STORAGE MANAGEMENT MADE SIMPLE

WITH FIBRECAT SX

1. FIBRECAT SX MANAGER

2. STORAGE MANAGER FOR SANS

Content
Storage Management made simple with FibreCAT SX ............................... 2
Purpose............................................................................................................ 2
Terms used in this exercise ............................................................................. 3
Chapter 1: FibreCAT SX Manager................................................................. 4
Step 1-01: Create a Virtual Disk and a Volume................................................ 4
Step 1-02: Map Volume to Server.................................................................... 9
Step 1-03: Mount Volume .............................................................................. 13
Step 1-04: Operational Validation .................................................................. 26
Chapter 2: Storage Manager for SANs ....................................................... 27
Step 2-01: Extend a LUN ............................................................................... 27
Step 2-02: Operational Validation .................................................................. 31
Step 2-03: Create a new LUN ........................................................................ 32
Step 2-04: Operational Validation .................................................................. 39
Summary........................................................................................................ 40
Chapter 1: FibreCAT SX Manager

STORAGE MANAGEMENT MADE SIMPLE WITH


FIBRECAT SX

Purpose
This composition is intended to introduce students to the basic steps required to
provision FibreCAT SX storage to a Windows Server 2003 R2 server.

Chapter 1: Use the “FibreCAT SX manager” web user interface native to the
FibreCAT SX to provision disk space by:
• creating a virtual disk (also called RAID group)
• creating a volume (also called LUN)
• assigning the volume to the server.
After that, some data is written to the volume.

Chapter 2: Use Windows Server 2003 “R2”’s native “Storage Manager for
SANs” to
• extend a volume and the file system
• create a new volume and assign it to the server.
After that, some data is written to the volume.

Special Instructions:

Before you begin, please record the IP address for the server and the FibreCAT
SX storage array that you have been assigned.

Server IP address __________________________

FibreCAT SX IP address __________________________

Page 2
Storage Management with FibreCAT SX

Terms used in this exercise

Windows Server

Volume = LUN

Subsystem,
Virtual disk = e. g. FibreCAT SX
RAID group

Hard Disk Drives


Chapter 1: FibreCAT SX Manager

Chapter 1: FibreCAT SX Manager

Step 1-01: Create a Virtual Disk and a Volume


A Virtual Disk (vdisk for short) is a group of drives that are combined to a RAID
array, also known as a RAID group.
The wizard also allows you to create volumes (or LUNs) in the same step. We will
create a RAID1 virtual disk with a single 20 GB volume.
Please follow the first two steps to log on the FibreCAT SX. After that, you can try
to find your own way through the Web user interface or just follow the
instructions.

How to logon to FibreCAT SX60:

0. Open your Internet Explorer

1. Type in the IP adress of your


FibreCAT SX60 in the adressbar,
e.g.:
http:// 172.25.60.2

2. Please log in:


Username = manage
Password = !manage
Now you should see a control panel on
the left side of your screen. There are a
lot of items on this panel, but also bigger
buttons:

4. Click on the button called “Manage”

5. Go to the link called “vdisk


configuration”

6. Click on the link called “create a


vdisk”

Page 4
Storage Management with FibreCAT SX

7. Select: “Manual Virtual Disk Creation”


8. Type: “SNW-TEST1” in the field: Enter Virtual Disk Name
9. Select: “RAID 1 – Disk Mirroring” in the field: Virtual Disk RAID Level
10. Press “Create New Virtual Disk”.

11. Now you have to wait, while the


“Processing”- Screen is shown!
Chapter 1: FibreCAT SX Manager

12.. Select the first two icons (representing the hard disks) and press the button
“Continue…”

Page 6
Storage Management with FibreCAT SX

13. Select: Create Volumes of Equal Size? => NO

and press the button “Create Virtual Disk”

14. Type: “20000” in the field Volume Size for a 20 GB volume.

15. Press: Add Volumes and OK

Confirm information with OK


Chapter 1: FibreCAT SX Manager

Online Initialization is selected by default so you immediately can use the Virtual
Disk.

Page 8
Storage Management with FibreCAT SX

Step 1-02: Map Volume to Server


In the previous step, we created the virtual disk and the volume, but did not assign
it to any host. This is done in this step.

On the control panel on the left side of your screen, navigate


to the “volume mapping” menu.

1. Click on the link called “VOLUME MANAGEMENT”

2. Click on the link called “volume mapping”

3. Click on the link called “map hosts to volume”


Chapter 1: FibreCAT SX Manager

4. Please scroll down to the end of the page, to the column “Map Host or Default”

5. In the drop-down menu for Host, please select a “Host Name” for the Fibre
Channel Host Bus Adapter (HBA) of the server.
If no host name is available, select a WWN.

6. Please specify a LUN number 0 (between 0 and 127 possible)

7. Then click on “Map Host or Default”.

Page 10
Storage Management with FibreCAT SX

This screen will show the result in the “Host Mapping” column.
Chapter 1: FibreCAT SX Manager

Log off from the FibreCAT SX Manager.

Page 12
Storage Management with FibreCAT SX

Step 1-03: Mount Volume

The following steps are made on your Windows Server 2003 operating system.
1. Please login as administrator. You will need an administrative account and the
associated password. Make sure that you have full access due to administrative rights!
2. Press: START on the Windows Task Bar and Press: Programs, then Administrative
Tools
3. Press: Computer Management

This screen should appear:

4. Press: Disk Management on the left panel.


Chapter 1: FibreCAT SX Manager

Initialize and Convert a Disk

This screen should pop up:


5. Press: Next

Page 14
Storage Management with FibreCAT SX

Initialize a Disk:

6. Select: Disk 1

7. Press: Next
Chapter 1: FibreCAT SX Manager

Select the disk to convert

8. Select: Disk 1

9. Press: Next

Page 16
Storage Management with FibreCAT SX

Completing the Disk Wizard

10. Press: Finish


Chapter 1: FibreCAT SX Manager

Now you should see a new Dynamic Disk: 20 GB Unallocated

11. Click right in symbol for the new Dynamic Disk the bar and select New
Volume

The New Volume Wizard should appear.

Page 18
Storage Management with FibreCAT SX

New Volume Wizard

12. Press: Next


Chapter 1: FibreCAT SX Manager

13. Press: Next

Page 20
Storage Management with FibreCAT SX

14. Press Next


Chapter 1: FibreCAT SX Manager

15. Select: Assign the following drive letter

16. Select: An unassigned letter for the volume, for example S.

17. Press: Next

Page 22
Storage Management with FibreCAT SX

18. Select: Format this volume

19. Type: SNIA HOL to change the Volume label

20. Select: Perform a quick format

21. Press: Next

22. On the summary screen, press Finish


Chapter 1: FibreCAT SX Manager

Note: The new volume (S volume) should show a Formatting status.


23. You have to wait until the format is completed.
Note: After completion, the volume (S volume) should show a Healthy status.

Page 24
Storage Management with FibreCAT SX

Healthy status
Chapter 1: FibreCAT SX Manager

Step 1-04: Operational Validation

Putting data on the Volume

1. Copy data

• Double click on My Computer icon

• Double click on Local Disk C:

• Locate the “Data to Copy” directory

• Right click on the “Data to Copy” directory & select Copy

2. Paste data

• Double click on My Computer icon

• Locate Hard Disk Drive S: and click on it

• Right click on the SNIA HOL (S:) and select paste.

• Double click the SNIA HOL (S:) drive

3. Verify that the “Data to Copy” directory is there.

Page 26
Storage Management with FibreCAT SX

Chapter 2: Storage Manager for SANs

Step 2-01: Extend a LUN


In this exercise, we are extending the LUN we just created and assigned with the
FibreCAT SX manager by
• Starting Microsoft’s Storage manager for SANs
• Selecting the LUN we just created
• Perform Extend LUN
You can try to do this on your own or follow the detailed instructions and
screenshots below.

1. Logon to the Server


Username=Administrator
Password=snw

Verify the VDS Provider is installed


(Start –Settings – Control Panel –Add/Remove Programs)
Fujitsu Siememens Computers FibreCAT SX VDS Provider 2.0
Chapter 1: FibreCAT SX Manager

2. Launch the Storage Manager for SANs


(Start – Programs – Administrative Tools – Storage Manager for SANs)

Wait for VDS to load its drivers. This might take a while …

3. Click on Subsystems in the left panel – You should see the FibreCAT SX.

4. Click on LUN management – You should see the LUN we just created
5. Select the LUN. Click on extend LUN in the right panel

Page 28
Storage Management with FibreCAT SX

6. Specify the LUN size in the grey box


that pops up, e.g. 22 GB.

7. Click on “OK” to extend the LUN.

8. Verify that the LUN size has changed.


9. Close the SAN manager.
Chapter 1: FibreCAT SX Manager

Extend the Volume

10. Open the Disk Manager


(Start – Run – type “compmgmt.msc /s”). Browse to Storage, and Disk
Management

11. Select extend Volume


12. Click through the Wizard, using the defaults.

Page 30
Storage Management with FibreCAT SX

Step 2-02: Operational Validation

Using Diskmanager

Using the Explorer

Open the Windows Explorer and


select the S: drive. Right-click on
Properties to see the new total
capacity.
Chapter 1: FibreCAT SX Manager

Step 2-03: Create a new LUN


In this step, we are creating a new LUN and assign it to the server by
• Starting Microsoft’s Storage manager for SANs
• Perform Create LUN
You can try to do this on your own with the following hints or follow the detailed
instructions and screenshots below.

1. Logon to the Server


Username=Administrator
Password=snw

2. Launch the Storage Manager for SANs


(Start – Programs – Administrative Tools – Storage Manager for SANs)

Page 32
Storage Management with FibreCAT SX

Wait for VDS to load its drivers. This might take a while …

3. Click on Subsystems in the left panel – You should see the FibreCAT SX.
4. Click on LUN management – You should see the LUN we just created.
5. Then click on create LUN in the right panel
Chapter 1: FibreCAT SX Manager

6. Select a Subsystem and a LUN type (e.g. Mirrored)


7. Press Next.

Page 34
Storage Management with FibreCAT SX

8. On the next screen, specify the LUN name “SNW HOL2” and size “10GB”.
9. Press Next.
Chapter 1: FibreCAT SX Manager

10. Select assign the LUN now. You will see your server and the Fibre Channel HBA ports.
(The HBA WWN numbers are a unique identification of the HBA port – like a MAC address for
a Network card – and are used to map the LUN to the server)
11. Press Next.

Page 36
Storage Management with FibreCAT SX

12. Now you can format the LUN, give it a name and assign a drive letter. E.g T:\.
13. Accept the other default options with Next.
Chapter 1: FibreCAT SX Manager

14. You can review your request and press “Create LUN” to execute it.

Page 38
Storage Management with FibreCAT SX

Step 2-04: Operational Validation

Open the Windows Explorer and select the newly created drive. Right-click on
properties to verify the capacity.
As in Step 1-04, you can also copy and paste some data to it.

Open the Windows Explorer and


select the T: drive. Right-click on
Properties to see the new total
capacity.
Chapter 1: FibreCAT SX Manager

SUMMARY
You have successfully completed the provisioning of the storage-system to an
application server with the FibreCAT SX manager and with Windows Server
2003 R2’s Storage manager for SAN.

Page 40