
IBBS700D/IBBS700TcabinetusetheCCUstoimplementmonitoringmanagement.
ForsomeDBS3900s,alarmsaremanagedbytheRRUbecausetheRRUisinstalledfarawayfromtheBBU.TheRRUreportsalarms
totheBBUthroughacommonpublicradiointerface(CPRI)fiberopticcableandtheBBUthenforwardsthealarmstothealarm
console.Thisscenarioiscalledremotemonitoring.
2.1.1BBUMonitoringPorts
InaBBU,theuniversalpowerandenvironmentinterfaceunit(UPEU)anduniversalenvironmentinterfaceunit(UEIU)boardsprovide
monitoringports.EachboardprovidestwoBooleaninputportsandtwoRS485inputports.EachBooleaninputportsupportsfour
Booleaninputs.
WhenaBBUisconfiguredwithoneUPEU,theBBUprovideseightBooleaninputsandtwoRS485inputs.
WhenaBBUisconfiguredwithtwoUPEUsorwithoneUPEUandoneUEIU,theBBUprovides16BooleaninputsandfourRS485
inputs.ThetwoMON0portsondifferentUPEUsorontheUPEUandUEIUareinterconnectedthroughRS485bus0,andthetwo
MON1portsareinterconnectedthroughRS485bus1.
Figure21showsthemonitoringportsontheUPEUandUEIU.
Figure21MonitoringportsontheUPEUandUEIU
Table21describesthemonitoringportsontheUPEUandUEIU.
Table21MonitoringportsontheUPEUandUEIU
Board
Label
Connector
Description
UPEU
EXTALM0
RJ45
ForBooleaninputs0to3
EXTALM1
RJ45
ForBooleaninputs4to7
MON0
RJ45
RS485inputport0
MON1
RJ45
RS485inputport1
EXTALM0
RJ45
ForBooleaninputs0to3
EXTALM1
RJ45
ForBooleaninputs4to7
MON0
RJ45
RS485inputport0
MON1
RJ45
RS485inputport1
UEIU
2.1.2CCUMonitoringPorts
TheCCUmonitorstheenvironmentanddevicesinthecabinet.Figure22showsthemonitoringportsontheCCU.
Figure22CCUmonitoringports
Table22describesthemonitoringportsontheCCU.FordetailsaboutthefunctionsoftheotherportsontheCCU,seesection"CCU"
inBTS3900AL(Ver.A)HardwareDescription.
Table22CCUmonitoringports
Label
Connector
Description
FE_L,FE_R
RJ45
ForCCUcascading
D_COM0toD_COM7
RJ45
DownlinkRS485ports0to7for
communicatingwithboardsinthecabinet
U_COM0toU_COM2
RJ45
UplinkRS485ports0to2forcommunicating
withupperlevelboards
TEM
4pinwireterminalblock
Reservedforthetemperaturesensor
SMOKE
2pinwireterminalblock
Forthesmokesensorthatisoptionally
configured
GATE
2pinbarewireterminal
block
Forthedoorstatussensorthatisconfigured
bydefault
IN0
2pinbarewireterminal
block
ReservedfortwoBooleaninputs
IN1
2pinbarewireterminal
block
FortheACsurgeprotectorthatisconfigured
bydefault
LAMP
2pinbarewireterminal
block
Forthecabinetlampthatisconfiguredby
default
2.1.3RRUMonitoringPorts
RRUmonitoringportsvarywithRRUmodels.SomeRRUsprovideonemonitoringportwhichsupportstwoorfourBooleaninputsand
oneRS485input.SomeRRUsdonotprovideanymonitoringport.
Fordetails,seesection"RRUPorts"intheRRUspecifichardwaredescription.
2.2MonitoringPrinciples
2.2.1Singlemode/DualmodeBaseStation
Themonitoringboardsofabasestationreportmonitoringinformation.Forexample,thefanmonitoringunit(FMU)reportsfan
monitoringinformation,thepowermonitoringunit(PMU)reportspowersupplymonitoringinformation,andtheenvironmentmonitoring
unit(EMU)orenvironmentmonitoringunittypeA(EMUA)reportsenvironmentmonitoringalarmsandcustomizedalarms.Allthe
monitoringsignalsaretransmittedtotheBBU,CCU,orRRUmonitoringportsthroughanRS485bus.Thissectiondescribesthe
connectionsbetweenthemonitoringboardsandtheBBU,CCU,andRRU.
Fordetailsabouthowtoconnectthemonitoringsignalcablesoftheboardstorelevantports,seesections"MonitoringPrinciplesoftheCabinet"and
"MonitoringSignalCableConnections"inthebasestationspecifichardwaredescription.
BTS3900
Figure23showsthemonitoringprinciplesoftheBTS3900cabinet(AC).ThemonitoringprinciplesoftheBTS3900(Ver.B),BTS3900
(Ver.C),andBTS3900(Ver.D)cabinetsarethesame.TheFMU,PMU,andGSMantennaandTMAcontrolmodule(GATM)
communicatewiththeBBU'sMONportsthroughanRS485serialbus.TheGATMisaBTSspecificboardandisnotusedwiththe
NodeBoreNodeB.
Themonitoredboardsarecascadedinsequence.Ifalowerlevelboardisnotconfigured,themonitoringsignalcableisdirectly
connectedtoanupperlevelboard.Forexample,iftheGATMisnotconfigured,theFMUandPMUaredirectlyconnectedtotheBBU's
MONports.
Figure23MonitoringprinciplesoftheBTS3900(AC)
Cabinet0isthefirstcabinetofthistypeconfiguredatasite.Thesameruleappliestonumberingtheothercabinetsofthistype.
ThemonitoringprinciplesoftheBTS3900cabinet(48VDC)andthoseoftheBTS3900cabinet(+24VDC)aresimilar.Inboth
cabinets,thePMUisnotconfiguredandcanbeignoredinFigure23.Inaddition,theDC/DCpowersystemoftheBTS3900cabinet
(+24VDC)needstobeconnectedtotheBBU'sEXT_ALMporttoreportBooleansignals.
BTS3900L
Figure24showsthemonitoringprinciplesoftheBTS3900Lcabinet(48VDC).ThemonitoringprinciplesoftheBTS3900L(Ver.B),
BTS3900L(Ver.C),andBTS3900L(Ver.D)cabinetsarethesame.TheFMUandGATMcommunicatewiththeBBU'sMONports
throughanRS485serialbus.TheGATMisaBTSspecificboardandisnotusedwiththeNodeBoreNodeB.
Themonitoredboardsarecascadedinsequence.Ifalowerlevelboardisnotconfigured,themonitoringsignalcableisdirectly
connectedtoanupperlevelboard.Forexample,iftheGATMisnotconfigured,theFMUisdirectlyconnectedtotheBBU'sMONport.
InFigure24,FMU0referstotheFMUinthelowerlevelsubrackandFMU1referstotheFMUintheupperlevelsubrackinthe
BTS3900Lcabinet.CascadethemfollowingthesequenceshowninFigure24.
Figure24MonitoringprinciplesoftheBTS3900L
BTS3900A
Figure25andFigure26showthemonitoringprinciplesoftheBTS3900Acabinet(AC)andBTS3900Acabinet(DC),respectively.The
centralmonitoringunittypeA(CMUA)/centralmonitoringunittypeE(CMUE)/centralmonitoringunittypeEA(CMUEA),PMU,GATM,
andEMUcommunicatewiththeBBU'sMONportsthroughanRS485serialbus.TheGATMisaBTSspecificboardandisnotused
withtheNodeBoreNodeB.
Themonitoredboardsarecascadedinsequence.Ifanupperlevelboardisnotconfigured,themonitoringsignalcableisdirectly
connectedtoalowerlevelboard.Forexample,iftheTMCcabinetisnotconfigured,ignoretheconnectionsrelatedtoTMCcabinet
connectionsshowninFigure25andFigure26.TheCMUEincabinetRFC0isdirectlyconnectedtotheCMUEincabinetRFC1.
ThemonitoringprinciplesoftheBTS3900A(Ver.B)cabinetarethesameasthoseoftheBTS3900A(Ver.C)cabinet,exceptthatthe
CMUEisreplacedwiththeCMUA.
ThemonitoringprinciplesoftheBTS3900A(Ver.D)cabinetarethesameasthoseoftheBTS3900A(Ver.C)cabinet,exceptthatno
Hertpowermonitoringinterfaceunit(HPMI)isconfiguredandtheCMUEisreplacedwiththeCMUEA.TheHPMIdoesnotmonitor
signalsbuttransferssignalsforthePMU.Figure25andFigure26showthemonitoringprinciplesonlyfortheBTS3900A(Ver.C)
cabinet.
Twobatterybackupcabinets(BBCs)arecascadedinsequenceandcannotbeconnectedtothesamePMU.Forexample,ifBBC0
connectstothePMU'sCOM_485port,BBC1connectstotheCMUE'sCOM_OUTportinBBC0andcannotbeconnectedtotheother
RS485portsonthePMU.
Figure25MonitoringprinciplesoftheBTS3900A(AC)
TheBBCcabinetreferstoIBBS200DandIBBS200T(IBBSisshortforintegratedbackupbatterysystem).
Figure26MonitoringprinciplesoftheBTS3900A(48VDC)
DBS3900
TheDBS3900hasmultipleapplicationscenarios.TheDBS3900monitoringprinciplesvarywithhardwareconfigurations,asdescribed
inTable23.
Table23IndextableofDBS3900monitoringprinciples
InstallationScenario
(InputPower)
InstallationScenario(Cabinet
Configuration)
Description
110VAC/220VAC
APM30H(Ver.C),TMC11H(Ver.C),and
IBBS200D(Ver.C)/IBBS200T(Ver.C)
Themonitoringprinciplesarethe
sameasthoseoftheBTS3900A
cabinet(AC).SeeFigure25.
APM30H(Ver.B),TMC11H(Ver.B),and
IBBS200D(Ver.B)/IBBS200T(Ver.B)
APM30H(Ver.D),TMC11H(Ver.D),and
IBBS200D(Ver.D)/IBBS200T(Ver.D)
TheDBS3900isnotconfiguredwith
theGATMortheRFCcabinet,sothe
cableconnectionstotheGATMorto
theRFCcabinetcanbeignored.The
BBUintheAPM30Hcabinetis
directlyconnectedtotheCMUEin
theTMC11Hcabinet.
110VAC/220VAC
APM30H(Ver.B)/APM30H(Ver.C)/
APM30H(Ver.D),and
IBBS200D/IBBS200T,inRRUremote
monitoringmode
SeeFigure27.
110VAC/220VAC
TP48600A
SeeFigure28.
48VDC
TMC11H(Ver.B)
SeeinFigure29.
TMC11H(Ver.C)
APM30H(Ver.D)
+24VDC
APM30H(Ver.B)
See
inFigure29.
110VAC/220VAC
Outdoorminibox(OMB)
SeeinFigure29.
48VDC
OMB
SeeinFigure29.The
monitoringprinciplesaresimilar
tothoseoftheOMB(AC)except
thatthePMUisnotusedforthe
OMB(DC).
110VAC/220VAC
OMB(Ver.C)
SeeinFigure29.
48VDC
OMB(Ver.C)
SeeinFigure29.The
monitoringprinciplesaresimilar
tothoseoftheOMB(AC)except
thatthePMUisnotusedforthe
OMB(DC).
110VAC/220VAC
Indoorcentralizedrack(ICR):BBUand
PMUareinstalledintheupperandlower
racksrespectivelyintheindoorminibox
(IMB03)
See
inFigure29.
+24VDC
ICR:BBUisinstalledintheIMB03
See
inFigure29.
110VAC/220VAC
IMB03
See
inFigure29.
48VDC
IMB03
Monitoringisnotrequired.
FortheAPM/TMCseriescabinetsusedintheDBS3900inRRUremotemonitoringmode,themonitoringprinciplesoftheVer.B
cabinetsarethesameasthoseoftheVer.Ccabinets,exceptthattheCMUEisreplacedwiththeCMUA.Inaddition,themonitoring
principlesoftheVer.DcabinetsarethesameasthoseoftheVer.Ccabinets,exceptthattheCMUEisreplacedwiththeCMUEA.Figure
27showsthemonitoringprinciplesoftheVer.Ccabinets.
ThemonitoringprinciplesoftheOMB(Ver.C)cabinetarethesameasthoseoftheOMBcabinet,exceptthattheHEUAisreplacedwith
theHEUB.Figure29showsthemonitoringprinciplesoftheOMBcabinet.
Figure27Remotemonitoringprinciples
Figure28MonitoringprinciplesoftheDBS3900housedinTP48600A
Figure29MonitoringprinciplesoftheDBS3900housedinothercabinets
BTS3900AL
TheBTS3900ALusesCCUstomonitorboardsinitscabinets,asshowninFigure210.TheCMUF,FAU,andPMUcommunicatewith
theCCUs'downlinkRS485portsthroughanRS485serialbus.OneCCUthenreportsalarmstotheBBUthroughtheCCU'suplink
RS485port.TheGATMisaBTSspecificboardandisnotusedwiththeNodeBoreNodeB.
IftheTMCandIBBS700D/IBBS700Tcabinetsarenotconfigured,ignoretheboardsinthesecabinets.
Figure210MonitoringprinciplesoftheBTS3900ALinsinglemodeordualmode
BTS3900C
ThemonitoringprinciplesoftheBTS3900CarethesameasthoseoftheDBS3900housedintheOMB.Themonitoringprinciplesofthe
BTS3900C(Ver.C)arethesameasthoseoftheDBS3900housedintheOMB(Ver.C).Fordetails,seeTable23.
2.2.2TriplemodeBaseStation
TwoBBUsarerequiredforthebasestationevolutionfromsingleordualmodetotriplemodeorwhenatriplemodebasestationis
deployed.
AllthemonitoreddevicesoftheBTS3900,BTS3900L,BTS3900A,andDBS3900(nothousedinTP48600A)areconnectedonlyto
BBU0(hubBBU).TheextensionBBUdoesnotprovidemonitoringmanagement.
Figure211showsthemonitoringprinciplesoftheBTS3900ALwheretwoBBUsareconfigured.BBU0andBBU1areconnectedto
theCCU'suplinkRS485portsU_COM0andU_COM1,respectively.ThemonitoringprinciplesoftheDBS3900housedinTP48600A
aresimilar.
Figure211MonitoringprinciplesoftheBTS3900ALintriplemode
2.3CustomizedAlarms
Youcancustomizealarmstomonitorexternaldevices.
ToimplementBooleansignalinput,connectthemonitoreddevicestotheBBU,RRU,EMU,orEMUAthathasBooleanalarmsignal
inputports.
Toimplementanalogsignalinput,connectthemonitoreddevicestotheEMUorEMUAthathasanalogalarmsignalinputports.
ToimplementBooleansignaloutput,connectthemonitoreddevicestotheEMUorEMUAthathasBooleansignaloutputports.
Ambientalarmsarecommoncustomizedalarms.Theyaregeneratedaftersensorsinstalledoutdoorsorintheequipmentroomreceive
alarmsignals.Somebasestationshavesensorsthatarepreinstalledbeforedelivery,asshowninTable24.
Table24Sensorspreinstalledonbasestationsbeforedelivery
BaseStationType
Cabinet
PreinstalledSensor
BTS3900/BTS3900L
BTS3900/BTS3900L
None
BTS3900A/DBS3900 (1)
APM30H(Ver.B)/APM30H
(Ver.C)
Doorstatussensor,whichis
connectedtotheHPMI'sGATE
port.
APM30H(Ver.D)
Doorstatussensor,whichis
connectedtothePMU'sGATE
port.
RFC
Doorstatussensor,whichis
(2)
connectedtotheCMUA's(3),
CMUE's,orCMUEA'sGATE
port.
Temperaturesensor,whichis
connectedtotheCMUA's,
CMUE's,orCMUEA'sTEMport.
TMC11H
Doorstatussensor,whichis
connectedtotheCMUA's(4),
CMUE's,orCMUEA'sGATEport.
IBBS200D/IBBS200T
Doorstatussensor,whichis
connectedtotheCMUA's,
CMUE's,orCMUEA'sGATE
port.
Temperaturesensorforthe
battery,whichisconnectedto
theCMUA's,CMUE's,or
CMUEA'sTEM_BATport.
BTS3900AL(5)
BTS3900AL(AC)/BTS3900AL(DC)
Doorstatussensor,whichis
connectedtotheCCU'sGATE
port.
Returnairtemperaturesensorfor
HEXinnercirculation,whichis
connectedtotheCMUF'sTEM0
port.
Intakeairtemperaturesensorfor
theRFcompartment,whichis
connectedtotheFAU'sTEM0
port.
Supplyairtemperaturesensorfor
HEXinnercirculation,whichis
connectedtotheCMUF's
TEMP1port.
BTS3900C
TMC11H
Doorstatussensor,whichis
connectedtotheCMUA's,
CMUE's,orCMUEA'sGATEport.
BTS3900C
None
(1)TheDBS3900housedintheOMBorIMBdoesnothavepreinstalledsensors.
(2)TheDBS3900mayalsobeconfiguredwiththeTP48600Acabinet.Fordetailsaboutthesensorconfigurationinthiscabinet,seeTP48600AH17B1User
Manual.
(3)IntheBTS3900A(Ver.B),thesensorsareconnectedtotheCMUA.IntheBTS3900A(Ver.C),thesensorsareconnectedtotheCMUE.IntheBTS3900A
(Ver.D),thesensorsareconnectedtotheCMUEA.
(4)IntheTMC11H(Ver.B),thesensorsareconnectedtotheCMUA.IntheTMC11H(Ver.C),thesensorsareconnectedtotheCMUE.IntheTMC11H(Ver.D),
thesensorsareconnectedtotheCMUEA.
(5)TheBTS3900ALmayalsobeconfiguredwiththeTP48600AandIBBS700D/IBBS700Tcabinets.Fordetailsaboutthesensorconfigurationinthese
cabinets,seeTP48600AH17B1UserManualandIBBS700D&IBBS700TUserManual.
3EngineeringGuidelines
Inamultimodebasestation,deploytheMonitoringManagementfeatureeitherinsingleordualmodes.
Forthemethodofdeployingthisfeatureinsinglemode,seechapter4"EngineeringGuidelines(UMTSorLTE)"andchapter5
"EngineeringGuidelines(GSM)."
Forthemethodofdeployingthisfeatureindualmode,seechapter6"EngineeringGuidelines(DualModes)."
4EngineeringGuidelines(UMTSorLTE)
4.1WhentoUseMonitoringManagement
ItisrecommendedthatthemonitoringmanagementfeaturebeenabledwhenyouintendtomonitorpowerandfanunitsinaNodeBor
eNodeB.IfauxiliarydevicescapableofmonitoringfunctionsareconfiguredforaNodeBoreNodeB,itisrecommendedthatthe
customizedalarmfunctionbeenabled.
4.2InformationtoBeCollected
Softwareconfigurationvariesaccordingtohardwareconfigurationandcableconnectionsbetweenmonitoringboards.Beforeyou
configuresoftware,collectinformationaboutthefollowingdevicesbasedonthehardwareconfigurationorhardwareconfigurationplan:
Plannedorinstalledboardsrelatedtomonitoring
Table41liststheboardsthatneedtobeconfiguredfordifferenttypesofNodeBsandeNodeBsindifferentscenarios.
Devicesthatmanageboards
BoardmanagersincludeBBU,CCU,andRRU.Collecttheirrespectiveinformationaccordingtothehardwareconnectionsonsite.
ThelogicalnamesinTable41arethenamesofdevicesdisplayedontheconfigurationtoolinterface.
Table41BoardsrequiredfordifferenttypesofNodeBsandeNodeBsindifferentscenarios
NodeBandeNodeB
Type
UsageScenario
BTS3900(Ver.B)
BTS3900(Ver.C)
BTS3900(Ver.D)
BTS3900L(Ver.B)
BTS3900L(Ver.C)
Board
Logical
Name
48VDCpowerinput
FMU
FMU
+24VDCpowerinput
FMU
FMU
110VAC/220VACpowerinput
FMU
FMU
PMU
PMU
PMU
PMU
CMUA
TCU
CMUA
FMU
BTS3900L(Ver.D)
BTS3900A(Ver.B)
RequiredBoard
APM30H(Ver.B)cabinet
RFC(Ver.B)cabinet
BTS3900A(Ver.C)
BTS3900A(Ver.D)
DBS3900
TMC11H(Ver.B)cabinet
CMUA
TCU
IBBS200D(Ver.B)/IBBS200T(Ver.B)
cabinet
CMUA
TCU
APM30H(Ver.C)cabinet
PMU
PMU
CMUE
TCU
RFC(Ver.C)cabinet
CMUE
FMU
TMC11H(Ver.C)cabinet
CMUE
TCU
IBBS200D(Ver.C)/IBBS200T(Ver.C)
cabinet
CMUE
TCU
APM30H(Ver.D)cabinet
PMU11A
PMU
CMUEA
TCU
RFC(Ver.D)cabinet
CMUEA
FMU
TMC11H(Ver.D)cabinet
CMUEA
TCU
IBBS200D(Ver.D)/IBBS200T(Ver.D)
cabinet
CMUEA
TCU
APM30H(Ver.B)cabinet
PMU
PMU
CMUA
TCU
TMC11H(Ver.B)cabinet
CMUA
TCU
IBBS200D(Ver.B)/IBBS200T(Ver.B)
cabinet
CMUA
TCU
IBBS700DorIBBS700Tcabinet
CCU
CCU
CMUF
TCU
HAU
TCU
PMU
PMU
CMUA
TCU
TMC11H(Ver.C)cabinet
CMUE
TCU
IBBS200D(Ver.C)/IBBS200T(Ver.C)
cabinet
CMUE
TCU
APM30H(Ver.D)cabinet
PMU11A
PMU
CMUEA
TCU
TMC11H(Ver.D)cabinet
CMUEA
TCU
IBBS200D(Ver.D)/IBBS200T(Ver.D)
cabinet
CMUEA
TCU
OMBcabinet
HEUA
TCU
PMU
PMU
HEUB
TCU
PMU11A
PMU
IMBcabinet
PMU
PMU
IMBcabinet(inICRscenario)
PMU
PMU
TP48600Acabinet
CCU
CCU
PMU
PMU
CMUF
TCU
HAU
TCU
CCU
CCU
CMUF
TCU
PMU
PMU
FAU
FMU
HAU
TCU
CCU
CCU
CMUF
TCU
APM30H(Ver.C)cabinet
OMB(Ver.C)cabinet
BTS3900AL(Ver.A)
BTS3900AL(AC)cabinet
BTS3900AL(DC)cabinet
BTS3900C/BTS3900C
(Ver.B)
BTS3900C(Ver.C)
FAU
FMU
HAU
TCU
TMC11H(Ver.C)cabinet
CMUE
TCU
IBBS700DorIBBS700Tcabinet
CCU
CCU
CMUF
TCU
HAU
TCU
DCpowerinput
HEUA
TCU
ACpowerinput
PMU
PMU
HEUA
TCU
DCpowerinput
HEUB
TCU
ACpowerinput
PMU11A
PMU
HEUB
TCU
ThefullnamesoftheboardslistedinTable41areasfollows:
(1)FMU:fanmonitoringunit
(2)PMU:powermonitoringunit
(3)PMU11A:powermonitoringunit
(4)CMUA:centralmonitoringunittypeA
(5)TCU:temperaturecontrolunit
(6)CCU:cabinetcontrolunit
(7)HEUA:heatexchangeunittypeA
(8)HEUB:heatexchangeunittypeB
(9)CMUE:centralmonitoringunittypeE
(10)CMUF:centralmonitoringunittypeF
(11)CMUEA:centralmonitoringunittypeEA
(12)FAU:fanassemblyunit
(13)HAU:heaterassemblyunit
ThemonitoringboardsrequiredbytheTP48600AcabinetdonotneedtobeconfiguredwhenothercabinetsareconfiguredforaNodeBoreNodeB.
4.3NetworkPlanning
RFPlanning
N/A
NetworkTopology
N/A
HardwarePlanning
ConfigurationPlanningforMonitoringDevices
TheEMUorEMUAmayberequiredforconfiguringcustomizedalarmsonNodeBsandeNodeBs.Table42describesthehardware
planningforcustomizedalarmconfiguration.ThelogicalnamesinTable42arethenamesofdevicesdisplayedontheconfiguration
toolinterface.
Table42Hardwareplanningforcustomizedalarmconfiguration
NodeBand
eNodeBType
UsageScenario
BTS3900(Ver.B)
BTS3900(Ver.C)
BTS3900(Ver.D)
RequiredDevice
DeviceName
LogicalName
1to16Booleanalarminputs
NA(1)
NA
17to32Booleanalarminputs
EMU(2)
EMU
BTS3900L(Ver.B)
1to6Booleanalarmoutputs
EMU
EMU
BTS3900L(Ver.C)
BTS3900L(Ver.D)
RRUremotemonitoring
NA(3)
NA
1to4analogalarminputs
EMU
EMU
BTS3900A(Ver.B)
1to16Booleanalarminputs
NA(1)
NA
BTS3900A(Ver.C)
BTS3900A(Ver.D)
17to32Booleanalarminputs
EMUA(2)
EMU
DBS3900
1to4remoteBooleanalarminputs
NA(3)
NA
1to6Booleanalarmoutputs
EMUA
EMU
BTS3900AL(Ver.A)
BTS3900C(4)
1to4analogalarminputs
EMUA
EMU
1to16Booleanalarminputs
NA(1)
NA
BTS3900C(Ver.B)
(4)
BTS3900C(Ver.C)
(4)
(1)Whendefining1to16Booleaninputs,youcaninstalloneUPEUandoneUEIUinaBBU.Itisrecommendedthatyounotconfigurecustomizedalarmsof
theBooleanportsontheFMU,PMU,CMUA,CMUE,CMUF,orCCU.Ifyouwanttousethem,contactHuaweitechnicalsupport.
(2)TheEMUorEMUAsupports32Booleaninputsandfouranaloginputs.Fordetailsaboutthemonitoringportsonthem,seeEMUUserGuideandEMUA
UserGuide.
(3)SomeRRUssupportonlyoneBooleaninputandsomedonotsupportBooleaninputs.Fordetails,seesection"RRUPorts"intheRRUspecifichardware
description.
(4)TheEMUorEMUAcannotbeinstalledonBTS3900C,BTS3900C(Ver.B),orBTS3900C(Ver.C).
RequirementsforBooleanAlarmInputs
ConsiderthefollowingrequirementswhileplanningBooleanalarminputs:
Basestation'sBooleanalarminputsmustbedrycontactalarminputs.
ItisrecommendedthatopticalcouplingisolationorrelayisolationBooleaninputsbeused.Wheneitheroftheinputsisused,open
circuitindicatesalarmreporting,andshortcircuitindicatesnoalarm.
VoltagesignalsarenotusedasBBUBooleaninputs.Ifvoltagesignalalarmsareused,ensurethatalarmdevicesandalarminput
devices(BBU,EMU,orEMUA)areproperlygrounded.WhentheBBUinputalarmsareofthevoltagetype,0Vto0.7Vindicatelow
voltage,and3Vto5Vindicatehighvoltage.WhentheEMUorEMUAinputalarmsareofthevoltagetype,0Vto0.7Vindicatelow
voltage,and5Vto12Vindicatehighvoltage.
4.4FeatureDeployment
4.4.1DeploymentProcedure
Thereisnofixedsequenceforconfiguringthemonitoringmanagementfeature.
4.4.2DeploymentRequirements
None
4.4.3DataPreparation
GenericData
None
ScenariospecificData
Thefollowingscenarioscanbeusedtogether.Iftheyareusedtogether,dataforallthesescenariosmustbeprepared.
Scenario1:ConfiguringthePMU
FortheparametersettingsforthePMU,seePowerManagementFeatureParameterDescription.
Scenario2:ConfiguringtheFMU
Table43describestheparametersettingsfortheFMU.
Table43ParametersettingsfortheFMU
Parameter
Name
Parameter
ID
SettingDescription
Source
Thisparameterspecifiesthenumberofthe
cabinethousingtheFMU.
CabinetNo.
CN
IfthenumberoftheRFChousingtheFMUis1,
setthisparameterto1.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Network
plan
Thisparameterspecifiesthenumberofthe
subrackhousingtheFMU.
SubrackNo.
SRN
SlotNo.
SN
Setthisparameterto11or12.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberoftheslot
housingtheFMU.
Setthisparametertothedefaultvalue0.
Network
plan
Network
plan
Manager
CabinetNo.
Manager
SubrackNo.
MCN
ThemanageroftheFMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothecabinet
numberoftheBBU,CCU,orRRU.
TheFMUisnotdirectlyconnectedtotheRRU.
Therefore,setthisparametertothecabinet
numberoftheBBUorCCUthatconnectstothe
FMU.
ThemanageroftheFMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothesubrack
numberoftheBBU,CCU,orRRU.
MSRN
TheFMUisnotdirectlyconnectedtotheRRU.
Therefore,setthisparametertothesubrack
numberoftheBBUorCCUthatconnectstothe
FMU.
Network
plan
Network
plan
Thisparameterspecifiesthenumberoftheserial
portonthemanagertowhichtheFMUis
connected.
ManagerPort
No.
MPN
IftheFMUisconnectedtotheBBU:
UPEU/UEIU(MON1):1
Network
plan
UPEU/UEIU(MON0):0
IftheFMUisconnectedtotheCCU,itmustbe
connectedtoportD_COM1.Setthisparameterto1.
Thisparameterspecifiesthecommunication
addressoftheFMU.AmaximumoftwoFMUs
canbeconfiguredonanRS485bus.
Address
ADDR
Setthisparameterasfollows:
Network
plan
UpperlevelFMUintwocascadedFMUs:14
LowerlevelFMUintwocascadedFMUs:15
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
SpecialBoolean
AlarmFlag
SBAF
Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled)andSS_DISABLE(Smog
SensorDisabled).
ItisrecommendedthattheFMUnotbe
connectedtoexternalsensorsandallsensorsbe
disabled.Ifyouwanttousethesensors,contact
Huaweitechnicalsupport.
Retainthedefaultsettings,whichmeanthatall
sensorsaredisabled.
Network
plan
Thisparameterspecifieswhethertoenablesmart
temperaturecontrol.
Smart
Temperature
Control
WhenthisparameterissettoENABLED,the
cabinetadjuststhefanspeedaccordingtothe
TRXtemperature.Inthismode,thefannoiseis
low.
STC
WhenthisparameterissettoDISABLED,the
cabinetadjuststhefanspeedaccordingtothe
temperatureattheairintakevent.Inthismode,
thefannoiseishigh.
Network
plan
ThisparametercanbesettoDISABLEDor
ENABLED.
ENABLEDisrecommended.
Thisparameterspecifieswhichmodeisusedto
adjustthefanspeed.
Valuerange:0to65535
0:defaultmode.Thismodeachievesatradeoff
amongpowerconsumption,noise,and
temperaturecontrol.Itappliestomost
scenarios.
9:synchronizationmode.Thismodebringslow
noisebutpoortemperaturecontroleffects.
Inappropriateuseofthismodemayleadto
seriousresults,forexample,theservicesonthe
RFmoduleareinterrupteddueto
overtemperature.ContactHuaweitechnical
supportbeforeusingthismode.
Temperature
ControlMode
TCMODE
Othervalues:Thedefaultmodetakeseffect.
Network
Plan
Scenario3:ConfiguringtheTCU
Table44describestheparametersettingsfortheTCU.
Table44ParametersettingsfortheTCU
Parameter
Name
Parameter
ID
SettingDescription
Source
Thisparameterspecifiesthenumberofthe
cabinethousingtheTCU.
CabinetNo.
SubrackNo.
CN
SRN
IfthenumberoftheAPM30Hcabinethousingthe
TCUis0,setthisparameterto0.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberofthe
subrackhousingtheTCU.
Setthisparameterto8or14.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Network
plan
Network
plan
Thisparameterspecifiesthenumberoftheslot
housingtheTCU.
IftheTCUisinstalledintheBTS3900ALAC,
BTS3900ALDC,IBBS700D,orIBBS700T
cabinet,setthisparameterasfollows:
SettheslotnumberoftheCMUFto0.
SettheslotnumberofHAU0to1.
SettheslotnumberofHAU1to2.
SlotNo.
SN
IftheTCUisinstalledintheTP48600Acabinet,
setthisparameterasfollows:
Network
plan
SettheslotnumberoftheCMUFforcabinet
temperaturecontrolto0.
SettheslotnumberoftheCMUFforbattery
cabinettemperaturecontrolto1.
SettheslotnumberofHAU0to2.
SettheslotnumberofHAU1to3.
IftheTCUisinstalledonothercabinet,setthis
parameterto0.
Manager
CabinetNo.
Manager
SubrackNo.
MCN
ThemanageroftheTCUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothecabinet
numberoftheBBU,CCU,orRRU.
Network
plan
MSRN
ThemanageroftheTCUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothesubrack
numberoftheBBU,CCU,orRRU.
Network
plan
Thisparameterspecifiesthenumberoftheserial
portonthemanagertowhichtheTCUis
connected.
Setthisparameterasfollows:
IftheTCUisconnectedtotheBBU:
UPEU/UEIU(MON1):1
ManagerPort
No.
MPN
UPEU/UEIU(MON0):0
IftheTCUisconnectedtotheCCU:
CMUFispermanentlyconnectedtoport
D_COM0,setthisparameterto0
FAU0andFAU1arepermanentlyconnectedto
portD_COM3,setthisparameterto3
IftheTCUisconnectedtotheRRU,setthis
parameterto0.
Thisparameterspecifiesthecommunication
addressoftheTCU.
IntheAPM30HorTMC11Hcabinet,amaximum
oftwoTCUscanbeconfiguredonanRS485bus.
Setthisparameterasfollows:
UpperlevelTCUintwocascadedTCUs:7
LowerlevelTCUintwocascadedTCUs:6
Network
plan
IntheIBBS200D/IBBS200Tcabinet,amaximum
offourTCUscanbeconfiguredonanRS485
bus.
Setthisparameterasfollows:
IftheupperlevelTCUismanagedbythePMU
whosecommunicationaddressis3,setthis
parameterto23.IfthelowerlevelTCUis
managedbythisPMU,setthisparameterto24.
Address
ADDR
Network
plan
IftheupperlevelTCUismanagedbythePMU
whosecommunicationaddressis4,setthis
parameterto25.IfthelowerlevelTCUis
managedbythisPMU,setthisparameterto26.
IftheHAUsareinstalled,amaximumoftwo
TCUscanbeconfiguredonanRS485bus.
Setthisparameterasfollows:
UpperlevelTCUintwocascadedTCUs:28
LowerlevelTCUintwocascadedTCUs:29
IftheCMUFisinstalled,onlyoneTCUcanbe
configuredonanRS485bus.Setthisparameter
to7.
Temperature
AlarmLower
Threshold
TLTHD
Thisparameterspecifiesthelowertemperature
limitforthecabinet.Ifthetemperatureexceeds
thelowerlimit,theNodeBoreNodeBreportsthe
alarmALM25652CabinetTemperature
Unacceptable.
Network
plan
Thedefaultvalueisrecommendedforthis
parameter.
Temperature
AlarmUpper
Threshold
TUTHD
Thisparameterspecifiestheuppertemperature
limitforthecabinet.Ifthetemperatureexceeds
theupperlimit,theNodeBoreNodeBreportsthe
alarmALM25652CabinetTemperature
Unacceptable.
Setthisparameterto50fortheTCUintheBBC.
Network
plan
Setthisparameterto68fortheTCUinother
cabinets.
SpecialBoolean
AlarmFlag
SBAF
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled)andSS_DISABLE(Smog
SensorDisabled).
ItisrecommendedthattheTCUnotbe
connectedtoexternalsensorsandallsensorsbe
disabled.Ifyouwanttousethesensors,contact
Huaweitechnicalsupport.
Network
plan
Retainthedefaultsettings,whichmeanthatall
sensorsaredisabled.
Scenario4:ConfiguringtheCCU
Table45describestheparametersettingsfortheCCU.
Table45ParametersettingsfortheCCU
ParameterName
Parameter
ID
SettingDescription
Source
Thisparameterspecifiesthenumberofthe
cabinethousingtheCCU.
IfthenumberoftheBTS3900ALcabinet
housingtheCCUis0,setthisparameterto0.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Network
plan
CabinetNo.
CN
SubrackNo.
SRN
Thisparameterspecifiesthenumberofthe
subrackhousingtheCCU.Setthisparameterto
thedefaultvalue15.
Network
plan
SlotNo.
SN
Thisparameterspecifiesthenumberoftheslot
housingtheCCU.
Setthisparametertothedefaultvalue0.
Network
plan
ManagerCabinet
No.
MCN
ThemanageroftheCCUisgenerallytheBBU
orRRU.Setthisparametertothecabinet
numberoftheBBUorRRU.
TheCCUcanonlybemanagedbytheBBU.
Network
plan
ManagerSubrack
No.
MSRN
ThemanageroftheCCUisgenerallytheBBU
orRRU.Setthisparametertothesubrack
numberoftheBBUorRRU.
TheCCUcanonlybemanagedbytheBBU.
Network
plan
ManagerPortNo.
MPN
Thisparameterspecifiesthenumberofthe
serialportonthemanagertowhichtheCCUis
connected.
TheCCUmustbeconnectedtoportMON0on
theBBU.Therefore,thisparametermustbeset
to0.
Network
plan
ThisparameterspecifieswhethertheCCUis
directlyconnectedtoitsmanager.
DirectConnectFlag
CascadeNo.
Connected
Standard
SpecialBoolean
AlarmFlag
DCF
IftheCCUisdirectlyconnectedtoitsmanager,
setthisparametertoYES.
IftheCCUisconnectedtoitsmanagerovera
cascadingCCU,setthisparametertoNO.
Network
plan
CCN
Thisparameterspecifiestheinsertedpositionof
theCCUonaCCUcascadedlink.Setthis
parameterto1fortheleftmostCCUonthelink
(theCCUwhoseportFE_Lisnotconnected).
Setthisparametertoanintegerinascending
orderfortheotherCCUsonthelink.
Network
plan
CS
Thisparameterspecifiesthenetwork
technologytypeoftheBBUthatisdirectly
connectedtotheCCU.Setthisparameterto
GSM,UMTS,orLTE.
TheparameterisvalidonlywhentheDCFisset
toYes.
Network
plan
SBAF
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled)andSS_DISABLE(Smog
SensorDisabled).
ItisrecommendedthattheCCUnotbe
connectedtoexternalsensorsandallsensors
bedisabled.Ifyouwanttousethesensors,
contactHuaweitechnicalsupport.
Network
plan
Retainthedefaultsettings,whichmeanthatthe
watersensorandsmokesensoraredisabled.
Scenario6:ConfiguringCustomizedAlarms
Topreparedataforcustomizedalarmconfiguration,performthefollowingsteps:
Step1PrepareEMUconfigurationdata.
Beforedatapreparation,checkwhethertheEMUneedstobeconfiguredbyreferringtoTable42.IftheEMUisrequired,prepareEMU
configurationdatabyreferringtoTable46.Otherwise,skipthisstep.
Step2Prepareconfigurationdataofthealarmsignalinputandoutputportsbasedontheinputandoutputrequirementsofcustomized
alarms.
PrepareconfigurationdataoftheenvironmentalalarmsignalinputportALMPORTbyreferringtoTable47.
PrepareconfigurationdataoftheenvironmentalalarmsignaloutputportOUTPORTbyreferringtoTable48.
End
Table46ParametersettingsfortheEMU
Parameter
Name
Parameter
ID
SettingDescription
Source
CabinetNo.
CN
Thisparameterspecifiesthenumberofthe
cabinethousingtheEMU.
Network
plan
SubrackNo.
SRN
Thisparameterspecifiesthenumberofthe
subrackhousingtheEMU.
Setthisparametertothedefaultvalue.
Network
plan
SlotNo.
SN
Thisparameterspecifiesthenumberoftheslot
housingtheEMU.
Setthisparametertothedefaultvalue.
Network
plan
Manager
CabinetNo.
MCN
ThemanageroftheEMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothecabinet
numberoftheBBU,CCU,orRRU.
Network
plan
Manager
SubrackNo.
MSRN
ThemanageroftheEMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothesubrack
numberoftheBBU,CCU,orRRU.
Network
plan
Thisparameterspecifiesthenumberoftheserial
portonthemanagertowhichtheEMUis
connected.Setthisparameterasfollows:
IftheEMUisconnectedtotheBBU:
ManagerPort
No.
UPEU/UEIU(MON1):1
MPN
UPEU/UEIU(MON0):0
Network
plan
IftheEMUisconnectedtotheCCU,itmustbe
connectedtoportD_COM3.Setthisparameterto
3.
IftheEMUisconnectedtotheRRU,setthis
parameterto0.
Address
Temperature
AlarmLower
Threshold
ADDR
TLTHD
Thisparameterspecifiesthecommunication
addressoftheEMU.
Setthisparameterto2.
Thisparameterspecifiesthelowerambient
temperaturelimit.Iftheambienttemperature
exceedsthelowerlimit,theNodeBoreNodeB
reportsthealarmALM25650Ambient
TemperatureUnacceptable.
Thisparameterneedstobeconfiguredonlywhen
TS_DISABLEinSAAFiscleared.
Network
plan
Network
plan
Thedefaultvalueisrecommendedforthis
parameter.
Temperature
AlarmUpper
Threshold
TUTHD
Thisparameterspecifiestheupperambient
temperaturelimit.Iftheambienttemperature
exceedstheupperlimit,theNodeBoreNodeB
reportsthealarmALM25650Ambient
TemperatureUnacceptable.
Thisparameterneedstobeconfiguredonlywhen
TS_DISABLEinSAAFiscleared.
Network
plan
Thedefaultvalueisrecommendedforthis
parameter.
HumidityAlarm
Lower
Threshold
HLTHD
Thisparameterspecifiesthelowerambient
humiditylimit.Iftheambienthumidityexceedsthe
lowerlimit,theNodeBoreNodeBreportsthe
alarmALM25651AmbientHumidity
Unacceptable.
Thisparameterneedstobeconfiguredonlywhen
HS_DISABLEinSAAFiscleared.
Network
plan
Thedefaultvalueisrecommendedforthis
parameter.
HumidityAlarm
Upper
Threshold
HUTHD
Thisparameterspecifiestheupperambient
humiditylimit.Iftheambienthumidityexceedsthe
upperlimit,theNodeBoreNodeBreportsthe
alarmALM25651AmbientHumidity
Unacceptable.
Thisparameterneedstobeconfiguredonlywhen
HS_DISABLEinSAAFiscleared.
Network
plan
Thedefaultvalueisrecommendedforthis
parameter.
Thisparameterspecifieswhethertoreporta
dedicatedanalogalarm.Iftheshieldflagforan
analogalarmisselected,theanalogalarmcannot
bereported.
SpecialAnalog
Valuerange:48V_DISABLE(48Voltage
Disabled),RES0(ReservedSensor0),
RES1(ReservedSensor1),RES2(Reserved
Sensor2),TS_DISABLE(TemperatureSensor
Disabled),andHS_DISABLE(HumiditySensor
Disabled).
Network
AlarmFlag
SAAF
Setthisparameterasfollows:
The48Valarmisusedtocheckwhetherthe
inputvoltageforthecabinetisnormal.When
theinputvoltageforthecabinetis48V,itis
recommendedthat48V_DISABLEbecleared.
plan
RES0,RES1,andRES2areparameters
reservedbyHuaweiandtheyareselected.
SetTS_DISABLEandHS_DISABLEbasedon
thetypesofsensorsconnectedtotheEMUor
EMUA.
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
SpecialBoolean
AlarmFlag
SBAF
Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled),SS_DISABLE(SmogSensor
Disabled),IS_DISABLE(InfraredSensor
Disabled),andGS_DISABLE(GatingSensor
Disabled).
Network
plan
Itisrecommendedthatthisparameterbeset
basedonthetypesofsensorsconnectedtothe
EMUorEMUA.
Table47ParametersettingsfortheALMPORT
Parameter
Name
Parameter
ID
SettingDescription
Source
CabinetNo.
CN
Thisparameterspecifiesthecabinetnumberof
theboardwheretheALMPORTportislocated.
Network
plan
SubrackNo.
SRN
Thisparameterspecifiesthesubracknumberof
theboardwheretheALMPORTportislocated.
Network
plan
SlotNo.
SN
Thisparameterspecifiestheslotnumberofthe
boardwheretheALMPORTportislocated.
Network
plan
Thisparameterspecifiesthenumbersofthe
alarmportsoneachmonitoringboardasfollows:
PortNo.
PN
UPEU/UEIU:0to7(forBooleanalarms)
RRU:0to3(forBooleanalarms)
Network
plan
EMU/EMUA:0to31(forBooleanalarms)
EMU/EMUA:32to35(foranalogalarms)
Switch
AlarmID
SW
Ifacustomizedalarminputisrequired,theswitch
mustbeturnedon.Thisparameterspecifiesthe
stateoftheportswitchandcanbesetasfollows:
OFF(Off):indicatesthattheportisdisabledand
alarmscannotbedetected.Thisisthedefault
valueforthisparameter.
ON(On):indicatesthattheportisenabledand
alarmscanbereportedthroughtheport
accordingtothecustomizedalarmIDs.In
addition,thealarmvoltagelevelforBoolean
alarmsorthealarmupper/lowerlimitcanbeset
inthisparameter.
Network
plan
AID
ThisparameterspecifiesthealarmIDpertaining
tothealarmport.Ifanalarmisdetectedthrough
theport,thevalueofthisparameterisusedas
thealarmIDandisreportedwiththealarm.The
valuerangeofthisparameteris65033to65233.
Thealarmname,alarmseverity,andOSStype
correspondingtothealarmIDareconfiguredon
theM2000client.
Network
plan
Thisparameterspecifiesthetypeofanalarm
port.ItcanbesettoBOOL(DigitalPort)or
VALUE(AnalogPort).
PortType
PT
Ananalogport,providedbytheEMUorEMUA,
monitorstheexternalenvironment.
Adigitalport,providedbytheUPEU,UEIU,RRU,
EMU,orEMUA,monitorstheexternal
environmentwithBooleanordiscretevalues.
ThisparameterisvalidonlywhenPTissetto
BOOL.
Network
plan
AlarmVoltage
AVOL
Thisparameterspecifieswhetherthesensor
sendstheportahighlevelorlowlevelalarm.Set
thisparameterbasedonalarmcableconnection.
Fordetailsaboutthepinassignmentforthewires
ofalarmcables,see:
Section"BBUAlarmCable"inthebasestation
specifichardwaredescription.
Network
plan
Section"RRUAlarmCable"intheRRUspecific
hardwaredescription.
Section"RS485SerialPort"inEMUUserGuide
andEMUAUserGuide.
AlarmUpper
Limit
UL
Thisparameterspecifiesthealarmupperlimit.If
theenvironmentmeasurementvalueisgreater
thanthealarmupperlimitofthesensor,the
NodeBoreNodeBreportsthealarm.
Environmentmeasurementvalue=Measurement
lowerlimit+(Measurementupperlimit
Measurementlowerlimit)x(Observedcurrentor
voltageOutputlowerlimit)/(Outputupperlimit
Outputlowerlimit).
ULmustbesmallerthanorequaltoSMULand
greaterthanLL.
Network
plan
Thisparameterspecifiesthealarmlowerlimit.If
theenvironmentmeasurementvalueissmaller
thanthealarmlowerlimitofthesensor,the
NodeBoreNodeBreportsthealarm.
AlarmLower
Limit
SensorType
Sensor
Measurement
UpperLimit
LL
ST
SMUL
Environmentmeasurementvalue=Measurement
lowerlimit+(Measurementupperlimit
Measurementlowerlimit)x(Observedcurrentor
voltageOutputlowerlimit)/(Outputupperlimit
Outputlowerlimit).
LLmustbegreaterthanorequaltoSMLLand
smallerthanUL.
Thisparameterspecifiesthetypeofasensor.
SetthisparametertoVOLTAGE(VoltageType)
orCURRENT(CurrentType)basedonthe
externalsensorspecifications.
ThisparameterisvalidonlywhenPTissetto
VALUE.
Thisparameterspecifiesthemeasurementupper
limitoftheanalogport.Setthisparameterbased
onthesiteconditions,suchasthetemperature
andhumidity.
SMULmustbegreaterthanorequaltoUL.
Network
plan
Network
plan
Network
plan
SMULmustbegreaterthanSMLL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
Sensor
Measurement
LowerLimit
SMLL
Thisparameterspecifiesthemeasurementlower
limitoftheanalogport.Setthisparameterbased
onthesiteconditions,suchasthetemperature
andhumidity.
SMLLmustbesmallerthanorequaltoLL.
Network
plan
SMLLmustbesmallerthanSMUL.
SensorOutput
UpperLimit
SensorOutput
LowerLimit
SOUL
ThisparameterisvalidonlywhenPTissetto
VALUE.
Thisparameterspecifiestheoutputsignalupper
limitoftheanalogport.Forasensorofeitherthe
currenttypeorthevoltagetype,setthis
parameterbasedontheexternalsensor
specifications.
SOULmustbegreaterthanSOLL.
Network
plan
SOLL
ThisparameterisvalidonlywhenPTissetto
VALUE.
Thisparameterspecifiestheoutputsignallower
limitoftheanalogport.Forasensorofeitherthe
currenttypeorthevoltagetype,setthis
parameterbasedontheexternalsensor
specifications.
SOLLmustbesmallerthanSOUL.
Network
plan
Table48ParametersettingsfortheOUTPORT
Parameter
Name
Parameter
ID
SettingDescription
Source
CabinetNo.
CN
Thisparameterspecifiesthecabinetnumberof
theboardwheretheOUTPORTportislocated.
Network
plan
SubrackNo.
SRN
Thisparameterspecifiesthesubracknumberof
theboardwheretheOUTPORTportislocated.
Network
plan
SlotNo.
SN
Thisparameterspecifiestheslotnumberofthe
boardwheretheOUTPORTportislocated.
Network
plan
PortNo.
PN
Valuerange:0to5
Network
plan
PortName
NAME
Theconfigurationofthisparameterisoptional.If
configured,thisparametercanbecustomized.
Network
plan
PortSwitch
Thisswitchisturnedonbasedonthemonitoring
deviceconfiguration.
SW
Toenableaport,setthisparametertoON.
Todisableaport,setthisparametertoOFF.
Network
plan
ReferenceforConfiguringtheMonitoringFunction
Themonitoringfunctionshouldbeconfiguredbasedonthehardwareinstalledinacabinet.Thissectiondescribeshowtoconfigurethe
monitoringfunctionintypicalbasestationcabinets.Monitoringfunctionconfigurationsinvolvethesettingsofparameterssuchas
cabinetnumber,subracknumber,slotnumber,boardtype,cabinetnumberofaboardmanager,subracknumberofaboardmanager,
serialportnumber,andcommunicationaddress.Fordetailsaboutthesettingsofotherparameters,seesection"Scenariospecific
Data."
ThissectiondescribestheconfigurationsintheVer.CcabinetsfortheBTS3900andBTS3900L.TheconfigurationsintheVer.Bcabinetsarethesameas
thoseintheVer.Ccabinets,exceptthattheFMUEisreplacedwiththeFMUC.TheconfigurationsintheVer.DcabinetsarethesameasthoseintheVer.C
cabinets,exceptthattheFMUEisreplacedwiththeFMUEA.
ThissectionalsodescribestheconfigurationsintheVer.CcabinetsfortheBTS3900AandDBS3900.TheconfigurationsintheVer.Bcabinetsarethesameas
thoseintheVer.Ccabinets,exceptthattheCMUEisreplacedwiththeCMUA.TheconfigurationsintheVer.DcabinetsarethesameasthoseintheVer.C
cabinets,exceptthattheCMUEisreplacedwiththeCMUEAandnoHPMIisconfigured.
Scenario1:ExampleofConfigurationsinaBTS3900(48VDC)
Figure41showstheconnectionsofmonitoringsignalcablesinaBTS3900(48VDC)housedintwocabinets.
Figure41ConnectionsofmonitoringsignalcablesinaBTS3900(48VDC)
Table49describestheconfigurationsofmonitoringboardsinaBTS3900(48VDC).
Table49ConfigurationsofmonitoringboardsinaBTS3900(48VDC)
Cabinet
Cabinet0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Remarks
BTS3900
50
GATM0
22
ForBTS
only
51
GATM1
22
ForBTS
only
11
FMU
14
FMUE
40
EMU
EMU,
optional
Cabinet1
BTS3900
11
FMU
15
FMUE
Scenario2:ExampleofConfigurationsinaBTS3900(AC)
Figure42showstheconnectionsofmonitoringsignalcablesinaBTS3900(AC)housedintwocabinets.
Figure42ConnectionsofmonitoringsignalcablesinaBTS3900(AC)
Table410describestheconfigurationsofmonitoringboardsinaBTS3900(AC)housedintwocabinets.
Table410ConfigurationsofmonitoringboardsinaBTS3900(AC)
Cabinet
Cabinet0
Cabinet1
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
BTS3900
PMU
11
FMU
14
40
EMU
EMU,optional
11
FMU
15
PMU
BTS3900
Scenario3:ExampleofConfigurationsinaBTS3900L(48VDC)
Figure43_Ref313028199showstheconnectionsofmonitoringsignalcablesinaBTS3900L(48VDC)cabinet.
Figure43ConnectionsofmonitoringsignalcablesinaBTS3900L(48VDC)
Table411describestheconfigurationsofmonitoringboardsinaBTS3900L(48VDC)cabinet.
Table411ConfigurationsofmonitoringboardsinaBTS3900L(48VDC)
Cabinet
Cabinet0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
BTS3900L
40
EMU
EMU,optional
50
GATM0
22
ForBTSonly
51
GATM1
22
ForBTSonly
11
FMU
14
12
FMU
15
Scenario4:ExampleofConfigurationsinaBTS3900A(AC)
Figure44showstheconnectionsofmonitoringsignalcablesinaBTS3900A(AC)housedinoneAPM30Hcabinet,oneRFCcabinet,
twoIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure44ConnectionsofmonitoringsignalcablesinaBTS3900A(1APM30H+1RFC+2IBBS200D/IBBS200T+1TMC11H)
Table412describestheconfigurationsofmonitoringboardsinaBTS3900A(AC)housedinoneAPM30Hcabinet,oneRFCcabinet,
twoIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table412ConfigurationsofmonitoringboardsinaBTS3900A(1APM30H+1RFC+2IBBS200D/IBBS200T+1TMC11H)
Cabinet
APM30H0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
APM30
TCU
CMUE
PMU
50
GATM0
22
ForBTSonly
51
GATM1
22
ForBTSonly
40
EMU
EMUA,
optional
RFC0
RFC
11
FMU
14
CMUE
TMC11H0
TMC
TCU
CMUE
IBBS200D/IBBS200T0
BBC
TCU
23
CMUE
IBBS200D/IBBS200T1
BBC
10
TCU
24
CMUE
Figure45showstheconnectionsofmonitoringsignalcablesinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
andtwoIBBS200D/IBBS200Tcabinets.
Figure45ConnectionsofmonitoringsignalcablesinaBTS3900A(2APM30H+2RFC+2IBBS200D/IBBS200T)
Table413describestheconfigurationsofmonitoringboardsinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
andtwoIBBS200D/IBBS200Tcabinets.
Table413ConfigurationsofmonitoringboardsinaBTS3900A(2APM30H+2RFC+2IBBS200D/IBBS200T)
Cabinet
APM30H0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
APM30
PMU
TCU
CMUE
50
GATM0
22
ForBTSonly
51
GATM1
22
ForBTSonly
40
EMU
EMUA,
optional
RFC0
RFC
11
FMU
14
CMUE
RFC1
RFC
11
FMU
15
CMUE
APM30H0
APM30
PMU
TCU
CMUE
IBBS200D/IBBS200T0
BBC
TCU
23
CMUE
IBBS200D/IBBS200T2
BBC
11
TCU
23
CMUE
Figure46showstheconnectionsofmonitoringsignalcablesinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
fourIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure46ConnectionsofmonitoringsignalcablesinaBTS3900A(2APM30H+2RFC+4IBBS200D/IBBS200T+1TMC11H)
Table414describestheconfigurationsofmonitoringboardsinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
fourIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table414ConfigurationsofmonitoringboardsinaBTS3900A(2APM30H+2RFC+4IBBS200D/IBBS200T+1TMC11H)
Cabinet
APM30H0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
APM30
PMU
TCU
CMUE
50
GATM0
22
ForBTSonly
51
GATM1
22
ForBTSonly
40
EMU
EMUA,
optional
RFC0
RFC
11
FMU
14
CMUE
RFC1
RFC
11
FMU
15
CMUE
APM30H1
APM30
PMU
TCU
CMUE
TMC11H0
TMC
TCU
IBBS200D/IBBS200T0
BBC
TCU
23
CMUE
IBBS200D/IBBS200T1
BBC
10
TCU
24
CMUE
IBBS200D/IBBS200T2
BBC
11
TCU
23
CMUE
IBBS200D/IBBS200T3
BBC
12
TCU
24
CMUE
Scenario5:ExampleofConfigurationsinaBTS3900A(48VDC)
Figure47showstheconnectionsofmonitoringsignalcablesinaBTS3900A(48VDC)housedintwoTMC11HcabinetsandtwoRFC
cabinets.IfcabinetTMC11H1isnotconfigured,connecttheCMUEincabinetRFC0totheCMUEincabinetRFC1.Ignorethe
configurationdataofcabinetTMC11H1inTable415.
Figure47ConnectionsofmonitoringsignalcablesinaBTS3900A(2TMC11H+2RFC)
Table415describestheconfigurationsofmonitoringboardsinaBTS3900AhousedintwoTMC11HcabinetsandtwoRFCcabinets.
Table415ConfigurationsofmonitoringboardsinaBTS3900A(2TMC11H+2RFC)
Cabinet
TMC11H0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
TMC
TCU
CMUE
50
GATM0
22
ForBTSonly
51
GATM1
22
ForBTSonly
40
EMU
EMUA,
optional
RFC0
RFC
11
FMU
14
CMUE
RFC1
RFC
11
FMU
15
CMUE
TMC11H1
TMC
TCU
CMUE
Scenario6:ExampleofConfigurationsinaDBS3900(AC)
Figure48showstheconnectionsofmonitoringsignalcablesinaDBS3900(AC)housedintwoAPM30Hcabinets,two
IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure48ConnectionsofmonitoringsignalcablesinaDBS3900(2APM30H+2IBBS200D/IBBS200T+1TMC11H)
Table416describestheconfigurationsofmonitoringboardsinaDBS3900(AC)housedintwoAPM30Hcabinets,two
IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table416ConfigurationsofmonitoringboardsinaDBS3900(2APM30H+2IBBS200D/IBBS200T+1TMC11H)
Cabinet
APM30H0
APM30H1
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
APM30
PMU
TCU
CMUE
40
EMU
EMUA,
optional
PMU
TCU
CMUE
APM30
TMC11H0
TMC
TCU
CMUE
IBBS200D/IBBS200T0
BBC
TCU
23
CMUE
IBBS200D/IBBS200T2
BBC
11
TCU
23
CMUE
Figure49showstheconnectionsofmonitoringsignalcablesinaDBS3900(AC)housedintwoAPM30Hcabinets,four
IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure49ConnectionsofmonitoringsignalcablesinaDBS3900(2APM30H+4IBBS200D/IBBS200T+1TMC11H)
Table417describestheconfigurationsofmonitoringboardsinaDBS3900(AC)housedintwoAPM30Hcabinets,four
IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table417ConfigurationsofmonitoringboardsinaDBS3900(2APM30H+4IBBS200D/IBBS200T+1TMC11H)
Cabinet
APM30H0
APM30H1
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
APM30
PMU
TCU
CMUE
40
EMU
EMUA,
optional
PMU
TCU
CMUE
APM30
TMC11H0
TMC
TCU
CMUE
IBBS200D/IBBS200T0
BBC
TCU
23
CMUE
IBBS200D/IBBS200T1
BBC
10
TCU
24
CMUE
IBBS200D/IBBS200T2
BBC
11
TCU
23
CMUE
IBBS200D/IBBS200T3
BBC
12
TCU
24
CMUE
Figure410showstheconnectionsofmonitoringsignalcablesinaDBS3900intheremotemonitoringscenario.
Figure410ConnectionsofmonitoringsignalcablesinaDBS3900intheremotemonitoringscenario
Table418describestheconfigurationsofmonitoringboardsinaDBS3900intheremotemonitoringscenario.
Table418ConfigurationsofmonitoringboardsinaDBS3900intheremotemonitoringscenario
Cabinet
APM30H0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
APM30
10
PMU
Cabinet
numberof
theRRU
that
connects
tothis
PMU
Subrack
numberof
theRRU
that
connects
tothis
PMU
10
TCU
Cabinet
numberof
theRRU
that
connects
tothis
TCU
Subrack
numberof
theRRU
that
connects
tothis
TCU
CMUE
10
40
EMU
Cabinet
numberof
theRRU
that
connects
tothis
Subrack
numberof
theRRU
that
connects
tothis
EMU
EMU
IBBS200D/IBBS200T0
BBC
11
TCU
Cabinet
numberof
theRRU
that
connects
tothis
TCU
Subrack
numberof
theRRU
that
connects
tothis
TCU
23
CMUE
IBBS200D/IBBS200T1
BBC
12
TCU
Cabinet
numberof
theRRU
that
connects
tothis
TCU
Subrack
numberof
theRRU
that
connects
tothis
TCU
24
CMUE
Figure411showstheconnectionsofmonitoringsignalcablesinaDBS3900(AC)thathastheBBUinstalledinanOMBcabinet.
Figure411ConnectionsofmonitoringsignalcablesinaDBS3900(1OMB)
Table419describestheconfigurationsofmonitoringboardsinaDBS3900(AC)thathastheBBUinstalledinanOMBcabinet.
Table419ConfigurationsofmonitoringboardsinaDBS3900(1OMB)
Cabinet
OMB
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
OMB
PMU
TCU
HEUA
Figure412showstheconnectionsofmonitoringsignalcablesinaDBS3900(110V/220VAC)deployedinBBU+RRU+ICRmode.The
BBUandPMUareinstalledontheupperandlowerracksrespectivelyinanIMBcabinet.
Figure412ConnectionsofmonitoringsignalcablesinaDBS3900(BBU+RRU+ICR)
Table420describestheconfigurationsofmonitoringboardsinaDBS3900(110V/220VAC)deployedinBBU+RRU+ICRmode.
Table420ConfigurationsofmonitoringboardsinaDBS3900(BBU+RRU+ICR)
Cabinet
IMB03
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
Virtual
PMU
Figure413showstheconnectionsofmonitoringsignalcablesinaDBS3900(110V/220VAC)deployedinBBU+RRU+IMBmode.The
BBUisinstalledinanIMBcabinetandtheRRUisinstalledoutdoors.
Figure413ConnectionsofmonitoringsignalcablesinaDBS3900(BBU+RRU+IMB)
Table421describestheconfigurationsofmonitoringboardsinaDBS3900(110V/220VAC)deployedinBBU+RRU+IMBmode.
Table421ConfigurationsofmonitoringboardsinaDBS3900(BBU+RRU+IMB)
Cabinet
IMB03
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
Virtual
PMU
Scenario7:ExampleofConfigurationsinaDBS3900(48VDC)
Figure414showstheconnectionsofmonitoringsignalcablesinaDBS3900(48VDC)housedintwoTMC11Hcabinets.
Figure414ConnectionsofmonitoringsignalcablesinaDBS3900(2TMC11H)
Table422describestheconfigurationsofmonitoringboardsinaDBS3900(48VDC)housedintwoTMC11Hcabinets.
Table422ConfigurationsofmonitoringboardsinaDBS3900(2TMC11H)
Cabinet
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
TMC11H0
TMC
TCU
CMUE
TMC11H1
TMC
TCU
CMUE
Figure415showstheconnectionsofmonitoringsignalcablesinaDBS3900(48VDC)thathastheBBUinstalledinanOMBcabinet.
Figure415ConnectionsofmonitoringsignalcablesinaDBS3900(1OMB)
Table423describestheconfigurationsofmonitoringboardsinaDBS3900(48VDC)thathastheBBUinstalledinanOMBcabinet.
Table423ConfigurationsofmonitoringboardsinaDBS3900(1OMB)
Cabinet
OMB
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Note
OMB
TCU
HEUA
Scenario8:ExampleofConfigurationsinaBTS3900AL(AC)
Figure416showstheconnectionsofmonitoringsignalcablesinaBTS3900AL(AC)housedinoneACcabinet,oneDCcabinet,and
oneTMC11Hcabinet.IftheHAUsarenotconfigured,connecttheCMUAdirectlytoportD_COM3ontheCCU.IgnoretheHAU
configurationdataofcabinetBTS3900ALAC0inTable424Figure417Table425.
Figure416ConnectionsofmonitoringsignalcablesinaBTS3900AL(1ACcabinet+1DCcabinet+1TMC11H)
Table424describestheconfigurationsofmonitoringboardsinaBTS3900AL(1ACcabinet+1DCcabinet+1TMC11H)
Table424ConfigurationsofmonitoringboardsinaBTS3900AL(1ACcabinet+1DCcabinet+1TMC11H)
Cabinet
BTS3900AL
AC0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Otherparameter
Note
BTS3900AL
15
CCU
21
Level1whose
DirectConnectFlag
issettoYES.
Connectednetwork
technologytype:
networkservedby
theentireCCUlink
BTS3900AL
DC0
TMC11H
(Ver.C)0
BTS3900AL
TCU
15
CMUF
BTS3900AL
11
FMU
15
14
FAU
BTS3900AL
PMU
15
BTS3900AL
TCU
15
28
HAU0,
optional
BTS3900AL
TCU
15
29
HAU1,
optional
BTS3900AL
40
EMU
15
EMU,
optional
BTS3900AL
15
CCU
21
Level2whose
DirectConnectFlag
issettoNO
BTS3900AL
TCU
15
CMUF
BTS3900AL
11
FMU
15
14
FAU
BTS3900AL
TCU
15
28
HAU0,
optional
BTS3900AL
TCU
15
29
HAU1,
optional
TMC
TCU
15
CMUE
Figure417showstheconnectionsofmonitoringsignalcablesinaBTS3900AL(AC)housedinoneACcabinet,oneDCcabinet,and
oneIBBS700D/IBBS700Tcabinet.
Figure417ConnectionsofmonitoringsignalcablesinaBTS3900AL(1ACcabinet+1DCcabinet+1IBBS700D/IBBS700T)
Table425describestheconfigurationsofmonitoringboardsinaBTS3900AL(AC)housedinoneACcabinet,oneDCcabinet,and
oneIBBS700D/IBBS700Tcabinet.
Table425ConfigurationsofmonitoringboardsinaBTS3900AL(1ACcabinet+1DCcabinet+1IBBS700D/IBBS700T)
Cabinet
BTS3900ALAC0
Cabinet
Type
MonitoringBoardConfiguration
CN
SRN
SN
BT
MCN
MSRN
MPN
ADDR
Otherparameter
Note
BTS3900AL
15
CCU
21
Level1whose
DirectConnectFlag
issettoYES.
Connectednetwork
technologytype:
networkservedby
theentireCCUlink
BTS3900ALDC0
IBBS700D/IBBS700T0
4.4.4Precautions
BTS3900AL
TCU
15
CMUF
BTS3900AL
11
FMU
15
14
FAU
BTS3900AL
PMU
15
BTS3900AL
TCU
15
28
HAU0,
optional
BTS3900AL
TCU
15
29
HAU1,
optional
BTS3900AL
40
EMU
15
EMU,
optional
BTS3900AL
15
CCU
21
Level2whose
DirectConnectFlag
issettoNO
BTS3900AL
TCU
15
CMUF
BTS3900AL
11
FMU
15
14
FAU
BTS3900AL
TCU
15
28
HAU0,
optional
BTS3900AL
TCU
15
29
HAU1,
optional
BBC
15
CCU
21
Level3whose
DirectConnectFlag
issettoNO
BBC
TCU
15
CMUF
BBC
TCU
15
28
HAU0,
optional
BBC
TCU
15
29
HAU1,
optional
N/A
4.4.5HardwareInstallation
Seesection"InstallingMonitoringSignalCables"inthebasestationspecificinstallationguide.
WhensettingexternalBooleanalarmsbasedonthehighorlowvoltagesettings,seethefollowingsectionstoobtainthepinassignment
forthewiresofalarmcables:
Section"BBUAlarmCable"inthebasestationspecifichardwaredescription.
Section"RRUAlarmCable"intheRRUspecifichardwaredescription.
Section"RS485SerialPort"inEMUUserGuideandEMUAUserGuide.
4.4.6FeatureActivation/InitialConfiguration
Thescenariosforconfiguringmonitoringmanagementcanbeusedtogether.Iftheyareusedtogether,dataforallthesescenarios
mustbeconfigured.Thereisnofixedsequencebetweentheconfigurationscenarios.WhentheEMUorEMUAisinstalledfor
configuringcustomizedalarms,configuretheEMU,andthentheALMPORTorOUTPORT.
ConfiguringaSingleNodeBoreNodeBontheGUI
ConfigureasingleNodeBoreNodeBontheGUIbasedonprepareddata.
ToconfigurethemonitoringfunctionforaNodeB,seesection"ConfiguringaNodeB(GUIMode)>ConfiguringDeviceDataAbouta
NodeB>ConfiguringMonitoringUnits>Procedure"in3900SeriesBaseStationInitialConfiguration(SRAN7.0)>NodeBInitial
Configuration(V200R014).
ToconfigurethemonitoringfunctionforaneNodeB,seesection"InitiallyConfiguringaSingleeNodeBontheCMEGUI>Configuring
eNodeBData>ConfiguringeNodeBDeviceData>ConfiguringMonitoringUnits>ProcedureineNodeBInitialConfigurationGuideor
in3900SeriesBaseStationInitialConfiguration(SRAN7.0)>eNodeBInitialConfiguration(V100R005).
ConfiguringNodeBsoreNodeBsinBatches
SavetheprepareddataofaNodeBoreNodeBasatemplate.ConfigureNodeBsoreNodeBsinbatchesontheGUIbyimportingthe
template.Fordetails,see:
ToconfigurethemonitoringfunctionforNodeBs,seesection"ConfiguringaNodeB(IubCollaborationMode)"in3900SeriesBase
StationInitialConfiguration(SRAN7.0)>NodeBInitialConfiguration(V200R014).
ToconfigurethemonitoringfunctionforeNodeBs,seesection"InitiallyConfiguringeNodeBsinBatches"ineNodeBInitial
ConfigurationGuideorin3900SeriesBaseStationInitialConfiguration(SRAN7.0)>eNodeBInitialConfiguration(V100R005).
ConfiguringaSingleNodeBoreNodeBUsingMMLCommands
Scenario1:ConfiguringthePMU
FordetailsabouthowtoconfigurethePMU,seePowerManagementFeatureParameterDescription.
Scenario2:ConfiguringtheFMU
RuntheADDFMUcommandtoaddanFMU.
Scenario3:ConfiguringtheTCU
RuntheADDTCUcommandtoaddaTCU.
Scenario4:ConfiguringtheCCU
RuntheADDCCUcommandtoaddaCCU.
Scenario5:ConfiguringCustomizedAlarms
Step1(Optional)RuntheADDEMUcommandtoaddanEMU.IftheEMUisnotrequired,skipthisstep.
Step2RuntheLSTALMPORTandLSTOUTPORTcommandstoquerythestatusoftheinputandoutputalarmports,respectively.
Step3Basedonthequeryresults,runthefollowingcommandstoopentheportthatneedstobeconfiguredasaninputalarmport
andclosetheunusedalarmport:
SETALMPORT:tosettheinputalarmport
SETOUTPORT:tosettheoutputalarmport
Step4Addandbindacustomizedalarm,andchangethealarmseverity.
AcustomizedalarmconfiguredontheNodeBoreNodeBmustbeaddedandboundtotheM2000sothatthealarmconsolecan
identifyandreportthealarm.
1.LogintotheM2000client.
2.ChooseMonitor>AlarmSetting>NEAlarmSetting.TheNEAlarmSettingwindowisdisplayed.
3.ChooseUserDefinedAlarm>AlarmDefinition.TheAlarmDefinitiontabpageisdisplayed.
Fordetails,seesection"FaultManagement>FaultMonitoring>DefininganNEAlarm"intheM2000documentation.
Ifyouconfiguretheoutputalarmport,youdonotneedtobindthealarmtotheM2000.
End
4.4.7Commissioning
N/A
4.4.8ActivationVerification
Toverifythemonitoringfunction,performthefollowingsteps:
Step1RunthefollowingMMLcommandstocheckwhetherthePMU,FMU,TCU,andEMUboardsareworkingproperly:
DSPPMU
DSPFMU
DSPTCU
DSPCCU
DSPEMU
Ifthesystemreturnsanycommandoutputforaboard,theboardisworkingproperly.Whenalltheboardsareworkingproperly,
proceedtoStep2.
Step2PerformtheoperationsdescribedinTable426andcheckwhetherambientalarmsarecorrectlyreported.Ifalarmscannotbe
reported,checkhardwareconnectionsandsoftwareconfigurations.
Table426Verifyingmonitoringalarms
AlarmID
AlarmName
AlarmTriggeringMethod
Remarks
25652
Cabinet
Temperature
Unacceptable
Settheupperlimitofthecabinet
temperaturealarmTUTHD5C
lowerthantheambient
temperatureorsetthelowerlimit
ofTLTHD5Chigherthanthe
ambienttemperature,andwait
morethan10s.
Settheprecedingparameters
onlywhenthePMU,TCU,orFMU
isconfigured.Selectthe
configurationobjectoftheboard
towhichthesensorisconnected.
Thisalarmisreportedonly
whenthetemperaturesensoris
configuredbydefaultoris
installedinthecabinet.
Thetemperaturesensorisnot
configuredbydefaultinthe
BTS3900,BTS3900L,or
BTS3900Ccabinet.
Thetemperaturesensoris
configuredbydefaultinthe
BTS3900A(withRFC),
DBS3900(withRFC),and
BTS3900ALcabinets.
25672
BurglarAlarm
Openthecabinetdoorandwait
morethan10s.
Thisalarmisreportedonly
whenthedoorstatussensoris
configuredbydefaultoris
installedinthecabinet.
Thedoorstatussensorisnot
configuredbydefaultinthe
BTS3900,BTS3900L,DBS3900
(withOMBorIMB),or
BTS3900Ccabinet.
Thedoorstatussensoris
configuredbydefaultinthe
BTS3900A,DBS3900(with
APM30HorTMC),and
BTS3900ALcabinets.
25654
Battery
Temperature
Unacceptable
Inahightemperaturescenario:
Settheupperlimitofthebattery
temperaturealarmTUTHDlower
thantheambienttemperatureor
settheambienttemperature
higherthantheupperlimit,and
waitmorethan2s.
Inalowtemperaturescenario:Set
thelowerlimitofthebattery
temperaturealarmTLTHDhigher
thantheambienttemperatureor
settheambienttemperaturelower
thanthelowerlimit,andwaitmore
than2s.
Settheprecedingparameters
onlywhenthebatteryis
configured.Fordetails,seePower
ManagementFeatureParameter
Description.
Thisalarmisreportedonly
whenthebatteryisconfigured
inthecabinet.
25650
Ambient
Temperature
Unacceptable
Inahightemperaturescenario:
Settheupperlimitoftheambient
temperaturealarmTUTHDlower
thantheambienttemperatureor
settheambienttemperature
higherthantheupperlimit,and
waitmorethan2s.
Inalowtemperaturescenario:Set
thelowerlimitoftheambient
temperaturealarmTLTHDhigher
Thisalarmisreportedonly
whentheEMUorEMUAis
configured.
thantheambienttemperatureor
settheambienttemperaturelower
thanthelowerlimit,andwaitmore
than2s.
Settheprecedingparameters
onlywhentheEMUisconfigured.
25651
Ambient
Humidity
Unacceptable
Inahighhumidityscenario:Set
theupperlimitoftheambient
humidityalarmHUTHDlowerthan
theambienthumidityorsetthe
ambienthumidityhigherthanthe
upperlimit,andwaitmorethan
2s.
Inalowhumidityscenario:Setthe
lowerlimitoftheambienthumidity
alarmHLTHDhigherthanthe
ambienthumidityorsetthe
ambienthumiditylowerthanthe
lowerlimit,andwaitmorethan2s.
Settheprecedingparameters
onlywhentheEMUisconfigured.
25653
Cabinet
Humidity
Unacceptable
Settheupperlimitofthecabinet
humidityalarmHUTHD10%RH
lowerthanthecabinethumidityor
setthelowerlimitofHLTHD10%
RHhigherthanthecabinet
humidity,andwaitmorethan10s.
Settheprecedingparameters
onlywhentheEMUisconfigured.
25670
WaterAlarm
Performanyofthefollowing
operations:
Placethewatersensorinwater
formorethan10s.
Disconnectthewatersensor.
25671
SmokeAlarm
Performanyofthefollowing
operations:
Generatesmokearoundthe
smokesensorformorethan
15s.
Disconnectthesmokesensor
andsetthesmokesensoralarm
tohighvoltage.
Step3IfacustomizedBooleanalarmdeviceisconnected,checkwhetheranalarmisreportedbysettingthealarmdevicetohighlevel
orlowlevel.Verifythatthealarmsarecorrectlyconfigured.
End
4.4.9Reconfiguration
Whenyoureconfigureparametersformonitoringdevices,collectinformationaboutparameterstobereconfiguredbasedononsite
hardwareconfigurationandenvironmentmonitoringrequirements.Fordetails,seesection4.4.3"DataPreparation."
RuntheMODPMUcommandtoreconfigurePMUparameters.
RuntheMODFMUcommandtoreconfigureFMUparameters.
RuntheMODTCUcommandtoreconfigureTCUparameters.
RuntheMODCCUcommandtoreconfigureCCUparameters.
RuntheMODEMUcommandtoreconfigureEMUparameters.
4.4.10Deactivation
N/A
4.5Optimization
N/A
4.6Troubleshooting
Table427listscommonalarmsrelatedtomonitoringdevicefaultsandTable426listscommonalarmsrelatedtoenvironment
exceptions.Fordetailsabouthowtoclearthesealarms,seeNodeBAlarmReferenceandeNodeBAlarmReference.
Table427Commonalarmsrelatedtomonitoringdevicefaults
AlarmID
AlarmName
ALM25600
MonitoringDeviceMaintenanceLinkFailure
ALM25601
MonitoringDeviceHardwareFault
ALM25602
SensorFailure
ALM25620
MonitoringDevicePowerSupplyProblem
5EngineeringGuidelines(GSM)
5.1WhentoUseMonitoringManagement
ItisrecommendedthatthemonitoringmanagementfeaturebeenabledwhenyouintendtomonitorpowerandfanunitsinaBTS.If
auxiliarydevicescapableofmonitoringfunctionsareconfiguredforaBTS,itisrecommendedthatthecustomizedalarmfunctionbe
enabled.
5.2InformationtoBeCollected
Softwareconfigurationvariesaccordingtohardwareconfigurationandcableconnectionsbetweenmonitoringboards.Beforeyou
configuresoftware,collectinformationaboutthefollowingdevicesbasedonthehardwareconfigurationorhardwareconfigurationplan:
Plannedorinstalledboardsrelatedtomonitoring
Table41liststheboardsthatneedtobeconfiguredfordifferenttypesofBTSsindifferentscenarios.IftheGATMboardisconfigured
foraBTS,theboardmustalsobeconfiguredforotherscenarioslistedinTable41.ThelogicalnameofGATMisGATM.Thelogical
namesinTable41arethenamesofdevicesdisplayedontheconfigurationtoolinterface.
Devicesthatmanageboards
BoardmanagersincludeBBU,CCU,andRRU.Collecttheirrespectiveinformationaccordingtothehardwareconnectionsonsite.
ThelogicalnamesinTable41arethenamesofdevicesdisplayedontheconfigurationtoolinterface.
5.3NetworkPlanning
RFPlanning
N/A
NetworkTopology
N/A
HardwarePlanning
TheEMUorEMUAmayberequiredforconfiguringcustomizedalarmsonBTSs.Table42describesthehardwareplanningfor
customizedalarmconfiguration.ThehardwareplanningforvariousBTSstypesisthesameasthatforNodeBsandeNodeBs.
5.4FeatureDeployment
5.4.1DeploymentProcedure
Thereisnofixedsequenceforconfiguringthemonitoringmanagementfeature.
5.4.2DeploymentRequirements
None
5.4.3DataPreparation
GenericData
None
ScenariospecificData
Thefollowingscenarioscanbeusedtogether.Iftheyareusedtogether,dataforallthesescenariosmustbeprepared.
Scenario1:ConfiguringthePMU
FortheparametersettingsforthePMU,seePowerManagementFeatureParameterDescription.
Scenario2:ConfiguringtheFMU
Table51describestheparametersettingsfortheFMU.
Table51ParametersettingsfortheFMU
Parameter
Name
ParameterID
SettingDescription
Thisparameterspecifiesthenumberofthe
Source
CabinetNo.
CN
cabinethousingtheFMU.
IfthenumberoftheRFChousingtheFMUis1,
setthisparameterto1.
Network
plan
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberofthe
subrackhousingtheFMU.
SubrackNo.
SRN
SlotNo.
SN
Setthisparameterto11or12.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberoftheslot
housingtheFMU.
Setthisparametertothedefaultvalue0.
BoardType
Board
Parameter
Configuration
Enabled
BT
CFGFLAG
SetthisparametertoFMU.
ThisparameterspecifieswhetherFMU
configurationisallowed.
SetthisparametertoYes.
Network
plan
Network
plan
Network
plan
Network
plan
Thisparameterspecifieswhethertoenable
smarttemperaturecontrol.
WhenthisparameterissettoENABLED,the
FMUadjuststhefanspeedaccordingtothe
temperaturecontrolparametersdeliveredby
theBBU.Inthismode,thefannoiseislow.
WhenthisparameterissettoDISABLED,the
FMUautomaticallyadjustsfanspeed
accordingtotheambienttemperature.Inthis
mode,thefannoiseishigh.
ThisparametercanbesettoENABLEDor
DISABLED.
Smart
Temperature
Control
STC
Network
plan
ENABLEDisrecommended.
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
Special
Boolean
AlarmFlag
Special
AlarmValid
Level
Configuration
Manager
CabinetNo.
Manager
SubrackNo.
SBAF
Valuerange:SMDISABLE(Smog{LowLevel}),
WIDISABLE(WaterImmersed{LowLevel}),
GMDISABLE(GateMagnetism{LowLevel}),
ARRESTER1(LightningArrester1{LowLevel}),
and
ARRESTER2(LightningArrester2{LowLevel})
ItisrecommendedthattheFMUnotbe
connectedtoexternalsensorsandallsensors
bedisabled.Ifyouwanttousethesensors,
contactHuaweitechnicalsupport.
Retainthedefaultsettings,whichmeanthatall
sensorsaredisabled.
Thisparameterspecifiesthelevelspecifications
forthededicatedBooleanalarm.Therearetwo
specifications:highlevelandlowlevelalarms.
SPECIALSWITCHERLEVEL
MCN
MSRN
ItisrecommendedthatthededicatedBoolean
alarmfunctionbedisabledontheFMU.When
SBAFisdisabled,thisparameterdoesnot
needtobeconfigured.
Thisparameterspecifiesthecabinetnumberof
theTMU,CCU,orRXU.TMU,CCU,andRXU
arethelogicalnamesoftheGTMU,CCU,and
RRUrespectively.
Duringsiteconfiguration,theFMUisnot
directlyconnectedtotheRXU.Setthis
parametertothecabinetnumberoftheTMUor
CCUthatconnectstotheFMU.
Thisparameterspecifiesthesubracknumberof
theTMU,CCU,orRXU.TMU,CCU,andRXU
arethelogicalnamesoftheGTMU,CCU,and
RRUrespectively.
Duringsiteconfiguration,theFMUisnot
Network
plan
Network
plan
Network
plan
Network
plan
directlyconnectedtotheRXU.Setthis
parametertothesubracknumberoftheTMU
orCCUthatconnectstotheFMU.
Thisparameterspecifiesthenumberofthe
serialportonthemanagertowhichtheFMUis
connected.
Manager
PortNo.
IftheFMUisconnectedtotheBBU:
UPEU/UEIU(MON1):1
MPN
Network
plan
UPEU/UEIU(MON0):0
IftheFMUisconnectedtotheCCU,itmustbe
connectedtoportD_COM1.Setthisparameterto
1.
Thisparameterspecifiesthecommunication
addressoftheFMU.AmaximumoftwoFMUs
canbeconfiguredonanRS485bus.
Address
ADDR
Setthisparameterasfollows:
UpperlevelFMUintwocascadedFMUs:14
Network
plan
LowerlevelFMUintwocascadedFMUs:15
ThisparameterspecifiestheFMUAboardtype.
FMUBoard
Type
SetthisparametertoOUTDOORwhenthe
FMUAisinstalledinanoutdoorcabinet.
FMUTYPE
SetthisparametertoINDOORwhenthe
FMUAisinstalledinanindoorcabinet.
Network
plan
Temperature
Control
Mode
Thisparameterspecifieswhichmodeisusedto
adjustthefanspeed.SetthisparametertoDefault.
TCMODE
Thedefaultmodeachievesatradeoffamong
powerconsumption,noise,andtemperature
control.Itappliestomostscenarios.
Network
Plan
Scenario3:ConfiguringtheTCU
Table52describestheparametersettingsfortheTCU.Parametersthatarenotlistedinthetabledonotneedtobeconfiguredforthe
3900seriesbasestations.
Table52ParametersettingsfortheTCU
ParameterName
ParameterID
SettingDescription
Source
Thisparameterspecifiesthenumberof
thecabinethousingtheTCU.
CabinetNo.
CN
IfthenumberoftheRFChousingthe
TCUis1,setthisparameterto1.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.
Network
plan
Thisparameterspecifiesthenumberof
thesubrackhousingtheTCU.
SubrackNo.
SRN
Setthisparameterto8or14.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.
Network
plan
Thisparameterspecifiesthenumberof
theslothousingtheTCU.
IftheTCUisinstalledintheBTS3900AL
AC,BTS3900ALDC,IBBS700D,or
IBBS700Tcabinet,setthisparameteras
follows:
SettheslotnumberoftheCMUFto0.
SettheslotnumberofHAU0to1.
SettheslotnumberofHAU1to2.
SlotNo.
SN
IftheTCUisinstalledintheTP48600A
cabinet,setthisparameterasfollows:
SettheslotnumberoftheCMUFfor
cabinettemperaturecontrolto0.
SettheslotnumberoftheCMUFfor
batterycabinettemperaturecontrolto
1.
SettheslotnumberofHAU0to2.
Network
plan
SettheslotnumberofHAU1to3.
IftheTCUisinstalledonothercabinet,
setthisparameterto0.
BoardType
BT
BoardParameter
Configuration
Enabled
CFGFLAG
Temperature
AlarmUpper
Threshold
Temperature
AlarmLower
Threshold
SetthisparametertoTCU.
ThisparameterspecifieswhetherTCU
configurationisallowed.
SetthisparametertoYes.
TUTHD
Thisparameterspecifiestheupper
temperaturelimitforthecabinet.Ifthe
temperatureexceedstheupperlimit,the
alarmALM25652CabinetTemperature
Unacceptableisreported.
Network
plan
Network
plan
Network
plan
Itisrecommendedthatthisparameter
besetto50fortheTCUintheBBCand
68fortheTCUinothercabinets.
TLTHD
Thisparameterspecifiesthelower
temperaturelimitforthecabinet.Ifthe
temperatureexceedsthelowerlimit,the
alarmALM25652CabinetTemperature
Unacceptableisreported.
Network
plan
Thedefaultvalueisrecommendedfor
thisparameter.
ManagerCabinet
No.
ManagerSubrack
No.
MCN
Thisparameterspecifiesthecabinet
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.
Network
plan
MSRN
Thisparameterspecifiesthesubrack
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.
Network
plan
Thisparameterspecifiesthenumberof
theserialportonthemanagertowhich
theTCUisconnected.
IftheTCUisconnectedtotheBBU:
UPEU/UEIU(MON1):1
UPEU/UEIU(MON0):0
ManagerPortNo.
MPN
IftheTCUisconnectedtotheCCU:
CMUFispermanentlyconnectedto
Network
plan
portD_COM0,setthisparameterto0
FAU0andFAU1arepermanently
connectedtoportD_COM3,setthis
parameterto3
IftheTCUisconnectedtotheRRU,
setthisparameterto0.
IntheAPM30HorTMC11Hcabinet,a
maximumoftwoTCUscanbe
configuredonanRS485bus.
Setthisparameterasfollows:
UpperlevelTCUintwocascaded
TCUs:7
LowerlevelTCUintwocascaded
TCUs:6
IntheIBBS200D/IBBS200Tcabinet,a
maximumoffourTCUscanbe
configuredonanRS485bus.
Setthisparameterasfollows:
IftheupperlevelTCUismanagedby
thePMUwhosecommunication
addressis3,setthisparameterto23.
IfthelowerlevelTCUismanagedby
thisPMU,setthisparameterto24.
Address
ADDR
IftheupperlevelTCUismanagedby
thePMUwhosecommunication
addressis4,setthisparameterto25.
IfthelowerlevelTCUismanagedby
thisPMU,setthisparameterto26.
Network
plan
IftheHAUsareinstalled,amaximumof
twoTCUscanbeconfiguredonan
RS485bus.
Setthisparameterasfollows:
UpperlevelTCUintwocascaded
TCUs:28
LowerlevelTCUintwocascaded
TCUs:29
AlarmParameter
Configuration
Enabled
Thisparameterspecifieswhetherto
enableSBAF.
ALMPARACFGFLAG
Itisrecommendedthatthisparameter
besettoNo,whichmeansthatSBAFis
disabled.
Network
plan
Thisparameterspecifieswhetherto
reportadedicatedBooleanalarm.Ifthe
shieldflagforaBooleanalarmis
selected,theBooleanalarmcannotbe
reported.
SpecialBoolean
AlarmFlag
Valuerange:WS_DISABLE(Water
ImmersedSensorDisabled)and
SS_DISABLE(SmogSensorDisabled).
ItisrecommendedthattheTCUnotbe
connectedtoexternalsensorsandall
sensorsbedisabled.Ifyouwanttouse
thesensors,contactHuaweitechnical
support.
SBAF
Network
plan
Retainthedefaultsettings,whichmean
thatallsensorsaredisabled.
Scenario4:ConfiguringtheCCU
Table53describestheparametersettingsfortheCCU.
Table53ParametersettingsfortheCCU
ParameterName
ParameterID
SettingDescription
Source
Thisparameterspecifiesthenumberofthe
cabinethousingtheCCU.
CabinetNo.
CN
SubrackNo.
SRN
IfthenumberoftheBTS3900ALcabinet
housingtheCCUis0,setthisparameterto
0.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberofthe
subrackhousingtheCCU.
Setthisparametertothedefaultvalue15.
SlotNo.
SN
Thisparameterspecifiesthenumberofthe
slothousingtheCCU.
Setthisparametertothedefaultvalue0.
BoardType
BT
BoardParameter
Configuration
Enabled
CFGFLAG
ManagerCabinet
No.
SetthisparametertoCCU.
ThisparameterspecifieswhetherCCU
configurationisallowed.
SetthisparametertoYes.
MCN
Thisparameterspecifiesthecabinetnumber
oftheTMU,CCU,orRXU.TMU,CCU,and
RXUarethelogicalnamesoftheGTMU,
CCU,andRRUrespectively.
Network
plan
Network
plan
Network
plan
Network
plan
Network
plan
Network
plan
TheCCUcanonlybemanagedbytheTMU.
ManagerSubrack
No.
MSRN
Thisparameterspecifiesthesubracknumber
oftheTMU,CCU,orRXU.TMU,CCU,and
RXUarethelogicalnamesoftheGTMU,
CCU,andRRUrespectively.
Network
plan
TheCCUcanonlybemanagedbytheTMU.
Thisparameterspecifiesthenumberofthe
serialportonthemanagertowhichtheCCU
isconnected.
ManagerPortNo.
MPN
Network
TheCCUmustbeconnectedtoportMON0
ontheBBU.Therefore,thisparametermust
besetto0.
ThisparameterspecifieswhethertheCCU
isdirectlyconnectedtoitsmanager.Ifthe
CCUisdirectlyconnectedtoitsmanager,
setthisparametertoYES.
plan
DirectConnectFlag
DCF
IftheCCUisconnectedtoitsmanagerover
acascadingCCU,setthisparameterto
NO.
Network
plan
Thisparameterspecifiestheinserted
positionoftheCCUonaCCUcascadedlink.
CascadeNo.
Connected
Standard
CCN
CS
Setthisparameterto1fortheleftmostCCU
onthelink(theCCUwhoseportFE_Lisnot
connected).Setthisparametertoaninteger
inascendingorderfortheotherCCUsonthe
link.
Thisparameterspecifiesthenetwork
technologytypeoftheBBUthatisdirectly
connectedtotheCCU.Setthisparameterto
GSM,UMTS,orLTE.
Network
plan
Network
plan
TheparameterisvalidonlywhentheDCFis
settoYes.
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfor
aBooleanalarmisselected,theBoolean
alarmcannotbereported.
SpecialBoolean
AlarmFlag
SBAF
Valuerange:WS_DISABLE(Water
ImmersedSensorDisabled)and
SS_DISABLE(SmogSensorDisabled).
ItisrecommendedthattheCCUnotbe
connectedtoexternalsensorsandall
sensorsbedisabled.Ifyouwanttousethe
sensors,contactHuaweitechnicalsupport.
Network
plan
Retainthedefaultsettings,whichmeanthat
thewatersensorandsmokesensorare
disabled.
Scenario5:ConfiguringtheGATM
Table54describestheparametersettingsfortheGATM.
Table54ParametersettingsfortheGATM
ParameterName
ParameterID
SettingDescription
Source
Thisparameterspecifiesthenumberof
thecabinethousingtheGATM.
CabinetNo.
CN
IfthenumberoftheAPM30Hhousingthe
GATMis1,setthisparameterto1.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.
SubrackNo.
SRN
SlotNo.
SN
Thisparameterspecifiesthenumberof
thesubrackhousingtheGATM.Itcanbe
setto40or59.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.
Thisparameterspecifiesthenumberof
theslothousingtheGATM.
Setthisparametertothedefaultvalue0.
BoardType
BT
BoardParameter
Configuration
Enabled
CFGFLAG
SetthisparametertoGATM.
ThisparameterspecifieswhetherGATM
configurationisallowed.
SetthisparametertoYes.
Thisparameterspecifieswhetherto
providepowersuppliestotowermounted
amplifiers(TMAs)ofbranches0through
Network
plan
Network
plan
Network
plan
Network
plan
Network
plan
ANT0ALDPower
Switch~ANT5ALD
PowerSwitch
AMPC0~AMPC5
5.
IfabranchisconnectedtoaTMA,set
thisparametertoON.
Network
plan
IfabranchisnotconnectedtoaTMA,
setthisparametertoOFF.
Thisparameterspecifiesthemodefor
reportingthefeedingcurrentalarmsof
TMAsofbranches0through5.Whenthe
feedingcurrentexceedsthethreshold,an
alarmisreported.
Valuerange:MODE1,MODE2,and
MODE3
MODE1:Onlymajoralarmsare
reported.
MODE2:Warningsandmajoralarms
arereported.Inthismode,both
warningsandmajoralarmsare
reportedasfixedvaluecurrent.
ANT0Alarm
Mode~ANT5
AlarmMode
MODE0~MODE5
Network
plan
MODE3:Warningsandmajoralarms
arereported.Inthismode,warnings
arereportedasperiodicpulsecurrent,
andmajoralarmsarereportedasfixed
valuecurrent.Periodicpulsecurrentis
reportedwhenthealarmreporting
requirementismetwithinapreset
period.Comparedwithfixedvalue
current,periodicpulsecurrentiseasily
reported.
Itisrecommendedthatthisparameterbe
settoMODE1.
ANT0ALDOver
CriticalAlarm
Threshold(mA)~
ANT5ALDOver
CriticalAlarm
Threshold(mA)
MAJORALMUP0~
MAJORALMUP5
Thisparameterspecifiesthethresholdfor
reportingthecriticalalarmrelatedtothe
feedingcurrentoftheTMA.
WhenthefeedingcurrentoftheTMA
onsiteexceedsthisthreshold,thealarm
ALM28002GATMALDCurrentOutof
Rangeisreported.
Network
plan
MINORALMUP0~
MINORALMUP5
Thisparameterspecifiesthethresholdfor
reportingthewarningrelatedtothe
feedingcurrentoftheTMA.Whenthe
feedingcurrentoftheTMAonsite
exceedsthisthreshold,thealarmALM
28002GATMALDCurrentOutofRange
isreported.
Network
plan
ANT0ALDLow
CurrentAlarm
Threshold(mA)~
ANT5ALDLow
CurrentAlarm
Threshold(mA)
ALMD0~ALMD5
Thisparameterspecifiesthethresholdfor
reportingthewarningrelatedtothe
feedingcurrentoftheTMA.Whenthe
feedingcurrentoftheTMAonsite
exceedsthisthreshold,thealarmALM
28002GATMALDCurrentOutofRange
isreported.
Network
plan
ManagerCabinet
No.
MCN
Thisparameterspecifiesthecabinet
numberoftheTMU,CCU,orRXU.TMU,
CCU,andRXUarethelogicalnamesof
theGTMU,CCU,andRRUrespectively.
Network
plan
MSRN
Thisparameterspecifiesthesubrack
numberoftheTMU,CCU,orRXU.TMU,
CCU,andRXUarethelogicalnamesof
theGTMU,CCU,andRRUrespectively.
Network
plan
ANT0ALDOver
WarningAlarm
Threshold(mA)~
ANT5ALDOver
WarningAlarm
Threshold(mA)
ManagerSubrack
No.
Thisparameterspecifiesthenumberof
theserialportonthemanagertowhich
theGATMisconnected.
Setthisparameterasfollows:
ManagerPortNo.
MPN
IftheGATMisconnectedtotheBBU:
GATM0isconnectedtoMON0onthe
UPEU.Setthisparameterto0.
GATM1isconnectedtoMON1onthe
UPEU.Setthisparameterto1.
IftheGATMisconnectedtoCCU:
GATM0ispermanentlyconnectedto
portD_COM5.Setthisparameterto5.
Network
plan
GATM1ispermanentlyconnectedto
portD_COM6.Setthisparameterto6.
Address
ADDR
Thisparameterspecifiesthe
communicationaddressoftheGATM.
Setthisparameterto22.
Network
plan
Scenario6:ConfiguringCustomizedAlarms
Topreparedataforcustomizedalarmconfiguration,performthefollowingsteps:
Step1PrepareEMUconfigurationdata.
Beforedatapreparation,checkwhethertheEMUneedstobeconfiguredbyreferringtoTable42.IftheEMUisrequired,
prepareEMUconfigurationdatabyreferringtoTable55.Otherwise,skipthisstep.
Step2Prepareconfigurationdataofthealarmsignalinputandoutputportsbasedontheinputandoutputrequirementsofcustomized
alarms.
PrepareconfigurationdataoftheenvironmentalalarmsignalinputportALMPORTbyreferringtoTable56.
PrepareconfigurationdataoftheenvironmentalalarmsignaloutputportOUTPORTbyreferringtoTable57.
End
Table55ParametersettingsfortheEMU
Parameter
Name
ParameterID
SettingDescription
Thisparameterspecifiesthenumber
ofthecabinethousingtheEMU.
CabinetNo.
SubrackNo.
CN
SRN
SlotNo.
SN
BoardType
BT
Board
Parameter
Configuration
Enabled
CFGFLAG
IfthenumberoftheBTS3900
cabinethousingtheEMUis0,set
thisparameterto0.
Thisparameterspecifiesthenumber
ofthesubrackhousingtheEMU.
Setthisparametertothedefault
value.
Thisparameterspecifiesthenumber
oftheslothousingtheEMU.
Setthisparametertothedefault
value.
SetthisparametertoEMU.
Thisparameterspecifieswhether
EMUconfigurationisallowed.
SetthisparametertoYes.
Source
Network
plan
Network
plan
Network
plan
Network
plan
Network
plan
Thisparameterspecifieswhetherto
reportadedicatedBooleanalarm.If
theshieldflagforaBooleanalarmis
selected,theBooleanalarmcannot
bereported.
SpecialAnalog
AlarmFlag
SAAF
Valuerange:48V_DISABLE(48
VoltageDisabled),
RES0(PreservedParameter0),
RES1(PreservedParameter1),
RES2(PreservedParameter2),
TS_DISABLE(TemperatureSensor
Disabled),HS_DISABLE(Humidity
SensorDisabled),RES3(Preserved
Parameter3),andRES4(Preserved
Parameter4)
Setthisparameterasfollows:
The48Valarmisusedtocheck
whethertheinputvoltageforthe
cabinetisnormal.Whentheinput
voltageforthecabinetis48V,itis
recommendedthat48V_DISABLE
becleared.
RES0,RES1,andRES2are
parametersreservedbyHuawei
andtheyareselected.
Setthesensorsaccordingtothe
typesofsensorsconnectedtothe
Network
plan
EMUorEMUA.
SpecialBoolean
AlarmFlag
SBAF
Thisparameterspecifieswhetherto
reportadedicatedBooleanalarm.If
theshieldflagforaBooleanalarmis
selected,theBooleanalarmcannot
bereported.
Valuerange:WILOW(Water
Immersed{LowLevel}),
SMLOW(Smog{LowLevel}),
IMLOW(Infrared{LowLevel}),and
GMLOW(GateMagnetism{Low
Level})
Network
plan
Setthisparameteraccordingtothe
typeofthesensororexternaldevice
connectedtotheEMU.
SpecialAlarm
SwitchValid
Vol.Level
Manager
CabinetNo.
Manager
SubrackNo.
SPECIALSWITCHERLEVEL
Thisparameterspecifiesthelevel
specificationsforthededicated
Booleanalarm.Therearetwo
specifications:HighLevelandLow
Level.
Network
plan
Setthisparameteraccordingtothe
typeofthesensororexternaldevice
connectedtotheEMU.
MCN
Thisparameterspecifiesthecabinet
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.
Network
plan
MSRN
Thisparameterspecifiesthesubrack
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.
Network
plan
Thisparameterspecifiesthenumber
oftheserialportonthemanagerto
whichtheEMUisconnected.Setthis
parameterasfollows:
IftheTCUisconnectedtotheBBU:
ManagerPort
No.
MPN
UPEU/UEIU(MON1):1
UPEU/UEIU(MON0):0
IftheTCUisconnectedtotheCCU,
itmustbeconnectedtoport
D_COM3.Setthisparameterto3.
Network
plan
IftheTCUisconnectedtotheRRU,
setthisparameterto0.
Address
ADDR
Thisparameterspecifiesthe
communicationaddressoftheEMU.
Setthisparameterto2.
HumidityAlarm
Lower
Threshold
HumidityAlarm
Upper
Threshold
TLTHD
Thisparameterspecifiesthelower
ambienttemperaturelimit.Ifthe
ambienttemperatureexceedsthe
lowerlimit,theBTSreportsthealarm
ALM25650AmbientTemperature
Unacceptable.
Thisparameterneedstobe
configuredonlywhenTS_DISABLE
inSAAFiscleared.
Thedefaultvalueisrecommended
forthisparameter.
TUTHD
Thisparameterspecifiestheupper
ambienttemperaturelimit.Ifthe
ambienttemperatureexceedsthe
upperlimit,theNodeBoreNodeB
reportsthealarmALM25650
AmbientTemperatureUnacceptable.
Thisparameterneedstobe
configuredonlywhenTS_DISABLE
inSAAFiscleared.
Thedefaultvalueisrecommended
forthisparameter.
Thisparameterspecifiesthelower
Network
plan
Network
plan
Network
plan
Temperature
AlarmLower
Threshold
ambienthumiditylimit.Iftheambient
humidityexceedsthelowerlimit,the
alarmALM25651AmbientHumidity
Unacceptableisreported.
Thisparameterneedstobe
configuredonlywhenHS_DISABLE
inSAAFiscleared.
HLTHD
Network
plan
Thedefaultvalueisrecommended
forthisparameter.
Temperature
AlarmUpper
Threshold
Thisparameterspecifiestheupper
ambienthumiditylimit.Iftheambient
humidityexceedstheupperlimit,the
alarmALM25651AmbientHumidity
Unacceptableisreported.
Thisparameterneedstobe
configuredonlywhenHS_DISABLE
inSAAFiscleared.
HUTHD
Network
plan
Thedefaultvalueisrecommended
forthisparameter.
Table56ParametersettingsfortheALMPORT
ParameterName
ParameterID
SettingDescription
Source
CabinetNo.
CN
Thisparameterspecifiesthecabinetnumber
oftheboardwheretheALMPORTportis
located.
Network
plan
SubrackNo.
SRN
Thisparameterspecifiesthesubracknumber
oftheboardwheretheALMPORTportis
located.
Network
plan
SlotNo.
SN
Thisparameterspecifiestheslotnumberof
theboardwheretheALMPORTportis
located.
Network
plan
Thisparameterspecifiesthenumbersofthe
alarmportsoneachmonitoringboardas
follows:
PortNo.
PN
UPEU/UEIU:0to7(forBooleanalarms)
RRU:0to3(forBooleanalarms)
Network
plan
EMU/EMUA:0to31(forBooleanalarms)
EMU/EMUA:32to35(foranalogalarms)
Ifacustomizedalarminputisrequired,the
switchmustbeturnedon.Thisparameter
specifiestheswitchoftheportandcanbeset
asfollows:
OFF(Off):indicatesthattheportisdisabled
andalarmscannotbedetected.Thisisthe
defaultvalueforthisparameter.
ON(On):indicatesthattheportisenabled
andalarmscanbereportedthroughthe
portaccordingtothecustomizedalarmIDs.
Inaddition,thealarmvoltagelevelfor
Booleanalarmsorthealarmupper/lower
limitcanbesetinthisparameter.
Switch
AlarmID.
SW
AID
ThisparameterspecifiesthealarmID
pertainingtothealarmport.Ifanalarmis
detectedthroughtheport,thevalueofthis
parameterisusedasthealarmIDandis
reportedwiththealarm.Thevaluerangeof
thisparameteris65033to65233.
Network
plan
Network
plan
Thealarmname,alarmseverity,andOSS
typecorrespondingtothealarmIDare
configuredontheM2000client.
Thisparameterspecifiesthetypeofanalarm
port.SetthisparametertoBOOLorVALUE.
PortType
PT
Ananalogport,providedbytheEMUor
EMUA,monitorstheexternalenvironment.
Adigitalport,providedbytheUPEU,UEIU,
RRU,EMU,orEMUA,monitorstheexternal
environmentwithBooleanordiscretevalues.
ThisparameterisvalidonlywhenPTissetto
Network
plan
AlarmVOL.
AVOL
BOOL.
Thisparameterspecifieswhetherthesensor
sendstheportahighlevelorlowlevelalarm.
Setthisparameterbasedonalarmcable
connection.Fordetailsaboutthepin
assignmentforthewiresofalarmcables,see:
Section"BBUAlarmCable"inthebase
Network
plan
stationspecifichardwaredescription.
Section"RRUAlarmCable"intheRRU
specifichardwaredescription.
Section"RS485SerialPort"inEMUUser
GuideandEMUAUserGuide.
Thisparameterspecifiesthealarmupper
limit.Iftheenvironmentmeasurementvalueis
greaterthanthealarmupperlimitofthe
sensor,thealarmisreported.
UpperLimit
UL
Environmentmeasurementvalue=
Measurementlowerlimit+(Measurement
upperlimitMeasurementlowerlimit)x
(ObservedcurrentorvoltageOutputlower
limit)/(OutputupperlimitOutputlowerlimit).
Network
plan
ULmustbesmallerthanorequaltoSMUL
andgreaterthanLL.
Thisparameterspecifiesthealarmlowerlimit.
Iftheenvironmentmeasurementvalueis
smallerthanthealarmlowerlimitofthe
sensor,thealarmisreported.
LowerLimit
LL
Environmentmeasurementvalue=
Measurementlowerlimit+(Measurement
upperlimitMeasurementlowerlimit)x
(ObservedcurrentorvoltageOutputlower
limit)/(OutputupperlimitOutputlowerlimit).
Network
plan
LLmustbegreaterthanorequaltoSMLL
andsmallerthanUL.
SensorType
ST
Thisparameterspecifiesthetypeofasensor.
SetthisparametertoVOLTAGEor
CURRENTbasedontheexternalsensor
specifications.
Network
plan
ThisparameterisvalidonlywhenPTissetto
VALUE.
MeasureUpper
LimitOfSensor
SMUL
Thisparameterspecifiesthemeasurement
upperlimitoftheanalogport.Setthis
parameterbasedonthesiteconditions,such
asthetemperatureandhumidity.
SMULmustbegreaterthanorequaltoUL.
Network
plan
SMULmustbegreaterthanSMLL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
MeasureLower
LimitOfSensor
SMLL
Thisparameterspecifiesthemeasurement
lowerlimitoftheanalogport.Setthis
parameterbasedonthesiteconditions,such
asthetemperatureandhumidity.
SMLLmustbesmallerthanorequaltoLL.
Network
plan
SMLLmustbesmallerthanSMUL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
UpperLimitOf
SensorOutput
SOUL
Thisparameterspecifiestheoutputsignal
upperlimitoftheanalogport.Forasensorof
eitherthecurrenttypeorthevoltagetype,set
thisparameterbasedontheexternalsensor
specifications.
Network
plan
SOULmustbegreaterthanSOLL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
LowerLimitOf
SensorOutput
SOLL
Thisparameterspecifiestheoutputsignal
lowerlimitoftheanalogport.Forasensorof
eitherthecurrenttypeorthevoltagetype,set
thisparameterbasedontheexternalsensor
specifications.
SOLLmustbesmallerthanSOUL.
Network
plan
Table57ParametersettingsfortheOUTPORT
Parameter
Name
ParameterID
Refrigeration
Equipment
COLDSET
SettingDescription
Thisparameterspecifieswhethertoenable
arefrigerationdeviceontheBTS.
Setthisparametertochannel0outputof
theEMU.
Heating
Equipment
WARMSET
Thisparameterspecifieswhethertoenable
aheatingdeviceontheBTS.
Setthisparametertochannel1outputof
theEMU.
Dehumidification
Equipment
DRYSET
Thisparameterspecifieswhethertoenable
adehumidifierontheBTS.
Setthisparametertochannel2outputof
theEMU.
Humidification
Equipment
WETSET
Thisparameterspecifieswhethertoenable
ahumidifierontheBTS.
Setthisparametertochannel3outputof
theEMU.
Fire
extinguishing
Equipment
FIRESET
Antitheft
Equipment
DESTEALSET
Thisparameterspecifieswhethertoenable
afireextinguishingdeviceontheBTS.
Setthisparametertochannel4outputof
theEMU.
Thisparameterspecifieswhethertoenable
anantitheftdeviceontheBTS.
Setthisparametertochannel5outputof
theEMU.
Source
Network
plan
Network
plan
Network
plan
Network
plan
Network
plan
Network
plan
ReferenceforConfiguringtheMonitoringFunction
See"ReferenceforConfiguringtheMonitoringFunction"insection4.4.3"DataPreparation."
5.4.4Precautions
N/A
5.4.5HardwareInstallation
Fordetailsabouthardwareinstallation,seesection"InstallingMonitoringSignalCable"inthebasestationspecificinstallationguide.
WhensettingexternalBooleanalarmsbasedonthehighorlowvoltagesettings,seethefollowingsectionstoobtainthepinassignment
forthewiresofalarmcables:
Section"BBUAlarmCable"inthebasestationspecifichardwaredescription.
Section"RRUAlarmCable"intheRRUspecifichardwaredescription.
Section"RS485SerialPort"inEMUUserGuideandEMUAUserGuide.
5.4.6FeatureActivation/InitialConfiguration
Thescenariosforconfiguringmonitoringmanagementcanbeusedtogether.Iftheyareusedtogether,dataforallthesescenarios
mustbeconfigured.Thereisnofixedsequenceforconfiguringthemonitoringmanagementfeature.WhentheEMUorEMUAis
installedforconfiguringcustomizedalarms,configuretheEMU,andthentheALMPORTorOUTPORT.
ConfiguringaSingleBTSontheGUI
ToconfigurethemonitoringfunctionforaBTS,seesection"CreatingaGBTS(TopologyMode,3900SeriesBaseStations)>
ConfiguringGBTSDeviceData(3900SeriesBaseStations)>ConfiguringMonitoringBoards"in3900SeriesBaseStationInitial
Configuration(SRAN7.0)>GBTSInitialConfiguration.
Whenyounavigateinthedocument,locatethecorrectnodebasedonthetypeofthebasestationcontrollerconnectedtothebase
station.
ConfiguringBTSsinBatches
ToconfigurethemonitoringfunctionforBTSsinbatches,customizeatemplatebasedonaconfiguredBTSandthenconfigureBTSsin
batchesbasedonthetemplate.
Fordetails,seesection"CreatingGBTSs(byUsingaSummaryDataFile)"inInitialConfigurationof3900SeriesBaseStations>GBTS
InitialConfiguration.
Whenyounavigateinthedocument,locatethecorrectnodebasedonthetypeofthebasestationcontrollerconnectedtothebase
station.
ConfiguringaSingleBTSUsingMMLCommands
Scenario1:ConfiguringthePMU
FordetailsabouthowtoconfigurethePMU,seePowerManagementFeatureParameterDescription.
Scenario2:ConfiguringtheFMU
Step1RuntheADDBTSBRDcommandtoaddanFMU.
Step2RuntheSETBTSFMUABPcommandtosetFMUparameters.
End
Scenario3:ConfiguringtheTCU
Step1RuntheADDBTSBRDcommandtoaddaTCU.
Step2RuntheSETBTSDHEUBPcommandtosetTCUparameters.
End
Scenario4:ConfiguringtheCCU
Step1RuntheADDBTSBRDcommandtoaddaCCU.
Step2RuntheSETBTSCCUBPcommandtosetCCUparameters.
End
Scenario5:ConfiguringtheGATM
Step1RuntheADDBTSBRDcommandtoaddaGATM.
Step2RuntheSETBTSDATUBPcommandtosetGATMparameters.
End
Scenario6:ConfiguringCustomizedAlarms
Step1(Optional)ConfiguredevicesandparametersrelatedtotheEMU.
1.RuntheADDBTSBRDcommandtoaddanEMU.
2.RuntheSETBTSDEMUBPcommandtosetEMUparameters.
3.IftheEMUisconnectedtoahumidityortemperaturesensor,runtheSETBTSEXDcommandtosetEMUextensionparameters.
Step2RuntheLSTBTSENVALMPORTandLSTBTSOUTPUTcommandstoquerythestatusoftheinputandoutputalarmports,
respectively.
Step3Basedonthequeryresults,runthefollowingcommandstoopentheportthatneedstobeconfiguredasaninputalarmport
andclosetheunusedalarmport.
SETBTSENVALMPORT:tosettheinputalarmport
SETBTSOUTPUT:tosettheoutputalarmport
Step4Addandbindacustomizedalarm,andchangethealarmseverity.
AcustomizedalarmconfiguredontheBTSmustbeaddedandboundtotheM2000sothatthealarmconsolecanidentifyandreport
thealarm.
1.LogintotheM2000client.
2.ChooseMonitor>AlarmSetting>NEAlarmSetting.TheNEAlarmSettingwindowisdisplayed.
3.ChooseUserDefinedAlarm>AlarmDefinition.TheAlarmDefinitiontabpageisdisplayed.
Fordetails,seesection"FaultManagement>FaultMonitoring>DefininganNEAlarm"intheM2000documentation.
Ifyouconfiguretheoutputalarmport,youdonotneedtobindthealarmtotheM2000.
End
5.4.7Commissioning
N/A
5.4.8ActivationVerification
Toverifythemonitoringfunction,performthefollowingsteps:
Step1RuntheDSPBTSBRDcommandtocheckwhetherboardsareworkingproperly.
Ifthesystemreturnsanycommandoutputforaboard,theboardisworkingproperly.Whenalltheboardsareworkingproperly,
proceedtoStep2.
Step2PerformtheoperationsdescribedinTable426andcheckwhetherambientalarmsarecorrectlyreported.Ifalarmscannotbe
reported,checkhardwareconnectionsandsoftwareconfigurations.
Step3IfacustomizedBooleanalarmdeviceisconnected,checkwhetheranalarmisreportedbysettingthealarmdevicetohighlevel
orlowlevel.Verifythatthealarmsarecorrectlyconfigured.
End
5.4.9Reconfiguration
Whenyoureconfigureparametersformonitoringdevices,collectinformationaboutparameterstobereconfiguredbasedononsite
hardwareconfigurationandenvironmentmonitoringrequirements.Fordetails,seesection5.4.3"DataPreparation."
ThecommandsforreconfiguringGBTSmonitoringdevicesarethesameasinitialconfigurationcommands.Fordetails,seesection
5.4.6"FeatureActivation/InitialConfiguration."
5.4.10Deactivation
N/A
5.5Optimization
N/A
5.6Troubleshooting
ThealarmsforBTSsarethesameasthoseforNodeBsandeNodeBs.Fordetails,seeTable427.Fordetailsaboutenvironment
alarms,seeTable426.Ifanalarmisreported,clearthealarmwithrecommendedactionsinalarmreferenceoftheBSC.
6EngineeringGuidelines(DualModes)
ItisrecommendedthattheonesidedconfigurationmodebeappliedtothefollowingtypesofMBTSs:
BTS3900
BTS3900L
BTS3900A
DBS3900(withouttheTP48600A)
TheonesidedconfigurationmodemustapplytothefollowingtypesofMBTSs:
BTS3900AL
DBS3900(withtheTP48600A)
SRAN6.0andlaterversionssupportonesidedconfiguration.VersionsearlierthanSRAN6.0supportonlymodebymodeconfiguration.
IftheprecedingMBTSsareconfiguredmodebymode,thealarmALM26271InterSystemMonitoringDeviceParameterSettings
Conflictisreportedevenwhentheconfigurationonbothmodesisconsistent.
ThefollowingsectionsprovidetheprecautionsforconfiguringMBTSsindifferentmodes.
6.1PrecautionsforOneSidedConfiguration
Thissectiondescribestheconfigurationprecautionsinonesidedconfigurationmode.Forthemethodofdeployingthisfeatureinone
sidedconfigurationmode,seechapter4"EngineeringGuidelines(UMTSorLTE)"andchapter5"EngineeringGuidelines(GSM)."
ThemonitoringdevicesofthesamebasestationmustbeconfiguredforthesameRAT.
Foradualmodebasestation,themonitoringdevicesareconfiguredaccordingtothefollowingpriorityorder:GSM,UMTS,LTE.
Forexample,assumethataBTS3900Ahasthefollowingconfiguration:2APM30Hs+2RFCs+2IBBS200DsorIBBS200Ts,andthe
BTS3900AisusedintheUO+LOscenario.Inthisexample,themonitoringdevicesoftheBTS3900AareconfiguredforUMTS.
Foratriplemodebasestation,themonitoringdevicesareconfiguredaccordingtothemonitoringcableconnectionsinthecabinet.If
themonitoringcablesareconnectedtothedualmodeBBU,configurethemonitoringdevicesaccordingtothefollowingpriorityorder:
GSM,UMTS,LTE.
Forexample,asshowninFigure61,theBTS3900Ahasthefollowingconfiguration:2APM30Hs+2RFCs+2IBBS200Dsor
IBBS200Ts,andtheBTS3900AisusedintheGO+UO+LOscenario.APM30H0housesGUdevices(includingBBUandRFU),and
APM30H1housesLTEdevices.ThemonitoringdevicesandcascadingmonitoringdevicesofAPM30H1areconnectedtoAPM30H
0.TheBBUinAPM30H0performsmonitoringmanagement.Inthisexample,themonitoringdevicesoftheBTS3900Aareconfigured
forGSM.
Figure612APM30Hs+2RFCs+2IBBS200DsorIBBS200Ts
Intheexpansionorevolutionscenario,itisrecommendedthattheRATbeforetheexpansionorevolutionbeconfigured.Then,you
donotneedtoreconstructinventorydevices.Ifthepreviousconditioncannotbemet,configurethemonitoringdevicesaccordingto
thefollowingpriorityorder:GSM,UMTS,LTE.Then,reconstructinventorydevices.
Forexample,ifaGBTS(BTS3900)hasevolvedintoaGUdualmodebasestation,configurethemonitoringdevicesoftheevolved
basestationforGSM.
Intheremotemonitoringscenario,configurethemonitoringdevicesofthesinglemodeRRUfortheRAToftheRRU.Itis
recommendedthatyouconfigurethemonitoringdevicesofthedualmodeRRUaccordingtothefollowingpriorityorder:GSM,
UMTS,LTE.
6.2PrecautionsforModebyModeConfiguration
Thissectiondescribestheconfigurationprecautionsformodebymodeconfiguration.Thereisnofixedsequenceformodebymode
configuration.Fordetails,seechapter4"EngineeringGuidelines(UMTSorLTE)"andchapter5"EngineeringGuidelines(GSM)."
ThemonitoringdevicesconnectedtoBBUsmustbemonitoredbybasestationsusingdifferentRATs.Therefore,whenyouconfigure
thesemonitoringdevices,ensurethatthenumberofphysicaldevicesandconfigurationparametersareconsistentforbasestations
usingdifferentRATs.Fordetailsabouttheparametersthatmustbekeptconsistentoneachmode,seeTable61.
Table61Parametersthatmustbekeptconsistentoneachmode
Object
FMU
TCU
GSMParameter
UMTSandLTEParameters
SettingDescription
Parameter
Name
Parameter
ID
Configuration
Command
Parameter
Name
Parameter
ID
Configuration
Command
Special
Boolean
AlarmFlag
SBAF
SETBTSFMUABP
Special
Boolean
AlarmFlag
SBAF
ADDFMU
Thedefaultvalueis
recommended:
WS_DISABLE(Water
ImmersedSensor
Disabled)and
SS_DISABLE(Smog
SensorDisabled)
Smart
Temperature
Control
STC
SETBTSFMUABP
Smart
Temperature
Control
STC
ADDFMU
ENABLED
SETBTSDHEUBP
Temperature
AlarmLower
Threshold
ADDTCU
Thedefaultvalueis
recommended.
ADDTCU
Temperature
AlarmLower
Threshold
TLTHD
TLTHD
SETBTSDHEUBP
Temperature
AlarmUpper
Threshold
Temperature
AlarmUpper
Threshold
TUTHD
TUTHD
SETBTSDHEUBP
Special
Boolean
AlarmFlag
Special
Boolean
AlarmFlag
SBAF
CCU
Special
Boolean
AlarmFlag
SBAF
Special
Boolean
AlarmFlag
Setthisparameter
to68fortheTCUin
othercabinets.
ADDTCU
Thedefaultvalueis
recommended:
WS_DISABLE(Water
ImmersedSensor
Disabled)and
SS_DISABLE(Smog
SensorDisabled)
ADDCCU
Thedefaultvalueis
recommended:
WS_DISABLE(Water
ImmersedSensor
Disabled)and
SS_DISABLE(Smog
SensorDisabled)
SBAF
SETBTSCCUBP
SBAF
Setthisparameter
to50fortheTCUin
theBBC.
EMU
Temperature
AlarmLower
Threshold
TLTHD
Temperature
AlarmUpper
Threshold
TUTHD
Humidity
AlarmLower
Threshold
HLTHD
Humidity
AlarmUpper
Threshold
HUTHD
SETBTSEXD
Temperature
AlarmLower
Threshold
SETBTSEXD
Temperature
AlarmUpper
Threshold
TUTHD
Humidity
AlarmLower
Threshold
HLTHD
Humidity
AlarmUpper
Threshold
HUTHD
SETBTSEXD
SETBTSEXD
TLTHD
ADDEMU
Thedefaultvalueis
recommended.
ADDEMU
Thedefaultvalueis
recommended.
ADDEMU
Thedefaultvalueis
recommended.
ADDEMU
Thedefaultvalueis
recommended.
SETBTSDEMUBP
Itisrecommended
that48V_DISABLE
becleared.
SetRES0and
RES1,andselect
RES2.
SetTS_DISABLE
andHS_DISABLE
basedonthetypes
ofsensors
connectedtothe
EMUorEMUA.
Special
AnalogAlarm
Flag
Special
AnalogAlarm
Flag
SAAF
SAAF
ADDEMU
SETBTSDEMUBP
Special
Boolean
AlarmFlag
Special
Boolean
AlarmFlag
SBAF
SBAF
ADDEMU
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
PN
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonalarm
cableconnection.
Ifacustomizedalarm
needstobe
configured,setthe
parametertoON.If
else,settoOFF.
ALMPORT
PN
SET
BTSENVALMPORT
Switch
SW
SET
BTSENVALMPORT
Switch
SW
SET
ALMPORT
AlarmID.
AID
SET
BTSENVALMPORT
AlarmID.
AID
SET
ALMPORT
Setthevalueinthe
rangeof65033~
65233.
SET
ALMPORT
Itisrecommended
thatthisparameterbe
settoVALUEor
BOOLbasedon
customizedalarm
type.
SET
ALMPORT
Itisrecommended
thatthisparameterbe
settohighlevelor
lowlevelbasedon
alarmcable
connection.
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
PortNo.
PortType
Alarm
Voltage
AlarmUpper
Limit
AlarmLower
Limit
SensorType
PT
AVOL
UL
LL
ST
SET
BTSENVALMPORT
SET
BTSENVALMPORT
SET
BTSENVALMPORT
SET
BTSENVALMPORT
SET
BTSENVALMPORT
PortNo.
PortType
Alarm
Voltage
AlarmUpper
Limit
AlarmLower
Limit
SensorType
PT
AVOL
UL
LL
ST
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
Sensor
Measurement
UpperLimit
Sensor
Measurement
LowerLimit
Sensor
OutputUpper
Limit
Sensor
OutputLower
Limit
SMUL
SMLL
SOUL
SOLL
SET
BTSENVALMPORT
SET
BTSENVALMPORT
Sensor
Measurement
UpperLimit
Sensor
Measurement
LowerLimit
SET
BTSENVALMPORT
Sensor
OutputUpper
Limit
SET
BTSENVALMPORT
Sensor
OutputLower
Limit
SMUL
SMLL
SOUL
SOLL
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
SET
ALMPORT
Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.
Thealarmparametersrelatedtotheexternalenvironment,suchaswaterandsmokesensorparametersmustbeconfigured
consistentlyforbothmodes.
Ifanyinconsistencyisdetected,thebasestationsofbothmodeswillreportthealarmALM26271InterSystemMonitoringDevice
ParameterSettingsConflict.
Toavoidinconsistency,youcanperformanMBTSconsistencycheckafterconfiguringparameters.Toperformaconsistencycheckon
theCMEclient,chooseMBTSApplication>MBTSCheckConsistencyfromthemenubarofacurrentorplanneddataarea.To
performaconsistencycheckontheM2000client,chooseCMExpress>MBTSApplication>MBTSCheckConsistency.For
detailedoperations,seesection"CheckingMBTSDataConsistency"inCMEConfigurationManagement.
7ReferenceDocuments
Thischapterliststhereferencedocumentsrelatedtomonitoringmanagement:
[1]PowerManagementFeatureParameterDescription
[2]BaseStationCabinetsandSubracks(IncludingtheBBUSubrack)Configuration
[3]BTS3900(Ver.B)HardwareDescription
[4]BTS3900(Ver.C)HardwareDescription
[5]BTS3900(Ver.D)HardwareDescription
[6]BTS3900L(Ver.B)HardwareDescription
[7]BTS3900L(Ver.C)HardwareDescription
[8]BTS3900L(Ver.D)HardwareDescription
[9]BTS3900A(Ver.B)HardwareDescription
[10]BTS3900A(Ver.C)HardwareDescription
[11]BTS3900A(Ver.D)HardwareDescription
[12]BTS3900AL(Ver.A)HardwareDescription
[13]DBS3900HardwareDescription
[14]BTS3900CWCDMAHardwareDescription
[15]BTS3900C(Ver.C)HardwareDescription
[16]RRUspecifichardwaredescription
[17]TP48600AH17B1UserManual
[18]IBBS700D&IBBS700TUserManual
[19]InitialConfigurationof3900SeriesBaseStations
[20]eNodeBInitialConfigurationGuide
[21]EMUUserGuide
[22]EMUAUserGuide