SingleRAN

MonitoringManagement
FeatureParameterDescription

CopyrightHuaweiTechnologiesCo.,Ltd.2012.Allrightsreserved.
NopartofthisdocumentmaybereproducedortransmittedinanyformorbyanymeanswithoutpriorwrittenconsentofHuawei
TechnologiesCo.,Ltd.

TrademarksandPermissions
andotherHuaweitrademarksarethepropertyofHuaweiTechnologiesCo.,Ltd.Allothertrademarksandtradenames
mentionedinthisdocumentarethepropertyoftheirrespectiveholders.

Notice
Thepurchasedproducts,servicesandfeaturesarestipulatedbythecommercialcontractmadebetweenHuaweiandthecustomer.All
orpartialproducts,servicesandfeaturesdescribedinthisdocumentmaynotbewithinthepurchasedscopeortheusagescope.
Unlessotherwiseagreedbythecontract,allstatements,information,andrecommendationsinthisdocumentareprovided"ASIS"
withoutwarranties,guaranteesorrepresentationsofanykind,eitherexpressorimplied.
Theinformationinthisdocumentissubjecttochangewithoutnotice.Everyefforthasbeenmadeinthepreparationofthisdocumentto
ensureaccuracyofthecontents,butallstatements,information,andrecommendationsinthisdocumentdonotconstituteawarrantyof
anykind,expressorimplied.

Contents
1Introduction
1.1Scope
1.2IntendedAudience
1.3ChangeHistory

2OverviewofMonitoringManagement
2.1MonitoringManagers
2.1.1BBUMonitoringPorts
2.1.2CCUMonitoringPorts
2.1.3RRUMonitoringPorts
2.2MonitoringPrinciples
2.2.1Singlemode/DualmodeBaseStation
2.2.2TriplemodeBaseStation
2.3CustomizedAlarms

3EngineeringGuidelines
4EngineeringGuidelines(UMTSorLTE)
4.1WhentoUseMonitoringManagement
4.2InformationtoBeCollected
4.3NetworkPlanning
4.4FeatureDeployment
4.4.1DeploymentProcedure
4.4.2DeploymentRequirements
4.4.3DataPreparation
4.4.4Precautions
4.4.5HardwareInstallation
4.4.6FeatureActivation/InitialConfiguration
4.4.7Commissioning
4.4.8ActivationVerification
4.4.9Reconfiguration
4.4.10Deactivation
4.5Optimization
4.6Troubleshooting

5EngineeringGuidelines(GSM)
5.1WhentoUseMonitoringManagement
5.2InformationtoBeCollected
5.3NetworkPlanning
5.4FeatureDeployment
5.4.1DeploymentProcedure
5.4.2DeploymentRequirements
5.4.3DataPreparation
5.4.4Precautions
5.4.5HardwareInstallation
5.4.6FeatureActivation/InitialConfiguration
5.4.7Commissioning
5.4.8ActivationVerification
5.4.9Reconfiguration
5.4.10Deactivation
5.5Optimization
5.6Troubleshooting

6EngineeringGuidelines(DualModes)
6.1PrecautionsforOneSidedConfiguration
6.2PrecautionsforModebyModeConfiguration

7ReferenceDocuments

1Introduction
1.1Scope

Thisdocumentdescribestheprinciplesandengineeringguidelinesforthe3900seriesbasestationmonitoringmanagementfeature.
The3900seriesbasestationmonitoringmanagementfeatureinvolvestwobasicLTEfeatures,LBFD004012EnvironmentMonitoring
andTDLBFD004012EnvironmentMonitoring.InGBSS,RAN,andSRAN,the3900seriesbasestationmonitoringmanagementisa
basicfeatureandinvolvesnofeatureID.
Thisdocumentisapplicabletothefollowing3900seriesbasestations:
BTS3900(Ver.B),BTS3900(Ver.C),andBTS3900(Ver.D)
BTS3900L(Ver.B),BTS3900L(Ver.C),andBTS3900L(Ver.D)
BTS3900A(Ver.B),BTS3900A(Ver.C),andBTS3900A(Ver.D)
BTS3900AL(Ver.A)
DBS3900
BTS3900C,BTS3900C(Ver.B),andBTS3900C(Ver.C)

Anymanagedobjects(MOs),parameters,alarms,orcountersdescribedinthisdocumentcorrespondtothesoftwarereleasedelivered
withthisdocument.Intheeventofupdates,theupdateswillbedescribedintheproductdocumentationdeliveredwiththelatest
softwarerelease.

1.2IntendedAudience
Thisdocumentisintendedfor:
Personnelwhoneedtounderstandmonitoringmanagement
Fieldengineers

1.3ChangeHistory
Thissectionprovidesinformationaboutthechangesindifferentdocumentversions.
Therearetwotypesofchanges,whicharedefinedasfollows:
Featurechange:referstoachangeinthemonitoringmanagementfeatureofaspecificproductversion.
Editorialchange:referstoachangeinwordingortheadditionofinformationthatwasnotdescribedintheearlierversion.

DocumentIssues
Thedocumentissuesareasfollows:
03(20120915)
02(20120723)
01(20120425)
DraftB(20120310)
DraftA(20120110)

03(20120915)
Thisisthethirdcommercialrelease.
Comparedwithissue02(20120723),thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type

ChangeDescription

ParameterChange

Feature
change

Addedthefollowinginformation:
MonitoringprinciplesoftheBTS3900(Ver.D)
in"BTS3900"insection2.2.1"Single
mode/DualmodeBaseStation."

None

MonitoringprinciplesoftheBTS3900L
(Ver.D)in"BTS3900L"insection2.2.1
"Singlemode/DualmodeBaseStation."

MonitoringprinciplesoftheBTS3900A
(Ver.D)in"BTS3900A"insection2.2.1
"Singlemode/DualmodeBaseStation."
MonitoringprinciplesoftheDBS3900housed
intheAPM30H(Ver.D)orTMC11H(Ver.D)
in"DBS3900"insection2.2.1"Single
mode/DualmodeBaseStation."

Editorial
change

None

None

02(20120723)
Thisisthesecondofficialrelease.
Comparedwithissue01(20120425),thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type

ChangeDescription

ParameterChange

Feature
change

Addedthelownoisemodeforthefan.

AddedtheTCMODEparameter
fortheFMUinGSM,UMTS,and
LTEmodes.

Editorial
change

None

None

01(20120425)
Thisisthefirstofficialrelease.
ComparedwithdraftB(20120310),thisissuedoesnotincorporateanychange.

DraftB(20120310)
Thisisadraft.
ComparedwithdraftA(20120110),thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type

ChangeDescription

ParameterChange

Feature
change

TheparametervalueGS_DISABLE(Door
SensorDisabled)ofSBAFinCCUisdeleted.

None

Editorial
change

Addedchapter3"EngineeringGuidelines."

None

Optimizedtheprecautionsofchapter6
"EngineeringGuidelines(DualModes)."

None

DraftA(20120110)
Thisisadraft.
ThisdocumentisthefirstreleaseforSRAN7.0,GBSS14.0,andRAN14.0.
ForeRAN3.0,thisdocumentismodifiedbasedonissue03(20111224)ofeRAN2.2.Comparedwithissue03(20111224)of
eRAN2.2,thisissueincorporatesthechangesdescribedinthefollowingtable.
Change
Type

ChangeDescription

ParameterChange

Feature
change

AddedthefollowingBTS3900ALrelated
information:
MonitoringprinciplesoftheBTS3900ALin
section2.2.1"Singlemode/DualmodeBase
Station."

AddedtheCCUMO.
AddedthefollowingCCUrelated
parameters:

CCUinformationinsection2.1.2"CCU

MonitoringPorts."

Editorial
change

DCF
CCN
CS

Addedthemonitoringprinciplesofthe
DBS3900housedintheTP48600Acabinetin
section2.2.1"Singlemode/DualmodeBase
Station."

None

Addedthemonitoringprinciplesand
engineeringguidelinesfortheNodeB,BTS,
andMBTS.

AddedGSMandUMTS
configurationparameters.

Addedsection2.2"MonitoringPrinciples."

None

Addedthereferenceforconfiguringthe
monitoringfunctioninsection4.4.3"Data
Preparation."

None

2OverviewofMonitoringManagement
Themonitoringsystemisanimportantcomponentofabasestation.Thesystemmonitorsthepowersupply,fans,andenvironmentin
thecabinet.Whenafaultisdetected,thesystemreportsanalarm.Inaddition,themonitoringsystemcollectsalarmsignalsfrom
outsidethecabinettomonitortheenvironmentandspecifieddevices,suchasdieselgeneratorsandequipmentroomdoorstatus
controldevices.

2.1MonitoringManagers
Themonitoringmanagersincludethebasebandunit(BBU),cabinetcontrolunit(CCU),andradioremoteunit(RRU).Themonitored
devicesinthecabinetcommunicatewiththemonitoringmanagersthroughanRS485bus.
TheBBUisthemonitoringmanagementcenterformostbasestations.Bothinternalandexternalalarmsaredirectlyreportedtothe

BBUandthenforwardedtothealarmconsole.
Whenabasestationhasmanydevicestobemonitoredinthecabinets,theBBUmonitoringportscannotmeetthemonitoring
requirements.Inthissituation,theCCUofeachcabinetmonitorsdeviceshousedinthecabinet.TheCCUsarecascadedandoneCCU
reportsalarmstotheBBU.Currently,onlytheBTS3900ALcabinet,TP48600AH17B1(TP48600Aforshort)cabinetforDBS3900,and
IBBS700D/IBBS700TcabinetusetheCCUstoimplementmonitoringmanagement.
ForsomeDBS3900s,alarmsaremanagedbytheRRUbecausetheRRUisinstalledfarawayfromtheBBU.TheRRUreportsalarms
totheBBUthroughacommonpublicradiointerface(CPRI)fiberopticcableandtheBBUthenforwardsthealarmstothealarm
console.Thisscenarioiscalledremotemonitoring.

2.1.1BBUMonitoringPorts
InaBBU,theuniversalpowerandenvironmentinterfaceunit(UPEU)anduniversalenvironmentinterfaceunit(UEIU)boardsprovide
monitoringports.EachboardprovidestwoBooleaninputportsandtwoRS485inputports.EachBooleaninputportsupportsfour
Booleaninputs.
WhenaBBUisconfiguredwithoneUPEU,theBBUprovideseightBooleaninputsandtwoRS485inputs.
WhenaBBUisconfiguredwithtwoUPEUsorwithoneUPEUandoneUEIU,theBBUprovides16BooleaninputsandfourRS485

inputs.ThetwoMON0portsondifferentUPEUsorontheUPEUandUEIUareinterconnectedthroughRS485bus0,andthetwo
MON1portsareinterconnectedthroughRS485bus1.
Figure21showsthemonitoringportsontheUPEUandUEIU.
Figure21MonitoringportsontheUPEUandUEIU

Table21describesthemonitoringportsontheUPEUandUEIU.
Table21MonitoringportsontheUPEUandUEIU
Board

Label

Connector

Description

UPEU

EXTALM0

RJ45

ForBooleaninputs0to3

EXTALM1

RJ45

ForBooleaninputs4to7

MON0

RJ45

RS485inputport0

MON1

RJ45

RS485inputport1

EXTALM0

RJ45

ForBooleaninputs0to3

EXTALM1

RJ45

ForBooleaninputs4to7

MON0

RJ45

RS485inputport0

MON1

RJ45

RS485inputport1

UEIU

2.1.2CCUMonitoringPorts
TheCCUmonitorstheenvironmentanddevicesinthecabinet.Figure22showsthemonitoringportsontheCCU.
Figure22CCUmonitoringports

Table22describesthemonitoringportsontheCCU.FordetailsaboutthefunctionsoftheotherportsontheCCU,seesection"CCU"
inBTS3900AL(Ver.A)HardwareDescription.
Table22CCUmonitoringports
Label

Connector

Description

FE_L,FE_R

RJ45

ForCCUcascading

D_COM0toD_COM7

RJ45

DownlinkRS485ports0to7for
communicatingwithboardsinthecabinet

U_COM0toU_COM2

RJ45

UplinkRS485ports0to2forcommunicating
withupperlevelboards

TEM

4pinwireterminalblock

Reservedforthetemperaturesensor

SMOKE

2pinwireterminalblock

Forthesmokesensorthatisoptionally
configured

GATE

2pinbarewireterminal
block

Forthedoorstatussensorthatisconfigured
bydefault

IN0

2pinbarewireterminal
block

ReservedfortwoBooleaninputs

IN1

2pinbarewireterminal
block

FortheACsurgeprotectorthatisconfigured
bydefault

LAMP

2pinbarewireterminal
block

Forthecabinetlampthatisconfiguredby
default

2.1.3RRUMonitoringPorts
RRUmonitoringportsvarywithRRUmodels.SomeRRUsprovideonemonitoringportwhichsupportstwoorfourBooleaninputsand
oneRS485input.SomeRRUsdonotprovideanymonitoringport.
Fordetails,seesection"RRUPorts"intheRRUspecifichardwaredescription.

2.2MonitoringPrinciples
2.2.1Singlemode/DualmodeBaseStation
Themonitoringboardsofabasestationreportmonitoringinformation.Forexample,thefanmonitoringunit(FMU)reportsfan
monitoringinformation,thepowermonitoringunit(PMU)reportspowersupplymonitoringinformation,andtheenvironmentmonitoring
unit(EMU)orenvironmentmonitoringunittypeA(EMUA)reportsenvironmentmonitoringalarmsandcustomizedalarms.Allthe
monitoringsignalsaretransmittedtotheBBU,CCU,orRRUmonitoringportsthroughanRS485bus.Thissectiondescribesthe
connectionsbetweenthemonitoringboardsandtheBBU,CCU,andRRU.

Fordetailsabouthowtoconnectthemonitoringsignalcablesoftheboardstorelevantports,seesections"MonitoringPrinciplesoftheCabinet"and
"MonitoringSignalCableConnections"inthebasestationspecifichardwaredescription.

BTS3900
Figure23showsthemonitoringprinciplesoftheBTS3900cabinet(AC).ThemonitoringprinciplesoftheBTS3900(Ver.B),BTS3900
(Ver.C),andBTS3900(Ver.D)cabinetsarethesame.TheFMU,PMU,andGSMantennaandTMAcontrolmodule(GATM)
communicatewiththeBBU'sMONportsthroughanRS485serialbus.TheGATMisaBTSspecificboardandisnotusedwiththe
NodeBoreNodeB.
Themonitoredboardsarecascadedinsequence.Ifalowerlevelboardisnotconfigured,themonitoringsignalcableisdirectly
connectedtoanupperlevelboard.Forexample,iftheGATMisnotconfigured,theFMUandPMUaredirectlyconnectedtotheBBU's
MONports.
Figure23MonitoringprinciplesoftheBTS3900(AC)

Cabinet0isthefirstcabinetofthistypeconfiguredatasite.Thesameruleappliestonumberingtheothercabinetsofthistype.

ThemonitoringprinciplesoftheBTS3900cabinet(48VDC)andthoseoftheBTS3900cabinet(+24VDC)aresimilar.Inboth
cabinets,thePMUisnotconfiguredandcanbeignoredinFigure23.Inaddition,theDC/DCpowersystemoftheBTS3900cabinet

(+24VDC)needstobeconnectedtotheBBU'sEXT_ALMporttoreportBooleansignals.

BTS3900L
Figure24showsthemonitoringprinciplesoftheBTS3900Lcabinet(48VDC).ThemonitoringprinciplesoftheBTS3900L(Ver.B),
BTS3900L(Ver.C),andBTS3900L(Ver.D)cabinetsarethesame.TheFMUandGATMcommunicatewiththeBBU'sMONports
throughanRS485serialbus.TheGATMisaBTSspecificboardandisnotusedwiththeNodeBoreNodeB.
Themonitoredboardsarecascadedinsequence.Ifalowerlevelboardisnotconfigured,themonitoringsignalcableisdirectly
connectedtoanupperlevelboard.Forexample,iftheGATMisnotconfigured,theFMUisdirectlyconnectedtotheBBU'sMONport.

InFigure24,FMU0referstotheFMUinthelowerlevelsubrackandFMU1referstotheFMUintheupperlevelsubrackinthe
BTS3900Lcabinet.CascadethemfollowingthesequenceshowninFigure24.
Figure24MonitoringprinciplesoftheBTS3900L

BTS3900A
Figure25andFigure26showthemonitoringprinciplesoftheBTS3900Acabinet(AC)andBTS3900Acabinet(DC),respectively.The
centralmonitoringunittypeA(CMUA)/centralmonitoringunittypeE(CMUE)/centralmonitoringunittypeEA(CMUEA),PMU,GATM,
andEMUcommunicatewiththeBBU'sMONportsthroughanRS485serialbus.TheGATMisaBTSspecificboardandisnotused
withtheNodeBoreNodeB.
Themonitoredboardsarecascadedinsequence.Ifanupperlevelboardisnotconfigured,themonitoringsignalcableisdirectly
connectedtoalowerlevelboard.Forexample,iftheTMCcabinetisnotconfigured,ignoretheconnectionsrelatedtoTMCcabinet
connectionsshowninFigure25andFigure26.TheCMUEincabinetRFC0isdirectlyconnectedtotheCMUEincabinetRFC1.
ThemonitoringprinciplesoftheBTS3900A(Ver.B)cabinetarethesameasthoseoftheBTS3900A(Ver.C)cabinet,exceptthatthe
CMUEisreplacedwiththeCMUA.
ThemonitoringprinciplesoftheBTS3900A(Ver.D)cabinetarethesameasthoseoftheBTS3900A(Ver.C)cabinet,exceptthatno
Hertpowermonitoringinterfaceunit(HPMI)isconfiguredandtheCMUEisreplacedwiththeCMUEA.TheHPMIdoesnotmonitor
signalsbuttransferssignalsforthePMU.Figure25andFigure26showthemonitoringprinciplesonlyfortheBTS3900A(Ver.C)
cabinet.

Twobatterybackupcabinets(BBCs)arecascadedinsequenceandcannotbeconnectedtothesamePMU.Forexample,ifBBC0
connectstothePMU'sCOM_485port,BBC1connectstotheCMUE'sCOM_OUTportinBBC0andcannotbeconnectedtotheother
RS485portsonthePMU.
Figure25MonitoringprinciplesoftheBTS3900A(AC)

TheBBCcabinetreferstoIBBS200DandIBBS200T(IBBSisshortforintegratedbackupbatterysystem).

Figure26MonitoringprinciplesoftheBTS3900A(48VDC)

DBS3900
TheDBS3900hasmultipleapplicationscenarios.TheDBS3900monitoringprinciplesvarywithhardwareconfigurations,asdescribed
inTable23.
Table23IndextableofDBS3900monitoringprinciples
InstallationScenario
(InputPower)

InstallationScenario(Cabinet
Configuration)

Description

110VAC/220VAC

APM30H(Ver.C),TMC11H(Ver.C),and
IBBS200D(Ver.C)/IBBS200T(Ver.C)

Themonitoringprinciplesarethe
sameasthoseoftheBTS3900A
cabinet(AC).SeeFigure25.

APM30H(Ver.B),TMC11H(Ver.B),and
IBBS200D(Ver.B)/IBBS200T(Ver.B)
APM30H(Ver.D),TMC11H(Ver.D),and
IBBS200D(Ver.D)/IBBS200T(Ver.D)

TheDBS3900isnotconfiguredwith
theGATMortheRFCcabinet,sothe
cableconnectionstotheGATMorto
theRFCcabinetcanbeignored.The
BBUintheAPM30Hcabinetis
directlyconnectedtotheCMUEin
theTMC11Hcabinet.

110VAC/220VAC

APM30H(Ver.B)/APM30H(Ver.C)/
APM30H(Ver.D),and
IBBS200D/IBBS200T,inRRUremote
monitoringmode

SeeFigure27.

110VAC/220VAC

TP48600A

SeeFigure28.

48VDC

TMC11H(Ver.B)

SeeinFigure29.

TMC11H(Ver.C)

APM30H(Ver.D)
+24VDC

APM30H(Ver.B)

See
inFigure29.

110VAC/220VAC

Outdoorminibox(OMB)

SeeinFigure29.

48VDC

OMB

SeeinFigure29.The
monitoringprinciplesaresimilar
tothoseoftheOMB(AC)except
thatthePMUisnotusedforthe
OMB(DC).

110VAC/220VAC

OMB(Ver.C)

SeeinFigure29.

48VDC

OMB(Ver.C)

SeeinFigure29.The
monitoringprinciplesaresimilar
tothoseoftheOMB(AC)except
thatthePMUisnotusedforthe
OMB(DC).

110VAC/220VAC

Indoorcentralizedrack(ICR):BBUand
PMUareinstalledintheupperandlower
racksrespectivelyintheindoorminibox
(IMB03)

See
inFigure29.

+24VDC

ICR:BBUisinstalledintheIMB03

See
inFigure29.

110VAC/220VAC

IMB03

See
inFigure29.

48VDC

IMB03

Monitoringisnotrequired.

FortheAPM/TMCseriescabinetsusedintheDBS3900inRRUremotemonitoringmode,themonitoringprinciplesoftheVer.B
cabinetsarethesameasthoseoftheVer.Ccabinets,exceptthattheCMUEisreplacedwiththeCMUA.Inaddition,themonitoring
principlesoftheVer.DcabinetsarethesameasthoseoftheVer.Ccabinets,exceptthattheCMUEisreplacedwiththeCMUEA.Figure
27showsthemonitoringprinciplesoftheVer.Ccabinets.
ThemonitoringprinciplesoftheOMB(Ver.C)cabinetarethesameasthoseoftheOMBcabinet,exceptthattheHEUAisreplacedwith
theHEUB.Figure29showsthemonitoringprinciplesoftheOMBcabinet.
Figure27Remotemonitoringprinciples

Figure28MonitoringprinciplesoftheDBS3900housedinTP48600A

Figure29MonitoringprinciplesoftheDBS3900housedinothercabinets

BTS3900AL
TheBTS3900ALusesCCUstomonitorboardsinitscabinets,asshowninFigure210.TheCMUF,FAU,andPMUcommunicatewith
theCCUs'downlinkRS485portsthroughanRS485serialbus.OneCCUthenreportsalarmstotheBBUthroughtheCCU'suplink
RS485port.TheGATMisaBTSspecificboardandisnotusedwiththeNodeBoreNodeB.
IftheTMCandIBBS700D/IBBS700Tcabinetsarenotconfigured,ignoretheboardsinthesecabinets.
Figure210MonitoringprinciplesoftheBTS3900ALinsinglemodeordualmode

BTS3900C
ThemonitoringprinciplesoftheBTS3900CarethesameasthoseoftheDBS3900housedintheOMB.Themonitoringprinciplesofthe
BTS3900C(Ver.C)arethesameasthoseoftheDBS3900housedintheOMB(Ver.C).Fordetails,seeTable23.

2.2.2TriplemodeBaseStation
TwoBBUsarerequiredforthebasestationevolutionfromsingleordualmodetotriplemodeorwhenatriplemodebasestationis
deployed.
AllthemonitoreddevicesoftheBTS3900,BTS3900L,BTS3900A,andDBS3900(nothousedinTP48600A)areconnectedonlyto

BBU0(hubBBU).TheextensionBBUdoesnotprovidemonitoringmanagement.
Figure211showsthemonitoringprinciplesoftheBTS3900ALwheretwoBBUsareconfigured.BBU0andBBU1areconnectedto

theCCU'suplinkRS485portsU_COM0andU_COM1,respectively.ThemonitoringprinciplesoftheDBS3900housedinTP48600A
aresimilar.
Figure211MonitoringprinciplesoftheBTS3900ALintriplemode

2.3CustomizedAlarms
Youcancustomizealarmstomonitorexternaldevices.
ToimplementBooleansignalinput,connectthemonitoreddevicestotheBBU,RRU,EMU,orEMUAthathasBooleanalarmsignal

inputports.
Toimplementanalogsignalinput,connectthemonitoreddevicestotheEMUorEMUAthathasanalogalarmsignalinputports.
ToimplementBooleansignaloutput,connectthemonitoreddevicestotheEMUorEMUAthathasBooleansignaloutputports.

Ambientalarmsarecommoncustomizedalarms.Theyaregeneratedaftersensorsinstalledoutdoorsorintheequipmentroomreceive
alarmsignals.Somebasestationshavesensorsthatarepreinstalledbeforedelivery,asshowninTable24.
Table24Sensorspreinstalledonbasestationsbeforedelivery
BaseStationType

Cabinet

PreinstalledSensor

BTS3900/BTS3900L

BTS3900/BTS3900L

None

BTS3900A/DBS3900 (1)

APM30H(Ver.B)/APM30H
(Ver.C)

Doorstatussensor,whichis
connectedtotheHPMI'sGATE
port.

APM30H(Ver.D)

Doorstatussensor,whichis
connectedtothePMU'sGATE
port.

RFC

Doorstatussensor,whichis

(2)

connectedtotheCMUA's(3),
CMUE's,orCMUEA'sGATE
port.
Temperaturesensor,whichis

connectedtotheCMUA's,
CMUE's,orCMUEA'sTEMport.
TMC11H

Doorstatussensor,whichis
connectedtotheCMUA's(4),
CMUE's,orCMUEA'sGATEport.

IBBS200D/IBBS200T

Doorstatussensor,whichis

connectedtotheCMUA's,
CMUE's,orCMUEA'sGATE
port.
Temperaturesensorforthe

battery,whichisconnectedto
theCMUA's,CMUE's,or
CMUEA'sTEM_BATport.
BTS3900AL(5)

BTS3900AL(AC)/BTS3900AL(DC)

Doorstatussensor,whichis

connectedtotheCCU'sGATE
port.
Returnairtemperaturesensorfor

HEXinnercirculation,whichis
connectedtotheCMUF'sTEM0
port.

Intakeairtemperaturesensorfor

theRFcompartment,whichis
connectedtotheFAU'sTEM0
port.
Supplyairtemperaturesensorfor
HEXinnercirculation,whichis
connectedtotheCMUF's
TEMP1port.

BTS3900C

TMC11H

Doorstatussensor,whichis
connectedtotheCMUA's,
CMUE's,orCMUEA'sGATEport.

BTS3900C

None

(1)TheDBS3900housedintheOMBorIMBdoesnothavepreinstalledsensors.
(2)TheDBS3900mayalsobeconfiguredwiththeTP48600Acabinet.Fordetailsaboutthesensorconfigurationinthiscabinet,seeTP48600AH17B1User
Manual.
(3)IntheBTS3900A(Ver.B),thesensorsareconnectedtotheCMUA.IntheBTS3900A(Ver.C),thesensorsareconnectedtotheCMUE.IntheBTS3900A
(Ver.D),thesensorsareconnectedtotheCMUEA.
(4)IntheTMC11H(Ver.B),thesensorsareconnectedtotheCMUA.IntheTMC11H(Ver.C),thesensorsareconnectedtotheCMUE.IntheTMC11H(Ver.D),
thesensorsareconnectedtotheCMUEA.
(5)TheBTS3900ALmayalsobeconfiguredwiththeTP48600AandIBBS700D/IBBS700Tcabinets.Fordetailsaboutthesensorconfigurationinthese
cabinets,seeTP48600AH17B1UserManualandIBBS700D&IBBS700TUserManual.

3EngineeringGuidelines
Inamultimodebasestation,deploytheMonitoringManagementfeatureeitherinsingleordualmodes.
Forthemethodofdeployingthisfeatureinsinglemode,seechapter4"EngineeringGuidelines(UMTSorLTE)"andchapter5

"EngineeringGuidelines(GSM)."
Forthemethodofdeployingthisfeatureindualmode,seechapter6"EngineeringGuidelines(DualModes)."

4EngineeringGuidelines(UMTSorLTE)
4.1WhentoUseMonitoringManagement
ItisrecommendedthatthemonitoringmanagementfeaturebeenabledwhenyouintendtomonitorpowerandfanunitsinaNodeBor
eNodeB.IfauxiliarydevicescapableofmonitoringfunctionsareconfiguredforaNodeBoreNodeB,itisrecommendedthatthe
customizedalarmfunctionbeenabled.

4.2InformationtoBeCollected
Softwareconfigurationvariesaccordingtohardwareconfigurationandcableconnectionsbetweenmonitoringboards.Beforeyou
configuresoftware,collectinformationaboutthefollowingdevicesbasedonthehardwareconfigurationorhardwareconfigurationplan:
Plannedorinstalledboardsrelatedtomonitoring

Table41liststheboardsthatneedtobeconfiguredfordifferenttypesofNodeBsandeNodeBsindifferentscenarios.
Devicesthatmanageboards

BoardmanagersincludeBBU,CCU,andRRU.Collecttheirrespectiveinformationaccordingtothehardwareconnectionsonsite.
ThelogicalnamesinTable41arethenamesofdevicesdisplayedontheconfigurationtoolinterface.
Table41BoardsrequiredfordifferenttypesofNodeBsandeNodeBsindifferentscenarios
NodeBandeNodeB
Type

UsageScenario

BTS3900(Ver.B)
BTS3900(Ver.C)
BTS3900(Ver.D)
BTS3900L(Ver.B)
BTS3900L(Ver.C)

Board

Logical
Name

48VDCpowerinput

FMU

FMU

+24VDCpowerinput

FMU

FMU

110VAC/220VACpowerinput

FMU

FMU

PMU

PMU

PMU

PMU

CMUA

TCU

CMUA

FMU

BTS3900L(Ver.D)
BTS3900A(Ver.B)

RequiredBoard

APM30H(Ver.B)cabinet

RFC(Ver.B)cabinet

BTS3900A(Ver.C)

BTS3900A(Ver.D)

DBS3900

TMC11H(Ver.B)cabinet

CMUA

TCU

IBBS200D(Ver.B)/IBBS200T(Ver.B)
cabinet

CMUA

TCU

APM30H(Ver.C)cabinet

PMU

PMU

CMUE

TCU

RFC(Ver.C)cabinet

CMUE

FMU

TMC11H(Ver.C)cabinet

CMUE

TCU

IBBS200D(Ver.C)/IBBS200T(Ver.C)
cabinet

CMUE

TCU

APM30H(Ver.D)cabinet

PMU11A

PMU

CMUEA

TCU

RFC(Ver.D)cabinet

CMUEA

FMU

TMC11H(Ver.D)cabinet

CMUEA

TCU

IBBS200D(Ver.D)/IBBS200T(Ver.D)
cabinet

CMUEA

TCU

APM30H(Ver.B)cabinet

PMU

PMU

CMUA

TCU

TMC11H(Ver.B)cabinet

CMUA

TCU

IBBS200D(Ver.B)/IBBS200T(Ver.B)
cabinet

CMUA

TCU

IBBS700DorIBBS700Tcabinet

CCU

CCU

CMUF

TCU

HAU

TCU

PMU

PMU

CMUA

TCU

TMC11H(Ver.C)cabinet

CMUE

TCU

IBBS200D(Ver.C)/IBBS200T(Ver.C)
cabinet

CMUE

TCU

APM30H(Ver.D)cabinet

PMU11A

PMU

CMUEA

TCU

TMC11H(Ver.D)cabinet

CMUEA

TCU

IBBS200D(Ver.D)/IBBS200T(Ver.D)
cabinet

CMUEA

TCU

OMBcabinet

HEUA

TCU

PMU

PMU

HEUB

TCU

PMU11A

PMU

IMBcabinet

PMU

PMU

IMBcabinet(inICRscenario)

PMU

PMU

TP48600Acabinet

CCU

CCU

PMU

PMU

CMUF

TCU

HAU

TCU

CCU

CCU

CMUF

TCU

PMU

PMU

FAU

FMU

HAU

TCU

CCU

CCU

CMUF

TCU

APM30H(Ver.C)cabinet

OMB(Ver.C)cabinet

BTS3900AL(Ver.A)

BTS3900AL(AC)cabinet

BTS3900AL(DC)cabinet

BTS3900C/BTS3900C
(Ver.B)

BTS3900C(Ver.C)

FAU

FMU

HAU

TCU

TMC11H(Ver.C)cabinet

CMUE

TCU

IBBS700DorIBBS700Tcabinet

CCU

CCU

CMUF

TCU

HAU

TCU

DCpowerinput

HEUA

TCU

ACpowerinput

PMU

PMU

HEUA

TCU

DCpowerinput

HEUB

TCU

ACpowerinput

PMU11A

PMU

HEUB

TCU

ThefullnamesoftheboardslistedinTable41areasfollows:
(1)FMU:fanmonitoringunit
(2)PMU:powermonitoringunit
(3)PMU11A:powermonitoringunit
(4)CMUA:centralmonitoringunittypeA
(5)TCU:temperaturecontrolunit
(6)CCU:cabinetcontrolunit
(7)HEUA:heatexchangeunittypeA
(8)HEUB:heatexchangeunittypeB
(9)CMUE:centralmonitoringunittypeE
(10)CMUF:centralmonitoringunittypeF
(11)CMUEA:centralmonitoringunittypeEA
(12)FAU:fanassemblyunit
(13)HAU:heaterassemblyunit
ThemonitoringboardsrequiredbytheTP48600AcabinetdonotneedtobeconfiguredwhenothercabinetsareconfiguredforaNodeBoreNodeB.

4.3NetworkPlanning
RFPlanning
N/A

NetworkTopology
N/A

HardwarePlanning
ConfigurationPlanningforMonitoringDevices
TheEMUorEMUAmayberequiredforconfiguringcustomizedalarmsonNodeBsandeNodeBs.Table42describesthehardware
planningforcustomizedalarmconfiguration.ThelogicalnamesinTable42arethenamesofdevicesdisplayedontheconfiguration
toolinterface.
Table42Hardwareplanningforcustomizedalarmconfiguration
NodeBand
eNodeBType

UsageScenario

BTS3900(Ver.B)
BTS3900(Ver.C)
BTS3900(Ver.D)

RequiredDevice
DeviceName

LogicalName

1to16Booleanalarminputs

NA(1)

NA

17to32Booleanalarminputs

EMU(2)

EMU

BTS3900L(Ver.B)

1to6Booleanalarmoutputs

EMU

EMU

BTS3900L(Ver.C)
BTS3900L(Ver.D)

RRUremotemonitoring

NA(3)

NA

1to4analogalarminputs

EMU

EMU

BTS3900A(Ver.B)

1to16Booleanalarminputs

NA(1)

NA

BTS3900A(Ver.C)
BTS3900A(Ver.D)

17to32Booleanalarminputs

EMUA(2)

EMU

DBS3900

1to4remoteBooleanalarminputs

NA(3)

NA

1to6Booleanalarmoutputs

EMUA

EMU

BTS3900AL(Ver.A)

BTS3900C(4)

1to4analogalarminputs

EMUA

EMU

1to16Booleanalarminputs

NA(1)

NA

BTS3900C(Ver.B)
(4)

BTS3900C(Ver.C)
(4)

(1)Whendefining1to16Booleaninputs,youcaninstalloneUPEUandoneUEIUinaBBU.Itisrecommendedthatyounotconfigurecustomizedalarmsof
theBooleanportsontheFMU,PMU,CMUA,CMUE,CMUF,orCCU.Ifyouwanttousethem,contactHuaweitechnicalsupport.
(2)TheEMUorEMUAsupports32Booleaninputsandfouranaloginputs.Fordetailsaboutthemonitoringportsonthem,seeEMUUserGuideandEMUA
UserGuide.
(3)SomeRRUssupportonlyoneBooleaninputandsomedonotsupportBooleaninputs.Fordetails,seesection"RRUPorts"intheRRUspecifichardware
description.
(4)TheEMUorEMUAcannotbeinstalledonBTS3900C,BTS3900C(Ver.B),orBTS3900C(Ver.C).

RequirementsforBooleanAlarmInputs
ConsiderthefollowingrequirementswhileplanningBooleanalarminputs:
Basestation'sBooleanalarminputsmustbedrycontactalarminputs.
ItisrecommendedthatopticalcouplingisolationorrelayisolationBooleaninputsbeused.Wheneitheroftheinputsisused,open

circuitindicatesalarmreporting,andshortcircuitindicatesnoalarm.
VoltagesignalsarenotusedasBBUBooleaninputs.Ifvoltagesignalalarmsareused,ensurethatalarmdevicesandalarminput

devices(BBU,EMU,orEMUA)areproperlygrounded.WhentheBBUinputalarmsareofthevoltagetype,0Vto0.7Vindicatelow
voltage,and3Vto5Vindicatehighvoltage.WhentheEMUorEMUAinputalarmsareofthevoltagetype,0Vto0.7Vindicatelow
voltage,and5Vto12Vindicatehighvoltage.

4.4FeatureDeployment
4.4.1DeploymentProcedure
Thereisnofixedsequenceforconfiguringthemonitoringmanagementfeature.

4.4.2DeploymentRequirements
None

4.4.3DataPreparation
GenericData
None

ScenariospecificData
Thefollowingscenarioscanbeusedtogether.Iftheyareusedtogether,dataforallthesescenariosmustbeprepared.

Scenario1:ConfiguringthePMU
FortheparametersettingsforthePMU,seePowerManagementFeatureParameterDescription.

Scenario2:ConfiguringtheFMU
Table43describestheparametersettingsfortheFMU.
Table43ParametersettingsfortheFMU
Parameter
Name

Parameter
ID

SettingDescription

Source

Thisparameterspecifiesthenumberofthe
cabinethousingtheFMU.
CabinetNo.

CN

IfthenumberoftheRFChousingtheFMUis1,
setthisparameterto1.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.

Network
plan

Thisparameterspecifiesthenumberofthe
subrackhousingtheFMU.
SubrackNo.

SRN

SlotNo.

SN

Setthisparameterto11or12.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberoftheslot
housingtheFMU.
Setthisparametertothedefaultvalue0.

Network
plan

Network
plan

Manager
CabinetNo.

Manager
SubrackNo.

MCN

ThemanageroftheFMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothecabinet
numberoftheBBU,CCU,orRRU.
TheFMUisnotdirectlyconnectedtotheRRU.
Therefore,setthisparametertothecabinet
numberoftheBBUorCCUthatconnectstothe
FMU.
ThemanageroftheFMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothesubrack
numberoftheBBU,CCU,orRRU.

MSRN

TheFMUisnotdirectlyconnectedtotheRRU.
Therefore,setthisparametertothesubrack
numberoftheBBUorCCUthatconnectstothe
FMU.

Network
plan

Network
plan

Thisparameterspecifiesthenumberoftheserial
portonthemanagertowhichtheFMUis
connected.
ManagerPort
No.

MPN

IftheFMUisconnectedtotheBBU:
UPEU/UEIU(MON1):1

Network
plan

UPEU/UEIU(MON0):0

IftheFMUisconnectedtotheCCU,itmustbe
connectedtoportD_COM1.Setthisparameterto1.
Thisparameterspecifiesthecommunication
addressoftheFMU.AmaximumoftwoFMUs
canbeconfiguredonanRS485bus.
Address

ADDR

Setthisparameterasfollows:

Network
plan

UpperlevelFMUintwocascadedFMUs:14

LowerlevelFMUintwocascadedFMUs:15

Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
SpecialBoolean
AlarmFlag

SBAF

Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled)andSS_DISABLE(Smog
SensorDisabled).
ItisrecommendedthattheFMUnotbe
connectedtoexternalsensorsandallsensorsbe
disabled.Ifyouwanttousethesensors,contact
Huaweitechnicalsupport.
Retainthedefaultsettings,whichmeanthatall
sensorsaredisabled.

Network
plan

Thisparameterspecifieswhethertoenablesmart
temperaturecontrol.

Smart
Temperature
Control

WhenthisparameterissettoENABLED,the
cabinetadjuststhefanspeedaccordingtothe
TRXtemperature.Inthismode,thefannoiseis
low.
STC

WhenthisparameterissettoDISABLED,the
cabinetadjuststhefanspeedaccordingtothe
temperatureattheairintakevent.Inthismode,
thefannoiseishigh.

Network
plan

ThisparametercanbesettoDISABLEDor
ENABLED.
ENABLEDisrecommended.
Thisparameterspecifieswhichmodeisusedto
adjustthefanspeed.
Valuerange:0to65535
0:defaultmode.Thismodeachievesatradeoff
amongpowerconsumption,noise,and
temperaturecontrol.Itappliestomost
scenarios.
9:synchronizationmode.Thismodebringslow
noisebutpoortemperaturecontroleffects.
Inappropriateuseofthismodemayleadto
seriousresults,forexample,theservicesonthe
RFmoduleareinterrupteddueto
overtemperature.ContactHuaweitechnical
supportbeforeusingthismode.

Temperature
ControlMode

TCMODE

Othervalues:Thedefaultmodetakeseffect.

Network
Plan

Scenario3:ConfiguringtheTCU
Table44describestheparametersettingsfortheTCU.
Table44ParametersettingsfortheTCU
Parameter
Name

Parameter
ID

SettingDescription

Source

Thisparameterspecifiesthenumberofthe
cabinethousingtheTCU.
CabinetNo.

SubrackNo.

CN

SRN

IfthenumberoftheAPM30Hcabinethousingthe
TCUis0,setthisparameterto0.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberofthe
subrackhousingtheTCU.
Setthisparameterto8or14.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.

Network
plan

Network
plan

Thisparameterspecifiesthenumberoftheslot
housingtheTCU.
IftheTCUisinstalledintheBTS3900ALAC,
BTS3900ALDC,IBBS700D,orIBBS700T
cabinet,setthisparameterasfollows:
SettheslotnumberoftheCMUFto0.
SettheslotnumberofHAU0to1.

SettheslotnumberofHAU1to2.

SlotNo.

SN

IftheTCUisinstalledintheTP48600Acabinet,
setthisparameterasfollows:

Network
plan

SettheslotnumberoftheCMUFforcabinet
temperaturecontrolto0.
SettheslotnumberoftheCMUFforbattery
cabinettemperaturecontrolto1.
SettheslotnumberofHAU0to2.

SettheslotnumberofHAU1to3.

IftheTCUisinstalledonothercabinet,setthis
parameterto0.
Manager
CabinetNo.
Manager
SubrackNo.

MCN

ThemanageroftheTCUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothecabinet
numberoftheBBU,CCU,orRRU.

Network
plan

MSRN

ThemanageroftheTCUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothesubrack
numberoftheBBU,CCU,orRRU.

Network
plan

Thisparameterspecifiesthenumberoftheserial
portonthemanagertowhichtheTCUis
connected.
Setthisparameterasfollows:
IftheTCUisconnectedtotheBBU:
UPEU/UEIU(MON1):1

ManagerPort
No.

MPN

UPEU/UEIU(MON0):0

IftheTCUisconnectedtotheCCU:
CMUFispermanentlyconnectedtoport

D_COM0,setthisparameterto0
FAU0andFAU1arepermanentlyconnectedto

portD_COM3,setthisparameterto3
IftheTCUisconnectedtotheRRU,setthis
parameterto0.
Thisparameterspecifiesthecommunication
addressoftheTCU.
IntheAPM30HorTMC11Hcabinet,amaximum
oftwoTCUscanbeconfiguredonanRS485bus.
Setthisparameterasfollows:
UpperlevelTCUintwocascadedTCUs:7

LowerlevelTCUintwocascadedTCUs:6

Network
plan

IntheIBBS200D/IBBS200Tcabinet,amaximum
offourTCUscanbeconfiguredonanRS485
bus.
Setthisparameterasfollows:
IftheupperlevelTCUismanagedbythePMU
whosecommunicationaddressis3,setthis
parameterto23.IfthelowerlevelTCUis
managedbythisPMU,setthisparameterto24.

Address

ADDR

Network
plan

IftheupperlevelTCUismanagedbythePMU
whosecommunicationaddressis4,setthis
parameterto25.IfthelowerlevelTCUis
managedbythisPMU,setthisparameterto26.
IftheHAUsareinstalled,amaximumoftwo
TCUscanbeconfiguredonanRS485bus.

Setthisparameterasfollows:
UpperlevelTCUintwocascadedTCUs:28

LowerlevelTCUintwocascadedTCUs:29

IftheCMUFisinstalled,onlyoneTCUcanbe
configuredonanRS485bus.Setthisparameter
to7.

Temperature
AlarmLower
Threshold

TLTHD

Thisparameterspecifiesthelowertemperature
limitforthecabinet.Ifthetemperatureexceeds
thelowerlimit,theNodeBoreNodeBreportsthe
alarmALM25652CabinetTemperature
Unacceptable.

Network
plan

Thedefaultvalueisrecommendedforthis
parameter.

Temperature
AlarmUpper
Threshold

TUTHD

Thisparameterspecifiestheuppertemperature
limitforthecabinet.Ifthetemperatureexceeds
theupperlimit,theNodeBoreNodeBreportsthe
alarmALM25652CabinetTemperature
Unacceptable.
Setthisparameterto50fortheTCUintheBBC.

Network
plan

Setthisparameterto68fortheTCUinother
cabinets.

SpecialBoolean
AlarmFlag

SBAF

Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled)andSS_DISABLE(Smog
SensorDisabled).
ItisrecommendedthattheTCUnotbe
connectedtoexternalsensorsandallsensorsbe
disabled.Ifyouwanttousethesensors,contact
Huaweitechnicalsupport.

Network
plan

Retainthedefaultsettings,whichmeanthatall
sensorsaredisabled.

Scenario4:ConfiguringtheCCU
Table45describestheparametersettingsfortheCCU.
Table45ParametersettingsfortheCCU
ParameterName

Parameter
ID

SettingDescription

Source

Thisparameterspecifiesthenumberofthe
cabinethousingtheCCU.
IfthenumberoftheBTS3900ALcabinet
housingtheCCUis0,setthisparameterto0.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.

Network
plan

CabinetNo.

CN

SubrackNo.

SRN

Thisparameterspecifiesthenumberofthe
subrackhousingtheCCU.Setthisparameterto
thedefaultvalue15.

Network
plan

SlotNo.

SN

Thisparameterspecifiesthenumberoftheslot
housingtheCCU.
Setthisparametertothedefaultvalue0.

Network
plan

ManagerCabinet
No.

MCN

ThemanageroftheCCUisgenerallytheBBU
orRRU.Setthisparametertothecabinet
numberoftheBBUorRRU.
TheCCUcanonlybemanagedbytheBBU.

Network
plan

ManagerSubrack
No.

MSRN

ThemanageroftheCCUisgenerallytheBBU
orRRU.Setthisparametertothesubrack
numberoftheBBUorRRU.
TheCCUcanonlybemanagedbytheBBU.

Network
plan

ManagerPortNo.

MPN

Thisparameterspecifiesthenumberofthe
serialportonthemanagertowhichtheCCUis
connected.
TheCCUmustbeconnectedtoportMON0on
theBBU.Therefore,thisparametermustbeset
to0.

Network
plan

ThisparameterspecifieswhethertheCCUis
directlyconnectedtoitsmanager.
DirectConnectFlag

CascadeNo.

Connected
Standard

SpecialBoolean
AlarmFlag

DCF

IftheCCUisdirectlyconnectedtoitsmanager,
setthisparametertoYES.
IftheCCUisconnectedtoitsmanagerovera
cascadingCCU,setthisparametertoNO.

Network
plan

CCN

Thisparameterspecifiestheinsertedpositionof
theCCUonaCCUcascadedlink.Setthis
parameterto1fortheleftmostCCUonthelink
(theCCUwhoseportFE_Lisnotconnected).
Setthisparametertoanintegerinascending
orderfortheotherCCUsonthelink.

Network
plan

CS

Thisparameterspecifiesthenetwork
technologytypeoftheBBUthatisdirectly
connectedtotheCCU.Setthisparameterto
GSM,UMTS,orLTE.
TheparameterisvalidonlywhentheDCFisset
toYes.

Network
plan

SBAF

Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled)andSS_DISABLE(Smog
SensorDisabled).
ItisrecommendedthattheCCUnotbe
connectedtoexternalsensorsandallsensors
bedisabled.Ifyouwanttousethesensors,
contactHuaweitechnicalsupport.

Network
plan

Retainthedefaultsettings,whichmeanthatthe
watersensorandsmokesensoraredisabled.

Scenario6:ConfiguringCustomizedAlarms
Topreparedataforcustomizedalarmconfiguration,performthefollowingsteps:
Step1PrepareEMUconfigurationdata.
Beforedatapreparation,checkwhethertheEMUneedstobeconfiguredbyreferringtoTable42.IftheEMUisrequired,prepareEMU
configurationdatabyreferringtoTable46.Otherwise,skipthisstep.
Step2Prepareconfigurationdataofthealarmsignalinputandoutputportsbasedontheinputandoutputrequirementsofcustomized
alarms.
PrepareconfigurationdataoftheenvironmentalalarmsignalinputportALMPORTbyreferringtoTable47.
PrepareconfigurationdataoftheenvironmentalalarmsignaloutputportOUTPORTbyreferringtoTable48.

End
Table46ParametersettingsfortheEMU
Parameter
Name

Parameter
ID

SettingDescription

Source

CabinetNo.

CN

Thisparameterspecifiesthenumberofthe
cabinethousingtheEMU.

Network
plan

SubrackNo.

SRN

Thisparameterspecifiesthenumberofthe
subrackhousingtheEMU.
Setthisparametertothedefaultvalue.

Network
plan

SlotNo.

SN

Thisparameterspecifiesthenumberoftheslot
housingtheEMU.
Setthisparametertothedefaultvalue.

Network
plan

Manager
CabinetNo.

MCN

ThemanageroftheEMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothecabinet
numberoftheBBU,CCU,orRRU.

Network
plan

Manager
SubrackNo.

MSRN

ThemanageroftheEMUisgenerallytheBBU,
CCU,orRRU.Setthisparametertothesubrack
numberoftheBBU,CCU,orRRU.

Network
plan

Thisparameterspecifiesthenumberoftheserial
portonthemanagertowhichtheEMUis
connected.Setthisparameterasfollows:
IftheEMUisconnectedtotheBBU:
ManagerPort
No.

UPEU/UEIU(MON1):1

MPN

UPEU/UEIU(MON0):0

Network
plan

IftheEMUisconnectedtotheCCU,itmustbe
connectedtoportD_COM3.Setthisparameterto
3.
IftheEMUisconnectedtotheRRU,setthis
parameterto0.
Address

Temperature
AlarmLower
Threshold

ADDR

TLTHD

Thisparameterspecifiesthecommunication
addressoftheEMU.
Setthisparameterto2.
Thisparameterspecifiesthelowerambient
temperaturelimit.Iftheambienttemperature
exceedsthelowerlimit,theNodeBoreNodeB
reportsthealarmALM25650Ambient
TemperatureUnacceptable.
Thisparameterneedstobeconfiguredonlywhen
TS_DISABLEinSAAFiscleared.

Network
plan

Network
plan

Thedefaultvalueisrecommendedforthis
parameter.

Temperature
AlarmUpper
Threshold

TUTHD

Thisparameterspecifiestheupperambient
temperaturelimit.Iftheambienttemperature
exceedstheupperlimit,theNodeBoreNodeB
reportsthealarmALM25650Ambient
TemperatureUnacceptable.
Thisparameterneedstobeconfiguredonlywhen
TS_DISABLEinSAAFiscleared.

Network
plan

Thedefaultvalueisrecommendedforthis
parameter.

HumidityAlarm
Lower
Threshold

HLTHD

Thisparameterspecifiesthelowerambient
humiditylimit.Iftheambienthumidityexceedsthe
lowerlimit,theNodeBoreNodeBreportsthe
alarmALM25651AmbientHumidity
Unacceptable.
Thisparameterneedstobeconfiguredonlywhen
HS_DISABLEinSAAFiscleared.

Network
plan

Thedefaultvalueisrecommendedforthis
parameter.

HumidityAlarm
Upper
Threshold

HUTHD

Thisparameterspecifiestheupperambient
humiditylimit.Iftheambienthumidityexceedsthe
upperlimit,theNodeBoreNodeBreportsthe
alarmALM25651AmbientHumidity
Unacceptable.
Thisparameterneedstobeconfiguredonlywhen
HS_DISABLEinSAAFiscleared.

Network
plan

Thedefaultvalueisrecommendedforthis
parameter.
Thisparameterspecifieswhethertoreporta
dedicatedanalogalarm.Iftheshieldflagforan
analogalarmisselected,theanalogalarmcannot
bereported.

SpecialAnalog

Valuerange:48V_DISABLE(48Voltage
Disabled),RES0(ReservedSensor0),
RES1(ReservedSensor1),RES2(Reserved
Sensor2),TS_DISABLE(TemperatureSensor
Disabled),andHS_DISABLE(HumiditySensor
Disabled).

Network

AlarmFlag

SAAF

Setthisparameterasfollows:
The48Valarmisusedtocheckwhetherthe
inputvoltageforthecabinetisnormal.When
theinputvoltageforthecabinetis48V,itis
recommendedthat48V_DISABLEbecleared.

plan

RES0,RES1,andRES2areparameters
reservedbyHuaweiandtheyareselected.
SetTS_DISABLEandHS_DISABLEbasedon
thetypesofsensorsconnectedtotheEMUor
EMUA.

Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.
SpecialBoolean
AlarmFlag

SBAF

Valuerange:WS_DISABLE(WaterImmersed
SensorDisabled),SS_DISABLE(SmogSensor
Disabled),IS_DISABLE(InfraredSensor
Disabled),andGS_DISABLE(GatingSensor
Disabled).

Network
plan

Itisrecommendedthatthisparameterbeset
basedonthetypesofsensorsconnectedtothe
EMUorEMUA.

Table47ParametersettingsfortheALMPORT
Parameter
Name

Parameter
ID

SettingDescription

Source

CabinetNo.

CN

Thisparameterspecifiesthecabinetnumberof
theboardwheretheALMPORTportislocated.

Network
plan

SubrackNo.

SRN

Thisparameterspecifiesthesubracknumberof
theboardwheretheALMPORTportislocated.

Network
plan

SlotNo.

SN

Thisparameterspecifiestheslotnumberofthe
boardwheretheALMPORTportislocated.

Network
plan

Thisparameterspecifiesthenumbersofthe
alarmportsoneachmonitoringboardasfollows:
PortNo.

PN

UPEU/UEIU:0to7(forBooleanalarms)
RRU:0to3(forBooleanalarms)

Network
plan

EMU/EMUA:0to31(forBooleanalarms)
EMU/EMUA:32to35(foranalogalarms)

Switch

AlarmID

SW

Ifacustomizedalarminputisrequired,theswitch
mustbeturnedon.Thisparameterspecifiesthe
stateoftheportswitchandcanbesetasfollows:
OFF(Off):indicatesthattheportisdisabledand
alarmscannotbedetected.Thisisthedefault
valueforthisparameter.
ON(On):indicatesthattheportisenabledand
alarmscanbereportedthroughtheport
accordingtothecustomizedalarmIDs.In
addition,thealarmvoltagelevelforBoolean
alarmsorthealarmupper/lowerlimitcanbeset
inthisparameter.

Network
plan

AID

ThisparameterspecifiesthealarmIDpertaining
tothealarmport.Ifanalarmisdetectedthrough
theport,thevalueofthisparameterisusedas
thealarmIDandisreportedwiththealarm.The
valuerangeofthisparameteris65033to65233.
Thealarmname,alarmseverity,andOSStype
correspondingtothealarmIDareconfiguredon
theM2000client.

Network
plan

Thisparameterspecifiesthetypeofanalarm
port.ItcanbesettoBOOL(DigitalPort)or
VALUE(AnalogPort).
PortType

PT

Ananalogport,providedbytheEMUorEMUA,
monitorstheexternalenvironment.
Adigitalport,providedbytheUPEU,UEIU,RRU,
EMU,orEMUA,monitorstheexternal
environmentwithBooleanordiscretevalues.
ThisparameterisvalidonlywhenPTissetto
BOOL.

Network
plan

AlarmVoltage

AVOL

Thisparameterspecifieswhetherthesensor
sendstheportahighlevelorlowlevelalarm.Set
thisparameterbasedonalarmcableconnection.
Fordetailsaboutthepinassignmentforthewires
ofalarmcables,see:
Section"BBUAlarmCable"inthebasestation
specifichardwaredescription.

Network
plan

Section"RRUAlarmCable"intheRRUspecific

hardwaredescription.
Section"RS485SerialPort"inEMUUserGuide

andEMUAUserGuide.

AlarmUpper
Limit

UL

Thisparameterspecifiesthealarmupperlimit.If
theenvironmentmeasurementvalueisgreater
thanthealarmupperlimitofthesensor,the
NodeBoreNodeBreportsthealarm.
Environmentmeasurementvalue=Measurement
lowerlimit+(Measurementupperlimit
Measurementlowerlimit)x(Observedcurrentor
voltageOutputlowerlimit)/(Outputupperlimit
Outputlowerlimit).
ULmustbesmallerthanorequaltoSMULand
greaterthanLL.

Network
plan

Thisparameterspecifiesthealarmlowerlimit.If
theenvironmentmeasurementvalueissmaller
thanthealarmlowerlimitofthesensor,the
NodeBoreNodeBreportsthealarm.
AlarmLower
Limit

SensorType

Sensor
Measurement
UpperLimit

LL

ST

SMUL

Environmentmeasurementvalue=Measurement
lowerlimit+(Measurementupperlimit
Measurementlowerlimit)x(Observedcurrentor
voltageOutputlowerlimit)/(Outputupperlimit
Outputlowerlimit).
LLmustbegreaterthanorequaltoSMLLand
smallerthanUL.
Thisparameterspecifiesthetypeofasensor.
SetthisparametertoVOLTAGE(VoltageType)
orCURRENT(CurrentType)basedonthe
externalsensorspecifications.
ThisparameterisvalidonlywhenPTissetto
VALUE.
Thisparameterspecifiesthemeasurementupper
limitoftheanalogport.Setthisparameterbased
onthesiteconditions,suchasthetemperature
andhumidity.
SMULmustbegreaterthanorequaltoUL.

Network
plan

Network
plan

Network
plan

SMULmustbegreaterthanSMLL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
Sensor
Measurement
LowerLimit

SMLL

Thisparameterspecifiesthemeasurementlower
limitoftheanalogport.Setthisparameterbased
onthesiteconditions,suchasthetemperature
andhumidity.
SMLLmustbesmallerthanorequaltoLL.

Network
plan

SMLLmustbesmallerthanSMUL.

SensorOutput
UpperLimit

SensorOutput
LowerLimit

SOUL

ThisparameterisvalidonlywhenPTissetto
VALUE.
Thisparameterspecifiestheoutputsignalupper
limitoftheanalogport.Forasensorofeitherthe
currenttypeorthevoltagetype,setthis
parameterbasedontheexternalsensor
specifications.
SOULmustbegreaterthanSOLL.

Network
plan

SOLL

ThisparameterisvalidonlywhenPTissetto
VALUE.
Thisparameterspecifiestheoutputsignallower
limitoftheanalogport.Forasensorofeitherthe
currenttypeorthevoltagetype,setthis
parameterbasedontheexternalsensor
specifications.
SOLLmustbesmallerthanSOUL.

Network
plan


Table48ParametersettingsfortheOUTPORT
Parameter
Name

Parameter
ID

SettingDescription

Source

CabinetNo.

CN

Thisparameterspecifiesthecabinetnumberof
theboardwheretheOUTPORTportislocated.

Network
plan

SubrackNo.

SRN

Thisparameterspecifiesthesubracknumberof
theboardwheretheOUTPORTportislocated.

Network
plan

SlotNo.

SN

Thisparameterspecifiestheslotnumberofthe
boardwheretheOUTPORTportislocated.

Network
plan

PortNo.

PN

Valuerange:0to5

Network
plan

PortName

NAME

Theconfigurationofthisparameterisoptional.If
configured,thisparametercanbecustomized.

Network
plan

PortSwitch

Thisswitchisturnedonbasedonthemonitoring
deviceconfiguration.

SW

Toenableaport,setthisparametertoON.
Todisableaport,setthisparametertoOFF.

Network
plan

ReferenceforConfiguringtheMonitoringFunction
Themonitoringfunctionshouldbeconfiguredbasedonthehardwareinstalledinacabinet.Thissectiondescribeshowtoconfigurethe
monitoringfunctionintypicalbasestationcabinets.Monitoringfunctionconfigurationsinvolvethesettingsofparameterssuchas
cabinetnumber,subracknumber,slotnumber,boardtype,cabinetnumberofaboardmanager,subracknumberofaboardmanager,
serialportnumber,andcommunicationaddress.Fordetailsaboutthesettingsofotherparameters,seesection"Scenariospecific
Data."
ThissectiondescribestheconfigurationsintheVer.CcabinetsfortheBTS3900andBTS3900L.TheconfigurationsintheVer.Bcabinetsarethesameas
thoseintheVer.Ccabinets,exceptthattheFMUEisreplacedwiththeFMUC.TheconfigurationsintheVer.DcabinetsarethesameasthoseintheVer.C
cabinets,exceptthattheFMUEisreplacedwiththeFMUEA.
ThissectionalsodescribestheconfigurationsintheVer.CcabinetsfortheBTS3900AandDBS3900.TheconfigurationsintheVer.Bcabinetsarethesameas
thoseintheVer.Ccabinets,exceptthattheCMUEisreplacedwiththeCMUA.TheconfigurationsintheVer.DcabinetsarethesameasthoseintheVer.C
cabinets,exceptthattheCMUEisreplacedwiththeCMUEAandnoHPMIisconfigured.

Scenario1:ExampleofConfigurationsinaBTS3900(48VDC)
Figure41showstheconnectionsofmonitoringsignalcablesinaBTS3900(48VDC)housedintwocabinets.
Figure41ConnectionsofmonitoringsignalcablesinaBTS3900(48VDC)

Table49describestheconfigurationsofmonitoringboardsinaBTS3900(48VDC).
Table49ConfigurationsofmonitoringboardsinaBTS3900(48VDC)
Cabinet

Cabinet0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Remarks

BTS3900

50

GATM0

22

ForBTS
only

51

GATM1

22

ForBTS
only

11

FMU

14

FMUE

40

EMU

EMU,
optional

Cabinet1

BTS3900

11

FMU

15

FMUE

Scenario2:ExampleofConfigurationsinaBTS3900(AC)
Figure42showstheconnectionsofmonitoringsignalcablesinaBTS3900(AC)housedintwocabinets.
Figure42ConnectionsofmonitoringsignalcablesinaBTS3900(AC)

Table410describestheconfigurationsofmonitoringboardsinaBTS3900(AC)housedintwocabinets.
Table410ConfigurationsofmonitoringboardsinaBTS3900(AC)
Cabinet

Cabinet0

Cabinet1

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

BTS3900

PMU

11

FMU

14

40

EMU

EMU,optional

11

FMU

15

PMU

BTS3900

Scenario3:ExampleofConfigurationsinaBTS3900L(48VDC)
Figure43_Ref313028199showstheconnectionsofmonitoringsignalcablesinaBTS3900L(48VDC)cabinet.
Figure43ConnectionsofmonitoringsignalcablesinaBTS3900L(48VDC)

Table411describestheconfigurationsofmonitoringboardsinaBTS3900L(48VDC)cabinet.

Table411ConfigurationsofmonitoringboardsinaBTS3900L(48VDC)
Cabinet

Cabinet0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

BTS3900L

40

EMU

EMU,optional

50

GATM0

22

ForBTSonly

51

GATM1

22

ForBTSonly

11

FMU

14

12

FMU

15

Scenario4:ExampleofConfigurationsinaBTS3900A(AC)
Figure44showstheconnectionsofmonitoringsignalcablesinaBTS3900A(AC)housedinoneAPM30Hcabinet,oneRFCcabinet,
twoIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure44ConnectionsofmonitoringsignalcablesinaBTS3900A(1APM30H+1RFC+2IBBS200D/IBBS200T+1TMC11H)

Table412describestheconfigurationsofmonitoringboardsinaBTS3900A(AC)housedinoneAPM30Hcabinet,oneRFCcabinet,
twoIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table412ConfigurationsofmonitoringboardsinaBTS3900A(1APM30H+1RFC+2IBBS200D/IBBS200T+1TMC11H)
Cabinet

APM30H0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

APM30

TCU

CMUE

PMU

50

GATM0

22

ForBTSonly

51

GATM1

22

ForBTSonly

40

EMU

EMUA,
optional

RFC0

RFC

11

FMU

14

CMUE

TMC11H0

TMC

TCU

CMUE

IBBS200D/IBBS200T0

BBC

TCU

23

CMUE

IBBS200D/IBBS200T1

BBC

10

TCU

24

CMUE

Figure45showstheconnectionsofmonitoringsignalcablesinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
andtwoIBBS200D/IBBS200Tcabinets.
Figure45ConnectionsofmonitoringsignalcablesinaBTS3900A(2APM30H+2RFC+2IBBS200D/IBBS200T)


Table413describestheconfigurationsofmonitoringboardsinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
andtwoIBBS200D/IBBS200Tcabinets.
Table413ConfigurationsofmonitoringboardsinaBTS3900A(2APM30H+2RFC+2IBBS200D/IBBS200T)
Cabinet

APM30H0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

APM30

PMU

TCU

CMUE

50

GATM0

22

ForBTSonly

51

GATM1

22

ForBTSonly

40

EMU

EMUA,
optional

RFC0

RFC

11

FMU

14

CMUE

RFC1

RFC

11

FMU

15

CMUE

APM30H0

APM30

PMU

TCU

CMUE

IBBS200D/IBBS200T0

BBC

TCU

23

CMUE

IBBS200D/IBBS200T2

BBC

11

TCU

23

CMUE

Figure46showstheconnectionsofmonitoringsignalcablesinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
fourIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure46ConnectionsofmonitoringsignalcablesinaBTS3900A(2APM30H+2RFC+4IBBS200D/IBBS200T+1TMC11H)

Table414describestheconfigurationsofmonitoringboardsinaBTS3900A(AC)housedintwoAPM30Hcabinets,twoRFCcabinets,
fourIBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table414ConfigurationsofmonitoringboardsinaBTS3900A(2APM30H+2RFC+4IBBS200D/IBBS200T+1TMC11H)

Cabinet

APM30H0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

APM30

PMU

TCU

CMUE

50

GATM0

22

ForBTSonly

51

GATM1

22

ForBTSonly

40

EMU

EMUA,
optional

RFC0

RFC

11

FMU

14

CMUE

RFC1

RFC

11

FMU

15

CMUE

APM30H1

APM30

PMU

TCU

CMUE

TMC11H0

TMC

TCU

IBBS200D/IBBS200T0

BBC

TCU

23

CMUE

IBBS200D/IBBS200T1

BBC

10

TCU

24

CMUE

IBBS200D/IBBS200T2

BBC

11

TCU

23

CMUE

IBBS200D/IBBS200T3

BBC

12

TCU

24

CMUE

Scenario5:ExampleofConfigurationsinaBTS3900A(48VDC)
Figure47showstheconnectionsofmonitoringsignalcablesinaBTS3900A(48VDC)housedintwoTMC11HcabinetsandtwoRFC
cabinets.IfcabinetTMC11H1isnotconfigured,connecttheCMUEincabinetRFC0totheCMUEincabinetRFC1.Ignorethe
configurationdataofcabinetTMC11H1inTable415.
Figure47ConnectionsofmonitoringsignalcablesinaBTS3900A(2TMC11H+2RFC)

Table415describestheconfigurationsofmonitoringboardsinaBTS3900AhousedintwoTMC11HcabinetsandtwoRFCcabinets.
Table415ConfigurationsofmonitoringboardsinaBTS3900A(2TMC11H+2RFC)
Cabinet

TMC11H0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

TMC

TCU

CMUE

50

GATM0

22

ForBTSonly

51

GATM1

22

ForBTSonly

40

EMU

EMUA,
optional

RFC0

RFC

11

FMU

14

CMUE

RFC1

RFC

11

FMU

15

CMUE

TMC11H1

TMC

TCU

CMUE

Scenario6:ExampleofConfigurationsinaDBS3900(AC)
Figure48showstheconnectionsofmonitoringsignalcablesinaDBS3900(AC)housedintwoAPM30Hcabinets,two
IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure48ConnectionsofmonitoringsignalcablesinaDBS3900(2APM30H+2IBBS200D/IBBS200T+1TMC11H)

Table416describestheconfigurationsofmonitoringboardsinaDBS3900(AC)housedintwoAPM30Hcabinets,two
IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table416ConfigurationsofmonitoringboardsinaDBS3900(2APM30H+2IBBS200D/IBBS200T+1TMC11H)
Cabinet

APM30H0

APM30H1

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

APM30

PMU

TCU

CMUE

40

EMU

EMUA,
optional

PMU

TCU

CMUE

APM30

TMC11H0

TMC

TCU

CMUE

IBBS200D/IBBS200T0

BBC

TCU

23

CMUE

IBBS200D/IBBS200T2

BBC

11

TCU

23

CMUE

Figure49showstheconnectionsofmonitoringsignalcablesinaDBS3900(AC)housedintwoAPM30Hcabinets,four
IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Figure49ConnectionsofmonitoringsignalcablesinaDBS3900(2APM30H+4IBBS200D/IBBS200T+1TMC11H)

Table417describestheconfigurationsofmonitoringboardsinaDBS3900(AC)housedintwoAPM30Hcabinets,four

IBBS200D/IBBS200Tcabinets,andoneTMC11Hcabinet.
Table417ConfigurationsofmonitoringboardsinaDBS3900(2APM30H+4IBBS200D/IBBS200T+1TMC11H)
Cabinet

APM30H0

APM30H1

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

APM30

PMU

TCU

CMUE

40

EMU

EMUA,
optional

PMU

TCU

CMUE

APM30

TMC11H0

TMC

TCU

CMUE

IBBS200D/IBBS200T0

BBC

TCU

23

CMUE

IBBS200D/IBBS200T1

BBC

10

TCU

24

CMUE

IBBS200D/IBBS200T2

BBC

11

TCU

23

CMUE

IBBS200D/IBBS200T3

BBC

12

TCU

24

CMUE

Figure410showstheconnectionsofmonitoringsignalcablesinaDBS3900intheremotemonitoringscenario.
Figure410ConnectionsofmonitoringsignalcablesinaDBS3900intheremotemonitoringscenario

Table418describestheconfigurationsofmonitoringboardsinaDBS3900intheremotemonitoringscenario.
Table418ConfigurationsofmonitoringboardsinaDBS3900intheremotemonitoringscenario
Cabinet

APM30H0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

APM30

10

PMU

Cabinet
numberof
theRRU
that
connects
tothis
PMU

Subrack
numberof
theRRU
that
connects
tothis
PMU

10

TCU

Cabinet
numberof
theRRU
that
connects
tothis
TCU

Subrack
numberof
theRRU
that
connects
tothis
TCU

CMUE

10

40

EMU

Cabinet
numberof
theRRU
that
connects
tothis

Subrack
numberof
theRRU
that
connects
tothis

EMU

EMU

IBBS200D/IBBS200T0

BBC

11

TCU

Cabinet
numberof
theRRU
that
connects
tothis
TCU

Subrack
numberof
theRRU
that
connects
tothis
TCU

23

CMUE

IBBS200D/IBBS200T1

BBC

12

TCU

Cabinet
numberof
theRRU
that
connects
tothis
TCU

Subrack
numberof
theRRU
that
connects
tothis
TCU

24

CMUE

Figure411showstheconnectionsofmonitoringsignalcablesinaDBS3900(AC)thathastheBBUinstalledinanOMBcabinet.
Figure411ConnectionsofmonitoringsignalcablesinaDBS3900(1OMB)

Table419describestheconfigurationsofmonitoringboardsinaDBS3900(AC)thathastheBBUinstalledinanOMBcabinet.
Table419ConfigurationsofmonitoringboardsinaDBS3900(1OMB)
Cabinet

OMB

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

OMB

PMU

TCU

HEUA

Figure412showstheconnectionsofmonitoringsignalcablesinaDBS3900(110V/220VAC)deployedinBBU+RRU+ICRmode.The
BBUandPMUareinstalledontheupperandlowerracksrespectivelyinanIMBcabinet.
Figure412ConnectionsofmonitoringsignalcablesinaDBS3900(BBU+RRU+ICR)

Table420describestheconfigurationsofmonitoringboardsinaDBS3900(110V/220VAC)deployedinBBU+RRU+ICRmode.
Table420ConfigurationsofmonitoringboardsinaDBS3900(BBU+RRU+ICR)
Cabinet

IMB03

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

Virtual

PMU

Figure413showstheconnectionsofmonitoringsignalcablesinaDBS3900(110V/220VAC)deployedinBBU+RRU+IMBmode.The
BBUisinstalledinanIMBcabinetandtheRRUisinstalledoutdoors.
Figure413ConnectionsofmonitoringsignalcablesinaDBS3900(BBU+RRU+IMB)


Table421describestheconfigurationsofmonitoringboardsinaDBS3900(110V/220VAC)deployedinBBU+RRU+IMBmode.
Table421ConfigurationsofmonitoringboardsinaDBS3900(BBU+RRU+IMB)
Cabinet

IMB03

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

Virtual

PMU

Scenario7:ExampleofConfigurationsinaDBS3900(48VDC)
Figure414showstheconnectionsofmonitoringsignalcablesinaDBS3900(48VDC)housedintwoTMC11Hcabinets.
Figure414ConnectionsofmonitoringsignalcablesinaDBS3900(2TMC11H)

Table422describestheconfigurationsofmonitoringboardsinaDBS3900(48VDC)housedintwoTMC11Hcabinets.
Table422ConfigurationsofmonitoringboardsinaDBS3900(2TMC11H)
Cabinet

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

TMC11H0

TMC

TCU

CMUE

TMC11H1

TMC

TCU

CMUE

Figure415showstheconnectionsofmonitoringsignalcablesinaDBS3900(48VDC)thathastheBBUinstalledinanOMBcabinet.
Figure415ConnectionsofmonitoringsignalcablesinaDBS3900(1OMB)

Table423describestheconfigurationsofmonitoringboardsinaDBS3900(48VDC)thathastheBBUinstalledinanOMBcabinet.
Table423ConfigurationsofmonitoringboardsinaDBS3900(1OMB)
Cabinet

OMB

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Note

OMB

TCU

HEUA

Scenario8:ExampleofConfigurationsinaBTS3900AL(AC)
Figure416showstheconnectionsofmonitoringsignalcablesinaBTS3900AL(AC)housedinoneACcabinet,oneDCcabinet,and
oneTMC11Hcabinet.IftheHAUsarenotconfigured,connecttheCMUAdirectlytoportD_COM3ontheCCU.IgnoretheHAU
configurationdataofcabinetBTS3900ALAC0inTable424Figure417Table425.
Figure416ConnectionsofmonitoringsignalcablesinaBTS3900AL(1ACcabinet+1DCcabinet+1TMC11H)


Table424describestheconfigurationsofmonitoringboardsinaBTS3900AL(1ACcabinet+1DCcabinet+1TMC11H)
Table424ConfigurationsofmonitoringboardsinaBTS3900AL(1ACcabinet+1DCcabinet+1TMC11H)
Cabinet

BTS3900AL
AC0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Otherparameter

Note

BTS3900AL

15

CCU

21

Level1whose
DirectConnectFlag
issettoYES.

Connectednetwork
technologytype:
networkservedby
theentireCCUlink

BTS3900AL
DC0

TMC11H
(Ver.C)0

BTS3900AL

TCU

15

CMUF

BTS3900AL

11

FMU

15

14

FAU

BTS3900AL

PMU

15

BTS3900AL

TCU

15

28

HAU0,
optional

BTS3900AL

TCU

15

29

HAU1,
optional

BTS3900AL

40

EMU

15

EMU,
optional

BTS3900AL

15

CCU

21

Level2whose
DirectConnectFlag
issettoNO

BTS3900AL

TCU

15

CMUF

BTS3900AL

11

FMU

15

14

FAU

BTS3900AL

TCU

15

28

HAU0,
optional

BTS3900AL

TCU

15

29

HAU1,
optional

TMC

TCU

15

CMUE

Figure417showstheconnectionsofmonitoringsignalcablesinaBTS3900AL(AC)housedinoneACcabinet,oneDCcabinet,and
oneIBBS700D/IBBS700Tcabinet.
Figure417ConnectionsofmonitoringsignalcablesinaBTS3900AL(1ACcabinet+1DCcabinet+1IBBS700D/IBBS700T)


Table425describestheconfigurationsofmonitoringboardsinaBTS3900AL(AC)housedinoneACcabinet,oneDCcabinet,and
oneIBBS700D/IBBS700Tcabinet.
Table425ConfigurationsofmonitoringboardsinaBTS3900AL(1ACcabinet+1DCcabinet+1IBBS700D/IBBS700T)
Cabinet

BTS3900ALAC0

Cabinet
Type

MonitoringBoardConfiguration
CN

SRN

SN

BT

MCN

MSRN

MPN

ADDR

Otherparameter

Note

BTS3900AL

15

CCU

21

Level1whose
DirectConnectFlag
issettoYES.

Connectednetwork
technologytype:
networkservedby
theentireCCUlink

BTS3900ALDC0

IBBS700D/IBBS700T0

4.4.4Precautions

BTS3900AL

TCU

15

CMUF

BTS3900AL

11

FMU

15

14

FAU

BTS3900AL

PMU

15

BTS3900AL

TCU

15

28

HAU0,
optional

BTS3900AL

TCU

15

29

HAU1,
optional

BTS3900AL

40

EMU

15

EMU,
optional

BTS3900AL

15

CCU

21

Level2whose
DirectConnectFlag
issettoNO

BTS3900AL

TCU

15

CMUF

BTS3900AL

11

FMU

15

14

FAU

BTS3900AL

TCU

15

28

HAU0,
optional

BTS3900AL

TCU

15

29

HAU1,
optional

BBC

15

CCU

21

Level3whose
DirectConnectFlag
issettoNO

BBC

TCU

15

CMUF

BBC

TCU

15

28

HAU0,
optional

BBC

TCU

15

29

HAU1,
optional

N/A

4.4.5HardwareInstallation
Seesection"InstallingMonitoringSignalCables"inthebasestationspecificinstallationguide.
WhensettingexternalBooleanalarmsbasedonthehighorlowvoltagesettings,seethefollowingsectionstoobtainthepinassignment
forthewiresofalarmcables:
Section"BBUAlarmCable"inthebasestationspecifichardwaredescription.
Section"RRUAlarmCable"intheRRUspecifichardwaredescription.
Section"RS485SerialPort"inEMUUserGuideandEMUAUserGuide.

4.4.6FeatureActivation/InitialConfiguration
Thescenariosforconfiguringmonitoringmanagementcanbeusedtogether.Iftheyareusedtogether,dataforallthesescenarios
mustbeconfigured.Thereisnofixedsequencebetweentheconfigurationscenarios.WhentheEMUorEMUAisinstalledfor
configuringcustomizedalarms,configuretheEMU,andthentheALMPORTorOUTPORT.

ConfiguringaSingleNodeBoreNodeBontheGUI
ConfigureasingleNodeBoreNodeBontheGUIbasedonprepareddata.
ToconfigurethemonitoringfunctionforaNodeB,seesection"ConfiguringaNodeB(GUIMode)>ConfiguringDeviceDataAbouta

NodeB>ConfiguringMonitoringUnits>Procedure"in3900SeriesBaseStationInitialConfiguration(SRAN7.0)>NodeBInitial
Configuration(V200R014).
ToconfigurethemonitoringfunctionforaneNodeB,seesection"InitiallyConfiguringaSingleeNodeBontheCMEGUI>Configuring
eNodeBData>ConfiguringeNodeBDeviceData>ConfiguringMonitoringUnits>ProcedureineNodeBInitialConfigurationGuideor
in3900SeriesBaseStationInitialConfiguration(SRAN7.0)>eNodeBInitialConfiguration(V100R005).

ConfiguringNodeBsoreNodeBsinBatches
SavetheprepareddataofaNodeBoreNodeBasatemplate.ConfigureNodeBsoreNodeBsinbatchesontheGUIbyimportingthe
template.Fordetails,see:
ToconfigurethemonitoringfunctionforNodeBs,seesection"ConfiguringaNodeB(IubCollaborationMode)"in3900SeriesBase

StationInitialConfiguration(SRAN7.0)>NodeBInitialConfiguration(V200R014).
ToconfigurethemonitoringfunctionforeNodeBs,seesection"InitiallyConfiguringeNodeBsinBatches"ineNodeBInitial

ConfigurationGuideorin3900SeriesBaseStationInitialConfiguration(SRAN7.0)>eNodeBInitialConfiguration(V100R005).

ConfiguringaSingleNodeBoreNodeBUsingMMLCommands
Scenario1:ConfiguringthePMU
FordetailsabouthowtoconfigurethePMU,seePowerManagementFeatureParameterDescription.

Scenario2:ConfiguringtheFMU
RuntheADDFMUcommandtoaddanFMU.

Scenario3:ConfiguringtheTCU
RuntheADDTCUcommandtoaddaTCU.

Scenario4:ConfiguringtheCCU
RuntheADDCCUcommandtoaddaCCU.

Scenario5:ConfiguringCustomizedAlarms
Step1(Optional)RuntheADDEMUcommandtoaddanEMU.IftheEMUisnotrequired,skipthisstep.
Step2RuntheLSTALMPORTandLSTOUTPORTcommandstoquerythestatusoftheinputandoutputalarmports,respectively.
Step3Basedonthequeryresults,runthefollowingcommandstoopentheportthatneedstobeconfiguredasaninputalarmport
andclosetheunusedalarmport:
SETALMPORT:tosettheinputalarmport
SETOUTPORT:tosettheoutputalarmport

Step4Addandbindacustomizedalarm,andchangethealarmseverity.
AcustomizedalarmconfiguredontheNodeBoreNodeBmustbeaddedandboundtotheM2000sothatthealarmconsolecan
identifyandreportthealarm.
1.LogintotheM2000client.
2.ChooseMonitor>AlarmSetting>NEAlarmSetting.TheNEAlarmSettingwindowisdisplayed.
3.ChooseUserDefinedAlarm>AlarmDefinition.TheAlarmDefinitiontabpageisdisplayed.
Fordetails,seesection"FaultManagement>FaultMonitoring>DefininganNEAlarm"intheM2000documentation.
Ifyouconfiguretheoutputalarmport,youdonotneedtobindthealarmtotheM2000.
End

4.4.7Commissioning
N/A

4.4.8ActivationVerification
Toverifythemonitoringfunction,performthefollowingsteps:
Step1RunthefollowingMMLcommandstocheckwhetherthePMU,FMU,TCU,andEMUboardsareworkingproperly:
DSPPMU
DSPFMU
DSPTCU
DSPCCU
DSPEMU

Ifthesystemreturnsanycommandoutputforaboard,theboardisworkingproperly.Whenalltheboardsareworkingproperly,
proceedtoStep2.
Step2PerformtheoperationsdescribedinTable426andcheckwhetherambientalarmsarecorrectlyreported.Ifalarmscannotbe
reported,checkhardwareconnectionsandsoftwareconfigurations.
Table426Verifyingmonitoringalarms
AlarmID

AlarmName

AlarmTriggeringMethod

Remarks

25652

Cabinet
Temperature
Unacceptable

Settheupperlimitofthecabinet
temperaturealarmTUTHD5C
lowerthantheambient
temperatureorsetthelowerlimit
ofTLTHD5Chigherthanthe
ambienttemperature,andwait
morethan10s.
Settheprecedingparameters
onlywhenthePMU,TCU,orFMU
isconfigured.Selectthe
configurationobjectoftheboard
towhichthesensorisconnected.

Thisalarmisreportedonly
whenthetemperaturesensoris
configuredbydefaultoris
installedinthecabinet.
Thetemperaturesensorisnot
configuredbydefaultinthe
BTS3900,BTS3900L,or
BTS3900Ccabinet.
Thetemperaturesensoris
configuredbydefaultinthe
BTS3900A(withRFC),
DBS3900(withRFC),and
BTS3900ALcabinets.

25672

BurglarAlarm

Openthecabinetdoorandwait
morethan10s.

Thisalarmisreportedonly
whenthedoorstatussensoris
configuredbydefaultoris
installedinthecabinet.
Thedoorstatussensorisnot
configuredbydefaultinthe
BTS3900,BTS3900L,DBS3900
(withOMBorIMB),or
BTS3900Ccabinet.
Thedoorstatussensoris
configuredbydefaultinthe
BTS3900A,DBS3900(with
APM30HorTMC),and
BTS3900ALcabinets.

25654

Battery
Temperature
Unacceptable

Inahightemperaturescenario:
Settheupperlimitofthebattery
temperaturealarmTUTHDlower
thantheambienttemperatureor
settheambienttemperature
higherthantheupperlimit,and
waitmorethan2s.
Inalowtemperaturescenario:Set
thelowerlimitofthebattery
temperaturealarmTLTHDhigher
thantheambienttemperatureor
settheambienttemperaturelower
thanthelowerlimit,andwaitmore
than2s.
Settheprecedingparameters
onlywhenthebatteryis
configured.Fordetails,seePower
ManagementFeatureParameter
Description.

Thisalarmisreportedonly
whenthebatteryisconfigured
inthecabinet.

25650

Ambient
Temperature
Unacceptable

Inahightemperaturescenario:
Settheupperlimitoftheambient
temperaturealarmTUTHDlower
thantheambienttemperatureor
settheambienttemperature
higherthantheupperlimit,and
waitmorethan2s.
Inalowtemperaturescenario:Set
thelowerlimitoftheambient
temperaturealarmTLTHDhigher

Thisalarmisreportedonly
whentheEMUorEMUAis
configured.

thantheambienttemperatureor
settheambienttemperaturelower
thanthelowerlimit,andwaitmore
than2s.
Settheprecedingparameters
onlywhentheEMUisconfigured.
25651

Ambient
Humidity
Unacceptable

Inahighhumidityscenario:Set
theupperlimitoftheambient
humidityalarmHUTHDlowerthan
theambienthumidityorsetthe
ambienthumidityhigherthanthe
upperlimit,andwaitmorethan
2s.
Inalowhumidityscenario:Setthe
lowerlimitoftheambienthumidity
alarmHLTHDhigherthanthe
ambienthumidityorsetthe
ambienthumiditylowerthanthe
lowerlimit,andwaitmorethan2s.
Settheprecedingparameters
onlywhentheEMUisconfigured.

25653

Cabinet
Humidity
Unacceptable

Settheupperlimitofthecabinet
humidityalarmHUTHD10%RH
lowerthanthecabinethumidityor
setthelowerlimitofHLTHD10%
RHhigherthanthecabinet
humidity,andwaitmorethan10s.
Settheprecedingparameters
onlywhentheEMUisconfigured.

25670

WaterAlarm

Performanyofthefollowing
operations:
Placethewatersensorinwater
formorethan10s.
Disconnectthewatersensor.

25671

SmokeAlarm

Performanyofthefollowing
operations:
Generatesmokearoundthe
smokesensorformorethan
15s.
Disconnectthesmokesensor
andsetthesmokesensoralarm
tohighvoltage.

Step3IfacustomizedBooleanalarmdeviceisconnected,checkwhetheranalarmisreportedbysettingthealarmdevicetohighlevel
orlowlevel.Verifythatthealarmsarecorrectlyconfigured.
End

4.4.9Reconfiguration
Whenyoureconfigureparametersformonitoringdevices,collectinformationaboutparameterstobereconfiguredbasedononsite
hardwareconfigurationandenvironmentmonitoringrequirements.Fordetails,seesection4.4.3"DataPreparation."
RuntheMODPMUcommandtoreconfigurePMUparameters.
RuntheMODFMUcommandtoreconfigureFMUparameters.
RuntheMODTCUcommandtoreconfigureTCUparameters.
RuntheMODCCUcommandtoreconfigureCCUparameters.
RuntheMODEMUcommandtoreconfigureEMUparameters.

4.4.10Deactivation
N/A

4.5Optimization
N/A

4.6Troubleshooting
Table427listscommonalarmsrelatedtomonitoringdevicefaultsandTable426listscommonalarmsrelatedtoenvironment
exceptions.Fordetailsabouthowtoclearthesealarms,seeNodeBAlarmReferenceandeNodeBAlarmReference.

Table427Commonalarmsrelatedtomonitoringdevicefaults
AlarmID

AlarmName

ALM25600

MonitoringDeviceMaintenanceLinkFailure

ALM25601

MonitoringDeviceHardwareFault

ALM25602

SensorFailure

ALM25620

MonitoringDevicePowerSupplyProblem

5EngineeringGuidelines(GSM)
5.1WhentoUseMonitoringManagement
ItisrecommendedthatthemonitoringmanagementfeaturebeenabledwhenyouintendtomonitorpowerandfanunitsinaBTS.If
auxiliarydevicescapableofmonitoringfunctionsareconfiguredforaBTS,itisrecommendedthatthecustomizedalarmfunctionbe
enabled.

5.2InformationtoBeCollected
Softwareconfigurationvariesaccordingtohardwareconfigurationandcableconnectionsbetweenmonitoringboards.Beforeyou
configuresoftware,collectinformationaboutthefollowingdevicesbasedonthehardwareconfigurationorhardwareconfigurationplan:
Plannedorinstalledboardsrelatedtomonitoring

Table41liststheboardsthatneedtobeconfiguredfordifferenttypesofBTSsindifferentscenarios.IftheGATMboardisconfigured
foraBTS,theboardmustalsobeconfiguredforotherscenarioslistedinTable41.ThelogicalnameofGATMisGATM.Thelogical
namesinTable41arethenamesofdevicesdisplayedontheconfigurationtoolinterface.
Devicesthatmanageboards

BoardmanagersincludeBBU,CCU,andRRU.Collecttheirrespectiveinformationaccordingtothehardwareconnectionsonsite.
ThelogicalnamesinTable41arethenamesofdevicesdisplayedontheconfigurationtoolinterface.

5.3NetworkPlanning
RFPlanning
N/A

NetworkTopology
N/A

HardwarePlanning
TheEMUorEMUAmayberequiredforconfiguringcustomizedalarmsonBTSs.Table42describesthehardwareplanningfor
customizedalarmconfiguration.ThehardwareplanningforvariousBTSstypesisthesameasthatforNodeBsandeNodeBs.

5.4FeatureDeployment
5.4.1DeploymentProcedure
Thereisnofixedsequenceforconfiguringthemonitoringmanagementfeature.

5.4.2DeploymentRequirements
None

5.4.3DataPreparation
GenericData
None

ScenariospecificData
Thefollowingscenarioscanbeusedtogether.Iftheyareusedtogether,dataforallthesescenariosmustbeprepared.

Scenario1:ConfiguringthePMU
FortheparametersettingsforthePMU,seePowerManagementFeatureParameterDescription.

Scenario2:ConfiguringtheFMU
Table51describestheparametersettingsfortheFMU.
Table51ParametersettingsfortheFMU
Parameter
Name

ParameterID

SettingDescription
Thisparameterspecifiesthenumberofthe

Source

CabinetNo.

CN

cabinethousingtheFMU.
IfthenumberoftheRFChousingtheFMUis1,
setthisparameterto1.

Network
plan

Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberofthe
subrackhousingtheFMU.
SubrackNo.

SRN

SlotNo.

SN

Setthisparameterto11or12.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberoftheslot
housingtheFMU.
Setthisparametertothedefaultvalue0.

BoardType
Board
Parameter
Configuration
Enabled

BT

CFGFLAG

SetthisparametertoFMU.
ThisparameterspecifieswhetherFMU
configurationisallowed.
SetthisparametertoYes.

Network
plan

Network
plan
Network
plan
Network
plan

Thisparameterspecifieswhethertoenable
smarttemperaturecontrol.
WhenthisparameterissettoENABLED,the
FMUadjuststhefanspeedaccordingtothe
temperaturecontrolparametersdeliveredby
theBBU.Inthismode,thefannoiseislow.
WhenthisparameterissettoDISABLED,the
FMUautomaticallyadjustsfanspeed
accordingtotheambienttemperature.Inthis
mode,thefannoiseishigh.
ThisparametercanbesettoENABLEDor
DISABLED.

Smart
Temperature
Control

STC

Network
plan

ENABLEDisrecommended.
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfora
Booleanalarmisselected,theBooleanalarm
cannotbereported.

Special
Boolean
AlarmFlag

Special
AlarmValid
Level
Configuration

Manager
CabinetNo.

Manager
SubrackNo.

SBAF

Valuerange:SMDISABLE(Smog{LowLevel}),
WIDISABLE(WaterImmersed{LowLevel}),
GMDISABLE(GateMagnetism{LowLevel}),
ARRESTER1(LightningArrester1{LowLevel}),
and
ARRESTER2(LightningArrester2{LowLevel})
ItisrecommendedthattheFMUnotbe
connectedtoexternalsensorsandallsensors
bedisabled.Ifyouwanttousethesensors,
contactHuaweitechnicalsupport.
Retainthedefaultsettings,whichmeanthatall
sensorsaredisabled.
Thisparameterspecifiesthelevelspecifications
forthededicatedBooleanalarm.Therearetwo
specifications:highlevelandlowlevelalarms.

SPECIALSWITCHERLEVEL

MCN

MSRN

ItisrecommendedthatthededicatedBoolean
alarmfunctionbedisabledontheFMU.When
SBAFisdisabled,thisparameterdoesnot
needtobeconfigured.
Thisparameterspecifiesthecabinetnumberof
theTMU,CCU,orRXU.TMU,CCU,andRXU
arethelogicalnamesoftheGTMU,CCU,and
RRUrespectively.
Duringsiteconfiguration,theFMUisnot
directlyconnectedtotheRXU.Setthis
parametertothecabinetnumberoftheTMUor
CCUthatconnectstotheFMU.
Thisparameterspecifiesthesubracknumberof
theTMU,CCU,orRXU.TMU,CCU,andRXU
arethelogicalnamesoftheGTMU,CCU,and
RRUrespectively.
Duringsiteconfiguration,theFMUisnot

Network
plan

Network
plan

Network
plan

Network
plan

directlyconnectedtotheRXU.Setthis
parametertothesubracknumberoftheTMU
orCCUthatconnectstotheFMU.
Thisparameterspecifiesthenumberofthe
serialportonthemanagertowhichtheFMUis
connected.
Manager
PortNo.

IftheFMUisconnectedtotheBBU:
UPEU/UEIU(MON1):1

MPN

Network
plan

UPEU/UEIU(MON0):0

IftheFMUisconnectedtotheCCU,itmustbe
connectedtoportD_COM1.Setthisparameterto
1.
Thisparameterspecifiesthecommunication
addressoftheFMU.AmaximumoftwoFMUs
canbeconfiguredonanRS485bus.
Address

ADDR

Setthisparameterasfollows:
UpperlevelFMUintwocascadedFMUs:14

Network
plan

LowerlevelFMUintwocascadedFMUs:15

ThisparameterspecifiestheFMUAboardtype.
FMUBoard
Type

SetthisparametertoOUTDOORwhenthe
FMUAisinstalledinanoutdoorcabinet.

FMUTYPE

SetthisparametertoINDOORwhenthe
FMUAisinstalledinanindoorcabinet.

Network
plan

Temperature
Control
Mode

Thisparameterspecifieswhichmodeisusedto
adjustthefanspeed.SetthisparametertoDefault.

TCMODE

Thedefaultmodeachievesatradeoffamong
powerconsumption,noise,andtemperature
control.Itappliestomostscenarios.

Network
Plan

Scenario3:ConfiguringtheTCU
Table52describestheparametersettingsfortheTCU.Parametersthatarenotlistedinthetabledonotneedtobeconfiguredforthe
3900seriesbasestations.
Table52ParametersettingsfortheTCU
ParameterName

ParameterID

SettingDescription

Source

Thisparameterspecifiesthenumberof
thecabinethousingtheTCU.
CabinetNo.

CN

IfthenumberoftheRFChousingthe
TCUis1,setthisparameterto1.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.

Network
plan

Thisparameterspecifiesthenumberof
thesubrackhousingtheTCU.
SubrackNo.

SRN

Setthisparameterto8or14.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.

Network
plan

Thisparameterspecifiesthenumberof
theslothousingtheTCU.
IftheTCUisinstalledintheBTS3900AL
AC,BTS3900ALDC,IBBS700D,or
IBBS700Tcabinet,setthisparameteras
follows:
SettheslotnumberoftheCMUFto0.

SettheslotnumberofHAU0to1.

SettheslotnumberofHAU1to2.

SlotNo.

SN

IftheTCUisinstalledintheTP48600A
cabinet,setthisparameterasfollows:
SettheslotnumberoftheCMUFfor
cabinettemperaturecontrolto0.
SettheslotnumberoftheCMUFfor
batterycabinettemperaturecontrolto
1.
SettheslotnumberofHAU0to2.

Network
plan

SettheslotnumberofHAU1to3.

IftheTCUisinstalledonothercabinet,
setthisparameterto0.
BoardType

BT

BoardParameter
Configuration
Enabled

CFGFLAG

Temperature
AlarmUpper
Threshold

Temperature
AlarmLower
Threshold

SetthisparametertoTCU.
ThisparameterspecifieswhetherTCU
configurationisallowed.
SetthisparametertoYes.

TUTHD

Thisparameterspecifiestheupper
temperaturelimitforthecabinet.Ifthe
temperatureexceedstheupperlimit,the
alarmALM25652CabinetTemperature
Unacceptableisreported.

Network
plan
Network
plan

Network
plan

Itisrecommendedthatthisparameter
besetto50fortheTCUintheBBCand
68fortheTCUinothercabinets.

TLTHD

Thisparameterspecifiesthelower
temperaturelimitforthecabinet.Ifthe
temperatureexceedsthelowerlimit,the
alarmALM25652CabinetTemperature
Unacceptableisreported.

Network
plan

Thedefaultvalueisrecommendedfor
thisparameter.

ManagerCabinet
No.

ManagerSubrack
No.

MCN

Thisparameterspecifiesthecabinet
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.

Network
plan

MSRN

Thisparameterspecifiesthesubrack
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.

Network
plan

Thisparameterspecifiesthenumberof
theserialportonthemanagertowhich
theTCUisconnected.
IftheTCUisconnectedtotheBBU:
UPEU/UEIU(MON1):1
UPEU/UEIU(MON0):0

ManagerPortNo.

MPN

IftheTCUisconnectedtotheCCU:
CMUFispermanentlyconnectedto

Network
plan

portD_COM0,setthisparameterto0
FAU0andFAU1arepermanently

connectedtoportD_COM3,setthis
parameterto3
IftheTCUisconnectedtotheRRU,
setthisparameterto0.

IntheAPM30HorTMC11Hcabinet,a
maximumoftwoTCUscanbe
configuredonanRS485bus.
Setthisparameterasfollows:
UpperlevelTCUintwocascaded
TCUs:7
LowerlevelTCUintwocascaded
TCUs:6
IntheIBBS200D/IBBS200Tcabinet,a
maximumoffourTCUscanbe
configuredonanRS485bus.
Setthisparameterasfollows:
IftheupperlevelTCUismanagedby
thePMUwhosecommunication
addressis3,setthisparameterto23.
IfthelowerlevelTCUismanagedby
thisPMU,setthisparameterto24.

Address

ADDR

IftheupperlevelTCUismanagedby
thePMUwhosecommunication
addressis4,setthisparameterto25.
IfthelowerlevelTCUismanagedby
thisPMU,setthisparameterto26.

Network
plan

IftheHAUsareinstalled,amaximumof
twoTCUscanbeconfiguredonan
RS485bus.
Setthisparameterasfollows:
UpperlevelTCUintwocascaded
TCUs:28

LowerlevelTCUintwocascaded
TCUs:29

AlarmParameter
Configuration
Enabled

Thisparameterspecifieswhetherto
enableSBAF.
ALMPARACFGFLAG

Itisrecommendedthatthisparameter
besettoNo,whichmeansthatSBAFis
disabled.

Network
plan

Thisparameterspecifieswhetherto
reportadedicatedBooleanalarm.Ifthe
shieldflagforaBooleanalarmis
selected,theBooleanalarmcannotbe
reported.
SpecialBoolean
AlarmFlag

Valuerange:WS_DISABLE(Water
ImmersedSensorDisabled)and
SS_DISABLE(SmogSensorDisabled).
ItisrecommendedthattheTCUnotbe
connectedtoexternalsensorsandall
sensorsbedisabled.Ifyouwanttouse
thesensors,contactHuaweitechnical
support.

SBAF

Network
plan

Retainthedefaultsettings,whichmean
thatallsensorsaredisabled.

Scenario4:ConfiguringtheCCU
Table53describestheparametersettingsfortheCCU.
Table53ParametersettingsfortheCCU
ParameterName

ParameterID

SettingDescription

Source

Thisparameterspecifiesthenumberofthe
cabinethousingtheCCU.
CabinetNo.

CN

SubrackNo.

SRN

IfthenumberoftheBTS3900ALcabinet
housingtheCCUis0,setthisparameterto
0.
Fordetails,seeBaseStationCabinetsand
Subracks(IncludingtheBBUSubrack)
Configuration.
Thisparameterspecifiesthenumberofthe
subrackhousingtheCCU.
Setthisparametertothedefaultvalue15.

SlotNo.

SN

Thisparameterspecifiesthenumberofthe
slothousingtheCCU.
Setthisparametertothedefaultvalue0.

BoardType

BT

BoardParameter
Configuration
Enabled

CFGFLAG

ManagerCabinet
No.

SetthisparametertoCCU.
ThisparameterspecifieswhetherCCU
configurationisallowed.
SetthisparametertoYes.

MCN

Thisparameterspecifiesthecabinetnumber
oftheTMU,CCU,orRXU.TMU,CCU,and
RXUarethelogicalnamesoftheGTMU,
CCU,andRRUrespectively.

Network
plan

Network
plan
Network
plan
Network
plan
Network
plan

Network
plan

TheCCUcanonlybemanagedbytheTMU.

ManagerSubrack
No.

MSRN

Thisparameterspecifiesthesubracknumber
oftheTMU,CCU,orRXU.TMU,CCU,and
RXUarethelogicalnamesoftheGTMU,
CCU,andRRUrespectively.

Network
plan

TheCCUcanonlybemanagedbytheTMU.
Thisparameterspecifiesthenumberofthe
serialportonthemanagertowhichtheCCU
isconnected.
ManagerPortNo.

MPN

Network

TheCCUmustbeconnectedtoportMON0
ontheBBU.Therefore,thisparametermust
besetto0.
ThisparameterspecifieswhethertheCCU
isdirectlyconnectedtoitsmanager.Ifthe
CCUisdirectlyconnectedtoitsmanager,
setthisparametertoYES.

plan

DirectConnectFlag

DCF

IftheCCUisconnectedtoitsmanagerover
acascadingCCU,setthisparameterto
NO.

Network
plan

Thisparameterspecifiestheinserted
positionoftheCCUonaCCUcascadedlink.
CascadeNo.

Connected
Standard

CCN

CS

Setthisparameterto1fortheleftmostCCU
onthelink(theCCUwhoseportFE_Lisnot
connected).Setthisparametertoaninteger
inascendingorderfortheotherCCUsonthe
link.
Thisparameterspecifiesthenetwork
technologytypeoftheBBUthatisdirectly
connectedtotheCCU.Setthisparameterto
GSM,UMTS,orLTE.

Network
plan

Network
plan

TheparameterisvalidonlywhentheDCFis
settoYes.
Thisparameterspecifieswhethertoreporta
dedicatedBooleanalarm.Iftheshieldflagfor
aBooleanalarmisselected,theBoolean
alarmcannotbereported.

SpecialBoolean
AlarmFlag

SBAF

Valuerange:WS_DISABLE(Water
ImmersedSensorDisabled)and
SS_DISABLE(SmogSensorDisabled).
ItisrecommendedthattheCCUnotbe
connectedtoexternalsensorsandall
sensorsbedisabled.Ifyouwanttousethe
sensors,contactHuaweitechnicalsupport.

Network
plan

Retainthedefaultsettings,whichmeanthat
thewatersensorandsmokesensorare
disabled.

Scenario5:ConfiguringtheGATM
Table54describestheparametersettingsfortheGATM.
Table54ParametersettingsfortheGATM
ParameterName

ParameterID

SettingDescription

Source

Thisparameterspecifiesthenumberof
thecabinethousingtheGATM.
CabinetNo.

CN

IfthenumberoftheAPM30Hhousingthe
GATMis1,setthisparameterto1.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.

SubrackNo.

SRN

SlotNo.

SN

Thisparameterspecifiesthenumberof
thesubrackhousingtheGATM.Itcanbe
setto40or59.
Fordetails,seeBaseStationCabinets
andSubracks(IncludingtheBBU
Subrack)Configuration.
Thisparameterspecifiesthenumberof
theslothousingtheGATM.
Setthisparametertothedefaultvalue0.

BoardType

BT

BoardParameter
Configuration
Enabled

CFGFLAG

SetthisparametertoGATM.
ThisparameterspecifieswhetherGATM
configurationisallowed.
SetthisparametertoYes.
Thisparameterspecifieswhetherto
providepowersuppliestotowermounted
amplifiers(TMAs)ofbranches0through

Network
plan

Network
plan

Network
plan
Network
plan
Network
plan

ANT0ALDPower
Switch~ANT5ALD
PowerSwitch

AMPC0~AMPC5

5.
IfabranchisconnectedtoaTMA,set
thisparametertoON.

Network
plan

IfabranchisnotconnectedtoaTMA,
setthisparametertoOFF.

Thisparameterspecifiesthemodefor
reportingthefeedingcurrentalarmsof
TMAsofbranches0through5.Whenthe
feedingcurrentexceedsthethreshold,an
alarmisreported.
Valuerange:MODE1,MODE2,and
MODE3
MODE1:Onlymajoralarmsare
reported.

MODE2:Warningsandmajoralarms
arereported.Inthismode,both
warningsandmajoralarmsare
reportedasfixedvaluecurrent.

ANT0Alarm
Mode~ANT5
AlarmMode

MODE0~MODE5

Network
plan

MODE3:Warningsandmajoralarms
arereported.Inthismode,warnings
arereportedasperiodicpulsecurrent,
andmajoralarmsarereportedasfixed
valuecurrent.Periodicpulsecurrentis
reportedwhenthealarmreporting
requirementismetwithinapreset
period.Comparedwithfixedvalue
current,periodicpulsecurrentiseasily
reported.

Itisrecommendedthatthisparameterbe
settoMODE1.
ANT0ALDOver
CriticalAlarm
Threshold(mA)~
ANT5ALDOver
CriticalAlarm
Threshold(mA)

MAJORALMUP0~
MAJORALMUP5

Thisparameterspecifiesthethresholdfor
reportingthecriticalalarmrelatedtothe
feedingcurrentoftheTMA.
WhenthefeedingcurrentoftheTMA
onsiteexceedsthisthreshold,thealarm
ALM28002GATMALDCurrentOutof
Rangeisreported.

Network
plan

MINORALMUP0~
MINORALMUP5

Thisparameterspecifiesthethresholdfor
reportingthewarningrelatedtothe
feedingcurrentoftheTMA.Whenthe
feedingcurrentoftheTMAonsite
exceedsthisthreshold,thealarmALM
28002GATMALDCurrentOutofRange
isreported.

Network
plan

ANT0ALDLow
CurrentAlarm
Threshold(mA)~
ANT5ALDLow
CurrentAlarm
Threshold(mA)

ALMD0~ALMD5

Thisparameterspecifiesthethresholdfor
reportingthewarningrelatedtothe
feedingcurrentoftheTMA.Whenthe
feedingcurrentoftheTMAonsite
exceedsthisthreshold,thealarmALM
28002GATMALDCurrentOutofRange
isreported.

Network
plan

ManagerCabinet
No.

MCN

Thisparameterspecifiesthecabinet
numberoftheTMU,CCU,orRXU.TMU,
CCU,andRXUarethelogicalnamesof
theGTMU,CCU,andRRUrespectively.

Network
plan

MSRN

Thisparameterspecifiesthesubrack
numberoftheTMU,CCU,orRXU.TMU,
CCU,andRXUarethelogicalnamesof
theGTMU,CCU,andRRUrespectively.

Network
plan

ANT0ALDOver
WarningAlarm
Threshold(mA)~
ANT5ALDOver
WarningAlarm
Threshold(mA)

ManagerSubrack
No.

Thisparameterspecifiesthenumberof
theserialportonthemanagertowhich
theGATMisconnected.
Setthisparameterasfollows:

ManagerPortNo.

MPN

IftheGATMisconnectedtotheBBU:
GATM0isconnectedtoMON0onthe
UPEU.Setthisparameterto0.
GATM1isconnectedtoMON1onthe
UPEU.Setthisparameterto1.
IftheGATMisconnectedtoCCU:
GATM0ispermanentlyconnectedto
portD_COM5.Setthisparameterto5.

Network
plan

GATM1ispermanentlyconnectedto

portD_COM6.Setthisparameterto6.
Address

ADDR

Thisparameterspecifiesthe
communicationaddressoftheGATM.
Setthisparameterto22.

Network
plan

Scenario6:ConfiguringCustomizedAlarms
Topreparedataforcustomizedalarmconfiguration,performthefollowingsteps:
Step1PrepareEMUconfigurationdata.
Beforedatapreparation,checkwhethertheEMUneedstobeconfiguredbyreferringtoTable42.IftheEMUisrequired,
prepareEMUconfigurationdatabyreferringtoTable55.Otherwise,skipthisstep.
Step2Prepareconfigurationdataofthealarmsignalinputandoutputportsbasedontheinputandoutputrequirementsofcustomized
alarms.
PrepareconfigurationdataoftheenvironmentalalarmsignalinputportALMPORTbyreferringtoTable56.
PrepareconfigurationdataoftheenvironmentalalarmsignaloutputportOUTPORTbyreferringtoTable57.

End
Table55ParametersettingsfortheEMU
Parameter
Name

ParameterID

SettingDescription
Thisparameterspecifiesthenumber
ofthecabinethousingtheEMU.

CabinetNo.

SubrackNo.

CN

SRN

SlotNo.

SN

BoardType

BT

Board
Parameter
Configuration
Enabled

CFGFLAG

IfthenumberoftheBTS3900
cabinethousingtheEMUis0,set
thisparameterto0.
Thisparameterspecifiesthenumber
ofthesubrackhousingtheEMU.
Setthisparametertothedefault
value.
Thisparameterspecifiesthenumber
oftheslothousingtheEMU.
Setthisparametertothedefault
value.
SetthisparametertoEMU.
Thisparameterspecifieswhether
EMUconfigurationisallowed.
SetthisparametertoYes.

Source

Network
plan

Network
plan

Network
plan
Network
plan
Network
plan

Thisparameterspecifieswhetherto
reportadedicatedBooleanalarm.If
theshieldflagforaBooleanalarmis
selected,theBooleanalarmcannot
bereported.

SpecialAnalog
AlarmFlag

SAAF

Valuerange:48V_DISABLE(48
VoltageDisabled),
RES0(PreservedParameter0),
RES1(PreservedParameter1),
RES2(PreservedParameter2),
TS_DISABLE(TemperatureSensor
Disabled),HS_DISABLE(Humidity
SensorDisabled),RES3(Preserved
Parameter3),andRES4(Preserved
Parameter4)
Setthisparameterasfollows:
The48Valarmisusedtocheck

whethertheinputvoltageforthe
cabinetisnormal.Whentheinput
voltageforthecabinetis48V,itis
recommendedthat48V_DISABLE
becleared.
RES0,RES1,andRES2are

parametersreservedbyHuawei
andtheyareselected.
Setthesensorsaccordingtothe

typesofsensorsconnectedtothe

Network
plan

EMUorEMUA.

SpecialBoolean
AlarmFlag

SBAF

Thisparameterspecifieswhetherto
reportadedicatedBooleanalarm.If
theshieldflagforaBooleanalarmis
selected,theBooleanalarmcannot
bereported.
Valuerange:WILOW(Water
Immersed{LowLevel}),
SMLOW(Smog{LowLevel}),
IMLOW(Infrared{LowLevel}),and
GMLOW(GateMagnetism{Low
Level})

Network
plan

Setthisparameteraccordingtothe
typeofthesensororexternaldevice
connectedtotheEMU.

SpecialAlarm
SwitchValid
Vol.Level

Manager
CabinetNo.

Manager
SubrackNo.

SPECIALSWITCHERLEVEL

Thisparameterspecifiesthelevel
specificationsforthededicated
Booleanalarm.Therearetwo
specifications:HighLevelandLow
Level.

Network
plan

Setthisparameteraccordingtothe
typeofthesensororexternaldevice
connectedtotheEMU.

MCN

Thisparameterspecifiesthecabinet
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.

Network
plan

MSRN

Thisparameterspecifiesthesubrack
numberoftheTMU,CCU,orRXU.
TMU,CCU,andRXUarethelogical
namesoftheGTMU,CCU,andRRU
respectively.

Network
plan

Thisparameterspecifiesthenumber
oftheserialportonthemanagerto
whichtheEMUisconnected.Setthis
parameterasfollows:
IftheTCUisconnectedtotheBBU:
ManagerPort
No.

MPN

UPEU/UEIU(MON1):1
UPEU/UEIU(MON0):0
IftheTCUisconnectedtotheCCU,
itmustbeconnectedtoport
D_COM3.Setthisparameterto3.

Network
plan

IftheTCUisconnectedtotheRRU,
setthisparameterto0.

Address

ADDR

Thisparameterspecifiesthe
communicationaddressoftheEMU.
Setthisparameterto2.

HumidityAlarm
Lower
Threshold

HumidityAlarm
Upper
Threshold

TLTHD

Thisparameterspecifiesthelower
ambienttemperaturelimit.Ifthe
ambienttemperatureexceedsthe
lowerlimit,theBTSreportsthealarm
ALM25650AmbientTemperature
Unacceptable.
Thisparameterneedstobe
configuredonlywhenTS_DISABLE
inSAAFiscleared.
Thedefaultvalueisrecommended
forthisparameter.

TUTHD

Thisparameterspecifiestheupper
ambienttemperaturelimit.Ifthe
ambienttemperatureexceedsthe
upperlimit,theNodeBoreNodeB
reportsthealarmALM25650
AmbientTemperatureUnacceptable.
Thisparameterneedstobe
configuredonlywhenTS_DISABLE
inSAAFiscleared.
Thedefaultvalueisrecommended
forthisparameter.
Thisparameterspecifiesthelower

Network
plan

Network
plan

Network
plan

Temperature
AlarmLower
Threshold

ambienthumiditylimit.Iftheambient
humidityexceedsthelowerlimit,the
alarmALM25651AmbientHumidity
Unacceptableisreported.
Thisparameterneedstobe
configuredonlywhenHS_DISABLE
inSAAFiscleared.

HLTHD

Network
plan

Thedefaultvalueisrecommended
forthisparameter.

Temperature
AlarmUpper
Threshold

Thisparameterspecifiestheupper
ambienthumiditylimit.Iftheambient
humidityexceedstheupperlimit,the
alarmALM25651AmbientHumidity
Unacceptableisreported.
Thisparameterneedstobe
configuredonlywhenHS_DISABLE
inSAAFiscleared.

HUTHD

Network
plan

Thedefaultvalueisrecommended
forthisparameter.

Table56ParametersettingsfortheALMPORT
ParameterName

ParameterID

SettingDescription

Source

CabinetNo.

CN

Thisparameterspecifiesthecabinetnumber
oftheboardwheretheALMPORTportis
located.

Network
plan

SubrackNo.

SRN

Thisparameterspecifiesthesubracknumber
oftheboardwheretheALMPORTportis
located.

Network
plan

SlotNo.

SN

Thisparameterspecifiestheslotnumberof
theboardwheretheALMPORTportis
located.

Network
plan

Thisparameterspecifiesthenumbersofthe
alarmportsoneachmonitoringboardas
follows:
PortNo.

PN

UPEU/UEIU:0to7(forBooleanalarms)

RRU:0to3(forBooleanalarms)

Network
plan

EMU/EMUA:0to31(forBooleanalarms)

EMU/EMUA:32to35(foranalogalarms)

Ifacustomizedalarminputisrequired,the
switchmustbeturnedon.Thisparameter
specifiestheswitchoftheportandcanbeset
asfollows:
OFF(Off):indicatesthattheportisdisabled
andalarmscannotbedetected.Thisisthe
defaultvalueforthisparameter.
ON(On):indicatesthattheportisenabled
andalarmscanbereportedthroughthe
portaccordingtothecustomizedalarmIDs.
Inaddition,thealarmvoltagelevelfor
Booleanalarmsorthealarmupper/lower
limitcanbesetinthisparameter.

Switch

AlarmID.

SW

AID

ThisparameterspecifiesthealarmID
pertainingtothealarmport.Ifanalarmis
detectedthroughtheport,thevalueofthis
parameterisusedasthealarmIDandis
reportedwiththealarm.Thevaluerangeof
thisparameteris65033to65233.

Network
plan

Network
plan

Thealarmname,alarmseverity,andOSS
typecorrespondingtothealarmIDare
configuredontheM2000client.
Thisparameterspecifiesthetypeofanalarm
port.SetthisparametertoBOOLorVALUE.
PortType

PT

Ananalogport,providedbytheEMUor
EMUA,monitorstheexternalenvironment.
Adigitalport,providedbytheUPEU,UEIU,
RRU,EMU,orEMUA,monitorstheexternal
environmentwithBooleanordiscretevalues.
ThisparameterisvalidonlywhenPTissetto

Network
plan

AlarmVOL.

AVOL

BOOL.
Thisparameterspecifieswhetherthesensor
sendstheportahighlevelorlowlevelalarm.
Setthisparameterbasedonalarmcable
connection.Fordetailsaboutthepin
assignmentforthewiresofalarmcables,see:
Section"BBUAlarmCable"inthebase

Network
plan

stationspecifichardwaredescription.
Section"RRUAlarmCable"intheRRU

specifichardwaredescription.
Section"RS485SerialPort"inEMUUser
GuideandEMUAUserGuide.

Thisparameterspecifiesthealarmupper
limit.Iftheenvironmentmeasurementvalueis
greaterthanthealarmupperlimitofthe
sensor,thealarmisreported.
UpperLimit

UL

Environmentmeasurementvalue=
Measurementlowerlimit+(Measurement
upperlimitMeasurementlowerlimit)x
(ObservedcurrentorvoltageOutputlower
limit)/(OutputupperlimitOutputlowerlimit).

Network
plan

ULmustbesmallerthanorequaltoSMUL
andgreaterthanLL.
Thisparameterspecifiesthealarmlowerlimit.
Iftheenvironmentmeasurementvalueis
smallerthanthealarmlowerlimitofthe
sensor,thealarmisreported.
LowerLimit

LL

Environmentmeasurementvalue=
Measurementlowerlimit+(Measurement
upperlimitMeasurementlowerlimit)x
(ObservedcurrentorvoltageOutputlower
limit)/(OutputupperlimitOutputlowerlimit).

Network
plan

LLmustbegreaterthanorequaltoSMLL
andsmallerthanUL.

SensorType

ST

Thisparameterspecifiesthetypeofasensor.
SetthisparametertoVOLTAGEor
CURRENTbasedontheexternalsensor
specifications.

Network
plan

ThisparameterisvalidonlywhenPTissetto
VALUE.
MeasureUpper
LimitOfSensor

SMUL

Thisparameterspecifiesthemeasurement
upperlimitoftheanalogport.Setthis
parameterbasedonthesiteconditions,such
asthetemperatureandhumidity.
SMULmustbegreaterthanorequaltoUL.

Network
plan

SMULmustbegreaterthanSMLL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
MeasureLower
LimitOfSensor

SMLL

Thisparameterspecifiesthemeasurement
lowerlimitoftheanalogport.Setthis
parameterbasedonthesiteconditions,such
asthetemperatureandhumidity.
SMLLmustbesmallerthanorequaltoLL.

Network
plan

SMLLmustbesmallerthanSMUL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
UpperLimitOf
SensorOutput

SOUL

Thisparameterspecifiestheoutputsignal
upperlimitoftheanalogport.Forasensorof
eitherthecurrenttypeorthevoltagetype,set
thisparameterbasedontheexternalsensor
specifications.

Network
plan

SOULmustbegreaterthanSOLL.
ThisparameterisvalidonlywhenPTissetto
VALUE.
LowerLimitOf
SensorOutput

SOLL

Thisparameterspecifiestheoutputsignal
lowerlimitoftheanalogport.Forasensorof
eitherthecurrenttypeorthevoltagetype,set
thisparameterbasedontheexternalsensor
specifications.
SOLLmustbesmallerthanSOUL.

Network
plan


Table57ParametersettingsfortheOUTPORT
Parameter
Name

ParameterID

Refrigeration
Equipment

COLDSET

SettingDescription
Thisparameterspecifieswhethertoenable
arefrigerationdeviceontheBTS.
Setthisparametertochannel0outputof
theEMU.

Heating
Equipment

WARMSET

Thisparameterspecifieswhethertoenable
aheatingdeviceontheBTS.
Setthisparametertochannel1outputof
theEMU.

Dehumidification
Equipment

DRYSET

Thisparameterspecifieswhethertoenable
adehumidifierontheBTS.
Setthisparametertochannel2outputof
theEMU.

Humidification
Equipment

WETSET

Thisparameterspecifieswhethertoenable
ahumidifierontheBTS.
Setthisparametertochannel3outputof
theEMU.

Fire
extinguishing
Equipment

FIRESET

Antitheft
Equipment

DESTEALSET

Thisparameterspecifieswhethertoenable
afireextinguishingdeviceontheBTS.
Setthisparametertochannel4outputof
theEMU.
Thisparameterspecifieswhethertoenable
anantitheftdeviceontheBTS.
Setthisparametertochannel5outputof
theEMU.

Source

Network
plan

Network
plan

Network
plan

Network
plan

Network
plan

Network
plan

ReferenceforConfiguringtheMonitoringFunction
See"ReferenceforConfiguringtheMonitoringFunction"insection4.4.3"DataPreparation."

5.4.4Precautions
N/A

5.4.5HardwareInstallation
Fordetailsabouthardwareinstallation,seesection"InstallingMonitoringSignalCable"inthebasestationspecificinstallationguide.
WhensettingexternalBooleanalarmsbasedonthehighorlowvoltagesettings,seethefollowingsectionstoobtainthepinassignment
forthewiresofalarmcables:
Section"BBUAlarmCable"inthebasestationspecifichardwaredescription.
Section"RRUAlarmCable"intheRRUspecifichardwaredescription.
Section"RS485SerialPort"inEMUUserGuideandEMUAUserGuide.

5.4.6FeatureActivation/InitialConfiguration
Thescenariosforconfiguringmonitoringmanagementcanbeusedtogether.Iftheyareusedtogether,dataforallthesescenarios
mustbeconfigured.Thereisnofixedsequenceforconfiguringthemonitoringmanagementfeature.WhentheEMUorEMUAis
installedforconfiguringcustomizedalarms,configuretheEMU,andthentheALMPORTorOUTPORT.

ConfiguringaSingleBTSontheGUI
ToconfigurethemonitoringfunctionforaBTS,seesection"CreatingaGBTS(TopologyMode,3900SeriesBaseStations)>
ConfiguringGBTSDeviceData(3900SeriesBaseStations)>ConfiguringMonitoringBoards"in3900SeriesBaseStationInitial
Configuration(SRAN7.0)>GBTSInitialConfiguration.

Whenyounavigateinthedocument,locatethecorrectnodebasedonthetypeofthebasestationcontrollerconnectedtothebase
station.

ConfiguringBTSsinBatches
ToconfigurethemonitoringfunctionforBTSsinbatches,customizeatemplatebasedonaconfiguredBTSandthenconfigureBTSsin
batchesbasedonthetemplate.
Fordetails,seesection"CreatingGBTSs(byUsingaSummaryDataFile)"inInitialConfigurationof3900SeriesBaseStations>GBTS
InitialConfiguration.

Whenyounavigateinthedocument,locatethecorrectnodebasedonthetypeofthebasestationcontrollerconnectedtothebase
station.

ConfiguringaSingleBTSUsingMMLCommands
Scenario1:ConfiguringthePMU
FordetailsabouthowtoconfigurethePMU,seePowerManagementFeatureParameterDescription.

Scenario2:ConfiguringtheFMU
Step1RuntheADDBTSBRDcommandtoaddanFMU.
Step2RuntheSETBTSFMUABPcommandtosetFMUparameters.
End

Scenario3:ConfiguringtheTCU
Step1RuntheADDBTSBRDcommandtoaddaTCU.
Step2RuntheSETBTSDHEUBPcommandtosetTCUparameters.
End

Scenario4:ConfiguringtheCCU
Step1RuntheADDBTSBRDcommandtoaddaCCU.
Step2RuntheSETBTSCCUBPcommandtosetCCUparameters.
End

Scenario5:ConfiguringtheGATM
Step1RuntheADDBTSBRDcommandtoaddaGATM.
Step2RuntheSETBTSDATUBPcommandtosetGATMparameters.
End

Scenario6:ConfiguringCustomizedAlarms
Step1(Optional)ConfiguredevicesandparametersrelatedtotheEMU.
1.RuntheADDBTSBRDcommandtoaddanEMU.
2.RuntheSETBTSDEMUBPcommandtosetEMUparameters.
3.IftheEMUisconnectedtoahumidityortemperaturesensor,runtheSETBTSEXDcommandtosetEMUextensionparameters.
Step2RuntheLSTBTSENVALMPORTandLSTBTSOUTPUTcommandstoquerythestatusoftheinputandoutputalarmports,
respectively.
Step3Basedonthequeryresults,runthefollowingcommandstoopentheportthatneedstobeconfiguredasaninputalarmport
andclosetheunusedalarmport.
SETBTSENVALMPORT:tosettheinputalarmport
SETBTSOUTPUT:tosettheoutputalarmport

Step4Addandbindacustomizedalarm,andchangethealarmseverity.
AcustomizedalarmconfiguredontheBTSmustbeaddedandboundtotheM2000sothatthealarmconsolecanidentifyandreport
thealarm.
1.LogintotheM2000client.
2.ChooseMonitor>AlarmSetting>NEAlarmSetting.TheNEAlarmSettingwindowisdisplayed.
3.ChooseUserDefinedAlarm>AlarmDefinition.TheAlarmDefinitiontabpageisdisplayed.
Fordetails,seesection"FaultManagement>FaultMonitoring>DefininganNEAlarm"intheM2000documentation.
Ifyouconfiguretheoutputalarmport,youdonotneedtobindthealarmtotheM2000.
End

5.4.7Commissioning
N/A

5.4.8ActivationVerification
Toverifythemonitoringfunction,performthefollowingsteps:
Step1RuntheDSPBTSBRDcommandtocheckwhetherboardsareworkingproperly.
Ifthesystemreturnsanycommandoutputforaboard,theboardisworkingproperly.Whenalltheboardsareworkingproperly,
proceedtoStep2.

Step2PerformtheoperationsdescribedinTable426andcheckwhetherambientalarmsarecorrectlyreported.Ifalarmscannotbe
reported,checkhardwareconnectionsandsoftwareconfigurations.
Step3IfacustomizedBooleanalarmdeviceisconnected,checkwhetheranalarmisreportedbysettingthealarmdevicetohighlevel
orlowlevel.Verifythatthealarmsarecorrectlyconfigured.
End

5.4.9Reconfiguration
Whenyoureconfigureparametersformonitoringdevices,collectinformationaboutparameterstobereconfiguredbasedononsite
hardwareconfigurationandenvironmentmonitoringrequirements.Fordetails,seesection5.4.3"DataPreparation."
ThecommandsforreconfiguringGBTSmonitoringdevicesarethesameasinitialconfigurationcommands.Fordetails,seesection
5.4.6"FeatureActivation/InitialConfiguration."

5.4.10Deactivation
N/A

5.5Optimization
N/A

5.6Troubleshooting
ThealarmsforBTSsarethesameasthoseforNodeBsandeNodeBs.Fordetails,seeTable427.Fordetailsaboutenvironment
alarms,seeTable426.Ifanalarmisreported,clearthealarmwithrecommendedactionsinalarmreferenceoftheBSC.

6EngineeringGuidelines(DualModes)
ItisrecommendedthattheonesidedconfigurationmodebeappliedtothefollowingtypesofMBTSs:
BTS3900
BTS3900L
BTS3900A
DBS3900(withouttheTP48600A)

TheonesidedconfigurationmodemustapplytothefollowingtypesofMBTSs:
BTS3900AL
DBS3900(withtheTP48600A)

SRAN6.0andlaterversionssupportonesidedconfiguration.VersionsearlierthanSRAN6.0supportonlymodebymodeconfiguration.

IftheprecedingMBTSsareconfiguredmodebymode,thealarmALM26271InterSystemMonitoringDeviceParameterSettings
Conflictisreportedevenwhentheconfigurationonbothmodesisconsistent.
ThefollowingsectionsprovidetheprecautionsforconfiguringMBTSsindifferentmodes.

6.1PrecautionsforOneSidedConfiguration
Thissectiondescribestheconfigurationprecautionsinonesidedconfigurationmode.Forthemethodofdeployingthisfeatureinone
sidedconfigurationmode,seechapter4"EngineeringGuidelines(UMTSorLTE)"andchapter5"EngineeringGuidelines(GSM)."
ThemonitoringdevicesofthesamebasestationmustbeconfiguredforthesameRAT.
Foradualmodebasestation,themonitoringdevicesareconfiguredaccordingtothefollowingpriorityorder:GSM,UMTS,LTE.

Forexample,assumethataBTS3900Ahasthefollowingconfiguration:2APM30Hs+2RFCs+2IBBS200DsorIBBS200Ts,andthe
BTS3900AisusedintheUO+LOscenario.Inthisexample,themonitoringdevicesoftheBTS3900AareconfiguredforUMTS.
Foratriplemodebasestation,themonitoringdevicesareconfiguredaccordingtothemonitoringcableconnectionsinthecabinet.If
themonitoringcablesareconnectedtothedualmodeBBU,configurethemonitoringdevicesaccordingtothefollowingpriorityorder:
GSM,UMTS,LTE.
Forexample,asshowninFigure61,theBTS3900Ahasthefollowingconfiguration:2APM30Hs+2RFCs+2IBBS200Dsor
IBBS200Ts,andtheBTS3900AisusedintheGO+UO+LOscenario.APM30H0housesGUdevices(includingBBUandRFU),and
APM30H1housesLTEdevices.ThemonitoringdevicesandcascadingmonitoringdevicesofAPM30H1areconnectedtoAPM30H
0.TheBBUinAPM30H0performsmonitoringmanagement.Inthisexample,themonitoringdevicesoftheBTS3900Aareconfigured
forGSM.
Figure612APM30Hs+2RFCs+2IBBS200DsorIBBS200Ts


Intheexpansionorevolutionscenario,itisrecommendedthattheRATbeforetheexpansionorevolutionbeconfigured.Then,you

donotneedtoreconstructinventorydevices.Ifthepreviousconditioncannotbemet,configurethemonitoringdevicesaccordingto
thefollowingpriorityorder:GSM,UMTS,LTE.Then,reconstructinventorydevices.
Forexample,ifaGBTS(BTS3900)hasevolvedintoaGUdualmodebasestation,configurethemonitoringdevicesoftheevolved
basestationforGSM.
Intheremotemonitoringscenario,configurethemonitoringdevicesofthesinglemodeRRUfortheRAToftheRRU.Itis

recommendedthatyouconfigurethemonitoringdevicesofthedualmodeRRUaccordingtothefollowingpriorityorder:GSM,
UMTS,LTE.

6.2PrecautionsforModebyModeConfiguration
Thissectiondescribestheconfigurationprecautionsformodebymodeconfiguration.Thereisnofixedsequenceformodebymode
configuration.Fordetails,seechapter4"EngineeringGuidelines(UMTSorLTE)"andchapter5"EngineeringGuidelines(GSM)."
ThemonitoringdevicesconnectedtoBBUsmustbemonitoredbybasestationsusingdifferentRATs.Therefore,whenyouconfigure

thesemonitoringdevices,ensurethatthenumberofphysicaldevicesandconfigurationparametersareconsistentforbasestations
usingdifferentRATs.Fordetailsabouttheparametersthatmustbekeptconsistentoneachmode,seeTable61.
Table61Parametersthatmustbekeptconsistentoneachmode
Object

FMU

TCU

GSMParameter

UMTSandLTEParameters

SettingDescription

Parameter
Name

Parameter
ID

Configuration
Command

Parameter
Name

Parameter
ID

Configuration
Command

Special
Boolean
AlarmFlag

SBAF

SETBTSFMUABP

Special
Boolean
AlarmFlag

SBAF

ADDFMU

Thedefaultvalueis
recommended:
WS_DISABLE(Water
ImmersedSensor
Disabled)and
SS_DISABLE(Smog
SensorDisabled)

Smart
Temperature
Control

STC

SETBTSFMUABP

Smart
Temperature
Control

STC

ADDFMU

ENABLED

SETBTSDHEUBP

Temperature
AlarmLower
Threshold

ADDTCU

Thedefaultvalueis
recommended.

ADDTCU

Temperature
AlarmLower
Threshold

TLTHD

TLTHD

SETBTSDHEUBP
Temperature
AlarmUpper
Threshold

Temperature
AlarmUpper
Threshold

TUTHD

TUTHD

SETBTSDHEUBP
Special
Boolean
AlarmFlag

Special
Boolean
AlarmFlag

SBAF

CCU
Special
Boolean
AlarmFlag

SBAF

Special
Boolean
AlarmFlag

Setthisparameter
to68fortheTCUin
othercabinets.

ADDTCU

Thedefaultvalueis
recommended:
WS_DISABLE(Water
ImmersedSensor
Disabled)and
SS_DISABLE(Smog
SensorDisabled)

ADDCCU

Thedefaultvalueis
recommended:
WS_DISABLE(Water
ImmersedSensor
Disabled)and
SS_DISABLE(Smog
SensorDisabled)

SBAF

SETBTSCCUBP
SBAF

Setthisparameter
to50fortheTCUin
theBBC.

EMU

Temperature
AlarmLower
Threshold

TLTHD

Temperature
AlarmUpper
Threshold

TUTHD

Humidity
AlarmLower
Threshold

HLTHD

Humidity
AlarmUpper
Threshold

HUTHD

SETBTSEXD

Temperature
AlarmLower
Threshold

SETBTSEXD

Temperature
AlarmUpper
Threshold

TUTHD

Humidity
AlarmLower
Threshold

HLTHD

Humidity
AlarmUpper
Threshold

HUTHD

SETBTSEXD

SETBTSEXD

TLTHD

ADDEMU

Thedefaultvalueis
recommended.

ADDEMU

Thedefaultvalueis
recommended.

ADDEMU

Thedefaultvalueis
recommended.

ADDEMU

Thedefaultvalueis
recommended.

SETBTSDEMUBP

Itisrecommended
that48V_DISABLE
becleared.

SetRES0and
RES1,andselect
RES2.
SetTS_DISABLE
andHS_DISABLE
basedonthetypes
ofsensors
connectedtothe
EMUorEMUA.

Special
AnalogAlarm
Flag

Special
AnalogAlarm
Flag

SAAF

SAAF

ADDEMU

SETBTSDEMUBP
Special
Boolean
AlarmFlag

Special
Boolean
AlarmFlag

SBAF

SBAF

ADDEMU

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.

PN

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonalarm
cableconnection.
Ifacustomizedalarm
needstobe
configured,setthe
parametertoON.If
else,settoOFF.

ALMPORT
PN

SET
BTSENVALMPORT

Switch

SW

SET
BTSENVALMPORT

Switch

SW

SET
ALMPORT

AlarmID.

AID

SET
BTSENVALMPORT

AlarmID.

AID

SET
ALMPORT

Setthevalueinthe
rangeof65033~
65233.

SET
ALMPORT

Itisrecommended
thatthisparameterbe
settoVALUEor
BOOLbasedon
customizedalarm
type.

SET
ALMPORT

Itisrecommended
thatthisparameterbe
settohighlevelor
lowlevelbasedon
alarmcable
connection.

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.

PortNo.

PortType

Alarm
Voltage

AlarmUpper
Limit

AlarmLower
Limit

SensorType

PT

AVOL

UL

LL

ST

SET
BTSENVALMPORT

SET
BTSENVALMPORT

SET
BTSENVALMPORT

SET
BTSENVALMPORT

SET
BTSENVALMPORT

PortNo.

PortType

Alarm
Voltage

AlarmUpper
Limit

AlarmLower
Limit

SensorType

PT

AVOL

UL

LL

ST

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe

EMUorEMUA.

Sensor
Measurement
UpperLimit

Sensor
Measurement
LowerLimit

Sensor
OutputUpper
Limit

Sensor
OutputLower
Limit

SMUL

SMLL

SOUL

SOLL

SET
BTSENVALMPORT

SET
BTSENVALMPORT

Sensor
Measurement
UpperLimit

Sensor
Measurement
LowerLimit

SET
BTSENVALMPORT

Sensor
OutputUpper
Limit

SET
BTSENVALMPORT

Sensor
OutputLower
Limit

SMUL

SMLL

SOUL

SOLL

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.

SET
ALMPORT

Itisrecommended
thatthisparameterbe
setbasedonthe
typesofsensors
connectedtothe
EMUorEMUA.

Thealarmparametersrelatedtotheexternalenvironment,suchaswaterandsmokesensorparametersmustbeconfigured

consistentlyforbothmodes.
Ifanyinconsistencyisdetected,thebasestationsofbothmodeswillreportthealarmALM26271InterSystemMonitoringDevice
ParameterSettingsConflict.
Toavoidinconsistency,youcanperformanMBTSconsistencycheckafterconfiguringparameters.Toperformaconsistencycheckon
theCMEclient,chooseMBTSApplication>MBTSCheckConsistencyfromthemenubarofacurrentorplanneddataarea.To
performaconsistencycheckontheM2000client,chooseCMExpress>MBTSApplication>MBTSCheckConsistency.For
detailedoperations,seesection"CheckingMBTSDataConsistency"inCMEConfigurationManagement.

7ReferenceDocuments
Thischapterliststhereferencedocumentsrelatedtomonitoringmanagement:
[1]PowerManagementFeatureParameterDescription
[2]BaseStationCabinetsandSubracks(IncludingtheBBUSubrack)Configuration
[3]BTS3900(Ver.B)HardwareDescription
[4]BTS3900(Ver.C)HardwareDescription
[5]BTS3900(Ver.D)HardwareDescription
[6]BTS3900L(Ver.B)HardwareDescription
[7]BTS3900L(Ver.C)HardwareDescription
[8]BTS3900L(Ver.D)HardwareDescription
[9]BTS3900A(Ver.B)HardwareDescription
[10]BTS3900A(Ver.C)HardwareDescription
[11]BTS3900A(Ver.D)HardwareDescription
[12]BTS3900AL(Ver.A)HardwareDescription
[13]DBS3900HardwareDescription
[14]BTS3900CWCDMAHardwareDescription
[15]BTS3900C(Ver.C)HardwareDescription
[16]RRUspecifichardwaredescription
[17]TP48600AH17B1UserManual
[18]IBBS700D&IBBS700TUserManual
[19]InitialConfigurationof3900SeriesBaseStations
[20]eNodeBInitialConfigurationGuide
[21]EMUUserGuide
[22]EMUAUserGuide