Professional Documents
Culture Documents
3-20
si 5048
flexible
easy to use
Proven technology with new application areas for PV systems the SMA Multicluster System 12 is now suitable for operation on
the utility grid as well. In Germany, it complies with the applicable conditions for connection to the low-voltage grid of VDE-ARN 4105: With the battery inverters Sunny Island 6.0H or 8.0H and the NA-Box 12, commercial self-consumption and batterybackup systems of up to 100 kWp can be set up. On an international scale, the Grid-Connect-Box 12 can be used to form self-consumption and battery-backup systems with an output of up to 138 kWp. The new Multicluster-Box 12 is suitable for TN- and TT-grids
thanks to the integrated grounding contactor. In areas with very unstable utility grids, a diesel generator can also be connected.
For off-grid regions, the Multicluster-Box 12 allows powerful solar off-grid systems with up to 138 kWp to be set up ideal
for commercial enterprises and village power supplies in rural regions.
Technical data
Load connection
Number of connections
Rated power
Rated grid voltage
AC voltage range
Current at rated values
Terminals for connection N, L1, L2, L3
Fuse / maximum permissible fuse sizes
Sunny Island connections
Maximum number of devices
AC rated power / AC current at rated values
Rated operating voltage
Terminals for connection N, PE, L
Fuse
Generator connection
Number of connections
Rated grid input power
Nominal voltage
AC input current
Terminals for connection N, PE, L1, L2, L3
Fuse / maximum permissible fuse sizes
PV system connection
Number of connections
Rated power
Rated operating voltage
AC current at rated values
Terminals for connection N, PE, L1, L2, L3
Maximum permissible back-up fuse
NA-Box / Grid-Connect-Box connection
Number of connections
Rated input power
Rated operating voltage
Rated current / AC input current
Terminals for connection N, PE, L1, L2, L3
Maximum permissible back-up fuse
General data
Number of phases
Permitted grid configuration
Rated frequency / frequency range
Dimensions (W/H/D)
Weight
Maximum operating altitude above mean sea level
Degree of protection (according to IEC 60529)
EMC environment, interference / interference immunity
Humidity
Operating temperature range
Output power / rated power at 25 C
Output power / rated power between 25 C and 60 C
Data cables
Warranty (5 years)
EC Declaration of Conformity
Standard feature Optional feature Not available
Type designation
Multicluster-Box 12
1 x three-phase
138 kW
230 V / 400 V
172.5 V265 V
300 V433 V
3 x 200 A
Spring-cage terminals
NH1 / 200 A
12
72 kW / 12 x 26 A
230 V / 400 V
Spring-cage terminals
12 x circuit breaker C40 A
1 x three-phase
138 kW
230 V / 400 V
3 x 200 A
Spring-cage terminals
NH1 / 200 A
1 x three-phase
138 kW
230 V / 400 V
3 x 200 A
Spring-cage terminals
200 A
1 x three-phase
138 kW
230 V / 400 V
3 x 200 A
Spring-cage terminals
200 A
3
TN-S, TN-C-S and TT
50 Hz / 45 Hz to 65 Hz
200 kg
3,000 m
IP55
B/A
0% to 100%
-25 C to +60 C
138 kW
See "Derating Behavior" diagram
Yes
MC-BOX-12.3-20
Necessary components
OFF-GRID
Multicluster-Box 12
Technical data
Connection to utility grid
Number of connections
Rated input power
Rated operating voltage
Rated current / AC input current
Number of AC contactors
Terminals for connection N, PE, L1, L2, L3
Maximum permissible back-up fuse
Fuse / maximum permissible fuse sizes
Connection of Multicluster-Box 12
Number of connections
Rated input power
Rated operating voltage
Rated current / AC input current
Terminals for connection N, PE, L1, L2, L3
Maximum permissible back-up fuse
General data
Number of phases
Permitted grid configuration
Rated frequency / frequency range
Disconnection
Dimensions (W/H/D)
Weight
Maximum operating altitude above mean sea level
Degree of protection (according to IEC 60529)
EMC environment, interference / interference immunity
Operating temperature range
Humidity
Warranty (5 years)
EC Declaration of Conformity
Grid connection standard
NA-Box 12
Grid-Connect-Box 12
1 x three-phase
138 kW*
230 V / 400 V
3 x 200 A
2
Spring-cage terminals
200 A
-
1 x three-phase
138 kW
230 V / 400 V
3 x 200 A
1
Spring-cage terminals
Integrated fuse
NH1 / 200 A
1 x three-phase
138 kW
230 V / 400 V
3 x 200 A
Spring-cage terminals
200 A
1 x three-phase
138 kW
230 V / 400 V
3 x 200 A
Spring-cage terminals
200 A
3
TN-S, TN-C-S and TT
50 Hz / 45 Hz to 52 Hz
All poles
600 / 1,400 / 435 mm
(incl. 200 mm base)
103 kg
2,000 m
IP55
B/A
-20 C to +50 C
10% to 90%
Yes
VDE-AR-N 4105
3
TN-S, TN-C-S and TT
50 Hz / 45 Hz to 65 Hz
All poles+ not all poles
600 / 1,400 / 435 mm
(incl. 200 mm base)
103 kg
3,000 m
IP55
B/A
-25 C to +60 C
0% to 100%
Yes
NA-BOX-12.3-20
GRID-BOX-12.3-20
* for Germany: 100 kW power fed into the grid / 138 kW power drawn from the grid and 100 kWp PV
Type designation
Derating Behavior
MC-Box-12.3-20
138
0
25
30
35
40
45
50
55
60
PV INVERTERS
PV main
distribution box
LOAD
optional:
NA-BOX /
GRID-CONNECTBOX
MULTICLUSTER BOX
(Main AC distribution board)
Load contactor
UTILITY GRID
GENERATOR
Generator contactor
SUNNY ISLAND
BATFUSE
DC
BATTERY
AC
MULTICLUSTER
BOX
NA-BOX
Grid contactor 1
Grid contactor 2
UTILITY GRID
MULTICLUSTER
BOX
GRID-CONNECT-BOX
Grid contactor 1
UTILITY GRID
MULTICLUSTERSYSTEM12-DEN1520-V10 SMA and Sunny Island are registered trademarks of SMA Technology AG. Printed on FSC paper. All products and services described as well as technical data are subject to change, even for reasons of country-specific deviations, at any time without notice.
SMA assumes no liability for typographical or other errors. For current information, please visit www.SMA-Solar.com.