You are on page 1of 723

Plant Design System (PDS)

Piping Component Data

Version 2011 (V12)


June 2011
DPDS3-PB-200022H

Copyright
Copyright 1984-2011 Intergraph Corporation. All Rights Reserved.
Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement;
contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret
law, and international treaty, and may not be provided or otherwise made available without proper authorization from Intergraph
Corporation.

U.S. Government Restricted Rights Legend


Use, duplication, or disclosure by the government is subject to restrictions as set forth below. For civilian agencies: This was
developed at private expense and is "restricted computer software" submitted with restricted rights in accordance with
subparagraphs (a) through (d) of the Commercial Computer Software - Restricted Rights clause at 52.227-19 of the Federal
Acquisition Regulations ("FAR") and its successors, and is unpublished and all rights are reserved under the copyright laws of the
United States. For units of the Department of Defense ("DoD"): This is "commercial computer software" as defined at DFARS
252.227-7014 and the rights of the Government are as specified at DFARS 227.7202-3.
Unpublished - rights reserved under the copyright laws of the United States.
Intergraph Corporation
P.O. Box 240000
Huntsville, AL 35813

Terms of Use
Use of this software product is subject to the End User License Agreement ("EULA") delivered with this software product unless the
licensee has a valid signed license for this software product with Intergraph Corporation. If the licensee has a valid signed license
for this software product with Intergraph Corporation, the valid signed license shall take precedence and govern the use of this
software product. Subject to the terms contained within the applicable license agreement, Intergraph Corporation gives licensee
permission to print a reasonable number of copies of the documentation as defined in the applicable license agreement and
delivered with the software product for licensee's internal, non-commercial use. The documentation may not be printed for resale or
redistribution.

Warranties and Liabilities


All warranties given by Intergraph Corporation about equipment or software are set forth in the EULA provided with the software or
applicable license for the software product signed by Intergraph Corporation, and nothing stated in, or implied by, this document or
its contents shall be considered or deemed a modification or amendment of such warranties. Intergraph believes the information in
this publication is accurate as of its publication date.
The information and the software discussed in this document are subject to change without notice and are subject to applicable
technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document.
The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms
of this license. No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by
Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS
TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT.
Intergraph is not responsible for the accuracy of delivered data including, but not limited to, catalog, reference and symbol data.
Users should verify for themselves that the data is accurate and suitable for their project work.

Trademarks
Intergraph, the Intergraph logo, PDS, SmartPlant, FrameWorks, I-Convert, I-Export, I-Sketch, SmartMarine, IntelliShip, INtools,
ISOGEN, MARIAN, SmartSketch, SPOOLGEN, SupportManager, and SupportModeler are trademarks or registered trademarks of
Intergraph Corporation or its subsidiaries in the United States and other countries. Microsoft and Windows are registered
trademarks of Microsoft Corporation. Oracle, JD Edwards, PeopleSoft, and Retek are registered trademarks of Oracle Corporation
and/or its affiliates. MicroStation is a registered trademark of Bentley Systems Inc, all rights reserved. Other brands and product
names are trademarks of their respective owners.

Contents
Preface PDS ............................................................................................................................................... 15
Introduction ................................................................................................................................................ 17
Reference Data File Descriptions ......................................................................................................... 17
Piping Job Specification File Descriptions...................................................................................... 17
Non-Database Part of the Piping Job Specification ....................................................................... 18
Non-Database Part of Item Descriptions ........................................................................................ 19
Model Graphics .............................................................................................................................. 19
Design DDL .................................................................................................................................... 20
Seed File Definitions....................................................................................................................... 20
General Conventions ................................................................................................................................ 23
Variables Used in Symbols and Tables ................................................................................................ 32
Definition of Specific Variables ....................................................................................................... 32
Definition of Generic Variables ....................................................................................................... 35
Commodity Discussions ........................................................................................................................... 39
Piping Commodity Data ........................................................................................................................ 39
Basic Information ............................................................................................................................ 39
Non-parametric and Parametric Piping and Tubing (PIPING, TUBING) ........................................ 40
Valves (6Q1C) ................................................................................................................................ 43
On-line Fittings (6P2C) and In-line Fittings (6Q2C) .............................................................................. 74
Connect Point Data_GCP .............................................................................................................. 75
6Q2C01, Flange (in-line) ................................................................................................................ 80
6Q2C03, Reducing flange (in-line) (not-automatic) ........................................................................ 83
6Q2C04, Expander flange (in-line) (not-automatic) ....................................................................... 84
6Q2C06, Orifice flange (in-line) (not-automatic) ............................................................................ 84
6Q2C08, Blind flange (in-line) (not-automatic) ............................................................................... 86
6Q2C10, Open spectacle blank (in-line) (not-automatic) ............................................................... 87
6Q2C11, Closed spectacle blank (in-line) (not-automatic)............................................................. 87
6Q2C12, Blank disc (in-line) (not-automatic) ................................................................................. 87
6Q2C13, Blind spacer (in-line) (not-automatic) .............................................................................. 87
6Q2C14, Tapered spacer (in-line) (not-automatic) ........................................................................ 87
6Q2C15, Open spacer (in-line) (not-automatic) ............................................................................. 88
6Q2C16, End (in-line) (not-automatic) ........................................................................................... 88
6Q2C17, Head (in-line) (not-automatic) ......................................................................................... 88
6Q2C19, Plug (in-line) (not-automatic)........................................................................................... 89
6Q2C21, Cap (in-line) (not-automatic) ........................................................................................... 89
6Q2C23, Concentric diameter change (in-line) .............................................................................. 89
6Q2C24, Eccentric diameter change (in-line) (not-automatic) ....................................................... 89
6Q2C25, Coupling-connector (in-line) (not-automatic) .................................................................. 89
6Q2C26, Half coupling (in-line) (not-automatic) ............................................................................. 90
6Q2C27, Concentric reducer (in-line)............................................................................................. 91
6Q2C28, Eccentric reducer (in-line) (not-automatic) ...................................................................... 92
6Q2C32, Reducing coupling (in-line) (not-automatic) .................................................................... 92
6Q2C35, Concentric swage (in-line) .............................................................................................. 93
6Q2C36, Eccentric swage (in-line) (not-automatic) ....................................................................... 93

Plant Design System (PDS) Piping Component Data

Contents
6Q2C39, Union (in-line) (not-automatic) ........................................................................................ 94
6Q2C40, Orifice union (in-line) (not-automatic) ............................................................................. 94
6Q2C41, Dielectric union (in-line) (not-automatic) ......................................................................... 94
6Q2C43, Hose connection (in-line) (not-automatic) ....................................................................... 94
6Q2C44, Bushing (in-line) (not-automatic) ..................................................................................... 95
6Q2C46, Reducing insert (in-line) (not-automatic) ......................................................................... 95
6Q2C47, Pipe bend (in-line) ........................................................................................................... 95
6Q2C49, 5.625 deg elbow (in-line) (not-automatic) ....................................................................... 96
6Q2C51, 11.25 deg elbow (in-line) (not-automatic) ....................................................................... 96
6Q2C53, 22.5 deg elbow (in-line) (not-automatic) ......................................................................... 97
6Q2C55, <45 deg direction change (in-line) .................................................................................. 97
6Q2C56, 45 deg direction change (in-line) .................................................................................... 98
6Q2C57, 45 deg elbow (in-line) ...................................................................................................... 98
6Q2C59, 45 deg LR elbow (in-line) ................................................................................................ 99
6Q2C60, 45 deg long tangent elbow (in-line) ................................................................................. 99
6Q2C61, 45 deg 3D elbow (in-line) .............................................................................................. 100
6Q2C63, 45 deg union elbow (in-line) (not-automatic) ................................................................ 100
6Q2C65, 45 deg street elbow (in-line) (not-automatic) ................................................................ 100
6Q2C66, 45 deg short elbow (in-line)........................................................................................... 101
6Q2C68, 45 deg long elbow (in-line) ............................................................................................ 101
6Q2C73, 60 deg elbow (in-line) (not-automatic) .......................................................................... 101
6Q2C75, 45-90 deg direction change (in-line) ............................................................................. 101
6Q2C76, 90 deg direction change (in-line) .................................................................................. 102
6Q2C77, 90 deg elbow (in-line) .................................................................................................... 102
6Q2C79, 90 deg SR elbow (in-line).............................................................................................. 103
6Q2C80, 90 deg LR elbow (in-line) .............................................................................................. 103
6Q2C82, 90 deg LR long tangent elbow (in-line) ......................................................................... 104
6Q2C84, 90 deg reducing elbow (in-line) ..................................................................................... 104
6Q2C86, 90 deg 3D elbow (in-line) .............................................................................................. 104
6Q2C88, 90 deg union elbow (in-line) (not-automatic) ................................................................ 105
6Q2C90, 90 deg street elbow (in-line) (not-automatic) ................................................................ 105
6Q2C91, 90 deg reducing street elbow (in-line) (not-automatic) ................................................. 105
6Q2C93, 90 deg short elbow (in-line)........................................................................................... 106
6Q2C94, 90 deg long elbow (in-line) ............................................................................................ 106
On-line Fittings (6P3C) and In-line Fittings (6Q3C) ............................................................................ 106
Connect Point Data_Independent Variables ................................................................................ 107
6Q3C01, 180 deg return (in-line) (not-automatic) ........................................................................ 112
6Q3C03, 180 deg SR return (in-line) (not-automatic) .................................................................. 112
6Q3C05, 180 deg LR return (in-line) (not-automatic) ................................................................... 112
6Q3C07, 180 deg close return (in-line) (not-automatic) ............................................................... 112
6Q3C08, 180 deg medium return (in-line) (not-automatic) .......................................................... 113
6Q3C09, 180 deg open return (in-line) (not-automatic) ............................................................... 113
6Q3C14, Miter (in-line) (not-automatic) ........................................................................................ 113
6Q3C16, 45 deg miter (in-line) ..................................................................................................... 114
6Q3C18, 90 deg miter (in-line) ..................................................................................................... 115
6Q3C22, Tee (in-line) ................................................................................................................... 116
6Q3C24, Reducing branch tee (in-line) ........................................................................................ 117
6Q3C25, Reducing run and branch tee (in-line) .......................................................................... 119
6Q3C27, On-run union tee (in-line) (not-automatic) ..................................................................... 119
6Q3C28, On-branch union tee (in-line) (not-automatic) ............................................................... 119
6Q3C31, Street tee (in-line) (not-automatic) ................................................................................ 120
6Q3C34, Reducing instrument tee (in-line) (not-automatic)......................................................... 120
6Q3C36, Drip ring tee (in-line) (not-automatic) ............................................................................ 120

Plant Design System (PDS) Piping Component Data

Contents
6Q3C38, Basin tee (in-line) .......................................................................................................... 121
6Q3C45, True Y (in-line) (not-automatic) ..................................................................................... 121
6Q3C47, Lateral (in-line) .............................................................................................................. 121
6Q3C49, Reducing branch lateral (in-line) ................................................................................... 122
6Q3C50, Reducing run and branch lateral (in-line) ...................................................................... 123
6Q3C52, 90 deg short Y-branch (in-line) (not-automatic) ............................................................ 123
6Q3C53, 90 deg reducing short Y-branch (in-line) (not-automatic) ............................................. 123
6Q3C54, 90 deg long Y-branch (in-line) (not-automatic) ............................................................. 123
6Q3C55, 90 deg reducing long Y-branch (in-line) (not-automatic) .............................................. 124
6Q3C60, Cross (in-line) (not-automatic) ...................................................................................... 124
6Q3C62, Reducing branches cross (in-line) (not-automatic) ....................................................... 125
6Q3C63, Reducing run and branches cross (in-line) (not-automatic) .......................................... 125
6Q3C64, Basin cross (in-line) (not-automatic) ............................................................................. 126
6Q3C70, Saddle (in-line) .............................................................................................................. 126
6Q3C72, Sweepolet (in-line) ........................................................................................................ 126
6Q3C73, Weldolet (in-line) ........................................................................................................... 127
6Q3C74, Sockolet (in-line) ........................................................................................................... 127
6Q3C75, Thredolet (in-line) .......................................................................................................... 128
6Q3C76, Nippolet (in-line) ............................................................................................................ 128
6Q3C77, Elbolet (in-line) (not-automatic) ..................................................................................... 129
6Q3C78, Latrolet (in-line) (not-automatic) .................................................................................... 129
6Q3C79, Endolet (in-line) (not-automatic).................................................................................... 130
6Q3C80, Reinforcing pad (in-line) ................................................................................................ 130
6Q3C82, Reinforcing weld (in-line) .............................................................................................. 132
6Q3C84, Buttweld (in-line) (not-automatic) .................................................................................. 134
6Q3C86, Full Encirclement Reinforcement Pad (In-Line) ............................................................ 134
6Q3C88, Branch nipple (in-line) (not-automatic) .......................................................................... 134
6Q3C89, In-line nipple (in-line) (not-automatic) ........................................................................... 135
6Q3C95, Gasket ........................................................................................................................... 135
6Q3C97, Stud ............................................................................................................................... 137
Fire and Safety Piping Components, On-line (6P4C), In-line (6Q4C) ................................................ 140
Connect Point Data ...................................................................................................................... 141
6Q4C01, Fire monitor (in-line) ...................................................................................................... 145
6Q4C02, Elevated fire monitor (in-line) ........................................................................................ 145
6Q4C03, Remotely operated fire monitor (in-line) ....................................................................... 145
6Q4C04, Foam monitor (in-line) ................................................................................................... 146
6Q4C05 Elevated foam monitor (in-line) ...................................................................................... 146
6Q4C06, Remotely operated foam monitor (in-line) .................................................................... 146
6Q4C10, [2-way] fire hydrant (in-line) .......................................................................................... 147
6Q4C11, [2-way] fire hydrant w/monitor nozzle (in-line) .............................................................. 147
6Q4C13, 3-way fire hydrant (in-line) ............................................................................................ 147
6Q4C24, Hose reel (in-line) .......................................................................................................... 148
6Q4C25, Hose rack station (in-line) ............................................................................................. 148
6Q4C26, Foam chamber (in-line) ................................................................................................. 148
6P4C30, Wet sprinkler (on-line) ................................................................................................... 148
6P4C31, Pre-action sprinkler (on-line) ......................................................................................... 149
6P4C32, Spray sprinkler (on-line) ................................................................................................ 149
6Q4C38, Eye wash (in-line) ......................................................................................................... 149
6Q4C39, Safety shower (in-line) .................................................................................................. 149
6Q4C40, Safety shower and eye wash (in-line) ........................................................................... 149
6Q4C60, [2-way] siamese (in-line) ............................................................................................... 150
6Q4C66, [2-way] 90 deg siamese (in-line) ................................................................................... 150
In-Line Bio-Pharmaceutical Components (6Q5P) ............................................................................... 150

Plant Design System (PDS) Piping Component Data

Contents
Bio-Pharmaceutical Specification Components ........................................................................... 150
Bio-Pharmaceutical Operators ..................................................................................................... 160
Bio-Pharmaceutical Specialty Components ................................................................................. 161
Piping Specialty Components, On-line (6P6C) , In-line (6Q6C) ......................................................... 163
Named and Unamed Specialties .................................................................................................. 165
Connect Point Data ...................................................................................................................... 165
6Q6C01, Flame arrestor (in-line) (PID piping comp type 513)................................................... 168
6Q6C03, Hammer arrestor (in-line) (PID piping comp type 515) ............................................... 168
6Q6C04, Vent silencer (in-line) (PID piping comp type 516) ..................................................... 168
6Q6C05, In-line silencer (in-line) (PID piping comp type 517) ................................................... 168
6Q6C07, Exhaust head (in-line) (PID piping comp type 519) .................................................... 169
6Q6C09, Breather vent (in-line) (PID piping comp type 521) .................................................... 169
6Q6C11, Free vent w/o screen (in-line) (PID piping comp type 523) ........................................ 169
6Q6C12, Free vent w/screen (in-line) (PID piping comp type 524) ........................................... 169
6Q6C13, Motor operated valve (in-line) (with operator) ............................................................. 169
6Q6C15, Mixing T (in-line) (PID piping comp type 527) ............................................................ 169
6P6C17, Spray nozzle (on-line) (PID piping comp type 529) .................................................... 169
6Q6C21, Removable spool (in-line) (PID piping comp type 533) .............................................. 170
6Q6C23, Swing elbow (in-line) (PID piping comp type 535) ...................................................... 170
6Q6C28, Expansion joint (in-line) (PID piping comp type 540).................................................. 170
6Q6C30, Hinged expansion joint (in-line) (PID piping comp type 542) ..................................... 170
6Q6C32, Swivel joint (in-line) (PID piping comp type 544) ........................................................ 170
6Q6C34, Mechanical coupling (in-line) (PID piping comp type 546) ......................................... 171
6Q6C36, Flexible hose (in-line) (PID piping comp type 548) ..................................................... 171
6Q6C40, Sample cooler (in-line) (PID piping comp type 552) ................................................... 172
6Q6C45, Single basket strainer (in-line) (PID piping comp type 557) ....................................... 172
6Q6C47, Duplex basket strainer (in-line with operator) (PID piping comp type
559)............................................................................................................................................... 172
6Q6C49, T strainer (in-line) (PID piping comp type 561) ........................................................... 172
6Q6C51, Y strainer (in-line) (PID piping comp type 563) ........................................................... 173
6Q6C52, Temporary strainer (in-line) (PID piping comp type 564) ........................................... 173
6Q6C53, Basket strainer (in-line) (PID piping comp type 565) .................................................. 173
6Q6C55, Cone strainer (in-line) (PID piping comp type 567) .................................................... 174
6Q6C57, Flat plate strainer (in-line) (PID piping comp type 569) .............................................. 174
6Q6C59, Sump strainer (in-line) (PID piping comp type 571).................................................... 174
6Q6C64, Filter (in-line) (PID piping comp type 576) .................................................................. 174
6Q6C70, Steam trap (in-line) (PID piping comp type 582) ........................................................ 174
6Q6C71, Float steam trap (in-line) (PID piping comp type 583) ................................................ 174
6Q6C72, Inverted bucket steam trap (in-line) (PID piping comp type 584) ............................... 174
6Q6C74, Thermostatic steam trap (in-line) (PID piping comp type 586) ................................... 174
6Q6C76, Thermodynamic steam trap (in-line) (PID piping comp type 588) .............................. 174
6Q6C78, Impulse steam trap (in-line) (PID piping comp type 590) ........................................... 174
6Q6C99, Generic component (in-line) (PID piping comp type 611) .......................................... 175
Instrument Specialty Discussions ....................................................................................................... 175
Signal Lines (7N2A) ...................................................................................................................... 176
Control Valves and Regulators (7P1E) ........................................................................................ 176
Relief Devices (7P2C) .................................................................................................................. 186
Other in-line Instruments (7P3C) .................................................................................................. 191
Off-Line Instruments (7Q4D) ........................................................................................................ 201
Miscellaneous ..................................................................................................................................... 218
Valve Operators and Actuators .................................................................................................... 219
Piping Connectors ........................................................................................................................ 228
6Q3C83, Non-radial Reinforcing Weld ......................................................................................... 229

Plant Design System (PDS) Piping Component Data

Contents
Assemblies .......................................................................................................................................... 230
In-line Piping Macrocomponents (6N8C) ..................................................................................... 230
On-line Piping Macrocomponents (6P8C) .................................................................................... 230
Symbols .................................................................................................................................................... 231
Piping Commodity Symbols ................................................................................................................ 231
Piping Commodity Symbol Legend .............................................................................................. 231
Piping Commodity Symbol P1 ...................................................................................................... 232
Piping Commodity Symbol V1 ...................................................................................................... 233
Piping Commodity Symbol V2 ...................................................................................................... 234
Piping Commodity Symbol V2A ................................................................................................... 235
Piping Commodity Symbol V2B ................................................................................................... 235
Piping Commodity Symbol V3 ...................................................................................................... 236
Piping Commodity Symbol V4 ...................................................................................................... 237
Piping Commodity Symbol V6 ...................................................................................................... 238
Piping Commodity Symbol V8 ...................................................................................................... 239
Piping Commodity Symbol V11 .................................................................................................... 240
Piping Commodity Symbol V12 .................................................................................................... 241
Piping Commodity Symbol V13 .................................................................................................... 242
Piping Commodity Symbol V16 .................................................................................................... 243
Piping Commodity Symbol V18 .................................................................................................... 244
Piping Commodity Symbol V19 .................................................................................................... 245
Piping Commodity Symbol V26 .................................................................................................... 246
Piping Commodity Symbol V32 .................................................................................................... 247
Piping Commodity Symbol V33 .................................................................................................... 248
Piping Commodity Symbol V34 .................................................................................................... 249
Piping Commodity Symbol V38 .................................................................................................... 250
Piping Commodity Symbol V40 .................................................................................................... 251
Piping Commodity Symbol V41 .................................................................................................... 252
Piping Commodity Symbol V42 .................................................................................................... 253
Piping Commodity Symbol V51 .................................................................................................... 254
Piping Commodity Symbol V58 .................................................................................................... 255
Piping Commodity Symbol V62 .................................................................................................... 256
Piping Commodity Symbol V72 .................................................................................................... 257
Piping Commodity Symbol V81 .................................................................................................... 258
Piping Commodity Symbol V82 .................................................................................................... 259
Piping Commodity Symbol F1A .................................................................................................... 260
Piping Commodity Symbol F4 ...................................................................................................... 261
Piping Commodity Symbol F6 ...................................................................................................... 262
Piping Commodity Symbol F8 ...................................................................................................... 263
Piping Commodity Symbol F10_1 ................................................................................................ 264
Piping Commodity Symbol F10_2 ................................................................................................ 265
Piping Commodity Symbol F13 .................................................................................................... 266
Piping Commodity Symbol F14A .................................................................................................. 267
Piping Commodity Symbol F14B .................................................................................................. 268
Piping Commodity Symbol F17D ................................................................................................. 269
Piping Commodity Symbol F19 .................................................................................................... 270
Piping Commodity Symbol F25 .................................................................................................... 271
Piping Commodity Symbol F27 .................................................................................................... 272
Piping Commodity Symbol F28 .................................................................................................... 273
Piping Commodity Symbol F31 .................................................................................................... 274
Piping Commodity Symbol F32 .................................................................................................... 275
Piping Commodity Symbol F39 .................................................................................................... 276

Plant Design System (PDS) Piping Component Data

Contents
Piping Commodity Symbol F43_1 ................................................................................................ 277
Piping Commodity Symbol F43_2 ................................................................................................ 278
Piping Commodity Symbol F47 .................................................................................................... 279
Piping Commodity Symbol F47A .................................................................................................. 280
Piping Commodity Symbol F63 .................................................................................................... 281
Piping Commodity Symbol F84 .................................................................................................... 282
Piping Commodity Symbol F101 .................................................................................................. 283
Piping Commodity Symbol F114A ................................................................................................ 284
Piping Commodity Symbol F114B ................................................................................................ 285
Piping Commodity Symbol F114C ............................................................................................... 286
Piping Commodity Symbol F114D ............................................................................................... 287
Piping Commodity Symbol F122_1 .............................................................................................. 288
Piping Commodity Symbol F122_2 .............................................................................................. 289
Piping Commodity Symbol F125 .................................................................................................. 290
Piping Commodity Symbol F127 .................................................................................................. 291
Piping Commodity Symbol F128 .................................................................................................. 292
Piping Commodity Symbol F134 .................................................................................................. 293
Piping Commodity Symbol F145 .................................................................................................. 294
Piping Commodity Symbol F147 .................................................................................................. 295
Piping Commodity Symbol F150 .................................................................................................. 296
Piping Commodity Symbol F152 .................................................................................................. 297
Piping Commodity Symbol F154 .................................................................................................. 298
Piping Commodity Symbol F160 .................................................................................................. 299
Piping Commodity Symbol F163 .................................................................................................. 300
Piping Commodity Symbol F170 .................................................................................................. 301
Piping Commodity Symbol F172 .................................................................................................. 302
Piping Commodity Symbol F173 .................................................................................................. 303
Piping Commodity Symbol F176 .................................................................................................. 304
Piping Commodity Symbol F177 .................................................................................................. 305
Piping Commodity Symbol F180F ................................................................................................ 306
Piping Commodity Symbol F178 .................................................................................................. 307
Piping Commodity Symbol F179 .................................................................................................. 308
Piping Commodity Symbol F180 .................................................................................................. 309
Piping Commodity Symbol F182 .................................................................................................. 310
Piping Commodity Symbol F184 .................................................................................................. 311
Piping Commodity Symbol F188 .................................................................................................. 312
Fire and Safety Symbols ..................................................................................................................... 313
Fire and Safety Symbol FS1A ...................................................................................................... 313
Fire and Safety Symbol FS2B ...................................................................................................... 313
Fire and Safety Symbol FS10A .................................................................................................... 314
Fire and Safety Symbol FS10B .................................................................................................... 314
Fire and Safety Symbol FS11A .................................................................................................... 315
Fire and Safety Symbol FS11B .................................................................................................... 315
Fire and Safety Symbol FS13A .................................................................................................... 316
Fire and Safety Symbol FS13B .................................................................................................... 316
Fire and Safety Symbol FS24A .................................................................................................... 317
Fire and Safety Symbol FS26A .................................................................................................... 317
Fire and Safety Symbol FS26B .................................................................................................... 318
Fire and Safety Symbol FS30A .................................................................................................... 318
Fire and Safety Symbol FS38A .................................................................................................... 319
Fire and Safety Symbol FS39A .................................................................................................... 319
Fire and Safety Symbol FS60A .................................................................................................... 320
Fire and Safety Symbol FS66A338 .............................................................................................. 320

Plant Design System (PDS) Piping Component Data

Contents
Fire and Safety Symbol T-FS1A ................................................................................................... 321
Fire and Safety Symbol T-FS2B ................................................................................................... 321
Fire and Safety Symbol T-FS10A ................................................................................................. 322
Fire and Safety Symbol T-FS11A ................................................................................................. 322
Fire and Safety Symbol T-FS13A ................................................................................................. 323
Piping Specialty Symbols .................................................................................................................... 323
Piping Specialty Symbol S1AC .................................................................................................... 323
Piping Specialty Symbol S1BZ ..................................................................................................... 324
Piping Specialty Symbol S3AZ ..................................................................................................... 324
Piping Specialty Symbol S4AC .................................................................................................... 325
Piping Specialty Symbol S5AZ ..................................................................................................... 325
Piping Specialty Symbol S7AZ ..................................................................................................... 326
Piping Specialty Symbol S11BZ ................................................................................................... 326
Piping Specialty Symbol S13AZ ................................................................................................... 327
Piping Specialty Symbol S28AZ ................................................................................................... 327
Piping Specialty Symbol S28BZ ................................................................................................... 328
Piping Specialty Symbol S32BC .................................................................................................. 328
Piping Specialty Symbol S36AZ ................................................................................................... 329
Piping Specialty Symbol S49AC .................................................................................................. 329
Piping Specialty Symbol S51AC .................................................................................................. 330
Piping Specialty Symbol S53AC .................................................................................................. 330
Piping Specialty Symbol S64BC .................................................................................................. 331
Piping Specialty Symbol S70AC .................................................................................................. 331
Piping Specialty Symbol S70BC .................................................................................................. 332
Piping Specialty Symbol S78AC .................................................................................................. 332
Instrument Specialty Symbols ............................................................................................................. 333
Instrument Specialty Symbol I3AZ ............................................................................................... 333
Instrument Specialty Symbol I5AZ ............................................................................................... 333
Instrument Specialty Symbol I6AZ ............................................................................................... 334
Instrument Specialty Symbol I7AZ ............................................................................................... 334
Instrument Specialty Symbol I8AZ ............................................................................................... 335
Instrument Specialty Symbol I11AZ ............................................................................................. 335
Instrument Specialty Symbol I12AZ ............................................................................................. 336
Instrument Specialty Symbol I13AZ ............................................................................................. 336
Instrument Specialty Symbol I14AZ ............................................................................................. 337
Instrument Specialty Symbol I15AZ ............................................................................................. 337
Instrument Specialty Symbol I16AZ ............................................................................................. 338
Instrument Specialty Symbol I17AZ ............................................................................................. 338
Instrument Specialty Symbol I18AZ ............................................................................................. 339
Instrument Specialty Symbol I20AZ ............................................................................................. 339
Instrument Specialty Symbol I30AZ ............................................................................................. 340
Instrument Specialty Symbol I106BZ ........................................................................................... 340
Instrument Specialty Symbol I109BZ ........................................................................................... 341
Instrument Specialty Symbol I118BZ ........................................................................................... 341
Instrument Specialty Symbol I120AZ ........................................................................................... 342
Instrument Specialty Symbol I201AZ ........................................................................................... 342
Instrument Specialty Symbol I201BZ ........................................................................................... 343
Instrument Specialty Symbol I201CZ ........................................................................................... 343
Instrument Specialty Symbol I209AZ ........................................................................................... 344
Instrument Specialty Symbol I213AZ ........................................................................................... 344
Instrument Specialty Symbol I216AZ ........................................................................................... 345
Instrument Specialty Symbol I219AZ ........................................................................................... 345
Instrument Specialty Symbol I237AZ ........................................................................................... 346

Plant Design System (PDS) Piping Component Data

Contents
Instrument Specialty Symbol I253AZ ........................................................................................... 346
Instrument Specialty Symbol I301AZ ........................................................................................... 347
Instrument Specialty Symbol I324CZ ........................................................................................... 347
Instrument Specialty Symbol I324DZ ........................................................................................... 348
Instrument Specialty Symbol I324EZ ........................................................................................... 348
Instrument Specialty Symbol I324FZ ........................................................................................... 349
Miscellaneous Symbols ...................................................................................................................... 349
Miscellaneous Symbol OP3 ......................................................................................................... 349
Miscellaneous Symbol OP4 ......................................................................................................... 350
Miscellaneous Symbol OP5 ......................................................................................................... 350
Miscellaneous Symbol OP9373 ................................................................................................... 351
Miscellaneous Symbol OP_251 ................................................................................................... 351
Miscellaneous Symbol OP_271 ................................................................................................... 352
Miscellaneous Symbol OP_291 ................................................................................................... 352
Miscellaneous Symbol OP_292 ................................................................................................... 353
Miscellaneous Symbol OP_311 ................................................................................................... 353
Miscellaneous Symbol OP_331 ................................................................................................... 354
Miscellaneous Symbol OP_332 ................................................................................................... 354
Miscellaneous Symbol OP_333 ................................................................................................... 355
Miscellaneous Symbol OP_334 ................................................................................................... 355
Miscellaneous Symbol OP_351 ................................................................................................... 356
Miscellaneous Symbol OP_391 ................................................................................................... 356
Miscellaneous Symbol OP_401 ................................................................................................... 357
Miscellaneous Symbol OP_411 ................................................................................................... 357
Miscellaneous Symbol OP_412 ................................................................................................... 358
Miscellaneous Symbol OP_413 ................................................................................................... 358
Miscellaneous Symbol OP_451 ................................................................................................... 359
Miscellaneous Symbol OP_452 ................................................................................................... 359
Miscellaneous Symbol OP_453 ................................................................................................... 360
Miscellaneous Symbol OP_491 ................................................................................................... 360
Miscellaneous Symbol OP_492 ................................................................................................... 361
Miscellaneous Symbol OP_493 ................................................................................................... 361
Miscellaneous Symbol OP_494 ................................................................................................... 362
Miscellaneous Symbol OP_571 ................................................................................................... 362
Miscellaneous Symbol OP_572 ................................................................................................... 363
Miscellaneous Symbol OP_573 ................................................................................................... 363
Miscellaneous Symbol OP_574 ................................................................................................... 364
Miscellaneous Symbol OP_711 ................................................................................................... 364
Miscellaneous Symbol OP_731 ................................................................................................... 365
Miscellaneous Symbol OP_811 ................................................................................................... 365
Miscellaneous Symbol OP_851 ................................................................................................... 366
Miscellaneous Symbol OP_852 ................................................................................................... 366
Miscellaneous Symbol OP_853 ................................................................................................... 367
Miscellaneous Symbol OP_854 ................................................................................................... 367
Miscellaneous Symbol A1003 ...................................................................................................... 368
Miscellaneous Symbol A1005 ...................................................................................................... 368
Miscellaneous Symbol A1251 ...................................................................................................... 369
Miscellaneous Symbol A1331 ...................................................................................................... 369
Miscellaneous Symbol A1332 ...................................................................................................... 370
Miscellaneous Symbol S2003 ...................................................................................................... 370
Miscellaneous Symbol S3003 ...................................................................................................... 371
Bio-Pharmaceutical SpecificationComponent Symbols ...................................................................... 371
Bio-Pharm Specification Component Symbol FERR ................................................................... 371

10

Plant Design System (PDS) Piping Component Data

Contents
Bio-Pharm Specification Component Symbol FERS .................................................................... 372
Bio-Pharm Specification Component Symbol CAPT .................................................................... 372
Bio-Pharm Specification Component Symbol CAPSE ................................................................. 373
Bio-Pharm Specification Component Symbol HA ........................................................................ 373
Bio-Pharm Specification Component Symbol FA ......................................................................... 374
Bio-Pharm Specification Component Symbol FAS ...................................................................... 374
Bio-Pharm Specification Component Symbol MA ........................................................................ 375
Bio-Pharm Specification Component Symbol MAR ..................................................................... 375
Bio-Pharm Specification Component Symbol B90T ..................................................................... 376
Bio-Pharm Specification Component Symbol B90TC .................................................................. 377
Bio-Pharm Specification Component Symbol B90C .................................................................... 378
Bio-Pharm Specification Component Symbol B45T ..................................................................... 379
Bio-Pharm Specification Component Symbol B45TC .................................................................. 379
Bio-Pharm Specification Component Symbol B45C .................................................................... 380
Bio-Pharm Specification Component Symbol R180R .................................................................. 380
Bio-Pharm Specification Component Symbol R180C .................................................................. 381
Bio-Pharm Specification Component Symbol TT ......................................................................... 381
Bio-Pharm Specification Component Symbol TTRB .................................................................... 382
Bio-Pharm Specification Component Symbol TCB ...................................................................... 383
Bio-Pharm Specification Component Symbol TRCB ................................................................... 384
Bio-Pharm Specification Component Symbol TSCB .................................................................... 385
Bio-Pharm Specification Component Symbol TRSCB ................................................................. 385
Bio-Pharm Specification Component Symbol TICB ..................................................................... 386
Bio-Pharm Specification Component Symbol TSCR ................................................................... 386
Bio-Pharm Specification Component Symbol XT ......................................................................... 387
Bio-Pharm Specification Component Symbol XTRB .................................................................... 388
Bio-Pharm Specification Component Symbol XC ........................................................................ 389
Bio-Pharm Specification Component Symbol TC ........................................................................ 390
Bio-Pharm Specification Component Symbol TCR ...................................................................... 391
Bio-Pharm Specification Component Symbol TCSB .................................................................... 392
Bio-Pharm Specification Component Symbol TCRSB ................................................................. 392
Bio-Pharm Specification Component Symbol TCI ....................................................................... 393
Bio-Pharm Specification Component Symbol RCP ...................................................................... 393
Bio-Pharm Specification Component Symbol RCCL ................................................................... 394
Bio-Pharm Specification Component Symbol RCC ..................................................................... 394
Bio-Pharm Specification Component Symbol REP ...................................................................... 395
Bio-Pharm Specification Component Symbol RECL .................................................................... 395
Bio-Pharm Specification Component Symbol REC ...................................................................... 396
Bio-Pharm Specification Component Symbol CHA ...................................................................... 396
Bio-Pharm Specification Component Symbol C2HD ................................................................... 397
Bio-Pharm Specification Component Symbol C3HD ................................................................... 397
Bio-Pharm Specification Component Symbol CPAN ................................................................... 397
Bio-Pharm Specification Component Symbol CPHB ................................................................... 398
Bio-Pharm Specification Component Symbol CA ........................................................................ 398
Bio-Pharm Specification Component Symbol CSJ ...................................................................... 398
Bio-Pharm Specification Component Symbol CHD ..................................................................... 399
Bio-Pharm Specification Component Symbol VS2D .................................................................... 399
Bio-Pharmaceutical Operators ............................................................................................................ 401
Bio-Pharm Operator Symbol SOP_3 ............................................................................................ 401
Bio-Pharm Operator Symbol SOP_42 .......................................................................................... 402
Bio-Pharmaceutical Specialty Components ........................................................................................ 403
Bio-Pharm Specialty Component Symbol R180B ........................................................................ 403
Bio-Pharm Specialty Component Symbol R180S ........................................................................ 404

Plant Design System (PDS) Piping Component Data

11

Contents
Bio-Pharm Specialty Component Symbol VSDTP ....................................................................... 404
Bio-Pharm Specialty Component Symbol VSDTC ....................................................................... 405
Bio-Pharm Specialty Component Symbol VSCCB ....................................................................... 405
Bio-Pharm Specialty Component Symbol VSCCBU425 .............................................................. 405
Bio-Pharm Specialty Component Symbol VS3WD ...................................................................... 406
Bio-Pharm Specialty Component Symbol VS4WD ...................................................................... 407
Details Assumed ................................................................................................................................. 407
Detail V1 ....................................................................................................................................... 407
Detail V2 ....................................................................................................................................... 408
Detail V3 ....................................................................................................................................... 408
Detail V4 ....................................................................................................................................... 409
Detail V5 ....................................................................................................................................... 409
Detail V7 ....................................................................................................................................... 410
Detail V8 ....................................................................................................................................... 410
Detail H1 ....................................................................................................................................... 411
Detail H2 ....................................................................................................................................... 411
Detail H3 ....................................................................................................................................... 412
Detail H4 ....................................................................................................................................... 412
Detail F1 ....................................................................................................................................... 413
Detail F2 ....................................................................................................................................... 413
Detail F4 ....................................................................................................................................... 414
Detail F7 ....................................................................................................................................... 414
Detail F8 ....................................................................................................................................... 415
Detail P1 ....................................................................................................................................... 415
Detail P2 ....................................................................................................................................... 416
Detail P3 ....................................................................................................................................... 416
Detail P4 ....................................................................................................................................... 417
Detail P5 ....................................................................................................................................... 417
Detail P7 ....................................................................................................................................... 418
Detail P8 ....................................................................................................................................... 418
Detail P9 ....................................................................................................................................... 419
Detail T1 ....................................................................................................................................... 419
Detail T ......................................................................................................................................... 420
Detail T4 ....................................................................................................................................... 420
Detail L1 ....................................................................................................................................... 421
Detail L2 ....................................................................................................................................... 421
Detail L4 ....................................................................................................................................... 422
Detail L7 ....................................................................................................................................... 423
Detail L8 ....................................................................................................................................... 424
Piping and Instrument Symbol Notes ................................................................................................. 425
Assembly Notes .................................................................................................................................. 432
Commodity Code Descriptions .............................................................................................................. 435
Commodity Code Matrix ..................................................................................................................... 435
Flanged and Miscellaneous Fittings ................................................................................................... 436
Completing Materials .......................................................................................................................... 441
Fire and Safety Components .............................................................................................................. 442
Steam Specialties ............................................................................................................................... 443
Flanges ............................................................................................................................................... 446
Flanged Fittings................................................................................................................................... 453
Strainer Specialties ............................................................................................................................. 459
Instrument Specialties ......................................................................................................................... 465
Pipe Supports...................................................................................................................................... 475

12

Plant Design System (PDS) Piping Component Data

Contents
Labor Codes........................................................................................................................................ 488
Miscellaneous Wetted Fittings ............................................................................................................ 496
Miscellaneous Non-Wetted Fittings .................................................................................................... 497
Tubing and Hose ................................................................................................................................. 499
Pipe ..................................................................................................................................................... 504
Socket Fittings..................................................................................................................................... 516
Tubing Fittings..................................................................................................................................... 518
Socketwelded Fittings ......................................................................................................................... 524
Threaded Fittings ................................................................................................................................ 527
Underground Fittings .......................................................................................................................... 532
Valves ................................................................................................................................................. 535
Welded Fittings ................................................................................................................................... 551
Gaskets ............................................................................................................................................... 559
Bolting ................................................................................................................................................. 566
Calculations From ANSI-B31.1 and ANSI-B31.3 ................................................................................... 573
Codelists................................................................................................................................................... 577
General Comments ............................................................................................................................. 579
Comments Specific to Units of Measure Codelist Sets ...................................................................... 579
CL31, Object Types for Orthographic Drawings (40).......................................................................... 581
CL35, Approval Status (10) ................................................................................................................. 583
CL36, Structural Approval Status (15) ................................................................................................ 583
CL37, HVAC Approval Status (10)...................................................................................................... 584
CL50, Hold Status (10) ....................................................................................................................... 584
CL69, Equipment Divisions/Form Code (99) ...................................................................................... 584
CL125, Fluid Code/Connector Type (999) .......................................................................................... 585
CL130, Construction Status (15) ......................................................................................................... 589
CL145, Materials Grade (4500) .......................................................................................................... 589
CL148, Piping Materials Class Description (31999) ........................................................................... 625
CL160, Responsibility (25) .................................................................................................................. 636
CL180, Fabrication Category (99)....................................................................................................... 636
CL190, Coating Requirements (99) .................................................................................................... 637
CL200, Heat Tracing Requirements (10) ............................................................................................ 637
CL210, Heat Tracing Media (60) ......................................................................................................... 638
CL220, Insulation Purpose (40) .......................................................................................................... 639
CL230, Cleaning Requirements (99) .................................................................................................. 639
CL330, CP Type/Termination/Preparation (999) ................................................................................ 639
CL332, Schedule / Thickness Override .............................................................................................. 643
CL340, Safety Classification (99)........................................................................................................ 645
CL360, Stress Analysis Requirements (15) ........................................................................................ 645
CL365, Reporting Requirements (25) ................................................................................................. 645
CL366, Requirement to Reconstruct (10) ........................................................................................... 646
CL380, Piping Component Type (2500) ............................................................................................. 646
CL390, Action (40) .............................................................................................................................. 655
CL400, Option (999) ........................................................................................................................... 655
CL420, Piping Component Type/Source (25) ..................................................................................... 664
CL425, Piping/Tubing Type (25) ......................................................................................................... 664
CL430, Instrument Component Type/Source (25) .............................................................................. 664
CL499, Piping Notes (999) .................................................................................................................. 664
CL530, Accessory/Item Type (125) .................................................................................................... 667
CL550, Operator/Actuator Type (200) ................................................................................................ 667
CL570, Design Standard (200) ........................................................................................................... 669

Plant Design System (PDS) Piping Component Data

13

Contents
CL572, Wall Thickness Equation ........................................................................................................ 669
CL575, Geometry Standard (31999)................................................................................................... 669
CL576, Table Suffix/End Standard - Green (999) ............................................................................... 684
CL577, Table Suffix/End Standard - Red (999) .................................................................................. 688
CL578, Weight Code (399) ................................................................................................................. 692
CL990, Types of Piping Commodity Data Forms ............................................................................... 694
CL999, Standard Note Title (2000) ..................................................................................................... 695
CL1010, Area Units (25) ..................................................................................................................... 696
CL1028, Mass Units (40) .................................................................................................................... 697
CL1056, Temperature Units (15) ........................................................................................................ 697
CL1064, Pressure Units (40) .............................................................................................................. 698
CL1074, Density Units (35) ................................................................................................................. 699
CL1100, Weld Type (100) ................................................................................................................... 699
CL1162, Force Units (40) .................................................................................................................... 699
CL1201, Drawing Scale (540) ............................................................................................................. 700
CL1202, Drawing Size (199) ............................................................................................................... 700
CL1203, Interference Manager Approval Status (99) ......................................................................... 700
CL1204, Interference Clash Type ....................................................................................................... 700
CL1205, Interference Manager Action (10) ........................................................................................ 703
CL1207, Interference Manager Approval Method (10) ....................................................................... 703
CL1208, Clash Checking Option......................................................................................................... 703
CL1209, Clash Checking Volume Filter Option .................................................................................. 703
CL1310, Report Source (99) ............................................................................................................... 703
CL1312, Report Type (999) ................................................................................................................ 703
CL1410, Design Review Type (10) ..................................................................................................... 704
CL1605, Model Status ........................................................................................................................ 704
CL1610, Force Units for FrameWorks Plus (40) ................................................................................. 704
CL1620, Drawing View Directions (7) ................................................................................................. 705
CL1630, Drawing View Composition Status (4) .................................................................................. 705
CL1710, Document Source (99) ......................................................................................................... 705
CL1720, Document Type (999) ........................................................................................................... 706
CL1900, Isometric Drawing Type ........................................................................................................ 708
CL2000, PD_Draw Document Type (999) .......................................................................................... 709
Index ......................................................................................................................................................... 711

14

Plant Design System (PDS) Piping Component Data

Preface PDS
This document provides command reference information and procedural instructions for the Plant
Design System (PDS) Piping Component Data task.

List of PDS Documentation

DPDS3-PB-200003 - DesignReview Integrator (PD_Review) Reference Guide


DPDS3-PB-200004 - Drawing Manager (PD_Draw) User's Guide
DPDS3-PB-200005 - EE Raceway Modeling Reference Guide
DPDS3-PB-200006 - Interference Checker/Manager (PD_Clash) User's Guide
DPDS3-PB-200010 - PDS 3D Theory User's Guide
DPDS3-PB-200013 - PDS EDEN Interface Reference Guide Volume I : Piping
DPDS3-PB-200015 - PDS Equipment Modeling (PD_EQP) User's Guide
DPDS3-PB-200017 - PDS ISOGEN Reference Guide, Vol. 1
DPDS3-PB-200022 - PDS Piping Component Data Reference Guide
DPDS3-PB-200023 - PDS Project Setup Technical Reference
DPDS3-PB-200025 - PDS Stress Analysis Interface (PD_Stress) User's Guide
DPDS3-PB-200026 - Pipe Supports Modeler Reference Guide
DPDS3-PB-200028 - Piping Design Graphics (PD_Design) Reference Guide
DPDS3-PB-200030 - Project Administrator (PD_Project) Reference Guide
DPDS3-PB-200033 - Project Engineer HVAC (PE-HVAC) Reference Guide
DPDS3-PB-200034 - Reference Data Manager (PD_Data) Reference Guide
DPDS3-PB-200035 - Report Manager (PD_Report) User's Guide
DPDS3-PB-200041 - PDS EDEN Interface Reference Guide Volume 2 : Equipment
DPDS3-PB-200042 - PDS EDEN Interface Reference Guide Volume 3 : Pipe Supports
DPDS3-PE-200016 - PDS Express Project Creation Quick Start Guide
DPDS3-PE-200052 - PDS Ortho Draw User's Guide
DPDS3-PE-200029 - Piping Model Builder (PD_Model) Reference Guide
DPDS3-PE-200031 - Project Engineer HVAC Getting Started Guide
DPDS3-PE-200032 - Project Engineer HVAC Overview
DPDS3-PE-200045 - PDS Label Library Merger Utility
DPDS3-PE-200047 - PDS Reference Data Auditing Tool
DPDS3-PE-200048 - Pipe Supports Explorer Utility
DPDS3-PE-200050 - Batch Services Quick Start Guide
DPDS3-PE-200051 - Batch Services User's Guide

Plant Design System (PDS) Piping Component Data

15

SECTION 1

Introduction
This document explains the basis used in developing the Reference Data required for the
execution of the Piping Task.

See Also
Reference Data File Descriptions (on page 17)
Piping Job Specification File Descriptions (on page 17)
Non-Database Part of the Piping Job Specification (on page 18)
Non-Database Part of Item Descriptions (on page 19)
Model Graphics (on page 19)
Design DDL (on page 20)
Seed File Definitions (on page 20)

Reference Data File Descriptions


The files containing the piping reference data are delivered with the PDS product. Practice
independent data is delivered with PD_Shell in the directory c:\win32app\ingr\pdshell\lib. Practice
dependent data is delivered with RDUSRDB in the directory c:\win32app\ingr\rdusrdb.

Piping Job Specification File Descriptions


The files involved and a short description are given below. Refer to the description of the Piping
Job Specification in the Reference Data Manager (PD_Data) Reference Guide, for detailed
explanations.
c:\win32app\ingr\rdusrdb\spec_data\
This directory contains neutral files in the format required for definition. It includes definitions
made in the tables listed below:
Piping Materials Class Table (classes.pmc)
Piping Commodities Tables (*.pcd)
Taps Tables (taps.data)
c:\win32app\ingr\pdshell\
This is the database definition for the applicable database. The relational database holds the
information that constitutes the Piping Job Specification. The following database tables form
this database.
201 Piping Materials Class Data
202 Piping Commodity Specification Data
203 Piping Specialty Specification Data
204 Instrument Component Specification Data
205 Tap Properties Data
211 Piping Commodity Size-Dependent Material Data
212 Piping Commodity Implied Material Data
221 Reference Database Revision Management Data
231 Component Insulation Exclusion Data
232 Flange Insulation Exclusion Data
233 Piping Construction Tolerance Exclusion Data

Plant Design System (PDS) Piping Component Data

17

Introduction
240
241
242
243

Pipe Support Family


Pipe Support Commodity Data
Pipe Support Material Reference
Pipe Support Material Description Data

Non-Database Part of the Piping Job Specification


The files involved and a short description are given below. Refer to the Reference Data Manager
(PD_Data) Reference Guide for more information on these tables. Also refer to the Appendix
Codelists for detailed explanations about codelist sets.
c:\win32app\ingr\rdusrdb\us_pjstb.l.t
This library file contains data in the format required for definition and revision. It includes
definitions made in the tables listed below:
Commodity_Item_Name Table
Bend_Deflection Table
Pipe Run Length Table
Pipe Length Table
Gasket_Cmdty_Code_Gkt Table
Bolt_Length Table
Bolt_Cmdty_Code_Blt Table
Weld_Type Table
Field_Fit_Length Table
Default_End_Prep Table
Temperature-Pressure Tables
Diameters Tables
Thicknesses Tables
Materials Tables
Branches Tables
Gasket Gaps Tables
Fluid Code Tables
MTO Tables and Functions
c:\win32app\ingr\rdusrdb\us_pjstb.l
This library file contains data in the format required for execution by the task. It includes data
from all the sources listed in the description of the c:\win32app\ingr\rdusrdb\us_pjstb.l file.
c:\win32app\ingr\pdshell\lib\std_note.l.t
This file contains data in the format required for definition and revision. It includes all the
codelist sets used in the Piping Task.
c:\win32app\ingr\pdshell\lib\std_note.l
This library file contains data in the format required for execution by the task.

18

Plant Design System (PDS) Piping Component Data

Introduction

Non-Database Part of Item Descriptions


The files involved and a short description are given below. Refer to the description of the Material
Description Library and Label Description Library in the Reference Data Manager (PD_Data)
Reference Guide for detailed explanations.
c:\win32app\ingr\rdusrdb\us_shbom.l
This library file contains data in the format required for execution by the task. It includes:
The short descriptions for piping commodities, including those for implied components, as
a function of the commodity codes assigned to them in the piping materials classes.
The descriptions of all the tap codes.
c:\win32app\ingr\rdusrdb\us_lgbom.l
This library file contains data in the format required for execution by the task. It provides the
long descriptions for piping commodities, including those for implied components, as a
function of the commodity codes assigned to them in the Piping Materials Classes.
c:\win32app\ingr\pdshell\lib\labels.l
This library file contains data in the format required for execution by the task. It provides the
label definitions required for the execution of the Piping Task, including the preparation of
orthographic and isometric drawings.
These libraries do not have text libraries associated with them.

Model Graphics
The files involved and a short description are given below. Refer to the description of the Graphic
Commodity Library in the Reference Data Manager (PD_Data) Reference Guide for detailed
explanations.
c:\win32app\ingr\rdusrdb\us_pcdim.l.t
This file contains data in the format required for definition and revision. It includes all the
tables required to provide dimensions, surface area and weight data to the Piping Task during
interactive execution of the task. In addition to generic data, it includes specific data about:
Plain piping components
Valves
Fittings
Fire and safety components
Miscellaneous piping commodity components, including valve operators
c:\win32app\ingr\rdusrdb\us_pcdim.l
This library file contains data in the format required for execution by the task. It includes data
from all the sources listed in the description of c:\win32app\ingr\rdusrdb\us_pcdim.l.t.
c:\win32app\ingr\pdshell\lib\assembly.l.t
This file contains data in the format required for definition and revision. It includes the
definitions of all assemblies available for use with the task.
c:\win32app\ingr\pdshell\lib\assembly.l
This library file contains data in the format required for execution by the task. It includes data
from all the assemblies included in c:\win32app\ingr\pdshell\lib\assembly.l.t.

Plant Design System (PDS) Piping Component Data

19

Introduction

Design DDL
The file involved and a short description are given below.
c:\win32app\ingr\pdshell\ddl\design.ddl
This is the database definition of the relational database for the Design portion of the Piping
Task.

Seed File Definitions


The definitions that follow have been applied to the project seed files.
Description

Files(s)

Piping Job Specification


Piping Job Specification

c:\win32app\ingr\rdusrdb\spec_data\*

Alphanumeric Commodity Data

c:\win32app\ingr\pddata\sample\data\pcd_size.d
ata

Piping Job Specification Tables

c:\win32app\ingr\rdusrdb\us_pjstb.l

Notes

c:\win32app\ingr\pdshell\lib\std_note.l

Item Descriptions
Piping Commodities Short
Descriptions

c:\win32app\ingr\rdusrdb\us_shbom.l

Piping Commodities Long


Descriptions

c:\win32app\ingr\rdusrdb\us_lgbom.l

Piping Specialties, Pipe Supports


and Instrument Descriptions

c:\win32app\ingr\rdusrdb\us_spbom.l

Labels

c:\win32app\ingr\pdshell\lib\labels.l

Graphic Commodity Library


Eden modules

c:\win32app\ingr\pdshell\lib\pip_gcom.l

Commodity Dimension Tables

c:\win32app\ingr\rdusrdb\us_pcdim.l

Assemblies

c:\win32app\ingr\pdshell\lib\assembly.l

Miscellaneous

20

Color Table

c:\wc:\win32app\ingr\pdshell\seedz\*sdz.dgnin3
2app\ingr\pdshell\color\*

Model Seed File

c:\win32app\ingr\pdshell\seedz\*sdz.dgn

Plant Design System (PDS) Piping Component Data

Introduction
Description

Files(s)

Report Formats

c:\win32app\ingr\pdreport\sample\*.fmt
c:\win32app\ingr\pddata\sample\format\*.fmt
c:\win32app\ingr\pdprojec\sample\*.fmt
c:\win32app\ingr\pdclash\sample\*.fmt

Plant Design System (PDS) Piping Component Data

21

APPENDIX A

General Conventions

Unless otherwise indicated in this document, values for "specific" and "generic" parameters
will be stored in tables whose names are derived from parameters in the Piping Job
Specification.
Table names often use the character "_".
Any number of comments may be included in a table, using the convention described below:
Blank lines are allowed without limits. No special character is required to define their
presence.
Any number of lines with comments may be included. Each comment line must be
preceded by an "!". Comments are disregarded by the system.
The following comments are specific to the Piping Job Specification Table, to the Piping
Commodities Table and to the Taps Table:
Columns in the table may be separated by either single or double spaces. The following
comments apply:
If single spacing is preferred, a line with the following format is required:
Single_Spacing
Entries in the columns must be made without blank spaces.
If double spacing is preferred, a line with the following format is required:
Double_Spacing
Entries in the columns may have up to one blank space in them.
A sequence line will define the contents of each column in the table. This will be done by
identifying the attribute number from the applicable entity and DDL covered by each column.
Attributes that are not included in the table will be defined by preceding them with an "*". An
example is:
Sequence= 1 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 *3 *4
The spacing between the entries in the above order statement must be either single or double
depending upon whether the single or double format applies to the table. This includes the
space between "=" and the first number in the statement.
Units will be defined for each column of a table as the applicable of the codes shown below.
The indicated upper/lower case convention should be respected.
Measurement

Type

Unit Name Code

Angle

Degrees

DEG

Angle between runs

Degrees

DEC

Area

Square feet

FT2

Area

Square inches

IN2

Area

Square miles

Area
Area

Square yards
Square centimeters

Plant Design System (PDS) Piping Component Data

MI2
YD2
SCM

23

General Conventions
Measurement

Type

Unit Name Code

Area

Square kilometers

Codelisted attributes

INT

Density

Grams per cubic meter

GCM3

Density

Kilograms per cubic


decimeter

KG_DM3

Density

Kilograms per liter

Density

Kilopounds (kips) per


cubic foot

Density

Kilopounds (kips) per inch KLB_IN

Density

Kilopounds (kips) per foot KLB_FT

KG_L
KIPFT3

Density

Pounds per cubic foot

Density

Pounds per UK gallon


LB_

UKGAL

Density

Pounds per US gallon


LB_

USGAL

Density

Kilograms per cubic


meter

KGM3

Insulation Thickness

24

SKM

Inches

LBF3

IN

Insulation Thickness

Millimeters

MM

Length

Inches

IN

Length

Inches (decimal) I

N_DEC

Length

Millimeters (decimal)

MM_DEC

Mass

Grams

Mass

Grains

GRAIN

Mass

Kilograms

KG

Mass

Milligrams

MG

Mass

Tons (UK)

UKTON

Mass

Tons (US)

USTON

Nominal diameter

Inches

NPD_IN

Nominal diameter

Millimeters

NPD_MM

Pressure

Atmospheres

ATM

Pressure

Bars (Absolute)

BAR

Pressure

Bars (Gauge)

BAR_G

Pressure

Inches of water

INH2O

Plant Design System (PDS) Piping Component Data

General Conventions
Measurement

Type

Unit Name Code

Pressure

Inches of water at 32
degrees F

INH2O_32F

Pressure

Inches of mercury

INHG

Pressure

Inches of mercury at 32
degrees F

INHG_32F

Pressure

Kilograms per square


centimeter

KG_CM2

Pressure

Kilograms per square


centimeter (absolute)

KG_CM2_A

Pressure

Kilogram-force per meter KGF_M

Pressure

Kilogram-force per
millimeter

KGF_MM

Pressure

Kilonewtons per meter

KN_M

Pressure

Kilonewtons per
millimeter

KN_MM

Pressure

Kilopascals (Gauge)

KPA_G

Pressure

Pounds per foot

LB_FT

Pressure

Pounds per inch

LB_IN

Pressure

Millimeters of water

MMH2O

Pressure

Millimeters of mercury
(Torr)

MMHG

Pressure

Megapascals (Gauge)

MPA_G

Pressure

Newtons per meter

N_M

Pressure

Newtons per millimeter

N_MM

Pressure

Pascals (Gauge)

PAG

Pressure

Pounds per square inch


(Gauge)

PSIG

Density

Tons (US) per cubic foot

USTONFT3

Rating

RAT (CLXXX and XXX#


will be expressed as
XXX)

Schedule/Thickness

Inches

SC_TH_IN

Schedule/Thickness

Millimeters

SC_TH_MM

Stress

Pounds per square inch

PSI

Stress

Pascals (Absolute)

PA

Stress

Kilopascals (Absolute)

KPA

Plant Design System (PDS) Piping Component Data

25

General Conventions

26

Measurement

Type

Unit Name Code

Stress

Megapascals (Absolute)

MPA

Surface area

Square feet

SF

Surface area

Square meters

SM

Surface area

Square millimeters

SMM

Surface area/unit

Square feet per foot

SFF

Surface area/unit

Square meters per meter SM_M

Surface area/unit

Square millimeters per


meter

SMM_M

Temperature

Degrees Celsius

DC

Temperature

Degrees Fahrenheit

DF

Temperature

Degrees Kelvin

DK

Temperature

Degrees Rankin

DR

Unitless alphanumeric

AN*XX (where "XX"


defines the number of
characters)

Unitless floating point


value

REAL (same as DEC)

Unitless integer

INT

Unitless real number

DEC

Weight

Pounds

LB

Weight

Kilograms

KG

Weight/unit

Pounds per foot

LBF

Weight/unit
Kilograms per meter
KGM
All entries in the tables will be left justified.
Field locations and field lengths defined with XXXXs, WWWWs and ZZZZZs in this document
will be observed.
Fractions will not be used in defining any table value. They will be expressed in their decimal
equivalents.
Adjacent columns in a table will be separated by one or more spaces.
If a value in a table is not known, a "-" must be used in the corresponding field. The system
will interpret this entry to represent a blank value and such will be displayed in reports,
drawings and other such formal data outputs to the User. The dash shall not be enclosed in
quote marks, even if the field is for an alphanumeric value.
Real numbers without decimals may be expressed with or without a decimal point. For
example, a nominal diameter of twenty inches may be expressed as "20", or "20." or "20.0".
For the sake of consistency, all tables will show the value as "20".
All alphanumeric values in a table must be enclosed in single quotes; for example, 'ZZZZZZZ'.

Plant Design System (PDS) Piping Component Data

General Conventions

For tables with only one input column, the generic value ET_AL may be used in the input
column. The system will understand such entry to indicate that values in the line just prior to
that for ET_AL will apply to any input value equal to or greater than the value in that line.
The following conventions will apply to the definition of columns in a table with a table format
other than P8*, P9*, I8* or I9*, where * refers to any applicable alphanumeric character:
A definition must be made using the format described below regarding the number of
input and output columns involved:
No Inputs X No Outputs X
The number of input columns must not exceed 2. The number of output columns must
not exceed 9; it may be 0.
A definition must be made using the format described below regarding the units of
measure used in each column.
Units= NPD IN, SF, LB, INT, DEC, IN, RAT, IN, IN, IN
The following conventions will apply to the definition of data in a table with table format P8*,
P9*, I8* or I9*:
A definition does not need to be made regarding the number of input and output columns
involved. The number of input fields must not exceed 2. The number of output fields is
up to parameter P34 for component data and up to parameter Y27 for actuator data. A
blank line following a component will signify that the definition of the component has been
completed and that a new component will follow. The word "END" following a
component will signify the end to the table.
Each parameter in these tables must have the applicable units of measure defined, using
the format "Pii-Z" or "Yii-Z", where:
-A=AN*20
-D=AN*1
-E=INT
-G=NPD IN
-H=NPD MM
-J=SF
-L=LB
-N=IN
-P=DEG
The following conventions apply to the attribute "rating" with respect to the naming of data
tables:
The Piping Job Specification may express alphanumeric ratings in at least the following
formats: CLXXXX, XXXX# or OTXXXX. The entry in the table and the file names
representing the attribute "rating", however, will exclude characters such as "CL", "#" and
"OT" so that the same table may be used regardless of how rating was defined in the
Piping Job Specification. The above rating formats have been used in accordance with
the following criteria:
CLXXXX to refer to an ANSI or API pressure rating.
XXXX# to refer to a pressure rating defined by an organization other ANSI or API.
OTXXXX to refer to the rating of a connect point that meets the applicable ANSI or
API rating geometrically but not from a pressure carrying standpoint. An example of
the above is a valve supplied with flanged ends meeting the bolting pattern of ANSI
CL150 pressure rating but having pressure carrying characteristics different from
those of that ANSI rating.
Female ends for plastic pipe are usually defined in terms of "schedule/thickness" and not
in terms of "rating" as is common with female ends for most other components. To make

Plant Design System (PDS) Piping Component Data

27

General Conventions

28

female ends for plastic pipe follow the rules for other female ends, the applicable
"schedule/thickness" will be used as the value for "rating" for these components. If such
rating values consist of alphanumeric characters (including dashes), the system will
"strip" all such characters from the rating value in the Piping Job Specification and will
only use the numeric values in accessing the applicable tables. If such rating values
include decimal points, the decimal points will be converted to the character "$" in
accessing the applicable tables.
If the rating in the Piping Job Specification is expressed in terms of alphabetic characters
only, the system will use all such characters in accessing the data tables. The names of
the data tables will include all the alphabetic characters included in the Piping Job
Specification.
Another acceptable value for rating is "GRAVHD". This value may be used in the
Piping Job Specification and in the data tables for components rated to sustain a
nominal fluid head.
Another acceptable value for rating is "OTHER".
One acceptable value for rating is "NONE". This value may be used in the Piping Job
Specification and in the data tables for components whose ends would normally
require the use of the attribute rating as part of the table name but that for some
specific reason, a rating does not apply.
The schedule/thickness of piping components may be determined either by
look-up/calculation from a piping materials class or based on a value provided by the User
independent of the piping materials class. Comments in this paragraph define the latter
approach. The value of the override schedule/thickness attribute of each piping segment
may be either:
Left blank if the User wishes schedule/thickness to be determined from the applicable
piping materials class; or
Defined by the User entering a schedule/thickness value; or
Defined by data transfer from the P&ID Task. A value from the P&ID Task will only be
transferred to this attribute if the piping thickness flag in the P&ID segment has a value "
U"; in such case, the value from the P&ID segment schedule/thickness will be transferred
to the Piping Task override schedule/thickness. Otherwise, the value of the override
schedule/thickness in the Piping Task will be left blank
If the Piping Task software finds a non-blank value for the override schedule/thickness,
such value will be applied to all the components that belong to the segment. Such
definition will be respected during reconstruction of the piping system.
Schedule or thickness values will be shown for all components for which such values make
sense. In order of preference, schedule and thickness will be expressed in terms of:
Generic schedules, such as S-STD, S-XS and S-XXS.
Specific schedules, such as S-40, S-60 and S-80.
Thickness class, such as CL50 and CL51. For this situation, both the alpha and numeric
characters must be included in the "Sc/Th" column of the piping materials class and in the
corresponding table names.
"NREQD": This value is to be used in cases where all of the following conditions apply:
+ The thickness value is not required in purchasing the component.
+ Empty weights are not significantly affected by actual thickness values.
+ Either stress analysis is not applicable or, if applicable, the component is to be
considered infinitely rigid in stress analysis calculations.

Plant Design System (PDS) Piping Component Data

General Conventions

Specific wall thicknesses: To insure compatibility between data tables, the Piping Job
Specification and wall thickness calculations, thickness will be expressed as defined
below.
+ .XXXX if the thickness is less than 1 inch
+ X if the thickness is an even inch
+ X.XXX if the thickness is 1 inch or thicker
Trailing zeroes will not be included. Decimal points will not be included for numbers
without decimals. Examples of these rules follow: + .25 + .5 + 1 + 1.375 + 2.375
Where the schedule name exceeds the field length provided, for example S-SDR13.5, it
will be defined in terms of its wall thickness.
*XYYY: The need to perform a thickness calculation will be triggered by an entry with the
format "*XYYY" being present in the "Sc/Th" column of the Piping Commodities Table.
The letters that make this code have the following meaning:
The character "X" is an alphanumeric code that defines the equation to use in the
calculation. Possible values and their definitions are as follows: If the value for this
character is "C", the schedule/thickness for the applicable end of the component is to
be determined by calculations using the thickness equation defined for the piping
materials class in the "Thck Eqtn" column of the Define Piping Job Specification table.
The characters "YYY" define the casting, joint or structural grade quality factor (E)
times 100. This factor is one of the parameters used in the thickness calculation.
The User should be cautioned that if he is defining a calculation to be performed on a
seamless fitting (E=1) but wishes to match the thickness for the mating welded pipe
(E=0.85), the quality factor for the pipe should be entered here.
MATCH: The need to match the thickness of a component to that of the pipe of the same
diameter and of option 1 will be triggered by an entry with the format "MATCH" being
present in the "Sc/Th" column of the Piping Commodities Table.

Plant Design System (PDS) Piping Component Data

29

General Conventions

To minimize duplication when the same thickness can be expressed for metallic materials in
terms of either a generic or a specific schedule, the convention defined below will be used.
For a given nominal diameter, only the schedules shown in the line for that diameter will be
used in the Piping Job Specification and in the data tables.

The table shown below will be used to correlate English nominal pipe diameters with their
corresponding metric values.
Nominal Pipe Diameter
in

30

mm

0.125

0.250

0.375

10

0.500

15

0.750

20

Plant Design System (PDS) Piping Component Data

General Conventions
1.000

25

1.250

32

1.500

40

2.000

50

2.500

65

3.000

80

3.500

90

4.000

100

5.000

125

6.000

150

8.000

200

10.00

250

12.00

300

14.00

350

16.00

400

18.00

450

20.00

500

22.00

550

24.00

600

26.00

650

28.00

700

30.00

750

32.00

800

34.00

850

36.00

900

38.00

950

40.00

1000

42.00

1050

44.00

1100

46.00

1150

48.00

1200

Weight tables have been provided for components required by the piping materials classes for
at least the combinations of thickness shown in the applicable Thicknesses Tables.
Where a "." or a "-" is included in a parameter that is part of a table name, a "$" will be used to
represent them in both the table name and the ASCII file name. The actual character, and

Plant Design System (PDS) Piping Component Data

31

General Conventions
not the "$", will be displayed in all fields representing the actual attribute involved. Examples of
how thicknesses would be represented on the basis of the above rule follow:
.25 .........................................$25
.5 ..........................................$5
1 ...........................................1
1.375 .......................................1$375
2.375 .......................................2$375

Some tables require an "END" statement as their last line; others do not. Refer to specific
table formats in this document for actual requirements.
Revision management of Piping RDB data follows the conventions described below:
The applicable control document is updated.
The "Rev" and "Date" fields of the table that is changed are revised as appropriate.
The line in the table that was either newly created or revised is identified by having the
symbol ">" precede it. If the line was deleted, a ">" is placed above and below the line
deleted.
When a table is revised again, all previous revision marks are deleted.

Variables Used in Symbols and Tables


Definition of Specific Variables
Letters A through O are used to represent variables which are specific to a component:
Variables

End Type

Explanation

Any

component, this is the distance from the origin of the component


to the outermost face of any of its ends. For components that
have either ends with different terminations or branches that are
not normal to the main axis of the component, this is the distance
from the origin of the component to the outermost face of the end
in the vicinity of PCP1.

Bolted

This value will be included in the appropriate dimension table.

Male

Not applicable.

Female

This value will not be included in any dimension table. It may be


deduced from the expression E + Q using values of E and Q from
the appropriate tables.

Any

For components that have ends with identical terminations and


for which branches, if any, are normal to the main axis of the
component, this parameter does not apply. For components that
have either ends with different terminations or branches that are
not normal to the main axis of the component, this is the distance
from the origin of the component to the outermost face of the end
in the vicinity of PCP2.

Bolted

This value will be included in the appropriate dimension table.

Male

Not applicable.

32

Plant Design System (PDS) Piping Component Data

General Conventions
Variables

BCD

End Type

Explanation

Female

This value will not be included in any dimension table. It may be


deduced from the expression F + Q using values of F and Q from
the appropriate tables.

Bolted

This is the bolt circle diameter of the bolts required at a bolted


end, as defined in the table named "BLT_Term_Rat_TS" as a
function of the nominal pipe diameter, termination type, rating and
table suffix of the applicable bolted end.

Male

Not applicable.

Female

Not applicable.

Any

For components that have ends with identical terminations and


for which branches, if any, are normal to the main axis of the
component, this parameter does not apply. For components that
have either ends with different terminations or branches that are
not normal to the main axis of the component, this is the distance
from the origin of the component to the outermost face of the end
in the vicinity of PCP3.

Bolted

This value will be included in the appropriate dimension table.

Male

Not applicable.

Female

This value will not be included in any dimension table. It may be


deduced from the expression G + Q using values of G and Q from
the appropriate tables.

Any

For components that have ends with identical terminations and


for which branches, if any, are normal to the main axis of the
component, this parameter does not apply. For components that
have either ends with different terminations or branches that are
not normal to the main axis of the component, this is the distance
from the origin of the component to the outermost face of the end
in the vicinity of PCP4.

Bolted

This value will be included in the appropriate dimension table.

Male

Not applicable.

Female

This value will not be included in any dimension table. It may be


deduced from the expression H + Q using values of H and Q from
the appropriate tables.

Any

For components that have ends with identical terminations and


for which branches, if any, are normal to the main axis of the
component, this is the distance from the origin of the component
to any of its PCPs. For components that have either ends with
different terminations or branches that are not normal to the main
axis of the component, this is the distance from the origin of the
component to PCP1.

Bolted

This parameter may be deduced from the expression A + T using


values of A and T from the appropriate tables.

Male

This value will be included in the appropriate dimension table.

Plant Design System (PDS) Piping Component Data

33

General Conventions
Variables

End Type

Explanation

Female

This value will be included in the appropriate dimension table.

Any

For components that have ends with identical terminations and


for which branches, if any, are normal to the main axis of the
component, this parameter does not apply. For components that
have either ends with different terminations or branches that are
not normal to the main axis of the component, this is the distance
from the origin of the component to PCP2.

Bolted

This parameter may be deduced from the expression B + T using


values of B and T from the appropriate tables.

Male

This value will be included in the appropriate dimension table.

Female

This value will be included in the appropriate dimension table.

Any

For components that have ends with identical terminations and


for which branches, if any, are normal to the main axis of the
component, this parameter does not apply. For components that
have either ends with different terminations or branches that are
not normal to the main axis of the component, this is the distance
from the origin of the component to PCP3.

Bolted

This parameter may be deduced from the expression C + T using


values of C and T from the appropriate tables.

Male

This value will be included in the appropriate dimension table.

Female

This value will be included in the appropriate dimension table.

Any

For components that have ends with identical terminations and


for which branches, if any, are normal to the main axis of the
component, this parameter does not apply. For components that
have either ends with different terminations or branches that are
not normal to the main axis of the component, this is the distance
from the origin of the component to PCP4.

Bolted

This parameter may be deduced from the expression D + T using


values of D and T from the appropriate tables.

Male

This value will be included in the appropriate dimension table.

Female

This value will be included in the appropriate dimension table.

I,J,K,L,M,N

Any

For use in dimension tables for specific components as required


by component being defined.

Any

This is the overall length of the component considering the


outermost surface at each end of the component. For blanks
other than per API-590, their lengths are derived from the
API-590 thicknesses, plus the raised face depth, plus the CA
defined in codelist set CL575, Geometry Standards, less the
API-590 CA.

34

Plant Design System (PDS) Piping Component Data

General Conventions

Definition of Generic Variables


Letters P through Z are used to represent generic variables.
Variables

End Type

Explanation

Bolted

This is the outside diameter of a bolted end of the indicated


termination type, rating and nominal diameter, as defined in the
table named "BLT_Term_Rat_TS".

Male

This is the outside diameter of a male end of the indicated


termination type and nominal diameter, as defined in the table
named "MAL_Term_TS".

Female

The is the outside diameter of the female end of the component of


the indicated termination type, rating and nominal diameter, as
defined in the table named "FEM_Term_Rat_TS". For model
graphic purposes, it is desirable to have the value of this
parameter be larger than the value of the matching male
termination end. Components such as 90 degree elbows and tees
will not place, however, if the value of this parameter is made too
large. For this reason we have defined values for this parameter as
follows:

For PVC and CPVC female ends: same as the value of "P" for
the corresponding male termination type.

For all other female ends: 30% of the fitting OD at the female
end plus 70% of the matching pipe OD.

Bolted

Not applicable

Male

The value of this variable will be "0" for all male ends.

Female

This is the depth of socket, as defined in the table named


"FEM_Term_Rat_TS".
For socketwelded ends, this value will be the nominal depth of
socket less 1/16". The actual depth of socket less 1/16" will be
used to determine a component's dimensional parameters.
For female threaded ends, this is the thread engagement as
defined as follows:

In Table B2.1 for components complying with ANSI-B16.12


In Table B2.2 for all other components.

Plant Design System (PDS) Piping Component Data

35

General Conventions
Variables

End Type

Explanation

Bolted

This is the flange thickness, as defined in the table named


"BLT_Term_Rat_TS". This dimension represents the distance
from the outermost face of the flange to the back surface of the
flange on which the nut rests. It includes any projections that the
flange may have; for example, the raised face. For lapflanged
ends, it does not include the thickness of the pipe or stub end since
such is determined by the software at stud length calculation time;
it only includes the thickness of the loose flange used. This
parameter is primarily used for the calculation of stud length. When
dealing with specialty components, such as relief valves, and if the
User wanted to be precise about this parameter, he might have to
develop many generic tables. A practical alternative might be to
create a table in which values for this parameter would be large
enough to insure that short studs would not result.

Male

Not applicable

Female

Not applicable

Bolted

This is the seating depth, as defined in the table named


"BLT_Term_Rat_TS". This dimension represents the distance
from the outermost surface of the bolted end to the seating surface
of the gasket. It will only have a value for small groove, large
groove, small female and large female flanged ends and for
mechanical joints. The value of this parameter will be zero for all
other bolted ends.

Male

Not applicable

Female

Not applicable

Bolted

This is half of the gasket gap thickness, as defined in the Piping


Job Specification for the applicable piping materials class.

Male

Not applicable

Female

Not applicable

Bolted

This is the number of bolts required at a bolted connection, as


defined in the applicable of the tables listed below:

36

"STUD_Rat_TS", if the RDB option that involves CP


termination for bolt length calculations is not active; or

Plant Design System (PDS) Piping Component Data

General Conventions
Variables

End Type

Explanation

"STUD_Term_Rat_TS" if the RDB option that involves CP


termination for bolt length calculations is active
as a function of the nominal pipe diameter, termination type
(only if the RDB option that involves CP termination for bolt
length calculations is active), rating and table suffix of the
applicable bolted end.

Male

Not applicable

Female

Not applicable

Bolted

This variable represents the diameter of the bolt at the bolted


connection. The V variable is used in generic tables by Bolted
ends STUD_Rat_TS and STUD_Term_Rat_TS.

"STUD_Rat_TS", if the RDB option that involves CP


termination for bolt length calculations is not active; or

"STUD_Term_Rat_TS" if the RDB option that involves CP


termination for bolt length calculations is active
as a function of the nominal pipe diameter, termination type
(only if the RDB option that involves CP termination for bolt
length calculations is active), rating and table suffix of the
applicable bolted end.

W_i

Male

Not applicable

Female

Not applicable

Bolted

This is the nut allowance, as defined in the applicable of the tables


listed below:

"STUD_Rat_TS", if the RDB option that involves CP


termination for bolt length calculations is not active; or

"STUD_Term_Rat_TS" if the RDB option that involves CP


termination for bolt length calculations is active.
as a function of the nominal pipe diameter, termination type
(only if the RDB option that involves CP termination for bolt
length calculations is active), rating and table suffix of the
applicable bolted end. It includes the nut length as well as the
stud extension beyond the nut. Value W_0 defines the nut
allowance to be used with studs using standard nut
allowances. Value W_1 defines the nut allowance to be used
with machine bolts using standard nut allowances. Values W_i
(i=2-5) define the nut allowances to be used with either studs

Plant Design System (PDS) Piping Component Data

37

General Conventions
Variables

End Type

Explanation
(+ or no sign modifier value) or machine bolts (- modifier value)
using special nut allowances. This parameter will be used in
calculating the length of bolts required in a bolted connection.
Values for W_0 and W_1 were developed on the following
basis:

If data was available in the applicable industry standard


defining the desired stud and/or machine bolt lengths, values
for W_0 and W_1 were calculated using the criteria in Annex F
of ANSI-B16.5-1981. If the values so calculated resulted in too
short a length, however, they were increased to result in the
desired length. Such increase was mostly required when
tables with name format "STUD_Rat_TS" applied. For tables
with name format "STUD_Term_Rat_TS", such increase was
not required.

If data was not available in the applicable industry standard


defining the desired stud lengths, values for W_0 were
calculated using the criteria in Annex F of ANSI-B16.5-1981.

If data was not available in the applicable industry standard


defining the desired machine bolt lengths, values for W_1
were defined as "-"

Male

Not applicable

Female

Not applicable

Bolted

Not applicable

Male

This is the wall thickness of the applicable end of a component of


the indicated nominal diameter, as defined in the table named
"MALWT_Term_Sc/Th_TS_WC". For cement and plastic lined
components, the thickness of the lining will not be included in the
value for wall thickness. For integrally clad components, however,
the thickness of the cladding will be included in the value for wall
thickness and the corrosion allowance will be made equal to the
clad thickness.

Female

Not applicable.

Any

Yi variables are used to define operator and actuator


parameters.

38

Any

No specific meaning is attached to this variable.

Plant Design System (PDS) Piping Component Data

APPENDIX B

Commodity Discussions
Piping Commodity Data
This section defines requirements which are specific to piping components.

See Also
Basic Information (on page 39)
Non-parametric and Parametric Piping and Tubing (PIPING, TUBING) (on page 40)
Valves (6Q1C) (on page 43)
On-line Fittings (6P2C) and In-line Fittings (6Q2C) (on page 74)
On-line Fittings (6P3C) and In-line Fittings (6Q3C) (on page 106)

Basic Information
AABBCC Codes and Model Codes
The AABBCC code is the primary access key to the commodity items in the Piping Job
Specification. An AABBCC code is a generic code about which a more detailed definition is made
in the Piping Job Specification.
These detailed definitions are identified by a model code in the Commodity Item data table of the
PJS. Each model code is classified by:
AABBCC code
option
size ranges
end preparations
ratings
The model code includes the definition of the graphic representation of the component in the
piping model. Depending upon the circumstances:
One or more model codes can be assigned to one AABBCC code
The same model code can be assigned to different AABBCC codes.

Connect Point Data


Connect point dependent data about each component is organized in terms of green and red
connect points. The following conventions regarding the sequence of data in the Piping Job
Specification and the naming of the Interactive Data Tables are used to coordinate the two sets of
data:
If data is only shown under green connect point data, it applies to all ends of the component.
If a component has ends with different nominal diameters (regardless of other end properties),
the larger nominal diameter end(s) is defined as the green connect point.
If a component has ends with the same nominal diameter but other end properties that differ,
the following rules apply:
If the ends have different termination type, regardless of the values for
schedule/thickness, the end(s) whose end preparations have the lowest codelist number
are designated as the green connect point.

Plant Design System (PDS) Piping Component Data

39

Commodity Discussions

If the termination types are the same but the values for rating, schedule or thickness differ,
the "stronger" ends(s) are designated as the green connect point.

Abbreviations
The following abbreviations are used to describe the table name formats in this document.
(G) (R) Angle BrchTbl

Green Red Angle Branch Table

Cmdty Code GCP

Commodity Code Green Connect Point

GS MC

Geometric Industry Standard Model Code

Op/Ac Rat RCP

Operator/Actuator Pressure Rating Red Connect Point

Sc/Th Term TNF

Schedule Thickness End Termination Type Table Name


Format

TS

Table Suffix

WC

Weight Code

Non-parametric and Parametric Piping and Tubing (PIPING,


TUBING)
The AABBCC code for piping and tubing consists of the words PIPING and TUBING, respectively.
The Pipe Model Entity will apply to this class of piping components.
PIPING, Piping (in-line)
Non-parametric pipe (MC=PIPE) (SN=None)
TNF=None & None
Beveled ends
Tapered and beveled ends
Male flared ends
Male threaded ends
Male grooved ends
Spigot ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
The following comments apply to the above definition of piping:
No EDEN parametric code definition is required for its placement.
Both ends of the pipe have the same end preparation. It will be possible to "break" this
type of pipe after placement for insertion of another component.
The pipe length is determined at placement either by keying in the actual length or by
stringing the pipe between two existing components. The system will refuse to place
portions of piping, which are shorter that the "min length" value defined in table
PIPE_LENGTH. The system will return a warning if the User places a section of piping
which is shorter than the "preferred length" value defined in table PIPE_LENGTH.
Placement of taps is neither required nor possible.
TNF=None & None
Beveled/plain ends
Beveled/plain 3" field fit ends
Beveled/plain 6" field fit ends

40

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Male threaded/plain ends
Beveled/male grooved ends
Male threaded/male grooved ends
Male grooved/plain ends
Plain/plain 3" field fit ends
Plain/plain 6" field fit ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
For certain types of pipe, for example, reinforced concrete, the thickness is actually
determined by the Fabricator on the basis of specified conditions. For them, the value
"NREQD" is used for Sc/Th.
TNF=None & None
Spigot/push-on bell ends
Plain/push-on bell ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"
The following comments apply to the above definition of piping:
No EDEN parametric code definition is required for its placement.
Both ends of the pipe have different end preparation. Pipe placement must always start at
a fitting. The end preparation of the fitting will determine the end preparation of the pipe
which will be placed first. When pipe placement is completed, the end preparation of the
last end of the pipe will be checked for compatibility with that of the corresponding fitting
end, if one applies. If an incompatibility is detected with such fitting end, an error will be
returned by the system.
The pipe length is determined at placement either by key-in of actual length or by stringing
the pipe between two pre-existing components. The system will refuse to place portions
of piping, which are shorter that the "min length" value defined in table PIPE_LENGTH.
The system will return a warning if the user places a section of piping which is shorter than
the "preferred length" value defined in table PIPE_LENGTH.
Placement of taps is neither required nor possible.
Purchased Length Pipe
Purchased length pipe has its length defined in the pds_sort_code attribute of the Piping
Commodity Specification Data Table of the Material Reference Database. Purchased
length pipe, can be placed or extended such that the remainder length of the last pipe does
not exceed the pipe length threshold, as specified in the active Pipe Length Threshold Table.
The following considerations apply to the length of this type of pipe:
During manual component placement, the system will place, starting at the active
placement point, one length of pipe of the default length. If the available length is less than
the default length, a pipe will be placed to fit the available length. By choosing the
starting point for placement, the user will have control as to where the random length of
pipe is placed.
During automatic component placement, the system will start placing pipe of the default
length from whichever end applies and will continue doing so until the available length for
placement is less than the default length. An additional pipe will then be placed to fit the
remaining length. In this method of placement, the user has no control as to where the
random length of pipe is placed.
The system will refuse to place any portion of piping, which are shorter that the "min
length" value defined in table PIPE_LENGTH. The system will return a warning if the

Plant Design System (PDS) Piping Component Data

41

Commodity Discussions
user places a section of piping which is shorter than the "preferred length" value defined in
table PIPE_LENGTH.
TNF=None & None
Flanged/mechanical joint ends
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="Value"
TNF=None & None
Spigot/push-on bell ends
Plain/push-on bell ends
Plain/mechanical joint bell ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"
The following comments apply to the above definition of piping:
In the Piping Materials Class, the entry for model code will be preceded by an asterisk (*)
to signify to the software that piping with an EDEN parametric code definition is involved.
This asterisk is not part of the model code name itself and such will be recognized by data
check reports executed by PDS. The ends of the piping will be drawn per the following
convention:
Bolted ends will be represented per standard PDS practice using dimensions from the
applicable generic tables.
Female ends will be represented as a cone of the following dimensions:
The large end with dimensions from the applicable female generic tables.
An included cone of angle of 90 degrees.
A cone length determined by the above criteria in conjunction with the termination
type at the other end of the pipe.
Both ends of the pipe have different end preparation. Pipe placement must always start at
a fitting. The end preparation of the fitting will determine the end preparation of the pipe
which will be placed first. When pipe placement is completed, the end preparation of the
last end of the pipe will be checked for compatibility with that of the corresponding fitting
end, if one applies. If an incompatibility is detected with such fitting end, an error will be
returned by the system. It will not be possible to "break" this type of pipe after placement
for insertion of another component; if such action was required, deletion and replacement
of the pipe will be necessary.
The following considerations apply to the length of this type of pipe:
The model code (MC) for parametric pipe will consist of the letter "P" followed by an
integer that will define its default length. This length will be the "CP to CP" length,
rather than the "face to face" length. It will have as units of measure those that apply
to pipe length in the project.
During manual component placement, the system will place, starting at the active
placement point, one length of pipe of the default length. If the available length is
less than the default length, a pipe will be placed to fit the available length. By
choosing the starting point for placement, the user will have control as to where the
random length of pipe is placed.
During automatic component placement, the system will start placing pipe of the
default length from whichever end applies and will continue doing so until the
available length for placement is less than the default length. An additional pipe will
then be placed to fit the remaining length. In this method of placement, the user has
no control as to where the random length of pipe is placed.

42

Plant Design System (PDS) Piping Component Data

Commodity Discussions

During reconstruction, the system will replace default and non-default pipe lengths in
kind. If the new default length differs from the original default length, however, the
procedure define above for automatic component placement will be used.
The system will refuse to place any portion of piping, which are shorter that the "min
length" value defined in table PIPE_LENGTH. The system will return a warning if the
user places a section of piping which is shorter than the "preferred length" value
defined in table PIPE_LENGTH.
Placement of taps is required.

TUBING, Tubing (in-line)


Non-parametric tubing (MC=TUBING) (SN=None)
TNF=None & None
Male flared ends
Male ferrule ends
Male ferrule/plain ends
Plain ends
The following comments apply to the above definition of tubing:
No EDEN parametric code definition is required for its placement.
Both ends of the pipe have the same end preparation. It will be possible to "break" this
type of pipe after placement for insertion of another component.
The pipe length is determined at placement either by key-in of actual length or by stringing
the pipe between two pre-existing components. The system will refuse to place portions
of tubing, which are shorter that the "min length" value defined in table PIPE_LENGTH.
The system will return a warning if the user places a section of tubing which is shorter than
the "preferred length" value defined in table PIPE_LENGTH.
Placement of taps is neither required nor possible.

Valves (6Q1C)
The AABBCC code for valves consists of the AABB code 6Q1C followed by two numbers for the
specific type of valve.
The Piping Component database table (34) applies to these classes of piping components.

See Also
Connect Point Data (on page 44)
6Q1C01, Gate valve (in-line) (on page 50)
6Q1C02, Extended body gate valve (in-line) (on page 51)
6Q1C03, Conduit gate valve (in-line) (on page 52)
6Q1C04, Blank gate valve (in-line) (on page 52)
6Q1C05, 3-way valve (in-line) (on page 53)
6Q1C06, [2-way] ball valve (in-line) (on page 53)
6Q1C08, 3-way ball valve (in-line) (on page 54)
6Q1C11, [2-way] globe valve (in-line) (on page 55)
6Q1C12, [2-way] angle globe valve (in-line) (on page 56)
6Q1C13, 3-way globe valve (in-line) (on page 57)
6Q1C14, Y globe valve (in-line) (on page 57)
6Q1C16, [2-way] plug valve (in-line) (on page 58)
6Q1C18, 3-way plug valve (in-line) (on page 60)
6Q1C19, 4-way plug valve (in-line) (on page 60)
6Q1C22, Needle valve (in-line) (on page 60)

Plant Design System (PDS) Piping Component Data

43

Commodity Discussions
6Q1C26, Butterfly valve (in-line) (on page 60)
6Q1C30, Diaphragm valve (in-line) (on page 61)
6Q1C32, Knife gate valve (in-line) (on page 62)
6Q1C33, [2-way] slide valve (in-line) (on page 62)
6Q1C34, 3-way slide valve (in-line) (on page 63)
6Q1C37, Angle valve (in-line) (on page 64)
6Q1C38, Check valve (in-line) (directional) (on page 64)
6Q1C39, Wafer check valve (in-line) (directional) (on page 67)
6Q1C40, Angle check valve (in-line) (directional) (on page 67)
6Q1C41, Stop check valve (in-line) (directional) (on page 68)
6Q1C42, Angle stop check valve (in-line) (directional) (on page 68)
6Q1C43, Y stop check valve (in-line) (directional) (on page 68)
6Q1C50, Backflow preventer (in-line) (directional) (on page 69)
6Q1C51, Automatic recirculation valve (in-line) (directional) (on page 69)
6Q1C53, Angle blowdown valve (in-line) (on page 69)
6Q1C54, Y blowdown valve (in-line) (on page 70)
6Q1C56, Pinch valve (in-line) (on page 70)
6Q1C57, Float valve (in-line) (on page 70)
6Q1C58, Foot valve (in-line) (directional) (on page 70)
6Q1C62, Tank drain valve (in-line) (directional) (on page 71)
6Q1C69, Deluge valve (in-line) (on page 71)
6Q1C72, Hose valve (in-line) (on page 71)
6Q1C73, Angle hose valve (in-line) (on page 72)
6Q1C76, Vent-drain valve (in-line) (on page 72)
6Q1C80, Instrument root valve (in-line) (on page 72)
6Q1C81, 3-way instrument root valve (in-line) (on page 73)
6Q1C82, 4-way instrument root valve (yn-line) (on page 73)

Connect Point Data


For each component in the piping commodities part of the Piping Job Specification, component
specific data is defined in tables, as follows:

Green Connect Point Data Only


If only green connect point data appears in the definition of the component in the Piping Job
Specification and regardless of the termination type for the green connect point, the following
applies:
General data about the component is included in a table with format P15A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, weight of water plus all those
dimensional parameters required to display the component in the model whose values are not
defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P15B.
The name of the P15B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) B

44

Plant Design System (PDS) Piping Component Data

Commodity Discussions

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the component in the model that were not included in the P15A table.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, are less than or equal to 24, the empty weight of the valve, including the valve operator
weight, is included in a table with format P59. The name of this table is comprised of the
following parameter from the piping commodities part of the Piping Job Specification:
Cmdty Code
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the valve, including its
operator.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, exceed 24 and are less than or equal to 40, the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code for the valve operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator is included in a
table with format P60A. The name of this table is comprised of the following parameter from
the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code of the operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters of the valve operator, the remaining parameters are included in a
table with format P60B. The name of the P60B table is comprised of the following parameter
from the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_B
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the valve operator in the model that were not included in the P60A table.

Green and Red Connect Point Data, GCP Male, RCP=Male


If both green and red connect point data appear in the definition of the component in the Piping
Job Specification, the green connect point is not a male termination type and the red connect point
is a male termination type, the following applies:
General data about the component is included in a table with format P25A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P25B.
The name of the P25B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:

Plant Design System (PDS) Piping Component Data

45

Commodity Discussions
MC GS Term(G)_Rat(G) Term(R)_B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P25A
table.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, are less than or equal to 24, the empty weight of the valve, including the valve operator
weight, is included in a table with format P59. The name of this table is comprised of the
following parameter from the piping commodities part of the Piping Job Specification:
Cmdty Code
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the valve, including its
operator.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, exceed 24 and are less than or equal to 40, the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code for the valve operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator is included in a
table with format P60A. The name of this table is comprised of the following parameter from
the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code of the operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters of the valve operator, the remaining parameters are included in a
table with format P60B. The name of the P60B table is comprised of the following parameter
from the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_B
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the valve operator in the model that were not included in the P60A table.

Green and Red Connect Point Data, GCP Male, RCP Male
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification and if the neither the green nor the red connect points are a male termination
type, the following applies:
General data about the component is included in a table with format P26A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P26B.

46

Plant Design System (PDS) Piping Component Data

Commodity Discussions
The name of the P26B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P26A
table.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, are less than or equal to 24, the empty weight of the valve, including the valve operator
weight, is included in a table with format P59. The name of this table is comprised of the
following parameter from the piping commodities part of the Piping Job Specification:
Cmdty Code
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the valve, including its
operator.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, exceed 24 and are less than or equal to 40, the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code for the valve operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator is included in a
table with format P60A. The name of this table is comprised of the following parameter from
the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code of the operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters of the valve operator, the remaining parameters are included in a
table with format P60B. The name of the P60B table is comprised of the following parameter
from the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_B
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the valve operator in the model that were not included in the P60A table.

Green and Red Connect Point Data, GCP=Male, RCP=Male


If both green and red connect point data appear in the definition of the component in the Piping
Job Specification and both the green and the red connect points are male termination type, the
following applies:
General data about the component is included in a table with format P26A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Rat(G) Term(R) Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.

Plant Design System (PDS) Piping Component Data

47

Commodity Discussions
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P26B.
The name of the P26B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_GS_Term(G) Rat(G) Term(R) Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P26A
table.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, are less than or equal to 24, the empty weight of the valve, including the valve operator
weight, is included in a table with format P59. The name of this table is comprised of the
following parameter from the piping commodities part of the Piping Job Specification:
Cmdty Code
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the valve, including its
operator.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, exceed 24 and are less than or equal to 40, the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code for the valve operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator is included in a
table with format P60A.The name of this table is comprised of the following parameter from the
piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code of the operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters of the valve operator, the remaining parameters are included in a
table with format P60B. The name of the P60B table is comprised of the following parameter
from the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_B
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the valve operator in the model that were not included in the P60A table.

Green and Red Connect Point Data, GCP = Male, RCP Male
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification, the green connect point is a male termination type and the red connect point is
not a male termination type, the following applies:
General data about the component is included in a table with format P27A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Term(R) Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water

48

Plant Design System (PDS) Piping Component Data

Commodity Discussions
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P27B.
The name of the P27B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_GS_Term(G) Term(R) Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional parameters
required to display the component in the model that were not included in the P27A table.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, are less than or equal to 24, the empty weight of the valve, including the valve operator
weight, is included in a table with format P59. The name of this table is comprised of the
following parameter from the piping commodities part of the Piping Job Specification:
Cmdty Code
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the valve, including its
operator.
For piping valves whose operator types as defined in codelist set CL550, Operator/Actuator
Type, exceed 24 and are less than or equal to 40, the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code for the valve operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator is included in a
table with format P60A. The name of this table is comprised of the following parameter from
the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are the empty weight of the valve exclusive of
the operator weight, the operator weight, the model code of the operator, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters of the valve operator, the remaining parameters are included in a
table with format P60B. The name of the P60B table is comprised of the following parameter
from the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_B

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the valve operator in the model that were not included in the P60A table.
Unless otherwise indicated, all valves have operators. Refer to paragraph C.6.1 for
additional requirements regarding operators.
Valves and their operators are not placed during automatic component placement. They
must be positioned manually.
For the table format descriptions applicable to each component type, the GCP and RCP rating
and schedule/thickness that needs to be provided in the Piping Job Specification has been
listed. These values are required for one or more of the reasons indicated below and are not
necessarily part of the names of the tables that include data about the component.
To procure the component.

Plant Design System (PDS) Piping Component Data

49

Commodity Discussions

To access data tables. Refer to Section 4, Model Graphics Definitions, for a description of the
table formats.
To supply data required for stress analysis purposes.

6Q1C01, Gate valve (in-line)


Short pattern gate valve (MC=GATSP) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Long pattern, bolted or male ends gate valve (MC=GAT) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59, or
P26A, P60A & P60B
Flanged/mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD" or "Value"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"

50

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Regular pattern, female ends, full port gate valve (MC=GATF)
(SN=V1)
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Regular pattern, female ends, reduced port gate valve
(MC=GATR) (SN=V1)
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q1C02, Extended body gate valve (in-line)


Extended body gate valve (MC=GATEX) (SN=V2)
TNF=
P27A, P31A & P59
Male threaded/socketwelded ends
Male threaded/female threaded ends
Plain/socketwelded ends
Plain/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Extended body gate valve (MC=GATEXB) (SN=V2)

Plant Design System (PDS) Piping Component Data

51

Commodity Discussions
TNF=P27A, P31A & P59
Beveled/socketwelded ends
Beveled/female threaded ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"
Extended body gate valve (no iso operator) (MC=GATXBA) (SN=V2A)
This is used to place an olet valve similarly to a branch
component. Since this symbol is mapped in Isogen to one
derived from an olet type branch component, it is not
possible to place an iso operator on it.
TNF=P27A, P31A & P59
Olet/socketwelded ends
Olet/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Extended body gate valve (MC=GATXBB) (SN=V2B)
This is used to place an olet valve at a tap, for example at a cap.
TNF=P27A, P31A & P59
Olet/socketwelded ends
Olet/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q1C03, Conduit gate valve (in-line)


Conduit gate valve (MC=GATCON) (SN=V3)
TNF=

P15A, P31A & P59, or


p15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=

P15A, P31A & P59, or


P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C04, Blank gate valve (in-line)


Blank gate valve (no operator) (MC=GATBL) (SN=V4)
TNF=P15A & P59
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

52

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C05, 3-way valve (in-line)


Any of the model codes for 3-way valves may be used under
this AABBCC code.

6Q1C06, [2-way] ball valve (in-line)


Female ends, full port ball valve (MC=BALF) (SN=V6)
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Female ends, reduced port ball valve (MC=BALR) (SN=V6)
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Short pattern, bolted or male ends ball valve (MC=BALSP) (SN=V6)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"

Plant Design System (PDS) Piping Component Data

53

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Long pattern, bolted or male ends ball valve (MC=BALLP) (SN=V6)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Venturi pattern, bolted or male ends ball valve (MC=BALVP) (SN=V6)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C08, 3-way ball valve (in-line)


3-way ball valve (MC=BAL3W) (SN=V8)

54

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C11, [2-way] globe valve (in-line)


Short pattern globe valve (MC=GLOSP) (SN=V11)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Long pattern, bolted or male ends globe valve (MC=GLO)
(SN=V11)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Regular pattern, female ends, full port globe valve
(MC=GLOF) (SN=V11)

Plant Design System (PDS) Piping Component Data

55

Commodity Discussions
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Regular pattern, female ends, reduced port globe valve
(MC=GLOR) (SN=V11)
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q1C12, [2-way] angle globe valve (in-line)


Short pattern angle globe valve (MC=GLOASP) (SN=V12)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Long pattern angle globe valve (MC=GLOA) (SN=V12)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

56

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C13, 3-way globe valve (in-line)


3-way globe valve (MC=GLO3W) (SN=V13)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C14, Y globe valve (in-line)


Bolted or male ends, Y globe valve (MC=GLOY) (SN=V11)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Female ends, full port Y globe valve (MC=GLOYF) (SN=V11)
TNF=P15A, P31A & P59
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Female ends, reduced port Y globe valve (MC=GLOYR) (SN=V11)
TNF=P15A, P31A & P59
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

57

Commodity Discussions
The graphics for the valve operator will distinguish a Y
globe valve from a globe valve.

6Q1C16, [2-way] plug valve (in-line)


Short pattern, bolted or male ends plug valve (MC=PLUSP)
(SN=V16)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
Regular pattern, bolted or male ends plug valve (MC=PLU) (SN=V16)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
Venturi pattern, bolted or male ends plug valve (MC=PLUVP)
(SN=V16)

58

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
Bolted or male ends, full port and round bore plug valve
(MC=PLUFB) (SN=V16)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
Female ends, full port plug valve (MC=PLUF) (SN=V16)
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Female ends, reduced port plug valve (MC=PLUR) (SN=V16)

Plant Design System (PDS) Piping Component Data

59

Commodity Discussions
TNF=P15A, P31A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C18, 3-way plug valve (in-line)


3-way plug valve (MC=PLU3W) (SN=V18)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C19, 4-way plug valve (in-line)


4-way plug valve (MC=PLU4W) (SN=V19)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C22, Needle valve (in-line)


Needle valve (MC=NEE) (SN=V11)
TNF=P15A, P31A & P59
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C26, Butterfly valve (in-line)


Low pressure butterfly valve (MC=BFYLP) (SN=V26)

60

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Thru-bolted ends
Thru-bolted ends with integral gaskets
Thru-bolted with cap-screw ends
Thru-bolted with cap-screw ends with integral gaskets
Male grooved ends
Mechanical joint bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
High pressure butterfly valve (MC=BFYHP) (SN=V26)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Thru-bolted ends
Thru-bolted ends with integral gaskets
Thru-bolted with cap-screw ends
Thru-bolted with cap-screw ends with integral gaskets
Male grooved ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C30, Diaphragm valve (in-line)


Unlined metal diaphragm valve (MC=DIA) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Solid plastic diaphragm valve (MC=DIASP) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socket ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

61

Commodity Discussions
Plastic lined diaphragm valve (MC=DIAPL) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Glass lined diaphragm valve (MC=DIAGL) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C32, Knife gate valve (in-line)


Knife gate valve (MC=KNF) (SN=V32)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Thru-bolted ends
Thru-bolted ends with integral gaskets
Thru-bolted with cap-screw ends
Thru-bolted with cap-screw ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C33, [2-way] slide valve (in-line)


Slide valve (MC=SLI) (SN=V33)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59, or
P26A, P60A & P60B
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"

62

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59, or
P26A, P60A & P60B
Beveled/beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
This type of component is used to represent "simple"
slide valves from catalog data. Slide valves for FCCU
service is defined as control valves.

6Q1C34, 3-way slide valve (in-line)


3-way slide valve (MC=SLI3W) (SN=V34)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59, or
P26A, P60A & P60B
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P25A, P31A & P59, or
P25A, P60A & P60B
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59, or
P26A, P60A & P60B
Beveled/beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
This type of component is used to represent "simple"
slide valves from catalog data. Slide valves for FCCU
service is defined as control valves.

Plant Design System (PDS) Piping Component Data

63

Commodity Discussions

6Q1C37, Angle valve (in-line)


Any of the model codes for angle valves may be used under
this AABBCC code.

6Q1C38, Check valve (in-line) (directional)


Short pattern, lift check valve (no operator) (MC=CKLSP) (SN=V38)
TNF=P15A & P59
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Short pattern, swing check valve (no operator) (MC=CKSSP) (SN=V38)
TNF=P15A & P59
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Long pattern, bolted or male ends lift check valve (no
operator) (MC=CKL) (SN=V38)
TNF=P15A & P59
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Male grooved ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

64

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Long pattern, female ends, full port lift check valve (no
operator) (MC=CKLF) (SN=V38)
TNF=P15A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Regular pattern, female ends, reduced port lift check valve
(no operator) (MC=CKLR) (SN=V38)
TNF=P15A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Long pattern, bolted or male ends swing check valve (no
operator) (MC=CKS) (SN=V38)
TNF=P15A & P59
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Male grooved ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Regular pattern, female ends, full port swing check valve
(no operator) (MC=CKSF) (SN=V38)
TNF=P15A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

65

Commodity Discussions
TNF=P26A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Regular pattern, female ends, reduced port swing check valve
(no operator) (MC=CKSR) (SN=V38)
TNF=P15A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Regular pattern, Y-swing check valve (no operator) (MC=CKSY)
(SN=V38)
TNF=P15A & P59
Flanged ends
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Male grooved ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Regular pattern, female ends, Y reduced port lift check
valve (no operator) (MC=CKLRY) (SN=V38)
TNF=P15A & P59
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

66

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P26A & P59
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q1C39, Wafer check valve (in-line) (directional)


Long pattern wafer check valve (no operator) (MC=CKWF) (SN=V26)
TNF=P15A & P59
Thru-bolted ends
Thru-bolted ends with integral gaskets
Thru-bolted with cap-screw ends
Thru-bolted with cap-screw ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Short pattern wafer check valve (no operator) (MC=CKWFSP) (SN=V26)
TNF=P15A & P59
Thru-bolted ends
Thru-bolted ends with integral gaskets
Thru-bolted with cap-screw ends
Thru-bolted with cap-screw ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
The graphics for the operator used with a butterfly valve
will distinguish that valve from a wafer check valve.

6Q1C40, Angle check valve (in-line) (directional)


Short pattern, angle lift check valve (no operator)
(MC=CKALSP) (SN=V40)
TNF=P15A & P59
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Long pattern, angle lift check valve (no operator) (MC=CKAL)
(SN=V40)
TNF=P15A & P59
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

67

Commodity Discussions
TNF=P15A & P59
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C41, Stop check valve (in-line) (directional)


Stop check valve (MC=CKST) (SN=V41)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C42, Angle stop check valve (in-line) (directional)


Angle stop check valve (MC=CKAST) (SN=V42)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
The graphics for the valve operator will distinguish an
angle stop check valve from a stop check valve.

6Q1C43, Y stop check valve (in-line) (directional)


Y stop check valve (MC=CKYST) (SN=V41)

68

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C50, Backflow preventer (in-line) (directional)


Backflow preventer (no operator) (MC=CKBP) (SN=V38)
TNF=P15A & P59
Flanged ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C51, Automatic recirculation valve (in-line) (directional)


Automatic recirculation valve (no operator) (MC=CKAR)
(SN=V51)
TNF=P26A & P59
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P27A & P59
Beveled/flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q1C53, Angle blowdown valve (in-line)


Angle blowdown valve (MC=BDA) (SN=V12)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

69

Commodity Discussions
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C54, Y blowdown valve (in-line)


Y blowdown valve (MC=BDY) (SN=V11)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q1C56, Pinch valve (in-line)


Pinch valve (MC=PIN) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C57, Float valve (in-line)


Float valve (MC=FLO) (SN=V1)
TNF=P15A, P31A & P59, or
P15A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C58, Foot valve (in-line) (directional)


Foot valve (no operator) (MC=FOOT) (SN=V58)
TNF=P15A & P59
Flanged end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

70

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q1C62, Tank drain valve (in-line) (directional)


Tank drain valve (MC=TKDR) (SN=V62)
TNF=P26A, P31A & P59, or
P26A, P60A & P60B
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Note that this valve has been defined to require
definition of data about both the GCP and the RCP. This
was required by the fact that for some vendors, these
valves have ends with different diameters.

6Q1C69, Deluge valve (in-line)


Deluge valve (no operator) (MC=DEL) (SN=V1)
TNF=P15A & P59
Flanged ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q1C72, Hose valve (in-line)


Hose valve (MC=HOS) (SN=V72)
TNF=P15A, P31A & P59
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Male threaded/male hose ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P27A, P31A & P59
Male hose/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

71

Commodity Discussions

6Q1C73, Angle hose valve (in-line)


Angle hose valve (MC=HOSA) (SN=V73)
TNF=P15A, P31A & P59
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A, P31A & P59
Male threaded/male hose ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P27A, P31A & P59
Male hose/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q1C76, Vent-drain valve (in-line)


Vent/drain valves are defined as those valves which are
intended for the venting or draining of piping and/or
instruments. They may be, but most often are not used, in
the venting or draining of equipment. They often have end
preparations which differ from those of the regular in-line
valves in the piping materials class. They may be of any of
the types described elsewhere in this section. They are
chosen from a piping materials class.
Any of the model codes for 2-way valves may be used under
this AABBCC code.

6Q1C80, Instrument root valve (in-line)


Instrument root valves are defined as those 2-way valves
which are used to isolate off-line instruments (P&ID
definition) from the equipment or piping to which they are
connected. A piping materials class should include
instrument root valves for all instrument detail situations
requiring isolation, including consideration that the
instrument may be connected to a nozzle, to a pipe fitting
or to a plain section of piping. In defining instrument
root valves in a piping materials class, the need for
coordination with instrument root valves that have been
"implied" as part of P&ID instrument components must be
carefully considered.
Any of the model codes for 2-way valves may be used under
this AABBCC code.

72

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q1C81, 3-way instrument root valve (in-line)


3-way instrument root valve type 1 (MC=3WRV1) (SN=V81)
3-way instrument root valves are defined as those 3-way
valves which are used to isolate off-line instruments (P&ID
definition) from the equipment or piping to which they are
connected. A piping materials class should include 3-way
instrument root valves for all applicable instrument detail
situations requiring isolation.
TNF=P27A, P31A & P59
Male threaded/socketwelded ends
Male threaded/female threaded ends
Plain/socketwelded ends
Plain/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P26A, P31A & P59
Socketwelded/socketwelded ends
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q1C82, 4-way instrument root valve (yn-line)


4-way instrument root valve type 1 (MC=4WRV1) (SN=V82)
4-way instrument root valves are defined as those 4-way
valves which are used to isolate off-line instruments (P&ID
definition) from the equipment or piping to which they are
connected. A piping materials class should include 4-way
instrument root valves for all applicable instrument detail
situations requiring isolation.
TNF=P27A, P31A & P59
Male threaded/socketwelded ends
Male threaded/female threaded ends
Plain/socketwelded ends
Plain/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P26A, P31A & P59
Socketwelded/socketwelded ends
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

73

Commodity Discussions

On-line Fittings (6P2C) and In-line Fittings (6Q2C)


The applicability of the above AABB codes is as defined below for each component type.
The AABBCC code for fittings will consist of the applicable AABB code, 6P2C or 6Q2C, followed
by the two numbers for the specific type of fitting.
The Piping Component Model Entity and the Piping Component Analysis Entity will apply to these
classes of piping components.

See Also
Connect Point Data_GCP (on page 75)
6Q2C01, Flange (in-line) (on page 80)
6Q2C03, Reducing flange (in-line) (not-automatic) (on page 83)
6Q2C04, Expander flange (in-line) (not-automatic) (on page 84)
6Q2C06, Orifice flange (in-line) (not-automatic) (on page 84)
6Q2C08, Blind flange (in-line) (not-automatic) (on page 86)
6Q2C10, Open spectacle blank (in-line) (not-automatic) (on page 87)
6Q2C11, Closed spectacle blank (in-line) (not-automatic) (on page 87)
6Q2C12, Blank disc (in-line) (not-automatic) (on page 87)
6Q2C13, Blind spacer (in-line) (not-automatic) (on page 87)
6Q2C14, Tapered spacer (in-line) (not-automatic) (on page 87)
6Q2C15, Open spacer (in-line) (not-automatic) (on page 88)
6Q2C16, End (in-line) (not-automatic) (on page 88)
6Q2C17, Head (in-line) (not-automatic) (on page 88)
6Q2C19, Plug (in-line) (not-automatic) (on page 89)
6Q2C21, Cap (in-line) (not-automatic) (on page 89)
6Q2C23, Concentric diameter change (in-line) (on page 89)
6Q2C24, Eccentric diameter change (in-line) (not-automatic) (on page 89)
6Q2C25, Coupling-connector (in-line) (not-automatic) (on page 89)
6Q2C26, Half coupling (in-line) (not-automatic) (on page 90)
6Q2C27, Concentric reducer (in-line) (on page 91)
6Q2C28, Eccentric reducer (in-line) (not-automatic) (on page 92)
6Q2C32, Reducing coupling (in-line) (not-automatic) (on page 92)
6Q2C35, Concentric swage (in-line) (on page 93)
6Q2C36, Eccentric swage (in-line) (not-automatic) (on page 93)
6Q2C39, Union (in-line) (not-automatic) (on page 94)
6Q2C40, Orifice union (in-line) (not-automatic) (on page 94)
6Q2C41, Dielectric union (in-line) (not-automatic) (on page 94)
6Q2C43, Hose connection (in-line) (not-automatic) (on page 94)
6Q2C44, Bushing (in-line) (not-automatic) (on page 95)
6Q2C46, Reducing insert (in-line) (not-automatic) (on page 95)
6Q2C47, Pipe bend (in-line) (on page 95)
6Q2C49, 5.625 deg elbow (in-line) (not-automatic) (on page 96)
6Q2C51, 11.25 deg elbow (in-line) (not-automatic) (on page 96)
6Q2C53, 22.5 deg elbow (in-line) (not-automatic) (on page 97)
6Q2C55, <45 deg direction change (in-line) (on page 97)
6Q2C56, 45 deg direction change (in-line) (on page 98)
6Q2C57, 45 deg elbow (in-line) (on page 98)
6Q2C59, 45 deg LR elbow (in-line) (on page 99)
6Q2C60, 45 deg long tangent elbow (in-line) (on page 99)
6Q2C61, 45 deg 3D elbow (in-line) (on page 100)
6Q2C63, 45 deg union elbow (in-line) (not-automatic) (on page 100)
6Q2C65, 45 deg street elbow (in-line) (not-automatic) (on page 100)

74

Plant Design System (PDS) Piping Component Data

Commodity Discussions
6Q2C66, 45 deg short elbow (in-line) (on page 101)
6Q2C68, 45 deg long elbow (in-line) (on page 101)
6Q2C73, 60 deg elbow (in-line) (not-automatic) (on page 101)
6Q2C75, 45-90 deg direction change (in-line) (on page 101)
6Q2C76, 90 deg direction change (in-line) (on page 102)
6Q2C77, 90 deg elbow (in-line) (on page 102)
6Q2C79, 90 deg SR elbow (in-line) (on page 103)
6Q2C80, 90 deg LR elbow (in-line) (on page 103)
6Q2C82, 90 deg LR long tangent elbow (in-line) (on page 104)
6Q2C84, 90 deg reducing elbow (in-line) (on page 104)
6Q2C86, 90 deg 3D elbow (in-line) (on page 104)
6Q2C88, 90 deg union elbow (in-line) (not-automatic) (on page 105)
6Q2C90, 90 deg street elbow (in-line) (not-automatic) (on page 105)
6Q2C91, 90 deg reducing street elbow (in-line) (not-automatic) (on page 105)
6Q2C93, 90 deg short elbow (in-line) (on page 106)
6Q2C94, 90 deg long elbow (in-line) (on page 106)

Connect Point Data_GCP


For each component in the piping commodities part of the Piping Job Specification, component
specific data is defined in tables, as follows:

Green Connect Point Data Only, GCP=Male


If only green connect point data appears in the definition of the component in the Piping Job
Specification and if the connect point is a male termination type, the following applies:
General data about the component is included in a table with format P11A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, weight of water plus all those
dimensional parameters required to display the component in the model whose values are not
defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P11B.
The name of the P11B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_B

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the component in the model that were not included in the P11A table.
The empty weight of the component is included in a table with format P51. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Sc/Th(G)_WC
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the component.

Plant Design System (PDS) Piping Component Data

75

Commodity Discussions
Green Connect Point Data Only, GCP Male
If only green connect point data appears in the definition of the component in the Piping Job
Specification and if the connect point is not a male termination type, the following applies:
General data about the component is included in a table with format P15A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) Rat(G) A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, weight of water plus all those
dimensional parameters required to display the component in the model whose values are not
defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P15B.
The name of the P15B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G) Rat(G) B

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the component in the model that were not included in the P15A table.
The empty weight of the component is included in a table with format P52. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Sc/Th(G)_WC
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the component.

Green and Red Connect Point Data, GCP Male, RCP=Male


If both green and red connect point data appear in the definition of the component in the Piping
Job Specification, the green connect point is not a male termination type and the red connect point
is a male termination type, the following applies:
General data about the component is included in a table with format P25A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P25B.
The name of the P25B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) Term(R)_B
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P25A
table.

76

Plant Design System (PDS) Piping Component Data

Commodity Discussions

The empty weight of the component is included in a table with format P61. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat/Sc/Th(R)_WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP Male, RCP Male
If both green and red connect point data appear in the definition of the component in the piping
commodities part of the Piping Job Specification and neither the green nor the "red" connect
points are male termination types, the following applies:
General data about the component is included in a table with format P26A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P26B.
The name of the P26B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P26A
table.
The empty weight of the component is included in a table with format P62. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Rat(G) Term(R) Rat(R) Sc/Th(R)_WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP=Male, RCP=Male, MC WOL, SOL, TOL, NOL,
EOL, LOL, RPAD* or RWELD*
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification and both the green and red connect points are male termination type and the
model code is not WOL, SOL, TOL, NOL, EOL, LOL, RPAD* or RWELD*, the following applies:
General data about the component is included in a table with format P21A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) Term(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water

Plant Design System (PDS) Piping Component Data

77

Commodity Discussions
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P21B.
The name of the P21B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G) Term(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P21A
table.
The empty weight of the component is included in a table with format P63. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Sc/Th(R)_WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP=Male, RCP Male, MC WOL, SOL, TOL, NOL,
EOL LOL, RPAD* or RWELD*
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification, the green connect point is a male termination type, the red connect point is not
a male termination type and the model code is not WOL, SOL, TOL, NOL, EOL LOL, RPAD* or
RWELD*, the following applies:
General data about the component is included in a table with format P27A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Term(R) Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P27B.
The name of the P27B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_GS_Term(G) Term(R) Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P27A
table.
The empty weight of the component is included in a table with format P64. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat(R)_WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

78

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Green and Red Connect Point Data, GCP=Male, RCP=Male or Female, MC=WOL, SOL, TOL,
NOL, EOL or LOL
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification, the green connect point is a male termination type, the red connect point is
either a male or a female termination type and the model code is WOL, SOL, TOL, NOL, EOL or
LOL, the following applies:
General data about the component is included in a table with format P28A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat/Sc/Th(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P28B.
The name of the P28B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat/Sc/Th(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P28A
table.
The empty weight of the component is included in a table with format P65. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat/Sc/Th(R)_WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP=Male, RCP=Male, MC=RPAD*, RWELD*
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification and both the green and the red connect points are male termination types and
the model code is RPAD* or RWELD*, the following applies:
General data about the component is included in a table with format P29A. The name of this
table is comprised of the following parameters:
MC_GS_BrchTbl Angle A

The values for these parameters are derived from:


MC and GS from the piping commodities part of the Piping Job Specification
BrchTbl from the piping classes part of the Piping Job Specification
The "angle" of intersection between the header and the branch from data in the design
file.
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of
water plus all those dimensional parameters required to display the component in the
model whose values are not defined in a generic table.
These components do not require an overflow table.

Plant Design System (PDS) Piping Component Data

79

Commodity Discussions

The empty weight of these components will not be considered.


Unless otherwise indicated, all fittings are automatically placed in the Piping Task during
automatic component placement. Components to be placed automatically by the system will
be selected to match the CP preparation, CP rating and table suffix of the applicable CP of the
mating component or equipment nozzle.
Under the description of each table format applicable to each component type, the GCP and
RCP rating and schedule/thickness that needs to be provided in the Piping Job Specification
has been listed. These values are required for one or more of the reasons indicated below and
will not necessarily be part of the names of the tables that include data about the component.
To procure the component.
To access data tables. Refer to Section 4, Model Graphics Definitions, for a description of
the table formats.
To supply data required for stress analysis purposes.

6Q2C01, Flange (in-line)


Weld neck flange (MC=FWN) (SN=F1A)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Long weld neck flange (MC=FLWN) (SN=F1A)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Slip-on flange (MC=FSO) (SN=F1A)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Lap joint flange (MC=FL) (SN=F1A)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Plate flange (MC=FPL) (SN=F1A)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Short-stub-end, slip-on flange (MC=FSSSO) (SN=F1A)

80

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Short-stub-end, lap joint flange (MC=FSSL) (SN=F1A)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Short-stub-end, plate flange (MC=FSSPL) (SN=F1A)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Long-stub-end, slip-on flange (MC=FLSSO) (SN=F1A)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Long-stub-end, lap joint flange (MC=FLSL) (SN=F1A)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Filler flange (MC=FFIL) (SN=F1A)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Socket flange (MC=FS) (SN=F1A)
TNF=P26A & P62
Flanged/socket ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Socketwelded flange (MC=FSW) (SN=F1A)
TNF=P26A & P62
Flanged/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"

Plant Design System (PDS) Piping Component Data

81

Commodity Discussions
Threaded flange (MC=FTHD) (SN=F1A)
TNF=P26A & P62
Flanged/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Flanged connecting piece (MC=FCP) (SN=F1A)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
The following comments apply to the above items:
o The "rating" for the RCP, if applicable, is the same
as for the flange itself, regardless of the CP preparation
involved. A value is provided in the "rating" field
to minimize the number of weight tables required to define
these components.
o For flanges placed together with stub-ends, the flange
is defined in the piping materials class as the
primary component. The stub-end is defined as its
implied component, using the "*" prefix method.
o Prior to the automatic placement of flanges, all
user-placed components that have flanged ends must be
placed in the model. During automatic placement of
flanges, the system will determine whether the flange
being placed shares the CP preparation, CP rating and
table suffix of its previously placed mate. If it does,
the flange being placed is accepted; if it does not,
the system will search for the next occurrence of the
AABBCC code. The checking process is repeated until
a match is found. If a match is not found, error message
GMXXX is returned.
o During automatic component placement, the piping software
will refuse to attach slip-on or lap-joint flanges without
stub-ends to any kind of fitting. Only attachment of a
slip-on or lap-joint flange to a plain section of pipe
is allowed. For piping materials classes with
slip-on or lap-joint flanges, two flanges are defined:
a first one that will lead to a slip-on or lap-joint
flange; a second one that will lead to an acceptable
flange type for attachment to a fitting. If during
automatic component placement, the system refuses to
attach the first flange selected because of the above
criteria, a new search is made in the piping
materials class for the second flange.

82

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q2C03, Reducing flange (in-line) (not-automatic)


Weld neck reducing flange (MC=FRWN) (SN=F1A)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Slip-on reducing flange (MC=FRSO) (SN=F1A)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Plate reducing flange (MC=FRPL) (SN=F1A)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Socket reducing flange (MC=FRS) (SN=F1A)
TNF=P26A & P62
Flanged/socket ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Socketwelded reducing flange (MC=FRSW) (SN=F1A)
TNF=P26A & P62
Flanged/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Threaded reducing flange (MC=FRTHD) (SN=F1A)
TNF=P26A & P62
Flanged/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
The following comments apply to the above items:
o The "rating" for the RCP, if applicable, is the same
as for the flange itself, regardless of the CP preparation
involved. A value is provided in the "rating" field
to minimize the number of weight tables required to define
these components.

Plant Design System (PDS) Piping Component Data

83

Commodity Discussions

6Q2C04, Expander flange (in-line) (not-automatic)


Weld neck expander flange (MC=FEWN) (SN=F4)
TNF=P27A & P64
Beveled/flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"
The following comments apply to the above item:
o The "rating" for the GCP, if applicable, is the same
as for the flange itself, regardless of the CP preparation
involved.

6Q2C06, Orifice flange (in-line) (not-automatic)


Weld neck orifice flange w/0.5inch threaded taps (MC=FOWNA)
(SN=F6)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Weld neck orifice flange w/0.5inch socketwelded taps
(MC=FOWNAW) (SN=F6)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Weld neck orifice flange w/0.75inch threaded taps (MC=FOWNB)
(SN=F6)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Weld neck orifice flange w/0.75inch socketwelded taps
(MC=FOWNBW) (SN=F6)
TNF=P25A & P61
Flanged/beveled ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Slip-on orifice flange w/0.5inch threaded taps (MC=FOSOA)
(SN=F6)

84

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Slip-on orifice flange w/0.5inch socketwelded taps
(MC=FOSOAW) (SN=F6)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Slip-on orifice flange w/0.75inch threaded taps (MC=FOSOB)
(SN=F6)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Slip-on orifice flange w/0.75inch socketwelded taps
(MC=FOSOBW) (SN=F6)
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Socketwelded orifice flange w/0.5inch threaded taps
(MC=FOSWA) (SN=F6)
TNF=P26A & P62
Flanged/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Socketwelded orifice flange w/0.5inch socketwelded taps
(MC=FOSWAW) (SN=F6)
TNF=P26A & P62
Flanged/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Socketwelded orifice flange w/0.75inch threaded taps
(MC=FOSWB) (SN=F6)
TNF=P26A & P62
Flanged/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"

Plant Design System (PDS) Piping Component Data

85

Commodity Discussions
Socketwelded orifice flange w/0.75inch socketwelded taps
(MC=FOSWBW) (SN=F6)
TNF=P26A & P62
Flanged/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
Threaded orifice flange w/0.5 inch threaded taps (MC=FOTHDA)
(SN=F6)
TNF=P26A & P62
Flanged/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
The following comments apply to the above items:
o The tap connect point is placed a distance of one-half
the flange thickness from the face of the flange. This
distance may not be dimensionally correct per the industry
standards. The user must modify the Eden if exact
coordinates are required for tap locations.
o The "rating" for the RCP, if applicable, is the same
as for the flange itself, regardless of the CP preparation
involved. A value is provided in the "rating" field
to minimize the number of weight tables required to define
these components.
o The number of taps for orifice flanges, "1" or "2", will
be defined in the "Mod" column of the Piping Job
Specification. Only these values are acceptable.
o The "rating" for the taps is derived from the entry
in the applicable Taps Table with an option code of "1"
and having the tap size implied in the orifice flange
being placed.

6Q2C08, Blind flange (in-line) (not-automatic)


Blind flange (MC=FBLD) (SN=F8)
TNF=P52
Flanged end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
A specific table will not be required for definition of
dimensions of blind flanges.

86

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q2C10, Open spectacle blank (in-line) (not-automatic)


Open spectacle blank (MC=BLSPO) (SN=F10_1)
TNF=P15A & P52
Thru-bolted ends
Thru-bolted ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C11, Closed spectacle blank (in-line) (not-automatic)


Closed spectacle blank (MC=BLSPC) (SN=F10_2)
TNF=P15A & P52
Thru-bolted ends
Thru-bolted ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C12, Blank disc (in-line) (not-automatic)


Blank disc (MC=BDISC) (SN=F13)
TNF=P15A & P52
Thru-bolted ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C13, Blind spacer (in-line) (not-automatic)


Paddle blank (MC=BLPAD) (SN=F13)
TNF=P15A & P52
Thru-bolted ends
Thru-bolted ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C14, Tapered spacer (in-line) (not-automatic)


One-sided tapered spacer (MC=T1SPA) (SN=F14A)
TNF=P15A & P52
Thru-bolted ends
Thru-bolted ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Two-sided tapered spacer (MC=T2SPA) (SN=F14B)

Plant Design System (PDS) Piping Component Data

87

Commodity Discussions
TNF=P15A & P52
Thru-bolted ends
Thru-bolted ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
The included angle of tapered spacers is determined by
the system from data in the design file and is supplied
to the component definition without need of user
intervention.

6Q2C15, Open spacer (in-line) (not-automatic)


Paddle spacer (MC=BLSPA) (SN=F13)
TNF=P15A & P52
Thru-bolted ends
Thru-bolted ends with integral gaskets
Full-face thru-bolted ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Open spacer (MC=OPSPA) (SN=F13)
TNF=P15A & P52
Thru-bolted ends
Thru-bolted ends with integral gaskets
Full-face thru-bolted ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C16, End (in-line) (not-automatic)


Any of the model codes for closure of a piping component may
be used under this AABBCC code. The piping materials classes
will only include the generic end which is applicable to the
vent/drain valve.

6Q2C17, Head (in-line) (not-automatic)


Hemispherical head (MC=HDHEMI) (SN=F17D)
TNF=P11A & P51
Beveled end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Ellipsoidal head (MC=HDELIP) (SN=F17D)
TNF=P11A & P51
Beveled end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
2:1 elliptical head (MC=HD21) (SN=F17D)

88

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P11A & P51
Beveled end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q2C19, Plug (in-line) (not-automatic)


Plug (MC=PLUG) (SN=F19)
TNF=P11A & P51
Male threaded end
Spigot end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C21, Cap (in-line) (not-automatic)


Cap (MC=CAPBV) (SN=F17D)
TNF=P11A & P51
Beveled end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Cap (MC=CAPOT) (SN=F19)
TNF=P15A & P52
Socket end
Socketwelded end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C23, Concentric diameter change (in-line)


Any of the model codes for concentric components that allow
diameter change may be used under this AABBCC code. This
component is used in the automatic placement of components.

6Q2C24, Eccentric diameter change (in-line) (not-automatic)


Any of the model codes for eccentric components that allow
diameter change may be used under this AABBCC code.

6Q2C25, Coupling-connector (in-line) (not-automatic)


Coupling/connector (MC=CPL) (SN=F25)
TNF=P11A & P51
Beveled ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

89

Commodity Discussions
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Female grooved ends
Push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A & P61
Flanged/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P25A & P61
Socket/male threaded ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P26A & P62
Socket/female threaded ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C26, Half coupling (in-line) (not-automatic)


Half coupling (MC=CPLH) (SN=F31)
TNF=P27A & P64
Plain/socket ends
Plain/socketwelded ends
Plain/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

90

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q2C27, Concentric reducer (in-line)


Concentric reducer (MC=REDC) (SN=F27)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="Value"
TNF=P26A & P62
Socket/socket ends
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P26A & P62
Mechanical joint/mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="Value"; Sc/Th="NREQD" or "Value"
TNF=P26A & P62
Push-on bell/push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P25A & P61
Mechanical joint/plain
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P25A & P61
Push-on bell/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P21A & P63
Beveled/beveled ends
Male grooved/male grooved ends
Male grooved/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P21A & P63
Plain/plain ends
For GCP: Rating="-"; Sc/Th="S-RAT"
For RCP: Rating="-"; Sc/Th="S-RAT"
TNF=P27A & P64
Plain/mechanical joint ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD" or "Value"

Plant Design System (PDS) Piping Component Data

91

Commodity Discussions
TNF=P27A & P64
Spigot/push-on bell ends
Plain/mechanical joint bell ends
Plain/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
A note is required on the iso to identify the end connection
sizes.

6Q2C28, Eccentric reducer (in-line) (not-automatic)


Eccentric reducer (MC=REDE) (SN=F28)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="Value"
TNF=P26A & P62
Mechanical joint/mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="Value"; Sc/Th="NREQD" or "Value"
TNF=P21A & P63
Beveled/beveled ends
Male grooved/male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
A note is required on the iso to identify the end connection
sizes and center line offset dimensions.

6Q2C32, Reducing coupling (in-line) (not-automatic)


Reducing coupling (MC=CPLR) (SN=F32)
TNF=P26A & P62
Socket/socket ends
Socketwelded/socketwelded ends
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

92

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q2C35, Concentric swage (in-line)


Concentric swage (MC=SWGC) (SN=F27)
TNF=P21A & P63
Beveled/beveled ends
Beveled/male threaded ends
Beveled/plain ends
Male threaded/male threaded ends
Male threaded/beveled ends
Male threaded/plain ends
Plain/plain ends
Plain ends/beveled ends
Plain ends/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
CP preparation for each end will generally be determined by
the piping commodities part of the Piping Job Specification.
Optionally, it is determined by the user during the
work session, provided that the end has been defined as "User
defined". A note is required on the iso to identify the end
connection sizes.

6Q2C36, Eccentric swage (in-line) (not-automatic)


Eccentric swage (MC=SWGE) (SN=F28)
TNF=P21A & P63
Beveled ends/beveled ends
Beveled/male threaded ends
Beveled/plain ends
Male threaded/male threaded ends
Male threaded/beveled ends
Male threaded/plain ends
Plain/plain ends
Plain ends/beveled ends
Plain ends/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
CP preparation for each end will generally be determined by
the piping commodities part of the Piping Job Specification.
Optionally, it is determined by the user during the
work session, provide that the end has been defined as "User
defined". A note is required on the iso to identify the end
connection sizes.

Plant Design System (PDS) Piping Component Data

93

Commodity Discussions

6Q2C39, Union (in-line) (not-automatic)


Union (MC=UN) (SN=F39)
TNF=P15A & P52
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C40, Orifice union (in-line) (not-automatic)


Orifice union (MC=UNO) (SN=F39)
TNF=P15A & P52
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C41, Dielectric union (in-line) (not-automatic)


Dielectric union (MC=UND) (SN=F39)
TNF=P15A & P52
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C43, Hose connection (in-line) (not-automatic)


Hose connection (MC=HC) (SN=F43_1)
TNF=P21A & P63
Male threaded/male hose ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P27A & P64
Male threaded/female quick connect ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P27A & P64
Male hose/female quick connect ends
Male hose/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

94

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q2C44, Bushing (in-line) (not-automatic)


Bushing (MC=BUSH) (SN=F43_2)
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="NONE"; Sc/Th="NREQD"

6Q2C46, Reducing insert (in-line) (not-automatic)


Reducing insert type 1 (MC=INSR1) (SN=F43_2)
TNF=P27A & P64
Plain/socket ends
Plain/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Reducing insert type 2 (MC=INSR2) (SN=F43_2)
TNF=P27A & P64
Plain/socket ends
Plain/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C47, Pipe bend (in-line)


Pipe bend w/ straight ends (MC=PIPB) (SN=F47A)
TNF=P11A
Beveled ends
Male threaded ends
Male grooved ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Pipe bend w/o straight ends (MC=PIPB2) (SN=F47A)
TNF=P11A
Beveled ends
Male threaded ends
Male grooved ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
The included angle of pipe bends is determined by the
system from data in the design file and is supplied to
the component definition without need of user intervention.

Plant Design System (PDS) Piping Component Data

95

Commodity Discussions
The radius of the pipe bend is defined in the "Mod"
column of the Piping Job Specification in terms of the
nominal diameter.
Dimension tables with TNF=P11A are required for all pipe
bends, regardless of their model code. In these tables, a
"-" is shown for the surface area and water weight
parameters since they are calculated by the software
using the information available for plain piping. For pipe
bends with model code PIPB, values are provided for
table parameters "P1" and "P2" to define the lengths of the
straight sections involved. For pipe bends with model code
PIPB2, dashes are provided for table parameters "P1" and
"P2" since no straight sections are involved. The use of
tables with TNF=51 will not be required for pipe bends since
their empty weights are calculated by the software
using the information available for plain piping.

6Q2C49, 5.625 deg elbow (in-line) (not-automatic)


5.625 deg elbow (MC=E5) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C51, 11.25 deg elbow (in-line) (not-automatic)


11.25 deg elbow (MC=E11) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"

96

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P11A & P51
Male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C53, 22.5 deg elbow (in-line) (not-automatic)


22.5 deg elbow (MC=E22) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P11A & P51
Male grooved ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C55, <45 deg direction change (in-line)


For an intersection more acute than 45 degrees, any of the
model codes for a 45 degree "trimmable elbow" or for a
"miter" may be used under this AABBCC code. This component
is used in the automatic placement of components.

Plant Design System (PDS) Piping Component Data

97

Commodity Discussions

6Q2C56, 45 deg direction change (in-line)


Any of the model codes for components that allow a 45 degree
change in direction may be used under this AABBCC code.
This component is used in the automatic placement of
components.

6Q2C57, 45 deg elbow (in-line)


45 deg elbow (MC=E45) (SN=F47)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P26A & P62
Flanged/socket ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P11A & P51
Male grooved ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
Plain/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

98

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P27A & P64
Plain/socket ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C59, 45 deg LR elbow (in-line)


45 deg LR elbow (MC=E45LR) (SN=F47)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
45 deg trimmable LR elbow (MC=E45TLR) (SN=F47)
TNF=Use tables for E45LR
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Model code E45TLR is trimmed by the software to the
angle defined in the design file between elements defining
the center line routing of the segment or, if center line
routes do not exist, to the angle defined at placement
The system will use data tables for E45LR; tables specific
to E45TLR will not be required.

6Q2C60, 45 deg long tangent elbow (in-line)


45 deg long tangent elbow (MC=E45LT) (SN=F63)
TNF=P27A & P64
Plain/push-on bell ends
Plain/mechanical joint bell ends
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

99

Commodity Discussions

6Q2C61, 45 deg 3D elbow (in-line)


45 deg 3D elbow (MC=E453D) (SN=F47)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
45 deg trimmable 3D elbow (MC=E45T3D) (SN=F47)
TNF=Use tables for E453D
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Model code E45T3D is trimmed by the software to the
angle defined in the design file between elements defining
the center line routing of the segment or, if center line
routes do not exist, to the angle defined at
placement time. The system will use data tables for E453D
tables specific to E45T3D will not be required.

6Q2C63, 45 deg union elbow (in-line) (not-automatic)


45 deg union elbow (MC=E45U) (SN=F63)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C65, 45 deg street elbow (in-line) (not-automatic)


45 deg street elbow (MC=E45ST) (SN=F63)
TNF=P21A & P63
Male grooved/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

100

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q2C66, 45 deg short elbow (in-line)


45 deg short elbow (MC=E45S) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C68, 45 deg long elbow (in-line)


45 deg long elbow (MC=E45L) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C73, 60 deg elbow (in-line) (not-automatic)


60 deg elbow (MC=E60) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C75, 45-90 deg direction change (in-line)


For an intersection larger than 45 degrees and smaller than
90 degrees, any of the model codes for a 90 degree
"trimmable elbow" or for a "miter" may be used under this
AABBCC code. This component is used in the automatic
placement of components.

Plant Design System (PDS) Piping Component Data

101

Commodity Discussions

6Q2C76, 90 deg direction change (in-line)


Any of the model codes for components that allow a 90 degree
change in direction may be used under this AABBCC code.
This component is used in the automatic placement of
components.

6Q2C77, 90 deg elbow (in-line)


90 deg elbow (MC=E90) (SN=F47)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P26A & P62
Flanged/socket ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P11A & P51
Male grooved ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Male grooved/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

102

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P27A & P64
Spigot/push-on bell ends
Plain/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P27A & P64
Plain/socket ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C79, 90 deg SR elbow (in-line)


90 deg SR elbow (MC=E90SR) (SN=F47)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q2C80, 90 deg LR elbow (in-line)


90 deg LR elbow (MC=E90LR) (SN=F47)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
90 deg trimmable LR elbow (MC=E90TLR) (SN=F47)
TNF=Use tables for E90LR
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Model code E90TLR is trimmed by the software to the angle
defined in the design file between elements defining the
center line routing of the segment or, if center line routes
do not exist, to the angle defined at placement. The system
will use data tables for E90LR; tables specific to E90TLR
will not be required.

Plant Design System (PDS) Piping Component Data

103

Commodity Discussions

6Q2C82, 90 deg LR long tangent elbow (in-line)


90 deg LR long tangent elbow (MC=E90LT) (SN=F63)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
Plain/push-on bell ends
Plain/mechanical joint bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C84, 90 deg reducing elbow (in-line)


90 deg reducing elbow (MC=E90R) (SN=F84)
TNF=P26A & P62
Socket/socket ends
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P21A & P63
Beveled/beveled ends
Male grooved/male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

6Q2C86, 90 deg 3D elbow (in-line)


90 deg 3D elbow (MC=E903D) (SN=F47)
TNF=P11A & P51
Beveled ends
Male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
90 deg trimmable 3D elbow (MC=E90T3D) (SN=F47)
TNF=Use tables for E903D
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

104

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Model code E90T3D is trimmed by the software to the
angle defined in the design file between elements defining
the center line routing of the segment or, if center line
routes do not exist, to the angle defined at placement.
The system will use data tables for E903D; tables specific
to E90T3D will not be required.

6Q2C88, 90 deg union elbow (in-line) (not-automatic)


90 deg union elbow (MC=E90U) (SN=F63)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C90, 90 deg street elbow (in-line) (not-automatic)


90 deg street elbow (MC=E90ST) (SN=F63)
TNF=P21A & P63
Male grooved/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q2C91, 90 deg reducing street elbow (in-line)


(not-automatic)
90 deg reducing street elbow (MC=E90RST) (SN=F84)
TNF=P25A & P61
Female threaded/male threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

105

Commodity Discussions

6Q2C93, 90 deg short elbow (in-line)


90 deg short elbow (MC=E90S) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q2C94, 90 deg long elbow (in-line)


90 deg long elbow (MC=E90L) (SN=F47)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

On-line Fittings (6P3C) and In-line Fittings (6Q3C)


The definition of piping fittings included in this paragraph is a continuation of that started under
piping component classes 6P2C and 6Q2C in Section C1.3.
The applicability of the above AABB codes is as defined below for each component type.
The AABBCC code for fittings will consist of the applicable AABB code, 6P3C or 6Q3C, followed
by two numbers for the specific type.
The Piping Component Model Entity and the Piping Component Analysis Entity will apply to these
classes of piping components.

See Also
Connect Point Data_Independent Variables (on page 107)
6Q3C01, 180 deg return (in-line) (not-automatic) (on page 112)
6Q3C03, 180 deg SR return (in-line) (not-automatic) (on page 112)
6Q3C05, 180 deg LR return (in-line) (not-automatic) (on page 112)
6Q3C07, 180 deg close return (in-line) (not-automatic) (on page 112)
6Q3C08, 180 deg medium return (in-line) (not-automatic) (on page 113)
6Q3C09, 180 deg open return (in-line) (not-automatic) (on page 113)
6Q3C14, Miter (in-line) (not-automatic) (on page 113)
6Q3C16, 45 deg miter (in-line) (on page 114)
6Q3C18, 90 deg miter (in-line) (on page 115)
6Q3C22, Tee (in-line) (on page 116)
6Q3C24, Reducing branch tee (in-line) (on page 117)
6Q3C25, Reducing run and branch tee (in-line) (on page 119)
6Q3C27, On-run union tee (in-line) (not-automatic) (on page 119)
6Q3C28, On-branch union tee (in-line) (not-automatic) (on page 119)
6Q3C31, Street tee (in-line) (not-automatic) (on page 120)
6Q3C34, Reducing instrument tee (in-line) (not-automatic) (on page 120)
6Q3C36, Drip ring tee (in-line) (not-automatic) (on page 120)
6Q3C38, Basin tee (in-line) (on page 121)
6Q3C45, True Y (in-line) (not-automatic) (on page 121)
6Q3C47, Lateral (in-line) (on page 121)
6Q3C49, Reducing branch lateral (in-line) (on page 122)
6Q3C50, Reducing run and branch lateral (in-line) (on page 123)

106

Plant Design System (PDS) Piping Component Data

Commodity Discussions
6Q3C52, 90 deg short Y-branch (in-line) (not-automatic) (on page 123)
6Q3C53, 90 deg reducing short Y-branch (in-line) (not-automatic) (on page 123)
6Q3C54, 90 deg long Y-branch (in-line) (not-automatic) (on page 123)
6Q3C55, 90 deg reducing long Y-branch (in-line) (not-automatic) (on page 124)
6Q3C60, Cross (in-line) (not-automatic) (on page 124)
6Q3C62, Reducing branches cross (in-line) (not-automatic) (on page 125)
6Q3C63, Reducing run and branches cross (in-line) (not-automatic) (on page 125)
6Q3C64, Basin cross (in-line) (not-automatic) (on page 126)
6Q3C70, Saddle (in-line) (on page 126)
6Q3C72, Sweepolet (in-line) (on page 126)
6Q3C73, Weldolet (in-line) (on page 127)
6Q3C74, Sockolet (in-line) (on page 127)
6Q3C75, Thredolet (in-line) (on page 128)
6Q3C76, Nippolet (in-line) (on page 128)
6Q3C77, Elbolet (in-line) (not-automatic) (on page 129)
6Q3C78, Latrolet (in-line) (not-automatic) (on page 129)
6Q3C79, Endolet (in-line) (not-automatic) (on page 130)
6Q3C80, Reinforcing pad (in-line) (on page 130)
6Q3C82, Reinforcing weld (in-line) (on page 132)
6Q3C84, Buttweld (in-line) (not-automatic) (on page 134)
6Q3C88, Branch nipple (in-line) (not-automatic) (on page 134)
6Q3C89, In-line nipple (in-line) (not-automatic) (on page 135)
6Q3C95, Gasket (on page 135)
6Q3C97, Stud (on page 137)

Connect Point Data_Independent Variables


For each component in the piping commodities part of the Piping Job Specification, component
specific data is defined in tables, as follows:

Green Connect Point Data Only, GCP=Male


If only green connect point data appears in the definition of the component in the piping
commodities part of the Piping Job Specification and if the connect point is a male termination
type, the following applies:
General data about the component is included in a table with format P11A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, weight of water plus all those
dimensional parameters required to display the component in the model whose values are not
defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P11B.
The name of the P11B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_B
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the component in the model that were not included in the P11A table.

Plant Design System (PDS) Piping Component Data

107

Commodity Discussions

The empty weight of the component is included in a table with format P51. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Sc/Th(G)_WC
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the component.

Green Connect Point Data Only, GCP Male


If only green connect point data appears in the definition of the component in the Piping Job
Specification and if the connect point is not a male termination type, the following applies:
General data about the component is included in a table with format P15A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) Rat(G) A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, weight of water plus all those
dimensional parameters required to display the component in the model whose values are not
defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P15B.
The name of the P15B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G) Rat(G) B

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the component in the model that were not included in the P15A table.
The empty weight of the component is included in a table with format P52. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Sc/Th(G)_WC
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the component.

Green and Red Connect Point Data, GCP Male, RCP=Male


If both green and red connect point data appear in the definition of the component in the Piping
Job Specification, the green connect point is not a male termination type and the red connect point
is a male termination type, the following applies:
General data about the component is included in a table with format P25A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P25B.

108

Plant Design System (PDS) Piping Component Data

Commodity Discussions
The name of the P25B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) Term(R)_B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P25A
table.
The empty weight of the component is included in a table with format P61. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Sc/Th(R)_WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP Male, RCP Male
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification and neither the green nor the red connect points are male termination types, the
following applies:
General data about the component is included in a table with format P26A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P26B.
The name of the P26B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P26A
table.
The empty weight of the component is included in a table with format P62. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Rat(G) Term(R) Rat(R) Sc/Th(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Plant Design System (PDS) Piping Component Data

109

Commodity Discussions
Green and Red Connect Point Data, GCP=Male, RCP=Male, MC WOL, SOL, TOL, NOL, EOL
or LOL
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification and both the green and the red connect points are male termination types and
the model code is not WOL, SOL, TOL, NOL, EOL or LOL, the following applies:
General data about the component is included in a table with format P21A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) Term(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P21B.
The name of the P21B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G) Term(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P21A
table.
The empty weight of the component is included in a table with format P63. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Sc/Th(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP=Male, RCP Male, MC WOL, SOL, TOL, NOL,
EOL or LOL
If both green and red connect point data appear in the definition of the component in the piping
commodities part of the Piping Job Specification, the green connect point is a male termination
type, the red connect point is not a male termination type and the model code is not WOL, SOL,
TOL, NOL, EOL or LOL, the following applies:
General data about the component is included in a table with format P27A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Term(R) Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P27B.
The name of the P27B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:

110

Plant Design System (PDS) Piping Component Data

Commodity Discussions
MC_GS_Term(G) Term(R) Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P27A
table.
The empty weight of the component is included in a table with format P64. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP=Male, RCP=Male or Female, MC=WOL, SOL, TOL,
NOL, EOL or LOL
If both green and red connect point data appear in the definition of the component in the Piping
Job Specification, the green connect point is a male termination type, the red connect point is
either a male or a female termination type and the model code is WOL, SOL, TOL, NOL, EOL or
LOL, the following applies:
General data about the component is included in a table with format P28A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat/Sc/Th(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P28B.
The name of the P28B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat/Sc/Th(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P28A
table.
The empty weight of the component is included in a table with format P65. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat/Sc/Th(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.
Unless otherwise indicated, all fittings are automatically placed in the Piping Task during
automatic component placement. Components to be placed automatically by the system will
be selected to match the CP preparation, CP rating and table suffix of the applicable CP of the
mating component or equipment nozzle.
Under the description of each table format applicable to each component type, the GCP and
RCP rating and schedule/thickness that needs to be provided in the Piping Job Specification

Plant Design System (PDS) Piping Component Data

111

Commodity Discussions

has been listed. These values are required for one or more of the reasons indicated below and
will not necessarily be part of the names of the tables that include data about the component.
To procure the component.
To access data tables. Refer to Section 4, Model Graphics Definitions, for a description of
the table formats.
To supply data required for stress analysis purposes.
The AABBCC code for fittings will consist of the applicable AABB code, 6P3C or 6Q3C,
followed by two numbers for the specific type.
AABBCC
Description

6Q3C01, 180 deg return (in-line) (not-automatic)


180 deg return (MC=R180) (SN=F101)
TNF=P15A & P52
Socket ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q3C03, 180 deg SR return (in-line) (not-automatic)


180 deg SR return (MC=R180SR) (SN=F101)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q3C05, 180 deg LR return (in-line) (not-automatic)


180 deg LR return (MC=R180LR) (SN=F101)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q3C07, 180 deg close return (in-line) (not-automatic)


180 deg close return (MC=R180CL) (SN=F101)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

112

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C08, 180 deg medium return (in-line) (not-automatic)


180 deg medium return (MC=R180MD) (SN=F101)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q3C09, 180 deg open return (in-line) (not-automatic)


180 deg open return (MC=R180OP) (SN=F101)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q3C14, Miter (in-line) (not-automatic)


1 cut miter (MC=M1) (SN=F114A)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
2 cuts miter (MC=M2) (SN=F114B)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
3 cuts miter (MC=M3) (SN=F114C)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

113

Commodity Discussions
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
4 cuts miter (MC=M4) (SN=F114D)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
The same nominal diameter must apply to both ends of these
miters.
The miter angle of these miters is determined by the
system from data in the design file and is supplied to
the component definition without need of user intervention.
The number of cuts in a miter will have to be "remembered"
by the system since this value is required in the
calculation of SIF applicable to the miter.

6Q3C16, 45 deg miter (in-line)


1 cut 45 deg miter (MC=M451) (SN=F114A)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Plain/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
2 cuts 45 deg miter (MC=M452) (SN=F114B)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

114

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
The same nominal diameter must apply to both ends of these
miters. The number of cuts in a miter will have to be
"remembered" by the system since this value is required
in the calculation of SIF applicable to the miter.

6Q3C18, 90 deg miter (in-line)


1 cut 90 deg miter (MC=M901) (SN=F114A)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
2 cuts 90 deg miter (MC=M902) (SN=F114B)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Plain/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
3 cuts 90 deg miter (MC=M903) (SN=F114C)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
4 cuts 90 deg miter (MC=M904) (SN=F114D)

Plant Design System (PDS) Piping Component Data

115

Commodity Discussions
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
The same nominal diameter must apply to both ends of these
miters. The number of cuts in a miter will have to be
"remembered" by the system since this value is required
in the calculation of SIF applicable to the miter.

6Q3C22, Tee (in-line)


Tee (MC=T) (SN=F122_1)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Socket ends
Socketwelded ends
Female threaded ends
Mechanical joint bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Push-on bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A & P62
Flanged/socket ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"

116

Plant Design System (PDS) Piping Component Data

Commodity Discussions
TNF=P25A & P61
Socket/male threaded ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P11A & P51
Beveled ends
Male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Male grooved/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Trimmable branch tee (MC=TBT) (SN=F122_1)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
The branch end of model code TBT is trimmed by the
software to the angle defined in the design file between the
segment run connected to the branch end of the component and
that connected to either header end of the component. The
placement of this component will not be automatic. The user
will first insert the component in the header and then continue
piping from CP3. The system will use data tables for T;
tables specific to TBT will not be required.

6Q3C24, Reducing branch tee (in-line)


Reducing branch tee (MC=TRB) (SN=F122_1)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="Value"
TNF=P26A & P62
Socket/socket ends
Socketwelded/socketwelded ends
Female threaded/female threaded ends
Mechanical joint bell/mechanical joint bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

117

Commodity Discussions
TNF=P26A & P62
Mechanical joint/mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="Value"; Sc/Th="NREQD" or "Value"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P21A & P63
Beveled/beveled ends
Male grooved/male grooved ends
Male grooved/male threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Socket/male threaded ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Trimmable reducing branch tee (MC=TRBT) (SN=F122_1)
TNF=P11A & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
The branch end of model code TRBT is trimmed by the
software to the angle defined in the design file between the
segment run connected to the branch end of the component and
that connected to either header end of the component. The
placement of this component will not be automatic. The user
will first insert it in the header and then continue
piping from CP3. The system will use data tables for TRB;
tables specific to TRBT will not be required.

118

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C25, Reducing run and branch tee (in-line)


Reducing run and branch tee (MC=TRRB) (SN=F125)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P26A & P62
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
It will only be possible to place components with two
different sizes.

6Q3C27, On-run union tee (in-line) (not-automatic)


On-run union tee (MC=TUOR) (SN=F127)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q3C28, On-branch union tee (in-line) (not-automatic)


On-branch union tee (MC=TUOB) (SN=F128)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

119

Commodity Discussions

6Q3C31, Street tee (in-line) (not-automatic)


Street tee (MC=TST) (SN=F122_2)
TNF=P27A & P64
Male threaded/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q3C34, Reducing instrument tee (in-line) (not-automatic)


Reducing instrument tee (MC=TRIF) (SN=F134M)
TNF=P26A & P62
Thru-bolted/flanged ends
Thru-bolted/flanged ends with integral gaskets
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q3C36, Drip ring tee (in-line) (not-automatic)


Drip ring tee w/0.5inch threaded taps (MC=TDRA) (SN=F134)
TNF=P15A & P52
Thru-bolted/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="-"
Drip ring tee w/0.5inch socketwelded taps (MC=TDRAW)
(SN=F134)
TNF=P15A & P52
Thru-bolted/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD-"
For RCP: Rating="Value"; Sc/Th="-"
Drip ring tee w/0.75inch threaded taps (MC=TDRB) (SN=F134)
TNF=P15A & P52
Thru-bolted/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="-"
Drip ring tee w/0.75inch socketwelded taps (MC=TDRBW)
(SN=F134)
TNF=P15A & P52
Thru-bolted/socketwelded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="-"
The following comments apply to the above items:

120

Plant Design System (PDS) Piping Component Data

Commodity Discussions
o The number of taps, up to 4, is defined in the "Mod"
column of the Piping Job Specification.

6Q3C38, Basin tee (in-line)


Basin tee (MC=TBA) (SN=F122_1)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q3C45, True Y (in-line) (not-automatic)


True Y (MC=Y) (SN=F145)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A & P51
Beveled ends
Male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q3C47, Lateral (in-line)


Lateral (MC=L) (SN=F147)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Socket ends
Socketwelded ends
Female threaded ends
Mechanical joint bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

121

Commodity Discussions
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P11A & P51
Beveled ends
Male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
Plain/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q3C49, Reducing branch lateral (in-line)


Reducing branch lateral (MC=LRB) (SN=F147)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="Value"
TNF=P26A & P62
Socketwelded/socketwelded ends
Female threaded/female threaded ends
Mechanical joint bell/mechanical joint bell ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P26A & P62
Mechanical joint/mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="Value"; Sc/Th="NREQD" or "Value"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P21A & P63
Beveled/beveled ends
Male grooved/male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

122

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C50, Reducing run and branch lateral (in-line)


Reducing run and branch lateral (MC=LRRB) (SN=F150)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
It will only be possible to place components with two
different sizes.

6Q3C52, 90 deg short Y-branch (in-line) (not-automatic)


90 deg short Y-branch (MC=S90YB) (SN=F152)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q3C53, 90 deg reducing short Y-branch (in-line)


(not-automatic)
90 deg reducing short Y-branch (MC=S90YRB) (SN=F152)
TNF=P26A & P62
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q3C54, 90 deg long Y-branch (in-line) (not-automatic)


90 deg long Y-branch (MC=L90YB) (SN=F154)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A & P51
Male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

123

Commodity Discussions

6Q3C55, 90 deg reducing long Y-branch (in-line)


(not-automatic)
90 deg reducing long Y-branch (MC=L90YRB) (SN=F154)
TNF=P26A & P62
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P21A & P63
Male grooved/male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

6Q3C60, Cross (in-line) (not-automatic)


Cross (MC=X) (SN=F160)
TNF=P15A & P52
Flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Socket ends
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P15A & P52
Mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P11A & P51
Beveled ends
Male grooved ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

124

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C62, Reducing branches cross (in-line) (not-automatic)


Reducing branches cross (MC=XRB) (SN=F160)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="Value"
TNF=P26A & P62
Socketwelded/socketwelded ends
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P26A & P62
Mechanical joint/mechanical joint ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="Value"; Sc/Th="NREQD" or "Value"
TNF=P25A & P61
Mechanical joint/plain ends
For GCP: Rating="Value"; Sc/Th="NREQD" or "Value"
For RCP: Rating="-"; Sc/Th="NREQD"
TNF=P21A & P63
Beveled/beveled ends
Male grooved/male grooved ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
TNF=P27A & P64
Spigot/push-on bell ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
It will only be possible to place components with two
different sizes.

6Q3C63, Reducing run and branches cross (in-line)


(not-automatic)
Reducing run and branches cross (MC=XRRB) (SN=F163)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

125

Commodity Discussions
TNF=P26A & P62
Socketwelded/socketwelded ends
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
It will only be possible to place components with two
different sizes.

6Q3C64, Basin cross (in-line) (not-automatic)


Basin cross (MC=XBA) (SN=F160)
TNF=P15A & P52
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q3C70, Saddle (in-line)


Saddle (MC=SAD) (SN=F170)
TNF=P21A & P63
Plain/plain ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"

6Q3C72, Sweepolet (in-line)


Sweepolet (MC=SWOL) (SN=F172)
TNF=P28A & P65
Beveled/beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software, regardless
of the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

126

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C73, Weldolet (in-line)


Weldolet (MC=WOL) (SN=F173)
TNF=P28A & P65
Beveled/beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
In determining the "L" dimension for dimension tables for
weldolets =<2 inch NPD (related to "A" dimension in Bonney
Forge catalog) will only depend on the size and thickness of
the outlet and is independent of the thickness of the
header.
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software, regardless
of the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

6Q3C74, Sockolet (in-line)


Sockolet (MC=SOL) (SN=F173)
TNF=P28A & P65
Beveled/socketwelded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software, regardless
of the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

Plant Design System (PDS) Piping Component Data

127

Commodity Discussions

6Q3C75, Thredolet (in-line)


Thredolet (MC=TOL) (SN=F173)
TNF=P28A & P65
Beveled/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software, regardless
of the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

6Q3C76, Nippolet (in-line)


Nippolet (MC=NOL) (SN=F176)
TNF=P28A & P65
Beveled/male threaded ends
Beveled/plain ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"
The length of the nippolet is defined in the "Mod"
column of the Piping Job Specification.
Surface areas and weights for nippolets are based on 4.5
inch length.
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software, regardless
of the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

128

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C77, Elbolet (in-line) (not-automatic)


Elbolet for LR elbow (MC=EOLLR) (SN=F177)
TNF=P28A & P65
Beveled/beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
Beveled/socketwelded ends
Beveled/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Elbolet for SR elbow (MC=EOLSR) (SN=F177)
TNF=P28A & P65
Beveled/beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
Beveled/socketwelded ends
Beveled/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP1 of this
component to the centerline of the elbow is reported as
"RIGID" to the Pipe Stress Analysis software, regardless of
the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

6Q3C78, Latrolet (in-line) (not-automatic)


Latrolet (MC=LOL) (SN=F178)
TNF=P28A & P65
Beveled/beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
Beveled/socketwelded ends
Beveled/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
In determining the "L" dimension for dimension tables for
weldolets =<2 inch NPD (related to "A" dimension in Bonney
Forge catalog) will only depend on the size and thickness of
the outlet and is independent of the thickness of the
header.

Plant Design System (PDS) Piping Component Data

129

Commodity Discussions
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software, regardless
of the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

6Q3C79, Endolet (in-line) (not-automatic)


Flatolet on head/cap (MC=FOLHC) (SN=F179)
TNF=P28A & P65
Beveled/beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
Beveled/socketwelded ends
Beveled/female threaded ends
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software, regardless
of the value in the Piping Job Specification so as not to
provide a fictitious flexibility.

6Q3C80, Reinforcing pad (in-line)


Stub-on reinforcing pad (MC=RPAD) (SN=F180)
TNF=P29A & None
Plain/plain ends
For GCP: Rating="-"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"
This model code represents a "stub-on" reinforcing pad; that
is one in which the pipe terminates at the outside surface
of the header.
Stub-in reinforcing pad (MC=RPAD2) (SN=F180)
TNF=P29A & None
Plain/plain ends
For GCP: Rating="-"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"

130

Plant Design System (PDS) Piping Component Data

Commodity Discussions
This model code represents a "stub-in" reinforcing pad; that
is one in which the pipe terminates at the inside surface of
the header.
The following comments apply to all reinforcing pads:
o Reinforcing pads are defined in the piping materials
classes to have an actual value for fabrication category,
which may be changed after placement. In the isometric
drawings, a note will not be placed in the graphic part
of the drawing to show their size. A short description
has been prepared for reinforcing pads and is displayed
in the bill of materials.
o Reinforcing pads may be placed with either single or
double curvature, for example reinforcing a pipe or a head
respectively.
o The angle of intersection between the header and the
branch is part of the table name containing
dimensional parameters for the component. This angle will
be derived by the system from data in the design file.
Four different types of intersection is recognized:
- Intersections at angles equal to or greater than 20 but
less than 45 degrees: the number "2045" is used as
part of the table name.
- Intersections at 45 degrees: the number "45" is
used as part of the table name.
- Intersections at angles greater than 45 but lesser than
90 degrees: the number "4590" is used as part of
the table name.
- Intersections at 90 degrees: the number "90" is
used as part of the table name.
o Two possibilities exist regarding dimensions for a
reinforcing pad:
- If a "0" is entered in the "MOD" column of the Piping
Job Specification, dimensions are to be derived from
either a data table and/or from branch calculations.
For the case where no branch calculation is involved,
both the pad width and pad thickness are included in
the applicable dimension table. If a branch calculation
is involved, a value is provided in the dimension
table for pad width and either a "-" or value for pad
thickness. See section titled "Choosing a Branch
Connection from a Branches Table" for details.
- If a "1" is entered in such column, the system is to
prompt for dimensions. If dimensions are provided by
the user, their values are stored in the TDB so that in
subsequent recreations of the piping system, those
values and not those that might exist in a data table
are used by the system.

Plant Design System (PDS) Piping Component Data

131

Commodity Discussions
o Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
o The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software,
regardless of the value in the Piping Job Specification so
as not to provide a fictitious flexibility.
o The empty weight of these components is neglected.

6Q3C82, Reinforcing weld (in-line)


Stub-on reinforcing weld (MC=RWELD) (SN=F182)
TNF=P29A & None
Beveled ends
For GCP: Rating="-"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"
This model code represents a "stub-on" reinforcing weld;
that is one in which the pipe terminates at the outside
surface of the header.
Stub-in reinforcing weld (MC=RWELD2) (SN=F182)
TNF=P29A & None
Beveled ends
For GCP: Rating="-"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"
This model code represents a "stub-in" reinforcing weld;
that is one in which the pipe terminates at the inside
surface of the header.
The following comments apply to all reinforcing welds:
o Reinforcing welds are defined in the piping materials
classes to have a fabrication category of "-" since for
them it is not possible to define this attribute. In the
isometric drawings, a note is placed in the graphic
part of the drawing to show their size. A short
description has been prepared for reinforcing welds. The
option not to display reinforcing welds in the bill of
materials is chosen, however, in the ISOGEN options
file.
o Reinforcing welds may be placed with either single or
double curvature, for example reinforcing a pipe or a head
respectively.

132

Plant Design System (PDS) Piping Component Data

Commodity Discussions
o The angle of intersection between the header and the
branch is part of the table name containing
dimensional parameters for the component. This angle will
be derived by the system from data in the design file.
Four different types of intersection is recognized:
- Intersections at angles equal to or greater than 20 but
less than 45 degrees: the number "2045" is used as
part of the table name.
- Intersections at 45 degrees: the number "45" is
used as part of the table name.
- Intersections at angles greater than 45 but lesser than
90 degrees: the number "4590" is used as part of
the table name.
- Intersections at 90 degrees: the number "90" is
used as part of the table name.
o Two possibilities exist regarding dimensions for a
reinforcing weld:
- If a "0" is entered in the "MOD" column of the Piping
Job Specification, dimensions are to be derived from
either a data table and/or from branch calculations.
For either case, a value is provided for the
reinforcing weld size in the applicable dimension table.
See section titled "Choosing a Branch Connection from a
Branches Table" for details.
- If a "1" is entered in such column, the system is to
prompt for dimensions. If dimensions are provided by
the user, their values are stored in the TDB so that in
subsequent recreations of the piping system, those values
and not those that might exist in a data table are used
by the system.
o Data defined for these components will allow the system to
determine the applicable stress intensification factors
(SIF) to be used in stress analysis of the piping system.
o The thickness of the portion of piping from PCP2 of this
component to the centerline of the header is reported
as "RIGID" to the Pipe Stress Analysis software,
regardless of the value in the Piping Job Specification so
as not to provide a fictitious flexibility.
o The empty weight of these components is neglected.

Plant Design System (PDS) Piping Component Data

133

Commodity Discussions

6Q3C84, Buttweld (in-line) (not-automatic)


Buttweld, English units (MC=BWELD) (SN=F184)
TNF=None & P51
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
Buttweld, metric units (MC=BWELD2) (SN=F184)
Buttweld, mixed units (MC=BWELD3) (SN=F184)

6Q3C86, Full Encirclement Reinforcement Pad (In-Line)


Stub-on Full Encirclement Reinforcement Pad (MC=RPADF) (SN=F180F)
TNF=P29A & None
Plain/plain ends
For GCP: Rating="-"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"
This model code represents a "stub-on" reinforcing pad; that is
one in which the pipe terminates at the outside surface of the header pipe.

6Q3C88, Branch nipple (in-line) (not-automatic)


Branch nipple (MC=NIP) (SN=F188)
TNF=P11A & P51
Male threaded ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Male threaded/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
The length of the branch nipple is defined in the "Mod"
column of the Piping Job Specification.
Surface areas and weights for branch nipples are based
on 4 inch length.

134

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C89, In-line nipple (in-line) (not-automatic)


In-line nipple (MC=NIPIL) (SN=F188)
TNF=P11A & P51
Male threaded ends
Plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P21A & P63
Male threaded/plain ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"
The length of the in-line nipple is defined in the
"Mod" column of the Piping Job Specification.
Surface areas and weights for in-line nipples are based
on 4 inch length.

6Q3C95, Gasket
There is no model code for this piping component. It is only required in the piping materials class
for piping materials purposes.
TNF=None & None
For GCP: Rating="Value"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"
Gaskets are handled as follows:
At a bolted joint, bolted ends may be either thru-bolted or non-thru-bolted. Requirements
defined below apply to both thru-bolted and non-thru-bolted ends unless specifically indicated
otherwise.
A gasket entry is required for every combination of diameter, preparation, rating and table
suffix of nozzles, commodity components and/or specialty components to which the piping
materials class applies. For example, to account for a bolted joint including an orifice flange
and an orifice plate, two gasket entries must be defined: one with TS=29 for the orifice flange
end and the other one with TS-5 for the orifice plate end.
The definition of each gasket entry in the piping materials class will include values for each of
the parameters listed below.
AABBCC code: the value 6Q3C95 will always apply.
Option:: the value "1" will apply unless a different option value is defined as an override as
part of the placement of the commodity or specialty component for which the gasket is
intended.
GCP from-to: these entries will define the ranges of nominal diameters for which the
gasket is intended.
GCP preparation: these entries will define the end preparation for which the gasket is
intended. Gasket definitions should not be made for end preparations implying integral
gaskets. For a piping materials class in which all gaskets are integral, the gasket gap in
the Piping Job Specification table is defined as "0".
GCP rating: these entries will define the pressure rating for which the gasket is intended.
For this definition, the values of rating must omit characters such as "CL", "#" and "OT"

Plant Design System (PDS) Piping Component Data

135

Commodity Discussions
even if these were used in the definition of the component to which the gasket will
correspond.
GCP table suffix: these entries will define the table suffix for which the gasket is intended.
Commodity code
TMx: this represents the maximum temperature for which use of the gasket is allowed. It
will also provide one of the search keys for the value of gasket gap in the Gasket Gaps
Table.
Geometry standard: the entry of a value for this parameter is optional. It has been entered
in the piping materials classes to assist the user in interpreting the definition of the gasket.
Mod: this attribute allows the definition of the compressed gasket thickness or other
gasket parameter that is required to procure the gasket.
Material grade: the entry of a value for this parameter is optional. It has been entered in
the piping materials classes to assist the user in interpreting the definition of the gasket.
Fabrication class: these entries will define the disposition that is made of the gasket for
material reporting and isometric purposes.
The default selection of a gasket is based upon option "1". If the user wishes to use a gasket at a
joint other than the default, he could do so by overriding during placement of a commodity or
specialty component the gasket override option that is to apply for gasket selection. The value of
this override option will apply to all the connect points of all bolted ends placed as part of
thatplacement operation. If one of the bolted ends to be placed is to mate a previously placed end
which has a different gasket override option, placement of the component will fail. The gasket gap
that will apply to the override gasket is determined by the system from a gasket gap table in a
manner analogous to that used for the default gaskets. During automatic component placement,
bolted ends added by the system to mate existing ends will inherit the values of gasket override
option that apply to the previously placed ends. During model reconstruction, the system will
respect the gasket override option defined during previous placements.
Two possibilities exist regarding gasket selection depending upon the value for end
preparation of the components at the bolted joint:
If one or both of the ends at the bolted joint has an end preparation indicating that an
integral gasket applies, no gasket is returned by the system.
If none of the ends at the bolted joint has an end preparation indicating that an integral
gasket applies, the system will proceed as follows:
The system will select for each bolted end in a bolted joint, from the piping materials
class, the gasket to use on the basis of the functional capability described under the
heading "Choosing Gasket at Bolted End".
After all gaskets are so determined at a bolted joint, the system will compare the
commodity codes and modifiers of mating ends. If they are identical, the gasket
selection is deemed to be successful; if not identical a fatal error is reported.
At the a bolted joint, regardless of the number of ends involved at the joint and of the design
volumes in which they might be found, the default ownership for all gaskets and studs required
by the joint is assigned by the system to the first non-thru-bolted end found by the system
during the gasket selection process. This characteristic only affects the ownership of such
gaskets and studs. The gasket selection itself is based on the criteria given in preceding
paragraphs and not on the properties of the first bolted end encountered by the system. If a
user needs to assign the ownership of gaskets and studs for the joint to a particular bolted end,
he may do so by setting the value of the applicable user-data attribute for the applicable
connect point to either "Default Gasket/Bolts/Nuts Ownership" or "Gasket/Bolts/Nuts Owned
by this Component". As was the case for the default ownership, this attribute only controls in
which isometric drawing the gaskets and studs are listed and not their selection basis.

136

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q3C97, Stud
There is no model code for this piping component. It is only required in the piping materials class
for piping materials purposes.
TNF=None & None
For GCP: Rating="Value"; Sc/Th="-"
For RCP: Rating="Value"; Sc/Th="-"
Studs are handled by the system as follows:
At a bolted joint, bolted ends may be either thru-bolted (with or without bolt holes) or
non-thru-bolted. Requirements defined below apply to both thru-bolted and non-thru-bolted
ends unless specifically indicated otherwise.

Users can specify whether thru-bolted ends include bolt holes or not. This distinction
does not affect the handling of studs in PDS, but it does affect pressure rating design checks
and flange placement. For more information, refer to the Piping Design Graphics Reference
Guide and the Reference Data Manager Reference Guide.
The definition of each stud entry in the piping materials class will include values for each of the
parameters listed below.
A stud entry is required for every combination of nominal diameter, preparation (only if the
RDB option that involves CP termination for bolt length calculations is active) and rating of
nozzles, commodity components and/or specialty components to which the piping
materials class applies.
AABBCC code: the value 6Q3C97 will always apply.
Option:: the value "1" will always apply.
GCP from-to: these entries will define the ranges of nominal diameter of the
non-thru-bolted ends of the bolted joint for which the stud is intended. Only data for the
GCP is provided regardless of whether the stud is intended for non-thru-bolted ends with
identical preparation and/or ratings or not.
GCP and RCP preparation: these entries will define the preparation of the non-thru-bolted
ends of the bolted joint for which the stud is intended. Two possibilities exist:
The stud is intended for non-thru-bolted ends with identical preparations and rating,
the value of the preparation will only be included in the GCP preparation column; a "-"
is included for the RCP preparation.
The stud is intended for mating bolted ends with different either preparation or rating:
the properties of the end(s) with the lowest codelist number defining its CP
preparation, regardless of the values for rating, is defined under the GCP data.
GCP and RCP rating: these entries will define the pressure rating of the non-thru-bolted
ends of the bolted joint for which the stud is intended. For this definition, the values of
rating must omit characters such as "CL", "#" and "OT" even if these were used in the
definition of the component to which the stud will correspond. The following possibilities
exist:
The stud is intended for non-thru-bolted ends with identical preparations and ratings:
the value of the rating will only be included in the GCP rating column; a "-" is included
for the RCP rating.
The stud is intended for mating bolted ends with identical preparations but different
ratings: the value of the stronger rating is included in the GCP rating column; the
value of the weaker rating is included in the RCP rating column. This situation is
commonly found, for example, due to equipment nozzle rating differing from that of
the mating piping component flange.

Plant Design System (PDS) Piping Component Data

137

Commodity Discussions

138

The stud is intended for mating bolted ends with different preparations and ratings:
the properties of the end(s) with the lowest codelist number defining its CP
preparation is defined under the GCP data.
Commodity code: a different commodity code is assigned, for example, to:
Studs which are always lubricated.
Studs which are only lubricated when they exceed a given bolt diameter.
Studs which are never lubricated.
TMx: this represents the maximum temperature at which use of the stud is allowed.
Geometry standard: the entry of a value for this parameter is optional. It has been
entered in the piping materials classes to assist the user in interpreting the definition of the
stud.
Mod: the following characteristics apply:
The sign used for this attribute defines whether a stud (+ or no sign) or a machine bolt
(-) is involved.
The value "0" defines studs that will use nuts of standard nut allowance. The value
"1" defines machine bolts that will use nuts of standard nut allowance. Values "2"
through "5" define either studs (+ or no sign) or machine bolts (-) that use special nut
allowances.
Material grade: the entry of a value for this parameter is optional. It has been entered in
the piping materials classes to assist the user in interpreting the definition of the stud.
Fabrication class: these entries will define the disposition that is made of the stud for
material reporting and isometric purposes.
The system will select, from the piping materials class of the end that owns the joint, the stud
to use and its applicable data on the basis of the functional capability described under the
heading "Choosing Stud at Bolted Joint".
The system will access for each non-thru-bolted end in a bolted joint the applicable of the
tables described below.
STUD_Rat_TS, if the RDB option that involves CP termination for bolt length calculations
is not active (in the WS software, the 'almost precise' value applies to the corresponding
toggle switch); or
STUD_Term_Rat_TS, if the RDB option that involves CP termination for bolt length
calculations is active (in the WS software, the 'precise' value applies to the corresponding
toggle switch).
To determine the number and diameter of bolts required and the nut allowance to be used.
The system will use the termination type (only if the RDB option that involves CP termination
for bolt length calculations is active), rating and table suffix of the applicable bolted end to
select the stud table to use. No similar access to a stud table is made for the thru-bolted ends
of the joint. If identical values for number and diameter of bolts are derived from all the stud
tables that were accessed for the bolted joint, regardless of whether the bolted ends are in the
same or in different design volumes, the system will proceed. If different values are derived,
a fatal error is reported.
The value of nut allowance selected for each bolted end will depend upon the value of the
modifier parameter read in the piping materials class for the stud applicable to the joint. The
actual value of nut allowance selected for each non-thru-bolted ends of the bolted joint is used
in the determination of bolt length for the joint.
Both thru-bolted ends and non-thru-bolted ends will have a BLT_Term_Rat_TS tables
associated with them. Tables for non-thru-bolted ends will have actual values for bolt circle
diameter. Tables for thru-bolted ends will have dashes for bolt circle diameter. The system

Plant Design System (PDS) Piping Component Data

Commodity Discussions

will access for each non-thru-bolted end in the bolted joint the corresponding
BLT_Term_Rat_TS table to determine the bolt circle diameter that applies. If identical values
for bolt circle diameter are derived, the system will proceed. If different values are derived, a
fatal error is reported.
Stud and machine bolt lengths are calculated by the system as the sum of the following:
The values for all dimensions "R" derived from the applicable generic tables for all
non-thru-bolted ends involved in the bolted connection, plus
The values for all "face to face" dimensions stored in the TDB for all thru-bolted ends
involved in the bolted connection (it is essential that the value stored in the TDB for this
parameter truly be a face to face dimension and not a connect point to connect point
dimension), plus
The values for all gasket gaps involved in the bolted connection, plus
The total nut allowances, as defined below:
For studs: the sum of the nut allowances derived from the applicable of the tables
described below:
STUD_Rat_TS, if the RDB option that involves CP termination for bolt length
calculations is not active (in the WS software, the 'almost precise' value applies to the
corresponding toggle switch);
STUD_Term_Rat_TS, if the RDB option that involves CP termination for bolt length
calculations is active (in the WS software, the 'precise' value applies to the
corresponding toggle switch).
for the non-thru-bolted ends of the joint.
For machine bolts: the larger of the nut allowances derived from the applicable of the
tables described below:
STUD_Rat_TS, if the RDB option that involves CP termination for bolt length
calculations is not active (in the WS software, the 'almost precise' value applies to the
corresponding toggle switch).
STUD_Term_Rat_TS, if the RDB option that involves CP termination for bolt length
calculations is active (in the WS software, the 'precise' value applies to the
corresponding toggle switch).
for the non-thru-bolted ends of the joint, plus
For the termination types defined below, which represent "lap type" ends, the
schedule/thickness from the TDB of the RCP of each non-thru bolted end involved in the
flanged joint.
60 = FFLFTP [Flat-face lap-flanged termination type] (61-69)
70 = RFLFTP [Raised-face lap-flanged termination type] (71-79)
80 = RJFLFTP [RTJ-face lap-flanged termination type](81-89)
90 = TMFLFTP [Tongue/male-face lap-flanged termination type] (91-99)
100 = GFFLFTP [Groove/female-face lap-flanged termination type]
(101-109)
The resulting value will then be rounded up to the value indicated in table BOLT_LENGTH.
At the a bolted joint, regardless of the number of ends involved at the joint and of the design
volumes in which they might be found, the default ownership for all gaskets and studs required
by the joint is assigned by the system to the first non-thru-bolted end found by the system
during the stud selection process. This characteristic only affects the ownership of such
gaskets and studs. The stud selection itself is based on the criteria given in preceding
paragraphs and not on the properties of the first bolted end encountered by the system. If the
user has the need of assigning the ownership of gaskets and studs for the joint to a particular

Plant Design System (PDS) Piping Component Data

139

Commodity Discussions
bolted end, he may do so by setting the value of the applicable user-data attribute for the
applicable connect point to either "Default Gasket/Bolts/Nuts Ownership" or
"Gasket/Bolts/Nuts Owned by this Component". As was the case for the default ownership,
this attribute only controls in which isometric drawing the gaskets and studs are listed and not
their selection basis.

Fire and Safety Piping Components, On-line (6P4C),


In-line (6Q4C)
The applicability of the above AABB codes is as defined below for each component type.
The AABBCC code for fire and safety piping components consists of the applicable AABB code,
6P4C or 6Q4C, followed by two numbers for the specific type of component.
The Piping Component Model Entity and the Piping Component Analysis Entity will apply to these
classes of piping components.
Fire and safety piping components are included in the piping materials class of the line in which
placed. They are handled by the piping commodities part of the Piping Job Specification exactly
as they would be if they were a valve or a fitting.

See Also
Connect Point Data (on page 141)
6Q4C01, Fire monitor (in-line) (on page 145)
6Q4C02, Elevated fire monitor (in-line) (on page 145)
6Q4C03, Remotely operated fire monitor (in-line) (on page 145)
6Q4C04, Foam monitor (in-line) (on page 146)
6Q4C05 Elevated foam monitor (in-line) (on page 146)
6Q4C06, Remotely operated foam monitor (in-line) (on page 146)
6Q4C10, [2-way] fire hydrant (in-line) (on page 147)
6Q4C11, [2-way] fire hydrant w/monitor nozzle (in-line) (on page 147)
6Q4C13, 3-way fire hydrant (in-line) (on page 147)
6Q4C24, Hose reel (in-line) (on page 148)
6Q4C25, Hose rack station (in-line) (on page 148)
6Q4C26, Foam chamber (in-line) (on page 148)
6P4C30, Wet sprinkler (on-line) (on page 148)
6P4C31, Pre-action sprinkler (on-line) (on page 149)
6P4C32, Spray sprinkler (on-line) (on page 149)
6Q4C38, Eye wash (in-line) (on page 149)
6Q4C39, Safety shower (in-line) (on page 149)
6Q4C40, Safety shower and eye wash (in-line) (on page 149)
6Q4C60, [2-way] siamese (in-line) (on page 150)
6Q4C66, [2-way] 90 deg siamese (in-line) (on page 150)

140

Plant Design System (PDS) Piping Component Data

Commodity Discussions

Connect Point Data


For each component in the piping commodities part of the Piping Job Specification, component
specific data is defined in tables, as follows:

Green Connect Point Data Only, GCP=Male


If only green connect point data appears in the definition of the component in the piping
commodities part of the Piping Job Specification and if the connect point is a male termination
type, the following applies:
General data about the component is included in a table with format P11A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, weight of water plus all those
dimensional parameters required to display the component in the model whose values are not
defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P11B.
The name of the P11B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_B

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the component in the model that were not included in the P11A table.
The empty weight of the component is included in a table with format P51. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Sc/Th(G) WC
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the component.

Green Connect Point Data Only, GCP Male


If only green connect point data appears in the definition of the component in the piping
commodities part of the Piping Job Specification and if the connect point is not a male termination
type, the following applies:
General data about the component is included in a table with format P15A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) Rat(G) A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, weight of water plus all those
dimensional parameters required to display the component in the model whose values are not
defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P15B.
The name of the P15B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:

Plant Design System (PDS) Piping Component Data

141

Commodity Discussions
MC GS Term(G) Rat(G) B

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the component in the model that were not included in the P15A table.
The empty weight of the component is included in a table with format P52. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Sc/Th(G) WC
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The only dependent variable is empty weight of the component.

Green and Red Connect Point Data, GCP Male, RCP=Male


If both green and red connect point data appears in the definition of the component in the Piping
Job Specification, the green connect point is not a male termination type and the red connect point
is a male termination type, the following applies:
General data about the component is included in a table with format P25A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P25B.
The name of the P25B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) Term(R)_B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P25A
table.
The empty weight of the component is included in a table with format P61. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Sc/Th(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP Male, RCP Male
If both green and red connect point data appears in the definition of the component in the Piping
Job Specification and neither the green nor the red connect points are male termination types, the
following applies:
General data about the component is included in a table with format P26A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) A

142

Plant Design System (PDS) Piping Component Data

Commodity Discussions
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P26B.
The name of the P26B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P26A
table.
The empty weight of the component is included in a table with format P62. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Rat(G) Term(R) Rat(R) Sc/Th(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Green and Red Connect Point Data, GCP=Male, RCP=Male


If both green and red connect point data appears in the definition of the component in the Piping
Job Specification and both the green and the red connect points are male termination types, the
following applies:
General data about the component is included in a table with format P21A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC GS Term(G) Term(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P21B.
The name of the P21B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC GS Term(G) Term(R) B

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P21A
table.
The empty weight of the component is included in a table with format P63. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Sc/Th(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.

Plant Design System (PDS) Piping Component Data

143

Commodity Discussions
Green and Red Connect Point Data, GCP=Male, RCP Male
If both green and red connect point data appears in the definition of the component in the Piping
Job Specification, the green connect point is a male termination type and the red connect point is
not a male termination type, the following applies:
General data about the component is included in a table with format P27A. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Term(R) Rat(R) A
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P27B.
The name of the P27B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_GS_Term(G) Term(R) Rat(R) B

144

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are those dimensional
parameters required to display the component in the model that were not included in the P27A
table.
The empty weight of the component is included in a table with format P64. The name of this
table is comprised of the following parameters from the piping commodities part of the Piping
Job Specification:
MC_GS_Term(G) Sc/Th(G) Term(R) Rat(R) WC
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The only dependent variable is empty weight of the
component.
Fire and safety piping components are not placed during automatic component placement.
They must be positioned manually.
Under the description of each table format applicable to each component type, the GCP and
RCP rating and schedule/thickness that needs to be provided in the Piping Job Specification
has been listed. These values are required for one or more of the reasons indicated below and
will not necessarily be part of the names of the tables that include data about the component.
To procure the component.
To access data tables. Refer to section Model Graphics Definitions for a description of the
table formats.
To supply data required for stress analysis purposes.
The AABBCC code for fire and safety piping components consists of the applicable AABB
code, 6P4C or 6Q4C, followed by two numbers for the specific type of component.

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q4C01, Fire monitor (in-line)


Fire monitor type 1 (MC=MN1) (SN=FS1A)
TNF=P15A, P15B & P52
Flanged end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A, P11B & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C02, Elevated fire monitor (in-line)


Elevated fire monitor type 1 (MC=ME1) (SN=FS1A)
TNF=P15A, P15B & P52
Flanged end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A, P11B & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Elevated fire monitor type 2 (MC=ME2) (SN=FS2B)
TNF=P15A, P15B & P52
Flanged end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C03, Remotely operated fire monitor (in-line)


Remotely operated fire monitor type 1 (MC=MR1) (SN=FS1A)
TNF=P15A, P15B & P52
Flanged end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A, P11B & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

145

Commodity Discussions

6Q4C04, Foam monitor (in-line)


Foam monitor type 1 (MC=MF1) (SN=FS1A)
TNF=P15A, P15B & P52
Flanged end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A, P11B & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C05 Elevated foam monitor (in-line)


Elevated foam monitor type 1 (MC=MFE1) (SN=FS1A)
TNF=P15A, P15B & P52
Flanged end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A, P11B & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C06, Remotely operated foam monitor (in-line)


Remotely operated foam monitor type 1 (MC=MFR1) (SN=FS1A)
TNF=P15A, P15B & P52
Flanged end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P11A, P11B & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

146

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q4C10, [2-way] fire hydrant (in-line)


Fire hydrant type 1 (MC=H2W1) (SN=FS10A)
TNF=P15A, P15B & P52
Flanged end
Mechanical joint bell end
Push-on bell end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Fire hydrant type 2 (MC=H2W2) (SN=FS10B)
TNF=P15A & P52
Flanged end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C11, [2-way] fire hydrant w/monitor nozzle (in-line)


Fire hydrant w/monitor nozzle type 1 (MC=H2WN1) (SN=FS11A)
TNF=P26A, P26B & P62
Flanged/flanged ends
Flanged ends/mechanical joint bell
Flanged ends/push-on bell
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Fire hydrant w/monitor nozzle type 2 (MC=H2WN2) (SN=FS11B)
TNF=P26A, P26B & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q4C13, 3-way fire hydrant (in-line)


3-way fire hydrant type 1 (MC=H3W1) (SN=FS13A)
TNF=P15A, P15B & P52
Flanged end
Mechanical joint bell end
Push-on bell end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
3-way fire hydrant type 2 (MC=H3W2) (SN=FS13B)
TNF=P15A & P52
Flanged end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

147

Commodity Discussions

6Q4C24, Hose reel (in-line)


Hose reel type 1 (MC=HR1) (SN=FS24A)
TNF=P15A & P52
Socketwelded end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C25, Hose rack station (in-line)


Hose rack station type 1 (MC=HRST1) (SN=FS24A)
TNF=P15A & P52
Socketwelded end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C26, Foam chamber (in-line)


Foam chamber type 1 (MC=CF1) (SN=FS26A)
TNF=P26A & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Foam chamber type 2 (MC=CF2) (SN=FS26B)
TNF=P26A, P26B & P62
Flanged/flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6P4C30, Wet sprinkler (on-line)


Wet sprinkler type 1 (MC=SW1) (SN=FS30A)
TNF=P11A & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

148

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6P4C31, Pre-action sprinkler (on-line)


Pre-action sprinkler type 1 (MC=SPA1) (SN=FS30A)
TNF=P11A & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6P4C32, Spray sprinkler (on-line)


Spray sprinkler type 1 (MC=SSP1) (SN=FS30A)
TNF=P11A & P51
Male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C38, Eye wash (in-line)


Eye wash type 1 (MC=EW1) (SN=FS38A)
TNF=P26A, P26B & P62
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q4C39, Safety shower (in-line)


Safety shower type 1 (MC=SS1) (SN=FS39A)
TNF=P26A, P26B & P62
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q4C40, Safety shower and eye wash (in-line)


Safety shower and eye wash type 1 (MC=SSEW1) (SN=FS39A)
TNF=P26A, P26B & P62
Female threaded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
??
??
??
??
??

TNF=P15A & P52


Socketwelded end
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

??

o Taps must be placed during the design session as required


to define connections whose definition are not possible
with the EDEN definition.

Plant Design System (PDS) Piping Component Data

149

Commodity Discussions

6Q4C60, [2-way] siamese (in-line)


[2-way] siamese type 1 (MC=S2W1) (SN=FS60A)
TNF=P15A & P52
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q4C66, [2-way] 90 deg siamese (in-line)


[2-way] 90 deg siamese type 1 (MC=S2W901) (SN=FS66A)
TNF=P15A & P52
Female threaded end
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

In-Line Bio-Pharmaceutical Components (6Q5P)


Under the description of each table format applicable to each component type, the GCP and RCP
rating and schedule/thickness that needs to be provided in the Piping Job Specification has been
listed. These values are required for one or more of the reasons indicated below and will not
necessarily be part of the names of the tables that include data about the component.
To procure the component.
To access data tables.
To supply data required for stress analysis purposes.
The AABBCC code for fittings will consist of the applicable AABB code, 6Q5P, followed by the two
numbers for the specific type of fitting.

Bio-Pharmaceutical Specification Components


6Q5P01, Ferrule (in-line) (not-automatic)
Ferrule (MC=FERR) (ISK=LCXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

150

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q5P02, Short ferrule (in-line) (not-automatic)


Short ferrule (MC=FERS) (ISK=LCXX)
TNF=MS_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P03, Extended tangent cap (in-line) (not-automatic)


Extended tangent cap (MC=CAPT) (ISK=KAXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P04, Solid end cap (in-line) (not-automatic)


Solid end cap (MC=CAPSE) (ISK=KAXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q5P05, Hose adapter (in-line) (not-automatic)


Hose adapter (MC=HA) (ISK=CHXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Male clamp end/male hose end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P06, Female adapter (in-line) (not-automatic)


Female adapter (MC=FA) (ISK=ADMF)
TNF=MC_GS_TERM(G)_TERM(R)_RAT(R)_A
MC_GS_TERM(G)_TERM(R)_RAT(R)_WC
Male clamp end/female threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"

Plant Design System (PDS) Piping Component Data

151

Commodity Discussions

6Q5P07, Reducing female adapter (in-line) (not-automatic)


Reducing female adapter (MC=FAR) (ISK=ADMF)
TNF=MC_GS_TERM(G)_TERM(R)_RAT_(R)_A
MC_GS_TERM(G)_TERM(R)_RAT(R)_WC
Male clamp end/female threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"

6Q5P08, Male adapter (in-line) (not-automatic)


Male adapter (MC=MA) (ISK=ADMM)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Male clamp end/male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P09, Reducing male adapter (in-line) (not-automatic)


Reducing male adapter (MC=MAR) (ISK=ADMM)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Male clamp end/male threaded end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P10, 90 deg tube bend (in-line) (not-automatic)


90 deg tube bend (MC=B90T) (ISK=ELXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

152

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q5P11, 90 deg tube bend (in-line) (not-automatic)


90 deg tube bend (MC=B90TC) (ISK=ELXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P12, 90 deg elbow (in-line) (not-automatic)


90 deg elbow (MC=B90C) (ISK=ELXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P13, 45 deg tube bend (in-line) (not-automatic)


45 deg tube bend (MC=B45T) (ISK=ELXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P14, 45 deg tube bend (in-line) (not-automatic)


45 deg tube bend (MC=B45TC) (ISK=ELXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P15, 45 deg elbow (in-line) (not-automatic)


45 deg elbow (MC=B45C) (ISK=ELXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

153

Commodity Discussions

6Q5P16, 180 deg return bend (in-line) (not-automatic)


180 deg return bend (MC=R180R) (ISK=EUPL)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P19, 180 deg return bend (in-line) (not-automatic)


180 deg return bend (MC=R180C) (ISK=BUFL)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P21, Tee (in-line) (not-automatic)


Tee (MC=TT) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P22, Reducing tee (in-line) (not-automatic)


Reducing tee (MC=TTRB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_TERM(R)_A
MC_GS_TERM(G)_SC/TH(G)_TERM(R)_SC/TH(R)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P23, Tee (in-line) (not-automatic)


Tee (MC=TCB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

154

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q5P24, Reducing tee (in-line) (not-automatic)


Reducing tee (MC=TRCB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P25, Short outlet tee (in-line) (not-automatic)


Short outlet tee (MC=TSCB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P26, Short outlet reducing tee (in-line) (not-automatic)


Short outlet reducing tee (MC=TRSCB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P27, Instrument tee (in-line) (not-automatic)


Instrument tee (MC=TICB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P28, Short outlet run tee (in-line) (not-automatic)


Short outlet run tee (MC=TSCR) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end/plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

Plant Design System (PDS) Piping Component Data

155

Commodity Discussions

6Q5P31, Cross (in-line) (not-automatic)


Cross (MC=XT) (ISK=CRXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P32, Reducing cross (in-line) (not-automatic)


Reducing cross (MC=XTRB) (ISK=CRXX)
TNF=MC_GS_TERM(G)_TERM(R)_A
MC_GS_TERM(G)_SC/TH(G)_TERM(R)_SC/TH(R)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P33, Cross (in-line) (not-automatic)


Cross (MC=XC) (ISK=CRXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P35, Tee (in-line) (not-automatic)


Tee (MC=TC) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P36, Reducing tee (in-line) (not-automatic)


Reducing tee (MC=TCR) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

156

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q5P37, Short outlet tee (in-line) (not-automatic)


Short outlet tee (MC=TCSB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P38, Short outlet reducing tee (in-line) (not-automatic)


Short outlet reducing tee (MC=TCRSB) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P39, Instrument tee (in-line) (not-automatic)


Instrument tee (MC=TCI) (ISK=TEXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P41, Concentric reducer (in-line) (not-automatic)


Concentric reducer (MC=RCP) (ISK=RCXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_TERM(R)_SC/TH(R)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P42, Concentric reducer (in-line) (not-automatic)


Concentric reducer (MC=RCCL) (ISK=RCXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_TERM(R)_SC/TH(R)_WC
Male clamp end/plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

Plant Design System (PDS) Piping Component Data

157

Commodity Discussions

6Q5P43, Concentric reducer (in-line) (not-automatic)


Concentric reducer (MC=RCC) (ISK=RCXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P45, Eccentric reducer (in-line) (not-automatic)


Eccentric reducer (MC=REP) (ISK=REXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_TERM(R)_SC/TH(R)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P46, Eccentric reducer (in-line) (not-automatic)


Eccentric reducer (MC=RECL) (ISK=REXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_TERM(R)_SC/TH(R)_WC
Male clamp end/plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="Value"

6Q5P47, Eccentric reducer (in-line) (not-automatic)


Eccentric reducer (MC=REC) (ISK=REXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P51, Clamp, adjustable (in-line) (not-automatic)


Clamp, adjustable (MC=CHA) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

158

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q5P52, Clamp, heavy duty (in-line) (not-automatic)


Clamp, heavy duty (MC=C2HD) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q5P53, Clamp, 3 piece heavy duty (in-line) (not-automatic)


Clamp, 3 piece heavy duty (MC=C3HD) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q5P54, Clamp, pressure adjustable (in-line) (not-automatic)


Clamp, pressure adjustable (MC=CPAN) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q5P55, Clamp, high pressure (in-line) (not-automatic)


Clamp, high pressure (MC=CHPB) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q5P56, Clamp, assembly (in-line) (not-automatic)


Clamp, assembly (MC=CA) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

159

Commodity Discussions

6Q5P57, Clamp, swivel joint (in-line) (not-automatic)


Clamp, swivel joint (MC=CSJ) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q5P58, Clamp, 2 piece heavy duty (in-line) (not-automatic)


Clamp, 2 piece heavy duty (MC=CHD) (ISK=CLMP)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Female clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

6Q5P60, 2-way diaphragm valve (in-line) (not-automatic)


2-way diaphragm valve (MC=VS2D) (ISK=VDXX)
TNF=MC_GS_TERM(G)_A
COMMODITY_CODE
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P61, 2-way diaphragm valve (in-line) (not-automatic)


2-way diaphragm valve (MC=VS2D) (ISK=VDXX)
TNF=MC_GS_TERM(G)_A
COMMODITY_CODE
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

Bio-Pharmaceutical Operators
SOP3, Manual bonnet (in-line) (not-automatic)
Manual bonnet (MC=SOP_3) (ISK=N/A)
TNF='MB'_GS_OP_A

160

Plant Design System (PDS) Piping Component Data

Commodity Discussions

SOP42, Pneumatic bonnet (in-line) (not-automatic)


Pneumatic bonnet (MC=SOP_42) (ISK=N/A)
TNF='EC'_GS_OP_A
'EC'_GS_OP_WC

Bio-Pharmaceutical Specialty Components


6Q5P17, Use point 180 deg return (in-line) (not-automatic)
Use point 180 deg return (MC=R180B) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P18, Use point 180 deg return (in-line) (not-automatic)


Use point 180 deg return (MC=R180S) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_SC/TH(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P62, Zero deadleg T valve (in-line) (not-automatic)


Zero deadleg T valve (MC=VSDTP) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P63, Zero deadleg T valve (in-line) (not-automatic)


Zero deadleg T valve (MC=VSDTC) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_52
Male clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Plant Design System (PDS) Piping Component Data

161

Commodity Discussions

6Q5P65, Close-coupled branch valve (in-line) (not-automatic)


Close-coupled branch valve (MC=VSCCB) (ISY=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P66, Close-coupled branch valve (in-line) (not-automatic)


Close-coupled branch valve (MC=VSCCB) (ISY=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Plain end/male clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="NREQD"

6Q5P68, Use point close-coupled branch valve (in-line)


(not-automatic)
Use point close-coupled branch valve (MC=VSCCBU) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P69, Use point close-coupled branch valve (in-line)


(not-automatic)
Use point close-coupled branch valve (MC=VSCCBU) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="NREQD"

162

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q5P75, 3 way diverter valve (in-line) (not-automatic)


3 way diverter valve (MC=VS3WD) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P76, 3 way diverter valve (in-line) (not-automatic)


3 way diverter valve (MC=VS3WD) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P77, 4 way diverter valve (in-line) (not-automatic)


4 way diverter valve (MC=VS4WD) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Plain end
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"

6Q5P78, 4 way diverter valve (in-line) (not-automatic)


4 way diverter valve (MC=VS4WD) (ISK=XVXX)
TNF=MC_GS_TERM(G)_A
MC_GS_TERM(G)_WC
Male clamp end
For GCP: Rating="-"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"

Piping Specialty Components, On-line (6P6C) , In-line


(6Q6C)
The applicability of the above AABB codes is as defined below for each component type.
The AABBCC code for piping specialty components consists of the applicable AABB code, 6P6C
or 6Q6C, followed by two numbers for the specific component type.
The Piping Component Model Entity and the Piping Component Analysis Entity will apply to these
classes of piping components.
Piping specialty components are not included in the piping materials class of the line in which
placed. They are independent of piping materials class.

Plant Design System (PDS) Piping Component Data

163

Commodity Discussions
See Also
Named and Unamed Specialties (on page 165)
Connect Point Data (on page 165)
6Q6C01, Flame arrestor (in-line) (PID piping comp type 513) (on page 168)
6Q6C03, Hammer arrestor (in-line) (PID piping comp type 515) (on page 168)
6Q6C04, Vent silencer (in-line) (PID piping comp type 516) (on page 168)
6Q6C05, In-line silencer (in-line) (PID piping comp type 517) (on page 168)
6Q6C07, Exhaust head (in-line) (PID piping comp type 519) (on page 169)
6Q6C09, Breather vent (in-line) (PID piping comp type 521) (on page 169)
6Q6C11, Free vent w/o screen (in-line) (PID piping comp type 523) (on page 169)
6Q6C12, Free vent w/screen (in-line) (PID piping comp type 524) (on page 169)
6Q6C13, Motor operated valve (in-line) (with operator) (on page 169)
6Q6C15, Mixing T (in-line) (PID piping comp type 527) (on page 169)
6P6C17, Spray nozzle (on-line) (PID piping comp type 529) (on page 169)
6Q6C21, Removable spool (in-line) (PID piping comp type 533) (on page 170)
6Q6C23, Swing elbow (in-line) (PID piping comp type 535) (on page 170)
6Q6C28, Expansion joint (in-line) (PID piping comp type 540) (on page 170)
6Q6C30, Hinged expansion joint (in-line) (PID piping comp type 542) (on page 170)
6Q6C32, Swivel joint (in-line) (PID piping comp type 544) (on page 170)
6Q6C34, Mechanical coupling (in-line) (PID piping comp type 546) (on page 171)
6Q6C36, Flexible hose (in-line) (PID piping comp type 548) (on page 171)
6Q6C40, Sample cooler (in-line) (PID piping comp type 552) (on page 172)
6Q6C45, Single basket strainer (in-line) (PID piping comp type 557) (on page 172)
6Q6C47, Duplex basket strainer (in-line with operator) (PID piping comp type 559) (on page
172)
6Q6C49, T strainer (in-line) (PID piping comp type 561) (on page 172)
6Q6C51, Y strainer (in-line) (PID piping comp type 563) (on page 173)
6Q6C52, Temporary strainer (in-line) (PID piping comp type 564) (on page 173)
6Q6C53, Basket strainer (in-line) (PID piping comp type 565) (on page 173)
6Q6C55, Cone strainer (in-line) (PID piping comp type 567) (on page 174)
6Q6C57, Flat plate strainer (in-line) (PID piping comp type 569) (on page 174)
6Q6C59, Sump strainer (in-line) (PID piping comp type 571) (on page 174)
6Q6C64, Filter (in-line) (PID piping comp type 576) (on page 174)
6Q6C70, Steam trap (in-line) (PID piping comp type 582) (on page 174)
6Q6C71, Float steam trap (in-line) (PID piping comp type 583) (on page 174)
6Q6C72, Inverted bucket steam trap (in-line) (PID piping comp type 584) (on page 174)
6Q6C74, Thermostatic steam trap (in-line) (PID piping comp type 586) (on page 174)
6Q6C76, Thermodynamic steam trap (in-line) (PID piping comp type 588) (on page 174)
6Q6C78, Impulse steam trap (in-line) (PID piping comp type 590) (on page 174)
6Q6C99, Generic component (in-line) (PID piping comp type 611) (on page 175)

164

Plant Design System (PDS) Piping Component Data

Commodity Discussions

Named and Unamed Specialties


Piping specialty components can be either named or unnamed, as follows:
Named components are those components to which a project unique name, called component
number, is assigned by the User in the Piping TDB AND whose dimensional data has been
defined in the applicable unit of the Instrument Task. The storage of data about piping
specialty components in the Instrument Task is temporary and only until such time as the
Piping Specialties Task is developed.
Unnamed components are those components to which either a component number is not
assigned by the User in the Piping TDB and/or whose dimensional data has not been defined
in the applicable unit of the Instrument Task. During the design process, it is possible for a
piping specialty component to first be considered unnamed and then named, and vice versa.
Data about unnamed piping specialty components is stored in the piping specialties part of the
Piping Job Specification. The primary access key to named piping specialty components is
their AABBCC code. An AABBCC code may be considered as a generic code about which a
more detailed definition is made in the Piping Job Specification. Depending upon the
circumstances:
One or more model codes may be assigned to one AABBCC code, or
The same model code may be assigned to different AABBCC codes.
The system will first search for dimensional data about the piping specialty component in the
Instrument TDB. In this search, the system will try to match the component number of the piping
specialty component with the "tag number" assigned to it in the Instrument TDB. If dimensional
data about the component is found, the system will assume the component to be named and will
proceed to retrieve dimensional data about it.
If either the component or dimensional data about it is not found, the system will conclude that the
component is unnamed and will then search for it in the piping specialties part of the Piping Job
Specification by its AABBCC code, option and pertinent size range and will proceed to retrieve
applicable data about it.
One of the items retrieved from either the Instrument TDB or the Piping Job Specification is the
model code, which will include the definition of the graphic representation of the component in the
piping model.

Connect Point Data


Connect point dependent data about each component is organized in terms of green and red
connect points. So that the various sets of data that may exist about these connect points can
remain coordinated, the following conventions have been followed regarding the sequence of data
in the Instrument TDB and in the Piping Job Specification and regarding the naming of the
Interactive Data Tables:
If data is only shown under green connect point data, it applies to all ends of the component.
If the component has ends of two different nominal diameters, regardless of how the other end
properties compare, properties about the larger nominal diameter end(s) have been defined
under the green connect point data.
If the component has ends of the same nominal diameter but differing in some of the other end
properties, the following applies:
If the termination type of the ends differ, regardless of the values for schedule/thickness,
the properties of the end(s) with the lowest codelist number defining its CP preparation
have been defined under the green connect point data.

Plant Design System (PDS) Piping Component Data

165

Commodity Discussions

If the termination type of the ends are the same but the values for rating, schedule or
thickness differ, the properties of the "stronger" ends(s) have been defined under the
green connect point data.
For each piping specialty component, dimensional data is defined in tables, as follows:
Named Specialty - If the component is named, regardless of its other characteristics, the
following applies:
Both generic and specific data about the component is included in the applicable unit of
the Instrument TDB.
Refer to the explanation given under table format P80 for details.
Unnamed Specialty, GCP = male - If the component is unnamed, if only green connect point
data appears in the definition of the component in the piping specialties part of the Piping Job
Specification and if the connect point is a male termination type, the following applies:
Data about the component is included in a table with format P81. The name of this table is
comprised of the following parameters from the piping specialties part of the Piping Job
Specification:
MC GS Term(G) Unnamed_P
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water,
weight of the operator plus all those dimensional parameters required to display the
component and its operator, if any, in the model whose values are not defined in a generic
table.

Unnamed Specialty, GCP male - If the component is unnamed, if only green connect point
data appears in the definition of the component in the piping specialties part of the Piping Job
Specification and if the connect point is not a male termination type, the following applies:
Data about the component is included in a table with format P85. The name of this table is
comprised of the following parameters from the piping specialties part of the Piping Job
Specification:
MC GS Term(G) Rat(G) Unnamed_P
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water,
weight of the operator plus all those dimensional parameters required to display the
component and its operator, if any, in the model whose values are not defined in a generic
table.
Unnamed Specialty, GCP=bolted or female, RCP=male - If the component is unnamed, if
both green and red connect point data appears in the definition of the component in the piping
specialties part of the Piping Job Specification, the "green" connect point is either a bolted or a
female termination type and the red connect point is a male termination type, the following
applies:
Data about the component is included in a table with format P95. The name of this table is
comprised of the following parameters from the piping specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Unnamed_P
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the operator plus all those dimensional parameters required to
display the component and its operator, if any, in the model whose values are not defined in a
generic table.

166

Unnamed Specialty, GCP male, RCP male - If the component is unnamed, if both green
and red connect point data appears in the definition of the component in the piping specialties

Plant Design System (PDS) Piping Component Data

Commodity Discussions
part of the Piping Job Specification and neither the green nor the red connect points are male
termination types, the following applies:
Data about the component is included in a table with format P96. The name of this table is
comprised of the following parameters from the piping specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) Unnamed_P

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the operator plus all those dimensional parameters required to
display the component and its operator, if any, in the model whose values are not defined in a
generic table.
Unnamed Specialty, GCP=male, RCP=male - If the component is unnamed, if both green
and red connect point data appears in the definition of the component in the piping specialties
part of the Piping Job Specification and both the green and the red connect points are male
termination types, the following applies:
Data about the component is included in a table with format P91. The name of this table is
comprised of the following parameters from the piping specialties part of the Piping Job
Specification:
MC GS Term(G) Term(R) Unnamed_P
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the operator plus all those dimensional parameters required to
display the component and its operator, if any, in the model whose values are not defined in a
generic table.

Unnamed Specialty, GCP=male, RCP male - If the component is unnamed, if both green
and red connect point data appears in the definition of the component in the piping specialties
part of the Piping Job Specification, the "green" connect point is a male termination type and
the red connect point is not a male termination type, the following applies:
Data about the component is included in a table with format P97. The name of this table is
comprised of the following parameters from the piping specialties part of the Piping Job
Specification:
MC_GS_Term(G) Term(R) Rat(R) Unnamed_P
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the operator plus all those dimensional parameters required to
display the component and its operator, if any, in the model whose values are not defined in a
generic table.
Piping specialty components will not have operators unless otherwise specifically indicated in
paragraphs that follow. Operators, if applicable, will always be defined independent of the
components. Refer to paragraph C6.1 for additional requirements regarding operators.
Piping specialty components and their operators are not placed during automatic component
placement. They must be positioned manually.
Reference to "ends" in component type definitions that follow refer to the applicable of in-line
or tap ends that might apply to the component.
Under the description of each table format applicable to each component type, the GCP and
RCP rating and schedule/thickness that needs to be provided in the Piping Job Specification
has been listed. These values are required for one or more of the reasons indicated below and
will not necessarily be part of the names of the tables that include data about the component.
To procure the component.

Plant Design System (PDS) Piping Component Data

167

Commodity Discussions

To access data tables. Refer to Section 4, Model Graphics Definitions, for a description of
the table formats.
To supply data required for stress analysis purposes.
The following general comments apply to the use of symbols used to depict these piping specialty
components:
The symbols shown below under each piping specialty component type are only suggested
symbols that can be used to depict such piping specialty components. Any piping specialty
component symbol defined in Paragraph C.3.1 may be used instead.
Insure that for each symbol used, a proper match has been to an Isogen symbol.
Unless specifically defined otherwise, symbols listed below have been defined so that they
can be placed either with or without actuators.
Taps may be placed during the design session as required to define connections whose
definition is not possible with the symbol chosen.
The AABBCC code for piping specialty components consists of the applicable AABB code, 6P6C
or 6Q6C, followed by two numbers for the specific component type.

6Q6C01, Flame arrestor (in-line) (PID piping comp type 513)


Flame arrestor type 1 (MC=S1AT or S1AS) (SN=S1AZ)
Flame arrestor type 2 (no actuator) (MC=S1BT or S1BS)
(SN=S1BZ)

6Q6C03, Hammer arrestor (in-line) (PID piping comp type


515)
Hammer arrestor type 1 (MC=S3AT or S3AS) (SN=S3AZ)

6Q6C04, Vent silencer (in-line) (PID piping comp type 516)


Vent silencer type 1 (MC=S4AT or S4AS) (SN=S4AZ)

6Q6C05, In-line silencer (in-line) (PID piping comp type 517)


In-line silencer type 1 (MC=S5AT or S5AS) (SN=S5AZ)
In-line silencer type 2 (MC=S4AT or S4AS) (SN=S4AZ)

168

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q6C07, Exhaust head (in-line) (PID piping comp type 519)


Exhaust head type 1 (no actuator) (MC=S7AT or S7AS)
(SN=S7AZ)

6Q6C09, Breather vent (in-line) (PID piping comp type 521)


6Q6C11, Free vent w/o screen (in-line) (PID piping comp
type 523)
Free vent w/o screen type 1 (no actuator) (MC=S1BT or S1BS)
(SN=S1BZ)
Free vent w/o screen type 2 (MC=S11BT or S11BS) (SN=S11BZ)

6Q6C12, Free vent w/screen (in-line) (PID piping comp type


524)
Free vent w/screen type 1 (no actuator) (MC=S1BT or S1BS)
(SN=S1BZ)
Free vent w/screen type 2 (MC=S11BT or S11BS) (SN=S11BZ)

6Q6C13, Motor operated valve (in-line) (with operator)


(P&ID piping comp type=525)
Motor operated valve type 1 (MC=S13AT or S13AS) (SN=S13AZ)

6Q6C15, Mixing T (in-line) (PID piping comp type 527)


This component will only apply to the P&ID Task. It is
built up from fittings in the Piping Task. It is
acceptable for a comparison between designs in the P&ID and
Piping Tasks to report an inconsistency because of this
item.

6P6C17, Spray nozzle (on-line) (PID piping comp type 529)


Spray nozzle type 1 (no actuator) (MC=S1BT or S1BS)
(SN=S1BZ)

Plant Design System (PDS) Piping Component Data

169

Commodity Discussions

6Q6C21, Removable spool (in-line) (PID piping comp type


533)
This component will only apply to the P&ID Task. It is
built up from fittings in the Piping Task. It is
acceptable for a comparison between designs in the P&ID and
Piping Tasks to report an inconsistency because of this
item.

6Q6C23, Swing elbow (in-line) (PID piping comp type 535)


This component will only apply to the P&ID Task. It is
built up from fittings in the Piping Task. It is
acceptable for a comparison between designs in the P&ID and
Piping Tasks to report an inconsistency because of this
item.

6Q6C28, Expansion joint (in-line) (PID piping comp type


540)
Expansion joint type 1, w/o offset (no actuator) (MC=S28AT
or S28AS) (SN=S28AZ)
Expansion joint type 2, w/offset (no actuator) (MC=S28BT or
S28BS) (SN=S28BZ)

6Q6C30, Hinged expansion joint (in-line) (PID piping comp


type 542)
Hinged expansion joint type 1, w/o offset (no actuator)
(MC=S28AT or S28AS) (SN=S28AZ)
Hinged expansion joint type 2, w/offset (no actuator)
(MC=S28BT or S28BS) (SN=S28BZ)

6Q6C32, Swivel joint (in-line) (PID piping comp type 544)


Swivel joint type 1, straight thru (MC=S4AT or S4AS)
(SN=S4AZ)
Swivel joint type 2, single elbow (MC=S32BT or S32BS)
(SN=S32BZ)
Swivel joint type 3, double elbow (MC=S3AT or S3AS)
(SN=S3AZ)

170

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q6C34, Mechanical coupling (in-line) (PID piping comp


type 546)
Dresser coupling type 1 (MC=S5AT or S5AS) (SN=S5AZ)

6Q6C36, Flexible hose (in-line) (PID piping comp type 548)


Flexible hose type 1 (no actuator) (MC=S36AT or S36AS)
(SN=S36AZ)
The requirements for flexible hoses are as follows:
o As with other specialty components, selection of a
flexible hose may be made either by:
- Defining its component number, or
- Defining it generically. In this case, the User at the
terminal will first select the "Option" code that
defines the end preparation that he wishes to use at the
ends of the hose. He will then select the AABBCC code
that applies to these components.
o With the above information, the system will establish from
the piping specialties section of the Piping Job
Specification the type of end preparation to be used at
the ends of the hose.
o The system will prompt the User to define the location of
the two connect points that define the ends of the hose.
o The system will prompt the User to define points in space
that define the route of the centerline of the hose.
o With this information, the system will display the
graphics that represent the ends of the flexible hose.
The centerline of these graphics will then be joined by
the system with the points that define the centerline of
the hose. A solid, heavy weight, single line is used
to represent this centerline.
o The system will display to the User the linear length of
the line representing the centerline of the hose and will
prompt the User to define the length of the hose to be
provided. This length is stored in the TDB and will
be available in the procurement of the component.
o There is no table that defines data which is specific
to flexible hoses.

Plant Design System (PDS) Piping Component Data

171

Commodity Discussions

6Q6C40, Sample cooler (in-line) (PID piping comp type 552)


Sample cooler type 1 (MC=S4AT or S4AS) (SN=S4AZ)
Sample cooler type 2 (MC=S32BT or S32BS) (SN=S32BZ)

6Q6C45, Single basket strainer (in-line) (PID piping comp


type 557)
Single basket strainer type 1 (MC=S3AT or S3AS) (SN=S3AZ)

6Q6C47, Duplex basket strainer (in-line with operator)


(PID piping comp type 559)
Duplex basket strainer type 1 (MC=S1AT or S1AS) (SN=S1AZ)

6Q6C49, T strainer (in-line) (PID piping comp type 561)


T strainer, commodity type 1 (MC=S49AC) (SN=S49AC)
TNF=P15A & P59
Flanged ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
TNF=P26A & P62
Flanged/socketwelded ends
Flanged/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="Value"
TNF=P15A & P59
Beveled ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="-"; Sc/Th="-"
TNF=P27A & P59
Beveled/flanged ends
Beveled/socketwelded ends
Beveled/female threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"
T strainer, specialty type 1 (no actuator) (MC=S49AT or
S49AS) (SN=S49AZ)

172

Plant Design System (PDS) Piping Component Data

Commodity Discussions

6Q6C51, Y strainer (in-line) (PID piping comp type 563)


Y strainer, commodity type 1 (no actuator) (MC=S51AC)
(SN=S51AC)
TNF=P27A & P59
Beveled/socketwelded ends
Beveled/female threaded ends
For GCP: Rating="-"; Sc/Th="Value"
For RCP: Rating="Value"; Sc/Th="NREQD"
TNF=P26A & P59
Socketwelded/socketwelded ends
Socketwelded/female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="Value"; Sc/Th="NREQD"
Y strainer, specialty type 1 (no actuator) (MC=S51AT or
S51AS) (SN=S51AZ)

6Q6C52, Temporary strainer (in-line) (PID piping comp type


564)
Any of the model codes for strainers may be used under this
AABBCC code.

6Q6C53, Basket strainer (in-line) (PID piping comp type 565)


Basket strainer, commodity type 1 (no actuator) (MC=S53AC)
(SN=S53AC)
TNF=P15A & P59
Thru-bolted ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Basket strainer, specialty type 1 (no actuator) (MC=S53AT or
S53AS) (SN=S53AZ)

Plant Design System (PDS) Piping Component Data

173

Commodity Discussions

6Q6C55, Cone strainer (in-line) (PID piping comp type 567)


Cone strainer type 1 (no actuator) (MC=S53AT or S53AS)
(SN=S53AZ)

6Q6C57, Flat plate strainer (in-line) (PID piping comp type


569)
Flat plate strainer type 1 (no actuator) (MC=S53AT or S53AS)
(SN=S53AZ)

6Q6C59, Sump strainer (in-line) (PID piping comp type 571)


Sump strainer type 1 (no actuator) (MC=S1BT or S1BS)
(SN=S1BZ)

6Q6C64, Filter (in-line) (PID piping comp type 576)


Filter type 1 (MC=S3AT or S3AS) (SN=S3AZ)
Filter type 2 (MC=S64BT or S64BS) (SN=S64BZ)

6Q6C70, Steam trap (in-line) (PID piping comp type 582)


6Q6C71, Float steam trap (in-line) (PID piping comp type
583)
6Q6C72, Inverted bucket steam trap (in-line) (PID piping
comp type 584)
6Q6C74, Thermostatic steam trap (in-line) (PID piping comp
type 586)
6Q6C76, Thermodynamic steam trap (in-line) (PID piping
comp type 588)
6Q6C78, Impulse steam trap (in-line) (PID piping comp type
590)
For types 70 through 78 use any of the symbols defined
below:
Steam trap, commodity type 1, (MC=S1AC) (SN=S1AC)
Steam trap, commodity type 2, (MC=S3AC) (SN=S3AC)
Steam trap, commodity type 3, (MC=S4AC) (SN=S4AC)

174

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Steam trap, commodity type 4, (MC=S32BC) (SN=S32BC)
Steam trap, commodity type 5, (MC=S64BC) (SN=S64BC)
Steam trap, commodity type 6, (MC=S70AC) (SN=S70AC)
Steam trap, commodity type 7, (MC=S70BC) (SN=S70BC)
Steam trap, commodity type 8 (no actuator), (MC=S78AC)
(SN=S78AC)
TNF=P15A & P59
Socketwelded ends
Female threaded ends
For GCP: Rating="Value"; Sc/Th="NREQD"
For RCP: Rating="-"; Sc/Th="-"
Steam trap, specialty type 1, (MC=S1AT or S1AS) (SN=S1AZ)
Steam trap, specialty type 2, (MC=S3AT or S3AS) (SN=S3AZ)
Steam trap, specialty type 3, (MC=S4AT or S4AS) (SN=S4AZ)
Steam trap, specialty type 4, (MC=S32BT or S32BS) (SN=S32BZ)
Steam trap, specialty type 5, (MC=S64BT or S64BS) (SN=S64BZ)
Steam trap, specialty type 6 (no actuator), (MC=S78AT or
S78AS) (SN=S78AZ)

6Q6C99, Generic component (in-line) (PID piping comp type


611)
Any of the model codes for in-line piping specialty
components may be used under this AABBCC code.

Instrument Specialty Discussions


See Also
Signal Lines (7N2A) (on page 176)
Control Valves and Regulators (7P1E) (on page 176)
Relief Devices (7P2C) (on page 186)
Other in-line Instruments (7P3C) (on page 191)
Off-Line Instruments (7Q4D) (on page 201)

Plant Design System (PDS) Piping Component Data

175

Commodity Discussions

Signal Lines (7N2A)


There is no data in the alphanumeric database of the Piping Task to represent this class of
instrument components.
It is possible to connect signal lines to PCPs, pipelines or other signal lines. The system will
refuse to allow the connection of signal lines to other items.
AABBCC
Description
7N2A01, Conn to process/supply line
7N2A02, Capillary tube
7N2A03, Mechanical link

Control Valves and Regulators (7P1E)


The AABBCC code for control valves and regulators will consist of the applicable AABB code,
7P1E, followed by two numbers for the specific instrument.
The Instrument Component Model Entity and the Instrument Component Analysis Entity will apply
to this class of instrument components.
Control valves and regulators may be:
Connected to an equipment nozzle by direct mounting on it.
Connected to a pipeline by either:
Insertion in it
Direct mounting to the PCP of an in-line piping component
Direct mounting to the PCP of another in-line instrument component.
Placed unconnected.
It is possible either to insert these instrument components in the pipeline in which they belong with
the system breaking the line graphics as required (the system will rotate the instrument
component as dictated by the orientation of the line in which it is to be inserted); or to place these
components in free space and then pipe to them.
Control valves and regulators will not be included in the piping materials class of the line in which
placed. They are independent of piping materials class.

See Also
Named and Unnamed Instruments (on page 177)
Connect Point Data (on page 178)
7P1E01, [2-way generic body] control valve (in-line) (on page 181)
7P1E02, [2-way generic body] angle control valve (in-line) (on page 181)
7P1E03, 3-way [generic body] control valve (in-line) (on page 181)
7P1E04, 4-way [generic body] control valve (in-line) (on page 181)
7P1E05, [2-way] angle globe control valve (in-line) (on page 181)
7P1E06, 3-way globe control valve (in-line) (on page 181)
7P1E07, [2-way] solenoid valve (in-line) (on page 181)
7P1E08, [2-way] angle solenoid valve (in-line) (on page 182)
7P1E09, 3-way solenoid valve (in-line) (on page 182)
7P1E10, 4-way solenoid valve (in-line) (on page 182)
7P1E11, 3-way plug control valve (in-line) (on page 182)
7P1E12, 4-way plug control valve (in-line) (on page 182)
7P1E13, [2-way] ball control valve (in-line) (on page 182)

176

Plant Design System (PDS) Piping Component Data

Commodity Discussions
7P1E14, 3-way ball control valve (in-line) (on page 182)
7P1E15, [2-way] globe control valve (in-line) (on page 183)
7P1E16, [2-way] plug control valve (in-line) (on page 183)
7P1E17, [2-way] butterfly control valve (in-line) (on page 183)
7P1E18, [2-way] knife gate control valve (in-line) (on page 183)
7P1E19, [2-way] diaphragm control valve (in-line) (on page 183)
7P1E20, [2-way] slide control valve (in-line) (on page 183)
7P1E21, 3-way slide control valve (in-line) (on page 183)
7P1E22, [2-way] multivane 1 damp/louv CV (in-line) (on page 184)
7P1E23, [2-way] multivane 2 damp/louv CV (in-line) (on page 184)
7P1E24, [2-way] single vane damp/louv CV (in-line) (on page 184)
7P1E27, Control valve w/equip (in-line) (on page 184)
7P1E30, Automatic recirculation valve (in-line) (on page 184)
7P1E33, Self contained press red reg (in-line) (on page 184)
7P1E34, Press red reg w/ ext tap (in-line) (on page 185)
7P1E35, Press red reg w/ int RV (in-line) (on page 185)
7P1E38, Self contained backpress reg (in-line) (on page 185)
7P1E39, Backpress reg w/ ext tap (in-line) (on page 185)
7P1E42, Diff press red reg w/int & ext taps (in-line) (on page 185)
7P1E44, [2-way] filled system temp reg (in-line) (on page 185)
7P1E45, [2-way] angle filled system temp reg (in-line) (on page 185)
7P1E46, 3-way filled system temp reg (in-line) (on page 186)

Named and Unnamed Instruments


Control valves and regulators can be either named or unnamed, as follows:
Named components are those components to which a project unique name, called component
number, is assigned by the User in the Piping TDB AND whose dimensional data has been
defined in the applicable unit of the Instrument Task.
Unnamed components are those components to which either a component number has not
been assigned by the User in the Piping TDB and/or whose dimensional data has not been
defined in the applicable unit of the Instrument Task. During the design process, it is possible
for a control valve or regulator to first be considered unnamed and then named, and vice
versa. Data about unnamed control valves and regulators is stored in the instrument
specialties part of the Piping Job Specification. The primary access key to named control
valves and regulators is their AABBCC code. An AABBCC code may be considered as a
generic code about which a more detailed definition is made in the Piping Job Specification.
Depending upon the circumstances:
One or more model codes may be assigned to one AABBCC code, or
The same model code may be assigned to different AABBCC codes.
The system will first search for dimensional data about the control valve or regulator in the
Instrument TDB. In this search, the system will try to match the component number of the control
valve or regulator with the tag number assigned to it in the Instrument TDB. If dimensional data
about the component is found, the system will assume the component to be named and will
proceed to retrieve dimensional data about it.
If either the component or dimensional data about it is not found, the system will conclude that the
component is unnamed and will then search for it in the piping specialties part of the Piping Job
Specification by its AABBCC code, option and pertinent size range and will proceed to retrieve
applicable data about it.
One of the items retrieved from either the Instrument TDB or the Piping Job Specification is the
model code, which will include the definition of the graphic representation of the component in the
piping model.

Plant Design System (PDS) Piping Component Data

177

Commodity Discussions

Connect Point Data


Connect point dependent data about each component is organized in terms of green and red
connect points. So that the various sets of data that may exist about these connect points can
remain coordinated, the following conventions have been followed regarding the sequence of data
in the Instrument TDB and in the Piping Job Specification and regarding the naming of the
Interactive Data Tables:
If data is only shown under green connect point data, it applies to all ends of the component.
If the component has ends of two different nominal diameters, regardless of how the other end
properties compare, properties about the larger nominal diameter end(s) have been defined
under the green connect point data.
If the component has ends of the same nominal diameter but differing in some of the other end
properties, the following applies:
If the termination type of the ends differ, regardless of the values for schedule/thickness,
the properties of the end(s) with the lowest codelist number defining its CP preparation
have been defined under the green connect point data.
If the termination type of the ends are the same but the values for rating, schedule or
thickness differ, the properties of the stronger ends(s) have been defined under the green
connect point data.
For each control valve or regulator, dimensional data is defined in tables, as follows:
Named Instrument - If the component is named, regardless of its other characteristics, the
following applies:
Both generic and specific data about the component is included in the applicable unit of
the Instrument TDB.
Refer to the explanation given under table format I80 for details.
Unnamed Instrument, GCP=male - If the component is unnamed, if only green connect point
data appears in the definition of the component in the instrument specialties part of the Piping
Job Specification and if the connect point is a male termination type, the following applies:
Data about the component is included in a table with format I81. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Unnamed_I
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water,
weight of the actuator plus all those dimensional parameters required to display the
component and its actuator, if any, in the model whose values are not defined in a generic
table.

Unnamed Instrument, GCP male - If the component is unnamed, if only green connect
point data appears in the definition of the component in the instrument specialties part of the
Piping Job Specification and if the connect point is not a male termination type, the following
applies:
Data about the component is included in a table with format I85. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Rat(G) Unnamed_I
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water,
weight of the actuator plus all those dimensional parameters required to display the

178

Plant Design System (PDS) Piping Component Data

Commodity Discussions

component and its actuator, if any, in the model whose values are not defined in a generic
table.
Unnamed Instrument, GCP=bolted or female, RCP=male - If the component is unnamed, if
both green and red connect point data appears in the definition of the component in the
instrument specialties part of the Piping Job Specification, the green connect point is either a
bolted or a female termination type and the red connect point is a male termination type, the
following applies:
Data about the component is included in a table with format I95. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.

Unnamed Instrument, GCP male, RCP male - If the component is unnamed, if both
green and red connect point data appears in the definition of the component in the instrument
specialties part of the Piping Job Specification and neither the green nor the red connect
points are male termination types, the following applies:
Data about the component is included in a table with format I96. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.
Unnamed Instrument, GCP=male, RCP=male - If the component is unnamed, if both green
and red connect point data appears in the definition of the component in the instrument
specialties part of the Piping Job Specification and both the green and the red connect points
are male termination types, the following applies:
Data about the component is included in a table with format I91. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Term(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.

Unnamed Instrument, GCP=male, RCP male - If the component is unnamed, if both green
and red connect point data appears in the definition of the component in the instrument
specialties part of the Piping Job Specification, the green connect point is a male termination
type and the red connect point is not a male termination type, the following applies:
Data about the component is included in a table with format I97. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:

Plant Design System (PDS) Piping Component Data

179

Commodity Discussions
MC_GS_Term(G) Term(R) Rat(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.
Control valves and regulators will have actuators unless otherwise specifically indicated in
paragraphs that follow. Actuators are defined independent of the components unless otherwise
specifically indicated in paragraphs that follow. Refer to paragraph C6.1 for additional
requirements regarding actuators.
Control valves and regulators and their actuators will not be automatically placed during automatic
component placement. They will always be positioned by the User.
Reference to ends in component type definitions that follow refer to the applicable of in-line or tap
ends that might apply to the component.
Under the description of each table format applicable to each component type, the GCP and RCP
rating and schedule/thickness that needs to be provided in the Piping Job Specification has been
listed. These values are required for one or more of the reasons indicated below and will not
necessarily be part of the names of the tables that include data about the component.
To procure the component.
To access data tables. Refer to section Model Graphics Definitions for a description of the
table formats.
To supply data required for stress analysis purposes.
The following general comments apply to the use of symbols used to depict these
instruments:
The symbols shown below under each instrument type are only suggested symbols that
can be used to depict such instruments. Any instrument symbol defined in Paragraphs
C5.2, C5.3, C5.4 or C5.5 may be used instead.
Ensure that for each symbol used, a proper match has been to an Isogen symbol.
Unless specifically defined otherwise, symbols listed below have been defined so that
they can be placed either with or without actuators.
Taps may be placed during the design session as required to define connections whose
definition is not possible with the symbol chosen.
The AABBCC code for control valves and regulators will consist of the applicable AABB code,
7P1E, followed by two numbers for the specific instrument.

180

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7P1E01, [2-way generic body] control valve (in-line)


(P&ID instr comp type=72)
Any of the model codes for 2-way control valves may be used
under this AABBCC code.

7P1E02, [2-way generic body] angle control valve (in-line)


(P&ID instr comp type=73)
Any of the model codes for 2-way angle control valves may be
used under this AABBCC code.

7P1E03, 3-way [generic body] control valve (in-line)


(P&ID instr comp type=74)
3-way generic valve type 1 (MC=I3AT or I3AS) (SN=I3AZ)

7P1E04, 4-way [generic body] control valve (in-line)


(P&ID instr comp type=75)
Any of the model codes for 4-way control valves may be used
under this AABBCC code.

7P1E05, [2-way] angle globe control valve (in-line)


(P&ID instr comp type=76)
Angle globe control valve type 1 (MC=I5AT or I5AS) (SN=I5AZ)

7P1E06, 3-way globe control valve (in-line)


(P&ID instr comp type=77)
3-way globe control valve type 1 (MC=I6AT or I6AS) (SN=I6AZ)

7P1E07, [2-way] solenoid valve (in-line)


(P&ID instr comp type=78)
Solenoid valve type 1 (MC=I7AT or I7AS)

Plant Design System (PDS) Piping Component Data

(SN=I7AZ)

181

Commodity Discussions

7P1E08, [2-way] angle solenoid valve (in-line)


(P&ID instr comp type=79)
Angle solenoid valve type 1 (MC=I5AT or I5AS) (SN=I5AZ)

7P1E09, 3-way solenoid valve (in-line)


(P&ID instr comp type=80)
Any of the model codes for 3-way control valves may be used
under this AABBCC code.

7P1E10, 4-way solenoid valve (in-line)


(P&ID instr comp type=81)
Any of the model codes for 4-way control valves may be used
under this AABBCC code.

7P1E11, 3-way plug control valve (in-line)


(P&ID instr comp type=82)
3-way plug control valve type 1 (MC=I11AT or I11AS)
(SN=I11AZ)

7P1E12, 4-way plug control valve (in-line)


(P&ID instr comp type=83)
4-way plug control valve type 1 (MC=I12AT or I12AS)
(SN=I12AZ)

7P1E13, [2-way] ball control valve (in-line)


(P&ID instr comp type=84)
Ball control valve type 1 (MC=I13AT or I13AS) (SN=I13AZ)

7P1E14, 3-way ball control valve (in-line)


(P&ID instr comp type=85)
3-way ball control valve type 1 (MC=I14AT or I14AS)
(SN=I14AZ)

182

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7P1E15, [2-way] globe control valve (in-line)


(P&ID instr comp type=86)
Globe control valve type 1 (MC=I15AT or I15AS) (SN=I15AZ)

7P1E16, [2-way] plug control valve (in-line)


(P&ID instr comp type=87)
Plug control valve type 1 (MC=I16AT or I16AS) (SN=I16AZ)

7P1E17, [2-way] butterfly control valve (in-line)


(P&ID instr comp type=88)
Butterfly control valve type 1 (MC=I17AT or I17AS)
(SN=I17AZ)

7P1E18, [2-way] knife gate control valve (in-line)


(P&ID instr comp type=89)
Knife gate control valve type 1 (MC=I17AT or I17AS)
(SN=I17AZ)

7P1E19, [2-way] diaphragm control valve (in-line)


(P&ID instr comp type=90)
Diaphragm control valve type 1 (MC=I7AT or I7AS) (SN=I7AZ)

7P1E20, [2-way] slide control valve (in-line)


(P&ID instr comp type=91)
Slide control valve type 1 (MC=I20AT or I20AS) (SN=I20AZ)

7P1E21, 3-way slide control valve (in-line)


(P&ID instr comp type=92)
3-way slide control valve type 1 (MC=Later) (SN=Later)

Plant Design System (PDS) Piping Component Data

183

Commodity Discussions

7P1E22, [2-way] multivane 1 damp/louv CV (in-line)


(P&ID instr comp type=93)
Multivane 1 damp/louv CV type 1 (MC=I17AT or I17AS)
(SN=I17AZ)

7P1E23, [2-way] multivane 2 damp/louv CV (in-line)


(P&ID instr comp type=94)
Multivane 2 damp/louv CV type 1 (MC=I17AT or I17AS)
(SN=I17AZ)

7P1E24, [2-way] single vane damp/louv CV (in-line)


(P&ID instr comp type=95)
Single vane damp/louv CV type 1 (MC=117AT or I17AS)
(SN=I17AZ)

7P1E27, Control valve w/equip (in-line)


(P&ID instr comp type=98)
This valve will not be represented in the 3D model.

7P1E30, Automatic recirculation valve (in-line)


(P&ID instr comp type=101)
Automatic recirculation valve type 1 (MC=I30AT or I30AS)
(SN=I30AZ)

7P1E33, Self contained press red reg (in-line)


(P&ID instr comp type=104)
Self contained press red reg type 1 (MC=I7AT or I7AS)
(SN=I7AZ)

184

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7P1E34, Press red reg w/ ext tap (in-line)


(P&ID instr comp type=105)
Press red reg w/ ext tap type 1 (MC=I7AT or I7AS) (SN=I7AZ)

7P1E35, Press red reg w/ int RV (in-line)


(P&ID instr comp type=106)
Press red reg w/ int RV type 1 (MC=I7AT or I7AS) (SN=I7AZ)

7P1E38, Self contained backpress reg (in-line)


(P&ID instr comp type=109)
Self contained backpress reg type 1 (MC=I7AT or I7AS)
(SN=I7AZ)

7P1E39, Backpress reg w/ ext tap (in-line)


(P&ID instr comp type=110)
Backpress reg w/ ext tap type 1 (MC=I7AT or I7AS) (SN=I7AZ)

7P1E42, Diff press red reg w/int & ext taps (in-line)
(P&ID instr comp type=113)
Diff press red reg w/int & ext taps type 1 (MC=I7AT or I7AS)
(SN=I7AZ)

7P1E44, [2-way] filled system temp reg (in-line)


(P&ID instr comp type=115)
Filled system temp reg type 1 (MC=I7AT or I7AS) (SN=I7AZ)

7P1E45, [2-way] angle filled system temp reg (in-line)


(P&ID instr comp type=116)
Angle filled system temp reg type 1 (MC=I5AT or I5AS)
(SN=I5AZ)

Plant Design System (PDS) Piping Component Data

185

Commodity Discussions

7P1E46, 3-way filled system temp reg (in-line)


(P&ID instr comp type=117)
3-way filled system temp reg type 1 (MC=I6AT or I6AS)
(SN=I6AZ)

Relief Devices (7P2C)


The AABBCC code for relief devices will consist of the applicable AABB code, 7P2C, followed by
two numbers for the specific device.
The Instrument Component Model Entity and the Instrument Component Analysis Entity will apply
to this class of instrument components.
Relief devices can be:
Connected to an equipment nozzle by direct mounting on it.
Connected to a pipeline by either:
Insertion in it
Direct mounting to the PCP of an in-line piping component
Direct mounting to the PCP of another in-line instrument component.
Placed unconnected.
It is possible either to insert these instrument components in the pipeline in which they belong with
the system breaking the line graphics as required (the system will rotate the instrument
component as dictated by the orientation of the line in which it is to be inserted); or to place these
components in free space and then pipe to them.
Relief devices will not be included in the piping materials class of the line in which placed. They
are independent of piping materials class.

See Also
Named or Unnamed Relief Devices (on page 187)
Connect Point Data (on page 187)
7P2C01, Angle press relief valve (in-line) (on page 190)
7P2C06, Straight-thru press relief valve (in-line) (on page 190)
7P2C09, Vac relief valve (in-line) (on page 190)
7P2C12, Press/vac relief valve (in-line) (on page 191)
7P2C14, Press/vac relief manhole cover (in-line) (on page 191)
7P2C16, Press relief rupture disc (in-line) (on page 191)
7P2C18, Vac relief rupture disc (in-line) (on page 191)
7P2C20, Temp fusible plug or disc (in-line) (on page 191)

186

Plant Design System (PDS) Piping Component Data

Commodity Discussions

Named or Unnamed Relief Devices


Relief devices can be either named or unnamed, as follows:
Named components are those components to which a project unique name, called component
number, is assigned by the User in the Piping TDB AND whose dimensional data has been
defined in the applicable unit of the Instrument Task.
Unnamed components are those components to which either a component number has not
been assigned by the User in the Piping TDB and/or whose dimensional data has not been
defined in the applicable unit of the Instrument Task. During the design process, it is possible
for a relief device to first be considered unnamed and then named, and vice versa. Data
about unnamed relief devices will be stored in the instrument specialties part of the Piping Job
Specification. The primary access key to named relief devices will be their AABBCC code.
An AABBCC code may be considered as a generic code about which a more detailed
definition is made in the Piping Job Specification. Depending upon the circumstances:
One or more model codes may be assigned to one AABBCC code, or
The same model code may be assigned to different AABBCC codes.
The system will first search for dimensional data about the relief device in the Instrument TDB. In
this search, the system will try to match the component number of the relief device with the tag
number assigned to it in the Instrument TDB. If dimensional data about the component is found,
the system will assume the component to be named and will proceed to retrieve dimensional data
about it.
If either the component or dimensional data about it is not found, the system will conclude that the
component is unnamed and will then search for it in the piping specialties part of the Piping Job
Specification by its AABBCC code, option and pertinent size range and will proceed to retrieve
applicable data about it.
One of the items retrieved from either the Instrument TDB or the Piping Job Specification is the
model code, which will include the definition of the graphic representation of the component in the
piping model.

Connect Point Data


Connect point dependent data about each component is organized in terms of green and red
connect points. So that the various sets of data that may exist about these connect points can
remain coordinated, the following conventions have been followed regarding the sequence of data
in the Instrument TDB and in the Piping Job Specification and regarding the naming of the
Interactive Data Tables:
If data is only shown under green connect point data, it applies to all ends of the component.
If the component has ends of two different nominal diameters, regardless of how the other end
properties compare, properties about the larger nominal diameter end(s) have been defined
under the green connect point data.
If the component has ends of the same nominal diameter but differing in some of the other end
properties, the following applies:
If the termination type of the ends differ, regardless of the values for schedule/thickness, the
properties of the end(s) with the lowest codelist number defining its CP preparation have been
defined under the green connect point data.
If the termination type of the ends are the same but the values for rating, schedule or thickness
differ, the properties of the stronger ends(s) have been defined under the green connect point
data.
For each relief device, dimensional data is defined in tables, as follows:

Plant Design System (PDS) Piping Component Data

187

Commodity Discussions

Named Instruments - If the component is named, regardless of its other characteristics, the
following applies:
Both generic and specific data about the component is included in the applicable unit of the
Instrument TDB.
Refer to the explanation given under table format I80 for details.
Unnamed Instrument, GCP=male - If the component is unnamed, if only green connect point
data appears in the definition of the component in the instrument specialties part of the Piping
Job Specification and if the connect point is a male termination type, the following applies:
Data about the component is included in a table with format I81. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Unnamed_I
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water,
weight of the actuator plus all those dimensional parameters required to display the
component and its actuator, if any, in the model whose values are not defined in a generic
table.

Unnamed Instrument, GCP male - If the component is unnamed, if only green connect
point data appears in the definition of the component in the instrument specialties part of the
Piping Job Specification and if the connect point is not a male termination type, the following
applies:
Data about the component is included in a table with format I85. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Rat(G) Unnamed_I
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water,
weight of the actuator plus all those dimensional parameters required to display the
component and its actuator, if any, in the model whose values are not defined in a generic
table.
Unnamed Instrument, GCP=bolted or female, RCP=male - If the component is unnamed, if
both green and red connect point data appears in the definition of the component in the
instrument specialties part of the Piping Job Specification, the green connect point is either a
bolted or a female termination type and the red connect point is a male termination type, the
following applies:
Data about the component is included in a table with format I95. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.

188

Unnamed Instrument, GCP male, RCP male - If the component is unnamed, if both
green and red connect point data appears in the definition of the component in the instrument
specialties part of the Piping Job Specification and neither the green nor the red connect
points are male termination types, the following applies:

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Data about the component is included in a table with format I96. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) Unnamed_I

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.
Unnamed Instrument, GCP=male, RCP=male - If the component is unnamed, if both green
and red connect point data appears in the definition of the component in the instrument
specialties part of the Piping Job Specification and both the green and the red connect points
are male termination types, the following applies:
Data about the component is included in a table with format I91. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Term(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.

Unnamed Instrument, GCP=male, RCP male - If the component is unnamed, if both green
and red connect point data appears in the definition of the component in the instrument
specialties part of the Piping Job Specification, the green connect point is a male termination
type and the red connect point is not a male termination type, the following applies:
Data about the component is included in a table with format I97. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC_GS_Term(G) Term(R) Rat(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water, weight of the actuator plus all those dimensional parameters required to
display the component and its actuator, if any, in the model whose values are not defined in a
generic table.
Relief devices will have actuators unless otherwise specifically indicated in paragraphs that
follow. Actuators are defined independent of the components unless otherwise specifically
indicated in paragraphs that follow. Refer to paragraph C.6.1 for additional requirements
regarding actuators.
Relief devices and their actuators will not be automatically placed during automatic
component placement. They will always be positioned by the User.
Reference to ends in component type definitions that follow refer to the applicable of in-line or
tap ends that might apply to the component.
Under the description of each table format applicable to each component type, the GCP and
RCP rating and schedule/thickness that needs to be provided in the Piping Job Specification
has been listed. These values are required for one or more of the reasons indicated below and
will not necessarily be part of the names of the tables that include data about the component.
To procure the component.

Plant Design System (PDS) Piping Component Data

189

Commodity Discussions

To access data tables. Refer to section Model Graphics Definitions for a description of the
table formats.
To supply data required for stress analysis purposes.
The following general comments apply to the use of symbols used to depict these
instruments:
The symbols shown below under each instrument type are only suggested symbols that
can be used to depict such instruments. Any instrument symbol defined in Paragraphs
C5.2, C5.3, C5.4 or C5.5 may be used instead.
Ensure that for each symbol used, a proper match has been to an Isogen symbol.
Unless specifically defined otherwise, symbols listed below have been defined so that
they can be placed either with or without actuators.
Taps may be placed during the design session as required to define connections whose
definition is not possible with the symbol chosen.
The AABBCC code for relief devices will consist of the applicable AABB code, 7P2C, followed by
two numbers for the specific device.

7P2C01, Angle press relief valve (in-line)


(P&ID instr comp type=138)
Angle press relief valve type 1 (MC=I8AT or I8AS) (SN=I8AZ)

7P2C06, Straight-thru press relief valve (in-line)


(P&ID instr comp type=143)
Straight-thru press relief valve type 1 (MC=I7AT or I7AS)
(SN=I7AZ)
Straight-thru press relief valve type 2 (no actuator)
(MC=I106BT or I106BS) (SN=I106BZ)

7P2C09, Vac relief valve (in-line)


(P&ID instr comp type=146)
Vac relief valve type 1 (MC=I8AT or I8AS) (SN=I8AZ)
Vac relief valve type 2 (no actuator) (MC=I109BT or I109BS)
(SN=I109BZ)
Vac relief valve type 3 (no actuator) (MC=I106BT or I106BS)
(SN=I106BZ)

190

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7P2C12, Press/vac relief valve (in-line)


(P&ID instr comp type=149)
Press/vac relief valve type 1 (MC=I8AT or I8AS) (SN=I8AZ)

7P2C14, Press/vac relief manhole cover (in-line)


(P&ID instr comp type=151)
Press/vac relief manhole cover type 1 (no actuator)
(MC=I106BT or I106BS) (SN=I106BZ)

7P2C16, Press relief rupture disc (in-line)


(P&ID instr comp type=153)
Press relief rupture disc type 1 (MC=I18AT or I18AS)
(SN=I18AZ)

7P2C18, Vac relief rupture disc (in-line)


(P&ID instr comp type=155)
Vac relief rupture disc type 1 (MC=I18AT or I18AS)
(SN=I18AZ)
Vac relief rupture disc type 2 (no actuator) (MC=I118BT or
I118BS) (SN=I118BZ)

7P2C20, Temp fusible plug or disc (in-line)


(P&ID instr comp type=157)
Temp fusible plug or disc type 1 (no actuator) (MC=I120AT or
I120AS) (SN=I120AZ)

Other in-line Instruments (7P3C)


The AABBCC code for other in-line instruments consists of the applicable AABB code, 7P3C,
followed by two numbers for the specific instrument.
The Instrument Component Model Entity and the Instrument Component Analysis Entity will apply
to this class of instrument components.
Other in-line instruments may be:
Connected to an equipment nozzle by direct mounting on it.
Connected to a pipeline by either:
Insertion in it
Direct mounting to the PCP of an in-line piping component
Direct mounting to the PCP of another in-line instrument component.
Placed unconnected.

Plant Design System (PDS) Piping Component Data

191

Commodity Discussions
It is possible either to insert these instrument components in the pipeline in which they belong with
the system breaking the line graphics as required (the system will rotate the instrument
component as dictated by the orientation of the line in which it is to be inserted); or to place these
components in free space and then pipe to them.
Other in-line instruments will not be included in the piping materials class of the line in which
placed. They are independent of piping materials class.

See Also
Named or Unnamed Instruments (on page 192)
Connect Point Data (on page 193)
7P3C01, Balloon instr (in-line) (on page 196)
7P3C02, Restriction orif union (in-line) (on page 196)
7P3C03, Valve w/restriction orif (in-line) (on page 196)
7P3C04, Orif plate (in-line) (on page 196)
7P3C05, Orif plate & flanges (in-line) (on page 196)
7P3C06, Orif plate, flanges & meter run (in-line) (on page 197)
7P3C09, Orif plate & qk chnge fitting (in-line) (on page 197)
7P3C10, Orif pl, qk chnge fitting & met run (in-line) (on page 197)
7P3C13, Venturi tube (in-line) (on page 197)
7P3C16, In-line averaging pitot tube (in-line) (on page 197)
7P3C19, Flow nozzle (in-line) (on page 197)
7P3C22, Var area flow instr (in-line) (on page 198)
7P3C23, Var area flow instr w/upstr reg (in-line) (on page 198)
7P3C24, Var area flow instr w/dwnstr reg (in-line) (on page 198)
7P3C25, Var area flow instr w/upstr vlv (in-line) (on page 198)
7P3C26, Var area flow instr w/dwnstr vlv (in-line) (on page 198)
7P3C29, Pos displacement flow instr (in-line) (on page 198)
7P3C30, Pos displ flow instr w/dwnstr reg (in-line) (on page 199)
7P3C33, In-line target flow instr (in-line) (on page 199)
7P3C35, In-line propeller flow instr (in-line) (on page 199)
7P3C37, Vortex flow instr (in-line) (on page 199)
7P3C39, In-line magnetic flow instr (in-line) (on page 199)
7P3C41, In-line ultrasonic flow instr (in-line) (on page 199)
7P3C44, Flume (in-line) (on page 200)
7P3C46, Weir (in-line) (on page 200)
7P3C48, Segmental wedge (in-line) (on page 200)
7P3C50, Flow straightening vane (in-line) (on page 200)
7P3C53, Trap (in-line) (on page 200)
7P3C56, Vent silencer (in-line) (on page 201)
7P3C57, In-line silencer (in-line) (on page 201)

Named or Unnamed Instruments


Other in-line instruments can be either named or unnamed, as follows:
Named components are those components to which a project unique name, called component
number, is assigned by the User in the Piping TDB AND whose dimensional data has been
defined in the applicable unit of the Instrument Task.
Unnamed components are those components to which either a component number has not
been assigned by the User in the Piping TDB and/or whose dimensional data has not been
defined in the applicable unit of the Instrument Task. During the design process, it is possible
for an other in-line instrument to first be considered unnamed and then named, and vice versa.
Data about unnamed other in-line instruments is stored in the instrument specialties part of the
Piping Job Specification. The primary access key to named other in-line instruments is their

192

Plant Design System (PDS) Piping Component Data

Commodity Discussions
AABBCC code. An AABBCC code may be considered as a generic code about which a more
detailed definition is made in the Piping Job Specification. Depending upon the
circumstances:
One or more model codes may be assigned to one AABBCC code, or
The same model code may be assigned to different AABBCC codes.
The system will first search for dimensional data about the other in-line instrument in the
Instrument TDB. In this search, the system will try to match the component number of the other
in-line instrument with the tag number assigned to it in the Instrument TDB. If dimensional data
about the component is found, the system will assume the component to be named and will
proceed to retrieve dimensional data about it.
If either the component or dimensional data about it is not found, the system will conclude that the
component is unnamed and will then search for it in the piping specialties part of the Piping Job
Specification by its AABBCC code, option and pertinent size range and will proceed to retrieve
applicable data about it.
One of the items retrieved from either the Instrument TDB or the Piping Job Specification is the
model code, which will include the definition of the graphic representation of the component in the
piping model.

Connect Point Data


Connect point dependent data about each component is organized in terms of green and red
connect points. So that the various sets of data that may exist about these connect points can
remain coordinated, the following conventions have been followed regarding the sequence of data
in the Instrument TDB and in the Piping Job Specification and regarding the naming of the
Interactive Data Tables:
If data is only shown under green connect point data, it applies to all ends of the component.
If the component has ends of two different nominal diameters, regardless of how the other end
properties compare, properties about the larger nominal diameter end(s) have been defined
under the green connect point data.
If the component has ends of the same nominal diameter but differing in some of the other end
properties, the following applies:
If the termination type of the ends differ, regardless of the values for schedule/thickness,
the properties of the end(s) with the lowest codelist number defining its CP preparation
have been defined under the green connect point data.
If the termination type of the ends are the same but the values for rating, schedule or
thickness differ, the properties of the stronger ends(s) have been defined under the green
connect point data.
For each other in-line instrument, dimensional data is defined in tables, as follows:
If the component is named, regardless of its other characteristics, the following applies:
Both generic and specific data about the component is included in the applicable unit of
the Instrument TDB.
Refer to the explanation given under table format I80 for details.
If the component is unnamed, if only green connect point data appears in the definition of the
component in the instrument specialties part of the Piping Job Specification and if the connect
point is a male termination type, the following applies:
Data about the component is included in a table with format I81. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Unnamed_I

Plant Design System (PDS) Piping Component Data

193

Commodity Discussions

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If the component is unnamed, if only green connect point data appears in the definition of the
component in the instrument specialties part of the Piping Job Specification and if the connect
point is not a male termination type, the following applies:
Data about the component is included in a table with format I85. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Rat(G) Unnamed_I
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification,
the green connect point is either a bolted or a female termination type and the red connect
point is a male termination type, the following applies:
Data about the component is included in a table with format I95. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification
and neither the green nor the red connect points are male termination types, the following
applies:
Data about the component is included in a table with format I96. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification
and both the green and the red connect points are male termination types, the following
applies:
Data about the component is included in a table with format I91. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Term(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,

194

Plant Design System (PDS) Piping Component Data

Commodity Discussions

weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification,
the green connect point is a male termination type and the red connect point is not a male
termination type, the following applies:
Data about the component is included in a table with format I97. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC_GS_Term(G) Term(R) Rat(R) Unnamed_I

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
Other in-line instruments will have not have actuators.
Other in-line instruments will not be automatically placed during automatic component placement.
They will always be positioned by the User.
Reference to ends in component type definitions that follow refer to the applicable of in-line or tap
ends that might apply to the component.
Under the description of each table format applicable to each component type, the GCP and RCP
rating and schedule/thickness that needs to be provided in the Piping Job Specification has been
listed. These values are required for one or more of the reasons indicated below and will not
necessarily be part of the names of the tables that include data about the component.
To procure the component.
To access data tables. Refer to Model Graphics Definitions for a description of the table
formats.
To supply data required for stress analysis purposes.
The following general comments apply to the use of symbols used to depict these
instruments:
The symbols shown below under each instrument type are only suggested symbols that
can be used to depict such instruments. Any instrument symbol defined in Paragraphs
C5.2, C5.3, C5.4 or C5.5 may be used instead.
Ensure that for each symbol used, a proper match has been to an Isogen symbol.
Unless specifically defined otherwise, symbols listed below have been defined so that
they can be placed either with or without actuators.
Taps may be placed during the design session as required to define connections whose
definition is not possible with the symbol chosen.
The AABBCC code for other in-line instruments consists of the applicable AABB code, 7P3C,
followed by two numbers for the specific instrument.

Plant Design System (PDS) Piping Component Data

195

Commodity Discussions

7P3C01, Balloon instr (in-line)


(P&ID instr comp type=171)
Balloon instr type 1 (no actuator) (MC=I201AT or I201AS)
(SN=I201AZ)
Balloon instr type 2 (MC=I201BT or I201BS) (SN=I201BZ)
Balloon instr type 3 (MC=I201CT or I201CS) (SN=I201CZ)
In addition, any of the model codes for other instruments
may be used under this AABBCC code.

7P3C02, Restriction orif union (in-line)


(P&ID instr comp type=172)
Restriction orif union type 1 (no actuator) (MC=I118BT or
I118BS) (SN=I118BZ)

7P3C03, Valve w/restriction orif (in-line)


(P&ID instr comp type=173)
Valve w/restriction orif type 1 (MC=I7AT or I7AS) (SN=I7AZ)

7P3C04, Orif plate (in-line)


(P&ID instr comp type=174)
Orif plate type 1 (MC=I18AT or I18AS) (SN=I18AZ)

7P3C05, Orif plate & flanges (in-line)


(P&ID instr comp type=175)
Orif plate & flanges type 1 (MC=I201BT or I201BS)
(SN=I201BZ)
It is assumed that gaskets and bolts are supplied by the
Instrument Vendor.

196

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7P3C06, Orif plate, flanges & meter run (in-line)


(P&ID instr comp type=176)
Orif plate, flanges & meter run type 1 (MC=I201BT or I201BS)
(SN=I201BZ)
It is assumed that gaskets and bolts are supplied by the
Instrument Vendor.

7P3C09, Orif plate & qk chnge fitting (in-line)


(P&ID instr comp type=179)
Orif plate & qk chnge fitting type 1 (MC=I209AT or I209AS)
(SN=I209AZ)

7P3C10, Orif pl, qk chnge fitting & met run (in-line)


(P&ID instr comp type=180)
Orif pl, qk chnge fitting & met run type 1 (MC=I201BT or
I201BS) (SN=I201BZ)
It is assumed that gaskets and bolts are supplied by the
Instrument Vendor.

7P3C13, Venturi tube (in-line)


(P&ID instr comp type=183)
Venturi tube type 1 (MC=I213AT or I213AS) (SN=I213AZ)

7P3C16, In-line averaging pitot tube (in-line)


(P&ID instr comp type=186)
In-line averaging pitot tube type 1 (MC=I216AT or I216AS)
(SN=I216AZ)

7P3C19, Flow nozzle (in-line)


(P&ID instr comp type=189)
Flow nozzle type 1 (MC=I219AT or I219AS) (SN=I219AZ)

Plant Design System (PDS) Piping Component Data

197

Commodity Discussions

7P3C22, Var area flow instr (in-line)


(P&ID instr comp type=192)
Var area flow instr type 1 (MC=I201BT or I201BS) (SN=I201BZ)
Var area flow instr type 2 (MC=I201CT or I201CS) (SN=I201CZ)
Var area flow instr type 3 (MC=I216AT or I216AS) (SN=I216AZ)

7P3C23, Var area flow instr w/upstr reg (in-line)


(P&ID instr comp type=193)
Var area flow instr w/upstr reg type 1 (MC=I201CT or I201CS)
(SN=I201CZ)

7P3C24, Var area flow instr w/dwnstr reg (in-line)


(P&ID instr comp type=194)
Var area flow instr w/dwnstr reg type 1 (MC=I209AT or
I209AS) (SN=I209AZ)

7P3C25, Var area flow instr w/upstr vlv (in-line)


(P&ID instr comp type=195)
Var area flow instr w/upstr vlv type 1 (MC=I201BT or I201BS)
(SN=I201BZ)

7P3C26, Var area flow instr w/dwnstr vlv (in-line)


(P&ID instr comp type=196)
Var area flow instr w/dwnstr vlv type 1 (MC=I201CT or
I201CS) (SN=I201CZ)

7P3C29, Pos displacement flow instr (in-line)


(P&ID instr comp type=199)
Pos displacement flow instr type 1 (MC=I216AT or I216AS)
(SN=I216AZ)
Pos displacement flow instr type 2 (MC=I201CT or I201CS)
(SN=I201CZ)

198

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7P3C30, Pos displ flow instr w/dwnstr reg (in-line)


(P&ID instr comp type=200)
Pos displ flow instr w/dwnstr reg type 1 (MC=I209AT or
I209AS) (SN=I209AZ)

7P3C33, In-line target flow instr (in-line)


(P&ID instr comp type=203)
In-line target flow instr type 1 (no actuator) (MC=I201AT or
I201AS) (SN=I201AZ)

7P3C35, In-line propeller flow instr (in-line)


(P&ID instr comp type=205)
In-line propeller flow instr type 1 (no actuator) (MC=I201AT
or I201AS) (SN=I201AZ)

7P3C37, Vortex flow instr (in-line)


(P&ID instr comp type=207)
Vortex flow instr type 1 (no actuator) (MC=I237AT or I237AS)
(SN=I237AZ)

7P3C39, In-line magnetic flow instr (in-line)


(P&ID instr comp type=209)
In-line magnetic flow instr type 1 (MC=I209AT or I209AS)
(SN=I209AZ)
In-line magnetic flow instr type 2 (no actuator) (MC=I237AT
or I237AS) (SN=I237AZ)

7P3C41, In-line ultrasonic flow instr (in-line)


(P&ID instr comp type=211)
In-line ultrasonic flow instr type 1 (MC=I209AT or I209AS)
(SN=I209AZ)

Plant Design System (PDS) Piping Component Data

199

Commodity Discussions

7P3C44, Flume (in-line)


(P&ID instr comp type=214)
This component is not used in the Piping Task.

7P3C46, Weir (in-line)


(P&ID instr comp type=216)
This component is not used in the Piping Task.

7P3C48, Segmental wedge (in-line)


(P&ID instr comp type=218)
Segmental wedge type 1 (MC=I201BT or I201BS) (SN=I201BZ)
It is assumed that gaskets and bolts within the instrument,
if any, is supplied by the Instrument Vendor.

7P3C50, Flow straightening vane (in-line)


(P&ID instr comp type=220)
Flow straightening vane type 1 (MC=I219AT or I219AS)
(SN=I219AZ)

7P3C53, Trap (in-line)


(P&ID instr comp type=223)
Steam trap type 1, (MC=I201BT or I201BS) (SN=I201BZ)
Steam trap type 2, (MC=I201CT or I201CS) (SN=I201CZ)
Steam trap type 3, (MC=I209AT or I209AS) (SN=I209AZ)
Steam trap type 4, (MC=I216AT or I216AS) (SN=I216AZ)
Steam trap type 5, (MC=I253AT or I253AS) (SN=I253AZ)

200

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7P3C56, Vent silencer (in-line)


(P&ID instr comp type=226)
Vent silencer type 1 (no actuator) (MC=I201BT or I201BS)
(SN=I201BZ)

7P3C57, In-line silencer (in-line)


(P&ID instr comp type=227)
In-line silencer type 1 (MC=I18AT or I18AS) (SN=I18AZ)
In-line silencer type 2 (no actuator) (MC=I201BT or I201BS)
(SN=I201BZ)

Off-Line Instruments (7Q4D)


The AABBCC code for off-line instruments will consist of the applicable AABB code, 7Q4D,
followed by two numbers for the specific instrument.
The Instrument Component Model Entity and the Instrument Component Analysis Entity will apply
to this class of instrument components.
Off-line instruments will never be inserted in a pipeline. They may be:
Connected to an equipment nozzle by:
Direct mounting on it
With a signal line.
Connected to a pipeline by:
Direct mounting on its surface
With a signal line.
Placed unconnected.
It is possible to place these components in free space and then pipe to them.
Off-line instruments will not be included in the piping materials class of the line in which placed.
They are independent of piping materials class.

See Also
Named or Unnamed Instruments (on page 203)
Connect Point Data (on page 203)
7Q4D01, Discrete [field mounted AE (off-line) (on page 206)
7Q4D02, Discrete [field mounted] AP (off-line) (on page 206)
7Q4D03, Discrete [field mounted] AT (off-line) (on page 206)
7Q4D06, Discrete [field mounted] FC (off-line) (on page 206)
7Q4D07, Discrete [field mounted] FI (off-line) (on page 206)
7Q4D08, Discrete [field mounted] FIC (off-line) (on page 206)
7Q4D09, Discrete [field mounted] FP (off-line) (on page 207)
7Q4D10, Discrete [field mounted] FR (off-line) (on page 207)
7Q4D11, Discrete [field mounted] FRC (off-line) (on page 207)
7Q4D12, Discrete [field mounted] FSH (off-line) (on page 207)
7Q4D13, Discrete [field mounted] FSL (off-line) (on page 207)
7Q4D14, Discrete [field mounted] FSM (off-line) (on page 207)
7Q4D15, Discrete [field mounted] FSHH (off-line) (on page 208)

Plant Design System (PDS) Piping Component Data

201

Commodity Discussions
7Q4D16, Discrete [field mounted] FSHL (off-line) (on page 208)
7Q4D17, Discrete [field mounted] FSLL (off-line) (on page 208)
7Q4D18, Discrete [field mounted] FT (off-line) (on page 208)
7Q4D21, Discrete [field mounted] LC (off-line) (on page 208)
7Q4D22, Discrete [field mounted] LG (off-line) (on page 209)
7Q4D23, Discrete [field mounted] LI (off-line) (on page 209)
7Q4D24, Discrete [field mounted] LIC (off-line) (on page 209)
7Q4D25, Discrete [field mounted] LR (off-line) (on page 210)
7Q4D26, Discrete [field mounted] LRC (off-line) (on page 210)
7Q4D27, Discrete [field mounted] LSH (off-line) (on page 210)
7Q4D28, Discrete [field mounted] LSL (off-line) (on page 210)
7Q4D29, Discrete [field mounted] LSM (off-line) (on page 210)
7Q4D30, Discrete [field mounted] LSHH (off-line) (on page 211)
7Q4D31, Discrete [field mounted] LSHL (off-line) (on page 211)
7Q4D32, Discrete [field mounted] LSLL (off-line) (on page 211)
7Q4D33, Discrete [field mounted] LT (off-line) (on page 211)
7Q4D35, Discrete [field mounted] PC (off-line) (on page 212)
7Q4D36, Discrete [field mounted] PDIC (off-line) (on page 212)
7Q4D37, Discrete [field mounted] PDSH (off-line) (on page 212)
7Q4D38, Discrete [field mounted] PDSL (off-line) (on page 212)
7Q4D39, Discrete [field mounted] PDT (off-line) (on page 212)
7Q4D40, Discrete [field mounted] PI (off-line) (on page 212)
7Q4D41, Discrete [field mounted] PIC (off-line) (on page 213)
7Q4D42, Discrete [field mounted] PP (off-line) (on page 213)
7Q4D43, Discrete [field mounted] PR (off-line) (on page 213)
7Q4D44, Discrete [field mounted] PRC (off-line) (on page 213)
7Q4D45, Discrete [field mounted] PSH (off-line) (on page 213)
7Q4D46, Discrete [field mounted] PSL (off-line) (on page 213)
7Q4D47, Discrete [field mounted] PSM (off-line) (on page 214)
7Q4D48, Discrete [field mounted] PSHH (off-line) (on page 214)
7Q4D49, Discrete [field mounted] PSHL (off-line) (on page 214)
7Q4D50, Discrete [field mounted] PSLL (off-line) (on page 214)
7Q4D51, Discrete [field mounted] PT (off-line) (on page 214)
7Q4D53, [Field mounted] pilot light (off-line) (on page 214)
7Q4D57, Discrete single-funct, [field mounted] instr (off-line) (on page 215)
7Q4D58, Discrete multi-funct, [field mounted] instr (off-line) (on page 215)
7Q4D60, Pilot light [accessible in primary location] (off-line) (on page 215)
7Q4D65, Discrete single-funct instr [accessible in primary location] (on page 215)
7Q4D66, Discrete multi-funct instr [accessible in primary location] (on page 215)
7Q4D70, Discrete single-funct instr [inaccessible in primary location] (off-line) (on page 215)
7Q4D71, Discrete multi-funct instr (on page 216)
7Q4D75, [2-way] solenoid valve [field mounted] (off-line) (on page 216)
7Q4D76, [2-way] angle solenoid valve [field mounted] (off-line) (on page 216)
7Q4D77, 3-way solenoid valve [field mounted] (off-line) (on page 216)
7Q4D78, 4-way single solenoid valve [field mounted] (off-line) (on page 216)
7Q4D79, 4-way double solenoid valve [field mounted] (off-line) (on page 216)
7Q4D80, Pilot light (on page 216)
7Q4D85, Discrete single-funct instr (on page 217)
7Q4D86, Discrete multi-funct instr (on page 217)
7Q4D88, Single port pitot tube [field mounted] (off-line) (on page 217)
7Q4D89, Pitot-venturi tube [field mounted] (off-line) (on page 217)
7Q4D90, Off-line averaging pitot tube [field mounted] (off-line) (on page 217)
7Q4D92, Off-line target flow instr [field mounted] (off-line) (on page 217)

202

Plant Design System (PDS) Piping Component Data

Commodity Discussions
7Q4D93, Off-line propeller flow instr [field mounted] (off-line) (on page 218)
7Q4D94, Off-line magnetic flow instr [field mounted] (off-line) (on page 218)
7Q4D95, Off-line ultrasonic flow instr [field mounted] (off-line) (on page 218)
7Q4D97, Discrete single-funct instr (on page 218)
7Q4D98, Discrete multi-funct instr (on page 218)

Named or Unnamed Instruments


Off-line instruments can be either named or unnamed, as follows:
Named components are those components to which a project unique name, called component
number, is assigned by the User in the Piping TDB AND whose dimensional data has been
defined in the applicable unit of the Instrument Task.
Unnamed components are those components to which either a component number has not
been assigned by the User in the Piping TDB and/or whose dimensional data has not been
defined in the applicable unit of the Instrument Task. During the design process, it is possible
for an off-line instrument to first be considered unnamed and then named, and vice versa.
Data about unnamed off-line instruments is stored in the instrument specialties part of the
Piping Job Specification. The primary access key to named off-line instruments is their
AABBCC code. An AABBCC code may be considered as a generic code about which a more
detailed definition is made in the Piping Job Specification. Depending upon the
circumstances:
One or more model codes may be assigned to one AABBCC code, or
The same model code may be assigned to different AABBCC codes.
The system will first search for dimensional data about the off-line instrument in the Instrument
TDB. In this search, the system will try to match the component number of the off-line instrument
with the tag number assigned to it in the Instrument TDB. If dimensional data about the
component is found, the system will assume the component to be named and will proceed to
retrieve dimensional data about it.
If either the component or dimensional data about it is not found, the system will conclude that the
component is unnamed and will then search for it in the piping specialties part of the Piping Job
Specification by its AABBCC code, option and pertinent size range and will proceed to retrieve
applicable data about it.
One of the items retrieved from either the Instrument TDB or the Piping Job Specification is the
model code, which will include the definition of the graphic representation of the component in the
piping model.

Connect Point Data


Connect point dependent data about each component is organized in terms of green and red
connect points. So that the various sets of data that may exist about these connect points can
remain coordinated, the following conventions have been followed regarding the sequence of data
in the Instrument TDB and in the Piping Job Specification and regarding the naming of the
Interactive Data Tables:
If data is only shown under green connect point data, it applies to all ends of the component.
If the component has ends of two different nominal diameters, regardless of how the other end
properties compare, properties about the larger nominal diameter end(s) have been defined
under the green connect point data.
If the component has ends of the same nominal diameter but differing in some of the other end
properties, the following applies:

Plant Design System (PDS) Piping Component Data

203

Commodity Discussions

If the termination type of the ends differ, regardless of the values for schedule/thickness,
the properties of the end(s) with the lowest codelist number defining its CP preparation
have been defined under the green connect point data.
If the termination type of the ends are the same but the values for rating, schedule or
thickness differ, the properties of the stronger ends(s) have been defined under the green
connect point data.
For each off-line instrument, dimensional data is defined in tables, as follows:
If the component is named, regardless of its other characteristics, the following applies:
Both generic and specific data about the component is included in the applicable unit of
the Instrument TDB.
Refer to the explanation given under table format I80 for details.
If the component is unnamed, if only green connect point data appears in the definition of the
component in the instrument specialties part of the Piping Job Specification and if the connect
point is a male termination type, the following applies:
Data about the component is included in a table with format I81. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Unnamed_I

204

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If the component is unnamed, if only green connect point data appears in the definition of the
component in the instrument specialties part of the Piping Job Specification and if the connect
point is not a male termination type, the following applies:
Data about the component is included in a table with format I85. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Rat(G) Unnamed_I
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are surface area, empty weight, weight of water
plus all those dimensional parameters required to display the component in the model whose
values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification,
the green connect point is either a bolted or a female termination type and the red connect
point is a male termination type, the following applies:
Data about the component is included in a table with format I95. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification
and neither the green nor the red connect points are male termination types, the following
applies:

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Data about the component is included in a table with format I96. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G)_Rat(G) Term(R)_Rat(R) Unnamed_I

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification
and both the green and the red connect points are male termination types, the following
applies:
Data about the component is included in a table with format I91. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC GS Term(G) Term(R) Unnamed_I
The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
If the component is unnamed, if both green and red connect point data appears in the
definition of the component in the instrument specialties part of the Piping Job Specification,
the green connect point is a male termination type and the red connect point is not a male
termination type, the following applies:
Data about the component is included in a table with format I97. The name of this table is
comprised of the following parameters from the instrument specialties part of the Piping Job
Specification:
MC_GS_Term(G) Term(R) Rat(R) Unnamed_I

The independent variables in this table are the nominal diameters of the green and red
connect points of the component. The dependent variables are surface area, empty weight,
weight of water plus all those dimensional parameters required to display the component in
the model whose values are not defined in a generic table.
Off-line instruments will have not have actuators.
Off-line instruments will not be automatically placed during automatic component placement.
They will always be positioned by the User.
Reference to ends in component type definitions that follow refer to the applicable of in-line or tap
ends that might apply to the component.
Under the description of each table format applicable to each component type, the GCP and RCP
rating and schedule/thickness that needs to be provided in the Piping Job Specification has been
listed. These values are required for one or more of the reasons indicated below and will not
necessarily be part of the names of the tables that include data about the component.
To procure the component.
To access data tables. Refer to Section 4, Model Graphics Definitions, for a description of
the table formats.
The following general comments apply to the use of symbols used to depict these
instruments:
The symbols shown below under each instrument type are only suggested symbols that
can be used to depict such instruments. Any instrument symbol defined in Paragraphs
C5.2, C5.3, C5.4 or C5.5 may be used instead.

Plant Design System (PDS) Piping Component Data

205

Commodity Discussions

Ensure that for each symbol used, a proper match has been to an Isogen symbol.
Unless specifically defined otherwise, symbols listed below have been defined so that
they can only be placed either without actuators.
Taps may be placed during the design session as required to define connections whose
definition is not possible with the symbol chosen.
The AABBCC code for off-line instruments will consist of the applicable AABB code, 7Q4D,
followed by two numbers for the specific instrument.

7Q4D01, Discrete [field mounted AE (off-line)


(P&ID instr comp type=232)
Analyzer type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D02, Discrete [field mounted] AP (off-line)


(P&ID instr comp type=233)
Analyzer sample point type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D03, Discrete [field mounted] AT (off-line)


(P&ID instr comp type=234)
Analyzer transmitter type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D06, Discrete [field mounted] FC (off-line)


(P&ID instr comp type=237)
Flow controller type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D07, Discrete [field mounted] FI (off-line)


(P&ID instr comp type=238)
Flow indicator type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D08, Discrete [field mounted] FIC (off-line)


(P&ID instr comp type=239)
Flow indicating controller type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

206

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7Q4D09, Discrete [field mounted] FP (off-line)


(P&ID instr comp type=240)
Flow test point type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D10, Discrete [field mounted] FR (off-line)


(P&ID instr comp type=241)
Flow recorder type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D11, Discrete [field mounted] FRC (off-line)


(P&ID instr comp type=242)
Flow recording controller type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D12, Discrete [field mounted] FSH (off-line)


(P&ID instr comp type=243)
Flow switch high type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D13, Discrete [field mounted] FSL (off-line)


(P&ID instr comp type=244)
Flow switch low type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D14, Discrete [field mounted] FSM (off-line)


(P&ID instr comp type=245)
Flow switch medium type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

Plant Design System (PDS) Piping Component Data

207

Commodity Discussions

7Q4D15, Discrete [field mounted] FSHH (off-line)


(P&ID instr comp type=246)
Flow switch high high type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D16, Discrete [field mounted] FSHL (off-line)


(P&ID instr comp type=247)
Flow switch high low type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D17, Discrete [field mounted] FSLL (off-line)


(P&ID instr comp type=248)
Flow switch low low type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D18, Discrete [field mounted] FT (off-line)


(P&ID instr comp type=249)
Flow transmitter type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D21, Discrete [field mounted] LC (off-line)


(P&ID instr comp type=252)
Level controller type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)
Level controller type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level controller type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

208

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7Q4D22, Discrete [field mounted] LG (off-line)


(P&ID instr comp type=253)
Level gage type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)
Level gage type 2 (with actuator), (MC=I201CT or I201CS)
(SN=I201CZ)
Level gage type 3 (with actuator), (MC=I253AT or I253AS)
(SN=I253AZ)
Level gage type 4, (MC=I322AT or I322AS) (SN=I322AZ)

7Q4D23, Discrete [field mounted] LI (off-line)


(P&ID instr comp type=254)
Level indicator type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D24, Discrete [field mounted] LIC (off-line)


(P&ID instr comp type=255)
Level indicating controller type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)
Level indicating controller type 2, upper and lower side
(with actuator) (MC=I253AT or I253AS) (SN=I253AZ)
Level indicating controller type 3, top-bottom (MC=I324CT or
I324CS) (SN=I324CZ)
Level indicating controller type 4, side-bottom (MC=I324DT
or I324DS) (SN=I324DZ)
Level indicating controller type 5, top-side (MC=I324ET or
I324ES) (SN=I324EZ)
Level indicating controller type 6, side-side (MC=I324FT or
I324FS) (SN=I324FZ)

Plant Design System (PDS) Piping Component Data

209

Commodity Discussions

7Q4D25, Discrete [field mounted] LR (off-line)


(P&ID instr comp type=256)
Level recorder type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D26, Discrete [field mounted] LRC (off-line)


(P&ID instr comp type=257)
Level recording controller type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

7Q4D27, Discrete [field mounted] LSH (off-line)


(P&ID instr comp type=258)
Level switch high type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)
Level switch high type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level switch high type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

7Q4D28, Discrete [field mounted] LSL (off-line)


(P&ID instr comp type=259)
Level switch low type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)
Level switch low type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level switch low type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

7Q4D29, Discrete [field mounted] LSM (off-line)


(P&ID instr comp type=260)
Level switch medium type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)
Level switch medium type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level switch medium type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

210

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7Q4D30, Discrete [field mounted] LSHH (off-line)


(P&ID instr comp type=261)
Level switch high high type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)
Level switch high high type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level switch high high type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

7Q4D31, Discrete [field mounted] LSHL (off-line)


(P&ID instr comp type=262)
Level switch high low type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)
Level switch high low type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level switch high low type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

7Q4D32, Discrete [field mounted] LSLL (off-line)


(P&ID instr comp type=263)
Level switch low low type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)
Level switch low low type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level switch low low type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

7Q4D33, Discrete [field mounted] LT (off-line)


(P&ID instr comp type=264)
Level transmitter type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)
Level transmitter type 2 (with actuator), (MC=I201CT or
I201CS) (SN=I201CZ)
Level transmitter type 3 (with actuator), (MC=I253AT or
I253AS) (SN=I253AZ)

Plant Design System (PDS) Piping Component Data

211

Commodity Discussions

7Q4D35, Discrete [field mounted] PC (off-line)


(P&ID instr comp type=266)
Pressure controller type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D36, Discrete [field mounted] PDIC (off-line)


(P&ID instr comp type=267)
Pressure differential indicating controller type 1
(MC=I301iT or I301iS, where i=A-J) (SN=I301AZ)

7Q4D37, Discrete [field mounted] PDSH (off-line)


(P&ID instr comp type=268)
Pressure differential switch high type 1 (MC=I301iT or
I301iS, where i=A-J) (SN=I301AZ)

7Q4D38, Discrete [field mounted] PDSL (off-line)


(P&ID instr comp type=269)
Pressure differential switch low type 1 (MC=I301iT or
I301iS, where i=A-J) (SN=I301AZ)

7Q4D39, Discrete [field mounted] PDT (off-line)


(P&ID instr comp type=270)
Pressure differential transmitter type 1 (MC=I301iT or
I301iS, where i=A-J) (SN=I301AZ)

7Q4D40, Discrete [field mounted] PI (off-line)


(P&ID instr comp type=271)
Pressure indicator type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

212

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7Q4D41, Discrete [field mounted] PIC (off-line)


(P&ID instr comp type=272)
Pressure indicating controller type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

7Q4D42, Discrete [field mounted] PP (off-line)


(P&ID instr comp type=273)
Pressure test point type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D43, Discrete [field mounted] PR (off-line)


(P&ID instr comp type=274)
Pressure recorder type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D44, Discrete [field mounted] PRC (off-line)


(P&ID instr comp type=275)
Pressure recording controller type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

7Q4D45, Discrete [field mounted] PSH (off-line)


(P&ID instr comp type=276)
Pressure switch high type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D46, Discrete [field mounted] PSL (off-line)


(P&ID instr comp type=277)
Pressure switch low type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

Plant Design System (PDS) Piping Component Data

213

Commodity Discussions

7Q4D47, Discrete [field mounted] PSM (off-line)


(P&ID instr comp type=278)
Pressure switch medium type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D48, Discrete [field mounted] PSHH (off-line)


(P&ID instr comp type=279)
Pressure switch high high type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D49, Discrete [field mounted] PSHL (off-line)


(P&ID instr comp type=280)
Pressure switch high low type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D50, Discrete [field mounted] PSLL (off-line)


(P&ID instr comp type=281)
Pressure switch low low type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D51, Discrete [field mounted] PT (off-line)


(P&ID instr comp type=282)
Pressure transmitter type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D53, [Field mounted] pilot light (off-line)


(P&ID instr comp type=284)
This instrument will not be represented in the 3D model.

214

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7Q4D57, Discrete single-funct, [field mounted] instr (off-line)


(P&ID instr comp type=288)
Discrete single-funct, field mounted instr type 1 (MC=I301iT
or I301iS, where i=A-J) (SN=I301AZ)

7Q4D58, Discrete multi-funct, [field mounted] instr (off-line)


(P&ID instr comp type=289)
This instrument will not be represented in the 3D model.

7Q4D60, Pilot light [accessible in primary location] (off-line)


(P&ID instr comp type=291)
This instrument will not be represented in the 3D model.

7Q4D65, Discrete single-funct instr [accessible in primary


location]
(off-line) (P&ID instr comp type=296)
This instrument will not be represented in the 3D model.

7Q4D66, Discrete multi-funct instr [accessible in primary


location]
(off-line) (P&ID instr comp type=297)
This instrument will not be represented in the 3D model.

7Q4D70, Discrete single-funct instr [inaccessible in primary


location] (off-line)
(P&ID instr comp type=301)
This instrument will not be represented in the 3D model.

Plant Design System (PDS) Piping Component Data

215

Commodity Discussions

7Q4D71, Discrete multi-funct instr


[inaccessible in primary location] (off-line)
(P&ID instr comp type=302)
This instrument will not be represented in the 3D model.

7Q4D75, [2-way] solenoid valve [field mounted] (off-line)


(P&ID instr comp type=306)
This instrument will not be represented in the 3D model.

7Q4D76, [2-way] angle solenoid valve [field mounted] (off-line)


(P&ID instr comp type=307)
This instrument will not be represented in the 3D model.

7Q4D77, 3-way solenoid valve [field mounted] (off-line)


(P&ID instr comp type=308)
This instrument will not be represented in the 3D model.

7Q4D78, 4-way single solenoid valve [field mounted] (off-line)


(P&ID instr comp type=309)
This instrument will not be represented in the 3D model.

7Q4D79, 4-way double solenoid valve [field mounted] (off-line)


(P&ID instr comp type=310)
This instrument will not be represented in the 3D model.

7Q4D80, Pilot light


[accessible in auxiliary location] (off-line)
(P&ID instr comp type=311)
This instrument will not be represented in the 3D model.

216

Plant Design System (PDS) Piping Component Data

Commodity Discussions

7Q4D85, Discrete single-funct instr


[accessible in auxiliary location]
(off-line) (P&ID instr comp type=316)
This instrument will not be represented in the 3D model.

7Q4D86, Discrete multi-funct instr


[accessible in auxiliary location]
(off-line) (P&ID instr comp type=317)
This instrument will not be represented in the 3D model.

7Q4D88, Single port pitot tube [field mounted] (off-line)


(P&ID instr comp type=319)
Single port pitot tube type 1 (MC=I301iT or I301iS, where
i=A-J) (SN=I301AZ)

7Q4D89, Pitot-venturi tube [field mounted] (off-line)


(P&ID instr comp type=320)
Pitot-venturi tube type 1 (MC=I301iT or I301iS, where i=A-J)
(SN=I301AZ)

7Q4D90, Off-line averaging pitot tube [field mounted] (off-line)


(P&ID instr comp type=321)
Off-line averaging pitot tube type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

7Q4D92, Off-line target flow instr [field mounted] (off-line)


(P&ID instr comp type=323)
Off-line target flow instr type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

Plant Design System (PDS) Piping Component Data

217

Commodity Discussions

7Q4D93, Off-line propeller flow instr [field mounted] (off-line)


(P&ID instr comp type=324)
Off-line propeller flow instr type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

7Q4D94, Off-line magnetic flow instr [field mounted] (off-line)


(P&ID instr comp type=325)
Off-line magnetic flow instr type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

7Q4D95, Off-line ultrasonic flow instr [field mounted] (off-line)


(P&ID instr comp type=326)
Off-line ultrasonic flow instr type 1 (MC=I301iT or I301iS,
where i=A-J) (SN=I301AZ)

7Q4D97, Discrete single-funct instr


[inaccessible in auxiliary location]
(off-line) (P&ID instr comp type=328)
This instrument will not be represented in the 3D model.

7Q4D98, Discrete multi-funct instr


[inaccessible in auxiliary location]
(off-line) (P&ID instr comp type=329)
This instrument will not be represented in the 3D model.

Miscellaneous
See Also
Valve Operators and Actuators (on page 219)
Piping Connectors (on page 228)

218

Plant Design System (PDS) Piping Component Data

Commodity Discussions

Valve Operators and Actuators


All piping commodity valves will have operators unless otherwise specifically indicated in
paragraph C.1.2. Piping specialty components will only have operators if specifically so indicated
in paragraph C.3.1.
Instrument specialty control valves and relief devices will have actuators unless otherwise
specifically indicated in paragraph C.5.2 and C.5.3. The remaining instrument specialty
components will not have actuators.
Data about operators/actuators is stored in the entity that applies to the component to which the
operator/actuator belongs.
The type of operators/actuators is defined, using codelist values from codelist set CL550,
"Operator/Actuator Type", in the "Mod" column of the piping commodities part of the Piping Job
Specification. If the operator/actuator is to be placed in the model, a "+" or no sign entry is made
for this value. If the operator/actuator is not to be placed in the model, the code for the
operator/actuator is defined as a "-" number. It is possible to change from the TDB the decision
made regarding placing or not placing the valve operator/actuator in the model. To change the
type of operator/actuator that applies to a valve, you will have to place a valve with either a
different AABBCC code or with the proper option.
Model codes and symbol names for valve operators will have values as defined below:
For operators with data derived from parameters in the applicable Piping Materials Class 2-24:
For model codes, by appending the characters "OP_" to the entry for operator type in the
"Mod" column of the Piping Materials Class. For example, if the value "3" is found in the
"Mod" column, the model code is OP_3 (and not OP_03 or OP3).
For symbol names, by using the symbol whose value is hardcoded in the definition of the
applicable model code.
For operators with data derived from the commodity codes of the valves to which they apply,
25-40:
For model codes, by appending the characters "OP_" to the operator type entry in the "Mod"
column of the Piping Materials Class. For example, if the value "33" is found in the "Mod"
column, the model code is OP_33 (and not OP33 or OP_331).
For symbol names, by appending the characters "OP_" to the operator code entry in the third
output column of the applicable table P60A. For example, if the value "331" is found in the
subject column, the symbol name is OP_331 (and not OP33 or OP331). Note that each size
for a given commodity code may be given a different operator code, and thus a different
symbol name, if so required.
For actuators, 41-99:
For model codes, by appending the characters "OP_" to the operator code entry in the "Mod"
column of the applicable Specialty Table. For example, if the value "411" is found in the
"Mod" column, the model code is OP_411 (and not OP_41 or OP411).
For symbol names, by appending the characters "OP_" to the operator code entry in
parameter "Y1" of the applicable P8*, P9*, I8* or I9* table. For example, if the value "411" is
found in the subject column, the symbol name will be OP_411 (and not OP41 or OP411).
For valve appurtenances:
For model codes, by changing the characters "OP_" to "A_" of the model code of the valve to
which the appurtenance is applied and by adding the number indicated below to the numeric
part of the valve model code.
Appurtenance

Number to be Added

Plant Design System (PDS) Piping Component Data

219

Commodity Discussions
Chainwheel

1000

Floor stand

2000

Extension stem
3000
For example, if a chainwheel is added to a gear operated valve having an operator model
code of OP_25, the model code for the new operator is A_1025.
For symbol names, by using the symbol whose value is hardcoded in the definition of the
applicable model code.
Data for operators/actuators is defined in tables, as follows:
For piping valves in the piping commodities part of the Piping Job Specification and whose
operator types are less than or equal to 24, dimensional data about the operator, regardless of
whether only GCP or both GCP and RCP data applies to the valve, is included in a table with
format P31A. The name of this table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_Type(G)_Rat(G) Op A
Where,
MC applies to the valve to which the operator belongs
Type will have the following possible values:
Preparation

Type

2-199

BLT

300-399

MAL

400-599
FEM
Op represents the absolute value of the entry for operator type made in the "Mod" column of
the Piping Materials Class.
The independent variable(s) in this table is:
For operator types 1-3 and 5-24: the nominal diameter of the green connect point of the
operator.
For operator type 4: the nominal diameters of the "green and of the red connect points of
the operator.
The dependent variables are those dimensional parameters required to display the valve
operator in the model. For these operators, no definition is made of the location of their
center of gravity.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters, the remaining parameters are included in a table with format P31B.
The name of the P31B table is comprised of the following parameters from the piping
commodities part of the Piping Job Specification:
MC_Type(G)_Rat(G) Op B

220

The only independent variable in this table is the nominal diameter of the green connect point
of the operator. The dependent variables are those dimensional parameters required to
display the valve operator in the model that were not included in the P31A table.
In general, data in these tables represents the largest dimensions resulting from a comparison
of operators supplied by common USA valve manufacturers.
For piping valves in the piping commodities part of the Piping Job Specification and whose
operator types exceed 24 and are less than or equal to 40, the empty weight of the valve
exclusive of the operator weight, the operator weight, the operator code of the valve operator,
the three parameters that define the location of the center of gravity of the operator and up to

Plant Design System (PDS) Piping Component Data

Commodity Discussions
two dimensional parameters required to define the geometry of the valve operator, regardless
of whether only GCP or both GCP and RCP data apply to the valve, is included in a table with
format P60A. The name of this table is comprised of the following parameter from the piping
commodities part of the Piping Job Specification:
Cmdty Code_WOPD_A
The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are the empty weight of the valve exclusive of
the operator weight, the operator weight, the operator code of the valve operators, the three
parameters that define the location of the center of gravity of the operator and up to two
dimensional parameters required to define the geometry of the valve operator.
If columns available in the above table were insufficient to allow definition of all the applicable
dimensional parameters of the valve operator, the remaining parameters is included in a table
with format P60B. The name of the P60B table is comprised of the following parameter from
the piping commodities part of the Piping Job Specification:
Cmdty Code_WOPD_B

The only independent variable in this table is the nominal diameter of the green connect point
of the component. The dependent variables are those dimensional parameters required to
display the valve operator in the model that were not included in the P60A table.
In general, data in these tables represent the dimensions applicable to the valve described in
the corresponding short description. You should check these tables to make sure that
dimensions given are suitable to the project for which they are intended.
For piping valves in the piping specialties part of the Piping Job Specification whose operator
types exceed 40 and for all instrument valves, all applicable data about the valve, the operator
weight, the operator code (parameter Y1), the three parameters that define the location of the
center of gravity of the operator and all the dimensional parameters required to define the
geometry of the valve operator, regardless of whether only GCP or both GCP and RCP data
apply to the valve, is included in a table with format P80 for piping valves or I80 for instrument
valves. The name of this table is:
Named_Pipe_Specialties, for piping valves
Named_Instr_Specialties, for instrument valves

The only independent variable in this table is the component number of the component. The
dependent variables is all the applicable data about the valve, the operator weight, the
operator code (parameter Y1), the three parameters that define the location of the center of
gravity of the operator and all the dimensional parameters required to define the geometry of
the valve operator.
If at placement time, data was not found in the applicable of the tables defined above, the system
will prompt you for the values of all the parameters that would otherwise be found in the data table.
At this time, a tutorial defining the applicable parameters is displayed. The values you define
are be stored by the system for use in subsequent model reconstruction. The values so stored
will not be used in future model reconstructions after the applicable data tables are prepared.
Valve operators will not be automatically placed during automatic component placement. They
will always be positioned by you.
In the list that follows, types 2-24 apply to operators for piping commodity valves whose
dimensions are determined from tables whose names are formed from attributes in the Piping Job
Specification. Types 25-40 apply to operators for piping commodity valves whose dimensions
are determined from tables whose names depend on the commodity codes for the valves. Types
41-99 apply to operators/actuators for piping and instrument specialty valves.

Plant Design System (PDS) Piping Component Data

221

Commodity Discussions
Operators with Data Derived from Parameters in the Applicable Piping Materials Class, 2-24:
Type 03, Handwheel (OT=3), (OC=3), (MC=OP_3, A_1003, A_2003 & A_3003), (SN=OP3,
A1003, S2003 & S3003) (TNF=P31A)
This operator may be placed with or without appurtenances. The default placement is without
appurtenances and is represented by symbol OP3. At any time after placement, the you can add
any one of the appurtenances indicated in the table below by executing the placement command
listed in it. This will cause the existing operator to be deleted and a new operator to be created
whose shape is represented by the symbol listed in the table.
Appurtenance
Placement Command
Symbol
None
Default
OP3
Chainwheel
Add Chainwheel
A1003
Floor stand
Add Floorstand
S2003
Extension stem
Add Extension Stem
S3003
In response to one of the add appurtenance commands, the system will prompt the you for
user-defined information applicable to the indicated appurtenance, as follows:
Appurtenance
Data Prompted
Chainwheel
Total length of chain
Floorstand
"Y1", "Y2", "Y3", "Y4"
Extension stem
"Y1", "Y2"
Further action by the system will depend upon the type of appurtenance involved, as follows:
For chainwheels: the data table that applies to symbol OP3 is used for the definition of the
A1003 symbol. The value for chainwheel height required by symbol A1003 is determined by
the system on the basis of instructions given in note 64.
For floorstands and extension stems: no data table will apply. You are prompted to provide
all the information required to place the symbol involved.
All parameters you provide in the definition of operator appurtenances are remembered by the
system for use during model reconstruction.
It is possible to include in the iso and in reports data required for the purchase of operator
appurtenances. The reports will include, in addition to all the parameters you provide at
placement time, the following data about the valve: the applicable line number, piping materials
class, nominal diameter, commodity code and the three applicable coordinates locating the valve
origin in the model.
Type 04, Handwheel if GCP > RCP (OT=4), (OC=4), (MC=OP_4), (SN=OP4 (TNF=P31A)
This operator is identical in all respects 0o the one described under Type 03, except that:
The table that is used to store the operator dimensions has both the GCP and the RCP
diameters as input. This operator is used for components such as extended body olet valves
whose definition require different values for the diameters of the GCP and RCP.
No data provisions have been made to allow the placement of appurtenances, such as
chainwheels, on this operator.
Type 05, Handwheel, inclined (OT=5), (OC=5), (MC=OP_5, EA_1005), (SN=OP5, A1005)
(TNF=P31A)
This operator may be placed with or without appurtenances. The default placement is without
appurtenances and is represented by symbol OP5. At any time after placement, you can any one
of the appurtenances indicated in the table below by executing the placement command listed in
it. This will cause the existing operator to be deleted and a new operator to be created whose
shape is represented by the symbol listed in the table.
Appurtenance
Placement Command
Symbol
None
Default
OP5
Chainwheel
Add Chainwheel
A1005

222

Plant Design System (PDS) Piping Component Data

Commodity Discussions
In response to one of the add appurtenance commands, the system will prompt you for
user-defined information applicable to the indicated appurtenance, as follows:
Appurtenance
Data Prompted
Chainwheel
Total length of chain
Further action by the system will depend upon the type of appurtenance involved, as follows:
For chainwheels: the data table that applies to symbol OP5 is used for the definition of the
A1005 symbol. The value for chainwheel height required by symbol A1005 is determined by
the system on the basis of instructions given in note 64.
All parameters you provide in the definition of operator appurtenances are remembered by the
system for use during model reconstruction.
It is possible to include in the iso and in reports data required for the purchase of operator
appurtenances. The reports will include, in addition to all the parameters you provide at
placement time, the following data about the valve: the applicable line number, piping materials
class, nominal diameter, commodity code and the three applicable coordinates locating the valve
origin in the model.
Type 09, Wrench, short (OT=9), (OC=9), (MC=OP_9), (SN=OP9), (TNF=P31A)
Type 11, Wrench, long (OT=11), (OC=11), (MC=OP_11), (SN=OP9), (TNF=P31A)
Type 17, Lever (OT=17), (OC=17), (MC=OP_17), (SN=OP9), (TNF=P31A)
Type 19, T-handle, short (OT=19), (OC=19), (MC=OP_19, A_2019 & A_3019), (SN=OP9,
S2003 & S3003) (TNF=P31A)
This operator may be placed with or without appurtenances. The default placement is without
appurtenances and is represented by symbol OP9. At any time after placement, you can add any
one of the appurtenances indicated in the table below by executing the placement command listed
in it. This will cause the existing operator to be deleted and a new operator to be created whose
shape is represented by the symbol listed in the table.
Appurtenance
Placement Command
Symbol
None
Default
OP9
Floor stand
Add Floorstand
S2003
Extension stem
Add Extension Stem
S3003
In response to one of the add appurtenance commands, the system will prompt you for
user-defined information applicable to the indicated appurtenance, as follows:
Appurtenance
Data Prompted
Floorstand
"Y1", "Y2", "Y3", "Y4"
Extension stem
"Y1", "Y2"
Further action by the system will depend upon the type of appurtenance involved, as follows:
For floorstands and extension stems: no data table will apply. You are prompted to provide
all the information required to place the symbol involved.
All parameters you provide in the definition of operator appurtenances are remembered by the
system for use during model reconstruction.
It is possible to include in the iso and in reports data required for the purchase of operator
appurtenances. The reports will include, in addition to all the parameters you provide at
placement time, the following data about the valve: the applicable line number, piping materials
class, nominal diameter, commodity code and the three applicable coordinates locating the valve
origin in the model.
Type 21, T-handle, long (OT=21), (OC=21), (MC=OP_21, A_2021 & A_3021), (SN=OP9,
S2003 & S3003) (TNF=P31A)
This operator may be placed with or without appurtenances. The default placement is without
appurtenances and is represented by symbol OP9. At any time after placement, you can add any

Plant Design System (PDS) Piping Component Data

223

Commodity Discussions
one of the appurtenances indicated in the table below by executing the placement command
listed in it. This will cause the existing operator to be deleted and a new operator to be created
whose shape is represented by the symbol listed in the table.
Appurtenance
Placement Command
Symbol
None
Default
OP9
Floor stand
Add Floorstand
S2003
Extension stem
Add Extension Stem
S3003
In response to one of the add appurtenance commands, the system will prompt you for
user-defined information applicable to the indicated appurtenance, as follows:
Appurtenance
Data Prompted
Floorstand
"Y1", "Y2", "Y3", "Y4"
Extension stem
"Y1", "Y2"
Further action by the system will depend upon the type of appurtenance involved, as follows:
For floorstands and extension stems: no data table will apply. You are prompted to provide
all the information required to place the symbol involved.
All parameters you provide in the definition of operator appurtenances are remembered by the
system for use during model reconstruction.
It is possible to include in the iso and in reports data required for the purchase of operator
appurtenances. The reports will include, in addition to all the parameters you provide at
placement time, the following data about the valve: the applicable line number, piping materials
class, nominal diameter, commodity code and the three applicable coordinates locating the valve
origin in the model.

Operators with Data Derived from the Commodity Codes of the Valves to Which They Apply,
25-40
Type 25, Handwheel, special (TNF=P60A & P60B)
Handwheel, special type 1 (OT=25), (OC=251), (MC=OP_25, A_1025, A_2025 & A_3025),
(SN=OP_251, A1251, S2003 & S3003)
This operator can be placed with or without appurtenances. The default placement is without
appurtenances and is represented by symbol OP_251. At any time after placement, the You can
add any one of the appurtenances indicated in the table below by executing the placement
command listed in it. This will cause the existing operator to be deleted and a new operator to be
created whose shape is represented by the symbol listed in the table.
Appurtenance
Placement Command
Symbol
None
Default
OP_251
Chainwheel
Add Chainwheel
A1251
Floor stand
Add Floorstand
S2003
Extension stem
Add Extension Stem
S3003
In response to one of the add appurtenance commands, the system will prompt you for
user-defined information applicable to the indicated appurtenance, as follows:
Appurtenance
Data Prompted
Chainwheel
Total length of chain
Floorstand
"Y1", "Y2", "Y3", "Y4"
Extension stem
"Y1", "Y2"
Further action by the system will depend upon the type of appurtenance involved, as follows:
For chainwheels: the data table that applies to symbol OP_251 is used for the definition of
the A1251 symbol. The value for chainwheel height required by symbol A1251 is determined
by the system on the basis of instructions given in note 64.

224

Plant Design System (PDS) Piping Component Data

Commodity Discussions

For floorstands and extension stems: no data table will apply. You are prompted to provide
all the information required to place the symbol involved.
All parameters you provide in the definition of operator appurtenances are remembered by the
system for use during model reconstruction.
It is possible to include in the iso and in reports data required for the purchase of operator
appurtenances. The reports will include, in addition to all the parameters you provide at
placement time, the following data about the valve: the applicable line number, piping materials
class, nominal diameter, commodity code and the three applicable coordinates locating the valve
origin in the model.
Type 27, Wrench, special (TNF=P60A & P60B)
Wrench, special type 1 (OT=27), (OC=271), (MC=OP_27), (SN=OP_271)
Type 29, Gear, top mounted handwheel (TNF=P60A & P60B)
Gear, top mounted handwheel type 1 (OT=29), (OC=291), (MC=OP_29), (SN=OP_291)
Gear, top mounted handwheel type 2 (OT=29), (OC=292), (MC=OP_29), (SN=OP_292)
Type 31, Gear, top mounted inclined handwheel (TNF=P60A & P60B)
Gear, top mounted inclined handwheel type 1 (OT=31), (OC=311), (MC=OP_31),
(SN=OP_311)
Type 33, Gear, side mounted handwheel (TNF=P60A & P60B)
Gear, side mounted handwheel type 1 (OT=33), (OC=331), (MC=OP_33, A_1033),
(SN=OP_331, A1331)
This operator may be placed with or without appurtenances. The default placement is without
appurtenances and is represented by symbol OP_331. At any time after placement, you can add
the appurtenance indicated in the table below by executing the placement command listed in it.
This will cause the existing operator to be deleted and a new operator to be created whose shape
is represented by the symbol listed in the table.
Appurtenance
Placement Command
Symbol
None
Default
OP_331
Chainwheel
Add Chainwheel
A1331
In response to the add appurtenance command, the system will prompt you for the following
user-defined information:
Appurtenance
Data Prompted
Chainwheel
Total length of chain
Further action by the system will depend upon the type of appurtenance involved, as follows:
For chainwheels: the data table that applies to symbol OP_331 is used for the definition of
the A1331 symbol. The value for chainwheel height required by symbol A1331 is determined
by the system on the basis of instructions given in note 64.
All parameters you provide in the definition of operator appurtenances are remembered by the
system for use during model reconstruction.
It is possible to include in the iso and in reports data required for the purchase of operator
appurtenances. The reports will include, in addition to all the parameters you provide at
placement time, the following data about the valve: the applicable line number, piping materials
class, nominal diameter, commodity code and the three applicable coordinates locating the valve
origin in the model.
Gear, side mounted handwheel type 2 (OT=33), (OC=332), (MC=OP_33, A_1033), (SN=OP_332,
A1332)
This operator may be placed with or without appurtenances. The default placement is without
appurtenances and is represented by symbol OP_332. At any time after placement, you can add
the appurtenance indicated in the table below by executing the listed placement command. This

Plant Design System (PDS) Piping Component Data

225

Commodity Discussions
will cause the existing operator to be deleted and a new operator to be created whose shape is
represented by the symbol listed in the table.
Appurtenance
Placement Command
Symbol
None
Default
OP_332
Chainwheel
Add Chainwheel
A1332
In response to the add appurtenance command, the system will prompt you for the following
user-defined information:
Appurtenance
Data Prompted
Chainwheel
Total length of chain
Further action by the system will depend upon the type of appurtenance involved, as follows:
For chainwheels: the data table that applies to symbol OP_332 is used for the definition of
the A1332 symbol. The value for chainwheel height required by symbol A1332 is determined
by the system on the basis of instructions given in note 64.
All parameters you provide in the definition of operator appurtenances are remembered by the
system for use during model reconstruction.
It is possible to include in the iso and in reports data required for the purchase of operator
appurtenances. The reports will include, in addition to all the parameters you provide at
placement, the following data about the valve: the applicable line number, piping materials class,
nominal diameter, commodity code and the three applicable coordinates locating the valve origin
in the model.
Gear, side mounted handwheel type 3 (OT=33), (OC=333), (MC=OP_33), (SN=OP_333)
Gear, side mounted handwheel type 4 (OT=33), (OC=334), (MC=OP_33), (SN=OP_334)
Type 35, Gear, side mounted inclined handwheel (TNF=P60A & P60B)
Gear, side mounted inclined handwheel type 1 (OT=35), (OC=351), (MC=OP_35),
(SN=OP_351)
Type 39, Lever, quick-action (TNF=P60A & P60B)
Lever, quick-action type 1 (OT=39), (OC=391), (MC=OP_39), (SN=OP_391)
Type 40, Post indicator (TNF=P60A)
Post indicator type 1 (OT=40), (OC=401), (MC=OP_40), (SN=OP_401)
For post indicators, the system will first prompt you for the value of parameter "Y6". It will then
proceed to read from the applicable data table the rest of the parameters required to place the
operator.
It is possible to include in the description of the valve to which this operator applies the value of
"Y6" you define. Actuators, 41-99
Type 41, Diaphragm (TNF=P8*, P9*, I8* or I9*)
Diaphragm type 1, no offset (OC=411), (MC=OP_411), (SN=OP_411)
Diaphragm type 2, no offset, inclined (OC=412), (MC=OP_412), (SN=OP_412)
Diaphragm type 3, with horizontal offset (OC=413), (MC=OP_413), (SN=OP_413)
Type 43, Press-balanced diaphragm (TNF=P8*, P9*, I8* or I9*)
Press-balanced diaphragm type 1, no offset (OC=431), (MC=OP_431), (SN=OP_411)
Press-balanced diaphragm type 2, no offset, inclined (OC=432), (MC=OP_432),
(SN=OP_412)
Press-balanced diaphragm type 3, with horizontal offset (OC=433), (MC=OP_433),
(SN=OP_413)
Type 45, Regulator (TNF=P8*, P9*, I8* or I9*)
Regulator type 1 (OC=451), (MC=OP_451), (SN=OP_451)

226

Plant Design System (PDS) Piping Component Data

Commodity Discussions
Regulator type 2 (OC=452), (MC=OP_452), (SN=OP_452)
Regulator type 3 (OC=453), (MC=OP_453), (SN=OP_453)
Type 49, Single acting cylinder (TNF=P8*, P9*, I8* or I9*) Single acting cylinder type 1
(OC=491), (MC=OP_491), (SN=OP_491)
Single acting cylinder type 2, inclined (OC=492), (MC=OP_492), (SN=OP_492)
Single acting cylinder type 3, w/vane and optional cylinder (OC=493), (MC=OP_493),
(SN=OP_493)
Single acting cylinder type 4, camflex (OC=494), (MC=OP_494), (SN=OP_494)
Type 51, Double acting cylinder (TNF=P8*, P9*, I8* or I9*)
Double acting cylinder type 1 (OC=511), (MC=OP_511), (SN=OP_491)
Double acting cylinder type 2, inclined (OC=512), (MC=OP_512), (SN=OP_492)
Double acting cylinder type 3, w/vane and optional cylinder (OC=513), (MC=OP_513),
(SN=OP_493)
Type 53, Pilot operated cylinder (TNF=P8*, P9*, I8* or I9*)
Pilot operated cylinder type 1 (OC=531), (MC=OP_531), (SN=OP_491)
Pilot operated cylinder type 2, inclined (OC=532), (MC=OP_532), (SN=OP_492)
Pilot operated cylinder type 3, w/vane and optional cylinder (OC=533), (MC=OP_533),
(SN=OP_493)
Pilot operated cylinder type 4 (OC=534), (MC=OP_534), (SN=OP_494)
Type 57, Motor (TNF=P8*, P9*, I8* or I9*)
Motor type 1 (OC=571), (MC=OP_571), (SN=OP_571)
Motor type 2 inclined (OC=572), (MC=OP_572), (SN=OP_572)
Motor type 3 (OC=573), (MC=OP_573), (SN=OP_573)
Motor type 4, inclined (OC=574), (MC=OP_574), (SN=OP_574)
Type 61, Digital (TNF=P8*, P9*, I8* or I9*)
Digital type 1 (OC=611), (MC=OP_611), (SN=OP_571)
Type 65, Electro-hydraulic (TNF=P8*, P9*, I8* or I9*)
Electro-hydraulic type 1 (OC=651), (MC=OP_651), (SN=OP_494)
Electro-hydraulic type 2 (OC=652), (MC=OP_652), (SN=OP_571)
Type 69, Single solenoid
This is not a valve actuator. It is an accessory to another actuator. The addition of this item to
an actuator would graphically be covered by the applicable actuator.
Type 71, Single solenoid w/reset
This is not a valve actuator. It is an accessory to another actuator. The addition of this item to
an actuator would graphically be covered by the applicable actuator.
Type 73, Double solenoid
This is not a valve actuator. It is an accessory to another actuator. The addition of this item to
an actuator would graphically be covered by the applicable actuator.
Type 77, Pilot
This is not a valve actuator. It is an accessory to another actuator. The addition of this item to
an actuator would graphically be covered by the applicable actuator.
Type 81, Weight (TNF=P8*, P9*, I8* or I9*)
Weight type 1 (OC=811), (MC=OP_811), (SN=OP_811)
Type 85, Manual (TNF=P8*, P9*, I8* or I9*)

Plant Design System (PDS) Piping Component Data

227

Commodity Discussions
Manual type 1 (OC=851), (MC=OP_851), (SN=OP_851)
Manual type 2, inclined (OC=852), (MC=OP_852), (SN=OP_852)
Manual type 3 (OC=853), (MC=OP_853), (SN=OP_853)
Manual type 4, inclined (OC=854), (MC=OP_854), (SN=OP_854)
Type 89, Spring (TNF=P8*, P9*, I8* or I9*)
Spring type 1 (OC=891), (MC=OP_891), (SN=OP_491)
Type 91, Capacitance sensor
This is not a valve actuator. It is an accessory to another actuator. The addition of this item to
an actuator would graphically be covered by the applicable actuator.
Type 93, Ball float (TNF=P8*, P9*, I8* or I9*)
No graphic symbol has been provided to represent this actuator.
Type 95, Displacement float
This is not a valve actuator. It is actually part of a level displacement transmitter which would
be shown with a balloon on the model.
Type 97, Paddle wheel
This is not a valve actuator. Should be only shown in the model by an instrument balloon.
Nothing would be modeled for this component.

Piping Connectors
See Also
Piping Utility Connector (6R9E) (on page 228)
Off-volume Piping Connectors (6R9G) (on page 228)
Off-Site Piping Connectors (6R9H) (on page 229)

Piping Utility Connector (6R9E)


The Piping Connector Entity applies to this class of components.
6R9E02, Drain connector
You can place drain connectors, implying connections to sewer systems. The placing and
labeling of these connectors are part of the same command. A requirement for these
connectors is that it be possible to connect more than one piping group to them.

Off-volume Piping Connectors (6R9G)


The Piping Connector Entity applies to this class of components. You can place off-volume
piping connectors to identify the continuation of piping segments in another design volume of the
same site. These connectors are defined at the same time that the component is placed.
6R9G12, To off-vol piping connector (directional)
6R9G16, From off-vol piping connector (directional)

228

Plant Design System (PDS) Piping Component Data

Commodity Discussions

Off-Site Piping Connectors (6R9H)


The Piping Connector Entity applies to this class of components. You can place off-site piping
connectors to identify the continuation of piping segments in another design volume of a different
site. These connectors are defined at the same time that the component is placed. The system
will not coordinate the matching of off-site connectors in any way.
6R9H12, To off-site piping connector (directional)
6R9H16, From off-site piping connector (directional)

6Q3C83, Non-radial Reinforcing Weld


Non-radial reinforcing weld (MC=RWELD) (SN=F182)
TNF=P29A & None
Beveled ends
For GCP: Rating="-"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"
This model code represents a nonradial branch reinforcing weld; that is one in which the pipe
terminates at the outside surface of the header.
Non-radial reinforcing weld (MC=RWELD2) (SN=F182)
TNF=P29A & None
Beveled ends
For GCP: Rating="-"; Sc/Th="-"
For RCP: Rating="-"; Sc/Th="-"
This model code represents a "stub-in" reinforcing weld; that is one in which the pipe terminates at
the inside surface of the header.
The following comments apply to all reinforcing welds:
Reinforcing welds are defined in the piping materials classes to have a fabrication category of
"-" since for them it is not possible to define this attribute. In the isometric drawings, a note is
placed in the graphic part of the drawing to show their size. A short description has been
prepared for reinforcing welds. The option not to display reinforcing welds in the bill of
materials is chosen, however, in the ISOGEN options file.
Reinforcing welds may be placed with either single or double curvature, for example
reinforcing a pipe or a head respectively.
The angle of intersection between the header and the branch is part of the table name
containing dimensional parameters for the component. This angle will be derived by the
system from data in the design file.
Four different types of intersection are recognized:
Intersections at angles equal to or greater than 20 but less than 45 degrees: the number
"2045" is used as part of the table name.
Intersections at 45 degrees: the number "45" is used as part of the table name.
Intersections at angles greater than 45 but lesser than 90 degrees: the number "4590" is
used as part of the table name.
Intersections at 90 degrees: the number "90" is used as part of the table name.
Two possibilities exist regarding dimensions for a reinforcing weld:
If a "0" is entered in the "MOD" column of the Piping Job Specification, dimensions are to
be derived from either a data table and/or from branch calculations.
For either case, a value is provided for the reinforcing weld size in the applicable
dimension table.

Plant Design System (PDS) Piping Component Data

229

Commodity Discussions
See section titled "Choosing a Branch Connection from a Branches Table" for details.
If a "1" is entered in such column, the system is to prompt for dimensions. If dimensions
are provided by the user, their values are stored in the TDB so that in subsequent
recreations of the piping system, those values and not those that might exist in a data
table are used by the system.
Data defined for these components will allow the system to determine the applicable stress
intensification factors (SIF) to be used in stress analysis of the piping system.
The thickness of the portion of piping from PCP2 of this component to the centerline of the
header is reported as "RIGID" to the Pipe Stress Analysis software, regardless of the value in
the Piping Job Specification so as not to provide a fictitious flexibility.
The empty weight of these components is neglected.

Assemblies
See Also
In-line Piping Macrocomponents (6N8C) (on page 230)
On-line Piping Macrocomponents (6P8C) (on page 230)

In-line Piping Macrocomponents (6N8C)


6N8C37,
6N8C38,
6N8C39,
6N8C40,

Air utility station (in-line) (macrocomponent)


Nitrogen utility station (in-line) (macrocomponent)
Water utility station (in-line) (macrocomponent)
Steam utility station (in-line) (macrocomponent)

On-line Piping Macrocomponents (6P8C)


6P8C14,
6P8C15,
6P8C16,
6P8C24,
6P8C64,
6P8C65,
6P8C66,
6P8C67,
6P8C68,
6P8C69,
6P8C70,
6P8C71,

230

Vent/drain
Vent/drain
Vent/drain
Vent/drain
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection

detail
detail
detail
detail
detail
detail
detail
detail
detail
detail
detail
detail

1
2
3
H
1
2
3
4
5
6
7
8

(on-line)
(on-line)
(on-line)
(on-line)
(on-line)
(on-line)
(on-line)
(on-line)
(on-line)
(on-line)
(on-line)
(on-line)

(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)
(macrocomponent)

Plant Design System (PDS) Piping Component Data

APPENDIX C

Symbols
In This Appendix
Piping Commodity Symbols ........................................................... 231
Fire and Safety Symbols ................................................................ 313
Piping Specialty Symbols .............................................................. 323
Instrument Specialty Symbols ....................................................... 333
Miscellaneous Symbols ................................................................. 349
Bio-Pharmaceutical SpecificationComponent Symbols ................ 371
Bio-Pharmaceutical Operators ...................................................... 401
Bio-Pharmaceutical Specialty Components .................................. 403
Details Assumed ............................................................................ 407
Piping and Instrument Symbol Notes ............................................ 425
Assembly Notes ............................................................................. 432

Piping Commodity Symbols


Piping Commodity Symbol Legend

Plant Design System (PDS) Piping Component Data

231

Symbols

Piping Commodity Symbol P1

232

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V1

Plant Design System (PDS) Piping Component Data

233

Symbols

Piping Commodity Symbol V2

234

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V2A

Piping Commodity Symbol V2B

Plant Design System (PDS) Piping Component Data

235

Symbols

Piping Commodity Symbol V3

236

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V4

Plant Design System (PDS) Piping Component Data

237

Symbols

Piping Commodity Symbol V6

238

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V8

Plant Design System (PDS) Piping Component Data

239

Symbols

Piping Commodity Symbol V11

240

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V12

Plant Design System (PDS) Piping Component Data

241

Symbols

Piping Commodity Symbol V13

242

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V16

Plant Design System (PDS) Piping Component Data

243

Symbols

Piping Commodity Symbol V18

244

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V19

Plant Design System (PDS) Piping Component Data

245

Symbols

Piping Commodity Symbol V26

246

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V32

Plant Design System (PDS) Piping Component Data

247

Symbols

Piping Commodity Symbol V33

248

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V34

Plant Design System (PDS) Piping Component Data

249

Symbols

Piping Commodity Symbol V38

250

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V40

Plant Design System (PDS) Piping Component Data

251

Symbols

Piping Commodity Symbol V41

252

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V42

Plant Design System (PDS) Piping Component Data

253

Symbols

Piping Commodity Symbol V51

254

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V58

Plant Design System (PDS) Piping Component Data

255

Symbols

Piping Commodity Symbol V62

256

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V72

Plant Design System (PDS) Piping Component Data

257

Symbols

Piping Commodity Symbol V81

258

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol V82

Plant Design System (PDS) Piping Component Data

259

Symbols

Piping Commodity Symbol F1A

260

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F4

Plant Design System (PDS) Piping Component Data

261

Symbols

Piping Commodity Symbol F6

262

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F8

Plant Design System (PDS) Piping Component Data

263

Symbols

Piping Commodity Symbol F10_1

264

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F10_2

Plant Design System (PDS) Piping Component Data

265

Symbols

Piping Commodity Symbol F13

266

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F14A

Plant Design System (PDS) Piping Component Data

267

Symbols

Piping Commodity Symbol F14B

268

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F17D

Plant Design System (PDS) Piping Component Data

269

Symbols

Piping Commodity Symbol F19

270

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F25

Plant Design System (PDS) Piping Component Data

271

Symbols

Piping Commodity Symbol F27

272

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F28

Plant Design System (PDS) Piping Component Data

273

Symbols

Piping Commodity Symbol F31

274

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F32

Plant Design System (PDS) Piping Component Data

275

Symbols

Piping Commodity Symbol F39

276

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F43_1

Plant Design System (PDS) Piping Component Data

277

Symbols

Piping Commodity Symbol F43_2

278

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F47

Plant Design System (PDS) Piping Component Data

279

Symbols

Piping Commodity Symbol F47A

280

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F63

Plant Design System (PDS) Piping Component Data

281

Symbols

Piping Commodity Symbol F84

282

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F101

Plant Design System (PDS) Piping Component Data

283

Symbols

Piping Commodity Symbol F114A

284

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F114B

Plant Design System (PDS) Piping Component Data

285

Symbols

Piping Commodity Symbol F114C

286

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F114D

Plant Design System (PDS) Piping Component Data

287

Symbols

Piping Commodity Symbol F122_1

288

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F122_2

Plant Design System (PDS) Piping Component Data

289

Symbols

Piping Commodity Symbol F125

290

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F127

Plant Design System (PDS) Piping Component Data

291

Symbols

Piping Commodity Symbol F128

292

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F134

Plant Design System (PDS) Piping Component Data

293

Symbols

Piping Commodity Symbol F145

294

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F147

Plant Design System (PDS) Piping Component Data

295

Symbols

Piping Commodity Symbol F150

296

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F152

Plant Design System (PDS) Piping Component Data

297

Symbols

Piping Commodity Symbol F154

298

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F160

Plant Design System (PDS) Piping Component Data

299

Symbols

Piping Commodity Symbol F163

300

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F170

Plant Design System (PDS) Piping Component Data

301

Symbols

Piping Commodity Symbol F172

302

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F173

Plant Design System (PDS) Piping Component Data

303

Symbols

Piping Commodity Symbol F176

304

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F177

Plant Design System (PDS) Piping Component Data

305

Symbols

Piping Commodity Symbol F180F

306

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F178

Plant Design System (PDS) Piping Component Data

307

Symbols

Piping Commodity Symbol F179

308

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F180

Plant Design System (PDS) Piping Component Data

309

Symbols

Piping Commodity Symbol F182

310

Plant Design System (PDS) Piping Component Data

Symbols

Piping Commodity Symbol F184

Plant Design System (PDS) Piping Component Data

311

Symbols

Piping Commodity Symbol F188

312

Plant Design System (PDS) Piping Component Data

Symbols

Fire and Safety Symbols


Fire and Safety Symbol FS1A

Fire and Safety Symbol FS2B

Plant Design System (PDS) Piping Component Data

313

Symbols

Fire and Safety Symbol FS10A

Fire and Safety Symbol FS10B

314

Plant Design System (PDS) Piping Component Data

Symbols

Fire and Safety Symbol FS11A

Fire and Safety Symbol FS11B

Plant Design System (PDS) Piping Component Data

315

Symbols

Fire and Safety Symbol FS13A

Fire and Safety Symbol FS13B

316

Plant Design System (PDS) Piping Component Data

Symbols

Fire and Safety Symbol FS24A

Fire and Safety Symbol FS26A

Plant Design System (PDS) Piping Component Data

317

Symbols

Fire and Safety Symbol FS26B

Fire and Safety Symbol FS30A

318

Plant Design System (PDS) Piping Component Data

Symbols

Fire and Safety Symbol FS38A

Fire and Safety Symbol FS39A

Plant Design System (PDS) Piping Component Data

319

Symbols

Fire and Safety Symbol FS60A

Fire and Safety Symbol FS66A338

320

Plant Design System (PDS) Piping Component Data

Symbols

Fire and Safety Symbol T-FS1A

Fire and Safety Symbol T-FS2B

Plant Design System (PDS) Piping Component Data

321

Symbols

Fire and Safety Symbol T-FS10A

Fire and Safety Symbol T-FS11A

322

Plant Design System (PDS) Piping Component Data

Symbols

Fire and Safety Symbol T-FS13A

Piping Specialty Symbols


Piping Specialty Symbol S1AC

Plant Design System (PDS) Piping Component Data

323

Symbols

Piping Specialty Symbol S1BZ

Piping Specialty Symbol S3AZ

324

Plant Design System (PDS) Piping Component Data

Symbols

Piping Specialty Symbol S4AC

Piping Specialty Symbol S5AZ

Plant Design System (PDS) Piping Component Data

325

Symbols

Piping Specialty Symbol S7AZ

Piping Specialty Symbol S11BZ

326

Plant Design System (PDS) Piping Component Data

Symbols

Piping Specialty Symbol S13AZ

Piping Specialty Symbol S28AZ

Plant Design System (PDS) Piping Component Data

327

Symbols

Piping Specialty Symbol S28BZ

Piping Specialty Symbol S32BC

328

Plant Design System (PDS) Piping Component Data

Symbols

Piping Specialty Symbol S36AZ

Piping Specialty Symbol S49AC

Plant Design System (PDS) Piping Component Data

329

Symbols

Piping Specialty Symbol S51AC

Piping Specialty Symbol S53AC

330

Plant Design System (PDS) Piping Component Data

Symbols

Piping Specialty Symbol S64BC

Piping Specialty Symbol S70AC

Plant Design System (PDS) Piping Component Data

331

Symbols

Piping Specialty Symbol S70BC

Piping Specialty Symbol S78AC

332

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbols


Instrument Specialty Symbol I3AZ

Instrument Specialty Symbol I5AZ

Plant Design System (PDS) Piping Component Data

333

Symbols

Instrument Specialty Symbol I6AZ

Instrument Specialty Symbol I7AZ

334

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I8AZ

Instrument Specialty Symbol I11AZ

Plant Design System (PDS) Piping Component Data

335

Symbols

Instrument Specialty Symbol I12AZ

Instrument Specialty Symbol I13AZ

336

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I14AZ

Instrument Specialty Symbol I15AZ

Plant Design System (PDS) Piping Component Data

337

Symbols

Instrument Specialty Symbol I16AZ

Instrument Specialty Symbol I17AZ

338

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I18AZ

Instrument Specialty Symbol I20AZ

Plant Design System (PDS) Piping Component Data

339

Symbols

Instrument Specialty Symbol I30AZ

Instrument Specialty Symbol I106BZ

340

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I109BZ

Instrument Specialty Symbol I118BZ

Plant Design System (PDS) Piping Component Data

341

Symbols

Instrument Specialty Symbol I120AZ

Instrument Specialty Symbol I201AZ

342

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I201BZ

Instrument Specialty Symbol I201CZ

Plant Design System (PDS) Piping Component Data

343

Symbols

Instrument Specialty Symbol I209AZ

Instrument Specialty Symbol I213AZ

344

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I216AZ

Instrument Specialty Symbol I219AZ

Plant Design System (PDS) Piping Component Data

345

Symbols

Instrument Specialty Symbol I237AZ

Instrument Specialty Symbol I253AZ

346

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I301AZ

Instrument Specialty Symbol I324CZ

Plant Design System (PDS) Piping Component Data

347

Symbols

Instrument Specialty Symbol I324DZ

Instrument Specialty Symbol I324EZ

348

Plant Design System (PDS) Piping Component Data

Symbols

Instrument Specialty Symbol I324FZ

Miscellaneous Symbols
Miscellaneous Symbol OP3

Plant Design System (PDS) Piping Component Data

349

Symbols

Miscellaneous Symbol OP4

Miscellaneous Symbol OP5

350

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP9373

Miscellaneous Symbol OP_251

Plant Design System (PDS) Piping Component Data

351

Symbols

Miscellaneous Symbol OP_271

Miscellaneous Symbol OP_291

352

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_292

Miscellaneous Symbol OP_311

Plant Design System (PDS) Piping Component Data

353

Symbols

Miscellaneous Symbol OP_331

Miscellaneous Symbol OP_332

354

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_333

Miscellaneous Symbol OP_334

Plant Design System (PDS) Piping Component Data

355

Symbols

Miscellaneous Symbol OP_351

Miscellaneous Symbol OP_391

356

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_401

Miscellaneous Symbol OP_411

Plant Design System (PDS) Piping Component Data

357

Symbols

Miscellaneous Symbol OP_412

Miscellaneous Symbol OP_413

358

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_451

Miscellaneous Symbol OP_452

Plant Design System (PDS) Piping Component Data

359

Symbols

Miscellaneous Symbol OP_453

Miscellaneous Symbol OP_491

360

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_492

Miscellaneous Symbol OP_493

Plant Design System (PDS) Piping Component Data

361

Symbols

Miscellaneous Symbol OP_494

Miscellaneous Symbol OP_571

362

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_572

Miscellaneous Symbol OP_573

Plant Design System (PDS) Piping Component Data

363

Symbols

Miscellaneous Symbol OP_574

Miscellaneous Symbol OP_711

364

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_731

Miscellaneous Symbol OP_811

Plant Design System (PDS) Piping Component Data

365

Symbols

Miscellaneous Symbol OP_851

Miscellaneous Symbol OP_852

366

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol OP_853

Miscellaneous Symbol OP_854

Plant Design System (PDS) Piping Component Data

367

Symbols

Miscellaneous Symbol A1003

Miscellaneous Symbol A1005

368

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol A1251

Miscellaneous Symbol A1331

Plant Design System (PDS) Piping Component Data

369

Symbols

Miscellaneous Symbol A1332

Miscellaneous Symbol S2003

370

Plant Design System (PDS) Piping Component Data

Symbols

Miscellaneous Symbol S3003

Bio-Pharmaceutical SpecificationComponent
Symbols
Bio-Pharm Specification Component Symbol FERR

Plant Design System (PDS) Piping Component Data

371

Symbols

Bio-Pharm Specification Component Symbol FERS

Bio-Pharm Specification Component Symbol CAPT

372

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol CAPSE

Bio-Pharm Specification Component Symbol HA

Plant Design System (PDS) Piping Component Data

373

Symbols

Bio-Pharm Specification Component Symbol FA

Bio-Pharm Specification Component Symbol FAS

374

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol MA

Bio-Pharm Specification Component Symbol MAR

Plant Design System (PDS) Piping Component Data

375

Symbols

Bio-Pharm Specification Component Symbol B90T

376

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol B90TC

Plant Design System (PDS) Piping Component Data

377

Symbols

Bio-Pharm Specification Component Symbol B90C

378

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol B45T

Bio-Pharm Specification Component Symbol B45TC

Plant Design System (PDS) Piping Component Data

379

Symbols

Bio-Pharm Specification Component Symbol B45C

Bio-Pharm Specification Component Symbol R180R

380

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol R180C

Bio-Pharm Specification Component Symbol TT

Plant Design System (PDS) Piping Component Data

381

Symbols

Bio-Pharm Specification Component Symbol TTRB

382

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol TCB

Plant Design System (PDS) Piping Component Data

383

Symbols

Bio-Pharm Specification Component Symbol TRCB

384

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol TSCB

Bio-Pharm Specification Component Symbol TRSCB

Plant Design System (PDS) Piping Component Data

385

Symbols

Bio-Pharm Specification Component Symbol TICB

Bio-Pharm Specification Component Symbol TSCR

386

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol XT

Plant Design System (PDS) Piping Component Data

387

Symbols

Bio-Pharm Specification Component Symbol XTRB

388

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol XC

Plant Design System (PDS) Piping Component Data

389

Symbols

Bio-Pharm Specification Component Symbol TC

390

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol TCR

Plant Design System (PDS) Piping Component Data

391

Symbols

Bio-Pharm Specification Component Symbol TCSB

Bio-Pharm Specification Component Symbol TCRSB

392

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol TCI

Bio-Pharm Specification Component Symbol RCP

Plant Design System (PDS) Piping Component Data

393

Symbols

Bio-Pharm Specification Component Symbol RCCL

Bio-Pharm Specification Component Symbol RCC

394

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol REP

Bio-Pharm Specification Component Symbol RECL

Plant Design System (PDS) Piping Component Data

395

Symbols

Bio-Pharm Specification Component Symbol REC

Bio-Pharm Specification Component Symbol CHA

396

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol C2HD

Bio-Pharm Specification Component Symbol C3HD

Bio-Pharm Specification Component Symbol CPAN

Plant Design System (PDS) Piping Component Data

397

Symbols

Bio-Pharm Specification Component Symbol CPHB

Bio-Pharm Specification Component Symbol CA

Bio-Pharm Specification Component Symbol CSJ

398

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specification Component Symbol CHD

Bio-Pharm Specification Component Symbol VS2D


The symbol below represents a symmetrical valve where DIMENSION_1 is equal to
DIMENSION_2.

Plant Design System (PDS) Piping Component Data

399

Symbols
The symbol below shows a non-symmetrical valve where DIMENSION_1 is not equal to
DIMENSION_2. The distance between the Center (CP0) and Connect Point 2 (CP2) is
represented by DIM_2/2.

400

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharmaceutical Operators
Bio-Pharm Operator Symbol SOP_3

Plant Design System (PDS) Piping Component Data

401

Symbols

Bio-Pharm Operator Symbol SOP_42

402

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharmaceutical Specialty Components


Bio-Pharm Specialty Component Symbol R180B

Plant Design System (PDS) Piping Component Data

403

Symbols

Bio-Pharm Specialty Component Symbol R180S

Bio-Pharm Specialty Component Symbol VSDTP

404

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specialty Component Symbol VSDTC

Bio-Pharm Specialty Component Symbol VSCCB

Bio-Pharm Specialty Component Symbol VSCCBU425

Plant Design System (PDS) Piping Component Data

405

Symbols

Bio-Pharm Specialty Component Symbol VS3WD

406

Plant Design System (PDS) Piping Component Data

Symbols

Bio-Pharm Specialty Component Symbol VS4WD

Details Assumed
Detail V1

Plant Design System (PDS) Piping Component Data

407

Symbols

Detail V2

Detail V3

408

Plant Design System (PDS) Piping Component Data

Symbols

Detail V4

Detail V5

Plant Design System (PDS) Piping Component Data

409

Symbols

Detail V7

Detail V8

410

Plant Design System (PDS) Piping Component Data

Symbols

Detail H1

Detail H2

Plant Design System (PDS) Piping Component Data

411

Symbols

Detail H3

Detail H4

412

Plant Design System (PDS) Piping Component Data

Symbols

Detail F1

Detail F2

Plant Design System (PDS) Piping Component Data

413

Symbols

Detail F4

Detail F7

414

Plant Design System (PDS) Piping Component Data

Symbols

Detail F8

Detail P1

Plant Design System (PDS) Piping Component Data

415

Symbols

Detail P2

Detail P3

416

Plant Design System (PDS) Piping Component Data

Symbols

Detail P4

Detail P5

Plant Design System (PDS) Piping Component Data

417

Symbols

Detail P7

Detail P8

418

Plant Design System (PDS) Piping Component Data

Symbols

Detail P9

Detail T1

Plant Design System (PDS) Piping Component Data

419

Symbols

Detail T

Detail T4

420

Plant Design System (PDS) Piping Component Data

Symbols

Detail L1

Detail L2

Plant Design System (PDS) Piping Component Data

421

Symbols

Detail L4

422

Plant Design System (PDS) Piping Component Data

Symbols

Detail L7

Plant Design System (PDS) Piping Component Data

423

Symbols

Detail L8

424

Plant Design System (PDS) Piping Component Data

Symbols

Piping and Instrument Symbol Notes


1. Surface area, empty weight and water weight will be read from the applicable data source.
The attribute values read will be stored in the Piping TDB.
2. Unit surface area, unit empty weight and unit water weight will be read from the applicable
tables. The attribute values read will be stored in the Piping TDB.
3. Wall thickness will be read, alothough not by the Eden symbol, from the Piping Job
Specification or Instrument TDB. The attribute value read will be stored in the Piping TDB.
4. Simplified and detailed definitions are identical for this component.
5. The surface defining the end of a component will be drawn per the following conventions:
For grooved and female face flanged ends: a distance "S" towards the origin from the
actual outermost surface of the component. In other words, the end will be terminated at the
bottom of the groove.
For all other bolted ends: at the actual outermost surface of the component.
For all male ends: at the actual outermost surface of the component.
6.

7.
8.
9.
10.

For all female ends: a distance "Q" from the actual outermost surface of the component.
The origin of the component will be located mid-way between PCP1 and PCP2 for two
connect point components and in the center of the component for single connect point
components.
It is not required to retrieve values for surface area, empty weight and water weight for this
component.
The origin of the component will be located mid-way between PCP1 and the outermost most
surface of the component at the end opposite PCP1.
This will be a vertical cylinder whose nominal pipe diameter will be equal to the nominal pipe
diameter of the valve.
This parameter will have a value equal to the applicable of "A", "E" or "P2" times the factor
indicated below:
Nominal Pipe Diameter Range
Factor
2 and smaller
0.50
2.01-10
0.55
10.01 and larger
0.60

11. The combined height of these cones will equal the nominal pipe diameter of the valve.
The value for the base of each of the cones will equal the applicable of "A" or "E" times the
factor indicated below:
Nominal Pipe Diameter Range
Factor
2 and smaller
0.40
2.01-10
0.45
10.01 and larger
0.50
12.
13.
14.
15.
16.

The value of this parameter will equal the nominal pipe diameter of the valve divided by 2.
The length of this cylinder will be a minimum.
Four equally spaced concentric rings will be provided.
This parameter will equal 1.2 times the value of dimension "O".
This parameter will have a value equal to the applicable parameter "E" times the factor
indicated below:
Nominal Pipe Diameter Range
Factor
0.5 and smaller
0.90

Plant Design System (PDS) Piping Component Data

425

Symbols
0.51-2.00
2.01 and larger

0.75
0.60

17. This parameter will have a value equal to the applicable parameter "E" times the factor
indicated below:
Nominal Pipe Diameter Range
Factor
0.5 and smaller
0.25
0.51-2.00
0.20
2.01 and larger
0.12
18. For components all whose ends are either bolted or female end types and that require a
dimension from the male termination type generic table, the system will use the table
corresponding to table suffix "5".
19. This parameter will have a value equal to the applicable parameter "L" times the factor
indicated below:
Nominal Pipe Diameter Range
Factor
0.5 and smaller
0.20
0.51-2.00
0.12
2.01 and larger
0.10
20. The reinforcement will be represented as a 360 degree cylinder concentric with the branch
pipe.
21. The location of PCP2 will be determined by the system so that the point in the OD of the end
cross-section of the branch pipe that is furthest removed from the header centerline will be
located as follows:
For model codes RPAD and RWELD: on the outside surface of the header pipe.
For model codes RPAD2 and RWELD2: on the inside surface of the header pipe.
22. Values for weld length and OD will depend upon the system of units of measure used, as
defined by the specific model code used, as follows:
Model Code
Weld Length
Weld OD
BWELD
0.0625"
P + 0.0625"
BWELD1
By Others
By Others
BWELD2
By Others
By Others
23. Parameter "P4" will define the space occupied by the valve disk in the open position. Its sign
will be positive (+) if in the direction of the secondary axis of the orientation tee or negative (-)
if opposite to it.
24. You define the dimensional or orientation parameters listed below during the design session,
following the system prompts. The values so entered will be used during model
reconstruction. Labels may be prepared to display this value on the iso and/or in the iso
materials listing.
Symbol Name
Tutorial Name
Parameter
FS1A
FS1A
D1
FS2B
FS2B
D5
FS10A
FS10A
D3, D9
FS11A
FS11A
D3, D9
FS13A
FS13A
D3, D9
25. For SN=FS2B, the parallelepiped defined by parameters "D8", "D9" and "D10" will rotate,
together with the nozzle, by the specified angle D14, with due regards to sign.
26. This symbol applies to cubical components that have one of their axis oriented along the
direction of the primary axis of the coordinate system for the component. The origin of the
component will be located at the intersection of its diagonals. It will be possible to place
components to which this symbol applies either by their origin or by PCP1. The tertiary axis of

426

Plant Design System (PDS) Piping Component Data

Symbols

27.
28.

29.

30.
31.
32.
33.

34.

the component is defined as that axis which follows the direction of the thumb of the right hand
when the other fingers of the right hand are curled in the direction following the path from the
positive end of the primary axis of the component to the positive end of the secondary axis of
the component. The output parameters which are specific to this symbol are defined as
follows:
Output D1 - defines the vectorial distance from the origin of the component to PCP1 along the
direction of the primary axis of the component. Its sign will be positive if the vector is in the
direction of the primary axis of the component and negative if it is opposite to the direction of
the primary axis of the component.
Output D2 - defines the vectorial distance from the origin of the component to PCP1 along the
direction of the secondary axis of the component. Its sign will be positive if the vector is in the
direction of the secondary axis of the component and negative if it is opposite to the direction
of the secondary axis of the component.
Output D3 - defines the vectorial distance from the origin of the component to PCP1 along the
direction of the tertiary axis of the component. Its sign will be positive if the vector is in the
direction of the tertiary axis of the component and negative if it is opposite to the direction of
the tertiary axis of the component.
Output D4 - defines the length of the component along the direction of the primary axis of the
component. Its sign will always be positive.
Output D5 - defines the length of the component along the direction of the secondary axis of
the component. Its sign will always be positive.
Output D6 - defines the dimension of the component along the direction of the tertiary axis of
the component. Its sign will always be positive.
The nominal pipe diameter of PCP1 refers to the header size.
The value for angle B and/or for "angle" will be intrinsic to the component being placed, unless
it is stated in Appendix B that it is to be determined by the system from data contained in the
design file.
You will first identify the PCP of the elbow that will determine the centerline direction of the
elbolet, as defined by the primary axis of the orientation tee of the elbow PCP. When
placement of an elbolet is involved, the system will always place PCP2 of the elbolet pointing
away from the elbow, regarless of the direction in which the orientation tee points. The
system will then place a temporary PCP at the intersection of the primary axis of the
orientation tee with the outside of the elbow. This temporary PCP will then be moved inside
the elbow by a fixed amount to ensure that the connection between the elbolet and the elbow
will not "leak". The "moved" PCP will become PCP1 for the elbolet. The system will then
place PCP2 for the elbolet using the "M" dimension from the data table.
Dimension "N" will be equal to the branch (RCP) outside diameter "P" plus "2K".
The value for parameter "M" will be provided in the "Mod" column of the Piping Job
Specification. It will not be stored in any data table.
This dimension will be equal to "1.5P".
The value of "N" may be positive or negative, depending upon the type of end being defined.
If the value of "N" is <=0, the system will not draw a cylinder to represent the female end
socket.
The origin of the section describing this component will be located at the intersection of the
plane containing the axis of flow for the component with the planes at the ends of the
component, as follows:
For bolted ends: the plane passing through the back of the bolted end.
For male and female ends: the plane passing through the corresponding connect point.

Plant Design System (PDS) Piping Component Data

427

Symbols
35. The origin of the section describing this component will be located at the intersection of the
plane containing the axis of flow for the component with the planes at the ends of the
component, as follows:
For bolted ends: not applicable.
For male or female ends: the plane passing through a point located inward from the
corresponding connect point "end distance" "K" or "L", if applicable.
36. For pipe bends, the radius of the torous for this component will be the nominal pipe diameter
of the component times the value included in the "Mod" column of the Piping Job
Specification.
For all other applicable components, the radius of the torous will be determined from the
equations listed below:
For bolted ends: [A - R] [tan Y/2]
For male ends: [E - K] [tan Y/2]
For female ends: [E - K] [tan Y/2]

37.
38.
39.
40.

41.
42.

For male-female ends: [E - K] [tan Y/2]


where, Y refers to the angle; A, E, R and K are as defined in the applicable symbol.
The origin of the radius will be positioned at the location defined in the symbol.
Unions are only required for model codes E45U, E90U, TUOR and TUOB.
The number of taps will be provided in the "Mod" column of the Piping Job Specification. The
same data table will apply regardless of the number of taps involved.
Dimensions "K" and "L" are required to calculate factors used in stress analysis of the piping
system.
If half of "P" for PCP3 is greater than "F", locate the end of the component in the vicinity of
PCP2 a distance equal to "0.7P" from the origin of the component and locate PCP2 a distance
"F" from the origin.
Parameter "K" will be no less than 0.25 inch and no more than the lesser of 0.5 inch or 90% of
dimension "O".
Parameter "M" will equal the nominal pipe diameter times the factor indicated below:
Nominal Pipe Diameter Range d
Factor
3 and smaller
1.25
3.01-10
0.55
10.01 and larger
0.30

43. Values have been provided for parameter "O" per the following formula:
T= T-API-590 - CA-API-590 + CA + FA, rounded to the next 1/16th inch
where,
T-API-590 - is the applicable blank thickness defined in API-590.
CA-API-590 - is the applicable blank corrosion allowance defined in API-590.
CA - is 0.125 inch for geometry standards API-590Z1 or AITKEN Z1; 0.25 inch for geometry
standards API-590Z2 or AITKEN Z2.
FA - is 0.125 inch if RFTBE is involved; 0 inch for all other ends.
44. Provide a cylinder with the following dimensions:
Diameter "P", where "P" is the outside diameter from the applicable generic table.
Length having a value equal to the nominal pipe diameter of the applicable end times the
factor indicated below:

428

Plant Design System (PDS) Piping Component Data

Symbols
Nominal Pipe Diameter Range
1 and smaller
1.01-3.50
3.51 and larger

Factor
2.00
1.00
0.50

45. The drain for the component, PCP3, will be located in the plane defined by the primary and
secondary axis of the orientation tee.
46. This parameter will equal the nominal pipe diameter times the factor indicated below:
Nominal Pipe Diameter Range
Factor
3 and smaller
1.25
3.01-10
0.55
10.01 and larger
0.30
47. Model codes and symbols ending in the letter "C", for example S1AC, may be used to
represent piping commodity components. Since the EDEN software does not recognize
"generic" components for piping commodity components, however, the following limitations
apply:
Model codes S1AC, S3AC and S4AC must be defined to have no offset; for example, for
model S1AC, parameters P4 and P5 must be defined to be zero.
For model code S51AC, parameter P7 must be zero.
Model code S64BC does not work at all.
The above limitations do not apply to piping specialty components.
48. This symbol will be used to represent off-line instruments by means of a cylinder. The
following comments will apply:
The applicability of this representation will be defined by you, making the proper menu
selection at placement time. It will be remembered by the system during reconstruction of
the model.
Several identical model codes have been provided (I301iT or I301iS, where i=A-J) to allow
definition of up to 2000 instruments of the same AABBCC code.
No access to a data table will be required when this representation applies. If values are
not entered for P2 and P3, they will be defaulted to "minimum" and "6 inches" respectively.
49. Output P1 defines the total number of connect points applicable to the component. If the
number entered in this field is less than the number of connect points shown pictorially in the
sketch for the applicable symbol, only the number of connect points entered for this parameter
will apply.
50. Output P1 defines the total number of connect points applicable to the component. The
number entered for this parameter must agree with the number of connect points shown
pictorially in the sketch for the applicable symbol.
51. The following note applies to operators with chainwheels:
The diameter of the chainwheel will be assumed to be equal to that of the corresponding
handwheel.
The value for the chainwheel height (CW Height) will be determined by the software as a
function of the corresponding handhweel diameter (HW Diam), as follows:
HW Diam
CW Height
=<6.000
(0.33333)(HW Diam)
>6.000, =<42.000
3.0
>42.000
(0.07143)(HW Diam)
52. During reconstruction of the model, the system will automatically place the operator with the
dimensions and in the orientation defined by you during initial placement. For piping

Plant Design System (PDS) Piping Component Data

429

Symbols

53.

54.
55.

56.
57.

58.

components, if you added an appurtenance, this is also remembered by the reconstruction


software.
For components that have operators or actuators, the secondary axis of the orientation tee
used in placing the component will define the direction of the operator. The primary direction
of the operator or actuator will be oriented by the system in the direction of the secondary axis
of the orientation tee used in placing the component. The secondry direction of the operator
or actuator will be oriented by the system in the direction of the primary axis of the orientation
tee used in placing the component. No auxiliary orientation tee will be available to change
the orientation of the operator or actuator. The resulting operator orientation will be defined
on the isometric drawing.
However, the orientation of an operator or actuator depends upon how both the component
and the operator were defined. If either of them was defined to have the operator oriented
with a secondary orientation tee (see note 71), such secondary orientation tee will apply and
will behave as defined in note 71.
Those parameters shown on the sketch with a + sign may be either positive or negative. All
other parameters must always have positive values.
Commodity descriptions for chain operators, floor stands and extension stems will be derived
from commodity codes CHAIN_*, FSTAND_* and XSTEM_*. Refer to documents explaining
the generation of isometric drawings and materials reports for details.
The value of this parameter will equal the nominal pipe diameter of the valve.
For components that have operators or actuators, the orientation tee used in placing the
component involved will be used to orient the operator or actuator. Upon placement of the
component, the system will place an auxiliary orientation tee at the origin of the component to
allow the orientation of the operator or actuator. As a default, the primary axis of the auxiliary
orientation tee will be oriented by the system in the direction of the secondary axis of the
primary orientation tee (even if the operator is at an angle) and will define the direction of the
operator or actuator. As a default, the secondary axis of the auxiliary orientation tee will point
in the direction of the primary axis of the primary orientation tee. You will then be able to
orient the operator or actuator by manipulating the orientation of either the primary or the
secondary axis of the auxiliary orientation tee. The resulting operator orientation will be
defined on the isometric drawing.
However, the orientation of an operator or actuator depends upon how both the component
and the operator were defined. If either of them was defined to have the operator oriented
with a secondary orientation tee, such secondary orientation tee will apply and will behave as
defined in note 71.
The system will record in the TDB DMRS database the value of the angular parameter defined
below. This angle will be used by the Isogen Interface Software to define the primary
orientation of the operator on the iso.
Symbol Name
Parameter
OP5
Y3
OP_311
Y4
OP_351
Y4
OP_412
Y5
OP_492
Y5
OP_572
Y5
OP_574
Y5
OP_852
Y5
OP_854
Y5

59. The optional capability will be provided to define, for stress analysis purposes, the weight of
the operator and the location of the center of gravity of the operator weight. The location of
the center of gravity is defined by parameters "Y1", "Y2" and "Y3". The weight of the

430

Plant Design System (PDS) Piping Component Data

Symbols
component itself, exclusive of the operator, will still be defined as part of the component's
table. The operator data will be retrieved as part of the data transfer to the pipe stress
analysis program taking into full consideration the orientation and rotation made of the
operator at placement time.
60. If there is no stem extension above the top of the gear operator, define the parameter
identified below as "0.0". Never define such
parameter as "-".
Symbol Name
Parameter
OP_291
Y10
OP_292
Y13
OP_311
Y10
OP_331
Y11
OP_332
Y13
OP_333
Y12
OP_334
Y12
OP_351
Y12

61.

62.

63.

64.

For data tables that are prepared without this parameter, the EDEN symbol will assume that
no stem extension applies.
The dimensions for gear operators shown on data tables were obtained in the following
manner: from the fully open valve stem dimension stated in the catalog we subtracted the
valve nominal pipe diameter to account for the stem free travel. We then added the flange
adaptor height, as advised by the Manufacturer, and the height of the gear operator, from
catalog dimensions.
The angle that the secondary axis of the auxiliary orientation tee makes in its final position
with its default position is required for the purchase of the valve and must be supplied by the
system to the materials control function.
For this operator, the center of gravity of the valve operator will always be located along the
operator stem. The values of "Y2" and "Y3" will always be "-" in the corresponding operator
data table.
The dimensional or orientation parameters listed below will be defined by you from the design
session, upon prompting by the system. The values so entered will be used during model
reconstruction. Labels may be prepared to display this value on the iso and/or in the iso
materials listing.
Symbol Name
Tutorial Name
Parameter(s)
OP_333
ZO333D
Y11
OP_334
ZO334D
Y11
OP_401
ZO401D
Y6

65. During placement of this operator, the tutorial listed below will be displayed for you to select
the orientation of the handwheel.
Symbol Name
Tutorial Name
OP_331
ZO331O
OP_332
ZO331O
OP_333
ZO331O
OP_334
ZO331O
OP_351
ZO331O
66. Parameter "Y1" will be the operator type and will be only listed in the applicable actuator data
table.
67. The optional capability will be provided to define, for stress analysis purposes, the weight of
the actuator and the location of the center of gravity of the actuator weight. The location of
the center of gravity is defined by parameters "Y2", "Y3" and "Y4". The weight of the

Plant Design System (PDS) Piping Component Data

431

Symbols
component itself, exclusive of the actuator, will still be defined as part of the component's
table. The actuator data will be retrieved as part of the data transfer to the pipe stress
analysis program taking into full consideration the orientation and rotation made of the
actuator at placement time.
68. For this actuator, the center of gravity of the valve actuator will always be located along the
actuator stem. The values of "Y3" and "Y4" will always be "-" in the corresponding actuator
data table.

Assembly Notes
1. For a vent/drain connection off a pipe run, the system will place the appropriate branch
reinforcement component on the basis of data in the applicable branch reinforcement table.
For a vent/drain connection off equipment item, a piping component or an instrument
component, you must select the proper component to which the vent drain assembly will be
connected. This may require defining a nozzle in an item of equipment or placing a tap on a
piping component.
2. The characteristics of this branch nipple and of the flange mating the vent/drain valve, if
applicable, will be as follows:
If the CP of the vent/drain valve that is nearest the pipe run has an end preparation type in the
range from 10 through 81, as defined by codelist set CL330, the following will apply:
If the pipe run is not insulated, the following applies:
If the end preparation of the CP of the branch component that applies to the assembly
is in the range from 10 through 81, as defined by codelist set CL330, no branch nipple
nor vent/drain valve mating flange will be required. The vent/drain valve will be
bolted directly to the flange of the branch.
If the end preparation of the CP of the branch component that applies to the assembly
is 301, as defined by codelist set CL330, no branch nipple will be required. The
flange that mates the vent/drain valve will be chosen to have a RCP with end
preparation 301 and will be connected directly to the assembly end of the branch
component.
If the end preparation of the CP of the branch component that applies to the assembly
is 421 or 441, as defined by codelist set CL330, a 4 inch long branch nipple will be
required. If end preparation 421 is involved, applicable AABBCC and option codes
for the branch nipple will be 6Q3C88 and 728 respectively. If end preparation 441 is
involved, applicable AABBCC and option codes for the branch nipple will be 6Q3C88
and 727 respectively. The flange that mates the vent/drain valve will be chosen to
have a RCP with end preparation to suit that of the assembly end of the branch
component (421 or 441) and will be connected directly to the assembly end of the
branch nipple.
If the end preparation of the CP of the branch component that applies to the assembly
is other than defined above, an error message will be returned by the system when
use of this assembly is attempted.
If the pipe run is insulated, the following applies:
If the end preparation of the CP of the branch component that applies to the assembly
is in the range from 10 through 81, as defined by codelist set CL330, no branch nipple
nor vent/drain valve mating flange will be required. The vent/drain valve will be
bolted directly to the flange of the branch.

432

Plant Design System (PDS) Piping Component Data

Symbols

If the end preparation of the CP of the branch component that applies to the assembly
is 301, 421 or 441, as defined by codelist set CL330, a branch nipple will be provided
with nominal length defined by the following equation:
L= 1 + P/2 + T + W_i - B - N
where, L - is the nominal length required for the branch nipple
1 - is one inch
P/2 - is half the outside pipe diameter as derived from table MAL_Term_TS for the
pipe run.
T - is the insulation thickness of the pipe run as derived from the TDB

W_i - is the nut allowance as derived from the applicable of the tables described
below
STUD_Rat_TS, if the RDB option that involves CP termination for bolt length calculations
is not active;

OR
STUD_Term_Rat_TS, if the RDB option that involves CP termination for bolt length
calculations is active that applies to the bolts used by the vent/drain valve.
B - is the offset of assembly end of the branch component from the centerline of the pipe
run, derived from the applicable branch component dimension table.
N - is the distance from the back of the flange to CP2 in the flange, as defined in table
MC_GS_Term(G)_Rat(G)_Term(R)_Rat(R)_A that applies to the vent/drain valve.
The nominal length of the branch nipple determined from the above equation will be
rounded to the next full inch length but will be no less than 4 inches long. The end
preparation(s) of the branch nipple will be chosen by the system to suit the end
preparation types of the branch component. If end preparation 301 is involved,
applicable AABBCC and option codes for the branch nipple will be PIPING and 1
respectively. If end preparation 421 is involved, applicable AABBCC and option codes
for the branch nipple will be 6Q3C88 and 728 respectively. If end preparation 441 is
involved, applicable AABBCC and option codes for the branch nipple will be 6Q3C88 and
727 respectively.
The flange that mates the vent/drain valve will be chosen by the system to have a RCP
with end preparation to suit that of the assembly end of the branch component (301, 421
or 441) and will be connected to the branch nipple.
If the end preparation of the CP of the branch component that applies to the assembly is
other than defined above, an error message will be returned by the system when use of
this assembly is attempted.
If the CP of the vent/drain valve which is nearest the pipe run has end preparation type of
either 421 or 441, as defined by codelist set CL330, a branch nipple will be required. The
branch nipple length will be 1 inch longer than the insulation thickness of the pipe run rounded
to the next full inch length but no less than 4 inches long. The end preparations of the branch
nipple will be chosen by the system to suit the end preparation types of the branch component
and of the vent/drain valve. If end preparation 421 is involved, applicable AABBCC and
option codes for the branch nipple will be 6Q3C88 and 728 respectively. If end preparation
441 is involved, applicable AABBCC and option codes for the branch nipple will be 6Q3C88
and 727 respectively.
No flange will be required to mate the vent/drain valve.

Plant Design System (PDS) Piping Component Data

433

Symbols
If the CP of the vent/drain valve which is nearest the pipe run has end preparation type other
than in the range from 10-81 or of either 421 or 441, as defined by codelist set CL330, an error
message will be returned by the system when use of this assembly is attempted.
3. If the mating CPs of the valves in the vent/drain assembly have an end preparation other than
421, an error message will be returned by the system when use of this assembly is attempted.
4. If any of the CPs of the valve in the vent/drain assembly have an end preparation other than
401 or if the pipe is insulated beyond 4 inches thickness, an error message will be returned by
the system when use of this assembly is attempted.

434

Plant Design System (PDS) Piping Component Data

APPENDIX D

Commodity Code Descriptions


In This Appendix
Commodity Code Matrix ................................................................ 435
Flanged and Miscellaneous Fittings .............................................. 436
Completing Materials ..................................................................... 441
Fire and Safety Components ......................................................... 442
Steam Specialties .......................................................................... 443
Flanges .......................................................................................... 446
Flanged Fittings ............................................................................. 453
Strainer Specialties ........................................................................ 459
Instrument Specialties ................................................................... 465
Pipe Supports ................................................................................ 475
Labor Codes .................................................................................. 488
Miscellaneous Wetted Fittings ....................................................... 496
Miscellaneous Non-Wetted Fittings ............................................... 497
Tubing and Hose ........................................................................... 499
Pipe ................................................................................................ 504
Socket Fittings ............................................................................... 516
Tubing Fittings ............................................................................... 518
Socketwelded Fittings .................................................................... 524
Threaded Fittings ........................................................................... 527
Underground Fittings ..................................................................... 532
Valves ............................................................................................ 535
Welded Fittings .............................................................................. 551
Gaskets .......................................................................................... 559
Bolting ............................................................................................ 566

Commodity Code Matrix


The commodity code matrix used to develop the commodity codes in the piping materials classes
is shown below. The first letter of the commodity code identifies the basic type of component, such
as a valve or flange. The remaining characters provide a detailed description of the component.
The first character designations are:
B

Flanged and Miscellaneous Fittings (on page 436)

Completing Materials (on page 441)

Fire and Safety Components (on page 442)

Steam Specialties (on page 443)

Flanges (on page 446)

Flanged Fittings (on page 453)

Strainer Specialties (on page 459)

Instrument Specialties (on page 465)

Plant Design System (PDS) Piping Component Data

435

Commodity Code Descriptions


J

Pipe Supports (on page 475)

Labor Codes (on page 488)

Miscellaneous Wetted Fittings (on page 496)

Miscellaneous Non-Wetted Fittings (on page 497)

Tubing and Hose (on page 499)

Pipe (on page 504)

Socket Fittings (on page 516)

Tubing Fittings (on page 518)

Socketwelded Fittings (on page 524)

Threaded Fittings (on page 527)

Underground Fittings (on page 532)

Valves (on page 535)

Welded Fittings (on page 551)

Gaskets (on page 559)

Bolting (on page 566)

Flanged and Miscellaneous Fittings


! 0 1 2
! 1 2345678901234567890
! FIRST LETTER: B - MISCELLANEOUS FITTINGS
B BA
B BB
B BC
B DA
B DD
B DT
B DY
B EA
B EC
B ED
B ET
B EY
B FR
B FT

436

Ball joint straight


thru
Ball joint 90 deg
elbow
Ball joint double 90
deg ell
Elbow female x female
45 deg elbow female x
female
Tee female x female x
female
45 deg lateral female
x female x female
Elbow male x male
Plug male
45 deg elbow male x
male
Tee male x male x male
45 deg lateral male x
male x male
Reducer male x female
Tee male x male x
female

Ball joint straight thru


Ball joint 90 deg elbow
'Ball joint double 90 deg
elbow'
'Elbow female x female'
'45 deg elbow female x female'
'Tee female x female x female'
'45 deg lateral female x female
x female'
'Elbow male x male'
'Plug male'
'45 deg elbow male x male'
'Tee male x male x male'
'45 deg lateral male x male x
male'
'Reducer male x female'
'Tee male x male x female'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions

B GY
B HA

45 deg lateral male x '45 deg lateral male x male x


male x female
female'
Grayloc assembly
'Grayloc assembly -hubs, ring,
clamp & bolts'
Grayloc orifice
'Grayloc orifice assembly
assembly
-hubs, ring, clamp & bolts'
Grayloc clamp,
'Grayloc clamp, w/bolt set'
w/bolts
Grayloc blind hub
'Grayloc blind hub'
Grayloc blind hub,
'Grayloc blind hub, w/SW tap'
w/tap
Grayloc hub
'Grayloc hub
Grayloc seal ring
'Grayloc seal ring'
Grayloc blind seal
'Grayloc blind seal ring'
ring
Grayloc bolt set
'Grayloc bolt set'
Flanged union
'Flanged union'

B LA

Flanged elbow

B LB

B VQ

Flanged reducing
elbow
Flanged 45 deg elbow
Flanged concentric
reducer
Flanged eccentric
reducer
Flanged tee
Flanged reducing tee
Flanged return bend
Flanged adapter
THD adapter
LR elbow
45 deg LR elbow
Tee
Elbow
45 deg elbow
Concentric reducer
Reducing tee
Eccentric reducer
Victaulic cap
Reducer FTSE
Coupling, w/gasket
Coupling, w/gasket &
FTE outlet
Coupling, w/gasket &
MTE outlet
Reducing tee, w/ MTE
outlet
Red tee, w/FTE outlet

B WS
B XA

Weld sleeve
Flanged cross

B FY
B GA
B GB
B GC
B GD
B GE
B GF
B GG
B GH

B LC
B RA
B RB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B

TA
TB
UA
VA
VB
VC
VD
VE
VF
VG
VH
VI
VJ
VK
VL
VM
VN

B VO
B VP

'Flanged
elbow'
'Flanged
elbow'
'Flanged
'Flanged

90 deg long radius


90 deg reducing
45 deg elbow'
concentric reducer'

'Flanged eccentric reducer'


'Flanged tee'
'Flanged reducing tee'
'Flanged return bend'
'Flanged adapter'
'Threaded adapter'
'Long radius elbow'
'45 deg long radius elbow'
'Tee'
'Elbow'
'45 deg elbow'
'Concentric reducer'
'Reducing tee'
'Eccentric reducer'
'Victaulic cap'
'Reducer threaded small end'
'Coupling, w/gasket'
'Outlet coupling, w/gasket &
female THD outlet'
'Outlet coupling, w/gasket &
male THD outlet'
'Reducing tee, w/male THD
outlet'
'Reducing tee, w/female THD
outlet'
'External weld sleeve'
'Flanged cross'

Plant Design System (PDS) Piping Component Data

437

Commodity Code Descriptions


B
B
B
B
B
B
B
B
B

YA
YB
ZA
ZB
ZC
ZD
ZE
ZF
ZN

Flanged Y
Flanged 45 deg lateral
Hub
Hub & flanged
Coupling/connector
Clamp
Cap
Flexible coupling
Nipple/connector

'Flanged true Y'


'Flanged 45 deg lateral'
'Hub'
'Hub & flanged'
'Coupling/connector'
'Clamp, w/bolts & nuts'
'Cap'
'Flexible coupling'
'Nipple/connector'

B
B
B
B
B
B
B
B
B
B
B
B
B
B

A
B
C
D
E
F
G
K
L
M
N
O
R
S

CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL25
CL125
CL250
CL800
CL175
std conn
shrouded bore
connection

CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL25
CL125
CL250
CL800
CL175
standard connection
shrouded bore connection

BZ

438

B
B
B

A
B
D

FFFE
RFFE
RFFE 125 Ra finish

RFFE 125-500 Ra finish

RFFE 63-250 Ra finish

RFFE 63-125 Ra finish

RFFE 125-250 Ra finish

B
B
B

J
L
M

RJFE
flange
flange
socket
flange
flange
flange
socket

x socket
x socket x
x socket x
x flange x

flat face flanged ends


raised face flanged ends
raised face flanged ends 125
Ra finish
raised face flanged ends
125-500 Ra finish
raised face flanged ends
63-250 Ra finish
raised face flanged ends
63-125 Ra finish
raised face flanged ends
125-250 Ra finish
ring joint flanged ends
FF flange x socket
FF flange x socket x socket
FF flange x socket x FF
flange
FF flange x FF flange x
socket

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


B

B
B
B
B
B
B
B

R
S
T
U
V
W
Z

B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B

B
C
D
E
F
G
H
I
J
L
M
N
S
X
Z
A
E
Z

socket x socket x
flange
bell & spigot
SWE
THD
MJE
grooved
welded

socket x socket x FF flange

S-40
S-80
S-XS
S-160
thk per B16.5
S-XXS
S-100
S-120
S-140
S-LW
S-20
S-30
S-STD
thk per reqn

Sch 40
Sch 80
X-strong
Sch 160
thk per ANSI-B16.5
XX-strong
Sch 100
Sch 120
Sch 140
light-weight
Sch 20
Sch 30
standard-weight
thk per specification ??

B16.1
B16.5

ANSI-B16.1
ANSI-B16.5

ASTM-A234 Gr.WPB
ASTM-A216 Gr.WCB
ASTM-A216 Gr.WCB,
galvanized
carbon steel
ASTM-A105
ASTM-A234 Gr.WPB, Victaulic
ASTM-A234 Gr.WPB,
galvanized, Victaulic
ASTM-A181 Cl.70
ASTM-A181 Cl.70, Barco
BB-41020-??-21
AISI-4140

B
B
B

AAA
AAB
AAC

ASTM-A234-WPB
ASTM-A216-WCB
ASTM-A216-WCB, galv

B
B
B
B

AAE
AAF
AAG
AAH

carbon steel
ASTM-A105
ASTM-A234-WPB
ASTM-A234-WPB

B
B

AAN
AAO

ASTM-A181-70
ASTM-A181-70

AAZ

AISI-4140

bell & spigot


socketwelded end
threaded end
mechanical joint end
grooved
welded

Plant Design System (PDS) Piping Component Data

439

Commodity Code Descriptions


B
B
B
B
B
B
B
B
B
B

ABC
EAB
EAC
EEE
FFB
FFC
FFF
FFH
FFL
IAA

ASTM-A53-B, galv
ASTM-A217-C5
ASTM-A217-C12
ASTM-A182-F1
ASTM-A182-F12
ASTM-A182-F11
ASTM-A182-F22
ASTM-A182-F5
ASTM-A182-F9
ASTM-A351-CF8M

B
B
B
B
B

IAB
IIA
IIF
IIG
IIK

IIL

B
B
B
B

IIM
IIN
UAA
WXW

ASTM-A351-CF8C
ASTM-A266-3
ASTM-A182-F316
ASTM-A182-F316L
17-4PH SS,
w/graphite
347 SS, w/graphite
coating
ASTM-A182-F347H
ASTM-A182-F347
ASTM-D2996-RTRP
ASTM-A234-WPBW

WXX

ASTM-A234-WPB

ZAC

ASTM-A536-65-45-12

ZAD
ASTM-A536-65-45-12/E
PDM

ZAE

ZAF

ZAG

ASTM-A536-65-45-12/B
una N
ASTM-A536-65-45-12
ASTM-A536-65-45-12/E
PDM

B
B
B
B
B
B

440

ZAH
ZDE
ZDF
ZDG
ZDM
ZDN

ASTM-A536-65-45-12/B
una N
ASTM-A126-A, galv
ASTM-A126-B, galv
ASTM-A47, galv
ASTM-A395
ASTM-A126-A

ASTM-A53 Gr.B, galvanized


ASTM-A217 Gr.C5
ASTM-A217 Gr.C12
ASTM-A182 Gr.F1
ASTM-A182 Gr.F12
ASTM-A182 Gr.F11
ASTM-A182 Gr.F22
ASTM-A182 Gr.F5
ASTM-A182 Gr.F9
ASTM-A351 Gr.CF8M
ASTM-A351 Gr.CF8C
ASTM-A266 Cl.3
ASTM-A182 Gr.F316
ASTM-A182 Gr.F316L
17-4 PH SS, w/graphite
347 SS, w/graphite coating
ASTM-A182 Gr.F347H
ASTM-A182 Gr.F347
ASTM-D2996-RTRP-11FE
ASTM-A234 Gr.WPBW, epoxy
lined
ASTM-A234 Gr.WPB, epoxy
lined
ASTM-A536 Gr.65-45-12,
Victaulic
ASTM-A536 Gr.65-45-12/EPDM,
Victaulic
ASTM-A536 Gr.65-45-12/Buna
N, Victaulic
ASTM-A536
galvanized,
ASTM-A536
galvanized,

Gr.65-45-12,
Victaulic
Gr.65-45-12/EPDM,
Victaulic

ASTM-A536 Gr.65-45-12/Buna
N, galvanized, Victaulic
ASTM-A126 Cl.A, galvanized
ASTM-A126 Cl.B, galvanized
ASTM-A47, galvanized
ASTM-A395, nodular iron
ASTM-A126 Cl.A, 12" &
smaller

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


B

ZDO

ASTM-A126-B

ASTM-A126 Cl.B, 14" &


larger

Completing Materials
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: C - COMPLETING MATERIALS (PDS WILL NOT USE)
C AC

Hi-temp end sealant

C AD

Primer

High temperature end


sealant
Primer

C AE
C CA

Solvent cement
Protector

Solvent cement
Protector

C
C
C
C
C

Tape
Channel trace
Heat transfer cement
Identification tag
Snap trace

Tape
Channel trace
Heat transfer cement
Identification tag
Snap trace

Chemtrol
Koch
Markad Service Co
Dekoron
Thermon
Thermon TFK-4
Thermon T-80

Chemtrol
Koch
Markad Service Co.
Dekoron

Purple Primer
heavy duty PVC solvent
cement
heavy duty CPVC solvent
cement
galvanized steel
Thermon Channel Trace,
Gr.T-3
Thermon Snap Trace,
Gr.T-63
Thermon Snap Trace,
Extruded

C
C
C
C
C
C
C
C

CB
CH
HT
ID
ST
AAAB
AAAE
DAAB
DCCC
TAAA
TAAB
TAAC
ZZZZ

C
C

AAE
AAF

Purple Primer
heavy duty PVC cement

AAG

heavy duty CPVC cement

C
C

GAA
TAA

galv steel
Thermon Channel Trace

TAB

Thermon Snap Trace

TAC

Thermon Snap Trace

ZZZ

Thermon TFK-4
Thermon T-80

Plant Design System (PDS) Piping Component Data

441

Commodity Code Descriptions

Fire and Safety Components


! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: D - FIRE & SAFETY COMPONENTS
D AA
D AC

@@Monitor, station type


Monitor, station type
@@Monitor, elevated type Monitor, elevated
type
@@Fire hydrant
Fire hydrant, dry
barrel type
Hose reel w/valve
Hose reel w/valve
@@Hose rack w/valve
Hose rack w/valve
@Spray sprinkler filld
Spray sprinkler,
cone w/rupture disk
filled cone type
w/rupture disk

D BA
D CA
D CB
D DA

D
D
D
D
D
D

@@CL125
@@CL150
CL175
@@300#
@rating per reqn

CL125
CL150
CL175
300#
rating ??

flat face flanged ends


flat face flanged end x
male thread end
male thread ends
female thread ends

D
D

A
B

@@FFFE
FFFE/FTE

D
D
D

C
D
Z

@@MTE
@@FTE

D
D
D
D
D
D
D
D

442

A
B
C
G
X
Z

A
I
J
S
V
W
X
Z

carbon steel
stainless steel
@@304 SS
brass
ductile iron
cast iron
@@matl per reqn

D
D
D

AA
AB
BA

CA

carbon steel
stainless steel
Type 304 SS
brass
ductile iron
cast iron
matl ??

@@Stang BB0309-21
Stang Model BB0309-21
@@Stang
Stang
@@American Darling B-50-B American Darling
B-50-B
Wirt & Knox V-7
Wirt & Knox V-7

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


D

DA

D
D
D
D

EA
AA
AB
BA

BB

BC

BD

BE

BF

DA

DB

@@Grinnell Mulsifyre
Projector S1

Grinnell Fire
Protection, Mulsifyre
Projector S1
@@Powhatan 30-333
Powhatan 30-333
@@

@@ccw open
counterclockwise open
free standing, [427]
free standing, [427]
w/fog nozzle
w/two reaction
supports, w/fog nozzle
supported, [427] w/fog
supported, [427]
nozzle supported, [427] w/fog nozzle
w/fog nozzle
@@free standing, [427]
free standing, [427]
w/shaper tip nozzle
w/two reaction
supports, w/shaper tip
nozzle
@@supported, [427]
supported, [427]
w/shaper tip nozzle
w/shaper tip nozzle
@@free standing w/shaper free standing w/shaper
tip nozzle
tip nozzle
@@free standing w/fog
free standing w/fog
nozzle
nozzle
@@wall mount, rt hand
wall mounted, right
w/hose & fog nozzle
hand w/hose & fog
nozzle
@wall mount, left hand
wall mounted, left
w/hose & fog nozzle
hand w/hose & fog
nozzle

Steam Specialties
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: E - STEAM SPECIALTIES
E AB
E AD

E BA
E CB

Bellows steam trap


Thermodynamic steam
trap
Ball float steam trap
Ball float liq drn
Inv bucket steam trap
Bimetallic steam trap
Open bucket steam trap
Thermostatic steam
trap
Exhaust head
Bellows steam trap

E CD

Thermodynamic steam

E
E
E
E
E
E

AF
AG
AI
AM
AO
AS

Bellows steam trap


Thermodynamic steam trap
Ball float steam trap
Ball float liquid drainer
Inverted bucket steam trap
Bimetallic steam trap
Open bucket steam trap
Thermostatic steam trap
Exhaust head
Bellows steam trap,
w/integral strainer
Thermodynamic steam trap,

Plant Design System (PDS) Piping Component Data

443

Commodity Code Descriptions


trap
w/integral strainer
Ball float steam trap Ball float steam trap,
w/integral strainer
Bimetallic steam trap Bimetallic steam trap,
w/integral strainer
Thermostatic steam
Thermostatic steam trap,
trap
w/integral strainer

E CF
E CM
E CS
E ZZ
E
E
E
E
E
E
E
E
E
E
E
E
E
E

CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL125
CL250
CL175
CL25
CL50
CL75

E
E
E

A
B
D

E
E
E
E

J
S
T
Z

E
E
E
E
E
E
E

444

A
B
C
D
E
F
G
L
M
O
R
S
T
Z

CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL125
CL250
CL175
CL25
CL50
CL75

FFFE
RFFE
RFFE, 125 Ra finish

flat face flanged ends


raised face flanged endss
raised face flanged ends,
125 Ra finish
RFFE, 125-500 Ra
raised face flanged ends,
finish
125-500 Ra finish
RFFE, 63-250 Ra finish raised face flanged ends,
63-250 Ra finish
RFFE, 63-125 Ra finish raised face flanged ends,
63-125 Ra finish
RJFE
ring joint flanged ends
SWE
socketwelded ends
THD
threaded ends

AA
AB
AC
AD
AE
AF
AG

1/16 orifice "


5/64 orifice "
3/32 orifice "
7/64 orifice "
1/8 orifice "
9/64 orifice "
5/32 orifice "

1/16 orifice "


5/64 orifice "
3/32 orifice "
7/64 orifice "
1/8 orifice "
9/64 orifice "
5/32 orifice "

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E

AH
AI
AJ
AK
AL
AM
AN
AO
AP
AQ
AR
BA
TA
TE
TF
TG
TH
TI
ZZ
AAD

AAE

AAF

AAG

AAH

AAI

AAJ

AAK

AAL

BAA

EAV

EAW

FAA

FAB

3/16 orifice "


7/32 orifice "
1/4 orifice "
9/32 orifice "
5/16 orifice "
11/32 orifice "
3/8 orifice "
7/16 orifice "
1/2 orifice "
5/8 orifice "
3/4 orifice "
No 38 orifice
274 degF
378 degF
147 degC
184 degC
236 degC
259 degC
ASTM-A105, Armstrong
71-315
ASTM-A105, Spriax
Sarco SM 21
ASTM-A105, Armstrong
411F
ASTM-A105, Spirax
Sarco PB 43/2
ASTM-A105, Spirax
Sarco SM652
ASTM-A105, ITT Hoffman
TB-6W
ASTM-A105, ITT Hoffman
CFH-TB
ASTM-A105, Armstrong
310FW
ASTM-A105, Armstrong
411G-FW
ASTM-A216-WCB,
Armstrong 981
ASTM-A182-F11, Yarway
720
ASME-SA182-F11,
Yarway 720
ASTM-A182-F11, ITT
Hoffman CH1-TB
ASTM-A182-F11, ITT
Hoffman CUH3-TB

3/16 orifice "


7/32 orifice "
1/4 orifice "
9/32 orifice "
5/16 orifice "
11/32 orifice "
3/8 orifice "
7/16 orifice "
1/2 orifice "
5/8 orifice "
3/4 orifice "
No 38 orifice
274 degF
378 degF
147 degC
184 degC'
236 degC
259 degC

ASTM-A105, Armstrong
71-315
ASTM-A105, Spriax Sarco SM
21
ASTM-A105, Armstrong 411F
ASTM-A105, Spirax Sarco PB
43/2
ASTM-A105, Spirax Sarco
SM652
ASTM-A105, ITT Hoffman
TB-6W
ASTM-A105, ITT Hoffman
CFH-TB
ASTM-A105, Armstrong
310FW
ASTM-A105, Armstrong
411G-FW
ASTM-A216 Gr.WCB,
Armstrong 981
ASTM-A182 Gr.F11,
1.25Cr-0.5Mo, Yarway 720
ASME-SA182 Gr.F11,
1.25Cr-0.5Mo, Yarway 720
ASTM-A182 Gr.F11,
1.25Cr-0.5Mo, ITT Hoffman
CH1-TB
ASTM-A182 Gr.F11,
1.25Cr-0.5Mo, ITT Hoffman
CUH3-TB

Plant Design System (PDS) Piping Component Data

445

Commodity Code Descriptions


E

FAC

ASTM-A182-F11, ITT
Hoffman CUH4-TB

FAT

FAV

FAW

GAA

GAB

ASTM-A182-F11, Yarway
515
ASTM-A182-F11, Yarway
740
ASTM-A182-F11, Yarway
710
ASTM-A217-WC9, Yarway
C-500
ASTM-A182-F22,
Armstrong 5155FG

E
E

IAA
IAB

SS, Armstrong TT-2000


SS, Armstrong 2011

IAC

IAD

ASTM-A240-304L,
Wright-Austin 40EF
SS, Armstrong 2010

ZPA

ZPB

ZPC

ASTM-A278-30, Clark
60F
ASTM-A126-A, Crane
Swartwout
ASTM-A278-30,
Armstrong J Ser LD
Model

ASTM-A182 Gr.F11,
1.25Cr-0.5Mo, ITT Hoffman
CUH4-TB
ASTM-A182 Gr.F11,
1.25Cr-0.5Mo, Yarway 515
ASTM-A182 Gr.F11,
1.25Cr-0.5Mo, Yarway 740
ASTM-A182 Gr.F11,
1.25Cr-0.5Mo, Yarway 710
ASTM-A217 Gr.WC9,
2.25Cr-1Mo, Yarway C-500
ASTM-A182 Gr.F22,
2.25Cr-1Mo, Armstrong
5155FG
SS, Armstrong TT-2000
SS, Armstrong 2011, w/CS
connector
ASTM-A240 Type 304L,
Wright-Austin 40EF
SS, Armstrong 2010, w/CS
connector
ASTM-A278 Cl.30, cast iron,
Clark 60F
ASTM-A126 Cl.A, cast iron,
Crane Swartwout
ASTM-A278 Cl.30, cast iron,
Armstrong J Series LD Model

Flanges
!
!
!
F
F
F
F
F
F
F
F
F
F
F
F
F

446

0 1 2
1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
FIRST LETTER: F - FLANGES
A
@@Flange, WN
Flange, weld neck
B
@@Blind flange
Blind flange
C
@@Flange, SW
Flange, socketwelded
D
@@Flange, THD
Flange, threaded
E
@@Flange, slip-on
Flange, slip-on
F
@@Flange, lap joint
Flange, lap joint
G
@@Orifice flange, WN
Orifice flange, weld neck
H
SW orifice flange
Socketwelded orifice
flange
I
@@Orifice flange, THD
Orifice flange, threaded
J
Slip-on orifice flange Slip-on orifice flange
L
Long WN flange
Long weld neck flange
M
Solder joint flange
Solder joint flange per
ANSI-B16.24
N
@@Flange, SE
Flange, socket end

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


F
F
F
F

R
S
T
U

Red
Red
Red
Red

F V
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F

AA
AB
AC
AD
AE
AF
AG
AX
BA
BB
BC
BD
BE
BH
BO
BP
BQ
BR
BS
BT
CA
CB
CD
CE
DA
DB
DC
DD
OA
OB
OC
OD
OE
OF
OG
PB

WN flange
slip-on flange
THD flange
SW flange

Victaulic flange

Reducing weld neck flange


Reducing slip-on flange
Reducing threaded flange
Reducing socketwelded
flange
Victaulic flange

@@ANSI-B16.5 CL150
@@ANSI-B16.5 CL300
ANSI-B16.5 CL400
@@ANSI-B16.5 CL600
@@ANSI-B16.5 CL900
@@ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
rating per reqn
@@API-605 CL150
@@API-605 CL300
API-605 CL400
API-605 CL600
API-605 CL900
API-605 CL75
API-6A CL2000
API-6A CL3000
API-6A CL5000
API-6A CL10000
API-6A CL15000
API-6A CL20000
@@MSS-SP-44 CL150
@@MSS-SP-44 CL300
@@MSS-SP-44 CL600
MSS-SP-44 CL900
ANSI-B16.1 CL25
ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
ANSI-B16.36 CL150
ANSI-B16.36 CL300
ANSI-B16.36 CL400
ANSI-B16.36 CL600
ANSI-B16.36 CL900
ANSI-B16.36 CL1500
ANSI-B16.36 CL2500
@@ANSI-B16.36 CL300,

ANSI-B16.5 CL150
ANSI-B16.5 CL300
ANSI-B16.5 CL400
ANSI-B16.5 CL600
ANSI-B16.5 CL900
ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
rating ??
API-605 CL150
API-605 CL300
API-605 CL400
API-605 CL600
API-605 CL900
API-605 CL75
API-6A CL2000
API-6A CL3000
API-6A CL5000
API-6A CL10000
API-6A CL15000
API-6A CL20000
MSS-SP-44 CL150
MSS-SP-44 CL300
MSS-SP-44 CL600
MSS-SP-44 CL900
ANSI-B16.1 CL25
ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
ANSI-B16.36 CL150
ANSI-B16.36 CL300
ANSI-B16.36 CL400
ANSI-B16.36 CL600
ANSI-B16.36 CL900
ANSI-B16.36 CL1500
ANSI-B16.36 CL2500
ANSI-B16.36 CL300, 0.5 SWE

Plant Design System (PDS) Piping Component Data

447

Commodity Code Descriptions

448

PC

PD

PE

PF

PG

PM

PN

PO

PP

PR

PS

QB

F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F

SA
SB
SC
SD
SE
SF
SG
SH
SI
TA
TB
TC
TD
TE
TF
TG
ZZ

F
F
F

A
B
D

0.5 SWE tap "


ANSI-B16.36 CL400 0.5
SWE tap "
@@ANSI-B16.36 CL600,
0.5 SWE tap "
ANSI-B16.36 CL900 0.5
SWE tap "
ANSI-B16.36 CL1500 0.5
SWE tap "
ANSI-B16.36 CL2500 0.5
SWE tap "
ANSI-B16.36 CL150 0.75
SWE tap "
@@ANSI-B16.36 CL300,
0.75 SWE tap "
ANSI-B16.36 CL400 0.75
SWE tap "
@@ANSI-B16.36 CL600,
0.75 SWE tap "
@@ANSI-B16.36 CL1500,
0.75 SWE tap "
ANSI-B16.36 CL2500 0.75
SWE tap "
@@ANSI-B16.36 CL300,
0.5 FTE tap "
@@CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL250
CL175
@@AWWA-C207 Cl.D
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350

tap "
ANSI-B16.36 CL400 0.5 SWE
tap "
ANSI-B16.36 CL600, 0.5 SWE
tap "
ANSI-B16.36 CL900 0.5 SWE
tap "
ANSI-B16.36 CL1500 0.5 SWE
tap "
ANSI-B16.36 CL2500 0.5 SWE
tap "
ANSI-B16.36 CL150 0.75 SWE
tap "
ANSI-B16.36 CL300, 0.75
SWE tap "
ANSI-B16.36 CL400 0.75 SWE
tap "
ANSI-B16.36 CL600, 0.75
SWE tap "
ANSI-B16.36 CL1500, 0.75
SWE tap "
ANSI-B16.36 CL2500 0.75
SWE tap "
ANSI-B16.36 CL150, 0.5 FTE
tap "
CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL250
CL175
AWWA-C207 Cl.DA
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350

@@FFFE
@@RFFE
@@RFFE, 125 Ra finish

flat face flanged end


raised face flanged end
raised face flanged end,
125 Ra finish
RFFE, 125-500 Ra finish raised face flanged end,

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions

F
F
F

J
L
N

125-500 Ra finish
RFFE, 63-250 Ra finish raised face flanged end,
63-250 Ra finish
RFFE, 63-125 Ra finish raised face flanged end,
63-125 Ra finish
RFFE, 125-250 Ra finish raised face flanged end,
125-250 Ra finish
@@RJFE
ring joint flanged end
lens joint
lens joint flanged end
RFFE, 3 Ra finish
raised face flanged end, 3
Ra finish
@@

F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F

AA
AB
AC
AD
AF
AG
AH
AI
AJ
AK
AL
AM
AN
AO
AW
BA
BB
BC
BD
CA
CB
CC
CD
CE
CF
CG
CH
CI
CJ
CK
CL

S-5S
S-10S
@@S-40S
@@S-80S
S-10
S-20
S-30
S-40
S-60
@@S-80
S-100
S-120
S-140
@@S-160
@@[???]
S-LW
S-STD
S-XS
@@S-XXS
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "

Plant Design System (PDS) Piping Component Data

Sch 5S
Sch 10S
Sch 40S
Sch 80S
Sch 10
Sch 20
Sch 30
Sch 40
Sch 60
Sch 80
Sch 100
Sch 120
Sch 140
Sch 160
[???]
light-weight
standard-weight
X-strong
XX-strong
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "

449

Commodity Code Descriptions


F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F

450

CM
CN
CO
CP
CQ
CR
CS
CT
CU
CV
CW
CX
DD
EA
VEB
VED
EE
EF
EG
EH
FE
MA
MB
MC
MD
ME
MF
MG
MH
MI
MJ
MK
ML
MM
MN
MO
MP
MQ
MR
MS
MT
MU

0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.75 "
1.875 "
0.281 "
2 "
2.125 "
2.375 "
2.5 "
2.625 "
2.75 "
2.875 "
3.5 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm

0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.75 "
1.875 "
0.281 "
2 "
2.125 "
2.375 "
2.5 "
2.625 "
2.75 "
2.875 "
3.5 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F

MV
PA
PB
PC
PD
PE
PF
PG
PH
PI
PJ
PK
PL
PM
PN
PO
PP
PQ
PR
PS
PZ
QF
ZZ

100.0 mm
3.2 mm
4.8 mm
6.4 mm
7.9 mm
9.5 mm
11.1 mm
12.7 mm
14.3 mm
15.9 mm
17.5 mm
19.1 mm
20.6 mm
22.2 mm
23.8 mm
25.4 mm
27.0 mm
28.6 mm
30.2 mm
31.8 mm
29.0 mm
26.0 mm
@@

100.0 mm
3.2 mm (0.125")
4.8 mm (0.188")
6.4 mm (0.25")
7.9 mm (0.312")
9.5 mm (0.375")
11.1 mm (0.438")
12.7 mm (0.5")
14.3 mm (0.562")
15.9 mm (0.625")
17.5 mm (0.688")
19.1 mm (0.75")
20.6 mm (0.812")
22.2 mm (0.875")
23.8 mm (0.938")
25.4 mm (1")
27.0 mm (1.062")
28.6 mm (1.125")
30.2 mm (1.188")
31.8 mm (1.25")
29.0 mm (1.142")
26.0 mm

ASTM-A105
ASTM-A105, aluminized
ASTM-A105, treated &
wrapped
ASTM-A105, galvanized
ASTM-A105, aluminized,
treated & wrapped
ASTM-A350 Gr.LF2
ASME-SA105
ASTM-A182 Gr.F12,
1Cr-0.5Mo
ASTM-A182 Gr.F11
ASTM-A182 Gr.F22,
2.25Cr-1Mo
ASTM-A182 Gr.F21,
3Cr-1Mo
ASTM-A182 Gr.F5
ASTM-A182 Gr.F5A,
5Cr-0.5Mo
ASTM-A182 Gr.F7,
7Cr-0.5Mo

F
F
F

AAA
AAB
AAC

@@ASTM-A105
ASTM-A105, alum
ASTM-A105 T&W

F
F

AAH
AAI

@@ASTM-A105, galv
ASTM-A105 alum T&W

F
F
F

ABB
ABE
FFB

@@ASTM-A350-LF2
@@ASME-SA105
ASTM-A182-F12

F
F

FFC
FFF

@@ASTM-A182-F11
ASTM-A182-F22

FFG

ASTM-A182-F21

F
F

FFH
FFI

@@ASTM-A182-F5
ASTM-A182-F5A

FFK

ASTM-A182-F7

Plant Design System (PDS) Piping Component Data

451

Commodity Code Descriptions

452

F
F
F

FFL
GFD
GFF

@@ASTM-A182-F9
@@ASME-SA182-F11
ASME-SA182-F22

F
F
F

IIA
IIB
IIC

F
F
F
F
F
F
F
F
F
F
F
F

IIE
IIF
IIG
IIH
IIJ
IIK
IIL
IIN
IIO
IIP
IIY
IJF

@@ASTM-A182-F304
@@ASTM-A182-F304L
ASTM-A182-F316L,
w/0.03% C max
ASTM-A182-F310
@@ASTM-A182-F316
ASTM-A182-F316L
ASME-SA182-F316L
@@ASTM-A182-F321
ASTM-A182-F321H
ASTM-A182-F347
ASTM-A182-F348
ASME-SA182-F316
ASTM-A182-F304H
ASTM-A182-F347H
ASTM-A182-F316L,
special

F
F
F
F

IKA
MLF
NPE
NPF

OAA

ASTM-A451-HF modified
ASTM-A350-LF3
ASTM-B62 bronze
@@ASTM-B166-600, hot
finish
ASTM-B564 Monel

OAC

ASTM-B564 Incoloy 800

PAA

ASTM-B462 Alloy 20

TAA

ASTM-F439 CPVC

TAB

@@ASTM-D2467 PVC

WAA

WAB

F
F

WAC
WAD

F
F

WXW
ZAD

@@ASTM-A105, cement
lined
ASTM-A105, cement lined
& epoxy coated
ASTM-A105, epoxy coated
ASTM-A105, cement lined
& T&W
ASTM-A105 epoxy lined
ASTM-A536-65-45-12/EPD
M

ASTM-A182 Gr.F9
ASME-SA182 Gr.F11
ASME-SA182 Gr.F22,
2.25Cr-1Mo
ASTM-A182 Gr.F304
ASTM-A182 Gr.F304L
ASTM-A182 Gr.F316L,
w/0.03% C max
ASTM-A182 Gr.F310
ASTM-A182 Gr.F316
ASTM-A182 Gr.F316L
ASME-SA182 Gr.F316L
ASTM-A182 Gr.F321
ASTM-A182 Gr.F321H
ASTM-A182 Gr.F347
ASTM-A182 Gr.F348
ASME-SA182 Gr.F316
ASTM-A182 Gr.F304H
ASTM-A182 Gr.F347H
ASTM-A182 Gr.F316L,
w/0.036% C max, 12% Ni min,
2.2% Mo min
ASTM-A451 Gr.HF modified
ASTM-A350 Gr.LF3, 3.5 Ni
ASTM-B62 bronze
ASTM-B166 Gr.600 UNS
N06600, hot finish
ASTM-B564 UNS N04400,
Monel
ASTM-B564 UNS NO8800,
Incoloy 800
ASTM-B462 UNS N08020,
Alloy 20
ASTM-F439 Cl.23447-B,
CPVC
ASTM-D2467 Cl.12454-B
PVC
ASTM-A105, cement lined
ASTM-A105, cement lined &
epoxy coated
ASTM-A105, epoxy coated
ASTM-A105, cement lined,
treated & wrapped
ASTM-A105, epoxy lined
ASTM-A536
Gr.65-45-12/EPDM, ductile
iron, Victaulic

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


F

ZAE

ASTM-A536-65-45-12/Bun
a N

ZAG

ASTM-A536-65-45-12/EPD
M

ZAH

ASTM-A536-65-45-12/Bun
a N

ASTM-A536
Gr.65-45-12/Buna N,
ductile iron, Victaulic
ASTM-A536
Gr.65-45-12/EPDM, ductile
iron, galvanized,
Victaulic
ASTM-A536
Gr.65-45-12/Buna N,
ductile iron, galvanized,
Victaulic

Flanged Fittings
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: G - FLANGED FITTINGS
G A
Flange isolation kit
Flange isolation kit
G D
Spacer
Spacer for plastic pipe
G E
@@Paddle spacer
Paddle spacer
G F
Paddle spacer for
Paddle spacer for
maintenance blank
maintenance blank
G G
Bleed ring, w/THD tap Bleed ring, w/threaded
tap
G H
Bleed ring, w/SWE tap Bleed ring,
w/socketwelded end tap
G J
@@Spectacle blank
Spectacle blank
G L
@@Paddle blank
Paddle blank
G M
Maint type paddle
Maintenance type paddle
blank
blank
G N
@@Blank disc
Blank disc
G O
3-bolt blank assy
Three bolt blank
assembly
G P
5-bolt blank assy
Five bolt blank assembly
G Q
7-bolt blank assy
Seven bolt blank
assembly
G U
Union blank
Union blank
G
G
G
G
G
G
G
G
G

A
AB
AC
AD
AE
AF
AG
BA
BB

@@ANSI-B16.5 CL150
ANSI-B16.5 CL300
ANSI-B16.5 CL400
ANSI-B16.5 CL600
ANSI-B16.5 CL900
ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
API-605 CL150
API-605 CL300

Plant Design System (PDS) Piping Component Data

ANSI-B16.5 CL150
ANSI-B16.5 CL300
ANSI-B16.5 CL400
ANSI-B16.5 CL600
ANSI-B16.5 CL900
ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
API-605 CL150
API-605 CL300

453

Commodity Code Descriptions

454

G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G

BC
BD
BE
BH
BO
BP
BQ
BR
BS
BT
CA
CB
CD
DA
DB
DC
DD
FA
FB
FD

API-605 CL400
API-605 CL600
API-605 CL900
API-605 CL75
API-6A CL2000
API-6A CL3000
API-6A CL5000
API-6A CL10000
API-6A CL15000
API-6A CL20000
@@MSS-SP-44 CL150
@@MSS-SP-44 CL300
@@MSS-SP-44 CL600
ANSI-B16.1 CL25
ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
@@API-590 CL150
@@API-590 CL300
@@API-590 CL600

API-605 CL400
API-605 CL600
API-605 CL900
API-605 CL75
API-6A CL2000
API-6A CL3000
API-6A CL5000
API-6A CL10000
API-6A CL15000
API-6A CL20000
MSS-SP-44 CL150
MSS-SP-44 CL300
MSS-SP-44 CL600
ANSI-B16.1 CL25
ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
API-590 CL150
API-590 CL300
API-590 CL600

>

G
G
G
G

FE
FF
FG
GA

>

GB

>

GD

>

GE

>

GF

GG

>

HA

>

HB

>

HD

>

HE

>

HF

HG

@@API-590 CL900
@@API-590 CL1500
API-590 CL2500
@@API-590Z1 CL150,
w/0.125 CA "
@@API-590Z1 CL300,
w/0.125 CA "
@@API-590Z1 CL600,
w/0.125 CA "
@@API-590Z1 CL900,
w/0.125 CA "
@@API-590Z1 CL1500,
w/0.125 CA "
API-590 CL2500,
w/0.125 CA "
@@API-590Z2 CL150,
w/0.25 CA "
@@API-590Z2 CL300,
w/0.25 CA "
@@API-590Z2 CL600,
w/0.25 CA "
@@API-590Z2 CL900,
w/0.25 CA "
@@API-590Z2 CL1500,
w/0.25 CA "
API-590 CL2500, w/0.25
CA "

API-590 CL900
API-590 CL1500
API-590 CL2500
API-590 CL150, w/0.125
corrosion allowance "
API-590 CL300, w/0.125
corrosion allowance "
API-590 CL600, w/0.125
corrosion allowance "
API-590 CL900, w/0.125
corrosion allowance "
API-590 CL1500, w/0.125
corrosion allowance "
API-590 CL2500, w/0.125
CA "
API-590 CL150, w/0.25
corrosion allowance "
API-590 CL300, w/0.25
corrosion allowance "
API-590 CL600, w/0.25
corrosion allowance "
API-590 CL900, w/0.25
corrosion allowance "
API-590 CL1500, w/0.25
corrosion allowance "
API-590 CL2500, w/0.25
CA "

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


G
G
G
G
G
G

SA
SB
SC
SD
SE
SF

CL150
CL300
CL400
CL600
CL900
CL1500

CL150
CL300
CL400
CL600
CL900
CL1500

G
G
G
G
G
G
G
G
G
G

SG
SH
SI
TA
TB
TC
TD
TE
TF
TG

CL2500
CL250
CL175
AWWA-C207 Cl.E
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350

CL2500
CL250
CL175
AWWA-C207 Cl.E
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350

FFFE

flat face flanged ends

G
G

B
D

RFFE
RFFE, 125 Ra finish

G
G
G
G

J
M
N
R

G
G
G
G

S
T
W
Z

G
G
G
G
G
G

raised face flanged ends


raised face flanged ends,
125 Ra finish
RFFE, 125-500 Ra
raised face flanged ends,
finish
125-500 Ra finish
RFFE, 63-250 Ra finish raised face flanged ends,
63-250 Ra finish
RFFE, 63-125 Ra finish raised face flanged ends,
63-125 Ra finish
RFFE, 125-250 Ra
raised face flanged ends,
finish
125-250 Ra finish
RJFE
ring joint flanged ends
BW x flange
buttweld x RF flange
flange x BW
RF flange x buttweld
RFFE, 3 Ra finish
raised face flanged
ends, 3 Ra finish
SWE
socketwelded ends
THD
threaded
B
buttweld

AA
AB
AC
AD
AF
AG

S-5S
S-10S
S-40S
S-80S
S-10
S-20

Plant Design System (PDS) Piping Component Data

Sch
Sch
Sch
Sch
Sch
Sch

5S
10S
40S
80S
10
20

455

Commodity Code Descriptions


G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G

456

AH
AI
AJ
AK
AL
AM
AN
AO
AW
BA
BB
BC
BD
CA
CB
CC
CD
CE
CCF
CG
CH
CI
CJ
CK
CL
CM
CN
CO
CP
CQ
CR
CS
DD
MA
MB
MC
MD
ME
MF
MG
MH
MJ

S-30
S-40
S-60
S-80
S-100
S-120
S-140
S-160
[???]|bore to match|
S-LW
S-STD
S-XS
S-XXS
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188"
1.25 "
0.281 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
8.0 mm

Sch 30
Sch 40
Sch 60
Sch 80
Sch 100
Sch 120
Sch 140
Sch 160
[???]
light-weight
standard-weight
X-strong
XX-strong
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125"
1.188"
1.25 "
0.281 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
8.0 mm

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G

MK
ML
MM
MN
MO
MP
MQ
MR
MS
MT
MU
MV
PA
PB
PC
PD
PE
PF
PG
PH
PI
PJ
PK
PL
PM
PN
PO
PP
PQ
PR
PS
ZZ

10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
3.2 mm
4.8 mm
6.4 mm
7.9 mm
9.5 mm
11.1 mm
12.7 mm
14.3 mm
15.9 mm
17.5 mm
19.1 mm
20.6 mm
22.2 mm
23.8 mm
25.4 mm
27.0 mm
28.6 mm
30.2 mm
31.8 mm
@@

10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
3.2 mm (0.125) "
4.8 mm (0.188) "
6.4 mm (0.25) "
7.9 mm (0.312) "
9.5 mm (0.375) "
11.1 mm (0.438) "
12.7 mm (0.5) "
14.3 mm (0.562) "
15.9 mm (0.625) "
17.5 mm (0.688) "
19.1 mm (0.75) "
20.6 mm (0.812) "
22.2 mm (0.875) "
23.8 mm (0.938) "
25.4 mm (1) "
27.0 mm (1.062) "
28.6 mm (1.125) "
30.2 mm (1.188) "
31.8 mm (1.25) "

ASTM-A516 Gr.60
ASME-SA516 Gr.60
ASTM-A516 Gr.60, hot dip
galvanized after
fabrication
ASTM-A285 Gr.C
ASTM-A285 Gr.C, hot dip
galvanized to ASTM-A123
ASTM-A515 Gr.70, Mack
Iron
ASTM-A105, w/Teflon

G
G
G

AAA
AAB
AAC

ASTM-A516-60
ASME-SA516-60
ASTM-A516-60, galv

G
G

ABA
ABB

ASTM-A285-C
ASTM-A285-C

ABN

ASTM-A515-70

ABS

ASTM-A105/TFE, galv

Plant Design System (PDS) Piping Component Data

457

Commodity Code Descriptions

458

ABT

ABY

G
G

ADA
ADB

ADC

>

G
G
G

ADD
ADE
ADF

>

ADG

AEA

G
G

EAA
FAA

FAB

FAC

FAD

G
G
G
G

FAE
FAF
FAG
GFA

G
G
G
G
G
G
G
G
G
G

GFG
IAA
IIG
IIH
IIJ
IIL
IJA
IJB
IJC
IJD

seals, galvanized,
Greenwood
ASTM-A105/TFE
ASTM-A105, w/Teflon
seals, Greenwood
ASTM-A105/Hycar
ASTM-A105, w/Hycar seals,
Greenwood
@@ASTM-A516-70
ASTM-A516 Gr.70
ASTM-A516-60
ASTM-A516 GR 60, w/0.125
thk Monel clading
ASTM-B127 UNS N04400
@@ASTM-A516-70, galv
ASTM-A516 Gr.70,
galvanized
ASTM-A516-65
ASTM-A516 Gr.65
@@ASME-SA516-70
ASME-SA516 Gr.70
@@ASTM-A516-70,
ASTM-A516 Gr.70, Aitken,
Aitken Z1, w/0.125 CA " w/0.125 corrosion
allowance "
@@ASTM-A516-70,
ASTM-A516 Gr.70, Aitken,
Aitken Z2, w/0.25 CA " w/0.25 corrosion
allowance "
ASTM-A420-WPL6
ASTM-A420 Gr.WPL6, low
temp CS, w/Teflon seals,
Greenwood
ASTM-A204-A
ASTM-A204 Gr.A, C-Mo
ASTM-A387-5 Cl.1
ASTM-A387 Gr.5, Cl.1,
5Cr
ASTM-A387-9 Cl.1
ASTM-A387 Gr.9, Cl.1,
9Cr
ASTM-A387-11 Cl.1
ASTM-A387 Gr.11, Cl.1,
1.25Cr
ASTM-A387-22 Cl.1
ASTM-A387 Gr.22, Cl.1,
2.25Cr
@@ASTM-A387-5 Cl.2
ASTM-A387 Gr.5, Cl.2
@@ASTM-A387-9 Cl.2
ASTM-A387 Gr.9, Cl.2
@@ASTM-A387-11 Cl.2
ASTM-A387 Gr.11, Cl.2
ASME-SA387-11 Cl.1
ASME-SA387 Gr.11, Cl.1,
1.25Cr
@@ASME-SA387-11 Cl.2
ASME-SA387 Gr.11, Cl.2
ASTM-A167-316
ASTM-A167 Type 316
ASTM-A240-316L
ASTM-A240 Type 316L
ASTM-A167-304L
ASTM-A167 Type 304L
ASTM-A167-321
ASTM-A167 Type 321
ASTM-A167-347
ASTM-A167 Type 347
@@ASTM-A240-304
ASTM-A240 Type 304
ASTM-A240-304H
ASTM-A240 Type 304H
@@ASTM-A240-304L
ASTM-A240 Type 304L
@@ASTM-A240-304,
ASTM-A240 Type 304,
Aitken, w/0.125 CA "
Aitken, w/0.125 corrosion
allowance "

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


G

IJE

G
G
G
G

IJI
IJJ
IJL
IJT

OAE

PAA

TGL

TGM

TGN

TGQ

TGR

@@ASTM-A240-316,
Aitken, w/0.125 CA "

ASTM-A240 Type 316,


Aitken, w/0.125 corrosion
allowance "
@@ASTM-A240-316
ASTM-A240 Type 316
@@ASTM-A240-321
ASTM-A240 Gr.TP321
ASTM-A240-347
ASTM-A240 Type 347
TP304 SS, w/TFE seals Type 304 SS, w/Teflon
seals, Greenwood
ASTM-B127
ASTM-B127 UNS N04400,
Monel
ASTM-B463
ASTM-B463 UNS N08020,
Alloy 20
phenolic gasket
phenolic gasket neoprene
facing, w/sleeve & washer,
Maloney E
phenolic gasket
phenolic gasket, w/sleeve
& washer
phenolic gasket
phenolic gasket neoprene
facing, w/sleeve & washer,
Maloney E modified
phenolic gasket
phenolic gasket neoprene
facing, w/extra long
sleeve & Maloney E,
modified
phenolic gasket
phenolic GSKT neoprene
fcng, w/extra long sleeve &
washer, Maloney E,
modified

Strainer Specialties
!
!
!
H
H
H
H
H
H

0 1 2
1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
FIRST LETTER: H - STRAINER SPECIALTIES
A
Basket strainer
Basket strainer
B
Temp basket strainer Temporary basket strainer
C
Cone strainer
Cone strainer
F
Flat strainer
Flat strainer
I
Inv cone strainer
Inverted cone strainer
P
Inclin perf pl
Inclined perforated strainer
strainer
H U
T-type thru strainer Tee-type assembly straight
thru pattern strainer
H V
T-type angle strainer Tee-type assembly angle
pattern strainer
H Y
Y-type strainer
Y-pattern strainer
H
H

AA
AB

ANSI-B16.5 CL150
ANSI-B16.5 CL300

ANSI-B16.5 CL150
ANSI-B16.5 CL300

Plant Design System (PDS) Piping Component Data

459

Commodity Code Descriptions

460

H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H

AC
AD
AE
AF
AG
BA
BB
BH
CA
CB
CD
DA
DB
DC
DD
SA
SB
SC
SD
SE
SF
SG
SH
SI
TA
TB
TC
TD
TE
TF
TG
A
B
D

ANSI-B16.5 CL400
ANSI-B16.5 CL600
ANSI-B16.5 CL900
ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
API-605 CL150
API-605 CL300
API-605 CL75
MSS-SP-44 CL150
MSS-SP-44 CL300
MSS-SP-44 CL600
ANSI-B16.1 CL25
ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL250
CL175
AWWA-C207 Cl.E
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350
FFFE
RFFE
RFFE, 125 Ra finish

ANSI-B16.5 CL400
ANSI-B16.5 CL600
ANSI-B16.5 CL900
ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
API-605 CL150
API-605 CL300
API-605 CL75
MSS-SP-44 CL150
MSS-SP-44 CL300
MSS-SP-44 CL600
ANSI-B16.1 CL25
ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL250
CL175
AWWA-C207 Cl.E
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350
flat face flanged ends
raised face flanged ends
raised face flanged ends, 125
Ra finish
RFFE, 125-500 Ra
raised face flanged ends,
finish
125-500 Ra finish
RFFE, 63-250 Ra finish raised face flanged ends,
63-250 Ra finish
RFFE, 63-125 Ra finish raised face flanged ends,
63-125 Ra finish
RFFE, 125-250 Ra
raised face flanged ends,
finish
125-250 Ra finish
RJFE
ring joint flanged ends

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


H
H
H

M
N
R

BW x flange
flange x BW
RFFE, 3 Ra finish

H
H
H
H

S
T
W
Z

SWE
THD
BW

H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H

AA
AB
AC
AD
AF
AG
AH
AI
AJ
AK
AL
AM
AN
AO
AW
BA
BB
BC
BD
CA
CB
CC
CD
CE
CF
CG
CH
CI
CJ
CK
CL
CM
CN
CO

S-5S
S-10S
S-40S
S-80S
S-10
S-20
S-30
S-40
S-60
S-80
S-100
S-120
S-140
S-160
[???]|bore to match|
S-LW
S-STD
S-XS
S-XXS
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "

buttweld x RF flange
RF flange x buttweld
raised face flanged ends, 3 Ra
finish
socketwelded ends
threaded
buttwelded

Sch 5S
Sch 10S
Sch 40S
Sch 80S
Sch 10
Sch 20
Sch 30
Sch 40
Sch 60
Sch 80
Sch 100
Sch 120
Sch 140
Sch 160
[???]
light-weight
standard-weight
X-strong
XX-strong
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "

Plant Design System (PDS) Piping Component Data

461

Commodity Code Descriptions


H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H

462

CP
CQ
CR
CS
DD
MA
MB
MC
MD
ME
MF
MG
MH
MI
MK
MM
MN
MO
MP
MQ
MR
MS
MT
MU
MV
PA
PB
PC
PD
PE
PF
PG
PH
PI
PJ
PK
PL
PM
PN
PO
PP
PQ

1.062 "
1.125 "
1.188 "
1.25 "
0.281 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
10.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
3.2 mm
4.8 mm
6.4 mm
7.9 mm
9.5 mm
11.1 mm
12.7 mm
14.3 mm
15.9 mm
17.5 mm
19.1 mm
20.6 mm
22.2 mm
23.8 mm
25.4 mm
27.0 mm
28.6 mm

1.062 "
1.125 "
1.188 "
1.25 "
0.281 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
10.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
3.2 mm (0.125) "
4.8 mm (0.188) "
6.4 mm (0.25) "
7.9 mm (0.312) "
9.5 mm (0.375) "
11.1 mm (0.438) "
12.7 mm (0.5) "
14.3 mm (0.562) "
15.9 mm (0.625) "
17.5 mm (0.688) "
19.1 mm (0.75) "
20.6 mm (0.812) "
22.2 mm (0.875) "
23.8 mm (0.938) "
25.4 mm (1) "
27.0 mm (1.062) "
28.6 mm (1.125) "

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


H
H
H

PR
PS
ZZ

30.2 mm
31.8 mm

30.2 mm (1.188) "


31.8 mm (1.25) "

CS, 33-0.125 diam holes per


in*2
CS, 33-0.125 diam holes per
in*2 ack Iron BT-W
CS, 10 mesh 0.028 SS screen
CS, 80 mesh Monel screen,
Mueller 862
CS, 0.125 perf
CS, 20 mesh 0.016 SS screen
ASTM-A516 Gr.60, 33-0.125 diam
holes per in*2 PBL
ASTM-A516 Gr.60, 33-0.125 diam
holes per in*2 PCS
ASTM-A516 Gr.60, 33-0.125 diam
holes per in*2 PCL
ASTM-A516 Gr.60, 33-0.125 diam
holes per in*2 PBS
ASTM-A516 Gr.60, 33-0.156 diam
holes per in*2 inside, Mack Iron
PCS
ASTM-A516 Gr.60, 33-0.125 diam
holes per in*2 Iron PCS mod

AAD

CS, w/SS screen

AAE

CS, w/SS screen

H
H

AAF
AAJ

CS, w/SS screen


CS, w/Monel screen

H
H
H

AAL
AAS
ACA

CS
CS, w/SS screen
ASTM-A516-60

ACB

ASTM-A516-60

ACE

ASTM-A516-60

ACG

ASTM-A516-60

ACH

ASTM-A516-60, w/SS
screen

ACK

ASTM-A516-60

ACM

ACN

ACP

ACQ

ACR

ADD

ASTM-A216-WCB,
screen
ASTM-A216-WCB,
screen
ASTM-A352-LCB,
screen
ASTM-A216-WCB,
screen
ASTM-A216-WCB,
screen
ASTM-A516-60

ADE

ASTM-A216-WCB, w/SS
screen

FFP

ASTM-A217-WC6, w/SS
screen

FFR

IAB

ASTM-A182-F22, w/SS
screen
316 SS/LO CS

IID

w/SS
w/SS
w/SS
w/SS
w/SS

ASTM-A351-CF8M, w/SS
screen

ASTM-A216 Gr.WCB, 20 mesh SS


screen, Mueller 860 Series
ASTM-A216 Gr.WCB, 20 mesh SS
screen, Mueller 760 Series
ASTM-A352 Gr.LCB, SS screen,
Mueller 862-BC
ASTM-A216 Gr.WCB, 0.045 SS
screen
ASTM-A216 Gr.WCB, 100 mesh SS
screen, Mueller 860 Series
ASTM-A516 Gr.60, 16 Ga,
132-0.063 diam holes per in*2
Iron PBS
ASTM-A216 GR WCB/SS screen,
33-0.125 diam holes per in*2
Mueller 860 Series
ASTM-A217 Gr.WC6,
1.25Cr-0.5Mo, 30 mesh SS screen,
Mueller
ASTM-A182 Gr.F22, 2.25Cr,
0.045 SS screen
316 SS basket, low CS gasket
ring, Winston 51P
ASTM-A351 Gr.CF8M 316 SS, 0.125
diam holes Mueller 760 Series

Plant Design System (PDS) Piping Component Data

463

Commodity Code Descriptions

464

IIE

ASTM-A351-CF3M, w/SS
screen
ASTM-A351-CF8, w/SS
screen
ASTM-A351-CF8, w/SS
screen
ASTM-A351-CF8M

IIG

IIH

IIJ

H
H
H

IJP
IJR
IJS

304 SS, w/SS screen


304 SS, w/SS screen
ASTM-A240-304, w/SS
screen

IJT

ASTM-A240-304, w/SS
screen

IJU

ASTM-A240-316

IJV

ASTM-A240-316

IJW

ASTM-A240-304

IJX

ASTM-A240-304

IJY

ASTM-A240-304

IKA

ASTM-A240-304, w/SS
screen

IKB

ASTM-A240-304, w/SS
screen

IKC

ASTM-A240-321, w/SS
screen

IKD

IKE

ASTM-A240-321, w/SS
screen
ASTM-A351-CF8C

IKF

316 SS, w/SS screen

IKG

CS, w/SS screen

PAA

ASTM-A351-CN7M,
w/Alloy 20 screen

ZAA

ASTM-A395, w/SS
screen

ASTM-A351 Gr.CF3M, 316L SS,


0.057 SS screen Mueller
ASTM-A351 Gr.CF8, 304 SS, 0.045
SS screen Series
ASTM-A351 Gr.CF8, 304 SS, 0.033
SS screen Series
ASTM-A351 GR CF8M, 33-0.125
diam holes per in*2 Series
304 SS, 20 mesh 0.016 SS screen
304 SS, 20 mesh 0.016 SS screen
ASTM-A240 Type 304, 33-0.125
diam holes per in*2 Mack Iron
PBL
ASTM-A240 Type 304, 33-0.125
diam holes per in*2 Mack Iron
PBL
ASTM-A240 Type 316, 33-0.125
diam holes per in*2 PCS
ASTM-A240 Type 316, 33-0.125
diam holes per in*2 PBS
ASTM-A240 Type 304, 33-0.125
diam holes per in*2 PBL
ASTM-A240 Type 304, 33-0.125
diam holes per in*2 PBS
ASTM-A240 Type 304, 33-0.125
diam holes per in*2 PCS
ASTM-A240 Type 304, 33-0.125
diam holes per in*2 lined, Mack
Iron PBS
ASTM-A240 Type 304, 33-0.125
diam holes per in*2 covered,
Mack Iron PBS
ASTM-A240-Type 321, 33-0.125
diam holes per in*2 covered,
Mack Iron PBS lined, Mack Iron
PBS
ASTM-A240-Type 321, 33-0.125
diam holes per in*2
ASTM-A351 Gr.CF8C, 347 SS,
Mueller 862-BC
316 SS, 33-0.125 holes per in*2
w/0.02 wire diam "
CS, 33-0.125 diam holes per
in*2 20X20, w/0.02 wire diam "
ASTM-A351 Gr.CN7M, 33-0.125
diam holes per in*2 Alloy 20 "
screen, Ladish 6278
ASTM-A395 DI, 316 SS screen,
0.057 diam perforated screen
Mueller No 761

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


H

ZAB

ASTM-A395, w/Monel
screen

ASTM-A395 DI, Monel screen,


0.057 diam perforated screen
Mueller

ZAC

ASTM-A395, w/SS
screen

ASTM-A395, ductile iron,


galvanized, 0.045 SS screen
Mueller 251-DI

ZAD

ASTM-A395, w/SS
screen

ASTM-A395, ductile iron,


galvanized, 100 mesh SS screen,
Mueller 251-DI

ZAE

ASTM-A395, w/SS
screen

ASTM-A395, ductile iron,


galvanized, 0.045 SS screen
Mueller 751-DI

Instrument Specialties
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: I - INSTRUMENT SPECIALTIES (PDS WILL NOT USE)
I AA

Air selector

Air selector

I AD

adapter

adapter

I AE

Reducing adapter Reducing adapter

I AJ

Syphon

Syphon

I BA

Banding kit

Banding kit

I BJ

Junction box

Junction box

I BO

Heated enclosure Heated enclosure

I BP

Pipe clamp

Pipe clamp

I BR

Pipe hex nipple

Pipe nex nipple

I CB

Machine bolt

Machine bolt

I CN

Nut

Nut, w/spring

I CP

Push clips

Push clips

I CR

Expansion anchor Expansion anchor

I CS

Split washer

Split washer

I CT

Threaded rod

Threaded rod

I CU

Machine screw

Flat head machine screw

I DA

Dampener

Pulsation dampener

I EA

Splice

Splice

I FF

Filter, tee type Filter, tee type

Plant Design System (PDS) Piping Component Data

465

Commodity Code Descriptions

466

I FR

Filter regulator Filter regulator

I GM

Gauge mounting
kit

Gauge mounting kit

I GP

Pressure gauge

Pressure gauge

I GR

Receiver gauge

Receiver gauge

I HC

Conduit clamp

Heavy duty conduit clamp

I LA

Ladder tray

Ladder tray

I LB

Channel

Channel

I LC

Cover

Cover

I LD

Dropout

Dropout

I LE

Expansion
connector

Expansion connector

I LF

Flat connector

Flat connector, w/5% extra bolts &


nuts DS-8530-1/DS-8524-1

I LG

Reducer
Reducer connector offset
connector offset

I LH

Hold down clip,


w/guide

Hold down clip, w/guide

I LL

Elbow 90 deg

Elbow 90 deg

I LR

Reducer

Reducer

I LT

Tee

Tee

I MA

Air manifold

Air manifold

I OR

Restriction
orifice

Restriction orifice

I PC

Cond pot

Condensate pot

I PD

Drip pot,
w/mounting tab

Drip pot, w/mounting tab

I PP

Seal patch

Seal patch

I PS

Seal pot

Seal pot

I RA

Air relay

Air relay

I RB

Booster relay

Booster relay

I RG

O ring gasket

O ring gasket

I RO

Rotometer

Rotometer

I RR

Relay

Relay

I SC

Column mount
support

Column mount support

I SF

Floor mount
support

Floor mount support

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


I SL

Line mount
support

Line mount support

I SO

Off-platform
mount Support

Off-platform mount support

I SP

Platform mount
support

Platform mount support

I SS

Surface mount
support

Surface mount support

I SW

Wall mount
support

Wall mount support

I UA

Packing gland

Packing gland

I VA

Vert adapter

Vertical adapter

I WR

Raceway,
w/connector

Raceway, w/connector & 5% extra


drive rivets

I YA

Vent plug

Vent plug

I YB

Bugproof vent

Bugproof vent

I ZZ

single pipe mount single pipe instr mount

single mount

double pipe mount double pipe instr mount

double mount, w/1 double instr mount, w/1 plate


plate

double mount, w/1 double instr mount, w/1 pipe & 1


pipe & 1 plate
plate

triple mount, w/2 triple instr mount, w/2 pipe & 1


pipe & 1 plate
plate

single angle
mount

single angle mount

horizontal

horizontal for ladder tray


fittings

double angle
mount

double angle mount

100 band, w/100 100 band, w/100 clips


clips

double mount, w/1 double mount, w/1 pipe & 1 angle


pipe & 1 angle

double mount

triple mount, w/1 triple instr mount, w/1 pipe & 1


pipe & 1 plate
plate

single instr mount

double mount

Plant Design System (PDS) Piping Component Data

467

Commodity Code Descriptions


I

panel, w/angle
legs

panel, w/angle legs

std

standard

vertical

vertical for ladder tray fittings

angled

angled

inside

inside

outside

outside

straight

straight

w/air header

w/air header

w/o air header

w/o air header

CA

clamped

clamped

CB

cabled

cables

CC

welded

welded

CD

bolted

bolted

CE

U-bolt

U-bolt

FA

flanged

flanged

SW

SW

socketwelded

TA

THD

threaded

TF

FTE

female pipe thread

TG

FTE x red MTE

female pipe thread x reducing male


pipe thread

TL

MTE back conn

male pipe thread back connection

TM

MTE

male pipe thread

TN

MTE bottom conn

male pipe thread bottom connection

TS

male SW x FTE

male socketwelded x female pipe


thread

TT

tube x tube

tube x tube

TX

MTE x FTE

male x female pipe thread

WB

BW

buttwelded

ZZ

468

AAA

carbon steel

carbon steel

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


I

AAC

CS

CS AISI-1018, Hex 10025-002 thru


10030-002

AAD

CS

CS, w/303 SS inner tubes,


Anderson-Greenwood CT7-44

AAE

AISI-C1018

AISI-C1018, barstock, Cajon Series


RA

AAF

AISI-C1018

AISI-C1018, barstock, Cajon


S-MPW-7

AAH

ASTM-A106-B

ASTM-A106 Gr.B, w/1/16 eccentricity

AAI

ASTM-A106-B

ASTM-A106 Gr.B, Shirlee Ind


2090-1000

AAJ

CS

CS, Shirlee Ind 3100-5000

AAK

CS

CS, Shirlee Ind 3101-5000

AAL

CS

CS, Shirlee Ind 3101-2500-1

AAM

ASME-SA105,
SA106-B

ASME-SA105, SA106-B, Shirlee Ind


3101-5000

AAN

ASTM-A106-B,
S-80

ASTM-A106 Gr.B, S-80, Shirlee Ind


2090-2500-1

AAO

ASTM-A106-B

ASTM-A106 Gr.B, Shirlee Ind


35.51-2500

AAP

ASTM-A106-B

ASTM-A106 Gr.B, Shirlee Ind


3101-2500

AAQ

CS

CS, Unistrut P-3300

AAR

CS

CS, galvanized Unistrut P-2033

AAS

CS

CS, galvanized Unistrut P-2037

AAT

CS

CS, galvanized Unistrut P-2024

AAU

CS

CS, galvanized Unistrut P-2025

AAV

CS

CS, galvanized Unistrut P-2026

AAW

CS

CS, galvanized Unistrut P-1000 HS

AAX

CS

CS, electro galvanized, w/spring


Unistrut P-1010

AAY

CS

CS, electro galvanized Unistrut


HFMS050100EG

ABA

ASTM-A106-B

ASTM-A106 Gr.B, Det XAA

ABB

CS

CS, Det MHA

ABC

CS

CS, Det MDA & MEA

ABD

CS

CS, Det MIA

ABE

CS

CS, Det MFB

ABF

CS

CS, Det MAA & MAC

Plant Design System (PDS) Piping Component Data

469

Commodity Code Descriptions


I

ABG

CS

CS, Det MAB & MAD

ABH

CS

CS, Det MDB & MEB

ABI

CS

CS, Det MFA

ABJ

CS

CS, Det MGA

ABK

CS

CS, Det MGB

ABL

CS

CS, Det MHB

ABN

CS

CS, Det MDG & MEG

ABO

CS

CS, Det MDH & MEH

ABP

CS

CS, Det MDF & MEF

ABQ

CS

CS, Det MHG

ABR

CS

CS, Det MHF

ABS

CS

CS, Det MHH

ABT

CS

CS, Det MFF

ABU

CS

CS, Det MFG

ABV

CS

CS, Det MCA

ABW

CS

CS, Det MCB

ABX

CS

CS, Det MBA

ABY

CS

CS, Det MBB

ABZ

CS

CS, Det MJA THRU MJK

ACA

CS

CS, Det MAE & MAG

ACB

CS

CS, Det MAF & MAH

ACC

CS

CS, Det MBC

ACD

CS

CS, Det MBD

ACE

CS

CS, Det MCC

ACF

CS

CS, Det MCD

ACG

CS

CS, Det MAI & MAJ

ACH

CS

CS, Det MAK & MAL

ACI

CS

CS, Det MBE

CS

CS, Det MBF

ACJ

470

ACK

CS

CS, Det MCE

ACL

CS

CS, Det MCF

ACM

CS

CS, Det MJX

ACN

CS

CS, Det MJY

ACO

CS

CS, Det MJZ

ACP

CS

CS, Det MKA

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


I

ACQ

CS

CS, Det MKB

ACR

CS

CS, Det MIB

ACS

CS

CS, Det MHI

ACT

CS

CS, Det MIC

ACU

CS

CS, Det MID

ACV

CS

CS, Det MDI

ACW

CS

CS, Det MKF

ACX

CS

CS, Det MHC

ADA

CS

CS, Det MLA

ADB

CS

CS, Det MLB

ADC

CS

CS, Det MLC

ADD

CS

CS, Det MLD

ADE

CS

CS, Det MLE

ADF

CS

CS, Det MLF

ADG

CS

CS, Det MLG

ADH

CS

CS, Det MLH

ADI

CS

CS, Det MLI

ADJ

CS

CS, Det MLJ

ADK

CS

CS, Det MLK

ADL

CS

CS, Det MLL

ADM

CS

CS, Det MLM

ADN

CS

CS, Det MDJ

ADO

CS

CS, Det MBG

ADP

CS

CS, Det MBH

ADQ

CS

CS, Det MCG

ADR

CS

CS, Det MDC

ADS

CS

CS, Det MDD

ADT

CS

CS, Det MDE

ADV

CS

CS, Det MIE

ADW

CS

CS, Det MHD

ADX

CS

CS, Det MHE

ADY

CS

CS, Det MIF

ADZ

CS

CS, Det MIG

AEB

CS

CS, Det MIH

AEC

CS

CS, Det MOG

Plant Design System (PDS) Piping Component Data

471

Commodity Code Descriptions

472

AED

CS

CS, Det MPG

AEE

CS

CS, Det MFJ

AEF

CS

CS, Minerallac H75

AEG

CS

CS, Det MDK

AZZ

matl unspec

no matl specified

CAA

CS

CS, P-W Ind 18-1442-0024-(Size-1)


or approved equal

CAB

CS

CS, P-W Ind 1442-1302-02 or approved


equal

CAC

CS

CS, P-W Ind 1442-1314-02 or approved


equal

CAD

CS

CS, P-W Ind 18-1442-9012-(Size-1)


Series 2 or approved equal

CAE

CS

CS, P-W Ind 18-1442-9112-(Size-1)


Series 2 or approved equal

CAF

CS

CS, P-W Ind


1442-01-(Size-1)-(Size-2) or
approved equal

CAG

CS

CS, P-W Ind 1442-9212-(Size-1) or


approved equal

CAH

CS

CS, P-W Ind 1442-2012-(Size-1) or


approved equal

CAI

CS

CS, P-W Ind 9987-0249-(Size-1) or


approved equal

CAJ

CS

CS, P-W Ind 1508-0012-04 or approved


equal

CAK

CS

CS, P-W Ind 1508-1301-04 or approved


equal

CAL

CS

CS pre-galvanized steel, P-W Ind


2501-0016-(Size 1)-1301 & DS-8500-01
or approved equal

CAM

SS

TP304 SS, P-W Ind DS-9004-(Size 1)


or approved equal

CAN

CS

CS, P-W Ind 9985-1893-01, w/bolt,


nut & lockwasher or approved equal

CAO

CS

CS, P-W Ind 1442-1304-(Size 1) or


approved equal

CAP

CS

CS, P-W Ind 9985-1893-01,


w/carriage bolt & std spring

EAB

ASTM-A335-P11

ASTM-A335 Gr.P11, 1.25Cr, Det XAB

FAA

316 SS FILTER

316 SS filter, Nupro SS-(Size


1)-TF-7

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


I

IAA

stainless steel

stainless steel

IAB

SS

316 SS ASTM-A479 TP316, Hex


10025-002 thru 10030-002

IAC

316 SS

316 SS

IAF

316 SS

316 SS, Hex HK111U24 no equal

IAG

SS

SS, P-W Ind 9996-0904-01 or approved


equal

IAH

316 SS

316 SS, Cajon SS-4-RA-2

IAI

316 SS

316 SS, Mid-West 150SH

IAJ

316 SS

316 SS, w/316 SS inner & outer tube,


Anderson-Greenwood CT7S-44

IBB

SS

316 SS, Ashcroft 1009 or approved


equal

IBC

SS

316 SS, Ashcroft 1008S or approved


equal

IBD

SS

316 SS, Ashcroft 1008A or approved


equal

IIH

ASTM-A312-304

ASTM-A312 Type 304, w/1/16


eccentricity

IIJ

ASTM-A479-316

ASTM-A479 Type 316, barstock, Cajon


MPW-A-IPS

IIK

ASTM-A479-316

ASTM-A479 Type 316, barstock, Cajon


Series RA

IIL

304 SS

304 SS, Shirlee Ind 3100-6500-304

IIM

304 SS

304 SS, Shirlee Ind 3101-6500-304

IIN

ASTM-A312-304

ASTM-A312 Type 304, Shirlee Ind


2090-2500-1-304

IIO

ASTM-A312-304

ASTM-A312 Type 304, Shirlee Ind


35.53-2500-304

IIP

ASTM-A312-304

ASTM-A312 Type 304, Shirlee Ind


3101-2500-304

IIQ

ASTM-A312-304

ASTM-A312 Type 304, Shirlee Ind


2090-5000-1-304

IIR

ASTM-A312-304

ASTM-A312 Type 304, Shirlee Ind


35.51-5000-304

IIS

ASTM-A312-304

ASTM-A312 Type 304, Shirlee Ind


3101-5000-304

NAA

bronze

bronze

NAB

brass

brass ASTM-B16, Hex 10025-002 thru


10030-002

NAC

brass

brass, Fisher P-594-1

Plant Design System (PDS) Piping Component Data

473

Commodity Code Descriptions

474

RAA

die cast zinc

die cast zinc, Fisher Y602-7, -13

SAA

aluminum

aluminum

SBB

die cast aluminum die cast aluminum, Masoneilan 77-40


or approved equal

SBC

die cast aluminum die cast aluminum, Masoneilan 77-4


or approved equal

SBD

die cast aluminum die cast aluminum, Yokogawa


Hokushin Electric #T44A

SCA

aluminum allloy

aluminum alloy 6063-T6, P-W


Industries 09-4F14-0024-(Size 1)

SCB

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 4F14-1302-02

SCC

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 9998-0249-(Size 1)

SCD

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 4F14-1314-02

SCE

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 09-4F14-9012-(Size 1) Ser
2

SCF

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 09-4F14-9112-(Size 1) Ser
2

SCG

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 09-4F14-9212-(Size 1) Ser
2

SCI

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 09-4F14-2012-(Size 1) Ser
2

SCJ

aluminum alloy

aluminum alloy 6063-T6, P-W


Industries 5501-0016-(Size 1)

TAA

Teflon

Teflon, Rosemount O1151-0035-0003


or approved equal

TAB

Viton

Viton, Rosemount 01151-0035-0001 or


approved equal

TAC

Thermoplastic

Thermoplastic, Dekoron 1540-10000


or approved equal

XXX

matl per reqn

matl per specification ??

ZAB

cast iron

cast iron, Fisher 254

ZAC

ASTM-A126

ASTM-A126 cast iron, Varec 42S

ZZZ

no matl reqd

no matl required for this detail

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions

Pipe Supports
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: J - PIPE SUPPORTS (PDS WILL NOT USE)
J BA

NA base support

Base support non-adjustable

J BB

ADJ base support

Base support adjustable

J BC

Welded beam attach

Welded beam attachment

J BD

Rigid base support

Base support rigid

J BE

Bolt-on base support

Bolt-on base support

J BF

Bolt-on base spring


support

Bolt-on base spring support

J BG

Base support, w/slide Bolt-on base support,


plate
w/slide plate

J BH

NA base support,
w/slide plate

Base support, w/slide plate

J BR

Bracket

Bracket

J BS

Base spring support

Base spring support

J CA

Hvy 2-bolt clamp

Heavy 2 bolt clamp

J CB

Hvy 3-bolt clamp

Heavy 3 bolt clamp

J CC

Adj clevis

Adjustable clevis hanger

J CD

Pipe clamp

Pipe clamp

J CE

3-bolt pipe clamp

3 bolt pipe clamp

J CR

Riser clamp

Riser clamp

J DA

Dummy support

Dummy extension support

J EA

Fastener

Fastener

J EB

U-bolt, w/nuts

U-bolt, w/4 nuts

J EC

Weldless eye nut

Weldless eye nut

J ED

Welded eye rod

Welded eye rod

J FA

Pipe lug

Pipe lug

J FB

Beam

Beam

J FC

Trapeze

Trapeze

J FD

Vert beam support

Vertical beam support

J FE

Stabilizer

Stabilizer

J FF

Horiz beam support

Horizontal beam support

J FG

Pick-up support

Pick-up support

Plant Design System (PDS) Piping Component Data

475

Commodity Code Descriptions


J FH

Welding lug

Welding lug

J FI

Frame support

Frame support

J FS

Flexible strut

Flexible strut

J GA

Vibration pipe clamp

Vibration pipe clamp

J HA

Hanger rod assem

Pipe hanger rod assembly

J IS

Instr support

Instrument support

J PA

Pipe anchor

Pipe anchor

J PB

Pipe anchor & guide

Pipe andhor & guide

J PC

Bolt-on shoe

Bolt-on pipe shoe

J PD

Bolt-on shoe & guide

Bolt-on shoe & guide

J PE

Bolt-on shoe anchor

Bolt-on shoe anchor

J PG

Pipe guide

Pipe guide

J PH

Pipe shoe, w/slide

Pipe shoe, w/slide bearing

J PI

Insul pipe support


saddle

Insulated pipe support


saddle

J PJ

Pipe shoe, w/guides

Pipe shoe, w/guides

J PK

Pipe protection
saddle

Pipe covering protection


saddle

J PP

Pipe support pad

Pipe support pad

J PS

Pipe shoe

Pipe shoe

J RA

Rod

Rod

J RB

Threaded rod

Threaded rod

J RC

THD rod, both ends

Threaded rod, both ends

J SB

Sway brace

Sway brace

J SH

Spring hanger

Spring hanger

J SM

Structural member

Structural member

J SP

Slide

Slide

J SS

Structural shape

Structural shape

J VA

Vessel bracket

Pipe bracket for vertical


Vessel

J VG

Vessel guide

Vessel pipe guide

J VH

Bolt-on vessel guide

Bolt-on vessel guide

J VL

Vessel lugs

Pipe lugs for vessel bracket

J VS

Snubber

Snubber

J ZZ

476

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


J

Heat or uninsulated

Heat insulated or
uninsulated

Cold or uninsulated

Cold insulated or
uninsulated

Cold insulated

Cold insulated

Cold insul single


layer

Cold insulated single layer

Cold insul double


layer

Cold insulated double layer

Heat insulated

Heat insulated

Dual purp, single


layer

Dual purpose, single layer

Dual purp, double


layer

Dual purpose, double layer

Uninsulated

Uninsulated

Plate

Plate

Flat bar

Flat bar

Angle

Angle

Channel

Channel

I-beam

I-beam

Wide flange

Wide flange

ST structural tee

ST structural tee

Tube

Tube

Attach to conc beam

Attach to concrete beam

Attach to conc col

Attach to conc column

Attach to steel

Attachment to steel

2 "

2 "

3 "

3 "

4 "

4 "

5 "

5 "

6 "

6 "

Plant Design System (PDS) Piping Component Data

477

Commodity Code Descriptions

478

7 "

7 "

8 "

8 "

50 mm

50 mm

75 mm

75 mm

100 mm

100 mm

125 mm

125 mm

150 mm

150 mm

175 mm

175 mm

200 mm

200 mm

height per reqn

height per specification ??

AA

CS Spec 400-303-1

CS per Specification
400-303, Det 1

AAB

CS Spec 400-303-2

CS per Specification
400-303, Det 2

AAC

CS Spec 400-303-3

CS per Specification
400-303, Det 3

AAD

CS Spec 400-303-4

CS per Specification
400-303, Det 4

AAE

CS Spec 400-303-1A

CS per Specification
400-303, Det 1A

ACA

CS Spec 400-306-2

CS per Specification
400-306, Det 2

ACB

CS Spec 400-306-1

CS per Specification
400-306, Det 1

ACC

CS Spec 400-307-1A

CS per Specification
400-307, Det 1A

ACD

CS Spec 400-306-4

CS per Specification
400-306, Det 4

ACE

CS Spec 400-306-6

CS per Specification
400-306, Det 6

ACF

CS Spec 400-307-2A

CS per Specification
400-307, Det 2A

ACG

CS Spec 400-306-8

CS per Specification
400-306, Det 8

ACH

CS Spec 400-306-7

CS per Specification
400-306, Det 7

ACI

CS Spec 400-307-3A

CS per Specification
400-307, Det 3A

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


J

ACK

CS Spec 400-306-5

CS per Specification
400-306, Det 5

ACM

CS Spec 400-306-3

CS per Specification
400-306, Det 3

ACN

CS Spec 400-306-9

CS per Specification
400-306, Det 9

ADA

CS Spec 400-312-7

CS per Specification
400-312, Det 7

ADD

CS Spec 400-312-6

CS per Specification
400-312, Det 6

AEW

CS Spec 400-307-13

CS per Specification
400-307, Det 13

AFA

CS Spec 400-323-76,
78, 80

CS per Specification
400-323, Det 76, 78, 80

AFB

CS Spec 400-323-82

CS per Specification
400-323, Det 82

AFG

CS Spec 400-323-6, 8, CS per Specification


10
400-323, Det 6, 8, 10

AFH

CS Spec 400-323-12

CS per Specification
400-323, Det 12

AHA

CS Spec 400-304-1

CS per Specification
400-304, Det 1

AHB

CS Spec 400-304-2

CS per Specification
400-304, Det 2

AHC

CS Spec 400-304-3

CS per Specification
400-304, Det 3

AHD

CS Spec 400-304-4

CS per Specification
400-304, Det 4

AHE

CS Spec 400-304-5

CS per Specification
400-304, Det 5

AHF

CS Spec 400-304-8

CS per Specification
400-304, Det 8

AHG

CS Spec 400-304-11

CS per Specification
400-304, Det 11

AHH

CS Spec 400-304-13

CS per Specification
400-304, Det 13

AHI

CS Spec 400-304-14

CS per Specification
400-304, Det 14

AHJ

CS Spec 400-304-15

CS per Specification
400-304, Det 15

AHK

CS Spec 400-304-17

CS per Specification
400-304, Det 17

Plant Design System (PDS) Piping Component Data

479

Commodity Code Descriptions

480

AHL

CS Spec 400-304-21

CS per Specification
400-304, Det 21

AHM

CS Spec 400-304-22

CS per Specification
400-304, Det 22

AHN

CS Spec 400-304-23

CS per Specification
400-304, Det 23

AHO

CS Spec 400-304-25

CS per Specification
400-304, Det 25

AHP

CS Spec 400-304-27

CS per Specification
400-304, Det 27

AHQ

CS Spec 400-304-28

CS per Specification
400-304, Det 28

AHR

CS Spec 400-304-29

CS per Specification
400-304, Det 29

AHS

CS Spec 400-304-31

CS per Specification
400-304, Det 31

AHU

CS Spec 400-304-33

CS per Specification
400-304, Det 33

AHV

CS Spec 400-304-34

CS per Specification
400-304, Det 34

AHW

CS Spec 400-304-36

CS per Specification
400-304, Det 36

AHX

CS Spec 400-304-37

CS per Specification
400-304, Det 37

AHY

CS Spec 400-304-16

CS per Specification
400-304, Det 16

AHZ

CS Spec 400-304-18

CS per Specification
400-304, Det 18

BEL

CS Spec 400-307-22

CS per Specification
400-307, Det 22

BEM

CS Spec 400-307-23

CS per Specification
400-307, Det 23

BEN

CS Spec 400-307-24

CS per Specification
400-307, Det 24

BEO

CS Spec 400-307-25

CS per Specification
400-307, Det 25

BEP

CS Spec 400-307-26

CS per Specification
400-307, Det 26

BHA

CS Spec 400-304-20

CS per Specification
400-304, Det 20

BHB

CS Spec 400-304-24

CS per Specification
400-304, Det 24

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


J

CAA

ASTM-A516-65

ASTM-A516 Gr.65

CAC

ASTM-A307-A

ASTM-A307 Gr.A, w/4


assembled nuts

CAD

ASTM-A36

ASTM-A36

CAE

ASTM-A105

ASTM-A105

CAG

ASTM-A36

ASTM-A36, Grinnell Fig 162

CAH

CS

CS, Grinnell Fig 140,


w/tensile strength per Cat
PH83

FAA

Cr Spec 400-303-1

chrome steel per


Specification 400-303, Det 1

FAB

Cr Spec 400-303-2

chrome steel per


Specification 400-303, Det 2

FAC

Cr Spec 400-303-3

chrome steel per


Specification 400-303, Det 3

FAD

Cr Spec 400-303-4

chrome steel per


Specification 400-303, Det 4

FAE

Cr Spec 400-303-1A

chrome steel per


Specification 400-303, Det
1A

FCA

Cr Spec 400-306-2

chrome steel per


Specification 400-306, Det 2

FCB

Cr Spec 400-306-1

chrome steel per


Specification 400-306, Det 1

FCC

Cr Spec 400-307-1A

chrome steel per


Specification 400-307, Det
1A

FCD

Cr Spec 400-306-4

chrome steel per


Specification 400-306, Det 4

FCE

Cr Spec 400-306-6

chrome steel per


Specification 400-306, Det 6

FCF

Cr Spec 400-307-2A

chrome steel per


Specification 400-307, Det
2A

FCG

Cr Spec 400-306-8

chrome steel per


Specification 400-306, Det 8

FCH

Cr Spec 400-306-7

chrome steel per


Specification 400-306, Det 7

FCI

Cr Spec 400-307-3A

chrome steel per


Specification 400-307, Det
3A

FCK

Cr Spec 400-306-5

chrome steel per


Specification 400-306, Det 5

Plant Design System (PDS) Piping Component Data

481

Commodity Code Descriptions

482

FCM

Cr Spec 400-306-3

chrome steel per


Specification 400-306, Det 3

FCN

Cr Spec 400-306-9

chrome steel per


Specification 400-306, Det 9

FDA

Cr Spec 400-312-7

chrome steel per


Specification 400-312, Det 7

FDD

Cr Spec 400-312-6

chrome steel per


Specification 400-312, Det 6

FEW

Cr Spec 400-307-13

chrome steel per


Specification 400-307, Det
13

FHA

Cr Spec 400-304-4

chrome steel per


Specification 400-304, Det 4

FHB

Cr Spec 400-304-6

chrome steel per


Specification 400-304, Det 6

FHC

Cr Spec 400-304-9

chrome steel per


Specification 400-304, Det 9

FHD

Cr Spec 400-304-12

chrome steel per


Specification 400-304, Det
12

FHE

Cr Spec 400-304-15

chrome steel per


Specification 400-304, Det
15

FHF

Cr Spec 400-304-16

chrome steel per


Specification 400-304, Det
16

FHG

Cr Spec 400-304-17

chrome steel per


Specification 400-304, Det
17

FHH

Cr Spec 400-304-18

chrome steel per


Specification 400-304, Det
18

FHI

Cr Spec 400-304-23

chrome steel per


Specification 400-304, Det
23

FHJ

Cr Spec 400-304-24

chrome steel per


Specification 400-304, Det
24

FHK

Cr Spec 400-304-25

chrome steel per


Specification 400-304, Det
25

FHL

Cr Spec 400-304-26

chrome steel per


Specification 400-304, Det
26

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


J

FHM

Cr Spec 400-304-11

chrome steel per


Specification 400-304, Det
11

FHN

Cr Spec 400-304-13

chrome steel per


Specification 400-304, Det
13

GAA

ASTM-A387-11

ASTM-A387 Gr.11, 1.25Cr

GAB

ASTM-A387-22

ASTM-A387 Gr.22, 2.25Cr

GAC

ASTM-A193-B7

ASTM-A193 Gr.B7, w/4


assembled ASTM-A194 Gr.2H
nuts

IAA

SS Spec 400-303-1

SS per Specification
400-303, Det 1

IAB

SS Spec 400-303-2

SS per Specification
400-303, Det 2

IAC

SS Spec 400-303-3

SS per Specification
400-303, Det 3

IAD

SS Spec 400-303-4

SS per Specification
400-303, Det 4

IAE

SS Spec 400-303-1A

SS per Specification
400-303, Det 1A

ICA

SS Spec 400-306-2

SS per Specification
400-306, Det 2

ICB

SS Spec 400-306-1

SS per Specification
400-306, Det 1

ICD

SS Spec 400-306-4

SS per Specification
400-306, Det 4

ICE

SS Spec 400-306-6

SS per Specification
400-306, Det 6

ICG

SS Spec 400-306-8

SS per Specification
400-306, Det 8

ICH

SS Spec 400-306-7

SS per Specification
400-306, Det 7

ICK

SS Spec 400-306-5

SS per Specification
400-306, Det 5

ICM

SS Spec 400-306-3

SS per Specification
400-306, Det 3

ICN

SS Spec 400-306-9

SS per Specification
400-306, Det 9

ICO

SS Spec 400-306-10

SS per Specification
400-306, Det 10

IDA

SS Spec 400-312-7

SS per Specification
400-312, Det 7

Plant Design System (PDS) Piping Component Data

483

Commodity Code Descriptions

484

IDD

SS Spec 400-312-6

SS per Specification
400-312, Det 6

IEW

SS Spec 400-307-13

SS per Specification
400-307, Det 13

IFA

SS Spec 400-323-76,
78, 80

SS per Specification
400-323, Det 76, 78, 80

IFB

SS Spec 400-323-82

SS per Specification
400-323, Det 82

IFC

SS Spec 400-323-96,
98, 100

SS per Specification
400-323, Det 96, 98, 100

IFD

SS Spec 400-323-102

SS per Specification
400-323, Det 102

IFG

SS Spec 400-323-6, 8, SS per Specification


10
400-323, Det 6, 8, 10

IFH

SS Spec 400-323-12

SS per Specification
400-323, Det 12

IHA

SS Spec 400-304-4

SS per Specification
400-304, Det 4

IHB

SS Spec 400-304-7

SS per Specification
400-304, Det 7

IHC

SS Spec 400-304-10

SS per Specification
400-304, Det 10

IHD

SS Spec 400-304-12

SS per Specification
400-304, Det 12

IHE

SS Spec 400-304-15

SS per Specification
400-304, Det 15

IHF

SS Spec 400-304-16

SS per Specification
400-304, Det 16

IHG

SS Spec 400-304-17

SS per Specification
400-304, Det 17

IHH

SS Spec 400-304-18

SS per Specification
400-304, Det 18

IHI

SS Spec 400-304-23

SS per Specification
400-304, Det 23

IHJ

SS Spec 400-304-24

SS per Specification
400-304, Det 24

IHK

SS Spec 400-304-25

SS per Specification
400-304, Det 25

IHL

SS Spec 400-304-26

SS per Specification
400-304, Det 26

IHM

SS Spec 400-304-11

SS per Specification
400-304, Det 11

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


J

IHN

SS Spec 400-304-13

SS per Specification
400-304, Det 13

IHO

SS Spec 400-304-14

SS per Specification
400-304, Det 14

IHP

SS Spec 400-304-21

SS per Specification
400-304, Det 21

IHQ

SS Spec 400-304-33

SS per Specification
400-304, Det 33

IHR

SS Spec 400-304-34

SS per Specification
400-304, Det 34

IHS

SS Spec 400-304-35

SS per Specification
400-304, Det 35

IHT

SS Spec 400-304-36

SS per Specification
400-304, Det 36

IHU

SS Spec 400-304-37

SS per Specification
400-304, Det 37

IHV

SS Spec 400-304-38

SS per Specification
400-304, Det 38

IHW

SS Spec 400-304-39

SS per Specification
400-304, Det 39

IHX

SS Spec 400-304-20

SS per Specification
400-304, Det 20

IHY

SS Spec 400-304-22

SS per Specification
400-304, Det 22

TAA

rigid polyurethane
foam

rigid polyurethane foam,


w/vapor barrier, Power Piping
Powerfoam 9104

TAB

rigid polyurethane
foam

rigid polyurethane foam,


w/vapor barrier, Power Piping
Powerfoam 9105

THS

graphite 400-304-30

graphite per Specification


400-304, Det 30

TZA

high-density Ca
silicate

high-density calcium
silicate, w/vap barrier,
Power Piping HI-TEMP 9238

XAE

Spec 400-303-6

see specification 400-303,


Det 6

XAF

Spec 400-303-7

see specification 400-303,


Det 7

XAG

Spec 400-303-8

see specification 400-303,


Det 8

XAH

Spec 400-303-9

see specification 400-303,


Det 9

Plant Design System (PDS) Piping Component Data

485

Commodity Code Descriptions

486

XAI

Spec 400-303-10

see specification 400-303,


Det 10

XAJ

Spec 400-303-11

see specification 400-303,


Det 11

XAK

Spec 400-303-12

see specification 400-303,


Det 12

XAL

Spec 400-303-13

see specification 400-303,


Det 13

XAM

Spec 400-303-14

see specification 400-303,


Det 14

XAN

Spec 400-303-12B

see specification 400-303,


Det 12B

XDA

Spec 400-312-1, 2, 3, see specification 400-312,


4, 5
Det 1, 2, 3, 4, 5

XEA

Spec 400-307-1

see specification 400-307,


Det 1

XEB

Spec 400-307-2

see specification 400-307,


Det 2

XEC

Spec 400-307-3

see specification 400-307,


Det 3

XED

Spec 400-307-4

see specification 400-307,


Det 4

XEE

Spec 400-307-5

see specification 400-307,


Det 5

XEF

Spec 400-307-6

see specification 400-307,


Det 6

XEG

Spec 400-307-7

see specification 400-307,


Det 7

XEH

Spec 400-307-8

see specification 400-307,


Det 8

XEI

Spec 400-307-9

see specification 400-307,


Det 9

XEJ

Spec 400-307-10

see specification 400-307,


Det 10

XEK

Spec 400-307-11

see specification 400-307,


Det 11

XEL

Spec 400-307-12

see specification 400-307,


Det 12

XEM

Spec 400-307-14

see specification 400-307,


Det 14

XEN

Spec 400-307-15

see specification 400-307,


Det 15

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


J

XEO

Spec 400-307-16

see specification 400-307,


Det 16

XEP

Spec 400-307-17

see specification 400-307,


Det 17

XEQ

Spec 400-307-18

see specification 400-307,


Det 18

XER

Spec 400-307-19

see specification 400-307,


Det 19

XES

Spec 400-307-4A

see specification 400-307,


Det 4A

XET

Spec 400-307-7A

see specification 400-307,


Det 7A

XEU

Spec 400-307-15A

see specification 400-307,


Det 15A

XFA

Spec 400-323-1, 2, 3

see specification 400-323,


Det 1, 2, 3

XFB

Spec 400-323-14, 16,


18

see specification 400-323,


Det 14, 16, 18

XFC

Spec 400-323-19, 20,


21, 22, 23

see specification 400-323,


Det 19, 20, 21, 22, 23

XFG

Spec 400-323-4

see specification 400-323,


Det 4

XFI

Spec 400-323-31, 32,


33

see specification 400-323,


Det 31, 32, 33

XFJ

Spec 400-323-34

see specification 400-323,


Det 34

XFK

Spec 400-323-41, 42,


43

see specification 400-323,


Det 41, 42, 43

XFL

Spec 400-323-44

see specification 400-323,


Det 44

XFM

Spec 400-323-54, 56,


58

see specification 400-323,


Det 54, 56, 58

XFN

Spec 400-323-64, 66,


68

see specification 400-323,


Det 64, 66, 68

XGA

Spec 400-314-1

see specification 400-314,


Det 1

XGB

Spec 400-314-2

see specification 400-314,


Det 2

XGC

Spec 400-314-3

see specification 400-314,


Det 3

XGD

Spec 400-314-4

see specification 400-314,


Det 4

Plant Design System (PDS) Piping Component Data

487

Commodity Code Descriptions


J

XHA

Spec 400-304-19

see specification 400-304,


Det 19

XHB

Spec 400-304-20

see specification 400-304,


Det 20

XHC

Spec 400-304-1

see specification 400-304,


Det 1

XHD

Spec 400-304-2

see specification 400-304,


Det 2

XHE

Spec 400-304-3

see specification 400-304,


Det 3

XHF

Spec 400-304-26

see specification 400-304,


Det 26

XHG

Spec 400-304-27

see specification 400-304,


Det 27

XHH

Spec 400-304-28

see specification 400-304,


Det 28

XIA

Spec 464-56-PSC

see specification 464-56,


Type PSC

XXX

Labor Codes
L
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: L - LABOR CODES (PDS WILL NOT USE)

488

L BA

Bend (1-45 deg)

L BB

Bend (46-90 deg)

L
L
L
L

MA
PA
PB
PC

Miter elbow
Pipe cut
Pipe bevel
Pipe J-bevel

L PD
L PE

Pipe weld
Preheat weld

L PW

Pipe weld w/PWHT

L RA

Stress rel weld

L RB

Stress rel spool

Labor for bend 1-45


deg
Labor for bend 46-90
deg
Labor for miter elbow
Labor for pipe cut
Labor for pipe bevel
Labor for pipe
J-bevel
Labor for pipe weld
Labor for pipe
preheating prior to
welding
Labor for pipe weld
requiring post weld
heat treatment
Labor for stress
relieving weld
Labor for stress

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions

L SA

Unreinforced stub in

L SB

Weld reinf stub in

L SC

Pad reinf stub in

L SP

Weld reinf stub in


w/PWHT

L TA

Liq pen test weld

L TB

Impact test weld

L TC

Mag part test weld

L TD

X-ray test 1-shot weld

L TE

X-ray test 2-shot weld

L
L
L
L
L
L
L
L
L
L
L
L
L
L

Z
BZ
CZ
DZ
GZ
HZ
IZ
JZ
KZ
NZ
OZ
PZ
QZ
TZ

3-diam
4-diam
5-diam
6-diam
1-cut
2-cut
3-cut
4-cut
5-cut
90 deg
60 deg
45 deg
30 deg
WOL/hdr weld

L
L
L
L
L
L

WZ
XZ
YZ
ZZ
AA
AB

BW
fillet weld
SW
S-5S
S-10S

relieving pipespool
Labor for unreinforced
stub in branch
Labor for weld
reinforced stub in
branch
Labor for pad
reinforced stub in
branch
Labor for weld reinf
stub in branch
requiring post weld
heat treatment
Labor for testing weld
by liquid penetrant
method
Labor for testing weld
by impact method
Labor for testing weld
by magnetic particle
method
Labor for testing weld
by radiography (1
shot)
Labor for testing weld
by radiography (2
shot)
3-diam
4-diam
5-diam
6-diam
1-cut
2-cut
3-cut
4-cut
5-cut
90 deg
60 deg
45 deg
30 deg
weldolet to header
weld
buttwelded
fillet weld
socketwelded

Sch 5S
Sch 10S

Plant Design System (PDS) Piping Component Data

489

Commodity Code Descriptions


L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L

490

AC
AD
AF
AG
AH
AI
AJ
AK
AL
AM
AN
AO
AW
BA
BB
BC
BD
CA
CB
CC
CD
CE
CF
CG
CH
CI
CJ
CK
CL
CM
CN
CO
CP
CQ
CR
CS
CT
CU
CV
CX
DD
MA

S-40S
S-80S
S-10
S-20
S-30
S-40
S-60
S-80
S-100
S-120
S-140
S-160
[???]|bore to match|
S-LW
S-STD
S-XS
S-XXS
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.875 "
0.281 "
2.0 mm

Sch 40S
Sch 80S
Sch 10
Sch 20
Sch 30
Sch 40
Sch 60
Sch 80
Sch 100
Sch 120
Sch 140
Sch 160
[???]
light-weight
standard-weight
X-strong
XX-strong
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.875 "
0.281 "
2.0 mm

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L

MB
MC
MD
ME
MF
MG
MH
MI
MJ
MK
ML
MM
MN
MO
MP
MQ
MR
MS
MT
MU
MV
NA
NB
NC
ND
NE
NF
NG
NJ
NK
NL
NM
NN
NO
NP
NQ
NR
NS
NT
NU
PA
PB

2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
2.2 mm
2.8 mm
3.2 mm
3.8 mm
4.2 mm
4.8 mm
5.5 mm
9.0 mm
11.0 mm
14.0 mm
18.0 mm
22.0 mm
28.0 mm
32.0 mm
38.0 mm
45.0 mm
55.0 mm
70.0 mm
90.0 mm
3.2 mm
4.8 mm

2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
2.2 mm
2.8 mm
3.2 mm
3.8 mm
4.2 mm
4.8 mm
5.5 mm
9.0 mm
11.0 mm
14.0 mm
18.0 mm
22.0 mm
28.0 mm
32.0 mm
38.0 mm
45.0 mm
55.0 mm
70.0 mm
90.0 mm
3.2 mm (0.125) "
4.8 mm (0.188) "

Plant Design System (PDS) Piping Component Data

491

Commodity Code Descriptions

492

L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L

PC
PD
PE
PF
PG
PH
PI
PJ
PK
PL
PM
PN
PO
PP
PQ
PR
PS
ZZ
AA
AAB
AAC
AAD
AAE
AAF
AAG
AAH
AAI

6.4 mm
7.9 mm
9.5 mm
11.1 mm
12.7 mm
14.3 mm
15.9 mm
17.5 mm
19.1 mm
20.6 mm
22.2 mm
23.8 mm
25.4 mm
27.0 mm
28.6 mm
30.2 mm
31.8 mm

AAJ

ASTM-A53-B, galv

AAK

ASTM-A106-B, alum

AAN

ASTM-A106-B, galv

L
L
L

AAO
AAP
AAQ

ASTM-A135-A
ASTM-A135-B
ASTM-A139-A

AAR

ASTM-A139-B

AAS

ASTM-A672-B65

AAT

ASTM-A671-CC60

ASTM-A53-B
ASTM-A53-A
ASTM-A53-F
ASTM-A672-B65
ASTM-A106-B
ASTM-A106-A
ASTM-A106-C
ASTM-A672-C60
ASTM-A53-B, alum

6.4 mm (0.25) "


7.9 mm (0.312) "
9.5 mm (0.375) "
11.1 mm (0.438) "
12.7 mm (0.5) "
14.3 mm (0.562) "
15.9 mm (0.625) "
17.5 mm (0.688) "
19.1 mm (0.75) "
20.6 mm (0.812) "
22.2 mm (0.875) "
23.8 mm (0.938) "
25.4 mm (1) "
27.0 mm (1.062) "
28.6 mm (1.125) "
30.2 mm (1.188) "
31.8 mm (1.25) "

ASTM-A53 Gr.B
ASTM-A53 Gr.A
ASTM-A53 Gr.F
ASTM-A672 Gr.B65
ASTM-A106 Gr.B
ASTM-A106 Gr.A
ASTM-A106 Gr.C
ASTM-A672 Gr.C60
ASTM-A53 Gr.B,
aluminized, per
ASTM-A676
ASTM-A53 Gr.B,
galvanized
ASTM-A106 Gr.B,
aluminized, per
ASTM-A676
ASTM-A106 Gr.B,
galvanized
ASTM-A135 Gr.A
ASTM-A135 Gr.B
ASTM-A139 Gr.A,
ASTM-A285 Gr.C
ASTM-A139 Gr.B,
ASTM-A285 Gr.C
ASTM-A672 Gr.B65, 200
BHN max
ASTM-A671 Gr.CC60
CL22

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


L

AAU

API-5L-A25 Cl.II

AAY

ASTM-A671-CC70 Cl.22

L
L

ABA
ABB

ASME-SA53-B
API-5L-B

L
L
L
L
L

ABC
ABE
ABH
ABL
ABS

API-5L-B
ASTM-A672-C60
ASME-SA106-B
ASTM-A333-6
API-5L-A

ABT

API-5L-B

ABU

API-5L-B

ACS

API-5L-A

ACT

API-5L-B

AZA

CS

EEA

ASTM-A335-P1

EEB

ASTM-A335-P15

EEC

ASTM-A335-P2

EZZ

ASTM-A691-CM70

L
L

FAA
FAB

ASTM-A691-5Cr
ASTM-A387-P9

L
L
L

FAC
FAD
FAE

ASTM-A691-1.25Cr
ASTM-A691/A387-P9
ASTM-A691-2.25 Cr

FFB

ASTM-A335-P12

FFC

ASTM-A335-P11

FFF

ASTM-A335-P22

FFG

ASTM-A335-P21

FFH

ASTM-A335-P5

FFI

ASTM-A335-P5B

FFJ

ASTM-A335-P5C

API-5L Gr.A25, Cl.II,


cold expanded
ASTM-A671 Gr.CC70
Cl.22
ASME-SA53 Gr.B
API-5L Gr.B, 200 BHN
max
API-5L Gr.B, w/PWHT
ASTM-A672 Gr.C60 CL22
ASME-SA106 Gr.B
ASTM-A333 Gr.6
API-5L Gr.A, cold
expanded
API-5L Gr.B, cold
expanded
API-5L Gr.B, 22 HRC
max
API-5L Gr.A, cold
expanded
API-5L Gr.B, cold
expanded
CS (for reinforced
welds & buttwelds)
ASTM-A335 Gr.P1,
C-0.5Mo
ASTM-A335 Gr.P15,
C-11.5Si-0.5Mo
ASTM-A335 Gr.P2,
0.75Cr-0.5Mo
ASTM-A691 Gr.CM70,
C-Mo
ASTM-A691 Gr.5Cr
ASTM-A387 Gr.P9 per
ASTM-A691 modified
ASTM-A691 Gr.1.25Cr
ASTM-A691/A387 Gr.P9
ASTM-A691
Gr.2.25Cr-0.5Mo
ASTM-A335 Gr.P12,
1Cr-0.5Mo
ASTM-A335 Gr.P11,
1.25Cr-0.5Mo
ASTM-A335 Gr.P22,
2.25Cr-1Mo
ASTM-A335 Gr.P21,
3Cr-1Mo
ASTM-A335 Gr.P5,
5Cr-0.5Mo
ASTM-A335 Gr.P5B,
5Cr-0.5Mo-1.5Si
ASTM-A335 Gr.P5C,
5Cr-0.5Mo-Ti OR Cb

Plant Design System (PDS) Piping Component Data

493

Commodity Code Descriptions

494

FFK

ASTM-A335-P7

FFL

ASTM-A335-P9

FGA

ASTM-A336-F11

FGB

ASTM-A336-F22

FGC

ASTM-A336-F21

FZA

Chrome

L
L

GAC
GFD

ASME-SA691-1.25Cr
ASME-SA335 P11

L
L
L

IIA
IIB
IIC

L
L
L
L
L
L
L
L
L
L
L
L
L
L

IID
IIE
IIF
IIG
IIH
III
IIJ
IIK
IIL
IIM
IIN
IIO
IIP
IIQ

ASTM-A312 TP304
ASTM-A312 TP304L
ASTM-A312 TP316L,
w/0.03% C max
ASTM-A312 TP309
ASTM-A312 TP310
ASTM-A312 TP316
ASTM-A312 TP316L
ASME-SA312 TP316L
ASTM-A312 TP317
ASTM-A312 TP321
ASTM-A312 TP321H
ASTM-A312 TP347
ASTM-A312 TP347H
ASTM-A312 TP348
ASTM-A312 TP348H
ASTM-A312 TP304H
ASTM-A358-304

IIR

ASTM-A358-309

IIS

ASTM-A358-310

IIT

ASTM-A358-316

IIU

ASTM-A358-321

IIV

ASTM-A358-347

IIW

ASTM-A358-348

IIX

ASTM-A358-304L

IIY

ASTM-A358-316L

ASTM-A335 Gr.P7,
7Cr-0.5Mo
ASTM-A335 Gr.P9,
9Cr-1Mo
ASTM-A336 Gr.F11,
1.25Cr-0.5Mo
ASTM-A336 Gr.F22,
2.25Cr-1Mo
ASTM-A336 Gr.F21,
3Cr-1Mo
Chrome (for reinforced
welds & buttwelds)
ASME-SA691 Gr.1.25Cr
ASME-SA335 P11,
1.25Cr-0.5Mo
ASTM-A312 Type 304
ASTM-A312 Type 304L
ASTM-A312 Type 316L,
w/0.03% C max
ASTM-A312 Type 309
ASTM-A312 Type 310
ASTM-A312 Type 316
ASTM-A312 TP316L
ASME-SA312 Type 316L
ASTM-A312 Type 317
ASTM-A312 Type 321
ASTM-A312 Type 321H
ASTM-A312 Type 347
ASTM-A312 Type 347H
ASTM-A312 Type 348
ASTM-A312 Type 348H
ASTM-A312 Type 304H
ASTM-A358 Gr.304, A240
Type 304
ASTM-A358 Gr.309, A240
Type 309
ASTM-A358 Gr.310, A240
Type 310
ASTM-A358 Gr.316, A240
Type 316
ASTM-A358 Gr.321, A240
Type 321
ASTM-A358 Gr.347, A240
Type 347
ASTM-A358 Gr.348, A240
Type 348
ASTM-A358 Gr.304L,
A240 Type 304L
ASTM-A358 Gr.316L,
A240 Type 316L

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


L
L
L
L

IIZ
IJQ
IJR
IJS

IJT

L
L
L

IJU
IJV
IJX

IJY

IKH

L
L

IKI
IKJ

IZA

L
L

MLF
MLI

L
L

MLS
OAA

OAB

PAA

SRF

SRG

SRH

SRJ

SRS

SRT

ASTM-A358-304H
ASTM-A409-TP304
ASTM-A409-TP304L
ASTM-A409-TP304, impact
at -325 degF
ASTM-A409-TP316, impact
at -325 degF
ASTM-A409-TP316
ASTM-A409-TP316L
ASTM-A358-304, impact
at -325 degF

ASTM-A358 Gr.304H
ASTM-A409 Type 304
ASTM-A409 Type 304L
ASTM-A409 Type 304,
impact at -325 degF
ASTM-A409 Type 316,
impact at -325 degF
ASTM-A409 Type 316
ASTM-A409 Type 316L
ASTM-A358 Gr.304, A240
TP 304, impact at -325
degF
ASTM-A358-316, impact
ASTM-A358 Gr.316, A240
at -325 degF
TP 316, impact at -325
degF
ASTM-A297-HF modified
ASTM-A297 Gr.HF,
modified
ASTM-A451-CPH 20
ASTM-A451 Gr.CPH-20
ASTM-A451-HF modified
ASTM-A451 Gr.HF
modified
SS
SS (for reinforced
welds & buttwelds)
ASTM-A333-3
ASTM-A333 Gr.3, 3.5Ni
ASTM-A333-4
ASTM-A333 Gr.4, Cr-Cu,
Ni
ASTM-A333-8
ASTM-A333 Gr.8, 9Ni
ASTM-B165 Monel
ASTM-B165, UNS N04400
Monel, annealed, 5 &
under OD "
ASTM-B514
ASTM-B514 Category 2,
UNS N08800
ASTM-B464 Alloy 20
ASTM-B464, UNS N08020,
Alloy 20
ASTM-B241 6063-T6
ASTM-B241 Alloy
6063-T6, as welded, T &
Y tests required
ASTM-B241 6061-T6
ASTM-B241 Alloy
6061-T6, as welded, T &
Y tests required
ASTM-B241 Alloy 6061-T6 ASTM-B261 Alloy
6061-T6, aluminum,
seamless
ASTM-B241 3003-H112
ASTM-B241 Alloy
3003-H112, use annealed
stresses
ASTM-B209 6061-T6
ASTM-B209 Alloy
6061-T6, use welded
stresses
ASTM-B209 6061-T6
ASTM-B209 Alloy
6061-T6, tol to A358,
use welded stresses

Plant Design System (PDS) Piping Component Data

495

Commodity Code Descriptions


L

SZA

Inconel

WAA

API-5L-B, cement lined

WAB

API-5L-B, cement lined,


T & W

WAC

API-5L-B, T & W

WAD

WAE

ASTM-A53-B, cement
lined
ASTM-A53-B, T & W

WAF

ASTM-A53-B, aluminized,
T & W

WXJ

ASTM-A106-B, T & W

WXK

ASTM-A106, epoxy coated

WXL

ASTM-A106-B,
aluminized, T & W

WXM

ASTM-A53-B, cement
lined, T & W

WXN

ASTM-A53-B, galvanized,
T & W

WXV

ASTM-A106-B,
galvanized, T & W

Inconel (for
reinforced welds &
buttwelds)
API-5L Gr.B, cement
lined
API-5L Gr.B, cement
lined, treated &
wrapped
API-5L Gr.B, treated &
wrapped
ASTM-A53 Gr.B, cement
lined
ASTM-A53 Gr.B, treated
& wrapped
ASTM-A53 Gr.B,
aluminized, treated &
wrapped
ASTM-A106 Gr.B,
treated & wrapped
ASTM-A106 Gr.B, epoxy
coated
ASTM-A106 Gr.B,
aluminized, treated &
wrapped
ASTM-A53 Gr.B, cement
lined, treated &
wrapped
ASTM-A53 Gr.B,
galvanized, treated &
wrapped
ASTM-A106 Gr.B,
galvanized, treated &
wrapped

Miscellaneous Wetted Fittings


!0
1
2
!1
2345678901234567890 SHORT DESCRIPTION
LONG DESCRIPTION
!FIRST LETTER: M - MISCELLANEOUS WETTED FITTINGS
M AA
M AB
M EF
M EW
M HR
M PA
M PC

496

Safety shower, w/eye 'Safety shower, w/eye wash'


wash
Safety shower
'Safety shower'
Flanged expansion
joint
Welded expansion
joint
Hose reel assembly

'Flanged expansion joint'

Pig indicator for


S-40
Pig indicator for
S-XS

'Pig indicator for S-40 pipe'

'Welded expansion joint'


'Hose reel assembly'

'Pig indicator for XS pipe'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


M PK

Pig indicator for


S-80
Spray nozzle

'Pig indicator for S-80 pipe'

M AAAA

Speakman SE-505

'Speakman SE-505'

M ABBB

Spray Systems Co

M ABBC

Spray Systems Co

M ABBD

Spray Systems Co

Spray Systems Co Whirljet A30 or


approved equal'
'Spray Systems Co HH7 or approved
equal'
'Spray Systems Co HH6W or approved
equal'

M ABBE

Spray Systems Co

M ABBF

Spray Systems Co

M ABBG

Spray Systems Co

M ABBH

Spraco

M ABBI

Spraco

M ABBJ

Spraco

M HAAA

Halprin Supply Co

M TAAA

T D Williamson Co

M SN

'Spray nozzle'

M ZZ

'Spray Systems Co H20 or approved


equal'
'Spray Systems Co Fulljet GG30 or
approved equal'
'Spray Systems Co Fulljet HH30 or
approved equal'
'Spraco full cone helix nozzle
Model No 60-6713-1607'
'Spraco full cone helix nozzle
Model No 60-6313-1607'
'Spraco full cone helix nozzle
Model No 60-7413-2207'
'Halprin Supply Co Fig No WF314 or
approved equal'
'T D Williamson Co Pig-Sig IID or
approved equal'

M ZZZZ
M IAA

ASTM-A351-CF8

M IAB

ASTM-A276-316

M OAA
M XAI

'ASTM-A351 Gr.CF8, 304 SS'

'ASTM-A276 Type 316, barstock, 316


SS'
ASTM-B408 UNS N08800 'ASTM-B408 UNS N088000, Incoloy
800'
0.059" perf
'0.059" perforations'

M ZZZ

Miscellaneous Non-Wetted Fittings


!0
1
2
!1 2345678901234567890 SHORT DESCRIPTION
LONG DESCRIPTION
!FIRST LETTER: N - MISCELLANEOUS NON-WETTED FITTINGS
N AC
N AD

Vent stack cover


Hose rack

'Vent stack cover'


'Hose rack'

Plant Design System (PDS) Piping Component Data

497

Commodity Code Descriptions


N AE
N AF
N AG
N AH
N AI
N AJ
N AK
N AL
N AM
N AP
N AQ
N CA
N CB
N EA
N FA
N FB
N FC
N FD
N FE
N FF
N FG
N FH
N FI
N FJ
N FK
N FL
N FM
N FN

498

@@Shield for [426] CL150


flange
@@Shield for [426] CL300
flange
@@Shield for [426] CL600
flange
Shield for [426] CL900
flange
Shield for [426] CL1500
flange
Shield for [426] API CL150
flange
Shield for [426] MSS CL150
flange
Shield for [426] API CL300
flange
Shield for [426] MSS CL300
flange
@@Shield for [426] CL300
orifice flange
Shield for [426] CL600
orifice flange
Chain wheel operator
Chain wheel, w/impactor
Gate valve ext stem
@@Shield for [426] Smith
800 valve
@@Shield for [426] Smith
815 valve
@@Shield for [426] Smith
830 valve
@@Shield for [426] Smith
860 valve
@@Shield for [426] Smith
C83 valve
@@Shield for [426] Smith
G80 valve
@@Shield for [426] Smith
G83 valve
@@Shield for [426] Smith
SB80 valve
@@Shield for [426] Crane 33
valve
@@Shield for [426] Crane 47
valve
@@Shield for [426] Crane 76
valve
@@Shield for [426] Crane
143 valve
@@Shield for [426] Crane
151 valve
@@Valve Shield for [426]
Crane B-3655

'Shield for [426] CL150 flange'


'Shield for [426] CL300 flange'
'Shield for [426] CL600 flange'
'Shield for [426] CL900 flange'
'Shield for [426] CL1500
flange'
'Shield for [426] API CL150
flange'
'Shield for [426] MSS CL150
flange'
'Shield for [426] API CL300
flange'
'Shield for [426] MSS CL300
flange'
'Shield for [426] CL300 orifice
flange'
'Shield for [426] CL600 orifice
flange'
'Chain wheel operator'
'Chain wheel operator
w/impactor'
'Gate valve extension stem'
'Shield for [426] Smith 800
valve'
'Shield for [426] Smith 815
valve'
'Shield for [426] Smith 830
valve'
'Shield for [426] Smith 860
valve'
'Shield for [426] Smith C83
valve'
'Shield for [426] Smith G80
valve'
'Shield for [426] Smith G83
valve'
'Shield for [426] Smith SB80
valve'
'Shield for [426] Crane 33
valve'
'Shield for [426] Crane 47
valve'
'Shield for [426] Crane 76
valve'
'Shield for [426] Crane 143
valve'
'Shield for [426] Crane 151
valve'
'Valve Shield for [426] Crane
B-3655'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


N FO
N FP
N FQ
N FR
N FS

@@Shield for [426] Crane


B-3663 valve
@@Shield for [426] Pacific
180
@@Shield for [426] Pacific
380
@@Shield for [426] Mission
Duo-Chek II 15

'Shield for
valve'
'Shield for
valve'
'Shield for
valve'
'Shield for
Duo-Chek II

[426] Crane B-3663


[426] Pacific 180
[426] Pacific 380
[426] Mission
15 valve'

@@Shield for [426] Mission 'Shield for [426] Mission


Duo-Chek II 30
Duo-Chek II 30 valve'

N ZZ
N AAAA
N AAAB

'Apex Hose & Specialty Inc'


@@

'Ramco Manufacturing Co'

N BAAA

'Babbitt'

N BAAB

'Rotohammer'

N BAAC

'Stockham'

N ZZZZ
N AAA

ASTM-A307-A, galv

'ASTM-A307 Gr.A, galvanized'

N IIA

ASTM-A167-TP304 24 Ga

N VAA

rubber

'ASTM-A167 Gr.TP304 24 Ga
sheet'
'rubber'

N VAB

polypropylene

'polypropylene'

N VAC
N ZAA

@@Teflon impregnated glass 'Teflon impregnated glass


cloth
cloth'
cast iron
'cast iron'

N ZAB

ductile iron

'ductile iron'

Tubing and Hose


! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: O - TUBING AND HOSE
O A
O B

Tube PE
Structural tube PE

O C
O D

Single tube, w/sheath


Multitube, w/sheath

Plant Design System (PDS) Piping Component Data

Tubing plain ends


Structural tube plain
ends
Single tube, w/sheath
Multitube, w/sheath

499

Commodity Code Descriptions


O E

Multitube, w/sheath &


phone wire
Multitube/sh/ph/sc

Multitube, w/sheath &


phone wire
Multitube, w/sHeatH,
phone wire & support
cable
Elect traced bundle
Electric traced
bundle
Steam traced bundle
Steam traced bundle
Single tube/insul & jkt Single tube insulated &
jacketed
Double tube/insul & jkt Double tube insulated &
jacketed
Triple tube/insul & jkt Triple tube insulated &
jacketed
Hose
Hose
Hose, w/couplings
Hose, w/couplings
Hose, w/spl bk rings
Hose hub ends, w/split
backing rings
Hose, w/flanged ends
Hose flanged ends,
w/split backing rings
Hose, w/tube adap ends Hose, w/tube adapter
ends
Hose coupling-F spud
Hose coupling female
only
spud only
Hose coupling-M spud
Hose coupling male spud
only
only
Hose fitting
Hose fitting
Hose quick connect
Hose quick connect

O F
O G
O H
O J
O K
O L
O N
O O
O P
O Q
O R
O S
O T
O U
O V
O Z
O
O
O
O
O
O
O
O
O
O

500

A
B
C
D
E
F
G
L
M
Z

CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL125
CL250

CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
CL125
CL250

flat face flanged end


raised face flanged
end
engineered hose
female pipe thread
male pipe thread

O
O

A
B

FFFE
RFFE

O
O
O

E
F
M

engineered hose
FTE
MTE

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


O
O
O

O
W
Z

smls
welded

seamless
welded

2 tube bundle
7 tube bundle
12 tube bundle
19 tube bundle
1 process, w/1 element
2 process, w/1 element
1 process 1 trace,
light
2 process 1 trace,
light
1 process 1 trace,
heavy
2 process 1 trace,
heavy

O
O
O
O
O
O
O

G
L
S
T
U
V

2 tube bundle
7 tube bundle
12 tube bundle
19 tube bundle
1 proc 1 elem
2 proc 1 elem
1 proc 1 trc lt

2 proc 1 trc lt

1 proc 1 trc hvy

2 proc 1 trc hvy

O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

AA
AB
AC
BA
BB
BC
BD
BE
BF
BG
BH
BI
BJ
BK
BL
BM
BN
BO
BP
MA
MB
ZZ
AAD
AAO

Type K
Type L
Type M
0.02 "
0.028 "
0.03 "
0.032 "
0.035 "
0.04 "
0.049 "
0.062"
0.065 "
0.083 "
0.109 "
0.12 "
0.25 "
0.375 "
0.5 "
multi thk per reqn
1.0 mm
0.76 mm
ASTM-A179
CS, cadmium plated

Plant Design System (PDS) Piping Component Data

Type K
Type L
Type M
0.02 "
0.028 "
0.03 "
0.032 "
0.035 "
0.04 "
0.049 "
'0.062"'
0.065 "
0.083 "
0.109 "
0.12 "
0.25 "
0.375 "
0.5 "
multi thk ??
1.0 mm
0.76 mm

ASTM-A179, annealed
CS, cadmium plated,

501

Commodity Code Descriptions

502

AAP

CS, cadmium plated

IIA

ASTM-A269-TP304

IIB

ASTM-A269-TP304L

IIE

ASTM-A269-TP316

IIF

ASTM-A269-TP316

IIG

ASTM-A269-TP316

IIH

316 SS/preinsul/PVC

III

316 SS

IIJ

ASTM-A269-TP321

IIK

ASTM-A269-TP316

IIL

ASTM-A269-TP347

IIM

ASTM-A269-TP316

IIN

ASTM-A269-TP316

IIO

ASTM-A269-TP316

IIP

316 SS

O
O

IIQ
IIR

316 SS
ASTM-A269-TP316

IIS

ASTM-A269-TP316

IJF

ASTM-A213-TP316

IJQ

solid 304 SS

NAA

ASTM-B68 Cu

NAB

copper/fibgl/PVC

NAC

copper/fibgl/PVC

Aeroquip No FD56-1037
CS, cadmium plated,
Dixon Boss X-34
ASTM-A269 Type 304,
annealed
ASTM-A269 Type 304L,
annealed
ASTM-A269 Type 316,
Dekoron 2201
ASTM-A269 Type 316,
annealed
ASTM-A269 Type 316,
Dekoron 2203
ASTM-A269-TP316 smls,
preinsulated tubing,
black PVC jkt, Dekoron
2200
316 stainless stl,
Snap-Tite H Series
nipple end
PHN-F/coupler end
PHC-F
ASTM-A269 Type 321,
annealed
ASTM-A269 Type 316,
Parker 422-208A 812-0
ASTM-A269 Type 347,
annealed
ASTM-A269 Type 316,
Dekoron 2256
ASTM-A269 Type 316,
Dekoron 2266
ASTM-A269 Type 316,
Parker 4412-208A 812-0
316 SS, Evertite Part
FLA
316 SS, Evertite
ASTM-A269 Type 316,
Dekoron 2202
ASTM-A269-TP316,
preinsulated tubing,
3T, 2 process, 1 tracer
ASTM-A213 Type 316,
annealed
solid 304 SS, Dixon
X-34
ASTM-B68, copper, UNS
No C12000
ASTM-B68 UNS C12200 IN
3/8 fiberglass black
PVC jkt Dekoron 2200
ASTM-B68 UNS C12200 IN
3/8 fiberglass black

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions

NAD

NAE

NAF

NPA

NPB

WYH

WYI

WYJ

WYM

WYN

WYO

WYS

WYT

WYU

WYV

WYW

WYX

WYY

O
O

XXX
ZBL

PVC jkt Dekoron 2201


brass
brass, Ever-Tite Part
A
bronze
bronze, Andrews
75-D-BR-VI
ASTM-B280 Cu
ASTM-B280 copper, UNS
No C12200
ASTM-B68 Cu
ASTM-B68, copper, UNS
No C12200
ASTM-B68 Cu
ASTM-B68, copper, UNS
No C12200, 060 temper,
PVC coated
ASTM-A269/poly sheath
ASTM-A269 Type 316,
polyethylene sheath,
Dekoron 2266-30B30
ASTM-A269/poly sheath
ASTM-A269 Type 316,
polyethylene sheath,
Dekoron 2256-30A30
ASTM-A269/poly sheath
ASTM-A269 Type 316,
annealed, fire-retard
polyethylene sheath
aluminum/poly sheath
aluminum 5050-0 in fire
retardant polyethylene
sheath
ASTM-B68 Cu/PVC sheath ASTM-B68 UNS C12200,
copper, in PVC sheath,
Dekoron 1000 Series
ASTM-B68 Cu/poly sheath ASTM-B68 UNS C12200,
copper, IN polyethylene
sheath, Dekoron 1000
Series
Poly tube/PVC sheath
high density
polyethylene tube in PVC
sheath
Poly tube/poly sheath
high density
polyethylene tube in
polyethylene sheath
butyl blend tube
Goodall N-2069, one
end, w/Dixon MG-36,
other end, w/Dixon
MX-16
nitrile blend tube
nitrile blend tube,
w/spiral textile cover,
Goodall L-84
poly tube/steel
polyethylene tube in
light steel conduit
poly tube/galv steel
polyethylene tube in
galvanized steel armor
TFE/304 SS
Teflon, w/304 SS
overbraid

mall iron, cadmium


malleable iron,
plated
cadmium plated, Air King

Plant Design System (PDS) Piping Component Data

503

Commodity Code Descriptions

ZBM

mall iron, cadmium


plated

ZBN

mall iron, cadmium


plated

ZBO

mall iron, cadmium


plated

AM Series
malleable iron,
cadmium plated, Air King
#AM-7 & 12
malleable iron,
cadmium plated, Air King
#AM-8 & 13
malleable iron,
cadmium plated, Air King
#AM-18, 23, & 28

Pipe
! 0 1 2
P ! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: P - PIPE
P AA
@@Pipe, BE
Pipe, beveled ends per
ANSI-B16.25
P AB
@@Pipe, T&C
Pipe, threaded &
coupled
P AC
@@Pipe, T&C, galv
Pipe, threaded &
coupled, galvanized
P AD
@@Pipe, PE
Pipe, plain ends
P AE
Pipe, PE, galv
Pipe, plain ends,
galvanized
P AF
@@Pipe bend, 6D-BR, BE Pipe bend, 6 nominal
pipe diameter radius,
beveled ends per
ANSI-B16.25
>> P AG
Pipe, BE, galv
Pipe, beveled ends,
galvanized
>> P AH
@@Pipe bend, 10D-BR, BE Pipe bend, 10 nominal
pipe diameter radius,
beveled ends per
Pipe bend, 10 nominal
pipe diameter radius,
beveled ends per
ANSI-B16.25
P CC
Pipe, w/split flg
Pipe, w/ends, w/split
flanges
P CD
Pipe, w/tapered ends
Pipe, w/tapered ends for
split flanges
P CE
Pipe, w/ends mach & cpld Pipe, w/ends machined
for rubber ring seals &
coupled
P DU
Duct
Duct
P EA
Pipe, cmt cpld
Pipe, cement coupled
nominal length
P GA
Pipe, groved ends for Pipe, ends grooved for
Vic coupling
Victaulic couplings
P NM
Nipple PE
Nipple, plain ends

504

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


P NN
P NO

Nipple, MTE
Nipple, MTE/PE

P NP
P NQ

Nipple, BE
Nipple, BE/MTE

P OA

@@Nipple, BE, 3 long "

P OB

@@Nipple, MTE, 3 long "

P OC

@@Nipple, PE, 3 long "

P OD

Nipple, BE/MTE, 3 long "

P OE

Nipple, BE/PE, 3 long "

P OF
P OH

@@Nipple, MTE/PE, 3
long "
@@Nipple, BE, 4 long "

P OI

@@Nipple, MTE, 4 long "

P OJ

@@Nipple, PE, 4 long "

P OK

Nipple, BE/MTE, 4 long "

P OL

Nipple, BE/PE, 4 long "

P OM
P OO

@@Nipple, MTE/PE, 4
long "
@@Nipple, BE, 5 long "

P OP

@@Nipple, MTE, 5 long "

P OQ

@@Nipple, PE, 5 long "

P OR

Nipple, BE/MTE, 5 long "

P OS

Nipple, BE/PE, 5 long "

P OT
P PA

@@Nipple, MTE/PE, 5
long "
@@Nipple, BE, 6 long "

P PB

@@Nipple, MTE, 6 long "

P PC

@@Nipple, PE, 6 long "

P PD

Nipple, BE/MTE, 6 long "

P PE

Nipple, BE/PE, 6 long "

P PF

@@Nipple, MTE/PE, 6

Plant Design System (PDS) Piping Component Data

Nipple, threaded ends


Nipple, male threaded x
plain ends
Nipple, beveled ends
Nipple, beveled x male
threaded ends
Nipple, beveled ends, 3
long "
Nipple, male threaded
ends, 3 long "
Nipple, plain ends, 3
long "
Nipple, beveled x male
threaded ends, 3 long "
Nipple, beveled x plain
ends, 3 long "
Nipple, male threaded x
plain ends, 3 long "
Nipple, beveled ends, 4
long "
Nipple, male threaded
ends, 4 long "
Nipple, plain ends, 4
long "
Nipple, beveled x male
threaded ends, 4 long "
Nipple, beveled x plain
ends, 4 long "
Nipple, male threaded x
plain ends, 4 long "
Nipple, beveled ends, 5
long "
Nipple, male threaded
ends, 5 long "
Nipple, plain ends, 5
long "
Nipple, beveled x male
threaded ends, 5 long "
Nipple, beveled x plain
ends, 5 long "
Nipple, male threaded x
plain ends, 5 long "
Nipple, beveled ends, 6
long "
Nipple, male threaded
ends, 6 long "
Nipple, plain ends, 6
long "
Nipple, beveled x male
threaded ends, 6 long "
Nipple, beveled x plain
ends, 6 long "
Nipple, male threaded x

505

Commodity Code Descriptions

P PH
P PI
P PJ
P PK
P PL
P PM
P PO
P PP
P PQ
P PR
P PS
P PT
P QA
P QB
P QC
P QD
P QE
P QF
P QJ
P QK
P QL
P RP
P UA
P UB
P UC

506

long "
plain ends, 6 long "
@@Nipple, BE, 7 long " Nipple, beveled ends, 7
long "
@@Nipple, MTE, 7 long " Nipple, male threaded
ends, 7 long "
@@Nipple, PE, 7 long " Nipple, plain ends, 7
long "
Nipple, BE/MTE, 7 long " Nipple, beveled x male
threaded ends, 7 long "
Nipple, BE/PE, 7 long " Nipple, beveled x plain
ends, 7 long "
@@Nipple, MTE/PE, 7
Nipple, male threaded x
long "
plain ends, 7 long "
Nipple, BE, 8 long "
Nipple, beveled ends, 8
long "
@@Nipple, MTE, 8 long " Nipple, male threaded
ends, 8 long "
@@Nipple, PE, 8 long " Nipple, plain ends, 8
long "
Nipple, BE/MTE, 8 long " Nipple, beveled x male
threaded ends, 8 long "
Nipple, BE/PE, 8 long " Nipple, beveled x plain
ends, 8 long "
Nipple, MTE/PE, 8 long " Nipple, male threaded x
plain ends, 8 long "
Nipple, BE, 9 long "
Nipple, beveled ends, 9
long "
Nipple, MTE, 9 long " Nipple, male threaded
ends, 9 long "
@@Nipple, PE, 9 long " Nipple, plain ends, 9
long "
Nipple, BE/MTE, 9 long " Nipple, beveled x male
threaded ends, 9 long "
Nipple, BE/PE, 9 long " Nipple, beveled x plain
ends, 9 long "
Nipple, MTE/PE, 9 long " Nipple, male threaded x
plain ends, 9 long "
@@Nipple, PE, 10 long " Nipple, plain ends, 10
long "
@@Nipple, PE, 11 long " Nipple, plain ends, 11
long "
@@Nipple, PE, 12 long " Nipple, plain ends, 12
long "
@@Reinforcing pad
Reinforcing pad
Pipe, SPE/BLE, push-on Pipe, spigot x bell ends,
jt, 5 lay lngth
push-on joint, 5 laying
length
@@Pipe, SPE/BLE,
Pipe, spigot x bell ends,
push-on jt, 10 lay
push-on joint, 10 laying
lngth
length
Pipe, PE/BLE, push-on Pipe, plain x bell ends,
jt, 18 lay lngth
push-on joint, 18 laying
length

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


P UD
P UE
P UF
P VP
P UW
P UX
P UY

P
P

AA
AD

AE

AF

AG

AN

AO

AP

P
P
P
P

AX
BA
CT
GA

GF

JA

Pipe, PE/BLE, push-on


jt, 20 lay lngth

Pipe, plain x bell ends,


push-on joint, 20 laying
length
@@Pipe, PE/MJBE, 18
Pipe, plain x mechanical
lay lngth
joint bell ends, 18
laying length
@@Pipe, PE/MJBE, 20
Pipe, plain x mechanical
lay lngth
joint bell ends, 20
laying length
Pressure vessel
Pressure vessel
@@Pipe, PE/BLE, mortar Pipe, plain x bell ends,
jt
mortar joint, laying
length per reqnt
@@Pipe, PE/BLE, push-on Pipe, plain x bell ends,
jt
push-on joint, laying
length per reqnt
@@Pipe, SPE/BLE,
Pipe, spigot x bell ends,
push-on jt
push-on joint, laying
length per reqnt
@@smls
seamless
@@EFW, long seam, 100% electric fusion welded,
JQ
longitudinal seam, 100%
joint quality
EFW, long seam, Cl.42 electric fusion welded,
100% JQ
longitudinal seam, Cl.42
100% joint quality
EFW, long seam, 100%
electric fusion welded,
X-RAY
longitudinal seam, 100%
X-ray 100% joint quality
@@EFW, long seam, Cl.1, electric fusion welded,
100% JQ
longitudinal seam,
Cl.1,100% joint quality
cast, 100% CQ
cast, 100% casting
quality
@@long seam, Cl.22,
electric fusion welded,
100% JQ
longitudinal seam, Cl.22,
100% joint quality
EFW, long seam, Cl.12 electric fusion welded,
100% JQ
longitudinal seam, Cl.12
100% joint quality
@@

forged & bored


forged & bored
spool
spool
cast, 90% CQ
cast, 90% casting
quality
EFW, long seam, 90% JQ electric fusion welded,
longitudinal seam, spot
X-ray, 90% joint quality
@@ERW, long seam, 85% JQ electric resistance
welded, longitudinal
seam, 85% joint quality

Plant Design System (PDS) Piping Component Data

507

Commodity Code Descriptions


P

JD

JG

JN

JR

JS

JT

JU

JV

MA

PB

PC

WA

ZZ

P
P
P
P
P
P
P
P
P
P
P

508

AA
AB
AC
AD
AF
AG
AH
AI
AJ
AK
AL

ERW, long seam, Cl.II, electric resistance,


85% JQ
welded longitudinal seam,
Cl.II, 85% joint quality
@@EFW, long seam, 85% JQ electric fusion welded,
longitudinal seam, double
buttwelded, 85% joint
quality
@@EFW, long seam, Cl.2, electric fusion welded,
85% JQ
longitudinal seam, Cl.2,
85% joint quality
EFW, long seam, Cl.10 electric fusion welded,
85% JQ
longitudinal seam, DSAW,
Cl.10, 85% joint quality
SAW, long seam, 85% JQ submerged arc welded,
longitudinal seam, 85%
joint quality
DSAW, spiral seam, 85% double submerged arc
JQ
welded, spiral seam, 85%
joint quality
DSAW, long seam, 85% JQ double submerged arc
welded, longitudinal
seam, 85% joint quality
@@DSAW, long seam, 95% double submerged arc
JQ
welded, longitudinal
seam, 95% joint quality
EFW, long seam, 80% JQ electric fusion welded,
longitudinal seam, single
welded, 80% joint
quality
EFW, spiral seam, 85% JQ electric fusion weld,
spiral seam, 85% joint
quality
EFW, long seam, 75% JQ electric fusion weld,
longitudinal seam, 75%
joint quality
BW, 60% JQ
buttweld, 60% joint
quality
@@

S-5S
@@S-10S
@@S-40S
@@S-80S
@@S-10
@@S-20
S-30
@@S-40
@@S-60
@@S-80
@@S-100

Sch
Sch
Sch
Sch
Sch
Sch
Sch
Sch
Sch
Sch
Sch

5S
10S
40S
80S
10
20
30
40
60
80
100

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


P
P
P
P
P

AM
AN
AO
AW
AX

@@S-120
S-140
@@S-160
@@[401]
thk per reqn

P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P

BA
BB
BC
BD
BE
CA
CB
CC
CD
CE
CF
CG
CH
CI
CJ
CK
CL
CM
CN
CO
CP
CQ
CR
CS
CT
CU
CV
CW
CX
DD
EA
EB
EC
ED
EE
EF
EG

S-LW
@@S-STD
@@S-XS
@@S-XXS
S-XH
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
@@0.625 "
0.688 "
@@0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.75 "
1.875 "
0.281 "
2 "
2.125 "
2.25 "
2.375 "
2.5 "
2.625 "
2.75 "

Plant Design System (PDS) Piping Component Data

Sch 120
Sch 140
Sch 160
[401]
thk per specification
??
light-weight
standard-weight
X-strong
XX-strong
extra-heavy
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.75 "
1.875 "
0.281 "
2 "
2.125 "
2.25 "
2.375 "
2.5 "
2.625 "
2.75 "

509

Commodity Code Descriptions


P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P

510

EH
FE
MA
MB
MC
MD
ME
MF
MG
MH
MIP
MJ
MK
ML
MM
MN
MO
MP
MQ
MR
MS
MT
MU
MV
NA
NB
NC
ND
NE
NF
NG
NJ
NK
NL
NM
NN
NO
NP
NQ
NR
NS
NT

2.875 "
3.5 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
2.2 mm
2.8 mm
3.2 mm
3.8 mm
4.2 mm
4.8 mm
5.5 mm
9.0 mm
11.0 mm
14.0 mm
18.0 mm
22.0 mm
28.0 mm
32.0 mm
38.0 mm
45.0 mm
55.0 mm
70.0 mm

2.875 "
3.5 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
2.2 mm
2.8 mm
3.2 mm
3.8 mm
4.2 mm
4.8 mm
5.5 mm
9.0 mm
11.0 mm
14.0 mm
18.0 mm
22.0 mm
28.0 mm
32.0 mm
38.0 mm
45.0 mm
55.0 mm
70.0 mm

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P

NU
PA
PB
PC
PD
PE
PF
PG
PH
PI
PJ
PK
PL
PM
PN
PO
PP
PQ
PR
PS
PT
PU
PV
PW
PX
PY
PZ
QA
QB
QC
QD
E
QF
QH
UH
UI
UJ
UK
VA
VB
VC
ZZ

90.0 mm
3.2 mm
4.8 mm
6.4 mm
7.9 mm
9.5 mm
11.1 mm
12.7 mm
14.3 mm
15.9 mm
17.5 mm
19.1 mm
20.6 mm
22.2 mm
23.8 mm
25.4 mm
27.0 mm
28.6 mm
30.2 mm
31.8 mm
37.0 mm
34.0 mm
39.0 mm
56.0 mm
41.0 mm
42.0 mm
29.0 mm
43.0 mm
44.0 mm
45.0 mm
46.0 mm
47.0 mm
26.0 mm
48.0 mm
CL50
CL51
CL52
@@thk per reqnt
@@Wall-A
@@Wall-B
@@Wall-C
@@

Plant Design System (PDS) Piping Component Data

90.0 mm
3.2 mm (0.125) "
4.8 mm (0.188) "
6.4 mm (0.25) "
7.9 mm (0.312) "
9.5 mm (0.375) "
11.1 mm (0.438) "
12.7 mm (0.5) "
14.3 mm (0.562) "
15.9 mm (0.625) "
17.5 mm (0.688) "
19.1 mm (0.75) "
20.6 mm (0.812) "
22.2 mm (0.875) "
23.8 mm (0.938) "
25.4 mm (1) "
27.0 mm (1.062) "
28.6 mm (1.125) "
30.2 mm (1.188) "
31.8 mm (1.25) "
37.0 mm
34.0 mm
39.0 mm
56.0 mm
41.0 mm
42.0 mm
29.0 mm
43.0 mm
44.0 mm
45.0 mm
46.0 mm
47.0 mm
26.0 mm
48.00 mm
Class 50
Class 51
Class 52
thickness per reqnt
Wall-A
Wall-B
Wall-C

511

Commodity Code Descriptions

512

P
P
P
P
P
P
P
P
P

AA
AAB
AAC
AAD
AAE
AAF
AAG
AAH
AAI

@@ASTM-A53-B
ASTM-A53-A
ASTM-A53-F
ASTM-A672-B65
@@ASTM-A106-B
ASTM-A106-A
ASTM-A106-C
ASTM-A672-C60
ASTM-A53-B, alum

AAJ

@@ASTM-A53-B, galv

AAK

ASTM-A106-B, alum

AAN

ASTM-A106-B, galv

P
P
P

AAO
AAP
AAQ

ASTM-A135-A
ASTM-A135-B
ASTM-A139-A

AAR

ASTM-A139-B

AAS

ASTM-A672-B65

P
P

AAT
AAV

ASTM-A671-CC60
API-5L-X42

AAW

API-5L-X46

AAX

API-5L-X52

P
P
P
P
P
P

AAY
AAZ
ABA
ABB
ABC
ABD

P
P
P
P
P
P
P

ABE
ABH
ABL
ABS
ABT
ABU
ACS

ASTM-A671-CC70 Cl.22
ASTM-A53-B
@@ASME-SA53-B
API-5L-B
API-5L-B, w/PWHT
@@ASTM-A671-CC70
Cl.22, impact at -50
degF
ASTM-A672-C60 Cl.22
@@ASME-SA106-B
@@ASTM-A333-6
API-5L-A
@@API-5L-B
API-5L-B
API-5L-A

ASTM-A53 Gr.B
ASTM-A53 Gr.A
ASTM-A53 Gr.F
ASTM-A672 Gr.B65
ASTM-A106 Gr.B
ASTM-A106 Gr.A
ASTM-A106 Gr.C
ASTM-A672 Gr.C60
ASTM-A53 Gr.B,
aluminized per ASTM-A676
ASTM-A53 Gr.B,
galvanized
ASTM-A106 Gr.B,
aluminized per ASTM-A676
ASTM-A106 Gr.B,
galvanized
ASTM-A135 Gr.A
ASTM-A135 Gr.B
ASTM-A139 Gr.A,
ASTM-A285 Gr.C, plate
ASTM-A139 Gr.B,
ASTM-A285 Gr.C, plate
ASTM-A672 Gr.B65, 200
BHN max
ASTM-A671 Gr.CC60 CL22
API-5L Gr.X42, cold
expanded
API-5L Gr.X46, cold
expanded
API-5L Gr.X52, cold
expanded
ASTM-A671 Gr.CC70 Cl.22
ASTM-A53 Type E Gr.B
ASME-SA53 Gr.B
API-5L Gr.B, 200 BHN max
API-5L Gr.B, w/PWHT
ASTM-A671 Gr.CC70 Cl.22,
impact at -50 degF
ASTM-A672 Gr.C60 Cl.22
ASME-SA106 Gr.B
ASTM-A333 Gr.6
API-5L Gr.A
API-5L Gr.B
API-5L Gr.B, 22 HRC max
API-5L Gr.A, cold
expanded

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


P

ACT

API-5L-B

P
P

AXZ
EEA

CS
ASTM-A335-P1

EEB

ASTM-A335-P15

P
P

EXZ
EZZ

carbon moly
ASTM-A691-CM70

P
P
P
P

FAA
FAC
FAD
FAE

ASTM-A691-5Cr
ASTM-A691-1.25Cr
ASTM-A691/A387-P9
ASTM-A691-2.25Cr

FFB

ASTM-A335-P12

P
P

FFC
FFF

@@ASTM-A335-P11
ASTM-A335-P22

FFG

ASTM-A335-P21

P
P

FFH
FFI

@@ASTM-A335-P5
ASTM-A335-P5B

FFJ

ASTM-A335-P5C

FFK

ASTM-A335-P7

P
P

FFL
FGA

@@ASTM-A335-P9
ASTM-A336-F11

FGB

ASTM-A336-F22

FGC

ASTM-A336-F21

FGE

ASTM-A336-F22

P
P
P
P

FXZ
GAC
GFD
GFF

chrome
ASME-SA691-1.25Cr
@@ASME-SA335-P11
ASME-SA335-P22

P
P
P

IIA
IIB
IIC

P
P
P

IID
IIE
IIF

@@ASTM-A312-TP304
@@ASTM-A312-TP304L
ASTM-A312-TP316L,
w/0.03% C max
ASTM-A312-TP309
ASTM-A312-TP310
@@ASTM-A312-TP316

Plant Design System (PDS) Piping Component Data

API-5L Gr.B, cold


expanded
CS
ASTM-A335 Gr.P1,
C-0.5Mo
ASTM-A335 Gr.P15,
C-1-1.5Si-0.5Mo
carbon moly
ASTM-A691 Gr.CM70,
carbon moly
ASTM-A691 Gr.5Cr
ASTM-A691 Gr.1.25Cr
ASTM-A691/A387 Gr.P9
ASTM-A691 Gr.2.25Cr,
2.25Cr-0.5Mo
ASTM-A335 Gr.P12,
1Cr-0.5Mo
ASTM-A335 Gr.P11
ASTM-A335 Gr.P22,
2.25Cr-1Mo
ASTM-A335 Gr.P21,
3Cr-1Mo
ASTM-A335 Gr.P5
ASTM-A335 Gr.P5B,
5Cr-0.5Mo-1.5Si
ASTM-A335 Gr.P5C,
5Cr-0.5Mo-Ti or Cb
ASTM-A335 Gr.P7,
7Cr-0.5Mo
ASTM-A335 Gr.P9
ASTM-A336 Gr.F11,
1.25Cr-0.5Mo
ASTM-A336 Gr.F22,
2.25Cr-1Mo
ASTM-A336 Gr.F21,
3Cr-1Mo
ASTM-A336 Gr.F22,
2.25Cr-1Mo
chrome
ASME-SA691 Gr.1.25Cr
ASME-SA335 Gr.P11
ASME-SA335 Gr.P22,
2.25Cr-0.5Mo
ASTM-A312 Type 304
ASTM-A312 Type 304L
ASTM-A312 Type 316L,
w/0.03% C max
ASTM-A312 Type 309
ASTM-A312 Type 310
ASTM-A312 Type 316

513

Commodity Code Descriptions

514

P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P

IIG
IIH
III
IIJ
IIK
IIL
IIM
IIN
IIO
IIP
IIQ
IIR
IIS
IIT
IIU
IIV
IIW
IIX
IIY
IIZ
IJQ
IJR
IJS

ASTM-A312-TP316L
ASME-SA312-TP316L
ASTM-A312-TP317
@@ASTM-A312-TP321
ASTM-A312-TP321H
ASTM-A312-TP347
ASTM-A312-TP347H
ASTM-A312-TP348
ASTM-A312-TP348H
ASTM-A312-TP304H
@@ASTM-A358-304
ASTM-A358-309
ASTM-A358-310
ASTM-A358-316
ASTM-A358-321
ASTM-A358-347
ASTM-A358-348
ASTM-A358-304L
ASTM-A358-316L
ASTM-A358-304H
ASTM-A409-TP304
ASTM-A409-TP304L
ASTM-A409-TP304,
impact at -325 degF
ASTM-A409-TP316,
impact at -325 degF

ASTM-A312 Type 316L


ASME-SA312 Type 316L
ASTM-A312 Type 317
ASTM-A312 Type 321
ASTM-A312 Type 321H
ASTM-A312 Type 347
ASTM-A312 Type 347H
ASTM-A312 Type 348
ASTM-A312 Type 348H
ASTM-A312 Type 304H
ASTM-A358 Gr.304
ASTM-A358 Gr.309
ASTM-A358 Gr.310
ASTM-A358 Gr.316
ASTM-A358 Gr.321
ASTM-A358 Gr.347
ASTM-A358 Gr.348
ASTM-A358 Gr.304L
ASTM-A358 Gr.316L
ASTM-A358 Gr.304H
ASTM-A409 Type 304
ASTM-A409 Type 304L
ASTM-A409 Type 304,
impact at -325 degF
ASTM-A409 Type 316,
impact at -325 degF

IJT

P
P
P

IJU
IJV
IJX

ASTM-A409-TP316
ASTM-A409-TP316L
@@ASTM-A358-304,
impact at -325 degF
ASTM-A358-316, impact
at -325 degF

ASTM-A409 Type 316


ASTM-A409 Type 316L
ASTM-A358 Gr.304, impact
at -325 degF
ASTM-A358 Gr.316, A240
TP 316, impact at -325
degF
ASTM-A297 Gr.HF
modified
ASTM-A451 Gr.CPH-20
ASTM-A451 Gr.HF
modified
SS
ASTM-A333 Gr.3, 3.5Ni
ASTM-A333 Gr.4, Cr-Cu,
Ni
ASTM-A333 Gr.8, 9Ni
ASTM-B407 UNS N08800,
Incoloy, cold drawn
annealed

IJY

IKH

ASTM-A297-HF modified

P
P

IKI
IKJ

ASTM-A451-CPH 20
ASTM-A451-HF modified

P
P
P

IXZ
MLF
MLI

SS
ASTM-A333-3
ASTM-A333-4

P
P

MLS
OAA

ASTM-A333-8
ASTM-B407 Incoloy

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


P

OAB

PAA

PAP

SRG

SRH

SRJ

SRS

SRT

SRU

SRV

TAA

TAB

UAA

VAA

VBA

VBB

VCA

VDA

ASTM-B514

ASTM-B514 category 2,
UNS N08800
ASTM-B464 Alloy 20
ASTM-B464, UNS N08020,
Alloy 20
ASTM-B241-6063-T6
ASTM-B241 Alloy 6063-T6,
as welded, T & Y tests
required
ASTM-B241-6061-T6
ASTM-B241 Alloy 6061-T6,
as welded, T & Y tests
required
ASTM-B241-6061-T6
ASTM-B241 Alloy 6061-T6,
aluminum, seamless
ASTM-B241-3003-H112
ASTM-B241 Alloy
3003-H112, use annealed
stresses
ASTM-B209-6061-T6
ASTM-B209 Alloy 6061-T6,
use welded stresses
ASTM-B209-6061-T6
ASTM-B209 Alloy 6061-T6,
tol to A358, use welded
stresses
@@ASTM-B168-600
ASTM-B168 Gr.600 UNS
N06600, annealed &
pickled
@@ASTM-B167-600
ASTM-B167 Gr.600 UNS
N06600, cold drawn,
annealed & pickled
ASTM-F441 CPVC
ASTM-F441 Cl.23447-B
CPVC
@@ASTM-D1785 PVC
ASTM-D1785 Cl.12454-B
PVC
ASTM-D2996, epoxy lined ASTM-D2996-RTRP-11FE,
reinforced epoxy lined
@@ASTM-A74 w/rubber
ASTM-A74 w/preformed
gskt
rubber gasket per
ASTM-C564
@@AWWA-C151, dbl thk
ANSI/AWWA-C151/A21.51,
cement lined w/gskt
double thickness cement
lined, asphalt coated,
w/preformed rubber gasket
per
ANSI/AWWA-C111/A21.11
@AWWA-C151 dbl cmnt
ANSI/AWWA-C151/A21.51,
lind w/gskt,glnd & blt double thickness cement
lined, asphalt coated,
mechanical joint
w/preformed rubber gasket
per
ANSI/AWWA-C111/A21.11,
gland & bolts
@@ASTM-C700
ASTM-C700 w/bonded
w/polyurethane compr
polyurethane compression
coupl
coupling per ASTM-C425
ASTM-C76 Cl-I w/rubber ASTM-C76 Cl-I w/rubber
gskt
gasket per ASTM-C443

Plant Design System (PDS) Piping Component Data

515

Commodity Code Descriptions


P

VDB

VDC

VDD

P
P

VDE
WAA

WAB

WAC

WAD

WAE

WAF

WXJ

WXK

WXL

WXM

WXN

WXV

WXW

WXX

WXY

ASTM-C76 Cl-II w/rubber


gskt
@@ASTM-C76 Cl-III
w/rubber gskt
ASTM-C76 Cl-IV w/rubber
gskt
@@ASTM-C76 Cl-III
API-5L-B/cement

ASTM-C76 Cl-II w/rubber


gasket per ASTM-C443
ASTM-C76 Cl-III w/rubber
gasket per ASTM-C443
ASTM-C76 Cl-IV w/rubber
gasket per ASTM-C443
ASTM-C76 Cl-III
API-5L Gr.B, cement
lined
API-5L-B/cement
API-5L Gr.B, cement
lined
API-5L-B/T&W
API-5L Gr.B, treated &
wrapped
ASTM-A53-B/cement/T&W ASTM-A53 Gr.B, cement
lined, treated & wrapped
ASTM-A53-B/T&W
ASTM-A53 Gr.B, treated &
wrapped
ASTM-A53-B/alum/T&W
ASTM-A53 Gr.B,
aluminized, treated &
wrapped
ASTM-A106-B/T&W
ASTM-A106 Gr.B, treated
& wrapped
ASTM-A106/epoxy
ASTM-A106 Gr.B, epoxy
coated
ASTM-A106-B/alum/T&W
ASTM-A106 Gr.B,
aluminized, treated &
wrapped
@@ASTM-A53-B, cement
ASTM-A53 Gr.B, cement
lined/T&W
lined, treated & wrapped
ASTM-A53-B/T&W/galv
ASTM-A53 Gr.B, treated &
wrapped, galvanized
ASTM-A106-B/T&W/galv
ASTM-A106 Gr.B, treated
& wrapped, galvanized
API-5L-B, epoxy lined API-5L Gr.B, epoxy
lined
ASTM-A53-B, epoxy lined ASTM-A53 Gr.B, epoxy
lined
API-5L-B/epoxy,
API-5L Gr.B, epoxy
w/CL150
lined, w/CL150 flanges

Socket Fittings
! 0 1
2
! 1 2345678901234567890
SHORT DESCRIPTION
DESCRIPTION
! FIRST LETTER: Q - SOCKET FITTINGS

516

Q AA

@@Coupling, SE

'Coupling, socket ends'

Q AB

SE half coupling

'Socket end half coupling'

Q AC

SE tang coupling

'Socket end tangential


coupling'

LONG

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


Q AD

SE 45 deg coupling

Q AE

@@Reducing coupling, SE 'Reducing coupling, socket


ends'

Q BA

@@Insert bushing, SE

Q BB

SE red bush male x FTE 'Socket end reducing bushing


male x FPT'

Q CA

@@Cap, SE

'Cap, socket ends'

Q HA

@@Union, SE

'Union, socket end, fitting


material seats'

Q HB

SE union Br/ftg

'Socket end union brass to


fitting material seats'

Q HC

SE orifice union

'Socket end union restriction


orifice'

Q HD

SE union O-ring seat

'Socket end union O-ring seat'

Q HE

SE union, w/gasket

'Socket end union, w/gasket'

Q LA

@@90 deg elbow, SE

'90 deg elbow, socket ends'

Q LB

SE red 90 deg elbow

'Socket end 90 deg reducing


elbow'

Q LC

@@45 deg elbow, SE

'45 deg elbow, socket ends'

Q PA

SE plug

'Socket end plug'

Q PB

SE plug 4" long

'Socket end plug 4" long'

Q SA

SE reducer

Q TA

@@Tee, SE

'Tee, socket ends'

SE red tee

'Socket end reducing tee'

Q TL

SE 45 deg lateral

'Socket end 45 deg lateral


fitting'

Q TM

SE 45 deg red lateral

'Socket end 45 deg reducing


lateral fitting'

Q XA

SE cross

'Socket end cross'

Q Z

@@

Q R

cemented

'cemented'

Q U

insul

'insulating'

Q Z

@@

Q AI

S-40

'Sch 40'

Q AK

@@S-80

'Sch 80'

Q TAA

ASTM-F439 CPVC

'ASTM-F439 CL.23447-B CPVC'

Q TAB

@@ASTM-D2467 PVC

'ASTM-D2467 CL.12454-B PVC'

Q TB

'Socket end 45 deg coupling'

'Insert bushing, socket ends'

'Socket end reducer'

Q ZZ

Plant Design System (PDS) Piping Component Data

517

Commodity Code Descriptions


''

Q ZZZ

Tubing Fittings
!
0
1
2
!
1 2345678901234567890
SHORT DESCRIPTION
DESCRIPTION
!
FIRST LETTER: R - TUBING FITTINGS

518

R BA

Tube clamp

'Tubing clamp'

R CA

Cap

'Tubing cap'

R DB

Male adapter

'Tubing male adapter tube


to pipe'

R DC

Female adapter

'Tubing female adapter tube


to pipe'

R FA

Front ferrule

'Tubing front ferrule for


two ferrule fittings'

R FB

Back ferrule

'Tubing back ferrule for


two ferrule fittings'

R FC

Ferrule

'Tubing ferrule for single


ferrule fittings'

R FD

Sleeve

'Tubing sleeve for 3 piece


flare fittings'

R FE

Front & back ferrule

'Tubing front & back


ferruleS, Swagelok
Ferrule-PAK'

R HA

Union

'Tubing union'

R HB

Reducing union

'Tubing reducing union'

R HC

Bulk union

'Tubing bulkhead union'

R IA

Plastic tube insert

'Plastic tubing insert'

R LA

Union elbow

'Tubing union elbow'

R LC

Male 45 ell

'Tubing male 45 deg elbow'

R LF

Female elbow

'Tubing female elbow'

R LG

Male elbow

'Tubing male elbow'

R LH

Elbow

'Tubing elbow,
joint'

R LI

45 ell

'Tubing 45 deg elbow,


solder joint'

R NA

Nut

'Tubing nut'

R PA

Plug

'Tubing plug'

LONG

solder

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


R QA

Quick conn assem

'Quick connect assembly,


w/full flow'

R QB

Quick conn body assem

'Quick connect body


assembly, w/full flow'

R QC

Quick conn stem assem

'Quick connect stem


assembly, w/full flow'

R QF

Quick conn assem

'Quick connect assembly,


w/single end shut-off'

R QG

Quick conn body assem

'Quick connect body


assembly, w/single end
shut-off'

R QH

Quick conn stem assem

'Quick connect stem


assembly, w/single end
shut-off'

R QL

Quick conn assem

'Quick connect assembly,


w/double end shut-off'

R QM

Quick conn body assem

'Quick connect body


assembly, w/double end
shut-off'

R QN

Quick conn stem assem

'Quick connect stem


assembly, w/double end
shut-off'

R QP

Quick conn body prot plg 'Quick connect body


protector plug'

R QR

Quick conn stem prot cap 'Quick connect stem


protector cap'

R RA

Reducer

'Tubing reducer'

R RB

Reducing port connector

'Tubing reducing port


connector'

R RC

Bulkhead reducer

'Tubing bulkhead reducer'

R RD

Reducing coupling

'Tubing reducing coupling,


solder joint'

R SA

Tube sleeve

'Tubing sleeve'

R TA

Union tee

'Tubing union tee'

R TC

Male run tee

'Tubing male run tee'

R TD

Male branch tee

'Tubing male branch tee'

R TE

Female run tee

'Tubing female run tee'

R TF

Female branch tee

'Tubing female branch tee'

R TG

Tee

'Tubing tee, solder joint'

R TH

Reducing tee

'Tubing reducing tee,


solder joint'

Plant Design System (PDS) Piping Component Data

519

Commodity Code Descriptions


R VB

Female connector

'Tubing female connector'

R VC

Male connector

'Tubing male connector'

R VD

Bulkhead male connector

'Tubing bulkhead male


connector'

R VE

Bulkhead female
connector

'Tubing bulkhead female


connector'

R VF

Reducing FEM connector

'Tubing reducing female


connector'

R VG

Reducing coupling

'Tubing reducing coupling,


solder joint'

R XA

Union cross

'Tubing union cross'

R C

compression metal tube

'metal tube compression'

R D

compression plas tube

'plastic tube compression'

R F

37 flare

'37 deg flare'

R G

45 flare

'45 deg flare'

R K

Crimp ring

'316 SS crimp ring'

R P

soft plas tube

'soft plastic tube'

R Q

hi density plas tube

'high density plastic tube'

R R

Socketwelded

'socketwelded'

R S

silver braze

'silver brazing'

R T

solder

'solder'

R U

THD/coned

'threaded & coned'

R V

THD ferrule

'threaded ferrule'

R Z
R Z

520

''

R A

all tube

'all tube'

R B

all tube metal to plastic 'all tube metal to plastic'

R C

all copper female solder 'all copper female solder


connections
connections'

R F

tube stub to tube

R G

tube stub to female pipe 'tube stub to female pipe


thread
thread'

R H

tube stub to male pipe


thread

'tube stub to male pipe


thread'

R I

tube stub to machined


ferrule

'tube stub to machined


ferrule'

R L

quick conn/FTE

'quick connect to female


pipe thread'

'tube stub to tube'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


R M

quick conn/MTE

'quick connect to male pipe


thread'

R N

quick conn/tube

'quick connect to tube'

R O

tube x male pipe weld

'tube x male pipe weld'

R P

tube x FTE

'tube x female pipe thread'

R Q

tube x MTE

'tube x male pipe thread'

R R

tube x FTE x tube

'tube x female pipe thread


x tube'

R S

tube x MTE x tube

'tube x male pipe thread x


tube'

R T

tube x tube x FTE

'tube x tube x pipe female


thread'

R U

tube x tube x MTE

'tube x tube x male pipe


thread'

R Z

''

R AAA

steel

'steel'

R AAB

steel, cadmium plated

'steel, cadmium plated'

R AAP

steel, w/SS ferrule

'steel, w/SS ferrule'

R AAQ

steel, cadmium plated,


w/SS ferrule

'steel, cadmium plated,


w/SS ferrule, Swagelok'

R AAR

steel

'steel, Ermeto'

R AAS

steel

'steel, Swagelok'

R AAT

steel

'steel, Imperial Hi-Seal'

R AAU

steel, cadmium plated, w/ 'steel, cadmium plated,


SS collets
w/SS collets, Tylok'

R ABA

stl/flare

'steel, flare, Triple-Lok'

R IIA

ASTM-A182-F304

'ASTM-A182 Gr.F304'

R IIB

STM-A182-F304

'ASTM-A182 Gr.F304,
Swagelok'

R IIC

ASTM-A182-F304L

'ASTM-A182 Gr.F304L'

R IIF

ASTM-A182-F316

'ASTM-A182 Gr.F316'

R IIG

316 SS

'316 SS body, LP Type,


Pressure Products
Industries'

R IIH

17-4 PH ferrule

'17-4 PH ferrule, LP Type,


Pressure Products
Industries'

Plant Design System (PDS) Piping Component Data

521

Commodity Code Descriptions

522

R III

416 SS GLD nut

'416 SS gland nut, LP Type,


Pressure Products
Industries'

R IIJ

ASTM-A182-F321

'ASTM-A182 Gr.F321'

R IIK

ASTM-A182-F321

'ASTM-A182 Gr.F321,
Swagelok'

R IIN

316 SS

'316 SS'

R IIO

ASTM-A182-F316

'ASTM-A182 Gr.F316, w/heat


treated CS ferrule, Ermeto
8000'

R IIP

ASTM-A182-F304

'ASTM-A182 Gr.F304, Tylok'

R IIQ

ASTM-A182-F316

'ASTM-A182 Gr.F316, w/17-4


PH ferrule, Ermeto 8000'

R IIR

ASTM-A182-F316

'ASTM-A182 Gr.F316,
Ermeto'

R IIS

ASTM-A182-F316

'ASTM-A182 Gr.F316,
Swagelok'

R IIT

ASTM-A182-F316

'ASTM-A182 Gr.F316,
Imperial Hi-Seal'

R IIU

ASTM-A182-F316

'ASTM-A182 Gr.F316, Tylok'

R IIV

ASTM-A182-F316

'ASTM-A182 Gr.F316, 20000


pound, American Instrument
Co'

R IIW

ASTM-A182-F316

'ASTM-A182 Gr.F316, 30000


pound, American Instrument
Co'

R IIX

ASTM-A182-F316

'ASTM-A182 Gr.F316, 45000


pound, American Instrument
Co'

R IIY

ASTM-A182-F316

'ASTM-A182 Gr.F316,
Swagelok QC Series or
approved equal'

R IIZ

ASTM-A182-F316

'ASTM-A182 Gr.F316,
Swagelok QF Series or
approved equal'

R IJL

ASTM-A182-F347

'ASTM-A182 Gr.F347, Tylok'

R NOA

bronze

'bronze, Walseal'

R NOB

bronze

'bronze'

R NOF

brass

'brass inset, American


Pamcor, AMP-FIT'

R NOJ

brass, cadmium plated

'brass, cadmium plated'

R NPA

copper

'wrought copper'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


R NPC

ASTM-B36

'ASTM-B36, UNS C26800'

R NPD

brass, cadmium plated

'brass, cadmium plated,


Swagelok'

R NPE

brass

'brass'

R NPF

brass, ferrule & nut

'nickel plated brass, Zytel


ferrule, knurled nut,
Swagelok'

R NPG

brass, ferrule & nut

'brass, Zytel ferrule,


knurled nut, Swagelok'

R NPJ

brass, cadmium plated

'brass, cadmium plated'

R NPK

brass

'brass compression,
Imperial'

R NPM

brass

'brass, Imperial Poly-Flo'

R NPQ

brass

'brass, Gyrolok'

R NPR

brass

'brass, Ermeto'

R NPS

brass

'brass, Swagelok'

R NPT

brass, cadmium plated

'brass, cadmium plated,


Imperial Hi-Duty'

R NPU

brass

'brass, Tylok, no equal'

R NPV

brass

'brass, Imperial Hi-Seal'

R NPW

brass

'brass, Imperial Hi-Duty'

R NPX

brass

'brass, Imperial Poly-Flo


to Hi-Duty'

R NPY

brass flare

'brass flare'

R ONF

Hast B

'Hastelloy B, Swagelok'

R ONH

Monel

'Monel'

R ONJ

Monel

'Monel, Swagelok'

R ONO

nickel

'nickel'

R SRH

aluminum

'aluminum'

R SRS

aluminum

'aluminum, Swagelok, no
equal'

R SRU

aluminum

'aluminum, Imperial
Hi-Seal'

R TUA

black plastic

'black plastic, American


Pamcor, Amp-Fit'

R TUF

polyethylene

'polyethylene'

R TUL

polystyrene

'polystyrene'

Plant Design System (PDS) Piping Component Data

523

Commodity Code Descriptions


R TUY

Teflon, w/ferrule, nut & 'Teflon body w/ferrule,


split sleeve
Kynar nut & KEL-F split
sleeve'

Socketwelded Fittings
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: S - SOCKETWELDED FITTINGS

524

S AA

@@Coupling, SWE

Coupling, socketwelded
ends

S AB

SWE half coupling

Socketwelded half
coupling

S AC

SWE tang coupling

Socketwelded tangential
coupling

S AD

SWE 45 deg coupling

Socketwelded 45 deg
coupling

S AE

SWE coupling 3.25 long

Socketwelded 3.25 long


coupling "

S BA

SWE insert

Socketwelded insert
bushing

S BB

SWE red bush male x FTE

Socketwelded reducing
bushing male x FPT

S CA

@@Cap, SWE

Cap, socketwelded ends

S HA

@@Union, SWE

Union, socketwelded
ends, fitting material
seats

S HB

SWE union Br/ftg

Socketwelded union brass


to fitting material
seats

S HC

SWE orifice union

Socketwelded union
restriction orifice

S HD

SWE union O-ring seat

Socketwelded union
O-ring seat

S HE

SWE union, w/gasket

Socketwelded union,
w/gasket

S LA

@@90 deg elbow, SWE

90 deg elbow,
socketwelded ends

S LB

SWE red 90 deg elbow

Socketwelded 90 deg
reducing elbow

S LC

@@45 deg elbow, SWE

45 deg elbow,

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


socketwelded ends
S PA

SWE plug

Socketwelded plug

S PB

SWE plug 4 long "

Socketwelded plug 4
long "

S SA

SWE reducer

Socketwelded reducer

S TA

@@Tee, SWE

Tee, socketwelded ends

S TB

@@Reducing tee, SWE

Reducing tee,
socketwelded ends

S TL

@@45 deg lateral, SWE

45 deg lateral,
socketwelded ends

S TM

@@45 deg reducing


lateral, SWE

45 deg reducing lateral,


socketwelded ends

S XA

SWE cross

Socketwelded cross

CL150

CL150

CL300

CL300

CL2500

CL2500

@@CL3000

CL3000

@@CL6000

CL6000

@@CL9000

CL9000

cemented

cemented

insul

insulating

round bar

round barstock

hex bar

hex barstock

API

API

@@

AI

S-40

Sch 40

AK

S-80

Sch 80

AO

S-160

Sch 160

BB

S-STD

standard-weight

BC

S-XS

X-strong

BD

S-XXS

XX-strong

ZZ

@@

Plant Design System (PDS) Piping Component Data

525

Commodity Code Descriptions

526

AAA

@@ASTM-A105

ASTM-A105

AAD

ASME-SA234-WPB

ASME-SA234 Gr.WPB

AAN

ASTM-A105, galv

ASTM-A105, galvanized

AAS

ASTM-A105

ASTM-A105, MCC Marpac

AAT

ASME-SA105

ASME-SA105, MCC Marpac

ABB

@@ASTM-A350-LF2

ASTM-A350 Gr.LF2

ABE

@@ASME-SA105

ASME-SA105

FFB

ASTM-A182-F12

ASTM-A182 Gr.F12,
1Cr-0.5Mo

FFC

@@ASTM-A182-F11

ASTM-A182 Gr.F11

FFF

ASTM-A182-F22

ASTM-A182 Gr.F22,
2.25Cr-1Mo

FFG

ASTM-A182-F21

ASTM-A182 Gr.F21,
3Cr-1Mo to ASTM-A234

FFH

@@ASTM-A182-F5

ASTM-A182 Gr.F5

FFI

ASTM-A182-F5A

ASTM-A182 Gr.F5A,
5.5Cr-0.5Mo

FFK

ASTM-A182-F7

ASTM-A182 Gr.F7,
7Cr-0.5Mo

FFL

@@ASTM-A182-F9

ASTM-A182 Gr.F9

GFD

@@ASME-SA182-F11

ASME-SA182 Gr.F11

GFF

ASSME-SA182-F22

ASME-SA182 Gr.F22,
2.25Cr-1Mo

IIA

@@ASTM-A182-F304

ASTM-A182 Gr.F304

IIB

@@ASTM-A182-F304L

ASTM-A182 Gr.F304L

IIE

ASTM-A182-F310

ASTM-A182 Gr.F310

IIF

@@ASTM-A182-F316

ASTM-A182 Gr.F316

IIG

ASTM-A182-F316L

ASTM-A182 Gr.F316L

IIH

ASME-SA182-F316L

ASME-SA182 Gr.F316L

IIJ

@@ASTM-A182-F321

ASTM-A182 Gr.F321

IIL

ASTM-A182-F347

ASTM-A182 Gr.F347

IIN

ASTM-A182-F348

ASTM-A182 Gr.F348

IIP

ASTM-A182-F304H

ASTM-A182 Gr.F304H

IIY

ASTM-A182-F347H

ASTM-A182 Gr.F347H

IJF

ASTM-182-F316L, special

ASTM-182 Gr.F316L,
w/0.035% C max, 12% Ni
min, 2.2% Mo min

OAC

ASTM-B564

ASTM-B564 UNS NO8800,

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


Incoloy 800
S

OAD

@@ASTM-B366-WPNC1

ASTM-B366 Gr.WPNC1 UNS


N06600

SRF

aluminum

ASTM-B361, Alloy
WP6063-T6, aluminum

SRG

aluminum

ASTM-B361, Alloy
WP6061-T6, aluminum

TAA

ASTM-F439 CPVC

ASTM-F439 Cl.23447-B,
CPVC

TAB

ASTM-D2467 PVC

ASTM-D2467 Cl.12454-B
PVC

Threaded Fittings
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: T - THREADED FITTINGS
T AA

@@Coupling, FTE

Coupling, female
threaded ends

T AC

FTE tang coupling

Threaded tangential
coupling

T AD

THD combo coupling

Threaded combination
coupling

T AE

FTE coupling 3.25 long Threaded coupling 3.25


"
long "

T AF

Red FTE coupling

Reducing threaded
coupling

T BA

THD hex bushing

Threaded hex head


bushing

T BB

THD fl bushing

Threaded flush bushing

T BC

THD red bushing

Threaded reducing
bushing

T CA

@@Cap, FTE

Cap, female threaded


ends

T DA

THD adapter

Threaded adapter

T DB

THD red adapter

Threaded reducing
adapter

T HA

@@Union, FTE

Union, female threaded


ends, fitting material
seats

T HB

FTE union Br/ftg

Threaded union brass to

Plant Design System (PDS) Piping Component Data

527

Commodity Code Descriptions


fitting material seats

528

T HC

FTE orifice union

Threaded union
restriction orifice

T HD

FTE union O-ring seat Threaded union O-ring


seat

T LA

@@90 deg elbow, FTE

90 deg elbow, female


threaded ends

T LB

Red THD 90 deg elbow

Reducing threaded 90 deg


elbow

T LC

@@90 deg street elbow, 90 deg street elbow,


FTE
female threaded ends

T LD

@@45 deg elbow, FTE

45 deg elbow, female


threaded ends

T PA

@@Plug, MTE

Plug, male threaded end

T PB

MTE plug 4 long "

Threaded plug 4 long "

T SA

@@Reducer, FTE

Reducer, female threaded


ends

T TA

@@Tee, FTE

Tee, female threaded


ends

T TB

@@Reducing tee, FTE

Reducing tee, female


threaded ends

T TC

THD serv tee

Threaded service tee

T TL

@@Lateral, FTE

Lateral, female threaded


ends

T TM

@@Reducing lateral,
FTE

Reducing lateral, female


threaded ends

T UA

THD retn bend

Threaded return bend


medium

T XA

THD cross

Threaded cross

CL150

CL150

@@CL300

CL300

CL2500

CL2500

CL125

CL125

CL250

CL250

CL2000

CL2000

@@CL3000

CL3000

@@CL6000

CL6000

CL9000

CL9000

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


T

@@

MTE/red FTE

male x reduced female


thread

FTE/red MTE

female to reduced male


thread

M SW/FTE

male socketwelded x
female threaded

F SW/FTE

female socketwelded x
female thread

MTE/FTE

male x female threaded

insul

insulating

@@round head

round head

hex head

hex head

API

API

sq head

square head

@@

AI

S-40

Sch 40

AK

S-80

Sch 80

AO

S-160

Sch 160

AW

[???]|bore to match|

[???]

BA

S-LW

light-weight

BB

S-STD

standard-weight

BC

S-XS

X-strong

BD

S-XXS

XX-strong

ZZ

@@

AAA

@@ASTM-A105

ASTM-A105

AAE

ASTM-A106-B

ASTM-A106 Gr.B

AAF

ASTM-A106-A

ASTM-A106 Gr.A

AAM

ASTM-A105, alum

ASTM-A105, aluminized to
ASTM-A676

AAN

@@ASTM-A105, galv

ASTM-A105, galvanized

AAT

API-5L-B

API-5L Gr.B

AAU

ASTM-A108-G10180

ASTM-A108 UNS G10180

AAX

AISI-1018

AISI-1018 barstock

Plant Design System (PDS) Piping Component Data

529

Commodity Code Descriptions

530

AAY

AISI-1018

AISI-1025 barstock

AAZ

AISI-4140

AISI-4140 barstock

ABB

@@ASTM-A350-LF2

ASTM-A350 Gr.LF2

ABE

@@ASME-SA105

ASME-SA105

EEA

ASTM-A182-F1

ASTM-A182 Gr.F1 UNS


K12822, C-0.5Mo

EEC

ASTM-A182-F1 mod

ASTM-A182 Gr.F1, C-0.5Mo


modified, w/0.5Cr

FFB

ASTM-A182-F12

ASTM-A182 Gr.F12,
1Cr-0.5Mo

FFC

@@ASTM-A182-F11

ASTM-A182 Gr.F11

FFF

ASTM-A182-F22

ASTM-A182 Gr.F22,
2.25Cr-1Mo

FFG

ASTM-A182-F21

ASTM-A182 Gr.F21,
3Cr-1Mo

FFH

@@ASTM-A182-F5

ASTM-A182 Gr.F5

FFI

ASTM-A182-F5A

ASTM-A182 Gr.F5A,
5Cr-0.5Mo

FFK

ASTM-A182-F7

ASTM-A182 Gr.F7,
7Cr-0.5Mo

FFL

@@ASTM-A182-F9

ASTM-A182 Gr.F9

GFD

@@ASME-SA182-F11

ASME-SA182 Gr.F11

GFF

ASME-SA182-F22

ASME-SA182 Gr.F22,
2.25Cr-1Mo

HIO

ASTM-A276-TP410

ASTM-A276 Type 410

IIA

@@ASTM-A182-F304

ASTM-A182 Gr.F304

IIB

@@ASTM-A182-F304L

ASTM-A182 Gr.F304L

IIE

ASTM-A182-F310

ASTM-A182 Gr.F310

IIF

@@ASTM-A182-F316

ASTM-A182 Gr.F316

IIG

ASTM-A182-F316L

ASTM-A182 Gr.F316L

IIH

ASTM-A182-F316L,
w/0.030% C max

ASTM-A182 Gr.F316L,
w/0.030% C max

IIJ

@@ASTM-A182-F321

ASTM-A182 Gr.F321

IIL

ASTM-A182-F347

ASTM-A182 Gr.F347

IIN

ASTM-A182-F348

ASTM-A182 Gr.F348

IIP

ASTM-A182-F304H

ASTM-A182 Gr.F304H

IIQ

ASTM-A276-TP304

ASTM-A276 Type 304,


barstock

IIR

ASTM-A276-TP304L

ASTM-A276 Type 304L,

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


barstock
T

IIU

ASTM-A276-TP316L

ASTM-A276 Type 316L,


barstock

IIV

ASTM-A276-TP316

ASTM-A276 Type 316,


barstock

IIW

ASTM-A276-TP347

ASTM-A276 Type 347,


barstock

IIY

ASTM-A182-F347H

ASTM-A182 Gr.F347H

IJF

ASTM-A182-F316L,
special

ASTM-A182 Gr.F316L,
w/0.035% C max, 12% Ni
min, 2.2% Mo min

IJK

ASTM-A182-F316,
modified

ASTM-A182 Gr.F316
modified, w/0.03% C max,
11.5% Ni min

IJL

ASTM-A182-F316L

ASTM-A182 Gr.F316L,
w/11.5% Ni min

MLF

ASTM-A350-LF3

ASTM-A350 Gr.LF3, 3.5Ni

NAB

ASTM-B16

ASTM-B16 UNS C36000,


brass

NAC

Cu/steel

copper/ASTM-A105

NPE

brass

brass

OAA

ASTM-B564

ASTM-B564 UNS NO4400,


Monel

OAD

@@ASTM-B366-WPNC1

ASTM-B366 Gr.WPNC1 UNS


N06600

OND

ASTM-B366

ASTM-B366 Gr.WPNC,
Monel

PAA

ASTM-B462

ASTM-B462 UNS NO8020,


Alloy 20

SRG

aluminum

ASTM-B247, Alloy
6061-T6, aluminum

SRJ

aluminum

ASTM-B247, Alloy
3003-HII2, aluminum

SRS

aluminum

ASTM-B221, Alloy
6061-T6

SRU

aluminum

ASTM-B26, Alloy GS42-A

TAA

ASTM-F439 CPVC

ASTM-F439 Cl.23447-B
CPVC

TAB

ASTM-D2467 PVC

ASTM-D2467 Cl.12454-B
PVC

WAA

ASTM-A105 T&W

ASTM-A105 treated &


wrapped

Plant Design System (PDS) Piping Component Data

531

Commodity Code Descriptions


T

WAB

ASTM-A105, alum, T&W

ASTM-A105, aluminized,
treated & wrapped

ZDK

ASTM-A338 Mall, galv

ASTM-A338, malleable
iron, galvanized

ZDL

ASTM-A395 DI, galv

ASTM-A395, ductile iron,


galvanized

ZDM

ASTM-A395 DI

ASTM-A395, ductile iron

ZDP

@@ASTM-A197 malleable ASTM-A197 malleable


iron, galv
iron, galvanized

Underground Fittings
!
!
!

532

0
1
2
1
2345678901234567890
SHORT DESCRIPTION
LONG DESCRIPTION
FIRST LETTER: U - UNDERGROUND FITTINGS

U AA

@@1/4 bend

'Quarter bend'

U AD

@@1/8 bend

'Eight bend'

U AI

1/16 bend

'Sixthteen bend'

U CA

@@Connecting piece

'Connecting piece'

U DC

@@Double hub

'Double hub'

U DD

Short solid sleeve

'Short solid sleeve'

U FA

@@Flanged connecting piece

'Flanged connecting piece'

U LA

@@Wye

'Wye'

U LB

@@Reducing wye

'Reducing wye'

U LC

True Wye

'True wye'

U LD

True reducing wye

'True reducing wye'

U LG

Reducing wye w/branch


cleanout

'Reducing wye with branch


cleanout with threaded plug'

U LH

Reducing wye w/main cleanout 'Reducing wye with main


cleanout with threaded plug'

U MA

@@Body ferrule w/thrd plug

'Body ferrule with threaded


plug'

U PA

Threaded plug

'Threaded plug'

U PB

@@Plug

'Plug'

U RA

@@Concentric reducer

'Concentric reducer'

U RB

Eccentric reducer

'Eccentric reducer'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


U RC

@@Concentric increaser

'Concentric increaser'

U TA

@@Tee

'Tee'

U TB

@@Reducing tee

'Reducing tee'

' '

U A

CL25

'CL25'

U B

CL125

'CL125'

U C

CL150

'CL150'

U D

CL175

'CL175'

U E

@@CL250

'CL250'

U F

CL300

'CL300'

U G

@@CL350

'CL350'

U Z

@@

''

U C

@@FFFE/PE

'flat face flanged end x


plain end'

U D

@@BLE, push-on jt

'bell ends, push-on joint'

U E

@@MJBE

'mechanical joint bell ends'

U F

@@SPE

'spigot ends'

U G

@@PE/MJBE

'plain x mechanical joint


bell ends'

U H

@@SPE/BLE, push-on jt

'spigot x bell ends, push-on


joint'

U I

@@PE/BLE, push-on jt

'plain x bell ends, push-on


joint'

U J

@@PLE/BLSE, push-on jt

'plain large x bell small


ends, push-on joint'

U K

@@PLE/MJBSE

'plain large x mechanical


joint bell small ends'

U L

@@SPLE/BLSE, push-on jt

'spigot large x bell small


ends, push-on joint'

U M

@@BLE/SPE/BLE, push-on jt

'bell x spigot x bell ends,


push-on joint'

U N

@@BLE/PE/BLE, push-on jt

'bell x plain x bell ends,


push-on joint'

U P

MJBE/PE/MJBE

'mechanical joint bell x


plain x mechanical joint
bell ends'

U R

@@PE

'plain ends'

U Z

''

Plant Design System (PDS) Piping Component Data

533

Commodity Code Descriptions


U B

S-40

'Sch 40'

U C

S-80

'Sch 80'

U D

@@S-XS

'X-strong'

U E

S-160

Sch 160'

U G

S-XXS

'XX-strong'

U L

S-C50

Class 50'

U M

S-C51

'Class 51'

U N

S-C52

'Class 52'

U S

S-STD

'standard-weight'

U T

@@S-XH

'extra-heavy'

U U

S-SW

'service-weight'

U X

thk per reqn

thk per specification ??'

@@

''

! 0
1
2
! 1
2345678901234567890
DESCRIPTION

534

SHORT DESCRIPTION

U A

@@CL125 ANSI-B16.1 drilling 'CL 125 ANSI-B16.1


drilling'

U Z

@@

''

U VAA

@@ASTM-A74 w/rubber gskt

'ASTM-A74 w/preformed
rubber gasket per
ASTM-C564'

U VBA

AWWA-C110, dbl thk cement


lined w/gskt

'ANSI/AWWA-C110/A21.10,
double thickness cement
lined, asphalt coated,
push-on joint w/preformed
rubber gasket per
ANSI/AWWA-C111/A21.11'

U VBB

@AWWA-C110, dbl cmnt lnd


w/gskt,glnd & blt

'ANSI/AWWA-C110/A21.10,
double thickness cement
lined, asphalt coated,
mechanical w/preformed
rubber gasket per
ANSI/AWWA-C111/A21.11,
gland & bolts'

U VBC

AWWA-C110 w/gskt

'ANSI/AWWA-C110/A21.10,
asphalt coated, push-on
joint w/preformed rubber
gasket per
ANSI/AWWA-C111/A21.11'

LONG

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


U VBD

AWWA-C110 w/gskt,glnd & blt 'ANSI/AWWA-C110/A21.10,


asphalt coated,mechanical
w/preformed rubber gasket
per ANSI/AWWA-C111/A21.11,
gland & bolts'

U VCA

@@ASTM-C700 w/polyurethane
compr coupl

'ASTM-C700 w/bonded
polyurethane compression
coupling per ASTM-C425'

U VCB

@@polyurethane/clay

'polyurethane/clay'

U VGH

@@ASTM-A74 w/brass plug

'ASTM-A74 w/brass plug'

U VGI

@@AWWA-C110, dbl thk cement 'ANSI/AWWA-C110/A21.10


lined
double thickness cement
lined, asphalt coated'

Valves
! 0
1
2
! 1
2345678901234567890
DESCRIPTION
! FIRST LETTER: V - VALVES

SHORT DESCRIPTION

V A

@@Gate valve

'Gate valve'

V B

@@Globe valve

'Globe valve'

V C

@@Check valve

'Check valve'

V D

@@Ball valve

'Ball valve'

V E

@@Plug valve

'Plug valve'

V F

@@Butterfly valve

'Butterfly valve'

V G

@@HP butterfly valve

'High performance butterfly


valve'

V H

Diaphragm valve

'Diaphragm valve'

V I

Control valve

'Control valve'

V J

Slide valve

'Slide valve'

V K

Knife valve

'Knife valve'

V L

@@Angle valve

'Angle valve'

V M

Sample valve

'Sampling valve'

V N

@@Needle valve

'Needle valve'

V O

@@Deluge valve

'Deluge valve'

V P

Pipeline valve

'Pipeline valve'

V R

Relief valve

'Relief valve'

V S

Stop check

'Stop check'

Plant Design System (PDS) Piping Component Data

LONG

535

Commodity Code Descriptions

536

V T

Flush bottom valve

'Flush bottom valve'

V V

Instr valve

'Instrument valve'

V W

@@Check valve, wafer

'Check valve, wafer'

V X

Special valve per reqn

'valve ??'

V Y

@@Y-globe valve

'Y-globe valve'

V A

@@CL150

'CL150'

V B

@@CL300

'CL300'

V C

@@CL400

'CL400'

V D

@@CL600

'CL600'

V E

@@CL900

'CL900'

V F

@@CL1500

'CL1500'

V G

CL2500

'CL2500'

V H

CL4500

'CL4500'

V K

CL75

'CL75'

V L

@@CL125

'CL125'

V M

CL250

'CL250'

V N

@@CL200

'CL200'

V O

CL2000

'CL2000'

V P

CL3000

'CL3000'

V Q

CL5000

'CL5000'

V R

CL10000

'CL10000'

V S

CL15000

'CL15000'

V T

CL20000

'CL20000'

V U

@@CL800

'CL800'

V V

3000 WOG

'3000 WOG'

V W

6000 WOG

'6000 WOG'

V X

@@rating per reqn

'rating ??'

V A

@@FFFE

'flat face flanged ends'

V B

@@RFFE

'raised face flanged ends'

V D

@@RFFE, 125 Ra finish

'raised face flanged ends, 125


Ra finish'

V E

BE/FTE

'male buttwelded x female


threaded ends'

V F

M SWE/FTE

'male socketweldeded x female


threaded ends'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V G

MTE/FTE

'male threaded x female


threaded ends'

V H

@@SWE/FTE

'socketwelded x female threaded


ends'

V J

@@RJFE

'ring joint flanged ends'

V K

MSWE/FSWE

'male socketwelded x female


socketwelded ends'

V L

lens joint

'lens joint flanged ends'

V M

RFFE, 125-500 Ra finish

'raised face flanged ends,


125-500 Ra finish'

V N

RFFE, 63-250 Ra finish

'raised face flanged ends,


63-250 Ra finish'

V O

RFFE, 63-125 Ra Finish

'raised face flanged ends,


63-125 Ra finish'

V P

RFFE, 125-250 Ra finish

'raised face flanged ends,


125-250 Ra finish'

V R

RFFE, 3 Ra finish

'raised face flanged ends, 3 Ra


finish'

V S

@@SWE

'socketwelded ends'

V T

@@FTE

'female threaded ends'

tube conn

'tubing connection'

V V

Victaulic ends

'Victaulic ends'

V W

@@BW

'buttwelded ends'

V X

@@ends per reqn

'ends ??'

V A

@@carbon steel

'carbon steel'

V B

C-0.5Mo

'C-0.5Mo'

V C

@@1.25Cr

'1.25Cr'

V D

2.25Cr

'2.25Cr'

V E

@@5Cr

'5Cr'

V F

@@9Cr

'9Cr'

V G

12CR

'12Cr'

V H

other Cr

'other Cr'

V I

@@304 SS

'304 SS'

V J

@@304L SS

'304L SS'

V K

@@316 SS

'316 SS'

V L

@@316L SS

'316L SS'

V M

@@321 SS

'321 SS'

V N

@@347 SS

'347 SS'

Plant Design System (PDS) Piping Component Data

537

Commodity Code Descriptions


V O

H Gr SS

'H Gr.SS'

V R

400 SS

'400 Series SS'

V S

@@low temp CS

'low temperature carbon steel'

V T

@@cast iron

'cast iron'

V U

@@ductile iron

'ductile iron'

V V

malleable iron

'malleable iron'

V W

@@Cu

'copper'

V X

@@Ni

'nickel'

V Y

Al

'aluminum'

V Z

538

'other non ferrous'

V 2

@@thermoplastic

'thermoplastic'

V 3

thermoset plastic

'thermoset plastic'

V 4

non metalic

'non metalic'

V 5

@@lined

'lined'

V 6

coated

'coated'

V 9

matl per reqn

'matl ??'

V A

@@trim 1

'API trim 1'

V B

@@trim 2

'API trim 2'

V C

trim 3

'trim 3'

V D

trim 4

'trim 4'

V E

@@trim 5

'API trim 5'

V F

trim 6

'trim 6'

V G

@@trim 7

'API trim 7'

V H

@@trim 8

'API trim 8'

V I

@@trim 9

'API trim 9'

V J

@@trim 10

'API trim 10'

V K

trim 11

'trim 11'

V L

@@trim 12

'API trim 12'

V M

@@trim 13

'API trim 13'

V N

trim 14

'trim 14'

V Q

@@butterfly valve trim

'butterfly valve trim'

V R

@@butterfly valve trim

'butterfly valve trim'

V S

@@HP butterfly valve fire 'HP butterfly valve fire safe


safe trim
trim'

V T

other HP butterfly valve 'other HP butterfly valve trim'


trim

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V U

@@ball valve fire safe


trim

'ball valve fire safe trim'

V V

@@ball valve trim

'ball valve trim'

V W

ball valve trim

'ball valve trim'

V X

@@trim per reqn

'trim ??'

V Z

@@

''

V AA

Bonney Forge H9-16

'Bonney Forge H9-16'

V AB

@@Bonney Forge H9-36

'Bonney Forge H9-36'

V AC

@@Bonney Forge H9-56

'Bonney Forge H9-56'

V AD

@@Bonney Forge H9F-11

'Bonney Forge H9F-11'

V AE

@@Bonney Forge H9F-19

'Bonney Forge H9F-19'

V AF

@@Bonney Forge WL-41

'Bonney Forge WL-41'

V AG

@@Bonney Forge W9-39

'Bonney Forge W9-39'

V AH

@@Bonney Forge W9-49

'Bonney Forge W9-49'

V AI

@@Bonney Forge Y9-41

'Bonney Forge Y9-41'

V AJ

@@Bonney Forge H9-10

'Bonney Forge H9-10'

V AK

@@Bonney Forge H9-30

'Bonney Forge H9-30'

V AL

@@Bonney Forge H9-50

'Bonney Forge H9-50'

V AM

@@Bonney Forge L1-10

'Bonney Forge L1-10'

V AN

@@Bonney Forge L3-10

'Bonney Forge L3-10'

V AO

@@Bonney Forge HL-30

'Bonney Forge HL-30'

V AP

@@Bonney Forge HL-50

'Bonney Forge HL-50'

V AQ

@@Bonney Forge H9F-12

'Bonney Forge H9F-12'

V AR

@@Bonney Forge Y9-42

'Bonney Forge Y9-42'

V AS

@@Bonney Forge W9-10

'Bonney Forge W9-10'

V AT

@@Bonney Forge H9F-10

'Bonney Forge H9F-10'

V AU

@@Bonney Forge W9-30

'Bonney Forge W9-30'

V AV

@@Bonney Forge W9-50

'Bonney Forge W9-50'

V AW

@@Bonney Forge L6-10

'Bonney Forge L6-10'

V AX

@@Bonney Forge HL-10

'Bonney Forge HL-10'

V AY

@@Bonney Forge H9F-16

'Bonney Forge H9F-16'

V AZ

@@Bonney Forge Y9-46

'Bonney Forge Y9-46'

V BA

@@Bonney Forge W9-11

'Bonney Forge W9-11'

V BB

@@Bonney Forge W9-31

'Bonney Forge W9-31'

V BC

@@Bonney Forge W9-41

'Bonney Forge W9-41'

Plant Design System (PDS) Piping Component Data

539

Commodity Code Descriptions

540

V BD

@@Bonney Forge Y9-40

'Bonney Forge Y9-40'

V BE

@@Bonney Forge W9-40

'Bonney Forge W9-40'

V BF

@@Bonney Forge W9-36

'Bonney Forge W9-36'

V BG

@@Bonney Forge H9F-30

'Bonney Forge H9F-30'

V BH

@@Bonney Forge H9F-50

'Bonney Forge H9F-50'

V BI

@@Bonney Forge W9-46

'Bonney Forge W9-46'

V CA

@@Crane 33

'Crane 33'

V CB

@@Crane 33 1/2

'Crane 33 1/2'

V CC

@@Crane 47

'Crane 47'

V CD

Crane 55

'Crane 55'

V CE

@@Crane 76

'Crane 76'

V CF

@@Crane 143

'Crane 143'

V CG

@@Crane 151

'Crane 151'

V CH

@@Crane 151 1/2

'Crane 151 1/2'

V CI

@@Crane 787

'Crane 787'

V CJ

Crane 1523

'Crane 1523'

V CK

@@Crane 7189

'Crane 7189'

V CL

@@Crane 9302

'Crane 9302'

V CM

@@Crane B-3655

'Crane B-3655'

V CN

@@Crane B-3663

'Crane B-3663'

V CO

@@Crane 47, w/MSS-SP-44


flanged ends

'Crane 47, w/MSS-SP-44 flanged


ends'

V CP

@@Crane 55, w/MSS-SP-44


flanged ends

'Crane 55, w/MSS-SP-44 flanged


ends'

V CQ

@@Crane 14 1/2 P

'Crane 14 1/2 P'

V CR

@@Crane 36

'Crane 36'

V CS

@@Crane 431 UB

'Crane 431 UB'

V CT

@@Crane 33, w/MSS-SP-44


flanged ends

'Crane 33, w/MSS-SP-44 flanged


ends'

V CU

@@Crane 88

'Crane 88'

V CW

@@Crane 1523 1/2

'Crane 1523 1/2'

V CX

@@Crane 137

'Crane 137'

V CY

@@Crane 76 1/2

'Crane 76 1/2'

V CZ

@@Crane 171 1/2

'Crane 171 1/2'

V DA

@@Crane 171

'Crane 171'

V DB

@@Crane 87

'Crane 87'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V DC

@@Crane 189

'Crane 189'

V DD

@@Crane 373

'Crane 373'

V EA

@@Rockwell 1925

'Rockwell 1925'

V EB

@@Rockwell 1945

'Rockwell 1945'

V EC

@@Rockwell 4149

'Rockwell 4149'

V ED

@@Rockwell McCanna S151

'Rockwell McCanna S151'

V EE

@@Rockwell Edward 36124

'Rockwell Edward 36124'

V EF

@@Rockwell Edward 36128

'Rockwell Edward 36128'

V EG

@@Rockwell 2245

'Rockwell 2245'

V EH

@@Rockwell Edward 7514Y

'Rockwell Edward 7514Y'

V EI

@@Rockwell McCanna S301

'Rockwell Mc CannaS301'

V EJ

@@Rockwell 2025

'Rockwell 2025'

V EK

@@Rockwell 2045

'Rockwell 2045'

V EL

@@Rockwell 4249

'Rockwell 4249'

V EM

@@Rockwell 2249

'Rockwell 2249'

V EN

@@Rockwell 4749

'Rockwell 4749'

V EO

@@Rockwell Edward 36178

'Rockwell Edward 36178'

V EP

Rockwell Edward 832Y

'Rockwell Edward 832Y'

V EQ

Rockwell Edward 670Y

'Rockwell Edward 670Y'

V ER

Rockwell Edward 36174

'Rockwell Edward 36174'

V ES

Rockwell Edward 1570Y

'Rockwell Edward 1570Y'

V ET

Rockwell Edward 607Y

'Rockwell Edward 607Y'

V EU

Rockwell Edward 4007Y

'Rockwell Edward 4007Y'

V EV

Rockwell Edward 7507Y

'Rockwell Edward 7507Y'

V EW

Rockwell Edward 1641Y

'Rockwell Edward 1641Y'

V EX

Rockwell Edward 36164

'Rockwell Edward 36164'

V EY

Rockwell Edward 7502Y

'Rockwell Edward 7502Y'

V EZ

Rockwell Edward 36168

'Rockwell Edward 36168'

V FA

Rockwell Edward 66124

'Rockwell Edward 66124'

V FB

Rockwell Edward 66128

'Rockwell Edward 66128'

V FC

@@Rockwell 1947

'Rockwell 1947'

V FW

Watts 900

Watts 900'

V FX

Watts 909

'Watts 909'

V GA

@@Smith 800

'Smith 800'

V GB

@@Smith 870

'Smith 870'

Plant Design System (PDS) Piping Component Data

541

Commodity Code Descriptions

542

V GC

@@Smith 888

'Smith 888'

V GD

@@Smith 5870

'Smith 5870'

V GE

@@Smith 1500

'Smith 1500'

V GF

@@Smith 1570

'Smith 1570'

V GG

@@Smith 815

'Smith 815'

V GH

@@Smith 830

'Smith 830'

V GI

@@Smith G80

'Smith G80'

V GJ

@@Smith G87

'Smith G87'

V GK

@@Smith G150

'Smith G150'

V GL

@@Smith G157

'Smith G157'

V GM

@@Smith SB80

'Smith SB80'

V GN

@@Smith C150

'Smith C150'

V GO

@@Smith 860

'Smith 860'

V GP

@Smith G83

'Smith G83'

V GQ

@@Smith C83

'Smith C83'

V GR

Smith B80

'Smith B80'

V GS

Smith 411F

'Smith 411F'

V GT

Smith 411T

'Smith 411T'

V HA

ITT Grinnell Cam-Tite


3010-1-3

'ITT Grinnell Cam-Tite


3010-1-3'

V HB

ITT Grinnell Cam-Tite


3014-1-3

'ITT Grinnell Cam-Tite


3014-1-3'

V HP

Hancock 5505W

'Hancock 5505W'

V HQ

Hancock 7105W

'Hancock 7105W'

V IA

@@Jamesbury 4CB

'Jamesbury 4CB'

V IB

@@Jamesbury 5150

'Jamesbury 5150'

V IC

@@Jamesbury 5300

'Jamesbury 5300'

V ID

@@Jamesbury A11

'Jamesbury A11'

V IE

@@Jamesbury 4AB

'Jamesbury 4AB'

V IF

@@Jamesbury A11

'Jamesbury A11'

V JA

@@Stockham D623

'Stockham D623'

V JB

@@Stockham D512

'Stockham D512'

V JC

@@Stockham D931

'Stockham D931'

V KA

Hex HG-651

'Hex HG-651'

V KB

Hex HG-463

'Hex HG-463'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V KC

Hex HG-461

'Hex HG-461'

V KD

Hex HB-241

'Hex HB-241'

V KE

Hex HB-521

'Hex HB-521'

V KF

Hex HB-501

'Hex HB-501'

V KH

Hex HN-491

'Hex HN-491'

V KI

Hex HM-571

'Hex HM-571'

V KJ

Hex HM-451

'Hex HM-451'

V KK

Hex HM-131

'Hex HM-131'

V LA

@@Mission Duo Chek II 15

'Mission Duo Chek II 15'

V LB

@@Mission Duo Chek II 30

'Mission Duo Chek II 30'

V LC

@@Mission Duo Chek II 30


for MSS-SP-44

'Mission Duo Chek II 30 for


MSS-SP-44 flanged ends'

V LD

@@Mission Duo Chek II 15 'Mission Duo Chek II 15 for


for MSS-SP-44
MSS-SP-44 flanged ends'

V LE

@@Mission Duo Chek II 60

V LF

'Mission Duo Chek II 60'

@@Mission Duo Chek II 12 'Mission Duo Chek II 12'

V MA

@@Aloyco 2214-A

'Aloyco 2214-A'

V MB

@@Aloyco 2314-A

'Aloyco 2314-A'

V MC

@@Aloyco 374

'Aloyco 374'

V MD

@@Aloyco 377

'Aloyco 377'

V ME

@@Aloyco 114

'Aloyco 114'

V MF

@@Aloyco 117

'Aloyco 117'

V MG

@@Aloyco 317

'Aloyco 317'

V MH

@@Aloyco 2117

'Aloyco 2117'

V MI

@@Aloyco 110

'Aloyco 110'

V MJ

@@Aloyco 114EB

'Aloyco 114EB'

V MK

@@Aloyco 117EB

'Aloyco 117EB'

V ML

@@Aloyco 2117EB

'Aloyco 2117EB'

V MM

@@Aloyco 314

'Aloyco 314'

V MN

@@Aloyco 314EB

'Aloyco 314EB'

V MO

@@Aloyco 317EB

'Aloyco 317EB'

V MP

@@Aloyco 2317A

'Aloyco 2317A'

V MQ

@@Aloyco 2374

'Aloyco 2374'

V MR

@@Aloyco 2377

'Aloyco 2377'

V MS

@@Aloyco 110EB

'Aloyco 110EB'

V MT

@@Aloyco 2110

'Aloyco 2110'

Plant Design System (PDS) Piping Component Data

543

Commodity Code Descriptions


V MU

@@Aloyco 2114

'Aloyco 2114'

V MV

Aloyco 2117A

'Aloyco 2117A'

V MW

Aloyco 2210A

'Aloyco 2110A'

V MX

Aloyco 4217A

'Aloyco 4217A'

V MY

Aloyco 4227

'Aloyco 4227'

V MZ

Aloyco 4210A

'Aloyco 4210A'

V NA

Aloyco 4214A

'Aloyco 4214A'

V NB

Aloyco 2317

'Aloyco 2317'

V NC

Aloyco 4327

'Aloyco 4327'

V ND

Aloyco 4314A

'Aloyco 4314A'

V NE

Aloyco 374

'Aloyco 374'

V NF

Aloyco 4387

'Aloyco 4387'

V NG

Aloyco 4374

'Aloyco 4374'

V NH

Aloyco 62

'Aloyco 62'

V OA

@@Pacific 160

'Pacific 160'

V OB

@@Pacific 180

'Pacific 180'

V OC

@@Pacific 380

'Pacific 380'

V OD

@@Pacific 660

'Pacific 660'

V OE

@@Pacific 680

'Pacific 680'

V OF

@@Pacific 1584

'Pacific 1584'

V OG

@@Pacific 2155

'Pacific 2155'

V OH

@@Pacific 2355

'Pacific 2355'

V OI

@@Pacific 2655

'Pacific 2655'

V OJ

544

@@Pacific 55515

'Pacific 55515'

V OK

@@Pacific 56009

'Pacific 56009'

V OL

@@Pacific 56015

'Pacific 56015'

V OM

Pacific 58009

'Pacific 58009'

V ON

@@Pacific 58815

'Pacific 58815'

V OO

@@Pacific 180, w/MSS-SP-44 'Pacific 180, w/MSS-SP-44


flanged ends
flanged ends'

V OP

@@Pacific 21555

'Pacific 21555'

V OQ

@@Pacific 360

'Pacific 360'

V OR

@@Pacific 55509

'Pacific 55509'

V OS

@@Pacific 58809

'Pacific 58809'

V OT

Pacific 350

'Pacific 350'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V OU

@@Pacific 2955

'Pacific 2955'

V OV

@@Pacific 21553

'Pacific 21553'

V OW

Pacific 56509

'Pacific 56509'

V OX

@@Pacific 1550

'Pacific 1550'

V OY

@@Pacific 960

'Pacific 960'

V OZ

@@Pacific 984

'Pacific 984'

V QA

@@Pratt PIVA

'Pratt PIVA'

V QB

@@Pratt GROUNDHOG

'Pratt GROUNDHOG'

V QK

@@Posi-Seal Phoenix III 232 'Posi-Seal Phoenix III 232'

V QL

@@Posi-Seal Phoenix III 232 'Posi-Seal Phoenix III 232


for MSS-SP-44
for MSS-SP-44 flanged ends'

V QM

@@Posi-Seal Phoenix III 242 'Posi-Seal Phoenix III 242'

V QN

@@Posi-Seal Phoenix III 242 'Posi-Seal Phoenix III 242


for MSS-SP-44
for MSS-SP-44 flanged ends'

V QO

@@Posi-Seal Cryo Firesafe


636

'Posi-Seal Cryo Firesafe


636'

V QP

@@Posi-Seal Cryo Firesafe


636 for SP-44

'Posi-Seal Cryo Firesafe 636


for MSS-SP-44 flanged ends'

V QQ

@@Posi-Seal Cryo Firesafe


646

'Posi-Seal Cryo Firesafe


646'

V QR

Posi-Seal Cryo Firesafe 646 'Posi-Seal Cryo Firesafe


646'

V QS

Posi-Seal Cryo Firesafe


646, w/sP-44 drill

'Posi-Seal Cryo Firesafe


646, w/MSS-SP-44 drilling'

V RA

@@Vogt 22461

'Vogt 22461'

V RB

@@Vogt 15373

'Vogt 15373'

V RC

Vogt 15401

'Vogt 15401'

V RD

Vogt SWS74

'Vogt SWS74'

V RJ

@@Centerline 504

'Centerline 504'

V RK

@@Centerline A

'Centerline A'

V RL

@@Centerline LT

'Centerline LT'

V RN

@@R&G Sloane 1081

'R&G Sloane 1081'

V SA

Powell 1331

'Powell 1331'

V UA

Demco NE

'Demco NE'

V UB

Demco NF

'Demco NF'

V UC

Demco WF

'Demco WF'

V UF

Mueller 31

'Mueller 31'

V UG

Mueller 61

'Mueller 61'

Plant Design System (PDS) Piping Component Data

545

Commodity Code Descriptions


V VA

@@Grinnell Fire Protection 'Grinnell Fire Protection


A-4
Multimatic A-4'

V VP

@@Powhatan 18-157

'Powhatan 18-157'

V YA

Yarway 3486-R

'Yarway 3486-R'

V YB

Yarway 3488-R

'Yarway 3488-R'

V AA

@@

''

V AB

@@min temp to -50 degF

'min temperature to -50 degF'

V AC

@@min temp to -150 degF

'min temperature to -150


degF'

V AD

@@min temp to -325 degF

'min temperature to -325


degF'

V BA

@@RFTBE

'lug or wafer type, raised


face thru-bolted ends'

V BB

@@RFTBCSE,

'single flange, raised face


thru-bolted flanged ends,
drilled & tapped for cap
screws'

V BC

@@RFTBEWG

'wafer, raised face


thru-bolted ends w/integral
gasket'

V BF

@@FFTBE

'wafer, flat face


thru-bolted ends'

V BG

@@FFTBEWG, GO side hndwhl

'wafer, flat face


thru-bolted ends w/integral
gasket, gear operator w/side
mounted hanwheel'

V BH

@@RFTBE, min temp to -50


degF

'raised face thru-bolted


ends, min temperature to -50
degF'

V BI

@@RFTBE, min temp to -325


degF

'raised face thru-bolted


ends, min temperature to -325
degF'

V BJ

V BK

546

@@FFTBSCEWG

'single flange, flat face


thru-bolted ends w/integral
gasket, drilled & tapped for
cap screws'

@@FFTBCSEWG, GO side hndwhl 'single flange, flat face


thru-bolted ends w/integral
gasket, drilled & tapped for
cap screws, gear operator
w/side mounted handwheel'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V BW

@@MJBE, GO side hndwhl


w/gskt, glnd & blt

'mechanical joint bell ends,


gear operator w/side mounted
handwheel w/gaskets, glands
& bolts'

V BN

@@RFTBE, NACE

'lug or wafer type, raised


face thru-bolted ends, NACE
service'

V BP

@@FFTBEWG

'wafer, flat face


thru-bolted ends w/integral
gasket'

V BQ

@@FFTBSCEWG

'wafer, flat face


thru-bolted ends w/integral
gasket, drilled & tapped for
cap screws, gear operator
w/side mounted handwheel'

V BZ

@@FFTBEWG, extended bon, GO 'wafer, flat face


w/side hndwhl
thru-bolted ends w/integral
gasket, extended bonnet,
gear operator w/side mounted
handwheel'

V CA

thru-bolt, w/GO

'raised face thru-bolted


flanged ends, w/gear
operator'

V CB

GO, tap locn G

'gear operator, tapping


location G'

V CC

@@RFTBCSE, GO w/side hndwhl 'single flange, raised face


thru-bolted flanged ends,
drilled & tapped for cap
screws, gear operator w/side
mounted handwheel'

V CD

heat jkt/thru-bolt

'provide Contro heat jacket,


w/each valve, thru-bolted'

V CE

@@NACE, GO

'NACE service, gear operator


w/shaft at right angle to
pipeline'

V CI

no Cu alloys, GO

'no copper alloys, w/gear


operator shaft at right angle
to pipeline'

V CK

thru-bolt, no Cu alloys

'raised face thru-bolted


flanged ends, no copper
alloys permitted'

V CL

D & T mach/no Cu/GO

'lug type, drill & tap for


machine bolts/gear opr/no
copper alloys'

Plant Design System (PDS) Piping Component Data

547

Commodity Code Descriptions


V CM

'lug type, drilled & tapped


for machine bolts/no copper
alloys'

V CN

high temp/GO

'high temperature/right
angle gear oper'

V CP

high temp/GO/D&T

'high temperature/right
angle gear oper D&T machine
bolts'

V CT

tap locn G/no Cu alloys

'tapping, location G, for


ammonia service, no copper
alloys permitted'

V CY

lug Type, D&T, GO

'lug type, drill & tapped for


machine bolts, gear
operator'

V DA

GO, SWE tap at locn C

'gear operator, SWE tap at


locn C in view facing
handwheel, shaft right angle
to pipeline'

V DB

548

D & T mach/no Cu

GO, SWE tap at locn D

'gear opr, SWE tap at locn D


in view facing wheel, shaft
right angle to pipeline'

V DC

GO, SWE tap at locn C

'gear opr, SWE tap at locn C,


handwheel right side, shaft
parallel to pipeline'

V DD

GO, SWE tap at locn D

'gear opr, SWE tap at locn D,


handwheel right side, shaft
parallel to pipeline'

V DE

gear, SWE tap at locn C

'gear operator, SWE tap at


locn C, pinion shaft to right
side of valve'

V DF

gear, SWE tap at locn D

'gear operator, SWE tap at


locn D, pinion shaft to right
side of valve'

V DG

gear, SWE tap at locn F

'gear operator, SWE tap at


locn F, pinion shaft to right
side of valve'

V DH

GO, SWE tap at locn E

'gear operator, SWE tap at


location E, shaft parallel to
pipeline'

V DI

GO, SWE tap at locn F

'gear operator, SWE tap at


location F, shaft parallel to
pipeline'

V DJ

GO, SWE tap at locn B

'gear operator, SWE tap at


location B, shaft parallel to
pipeline'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V DK

GO, SWE tap at locn A

'gear operator, SWE tap at


location A, shaft parallel to
pipeline'

V DL

GO, SWE tap at locn F

'gear opr, SWE tap @ locn degF


in view facing wheel, shaft
right angle to pipeline'

V DM

GO/tap locn D/bypass

'gear opr, SWE tap locn D,


hndwhl right side, shaft
parallel/pipe, bypass locn
A&B'

V DN

GO/tap locn C/bypass

'gear opr, SWE tap locn C,


hndwhl right side, shaft
parallel/pipe, bypass locn
A&B'

V DO

GO/tap locn D/bypass

'gear opr, SWE tap locn D view


facing whl, shaft right
angle/pipe, bypass locn A&B'

V DP

GO/SWE tap locn E

'gear opr, SWE tap at locn E,


view facing wheel, shaft
right angle to pipeline'

V DQ

GO/tap locn C/bypass

'gear operator, SWE tap locn


C, shaft right angle to pipe,
bypass locn A&B'

V EA

bypass/SWE tap locn D

'built in bypass location A &


B, SWE tap at location D'

V EC

epoxy lined

'epoxy lined'

V ED

@@RFTBCSE, 12" extended


bonnet/stem

'single flange, raised face


thru-bolted flanged ends,
drilled & tapped for cap
screws, 12" extended
bonnet/stem'

V EE

@@RFTBCSE, 12" extended


bonnet/stem w/GO

'single flange, raised face


thru-bolted flanged ends,
drilled & tapped for cap
screws, 12" extended
bonnet/stem, gear operator
w/side mounted handwheel'

V EF

@@RFTBCSE, std extended


bonnet/stem

'single flange, raised face


thru-bolted flanged ends,
drilled & tapped for cap
screws, standard extended
bonnet/stem'

Plant Design System (PDS) Piping Component Data

549

Commodity Code Descriptions

550

V EG

@@RFTBCSE, std extended


bonnet/stem w/GO

'single flange, raised face


thru-bolted flanged ends,
drilled & tapped for cap
screws, standard extended
bonnet/stem, gear operator
w/side mounted handwheel'

V FA

built in bypass

'built in bypass'

V FB

orifice thru wedge

'provide, w/0.125" diam


orifice thru center of wedge'

V FL

GO/rt ang/lmt switch

'gear operator, shaft right


angle to pipe, limit
switches'

V GC

GO/one side

'gear operator, shaft to one


side of valve'

V GH

GO

'gear operator'

V GP

GO, parallel

'gear operator, shaft


parallel to pipeline'

V GR

@@GO w/side hndwhl

'gear operator w/side


mounted handwheel'

V GX

@@GO w/top hndwhl

'gear operator w/top mounted


handwheel'

V GY

gear/right angle

'gear operator, shaft at


right angle to pipeline'

V GZ

gear/parallel

'gear operator, shaft


parallel to pipeline'

V JA

jacketed

'jacketed'

V MK

3 way

'multi port, 3 way valve'

V ML

4 way

'multi port, 4 way valve'

V RA

@@no Cu alloys

'for ammonia service, no


copper alloys permitted'

V RB

no Cu alloys

'no copper or copper alloys


permitted'

V RC

chlorine service

'chlorine service'

V RD

DEA/MEA service

'DEA/MEA service'

V RE

@@NACE

'NACE service'

V RN

ultra high temp

'ultra high temperature


service'

V RO

oxygen service

'oxygen service'

V SD

SWE at locn D

'socketwelded connection at
location D'

V SE

SWE at locn E

'socketwelded connection at
location E'

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


V SG

SWE at locn G

'socketwelded connection at
location G'

V TA

tap at locn A

'tap at location A'

V TC

tap at locn C

'tap at location C'

V TD

tap at locn D

'tap at location D'

V TG

tap at locn G

'tap at location G'

V TH

tap at locn G & H

'tap at locations G & H'

V TU

RFTBFE, drain tap

'raised face thru-bolted


flanged ends, drain tap on
valve body'

V WA

wrench

'wrench, w/each valve'

Welded Fittings
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: W - WELDED FITTINGS
W AA
W AB
W AC
W AD
W AG
W AH
W BA
W BC
W BD
W BE
W CA
W DA
W DB
W DC
W OA
W OB

@@90 deg elbow, BE

90 deg long radius


elbow, beveled ends
Reducing 90 deg LR
Reducing 90 deg long
elbow, BE
radius elbow, beveled
ends
@@90 deg SR elbow, BE 90 deg short radius
elbow, beveled ends
@@45 deg elbow, BE
45 deg elbow, beveled
ends
Miter elbow, 2 piece
Weld miter 45 elbow, 2
piece 1 weld
Miter elbow, 3 piece
Weld miter elbow, 3
piece 2 weld type A
@@Stub end per
Stub end per
ANSI-B16.9
ANSI-B16.9
Stub end MSS-SP-43 Tp A Stub end MSS-SP-43 Type
A
Stub end MSS-SP-43 Tp B Stub end MSS-SP-43 Type
B
Stub end MSS-SP-43 Tp C Stub end MSS-SP-43 Type
C
@@Cap, BE
Cap, beveled ends
Weld boss
Weld boss
THD half coupling
Threaded half
coupling
@@Coupling
Coupling
@@Weldolet
Weldolet
@@Sockolet
Sockolet

Plant Design System (PDS) Piping Component Data

551

Commodity Code Descriptions


W
W
W
W
W
W
W
W
W
W
W
W
W
W

OC
OD
OE
OF
OG
OH
OI
OJ
OK
OS
OT
OU
OV
OX

W ZA
W ZB
W __

Thredolet
Elbolet
"
Nipolet 3.5 long "
"
Nipolet 4.5 long "
"
Nipolet 5.5 long "
"
Nipolet 6.5 long "
Latrolet
Weld boss
Weld saddle
Sweepolet
Flat weldolet
Flat sockolet
Flat thredolet
Weldolet, calculation
required
Sockolet
Sockolet, calculation
required
Thredolet
Thredolet, calculation
required
@@Concentric reducer, Concentric reducer,
BE
beveled ends
@@Eccentric reducer, BE Eccentric reducer,
beveled ends
@@Concentric swage
Concentric swage
@@Eccentric swage
Eccentric swage
@@Tee, BE
Tee, beveled ends
@@Reducing tee, BE
Reducing tee, beveled
ends
Weld 45 deg lateral
Weld 45 deg lateral
fitting
Reducing weld 45 deg
Reducing weld 45 deg
lateral
lateral fitting
Weld retn bend LR
Weld return bend long
radius
Weld retn bend SR
Weld return bend short
radius
Weld cross
Weld cross
Reducing weld cross
Reducing weld cross
Weld 45 lateral reinf Weld 45 deg lateral
reinforced
Buttweld
Buttweld
@@Reinforcing weld
Reinforcing weld
Standard fittings
Cap/ell/tee

W
W

@@BE
BE LT

W OY
W OZ
W RA
W RB
W
W
W
W

SA
SB
TA
TB

W TL
W TM
W UA
W UB
W XA
W XB
W YA

552

AA
AB

@@Thredolet
@@Elbolet
Nipolet 3.5 long
Nipolet 4.5 long
Nipolet 5.5 long
Nipolet 6.5 long
@@Latrolet
Weld boss
Weld saddle
Sweepolet
@@Flat weldolet
@@Flat sockolet
Flat thredolet
Weldolet

beveled ends
bevel ends long
tangent

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


W
W
W
W

AZ
BA
CA
CB

CC

CD

CE

CF

CG

FB

FD

FF

FG

FH

FI

FJ

W
W
W

SA
TA
ZZ

W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

AA
AB
AC
AD
AF
AG
AH
AI
AJ
AK
AL
AM
AN
AO
AW

@@PE
plain ends
@@MTE
male threaded ends
MTLE/BSE
thread large end &
bevel small end
@@BLE/MTSE
beveled large x male
threaded small ends
GLE/TSE
groove large end & THD
small end
MTLE/PSE
thread large end &
plain small end
@@PLE/MTSE
plain large x male
thread small ends
@@BLE/PSE
bevel large x plain
small ends
@@RFFE
raised face flanged
ends
RFFE, 125 Ra finish
raised face flanged
ends, 125 Ra finish
RFFE, 125-250 Ra finish raised face flanged
ends, 125-250 Ra finish
RFFE, 63-250 Ra finish raised face flanged
ends, 63-250 Ra finish
RFFE, 63-125 Ra finish raised face flanged
ends, 63-125 Ra finish
RFFE, 3 Ra finish
raised face flanged
ends, 3 Ra finish
RJFE
ring joint flanged
ends
@@SWE
socketwelded ends
@@FTE
female threaded ends
@@

S-5S
S-10S
S-40S
@@S-80S
S-10
S-20
S-30
S-40
S-60
S-80
S-100
S-120
S-140
@@S-160
@@bore

Sch 5S
Sch 10S
Sch 40S
Sch 80S
Sch 10
Sch 20
Sch 30
Sch 40
Sch 60
Sch 80
Sch 100
Sch 120
Sch 140
Sch 160
[???]

Plant Design System (PDS) Piping Component Data

553

Commodity Code Descriptions


W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

554

BA
BB
BC
BD
BQ
BR
BS
CA
CB
CC
CD
CE
CF
CG
CH
CI
CJ
CK
CL
CM
CN
CO
CP
CQ
CR
CS
CT
CU
CV
CW
CX
DD
DF
DH
DJ
DL
DN
EA
EB
EC
ED
EE

S-LW
S-STD
S-XS
@@S-XXS
@@CL3000
@@CL6000
@@CL9000
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.781 "
1.875 "
0.281 "
0.906 "
1.312 "
1.406 "
1.594 "
1.75 "
2 "
2.125 "
2.25 "
2.375 "
2.5 "

light-weight
standard-weight
X-strong
XX-strong
CL3000
CL6000
CL9000
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
1.375 "
1.5 "
1.625 "
1.781 "
1.875 "
0.281 "
0.906 "
1.312 "
1.406 "
1.594 "
1.75 "
2 "
2.125 "
2.25 "
2.375 "
2.5 "

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

EF
EH
FE
MA
MB
MC
MD
ME
MF
MG
MH
MI
MJ
MK
ML
MM
MN
MO
MP
MQ
MR
MS
MT
MU
MV
NP
NR
PA
PB
PC
PD
PE
PF
PG
PH
PI
PJ
PK
PL
PM
PN
PO

2.625 "
2.875 "
3.5 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
32.0 mm
45.0 mm
3.2 mm
4.8 mm
6.4 mm
7.9 mm
9.5 mm
11.1 mm
12.7 mm
14.3 mm
15.9 mm
17.5 mm
19.1 mm
20.6 mm
22.2 mm
23.8 mm
25.4 mm

2.625 "
2.875 "
3.5 "
2.0 mm
2.5 mm
3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
12.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
32.0 mm
45.0 mm (1.771) "
3.2 mm (0.125) "
4.8 mm (0.188) "
6.4 mm (0.25) "
7.9 mm (0.312) "
9.5 mm (0.375) "
11.1 mm (0.438) "
12.7 mm (0.5) "
14.3 mm (0.562) "
15.9 mm (0.625) "
17.5 mm (0.688) "
19.1 mm (0.75) "
20.6 mm (0.812) "
22.2 mm (0.875) "
23.8 mm (0.938) "
25.4 mm (1) "

Plant Design System (PDS) Piping Component Data

555

Commodity Code Descriptions


W
W
W
W
W
W
W
W
W
W
W
W
W
W

556

PP
PQ
PR
PS
PV
PW
PX
PZ
QA
QE
QF
QG
ZW
ZZ

W
W

AAA
AAB

AAC

AAD

W
W
W

AAG
AAH
AAI

AAJ

AAP

W
W
W
W
W
W
W

ABB
ABL
AFA
AFB
AFE
AFH
ASA

ASB

ASC

ASD

27.0 mm
28.6 mm
30.2 mm
31.8 mm
39.0 mm
56.0 mm
41.0 mm
29.0 mm
43.0 mm
47.0 mm
26.0 mm
19.0 mm
thk per reqn
@@

27.0 mm (1.062) "


28.6 mm (1.125) "
30.2 mm (1.188) "
31.8 mm (1.25) "
39.0 mm
56.0 mm (2.204) "
41.0 mm
29.0 mm
43.0 mm (1.692) "
47.0 mm
26.0 mm
19.0 mm
thk ??

@@ASTM-A234-WPB
ASTM-A234-WPB, alum

ASTM-A234 Gr.WPB
ASTM-A234 Gr.WPB,
aluminized per
ASTM-A676
ASTM-A234-WPB, galv
ASTM-A234 Gr.WPB,
galvanized
ASTM-A234-WPB T&W
ASTM-A234 Gr.WPB,
treated & wrapped
ASTM-A105, alum
ASTM-A105, aluminized
@@ASME-SA234-WPB
ASME-SA234 Gr.WPB
ASTM-A234-WPB
ASTM-A234 Gr.WPB,
fully stress relieved
ASTM-A234-WPB alum T&W ASTM-A234 Gr.WPB,
aluminized, treated &
wrapped
@@ASTM-A234-WPB
ASTM-A234 Gr.WPB
Dur-O-Lok
Dur-O-Lok fitting
ASTM-A350 LF2
ASTM-A350 Gr.LF2
@@ASTM-A420 WPL6
ASTM-A420 Gr.WPL6
@@ASTM-A105
ASTM-A105
@@ASTM-A350 LF2
ASTM-A350 Gr.LF2
@@ASME-SA105
ASME-SA105
ASTM-A105, galv
ASTM-A105, galvanized
ASTM-A234-WPB
ASTM-A234 Gr.WPB,
seamless
ASTM-A234-WPB, alum
ASTM-A234 Gr.WPB,
aluminized, per
ASTM-A676, seamless
ASTM-A234-WPB, galv
ASTM-A234 Gr.WPB,
galvanized, seamless
ASTM-A234-WPB T&W
ASTM-A234 Gr.WPB,
treated & wrapped,

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions

ASE

ASF

ASG

ASH

ASK

W
W

AZA
EAY

EAZ

EFA

ESA

W
W

FAC
FAF

W
W
W

FAH
FAL
FAM

W
W

FAT
FBD

W
W

FFC
FFE

FFF

FFI

W
W

FFL
FFR

W
W

FFT
FSA

FSB

FSC

seamless
ASME-SA234-WPB
ASME-SA234 Gr.WPB,
seamless
ASTM-A234-WPB alum T&W ASTM-A234 Gr.WPB,
aluminized, treated &
wrapped, seamless
ASTM-A420 WPL6
ASTM-A420 Gr.WPL6,
seamless
ASTM-A420-WPL6
ASTM-A420 Gr.WPL6
seamless, special
testing required
ASTM-A234-WPB
ASTM-A234 Gr.WPB,
seamless, special
testing required
@@carbon steel
carbon steel
ASTM-A234-WP1W
ASTM-A234 Gr.WP1W,
carbon moly
ASTM-A234-WP1
ASTM-A234 Gr.WP1,
carbon moly
ASTM-A182-F1
ASTM-A182 Gr.F1,
carbon moly
ASTM-A234-WP1
ASTM-A234 Gr.WP1,
carbon moly, seamless
@@ASTM-A234-WP11
ASTM-A234 Gr.WP11
ASTM-A234-WP22
ASTM-A234 Gr.WP22,
2.25Cr-1Mo
@@ASTM-A234-WP5
ASTM-A234 Gr.WP5
@@ASTM-A234-WP9
ASTM-A234 Gr.WP9
@@ASTM-A234-WP11
ASTM-A234 Gr.WP11
Dur-O-Lok
1.25Cr-0.5Mo Dur-O-Lok
fitting
ASTM-A182-F5
ASTM-A182 Gr.F5
ASTM-A336-F21
ASTM-A336 Gr.F21,
2.25Cr-1Mo
@@ASTM-A182-F11
ASTM-A182 Gr.F11
ASTM-A234-WP11W
ASTM-A234 Gr.WP11W,
1.25Cr-0.5Mo
ASTM-A182-F22
ASTM-A182 Gr.F22,
2.25Cr-1Mo
ASTM-A182-F5A
ASTM-A182 Gr.F5A,
5Cr-0.5Mo
@@ASTM-A182-F9
ASTM-A182 Gr.F9
ASTM-A182-F11
ASTM-A182 Gr.F11,
1.25Cr-0.5Mo
@@ASTM-A182-F5
ASTM-A182 Gr.F5
ASTM-A234-WP9
ASTM-A234 Gr.WP9,
9Cr-1Mo, seamless
ASTM-A234-WP11
ASTM-A234 Gr.WP11,
1.25Cr-0.5Mo, seamless
ASTM-A234-WP22
ASTM-A234 Gr.WP22,
2.25Cr-1Mo, seamless

Plant Design System (PDS) Piping Component Data

557

Commodity Code Descriptions

558

FSD

ASTM-A234-WP5

W
W
W

FZA
GAA
GAF

@@chrome steel
@@ASME-SA234-WP11
ASME-SA234-WP22

W
W

GFC
GFF

@@ASME-SA182-F11
ASME-SA182-F22

GSA

ASME-SA234-WP11

W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W

IFA
IFB
IFF
IFG
IFJ
IFL
IFY
IFZ
IIA
IIB
IIC
IID
IIE
IIF
IIG
IIH
IIJ
IIK
IIL
IIM
IIN
IIS
IIY
IIZ

@@ASTM-A182-F304
@@ASTM-A182-F304L
@@ASTM-A182-F316
ASTM-A182-F316L
@@ASTM-A182-F321
ASTM-A182-F347
ASTM-A182-F347H
ASTM-A182-F304H
ASTM-A403-WP304S
ASTM-A403-WP304LS
ASTM-A403-WP304LWX
ASTM-A403-WP304WX
ASME-SA403-WP316L
ASTM-A403-WP316S
ASTM-A403-WP316LS
ASTM-A403-WP316LWX
ASTM-A403-WP321S
ASTM-A403-WP316WX
ASTM-A403-WP347
ASTM-A403-WP321WX
ASTM-A403-WP347WX
ASTM-A403-WP304HWX
ASTM-A403-WP347H
ASTM-A403-WP304S

IKA

ASTM-A451-HF modified

W
W
W
W
W
W

IKB
IKD
IKE
IKF
IZA
OAA

@@ASTM-A403-WP304
@@ASTM-A403-WP304L
@@ASTM-A403-WP316
@@ASTM-A403-WP321
@@stainless steel
ASTM-B366-WPNIC,

ASTM-A234 Gr.WP5,
5Cr-0.5Mo, seamless
chrome alloy steel
ASME-SA234 Gr.WP11
ASME-SA234 Gr.WP22,
2.25Cr-1Mo
ASME-SA182 Gr.F11
ASME-SA182 Gr.F22,
2.25Cr-1Mo
ASME-SA234 Gr.WP11,
1.25Cr-0.5Mo, seamless
ASTM-A182 Gr.F304
ASTM-A182 Gr.F304L
ASTM-A182 Gr.F316
ASTM-A182 Gr.F316L
ASTM-A182 Gr.F321
ASTM-A182 Gr.F347
ASTM-A182 Gr.F347H
ASTM-A182 Gr.F304H
ASTM-A403 Gr.WP304S
ASTM-A403 Gr.WP304LS
ASTM-A403 Gr.WP304LWX
ASTM-A403 Gr.WP304WX
ASME-SA403 Gr.WP316L
ASTM-A403 Gr.WP316S
ASTM-A403 Gr.WP316LS
ASTM-A403 Gr.WP316LWX
ASTM-A403 Gr.WP321S
ASTM-A403 Gr.WP316WX
ASTM-A403 Gr.WP347
ASTM-A403 Gr.WP321WX
ASTM-A403 Gr.WP347WX
ASTM-A403 Gr.WP304HWX
ASTM-A403 Gr.WP347H
ASTM-A403 Gr.WP304S,
special testing
required
ASTM-A451 Gr.HF
modified, Spec 400-31
ASTM-A403 Gr.WP304
ASTM-A403 Gr.WP304L
ASTM-A403 Gr.WP316
ASTM-A403 Gr.WP321
stainless steel
ASTM-B366 Gr.WPNIC UNS

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions

OAB

OSA

OSB

PAA

PAB

PFA

SAA

SSA

WAA

WAB

WAC

WAD

WAE

WSA

WSB

WXX

___

Incoloy
ASTM-B564, Incoloy

N08800, Incoloy 800


ASTM-B564 UNS NO8800,
Incoloy
ASTM-B366-WPNIC,
ASTM-B366 Gr.WPNIC UNS
Incoloy
N08800, Incoloy 800,
seamless
ASTM-B564, Incoloy smls ASTM-B564 UNS NO8800,
Incoloy, seamless
ASTM-B366, Alloy 20
ASTM-B366 UNS NO8020,
Alloy 20 (wrought
fittings)
@@ASTM-B366-WPNC1 UNS ASTM-B366 Gr.WPNC1 UNS
N06600
N06600
ASTM-B462, Alloy 20
ASTM-B462 UNS NO8020,
Alloy 20 (forged
fittings)
ASTM-B361-WP6061-T6
ASTM-B361
Gr.WP6061-T6, aluminum
ASTM-B361-WP6061-T6
ASTM-B361
Gr.WP6061-T6, aluminum,
seamless
@@ASTM-A234-WPB,
ASTM-A234 Gr.WPB,
cement lined
cement lined
ASTM-A234-WPB, cement ASTM-A234 Gr.WPB,
lined & T&W
cement lined, treated &
wrapped
ASTM-A234-WPB, cement ASTM-A234 Gr.WPBW,
lined
cement lined
ASTM-A234-WPB, cement ASTM-A234 Gr.WPBW,
lined & T&C
cement lined, threaded &
coupled
ASTM-A234-WPB, cement ASTM-A234 Gr.WPBW,
lined & T&W
cement lined, treated &
wrapped
ASTM-A234-WPB, cement ASTM-A234 Gr.WPB,
cement lined, seamless
ASTM-A234-WPB, cement ASTM-A234 Gr.WPB,
lined & T&W
cement lined, treated &
wrapped, seamless
ASTM-A234-WPB
ASTM-A234 Gr.WPB,
epoxy lined
unspecified matl
matl specification to
be added later

Gaskets
! 0 1 2
! 1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
! FIRST LETTER: X - GASKETS
X A

@@Full face gasket

Full face gasket

Plant Design System (PDS) Piping Component Data

559

Commodity Code Descriptions


X B
X
X
X
X
X

Full plas gasket

Full face flat plastic


gasket
@@Ring gasket
Ring gasket
@@Spiral wound gasket
Spiral wound gasket
Serrated gasket
Serrated gasket
Corrugated gasket
Corrugated gasket
Double jkt gasket
Double jacketed
gasket
@@Double jacketed
Double jacketed
corrugated gasket
corrugated gasket
Envelope gasket
Envelope gasket
Plastic ring gasket
Flat plastic ring
gasket
Ring gasket
Ring gasket for plastic
lined pipe
@@Ring joint gasket, oval Ring joint gasket,
oval
Octagonal RJ gasket
Octagonal ring joint
gasket
Lens joint gasket
Lens joint gasket
Seal ring gasket
Seal ring gasket
Gasket per reqn
Gasket ??
Ring gasket per reqn
Ring gasket ??
Full face gasket per reqn Full face gasket ??
Vic gasket
Victaulic gasket

C
D
E
F
G

X H
X I
X J
X K
X L
X M
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

560

N
R
S
T
U
V
AA
AB
AC
AD
AE
AF
AG
AX
BA
BB
BC
BD
BE
BH
CA
CB
CD
CE
DA

@@ANSI-B16.5 CL150
@@ANSI-B16.5 CL300
ANSI-B16.5 CL400
@@ANSI-B16.5 CL600
@@ANSI-B16.5 CL900
@@ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
rating per reqn
@@API-605 CL150
@@API-605 CL300
API-605 CL400
API-605 CL600
API-605 CL900
API-605 CL75
@@MSS-SP-44 CL150
@@MSS-SP-44 CL300
@@MSS-SP-44 CL600
MSS-SP-44 CL900
ANSI-B16.1 CL25

ANSI-B16.5 CL150
ANSI-B16.5 CL300
ANSI-B16.5 CL400
ANSI-B16.5 CL600
ANSI-B16.5 CL900
ANSI-B16.5 CL1500
ANSI-B16.5 CL2500
rating ??
API-605 CL150
API-605 CL300
API-605 CL400
API-605 CL600
API-605 CL900
API-605 CL75
MSS-SP-44 CL150
MSS-SP-44 CL300
MSS-SP-44 CL600
MSS-SP-44 CL900
ANSI-B16.1 CL25

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

DB
DC
DD
SA
SB
SC
SD
SE
SF
SG
SH
TB
TC
TD
TE
TF
TG
ZZ

ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
@@CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
@@AWWA-C207 Cl.E
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350

ANSI-B16.1 CL125
ANSI-B16.1 CL250
ANSI-B16.1 CL800
CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
AWWA-C207 Cl.E
Taylor Forge CL75
Taylor Forge CL125
Taylor Forge CL125LW
Taylor Forge CL175
Taylor Forge CL250
Taylor Forge CL350

X
X
X
X
X

A
B
C
D
E

@@0.0625 thk "


@@0.125 thk "
0.1875 thk "
0.25 thk "
0.125 comp thk "

X
X
X
X
X
X
X

F
H
I
J
K
L
N

@@ANSI-B16.20
@@0.0625" thk
0.125 thk "
0.1875 thk "
0.25 thk "
0.5 thk "
1.6 mm thk

X
X
X
X
X
X
X
X
X
X

O
P
Q
R
S
T
U
V
X
Z

3.2
4.8
6.4
3.2
1.6
3.2
4.8
6.4
thk

0.0625 thk
0.125 thk
0.1875 thk API-601 "
0.25 thk "
0.125 compressed thk
API 601 "
ANSI-B16.20
0.0625" thk
0.125 thk "
0.1875 thk "
0.25 thk "
0.5 thk "
1.6 mm thk,
ANSI-B16.21
3.2 mm thk, API-601
4.8 mm thk, API-601
6.4 mm thk
3.2 mm thk, API 601
1.6 mm thk
3.2 mm thk
4.8 mm thk
6.4 mm thk
thk ??

mm thk
mm thk
mm thk
mm thk
mm thk
mm thk
mm thk
mm thk
per reqn

Plant Design System (PDS) Piping Component Data

561

Commodity Code Descriptions

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

562

AA
AB
AC
AD
AF
AG
AH
AI
AJ
AK
AL
AM
AN
AO
AW
BA
BB
BC
BD
CA
CB
CC
CD
CE
CF
CG
CH
CI
CJ
CK
CL
CM
CN
CO
CP
CQ
CR
CS
DD
MA
MB

S-5S
S-10S
S-40S
S-80S
S-10
S-20
S-30
S-40
S-60
S-80
S-100
S-120
S-140
S-160
[???]|bore to match|
S-LW
S-STD
S-XS
S-XXS
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
0.281 "
2.0 mm
2.5 mm

Sch 5S
Sch 10S
Sch 40S
Sch 80S
Sch 10
Sch 20
Sch 30
Sch 40
Sch 60
Sch 80
Sch 100
Sch 120
Sch 140
Sch 160
[???]
light-weight
standard-weight
X-strong
XX-strong
0.125 "
0.188 "
0.25 "
0.312 "
0.375 "
0.438 "
0.5 "
0.562 "
0.625 "
0.688 "
0.75 "
0.812 "
0.875 "
0.938 "
1 "
1.062 "
1.125 "
1.188 "
1.25 "
0.281 "
2.0 mm
2.5 mm

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

MC
MD
ME
MF
MG
MH
MI
MJ
MK
MM
MN
MO
MP
MQ
MR
MS
MT
MU
MV
PA
PB
PD
PE
PF
PG
PH
PI
PJ
PK
PL
PM
PN
PO
PP
PQ
PR
PS
ZZ

3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
3.2 mm
4.8 mm
6.4 mm
9.5 mm
11.1 mm
12.7 mm
14.3 mm
15.9 mm
17.5 mm
19.1 mm
20.6 mm
22.2 mm
23.8 mm
25.4 mm
27.0 mm
28.6 mm
30.2 mm
31.8 mm
@@

3.0 mm
3.5 mm
4.0 mm
4.5 mm
5.0 mm
6.0 mm
7.0 mm
8.0 mm
10.0 mm
16.0 mm
20.0 mm
25.0 mm
30.0 mm
35.0 mm
40.0 mm
50.0 mm
60.0 mm
80.0 mm
100.0 mm
3.2 mm (0.125) "
4.8 mm (0.188) "
6.4 mm (0.25) "
9.5 mm (0.375) "
11.1 mm (0.438) "
12.7 mm (0.5) "
14.3 mm (0.562) "
15.9 mm (0.625) "
17.5 mm (0.688) "
19.1 mm (0.75) "
20.6 mm (0.812) "
22.2 mm (0.875) "
23.8 mm (0.938) "
25.4 mm (1) "
27.0 mm (1.062) "
28.6 mm (1.125) "
30.2 mm (1.188) "
31.8 mm (1.25) "

X
X
X

AAA
AAB
AAC

low CS
low CS, 120 BHN max
@@5Cr-0.5Mo, 130 BHN max 5Cr-0.5Mo, 130 BHN max
347 SS
347 SS

Plant Design System (PDS) Piping Component Data

563

Commodity Code Descriptions

564

X
X
X
X
X

AAD
AAE
AAF
AAG
ALR

X
X
X
X

AZY
AZZ
HAA
HAB

ICA

ICB

ICC

ICD

ICE

LAA

LAB

X
X
X
X

PAA
PAD
PAE
PAF

QAB

QAC

QAD

QRB

QRC

QRF

QSA

12Cr TP410
321 SS
316 SS
@@347 SS, 140 BHN max
316 SS, special

12 chrome Type 410


321 SS
316 SS, 130-140 BHN
347 SS, 140 BHN max
316 SS, w/0.05% C max,
12% Ni min, 2.2% Mo min,
130-140 BHN
@@soft iron, 90 BHN max soft iron, 90 BHN max
soft steel
soft steel
Incoloy 800
Incoloy 800
@@Inconel 600, graph
Inconel 600, graphite
filled
filled
org fiber/SBR binder
organic fiber/SBR
binder Garlock Style
3400
org fiber/CR binder
organic fiber/neoprene
binder Garlock Style
3300
@@org fiber, nitrile
organic fiber, nitrile
binder
binder, ANSI-B16.21,
Garlock Style 3000
org fiber/EPDM binder
organic fiber/EPDM
binder Garlock Style
3700
org fiber/SBR binder
organic fiber/SBR
binder Garlock Style
3200
Grafoil/304
Grafoil, 304 SS wire
mesh inserted, Lamons
GHE
Grafoil/316
Grafoil, 316 SS mesh
tang inserted, Lamons
GHE
Viton
Viton
EPDM/Victaulic
EPDM Victaulic Gr.E
BUNA-N/Victaulic
BUNA-N Victaulic Gr.T
neoprene/Victaulic
neoprene Victaulic
Gr.V
Monel, TFE filled, Monel Monel, Teflon filled,
center ring
Monel center ring
Alloy 20/TFE CS center
Alloy 20, Teflon
ring
filled, CS center ring
neoprene sheet
neoprene sheet,
Manville Style 103C
316L/TFE CS center ring 316L SS, Teflon filled,
CS center ring
316/metal oval ring
316 SS, metal oval
ring
316L/graph filled, CS
316L SS, graphite
center ring
filled, CS center ring
304/mica/graph CS center 304 SS, mica/graphite

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


ring
304/mi/grph CS center
ring, 304 IR

QSB

QSC

QSD

QSF

@@304/Teflon-F, CS
center ring, 304 IR

QSG

QSH

QSJ

@@304/graph-F, CS center
ring
@@304/Teflon-F, CS
center ring
@@316/graph-F, CS center
ring, 316 IR

QSK

QSL

QSM

347/graph CS center ring

QSN

347/graph CS center ring,


347 IR

QSO

347/graph filled

QSP

Inconel/graph filled

QSS

304/graph CS center ring,


304 IR

QST

304/graph 304 center ring

QSU

304/graph 304 center


ring, 304 IR

QSV

347/graph 347 center ring

QSW

QSX

@@321/graph, CS center
ring
@@321/graph, CS center
ring, 321 IR

QUE

316/mica/graph CS center
ring
316/mi/grph CS center
ring, 316 IR

@@316/graph-F, CS center
ring
@@304/graph-F, CS center
ring, 304 IR

@@neoprene sheet

filled, CS center ring


304 SS, mica/graphite
filled, CS center ring &
304 SS inner ring
316 SS, mica/graphite
filled, CS center ring
316 SS, mica/graphite
filled, CS center ring &
316 SS inner ring
304 SS, Teflon filled,
CS center ring, 304 SS
inner ring
304 SS, graphite
filled, CS center ring
304 SS, Teflon filled,
CS center ring
316 SS, graphite
filled, CS center, 316
SS inner ring
316 SS, graphite
filled, CS center ring
304 SS, graphite
filled, CS center, 304
SS inner ring
347 SS, graphite
filled, CS center ring
347 SS, graphite
filled, CS center & 347
SS inner ring
347 SS, graphite
filled, Flexitallic
special Style R
Inconel, graphite
filled, 304 SS
inner/outer ring
304 SS, graphite
filled, CS gage & 304 SS
inner ring
304 SS, graphite
filled, 304 SS center
ring
304 SS, graphite
filled, 304 SS gage &
inner ring
347 SS, graphite
filled, 347 SS center
ring
321 SS, graphite
filled, CS center ring
321 SS, graphite
filled, CS center, 321
SS inner ring
neoprene sheet

Plant Design System (PDS) Piping Component Data

565

Commodity Code Descriptions

Bolting
!
!
!
Y

0 1 2
1 2345678901234567890 SHORT DESCRIPTION LONG DESCRIPTION
FIRST LETTER: Y - BOLTING
A
@@Bolt set for FFFE
Bolt set for flat face
joint
joint
B
@@Bolt set for RFFE
Bolt set for raised
joint
face joint
F
Bolt set for lap joint Bolt set for lap
joint
H
Jackscrew pair
Jackscrew pair
J
Bolt set for RJFE joint Bolt set for ring
joint flanged end
L
Bolt set for lens joint Bolt set for lens
joint
M
Miscellaneous
bolting
Z
@@

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

JA
JB
JC
JD
JE
JF
JG
JH
JI
JJ
JK
JL
JM
JN
JO
JP
JQ
JR
JS
JT
JU
JV
JW
JX

Y
Y
Y
Y
Y
Y

566

8 -0.5 diam "


@@8 -0.625 diam "
@@16 -0.625 diam "
@@16 -0.75 diam "
@@24 -0.75 diam "
16 -0.875 diam "
@@24 -0.875 diam "
@@24 -1 diam "
@@32 -1 diam "
24 -1.125 diam "
@@32 -1.125 diam "
@@40 -1.125 diam "
32 -1.25 diam "
@@40 -1.25 diam "
@@48 -1.25 diam "
@@56 -1.25 diam "
40 -1.375 diam "
40 -1.5 diam "
@@48 -1.5 diam "
@@64 -1.5 diam "
@@72 -1.5 diam "
@@88 -1.5 diam "
40 -1.625 diam "
48 -1.625 diam "

8 -0.5 diam "


8 -0.625 diam "
16 -0.625 diam "
16 -0.75 diam "
24 -0.75 diam "
16 -0.875 diam "
24 -0.875 diam "
24 -1 diam "
32 -1 diam "
24 -1.125 diam "
32 -1.125 diam "
40 -1.125 diam "
32 -1.25 diam "
40 -1.25 diam "
48 -1.25 diam "
56 -1.25 diam "
40 -1.375 diam "
40 -1.5 diam "
48 -1.5 diam "
64 -1.5 diam "
72 -1.5 diam "
88 -1.5 diam "
40 -1.625 diam "
48 -1.625 diam "

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

JY
JZ
KA
KB
KC
KD
KE
LA
ZZ
C

Y
Y
Y
Y
Y

64 -1.625 diam "


@@56 -1.75 diam "
88 -1.75 diam "
104 -1.75 diam "
48 -1.875 diam "
64 -1.875 diam "
@@64 -2 diam "
@@8 -1.25 diam "
@@
bolt hvy hex hd, w/nut

64 -1.625 diam "


56 -1.75 diam "
88 -1.75 diam "
104 -1.75 diam "
48 -1.875 diam "
64 -1.875 diam "
64 -2 diam "
8 -1.25 diam "

machine bolt hex


head, w/nut, heavy
series ANSI-B1.1
bolt hvy hex, w/nut
machine bolt hex
orifice
head, w/nut, heavy
series ANSI-B1.1
bolt hvy hex hd, w/o nut machine bolt hex
head, w/o nut, heavy
series ANSI-B1.1
stud, w/hvy hex nuts
studbolt, w/four hex
nuts, heavy series
ANSI-B1.1
stud, w/nut & 2 washers studbolt, w/two flat
washers & hex nuts,
heavy series
ANSI-B1.1
@@stud w/hvy hex nuts
studbolts w/hex nuts,
heavy series per
ANSI-B1.1
stud hvy hex nuts
studbolt, w/hex nuts,
orifice
heavy series
ANSI-B1.1
mach bolt hex hd, w/o nut machine bolt hex
head, w/flat washer,
w/o nut, heavy series
ANSI-B1.1
@@machine bolt hex hd
machine bolt hex head
w/nuts
w/nuts per ANSI-B1.1
@@cap screw hex head
cap screw hex head w/o
nut, heavy series per
ANSI-B1.1
hex nut, heavy series
hex nut heavy series
ANSI-B1.1

FA
FB
FC
FD
FE

1 lg "
1.25 lg "
@@1.5 lg "
@@1.75 lg "
@@2 lg "

Plant Design System (PDS) Piping Component Data

1 long "
1.25 long "
1.5 long "
1.75 long "
2 long "

567

Commodity Code Descriptions

568

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

FF
FG
FH
FI
FJ
FK
FL
FM
FN
FO
FP
FQ
FR
FS
FT
FU
FV
FX
FY
FZ
GA
GB
GC
GD
MC

@@2.25 lg "
@@2.5 lg "
@@2.75 lg "
@@3 lg "
@@3.25 lg "
@@3.5 lg "
@@3.75 lg "
@@4 lg "
@@4.25 lg "
@@4.5 lg "
4.75 lg "
5 lg "
@@5.25 lg "
5.5 lg "
@@5.75 lg "
6 lg "
@@6.25 lg "
@@6.5 lg "
6.75 lg "
7 lg "
7.25 lg "
7.5 lg "
7.75 lg "
8 lg "
+15 mm

MD

+20 mm

ME

+25 mm

MG

+40 mm

MI

+50 mm

ZZ

@@

AAA

AAB

Y
Y

AAW
AAX

2.25 long "


2.5 long "
2.75 long "
3 long "
3.25 long "
3.5 long "
3.75 long "
4 long "
4.5 long "
4 long "
4.5 long "
5 long "
5.25 long "
5.5 long "
5.75 long "
6 long "
6.25 long "
6.5 long "
6.75 long "
7 long "
7.25 long "
7.5 long "
7.75 long "
8 long "
plus 15 mm added
length
plus 20 mm added
length
plus 25 mm added
length
plus 40 mm added
length
plus 50 mm added
length

@@ASTM-A307-B w/A563-A
hvy hex nuts
ASTM-A307-B, w/A563-A
nuts
ASTM-A307-B
ASTM-A307-B

ASTM-A307 Gr.B w/A563


Gr.A hvy hex nuts
ASTM-A307 Gr.B w/A563
Gr.A nuts,
w/ASTM-B695, Cl.50
zinc coating
ASTM-A307 Gr.B
ASTM-A307 Gr.B, w/o
nuts, w/ASTM-B695,
Cl.50 zinc coating

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


Y

FFB

@@ASTM-A193-B8C Cl.1
w/A194-8C hv hx nuts

FFC

ASTM-A193-B7, w/A194-2H
nuts, cad plated

FFD

@@ASTM-A193-B8C Cl.1
w/A194-8C hv hx nuts

FFF

@@ASTM-A193-B7
w/A194-2H hvy hex nts

FFG

ASTM-A193-B7

FFL

@@ASTM-A193-B7M
w/A194-2H hvy hex nuts

FFM

ASTM-A193-B7M,
w/A194-2HM hvy hex nuts

FFN

ASTM-A193-B7M,
w/A194-2H hvy hex nuts

FFO

ASTM-A193-B7M,
w/A194-2HM hvy hex nuts

Y
Y

FFP
FFT

@@ASTM-A193-B7M
ASTM-A193-B7, w/A194-2H
hvy hex nuts

FFU

ASTM-A193-B8 Cl.2,
w/A194-8 hvy hex nuts

FFV

ASTM-A193-B8 Cl.2,
w/A194-8 hvy hex nuts

Y
Y

FFW
FFX

@@ASTM-A193-B7
ASTM-A193-B8 Cl.2

FFY

ASTM-A193-B8 Cl.2

FFZ

FGT

ASTM-A193-B8C
Cl.2,w/A194-8C hvy hex
nuts
ASTM-A193-B16, w/A194-3

Plant Design System (PDS) Piping Component Data

ASTM-A193 Gr.B8C Cl.1


w/A194 Gr.8C hvy hex
nuts
ASTM-A193 Gr.B7,
w/A194 Gr.2H hvy hex
nuts, 300 BHN max,
cadmium plated
ASTM-A193 Gr.B8C Cl.1
w/A194 Gr.8C hvy hex
nuts, Electofilm 2006
coated
ASTM-A193 Gr.B7
w/A194 Gr.2H hvy hex
nuts
ASTM-A193 Gr.B7,
Electrofilm 2006
coated
ASTM-A193 Gr.B7M
w/A194 Gr.2H hvy hex
nuts
ASTM-A193 Gr.B7M,
w/A194 Gr.2HM hvy hex
nuts
ASTM-A193 Gr.B7M,
w/A194 Gr.2H hvy hex
nuts, Electrofilm 2006
coated
ASTM-A193 Gr.B7M,
w/A194 Gr.2HM hvy hex
nuts, Electrofilm 2006
coated
ASTM-A193 Gr.B7M
ASTM-A193 Gr.B7,
w/ASTM-A194 Gr.2H hvy
hex nuts, Electrofilm
2006 coated
ASTM-A193 Gr.B8 Cl.2,
w/A194 Gr.8 hvy hex
nuts
ASTM-A193 Gr.B8 Cl.2,
w/A194 Gr.8 hvy hex
nuts, Electrofilm 2006
coated
ASTM-A193 Gr.B7
ASTM-A193 Gr.B8 Cl.2,
w/o nuts
ASTM-A193 Gr.B8 Cl.2,
w/o nuts Electrofilm
2006 coated
ASTM-A193 Gr.B8C
Cl.2, w/ASTM-A194
Gr.8C hvy hex nuts
ASTM-A193 Gr.B16,

569

Commodity Code Descriptions


hvy hex nuts
Y

FGU

@@ASTM-A193-B16
w/A194-4 hvy hex nuts

Y
FGV

ASTM-A193-B16, w/A194-3
hvy hex nuts

Y
Y

FYF
GGC

ASTM-A194-2H
@@ASME-SA193-B7
w/SA194-2H hvy hex nuts

GGD

ASME-SA193-B7,
w/SA194-2H hvy hex nuts

GGE

ASME-SA193-B16,
w/SA194-3 hvy hex nuts

VGGF

570

@@ASME-SA193-B16
w/SA194-4 hvy hex nuts

GGG

ASME-SA193-B16,
w/SA194-3 hvy hex nuts
ASTM-A453-660 Cl.B

IIA

ILU

@@ASTM-A320-B8 Cl.2,
w/A194-8 hvy hx nuts

ILV

ASTM-A320-B8 Cl.2,
w/A194-8 hvy hex nuts

Y
Y

ILW
ILX

ASTM-A320-B8 Cl.2
ASTM-A320-B8 Cl.2

MLF

@@ASTM-A320-L7 w/A194-4
hvy hex nuts

Y
Y

MLG
MLH

@@ASTM-A320-L7
ASTM-A320-L7

MLT

ASTM-A320-L7, w/A194-4
hvy hex nuts

w/A194 Gr.3 hvy hex


nuts, Electrofilm 2006
coated
ASTM-A193 Gr.B16
w/A194 Gr.4 hvy hex
nuts, Electrofilm 2006
coated
ASTM-A193 Gr.B16,
w/ASTM-A194 Gr.3 hvy
hex nuts
ASTM-A194 Gr.2H
ASME-SA193 Gr.B7
w/SA194 Gr.2H hvy hex
nuts
ASME-SA193 Gr.B7,
w/SA194 Gr.2H hvy hex
nuts, Electrofilm 2006
coated
ASME-SA193 Gr.B16,
w/SA194 Gr.3 hvy hex
nuts, Electrofilm 2006
coated
ASME-SA193 Gr.B16
w/SA194 Gr.4 hvy hex
nuts, Electrofilm 2006
coated
ASME-SA193 Gr.B16,
w/SA194 Gr.3 nuts
ASTM-A453 Gr.660 Cl.B
nuts, Electrofilm 2006
coated
ASTM-A320 Gr.B8 Cl.2
w/A194 Gr.8 hvy hex
nuts
ASTM-A320 Gr.B8 Cl.2,
w/A194 Gr.8 hvy hex
nuts, Electrofilm 2006
coated
ASTM-A320 Gr.B8 Cl.2
ASTM-A320 Gr.B8 Cl.2,
Electrofilm 2006
coated
ASTM-A320 Gr.L7
w/A194 Gr.4 hvy hex
nuts
ASTM-A320 Gr.L7
ASTM-A320 Gr.L7,
Electrofilm 2006
coated
ASTM-A320 Gr.L7,
w/A194 Gr.4 hvy hex
nuts, Electrofilm 2006
coated

Plant Design System (PDS) Piping Component Data

Commodity Code Descriptions


Y

OAA

ASTM-B164

Plant Design System (PDS) Piping Component Data

ASTM-B164 Monel UNS


NO4400

571

APPENDIX E

Calculations From ANSI-B31.1 and


ANSI-B31.3
These equations define formulas for the calculation of piping wall thickness and branch
reinforcement to resist positive pressure.

Delivered Equations
The thickness and branch reinforcement logic for the following equations are hardcoded in the
software.
EJ01
Source - ANSI-B31.1.1986 [Power Piping]
Thickness logic from paragraph 104.1, equation 3
Reinforcement logic from paragraph 104.3.1(D)

EL01
Source - ANSI-B31.3c.1986 [Chemical Plant and Petroleum Refinery Piping]
Thickness logic from paragraph 304.1, equation 3a
Reinforcement logic from paragraph 304.3.3 & Code - Appendix H

The following considerations apply to both thickness equations and branch reinforcement
calculations.
Pressures and temperatures used in thickness/branch reinforcement calculations are derived
from data in the Piping Design Database. Both normal and alternate pressure and
temperature conditions are considered. If actual values exist for the normal design or the
alternate design pressure/temperatures, the corresponding operating conditions are ignored.
If default values exist for BOTH sets of design conditions, both normal and alternate operating
conditions are used. At least one complete set of conditions must be defined.
Once the proper pressure and temperature sets are determined, their units of measure are
converted to those used in the Temperature-Pressure Table associated with the Piping

Plant Design System (PDS) Piping Component Data

573

Calculations From ANSI-B31.1 and ANSI-B31.3

Materials Class to which the component belongs. Conversions are performed using the
procedures and conversion factors defined for the Units of Measure in Appendix F.
Only positive pressure is considered. The system reports an error if you request a thickness
calculation involving a vacuum condition (negative pressure).
Independent sets of thickness/reinforcement calculations are carried out for each applicable
pressure/temperature set. In each calculation set, table values that are temperature
dependent are determined on the basis of the temperature applicable to the calculation set
being considered. The thicker calculated thickness is used.

Thickness Equations
The following considerations apply to thickness equations.
Thickness calculations are triggered by specifying an equation name in the
Schedule/Thickness attribute of the Piping Commodity Specification Data. An asterisk (*)
followed by a name (of the form xyyy) defines the specific calculation or table lookup to be
used for wall thickness. The letters that form this code have the following meaning:
x alphanumeric code that defines the equation to use in the calculation. Possible values
and their definitions are:
If this character is C, the schedule/thickness for the applicable end of the component is
determined by calculations using the thickness equation defined in the
DEFAULT_WALL_THICK_EQUATION attribute of the Piping Materials Class database
table.
If the code is any character other than C, the schedule/thickness for the applicable end of
the component is determined by calculations using the thickness equation with the name
EX.
yyy casting, joint or structural grade quality factor (E) times 100.
This factor is one of the parameters used in the thickness calculation. If you are defining a
calculation to be performed on a seamless fitting (E=1) but want to match the thickness for the
mating welded pipe (E=0.85), the quality factor for the pipe should be entered here.
For components with ends having different nominal diameters, independent sets of thickness
determinations are performed for each NPD. One or more ends may need to calculated, as
determined by specific *xyyy entries in the Commodity Item entity. The larger thickness
(calculated or predefined) is used. For example:
A 20" x 10" reducer is defined in the Piping Commodity Table to have a *xyyy 20" end and
a 0.55" thick, 10" end. The calculation of the 20" end results in a 0.5" thickness. A 0.55"
thick reducer is used.
A 24" x 20" reducer is defined in the Piping Commodity Table to have a *XYYY 24" end
and a *XYYY 20" end. The calculation of the 24" end results in a 0.6" thickness. The
calculation of the 20" end results in a 0.5" thickness. A 0.6" thick reducer is used.
All thickness calculations involve a casting, joint, or structural grade quality factor (E).
The value for this factor is YYY/100, where YYY is defined in the entry *XYYY made under
the Schedule Thickness attribute for the Commodity Item under consideration.

Branch Reinforcement
The following considerations apply to branch reinforcement calculations.
The need to perform a branch reinforcement calculation is triggered by
the placement of a generic branch component with the actual item name determined from
a branch table. (See Branch Insertion Tables.)

574

Plant Design System (PDS) Piping Component Data

Calculations From ANSI-B31.1 and ANSI-B31.3

the presence of more than one item name in the Preferred Branch AABBCC Codes fields
of the applicable branch table.
the applicable branch reinforcement being either a reinforcing weld or a reinforcing pad.
All calculations involve a casting, joint, or structural grade quality factor (E). The value for this
factor is YYY/100, where YYY is defined in the Modifier attribute for entries with an item name
of PIPING.
The fillet welds joining reinforcing pads to the header and to the branch are considered in
determining the available reinforcement area.

Spec Access
The execution of a pipe wall thickness calculation is performed when the variable PIPE_OD_n is
encountered in the physical data definition of a pipe or component. Therefore, pipe outside
diameter must be calculated or retrieved from a table before the wall thickness can be used as
part of a table name.
After the actual thickness is calculated, it is compared against the thickness range in the Materials
table and the retirement thickness in the Thickness Data table. The system uses the greater of
these values as the uncorroded wall thickness. Then the system adds the corrosion allowance
from the PMC, the thread thickness from the wall thickness table, and the mill tolerance from the
Materials table. This revised thickness is compared against the minimum thickness value in the
Thickness Data table. The larger of these two values is compared against the preferred
thickness value in the Thickness Data table, and the next largest preferred value is used for table
look-ups and is stored in the TDB.
If the Thickness Data table uses schedules as preferred thickness, the schedules are translated to
an actual thickness by a table look-up from a table of the form
MALWT//Term_type//shc_thick//generic_flag//weight_code
and output 2 gives the actual wall thickness.

Verification of Schedule Thickness


You can set an option in the RDB to determine how the piping segment override
schedule/thickness value will be handled during wall thickness calculations. By default, the piping
segment schedule/thickness override is used in place of the value determined from the Piping Job
Specification.

Plant Design System (PDS) Piping Component Data

575

APPENDIX F

Codelists
This section details the codelists used in PDS.
The data contained within this appendix is for informational purposes only and may not
exactly match the codelists delivered with the product.

Plant Design System (PDS) Piping Component Data

577

Codelists
In This Appendix
General Comments ........................................................................ 579
Comments Specific to Units of Measure Codelist Sets ................. 579
CL31, Object Types for Orthographic Drawings (40) .................... 581
CL35, Approval Status (10) ........................................................... 583
CL36, Structural Approval Status (15) ........................................... 583
CL37, HVAC Approval Status (10) ................................................ 584
CL50, Hold Status (10) .................................................................. 584
CL69, Equipment Divisions/Form Code (99) ................................. 584
CL125, Fluid Code/Connector Type (999) ..................................... 585
CL130, Construction Status (15) ................................................... 589
CL145, Materials Grade (4500) ..................................................... 589
CL148, Piping Materials Class Description (31999) ...................... 625
CL160, Responsibility (25)............................................................. 636
CL180, Fabrication Category (99) ................................................. 636
CL190, Coating Requirements (99) ............................................... 637
CL200, Heat Tracing Requirements (10)....................................... 637
CL210, Heat Tracing Media (60) ................................................... 638
CL220, Insulation Purpose (40) ..................................................... 639
CL230, Cleaning Requirements (99) ............................................. 639
CL330, CP Type/Termination/Preparation (999) ........................... 639
CL332, Schedule / Thickness Override ......................................... 643
CL340, Safety Classification (99) .................................................. 645
CL360, Stress Analysis Requirements (15) ................................... 645
CL365, Reporting Requirements (25) ............................................ 645
CL366, Requirement to Reconstruct (10) ...................................... 646
CL380, Piping Component Type (2500) ........................................ 646
CL390, Action (40) ......................................................................... 655
CL400, Option (999) ...................................................................... 655
CL420, Piping Component Type/Source (25)................................ 664
CL425, Piping/Tubing Type (25) .................................................... 664
CL430, Instrument Component Type/Source (25)......................... 664
CL499, Piping Notes (999) ............................................................ 664
CL530, Accessory/Item Type (125) ............................................... 667
CL550, Operator/Actuator Type (200) ........................................... 667
CL570, Design Standard (200) ...................................................... 669
CL572, Wall Thickness Equation ................................................... 669
CL575, Geometry Standard (31999) ............................................. 669
CL576, Table Suffix/End Standard - Green (999) ......................... 684
CL577, Table Suffix/End Standard - Red (999) ............................. 688
CL578, Weight Code (399) ............................................................ 692
CL990, Types of Piping Commodity Data Forms .......................... 694
CL999, Standard Note Title (2000) ................................................ 695
CL1010, Area Units (25) ................................................................ 696
CL1028, Mass Units (40) ............................................................... 697
CL1056, Temperature Units (15) ................................................... 697
CL1064, Pressure Units (40) ......................................................... 698
CL1074, Density Units (35)............................................................ 699
CL1100, Weld Type (100).............................................................. 699
CL1162, Force Units (40) .............................................................. 699
CL1201, Drawing Scale (540)........................................................ 700
CL1202, Drawing Size (199).......................................................... 700

578

Plant Design System (PDS) Piping Component Data

Codelists
CL1203, Interference Manager Approval Status (99) .................... 700
CL1204, Interference Clash Type .................................................. 700
CL1205, Interference Manager Action (10) ................................... 703
CL1207, Interference Manager Approval Method (10) .................. 703
CL1208, Clash Checking Option ................................................... 703
CL1209, Clash Checking Volume Filter Option ............................. 703
CL1310, Report Source (99).......................................................... 703
CL1312, Report Type (999) ........................................................... 703
CL1410, Design Review Type (10) ................................................ 704
CL1605, Model Status ................................................................... 704
CL1610, Force Units for FrameWorks Plus (40) ........................... 704
CL1620, Drawing View Directions (7) ............................................ 705
CL1630, Drawing View Composition Status (4) ............................ 705
CL1710, Document Source (99) .................................................... 705
CL1720, Document Type (999) ..................................................... 706
CL1900, Isometric Drawing Type .................................................. 708
CL2000, PD_Draw Document Type (999) ..................................... 709

General Comments
Codelist sets in this document define the values for all codelisted attributes used in the PDS Piping
Task which are specific to US plant design practices.
You can add, delete, or revise codelists sets to reflect your own practices, terminology and
language. A task user, however, cannot revise a codelist set from a work session. Revisions to
a codelist set, can only be made in the General RDB or Standard Note Library.
In listings that follow, the maximum number of entries that may be expected for a specific codelist
set is shown in parenthesis following the name of the codelist set.
For PDS users that wish to modify codelist files delivered with the PDS software to reflect their
own practices, two approaches are possible:
Make the modifications within the range of codelist numbers defined in the codelist library
delivered with the PDS software. This has the advantage of resulting in the best-organized
set of codelisted definitions. The disadvantage is that numbers added by the User may
conflict with numbers added in future versions of software.
Increase the maximum number of entries allowed for the codelist set and make additions to it
in the range of extended numbers. This will minimize possible conflicts assigned numbers
but will require compiling of the codelists and of the associated databases.
Values enclosed in brackets [ ] in pages that follow represent descriptive information. The values
stored in the codelist sets will exclude this bracketed information from the codelist descriptions.
The net length of a codelist entry cannot exceed 50 characters. Other considerations may,
however, require that a shorter description be made. For example:
For the P&ID Task, the total compressed length of a label part can not exceed 36 characters.
The formats of specification type reports for the Instrument Task require that applicable
codelist descriptions do not exceed 25 characters.

Comments Specific to Units of Measure Codelist Sets


The PDS system of units is derived from the 1980 Edition of API-2564, Manual of Petroleum
Measurement Standards, Chapter 15 "Guidelines for the Use of the International System of Units
(SI) in the Petroleum and Allied Industries".

Plant Design System (PDS) Piping Component Data

579

Codelists
The tables in this document include the following information.
Codelist set

This is the number of the codelist set that identifies a specific


quantity. For example, codelist set 1028 includes the units of
measure that apply tothe quantity "mass".

Codelist no

This is the number that defines a specific unit of measure within a


codelist set. For example, codelist number 1 in codelist set 1028
refers to the "lb" units of measure.

Unit type

This code is not explicitly shown in the tables. The unit type equals
the number of the codelist set minus 1000. For example, reference
to unit type 28 refers to "mass".

Quantity name

Entries in this column define the quantity whose units of measure


are being defined.

Unit name:

Several unit names are provided for a given codelist set. Any of
these names can be used to define the quantity.

Conversion to
destination unit:

Two sets of columns define the conversion of variables expressed


in the units shown under the column Unit Name" to the unit shown
under the "column "Destination Unit". The following explanations
apply:
The following explanations apply:
The column captioned Destination Unit defines the unit to which the unit included under the
column Unit Name will be converted using the value shown under the column Factor.
The column captioned Factor provides the actual conversion factor to be used for the
conversion. For example, in codelist set 1028, to convert a mass measurement in "lb" to "kg",
multiply the value in the former units by the conversion factor, 4.535 924 E-01. In some
cases, such as temperature, summation may also be required to effect the desired
conversion. All conversion factors are taken or derived from API Publication 2564. Groups
of three digits are separated by spaces with no commas. For example,
3.048 000 E-01 = 3.048 000 x 10^-1 = 0.3048000.
Similarly,
9.290 304 E+02 = 9.290 304 x 10^2 = 929.0304.
An asterisk (*) indicates that all following digits are zeros. If a conversion factor happens to end
in several zeros but does not have an asterisk, any subsequent digits would not necessarily be
zeros. Most of the conversion factors are shown to six or seven significant figures. Those
shown to fewer than six significant figures are limited by the precision of the known or
determinable value of a physical property, such as the density of distilled water at a reference
temperature.
Conversion to first unit in Two sets of columns define the conversion of the units shown
CL:
under the column Unit Name to the first unit shown in that
column. The conversion is done per the equation:
y= A + Bx
where,
x applies to the value of the variable expressed in the units shown in the column captioned Unit
Name.
y applies to the value of the variable expressed in the units shown in the first line of the column
captioned Unit Name.
A is the factor in the column captioned Factor A.

580

Plant Design System (PDS) Piping Component Data

Codelists
B is the factor in the column captioned Factor B.
The distinction between upper case and lower case symbols is very important. For example:
K= kelvin
k= kilo= 10^3
M= mega= 10^6
m= milli= 10^-3 (when m is used as a prefix)
m= metre (when m is used alone)
N= newton
n= nano= 10^-9
In editing any of the codelist sets for units, do not change the meaning of existing codelist values.
In all codelist sets for units, a blank space is provided as the first character in the unit name. The
blank space is used to silence the units in the formation of labels.
Nomenclature:
Symbol

Name

Quantity

bar

bar

pressure

degC

degree
Celsius

temperature

gram

mass

kg

kilogram

mass

metre

length

min

minute

time

Pa

pascal

pressure

metric ton

mass

CL31, Object Types for Orthographic Drawings (40)


C31 DF='WRK_DD_CODLST:CODE0031.ENT' MAX=999
0031, Object Types for Orthographic Drawings (40)
Equipment Category Object Types (100-149)
The Range of 100-149 for the equipment category is
divided into two parts:
101-110 These entries are reserved by INTERGRAPH
and may not be changed by the user.
111-149 Codelist entries in this range may be created,
revised, and/or deleted by the user.
If modified the user must also revise the
contents of the file eqp_object.dwg and
labels.xxx (where xxx is the drawing type
number defined in CL2000 ) in the project
directory.

Plant Design System (PDS) Piping Component Data

581

Codelists
101
110
120
124
128
130
135
140

=
=
=
=
=
=
=
=

Piping
205
207
210
215
220

=
=
=
=
=

'Equipment
'Equipment
'Equipment
'Equipment
'Equipment
'Equipment
'Equipment
'Equipment

Group'
Nozzle'
Platform'
Handrail'
Penetration'
Stair'
Ladder'
Davit'

Category Object Types (200-249)


'Piping
'Pipe'
'Piping
'Piping
'Piping

Segment'
Component'
Specialty'
Support'

Instrument Category Object Types (250-279)


250
252
255
260

=
=
=
=

'Control Valves and Regulators'


'Relief Devices'
'Other In-Line Instruments'
'Off-Line Instruments'

HVAC Category Object Types (359-399)


359
360
361
362
363
364
365
366
367
368
369
370
371

=
=
=
=
=
=
=
=
=
=
=
=
=

'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC
'HVAC

Coil Data'
Connector Data'
Damper Data'
Diffuser Data'
Duct Data'
DEquipment Data'
Filter Data'
Fitting Data'
Grille Data'
Hood Data'
Humidifier Data'
Register Data'
Terminal Devices'

EERWAY Category Object Types (300-306)


300
301
302
303
304
305
306
307
308

582

=
=
=
=
=
=
=
=
=

'EERWAY
'EERWAY
'EERWAY
'EERWAY
'EERWAY
'EERWAY
'EERWAY
'EERWAY
'EERWAY

Connect Point'
OneLine'
Straight'
Fitting'
Space Envelope'
To_Equipment'
To_Support'
Eqp Panel'
Duct Bank'

Plant Design System (PDS) Piping Component Data

Codelists

CL35, Approval Status (10)


In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
The following are the requirements in use of the "approval status."
2
3
11-20
21-30

reserved
reserved
reserved
reserved

for
for
for
for

'approved'
'not approved'
'approved'
'not approved'

1 = [Blank]
2 = 'A =Approved'
3 = 'NA=Not approved'

CL36, Structural Approval Status (15)


In editing this codelist
of existing codelist values.
values to the left of the "="
that only values to the right
0
1
2
3
4

=
=
=
=
=

set, do not change the meaning


Some data displays require that only
sign be shown; other reports require
of the "=" sign be displayed.

'New'
'Existing'
'Future'
'User 1'
'User 2'

Plant Design System (PDS) Piping Component Data

583

Codelists

CL37, HVAC Approval Status (10)


In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1
2
3
4

=
=
=
=

'New'
'Existing'
'Dismantle'
'Future'

CL50, Hold Status (10)


In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed. Labels
always require that only values to the right of the "=" sign be displayed.
1 = 'NH=Not held'
2 = 'H =Hold'

CL69, Equipment Divisions/Form Code (99)


In editing this codelist set, do not change the meaning
of codelist value "All". Some data displays require that only
values to the left of the "=" sign be shown; other data displays
require that only values to the right of the "=" sign be displayed.
1
2
3
4
5
6
7
8

584

=
=
=
=
=
=
=
=

'A=
'B=
'C=
'D=
'E=
'F=
'H=
'I=

All'
Vessels'
Heat transfer'
Mechanical'
Civil/Structural'
Piping'
Electrical'
Other'

Plant Design System (PDS) Piping Component Data

Codelists

CL125, Fluid Code/Connector Type (999)


In editing this codelist set, do not change the meaning
of existing codelist values 950-999.
1 = [Blank]
11
14
17
20
23
26
29
32
35
40

=
=
=
=
=
=
=
=
=
=

'A'
'AC'
'AE'
'AI'
'AO'
'AP'
'APU'
'AR'
'AS'
'AZ'

[Air]
[Combustion air]
[Aeration air]
[Instrument air]
[Operational air]
[Plant air]
[Purge air]
[Regeneration air]
[Starting air]
[Other air]

71
75
79
83
87
91
100

=
=
=
=
=
=
=

'C'
'CA'
'CE'
'CF'
'CLP'
'CPR'
'CZ'

[Refrigerant]
[Ammonia refrigerant]
[Ethylene refrigerant]
[Freon refrigerant]
[LP refrigerant]
[Propylene refrigerant]
[Other refrigerant]

101
103
105
107
109
111
113
115
117
119
121
123
125
127
128
130

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'D'
'DC'
'DCH'
'DGR'
'DOW'
'DP'
'DPH'
'DS'
'DSP'
'DST'
'DW'
'DWS'
'DX'
[Blank]
[Blank]
'DZ'

[Sewer]
[Caustic sewer]
[Chemical sewer]
[Drain to grade]
[Oily water sewer]
[Process sewer]
[Heated process sewer]
[Sanitary sewer]
[Press sanitary sewer]
[Storm sewer]
[Clean water sewer]
[Sour water sewer]
[Acid sewer]
[Storm, oily water or sanitary sewer]
[Storm or oily water sewer]
[Other sewer]

161 = 'F'

[Foam]

Plant Design System (PDS) Piping Component Data

585

Codelists

586

191
194
197
198
200
203
206
209
212
215
218
221
224
227
230
233
236
239
242
245
250

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'G'
'GCD'
'GCL'
'GCN'
'GF'
'GG'
'GH'
'GHS'
'GI'
'GLP'
'GM'
'GN'
'GNI'
'GOX'
'GP'
'GR'
'GS'
'GSO'
'GSW'
'GW'
'GZ'

[Gas]
[Carbon dioxide gas]
[Chlorine gas]
[Chlorination gas]
[Fuel gas]
[Flue gas]
[Hydrogen gas]
[Hydrogen sulphide gas]
[Inert gas]
[LP gas]
[Make-up gas]
[Natural gas]
[Nitrogen gas]
[Oxygen gas]
[Purge gas]
[Reformed gas]
[Synthesis gas]
[Sour gas]
[Sweet gas]
[Waste gas
[Other gas]

341
346
351
356
370

=
=
=
=
=

'K'
'KG'
'KF'
'KD'
'KZ'

[Solvent]
[Glycol]
[Furfural]
[Dewaxing]
[Other solvent]

401
402
405
409
413
417
421
425
429
433
434
440
444
448
452
460

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'M'
[Blank]
'MAA'
'MAC'
'MAW'
'MC5'
'MCL'
'MEO'
'MHC'
'MIA'
'MIB'
'MLA'
'MMA'
'MS'
'MSL'
'MZ'

[Chemical]
[Chemical injection]
[Anhydrous ammonia]
[Aluminum chloride]
[Aqueous ammonia]
[0-50% caustic solution]
[Dry chlorine]
[Ethylene oxide]
[Hydrogen chloride]
[Inhibitor A]
[Inhibitor B]
[Lube oil additives]
[Methyl alcohol]
[Sulfur]
[Liquid sulfur]
[Other chemical]

Plant Design System (PDS) Piping Component Data

Codelists
491
493
495
497
499
500
503
505
507
509
511
513
515
520

=
=
=
=
=
=
=
=
=
=
=
=
=
=

'O'
'OD'
'ODS'
'OF'
'OFR'
'OFS'
'OH'
'OL'
'OLS'
'OS'
'OSO'
'OSW'
'OWS'
'OZ'

[Oil]
[Diesel fuel oil]
[Dry slop oil]
[Flushing oil]
[Fuel oil return]
[Fuel oil supply]
[Hydraulic oil]
[Lube]
[Lube and seal oil]
[Seal oil]
[Sour oil]
[Sweet oil]
[Wet slop oil]
[Other oil]

521
522
524
527
530
533
536
539
542
545
550

=
=
=
=
=
=
=
=
=
=
=

'P'
[Blank]
'PA'
'PAS'
'PB'
'PH'
'PHH'
'PHW'
'PL'
'PS'
'PZ'

[Process]
[Special process]
[Process w/ rich/lean amine]
[Process w/ severe amine]
[Process w/ benzene]
[Process w/ H2]
[Process w/ H2 & H2S]
[Process w/ aqueous H2S]
[Low temperature process]
[Process w/ S]
[Other process]

581 = 'RA'
591 = 'RF'
610 = 'RZ'

[Relief to atmosphere]
[Relief to flare]
[Other relief]

611
613
615
617
621
623
625
627
629
631
633
635
640

=
=
=
=
=
=
=
=
=
=
=
=
=

'S'
[Blank]
[Blank]
[Blank]
'SE'
'SH'
'SL'
'SM'
'SN'
'SS'
'SV'
'SX'
'SZ'

[Steam]
[Boiler feed water or steam]
[Boiler feed water, steam or condensate]
[Steam or condensate]
[Extr press CL1500 steam]
[High press CL900 steam]
[Low press CL150 steam]
[Med press CL600 steam]
[Nor press CL300 steam]
[Superheated steam]
[Vacuum steam]
[Exhaust CL125 steam]
[Other steam]

641
643
645
647
649
651
653
655
660

=
=
=
=
=
=
=
=
=

'SC'
'SCA'
'SCE'
'SCH'
'SCL'
'SCM'
'SCN'
'SCV'
'SCZ'

[Steam condensate]
[Atmospheric CL125 steam condensate]
[Extr press CL1500 steam condensate]
[High press CL900 steam condensate]
[Low press CL150 steam condensate]
[Med press CL600 steam condensate]
[Nor press CL300 steam condensate]
[Vacuum steam condensate]
[Other steam condensate]

Plant Design System (PDS) Piping Component Data

587

Codelists

588

721
731
741
750
751
753
755
757
759
761
763
764
765
767
768
771
772
773
775
777
779
781
783
785
786
789
791
792
795
797
798
801
803
805
807
809
811
812
815
817
819
830

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'V'
'VA'
'VF'
'VZ'
'W'
'WB'
'WBA'
'WBB'
'WC'
[Blank]
'WCH'
'WCL'
'WCF'
'WCR'
'WCS'
'WPT'
[Blank]
'WDM'
'WFA'
'WFI'
'WFU'
'WG'
'WGL'
'WGR'
'WGS'
'WH'
'WHR'
'WHS'
'WI'
'WIR'
'WIS'
'WK'
'WN'
'WP'
'WR'
'WS'
'WSR'
'WSS'
'WT'
'WU'
'WW'
'WZ'

[Vent]
[Vent to atmosphere]
[Vent to flare]
[Other vent]
[Water]
[Boiler feed water]
[Ballast water]
[Water boiler blowdown]
[Cooling water]
[Cooling or utility water]
[Chlorinated water]
[Chlorine in water]
[Clarified water]
[Cooling water return]
[Cooling water supply]
[Potable water]
[Potable water or instrument air]
[Demineralized water]
[Aboveground fire water]
[Filtered water]
[Underground fire water]
[Glycol water]
[Gland water]
[Glycol water return]
[Glycol water supply]
[Hot water]
[Hot water return]
[Hot water supply]
[Chilled water]
[Chilled water return]
[Chilled water supply]
[Treated water]
[Brine water]
[Process water]
[Raw water]
[Sea water]
[Sea water return]
[Sea water supply]
[Test water]
[Utility water]
[Waste water]
[Other water]

831
835
839
843
847
851
853
860

=
=
=
=
=
=
=
=

'X'
'XH'
'XN'
'XSD'
'XS3'
'XS8'
'XS9'
'XZ'

[Acid]
[Hydrofluoric acid]
[Nitric acid]
[Dilute sulfuric acid]
[30% sulfuric acid]
[75-80% sulfuric acid]
[93-97% sulfuric acid]
[Other acid]

Plant Design System (PDS) Piping Component Data

Codelists
861
865
869
873
877
881
890

=
=
=
=
=
=
=

'Y'
'YA'
'YG'
'YH'
'YL'
'YW'
'YZ'

[Catalyst]
[Catalyst addition]
[General catalyst]
[Catalyst w/ H2]
[Catalyst lift lines]
[Catalyst withdrawal lines]
[Other catalyst]

950
951
953
955
956
960
961
999

=
=
=
=
=
=
=
=

'ODPC'
'OUPC'
'UODPC'
'ODIC'
'OUIC'
'OVPC'
'OSPC'
'TERM'

[Off-dwg piping connectors]


[Off-unit piping connectors]
[Utility off-dwg piping connectors]
[Off-dwg instr connectors]
[Off-unit instr connectors]
[Off-vol piping connectors]
[Off-site piping connectors]
[Terminator piping connector]

CL130, Construction Status (15)


In editing this codelist set, do not change the meaning
of existing codelist values 2, 3 and 8. In addition, codelist
values 4-7 must imply an "existing" construction status. Codelist
values 9-15 inherit the color symbology from the construction
status of the item previously placed in the model.
1
2
3
4
5
6
7
8

=
=
=
=
=
=
=
=

[Blank]
'New'
'Existing'
'Revamp'
'Relocate'
'Temporary'
'Dismantle'
'Future'

CL145, Materials Grade (4500)


Some data displays require that only values to the left of the
"=" sign be shown; other reports require that only values to the right
of the "=" sign be displayed.
1 = [Blank]

Plant Design System (PDS) Piping Component Data

589

Codelists
Irons,
10 =
12 =
15 =
16 =
17 =
18 =
19 =
20 =
21 =
22 =
23 =
25 =
30 =
31 =
32 =
35 =
40 =
41 =
42 =
43 =
44 =
45 =
46 =
47 =
48 =
55 =
60 =
62 =
70 =
75 =
76 =

590

10-99
'A47-32510'
'A47-35018'
'A48-20'
'A48-25'
'A48-30'
'A48-35'
'A48-40'
'A48-45'
'A48-50'
'A48-55'
'A48-60'
'A74'
'A126-A'
'A126-B'
'A126-C'
'A197'
'A278-20'
'A278-25'
'A278-30'
'A278-35'
'A278-40'
'A278-50'
'A278-60'
'A278-70'
'A278-80'
'A338'
'A395-Ductile'
'A395-Ferritic Ductile'
'A571'
'AWWA-C110-Ductile'
'AWWA-C151-Ductile'

Plant Design System (PDS) Piping Component Data

Codelists
Carbon
110 =
114 =
116 =
118 =
120 =
122 =
124 =
135 =
140 =
142 =
144 =
150 =
160 =
162 =
164 =
170 =
180 =
182 =
183 =
184 =
185 =
186 =
187 =
188 =
190 =
191 =
192 =
193 =
194 =
195 =
200 =
202 =
210 =
212 =
214 =
216 =
218 =
220 =
230 =
234 =
240 =
241 =
242 =
243 =
244 =
245 =
250 =
252 =
254 =
264 =
266 =
270 =
272 =

Steels, 100-499
'API-5L-A'
'API-5L-A25'
'API-5L-B'
'API-5L-X42'
'API-5L-X46'
'API-5L-X52'
'API-5L-X65'
'A36'
'A53-A'
'A53-B'
'A53-Type F'
'A105'
'A106-A'
'A106-B'
'A106-C'
'A120'
'A134-A36'
'A134-A283-A'
'A134-A283-B'
'A134-A283-C'
'A134-A283-D'
'A134-A285-A'
'A134-A285-B'
'A134-A285-C'
'A134-A570-30'
'A134-A570-33'
'A134-A570-36'
'A134-A570-40'
'A134-A570-45'
'A134-A570-50'
'A135-A'
'A135-B'
'A139-A'
'A139-B'
'A139-C'
'A139-D'
'A139-E'
'A179'
'A181-CL60'
'A181-CL70'
'A211-A570-30'
'A211-A570-33'
'A211-A570-36'
'A211-A570-40'
'A211-A570-45'
'A211-A570-50'
'A216-WCA'
'A216-WCB'
'A216-WCC'
'A234-WPB'
'A234-WPC'
'A283-A'
'A283-B'

Plant Design System (PDS) Piping Component Data

591

Codelists
274
276
280
282
284
290
293
295
298
300
302
305
310
312
320
321
322
323
325
327
334
340
342
344
346
350
352
354
356
360
361
362
363
364
365
370
372
375
380
390
392
394
396
398
400
402
404
406
408
410
420
422
424
426

592

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'A283-C'
'A283-D'
'A285-A'
'A285-B'
'A285-C'
'A333-1'
'A333-6'
'A334-1'
'A334-6'
'A350-LF1'
'A350-LF2'
'A352-LCB'
'A369-FPA'
'A369-FPB'
'A381-Y35'
'A381-Y42'
'A381-Y46'
'A381-Y48'
'A381-Y50'
'A381-Y52'
'A420-WPL6'
'A515-55'
'A515-60'
'A515-65'
'A515-70'
'A516-55'
'A516-60'
'A516-65'
'A516-70'
'A520-30'
'A520-33'
'A520-36'
'A520-40'
'A520-45'
'A520-50'
'A524-I'
'A524-II'
'A537-CL1'
'A587'
'A671-CA55'
'A671-CB60'
'A671-CB65'
'A671-CB70'
'A671-CC60'
'A671-CC65'
'A671-CC70'
'A671-CD70'
'A671-CE55'
'A671-CE60'
'A671-CK75'
'A672-A45'
'A672-A50'
'A672-A55'
'A672-B55'

Plant Design System (PDS) Piping Component Data

Codelists
428
430
432
434
436
438
440
442
444
446
448
460
464

=
=
=
=
=
=
=
=
=
=
=
=
=

'A672-B60'
'A672-B65'
'A672-B70'
'A672-C55'
'A672-C60'
'A672-C65'
'A672-C70'
'A672-D70'
'A672-E55'
'A672-E60'
'A672-N75'
'A691-CMS75'
'A691-CMSH70'

Plant Design System (PDS) Piping Component Data

593

Codelists
Low and Intermediate Alloy Steels, 500-899
510 = 'A182-F1'
512 = 'A182-F2'
514 = 'A182-F5'
516 = 'A182-F5a'
518 = 'A182-F6a Cl.1'
519 = 'A182-F6a Cl.2'
520 = 'A182-F6a Cl.3'
521 = 'A182-F6a Cl.4'
523 = 'A182-F6b'
524 = 'A182-F7'
526 = 'A182-F9'
528 = 'A182-F11'
530 = 'A182-F12'
532 = 'A182-F21'
534 = 'A182-F22'
536 = 'A182-F22a'
540 = 'A202-A'
542 = 'A202-B'
550 = 'A203-A'
552 = 'A203-B'
554 = 'A203-D'
556 = 'A203-E'
560 = 'A204-A'
562 = 'A204-B'
564 = 'A204-C'
576 = 'A217-C5'
578 = 'A217-C12'
580 = 'A217-CA15'
582 = 'A217-WC1'
584 = 'A217-WC4'
586 = 'A217-WC5'
588 = 'A217-WC6'
590 = 'A217-WC9'
600 = 'A225-A'
602 = 'A225-B'
610 = 'A234-WP1'
614 = 'A234-WP5'
616 = 'A234-WP7'
618 = 'A234-WP9'
620 = 'A234-WP11'
622 = 'A234-WP12'
624 = 'A234-WP22'
630 = 'A302-A'
632 = 'A302-B'
634 = 'A302-C'
636 = 'A302-D'
644 = 'A333-3'
646 = 'A333-4'
648 = 'A333-7'
650 = 'A333-8'
652 = 'A333-9'
664 = 'A334-3'
666 = 'A334-7'

594

Plant Design System (PDS) Piping Component Data

Codelists
668
670
680
682
684
686
687
690
692
694
696
698
700
702
710
720
722
724
730
740
742
744
746
748
750
752
754
756
758
760
761
770
771
774
775
778
779
780
781
782
783
784
785
786
787
794
798
800
802
804
806
808
810
812

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'A334-8'
'A334-9'
'A335-P1'
'A335-P2'
'A335-P5'
'A335-P5b'
'A335-P5c'
'A335-P7'
'A335-P9'
'A335-P11'
'A335-P12'
'A335-P15'
'A335-P21'
'A335-P22'
'A350-LF3'
'A352-LC1'
'A352-LC2'
'A352-LC3'
'A353'
'A369-FP1'
'A369-FP2'
'A369-FP3b'
'A369-FP5'
'A369-FP7'
'A369-FP9'
'A369-FP11'
'A369-FP12'
'A369-FP21'
'A369-FP22'
'A385-7 Cl.1'
'A385-7 Cl.2'
'A387-2 Cl.1'
'A387-2 Cl.2'
'A387-5 Cl.1'
'A387-5 Cl.2'
'A387-9 Cl.1'
'A387-9 Cl.2'
'A387-11 Cl.1'
'A387-11 Cl.2'
'A387-12 Cl.1'
'A387-12 Cl.2'
'A387-21 Cl.1'
'A387-21 Cl.2'
'A387-22 Cl.1'
'A387-22 Cl.2'
'A420-WPL3'
'A420-WPL8'
'A426-CP1'
'A426-CP2'
'A426-CP5'
'A426-CP5b'
'A426-CP7'
'A426-CP9'
'A426-CP11'

Plant Design System (PDS) Piping Component Data

595

Codelists
814
816
817
820
822
830
832
835
840
842
850
852
854
860
862
864
866
868
870
872
874
876
878

596

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'A426-CP12'
'A426-CP15'
'A426-CPCA15'
'A426-CP21'
'A426-CP22'
'A553-Type I'
'A553-Type II'
'A645'
'A671-CF70'
'A671-CF71'
'A672-L65'
'A672-L70'
'A672-L75'
'A691-CM65'
'A691-CM70'
'A691-CM75'
'A691-0.5Cr'
'A691-1Cr'
'A691-1.25Cr'
'A691-2.25Cr'
'A691-3Cr'
'A691-5Cr'
'A691-9Cr'

Plant Design System (PDS) Piping Component Data

Codelists
Stainless Steels, 900-1324
920 = 'A167-301'
922 = 'A167-302'
923 = 'A167-302B'
926 = 'A167-304'
927 = 'A167-304L'
930 = 'A167-305'
932 = 'A167-308'
934 = 'A167-309'
935 = 'A167-309S'
938 = 'A167-310'
939 = 'A167-310S'
942 = 'A167-316'
943 = 'A167-316L'
946 = 'A167-317'
947 = 'A167-317L'
950 = 'A167-321'
952 = 'A167-347'
954 = 'A167-348'
960 = 'A182-F10'
964 = 'A182-F304'
965 = 'A182-F304H'
966 = 'A182-F304L'
968 = 'A182-F310'
970 = 'A182-F316'
971 = 'A182-F316H'
972 = 'A182-F316L'
974 = 'A182-F321'
975 = 'A182-F321H'
978 = 'A182-F347'
979 = 'A182-F347H'
982 = 'A182-F348'
983 = 'A182-F348H'
990 = 'A240-X8M'
992 = 'A240-302'
994 = 'A240-304'
995 = 'A240-304L'
996 = 'A240-304H'
998 = 'A240-305'
1000 = 'A240-309S'
1004 = 'A240-310S'
1006 = 'A240-316'
1007 = 'A240-316L'
1010 = 'A240-317'
1011 = 'A240-317L'
1014 = 'A240-321'
1016 = 'A240-347'
1018 = 'A240-348'
1020 = 'A240-405'
1022 = 'A240-410'
1023 = 'A240-410S'
1026 = 'A240-429'
1028 = 'A240-430'
1040 = 'A268-TP329'

Plant Design System (PDS) Piping Component Data

597

Codelists
1044
1046
1048
1050
1051
1054
1056
1060
1061
1064
1065
1066
1070
1071
1072
1074
1076
1078
1079
1080
1082
1084
1085
1088
1089
1092
1095
1100
1102
1104
1106
1108
1110
1112
1113
1114
1116
1118
1120
1122
1124
1126
1128
1130
1140
1141
1144
1146
1148
1149
1152
1154
1156
1160

598

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'A268-TP405'
'A268-TP409'
'A268-TP410'
'A268-TP430'
'A268-TP430Ti'
'A268-TP443'
'A268-TP446'
'A269-TP304'
'A269-TP304L'
'A269-TP316'
'A269-TP316L'
'A270-TP316L'
'A312-TP304'
'A312-TP304H'
'A312-TP304L
'A312-TP309'
'A312-TP310'
'A312-TP316'
'A312-TP316H'
'A312-TP316L'
'A312-TP317'
'A312-TP321'
'A312-TP321H'
'A312-TP347'
'A312-TP347H'
'A312-TP348'
'A351-CA15'
'A351-CF3'
'A351-CF3A'
'A351-CF3M'
'A351-CF8'
'A351-CF8A'
'A351-CF8C'
'A351-CF8M'
'A351-CF10'
'A351-CF10MC'
'A351-CN7M'
'A351-CH8'
'A351-CH10'
'A351-CH20'
'A351-CK20'
'A351-HK30'
'A351-HK40'
'A351-HT30'
'A358-304'
'A358-304L'
'A358-309S'
'A358-310S'
'A358-316'
'A358-316L'
'A358-321'
'A358-347'
'A358-348'
'A376-16-8-2H'

Plant Design System (PDS) Piping Component Data

Codelists
1162
1163
1166
1167
1170
1171
1174
1175
1178
1179
1190
1191
1192
1194
1196
1198
1199
1200
1202
1204
1205
1206
1207
1210
1220
1222
1224
1226
1228
1230
1232
1234
1240
1241
1244
1245
1248
1249
1252
1253
1260
1262
1264
1266
1268
1270
1272
1280
1282
1284
1300

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'A376-TP304'
'A376-TP304H'
'A376-TP316'
'A376-TP316H'
'A376-TP321'
'A376-TP321H'
'A376-TP347'
'A376-TP347H'
'A376-TP348'
'A376-TP348H'
'A403-WP304'
'A403-WP304H'
'A403-WP304L'
'A403-WP309'
'A403-WP310'
'A403-WP316'
'A403-WP316H'
'A403-WP316L'
'A403-WP317'
'A403-WP321'
'A403-WP321H'
'A403-WP347'
'A403-WP347H'
'A403-WP348'
'A409-TP304'
'A409-TP309'
'A409-TP310'
'A409-TP316'
'A409-TP317'
'A409-TP321'
'A409-TP347'
'A409-TP348'
'A430-FP304'
'A430-FP304H'
'A430-FP316'
'A430-FP316H'
'A430-FP321'
'A430-FP321H'
'A430-FP347'
'A430-FP347H'
'A451-CHP10'
'A451-CHP20'
'A451-CPF8C'
'A451-CPF8M'
'A451-CPF10MC'
'A451-CPH8'
'A451-CPK20'
'A452-TP304H'
'A452-TP316H'
'A452-TP347H'
'ASME SA479-316L'

Plant Design System (PDS) Piping Component Data

599

Codelists
Copper
1325 =
1330 =
1331 =
1334 =
1335 =
1338 =
1339 =
1342 =
1346 =
1350 =
1354 =
1356 =
1358 =
1362 =
1363 =
1364 =
1368 =
1369 =
1370 =
1374 =
1375 =
1376 =
1380 =
1381 =
1382 =
1386 =
1387 =
1392 =
1393 =
1398 =
1399 =
1404 =
1408 =
1410 =
1412 =
1414 =
1416 =
1418 =
1422 =
1430 =
1432 =
1434 =
1436 =
1438 =
1440 =
1442 =
1450 =
1452 =
1456 =
1458 =
1462 =
1463 =
1466 =

600

and Copper Alloys, 1325-1549


'AISI-CDA Alloy 377'
'B42 Cl.C10200, drwn, NPD 0.0625-2'
'B42 Cl.C10200, drwn, NPD 2.5-12'
'B42 Cl.C12000, drwn, NPD 0.0625-2'
'B42 Cl.C12000, drwn, NPD 2.5-12'
'B42 Cl.C12200, drwn, NPD 0.0625-2'
'B42 Cl.C12200, drwn, NPD 2.5-12'
'B43 Cl.C23000, annld'
'B61 Cl.C92200'
'B62 Cl.C83600'
'B68 Cl.C10200, annld'
'B68 Cl.C12000, annld'
'B68 Cl.C12200, annld'
'B75 Cl.C10200, annld'
'B75 Cl.C10200, hrd drwn'
'B75 Cl.C10200, light drwn'
'B75 Cl.C12000, annld'
'B75 Cl.C12000, hrd drwn'
'B75 Cl.C12000, light drwn'
'B75 Cl.C12200, annld'
'B75 Cl.C12200, hrd drwn'
'B75 Cl.C12200, light drwn'
'B75 Cl.C14200, annld'
'B75 Cl.C14200, hrd drwn'
'B75 Cl.C14200, light drwn'
'B88 Cl.C10200, annld'
'B88 Cl.C10200, drwn'
'B88 Cl.C12000, annld'
'B88 Cl.C12000, drwn'
'B88 Cl.C12200, annld'
'B88 Cl.C12200, drwn'
'B96 Cl.C65500, annld'
'B152 Cl.C10200, annld'
'B152 Cl.C10400, annld'
'B152 Cl.C10500, annld'
'B152 Cl.C10700, annld'
'B152 Cl.C12200, annld'
'B152 Cl.C12300, annld'
'B169 Cl.C61400, soft'
'B283 Cl.C11000'
'B283 Cl.C37700'
'B283 Cl.C46400'
'B283 Cl.C48500'
'B283 Cl.C63900'
'B283 Cl.C65500'
'B283 Cl.C67500'
'B402 Cl.C70600, annld'
'B402 Cl.C71500, annld'
'B466 Cl.C70600, annld'
'B466 Cl.C71500, annld'
'B467 Cl.C70600, annld, <=4.5in OD'
'B467 Cl.C70600, annld, >4.5in OD'
'B467 Cl.C71500, annld, <=4.5in OD'

Plant Design System (PDS) Piping Component Data

Codelists
1467
1472
1474
1476
1478
1480
1482
1484
1486
1488
1490
1492
1494
1496
1498
1500
1502

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'B467
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584
'B584

Cl.C71500, annld, >4.5in OD'


Cl.C86200'
Cl.C86300'
Cl.C86400'
Cl.C86500'
Cl.C86700'
Cl.C90300'
Cl.C90500'
Cl.C92200'
Cl.C92300'
Cl.C95200'
Cl.C95300'
Cl.C95500'
Cl.C95600'
Cl.C97300'
Cl.C97600'
Cl.C97800'

Plant Design System (PDS) Piping Component Data

601

Codelists
Nickel
1560 =
1561 =
1564 =
1565 =
1568 =
1572 =
1573 =
1574 =
1576 =
1577 =
1578 =
1582 =
1586 =
1587 =
1590 =
1591 =
1594 =
1595 =
1596 =
1600 =
1601 =
1604 =
1605 =
1606 =
1607 =
1610 =
1611 =
1614 =
1615 =
1616 =
1620 =
1624 =
1626 =
1628 =
1630 =
1632 =
1634 =
1636 =
1638 =
1642 =
1643 =
1646 =
1648 =
1650 =
1652 =
1654 =
1656 =
1658 =
1660 =
1664 =
1666 =
1670 =
1672 =

602

and Nickel Alloys 1550-1774


'B127-400 (N04400) hot rolled plt annld'
'B127-400 (N04400) hot rolled plt AR'
'B160-200 (N02200) annld'
'B160-200 (N02200) hot fin'
'B160-201 annld'
'B161-200 (N02200) annld, <=5in OD'
'B161-200 (N02200) annld, >5in OD'
'B161-200 (N02200) stress rlvd'
'B161-201 (N02201) annld, <=5in OD'
'B161-201 (N02201) annld, >5in OD'
'B161-201 (N02201) stress rlvd'
'B162-200 (N02200) hot rolled plt annld'
'B162-201 (N02201) hot rolled plt annld'
'B162-201 (N02201) hot rolled plt AR'
'B164-400 (N04400) annld forged'
'B164-400 (N04400) hot fin'
'B165-400 (N04400) annld, <=5in OD'
'B165-400 (N04400) annld, >5in OD'
'B165-400 (N04400) stress rlvd'
'B166-600 (N06600) annld'
'B166-600 (N06600) hot fin'
'B167-600 (N06600) cold drwn annld, <=5in OD'
'B167-600 (N06600) cold drwn annld, >5in OD'
'B167-600 (N06600) hot fin/hot fin annld, <=5in OD'
'B167-600 (N06600) hot fin/hot fin annld, >5in OD'
'B168-600 (N06600) hot rolled plt annld'
'B168-600 (N06600) hot rolled plt AR'
'B333-B (N10001) sln annld plt'
'B333-B (N10001) sln annld sheet'
'B333-B-2 (N10665) sln annld'
'B335-B-2 (N10665) sln annld'
'B366-WPHB (N10001)'
'B366-WPHX (N06002)'
'B366-WPN (N02200)'
'B366-WPNC (N04400)'
'B366-WPNC1 (N06600)'
'B366-WPNL (N02201)'
'B366-WPNLWX'
'B366-WPNWX'
'B407-800 (N08800) cold drwn annld'
'B407-800 (N08800) hot fin/hot fin annld'
'B407-800H (N08810) cold drwn sln annld/hot fin'
'B443-625 (N06625) annld'
'B444-625 (N06625) annld'
'B446-625 (N06625) annld'
'B464-20Cb (N08020) annld'
'A494-CW-12M-1'
'A494-CW-12M-2'
'A494-CY-40'
'B574-C-4 (N06455) sln annld'
'B574-C-276 (N10276) sln annld'
'B575-C-4 (N06455) sln annld'
'B575-C-276 (N10276) sln annld'

Plant Design System (PDS) Piping Component Data

Codelists
1676
1680
1684
1688
1700
1702
1704
1706
1708
1710
1714
1718
1722
1724
1726
1728
1730
1732

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'B581-G (N06007) sln annld'


'B582-G (N06007) sln annld'
'B612-200 (N02200) hot rolled plt AR'
'B619-20-Mod (N08320) sln annld'
'B619-B (N10001) sln annld'
'B619-B-2 (N10665) sln annld'
'B619-C-4 (N06455) sln annld'
'B619-C-276 (N10276) sln annld'
'B619-G1 (N06007) sln annld'
'B619-X (N06002) sln annld'
'B620-20-Mod (N08320) sln annld'
'B621-20-Mod (N08320) sln annld'
'B622-B (N10001) sln annld'
'B622-B-2 (N10655) sln annld'
'B622-C-4 (N06455) sln annld'
'B622-C-276 (N10276) sln annld'
'B622-G (N06007) sln annld'
'B622-X (N06002) sln annld'

Plant Design System (PDS) Piping Component Data

603

Codelists
Aluminum Alloys 1775-2299
1780 = 'B26-356.0 temper T6'
1782 = 'B26-356.0 temper T71'
1784 = 'B26-443.0 temper F'
1790 = 'B209-1060 temper 0'
1792 = 'B209-1060 temper H12'
1794 = 'B209-1060 temper H14'
1796 = 'B209-1060 temper H112'
1798 = 'B209-1100 temper 0'
1800 = 'B209-1100 temper H12'
1802 = 'B209-1100 temper H14'
1804 = 'B209-1100 temper H112'
1806 = 'B209-3003 temper 0'
1808 = 'B209-3003 temper H12'
1810 = 'B209-3003 temper H14'
1812 = 'B209-3003 temper H112'
1814 = 'B209-3004 temper 0'
1816 = 'B209-3004 temper H32'
1818 = 'B209-3004 temper H34'
1820 = 'B209-3004 temper H112'
1822 = 'B209-5050 temper 0'
1824 = 'B209-5050 temper H32'
1826 = 'B209-5050 temper H34'
1828 = 'B209-5050 temper H112'
1830 = 'B209-5052 temper 0'
1832 = 'B209-5052 temper H32'
1834 = 'B209-5052 temper H34'
1836 = 'B209-5052 temper H112'
1838 = 'B209-5652 temper 0'
1840 = 'B209-5652 temper H32'
1842 = 'B209-5652 temper H34'
1844 = 'B209-5652 temper H112'
1846 = 'B209-5083 temper 0'
1848 = 'B209-5083 temper H321'
1850 = 'B209-5086 temper 0'
1852 = 'B209-5086 temper H32'
1854 = 'B209-5086 temper H34'
1856 = 'B209-5086 temper H112'
1858 = 'B209-5154 temper 0'
1860 = 'B209-5154 temper H32'
1862 = 'B209-5154 temper H34'
1864 = 'B209-5154 temper H112'
1866 = 'B209-5254 temper 0'
1868 = 'B209-5254 temper H32'
1870 = 'B209-5254 temper H34'
1872 = 'B209-5254 temper H112'
1874 = 'B209-5454 temper 0'
1876 = 'B209-5454 temper H32'
1878 = 'B209-5454 temper H34'
1880 = 'B209-5454 temper H112'
1882 = 'B209-5456 temper 0'
1884 = 'B209-5456 temper H321'
1886 = 'B209-6061 temper T4'
1888 = 'B209-6061 temper T4, wld'

604

Plant Design System (PDS) Piping Component Data

Codelists
1890
1892
1894
1896
1898
1900
1902
1904
1906
1908
1910
1912
1914
1916
1918
1920
1922

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'B209-6061 temper
'B209-6061 temper
'B209-6061 temper
'B209-Alclad 3003
'B209-Alclad 3003
'B209-Alclad 3003
'B209-Alclad 3003
'B209-Alclad 3004
'B209-Alclad 3004
'B209-Alclad 3004
'B209-Alclad 3004
'B209-Alclad 6061
'B209-Alclad 6061
'B209-Alclad 6061
'B209-Alclad 6061
'B209-Alclad 6061
'B209-Alclad 6061

T6'
T6, wld'
T651'
temper 0'
temper H12'
temper H14'
temper H112'
temper 0'
temper H32'
temper H34'
temper H112'
temper T4'
temper T4, wld'
temper T6'
temper T6, wld'
temper T451'
temper T651'

Plant Design System (PDS) Piping Component Data

605

Codelists
1930
1932
1934
1936
1938
1940
1942
1944
1946
1948
1950
1952
1954
1956
1958
1960
1962
1964
1966
1968
1970
1972
1974
1976
1978
1980
1982
1984
1986
1988
1990
1992
1994
2010
2012
2014
2016
2018
2020
2022
2024
2026
2028
2030
2032
2034
2036
2038
2040
2042
2044
2046
2048
2050

606

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'B210-1060 temper
'B210-1060 temper
'B210-1060 temper
'B210-3003 temper
'B210-3003 temper
'B210-3003 temper
'B210-3003 temper
'B210-5052 temper
'B210-5052 temper
'B210-5052 temper
'B210-5083 temper
'B210-5083 temper
'B210-5086 temper
'B210-5086 temper
'B210-5086 temper
'B210-5086 temper
'B210-5154 temper
'B210-5154 temper
'B210-5456 temper
'B210-5456 temper
'B210-6061 temper
'B210-6061 temper
'B210-6061 temper
'B210-6061 temper
'B210-6063 temper
'B210-6063 temper
'B210-6063 temper
'B210-6063 temper
'B210-6063 temper
'B210-Alclad 3002
'B210-Alclad 3003
'B210-Alclad 3003
'B210-Alclad 3002
'B221-1060 temper
'B221-1060 temper
'B221-1100 temper
'B221-1100 temper
'B221-3003 temper
'B221-3003 temper
'B221-5052 temper
'B221-5053 temper
'B221-5086 temper
'B221-5154 temper
'B221-5454 temper
'B221-5456 temper
'B221-6061 temper
'B221-6061 temper
'B221-6061 temper
'B221-6061 temper
'B221-6063 temper
'B221-6063 temper
'B221-6063 temper
'B221-6063 temper
'B221-6063 temper

0'
H14'
H112'
0'
H14'
H18'
H112'
0'
H32'
H34'
0'
H112'
0'
H32'
H34'
H112'
0'
H34'
0'
H112'
T4'
T4, wld'
T6'
T6, wld'
T4'
T4, wld'
T5, wld'
T6'
T6, wld'
temper 0'
temper H14'
temper H18'
temper H112'
0'
H112'
0'
H112'
0'
H112'
0'
0'
0'
0'
0'
0'
T4'
T4, wld'
T6'
T6, wld'
T4'
T4, wld'
T5'
T5, wld'
T6'

Plant Design System (PDS) Piping Component Data

Codelists
2052
2054
2056
2070
2072
2074
2076
2078
2080
2082
2084
2086
2088
2090
2092
2094
2096
2098
2100
2102
2104
2106
2108
2110
2112
2114
2116
2118
2120
2122
2124
2126
2128
2130
2140
2142
2144
2146
2148
2150
2152
2160
2162
2164
2166
2168
2170
2172
2174
2176
2178
2180
2182
2184

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'B221-6063 temper
'B221-Alclad 3003
'B221-Alclad 3003
'B241-1060 temper
'B241-1060 temper
'B241-1100 temper
'B241-1100 temper
'B241-3003 temper
'B241-3003 temper
'B241-3003 temper
'B241-5052 temper
'B241-5083 temper
'B241-5083 temper
'B241-5086 temper
'B241-5086 temper
'B241-5454 temper
'B241-5454 temper
'B241-5456 temper
'B241-5456 temper
'B241-5462 temper
'B241-5462 temper
'B241-6061 temper
'B241-6061 temper
'B241-6061 temper
'B241-6061 temper
'B241-6061 temper
'B241-6063 temper
'B241-6063 temper
'B241-6063 temper
'B241-6063 temper
'B241-6063 temper
'B241-6063 temper
'B241-Alclad 3003
'B241-Alclad 3003
'B247-3003 temper
'B247-3003 temper
'B247-5083 temper
'B247-5083 temper
'B247-5083 temper
'B247-6061 temper
'B247-6061 temper
'B345-1060 temper
'B345-1060 temper
'B345-3003 temper
'B345-3003 temper
'B345-3003 temper
'B345-5083 temper
'B345-5083 temper
'B345-5086 temper
'B345-5086 temper
'B345-6061 temper
'B345-6061 temper
'B345-6061 temper
'B345-6061 temper

T6, wld'
temper 0'
temper H112'
0'
H112'
0'
H112'
0'
H18'
H112'
0'
0'
H112'
0'
H112'
0'
H112'
0'
H112'
0'
H112'
T4'
T4, wld'
T6, <NPD 1'
T6, =>NPD 1'
T6, wld'
T4'
T4, wld'
T5'
T5, wld'
T6'
T6, wld'
temper 0'
temper H112'
H112'
H112, wld'
0'
H112'
H112, wld'
T6'
T6, wld'
0'
H112'
0'
H18'
H112'
0'
H112'
0'
H112'
T4'
T4, wld'
T6, <NPD 1'
T6, =>NPD 1'

Plant Design System (PDS) Piping Component Data

607

Codelists
2186
2188
2190
2192
2194
2196
2198
2200
2202
2220
2222
2224
2226
2228
2230
2232
2234
2236
2238
2240
2242
2244
2246
2248
2250
2252
2254

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'B345-6061 temper T6, wld'


'B345-6063 temper T4'
'B345-6063 temper T4, wld'
'B345-6063 temper T5'
'B345-6063 temper T5, wld'
'B345-6063 temper T6'
'B345-6063 temper T6, wld'
'B345-Alclad 3002 temper 0'
'B345-Alclad 3002 temper H112'
'B361-WP1060 temper 0'
'B361-WP1060 temper H112'
'B361-WP1100 temper 0'
'B361-WP1100 temper H112'
'B361-WP3003 temper 0'
'B361-WP3003 temper H112'
'B361-WP5154 temper 0'
'B361-WP5154 temper H112'
'B361-WP6061 temper T4'
'B361-WP6061 temper T4, wld'
'B361-WP6061 temper T6'
'B361-WP6061 temper T6, wld'
'B361-WP6063 temper T4'
'B361-WP6063 temper T4, wld'
'B361-WP6063 temper T6'
'B361-WP6063 temper T6, wld'
'B361-AP Alclad 3003 temper 0'
'B361-AP Alclad 3003 temper H112'

Other Materials 2300-2999


2310 = 'B337-1'
2311 = 'B337-2'
2313 = 'B337-3'
2317 = 'B337-7'
2320 = 'C76-CLIII'
2325 = 'C443'
2350 = 'C700'
2400 = 'D1785-PVC1120'
2402 = 'D2467-PVC1120'
2440 = 'F439-CPVC4120'
2442 = 'F441-CPVC4120'

608

Plant Design System (PDS) Piping Component Data

Codelists
Gaskets 3000-3999]
3051 = 'G51'
[Flat, org fib, nitrile binder]
3052 = 'G52'
[Flat, org fib, nitrile binder, full face]
3076 = 'G76'
[Flat, graph]
3077 = 'G77'
[Flat, graph, full face]
3078 = 'G78'
[Flat, graph, 304 tang reinf]
3079 = 'G79'
[Flat, graph, 304 wire mesh reinf]
3101 = 'G101'
[Flat, asb]
3102 = 'G102'
[Flat, asb, full face]
3103 = 'G103'
[Flat, asb, wire mesh reinf]
3111 = 'G111'
[Flat, blue-asb]
3112 = 'G112'
[Flat, blue-asb, full face]
3154 = 'G154'
[Flat, Buna-N]
3171 = 'G171'
[Flat, Hypalon]
3175 = 'G175'
[Flat, Kel-F]
3189 = 'G189'
[Flat, neoprene]
3195 = 'G195'
[Flat, polyethylene]
3204 = 'G204'
[Flat, Teflon]
3210 = 'G210'
[Flat, Viton]
3231 = 'G231'
[Flat, soft-iron]
3234 = 'G234'
[Flat, 304]
3236 = 'G236'
[Flat, 321/347
3241 = 'G241'
[Corr, soft-iron]
3244 = 'G244'
[Corr, 304]
3246 = 'G246'
[Corr, 321/347
3251 = 'G251'
[Flat dbl jktd, PTFE-J, asb-F]
3256 = 'G256'
[Flat dbl jktd, Teflon-J, blue-asb-F]
3261 = 'G261'
[Flat dbl jktd, soft-iron-J, graph-F]
3262 = 'G262'
[Flat dbl jktd, soft-iron-J, asb-F]
3266 = 'G266'
[Flat dbl jktd, low-C-steel-J, graph-F]
3267 = 'G267'
[Flat dbl jktd, low-C-steel-J, asb-F]
3271 = 'G271'
[Flat dbl jktd, 304-J, graph-F]
3272 = 'G272'
[Flat dbl jktd, 304-J, asb-F]
3276 = 'G276'
[Flat dbl jktd, 321/347-J, graph-F]
3277 = 'G277'
[Flat dbl jktd, 321/347-J, asb-F]
3281 = 'G281'
[Flat dbl jktd, I600-J, graph-F]
3282 = 'G282'
[Flat dbl jktd, I600-J, asb-F]
3286 = 'G286'
[Flat dbl jktd, I800-J, graph-F
3306 = 'G306'
[Corr dbl jktd, soft-iron-J, graph-F]
3307 = 'G307'
[Corr dbl jktd, soft-iron-J, asb-F]
3311 = 'G311'
[Corr dbl jktd, low-C-steel-J, graph-F]
3312 = 'G312'
[Corr dbl jktd, low-C-steel-J, asb-F]
3316 = 'G316'
[Corr dbl jktd, 304-J, graph-F]
3317 = 'G317'
[Corr dbl jktd, 304-J, asb-F]
3321 = 'G321'
[Corr dbl jktd, 321/347-J, graph-F]
3322 = 'G322'
[Corr dbl jktd, 321/347-J, asb-F]
3326 = 'G326'
[Corr dbl jktd, I600-J, graph-F]
3327 = 'G327'
[Corr dbl jktd, I600-J, asb-F]
3331 = 'G331'
[Corr dbl jktd, I800-J, graph-F
3356 = 'G356'
[Inlaid corr, soft-iron-J, asb-chords]
3361 = 'G361'
[Inlaid corr, low-C-steel-J, asb-chords]
3366 = 'G366'
[Inlaid corr, 304-J, asb-chords

Plant Design System (PDS) Piping Component Data

609

Codelists
3403
3404
3408
3429
3435
3436
3441
3451
3452
3463
3466
3468
3473
3476
3477
3488
3491
3493
3498
3551
3552
3556
3563
3566
3568
3569
3573
3601
3602
3606
3608
3610
3613
3616
3618
3619
3623
3651
3653
3655
3657
3659
3661
3663
3665
3669

610

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'G403'
'G404'
'G408'
'G429'
'G435'
'G436'
'G441'
'G451'
'G452'
'G463'
'G466'
'G468'
'G473'
'G476'
'G477'
'G488'
'G491'
'G493'
'G498'
'G551'
'G552'
'G556'
'G563'
'G566'
'G568'
'G569'
'G573'
'G601'
'G602'
'G606'
'G608'
'G610'
'G613'
'G616'
'G618'
'G619'
'G623'
'G651'
'G653'
'G655'
'G657'
'G659'
'G661'
'G663'
'G665'
'G669'

[O ring, Buna-N]
[O ring, butyl]
[O ring, EDPM]
[O ring, nitrile]
[O ring, Saran]
[O ring, synthetic rubber]
[O ring, Viton
[BX ring, soft-iron, 90 BHN max]
[BX ring, lo-C, 120 BHN max]
[BX ring, 304, 140 BHN max]
[BX ring, 316, 140 BHN max]
[BX ring, 321, 140 BHN max]
[BX ring, I-X-750
[RX ring, soft-iron, 90 BHN max]
[RX ring, lo-C, 120 BHN max]
[RX ring, 304, 140 BHN max]
[RX ring, 316, 140 BHN max]
[RX ring, 321, 140 BHN max]
[RX ring, I-X-750
[Octag ring, soft-iron, 90 BHN max]
[Octag ring, lo-C, 120 BHN max]
[Octag ring, 5Cr-0.5Mo, 130 BHN max]
[Octag ring, 304, 140 BHN max]
[Octag ring, 316, 140 BHN max]
[Octag ring, 321, 140 BHN max]
[Octag ring, 347, 140 BHN max]
[Octag ring, I-X-750
[Oval ring, soft-iron, 90 BHN max]
[Oval ring, lo-C, 120 BHN max]
[Oval ring, 5Cr-0.5Mo, 130 BHN max]
[Oval ring, 9Cr-1Mo, 130 BHN max]
[Oval ring, 410, 170 BHN max]
[Oval ring, 304, 140 BHN max]
[Oval ring, 316, 140 BHN max]
[Oval ring, 321, 140 BHN max]
[Oval ring, 347, 140 BHN max]
[Oval ring, I-X-750
[Sprl-wnd, 304-W, mica/graph-F, CS-CR]
[Sprl-wnd, 304-W, graph-F, CS-CR]
[Sprl-wnd, 304-W, asb-F, CS-CR]
[Sprl-wnd, 304-W, blue-asb-F, CS-CR]
[Sprl-wnd, 304-W, Teflon-F, CS-CR]
[Sprl-wnd, 304-W, mica/graph-F, CS-CR, 304-IR]
[Sprl-wnd, 304-W, graph-F, CS-CR, 304-IR]
[Sprl-wnd, 304-W, asb-F, CS-CR, 304-IR]
[Sprl-wnd, 304-W, Teflon-F, CS-CR, 304-IR

Plant Design System (PDS) Piping Component Data

Codelists
3671
3673
3675
3677
3679
3681
3683
3685
3689
3691
3693
3695
3699
3701
3703
3705
3709
3711
3713
3715
3719
3721
3723
3725
3729
3731
3733
3735
3739
3741
3743
3745
3749
3751
3753
3755
3761
3763
3765
3771
3773
3775
3781
3783
3785

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'G671'
'G673'
'G675'
'G677'
'G679'
'G681'
'G683'
'G685'
'G689'
'G691'
'G693'
'G695'
'G699'
'G701'
'G703'
'G705'
'G709'
'G711'
'G713'
'G715'
'G719'
'G721'
'G723'
'G725'
'G729'
'G731'
'G733'
'G735'
'G739'
'G741'
'G743'
'G745'
'G749'
'G751'
'G753'
'G755'
'G761'
'G763'
'G765'
'G771'
'G773'
'G775'
'G781'
'G783'
'G785'

[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,
[Sprl-wnd,

316-W, mica/graph-F, CS-CR]


316-W, graph-F, CS-CR]
316-W, asb-F, CS-CR]
316-W, crodidolite asb-F, CS-CR]
316-W, Teflon-F, CS-CR]
316-W, mica/graph-F, CS-CR, 316-IR]
316-W, graph-F, CS-CR, 316-IR]
316-W, asb-F, CS-CR, 316-IR]
316-W, Teflon-F, CS-CR, 316-IR
316L-W, mica/graph-F, CS-CR]
316L-W, graph-F, CS-CR]
316L-W, asb-F, CS-CR]
316L-W, Teflon-F, CS-CR]
316L-W, mica/gra-F, CS-CR, 316L-IR]
316L-W, graph-F, CS-CR, 316L-IR]
316L-W, asb-F, CS-CR, 316L-IR]
316L-W, Teflon-F, CS-CR, 316L-IR
321-W, mica/graph-F, CS-CR]
321-W, graph-F, CS-CR]
321-W, asb-F, CS-CR]
321-W, Teflon-F, CS-CR]
321-W, mica/graph-F, CS-CR, 321-IR]
321-W, graph-F, CS-CR, 321-IR]
321-W, asb-F, CS-CR, 321-IR]
321-W, Teflon-F, CS-CR, 321-IR
347-W, mica/graph-F, CS-CR]
347-W, graph-F, CS-CR]
347-W, asb-F, CS-CR]
347-W, Teflon-F, CS-CR]
347-W, mica/graph-F, CS-CR, 347-IR]
347-W, graph-F, CS-CR, 347-IR]
347-W, asb-F, CS-CR, 347-IR]
347-W, Teflon-F, CS-CR, 347-IR
I600-W, mica/graph-F, CS-CR]
I600-W, graph-F, CS-CR]
I600-W, asb-F, CS-CR]
I600-W, mica/graph-F, I600-O&IR]
I600-W, graph-F, I600-O&IR]
I600-W, asb-F, I600-O&IR
I800-W, mica/graph-F, CS-CR]
I800-W, graph-F, CS-CR]
I800-W, asb-F, CS-CR]
I800-W, mica/graph-F, I800-O&IR]
I800-W, graph-F, I800-O&IR]
I800-W, asb-F, I800-O&IR

Plant Design System (PDS) Piping Component Data

611

Codelists
Bolting 4000-4999]
4011 = 'B11'
[A193-B5, >=1.5" lub, w/A194-3]
4012 = 'B12'
[A193-B5, lub, w/A194-3]
4014 = 'B14'
[A193-B5, >=1.5" lub, w/A194-4]
4015 = 'B15'
[A193-B5, lub, w/A194-4]
4021 = 'B21'
[A193-B6, >=1.5" lub, w/A194-6]
4022 = 'B22'
[A193-B6, lub, w/A194-6]
4031 = 'B31'
[A193-B7, >=1.5" lub, w/A194-2H]
4032 = 'B32'
[A193-B7, lub, w/A194-2H]
4033 = 'B33'
[A193-B7 zinc coated w/A194-2H zinc coated]
4035 = 'B35'
[A193-B7 galv w/A194-2H galv]
4038 = 'B38'
[A193-B7M, >=1.5" lub, w/A194-2H]
4039 = 'B39'
[A193-B7M, lub, w/A194-2H]
4041 = 'B41'
[A193-B8 Cl.1, >=1.5" lub, w/A194-8]
4042 = 'B42'
[A193-B8 Cl.1, lub, w/A194-8]
4044 = 'B44'
[A193-B8C Cl.1, >=1.5" lub, w/A194-8C]
4045 = 'B45'
[A193-B8C Cl.1, lub, w/A194-8C]
4046 = 'B46'
[A193-B8 Cl.1, lub, w/A194-8]
4047 = 'B47'
[A193-B8M Cl.1, >=1.5" lub, w/A194-8M]
4048 = 'B48'
[A193-B8M Cl.1, lub, w/A194-8M
4050 = 'B50'
[A193-B8T Cl.1, >=1.5" lub, w/A194-8T]
4051 = 'B51'
[A193-B8T Cl.1, lub, w/A194-8T]
4061 = 'B61'
[A193-B16, >=1.5" lub, w/A194-3]
4062 = 'B62'
[A193-B16, lub, w/A194-3]
4064 = 'B64'
[A193-B16, >=1.5" lub, w/A194-4]
4065 = 'B65'
[A193-B16, lub, w/A194-4]
4066 = 'B66'
[A193-B16, >=1.5" lub, w/A194-7]
4067 = 'B67'
[A193-B16, lub, w/A194-7]
4068 = 'B68'
[A193-B16, >=1.5" lub, w/A194-8M]
4069 = 'B69'
[A193-B16, lub, w/A194-8M]
4071 = 'B71'
[A307-B w/A563-A]
4074 = 'B74'
[A320-L7, >=1.5" lub, w/A194-4]
4075 = 'B75'
[A320-L7, lub, w/A194-4]
4076 = 'B76'
[A320-B8, >=1.5" lub, w/A194-8]
4077 = 'B77'
[A320-B8, lub, w/A194-8]
4078 = 'B78'
[A320-B8, >=1.5" lub, w/A194-B8]
4079 = 'B79'
[A320-B8, lub, w/A194-B8]
4080 = 'B80'
[A320-B8T Cl.1 >=1.5" lub, w/A194-B8]
4081 = 'B81'
[A320-B8T Cl.1 lub, w/A194-B8]
4082 = 'B82'
[A325 w/A325]
4084 = 'B84'
[A453-660, >=1.5" lub, w/A453-660]
4085 = 'B85'
[A453-660, lub, w/A453-660
4500 = 'Undefined'
Materials for British Standards - Ranges used 6000-7999

612

Plant Design System (PDS) Piping Component Data

Codelists
carbon steel pipes and tubes BS3601
6000 = 'BS3601:BW320'
6001 = 'BS3601:ERW320'
6002 = 'BS3601:ERW360'
6003 = 'BS3601:ERW430'
6004 = 'BS3601:S360'
6005 = 'BS3601:S430'
6006 = 'BS3601:SAW430'
steel pipes
6010 =
6011 =
6012 =
6013 =
6014 =
6015 =
6016 =
6017 =
6018 =
6019 =
6020 =
6021 =
6022 =
6023 =
6024 =
6025 =
6026 =
6027 =
6028 =
6029 =

and tubes BS3602 part 1 1987


'BS3602:PART 1:HFS360:Cat 1'
'BS3602:PART 1:HFS360:Cat 2'
'BS3602:PART 1:HFS430:Cat 1'
'BS3602:PART 1:HFS430:Cat 2'
'BS3602:PART 1:HFS500Nb:Cat 1'
'BS3602:PART 1:HFS500Nb:Cat 2'
'BS3602:PART 1:CFS360:Cat 1'
'BS3602:PART 1:CFS360:Cat 2'
'BS3602:PART 1:CFS430:Cat 1'
'BS3602:PART 1:CFS430:Cat 2'
'BS3602:PART 1:CFS500Nb:Cat 1'
'BS3602:PART 1:CFS500Nb:Cat 2'
'BS3602:PART 1:ERW360:Cat 1'
'BS3602:PART 1:ERW360:Cat 2'
'BS3602:PART 1:ERW430:Cat 1'
'BS3602:PART 1:ERW430:Cat 2'
'BS3602:PART 1:CEW360:Cat 1'
'BS3602:PART 1:CEW360:Cat 2'
'BS3602:PART 1:CEW430:Cat 1'
'BS3602:PART 1:CEW430:Cat 2'

steel pipes
6030 =
6031 =
6032 =
6033 =

and tubes elevated temp prop BS3602 part 2


'BS3602:PART 2:SAW410:cat 1'
'BS3602:PART 2:SAW410:cat 2'
'BS3602:PART 2:SAW460:cat 1'
'BS3602:PART 2:SAW460:cat 2'

steel pipes
6040 =
6041 =
6042 =
6043 =
6044 =
6045 =
6046 =
6047 =
6048 =
6049 =
6050 =
6051 =
6052 =
6053 =
6054 =
6055 =

and tubes low temp prop BS3603 1977


'BS3603 HFS410 LT 50 Cat 1'
'BS3603 HFS410 LT 50 Cat 2'
'BS3603 CFS410 LT 50 Cat 1'
'BS3603 CFS410 LT 50 Cat 2'
'BS3603 ERW410 LT 50 Cat 1'
'BS3603 ERW410 LT 50 Cat 2'
'BS3603 CEW410 LT 50 Cat 1'
'BS3603 CEW410 LT 50 Cat 2'
'BS3603 HFS503 LT 100 Cat 1'
'BS3603 HFS503 LT 100 Cat 2'
'BS3603 CFS503 LT 100 Cat 1'
'BS3603 CFS503 LT 100 Cat 2'
'BS3603 HFS509 LT 196 Cat 1'
'BS3603 HFS509 LT 196 Cat 2'
'BS3603 CFS509 LT 196 Cat 1'
'BS3603 CFS509 LT 196 Cat 2'

Plant Design System (PDS) Piping Component Data

613

Codelists
steel pipes
6060 =
6061 =
6062 =
6063 =
6064 =
6065 =
6066 =
6067 =
6068 =
6069 =
6070 =
6071 =
6072 =
6073 =
6074 =
6075 =
6076 =
6077 =
6078 =
6079 =
6080 =
6081 =
6082 =
6083 =
6084 =
6085 =
6086 =
6087 =
6088 =
6089 =
6090 =
6091 =
6092 =
6093 =
6094 =
6095 =
6096 =
6097 =
6098 =
6099 =
6100 =
6101 =
6102 =
6103 =
6104 =
6105 =
6106 =
6107 =

614

and tubes elevated


'BS3604:HFS620-460
'BS3604:CFS620-460
'BS3604:ERW620-460
'BS3604:CEW620-460
'BS3604:HFS620-460
'BS3604:CFS620-460
'BS3604:ERW620-460
'BS3604:CEW620-460
'BS3604:HFS620-440
'BS3604:CFS620-440
'BS3604:ERW620-440
'BS3604:CEW620-440
'BS3604:HFS620-440
'BS3604:CFS620-440
'BS3604:ERW620-440
'BS3604:CEW620-440
'BS3604:HFS621 Cat
'BS3604:CFS621 Cat
'BS3604:ERW621 Cat
'BS3604:CEW621 Cat
'BS3604:HFS621 Cat
'BS3604:CFS621 Cat
'BS3604:ERW621 Cat
'BS3604:CEW621 Cat
'BS3604:HFS660 Cat
'BS3604:CFS660 Cat
'BS3604:HFS660 Cat
'BS3604:CFS660 Cat
'BS3604:HFS622 Cat
'BS3604:CFS622 Cat
'BS3604:HFS622 Cat
'BS3604:CFS622 Cat
'BS3604:HFS625 Cat
'BS3604:CFS625 Cat
'BS3604:HFS625 Cat
'BS3604:CFS625 Cat
'BS3604:HFS629-470
'BS3604:CFS629-470
'BS3604:HFS629-470
'BS3604:CFS629-470
'BS3604:HFS629-590
'BS3604:CFS629-590
'BS3604:HFS629-590
'BS3604:CFS629-590
'BS3604:HFS762 Cat
'BS3604:CFS762 Cat
'BS3604:HFS762 Cat
'BS3604:CFS762 Cat

temp prop BS3604


Cat 1'
Cat 1'
Cat 1'
Cat 1'
Cat 2'
Cat 2'
Cat 2'
Cat 2'
Cat 1'
Cat 1'
Cat 1'
Cat 1'
Cat 2'
Cat 2'
Cat 2'
Cat 2'
1'
1'
1'
1'
2'
2'
2'
2'
1'
1'
2'
2'
1'
1'
2'
2'
1'
1'
2'
2'
Cat 1'
Cat 1'
Cat 2'
Cat 2'
Cat 1'
Cat 1'
Cat 2'
Cat 2'
1'
1'
2'
2'

Plant Design System (PDS) Piping Component Data

Codelists
SS pipes and tubes for pressure purposes BS3605:1973
6110 = 'BS3605 304S14'
6111 = 'BS3605 304S18'
6112 = 'BS3605 304S59'
6113 = 'BS3605 304S22'
6114 = 'BS3605 304S25'
6115 = 'BS3605 316S14'
6116 = 'BS3605 316S18'
6117 = 'BS3605 316S59'
6118 = 'BS3605 316S22'
6119 = 'BS3605 316S26'
6120 = 'BS3605 321S18'
6121 = 'BS3605 321S59(1010)'
6122 = 'BS3605 321S59(1105)'
6123 = 'BS3605 321S22'
6124 = 'BS3605 347S18'
6125 = 'BS3605 347S59'
6126 = 'BS3605 347S17'

Plant Design System (PDS) Piping Component Data

615

Codelists
plates BS1501 part 1 1980
6200 = 'BS1501-141 360A'
6201 = 'BS1501-151 360A'
6202 = 'BS1501-151 400A'
6203 = 'BS1501-151 430A'
6204 = 'BS1501-151 360B'
6205 = 'BS1501-151 400B'
6206 = 'BS1501-151 430B'
6207 = 'BS1501-154 360A'
6208 = 'BS1501-154 400A'
6209 = 'BS1501-154 430A'
6210 = 'BS1501-161 360A'
6211 = 'BS1501-161 400A'
6212 = 'BS1501-161 430A'
6213 = 'BS1501-161 360B'
6214 = 'BS1501-161 400B'
6215 = 'BS1501-161 430B'
6216 = 'BS1501-164 360A RT'
6217 = 'BS1501-164 360A LT0'
6218 = 'BS1501-164 360A LT20'
6219 = 'BS1501-164 360B RT'
6220 = 'BS1501-164 360B LT0'
6221 = 'BS1501-164 360B LT20'
6222 = 'BS1501-164 400A RT'
6223 = 'BS1501-164 400A LT0'
6224 = 'BS1501-164 400A LT20'
6225 = 'BS1501-164 400B RT'
6226 = 'BS1501-164 400B LT0'
6227 = 'BS1501-164 400B LT20'
6228 = 'BS1501-223 460A RT'
6229 = 'BS1501-223 460A LT0'
6230 = 'BS1501-223 460A LT15'
6231 = 'BS1501-223 460A LT30'
6232 = 'BS1501-223 460B RT'
6233 = 'BS1501-223 460B LT0'
6234 = 'BS1501-223 460B LT15'
6235 = 'BS1501-223 460B LT30'
6236 = 'BS1501-223 490A RT'
6237 = 'BS1501-223 490A LT0'
6238 = 'BS1501-223 490A LT15'
6239 = 'BS1501-223 490A LT30'
6240 = 'BS1501-223 490B RT'
6241 = 'BS1501-223 490B LT0'
6242 = 'BS1501-223 490B LT15'
6243 = 'BS1501-223 490B LT30'
6244 = 'BS1501-224 400A RT'
6245 = 'BS1501-224 400A LT0'
6246 = 'BS1501-224 400A LT20'
6247 = 'BS1501-224 400A LT30'
6248 = 'BS1501-224 400A LT40'
6249 = 'BS1501-224 400A LT50'
6250 = 'BS1501-224 400B RT'
6251 = 'BS1501-224 400B LT0'
6252 = 'BS1501-224 400B LT20'

616

Plant Design System (PDS) Piping Component Data

Codelists
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-224
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225
'BS1501-225

400B
400B
400B
430A
430A
430A
430A
430A
430A
430B
430B
430B
430B
430B
430B
460A
460A
460A
460A
460A
460A
460B
460B
460B
460B
460B
460B
490A
490A
490A
490A
490A
490A
490B
490B
490B
490B
490B
490B
460A
460A
460A
460A
460B
460B
460B
460B
490A
490A
490A
490B
490B
490B

LT30'
LT40'
LT50'
RT'
LT0'
LT20'
LT30'
LT40'
LT50'
RT'
LT0'
LT20'
LT30'
LT40'
LT50'
RT'
LT0'
LT20'
LT30'
LT40'
LT50'
RT'
LT0'
LT20'
LT30'
LT40'
LT50'
RT'
LT0'
LT20'
LT30'
LT40'
LT50'
RT'
LT0'
LT20'
LT30'
LT40'
LT50'
LT20'
LT30'
LT50'
LT60'
LT20'
LT30'
LT50'
LT60'
LT20'
LT30'
LT50'
LT20'
LT30'
LT50'

Plant Design System (PDS) Piping Component Data

617

Codelists
steel plates BS1501 part 2 1988
6310 = 'BS1501-243'
6311 = 'BS1501-271'
6312 = 'BS1501-281'
6313 = 'BS1501-620'
6314 = 'BS1501-621'
6315 = 'BS1501-622-515'
6316 = 'BS1501-622-690'
6317 = 'BS1501-660'
6318 = 'BS1501-503'
6319 = 'BS1501-510'
6320 = 'BS1501-828'

618

Plant Design System (PDS) Piping Component Data

Codelists
steel plates BS1501 part 3 1973
6321 = 'BS1501-403S17A'
6322 = 'BS1501-405S17A'
6323 = 'BS1501-304S12A'
6324 = 'BS1501-304S15A'
6325 = 'BS1501-304S49A'
6326 = 'BS1501-321S12A'
6327 = 'BS1501-321S49A'
6328 = 'BS1501-347S17A'
6329 = 'BS1501-347S49A'
6330 = 'BS1501-316S12A'
6331 = 'BS1501-316S16A'
6332 = 'BS1501-316S37A'
6333 = 'BS1501-316S49A'
6334 = 'BS1501-320S17A'
6335 = 'BS1501-310S24A'
6336 = 'BS1501-NA15A'
6337 = 'BS1501-NA16A'
6338 = 'BS1501-460S52A'
6339 = 'BS1501-304S62A'
6340 = 'BS1501-304S65A'
6341 = 'BS1501-304S87A'
6342 = 'BS1501-347S67A'
6343 = 'BS1501-316S62A'
6344 = 'BS1501-316S66A'
6345 = 'BS1501-316S82A'
6351 = 'BS1501-403S17B'
6352 = 'BS1501-405S17B'
6353 = 'BS1501-304S12B'
6354 = 'BS1501-304S15B'
6355 = 'BS1501-304S49B'
6356 = 'BS1501-351S12B'
6357 = 'BS1501-351S49B'
6358 = 'BS1501-347S17B'
6359 = 'BS1501-347S49B'
6360 = 'BS1501-316S12B'
6361 = 'BS1501-316S16B'
6362 = 'BS1501-316S37B'
6363 = 'BS1501-316S49B'
6364 = 'BS1501-320S17B'
6365 = 'BS1501-310S24B'
6366 = 'BS1501-NA15B'
6367 = 'BS1501-NA16B'
6368 = 'BS1501-460S52B'
6369 = 'BS1501-304S62B'
6370 = 'BS1501-304S65B'
6371 = 'BS1501-304S87B'
6372 = 'BS1501-377S67B'
6373 = 'BS1501-316S62B'
6374 = 'BS1501-316S66B'
6375 = 'BS1501-316S82B'
6376 = 'BS1501-460S52A LT70'

Plant Design System (PDS) Piping Component Data

619

Codelists
steel forgings to BS1503 1980
6380 = 'BS1503 164-490'
6381 = 'BS1503 221-410'
6382 = 'BS1503 221-430'
6383 = 'BS1503 221-460'
6384 = 'BS1503 221-490'
6385 = 'BS1503 221-510'
6386 = 'BS1503 221-530'
6387 = 'BS1503 221-550'
6388 = 'BS1503 223-410'
6389 = 'BS1503 223-430'
6390 = 'BS1503 223-460'
6391 = 'BS1503 223-490'
6392 = 'BS1503 223-510'
6393 = 'BS1503 224-410'
6394 = 'BS1503 224-430'
6395 = 'BS1503 224-460'
6396 = 'BS1503 224-490'
6397 = 'BS1503 224-510'
6398 = 'BS1503 245-420'
6399 = 'BS1503 620-440'
6400 = 'BS1503 620-540'
6401 = 'BS1503 621-460'
6402 = 'BS1503 660-460'
6403 = 'BS1503 271-560'
6404 = 'BS1503 622-490'
6405 = 'BS1503 622-560'
6406 = 'BS1503 622-650'
6407 = 'BS1503 625-520'
6408 = 'BS1503 625-590'
6409 = 'BS1503 503-490'
6410 = 'BS1503 509-690'
6411 = 'BS1503 410S21'
6412 = 'BS1503 420S29'
6413 = 'BS1503 403S17'
6414 = 'BS1503 405S17'
6415 = 'BS1503 304S11'
6416 = 'BS1503 304S31'
6417 = 'BS1503 304S51'
6418 = 'BS1503 347S31'
6419 = 'BS1503 347S51'
6420 = 'BS1503 321S31'
6421 = 'BS1503 321S51-490'
6422 = 'BS1503 321S51-510'
6423 = 'BS1503 316S11'
6424 = 'BS1503 316S13'
6425 = 'BS1503 316S31'
6426 = 'BS1503 316S33'
6427 = 'BS1503 316S51'
6428 = 'BS1503 320S33'
6429 = 'BS1503 310S31'

620

Plant Design System (PDS) Piping Component Data

Codelists
6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446
6447
6448
6449
6450
6451
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503

164-490E'
221-430E'
221-460E'
221-490E'
221-510E'
221-530E'
221-550E'
223-410E'
223-430E'
223-460E'
223-490E'
223-510E'
224-410E'
224-430E'
224-460E'
224-490E'
224-510E'
245-420E'
620-440E'
620-540E'
621-460E'
660-460E'
271-560E'
622-490E'
622-560E'
622-650E'
625-520E'
625-590E'
410S21E'
420S29E'
403S17E'
405S17E'
304S11E'
304S31E'
304S51E'
347S31E'
347S51E'
321S31E'
321S51-490E'
321S51-510E'
316S11E'
316S13E'
316S31E'
316S33E'
316S51E'

Plant Design System (PDS) Piping Component Data

621

Codelists
6475
6476
6477
6478
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498
6499
6500
6501
6502
6503
6504
6505
6506
6507
6508
6509
6510

622

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503
'BS1503

223-410-LT10'
223-410-LT20'
223-410-LT50'
223-430-LT10'
223-430-LT15'
223-430-LT40'
223-460-LT0'
223-460-LT10'
223-460-LT20'
223-490-LT0'
223-490-LT10'
223-510-LT0'
224-410-LT10'
224-410-LT20'
224-410-LT50'
224-430-LT10'
224-430-LT15'
224-430-LT40'
224-460-LT0'
224-460-LT10'
224-460-LT20'
224-490-LT0'
224-490-LT10'
224-510-LT0'
503-490-LT80'
509-690-LT196'
304S11-LT196'
304S31-LT196'
347S31-LT196'
321S31-LT196'
321S51-490'
321S51-510'
316S11-LT196'
316S13-LT196'
316S31-LT196'
316S33-LT196'

Plant Design System (PDS) Piping Component Data

Codelists
steel casting to BS1504 1976
6520 = 'BS1504-161 grade 430A'
6521 = 'BS1504-161 grade 480A'
6522 = 'BS1504-161 grade 540A'
6523 = 'BS1504-161 grade 430E'
6524 = 'BS1504-161 grade 480E'
6525 = 'BS1504-161 grade 430A-LT40'
6526 = 'BS1504-245A'
6527 = 'BS1504-245B'
6528 = 'BS1504-245A-LT50'
6529 = 'BS1504-503-LT60'
6530 = 'BS1504-621A'
6531 = 'BS1504-622A'
6532 = 'BS1504-622E'
6533 = 'BS1504-623A'
6534 = 'BS1504-625A'
6535 = 'BS1504-625E'
6536 = 'BS1504-629A'
6537 = 'BS1504-660A'
6538 = 'BS1504-420C29A'
6539 = 'BS1504-425C11A'
6540 = 'BS1504-304C15A'
6541 = 'BS1504-304C15A-LT196'
6542 = 'BS1504-304C12A'
6543 = 'BS1504-304C12A-LT196'
6544 = 'BS1504-347C17A'
6545 = 'BS1504-347C17A-LT196'
6546 = 'BS1504-315C16A'
6547 = 'BS1504-315C16A-LT196'
6548 = 'BS1504-316C12A'
6549 = 'BS1504-316C16A'
6550 = 'BS1504-316C71A'
6551 = 'BS1504-318C17A'
6552 = 'BS1504-316C16E'
6553 = 'BS1504-316C71E'
6554 = 'BS1504-316C12A-LT196'
6555 = 'BS1504-316C16A-LT196'
6556 = 'BS1504-316C71A-LT196'
6557 = 'BS1504-317C12A'
6558 = 'BS1504-317C16A'
6559 = 'BS1504-364C11A'
6560 = 'BS1504-332C11A'
6561 = 'BS1504-310C40A'
6562 = 'BS1504-330C11A'

Plant Design System (PDS) Piping Component Data

623

Codelists
steel bars and billets for bolting BS1506 1986
6570 = 'BS1506-162'
6571 = 'BS1506-253'
6572 = 'BS1506-253-LT100'
6573 = 'BS1506-509-650'
6574 = 'BS1506-509-650-LT196'
6575 = 'BS1506-509-690'
6576 = 'BS1506-509-690-LT196'
6577 = 'BS1506-630-790'
6578 = 'BS1506-630-790-LT100'
6579 = 'BS1506-630-790-LT75'
6580 = 'BS1506-630-860'
6581 = 'BS1506-630-860-LT100'
6582 = 'BS1506-630-690'
6583 = 'BS1506-630-690-LT100'
6584 = 'BS1506-631-850'
6585 = 'BS1506-670-860'
6586 = 'BS1506-671-850'
6587 = 'BS1506-681-820'
6588 = 'BS1506-410S21-690'
6589 = 'BS1506-410S21-720'
6590 = 'BS1506-410S21-760'
6591 = 'BS1506-410S21-750'
6592 = 'BS1506-410S21-770'
6593 = 'BS1506-416S29'
6594 = 'BS1506-286S31'
6595 = 'BS1506-286S31-LT196'
6596 = 'BS1506-304S31'
6597 = 'BS1506-304S31-LT196'
6598 = 'BS1506-304S51'
6599 = 'BS1506-304S61'
6600 = 'BS1506-304S61-LT196'
6601 = 'BS1506-304S71'
6602 = 'BS1506-304S71-LT196'
6603 = 'BS1506-303S22'
6604 = 'BS1506-316S31'
6605 = 'BS1506-316S31-LT196'
6606 = 'BS1506-316S33'
6607 = 'BS1506-316S33-LT196'
6608 = 'BS1506-316S51'
6609 = 'BS1506-316S53'
6610 = 'BS1506-316S61'
6611 = 'BS1506-316S61-LT196'
6612 = 'BS1506-316S63'
6613 = 'BS1506-316S63-LT196'
6614 = 'BS1506-316S65'
6615 = 'BS1506-316S65-LT196'
6616 = 'BS1506-316S67'
6617 = 'BS1506-316S67-LT196'
6618 = 'BS1506-321S31'
6619 = 'BS1506-321S31-LT196'
6620 = 'BS1506-321S51-490'
6621 = 'BS1506-321S51-520'
6622 = 'BS1506-347S31'

624

Plant Design System (PDS) Piping Component Data

Codelists
6623 = 'BS1506-347S31-LT196'
6624 = 'BS1506-347S51'
7999 = 'undefined'

CL148, Piping Materials Class Description (31999)


Codelist numbers 2-7999 are reserved for values that apply
to US practices. Codelist numbers 8000-31999 are reserved for
values that apply to practices in other countries.
1 = [Blank]
US Piping Material Class Descriptions, 2-7999
Irons,
2 =
3 =
6 =

F
[FAY1W8] [8F0002] 'Gravity Head, Gray CI'
[FDYLW8] [8F0003] 'Gravity Head, DI Cement Lined'
[FDYLU9] [9F0006] 'AWWA 150# MJ, DI Cement Lined'

Plant Design System (PDS) Piping Component Data

625

Codelists
Carbon
14 =
16 =
19 =
31 =
32 =
33 =
35 =
43 =
45 =
48 =
49 =
50 =
51 =
65 =
66 =
73 =
74 =
75 =
76 =
105 =
106 =
146 =
153 =
171 =
176 =
177 =
182 =
183 =
185 =
186 =
320 =
389 =
390 =
391 =
394 =
395 =
396 =
397 =
400 =
401 =
402 =
403 =
405 =
407 =
458 =
459 =
460 =
461 =
548 =
549 =
551 =
557 =
564 =

626

Steels, C
[CAA5UA] [AC0014]
[CAA5VA] [AC0016]
[CAALV1] [1C0019]
[CAC5C1] [1C0031]
[CAC5C2] [2C0032]
[CAC5C4] [4C0033]
[CAC5G1] [1C0035]
[CAC5Q1] [1C0043]
[CAC5R1] [1C0045]
[CAC5U1] [1C0048]
[CAC7C1] [1C0049]
[CAC7C2] [2C0050]
[CAC7C4] [4C0051]
[CAC8C1] [1C0065]
[CAC8C2] [2C0066]
[CAC9C1] [1C0073]
[CAC9C2] [2C0074]
[CAC9C4] [4C0075]
[CAC9C5] [5C0076]
[CAD7K1] [1C0105]
[CAD7K2] [2C0106]
[CAF5S1] [1C0146]
[CAF7J1] [1C0153]
[CAFYC1] [1C0171]
[CAH5C1] [1C0176]
[CAH5C2] [2C0177]
[CAH5G1] [1C0182]
[CAH5G2] [2C0183]
[CAH7C1] [1C0185]
[CAH7C2] [2C0186]
[CALYC2] [2C0320]
[CAU5P4] [4C0389]
[CAU5P5] [5C0390]
[CAU5P6] [6C0391]
[CAU5Q2] [2C0394]
[CAU5Q4] [4C0395]
[CAU5Q5] [5C0396]
[CAU5Q6] [6C0397]
[CAU5R2] [2C0400]
[CAU5R4] [4C0401]
[CAU5R5] [5C0402]
[CAU5R6] [6C0403]
[CAU5RF] [FC0405]
[CAU7C6] [6C0407]
[CAYYC1] [1C0458]
[CAYYC2] [2C0459]
[CDA1U1] [1C0460]
[CDA5U1] [1C0461]
[CJD7K1] [1C0548]
[CJD7K2] [2C0549]
[CJD7K5] [5C0551]
[CJD8K2] [2C0557]
[CJD9K1] [1C0564]

'CL125 FFFE, CS, Brnz Trim'


'CL125 FFFE, Brnz Trim'
'CL150 FFFE, CS Cement Lined'
'CL150 RFFE, CS, Trim 8'
'CL300 RFFE, CS, Trim 8'
'CL600 RFFE, CS, Trim 8'
'CL150 RFFE, CS, Trim 8'
'CL150 RFFE, CS, Trim 8, (ANSI-B31.1)'
'CL150 RFFE, CS, Trim 8'
'CL150 RFFE, CS, Trim 8'
'CL150 RFFE, CS, Trim 8'
'CL300 RFFE, CS, Trim 8'
'CL600 RFFE, CS, Trim 8'
'CL150 RFFE, CS, Trim 8'
'CL300 RFFE, CS, Trim 8'
'CL150 RFFE, CS, Trim 8'
'CL300 RFFE, CS, Trim 8'
'CL600 RFFE, CS, Trim 8'
'CL900 RFFE, CS, Trim 8'
'CL150 RFFE, CS, Trim 9'
'CL300 RFFE, CS, Trim 9'
'CL150 RFFE, CS, SS/TFE Trim'
'CL150 RFFE, CS, Trim 13'
'CL150 RFFE, CS, 316 Trim'
'CL150 RFFE-SF, CS, Trim 8'
'CL300 RFFE-SF, CS, Trim 8'
'CL150 RFFE-SF, CS, Trim 8'
'CL300 RFFE-SF, CS, Trim 8'
'CL150 RFFE-SF, CS, Trim 8'
'CL300 RFFE-SF, CS, Trim 8'
'CL300 RFFE-SF, CS, 316 Trim'
'CL600 BE/RFFE, CS, Trim 8, (ASME-I)'
'CL900 BE/RFFE, CS, Trim 5, (ASME-I)'
'CL1500 BE/RJFE, CS, Trim 5, (ASME-I)'
'CL300 BE/RFFE, CS, Trim 8, (ANSI-B31.1)'
'CL600 BE/RFFE, CS, Trim 8, (ANSI-B31.1)'
'CL900 BE/RFFE, CS, Trim 5, (ANSI-B31.1)'
'CL1500 BE/RJFE, CS, Trim 5, (ANSI-B31.1)'
'CL300 BE/RFFE, CS, Trim 8, (ANSI-B31.3)'
'CL600 BE/RFFE, CS, Trim 8, (ANSI-B31.3)'
'CL900 BE/RFFE, CS, Trim 5, (ANSI-B31.3)'
'CL1500 BE/RJFE, CS, Trim 5, (ANSI-B31.3)'
'CL800 BE/RFFE, CS, Trim 5, (ANSI-B31.3)'
'CL1500 BE/RJFE, CS, Trim 8'
'CL150 BE, CS'
'CL300 BE, CS'
'CL150 FFFE, Galv CS, Brnz Trim'
'CL150 FFFE, Galv CS, Brnz Trim'
'CL150 RFFE, Killed CS, Trim 12'
'CL300 RFFE, Killed CS, Trim 12'
'CL900 RFFE, Killed CS, Trim 12'
'CL300 RFFE, Killed CS, Trim 12'
'CL150 RFFE, Killed CS, Trim 12'

Plant Design System (PDS) Piping Component Data

Codelists
577
593
600
601
602
609
610
611
618
619
620
630
722
723
724
730
731
732
785
794
800
803
841
842

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[CJE7C2]
[CJE9C2]
[CJF5C1]
[CJF5C2]
[CJF5C4]
[CJF7C1]
[CJF7C2]
[CJF7C4]
[CJF9C1]
[CJF9C2]
[CJF9C4]
[CJH7C4]
[CJL7C2]
[CJL7C4]
[CJL7C5]
[CJL9C2]
[CJL9C4]
[CJL9C5]
[CJU7C6]
[CJV5C6]
[CJV7C6]
[CJV7K6]
[CPD5D1]
[CPD5D2]

[2C0577]
[2C0593]
[1C0600]
[2C0601]
[4C0602]
[1C0609]
[2C0610]
[4C0611]
[1C0618]
[2C0619]
[4C0620]
[4C0630]
[2C0722]
[4C0723]
[5C0724]
[2C0730]
[4C0731]
[5C0732]
[6C0785]
[6C0794]
[6C0800]
[6C0803]
[1C0841]
[2C0842]

'CL300 RFFE, Killed CS, NACE, Trim 9'


'CL300 RFFE, Killed CS, NACE, Trim 9'
'CL150 RFFE, Killed CS, NACE, Trim 12'
'CL300 RFFE, Killed CS, NACE, Trim 12'
'CL600 RFFE, Killed CS, NACE, Trim 12'
'CL150 RFFE, Killed CS, NACE, Trim 12'
'CL300 RFFE, Killed CS, NACE, Trim 12'
'CL600 RFFE, Killed CS, NACE, Trim 12'
'CL150 RFFE, Killed CS, NACE, Trim 12'
'CL300 RFFE, Killed CS, NACE, Trim 12'
'CL600 RFFE, Killed CS, NACE, Trim 12'
'CL600 RFFE-SF, Killed CS, Trim 8'
'CL300 RFFE-SF, Killed CS, NACE, Trim 12'
'CL600 RFFE-SF, Killed CS, NACE, Trim 12'
'CL900 RFFE-SF, Killed CS, NACE, Trim 12'
'CL300 RFFE-SF, Killed CS, NACE, Trim 12'
'CL600 RFFE-SF, Killed CS, NACE, Trim 12'
'CL900 RFFE-SF, Killed CS, NACE, Trim 12'
'CL1500 BE/RJFE, Killed CS, Trim 8'
'CL1500 BE/RJFE, Killed CS, Trim 8'
'CL1500 BE/RJFE, Killed CS, NACE, Trim 12'
'CL1500 BE/RJFE, Killed CS, Trim 12'
'CL150 RFFE, Low Temp CS, Trim 2'
'CL300 RFFE, Low Temp CS, Trim 2'

Plant Design System (PDS) Piping Component Data

627

Codelists
Low and Intermediate Alloy Steels, L
1669 = [LPFYG2] [2L1669] 'CL300 RFFE, 1.25Cr-0.5Mo, 316 Trim'
1670 = [LPTYG2] [2L1670] 'CL300 RFFE, 1.25Cr-0.5Mo, 316 Trim'
1671 = [LPH5B1] [1L1671] 'CL150 RFFE-SF, 1.25Cr-0.5Mo, Trim 8'
1672 = [LPH5B2] [2L1672] 'CL300 RFFE-SF, 1.25Cr-0.5Mo, Trim 8'
1673 = [LPH5B4] [4L1673] 'CL600 RFFE-SF, 1.25Cr-0.5Mo, Trim 8'
1677 = [LPH7B1] [1L1677] 'CL150 RFFE-SF, 1.25Cr-0.5Mo, Trim 8'
1678 = [LPH7B2] [2L1678] 'CL300 RFFE-SF, 1.25Cr-0.5Mo, Trim 8'
1679 = [LPH7B4] [4L1679] 'CL600 RFFE-SF, 1.25Cr-0.5Mo, Trim 8'
1691 = [LPH9B4] [4L1691] 'CL600 RFFE-SF, 1.25Cr-0.5Mo, Trim 8'
1864 = [LPU5B6] [6L1864] 'CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 8'
1868 = [LPU5P5] [5L1868] 'CL900 BE/RFFE, 1.25Cr-0.5Mo, Trim 5,
(ASME-I)'
1869 = [LPU5P6] [6L1869] 'CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 5,
(ASME-I)'
1874 = [LPU5Q5] [5L1874] 'CL900 BE/RFFE, 1.25Cr-0.5Mo, Trim 5,
(ANSI-B31.1)'
1875 = [LPU5Q6] [6L1875] 'CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 5,
(ANSI-B31.1)'
1882 = [LPU5R6] [6L1882] 'CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 5,
(ANSI-B31.3)'
1885 = [LPU7B6] [6L1885] 'CL1500 BE/RJFE, 1.25Cr-0.5Mo, Trim 8'
3013 = [LTC5B1] [1L3013] 'CL150 RFFE, 5Cr-0.5Mo, Trim 8'
3014 = [LTC5B2] [2L3014] 'CL300 RFFE, 5Cr-0.5Mo, Trim 8'
3027 = [LTC7B1] [1L3027] 'CL150 RFFE, 5Cr-0.5Mo, Trim 8'
3028 = [LTC7B2] [2L3028] 'CL300 RFFE, 5Cr-0.5Mo, Trim 8'
3029 = [LTC7B4] [4L3029] 'CL600 RFFE, 5Cr-0.5Mo, Trim 8'
3040 = [LTC8B1] [1L3040] 'CL150 RFFE, 5Cr-0.5Mo, Trim 8'
3041 = [LTC8B2] [2L3041] 'CL300 RFFE, 5Cr-0.5Mo, Trim 8'
3042 = [LTC8B4] [4L3042] 'CL600 RFFE, 5Cr-0.5Mo, Trim 8'
3048 = [LTC9B1] [1L3048] 'CL150 RFFE, 5Cr-0.5Mo, Trim 8'
3049 = [LTC9B2] [2L3049] 'CL300 RFFE, 5Cr-0.5Mo, Trim 8'
3193 = [LTH7B5] [5L3193] 'CL900 RFFE-SF, 5Cr-0.5Mo, Trim 8'
3203 = [LTH9B2] [2L3203] 'CL300 RFFE-SF, 5Cr-0.5Mo, NACE, Trim 8'
3204 = [LTH9B4] [4L3204] 'CL600 RFFE-SF, 5Cr-0.5Mo, NACE, Trim 8'
3390 = [LTU7B6] [6L3390] 'CL1500 BE/RJFE, 5Cr-0.5Mo, Trim 8'
3725 = [LVC7B1] [1L3725] 'CL150 RFFE, 9Cr-1Mo, Trim 8'
3726 = [LVC7B2] [2L3726] 'CL300 RFFE, 9Cr-1Mo, Trim 8'
3746 = [LVC9B1] [1L3746] 'CL150 RFFE, 9Cr-1Mo, Trim 8'
3747 = [LVC9B2] [2L3747] 'CL300 RFFE, 9Cr-1Mo, Trim 8'
3748 = [LVC9B4] [4L3748] 'CL600 RFFE, 9Cr-1Mo, Trim 8'
3749 = [LVC9B5] [5L3749] 'CL900 RFFE, 9Cr-1Mo, Trim 8'

628

Plant Design System (PDS) Piping Component Data

Codelists
Stainless Steels, S
3977 = [SAC3T1] [1S3977] 'CL150 RFFE, 304/CS Valves, Trim 8'
3978 = [SAC3T2] [2S3978] 'CL300 RFFE, 304/CS Valves, Trim 8'
3979 = [SAC3T4] [4S3979] 'CL600 RFFE, 304/CS Valves, Trim 8'
3980 = [SAC3T5] [5S3980] 'CL900 RFFE, 304/CS Valves, Trim 8'
3984 = [SAD3C1] [1S3984] 'CL150 RFFE, 304/316 Valves, Trim 12'
3985 = [SAD3C2] [2S3985] 'CL300 RFFE, 304/316 Valves, Trim 12'
3988 = [SAD3E1] [1S3988] 'CL150 RFFE, 304, Trim 2'
3989 = [SAD3E2] [2S3989] 'CL300 RFFE, 304, Trim 2'
3991 = [SAD3F1] [1S3991] 'CL150 RFFE, 304, Trim 2'
4104 = [SAFYG1] [1S4104] 'CL150 RFFE, 304, 316 Trim'
4218 = [SAM3T6] [6S4218] 'CL1500 RJFE, 304/CS Valves, Trim 8'
4396 = [SBD3C2] [2S4396] 'CL300 RFFE, 304L/316 Valves, Trim 12'
4488 = [SBF3U1] [1S4488] 'CL150 RFFE, 304/316 Valves, Trim 2'
5135 = [SED5C1] [1S5135] 'CL150 RFFE, 316, Trim 12'
5187 = [SEF3C1] [1S5187] 'CL150 RFFE, 316, Trim 12'
5188 = [SEF3C2] [2S5188] 'CL300 RFFE, 316, Trim 12'
5189 = [SEF3C4] [4S5189] 'CL600 RFFE, 316, Trim 12'
5197 = [SEF3G1] [1S5197] 'CL150 RFFE, 316, Trim 12'
6246 = [SHJ3B2] [2S6246] 'CL300 RFFE-SF, 321/347 Valves, 347HF Trim'
6247 = [SHJ3B4] [4S6247] 'CL600 RFFE-SF, 321/347 Valves, 347HF Trim'
6258 = [SHJ5B2] [2S6258] 'CL300 RFFE-SF, 321/347 Valves, 347HF Trim'
6449 = [SHV3B5] [5S6449] 'CL900 BE/RFFE-SF, 321/347 Valves, 347HF
Trim'
6450 = [SHV3B6] [6S6450] 'CL1500 BE/RJFE, 321/347 Valves, 347HF Trim'
6457 = [SHV5B6] [6S6457] 'CL1500 BE/RJFE, 321/347 Valves, 347HF Trim'
Copper Alloys, K
Nickel Alloys, N
7540 = [NGF5G1] [1N7540] 'CL150 RFFE, Inconel 600, Inconel Trim'
Aluminum Alloys, A
Other Materials, X
7687 = [XCY1W8] [8X7687] 'Gravity Head, Vitrified Clay'
7689 = [XEY1W8] [8X7689] 'Gravity Head, Reinforced Concrete'
7733 = [XTY1U9] [9X7733] 'SCH-80, SE, PVC'
European Piping Material Class Descriptions, 8000-9999
8000 = 'Carbon steel'
8001 = 'Stainless steel'
8002 = 'Forged steel'
8010 = 'Ferritic steel'
8011 = 'Austenitic steel'
8020 = 'Plastic'
8021 = 'Fiber glass'
8030 = 'Glass lined'
8031 = 'Cement lined'
8032 = 'Chloroprene (CR) lined'
9999 = 'Undefined'
The names of Piping Materials Classes are determined as follows:

Plant Design System (PDS) Piping Component Data

629

Codelists
o A list includes possible Piping Materials Classes. It consists of
six character names, which are established on the basis of the naming
convention ABCDEF. The meaning of each of the characters in this code
is defined below. Corresponding values are given in the lists
included in subsequent pages.
A.......materials group
B.......materials type
C.......detail features
D.......corrosion allowance or type of lining
E.......service description
F.......pressure rating
o The name of a Piping Materials Class is then determined from the
convention FAXXX, where:
F.......pressure rating
A.......material group
XXX.....sequence number from list in 2090-41-SN
MATERIALS GROUP AND TYPE: (1st and 2nd character)
Irons, F
A= Gray iron
D= Ductile iron
G= Ferritic ductile iron
J= Austenitic ductile iron
Z= Other 1
Carbon Steels, C
A= CS
D= CS, galvanized
G= CS, jacketed
J= CS, killed
M= CS, killed, jacketed
P= CS, low temp
X= Other 1
Y= Other 2
Z= Other 3

630

Plant Design System (PDS) Piping Component Data

Codelists
Low
A=
C=
D=
G=
J=
M=
N=
P=
Q=
R=
S=
T=
U=
V=
X=
Y=
Z=

and Intermediate Alloys, L


2Ni-1Cu
3.5Ni
5Ni
9Ni
C-0.5Mo
0.75Cr-0.5Mo
1Cr-0.5Mo
1.25Cr-0.5Mo
2Cr-0.5Mo
2.25Cr-1Mo
3Cr-1Mo
5Cr-0.5Mo
7Cr-0.5Mo
9Cr-1Mo
Other 1
Other 2
Other 3

Stainless Steels, S
A= 304
B= 304L
C= 304H
D= 310
E= 316
F= 316L
G= 316H
H= 321
J= 321H
K= 410S
L= CHP10
M= CHP20
N= CPF10MC
O= CPH8
P= CPK20
Q= UNS S31200
R= UNS S31250
S= UNS S31500
T= UNS S31803
U= UNS S32304
V= UNS S32550
W= Alloy 20
X= Other 1
Y= Other 2
Z= Other 3

Plant Design System (PDS) Piping Component Data

631

Codelists
Copper Alloys, K
A= Brass
F= Bronze
K= Copper
P= 90Cu-10Ni
R= 70Cu-30Ni
X= Other 1
Y= Other 2
Z= Other 3
Nickel Alloys, N
A= Low C Ni
D= Monel
E= K-Monel
F= R-Monel
G= Inconel 600
H= Inconel 601
J= Inconel 625
L= Incoloy 800
M= Incoloy 800H
N= Incoloy 801
P= Incoloy 802
Q= Incoloy 825
T= Hastelloy B
U= Hastelloy C
V= Hastelloy G
X= Other 1
Y= Other 2
Z= Other 3
Aluminum Alloys, A
C= 3002 aluminum
D= 3003 aluminum
E= 3004 aluminum
F= 5050 aluminum
G= 5052 aluminum
Q= 6061 aluminum
R= 6063 aluminum
S= Alclad
X= Other 1
Y= Other 2
Z= Other 3

632

Plant Design System (PDS) Piping Component Data

Codelists
Other Materials, X
A= Asbestos cement
B= Borosilicate glass
C= Clay, vitrified
D= Concrete, prestressed
E= Concrete, reinforced
F= CPVC
G= Epoxy/Glass fib
J= Furan/Carbon
K= Furan/Glass fib
L= Kynar
N= Nylon
P= Polyester/Glass fib
Q= Polyethylene, high dens
R= Polyethylene, low dens
S= Polypropylene
T= PVC
U= Teflon
V= Titanium
W= Zirconium
X= Other 1
Y= Other 2
Z= Other 3
MATERIALS CLASS DETAILS: (3rd character)
A=
B=
C=
D=
E=
F=
G=
H=
J=
K=
L=
M=
N=
0=
P=
Q=
R=
S=
T=
U=
V=
W=
X=
Y=
Z=

Std FF, std trim


Std FF, other
Std RF, std trim
Std RF, SS trim
Std RF, Monel trim
Std RF, other
Std RF, other
RFSF, std trim
RFSF, SS trim
RFSF, Monel trim
RFSF, other
RTJ, std trim
RTJ, SS trim
RTJ, Monel trim
RTJ, other
MJ, std trim
MJ, SS trim
MJ, Monel trim
MJ, other
BE, std trim
BE, SS trim
BE, Monel trim
BE, other
Other 1
Other 2

CA OR LINING TYPE: (4th character)

Plant Design System (PDS) Piping Component Data

633

Codelists
1=
2=
3=
4=
5=
6=
7=
8=
9=
A=
B=
C=
D=
E=
F=
G=
H=
J=
L=
M=
N=
O=
P=
Q=
R=
S=
T=
U=
V=
W=
X=
Y=
Z=

None
0.020"
0.030"
0.050"
0.063"
0.10"
0.125"
0.188"
0.250"
405 clad
410S clad
304 clad
304L clad
316 clad
316L clad
317 clad
317L clad
321 clad
Cement lined
Epoxy lined
Glass lined
Kynar lined
Polyester lined
Polypropylene lined
PTFE lined
Saran lined
Teflon lined
TK31 lined
R11 lined
R15 lined
R18 lined
Other 1
Other 2

SERVICE: (5th character)

634

Plant Design System (PDS) Piping Component Data

Codelists
A=
B=
C=
D=
E=
F=
G=
H=
J=
K=
L=
P=
Q=
R=
S=
T=
U=
V=
W=
X=
Y=
Z=

Process, hottest (-20 to 1500+/- degF)


Process, hotter (-20 to 1000+/- degF)
Process, hot (-20 to 800 degF)
Process, cold (-20 to -50 degF)
Process, colder (-20 to -150 degF)
Process, coldest (-20 to -425 degF)
Process, other
Category M
Acid
Caustic/Amine
LPG
Steam ASME-I
Steam B31.1
Steam B31.3
Fuel gas, fuel oil
Lube oil, seal oil
Category D
Firewater
Sewer
Instrument
Other 1
Other 2

RATING: (6th character)


1=
2=
3=
4=
5=
6=
7=
8=
9=
A=
F=
G=
H=
J=
K=
L=
M=
N=
R=
T=
V=

CL150
CL300
CL400
CL600
CL900
CL1500
CL2500
GRAVHD
OTHER
CL125
CL800
CL2000
CL3000
CL4500
CL5000
CL6000
CL9000
CL10000
CL15000
CL20000
CL30000

Plant Design System (PDS) Piping Component Data

635

Codelists

CL160, Responsibility (25)


1
2
3
4
5
6
7
8
9
10
15
16
25

=
=
=
=
=
=
=
=
=
=
=
=
=

[Blank]
'By Contractor'
'By Owner'
'By A'
'By B'
'By C'
'By D'
'By E'
'By Equip Vendor'
'By Vendor'
'By Piping'
'By Instruments'
'By Others'

CL180, Fabrication Category (99)


Some data displays require that only values to the left of
the "=" sign be shown; other reports require that only values to the
right of the "=" sign be displayed.
1
5
7
15
17
25
27
35
37
45
47
95
97

636

=
=
=
=
=
=
=
=
=
=
=
=
=

[Blank]
'CSSF, Contractor supplied, shop fabricated'
'CSFF, Contractor supplied, field fabricated'
'SSSF, Shop supplied, shop fabricated'
'SSFF, Shop supplied, field fabricated'
'FSSF, Field supplied, shop fabricated'
'FSFF, Field supplied, field fabricated'
'ASSF, A supplied, shop fabricated'
'ASFF, A supplied, field fabricated'
'BSSF, B supplied, shop fabricated'
'BSFF, B supplied, field fabricated'
'OSSF, Owner supplied, shop fabricated'
'OSFF, Owner supplied, field fabricated'

Plant Design System (PDS) Piping Component Data

Codelists

CL190, Coating Requirements (99)


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
40

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Blank]
'None'
'Galv'
'PS1.04'
'PS1.07'
'PS1.08'
'PS1.09'
'PS1.10'
'PS1.11'
'PS1.12'
'PS1.13'
'PS2.03'
'PS2.05'
'PS4.01'
'PS4.02'
'PS4.03'
'PS4.04'
'PS4.05'
'PS8.01'
'PS9.01'
'PS10.01'
'PS10.02'
'PS11.01'
'PS12.01'
'PS13.01'
'PS14.01'
'PS16.01'
'PS18.01'
'Varies'

CL200, Heat Tracing Requirements (10)


In editing this codelist set, do not change the meaning
of existing codelist values.
1
2
3
4

=
=
=
=

[Blank]
'NT'
[Not heat traced]
'HT'
[Heat traced]
'PHT' [Partially heat traced]

Plant Design System (PDS) Piping Component Data

637

Codelists

CL210, Heat Tracing Media (60)


Codelist numbers 3-39 have been reserved for heat tracing
media used for non-jacketed pipe heat tracing. Codelist numbers
40-60 have been reserved for heat tracing media used for jacketed pipe
heat tracing. It is important that this allocation be respected.
1 = [Blank]
2 = 'N'

[None]

For Non Jacketed Pipe Heat Tracing, 3-39


3 = 'E'
[Electric]
10 = 'FA'
[Heat transfer fluid A]
11 = 'FB'
[Heat transfer fluid B]
12 = 'FC'
[Heat transfer fluid C]
16 = 'I'
[Impedance]
17 = 'MI'
[Magnetic induction]
18 = 'SKE'
[Skin effect]
20 = 'SH'
[Steam high pressure, CL900]
21 = 'SL'
[Steam low pressure, CL150]
22 = 'SM'
[Steam medium pressure, CL600]
23 = 'SN'
[Steam normal pressure, CL300]
24 = 'SS'
[Steam superheated]
For Jacketed Pipe Heat Tracing, 40-60
40 = 'FAJ'
[Heat transfer fluid A]
41 = 'FBJ'
[Heat transfer fluid B]
42 = 'FCJ'
[Heat transfer fluid C]
50 = 'SHJ'
[Steam high pressure, CL900]
51 = 'SLJ'
[Steam low pressure, CL150]
52 = 'SMJ'
[Steam medium pressure, CL600]
53 = 'SNJ'
[Steam normal pressure, CL300]
54 = 'SSJ'
[Steam superheated]

638

Plant Design System (PDS) Piping Component Data

Codelists

CL220, Insulation Purpose (40)


1
2
3
4
5
11
14
15
16
17
18
20
21
22
30
32
34
40

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Blank]
'N'
'P'
'H'
'HS'
'HF'
'AS'
'C'
'CV'
'CS'
'CH'
'CF'
'S'
'SV'
'R11'
'R15'
'R18'
'Varies'

[Not insulated]
[Personnel protection insulated]
[Hot insulated]
[Hot insulated with sound attenuation]
[Hot insulated with fire protection]
[Anti-sweat insulated]
[Cold insulated]
[Cold insulated vacuum type]
[Cold insulated with sound attenuation]
[Cold and hot insulated]
[Cold insulated with fire protection]
[Sound attenuation insulated]
[Sound attenuation insulation with vapor barrier]
[Refractory lined, insulation]
[Refractory lined, insulation/erosion]
[Refractory lined, erosion]

CL230, Cleaning Requirements (99)


1
2
3
4
5
6
7
15

=
=
=
=
=
=
=
=

[Blank]
'None'
'CC1'
'CC2'
'CC3'
'CC4'
'CC5'
'Varies'

CL330, CP Type/Termination/Preparation (999)


Use 2-199 for bolted types; 300-399 for male types and
400-599 for female types. Refer to Reference Data Manager
(PD_DATA) Reference Guide for additional data.
1 = [Blank]
2 = 'FE'
Use 11-15 for ends without
integral gaskets.
10 = 'FFTP
(11-19)'
11 = 'FFFE'
16 = 'FFFEWG'

[Flanged end]
integral gaskets; 16-19 for ends with
[Flat-face flanged termination type]
[Flat-face flanged end]
[Flat-face flanged end with integral gasket]

Plant Design System (PDS) Piping Component Data

639

Codelists
Use 21-25 for ends without integral gaskets; 26-29 for ends with
integral gaskets.
20 = 'RFTP
(21-29)' [Raised-face flanged termination type]
21 = 'RFFE'
[Raised-face flanged end]
26 = 'RFFEWG'
[Raised-face flanged end with integral gasket]
Use 31-35 for ends without integral gaskets; 36-39 for ends with
integral gaskets.
30 = 'RJFTP
(31-39)' [RTJ-face flanged termination type]
31 = 'RJFE'
[RTJ-face flanged end]
Use 41-45 for ends without
integral gaskets.
40 = 'TMFTP
(41-49)'
41 = 'STFE'
42 = 'LTFE'
43 = 'SMFE'
44 = 'LMFE'

integral gaskets; 46-49 for ends with

Use 51-55 for ends without


integral gaskets.
50 = 'GFFTP
(51-59)'
51 = 'SGFE'
52 = 'LGFE'
53 = 'SFFE'
54 = 'LFFE'

integral gaskets; 56-59 for ends with

[Tongue/male-face flanged termination type]


[Small-tongue-face flanged end]
[Large-tongue-face flanged end]
[Small-male-face flanged end]
[Large-male-face flanged end]

[Groove/female-face flanged
[Small-groove-face flanged
[Large-groove-face flanged
[Small-female-face flanged
[Large-female-face flanged

termination type]
end]
end]
end]
end]

Use 61-65 for lap-flanged ends without integral gaskets; 66-69 for
lap-flanged ends with integral gaskets.
60 = 'FFLFTP
(61-69)' [Flat-face lap-flanged termination type]
61 = 'FFLFE
[Flat-face lap-flanged end]
Use 71-75 for lap-flanged ends without integral gaskets; 76-79 for
lap-flanged ends with integral gaskets.
70 = 'RFLFTP
(71-79)' [Raised-face lap-flanged termination type]
71 = 'RFLFE'
[Raised-face lap-flanged end]
Use 81-85 for lap-flanged ends without integral gaskets; 86-89 for
lap-flanged ends with integral gaskets.
80 = 'RJFLFTP
(81-89)' [RTJ-face lap-flanged termination type]
81 = 'RJLFE'
[RTJ-face lap-flanged end]
Use 91-95 for lap-flanged ends without integral gaskets; 96-99 for
lap-flanged ends with integral gaskets.
90 = 'TMFLFTP
(91-99)' [Tongue/male-face lap-flanged termination
type]
91 = 'STLFE'
[Small-tongue-face lap-flanged end]
92 = 'LTLFE'
[Large-tongue-face lap-flanged end]
93 = 'SMLFE'
[Small-male-face lap-flanged end]
94 = 'LMLFE'
[Large-male-face lap-flanged end]

640

Plant Design System (PDS) Piping Component Data

Codelists
Use 101-105 for lap-flanged ends without integral gaskets; 106-109
for lap-flanged ends with integral gaskets.
100 = 'GFFLFTP
(101-109)'[Groove/female-face lap-flanged termination
type]
101 = 'SGLFE'
[Small-groove-face lap-flanged end]
102 = 'LGLFE'
[Large-groove-face lap-flanged end]
103 = 'SFLFE'
[Small-female-face lap-flanged end]
104 = 'LFLFE'
[Large-female-face lap-flanged end]
Use 111-115 for ends without integral
with integral gaskets.
110 = 'FFTBTP
(111-119)'[Flat-face
111 = 'FFTBE'
[Flat-face
116 = 'FFTBEWG'
[Flat-face
gasket]

gaskets; 116-119 for ends


thru-bolted termination type]
thru-bolted end]
thru-bolted end with integral

Use 121-125 for ends without integral gaskets; 126-129 for ends
with integral gaskets.
120 = 'RFTBTP
(121-129)'[Raised-face thru-bolted termination type]
121 = 'RFTBE'
[Raised-face thru-bolted end]
126 = 'RFTBEWG'
[Raised-face thru-bolted end with integral
gasket]
Use 131-135 for ends without integral gaskets; 136-139 for ends
with integral gaskets.
130 = 'RJTBTP
(131-139)'[RTJ-face thru-bolted termination type]
131 = 'RJTBE'
[RTJ-face thru-bolted end]
Use 141-145 for ends without integral gaskets; 146-149 for ends
with integral gaskets.
140 = 'MRJTBTP
(141-149)'[Male RTJ-face thru-bolted termination type]
146 = 'MRJTBEWG'
[Male RTJ-face thru-bolted end with integral
gasket]
Use 151-155 for ends without integral
with integral gaskets.
150 = 'FFTBCSTP (151-159)'[Flat-face
termination type]
151 = 'FFTBCSE'
[Flat-face
156 = 'FFTBCSEWG'
[Flat-face
with integral gasket]

gaskets; 156-159 for ends


thru-bolted-with-cap-screws
thru-bolted-with-cap-screws end]
thru-bolted-with-cap-screws end

Use 161-165 for ends without integral gaskets; 166-169 for ends
with integral gaskets.
160 = 'RFTBCSTP (161-169)'[Raised-face thru-bolted-with-cap-screws
termination type]
161 = 'RFTBCSE'
[Raised-face thru-bolted-with-cap-screws end]
166 = 'RFTBCSEWG'
[Raised-face thru-bolted-with-cap-screws end
with integral gasket]

Plant Design System (PDS) Piping Component Data

641

Codelists
Use 171-175 for ends without integral gaskets; 176-179 for ends
with integral gaskets.
170 = 'RJTBCSTP (171-179)'[RTJ-face thru-bolted-with-cap-screws
termination type]
171 = 'RJTBCSE'
[RTJ-face thru-bolted-with-cap-screws end]
Use 181-185 for ends without integral gaskets; 186-189 for ends
with integral gaskets.
180 = 'FFFTBTP
(181-189)'[Flat-full-face thru-bolted termination type]
181 = 'FFFTBE'
[Flat-full-face thru-bolted end]
186 = 'FFFTBEWG'
[Flat-full-face thru-bolted end with integral
gasket]
190 = 'MJTP
(190-199)'[Mechanical joint termination type]
191 = 'MJE'
[Mechanical joint end]
300 = 'MTP
(301-399)'[Male termination type]
Use 301-309 for welded ends only
301 = 'BE'
[Beveled end]
302 = 'OLET'
[Olet beveled end]

642

Use
311
321
331
341
351
355
361
371
381

311-319 for welded ends only


= 'TBE'
[Tapered and beveled end]
= 'MFE'
[Male flared end]
= 'MTE'
[Male threaded end]
= 'MGE'
[Male grooved end]
= 'MQCE'
[Male quick connect end]
= 'MCE'
[Male clamp end]
= 'MFRE'
[Male ferrule end]
= 'MHE'
[Male hose end]
= 'SPE'
[Spigot end]

Use
391
393
395
400
401

391-399 for welded ends only


= 'PE
(391-399)'[Plain end]
= '3"FFPE'
[Plain end, 3" field fit]
= '6"FFPE'
[Plain end, 6" field fit]
= 'STP
(401-409)'[Socket termination type]
= 'SE'
[Socket end]

Use
420
421
440
441
460
461
470
471
480
481
500
501
520
521

421-429 for welded ends only


= 'SWTP
(421-429)'[Socketwelded termination type]
= 'SWE'
[Socketwelded end]
= 'FTTP
(441-449)'[Female threaded termination type]
= 'FTE'
[Female threaded end]
= 'FGTP
(461-469)'[Female grooved termination type]
= 'FGE'
[Female grooved end]
= 'FCTP
(471-479)'[Female clamp termination type]
= 'FCE'
[Female clamp end]
= 'FQCTP
(481-489)'[Female quick connect termination type]
= 'FQCE'
[Female quick connect end]
= 'FFRTP
(501-509)'[Female ferrule termination type]
= 'FFRE'
[Female ferrule end]
= 'FHTP
(521-529)'[Female hose termination type]
= 'FHE'
[Female hose end]

Plant Design System (PDS) Piping Component Data

Codelists
540
541
542
590

=
=
=
=

'BLTP
'BLE'
'MJBE'
'HTP

(541-549)'[Bell end termination type]


[Push-on bell end]
[Mechanical joint bell end]
(581-599)'[Hole end termination type]

Use
591
600
601
650
651

591-599 for welded ends only


= 'HCE'
[Circular hole end]
= 'NTP
(600-605)'[Null termination type]
= 'NE'
[Null end]
= 'UDTP
(651-659)'[User defined termination type]
= 'UD'
[User defined end] (When a "UD"
preparation end is detected by the
system in the piping materials
class, it will prompt the User to define
the actual CP preparation to use. The
value provided by the User will be used
for initial placement of the component
as well as for subsequent recreations of
the piping system.)

CL332, Schedule / Thickness Override


Schedule/thickness override values for metric projects must
have codelist values between 499 and 1000.

Plant Design System (PDS) Piping Component Data

643

Codelists
1
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
100
101
102
103
110

644

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Blank]
'.0625'
'.125'
'.1875'
'.25'
'.3125'
'.375'
'.4375'
'.5'
'.5625'
'.625'
'.6875'
'.75'
'.8125'
'.875'
'.9375'
'1'
'1.0625'
'1.125'
'1.1875'
'1.25'
'1.3125'
'1.375'
'1.4375'
'1.5'
'1.5625'
'1.625'
'1.6875'
'1.75'
'1.8125'
'1.875'
'1.9375'
'2'
'2.0625'
'2.125'
'2.1875'
'2.25'
'2.3125'
'2.375'
'2.4375'
'2.5'
'2.5625'
'2.625'
'2.6875'
'2.75'
'2.8125'
'2.875'
'2.9375'
'3'
'S-5S'
'S-10S'
'S-40S'
'S-80S'
'S-10'

Plant Design System (PDS) Piping Component Data

Codelists
111
112
113
114
115
116
117
118
119
130
131
132

=
=
=
=
=
=
=
=
=
=
=
=

'S-20'
'S-30'
'S-40'
'S-60'
'S-80'
'S-100'
'S-120'
'S-140'
'S-160'
'S-STD'
'S-XS'
'S-XXS'

CL340, Safety Classification (99)


1
2
3
4
5
6
7
8
9
10

=
=
=
=
=
=
=
=
=
=

[Blank]
'SC1'
'SC2'
'SC3'
'SC4'
'SC5'
'SC6'
'SC7'
'SC8'
'SC9'

CL360, Stress Analysis Requirements (15)


In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1
2
3
4

=
=
=
=

[Blank]
'ANR =Analysis not required'
'ATBP=Analysis to be performed'
'AC =Analysis completed'

CL365, Reporting Requirements (25)


In editing this codelist set, do not change the meaning of existing
codelist values.
1 = 'Reportable by MTO'
2 = 'Not Reportable by MTO'

Plant Design System (PDS) Piping Component Data

645

Codelists

CL366, Requirement to Reconstruct (10)


In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed. Labels
always require that only values to the right of the "=" sign be
displayed.
0 = 'None'
1 = 'reconstruct'
2 = 're-calculate'

CL380, Piping Component Type (2500)


1
2
3
4
5
6
8

646

=
=
=
=
=
=
=

[Blank]
'Piping'
'Piping'
'Piping'
'Piping'
'Hose'
'Tubing'

[Primary single line]


[Secondary single line]
[Primary double line]
[Double line]

Plant Design System (PDS) Piping Component Data

Codelists
18
19
20
21
22
23
24
25
28
29
30
31
33
34
35
36
39
43
47
49
50
51
54
55
56
57
58
59
60
67
68
70
71
73
74
75
79
86
89
90
93
97
98
99

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Gate valve'
'Extended body gate valve'
'Conduit gate valve'
'Blank gate valve'
'3-way valve'
'Ball valve'
[2-way]
'2-way valve'
'3-way ball valve'
'Globe valve'
[2-way]
'Angle globe valve'
[2-way]
'3-way globe valve'
'Y globe valve'
'Plug valve'
[2-way]
'4-way valve'
'3-way plug valve'
'4-way plug valve'
'Needle valve'
'Butterfly valve'
'Diaphragm valve'
'Knife gate valve'
'Slide valve'
[2-way]
'3-way slide valve'
'Angle valve'
'Check valve'
'Wafer check valve'
'Angle check valve'
'Stop check valve'
'Angle stop check valve'
'Y stop check valve'
'Backflow preventer'
'Automatic recirculation valve'
'Angle blowdown valve'
'Y blowdown valve'
'Pinch valve'
'Float valve'
'Foot valve'
'Tank drain valve'
'Deluge valve'
'Hose valve'
'Angle hose valve'
'Vent/drain valve'
'Instrument root valve'
'3-way instrument root valve'
'4-way instrument root valve'

Plant Design System (PDS) Piping Component Data

647

Codelists
117
119
120
122
124
126
127
128
129
130
131
132
133
135
137
138
139
140
141
142
143
144
148
151
152
155
156
157
159
160
162
163
165
167
169
171
172
173
175
176
177
179
181
182
184
189
191
192
193
195
196
198
200
202

648

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Flange'
'Reducing flange'
'Expander flange'
'Orifice flange'
'Blind flange'
'Open spectacle blank'
'Closed spectacle blank'
'Blank disc'
'Blind spacer'
'Tapered spacer'
'Open spacer'
'End'
'Head'
'Plug'
'Cap'
'Diameter change'
'Concentric diameter change'
'Eccentric diameter change'
'Coupling/connector'
'Half coupling'
'Concentric reducer'
'Eccentric reducer'
'Reducing coupling'
'Concentric swage'
'Eccentric swage'
'Union'
'Orifice union'
'Dielectric union'
'Hose connection'
'Bushing'
'Reducing insert'
'Pipe bend'
'5.625 deg elbow'
'11.25 deg elbow'
'22.5 deg elbow'
'<45 deg direction change'
'45 deg direction change'
'45 deg elbow'
'45 deg LR elbow'
'45 deg long tangent elbow'
'45 deg 3D elbow'
'45 deg union elbow'
'45 deg street elbow'
'45 deg short elbow'
'45 deg long elbow'
'60 deg elbow'
'45-90 deg direction change'
'90 deg direction change'
'90 deg elbow'
'90 deg SR elbow'
'90 deg LR elbow'
'90 deg LR long tangent elbow'
'90 deg reducing elbow'
'90 deg 3D elbow'

Plant Design System (PDS) Piping Component Data

Codelists
204
206
207
209
210
216
218
220
222
223
224
229
231
233
237
239
240
242
243
246
249
251
253
260
262
264
265
267
268
269
270
275
277
278
279
285
287
288
289
290
291
292
293
294
295
297
299
303
304
310
312
313

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'90 deg union elbow'


'90 deg street elbow'
'90 deg reducing street elbow'
'90 deg short elbow'
'90 deg long elbow'
'180 deg return'
'180 deg SR return'
'180 deg LR return'
'180 deg close return'
'180 deg medium return'
'180 deg open return'
'Miter'
'45 deg miter'
'90 deg miter'
'Tee'
'Reducing branch tee'
'Reducing run and branch tee'
'On-run union tee'
'On-branch union tee'
'Street tee'
'Reducing instrument tee'
'Drip ring tee'
'Basin tee'
'True Y'
'Lateral'
'Reducing branch lateral'
'Reducing run and branch lateral'
'90 deg short Y-branch'
'90 deg reducing short Y-branch'
'90 deg long Y-branch'
'90 deg reducing long Y-branch'
'Cross'
'Reducing branches cross'
'Reducing run and branches cross'
'Basin cross'
'Saddle'
'Sweepolet'
'Weldolet'
'Sockolet'
'Thredolet'
'Nippolet'
'Elbolet'
'Latrolet'
'Endolet'
'Reinforcing pad'
'Reinforcing weld'
'Buttweld'
'Branch nipple'
'In-line nipple'
'Gasket'
'Stud'
'Nut'

Plant Design System (PDS) Piping Component Data

649

Codelists
315
316
317
318
319
320
324
325
327
338
339
340
344
345
346
352
353
354
374
380

650

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Fire monitor'
'Elevated fire monitor'
'Remotely operated fire monitor'
'Foam monitor'
'Elevated foam monitor'
'Remotely operated foam monitor'
'Fire hydrant'
[2-way]
'Fire hydrant w/monitor nozzle' [2-way]
'3-way fire hydrant'
'Hose reel'
'Hose rack station'
'Foam chamber'
'Wet sprinkler'
'Pre-action sprinkler'
'Spray sprinkler'
'Eye wash'
'Safety shower'
'Safety shower and eye wash'
'Siamese'
[2-way]
'90 deg siamese'
[2-way]

Plant Design System (PDS) Piping Component Data

Codelists
513
515
516
517
518
519
521
523
524
525
527
529
533
535
540
542
544
546
548
552
556
557
559
561
563
564
565
567
569
571
576
582
583
584
586
588
590
611
613

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Flame arrestor'
'Hammer arrestor'
'Vent silencer'
'In-line silencer'
'Vent'
'Exhaust head'
'Breather vent'
'Free vent w/o screen'
'Free vent w/screen'
'Motor operated valve'
'Mixing T'
'Spray nozzle'
'Removable spool'
'Swing elbow'
'Expansion joint'
'Hinged expansion joint'
'Swivel joint'
'Mechanical coupling'
'Flexible hose'
'Sample cooler'
'Strainer/filter'
'Single basket strainer'
'Duplex basket strainer'
'T strainer'
'Y strainer'
'Temporary strainer'
'Basket strainer'
'Cone strainer'
'Flat plate strainer'
'Sump strainer'
'Filter'
'Steam trap'
'Float steam trap'
'Inverted bucket steam trap'
'Thermostatic steam trap'
'Thermodynamic steam trap'
'Impulse steam trap'
'Generic component'
'Pip seg heat tracing brk/comp 2'

Plant Design System (PDS) Piping Component Data

651

Codelists
747
748
749
750
823
824
825
833
873
874
875
876
877
878
879
880
909
911
913
923
927
1008
1018
1019
1020
1038
1039
1040
1041
1042
1043
1044
1045
1047
1049
1053
1068
1069
1070
1071
1072
1073
1074
1075
1079
1083
1108
1117

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Air utility station'


'Nitrogen utility station'
'Water utility station'
'Steam utility station'
'Vent/drain detail 1'
'Vent/drain detail 2'
'Vent/drain detail 3'
'Vent/drain detail H'
'Connection detail 1'
'Connection detail 2'
'Connection detail 3'
'Connection detail 4'
'Connection detail 5'
'Connection detail 6'
'Connection detail 7'
'Connection detail 8'
'Anchor'
'1-way support'
'2-way support'
'Spring support'
'Damping support'
'Tie-in marker'
'Utility connector'
'Drain connector'
'Utility station connector'
'TRM off-dwg piping connector'
'TLM off-dwg piping connector'
'TTM off-dwg piping connector'
'TBM off-dwg piping connector'
'FRM off-dwg piping connector'
'FLM off-dwg piping connector'
'FTM off-dwg piping connector'
'FBM off-dwg piping connector'
'Utility off-dwg pip connector'
'To off-vol piping connector'
'From off-vol piping connector'
'TRM off-unit piping connector'
'TLM off-unit piping connector'
'TTM off-unit piping connector'
'TBM off-unit piping connector'
'FRM off-unit piping connector'
'FLM off-unit piping connector'
'FTM off-unit piping connector'
'FBM off-unit piping connector'
'To off-site piping connector'
'From off-site piping connector'
'Piping node marker'
'Terminator piping connector'

Entries above 1500 are reserved for DIN components.

652

Plant Design System (PDS) Piping Component Data

Codelists
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Valve generic'
'Angle plug valve'
'Non-return valve'
'Check valve'
'Valve with continous action'
'4-way globe valve'
'4-way valve,generic'
'Steam throttling angle valve'
'Steam throttling 3-way globe valve'
'Butterfly valve with continous action'
[Blank]
[Blank]
'Globe valve with continous action'
'Gate valve with continous action'
'Plug valve with continous action'
'Angle globe valve with continous action'
'Free wheel check valve'
'Safety check valve'
'Fire safety butterfly valve'
'Aeration and deaeration armature'
'Angle ball valve'
'4-way ball valve'
'Taper plug valve'
'Taper angle plug valve'
'3-way taper plug valve'
'4-way taper plug valve'
'Flat seal bottom'
'Blank disk'
'Flange connection'
'Screwed connection'
'Angle diaphragm valve'

Plant Design System (PDS) Piping Component Data

653

Codelists
1533
1534
1535
1536
1537
1538
1539
1540
1542
1543
1544
1545
1546
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1587
1588
1590

654

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Safety valve'
'Safety valve regulated with spring'
'Safety valve regulated with weight'
'Angle safety valve'
'Angle safety valve regulated with spring'
'Rupture disk'
'Aeration with screw cap'
'Inspection glass'
'Aeration with plug'
'Flanged aeration'
'90 deg earation'
'180 deg earation'
'Tapered filter'
'Discharge valve with blind flange'
'Discharge valve'
'Discharge with blind flanged gate valve'
'Discharge with gate valve'
'Bellow expansion joint'
'Lyra expansion joint'
'90 degree elbow for JP'
'T connection for JP'
'Flange between JP'
'Valve for connecting JP media'
'Blindflange JP'
'Skewed connection JP'
'Y connection JP'
'flanged connection segment/comp type 1'
'flanged connection segment/comp type 2'
'flanged connection segment/comp type 3'
'flanged connection segment/comp type 4'
'Flange from JP to normal pipe'
'Valve for JP media supply'
'Flange connection for JP'
'Bypass for JP media'
'Flange for bypassing JP'
'Syphon'
'Ball linkage'
'Mixing component'
'Flow straightener'
[Blank]
'Spring clip'
'Fire extinguishing equipment powder'
'Fire extinguishing equipment halogen'
'Fire extinguishing equipment carbonic acid'
'Fire extinguishing equipment foam'
'Fire extinguishing equipment floor connection'
'Fire extinguishing equipment overhead conn.'
'Fire extinguishing connector'
'Fire extinguishing water supply'
'Fire brigade accessory'
'Hydrant ground floor'
'Hydrant overhead'
'Wall hydrant'
'Sprinkler equipment'

Plant Design System (PDS) Piping Component Data

Codelists
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604

=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Flooding spray equipment'


'Spraying equipment'
'Refrigerating unit'
'Globe valve with open function'
'Angle valve with open function'
'Clamp joint'
'Taper pipe thread'
[Blank]
'Socket joint'
'Taper pipe joint'
'Cool box'
'Ball float valve'
'Ball check valve'
'Flanged joint'

CL390, Action (40)


1
2
3
5
6
10
11
15
16
18
19
20
24
30
31
34
35

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Blank]
'NO'
'NC'
'CSO'
'CSC'
'LO'
'LC'
'FO'
'FC'
'FL'
'FLO'
'FLC'
'FI'
'EO'
'EC'
'DEO'
'DEC'

[Normally open]
[Normally closed]
[Car seal open]
[Car seal closed]
[Locked open]
[Locked closed]
[Fail open]
[Fail closed]
[Fail locked]
[Fail locked open]
[Fail locked closed]
[Fail indeterminate]
[Energize to open]
[Energize to close]
[De-energize to open]
[De-energize to close]

CL400, Option (999)


When editing this codelist set, do not change the meaning of
the indicated codelist ranges. The number of codelist entries must
not exceed 5000, and the maximum number used in these entries must not be
greater
than 10,000.
1 = [Blank]
2 = 'Bypass PMC'

Use to bypass PMC access

Plant Design System (PDS) Piping Component Data

655

Codelists
Types Options, 11-19
11 = 'Type 1'
12 = 'Type 2'
13 = 'Type 3'
14 = 'Type 4'
15 = 'Type 5'
16 = 'Type 6'
17 = 'Type 7'
18 = 'Type 8'
19 = 'Type 9'
Valve Type Options, 21-60
21 = 'Red port'
24 = 'Full port'
27 = 'Tight SO'
30 = 'Dbl disc'
32 = 'Y pattern'
33 = 'Wafer'
34 = 'Lug'
36 = 'Single flange'
38 = '1/8" hole'
39 = 'Non lube'
40 = '3/16" hole'
41 = '1/4" hole'
42 = 'Lube'
43 = 'Quick close'
44 = 'Quick open'
45 = 'Al chk'
46 = 'Excess flow'
48 = 'Limit stop'
49 = 'Hor chk'
50 = 'Vert chk'
56 = 'Tap lcn G'
57 = 'Tap lcns G & H'
58 = 'Tap lcns G & I'
59 = 'Tap lcns G & J'
60 = 'Tap lcns G & K'

[Reduced port valve]


[Full port valve]
[Tight shutoff valve]
[Double disc valve]
[Y pattern valve]
[Wafer valve]
[Lug pattern]
[Single flange valve]
[1/8" diam hole in flapper]
[Non-lubricated valve]
[3/16" diam hole in flapper]
[1/4" diam hole in flapper]
[Lubricated valve]
[Quick closing valve]
[Quick opening valve]
[Alarm check valve]
[Excess flow check valve]
[Limit stop valve]
[Horizontal check valve]
[Vertical check valve]
[Tap at location G]
[Tap at locations G & H]
[Tap at locations G & I]
[Tap at locations G & J]
[Tap at locations G & K]

Valve Operator Options, 61-100


61 = 'HW op'
[Handwheel]
64 = 'WR op'
[Wrench operator]
67 = 'LV op'
[Lever operator]
70 = 'T op'
[T-handle operator]
73 = 'GTM op'
[Gear operator, top mounted handwheel]
76 = 'GSM op'
[Gear operator, side mounted handwheel]
79 = 'EM op'
[Electric motor operator]
82 = 'ESHW op'
[Extended stem and handwheel]
88 = 'ESGTM op'
[Extended stem and gear operator, top mounted
handwheel]
91 = 'EXGSM op'
[Extended stem and gear operator, side mounted
handwheel]
100 = 'Post ind'
[Post indicator]

656

Plant Design System (PDS) Piping Component Data

Codelists
Bend
121
124
127
130
133
134
136

Radius Options, 121-140


= '1D bend'
[1D pipe bend]
= '1.5D bend'
[1.5D pipe bend]
= '3D bend'
[3D pipe bend]
= '4D bend'
[4D pipe bend]
= '5D bend'
[5D pipe bend]
= '6D bend'
[6D pipe bend]
= '10D bend'
[10D pipe bend]

Head
141
143
145

Type Options, 141-150


= 'Hemi hd'
= 'Ellip hd'
= '2:1 hd'

Miter Options, 151-160


151 = '1 cut'
152 = '2 cuts'
153 = '3 cuts'
154 = '4 cuts'

[Hemispherical head]
[Ellipsoidal head]
[2:1 elliptical head]
[1-cut miter]
[2-cuts miter]
[3-cuts miter]
[4-cuts miter]

Miscellaneous Options, 161-170


161 = 'Housing'
[Housing]
163 = 'After vlv'
[After isolating valve]
165 = 'Match branch nipple' [Match branch nipple]
167 = 'Straight ends'
[Straight ends]
168 = 'Hor'
[Horizontal]
169 = 'Vert'
[Vertical]
Flange
171 =
173 =
175 =
177 =
179 =
181 =
183 =
185 =
187 =
189 =
191 =
193 =
195 =
196 =
197 =

Type Options, 171-200


'WN'
[Weld neck flange]
'LWN'
[Long weld neck flange]
'SO'
[Slip-on flange]
'LJ'
[Lap joint flange]
'PL'
[Plate flange]
'SS-SO'
[Short-stub-end, slip-on flange]
'SS-LJ'
[Short-stub-end, lap joint flange]
'SS-PL'
[Short-stub-end, plate flange]
'LS-SO'
[Long-stub-end, slip-on flange]
'LS-LP'
[Long-stub-end, lap joint flange]
'Filler'
[Filler flange]
'Socket'
[Socket flange]
'SW'
[Socketwelded flange]
'SW Red'
[Socketwelded reducing flange]
'Thd'
[Threaded flange]

Plant Design System (PDS) Piping Component Data

657

Codelists
Bolted End Options, 201-400
202 = 'FE'
[Flanged end]
211 = 'FFFE'
[Flat-face flanged end]
216 = 'FFFEWG'
[Flat-face flanged end w/ integral gasket]
221 = 'RFFE'
[Raised-face flanged end]
226 = 'RFFEWG'
[Raised-face flanged end w/ integral gasket]
231 = 'RJFE'
[RTJ-face flanged end]
241 = 'STFE'
[Small-tongue-face flanged end]
242 = 'LTFE'
[Large-tongue-face flanged end]
243 = 'SMFE'
[Small-male-face flanged end]
244 = 'LMFE'
[Large-male-face flanged end]
251 = 'SGFE'
[Small-groove-face flanged end]
252 = 'LGFE'
[Large-groove-face flanged end]
253 = 'SFFE'
[Small-female-face flanged end]
254 = 'LFFE'
[Large-female-face flanged end]
261 = 'FFLFE'
[Flat-face lap-flanged end]
271 = 'RFLFE'
[Raised-face lap-flanged end]
281 = 'RJLFE'
[RTJ-face lap-flanged end]
291 = 'STLFE'
[Small-tongue-face lap-flanged end]
292 = 'LTLFE'
[Large-tongue-face lap-flanged end]
293 = 'SMLFE'
[Small-male-face lap-flanged end]
294 = 'LMLFE'
[Large-male-face lap-flanged end]
301 = 'SGLFE'
[Small-groove-face lap-flanged end]
302 = 'LGLFE'
[Large-groove-face lap-flanged end]
303 = 'SFLFE'
[Small-female-face lap-flanged end]
304 = 'LFLFE'
[Large-female-face lap-flanged end]
311 = 'FFTBE'
[Flat-face thru-bolted end]
316 = 'FFTBEWG'
[Flat-face thru-bolted end w/ integral
gasket]
321 = 'RFTBE'
[Raised-face thru-bolted end]
326 = 'RFTBEWG'
[Raised-face thru-bolted end w/ integral
gasket]
331 = 'RJTBE'
[RTJ-face thru-bolted end]
346 = 'MRJTBEWG'
[Male RTJ-face thru-bolted end w/ integral
gasket]
351 = 'FFTBCSE'
[Flat-face thru-bolted-w/-cap-screws end]
356 = 'FFTBCSEWG'
[Flat-face thru-bolted-w/-cap-screws end w/
integral gasket]
361 = 'RFTBCSE'
[Raised-face thru-bolted-w/-cap-screws end]
366 = 'RFTBCSEWG'
[Raised-face thru-bolted-w/-cap-screws end
w/ integral gasket]
371 = 'RJTBCSE'
[RTJ-face thru-bolted-w/-cap-screws end]
381 = 'FFFTBE'
[Flat-full-face thru-bolted end]
386 = 'FFFTBEWG'
[Flat-full-face thru-bolted end w/ integral
gasket]
391 = 'MJE'
[Mechanical joint end]

658

Plant Design System (PDS) Piping Component Data

Codelists
Male
401
402
411
421
431
441
451
455
461
471
481
491
493
495

End Options, 401-500


= 'BE'
= 'OLET'
= 'TBE'
= 'MFE'
= 'MTE'
= 'MGE'
= 'MQCE'
= 'MCE'
= 'MFRE'
= 'MHE'
= 'SPE'
= 'PE'
= '3"FFPE'
= '6"FFPE'

Female
501 =
521 =
541 =
561 =
581 =
601 =
621 =
641 =
642 =
691 =

End Options, 501-696


'SE'
'SWE'
'FTE'
'FGE'
'FQCE'
'FFRE'
'FHE'
'BLE'
'MJBE'
'HCE'

[Beveled end]
[Olet beveled end]
[Tapered and beveled end]
[Male flared end]
[Male threaded end]
[Male grooved end]
[Male quick connect end]
[Male clamp end]
[Male ferrule end]
[Male hose end]
[Spigot end]
[Plain end] [391-399]
[Plain end, 3" field fit]
[Plain end, 6" field fit]
[Socket end]
[Socketwelded end]
[Female threaded end]
[Female grooved end]
[Female quick connect end]
[Female ferrule end]
[Female hose end]
[Push-on bell end]
[Mechanical joint bell end]
[Circular hole end]

User Defined Null End Options, (697-697)


697 = 'NE'
[Null end]
User Defined End Options, 699-699
699 = 'UD'
[User defined]
Mixed End Options, 701-717
701 = 'FE x MJE'
702 = 'FE x BE'
703 = 'FE x PE'
705 = 'BE x MTE'
706 = 'BE x PE'
707 = 'BE x SWE'
708 = 'BE x FTE'
709 = 'OLET x FTE'
710 = 'MTE x PE'
711 = 'PE x MTE'
712 = 'PE x SWE'
713 = 'PE x FTE'
714 = 'SWE x FTE'
715 = 'OLET x SWE'
716 = 'MTE x FTE'
717 = 'FE x FTE'

[Flanged end by mechanical joint end]


[Flanged end by beveled end]
[Flanged end by plain end]
[Beveled end by male threaded end]
[Beveled end by plain end]
[Beveled end by socketwelded end]
[Beveled end by female threaded end]
[Olet beveled end by female threaded end]
[Male threaded end by plain end]
[Plain end by male threaded end]
[Plain end by socketwelded end]
[Plain end by female threaded end]
[Socketwelded end by female threaded end]
[Olet beveled end by socketwelded end]
[Male threaded end by female threaded end]
[Flanged end by female threaded end]

The following options have been modified to include mm in lengths


and add British metric pressure ratings (PN).

Plant Design System (PDS) Piping Component Data

659

Codelists
Nipple
720 =
721 =
722 =
723 =
724 =
725 =
726 =
727 =
728 =
729 =
730 =
731 =
732 =
733 =
734 =
735 =
736 =
737 =
738 =
739 =
740 =
741 =
742 =
743 =
744 =
745 =
746 =
747 =
748 =
749 =
750 =
751 =
752 =
753 =
754 =
755 =

660

Options, 718-755
'3.0"(75mm) BE'
'3.0"(75mm) MTE'
'3.0"(75mm) PE'
'3.0"(75mm) BE x MTE'
'3.0"(75mm) BE x PE'
'3.0"(75mm) MTE x PE'
'4.0"(100mm) BE'
'4.0"(100mm) MTE'
'4.0"(100mm) PE'
'4.0"(100mm) BE x MTE'
'4.0"(100mm) BE x PE'
'4.0"(100mm) MTE x PE'
'5.0"(125mm) BE'
'5.0"(125mm) MTE'
'5.0"(125mm) PE'
'5.0"(125mm) BE x MTE'
'5.0"(125mm) BE x PE'
'5.0"(125mm) MTE x PE'
'6.0"(150mm) BE'
'6.0"(150mm) MTE'
'6.0"(150mm) PE'
'6.0"(150mm) BE x MTE'
'6.0"(150mm) BE x PE'
'6.0"(150mm) MTE x PE'
'7.0"(175mm) BE'
'7.0"(175mm) MTE'
'7.0"(175mm) PE'
'7.0"(175mm) BE x MTE'
'7.0"(175mm) BE x PE'
'7.0"(175mm) MTE x PE'
'8.0"(200mm) PE'
'9.0"(225mm) PE'
'1O.0"(250mm) PE'
'11.0"(275mm) PE'
'12.0"(300mm) PE'
'HEX'

[3.0" long, BE]


[3.0" long, MTE]
[3.0" long, PE]
[3.0" long, BE x MTE]
[3.0" long, BE x PE]
[3.0" long, MTE x PE]
[4.0" long, BE]
[4.0" long, MTE]
[4.0" long, PE]
[4.0" long, BE x MTE]
[4.0" long, BE x PE]
[4.0" long, MTE x PE]
[5.0" long, BE]
[5.0" long, MTE]
[5.0" long, PE]
[5.0" long, BE x MTE]
[5.0" long, BE x PE]
[5.0" long, MTE x PE]
[6.0" long, BE]
[6.0" long, MTE]
[6.0" long, PE]
[6.0" long, BE x MTE]
[6.0" long, BE x PE]
[6.0" long, MTE x PE]
[7.0" long, BE]
[7.0" long, MTE]
[7.0" long, PE]
[7.0" long, BE x MTE]
[7.0" long, BE x PE]
[7.0" long, MTE x PE]
[8.0" long, PE]
[9.0" long, PE]
[10.0" long, PE]
[11.0" long, PE]
[12.0" long, PE]
[Hexagon]

Plant Design System (PDS) Piping Component Data

Codelists
Rating
756 =
757 =
758 =
759 =
760 =
761 =
762 =
763 =
764 =
765 =
766 =
767 =
768 =
769 =
770 =
773 =
774 =
775 =
776 =
777 =
778 =
781 =
782 =
785 =
789 =
790 =
792 =
794 =
795 =
796 =
797 =
801 =
805 =
809 =
813 =
815 =
817 =
821 =
823 =
827 =
831 =
835 =
836 =
838 =
840 =

Options, 756-849
'CL25'
'PN2.5'
'CL50'
'CL75'
'86#'
'CL100'
'CL125'
'CL150'
'175#'
'PN6'
'PN10'
'CL200'
'PN16'
'CL250'
'275#'
'CL300'
'350#'
'PN25'
'PN40'
'CL400'
'PN64'
'CL600'
'PN100'
'CL800'
'CL900'
'PN160'
'1000#'
'PN250'
'PN320'
'PN400'
'CL1500'
'CL2000'
'CL2500'
'CL3000'
'CL4500'
'CL5000'
'CL6000'
'CL9000'
'CL10000'
'CL15000'
'CL20000'
'CL30000'
'SCH 40'
'SCH 80'
'GRAVHD'

Plant Design System (PDS) Piping Component Data

661

Codelists
Thickness Options, 851-869
851 = '0.0625"(2mm) thck'
852 = '0.125"(3mm) thck'
853 = '0.1875"(4mm) thck'
854 = '0.25"(6mm) thck'
855 = '0.3125"(8mm) thck'
856 = '0.375"(9mm) thck'
857 = '0.4375"(10mm) thck'
858 = '0.5"(12mm) thck'
859 = '0.5625"(14mm) thck'
860 = '0.625"(16mm) thck'
861 = '0.6875"(18mm) thck'
862 = '0.75"(20mm) thck'
863 = '0.8125"(21mm) thck'
864 = '0.875"(22mm) thck'
865 = '0.9375"(24mm) thck'
866 = '1.0"(25mm) thck'

662

End Finish Options, 870-879


870 = '63 Ra'
871 = '60-100 Ra'
873 = '80-150 Ra'
875 = '200 Ra'
877 = 'Stock'

[63 Ra finish]
[60-100 Ra finish]
[80-150 Ra finish]
[200 Ra finish]
[Stock-finish]

Gasket
880 =
881 =
882 =
883 =
884 =
885 =
886 =
887 =
894 =

[Flat gasket]
[Flat full face gasket]
[Corrugated gasket]
[Flat double jacketed gasket]
[Corrugated double jacketed gasket]
[Ring gasket]
[Spiral-wound gasket]
[MSS-SP-44 gasket]
[Special gasket]

Options, 880-899
'F gskt'
'FFF gskt'
'C gskt'
'FDJ gskt'
'CDJ gskt'
'R gskt'
'SW gskt'
'MSS gskt'
'SP gskt'

Stud & Nut Options, 900-909


900 = 'Spec bolt'

[Special bolting]

ID Basis Options, 910-910


910 = 'ID basis'

[Dimensions based on inside diameter]

Plant Design System (PDS) Piping Component Data

Codelists
Code Options, 911-989
912 = 'ANSI-B16.12'
[Cast iron drainage fittings]
915 = 'ANSI-B16.15'
[Cast bronze fittings]
922 = 'ANSI-B16.22'
[Copper solder joint pressure fittings]
923 = 'ANSI-B16.23'
[Copper solder joint drainage fittings]
924 = 'ANSI-B16.24'
[Bronze flanges]
929 = 'ANSI-B16.36'
[Orifice flanges]
930 = 'ANSI-B16.42'
[Ductile iron flanges and fittings]
933 = 'ANSI-B1.20.3'
[Dryseal pipe threads]
937 = 'ANSI-B1.20.7'
[Hose coupling screw threads]
945 = 'ASTM-A74'
[Cast iron soil pipe and fittings]
949 = 'AWWA-C110'
[Iron fittings]
950 = 'AWWA-C115'
[Iron pipe and fittings]
955 = 'AWWA-C151'
[Ductile iron pipe]
960 = 'AWWA-C207 Cl.B & D, ring' [Steel slip-on flanges CL86, CL150,
CL175]
961 = 'AWWA-C207 Cl.B & D, hub'
[Steel slip-on flanges CL86, CL150,
CL175]
962 = 'AWWA-C207 Cl.E, hub'
[Steel slip-on flanges CL275]
970 = 'API-5LE'
[Polyethylene fittings]
975 = 'API-6A'
[Wellhead flanges and fittings]
979 = 'API-605'
[API-605 flanges]
980 = 'MSS-SP-44-NB'
[MSS non-blind flanges]
981 = 'MSS-SP-44-B'
[MSS blind flanges]
Vendor
990 =
991 =
992 =
993 =
994 =
995 =
996 =
997 =
998 =
999 =

Options, 990-999
'Tube-Turn'
'Dow'
'Aloyco'
'Yarway'
'Teledyne Farris 1'
'R & G Sloane'
'American DI Pipe'
'Gladding McBean' [Vitrified clay S-XS pipe and fittings]
'Taylor Forge'
'ITT VALVES'

European DIN Standards


1001 = 'Spacer length 10 mm'
1002 = 'Spacer length 15 mm'
1003 = 'Spacer length 20 mm'
1004 = 'Spacer length 25 mm'
1005 = 'Spacer length 30 mm'
1006 = 'Spacer length 35 mm'
1007 = 'Spacer length 40 mm'
1008 = 'Spacer length 45 mm'
1009 = 'Spacer length 50 mm'
1010 = 'Spacer length 60 mm'
1011 = 'Spacer length 70 mm'
1012 = 'Spacer length 80 mm'
1013 = 'Spacer length 90 mm'
1014 = 'Spacer length 100 mm'

Plant Design System (PDS) Piping Component Data

663

Codelists

CL420, Piping Component Type/Source (25)


This codelist defines the type of piping component involved
and the source of the data used in its definition. In editing this
codelist set, do not change the meaning of existing codelist values.
0
1
2
3
4
5
6
7
8

=
=
=
=
=
=
=
=
=

'Piping
'Piping
'Piping
'Piping
'Piping
'Piping
'Piping
'Branch
'Branch

cmdty component from PMC'


cmdty component from User'
flanged cmdty component from PJS'
cmdty component from branch table'
specialty component from PJS'
specialty component from User - spec data input'
specialty component from User - no spec data input'
reinforcement from user'
reinforcement from branch table'

CL425, Piping/Tubing Type (25)


In editing this codelist set, do not change the meaning of
existing codelist values.
1 = 'Piping'
2 = 'Tubing'
3 = 'Hose'

CL430, Instrument Component Type/Source (25)


This codelist defines the type of instrument component
involved and the source of the data used in its definition. In
editing this codelist set, do not change the meaning of existing
codelist values.
0 = 'Instr specialty component from PJS'
1 = 'Instr specialty component from User - spec data input'
2 = 'Instr specialty component from User - no spec data input'

CL499, Piping Notes (999)


1 = [Blank]

664

Plant Design System (PDS) Piping Component Data

Codelists
Notes Applicable to the Piping Materials Class, 2-199
3 = 'Valve and flange protectors required.'
22 = 'Valves shall be in accordance with NACE MR-01-75.'
50 = 'The Manufacturer shall be consulted for special bolting
requirements where both the design temperature is above 800 degF
and the valve bonnet is insulated.'
54 = 'Unions shall not be used.'
56 = 'Gasket seating surfaces shall have 125 Ra surface finish.'
57 = 'Unions shall not be used. Gasket seating surfaces shall
have 125 Ra surface finish.'
58 = 'Unions shall not be used. Gasket seating surfaces shall
have 125 Ra surface finish. Valves shall be in accordance with
NACE MR-01-75.'
60 = 'All welds shall use compatible rod and shall be PWHT
regardless of thickness and/or joint configuration.'
61 = 'All welds shall use compatible rod and shall be PWHT
regardless of thickness and/or joint configuration unless
specifically approved by Contractor and permitted by
ANSI-B31.3 Code.'
62 = 'Refer to AWWA-C151 for suitable installation types.'
63 = 'Underground pipe and fittings shall be coated and wrapped.'
64 = 'Pipe and fittings shall be cement lined.'
79 = 'Extra thickness has been included.'
80 = 'All components shall be bored to suit thickness of pipe.
Taper bore flanges to a depth of 1.5 inches as required to match
inside diameter of all connecting pipingand valves. Welds
shall be ground smooth to match inside diameter of pipe.'
82 = 'Use long radius bends with radius as specified on the P&IDs
for all changes in direction.'
83 = 'Do not allow galvanized or any other zinc bearing material
to come in contact with stainless steel or high nickel
alloys components. This includes supports, nipples, weld
splatter, wire, bolts, paint, or any other type of contact.'

Plant Design System (PDS) Piping Component Data

665

Codelists
Notes Applicable to a Piping Component, 200-499
201 = 'To be used only where specifically required.'
202 = 'Use between blind flange and gasket.'
203 = 'Use for thermowell connections.'
204 = 'Use for hydrostatic vents and drains. Seal (bridge) weld
after testing in accordance with piping job specifications.'
205 = 'Use bends for direction changes.'
206 = 'Use at flanged equipment connections.'
207 = 'Use for hydrostatic vents and drains.'
208 = 'Use threaded plug for vent/drain valve; do not seal weld plug.'
209 = 'To be used only where specifically required and/or between
blind flange and gasket.'
210 = 'Use threaded plug for vent/drain valve; do not seal weld
plug. Vent/drain and instrument root valves with 1 inch nominal
diameter in carbon steel and 9Cr-1Mo materials provide more
than 3/16 inch but less than 1/4 inch CA.'
211 = 'Use of this component under certain pressure/temperature
conditions may provide less than 3/16 inch CA.'
214 = 'Use where full port is required.'
220 = 'Install in the horizontal position only.'
221 = 'Valve shall be in accordance with NACE MR-01-75.'
222 = 'Use 0.75 inch diameter only at orifice flange taps.'
223 = 'Use 0.5 inch diameter only at orifice flange taps.'
224 = 'To be used only where specifically required. Valve sizes
16" and larger require electric motor operators.'
253 = 'Use of unions and threaded fittings shall be limited to a
maximum temperature of 500 degF.'
257 = 'When mating stainless steel flanges to ferritic steel
flanges, use studs corresponding to the ferritic flange.'
259 = 'Double hub fittings are available in 90 degrees and 45
degrees elbows.'
260 = 'Cement lined per AWWA-C205-80. Minimum lining thickness
shall be 0.3125 inch thick. Lining shall be Type II cement per
ASTM-C150 with a minimum 28-day compressive strength of
3000 psi. Lining shall be flush with ends.'
276 = 'Remove internals of valves containing Teflon seats and/or
seals prior to welding or backwelding.'
304 = 'For use in deluge systems.'
325 = 'Do not use over 100 degF.'
326 = 'Do not use over 150 degF.'
328 = 'Do not use over 180 degF.'
329 = 'Do not use over 200 degF.'
330 = 'Do not use over 250 degF.'
331 = 'Do not use over 300 degF.'
332 = 'Do not use over 350 degF.'
333 = 'Do not use over 400 degF.'
334 = 'Do not use over 450 degF.'
335 = 'Do not use over 500 degF.'
336 = 'Do not use over 550 degF.'
337 = 'Do not use over 600 degF.'
338 = 'Do not use over 650 degF.'
339 = 'Do not use over 700 degF.'
340 = 'Do not use over 750 degF.'
341 = 'Do not use over 800 degF.'

666

Plant Design System (PDS) Piping Component Data

Codelists
Notes Applicable to a Piping Specialty, 500-699
Notes Applicable to an Instrument Specialty, 700-899

CL530, Accessory/Item Type (125)


In editing this codelist set, do not change the meaning of
existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1 = [Blank]
Accessory
5 = 'AC
10 = 'A
20 = 'C
30 = 'I
45 = 'PO
50 = 'R
55 = 'S
65 = 'T
75 = 'X
80 = 'Y

Type, 2-99
=Actuator'
=Alarm'
=Controller'
=Indicator'
=Positioner'
=Recorder'
=Switch'
=Transmitter'
=Unclassified'
=Converter'

Item Type, 100-125


101 = 'Equipment nozzle'
103 = 'Piping segment'
105 = 'CV or regulator'
107 = 'Relief device'
109 = 'Other-in-line instrument'
111 = 'Off-line instrument'
113 = 'System function'
115 = 'Instr connector'
117 = 'Function label'
121 = 'Other'

CL550, Operator/Actuator Type (200)


Codelist numbers 2-24 apply to operators for piping
commodity valves whose dimensions are determined from tables whose
names are formed from attributes in the Piping Job Specification.
Codelist numbers 25-40 apply to operators for piping commodity
valves whose dimensions are determined from tables whose names
depend on the commodity codes for the valves. Codelist numbers
41-99 apply to operators and actuators for piping and instrument
specialty valves. Codelist numbers 101-150 should be used for user
defined operators with only primary orientaions, such as handwheels
and post indicators. Codelist numbers 151-200 should be used for
user defined operators with both primary orientations and secondary
orientations, such as levers and T-handles.

Plant Design System (PDS) Piping Component Data

667

Codelists
1 = [Blank]
Operators with Data Derived from Spec Parameters, 2-24
3 = 'Handwheel'
4 = 'Handwheel if GCP > RCP'
5 = 'Handwheel, inclined'
9 = 'Wrench, short'
11 = 'Wrench, long'
17 = 'Lever'
19 = 'T-handle, short'
21 = 'T-handle, long'
Operators with Data Derived from Valve Codes, 25-40
25 = 'Handwheel, special'
27 = 'Wrench, special'
29 = 'Gear, top mounted handwheel'
31 = 'Gear, top mounted inclined handwheel'
33 = 'Gear, side mounted handwheel'
35 = 'Gear, side mounted inclined handwheel'
39 = 'Lever, quick-action'
40 = 'Post indicator'
Actuators, 41-99
41 = 'Diaphragm'
42 = 'Electro-Pneumatic'
43 = 'Press-balanced diaphragm'
45 = 'Regulator'
49 = 'Single acting cylinder'
51 = 'Double acting cylinder'
53 = 'Pilot operated cylinder'
57 = 'Motor'
61 = 'Digital'
65 = 'Electro-hydraulic'
69 = 'Single solenoid'
71 = 'Single solenoid w/reset'
73 = 'Double solenoid'
77 = 'Pilot'
81 = 'Weight'
85 = 'Manual'
89 = 'Spring'
91 = 'Capacitance sensor'
93 = 'Ball float'
95 = 'Displacement float'
97 = 'Paddle wheel'

668

Plant Design System (PDS) Piping Component Data

Codelists

CL570, Design Standard (200)


1
10
11
12
13
20
21
22
23
24
25
28
29
38
50
51
60
61

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Blank]
'ASME-I'
[Power Boilers]
'ASME-III'
[Nuclear]
'ASME-VIII-1'
[Unfired Vessels]
'ASME-VIII-2'
[Unfired Vessels]
'ASME Fld Mets & AGA Rpt 3' [Instruments]
'ANSI-B31.1'
[Power]
'ANSI-B31.2'
[Fuel Gas]
'ANSI-B31.3'
[Petroleum]
'ANSI-B31.4'
[Oil Transport]
'ANSI-B31.5'
[Refrigeration]
'ANSI-B31.8'
[Gas Transmission]
'ANSI-B31.9'
[Building Services]
'API-2000'
[Tank Venting]
'AWWA'
[Water Services]
'DIN'
'BS806'
'BS3351'

CL572, Wall Thickness Equation


1 = [Blank]
21 = 'ANSI B31.1a-1986'
23 = 'ANSI B31.3-1987'

CL575, Geometry Standard (31999)


The symbol "||" at the end of a description in this document
signifies that the standard has been used in preparing RDB data.
Codelist numbers have been reserved as follows:
o
o
o
o
o
o
o

US practices
European practices 1 (DIN)
European practices 2 (British)
European practices 3 (Finnish, French, etc.
International practices 1 (JIS)
International practices 2 (Australian, etc.)
Company practices

2-6999
7000-11999
12000-16999
17000-19999
20000-24999
25000-27999
28000-31999

1 = [Blank]

Plant Design System (PDS) Piping Component Data

669

Codelists
US Practice Geometry Standards, 2-6999
6 = 'PDS-P1'
[REDE, RWELD, RPAD, BLSPC_>24"_API+/- thk varies,
BLSPO_>24"_API+/- thk varies]
7 = 'PDS-P2'
[BLSPC_>24"__API+/-_0.375"thk,
BLSPO_>24"_API+/-_0.375"thk]
8 = 'PDS-P3'
[BLSPC_>24"_MSS+/- thk varies, BLSPO_>24"_MSS+/thk varies]
11 = 'PDS-I1'
[BLSPC_>24"_API+/-_1.5"thk,
BLSPO_>24"_API+/-_1.5"thk]
12 = 'PDS-I2'
[BLPAD_>24"_MSS+/-_0.75"thk,
BLSPA_>24"_MSS+/-_0.75"thk]
13 = 'PDS-I3'
16 = 'PDS-Op1'
17 = 'PDS-Op2'
18 = 'PDS-Op3'
31 = 'ANSI-B16.1'
[Cast Iron Pipe Flanges and Flanged Fittings ||]
33 = 'ANSI-B16.3'
[Malleable Iron Threaded Fittings ||]
34 = 'ANSI-B16.4'
[Cast Iron Threaded Fittings ||]
35 = 'ANSI-B16.5'
[Pipe Flanges and Flanged Fittings ||]
39 = 'ANSI-B16.9'
[Steel Beveled End Fittings ||]
40 = 'ANSI-B16.10' [Dimensions of Ferrous Valves ||]
41 = 'ANSI-B16.11' [Forged Steel Socketwelded and Threaded Fittings ||]
42 = 'ANSI-B16.12' [Cast Iron Threaded Drainage Fittings ||]
44 = 'ANSI-B16.14' [Ferrous Pipe Plugs and Bushings]
45 = 'ANSI-B16.15' [Cast Bronze Threaded Fittings ||]
50 = 'ANSI-B16.20' [RTJ Gaskets and Grooves ||]
51 = 'ANSI-B16.21' [Flat Gaskets for Pipe Flanges ||]
52 = 'ANSI-B16.22' [Wrought Copper Solder Joint Pressure Fittings ||]
53 = 'ANSI-B16.23' [Cast Copper Solder Joint Drainage Fittings ||]
54 = 'ANSI-B16.24' [Bronze Pipe Flanges and Flanged Fittings ||]
55 = 'ANSI-B16.25' [Beveled End Preparation]
56 = 'ANSI-B16.26' [Cast Copper Alloy Fittings for Flared Copper
Tubing]
58 = 'ANSI-B16.28' [Steel Beveled End Short Radius Elbows and Returns
||]
59 = 'ANSI-B16.29' [Wrought Copper Solder Joint Drainage Fittings]
64 = 'ANSI-B16.34' [Valves Flanged and Beveled Ends ||]
66 = 'ANSI-B16.36' [Steel Orifice Flanges ||]
69 = 'ANSI-B16.39' [Malleable Iron Threaded Pipe Unions ||]
72 = 'ANSI-B16.42' [Ductile Iron Pipe Flanges and Flanged Fitting ||]
73 = 'ANSI-B16.43' [Wrought Copper Alloy Solder Joint Fittings for
Solvent
Drainage Systems]
81 = 'ANSI-B18.2.1' [Square and Hex Bolts and Screws ||]
82 = 'ANSI-B18.2.2' [Square and Hex Nuts]
100 = 'ANSI-B36.10M' [Welded and Seamless Wrought Steel Pipe ||]
109 = 'ANSI-B36.19M' [Stainless Steel Pipe ||]

670

Plant Design System (PDS) Piping Component Data

Codelists
114 = 'API-5A'
115 = 'API-5B'
119 = 'API-5L'
120 = 'API-5LE'
122 = 'API-5LP'
124 = 'API-5LS'
126 = 'API-5LU'
127 = 'API-5LX'
131 = 'API-6A'
132 = 'API-6AB'
135 = 'API-6D'
Swivels]
141 = 'API-526'
145 = 'API-590'
146 = 'API-590Z1'
147 = 'API-590Z2'
153 = 'API-593'
154 = 'API-594'
155 = 'API-595'
157 = 'API-597'
159 = 'API-599'
160 = 'API-600'
161 = 'API-601'

[Casing, Tubing and Drill Pipe]


[Casing, Tubing and Line Pipe Threads]
[Line Pipe ||]
[Polyethylene Line Pipe ||]
[Thermoplastic Line Pipe ||]
[Spiralweld Line Pipe ||]
[Ultra High Test Heat Treated Line Pipe ||]
[High Test Line Pipe]
[Wellhead Equipment]
[30,000 PSI Flanged Wellhead Equipment]
[Pipeline Valves, End Closures, Connectors and
[Flanged Steel Safety Relief Valves]
[Steel Line Blanks ||]
[Steel Line Blanks - with 0.125" CA ||]
[Steel Line Blanks - with 0.25" CA ||]
[Ductile Iron Plug Valves]
[Wafer Check Valves]
[Cast Iron Gate Valves]
[Steel Venturi Gate Valves]
[Steel Plug Valves]
[Steel Gate Valves ||]
[Metallic Gaskets for Raised Face Pipe Flanges and
Flanged Connections ||]
[Compact Steel Gate Valves]
[Class 150 Cast Flanged End Gate Valves]
[Ductile Iron Gate Valves]
[Large Diameter Carbon Steel Flanges ||]
[Compact Carbon Steel Gate Valves]
[Butterfly Valves Lug and Wafer Type]
[Cast Iron Soil Pipe and Fittings]
[Reinforced Concrete Culvert, Storm Drain and Sewer

162
163
164
165
166
169
171
172
Pipe]
173

= 'API-602'
= 'API-603'
= 'API-604'
= 'API-605'
= 'API-606'
= 'API-609'
= 'ASTM-A74'
= 'ASTM-C76'

174
176
||]
177
||]
179
181
184
186

= 'ASTM-D2464'
= 'ASTM-D2466'

[Extra Strength and Standard Strength Clay Pipe and


Perforated Clay Pipe]
[Threaded PVC Plastic Pipe Fittings Schedule 80]
[Socket-Type PVC Plastic Pipe Fittings Schedule 40

= 'ASTM-D2467'

[Socket-Type PVC Plastic Pipe Fittings Schedule 80

=
=
=
=

[Cast Iron Pipe]


[Ductile Iron and Gray Iron Fittings 3"-48" ||]
[Ductile Iron and Gray Iron Pipe]
[Ductile Iron Pipe ||]

= 'ASTM-C700'

'AWWA-C106'
'AWWA-C110'
'AWWA-C115'
'AWWA-C151'

Plant Design System (PDS) Piping Component Data

671

Codelists
190=

'AWWA-C207 Cl.B & D, ring'


[Steel slip-on flanges CL86, CL150, CL175 ||]
191= 'AWWA-C207 Cl.B & D, hub'
[Steel slip-on flanges CL86, CL150, CL175 ||]
192= 'AWWA-C207 Cl.E, hub'
[Steel slip-on flanges CL275 ||]
193 = 'AWWA-C208'
[Steel Water Pipe Fittings]
200 = 'AWWA-C500'
[Gate Valves 3"-48" for Water and Sewage Systems]
204 = 'AWWA-C504'
[Rubber Seated Butterfly Valves]
206 = 'AWWA-C506'
[Backflow Prevention Devices-Check Valves]
207 = 'AWWA-C507'
[Ball Valves]
208 = 'AWWA-C508'
[Swing Check Valves for Water Works Service 2"-24"]
220 = 'AWWA-C900'
[PVC Pipe 4"-12" for Water]
221 = 'AWWA-C901'
[Polyethylene Pipe, Tubing and Fittings 1/2"-3" for
Water]
222 = 'AWWA-C902'
[Polybutylene Pipe, Tubing and Fittings 1/2"-3" for
Water]
230 = 'AWWA-C950'
[Glass-Fiber Reinforced Pressure Pipe]
235 = 'PFI-ES-24'
[Pipe Bending Tolerances ||]
243 = 'ISA-S75.03'
[Face to Face Dimensions Globe Control Valves]
244 = 'ISA-S75.04'
[Face to Face Dimensions Flangeless Control Valves]
252 = 'MSS-SP-42'
[CL150 Valves ||]
253 = 'MSS-SP-43'
[Stainless Steel Buttwelding Fittings]
254 = 'MSS-SP-44'
[Steel Pipe Line Flanges ||]
255 = 'MSS-SP-51'
[CL150LW Cast Flanges and Flanged Fittings]
268 = 'MSS-SP-58'
[Pipe Hangers and Supports]
277 = 'MSS-SP-67'
[Butterfly Valves]
278 = 'MSS-SP-68'
[High Pressure-Offset Seat Butterfly Valves]
282 = 'MSS-SP-72'
[Ball Valves with Flanged or Beveled Ends]
285 = 'MSS-SP-75'
[Wrought Beveled End Fittings]
288 = 'MSS-SP-78'
[Cast Iron Plug Valves]
289 = 'MSS-SP-79'
[Socketwelding Reducing Inserts]
290 = 'MSS-SP-80'
[Bronze Gate, Globe, Angle & Check Valves]
291 = 'MSS-SP-81'
[Flanged, Wafer Knife Gate Valves]
293 = 'MSS-SP-83'
[Carbon Steel Socketwelded and Threaded Pipe Unions
||]
295 = 'MSS-SP-88'
[Diaphragm Valves]
297 = 'MSS-SP-95'
[Swage Nipples and Bull Plugs ||]
298 = 'NFPA-1963'
[Screw Threads and Gaskets for Fire Hose
connections]
300 = 'ASME BPE-97'
Geometry standards that follow apply to specific manufacturers.
If one of these standards is used to define a component, the
following information will be shown in brackets to the right of the
geometry standard:
o For valves:
the applicable model codes and vendor's designations
o For fittings: the applicable model codes will be shown unless
the vendor's designation is required to differentiate between
components requiring a different geometry standard to assign them
to the proper data table.

672

Plant Design System (PDS) Piping Component Data

Codelists
1000 = 'Adamson 1'
1001 = 'Adams 1'
1025 = 'Aitken 1' [BLPAD; BLSPA; TDRA; TDRB; TDRBW ||]
1026 = 'Aitken Z1' [BLPAD; BLSPA - with 0.125" CA ||]
1027 = 'Aitken Z2' [BLPAD; BLSPA - with 0.25" CA ||]
1050 = 'Allied Pipe Products 1'
1075 = 'Aldo Colombo 1'
1100 = 'Aloyco 1' [GATR-Fig_114; GATR-Fig_114DB; GATR-Fig_114EB;
GATR-Fig_124;
GATR-Fig_2214A; GLOR-Fig_2310A; GLOR-Fig_2314A; GLOR-Fig_314;
GLOR-Fig_314DB;
GLOR-Fig_314EB; GLOR-Fig_504; CKLR-Fig_554; CKLR-Fig_2554A;
CKSR-Fig_2374;
CKSR-Fig_374; TKDR-Fig_751 ||]
1101 = 'Aloyco 2' [GATR-Fig_2110; GATR-Fig_2114 ||]
1125 = 'American Darling 1' [H3W1-Fig_B-50-B ||]
1130 = 'American DI Pipe' [PIPE; L; LRB ||]
1150 = 'American Valve 1'
1175 = 'Amri 1'
1200 = 'Anaconda 1'
1225 = 'Anderson Greenwood 1'
1250 = 'Anvil 1'
1275 = 'A.O.Smith 1'
1300 = 'Apollo 1'
1325 = 'Argus 1'
1350 = 'Armstrong 1' [S51AC-Fig_K1SC; S70AC-Fig_2011; S70BC-Fig_2011 ||]
1375 = 'Asahi/American 1'

Plant Design System (PDS) Piping Component Data

673

Codelists
1400
1425
1450
1475
1500
1525
1550
1560
1575

= 'Babbitt 1'
= 'Babcock and Wilcox 1'
= 'Badger Meters 1'
= 'Bailey Co 1'
= 'Balon 1'
= 'Basic Engineering 1'
= 'Bestobel 1'
= 'Bete 1' [SSP1-Series_N ||]
= 'Bonney Forge 1' [GAT-Fig_9HLF-10; GATR-Fig_9H-10; GATR-Fig_9W-10;
GATEXB-Fig_VLL-10; GATEXB-Fig_VOLL-10; GLOR-Fig_HL-30;
GLOR-Fig_9HL-30;
GLOR-Fig_9WL-30; CKLR-Fig_9HL-40; CKLR-Fig_9HL-50;
CKLR-Fig_9HL-60;
CKLR-Fig_9WL-40; CKLR-Fig_9WL-50; CKLR-Fig_9WL-60;
CKLR-Fig_HL-40;
CKLR-Fig_9HLF-40; CKLRY-Fig_9Y-40; CKLRY-Fig_25Y-40; CAPOT; UN;
L; LRB;
SWOL; WOL; SOL; TOL; NOL; EOLLR; EOLSR; LOL ||]
1576 = 'Bonney Forge 2' [GATR-Fig_9H-10; GATR-Fig_25W-10;
GLOR-Fig_9HL-30;
GLOR-Fig_9WL-30; GLOR-Fig_25W-30; GLOY-Fig_25Y-30;
CKLR-Fig_9HL-40;
CKLR-Fig_9HL-50; CKLR-Fig_9HL-60; CKLR-Fig_9WL-40;
CKLR-Fig_9WL-50;
CKLR-Fig_9WL-60 ||]
1577 = 'Bonney Forge 3' [GATF-Fig_H-10; GATF-Fig_W-10; GATR-Fig_HL-10;
GATR-Fig_WL-10; CKLR-Fig_HL-40; CKLR-Fig_WL-40 ||]
1585 = 'Boots & Coots 1' [MN1-Spectrum_Allpha_6235 ||]
1590 = 'Bray 1'
1600 = 'Brooks Meters 1'
1625 = 'Cameron 1'
1650 = 'Carbone 1'
1675 = 'Ciba-Geigy 1'
1700 = 'Clark Reliance 1'
1725 = 'Clayton Automatic Valves 1' [CKBP-Model_D; FLO-Series_427-01 ||]
1750 = 'Clayton Mark 1'
1775 = 'Clow 1'
1800 = 'Cochrane 1'
1825 = 'Condren 1'
1850 = 'Continental Emsco 1'
1875 = 'Cooper Valve 1'
1900 = 'Crane 1' [GATF-Fig_3904U; GATR-Fig_424; GATR-Fig_431UB;
BALR-Fig_9302;
GLOF-Fig_3944U; GLOR-Fig_14 1/2P; GLOR-Fig_70; GLOY-Fig_7189;
NEE-Fig_88;
CKS-Fig_373;CKLF-Fig_3973U; CKSR-Fig_36; CKSR-Fig_137;
FOOT-Fig_394;
FOOT-Fig_395; FLWN; FSO; L; LRB ||]
1925 = 'Crosby 1'

674

Plant Design System (PDS) Piping Component Data

Codelists
1950
1975
2000
2025
2050
2075
2100
2150
2155
2175
2200
2225
2250
2275
2300
2325
2350
2375
2400
2425
2450
2475
2500
2525
2550
2575
2600
2625
2650
2660
2675
2700
||]
2715
2725
2750
2775
2800
2825
2850
2860
2875
2900
2915
2925
2950
2975
2980

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Daniel 1'
'Demco 1'
'Dezurik 1'
'Dixon 1'
'Dresser 1'
'Dover 1'
'DOW 1' [TRI-Lining_SL; TRI-Lining_PPL, TRI-Lining_KL ||]
'Duo Seal 1'
'Dur-O-Lock 1' [CPL ||]
'Durco 1'
'Elkhart 1'
'Enpro 1'
'Epsco 1'
'Everest 1'
'Fabri-Valve 1' [KNF-Fig_36 ||]
'Fairbanks 1'
'Fasani 1'
'Fetterolf 1'
'Fibercast 1'
'Fike 1'
'Fisher 1'
'Flexitallic 1'
'Flowline 1'
'FMC 1'
'Foxboro 1'
'Garlok 1'
'General 1'
'Geosource 1'
'Gestra 1'
'Gladding McBean 1' [REDC; E45; E90; M451; M452; L ||]
'Graylock 1'
'Grinnell 1' [BALR-Fig_3022; CAPOT; UNO; E45U; E90RST; TOUB; TOUR

= 'Grinnell Fire Prot 1' [DEL-Model_A-4; SSP-Mulsifyre-Projector ||]


= 'Grove 1'
= 'Gulf 1'
= 'Hammond 1'
= 'Hancock 1' [BDA-Fig_5505W ||]
= 'Haws 1' [SSEW1-Fig_8309; SSEW1-Fig 8309CRP ||]
= 'Heaton 1'
= 'Hex 1'
= 'Hindle-Hamer 1'
= 'Hitachi 1'
= 'Hoke 1'
= 'Hydril 1'
= 'Imperial Eastman 1'
= 'Ishida 1'
= 'ITT 1'

Plant Design System (PDS) Piping Component Data

675

Codelists
3000 = 'Jacoby Tarbox 1'
3025 = 'Jamesbury 1' [BALR-Style_B; BALSP-Type_530S; BAL3W-Style_AM150FD;
BAL3W-Style_DM150FD ||]
3026 = 'Jamesbury 2' [BALR-Style_A ||]
3027 = 'Jamesbury 3' [BALR-Type_2000_Brass ||]
3028 = 'Jamesbury 4' [BALF-Type_4000; BALR-Type_4000 ||]
3050 = 'Jenkins 1'
3075 = 'Jerguson 1'
3100 = 'Judd Valve 1'
3125 = 'Kamyr-Neles 1'
3150 = 'Kemp 1'
3175 = 'Kennedy 1'
3200 = 'Keystone 1'
3225 = 'Kinka Kikai 1'
3250 = 'Kitz 1'
3275 = 'KTM 1'
3300 = 'Kubota 1'
3325 = 'L & M Valve 1'
3350 = 'Ladish 1' [CAPOT; L; LRB ||]
3375 = 'Lamons 1'
3400 = 'Lukens 1'
3425 = 'Lunkenheimer 1'
3445 = 'Mac-Iron 1'
3450 = 'Magnetrol 1'
3475 = 'Malbranque 1'
3500 = 'Maloney 1'
3525 = 'Mark Controls/Centerline 1' [BFYLP-Series_A; BFYLP-Series_LT;
BYFLP-Series_504 ||]
3550 = 'Mark Controls/Flowseal 1' [BFYHP-Style_1LB ||]
3575 = 'Mark Controls/Marpac 1'
3600 = 'Mark Controls/Pacific 1' [GATSP-Fig_21555; GATSP-Fig_55509;
GATSP-Fig_55515;
GLOSP-Fig_56009; GLOSP-Fig_56015; CKSSP-Fig_58809-5-WE;
CKSSP-Fig_58815-7-WE;
CKST-Fig_160S ||]
3625 = 'Marlin 1'
3650 = 'Marwin 1'
3675 = 'Masoneilan 1'
3700 = 'Media 1' [BFYLP]
3725 = 'Milwaukee 1'
3750 = 'Mueller/Muessco Brass 1'
3775 = 'Mueller/Muessco Steam Specialty 1' [S51AC-Fig_761WE;
S51AC-Fig_862BC;
S51AC-Fig_762 ||]
3800 = 'Navco 1'
3825 = 'Nells 1'
3850 = 'Newco 1'
3860 = 'Nibco 1'
3875 = 'Nicholson 1' [S78AC-Fig_N302L ||]
3900 = 'Nippon-Benkan 1' [BW fittings above 48" ||]
3925 = 'Nupro 1'
3950 = 'OPW 1'
3975 = 'Orbit 1'
4000 = 'Oseco 1'

676

Plant Design System (PDS) Piping Component Data

Codelists
4025
4030
4050
4075
4100
4125
4150
4175
4200
||]
4225
4250
4275
4300
4325
4335
4350
4375
4400
4425

=
=
=
=
=
=
=
=
=

'Pan Korea 1'


'Parker CPI 1'
'Parks Cramer 1'
'Peabody Dore 1'
'Penberthy 1'
'Penn-AirCheck 1'
'Persta 1'
'Petrolvalves 1'
'Posi-Seal 1' [BFYHP-Model A31; BFYHP-Model A21; BFYHP-Model A11

= 'Powhatan 1' [HOS-No_18-217; HOSA-No_18-157; HRST1-No_30-333 ||]


= 'Powell 1'
= 'Pratt 1' [BFYLP-Model_PIVA & IBV-FM4; Groundhog ||]
= 'Premafu 1'
= 'Protectoseal 1'
= 'R & G Sloane' [BALF-Fig_1081; CAPOT; FS; INSR1]
= 'Resistoflex 1' [PIN-Code_R6000D1 ||]
= 'Ring-O 1'
= 'Rockwell 1' [DIA-Type_STD_Unlined ||]
= 'Rockwell/Edwards 1' [GLOA-Fig_849; GLOA-Fig_849Y; GLOYR-Fig_848;
GLOYR-Fig_848Y; GLOYR-Fig_1048; GLOYR-Fig_1048Y; CKLRY-Fig_36178;
CKLRY-Fig_36278; NEE-Fig_4152; CKST-Fig_302; CKST-Fig_302Y;
CKAST-Fig_303;
CKAST-Fig_303Y; CKAST-Fig_869; CKAST-Fig_869Y; CKYST-Fig_302;
CKYST-Fig_602Y;
BDY-Fig_1641; ||]
4426 = 'Rockwell/Edwards 2' [CKLRY-Fig_832Y; GLOY-Fig_36124;
GLOY-Fig_36128;
CKLRY-Fig_1032Y; CKAST-Fig_605Y; CKAST-Fig_607Y; BDA-Fig_1643Y ||]
4427 = 'Rockwell/Edwards 3' [GLOY-Fig_7514Y ||]
4450 = 'Rockwell/McCanna 1' [BAL3W-Type_500-3WAY ||]
4475 = 'Rockwell/Nordstorm 1' [PLUVP-Fig_4169; PLU3W-Fig_3813;
PLU3W-Fig_4812;
PLU3W-Fig_4813; PLU3W-Fig_5115; PLU3W-Fig_5119; PLU3W-Fig_5215;
PLU3W-Fig_5219; PLU4W-Fig_3823; PLU4W-Fig_4822; PLU4W-Fig_5125;
PLU4W-Fig_5129 ||]
4500 = 'R P & C 1'

Plant Design System (PDS) Piping Component Data

677

Codelists
4520 = 'Sarco 1'
4522 = 'Saunders 1'
4525 = 'Sella 1'
4550 = 'Serck Audco 1'
4575 = 'Serfilco 1'
4600 = 'Shoritsu 1'
4625 = 'Smith 1' [GATF-Fig_888; GATF-Fig_5870; GATR-Fig_800;
GATR-Fig_870;
GATR-Fig_1500; GATR-Fig_1570; GATEX-Fig_811 & 812 MPE/THD;
GATEX-Fig_876
& 877 MPE/THD; GATEXB-Fig_874 & 875 OLET/THD; GATXBA-Fig_874 & 875
OLET/SW;
GATXBB-Fig_874 & 875 OLET/THD; GLOR-Fig_G80; GLOR-Fig_G87;
GLOR-Fig_G150;
GLOR-Fig_G157; CKLR-Fig_B80; CKLR-Fig_C80; CKLR-Fig_C150;
CKLR-Fig_SB80;
CKLR-Fig_SC80 ||]
4626 = 'Smith 2' [GATEX-Fig_813 & 814 MPE/SW; GATEX-Fig_878 & 879 MPE/SW
||]
4650 = 'Spraying Systems 1'
4675 = 'Spirax Sarco 1'
4700 = 'Stanco 1'
4725 = 'Standard Fittings 1' [CAPOT; SWGC; SWGE ||]
4750 = 'Stang Hydronics 1' [M1-Fig BB0309-21 w/shapertip nozzle; ME1-Fig
BB3561 ||]
4751 = 'Stang Hydronics 2' [M1-Fig_BB0309-21 w/fog nozzle; ME1-Fig B22999
||]
4752 = 'Stang Hydronics 3' [ME1-Fig_BB3561 composite, w/monitor nozzle
||]
4753 = 'Stang Hydronics 4' [ME1-Fig_BB3377 composite, w/monitor nozzle ||]
4775 = 'Stockham 1'
4800 = 'Strahman 1'
4825 = 'Swagelok 1'
4850 = 'Tapco 1'
4875 = 'Taylor 1'
4900 = 'Taylor Forge 1'
4901 = 'Taylor Forge 2, Rev 1957' [L; S-STD WT ||]
4925 = 'Teledyne Farris 1'
4950 = 'Texas Bolt 1'
4975 = 'Thevignot 1'
5000 = 'Titeflex 1'
5025 = 'TK 1'
5050 = 'TKM 1' [GAT-Fig_100 ||]
5060 = 'Top Line 1'
5075 = 'Triangle 1'
5085 = 'Tri-Clover 1'
5100 = 'Truflo 1'
5125 = 'TRW/Mission 1' [||]
5150 = 'Tubeturn 1' [FWN; FEWN; FOWNA; FOWNB; CAPBV; E453D; E90LT; E903D;
L; SAD ||]
5175 = 'Tufline 1'
5200 = 'Tyler 1' [CPL; REDC; E45LT; E90LT; L ||]

678

Plant Design System (PDS) Piping Component Data

Codelists
5225
5250
5275
5300
5325
5350
5375

= 'Valvotecnic 1'
= 'Vanessa 1'
= 'Velan 1' [S3AC-Fig_N675 ||]
= 'Victaulic 1'
= 'Viking 1'
= 'Vitas 1'
= 'Vogt 1' [GATR-Series_15373; GLOR-Series_15141; CKLR-Series_15701;
NEE-Series_22461; NEE-Series_SW22461; CAPOT; UN; E90U; E90ST; L ||]
5400 = 'Wada 1'
5425 = 'Wallworth 1'
5450 = 'Watts Regulator 1'
5475 = 'Weco 1'
5500 = 'WFI 1'
5525 = 'Winston 1' [S49AC-T-Strainer Type-59 W/flg'd cover;
S53AC-Basket-StrainerFig 51-WIP W/CL150 flg'd cover & 3/4" SWE drain||]
5535 = 'Wirt & Knox 1'
5550 = 'WKM 1'
5575 = 'Worcester 1'
5600 = 'Yarway 1' [CKAR-Fig_5301; CKAR-Fig_5302; BDA-Fig_6909-C;
BDY-Fig_6911-C;
TKDR-Fig_8106 ||]
5625 = 'Yoneki 1'
5650 = 'Zurn 1'
o European practices 1 (DIN)
General
7000 =
7001 =
7002 =

Specifications
'DIN 2401-1 Pressure, nominal'
'DIN 2401-2 Pressure, nominal'
'DIN 2402 Diameter,nominal'

Pipes
7010
7011
7012
7013
7014
7015
7016
7017
7018
7019
7020
7025
7026
7030
7031
7040
7041

'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

2448'
2458'
2440'
2441'
2442'
2445'
2460'
2462'
2463'
2391'
2393'
2848'
2873'
2462'
2463'
8062'
8077'

7000-11999

;Steel pipes, seamless


;Steel pipes, welded
;Threaded pipes, medium weight
;Threaded pipes, heavy weight
;Threaded pipes, spec. qualty
;Seamless steel pipes,dyn. load
;Steel pipes for water
;Seamless ferritic steel pipes
;Seamless austenitic steel pipes
;Seamless precision steel tubes
;Welded precision steel tubes
;Flanged lined pipes
;Flanged lined enamelled pipes
;Seamless stainless steel tubes
;Welded austenitic steel pipes and tubes
;Pipes of unplasticized polyvinyl chlor.
;Polypropylen (PP) pipes

Plant Design System (PDS) Piping Component Data

679

Codelists
Flanges
7100 =
7101 =
7102 =
7103 =
7104 =
7105 =
7106 =
7107 =
7108 =
7109 =
7110 =
7111 =
7112 =
7113 =
7114 =
7115 =
7116 =
7117 =
7118 =
7119 =
7120 =
7121 =
7122 =
7123 =
7124 =
7125 =
7126 =
7127 =
7128 =
7129 =
7130 =
7131 =
7132 =
7133 =
7134 =
7135 =
7136 =
7137 =
7138 =
7139 =
7140 =
7141 =
7142 =
7143 =
7144 =
7145 =
7146 =
7147 =
7148 =
7149 =
7150 =
7160 =

680

'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN

2530'
2531'
2532'
2533'
2534'
2535'
2543'
2544'
2545'
2546'
2547'
2548'
2549'
2550'
2551'
2558'
2561'
2565'
2566'
2567'
2568'
2569'
2630'
2631'
2632'
2633'
2634'
2635'
2636'
2637'
2638'
2628'
2629'
2627'
2673'
2667'
2668'
2669'
2573'
2576'
2641'
2642'
2652'
2653'
2655'
2656'
2501'
2512'
2512'
2513'
2514'
2527'

;Cast iron flanges, PN 2,5


;Cast iron flanges, PN 6
;Cast iron flanges, PN 10
;Cast iron flanges, PN 16
;Cast iron flanges, PN 25
;Cast iron flanges, PN 40
;Cast steel flanges, PN 16
;Cast steel flanges, PN 25
;Cast steel flanges, PN 40
;Cast steel flanges, PN 64
;Cast steel flanges, PN 100
;Cast steel flanges, PN 160
;Cast steel flanges, PN 250
;Cast steel flanges, PN 320
;Cast steel flanges, PN 400
;Plain face oval screwed flange PN 6
;Oval screwed flange w/ socket PN 10,16
;Screwed flange PN 6 rund
;Screwed flange PN 10,16
;Screwed flange PN 25,40
;Screwed flange PN 64
;Screwed flange PN 100
;Welding neck flange PN 1
;Welding neck flange PN 6
;Welding neck flange PN 10
;Welding neck flange PN 16
;Welding neck flange PN 25
;Welding neck flange PN 40
;Welding neck flange PN 64
;Welding neck flange PN 100
;Welding neck flange PN 160
;Welding neck flange PN 250
;Welding neck flange PN 320
;Welding neck flange PN 400
;Loose flange w/ wldg neck PN 10
;Loose flange w/ wldg neck PN 160
;Loose flange w/ wldg neck PN 250
;Loose flange w/ wldg neck PN 320
;Flange, soldering or wldg PN 6
;Flange, soldering or wldg PN 10
;Flange, lapped, plain collar PN 6
;Slip-on flange, upturned wldg PN 10
;Flange, lapped, plain collar PN 6
;Flange, lapped, plain collar PN 10
;Flange, lapped, plain collar PN 25
;Flange, lapped, plain collar PN 40
;Flanges, Dimensions
;Flanges, tongue & groove
;Rings
;Flanges, projection & recess
;Projection w/ groove & recess
;Flange, blind PN 6,10,16,25,40,64,100

Plant Design System (PDS) Piping Component Data

Codelists
7161 = 'DIN 2848'
7162 = 'DIN 2873'
Elbows
7200 =
7201 =
7202 =
7203 =
7204 =
7205 =
7206 =
7210 =
7211 =
7212 =
7213 =
7214 =
7215 =
7216 =
7217 =
7218 =
7219 =
7230 =
7231 =
7240 =
7241 =
7242 =

'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN

;Reducing flanges, lined


;Reducing and blind flanges, enamelled

2605' ;Tube bends f. butt wldg


2606' ;Tube bends, steel 5d
2916' ;Bending radii, seaml.& wld pipes
2983' ;Threaded steel pipe fittings, bends
2987' ;Threaded steel pipe fittings, elbows
2987' ;Threaded steel pipe fittings, elbows, reduced
2950' ;Malleable cast iron fittings, elbows
2605-1'
;Elbows, bend radius 1d, standard 12.85
2605-1'
;Elbows, bend radius 1.5d, standard 12.85
2605-1'
;Elbows, bend radius 2.5d, standard 12.85
2605-1'
;Elbows, bend radius 5d, standard 12.85
2605-1'
;Elbows, bend radius 10d, standard 12.85
2605-2'
;Elbows, bend radius 1d, standard 12.85
2605-2'
;Elbows, bend radius 1.5d, standard 12.85
2605-2'
;Elbows, bend radius 2.5d, standard 12.85
2605-2'
;Elbows, bend radius 5d, standard 12.85
2605-2'
;Elbows, bend radius 10d, standard 12.85
2848' ;Flanged lined steel fittings, Bends
2873' ;Flanged steel fittings enamelled, Bends
16962' ;Polypropylen (PP) components, Pipe bends B1,B2
16962' ;Polypropylen (PP) components,Elb. W1,W2,part 6
16962' ;Polypropylen (PP) components,Elb.W3,W4,part 10

Reducers
7300 = 'DIN
7301 = 'DIN
7302 = 'DIN
7303 = 'DIN
7304 = 'DIN
7310 = 'DIN
7311 = 'DIN
7320 = 'DIN
7321 = 'DIN
7322 = 'DIN
7323 = 'DIN

2616'
2990'
2988'
2950'
2950'
2848'
2873'
16962'
16962'
16962'
16962'

;Steel fittings, reducers


;Threaded steel pipe fittings, Bushings
;Threaded steel pipe fittings, Reducing sockets
;Malleable cast iron fittings, Reducing sockets
; - " - , male and female connections, Bushings
;Flanged lined steel fittings, Reducers
;Flanged steel fittings enamelled, Reducers
;Polypropylen (PP) components, Red. R1, part 9
;Polypropylen (PP) components, Red. NRGI, part 9
;Polypropylen (PP) components, Red. R2, part 10
;Polypropylen (PP) components, Red. R3, part 11

Branches
7400 = 'DIN
7401 = 'DIN
7402 = 'DIN
7403 = 'DIN
7404 = 'DIN
7405 = 'DIN
7406 = 'DIN
7410 = 'DIN
7411 = 'DIN
7420 = 'DIN
7421 = 'DIN
7422 = 'DIN
7423 = 'DIN

2615'
2618'
2618'
2619'
2987'
2987'
2950'
2848'
2873'
16962'
16962'
16962'
16962'

;Butt wldg steel fittings;T


;Welding saddles, short
;Welding saddles, long
;Bends for welding
;Threaded steel fittings;cross;T
;Threaded steel fittings;cross;T;redcd
;Malleable cast iron fittings, Tees, Crosses
;Flanged lined steel fittings, T
;Flanged steel fittings enamelled, T
;Polypropylen (PP) components, Tee, T1,T5 part 2
;Polypropylen (PP) components, Tee, T2, part 7
;Polypropylen (PP) components, Tee, T2G, part 7
;Polypropylen (PP) components, Tee, T3, part 10

Plant Design System (PDS) Piping Component Data

681

Codelists
Caps
7500
7501
7502
7510
7511

=
=
=
=
=

Other
7600
7601
7602
7603
7604
7605
7606
7610

fittings
= 'DIN 2981'
= 'DIN 2982'
= 'DIN 2982'
= 'DIN 2986'
= 'DIN 2990'
= 'DIN 2991'
= 'DIN 2993'
= 'DIN 2950'

'DIN
'DIN
'DIN
'DIN
'DIN

2617'
2991'
2950'
16962'
16962'

;Butt wldg steel fittings, Caps


;Threaded steel fittings, Caps
;Malleable cast iron fittings, Caps
;Polypropylen (PP) components, Cap K1, part 8
;Polypropylen (PP) components, Cap K2, part 10

;Threaded steel fittings with long screw thread


;Threaded steel fittings, Parallel Nipples
;Threaded steel fittings, Taper Nipples
;Threaded steel fittings, Sockets
;Threaded steel fittings, Hexagon Nipples
;Threaded steel fittings, Plain plugs
;Threaded steel fittings, Pipe unions
;Malleable cast iron fittings, Sockets, Unions,
;Nipples, Plugs etc.
7620 = 'DIN 16962' ;Polypropylen (PP) components, Soc. M1,MGI, p. 8
7630 = 'DIN 2848' ;Flanged lined steel fittings, spacers
7631 = 'DIN 2873' ;Flanged lined steel fittings enamelled, spacers

Bolts and Nuts


8000 = 'DIN 934'
8001 = 'DIN 931'
Gaskets
8100 =
8101 =
8102 =
8103 =
8104 =
8105 =
8106 =
8107 =

'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN
'DIN

2690'
2691'
2692'
2693'
2695'
2696'
2697'
2698'

Valves
9000 =
9010 =
9020 =
9030 =
9040 =
9050 =

'Non
'DIN
'DIN
'DIN
'DIN
'DIN

conform DIN 3202'


3202-F'
; Teil 1
3202-S'
; Teil 2
3202-K'
; Teil 3
3202-M'
; Teil 4
3202-F'
; Teil 5

;Gasket for plain face C


;Gasket for tongue & groove
;Gasket for recessed faces
;Rings for grooved faces
;Diaphragm
;Lenticular gaskets
;Grooved O- rings
;Corrugated steel sheet

Dummy standard
9999 = 'Dummy DIN Std' ; Used for engineered items and instruments
British Standards geometry standards 12000-16999

682

Plant Design System (PDS) Piping Component Data

Codelists
sub ranges (provisional) :12000-12099 pipes
12100-12199 flanges
12200-12599 fittings
12600-12999 valves
13000-13199 bolts
13200-13499 gaskets
PIPES
12000
12001
12002
12003
12004
12010
12015

=
=
=
=
=
=
=

'BS3600
'BS3600
'BS3600
'BS3600
'BS3600
'BS1387
'BS1600

table 1 carbon and low alloy steel tubes'


table 2 austenitic stainless steel tubes'
table 3 high alloy ferritic steel tubes'
table 4 cs tubes for compression fitting - tbi'
table 5 ss tubes for compression fitting - tbi'
tables 3,4 and 5 light,medium and heavy'
part 2 steel pipe for petroleum industry'

FLANGES
12100 = 'BS4504 p1 steel flanges for pipe,valves and fittings'
12101 = 'BS4504 p1 iron flanges for pipe,valves and fittings - tbi'
12110 = 'BS1560 p2 steel pipe flanges Metric dimensions'
FITTINGS
12200 = 'BS1740
12210 = 'BS1965
12220 = 'BS3799
12221 = 'BS3799
12230 = 'BS1640
VALVES
12600 =
12620 =
12625 =
12630 =
12635 =
12640 =
12645 =
12646 =
12650 =
12651 =
12655 =
12656 =
12660 =
12661 =
12665 =
12666 =
12670 =
12671 =

part 1 screwed wrought steel pipe fittings '


part 1 butt welding pipe fittings - CS'
steel pipe fittings screwed and socket welding (mm)'
steel pipe fittings screwed and socket welding (in)'
part 3/4 steel butt-welding pipe fittings '

'BS2080 flanged
'BS5150'
'BS5151'
'BS5152'
'BS5153'
'BS5154'
'BS5155'
'BS5155 and app
'BS5156'
'BS5156 and app
'BS5157'
'BS5157 and app
'BS5158'
'BS5158 and app
'BS5159'
'BS5159 and app
'BS5160'
'BS5160 and app

and butt-welded steel valves'

A'
A'
A'
A'
A'
A'

gaskets
13001 = 'BS4865:part 1 - non-metallic for BS4504 flanges'
13002 = 'BS4865:part 2 - spiral wound for BS4504 flanges'
13010 = 'BS3381 - spiral wound for BS1560 flanges'

Plant Design System (PDS) Piping Component Data

683

Codelists
bolting
13200 = 'BS4882 metric series bolting'
13210 = 'BS4882 inch series bolting'
dummy
13999 = 'dummy BS code'

CL576, Table Suffix/End Standard - Green (999)


Codelist numbers have been reserved as follows:
o
o
o
o
o
o
o

US practices
European practices 1 (DIN)
European practices 2 (British)
European practices 3 (Finnish, French, etc.
International practices 1 (JIS)
International practices 2 (Australian, etc.)
Company practices

2-99
100-199
200-299
300-399
400-499
500-599
900-999

1 = [Blank]
US Practice Table Suffixes, 2-99
5 = 'Default'
[See below for definition]
6 = 'PDS-1'
[See specific table for details]
7 = 'PDS-2'
[See specific table for details]
8 = 'PDS-3'
[See specific table for details]
10 = 'ID Duct'
[Nominal diameter based on inside diameter]
12 = 'ANSI-B16.12'
[Cast iron drainage fittings]
15 = 'ANSI-B16.15'
[Cast bronze fittings]
22 = 'ANSI-B16.22'
[Copper solder joint pressure fittings]
23 = 'ANSI-B16.23'
[Copper solder joint drainage fittings]
24 = 'ANSI-B16.24'
[Bronze flanges]
29 = 'ANSI-B16.36'
[Orifice flanges]
30 = 'ANSI-B16.42'
[Ductile iron flanges and fittings]
33 = 'ANSI-B1.20.3' [Dryseal pipe threads]
37 = 'ANSI-B1.20.7' [Hose coupling screw threads]
40 = 'ASME BPE-97 (PE)'
41 = 'ASME BPE-97 (MCE)'
45 = 'ASTM-A74'
[Cast iron S-XH soil pipe and fittings]
46 = 'ASTM-C76'
[Reinforced Concrete Culvert, Storm Drain and Sewer
Pipe]
47 = 'ASTM-C700'
[Extra Strength and Standard Strength Clay Pipe and
Perforated
Clay Pipe]
49 = 'AWWA-C110'
[Iron fittings]
50 = 'AWWA-C115'
[Iron pipe and fittings]
55 = 'AWWA-C151'
[Ductile iron pipe]
60 = 'AWWA-C207 Cl.B & D, ring'
[Steel slip-on flanges CL86, CL150, CL175]
61 = 'AWWA-C207 Cl.B & D, hub'
[Steel slip-on flanges CL86, CL150, CL175]
62 = 'AWWA-C207 Cl.E, hub'
[Steel slip-on flanges CL275]

684

Plant Design System (PDS) Piping Component Data

Codelists
70 = 'API-5LE'
75 = 'API-6A'
79 = 'API-605-B'
flange and
80
81
85
86
87
88
90
91
92
93
94
95
96
97
98
99

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Polyethylene fittings]
[Wellhead flanges and fittings]
[API-605 blind flanges. These are based on API-605

bolt diameters and MSS-SP44 flange thicknesses]


'MSS-SP-44-NB' [MSS non-blind flanges]
'MSS-SP-44-B'
[MSS blind flanges]
'Crosby'
'Consolidated'
'Lonergan'
'Top Line'
'Tube-Turn'
'Dow'
'Aloyco'
'Yarway'
'Teledyne Farris 1'
'R & G Sloane'
'American DI Pipe'
'Gladding McBean' [Vitrified clay S-XS pipe and fittings]
'Taylor Forge'
'Vendor 4'

CL No. 5 is used to define the "Default for end type", which


represents the basis on which most US-practice generic piping tables
for dimensional parameters will bedefined. The system will default
to table suffix "5" when dimensions from a male termination type
table are required in defining the component but the component ends
are other than male termination. The basis for this table suffix
will be as follows:
End Termination Type
Basis for Table Values
Flat-face flanged.................ANSI-B16.1 or B16.5
Raised-face flanged...............ANSI-B16.1, B16.5, API-605 or
MSS-SP-42,
in this order of precedence
RTJ-face flanged..................ANSI-B16.5
Tongue/male-face flanged..........ANSI-B16.5
Groove/female-face flanged........ANSI-B16.5
Flat-face lap-flanged.............ANSI-B16.5 with stub end thickness
ignored.
Raised-face lap-flanged...........ANSI-B16.5 with stub end thickness
ignored.
RTJ-face lap-flanged..............ANSI-B16.5 with stub end thickness
ignored.
Tongue/male-face lap-flanged......ANSI-B16.5 with stub end thickness
ignored.
Groove/female-face lap-flanged....ANSI-B16.5 with stub end thickness
ignored.

Plant Design System (PDS) Piping Component Data

685

Codelists
All thru-bolted...................For sizes and ratings for which API-590
applies,
the value of parameter "P" shall be
taken from
API-590. For sizes and ratings for
which API-590
does not apply, the bolt circle diameter
from
ANSI-B16.1, B16.5, API-605 or
MSS-SP-42, in that
order of precendence, less one bolt
diameter less
1/8 inch will be used for parameter "P".
Male RTJ-face thru-bolted with cap screws........................None
Flat-face thru-bolted with cap screws........................None
Raised-face thru-bolted with cap screws........................None
RTJ-face thru-bolted with cap screws........................None
Flat-full-face thru-bolted........DOW
Male..............................ANSI-B36.10M, ANSI-B36-19M, API-5L,
API-5LE,
API-5LP, API-5LS or API-5LU
PVC & CPVC socket.................API-5LP, ASTM-D2466 or ASTM-D2467
Socketwelded......................For pressure ratings XXXX#s, per basis
defined
in the applicable generic tables;
for pressure ratings CLXXXXs and
OTXXXXs, per
ANSI-B16.11 and ANSI-B16.5.
Female threaded
thread engagement per Table 2.4 of
2630-33
..................................Forged steel.For pressure ratings
XXXX#s, per basis
defined in the applicable generic
tables; for
pressure ratings CLXXXXs and OTXXXXs,
per ANSI-B16.11
and ANSI-B16.5. In all cases, thread
engagement
will be per Table 2.4 of 2630-33
descriptions in the applicable generic
tables.
In all cases, thread engagement will be
per
Table 2.4 of 2630-33
Female grooved....................Victaulic catalog G100E
Female quick connect..............
Female ferrule....................
Female hose.......................
Mechanical joint bell.............AWWA-C110
Gasket............................Not applicable
Bolt..............................Not applicable
Nut...............................Not applicable
User defined......................None

686

Plant Design System (PDS) Piping Component Data

Codelists
o European practices 1 (DIN)

100-199

Codelist numbers used for DIN European practice


Generic dimension data select flag access starts here
105 = 'Gen blt & fem end prep dim'
111
112
113
114
115
116
117
118
119
125
126
129
130
131
132
133
134
140
141
142
143
144
150
160
170
171
179

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Blt dim for cast steel flanges'


'Blt dim for cast iron flanges'
'Blt dim for oval screwed flanges'
'Blt dim for screwed flanges'
'Blt dim for sold & weld flanges'
'Blt dim for lap flanges'
'Blt dim lap flanges w/ plain collars'
'Blt dim for loose flanges w/ weld neck'
'Blt dim for loose flanges in enamelled componnents'
'OD acc to DIN 2631 Reihe 1'
'OD acc to DIN 2631 Reihe 2'
'OD for plastic pipes'
'OD acc to DIN 2445-1 PN 100'
'OD acc to DIN 2445-1 PN 160'
'OD acc to DIN 2445-1 PN 250'
'OD acc to DIN 2445-1 PN 320'
'OD acc to DIN 2445-1 PN 400'
'OD acc to DIN 2445-2 PN 64-100'
'OD acc to DIN 2445-2 PN 160'
'OD acc to DIN 2445-2 PN 250'
'OD acc to DIN 2445-2 PN 320'
'OD acc to DIN 2445-2 PN 400'
'OD acc to DIN 2391'
'OD acc to DIN 2393'
'OD acc to DIN 2440'
'OD acc to DIN 2441'
'OD for threaded components'

British Standards
205 = 'default metric'
206 = 'default converted imperial'
210 = 'plate flanges BS4504'

Plant Design System (PDS) Piping Component Data

687

Codelists

CL577, Table Suffix/End Standard - Red (999)


o
o
o
o
o
o
o

Codelist numbers have been reserved as follows:


US practices
2-99
European practices 1 (DIN)
100-199
European practices 2 (British)
200-299
European practices 3 (Finnish, French, etc.
300-399
International practices 1 (JIS)
400-499
International practices 2 (Australian, etc.)
500-599
Company practices
900-999
1 = [Blank]

US Practice Table Suffixes, 2-99


5 = 'Default'
[See below for definition]
6 = 'PDS-1'
[See specific table for details]
7 = 'PDS-2'
[See specific table for details]
8 = 'PDS-3'
[See specific table for details]
10 = 'ID Duct'
[Nominal diameter based on inside diameter]
12 = 'ANSI-B16.12'
[Cast iron drainage fittings]
15 = 'ANSI-B16.15'
[Cast bronze fittings]
22 = 'ANSI-B16.22'
[Copper solder joint pressure fittings]
23 = 'ANSI-B16.23'
[Copper solder joint drainage fittings]
24 = 'ANSI-B16.24'
[Bronze flanges]
29 = 'ANSI-B16.36'
[Orifice flanges]
30 = 'ANSI-B16.42'
[Ductile iron flanges and fittings]
33 = 'ANSI-B1.20.3' [Dryseal pipe threads]
37 = 'ANSI-B1.20.7' [Hose coupling screw threads]
40 = 'ASME BPE-97 (PE)'
41 = 'ASME BPE-97 (MCE)'
45 = 'ASTM-A74'
[Cast iron S-XH soil pipe and fittings]
46 = 'ASTM-C76'
[Reinforced Concrete Culvert, Storm Drain and Sewer
Pipe]
47 = 'ASTM-C700'
[Extra Strength and Standard Strength Clay Pipe and
Perforated
Clay Pipe]
49 = 'AWWA-C110'
[Iron fittings]
50 = 'AWWA-C115'
[Iron pipe and fittings]
55 = 'AWWA-C151'
[Ductile iron pipe]
60 = 'AWWA-C207 Cl.B & D, ring'
[Steel slip-on flanges CL86, CL150, CL175]
61 = 'AWWA-C207 Cl.B & D, hub'
[Steel slip-on flanges CL86, CL150, CL175]
62 = 'AWWA-C207 Cl.E, hub'
[Steel slip-on flanges CL275]

688

Plant Design System (PDS) Piping Component Data

Codelists
70 = 'API-5LE'
75 = 'API-6A'
79 = 'API-605-B'
flange and
80
81
85
86
87
90
91
92
93
94
95
96
97
98
99

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

[Polyethylene fittings]
[Wellhead flanges and fittings]
[API-605 blind flanges. These are based on API-605

bolt diameters and MSS-SP44 flange thicknesses]


'MSS-SP-44-NB' [MSS non-blind flanges]
'MSS-SP-44-B'
[MSS blind flanges]
'Crosby'
'Consolidated'
'Lonergan'
'Tube-Turn'
'Dow'
'Aloyco'
'Yarway'
'Teledyne Farris 1'
'R & G Sloane'
'American DI Pipe'
'Gladding McBean' [Vitrified clay S-XS pipe and fittings]
'Taylor Forge'
'Vendor 4'

CL No. 5 is used to define the "Default for end type", which


represents the basis on which most US-practice generic piping tables
for dimensional parameters will bedefined. The system will default
to table suffix "5" when dimensions from a male termination type
table are required in defining the component but the component ends
are other than male termination. The basis for this table suffix
will be as follows:
End Termination Type
Basis for Table Values
Flat-face flanged.................ANSI-B16.1 or B16.5
Raised-face flanged...............ANSI-B16.1, B16.5, API-605 or
MSS-SP-42,
in this order of precedence
RTJ-face flanged..................ANSI-B16.5
Tongue/male-face flanged..........ANSI-B16.5
Groove/female-face flanged........ANSI-B16.5
Flat-face lap-flanged.............ANSI-B16.5 with stub end thickness
ignored.
Raised-face lap-flanged...........ANSI-B16.5 with stub end thickness
ignored.
RTJ-face lap-flanged..............ANSI-B16.5 with stub end thickness
ignored.
Tongue/male-face lap-flanged......ANSI-B16.5 with stub end thickness
ignored.
Groove/female-face lap-flanged....ANSI-B16.5 with stub end thickness
ignored.

Plant Design System (PDS) Piping Component Data

689

Codelists
All thru-bolted...................For sizes and ratings for which API-590
applies,
the value of parameter "P" shall be
taken from
API-590. For sizes and ratings for
which API-590
does not apply, the bolt circle diameter
from
ANSI-B16.1, B16.5, API-605 or
MSS-SP-42, in that
order of precendence, less one bolt
diameter less
1/8 inch will be used for parameter "P".
Male RTJ-face thru-bolted with
cap screws........................None
Flat-face thru-bolted with
cap screws........................None
Raised-face thru-bolted with
cap screws........................None
RTJ-face thru-bolted with
cap screws........................None
Flat-full-face thru-bolted........DOW
Male..............................ANSI-B36.10M, ANSI-B36-19M, API-5L,
API-5LE,
API-5LP, API-5LS or API-5LU
PVC & CPVC socket.................API-5LP, ASTM-D2466 or ASTM-D2467
Socketwelded......................For pressure ratings XXXX#s, per basis
defined
in the applicable generic tables;
for pressure ratings CLXXXXs and
OTXXXXs, per
ANSI-B16.11 and ANSI-B16.5.
Female threaded
thread engagement per Table 2.4 of
2630-33
..................................Forged steel.For pressure ratings
XXXX#s, per basis
defined in the applicable generic
tables; for
pressure ratings CLXXXXs and OTXXXXs,
per ANSI-B16.11
and ANSI-B16.5. In all cases, thread
engagement
will be per Table 2.4 of 2630-33
descriptions in the applicable generic
tables.
In all cases, thread engagement will be
per
Table 2.4 of 2630-33
Female grooved....................Victaulic catalog G100E
Female quick connect..............
Female ferrule....................
Female hose.......................
Mechanical joint bell.............AWWA-C110

690

Plant Design System (PDS) Piping Component Data

Codelists
Gasket............................Not applicable
Bolt..............................Not applicable
Nut...............................Not applicable
User defined......................None
o European practices 1 (DIN)

100-199

Codelist numbers used for DIN European practice


Generic dimension data select flag access starts here
105
111
112
113
114
115
116
117
118
119
125
126
129
130
131
132
133
134
140
141
142
143
144
150
160
170
171
179
181
182
183
184
185
191
192
193
194
195

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Gen blt & fem end prep dim'


'Blt dim for cast steel flanges'
'Blt dim for cast iron flanges'
'Blt dim for oval screwed flanges'
'Blt dim for screwed flanges'
'Blt dim for sold & weld flanges'
'Blt dim for lap flanges'
'Blt dim lap flanges w/ plain collars'
'Blt dim for loose flanges w/ weld neck'
'Blt dim for loose flanges in enamelled componnents'
'OD acc to DIN 2631 Reihe 1'
'OD acc to DIN 2631 Reihe 2'
'OD for plastic pipes'
'OD acc to DIN 2445-1 PN 100'
'OD acc to DIN 2445-1 PN 160'
'OD acc to DIN 2445-1 PN 250'
'OD acc to DIN 2445-1 PN 320'
'OD acc to DIN 2445-1 PN 400'
'OD acc to DIN 2445-2 PN 64-100'
'OD acc to DIN 2445-2 PN 160'
'OD acc to DIN 2445-2 PN 250'
'OD acc to DIN 2445-2 PN 320'
'OD acc to DIN 2445-2 PN 400'
'OD acc to DIN 2391'
'OD acc to DIN 2393'
'OD acc to DIN 2440'
'OD acc to DIN 2441'
'OD for threaded components'
'Wallthickness Reihe 1'
'Wallthickness Reihe 2'
'Wallthickness Reihe 3'
'Wallthickness Reihe 4'
'Wallthickness Reihe 5'
'Wallthickness selection 1'
'Wallthickness selection 2'
'Wallthickness selection 3'
'Wallthickness selection 4'
'Wallthickness selection 5'

British Standards
205 = 'default metric'
206 = 'default converted imperial'

Plant Design System (PDS) Piping Component Data

691

Codelists
210 = 'plate flanges BS4504'

CL578, Weight Code (399)


Codelist numbers 2-99 have been reserved for values that
apply to US practices. Codelist numbers 100-399 have been reserved
for values that apply to practices in other countries.
1 = [Blank]
US Practice Weight Codes, 2-99
9
10
16
22
28
30
34
40
46
47
48
52
58
64
70
76

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'35 pcf'
'57 pcf'
'88 pcf'
'97 pcf'
'111 pcf'
'150 pcf'
'165 pcf'
'260 pcf'
'450 pcf'
'450 pcf'
'450 pcf'
'490 pcf'
'490 pcf'
'525 pcf'
'555 pcf'
'570 pcf'

[Vitrified clay]
[Polypropylene]
[PVC]
[CPVC]
[FRP, Kynar]
[Reinforced concrete pipe]
[Aluminum]
[Titanium]
[Iron]
[Standard thk cement linin, ductile iron]
[Double thk cement lining ductile iron]
[Carbon steel, low Cr alloy steel, stainless steel]
[Cement lined carbon steel]
[Brass, Inconel]
[Bronze, copper, Monel, nickel]
[Hastelloy]

European Practice Weight Codes, 101-199


101
111
112
113
114
115

692

=
=
=
=
=
=

[Blank]
'Weight
'Weight
'Weight
'Weight
'Weight

selection
selection
selection
selection
selection

flag
flag
flag
flag
flag

1'
2'
3'
4'
5'

Plant Design System (PDS) Piping Component Data

Codelists
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'1'
'2'
'3'
'4'
'5'
'6'
'7'
'8'
'9'
'10'
'11'
'12'
'13'
'14'
'15'
'16'
'17'
'18'
'19'
'-'
'21'
'-'
'-'
'-'
'-'
'-'
'-'
'-'
'-'
'-'
'31'
'32'
'33'
'34'
'-'
'36'
'-'
'-'
'-'

[Acc. to DIN 3202-F1/K1/V1]


[Acc. to DIN 3202-F2/S2/K2/M2/V2]
[Acc. to DIN 3202-F3/S3/K3/M3]
[Acc. to DIN 3202-F4/K4/M4]
[Acc. to DIN 3202-F5/S5/K5/M5]
[Acc. to DIN 3202-F6/M6]
[Acc. to DIN 3202-F7/S7]
[Acc. to DIN 3202-F8/S8/M8]
[Acc. to DIN 3202-F9/S9/M9]
[Acc. to DIN 3202-S10/M10]
[Acc. to DIN 3202-F11/M11]
[Acc. to DIN 3202-S12]
[Acc. to DIN 3202-S13]
[Acc. to DIN 3202-S14/M14]
[Acc. to DIN 3202-F15/M15]
[Acc. to DIN 3202-F16]
[Acc. to DIN 3202-F17]
[Acc. to DIN 3202-F18]
[Acc. to DIN 3202-F19]
[Not existent under DIN 3202]
[Acc. to DIN 3202-V21]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Acc. to DIN 3202-S31]
[Acc. to DIN 3202-F32/M32]
[Acc. to DIN 3202-F33/M33]
[Acc. to DIN 3202-F34]
[Not existent under DIN 3202]
[Acc. to DIN 3202-M36]
[Not existent under DIN 3202]
[Not existent under DIN 3202]
[Not existent under DIN 3202]

British Standards numbers (200-299)


units kg per cubic metre
201 = [Blank]

Plant Design System (PDS) Piping Component Data

693

Codelists
209
210
216
222
228
230
234
240
246
247
248
252
253
254
258
264
270
276

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'561 km3'
'913 km3'
'1410 km3'
'1554 km3'
'1778 km3'
'2403 km3'
'2643 km3'
'4165 km3'
'7208 km3'
'7208 km3'
'7208 km3'
'7849 km3'
'7849 km3'
'7849 km3'
'7849 km3'
'8410 km3'
'8890 km3'
'9130 km3'

[polypropylene]
[pvc]
[cpvc]
[FRP, Kynar]
[Aluminium]
[Titanium]
[Iron]
[CS]
[low alloy st]
[SS]
[8mm thk cement lined CS]
[Brass, Inconel]
[Bronze, copper, Monel, Nickel]
[Hastelloy]

CL990, Types of Piping Commodity Data Forms


1
2
3
4
5
21
41
42
61
62
63

=
=
=
=
=
=
=
=
=
=
=

'General Fittings'
'Pipe Bends
'
'Orifice Flanges '
'Branch Nipples '
'Branch Reinforcement'
'Valves
'
'Piping
'
'Tubing
'
'Gaskets
'
'Bolts
'
'Nuts
'

100 - 299 values are for Piping Specialties


100 - 149 range of values are for specific specialties
150 - 199 range of values are for typical specialties
200 - 249 range of values are for specific valves
250 - 299 range of values are for typical valves
100
150
200
250

=
=
=
=

'Specific - General
'Typical - General
'Specific - Valve
'Typical - Valve

'
'
'
'

300 - 499 values are for Instruments


300 - 349 range of values are for
350 - 399 range of values are for
400 - 449 range of values are for
450 - 499 range of values are for

694

specific instruments
typical instruments
specific valves
typical values

Plant Design System (PDS) Piping Component Data

Codelists
300
350
400
450

=
=
=
=

'Specific - General
'Typical - General
'Specific - Valve
'Typical - Valve

'
'
'
'

CL999, Standard Note Title (2000)


In editing this codelist set, do not change the meaning of
existing codelist values.
1 = [Blank]
31 = 'Object Types for Mass Annotation'
35 = 'Approval Status'
36 = 'Structural Approval Status'
37 = 'HVAC Approval Status'
50 = 'Hold Status'
69 = 'Equipment Division'
125 = 'Fluid Code'
130 = 'Construction Status'
145 = 'Materials Grade'
148 = 'Materials Description'
160 = 'Responsibility'
180 = 'Fabrication Category'
190 = 'Coating Requirements'
200 = 'Heat Tracing Requirements'
210 = 'Heat Tracing Media'
220 = 'Insulation Purpose'
230 = 'Cleaning Requirements'
330 = 'End Preparation'
332 = 'Schedule / Thickness Override'
340 = 'Safety Classification'
360 = 'Stress Analysis Requirements'
365 = 'Reporting Requirements'
366 = 'Requirement to Reconstruct'
380 = 'Piping Component Type'
390 = 'Action'
400 = 'Commodity Option'
420 = 'Piping Component Data Source'
425 = 'Piping/Tubing Type/Source'
430 = 'Instrument Component Data Source'
499 = 'Piping Notes'
530 = 'Accessory / Item Type'
550 = 'Operator / Actuator Type'
570 = 'Design Standard'
572 = 'Wall Thickness Equation'
575 = 'Geometry Standard'
576 = 'Table Suffix / End Standard - Green'
577 = 'Table Suffix / End Standard - Red'
578 = 'Weight Code'
990 = 'Spec Writer Data Form Type'
999 = 'Standard Note Title'
1010 = 'Area Units'
1028 = 'Weight Units'
1056 = 'Temperature Units'

Plant Design System (PDS) Piping Component Data

695

Codelists
1064
1074
1100
1162
1201
1202
1203
1204
1205
1207
1208
1209
1310
1312
1410
1605
1610
1620
1630
1710
1720
1900
2000

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Pressure Units'
'Density Units'
'Weld Type'
'Force Units'
'Drawing Scale'
'Drawing Size'
'Interference Manager Approval Status'
'Interference Clash Type'
'Interference Manager Action'
'Interference Manager Approval Method'
'Clash Checking Option'
'Clash Checking Volume Filter Option'
'Report Source'
'Report Type'
'Design Review Type'
'Model Status'
'Force Units for FrameWorks Plus'
'Drawing View Direction'
'Drawing View Composition Status'
'Document Type'
'Document Sub-Type'
'Isometric Drawing Type'
'Orthographic Drawing Type'

CL1010, Area Units (25)


Unit in CL
No
Unit Name
1
ft^2
1.0*
E+00
3
in^2
6.944 444 E-03
5
yd^2
9.0*
E+00
7
mi^2
2.787 840 E+07
10
mm^2
1.076 391 E-05
12
cm^2
1.076 391 E-03
14
m^2
1.076 391 E+01
16
km^2
1.076 391 E+07
25
[Blank]
-9999.

696

Convert to Destination Unit

Convert To First

Dest. Unit
m^2

A
0.0

Factor
9.290 304* E-02

cm^2

6.451 6*

E+00

0.0

m^2

8.361 274

E-01

0.0

km^2

2.589 988

E+00

0.0

mm^2

mm^2

1.0*

E+02

0.0

cm^2

1.0*

E+04

0.0

m^2

1.0*

E+06

0.0

---

---

0.0

-9999.

Plant Design System (PDS) Piping Component Data

Codelists

CL1028, Mass Units (40)


Convert to Destination Unit
First Unit in CL
No
Unit Name
B
1
lb
1.0*
E+00
3
grain
1.428 571 E-04
9
USton
2.0*
E+03
11
UKton
2.24*
E+03
20
(Mu)g
2.204 622 E-09
22
mg
2.204 622 E-06
24
g
2.204 622 E-03
26
kg
2.204 622 E+00
28
Mg
2.204 622 E+03
40
[Blank]
-9999.

Convert To

Dest. Unit

Factor

kg

4.535 924

E-01

0.0

mg

6.479 891

E+01

0.0

Mg

9.071 847

E-01

0.0

Mg

1.016 047

E+00

0.0

(Mu)g

0.0

mg

0.0

0.0

kg

0.0

Mg

0.0

---

---

-9999.

CL1056, Temperature Units (15)


in CL
No
Unit Name
1
degF
E+00
2
degC
E+00
3
degR
E+00
4
K
E+00
15
[Blank]
-9999.

Convert to Destination Unit

Convert To First Unit

Dest. Unit
degC

Factor
(degF - 32)/1.8

A
0.0

degC

+3.2*

5/9

-4.596 900 E+02 0.0*

-4.596 900 E+02 1.8*

---

---

-9999.

Plant Design System (PDS) Piping Component Data

B
1.0*
E+01 1.8*

697

Codelists

CL1064, Pressure Units (40)


NOTE: New entries in this codelist cannot be added by the user.
Changes will NOT be recognized unless the software is changed to
use them.
Convert to Destination Unit
Convert To
First Unit in CL
No
Unit Name
Dest. Unit
Factor
A
B
1
psig [gage]
kPa
0.0
1.0*
E+00
2
psi [absolute]
kPa
6.894 757 E+00
-1.469 595
E+01 1.0*
E+00
4
inH2O [absolute]
kPa
2.488 4
E-01
-1.469 595
E+01 3.609 119 E-02
6
inH2O @ 32degF
kPa
2.491 14
E-01
-1.469 595
E+01 3.613 010 E-02
7
inHg [absolute]
kPa
3.376 85
E+00
-1.469 595
E+01 4.897 707 E-01
8
mmHg [absolute]
kPa
1.333 22
E-01
-1.469 595
E+01 1.933 672 E-02
9
atm [absolute]
kPa
1.013 250* E+02
-1.469 595
E+01 1.469 595 E+01
10
bar [absolute]
kPa
1.0*
E+02
-1.469 595
E+01 1.450 377 E+01
11
bar (gage) [gage]
psig
1.450 377 E+01
0.0
1.450 377 E+01
13
dyn/cm^2 [absolute]
Pa
1.0*
E-01
-1.469 595
E+01 1.450 377 E-05
15
mmH2O [absolute]
kPa
9.806 38
E-03
-1.469 595
E+01 1.422 295 E-03
16
inHg @ 32degF
kPa
3.386 38
E+00
-1.469 595
E+01 4.911 054 E-01
17
kPa [absolute]
kPa
1
-1.469 595
E+01 1.450 377 E-01
18
MPa [absolute]
kPa
1.0*
E+03
-1.469 595
E+01 1.450 377 E+02
19
Pa [absolute]
Pa
1
-1.469 595
E+01 1.450 377 E-04
20
kg/cm*2 (gage) [gage] psig
1.422 334 E+01
0.0
1.422 334 E+01
21
kg/cm*2 [absolute]
kPa
9.806 65
E+01
-1.469 595
E+01 1.422 334 E+01
22
Mpa_g
psig
1.450 377 E+02
0.0
1.450 377 E+02
40
[Blank]
-----9999.
-9999.
67
kPa_g
psig
1.450 377 E-01
0.0
1.450 377 E-01

698

Plant Design System (PDS) Piping Component Data

Codelists

CL1074, Density Units (35)

CL1100, Weld Type (100)


Codelist numbers 0-19 have been reserved for shop welds,
numbers 20-29 have been reserved for field welds, and 30-39 have
been reserved for offshore welds. In editing this codelist set, do not
change the meaning of existing codelist values.
1
2
11
21
22
23
24

=
=
=
=
=
=
=

[Blank]
'Pipe connector'
'Shop weld'
'Field weld at assembly site'
'Field weld at job site'
'Field weld at job site for loose flange'
'Field fit weld at job site'

CL1162, Force Units (40)


1
3
5
7
20
22
24
26
28
40

=
=
=
=
=
=
=
=
=
=

'lbf'
'kipf'
'UStonf'
'UKtonf'
'dyn'
'mN'
'N'
'kgf'
'kN'
[Blank]

Plant Design System (PDS) Piping Component Data

699

Codelists

CL1201, Drawing Scale (540)


(1-499) English System of Units
1 = [Blank]
104 = '=1/8"= 1' 0"'
108 = '=1/4"= 1' 0"'
112 = '=3/8"= 1' 0"'
116 = '=1/2"= 1' 0"'
124 = '=3/4"= 1' 0"'
132 = '=1"= 1' 0"'
164 = '=2"= 1' 0"'
(500-599) Metric System of Units
500 = '1:10'
510 = '1:4'
530 = '1:2'
540 = '1:1'

CL1202, Drawing Size (199)


(1-99) English System of Units
1 = 'A'
2 = 'B'
3 = 'C'
4 = 'D'
5 = 'E'
6 = 'F'
(100-199) Metric System of Units
101 = 'A0'
102 = 'A1'
103 = 'A2'
104 = 'A3'
105 = 'A4'

CL1203, Interference Manager Approval Status (99)


1 = 'Unapproved'
2 = 'Approved'
99 = 'Cleared'

[User has approved clash]


[Software detected that clash has been fixed]

CL1204, Interference Clash Type


1
2
3
4
5
6
105
106

700

=
=
=
=
=
=
=
=

'
'
'
'
'
'
'
'

Hard versus Hard'


;
Hard versus Soft'
;
Hard versus Construction'
;
Soft versus Soft'
;
Soft versus Construction'
;
Construct vs Construct=Construction versus Construction' ;
Hard vs Fproof'
;
Hard vs Insul'
;

Plant Design System (PDS) Piping Component Data

Codelists
110
111
112
113
120
121
122
123
206
220
221
222
223
501
502
504
505
506
510
511
512
513
520
521
522
523
602
604
606
620
621
622
623
1001
1002
1004
1005
1006
1010
1012
1013
1020
1021
1022
1023
1101
1102
1104
1105
1106
1110
1111
1112
1113

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'

Hard vs HardMaint'
Hard vs HardAccess'
Hard vs HardSafety'
Hard vs HardOperating'
Hard vs SoftMaint'
Hard vs SoftAccess'
Hard vs SoftSafety'
Hard vs SoftOperating'
Soft vs Insul'
Soft vs SoftMaint'
Soft vs SoftAccess'
Soft vs SoftSafety'
Soft vs SoftOperating'
Fproof vs Hard'
Fproof vs Soft'
Fproof vs CT'
Fproof vs Fproof'
Fproof vs Insul'
Fproof vs HardMain'
Fproof vs HardAccess'
Fproof vs HardSafety'
Fproof vs HardOperat'
Fproof vs HardMain'
Fproof vs HardAccess'
Fproof vs HardSafety'
Fproof vs HardOperat'
Insul vs Soft'
Insul vs CT'
Insul vs Insul'
Insul vs SoftMain'
Insul vs SoftAccess'
Insul vs SoftSafety'
Insul vs SoftOperat'
HardMain vs Hard'
HardMain vs Soft'
HardMain vs CT'
HardMain vs Fproof'
HardMain vs Insul'
HardMain vs HardMain'
HardMain vs HardSafety'
HardMain vs HardOperat'
HardMain vs SoftMain'
HardMain vs SoftAccess'
HardMain vs SoftSafety'
HardMain vs SoftOperat'
HardAcc vs Hard'
HardAcc vs Soft'
HardAcc vs CT'
HardAccess vs Fproof'
HardAccess vs Insul'
HardAcc vs HardMain'
HardAcc vs HardAcc'
HardAcc vs HardSafety'
HardAcc vs HardOperat'

Plant Design System (PDS) Piping Component Data

;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;

701

Codelists
1120
1121
1122
1123
1201
1202
1204
1205
1206
1210
1211
1212
1213
1220
1221
1222
1223
1301
1302
1304
1305
1306
1310
1311
1312
1313
1320
1321
1322
1323
2002
2004
2006
2020
2021
2022
2023
2102
2104
2106
2120
2121
2122
2123
2202
2204
2206
2220
2221
2222
2223
2302
2304
2306

702

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'
'

HardAcc vs SoftMain'
HardAcc vs SoftAcc'
HardAcc vs SoftSafety'
HardAcc vs SoftOperat'
HardSafety vs Hard'
HardSafety vs Soft'
HardSafety vs CT'
HardSafety vs Fproof'
HardSafety vs Insul'
HardSafety vs HardMain'
HardSafety vs HardAcc'
HardSafety vs HardSafety'
HardSafety vs HardOperat'
HardSafety vs SoftMain'
HardSafety vs SoftAccess'
HardSafety vs SoftSafety'
HardSafety vs SoftOperat'
HardOperat vs Hard'
HardOperat vs Soft'
HardOperat vs CT'
HardOperat vs Fproof'
HardOperat vs Insul'
HardOperat vs HardMain'
HardOperat vs HardAccess'
HardOperat vs HardSafety'
HardOperat vs HardOperat'
HardOperat vs SoftMain'
HardOperat vs SoftAccess'
HardOperat vs SoftSafety'
HardOperat vs SoftOperat'
SoftMain vs Soft'
SoftMain vs CT'
SoftMain vs Insul'
SoftMain vs SoftMain'
SoftMain vs SoftAccess'
SoftMain vs SoftSafety'
SoftMain vs SoftOperat'
SoftAccess vs Soft'
SoftAccess vs CT'
SoftAccess vs Insul'
SoftAccess vs SoftMain'
SoftAccess vs SoftAccess'
SoftAccess vs SoftSafety'
SoftAccess vs SoftOperat'
SoftSafety vs Soft'
SoftSafety vs CT'
SoftSafety vs Insul'
SoftSafety vs SoftMain'
SoftSafety vs SoftAccess'
SoftSafety vs SoftSafety'
SoftSafety vs SoftOperat'
SoftOperat vs Soft'
SoftOperat vs CT'
SoftOperat vs Insul'

;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;

Plant Design System (PDS) Piping Component Data

Codelists
2320
2321
2322
2323

=
=
=
=

'
'
'
'

SoftOperat
SoftOperat
SoftOperat
SoftOperat

vs
vs
vs
vs

SoftMain'
SoftAccess'
SoftSafety'
SoftOperat'

;
;
;
;

CL1205, Interference Manager Action (10)


1
2
3
4

=
=
=
=

'No Action by user'


'Approve Real Clash'
'Approve False Clash'
'Transfer Responsibility'

CL1207, Interference Manager Approval Method (10)


1 = 'Not Approved'
2 = 'Accepted by Graphical Review'
3 = 'Accepted from List'

CL1208, Clash Checking Option


1
2
3
4

=
=
=
=

'Unknown'
'Project Mode'
'Design Area Mode'
'Pre-defined Volume Mode'

CL1209, Clash Checking Volume Filter Option


1 = 'Volume Filter Is Inactive'
2 = 'Volume Filter Is Active'

CL1310, Report Source (99)


In editing this codelist set, do not change the meaning of
existing codelist values. Codelist values are reserved as follows:
0-10 from design data, 11-20 from project data, 21-30 reference
data.
1
2
3
11
12
21
22

=
=
=
=
=
=
=

'
'
'
'
'
'
'

MTO Report
Drawing Report
PID Report Header
Project Control Report
Clash Management Report
Piping Job Spec Report
Table Checker Report

'
'
'
'
'
'
'

CL1312, Report Type (999)


Document types defined below must be numerically identical
to those defined in CL1720, Document Type; codelist numbers used
must not exceed '999'. In editing this codelist set, do not change
the meaning of existing codelist values.

Plant Design System (PDS) Piping Component Data

703

Codelists
601
682
685
687
689
690
692
696

=
=
=
=
=
=
=
=

'Piping RDB Reports'


'Equipment List'
'Piping Line List'
'Piping Segments Report'
'Piping Components MTO Report'
'Pipe Supports Report'
'Instrument List'
'Piping Release Report'

CL1410, Design Review Type (10)


In editing this codelist set, do not change the meaning of
existing codelist values.
1 = 'Client Review'
2 = 'Informal Review'

CL1605, Model Status


1
11
12
21

=
=
=
=

'Undefined'
'Preliminary'
'Temporary'
'Permanent'

CL1610, Force Units for FrameWorks Plus (40)


1
2
3
4

704

=
=
=
=

'LBS'
'KIPS'
'N'
'kN'

Plant Design System (PDS) Piping Component Data

Codelists

CL1620, Drawing View Directions (7)


1
2
3
4
5
6
7

=
=
=
=
=
=
=

'Plan'
'East Elevation'
'North Elevation'
'Isometric'
'West Elevation'
'South Elevation'
'Plan (Vertical)'

CL1630, Drawing View Composition Status (4)


1
2
3
4

=
=
=
=

'Drawing View Not Composed'


'Drawing View Composed'
'Composite Drawing View Not Composed'
'Composite Drawing View Composed'

CL1710, Document Source (99)


Do not make any new entries to this codelist. In editing
this codelist set, do not change the meaning of existing codelist values.
1
2
5
11
12
15
21
22
25
31
32
35
41
42
45
46
47
51
52
55
61
62
65
67
71
72
75

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'Process RDB report'


'Process TDB report'
'Process TDB drawing'
'P&I RDB report'
'P&I TDB report'
'P&I TDB drawing'
'Vessel RDB report'
'Vessel TDB report'
'Vessel TDB drawing'
'Heat Transfer RDB report'
'Heat Transfer TDB report'
'Heat Transfer TDB drawing'
'Mechanical RDB report'
'Mechanical TDB report'
'Mechanical TDB drawing'
'Piping Specialty RDB report'
'Piping Specialty TDB report'
'Civil/Structural RDB report'
'Civil/Structural TDB report'
'Civil/Structural TDB drawing'
'Piping RDB report'
'Piping TDB report (PD_Report)'
'Piping TDB drawing (PD_Draw)'
'Piping isometric TDB drawing'
'Instrument RDB report'
'Instrument TDB report'
'Instrument TDB drawing'

Plant Design System (PDS) Piping Component Data

705

Codelists
81
82
85
91
92
95
99

=
=
=
=
=
=
=

'Electrical RDB report'


'Electrical TDB report'
'Electrical TDB drawing'
'HVAC RDB report'
'HVAC TDB report'
'HVAC TDB drawing'
'No planned PDS source'

CL1720, Document Type (999)


The PDS source of each document type is shown to the right
of the document type separated from it by the character '|' on the
basis of codelist numbers defined in CL1710, Document Source. In
editing this codelist set, respect the number ranges identified below.
(100-199) Process Documents
101 = 'Process RDB Reports | 1'
121 = 'Process Flow Diagrams | 5'
125 = 'Materials of Construction Drawings | 5'
127 = 'Temperature/Pressure Diagrams | 5'
131 = 'Equipment Process Datasheets | 2'
133 = 'Instrument Process Datasheets | 2'
199 = 'Other Process Documents | 99'
(200-299) Vessel Documents
201 = 'Vessel RDB Reports | 21'
205 = 'Vessel Job Specifications | 99'
211 = 'Vessel Requisitions | 22'
231 = 'Reactor Drawings | 25'
233 = 'Regenerator Drawings | 25'
235 = 'Cyclone Drawings | 25'
237 = 'Transfer Line Drawings | 25'
239 = 'Tower Drawings | 25'
241 = 'Drum Drawings | 25'
243 = 'Tank Drawings | 25'
245 = 'Silo Drawings | 25'
247 = 'Stack Drawings | 25'
299 = 'Other Vessel Documents | 99'
(300-399) Heat Transfer Documents
301 = 'Heat Transfer RDB Reports | 31'
305 = 'Heat Transfer Job Specifications | 99'
311 = 'Heat Transfer Requisitions | 32'
331 = 'Heat Transfer Drawings | 35'
399 = 'Other Heat Transfer Documents | 99'
(400-499) Mechanical Equipment Documents
401 = 'Mechanical RDB Reports | 41'
405 = 'Mechanical Equipment Job Specifications | 99'
411 = 'Mechanical Equipment Requisitions | 42'
431 = 'Mechanical Equipment Drawings | 45'
499 = 'Other Mechanical Equipment Documents | 99'

706

Plant Design System (PDS) Piping Component Data

Codelists
(500-599) Civil/Structural Documents
501 = 'Civil/Structural RDB Reports | 51'
505 = 'Civil/Structural Job Specifications | 99'
511 = 'Civil/Structural Requisitions | 99'
531 = 'Site Preparation Drawings | 99'
535 = 'Foundation Location Drawings | 65'
537 = 'Piling Drawings | 65'
538 = 'Foundation Drawings | 55'
540 = 'Structural Perspectives, Plans, Sections and Details | 65'
545 = 'Concrete Structural Drawings | 55'
550 = 'Steel Structural Drawings | 55'
570 = 'Building Drawings | 99'
599 = 'Other Civil/Structural Documents | 99'
(600-699) Piping Documents
601 = 'Piping RDB Reports | 61'
602 = 'Piping Specialty RDB Reports | 46'
605 = 'Piping Job Specifications | 99'
611 = 'Piping Commodity Requisitions | 99'
612 = 'Piping Specialty Requisitions | 47'
631 = 'P&IDs | 15'
633 = 'Hydrotest P&IDs | 15'
641 = 'Plot Plans | 65'
643 = 'Equipment Arrangement Drawings | 65'
651 = 'Piping Underground Drawings | 65'
661 = 'Equipment Orientations | 65'
663 = 'Piping One Line Drawings | 65'
665 = 'Piping Perspectives, Plans, Sections and Details | 65'
667 = 'Pipeline Alignment Drawings | 65'
669 = 'Piping Isometric Drawings | 67'
671 = 'Piping Spool Drawings | 67'
673 = 'Spring Hanger Drawings | 99'
675 = 'Pipe Support Details | 99'
681 = 'P&ID Equipment List | 12'
682 = 'Equipment List | 62'
684 = 'P&ID Line List | 12'
685 = 'Piping Line List | 62'
687 = 'Piping Segments Report | 62'
689 = 'Piping Components MTO Report | 62'
690 = 'Pipe Supports Report | 62'
692 = 'Instrument List | 62'
696 = 'Piping Release Report | 62'
699 = 'Other Piping Documents | 99'

Plant Design System (PDS) Piping Component Data

707

Codelists
(700-799) Instrument Documents
701 = 'Instrument RDB Reports | 71'
705 = 'Instrument Job Specifications | 99'
711 = 'Instrument Requisitions | 72'
721 = 'Instrument Logic Diagrams | 75'
723 = 'Instrument Loop Diagrams | 75'
731 = 'Instrument Location Plans | 65'
733 = 'Instrument Control House/Panel Drawings | 99'
735 = 'Instrument Hook Up Drawings | 75'
737 = 'Instrument Heat Tracing Drawings | 75'
739 = 'Instrument Wiring Drawings | 99'
771 = 'Instrument Index | 72'
799 = 'Other Instrument Documents | 99'
(800-899) Electrical Documents
801 = 'Electrical RDB Reports | 81'
805 = 'Electrical Job Specifications | 99'
811 = 'Electrical Requisitions | 99'
831 = 'Electrical One Line Diagrams | 99'
841 = 'Electrical Area Classification Drawings | 65'
851 = 'Electrical Underground Drawings | 65'
861 = 'Electrical Power Drawings | 99'
863 = 'Electrical Communications Drawings | 99'
865 = 'Lighting Perspectives, Plans, Sections and Details | 65'
867 = 'Electrical Heat Tracing Drawings | 99'
899 = 'Other Electrical Documents | 99'
(900-999) HVAC Documents
901 = 'HVAC RDB Reports | 91'
905 = 'HVAC Job Specifications | 99'
911 = 'HVAC Requisitions | 99'
931 = 'HVAC Flow Diagrams | 99'
971 = 'HVAC Perspectives, Plans, Sections and Details | 65'
999 = 'Other HVAC Documents | 99'

CL1900, Isometric Drawing Type


In editing this codelist set, do not change the meaning
of existing codelist values. Some data displays require that only
values to the left of the "=" sign be shown; other reports require
that only values to the right of the "=" sign be displayed.
1 = 'Fabrication'
2 = 'Spool'
3 = 'Stress'

708

Plant Design System (PDS) Piping Component Data

Codelists

CL2000, PD_Draw Document Type (999)


Document types defined below must be numerically identical
to those defined in CL1720, Document Type; codelist numbers used
must not exceed '999'. In editing this codelist set, do not change
the meaning of existing codelist values.
535
537
540
641
643
651
661
663
665
667
731
841
851
865
971

=
=
=
=
=
=
=
=
=
=
=
=
=
=
=

'
'
'
'
'
'
'
'
'
'
'
'
'
'
'

Foundation Location Drawings'


Piling Drawings'
Structural Perspectives, Plans, Sections and Details'
Plot Plans'
Equipment Arrangement Drawings'
Piping Underground Drawings'
Equipment Orientations'
Piping One Line Drawings'
Piping Perspectives, Plans, Sections and Details'
Pipeline Alignment Drawings'
Instrument Location Plans'
Electrical Area Classification Drawings'
Electrical Underground Drawings'
Lighting Perspectives, Plans, Sections and Details'
HVAC Perspectives, Plans, Sections and Details'

Plant Design System (PDS) Piping Component Data

709

Index
6
6P4C30, Wet sprinkler (on-line) 148
6P4C31, Pre-action sprinkler (on-line) 149
6P4C32, Spray sprinkler (on-line) 149
6P6C17, Spray nozzle (on-line) (PID piping
comp type 529) 169
6Q1C01, Gate valve (in-line) 50
6Q1C02, Extended body gate valve (in-line)
51
6Q1C03, Conduit gate valve (in-line) 52
6Q1C04, Blank gate valve (in-line) 52
6Q1C05, 3-way valve (in-line) 53
6Q1C06, [2-way] ball valve (in-line) 53
6Q1C08, 3-way ball valve (in-line) 54
6Q1C11, [2-way] globe valve (in-line) 55
6Q1C12, [2-way] angle globe valve (in-line)
56
6Q1C13, 3-way globe valve (in-line) 57
6Q1C14, Y globe valve (in-line) 57
6Q1C16, [2-way] plug valve (in-line) 58
6Q1C18, 3-way plug valve (in-line) 60
6Q1C19, 4-way plug valve (in-line) 60
6Q1C22, Needle valve (in-line) 60
6Q1C26, Butterfly valve (in-line) 60
6Q1C30, Diaphragm valve (in-line) 61
6Q1C32, Knife gate valve (in-line) 62
6Q1C33, [2-way] slide valve (in-line) 62
6Q1C34, 3-way slide valve (in-line) 63
6Q1C37, Angle valve (in-line) 64
6Q1C38, Check valve (in-line) (directional)
64
6Q1C39, Wafer check valve (in-line)
(directional) 67
6Q1C40, Angle check valve (in-line)
(directional) 67
6Q1C41, Stop check valve (in-line)
(directional) 68
6Q1C42, Angle stop check valve (in-line)
(directional) 68
6Q1C43, Y stop check valve (in-line)
(directional) 68
6Q1C50, Backflow preventer (in-line)
(directional) 69
6Q1C51, Automatic recirculation valve
(in-line) (directional) 69
6Q1C53, Angle blowdown valve (in-line) 69
6Q1C54, Y blowdown valve (in-line) 70
6Q1C56, Pinch valve (in-line) 70

Plant Design System (PDS) Piping Component Data

6Q1C57, Float valve (in-line) 70


6Q1C58, Foot valve (in-line) (directional)
70
6Q1C62, Tank drain valve (in-line)
(directional) 71
6Q1C69, Deluge valve (in-line) 71
6Q1C72, Hose valve (in-line) 71
6Q1C73, Angle hose valve (in-line) 72
6Q1C76, Vent-drain valve (in-line) 72
6Q1C80, Instrument root valve (in-line) 72
6Q1C81, 3-way instrument root valve
(in-line) 73
6Q1C82, 4-way instrument root valve
(yn-line) 73
6Q2C01, Flange (in-line) 80
6Q2C03, Reducing flange (in-line)
(not-automatic) 83
6Q2C04, Expander flange (in-line)
(not-automatic) 84
6Q2C06, Orifice flange (in-line)
(not-automatic) 84
6Q2C08, Blind flange (in-line)
(not-automatic) 86
6Q2C10, Open spectacle blank (in-line)
(not-automatic) 87
6Q2C11, Closed spectacle blank (in-line)
(not-automatic) 87
6Q2C12, Blank disc (in-line) (not-automatic)
87
6Q2C13, Blind spacer (in-line)
(not-automatic) 87
6Q2C14, Tapered spacer (in-line)
(not-automatic) 87
6Q2C15, Open spacer (in-line)
(not-automatic) 88
6Q2C16, End (in-line) (not-automatic) 88
6Q2C17, Head (in-line) (not-automatic) 88
6Q2C19, Plug (in-line) (not-automatic) 89
6Q2C21, Cap (in-line) (not-automatic) 89
6Q2C23, Concentric diameter change
(in-line) 89
6Q2C24, Eccentric diameter change (in-line)
(not-automatic) 89
6Q2C25, Coupling-connector (in-line)
(not-automatic) 89
6Q2C26, Half coupling (in-line)
(not-automatic) 90
6Q2C27, Concentric reducer (in-line) 91

711

Index
6Q2C28, Eccentric reducer (in-line)
(not-automatic) 92
6Q2C32, Reducing coupling (in-line)
(not-automatic) 92
6Q2C35, Concentric swage (in-line) 93
6Q2C36, Eccentric swage (in-line)
(not-automatic) 93
6Q2C39, Union (in-line) (not-automatic) 94
6Q2C40, Orifice union (in-line)
(not-automatic) 94
6Q2C41, Dielectric union (in-line)
(not-automatic) 94
6Q2C43, Hose connection (in-line)
(not-automatic) 94
6Q2C44, Bushing (in-line) (not-automatic)
95
6Q2C46, Reducing insert (in-line)
(not-automatic) 95
6Q2C47, Pipe bend (in-line) 95
6Q2C49, 5.625 deg elbow (in-line)
(not-automatic) 96
6Q2C51, 11.25 deg elbow (in-line)
(not-automatic) 96
6Q2C53, 22.5 deg elbow (in-line)
(not-automatic) 97
6Q2C55, <45 deg direction change (in-line)
97
6Q2C56, 45 deg direction change (in-line)
98
6Q2C57, 45 deg elbow (in-line) 98
6Q2C59, 45 deg LR elbow (in-line) 99
6Q2C60, 45 deg long tangent elbow (in-line)
99
6Q2C61, 45 deg 3D elbow (in-line) 100
6Q2C63, 45 deg union elbow (in-line)
(not-automatic) 100
6Q2C65, 45 deg street elbow (in-line)
(not-automatic) 100
6Q2C66, 45 deg short elbow (in-line) 101
6Q2C68, 45 deg long elbow (in-line) 101
6Q2C73, 60 deg elbow (in-line)
(not-automatic) 101
6Q2C75, 45-90 deg direction change
(in-line) 101
6Q2C76, 90 deg direction change (in-line)
102
6Q2C77, 90 deg elbow (in-line) 102
6Q2C79, 90 deg SR elbow (in-line) 103
6Q2C80, 90 deg LR elbow (in-line) 103
6Q2C82, 90 deg LR long tangent elbow
(in-line) 104
6Q2C84, 90 deg reducing elbow (in-line)
104

712

6Q2C86, 90 deg 3D elbow (in-line) 104


6Q2C88, 90 deg union elbow (in-line)
(not-automatic) 105
6Q2C90, 90 deg street elbow (in-line)
(not-automatic) 105
6Q2C91, 90 deg reducing street elbow
(in-line) (not-automatic) 105
6Q2C93, 90 deg short elbow (in-line) 106
6Q2C94, 90 deg long elbow (in-line) 106
6Q3C01, 180 deg return (in-line)
(not-automatic) 112
6Q3C03, 180 deg SR return (in-line)
(not-automatic) 112
6Q3C05, 180 deg LR return (in-line)
(not-automatic) 112
6Q3C07, 180 deg close return (in-line)
(not-automatic) 112
6Q3C08, 180 deg medium return (in-line)
(not-automatic) 113
6Q3C09, 180 deg open return (in-line)
(not-automatic) 113
6Q3C14, Miter (in-line) (not-automatic) 113
6Q3C16, 45 deg miter (in-line) 114
6Q3C18, 90 deg miter (in-line) 115
6Q3C22, Tee (in-line) 116
6Q3C24, Reducing branch tee (in-line) 117
6Q3C25, Reducing run and branch tee
(in-line) 119
6Q3C27, On-run union tee (in-line)
(not-automatic) 119
6Q3C28, On-branch union tee (in-line)
(not-automatic) 119
6Q3C31, Street tee (in-line) (not-automatic)
120
6Q3C34, Reducing instrument tee (in-line)
(not-automatic) 120
6Q3C36, Drip ring tee (in-line)
(not-automatic) 120
6Q3C38, Basin tee (in-line) 121
6Q3C45, True Y (in-line) (not-automatic)
121
6Q3C47, Lateral (in-line) 121
6Q3C49, Reducing branch lateral (in-line)
122
6Q3C50, Reducing run and branch lateral
(in-line) 123
6Q3C52, 90 deg short Y-branch (in-line)
(not-automatic) 123
6Q3C53, 90 deg reducing short Y-branch
(in-line) (not-automatic) 123
6Q3C54, 90 deg long Y-branch (in-line)
(not-automatic) 123

Plant Design System (PDS) Piping Component Data

Index
6Q3C55, 90 deg reducing long Y-branch
(in-line) (not-automatic) 124
6Q3C60, Cross (in-line) (not-automatic)
124
6Q3C62, Reducing branches cross (in-line)
(not-automatic) 125
6Q3C63, Reducing run and branches cross
(in-line) (not-automatic) 125
6Q3C64, Basin cross (in-line)
(not-automatic) 126
6Q3C70, Saddle (in-line) 126
6Q3C72, Sweepolet (in-line) 126
6Q3C73, Weldolet (in-line) 127
6Q3C74, Sockolet (in-line) 127
6Q3C75, Thredolet (in-line) 128
6Q3C76, Nippolet (in-line) 128
6Q3C77, Elbolet (in-line) (not-automatic)
129
6Q3C78, Latrolet (in-line) (not-automatic)
129
6Q3C79, Endolet (in-line) (not-automatic)
130
6Q3C80, Reinforcing pad (in-line) 130
6Q3C82, Reinforcing weld (in-line) 132
6Q3C83, Non-radial Reinforcing Weld 229
6Q3C84, Buttweld (in-line) (not-automatic)
134
6Q3C86, Full Encirclement Reinforcement
Pad (In-Line) 134
6Q3C88, Branch nipple (in-line)
(not-automatic) 134
6Q3C89, In-line nipple (in-line)
(not-automatic) 135
6Q3C95, Gasket 135
6Q3C97, Stud 137
6Q4C01, Fire monitor (in-line) 145
6Q4C02, Elevated fire monitor (in-line) 145
6Q4C03, Remotely operated fire monitor
(in-line) 145
6Q4C04, Foam monitor (in-line) 146
6Q4C05 Elevated foam monitor (in-line)
146
6Q4C06, Remotely operated foam monitor
(in-line) 146
6Q4C10, [2-way] fire hydrant (in-line) 147
6Q4C11, [2-way] fire hydrant w/monitor
nozzle (in-line) 147
6Q4C13, 3-way fire hydrant (in-line) 147
6Q4C24, Hose reel (in-line) 148
6Q4C25, Hose rack station (in-line) 148
6Q4C26, Foam chamber (in-line) 148
6Q4C38, Eye wash (in-line) 149
6Q4C39, Safety shower (in-line) 149

Plant Design System (PDS) Piping Component Data

6Q4C40, Safety shower and eye wash


(in-line) 149
6Q4C60, [2-way] siamese (in-line) 150
6Q4C66, [2-way] 90 deg siamese (in-line)
150
6Q5P01, Ferrule (in-line) (not-automatic)
150
6Q5P02, Short ferrule (in-line)
(not-automatic) 151
6Q5P03, Extended tangent cap (in-line)
(not-automatic) 151
6Q5P04, Solid end cap (in-line)
(not-automatic) 151
6Q5P05, Hose adapter (in-line)
(not-automatic) 151
6Q5P06, Female adapter (in-line)
(not-automatic) 151
6Q5P07, Reducing female adapter (in-line)
(not-automatic) 152
6Q5P08, Male adapter (in-line)
(not-automatic) 152
6Q5P09, Reducing male adapter (in-line)
(not-automatic) 152
6Q5P10, 90 deg tube bend (in-line)
(not-automatic) 152
6Q5P11, 90 deg tube bend (in-line)
(not-automatic) 153
6Q5P12, 90 deg elbow (in-line)
(not-automatic) 153
6Q5P13, 45 deg tube bend (in-line)
(not-automatic) 153
6Q5P14, 45 deg tube bend (in-line)
(not-automatic) 153
6Q5P15, 45 deg elbow (in-line)
(not-automatic) 153
6Q5P16, 180 deg return bend (in-line)
(not-automatic) 154
6Q5P17, Use point 180 deg return (in-line)
(not-automatic) 161
6Q5P18, Use point 180 deg return (in-line)
(not-automatic) 161
6Q5P19, 180 deg return bend (in-line)
(not-automatic) 154
6Q5P21, Tee (in-line) (not-automatic) 154
6Q5P22, Reducing tee (in-line)
(not-automatic) 154
6Q5P23, Tee (in-line) (not-automatic) 154
6Q5P24, Reducing tee (in-line)
(not-automatic) 155
6Q5P25, Short outlet tee (in-line)
(not-automatic) 155
6Q5P26, Short outlet reducing tee (in-line)
(not-automatic) 155

713

Index
6Q5P27, Instrument tee (in-line)
(not-automatic) 155
6Q5P28, Short outlet run tee (in-line)
(not-automatic) 155
6Q5P31, Cross (in-line) (not-automatic)
156
6Q5P32, Reducing cross (in-line)
(not-automatic) 156
6Q5P33, Cross (in-line) (not-automatic)
156
6Q5P35, Tee (in-line) (not-automatic) 156
6Q5P36, Reducing tee (in-line)
(not-automatic) 156
6Q5P37, Short outlet tee (in-line)
(not-automatic) 157
6Q5P38, Short outlet reducing tee (in-line)
(not-automatic) 157
6Q5P39, Instrument tee (in-line)
(not-automatic) 157
6Q5P41, Concentric reducer (in-line)
(not-automatic) 157
6Q5P42, Concentric reducer (in-line)
(not-automatic) 157
6Q5P43, Concentric reducer (in-line)
(not-automatic) 158
6Q5P45, Eccentric reducer (in-line)
(not-automatic) 158
6Q5P46, Eccentric reducer (in-line)
(not-automatic) 158
6Q5P47, Eccentric reducer (in-line)
(not-automatic) 158
6Q5P51, Clamp, adjustable (in-line)
(not-automatic) 158
6Q5P52, Clamp, heavy duty (in-line)
(not-automatic) 159
6Q5P53, Clamp, 3 piece heavy duty (in-line)
(not-automatic) 159
6Q5P54, Clamp, pressure adjustable
(in-line) (not-automatic) 159
6Q5P55, Clamp, high pressure (in-line)
(not-automatic) 159
6Q5P56, Clamp, assembly (in-line)
(not-automatic) 159
6Q5P57, Clamp, swivel joint (in-line)
(not-automatic) 160
6Q5P58, Clamp, 2 piece heavy duty (in-line)
(not-automatic) 160
6Q5P60, 2-way diaphragm valve (in-line)
(not-automatic) 160
6Q5P61, 2-way diaphragm valve (in-line)
(not-automatic) 160
6Q5P62, Zero deadleg T valve (in-line)
(not-automatic) 161

714

6Q5P63, Zero deadleg T valve (in-line)


(not-automatic) 161
6Q5P65, Close-coupled branch valve
(in-line) (not-automatic) 162
6Q5P66, Close-coupled branch valve
(in-line) (not-automatic) 162
6Q5P68, Use point close-coupled branch
valve (in-line) (not-automatic) 162
6Q5P69, Use point close-coupled branch
valve (in-line) (not-automatic) 162
6Q5P75, 3 way diverter valve (in-line)
(not-automatic) 163
6Q5P76, 3 way diverter valve (in-line)
(not-automatic) 163
6Q5P77, 4 way diverter valve (in-line)
(not-automatic) 163
6Q5P78, 4 way diverter valve (in-line)
(not-automatic) 163
6Q6C01, Flame arrestor (in-line) (PID
piping comp type 513) 168
6Q6C03, Hammer arrestor (in-line) (PID
piping comp type 515) 168
6Q6C04, Vent silencer (in-line) (PID piping
comp type 516) 168
6Q6C05, In-line silencer (in-line) (PID
piping comp type 517) 168
6Q6C07, Exhaust head (in-line) (PID
piping comp type 519) 169
6Q6C09, Breather vent (in-line) (PID piping
comp type 521) 169
6Q6C11, Free vent w/o screen (in-line)
(PID piping comp type 523) 169
6Q6C12, Free vent w/screen (in-line) (PID
piping comp type 524) 169
6Q6C13, Motor operated valve (in-line)
(with operator) 169
6Q6C15, Mixing T (in-line) (PID piping
comp type 527) 169
6Q6C21, Removable spool (in-line) (PID
piping comp type 533) 170
6Q6C23, Swing elbow (in-line) (PID piping
comp type 535) 170
6Q6C28, Expansion joint (in-line) (PID
piping comp type 540) 170
6Q6C30, Hinged expansion joint (in-line)
(PID piping comp type 542) 170
6Q6C32, Swivel joint (in-line) (PID piping
comp type 544) 170
6Q6C34, Mechanical coupling (in-line)
(PID piping comp type 546) 171
6Q6C36, Flexible hose (in-line) (PID piping
comp type 548) 171

Plant Design System (PDS) Piping Component Data

Index
6Q6C40, Sample cooler (in-line) (PID
piping comp type 552) 172
6Q6C45, Single basket strainer (in-line)
(PID piping comp type 557) 172
6Q6C47, Duplex basket strainer (in-line
with operator) (PID piping comp type
559) 172
6Q6C49, T strainer (in-line) (PID piping
comp type 561) 172
6Q6C51, Y strainer (in-line) (PID piping
comp type 563) 173
6Q6C52, Temporary strainer (in-line) (PID
piping comp type 564) 173
6Q6C53, Basket strainer (in-line) (PID
piping comp type 565) 173
6Q6C55, Cone strainer (in-line) (PID piping
comp type 567) 174
6Q6C57, Flat plate strainer (in-line) (PID
piping comp type 569) 174
6Q6C59, Sump strainer (in-line) (PID
piping comp type 571) 174
6Q6C64, Filter (in-line) (PID piping comp
type 576) 174
6Q6C70, Steam trap (in-line) (PID piping
comp type 582) 174
6Q6C71, Float steam trap (in-line) (PID
piping comp type 583) 174
6Q6C72, Inverted bucket steam trap
(in-line) (PID piping comp type 584) 174
6Q6C74, Thermostatic steam trap (in-line)
(PID piping comp type 586) 174
6Q6C76, Thermodynamic steam trap
(in-line) (PID piping comp type 588) 174
6Q6C78, Impulse steam trap (in-line) (PID
piping comp type 590) 174
6Q6C99, Generic component (in-line) (PID
piping comp type 611) 175

7
7P1E01, [2-way generic body] control valve
(in-line) 181
7P1E02, [2-way generic body] angle control
valve (in-line) 181
7P1E03, 3-way [generic body] control valve
(in-line) 181
7P1E04, 4-way [generic body] control valve
(in-line) 181
7P1E05, [2-way] angle globe control valve
(in-line) 181
7P1E06, 3-way globe control valve (in-line)
181
7P1E07, [2-way] solenoid valve (in-line)
181

Plant Design System (PDS) Piping Component Data

7P1E08, [2-way] angle solenoid valve


(in-line) 182
7P1E09, 3-way solenoid valve (in-line) 182
7P1E10, 4-way solenoid valve (in-line) 182
7P1E11, 3-way plug control valve (in-line)
182
7P1E12, 4-way plug control valve (in-line)
182
7P1E13, [2-way] ball control valve (in-line)
182
7P1E14, 3-way ball control valve (in-line)
182
7P1E15, [2-way] globe control valve (in-line)
183
7P1E16, [2-way] plug control valve (in-line)
183
7P1E17, [2-way] butterfly control valve
(in-line) 183
7P1E18, [2-way] knife gate control valve
(in-line) 183
7P1E19, [2-way] diaphragm control valve
(in-line) 183
7P1E20, [2-way] slide control valve (in-line)
183
7P1E21, 3-way slide control valve (in-line)
183
7P1E22, [2-way] multivane 1 damp/louv CV
(in-line) 184
7P1E23, [2-way] multivane 2 damp/louv CV
(in-line) 184
7P1E24, [2-way] single vane damp/louv CV
(in-line) 184
7P1E27, Control valve w/equip (in-line) 184
7P1E30, Automatic recirculation valve
(in-line) 184
7P1E33, Self contained press red reg
(in-line) 184
7P1E34, Press red reg w/ ext tap (in-line)
185
7P1E35, Press red reg w/ int RV (in-line)
185
7P1E38, Self contained backpress reg
(in-line) 185
7P1E39, Backpress reg w/ ext tap (in-line)
185
7P1E42, Diff press red reg w/int & ext taps
(in-line) 185
7P1E44, [2-way] filled system temp reg
(in-line) 185
7P1E45, [2-way] angle filled system temp
reg (in-line) 185
7P1E46, 3-way filled system temp reg
(in-line) 186

715

Index
7P2C01, Angle press relief valve (in-line)
190
7P2C06, Straight-thru press relief valve
(in-line) 190
7P2C09, Vac relief valve (in-line) 190
7P2C12, Press/vac relief valve (in-line) 191
7P2C14, Press/vac relief manhole cover
(in-line) 191
7P2C16, Press relief rupture disc (in-line)
191
7P2C18, Vac relief rupture disc (in-line)
191
7P2C20, Temp fusible plug or disc (in-line)
191
7P3C01, Balloon instr (in-line) 196
7P3C02, Restriction orif union (in-line) 196
7P3C03, Valve w/restriction orif (in-line)
196
7P3C04, Orif plate (in-line) 196
7P3C05, Orif plate & flanges (in-line) 196
7P3C06, Orif plate, flanges & meter run
(in-line) 197
7P3C09, Orif plate & qk chnge fitting (in-line)
197
7P3C10, Orif pl, qk chnge fitting & met run
(in-line) 197
7P3C13, Venturi tube (in-line) 197
7P3C16, In-line averaging pitot tube (in-line)
197
7P3C19, Flow nozzle (in-line) 197
7P3C22, Var area flow instr (in-line) 198
7P3C23, Var area flow instr w/upstr reg
(in-line) 198
7P3C24, Var area flow instr w/dwnstr reg
(in-line) 198
7P3C25, Var area flow instr w/upstr vlv
(in-line) 198
7P3C26, Var area flow instr w/dwnstr vlv
(in-line) 198
7P3C29, Pos displacement flow instr
(in-line) 198
7P3C30, Pos displ flow instr w/dwnstr reg
(in-line) 199
7P3C33, In-line target flow instr (in-line)
199
7P3C35, In-line propeller flow instr (in-line)
199
7P3C37, Vortex flow instr (in-line) 199
7P3C39, In-line magnetic flow instr (in-line)
199
7P3C41, In-line ultrasonic flow instr (in-line)
199
7P3C44, Flume (in-line) 200

716

7P3C46, Weir (in-line) 200


7P3C48, Segmental wedge (in-line) 200
7P3C50, Flow straightening vane (in-line)
200
7P3C53, Trap (in-line) 200
7P3C56, Vent silencer (in-line) 201
7P3C57, In-line silencer (in-line) 201
7Q4D01, Discrete [field mounted AE
(off-line) 206
7Q4D02, Discrete [field mounted] AP
(off-line) 206
7Q4D03, Discrete [field mounted] AT
(off-line) 206
7Q4D06, Discrete [field mounted] FC
(off-line) 206
7Q4D07, Discrete [field mounted] FI
(off-line) 206
7Q4D08, Discrete [field mounted] FIC
(off-line) 206
7Q4D09, Discrete [field mounted] FP
(off-line) 207
7Q4D10, Discrete [field mounted] FR
(off-line) 207
7Q4D11, Discrete [field mounted] FRC
(off-line) 207
7Q4D12, Discrete [field mounted] FSH
(off-line) 207
7Q4D13, Discrete [field mounted] FSL
(off-line) 207
7Q4D14, Discrete [field mounted] FSM
(off-line) 207
7Q4D15, Discrete [field mounted] FSHH
(off-line) 208
7Q4D16, Discrete [field mounted] FSHL
(off-line) 208
7Q4D17, Discrete [field mounted] FSLL
(off-line) 208
7Q4D18, Discrete [field mounted] FT
(off-line) 208
7Q4D21, Discrete [field mounted] LC
(off-line) 208
7Q4D22, Discrete [field mounted] LG
(off-line) 209
7Q4D23, Discrete [field mounted] LI
(off-line) 209
7Q4D24, Discrete [field mounted] LIC
(off-line) 209
7Q4D25, Discrete [field mounted] LR
(off-line) 210
7Q4D26, Discrete [field mounted] LRC
(off-line) 210
7Q4D27, Discrete [field mounted] LSH
(off-line) 210

Plant Design System (PDS) Piping Component Data

Index
7Q4D28, Discrete [field mounted] LSL
(off-line) 210
7Q4D29, Discrete [field mounted] LSM
(off-line) 210
7Q4D30, Discrete [field mounted] LSHH
(off-line) 211
7Q4D31, Discrete [field mounted] LSHL
(off-line) 211
7Q4D32, Discrete [field mounted] LSLL
(off-line) 211
7Q4D33, Discrete [field mounted] LT
(off-line) 211
7Q4D35, Discrete [field mounted] PC
(off-line) 212
7Q4D36, Discrete [field mounted] PDIC
(off-line) 212
7Q4D37, Discrete [field mounted] PDSH
(off-line) 212
7Q4D38, Discrete [field mounted] PDSL
(off-line) 212
7Q4D39, Discrete [field mounted] PDT
(off-line) 212
7Q4D40, Discrete [field mounted] PI
(off-line) 212
7Q4D41, Discrete [field mounted] PIC
(off-line) 213
7Q4D42, Discrete [field mounted] PP
(off-line) 213
7Q4D43, Discrete [field mounted] PR
(off-line) 213
7Q4D44, Discrete [field mounted] PRC
(off-line) 213
7Q4D45, Discrete [field mounted] PSH
(off-line) 213
7Q4D46, Discrete [field mounted] PSL
(off-line) 213
7Q4D47, Discrete [field mounted] PSM
(off-line) 214
7Q4D48, Discrete [field mounted] PSHH
(off-line) 214
7Q4D49, Discrete [field mounted] PSHL
(off-line) 214
7Q4D50, Discrete [field mounted] PSLL
(off-line) 214
7Q4D51, Discrete [field mounted] PT
(off-line) 214
7Q4D53, [Field mounted] pilot light (off-line)
214
7Q4D57, Discrete single-funct, [field
mounted] instr (off-line) 215
7Q4D58, Discrete multi-funct, [field
mounted] instr (off-line) 215

Plant Design System (PDS) Piping Component Data

7Q4D60, Pilot light [accessible in primary


location] (off-line) 215
7Q4D65, Discrete single-funct instr
[accessible in primary location] 215
7Q4D66, Discrete multi-funct instr
[accessible in primary location] 215
7Q4D70, Discrete single-funct instr
[inaccessible in primary location] (off-line)
215
7Q4D71, Discrete multi-funct instr 216
7Q4D75, [2-way] solenoid valve [field
mounted] (off-line) 216
7Q4D76, [2-way] angle solenoid valve [field
mounted] (off-line) 216
7Q4D77, 3-way solenoid valve [field
mounted] (off-line) 216
7Q4D78, 4-way single solenoid valve [field
mounted] (off-line) 216
7Q4D79, 4-way double solenoid valve [field
mounted] (off-line) 216
7Q4D80, Pilot light 216
7Q4D85, Discrete single-funct instr 217
7Q4D86, Discrete multi-funct instr 217
7Q4D88, Single port pitot tube [field
mounted] (off-line) 217
7Q4D89, Pitot-venturi tube [field mounted]
(off-line) 217
7Q4D90, Off-line averaging pitot tube [field
mounted] (off-line) 217
7Q4D92, Off-line target flow instr [field
mounted] (off-line) 217
7Q4D93, Off-line propeller flow instr [field
mounted] (off-line) 218
7Q4D94, Off-line magnetic flow instr [field
mounted] (off-line) 218
7Q4D95, Off-line ultrasonic flow instr [field
mounted] (off-line) 218
7Q4D97, Discrete single-funct instr 218
7Q4D98, Discrete multi-funct instr 218

A
Assemblies 230
Assembly Notes 432

B
Basic Information 39
Bio-Pharm Operator Symbol SOP_3 401
Bio-Pharm Operator Symbol SOP_42 402
Bio-Pharm Specialty Component Symbol
R180B 403
Bio-Pharm Specialty Component Symbol
R180S 404

717

Index
Bio-Pharm Specialty Component Symbol
VS3WD 406
Bio-Pharm Specialty Component Symbol
VS4WD 407
Bio-Pharm Specialty Component Symbol
VSCCB 405
Bio-Pharm Specialty Component Symbol
VSCCBU425 405
Bio-Pharm Specialty Component Symbol
VSDTC 405
Bio-Pharm Specialty Component Symbol
VSDTP 404
Bio-Pharm Specification Component
Symbol B45C 380
Bio-Pharm Specification Component
Symbol B45T 379
Bio-Pharm Specification Component
Symbol B45TC 379
Bio-Pharm Specification Component
Symbol B90C 378
Bio-Pharm Specification Component
Symbol B90T 376
Bio-Pharm Specification Component
Symbol B90TC 377
Bio-Pharm Specification Component
Symbol C2HD 397
Bio-Pharm Specification Component
Symbol C3HD 397
Bio-Pharm Specification Component
Symbol CA 398
Bio-Pharm Specification Component
Symbol CAPSE 373
Bio-Pharm Specification Component
Symbol CAPT 372
Bio-Pharm Specification Component
Symbol CHA 396
Bio-Pharm Specification Component
Symbol CHD 399
Bio-Pharm Specification Component
Symbol CPAN 397
Bio-Pharm Specification Component
Symbol CPHB 398
Bio-Pharm Specification Component
Symbol CSJ 398
Bio-Pharm Specification Component
Symbol FA 374
Bio-Pharm Specification Component
Symbol FAS 374
Bio-Pharm Specification Component
Symbol FERR 371
Bio-Pharm Specification Component
Symbol FERS 372

718

Bio-Pharm Specification Component


Symbol HA 373
Bio-Pharm Specification Component
Symbol MA 375
Bio-Pharm Specification Component
Symbol MAR 375
Bio-Pharm Specification Component
Symbol R180C 381
Bio-Pharm Specification Component
Symbol R180R 380
Bio-Pharm Specification Component
Symbol RCC 394
Bio-Pharm Specification Component
Symbol RCCL 394
Bio-Pharm Specification Component
Symbol RCP 393
Bio-Pharm Specification Component
Symbol REC 396
Bio-Pharm Specification Component
Symbol RECL 395
Bio-Pharm Specification Component
Symbol REP 395
Bio-Pharm Specification Component
Symbol TC 390
Bio-Pharm Specification Component
Symbol TCB 383
Bio-Pharm Specification Component
Symbol TCI 393
Bio-Pharm Specification Component
Symbol TCR 391
Bio-Pharm Specification Component
Symbol TCRSB 392
Bio-Pharm Specification Component
Symbol TCSB 392
Bio-Pharm Specification Component
Symbol TICB 386
Bio-Pharm Specification Component
Symbol TRCB 384
Bio-Pharm Specification Component
Symbol TRSCB 385
Bio-Pharm Specification Component
Symbol TSCB 385
Bio-Pharm Specification Component
Symbol TSCR 386
Bio-Pharm Specification Component
Symbol TT 381
Bio-Pharm Specification Component
Symbol TTRB 382
Bio-Pharm Specification Component
Symbol VS2D 399
Bio-Pharm Specification Component
Symbol XC 389

Plant Design System (PDS) Piping Component Data

Index
Bio-Pharm Specification Component
Symbol XT 387
Bio-Pharm Specification Component
Symbol XTRB 388
Bio-Pharmaceutical Operators 160, 401
Bio-Pharmaceutical Specialty Components
161, 403
Bio-Pharmaceutical Specification
Components 150
Bio-Pharmaceutical
SpecificationComponent Symbols 371
Bolting 566

C
Calculations From ANSI-B31.1 and
ANSI-B31.3 573
CL1010, Area Units (25) 696
CL1028, Mass Units (40) 697
CL1056, Temperature Units (15) 697
CL1064, Pressure Units (40) 698
CL1074, Density Units (35) 699
CL1100, Weld Type (100) 699
CL1162, Force Units (40) 699
CL1201, Drawing Scale (540) 700
CL1202, Drawing Size (199) 700
CL1203, Interference Manager Approval
Status (99) 700
CL1204, Interference Clash Type 700
CL1205, Interference Manager Action (10)
703
CL1207, Interference Manager Approval
Method (10) 703
CL1208, Clash Checking Option 703
CL1209, Clash Checking Volume Filter
Option 703
CL125, Fluid Code/Connector Type (999)
585
CL130, Construction Status (15) 589
CL1310, Report Source (99) 703
CL1312, Report Type (999) 703
CL1410, Design Review Type (10) 704
CL145, Materials Grade (4500) 589
CL148, Piping Materials Class Description
(31999) 625
CL160, Responsibility (25) 636
CL1605, Model Status 704
CL1610, Force Units for FrameWorks Plus
(40) 704
CL1620, Drawing View Directions (7) 705
CL1630, Drawing View Composition Status
(4) 705
CL1710, Document Source (99) 705
CL1720, Document Type (999) 706

Plant Design System (PDS) Piping Component Data

CL180, Fabrication Category (99) 636


CL190, Coating Requirements (99) 637
CL1900, Isometric Drawing Type 708
CL200, Heat Tracing Requirements (10)
637
CL2000, PD_Draw Document Type (999)
709
CL210, Heat Tracing Media (60) 638
CL220, Insulation Purpose (40) 639
CL230, Cleaning Requirements (99) 639
CL31, Object Types for Orthographic
Drawings (40) 581
CL330, CP Type/Termination/Preparation
(999) 639
CL332, Schedule / Thickness Override 643
CL340, Safety Classification (99) 645
CL35, Approval Status (10) 583
CL36, Structural Approval Status (15) 583
CL360, Stress Analysis Requirements (15)
645
CL365, Reporting Requirements (25) 645
CL366, Requirement to Reconstruct (10)
646
CL37, HVAC Approval Status (10) 584
CL380, Piping Component Type (2500)
646
CL390, Action (40) 655
CL400, Option (999) 655
CL420, Piping Component Type/Source (25)
664
CL425, Piping/Tubing Type (25) 664
CL430, Instrument Component Type/Source
(25) 664
CL499, Piping Notes (999) 664
CL50, Hold Status (10) 584
CL530, Accessory/Item Type (125) 667
CL550, Operator/Actuator Type (200) 667
CL570, Design Standard (200) 669
CL572, Wall Thickness Equation 669
CL575, Geometry Standard (31999) 669
CL576, Table Suffix/End Standard - Green
(999) 684
CL577, Table Suffix/End Standard - Red
(999) 688
CL578, Weight Code (399) 692
CL69, Equipment Divisions/Form Code (99)
584
CL990, Types of Piping Commodity Data
Forms 694
CL999, Standard Note Title (2000) 695
Codelists 577
Comments Specific to Units of Measure
Codelist Sets 580

719

Index
Commodity Code Descriptions 435
Commodity Code Matrix 435
Commodity Discussions 39
Completing Materials 441
Connect Point Data 44, 141, 165, 178, 187,
193, 203
Connect Point Data_GCP 75
Connect Point Data_Independent Variables
107
Control Valves and Regulators (7P1E) 176

D
Definition of Generic Variables 35
Definition of Specific Variables 32
Design DDL 20
Detail F1 413
Detail F2 413
Detail F4 414
Detail F7 414
Detail F8 415
Detail H1 411
Detail H2 411
Detail H3 412
Detail H4 412
Detail L1 421
Detail L2 421
Detail L4 422
Detail L7 423
Detail L8 424
Detail P1 415
Detail P2 416
Detail P3 416
Detail P4 417
Detail P5 417
Detail P7 418
Detail P8 418
Detail P9 419
Detail T 420
Detail T1 419
Detail T4 420
Detail V1 407
Detail V2 408
Detail V3 408
Detail V4 409
Detail V5 409
Detail V7 410
Detail V8 410
Details Assumed 407

F
Fire and Safety Components 442

720

Fire and Safety Piping Components, On-line


(6P4C), In-line (6Q4C) 140
Fire and Safety Symbol FS10A 314
Fire and Safety Symbol FS10B 314
Fire and Safety Symbol FS11A 315
Fire and Safety Symbol FS11B 315
Fire and Safety Symbol FS13A 316
Fire and Safety Symbol FS13B 316
Fire and Safety Symbol FS1A 313
Fire and Safety Symbol FS24A 317
Fire and Safety Symbol FS26A 317
Fire and Safety Symbol FS26B 318
Fire and Safety Symbol FS2B 313
Fire and Safety Symbol FS30A 318
Fire and Safety Symbol FS38A 319
Fire and Safety Symbol FS39A 319
Fire and Safety Symbol FS60A 320
Fire and Safety Symbol FS66A338 320
Fire and Safety Symbol T-FS10A 322
Fire and Safety Symbol T-FS11A 322
Fire and Safety Symbol T-FS13A 323
Fire and Safety Symbol T-FS1A 321
Fire and Safety Symbol T-FS2B 321
Fire and Safety Symbols 313
Flanged and Miscellaneous Fittings 436
Flanged Fittings 453
Flanges 446

G
Gaskets 559
General Comments 579
General Conventions 23

I
In-Line Bio-Pharmaceutical Components
(6Q5P) 150
In-line Piping Macrocomponents (6N8C)
230
Instrument Specialties 465
Instrument Specialty Discussions 175
Instrument Specialty Symbol I106BZ 340
Instrument Specialty Symbol I109BZ 341
Instrument Specialty Symbol I118BZ 341
Instrument Specialty Symbol I11AZ 335
Instrument Specialty Symbol I120AZ 342
Instrument Specialty Symbol I12AZ 336
Instrument Specialty Symbol I13AZ 336
Instrument Specialty Symbol I14AZ 337
Instrument Specialty Symbol I15AZ 337
Instrument Specialty Symbol I16AZ 338
Instrument Specialty Symbol I17AZ 338
Instrument Specialty Symbol I18AZ 339

Plant Design System (PDS) Piping Component Data

Index
Instrument Specialty Symbol I201AZ 342
Instrument Specialty Symbol I201BZ 343
Instrument Specialty Symbol I201CZ 343
Instrument Specialty Symbol I209AZ 344
Instrument Specialty Symbol I20AZ 339
Instrument Specialty Symbol I213AZ 344
Instrument Specialty Symbol I216AZ 345
Instrument Specialty Symbol I219AZ 345
Instrument Specialty Symbol I237AZ 346
Instrument Specialty Symbol I253AZ 346
Instrument Specialty Symbol I301AZ 347
Instrument Specialty Symbol I30AZ 340
Instrument Specialty Symbol I324CZ 347
Instrument Specialty Symbol I324DZ 348
Instrument Specialty Symbol I324EZ 348
Instrument Specialty Symbol I324FZ 349
Instrument Specialty Symbol I3AZ 333
Instrument Specialty Symbol I5AZ 333
Instrument Specialty Symbol I6AZ 334
Instrument Specialty Symbol I7AZ 334
Instrument Specialty Symbol I8AZ 335
Instrument Specialty Symbols 333
Introduction 17

L
Labor Codes 488

M
Miscellaneous 218
Miscellaneous Non-Wetted Fittings 497
Miscellaneous Symbol A1003 368
Miscellaneous Symbol A1005 368
Miscellaneous Symbol A1251 369
Miscellaneous Symbol A1331 369
Miscellaneous Symbol A1332 370
Miscellaneous Symbol OP_251 351
Miscellaneous Symbol OP_271 352
Miscellaneous Symbol OP_291 352
Miscellaneous Symbol OP_292 353
Miscellaneous Symbol OP_311 353
Miscellaneous Symbol OP_331 354
Miscellaneous Symbol OP_332 354
Miscellaneous Symbol OP_333 355
Miscellaneous Symbol OP_334 355
Miscellaneous Symbol OP_351 356
Miscellaneous Symbol OP_391 356
Miscellaneous Symbol OP_401 357
Miscellaneous Symbol OP_411 357
Miscellaneous Symbol OP_412 358
Miscellaneous Symbol OP_413 358
Miscellaneous Symbol OP_451 359
Miscellaneous Symbol OP_452 359

Plant Design System (PDS) Piping Component Data

Miscellaneous Symbol OP_453 360


Miscellaneous Symbol OP_491 360
Miscellaneous Symbol OP_492 361
Miscellaneous Symbol OP_493 361
Miscellaneous Symbol OP_494 362
Miscellaneous Symbol OP_571 362
Miscellaneous Symbol OP_572 363
Miscellaneous Symbol OP_573 363
Miscellaneous Symbol OP_574 364
Miscellaneous Symbol OP_711 364
Miscellaneous Symbol OP_731 365
Miscellaneous Symbol OP_811 365
Miscellaneous Symbol OP_851 366
Miscellaneous Symbol OP_852 366
Miscellaneous Symbol OP_853 367
Miscellaneous Symbol OP_854 367
Miscellaneous Symbol OP3 349
Miscellaneous Symbol OP4 350
Miscellaneous Symbol OP5 350
Miscellaneous Symbol OP9373 351
Miscellaneous Symbol S2003 370
Miscellaneous Symbol S3003 371
Miscellaneous Symbols 349
Miscellaneous Wetted Fittings 496
Model Graphics 19

N
Named and Unamed Specialties 165
Named and Unnamed Instruments 177
Named or Unnamed Instruments 192, 203
Named or Unnamed Relief Devices 187
Non-Database Part of Item Descriptions 19
Non-Database Part of the Piping Job
Specification 18
Non-parametric and Parametric Piping and
Tubing (PIPING, TUBING) 40

O
Off-Line Instruments (7Q4D) 201
Off-Site Piping Connectors (6R9H) 229
Off-volume Piping Connectors (6R9G) 228
On-line Fittings (6P2C) and In-line Fittings
(6Q2C) 74
On-line Fittings (6P3C) and In-line Fittings
(6Q3C) 106
On-line Piping Macrocomponents (6P8C)
230
Other in-line Instruments (7P3C) 191

P
Pipe 504

721

Index
Pipe Supports 475
Piping and Instrument Symbol Notes 425
Piping Commodity Data 39
Piping Commodity Symbol F10_1 264
Piping Commodity Symbol F10_2 265
Piping Commodity Symbol F101 283
Piping Commodity Symbol F114A 284
Piping Commodity Symbol F114B 285
Piping Commodity Symbol F114C 286
Piping Commodity Symbol F114D 287
Piping Commodity Symbol F122_1 288
Piping Commodity Symbol F122_2 289
Piping Commodity Symbol F125 290
Piping Commodity Symbol F127 291
Piping Commodity Symbol F128 292
Piping Commodity Symbol F13 266
Piping Commodity Symbol F134 293
Piping Commodity Symbol F145 294
Piping Commodity Symbol F147 295
Piping Commodity Symbol F14A 267
Piping Commodity Symbol F14B 268
Piping Commodity Symbol F150 296
Piping Commodity Symbol F152 297
Piping Commodity Symbol F154 298
Piping Commodity Symbol F160 299
Piping Commodity Symbol F163 300
Piping Commodity Symbol F170 301
Piping Commodity Symbol F172 302
Piping Commodity Symbol F173 303
Piping Commodity Symbol F176 304
Piping Commodity Symbol F177 305
Piping Commodity Symbol F178 307
Piping Commodity Symbol F179 308
Piping Commodity Symbol F17D 269
Piping Commodity Symbol F180 309
Piping Commodity Symbol F180F 306
Piping Commodity Symbol F182 310
Piping Commodity Symbol F184 311
Piping Commodity Symbol F188 312
Piping Commodity Symbol F19 270
Piping Commodity Symbol F1A 260
Piping Commodity Symbol F25 271
Piping Commodity Symbol F27 272
Piping Commodity Symbol F28 273
Piping Commodity Symbol F31 274
Piping Commodity Symbol F32 275
Piping Commodity Symbol F39 276
Piping Commodity Symbol F4 261
Piping Commodity Symbol F43_1 277
Piping Commodity Symbol F43_2 278
Piping Commodity Symbol F47 279
Piping Commodity Symbol F47A 280
Piping Commodity Symbol F6 262

722

Piping Commodity Symbol F63 281


Piping Commodity Symbol F8 263
Piping Commodity Symbol F84 282
Piping Commodity Symbol Legend 231
Piping Commodity Symbol P1 232
Piping Commodity Symbol V1 233
Piping Commodity Symbol V11 240
Piping Commodity Symbol V12 241
Piping Commodity Symbol V13 242
Piping Commodity Symbol V16 243
Piping Commodity Symbol V18 244
Piping Commodity Symbol V19 245
Piping Commodity Symbol V2 234
Piping Commodity Symbol V26 246
Piping Commodity Symbol V2A 235
Piping Commodity Symbol V2B 235
Piping Commodity Symbol V3 236
Piping Commodity Symbol V32 247
Piping Commodity Symbol V33 248
Piping Commodity Symbol V34 249
Piping Commodity Symbol V38 250
Piping Commodity Symbol V4 237
Piping Commodity Symbol V40 251
Piping Commodity Symbol V41 252
Piping Commodity Symbol V42 253
Piping Commodity Symbol V51 254
Piping Commodity Symbol V58 255
Piping Commodity Symbol V6 238
Piping Commodity Symbol V62 256
Piping Commodity Symbol V72 257
Piping Commodity Symbol V8 239
Piping Commodity Symbol V81 258
Piping Commodity Symbol V82 259
Piping Commodity Symbols 231
Piping Connectors 228
Piping Job Specification File Descriptions
17
Piping Specialty Components, On-line
(6P6C) , In-line (6Q6C) 163
Piping Specialty Symbol S11BZ 326
Piping Specialty Symbol S13AZ 327
Piping Specialty Symbol S1AC 323
Piping Specialty Symbol S1BZ 324
Piping Specialty Symbol S28AZ 327
Piping Specialty Symbol S28BZ 328
Piping Specialty Symbol S32BC 328
Piping Specialty Symbol S36AZ 329
Piping Specialty Symbol S3AZ 324
Piping Specialty Symbol S49AC 329
Piping Specialty Symbol S4AC 325
Piping Specialty Symbol S51AC 330
Piping Specialty Symbol S53AC 330
Piping Specialty Symbol S5AZ 325

Plant Design System (PDS) Piping Component Data

Index
Piping Specialty Symbol S64BC 331
Piping Specialty Symbol S70AC 331
Piping Specialty Symbol S70BC 332
Piping Specialty Symbol S78AC 332
Piping Specialty Symbol S7AZ 326
Piping Specialty Symbols 323
Piping Utility Connector (6R9E) 228
Preface PDS 15

R
Reference Data File Descriptions 17
Relief Devices (7P2C) 186

S
Seed File Definitions 20
Signal Lines (7N2A) 176
Socket Fittings 516
Socketwelded Fittings 524
SOP3, Manual bonnet (in-line)
(not-automatic) 160
SOP42, Pneumatic bonnet (in-line)
(not-automatic) 161
Steam Specialties 443
Strainer Specialties 459
Symbols 231

T
Threaded Fittings 527
Tubing and Hose 499
Tubing Fittings 518

U
Underground Fittings 532

V
Valve Operators and Actuators 219
Valves 535
Valves (6Q1C) 43
Variables Used in Symbols and Tables 32

W
Welded Fittings 551

Plant Design System (PDS) Piping Component Data

723