You are on page 1of 5

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

New Features for INSITE 8.0.0


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Note: If it is difficult to read this document with Microsoft Notepad, click on
"Word Wrap" under the "Format" menu item or 'maximize' the Notepad window. To pr
int this and have the tables in a valid format set the page margins to 0.25 and
font to Courier New.
See INSITE Release Notes for issues with the current and previous releases.
Contact the local Cummins Distributor to register your new INSITE and receive an
Activation Key for the Basic and Functional License.
The latest INSITE information can be found on the website http://insite.cummins.
com
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
New INSITE Base Features
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Installation upgrade capability
Upgrade from INSITE 7.6.0, 7.6.1, and 7.6.2.
- Support for Windows 8
INSITE 8.0.0 is now fully compatible with Windows 8.
- Product Based Licensing
INSITE 8.0.0 licensing has been updated to include licensing based on the engine
support needed. All of the existing levels of Pro, Lite and RSGR/Industrial Pr
o and Basic are supported in all of the Product Levels.
Product Levels:
1. MR/HD Automotive - This will support all Mid Range and Heavy Duty automotive
engines supported by the Service Information Rule (SIR) and Repair and Maintena
nce Information (RMI) regulations.
2. MR/HD Plus - This will support all Mid Range and Heavy Duty automotive and i
ndustrial engines including those supported by SIR and RMI. This does not inclu
de High Horsepower engines.
This will support all Mid Range and Heavy Duty automotive and i
3. Service Plus
ndustrial engines and High Horsepower engines. This functionality level will re
quire High Horsepower Certification before it can be purchased.
Note: Higher functionality levels will not function without an active Basic lic
ense.
- Cummins License Configuration Tool
A new application to manage INSITE licensing has been developed. This applicati
on is more flexible and will allow users to repair and transfer licenses without
having to go through the regional distributor. The regional distributor will s
till need to be contacted for a new INSITE license.
If no licenses are activated, INSITE will function only in Simulator Mode.
Note: An internet connection is required to activate licenses. It is also need
ed every 90 days to re-validate licenses. Re-validation will occur in the backg
round if an internet connection is present. If the computer is not connected to
the internet, INSITE will display a warning 30 days before functionality derate

to Basic occurs.
- INSITE Functionalities of RSGR and Industrial Pro
Industrial Pro and RSGR functionality has been combined into RSGR/Industrial Pro
. This will provide all RSGR/Industrial Pro users the proper functionality depe
nding on the connected engine type - automotive, industrial, or power generation
product. On automotive engines, INSITE will still restrict RSGR adjustable set
tings and on industrial or power generation engines, INSITE will function as Pro
which includes calibration download for industrial and power generation product
s.
- Reset Inactive Faults
With INSITE 7.6.2, this function was disabled for the 2007 and above engine mode
ls. To reset inactive fault codes, the Reset All Faults option can be selected.
- INSITE Integrated Simulator - Multi Module
With INSITE 7.6.2, changes were made for 2007 models and above were combined int
o one single simulator called INSITE Integrated Simulator - Single Module.
With INSITE 8.0.0, for 2007 models and above multi module simulators are now com
bined into one single simulator called INSITE Integrated Simulator - Multi Modul
e. This will display all the Features and Parameters, ECM Diagnostic Tests, and
Advanced ECM Data that is supported for multi module engines.
The existing 2007 models and above multi module engine simulators will be remove
d. This will not impact the multi module engine simulators prior to 2007 models.
- INSITE Data Packs
Installed with 8.0 is the Data Pack program. This is a base program that will a
llow minor updates to be installed without the need of an INSITE Feature Pack re
lease. This program, and the License Configuration Tool, is built into the INSIT
E installation and will install before INSITE. If they are removed after instal
lation, INSITE will not function. INSITE Data Packs may include the support of
a new engine product, new features and new monitors. These will be installed us
ing the Cummins Inc. Update Manager.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Calibration Selection and Download
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- INCAL
The INCAL expiration date has been extended from six months to seven months. Th
is change will also apply to calibrations that are downloaded from QuickServe On
line.
- Calibration Passwords
If a calibration authorization is needed during a calibration download, a Fleet
Calibration Count will be needed. Fleet Counts will be the only Calibration Aut
horization Password available with the Licensing Configuration Manager.
The single calibration password option is no longer available. The Calibration A
uthorization window will only display a check box to use a Fleet Calibration Cou
nt and display the current and requested ECM Code information.
- Programmable Datalink Device (PDD) Calibration
When selecting PDD under Calibration Selection, INSITE will disconnect from the
ECM and open the reflash window in full screen.

Once the PDD reflash has completed, the PDD window must be closed by using the C
lose Button (X) on the window.
INSITE will not automatically reconnect to the ECM after the PDD window has been
closed. A manual reconnection will be necessary.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Work Orders
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Work Orders and Images created in Simulator Mode on an earlier release, will b
e deleted on the upgrade to 8.0.0. This affects simulator only. Work Orders an
d Images created from an ECM will be retained.
When connected in Simulator Mode, only Work Orders and Images created with the I
ntegrated Simulator will be displayed.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
ECM Diagnostic Tests
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
***This will only be displayed if it is supported by the calibration.
- Aftertreatment Diesel Particulate Filter Restriction Test
This test will aid in the evaluation of the Aftertreatment Diesel Particulate Fi
lter to determine if it needs to be cleaned and if it meets reuse criteria after
a cleaning event.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Advanced ECM Data
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
***These will only be displayed if they are supported by the calibration.
- Aftertreatment Diesel Oxidation Catalyst Efficiency
Each time a regeneration is performed, the ECM calculates the efficiency of the
Diesel Oxidation Catalyst. This value is logged in the ECM when there is a chang
e from the previously calculated value. This feature will display the last ten l
og values.
- Aftertreatment Maintenance and Aftertreatment Maintenance Filter Installation
This feature has been updated to include two new monitors: Aftertreatment Diesel
Particulate Filter Remaining Hours and Aftertreatment Diesel Particulate Filter
Remaining Distance. These monitors provide the distance and hours remaining be
fore the next Diesel Particulate Filter cleaning.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Monitors
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
***These will only be displayed if they are supported by the calibration.
- Electronic Dump Valve Current
- Electronic Dump Valve Position
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Languages Supported:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- English
Limited Translation:
- Chinese (Simplified)
- Danish

Dutch
Finnish
French
German
Indonesian
Italian
Hungarian
Japanese
Korean
Norwegian
Polish
Portuguese
Romanian
Russian
Spanish
Swedish
Turkish

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Operating System Support
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Windows 7 32-bit and 64-bit
- Windows 8 32-bit and 64-bit
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Recommended PC Requirements
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
COMPONENT

REQUIREMENTS (Recommended for new hardware purchases)

Platform:

IBM or 100% Compatible

Operating System:

Windows 8 32-bit

Processor:

2.1 GHz or greater dual-core

RAM Memory:

4 GB or greater

Hard Drive:

2 GB or greater available disk space

Media Device:

Dual Layer - Double Density DVD-ROM

Display:

Minimum Resolution 1024 x 768

Keyboard:

101 Key Enhanced

Pointing Device:

Windows Compatible Device

Multimedia:
PCs that will be used for Virtual College training will
require multimedia and sound capability
Other Software:

Adobe Acrobat Reader v9.0 and later


Microsoft .NET Framework v4.0

Printer:

Windows Compatible

Internet connection:

DSL / Broadband high-speed

Available Ports:

Two USB 2.0

Other:
ation.

Refer to http://insite.cummins.com for the latest inform

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Minimum PC Requirements
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
COMPONENT

REQUIREMENTS (for minimum performance)

Platform:

IBM or 100% Compatible

Operating System:

Windows 7 32-bit
Note: Windows 7 Virtual PC and XP Mode are not support

ed
Processor:

2 GHz

RAM Memory:

2 GB

Hard Drive:

2 GB available disk space

Media Device:

DVD-ROM

Display:

Minimum Resolution 1024 x 768

Keyboard:

101 Key Enhanced

Pointing Device:

Windows Compatible Device

Multimedia:

Any Windows Compatible Sound Device

Other Software:

Adobe Acrobat Reader v9.0 and later


Microsoft .NET Framework v4.0

Printer:

Windows Compatible Device

Internet connection:

DSL / Broadband high-speed

Available Ports:
s.

See datalink adapter manufacturer for port specification

Other:
n

Refer to http://insite.cummins.com for latest informatio

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
JRE Created: INSITE 8.0.0 September 2013
Document 6733-NEWF-07 Version 1.0.0
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

You might also like