You are on page 1of 79

RSLogix 5000 Release History

Installation Notes
Review these notes before attempting to install this version of the RSLogix 5000 software.

Prior to Installation
Keep the following considerations in mind before you install the RSLogix 5000 software:
Be certain that no copies of RSLogix 5000 are currently running.
Make sure that you have Administrator privileges (for your Windows NT V4.0 or Windows 2000 or Windows XP operating system) on the machine on which you
want to install the software. You will not be able to complete the installation without these privileges.
Close all other applications before running the setup process.
If you want to perform online communications, you must install RSLinx in addition to RSLogix 5000.

Installing the Software


The following section describes installing RSLogix 5000 software.
1.

Start the PC.

2.

Start the Windows operating system, if it does not start automatically.

3.

Insert the RSLogix 5000 installation CD into your CD-ROM drive.


The CD-ROM should autostart. If it does not autostart, run ausetup.exe from the root of the CD.

4.

Select Install RSLogix 5000.


Note: If you already have a version of RSLogix 5000 installed on your computer and you are running Windows NT, you will need to manually uninstall the older
version. If you are running Windows 2000 or Windows XP, you may leave the older version installed on your system.

5.

Follow the directions that appear on your screen.


When prompted for a serial number, enter any sequence of characters, not longer than 10 characters. Use the F1 key if you need help.

6.

When prompted, click Yes to complete the activation of the software.


Follow the directions that appear on your screen.

7.

Click on Finish to complete the installation.


When the setup utility finishes, an entry for the RSLogix 5000 application program appears in the program list in the Rockwell Software group.

8.

Remove the CD of the RSLogix 5000 installation from the CD-ROM drive and store it in a safe place.

Starting RSLogix 5000 software


To start RSLogix 5000 software, click Start and then select Programs > Rockwell Software > RSLogix 5000 Enterprise Series > RSLogix 5000 from the menu. (Note
that if you are installing Version 9.0 or earlier, the path is Programs > Rockwell Software > RSLogix 5000 > RSLogix 5000.)
If RSLogix 5000 does not start up or run properly, keep the following in mind:
Do you have the correct version of RSLinx software installed? RSLinx software provides communication between the controller and your personal computer.
Does your computer have enough memory? Running RSLogix 5000 requires a minimum of 64 Mb of RAM.
Is the activation key installed?

Tip
Remember to use the Help function from within the application if you need help with a specific dialog or function. Press [F1] or click the Help button on a dialog, or
select Help from the menu bar.

Uninstalling the Software


To uninstall the software, do the following:
1.

Choose Start > Settings > Control Panel.

2.

Double click on Add/Remove Programs.

3.

From the Add/Remove dialog, select RSLogix 5000-<version> and click OK.
You will be prompted to decide whether you wish to preserve any configuration data you have previously used.
Follow the prompts of the uninstaller, and RSLogix 5000 will be uninstalled from your computer.

System Requirements
To use RSLogix 5000 software effectively, your personal computer must meet the following hardware and software requirements.

Hardware Requirements
The personal computer must meet these minimum requirements; using a computer meeting these recommendations will improve performance.
Characteristic
Processor
Speed
RAM Memory
Hard Disk Space
Video
Pointing Device

Minimum Required
Recommended
Pentium II
Pentium 3 or better
450 MHz
733 MHz
128 Mbytes
256 Mbytes
150 Mbytes free
300 Mbytes free
800 x 600 pixels, 256 colors
1024 x 768 pixels, True Color
Any Windows-compatible pointing device

Software Requirements
You must have installed these software products:
The operating system must any of these:
Microsoft Windows XP Professional with Service Pack 1 or XP Home, or
Microsoft Windows 2000 Professional with Service Pack 1, 2, 3, or 4, or
Microsoft Windows NT Workstation Version 4.0, with Service Pack 5 or Service Pack 6a.
RSLogix 5000 software does not support Windows NT 3.51, Windows NT 3.50, Windows ME, Windows 98SE, Windows 98, Windows 95, or Windows 3.x
operating systems.
RSLinx communication software is not required to install RSLogix 5000. Note, however, that it IS required in order to perform online communication with
controllers.
Microsoft .NET Framework Version 1.1 must be installed on the same computer on which the RSLogix 5000 software will be installed, for version V12.00 and later.
This software is included as part of the RSLogix 5000 installation.

Revision Information
Before performing this upgrade, note that Logix5000 controllers and ControlLogix Motion modules in your system must contain a revision of firmware that is
compatible with this version of RSLogix 5000. However, previous revisions of network and I/O modules can operate in your system with the new controller firmware
contained in this release. Additionally, other software tools such as RSNetWorx for ControlNet and RSLinx have been tested to ensure compatibility with this version
of software. Because of this, we recommend that you use the most current versions of these tools. The following tables list the most recent revisions of software and
firmware that have been tested and validated together.

Software
RSLogix 5000 Version

RSLinx Version

RSNetWorx for
ControlNet Version

RSNetWorx for
DeviceNet Version

RSNetWorx for
EtherNet/IP Version

V13.00.00

2.42.00 (Build 18)

4.21.00 (Build 50)

4.21.00 (Build 50)

4.21.00 (Build 50) *

V12.03.00/V12.02.00/
V12.01.00/V12.00.00
V11.13.00/V11.12.00/
V11.11.00/V11.10.00
V10.04.00/V10.03.00/
V10.02.00/V10.00.00
V9.00.00

2.41.00 (Build 10)

4.11.00 (Build 47)

4.12.00 (Build 01)

4.11.00 (Build 29)

2.40.00 (Build 16)

3.23.00 (Build 11)

3.21.00 (Build 27)

Not applicable

2.30.02 (Build 79)

3.23.00 (Build 11)

3.21.00 (Build 27)

Not applicable

2.30.01 (Build 48)


2.30.01 (Build 48)

3.00.02 (Build 11)


[3.00 Service Pack 2]
3.00.02 (Build 11)
[3.00 Service Pack 2]

Not applicable

8.52.00

3.00.02 (Build 5)
[3.00 Service Pack 2]
3.00.02 (Build 5)
[3.00 Service Pack 2]

V8.02.00

2.30.00 (Build 47)

3.00.00 (Build 27) 1

3.00.00 (Build 19) 2

Not applicable
(included in RSLinx)

V8.00.00

2.30.00 (Build 40)

3.00.00 (Build 27)

3.00.00 (Build 19)

Not applicable
(included in RSLinx)

V7.02.00

2.20.02 (Build 126)

3.00.00 (Build 27)

3.00.00 (Build 19)

Not applicable
(included in RSLinx)

V7.00.00

2.20.02 (Build 126)

3.00.00 (Build 18)

2.22.18.0

Not applicable
(included in RSLinx)

V6.01.00

2.20.01 (Build 119)

2.25.12.0

2.22.18.0

Not applicable
(included in RSLinx)

V2.51.00

2.10.175.0

2.22.18.0

2.11.51.0

1.91

V2.50.00

2.10.175.0

2.21.21.0

2.11.51.0

1.91

V2.27.00

2.10.167.0

1.80.38.0

2.11.51.0

1.91

V2.25.00

2.10.162.0

1.80.38.0

2.11.51.0

1.91

V2.15.00

2.10.118.0

1.08.36.0

2.00.73.0

1.9

Not applicable

Note: You can download Service Packs from http://support.automation.rockwell.com.


* RSNetWorx for EtherNet/IP Version 5.00 is required for the Data Integration feature in RSLogix 5000.

Hardware
RSLogix 5000 Version
V13.00.00

V12.03.00
V12.02.00/
V12.01.00/
V12.00.00

V11.13.00
V11.12.00/
V11.11.00/
V11.10.00

V10.04.00
V10.03.00
V10.02.00/
V10.00.00

V7.00.00

V6.01.00/
V6.20.00

V2.51.00

L1 - Series A,
L1 Not applicable Version 7.11
L53 - Series A,
L53 Not applicable Version 7.7
L55 - Series A, L55 - Series A,
Version 8.16 Version 7.9

L1 - Series A,
Version 7.10

L1 - Series A,
Version 6.20

L1 - Series A,
Version 5.16

Not applicable Series A,


Version 7.9

Series A,
Version 7.8

V9.00.00

V8.52.00

V8.02.00

V8.00.00

L1 - Series A,
Version 9.13
L53 - Series A,
Version 9.13
L55 - Series A,
Version 9.14

L1 - Series A,
Version 8.20
L53 - Series A,
Version 8.14
L55 - Series A,
Version 8.78

L1 - Series A,
Version 8.20
L53 - Series A,
Version 8.14
L55 - Series A,
Version 8.20

Series A,
Version 8.12

V7.02.00

Controllers
ControlLogix
1756-L1, -L53, L55, L61, -L62,
and -L63

L1 Series A, L1 Series A, L1 Series A, L1 - Series A,


Version 13.27 Version 12.29 Version 11.35 Version 10.24
L53 - Series A,
L55 Series A, L55 Series A, L53 Series A,
Version 10.24
Version 13.27 Version 12.25 Version 11.28
L55 - Series A,
L61 Series A, L61 Series A, L55 Series A, Version 10.27
Version 13.28 Version 12.32 Version 11.32 L63 - Series A,
L62 Series A L62 Series A L63 Series A, Version 10.32
Version 13.28 Version 12.32 Version 11.26

L53 - Series A, L53 - Series A,


Version 7.6
Version 6.11
L55 - Series A, L55 - Series A,
Version 7.8
Version 6.8

L63 Series A, L63 Series A,


Version 13.28 Version 12.32
L60M03SE Series A,
Version13.5
FlexLogix 1794L33 and -L34

L33 Series A, L33 Series A, L34 Series B, Series A,


Version 13.27 Version 12.24 Version 11.25 Version 10.16
L34 Series A,
L34 Series B, L34 Series B,
Version 11.25
Version 13.27 Version 12.24
L33 Series A,
L34 Series A, L34 Series A, Version 11.25
Version 13.27 Version 12.24

CompactLogix
1769-L20, -L30, L35E

L20 Series A, L20 Series A, L20 Series A,


Version 13.17 Version 12.16 Version 11.27
L30 Series A,
L30 Series A, L30 Series A,
Version 11.27
Version 13.17 Version 12.16
L31 - Series A, L35E - Series
Version 13.18 A, Version
12.28
L32E - Series
A, Vers 13.18
L35CR - Series
A, Vers 13.18
L35E - Series
A, Vers 13.18

Not applicable Series A,


Version 8.12

L20 - Series A, Not applicable


Version 10.13
L30 - Series A,
Version 10.13

L20 Series A,
Version 8.14
L30 Series A,
Version 8.14

Series A,
Version 6.23

Not applicable

L20 - Series A, Not applicable L20 Series A, L20 Series A, Not applicable Not applicable
Version 7.17 Version 7.9
Version 8.14
L30 - Series A,
Version 8.14

RSLogix 5000 Version

DriveLogix5720
PowerFlex 700S
DriveLogix5730
PowerFlex 700S 2
SoftLogix 1789L60

V11.13.00
V11.12.00/
V11.11.00/
V11.10.00

V10.04.00
V10.03.00
V10.02.00/
V10.00.00

V9.00.00

V8.52.00

V8.02.00

V8.00.00

V7.02.00

V7.00.00

V6.01.00/
V6.20.00

V2.51.00

V13.00.00

V12.03.00
V12.02.00/
V12.01.00/
V12.00.00

Series A,
Version 13.10
Series A,
Version 13.10
Series A,
Version 13.00

Series A,
Series A,
L30 - Series A, Not applicable Series A,
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Version 12.17 Version 11.23 Version 10.16
Version 8.14
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Series A,
Version 12.02

Series A,
Version 11.11

Series A,
Version 10.02

Not applicable Series A,


Version 8.02

Series A,
Version 8.02

Not applicable Series A,


Version 7.02

Not applicable Series A,


Version 6.00

Not applicable

* Requires
RSLogix 5000
V6.03.00
RSLogix Emulate
5000

Version 13.00

Version 12.02

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Communications Modules
1734-ACNR

Series A,
Version 1.77

Series A,
Version 1.75

1734-AENT

Series A,
Version 1.030

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

1756-CNB,
-CNBR

Series D,
Version 5.38,

Series D,
Version 5.36,

Series B,
Version 2.27,

Series B,
Version 2.27,

Series A,
Version 1.19

Series A,
Version 1.19

Series C,
Version 5.3

Series C,
Version 5.3

Series B,
Version 2.21
Series A,
Version 4.005

Series B,
Version 2.21
Series A,
Version 4.002

Series A,
Version 2.3
Series B,
Version 2.7
Series A,
Version 1.18
Series A,
Version1.2
Series A,
Version 1.1

Series A,
Version 1.61
Series B,
Version 2.7
Series A,
Version 1.18
Series A,
Version1.1
Series A,
Version 1.1

1756-DHRIO

1756-DNB

1756-ENBT
1756-ENET

1756-EWEB
1757-FFLD

Series D,
Version 5.22,

Series D,
Version 5.22,

Series D,
Version 5.21,

Series B,
Version 2.27,

Series B,
Version 2.27,

Series B,
Version 2.24,

Series A,
Version 1.19

Series D,
Version 5.22,
Series B,
Version 2.27,
Series A,
Version 1.19

Series A,
Version 1.19

Series A,
Version 1.19

Series A,
Version 1.19

Series B,
Version 2.21

Series B,
Version 2.19

Series B,
Version 2.19

Series B,
Version 2.19

Series B,
Version 2.17

Series B,
Version 2.17

Series A,
Version 3.007
or 2.008
Not applicable

Series A,
Version 3.007
or 2.008
Not applicable

Series A,
Version 3.005
or 2.008

Series A,
Version 3.005
or 2.008
Not applicable Not applicable

Series A,
Version 3.005
or 2.008

Series A,
Version 3.003
or 2.008

Series A,
Version 3.003
or 2.008

Series B,
Version 2.6,
Series A,
Version 1.18
Not applicable

Series B,
Version 2.6
Series A,
Version 1.18
Not applicable

Series B,
Version 2.6

Series B,
Version 2.6
Series A,
Series A,
Version 1.18 Version 1.18
Not applicable Not applicable

Series B,
Version 2.6

Series D,
Version 5.31,
Series B,
Version 2.27,
Series A,
Version 1.19

Series D,
Version 5.27,
Series B,
Version 2.27,
Series A,
Version 1.19

Series D,
Version 5.22,
Series B,
Version 2.27,
Series A,
Version 1.19

Series D,
Version 5.27,
Series B,
Version 2.27,
Series A,
Version 1.19

Series D,
Version 5.22,
Series B,
Version 2.27,
Series A,
Version 1.19

Series D,
Version 5.22,

Series C,
Version 5.3
Series B,
Version 2.21

Series B,
Version 2.21

Series B,
Version 2.21

Series B,
Version 2.21

Series A,
Version 3.007
or 2.008
Not applicable
Series B,
Version 2.6
Series A,
Version 1.18
Not applicable

Series A,
Version 3.010

Series A,
Version 3.010
or 2.008
Series A,
Series A,
Version 1.46 Version 1.30
Series B,
Series B,
Version 2.6
Version 2.7,
Series A,
Series A,
Version 1.18 Version 1.18
Not applicable Not applicable

Series B,
Version 2.27,

Not applicable Not applicable Not applicable


Series A,
Version 1.18

Series A,
Version 1.18

Series A,
Version 1.18
Not applicable Not applicable Not applicable

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Communications Modules (continued)


1769-SDN

Series B,
Version 2.1
1788-CN2DN
Series A,
Version 1.023
1788-CNC,
Series A,
-CNCR
Version 1.5.6
1788-CNF, -CNFR Series A,
Version 1.5.6
1788-DNBO
Series A,
Version 2.002
1788-ENBT
Series A,
Version 1.28
1794-ACN15,
Series A,
-ACNR15
Version 4.2
1794-AENT
Series A,
Version 2.12
56AMXN
Series B,
Version 2.1

Series B,
Version 2.1
Series A,
Version 1.021
Series A,
Version 1.5.6
Series A,
Version 1.5.6
Series A,
Version 2.002
Series A,
Version 1.28
Series A,
Version 4.2
Series A,
Version 2.08
Series B,
Version 2.1

Series B,
Series A,
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Version 2.1
Version 1.1
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Series A,
Version 13.2
Series A,
Version 13.8
Series A,
Version 13.6
Series A,
Version 13.7
Series B,
Version 13.7
Series A,
Version 13.7
Series A,
Version 13.7
Series A,
Version 13.2
Series A,
Version 13.6

Series A,
Version 12.10
Series A,
Version 12.8
Not applicable

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Series B,
Version 12.6
Series A,
Version 12.6
Series A,
Version 12.6
Series A,
Version 12.1
Series A,
Version 12.1

Series B,
Version 11.7
Series A,
Version 11.7
Series A,
Version 11.7
Series A,
Version 5.4
Not applicable

Series A,
Version 2.10

Version 1.80

Version 1.069

Version 1.060

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Version 1.40

Version 1.33

Version 1.32

Version 1.21

Version 3.80
Version 1.80

Version 3.069
Version 1.069

Version 3.064
Version 1.060

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Version 1.047 Version 1.041 Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Series A,
Version 1.4.1
Series A,
Version 1.4.1
Series A,
Version 1.002
Series A,
Version 1.28
Series A,
Version 4.1
Series A,
Version 1.90
Series B,
Version 1.2

Series A,
Version 1.4.1
Series A,
Version 1.4.1
Series A,
Version 1.002
Not applicable

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Series A,
Version 4.1
Series A,
Version 1.90
Not applicable

Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Series A,
Version 3.6
Series A,
Version 1.90
Not applicable

Motion Modules
1756-HYD02
1756-M02AE
1756-M02AS
1756-M03SE
1756-M08SE

1756-M16SE
1784-PM02AE
1784-PM16SE

Series A,
Series A,
Series A,
Series A,
Series A,
Series A,
Not applicable Not applicable Not applicable
Version 5.5
Version 5.2
Version 5.2
Version 3.10 Version 3.10
Version 3.8
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Series A,
Version 2.9

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Series A,
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
Version 5.3
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

SERCOS Drives
Kinetix6000
(2094 Series)
Ultra3000
(2098 Series)
8720MC Series
1394C Series

Version 1.14

Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable

Firmware
Note that most of the modules supported by RSLogix 5000 utilize Flash-ROM for the storage of firmware. If you possess a module that requires a firmware change,
the ControlFLASH software tool can be used to perform an update to this Flash-ROM. This software tool and the firmware images for most of the supported
modules are contained on a CD-ROM or floppy diskettes shipped with RSLogix 5000. Starting with RSLogix 5000 V10.00.00, you can access the ControlFLASH tool
from within RSLogix 5000 (from the Tools menu), or you can automatically update your firmware as part of the project download process.
For additional information and assistance in performing a Flash-ROM update, please review the ControlFLASH manual.
In addition, Rockwell Software Technical Support has created a web site from which you can download firmware images for ControlLogix products. Go to
http://support.rockwellautomation.com/ControlFlash/ for a matrix detailing the versions of firmware that were released with each of the versions of RSLogix 5000
software, and to download the ControlFlash firmware kits and release note documents. Note that you will need your RSLogix 5000 serial number to complete the
download.

Electronic Data Sheets


The version of RSLinx provided with this version of RSLogix 5000 includes an updated set of Electronic Data Sheets (EDS) files for Rockwell Automation products.
Installing this software ensures that RSLinx and RSNetWorx will be able to work with the new versions of firmware. These EDS files are also available separately by
contacting Technical Support (phone 440-646-5800), or via the Internet (http://www.ab.com/networks/eds/). You can install them using the EDS Hardware
Installation Tool, located in the RSLinx folder in the Windows Start menu.

Choosing Your RSLogix 5000 Package


RSLogix 5000 is a scalable software solution, used to program and configure any of the Logix5000 family of controller products. Depending on the functionality you
require, you might need one or more product catalog numbers to acquire the appropriate software functionality.
The following table will help you to determine which RSLogix 5000 package is best suited for your application needs.
RSLogix 5000 Enterprise
Series Bundle

Professional Edition

Full Edition

Standard/Network
Edition

Standard Edition

Lite Edition

Mini Edition

Service Edition***

Catalog Number

9324-RLD700NXyyE*

9324-RLD600yyE*

9324-RLD300NXyyE*

9324-RLD300yyE*

9324-RLD250yyE*

9324-RLD200yyE*

9324-RLD000yyE*

Controllers Supported

CompactLogix5300
FlexLogix5400
ControlLogix5500
DriveLogix5700
SoftLogix5800

CompactLogix5300
FlexLogix5400
ControlLogix5500
DriveLogix5700
SoftLogix5800

CompactLogix5300
FlexLogix5400
ControlLogix5500
DriveLogix5700
SoftLogix5800

CompactLogix5300
FlexLogix5400
ControlLogix5500
DriveLogix5700
SoftLogix5800

CompactLogix5300
FlexLogix5400

CompactLogix5300
FlexLogix5400

CompactLogix5300
FlexLogix5400
ControlLogix5500
DriveLogix5700
SoftLogix5800

Ladder Diagram (LD)

Fully Supported

Fully Supported

Fully Supported

Fully Supported

Fully Supported

Fully Supported

Upload/Download Inc.
View Only

Function Block Diagram


(FBD) and Advanced Process
and Drive control blocks
(9324-RLDFBDyyE*, or via
9324-RLDMLPE)

Fully Supported

Fully Supported

Upload/Download Inc.
Editor Available
Separately

Upload/Download Inc.
Editor Available
Separately

Fully Supported

Upload/Download Inc.
Editor Available
Separately

Upload/Download Inc.
View Only

FBD PIDE Autotune (requires


FBD option)
(9323-ATUNEyyE*)

Included

Available Separately

Available Separately

Available Separately

Available Separately

Available Separately

Available Separately

Sequential Function Chart


(SFC)
(9324-RLDSFCE, or via 9324RLDMLPE)

Fully Supported

Fully Supported

Upload/Download Inc.
Editor Available
Separately

Upload/Download Inc.
Editor Available
Separately

Fully Supported

Upload/Download Inc.
Editor Available
Separately

Upload/Download Inc.
View Only

Structured Text (ST)


(9324-RLDSTXE, or via 9324RLDMLPE)

Fully Supported

Fully Supported

Upload/Download Inc.
Editor Available
Separately

Upload/Download Inc.
Editor Available
Separately

Fully Supported

Upload/Download Inc.
Editor Available
Separately

Upload/Download Inc.
View Only

- Highly integrated Motion


- Graphical Trending
- RSMACC Audit Support

Fully Supported
Fully Supported
Available Separately

Fully Supported
Fully Supported
N/A

Fully Supported
Fully Supported
N/A

Fully Supported
Fully Supported
N/A

Upload/Download Inc.
N/A
N/A

Upload/Download Inc.
N/A
N/A

Upload/Download Inc.
Fully Supported
N/A

DriveExecutive Lite (93034DTE01ENE)

Included

Included

Included

Included

Available Separately

Available Separately

Available Separately

RSLogix Emulate 5000 - PCbased Logix5000 controller


emulator
(9310-WED200ENE)

Included

Available Separately

Available Separately

Available Separately

Available Separately

Available Separately

N/A

RSTestStand - PC-based
operator console simulation
(9310-TSTNDENE)

Lite Included

Available Separately

Available Separately

Available Separately

Available Separately

Available Separately

Available Separately

RSLinx

Professional
Included**

Lite Included

Lite Included

Lite Included

Lite Included

Lite Included

Lite Included

Miscellaneous Features:

RSLogix 5000 Enterprise


Series Bundle

Professional Edition

Full Edition

Standard/Network
Edition

Standard Edition

Lite Edition

Mini Edition

Service Edition***

RSNetWorx for ControlNet,


DeviceNet, EtherNet/IP (9357CNETL3, 9357-DNETL3, 9357ENETL3 individually, or 9357ANETL3 combined)

Included

Available Separately

Included

Available Separately

Available Separately

Available Separately

Available Separately

- Logix CPU Security Tool

Included

Included

Included

Included

Included

Included

Included

- Routine Source Protection

Included

Included

Included

Included

Included

Included

Included

- RSMACC Authenticate (Sec.


Server) Client

Included

Included

Included

Included

Included

Included

Included

- Standalone Security Server


Explorer

Included

Included

Included

Included

Included

Included

Included

- Electronic manuals (PDF)

Included

Included

Included

Included

Included

Included

Included

- Tutorial/Quick Tour

Included

Included

Included

Included

Included

Included

Included

- ControlFLASH with Firmware

Included

Included

Included

Included

Included

Included

Included

- FBD ActiveX Faceplates

Included

Included

Included

Included

Included

Included

Included

- PLC-5/SLC-500 Translation

Included

Included

Included

Included

Included

Included

Included

- Tag Data Upload/Download


Tool

Included

Included

Included

Included

Included

Included

Included

- RSLogix 5000 Compare Tool

Included

Included

Included

Included

Included

Included

Included

- Tag Custom Data Monitor Tool

Included

Included

Included

Included

Included

Included

Included

- DeviceNet Node
Commissioning Tool

Included

Included

Included

Included

Included

Included

Included

- RSView Demo (50 Tags/2


Hour Limit)

Included

Available Separately

Available Separately

Available Separately

Available Separately

Available Separately

Available Separately

Upgrades

N/A

Full to Professional
9324-RLD6U7yyE*

Standard to
Professional
9324-RLD3U7yyE*

Standard to
Professional
9324-RLD3U7yyE*

Lite to Full
9324-RLD25U6yyE*

Mini to Standard
9324-RLD2U3yyE*

Service to Standard
9324-RLD0U3yyE*

Multi-Language Pack
(9324-RLDMLPE)
extends Standard to
match Full.

Multi-Language Pack
(9324-RLDMLPE)
extends Standard to
match Full.

Lite to Professional
9324-RLD25U7yyE*

Mini to Full
9324-RLD2U6yyE*

Service to Full
9324-RLD0U6yyE*

Mini to Professional
9324-RLD2U7yyE*

Service to
Professional
9324-RLD0U7yyE*

Miscellaneous Files & Tools:

* Replace yy with the appropriate language code where: DE = German, EN = English, ES = Spanish, FR = French, IT = Italian, PT = Portuguese.
** The RSLogix 5000 Professional Activation must be installed on the personal computer hard disk in order to activate RSLinx Professional.
***Service Edition requires controller firmware at revision 12 or above.

New Features
The following features were added to the specified releases of RSLogix 5000. Refer to the Release Notes that accompany each individual version for more detailed
information on a particular feature.

Version 13.00.00
The following new features and functionality have been added to this release of RSLogix 5000:
Sequential Function Chart (SFC) and Structured Text (ST) Online Editing
Ladder Diagram (LD) Partial Import/Export
Logic Browser (Advanced Diagnostics)
Offline Memory Estimation
ControlLogix5560M03SE Controller with Built-In SERCOS Motion Support
ControlLogix Redundancy Support
CompactLogix5331, CompactLogix5332E, and CompactLogix5335CR Controller Support
DriveLogix5730 Controller Support
Structure Description Pass-Through/Concatenation
Instruction Defaults for LD and ST Languages
Inline Verification for ST Routines
Custom Tools Menu and Toolbar
RSNetWorx for EtherNet/IP Data Integration
Motion Module Firmware Updates via AutoFlash
Motion Calculate Slave Value (MCSV)
Support for 2-Axis Analog/SSI Servo Motion Module (1756-M02AS)
Support for 3-Axis SERCOS Interface Module (1756-M03SE
Third Party Vendor Sample Projects
Additional Kinetix6000 Drives Supported
Module Support (Catalog Numbers 1734, 1738, 1756, 1784, 1788, and Miscellaneous)

Version 12.03.00/12.02.00/Version 12.01.00/Version 12.00.00


RSLogix 5000 Enterprise Series (Multiple Revision Support Phase III)
New Task Type: Event Task
Multi-Axis Coordinated Motion (Linear and Circular Interpolation)
RSNetWorx for ControlNet Offline Scheduling
Trending Improvements
SoftLogix5800 Support for SFC/ST Programming Languages
SoftLogix5800 Support for SERCOS Module, 1784-PM16SE
ControlLogix5561 and ControlLogix5562 Controller Support
CompactLogix5335E Controller Support
RSLogix Emulate 5000
Converting Projects Between Logix5000 Platforms
Support for Hydraulic Motion Module, 1756-HYD02
DriveLogix Support for Motion
Third Party Vendor Sample Projects
RSLogix 5000 Compare Tool
Module Support (Catalog Numbers 1734, 1756, 1757, 1769, 1784, 1788, and Miscellaneous)

Version 11.13.00/Version 11.12.00/Version 11.11.00/Version 11.10.00


RSLogix 5000 Enterprise Series (Multiple Revision Support Phase II)
Sequential Function Chart Language and Editor
Structured Text Language and Editor
Function Block Diagram Online Editing
SoftLogix5800 Support for FBD Language and Editor Including Online Editing
SoftLogix5800 Messaging Over EtherNet/IP
Point I/O Support
Motion Direct Commands
Integrated Source Protection with View Routine Option
RSMACC Ladder Diagram Change Auditing
ControlLogix5563 Nonvolatile Memory Support with CompactFlash
ControlLogix Redundancy Support
New Major Revision for SynchLink Interface (1756-SYNCH)

New FlexLogix Features and I/O Support


SERCOS Drive Support with 1756-M16SE Module
Additional PowerFlex and SCANPort Drives Supported
Module Support (Catalog Numbers 1734, 1756, 1769, 1788, and 1794)

Version 10.04.00/Version 10.03.00/Version 10.02.00/Version 10.00.00


RSLogix 5000 Enterprise Series (Multiple Revision Support)
Controller Firmware Updates from RSLogix 5000
RSI Security Server Password Protection
Function Block Diagram Subroutine Support
Function Block Diagram Enhanced PID Autotuning
ControlLogix5563 Controller Support
New ControlLogix5555 Models
Nonvolatile Memory for Additional Controllers
Instruction Set Enhancements: ASCII String Extensions
FLEX I/O Rail CIP Messaging
SERCOS Drive Support with 1756-M08SE Module
Module Support (Catalog Numbers 1756, 1769, 1794, and Others)

Version 9.00.00
SERCOS Drive Support with 1756-M08SE Module
Module Support (Catalog Number 1756)

Version 8.52.00
ControlLogix Redundancy
Module Support (Catalog Number 1757)

Version 8.02.00
Extended EtherNet/IP Capabilities
CompactLogix Enhancements
Motion Output CAM
The ControlLogix5555 nonvolatile memory.
DriveLogix Support

SynchLink Fiber Optic Communication Link


Instruction Set Enhancements - ASCII String Comparison and Conversion
Array SIZE Instruction
DH485 Protocol on Logix5000 Serial Port
Module Support (Catalog Number 1756, 1794, and others)

Version 8.00.00
Extended EtherNet/IP Capabilities
CompactLogix Enhancements
Motion Output CAM
ControlLogix5555 Nonvolatile Storage (NVS)
DriveLogix Support
Instruction Set Enhancements - ASCII String Comparison and Conversion
Array SIZE Instruction
DH485 Messaging Protocol on Logix5000 Serial Port
Module Support (Catalog Number 1756 and 1794)

Version 7.02.00
Windows 2000 Compatibility
CompactLogix Support
FlexLogix Support for Function Block Diagram Programming
EtherNet/IP Support
Source Protection for Routines
Synchronous Copy File Instruction
Module Support (Catalog Numbers 1756 and 1794)

Version 7.00.00
Windows 2000 Compatibility
CompactLogix Support
FlexLogix Support for Function Block Diagram Programming
EtherNet/IP Support
Source Protection for Routines
Synchronous Copy File Instruction

Module Support (Catalog Numbers 1756 and 1794)

V6.03.00
Function Block Diagram Editor
FlexLogix Support
SoftLogix Support
FLEX EX Module Support (Catalog Number 1797)
Activation Keyed Functionality

Version 6.01.00
Function Block Diagram Editor
FlexLogix Support
SoftLogix Support
FLEX EX Module Support (Catalog Number 1797)
Activation Keyed Functionality

Version 6.00.00
Function Block Diagram Editor
FlexLogix Support
SoftLogix Support
FLEX EX Module Support (Catalog Number 1797)
Activation Keyed Functionality

Version 5.02.00
SERCOS Drive support with 1756-M08SE
Quick View Pane Functionality
Function Block Diagram Editor
FLEX EX Module Support (Catalog Number 1797)
Activation Keyed Functionality

Version 2.51.00
Multi-Workstation Online Support
Instruction Set Enhancements - ASCII Serial Port and Display Style (Radix)

1756-PLS/B Module
Additional 1794 FLEX I/O Module Support
1771 Digital I/O Support Over ControlNet

Version 2.50.00
Multi-Workstation Online Support
Instruction Set Enhancements - ASCII Serial Port and Display Style (Radix)
1756-PLS/B Module
Additional 1794 FLEX I/O Module Support
1771 Digital I/O Support Over ControlNet

Version 2.27.00
Basic Trending
Position and Time Camming
Virtual and Consumed Axes
1794 FLEX I/O Module Support
RSWho Interface
Go To Navigation in the Tag Editor/Data Monitor
ControlLogix Instruction Manuals Online
Instruction Set Enhancements
Additional 1756 and ControlNet Modules Support

Version 2.25.00
Basic Trending
Position and Time Camming
Virtual and Consumed Axes
1794 FLEX I/O Module Support
RSWho Interface
Go To Navigation in the Tag Editor/Data Monitor
ControlLogix Instruction Manuals Online
Instruction Set Enhancements
Additional 1756 and ControlNet Modules Support

Version 1.20.00
Accessing the Logix5550 controller's wall clock date and time
Cross reference interface extensions
Unsolicited messaging to RSLinx
Motion instruction documentation improvement
Support for drives on ControlNet
Processor upload modification
RSLinx Version 2.0 support

Enhancements
The following enhancements were made in the specified releases of RSLogix 5000. Refer to the Release Notes that accompany an individual version for more detailed
information on a particular feature.

Version 13.00.00
Report Enhancements
Controller Type Conversion on Download
One-click Finalize Online Edits
CSV Export/Import of Rung Comments
Structured Text Argument List Dialogs
Trend Export/Import and Copy/Paste
Configurable Quick Watch Tag List
Fixed Width Tag Description Display
DeviceNet AutoScan
Automatic Project Backup
Auxiliary Feedback Support for Kinetix6000 Drives
Task and Program Inhibited Icons
Word Wrap for Text Boxes
Browse capability via SERCOS Ring to Rockwell Automation SERCOS Drives

Version 12.03.00/12.02.00/Version 12.01.00/Version 12.00.00


Report Enhancements
Function Block Diagram (FBD) Text Boxes
Linear and Custom Motor Support
Minimum Task Period Reduced
Default System Overhead Time Slice
Default Value Of The Requested Packet Interval (RPI)
Change Module RPI Online In Run Mode
Duplicate Destructive Bit Detection
Structure Array Values Maintained on User-Defined Type Change
RSMACC Detailed FBD/SFC/ST Auditing

User-Defined Communication Format for PowerFlex700S and 1756-DMD30


20-COMM-E Drive Ethernet Interface

Version 11.13.00/Version 11.12.00/Version 11.11.00/Version 11.10.00


Reports Enhancements
RSNetWorx for DeviceNet Navigation
Ladder Diagram Expression Builder
Restore RSLogix 5000 Settings
Controller Organizer Improvements
FBD Editor Improvements
PIDE_AUTOTUNE Structure Contains New Status Bits
Set and Clear Project Path
Cross Reference Sorting
Cam Editor Improvements
Translation Tool Enhancements
SIZE Instruction Lets You Specify an Array Tag

Version 10.04.00/Version 10.03.00/Version 10.02.00/Version 10.00.00


Message (MSG) Enhancements
FlexLogix5400 DeviceNet Support
Swap Byte (SWPB) Instruction
Download Performance Improvement
Export Performance Improvement
Jump to Subroutine (JSR) Support for BOOL Data Type
Support for 1771 Analog / Block Transfer over ControlNet
Toggle Bit in Data Monitor
Support the Windows Keyboard Application Key
Quick view pane
New axis types
Axis configuration dialogs
Motion group icons
Direct template data access
Axis parameter access using GSV/SSV

Version 9.00.00
Quick view pane
New axis types
Axis configuration dialogs
Motion group icons
Direct template data access
Axis parameter access using GSV/SSV

Version 8.52.00
A Redundancy tab has been added to the Controller Properties dialog, which displays the redundancy status, partner status, and partner minor faults, and allows you
to configure the memory usage.
The Get System Value (GSV) instruction has been enhanced to provide information about the new REDUNDANCY object, including: ChassisRedundancyState,
CompatibilityResults, KeyswitchAlarm, LastDataTransferSize, MaxDataTransferSize, ModuleRedundancyState, PartnerChassisRedundancyState, PartnerKeyswitch,
PartnerMinorFaults, PartnerMode, PartnerModuleRedundancyState, PhysicalChassisID, QualificationInProgress, and SRMSlotNumber. In addition, the Set System
Value (SSV) instruction can be used to reset the MaxDataTransferSize to zero.

Version 8.02.00
New Online Toolbar
New Path Toolbar
Tag Browser includes Description
Tag Editor/Data Monitor Unused Tags filter
Main and Fault routines distinguished in Controller Organizer
New Tag dialog added to pop-up menu
The size limit of 65535 bytes for a user-defined data type was removed.

Version 8.00.00
New Online Toolbar
New Path Toolbar
Tag Browser includes Description
Tag Editor/Data Monitor Unused Tags filter
Main and Fault routines distinguished in Controller Organizer
New Tag dialog added to pop-up menu

Version 7.02.00
The following enhancements to existing features have been made in this release.
Outputs are now updated at the end of the Task rather than at the end of each Program, thereby eliminating redundant updates and improving the controller scan
time. (CR235)
Additional messages have been implemented that indicate which area of memory (I/O, Data Table, or General) on the controller has been depleted if during
download you run out of memory. Refer to online help for further details. (CR239)
The serial port on Logix5000 controllers now supports baud rates up to 38,400.

Version 7.00.00
Outputs are now updated at the end of the Task rather than at the end of each Program, thereby eliminating redundant updates and improving the controller scan
time. (CR235)
Additional messages have been implemented that indicate which area of memory (I/O, Data Table, or General) on the controller has been depleted if during
download you run out of memory. Refer to online help for further details. (CR239)
The serial port on Logix5000 controllers now supports baud rates up to 38,400.

Version 6.03.00
A new .ACD file compression algorithm reduces the disk space required to store application files by more than 80%.
An optionally-installed, interactive ControlLogix Quick Tour tutorial is now available from the RSLogix 5000 Online Help menu.
The motion control functionality has been enhanced for high-speed packaging applications to include:
time-based position capture
master offset move for position cams
passive homing extensions (immediate and home switch only)
The Message Configuration functionality has been enhanced to support port numbers in IP addresses in the message path and to support a choice of DNS names or
numeric IP addresses in the message and communication paths.
The display of operand comments has been enhanced to optionally search the base tag for a description if the operand itself does not have a description

Version 6.01.00
A new .ACD file compression algorithm reduces the disk space required to store application files by more than 80%.
An optionally-installed, interactive ControlLogix Quick Tour tutorial is now available from the RSLogix 5000 Online Help menu.
The motion control functionality has been enhanced for high-speed packaging applications to include:
time-based position capture
master offset move for position cams
passive homing extensions (immediate and home switch only)

The Message Configuration functionality has been enhanced to support port numbers in IP addresses in the message path and to support a choice of DNS names or
numeric IP addresses in the message and communication paths.
The display of operand comments has been enhanced to optionally search the base tag for a description if the operand itself does not have a description

Version 6.00.00
A new .ACD file compression algorithm reduces the disk space required to store application files by more than 80%.
An optionally-installed, interactive ControlLogix Quick Tour tutorial is now available from the RSLogix 5000 Online Help menu.
The motion control functionality has been enhanced for high-speed packaging applications to include:
time-based position capture
master offset move for position cams
passive homing extensions (immediate and home switch only)
The Message Configuration functionality has been enhanced to support port numbers in IP addresses in the message path and to support a choice of DNS names or
numeric IP addresses in the message and communication paths.
The display of operand comments has been enhanced to optionally search the base tag for a description if the operand itself does not have a description

Version 5.02.00
A new .ACD file compression algorithm reduces the disk space required to store application files by more than 80%.
An optionally-installed, interactive ControlLogix Quick Tour tutorial is now available from the RSLogix 5000 Online Help menu.
The motion control functionality has been enhanced for high-speed packaging applications to include:
time-based position capture
master offset move for position cams
passive homing extensions (immediate and home switch only)
The Message Configuration functionality has been enhanced to support port numbers in IP addresses in the message path and to support a choice of DNS names or
numeric IP addresses in the message and communication paths.
The display of operand comments has been enhanced to optionally search the base tag for a description if the operand itself does not have a description
New axis types have been defined to align with a necessary rearchitecture of motion subsystems. There are now several motion axis data types where there was only
one type in prior releases. The new axis types are: AXIS_CONSUMED, AXIS_VIRTUAL, AXIS_SERVO, and AXIS_SERVO_DRIVE. This architectural
change was necessary to facilitate the addition of new types of motion axes in this release and in future releases.
Axis configuration dialogs have been redesigned for better organization and grouping of configuration parameters. New axis type, AXIS_SERVO_DRIVE, has
been added to support SERCOS-based servo drive axes when used in conjunction with 1756-M08SE module. Configuration dialogs display relevant data for an axis
based on its type and configuration settings.
Graphical iconic representations for axes have been added to the Controller Organizer. Quick access to configuration properties, faults, status, etc. are accessible via
mouse-driven context menus.
Motion Group graphical icon has been added to the Controller Organizer. This provides a quick visual display of all axes which are assigned to a motion group.
Assigning and unassigning axes can be accomplished through simple drag/drop/copy/paste using a mouse or pointing device.

Controller Organizer's I/O configuration has been updated so that SERCOS-based drives configured on their respective 1756-M08SE SERCOS controller module
appear below them in an hierarchical manner.
Quick-View Pane status display has been added to the bottom of the Controller Organizer. This display provides quick, top-level status information for the selected
task, module, SERCOS-based drive, or axis.
Direct Templated data access for commonly used axis tag attributes has been added to all motion axis types. This feature permits direct access and use of
commonly used axis data with instructions in the users program without having to store or retrieve these values through separate SSV/GSV instruction blocks.
GSV/SSV instructions now provide organized access to axis parameters based on whether the parameter is a configuration, status, or interface attribute.

Version 2.51.00
The 1794-IB16/A Input tag now has a 16-bit counter to count transitions on the input member counter.

Version 2.50.00
The 1794-IB16/A Input tag now has a 16-bit counter to count transitions on the input member counter.

Version 2.27.00
Added the ability to set IP address of 1756-ENET module via RSLogix 5000 I/O configuration In previous versions of RSLogix 5000 the only place you could set
the IP address was via the ControlLogix Gateway Configuration software. (CR88)
Added support to specify new request and response tags for CIP Data Table Read & Write messages The new types include an element of an array, a member of a
structure, and an element of an array that is a member of a structure. (CR156, 20537)
Allow messages larger than 500 bytes - CIP Data Table Read & Write messages will now allow transmission of more than 500 bytes of data. (CR184)
Added type ahead/auto-fill when entering tag names - As you begin typing in an edit field, RSLogix 5000 will automatically search the tag database for the first tag
that begins with the same sequence of characters and allow you to press enter to select it.
Allow individually configurable input and output data packet sizes for the 1756-DNB module of less than 500 bytes.
Modified the integer divide and square root instructions in the 1756-L1 firmware (4.42). Previously a fractional result may have been either truncated or rounded
up, depending on the value of the fractional result. Now, any fractional result of either of these integer instructions will always be truncated toward zero. (21447)
Removed the dynamic restrictions for the Motion Axis Jog (MAJ), Motion Axis Move (MAM), and Motion Change Dynamics (MCD) instructions.
Application errors are now recorded in the file RSLogix 5000 Fatal Error.Log" that can be emailed to Customer Support.

Version 2.25.00
Added the ability to set IP address of 1756-ENET module via RSLogix 5000 I/O configuration In previous versions of RSLogix 5000 the only place you could set
the IP address was via the ControlLogix Gateway Configuration software. (CR88)
Added support to specify new request and response tags for CIP Data Table Read & Write messages The new types include an element of an array, a member of a
structure, and an element of an array that is a member of a structure. (CR156, 20537)
Allow messages larger than 500 bytes - CIP Data Table Read & Write messages will now allow transmission of more than 500 bytes of data. (CR184)

Added type ahead/auto-fill when entering tag names - As you begin typing in an edit field, RSLogix 5000 will automatically search the tag database for the first tag
that begins with the same sequence of characters and allow you to press enter to select it.
Allow individually configurable input and output data packet sizes for the 1756-DNB module of less than 500 bytes.
Modified the integer divide and square root instructions in the 1756-L1 firmware (4.41). Previously a fractional result may have been either truncated or rounded
up, depending on the value of the fractional result. Now, any fractional result of either of these integer instructions will always be truncated toward zero. (21447)
Removed the dynamic restrictions for the Motion Axis Jog (MAJ), Motion Axis Move (MAM), and Motion Change Dynamics (MCD) instructions.
Application errors are now recorded in the file RSLogix 5000 Fatal Error.Log" that can be emailed to Customer Support.

Important Changes In This Release


The following items explain changes that have been made for this release in the way that RSLogix 5000 software works, compared to previous releases.

Version 13.00.00
MOTION_INSTRUCTION Data Type Change
Extra Digit of Precision Shown for REAL Data Type
PowerFlex 700S Drive Interface Module RPI Change
Controller Memory Changes
Import/Export Changes
Motion Objects and Instructions Changes

Version 12.03.00/12.02.00/Version 12.01.00/Version 12.00.00


MOTION_INSTRUCTION Data Type Change
Extra Digit of Precision Shown for REAL Data Type
PowerFlex 700S Drive Interface Module RPI Change
Controller Memory Changes
Import/Export Changes
Motion Objects and Instructions Changes
The following items explain changes that have been made for this release in the way that RSLogix 5000 software works, compared to previous releases.

Version 11.13.00/Version 11.12.00/Version 11.11.00/Version 11.10.00


Extra Digit of Precision Shown for REAL Data Type
PowerFlex 700S Drive Interface Module RPI Change
Controller Memory Changes
Import/Export Changes
Motion Objects and Instructions Changes

Version 10.04.00/Version 10.03.00/Version 10.02.00/Version 10.00.00


Controller Memory Changes
Import/Export Changes

Motion Objects and Instructions Changes

Version 9.00.00
Motion Objects and Instructions Changes
Import/Export Changes

Corrected Anomalies
The following anomalies have been corrected in the specified releases of RSLogix 5000. Refer to the Release Notes that accompany an individual version for more
detailed information on a particular feature.

Version 13.00.00
RSLogix 5000
Many product deficiencies have been addressed since Version 12. The most significant of these include:
The Forced indicator is not refreshing in Force mask field for Non-I/O tags (x44765)
RSLogix 5000 disappears re-referencing FBD block with connectors looped (x44631)
Motion Database has been updated for RSLogix V13 (x44222)
Going Offline sometimes causes an error Can't Close CIP RSLinx connection. (x44019)
SFC "remembers" step through command if issued when chart is paused (x43879)
PID arrays do not scale properly in PID instruction (x43666)
Function block Ramp Soak (RMPS) Initialization ignores segment 0 soak time (x 43665)
Fatal Error extending branch when converge and element below are selected (x43463)
Fatal Error on switch between versions after FindAll (x43274)
When using the "Edit > Show all actions in routine" function in the SFC Editor, RSLogix 5000 frequently reports a Fatal Error. (x42813)
After doing a Find (Find All or Find Next) in one version of RSLogix 5000 and then attempting to switch versions a Fatal Error occurs in the version of RSLogix
5000 that is being closed. (x43274)
A RSLogix 5000 Fatal Error occurs if you attempt to import tags with descriptions for a module-defined tag (x42489)
RSLogix 5000 Fatal Errors on close of the application after a failed attempted download of FBD routine(s). The download error was reported as Error: Reference
tag not found. To correct the problem, open the project with RSLogix 5000 V13.00 and either export and import the project or select File -> Compact before
downloading to the controller. (x42486)
Mini activation key allows controller morphing to non-supported controller types (x42817)
In a Message (MSG) Instruction, you cannot set or clear certain status bits. Do not set or clear the following bits of a Message (MSG) instruction: EW, ER, DN, or
ST. If you set or clear one of those bits, RSLogix 5000 software displays the change, but the MSG instruction ignores the change and continues to execute based on
the internally-stored value of those bits. (x42349)
Newer versions of SFC copy functionality not compatible with V11 SFC Editor (x42272)
Drag and drop of Structured Text from embedded editor causes Fatal Error (x41889)
RSLogix 5000 Fatal Error on close of application after failed attempted download of FBD routine (x41878)
Importing a newer version L5K file in an older version generates a syntax error (x41795)

AutoFlash is not available when minor revision is less than lock step requires (x41737)
Must set the DF1 Pending Token Hold Factor to 1 in L5K file then import in order to download (x41698)
Output Cam Editor disable OK button in run mode, same as Cam Profile Editor (x41510)
The Label (LBL) instruction must be the first instruction in a rung. This restriction is now enforced by the RSLogix 5000 software. If you had previous version
projects where the LBL instruction was not the first instruction in the rung, edit the logic to move it to the first position and re-verify your project. (x41413, x41346)
Unable to run a trend if logged with no administrative privileges (x41332)
Corrected source protection handling of Structured Text (ST) routines (x41098)
Uploading with causes some messages tags to be lost or corrupted (x40879)
A Fatal Error occurs when uploading or downloading FBD routines with blocks with arrays or PIDE with Autotune tag (x40729)
A Fatal Error occurs if a File > Save is attempted while the SERCOS error condition "No More Available Nodes on this Network" exists in the project. (x40559)
Importing incomplete I-R or i-r pairs of rungs may lead to a Fatal Error (x39637)
When a GSV (or SSV) with a class of CoordinateSystem is entered in a ST routine and then verified, a Fatal Error occurs. (x39623)
Major Fault caused by array index out of range when transitioning from program mode to run mode (x40220)
The Launch RSFieldbus push button fails (x40106)
User-defined faults have incorrect information in the fault log (x37633)
Go Online, Upload, or Download push buttons not enabled in Who Active dialog or error Failed to go online with the controller. Unsupported Processor type.
for controllers not supported in current version of RSLogix 5000. (x39378, x28918)
Support processor series/major rev identification (x38763)
Canceling edits during "synchronization" does not remove edit view sheet in FBD Editor (x34751)
Search/Replace does not always find all occurrences when searching descriptions in arrays, structures, and tags of user-defined types. (x27744)
The default setting for the Auto Tag Update attribute for both the MOTION_GROUP and COORDINATE_SYSTEM data types has changed from Disabled to
Enabled for all newly created tags of these types. This does not effect importing or conversions of older projects. (x26921)

ControlLogix5550/ControlLogix5555/ControlLogix5561/ControlLogix5562/ControlLogix5563
Refer to the Firmware Release Notes for the ControlLogix family of controllers (Publication 1756-RN603A-EN-E March 2004) to review the most significant
problems that have been fixed.

CompactLogix5320/CompactLogix5330/CompactLogix5331/CompactLogix5332E/CompactLogix5335CR/CompactLogix5
335E
Refer to the Firmware Release Notes for the CompactLogix family of controllers (Publication 1769-RN008A-EN-P March 2004) to review the most significant
problems that have been fixed.

FlexLogix5433/FlexLogix5434
Refer to the Firmware Release Notes for the FlexLogix family of controllers (Publication 1794-RN013A-EN-E March 2004) to review the most significant problems
that have been fixed.

SoftLogix5800
Refer to the Release Notes for the SoftLogix controller (Publication 1789-RN516A-EN-E March 2004) to review the most significant problems that have been fixed.

Version 12.03.00/12.02.00/Version 12.01.00/Version 12.00.00


RSLogix 5000
Several product deficiencies discovered in Version 12.02 have been corrected in Version 12.03. These include:
RSLogix 5000 hangs after creating circular alias tag (x45430)
Search and Replace does not find all JSR parameters in LD routines (x45415)
Hidden members re-referenced for User-Defined Types with addition of new UDT members (x45325)
The Forced indicator is not refreshing in Force mask field for Non-I/O tags (x44928)
RSLogix 5000 disappears re-referencing FBD block with connectors looped (x44711)
Motion Database has been updated for RSLogix V12 (x44485)
Going Offline sometimes causes an error Can't Close CIP RSLinx connection. (x44181)
SFC "remembers" step through command if issued when chart is paused (x43964)
Function block Ramp Soak (RMPS) Initialization ignores segment 0 soak time (x 43954)
PID arrays do not scale properly in PID instruction (x43666)
Fatal Error extending branch when converge and element below are selected (x43504)
Fatal Error on switch between versions after Find All (x43397)
Mini activation key allows controller morphing to non-supported controller types (x42817)
RSLogix 5000 Fatal Error on close of application after failed attempted download of FBD routine (x42485)
Importing a newer version L5K file in an older version generates a syntax error (x42253)
AutoFlash is not available when minor revision is less than lock step requires (x42164, x41872)
Output Cam Editor disable OK button in run mode, same as Cam Profile Editor (x41805)
Must set the DF1 Pending Token Hold Factor to 1 in L5K file then import in order to download (x41700)
The Launch RSFieldbus push button fails (x39981)
Support processor series/major revision identification for AutoFlash (x38763)
Several product deficiencies discovered in Version 12.01 have been corrected in Version 12.02. These include:
Scrolling with wheel mouse causes repaint problems in the Ladder Diagram editor (x42340)
Copying V12 SFC elements to the clipboard cause a fatal error opening SFC routines in V11 (x42289)
Can not JSR from SFC routines without ST activation key present (x42187)
Uploading projects with tag references to remote I/O with module names greater than 36 characters deletes logic in Ladder Diagram routines (x42153)
Array index out of range for Ladder Diagram counter and timer instructions during prescan results in I_B_DEAD (x 42059)

RSLogix 5000 fatal error on close of application after failed attempted download of FBD routine(s). The download error was reported as Error: Reference tag not
found. To correct the problem, open the project with RSLogix 5000 V12.02 and either export and import the project or select File -> Compact before
downloading to the controller. (x41878)
The Axis Servo Drive data type SERCOS Ring Fault, Torque Limit Source, and DC Bus Voltage attributes are not correct in V12 after conversion from a previous
version (x41830, x41829, x40379). Re-open the project and download to correct the problems.
Possible to get an Invalid Routine Type fault after verifying and downloading a SoftLogix project. (x41675).
RSLinx screening of newer Logix5000 controllers prevents online operations in RSLogix 5000 (x41625).
Uploading an FBD routine containing a DEDT, FGEN, MAVE, MSTD, PIDE, RMPS function blocks may silently modify the project, may cause a Fatal Error,
and any faults generated by these blocks will report an unknown location in the Fault Log. (x41550).
Corrected source protection handling of Structured Text (ST) routines (x41481).
Unable to run a trend if logged in without Administrator privileges (x 41412).
Verifying a GSV or SSV in a Structured Text routine with a Class attribute of CoordinateSystem causes a Fatal Error (x39661).
Several product deficiencies discovered in Version 12.00 have been corrected in Version 12.01. These include:
Online original rung and edited rung both scanned after reboot in SoftLogix5800 (x39323)
Alias target of an I/O tag can be edited to point to the wrong slot of the rack image (x39258)
Pasting tags referenced in FBD routine to Unscheduled programs tag folder causes Fatal Error (x39220)
Multiple Find Next searches results in Fatal Error (x38692)
FBD routine text is hard to read (gray) (x38583)
Many product deficiencies have been addressed since Version 11.00. The most significant of these include:
A project converted from V10 can be downloaded but not uploaded due to keyword (x38402)
Adding SFC elements to routine without Full Access by drag & drop, leads to Fatal (x37078)
Delete enabled in ST routines main menu without Full Access leads to Fatal (x37066)
RSLogix 5000 crashes when change STOR to STOD online run mode on SoftLogix (x36983)
Pasting in code with errors into ST routine will cause RSLogix 5000 to freeze. (x36968)
Fatal Error in Source Protection tooltip for Protected Routine with maximum name length (x36711)
Fatal Error deleting SFC element that has undefined backing tag alias (x36316)
Problems in Data type with Fake Commit. (x36150)
Member array indexing of nested structure not working (x36041)
Morphing a project with forced I/O causes a fatal error. (x35981)
FAL instruction occasionally compiles incorrect code (x35029)
Misleading message when Forward Open fails (x35024)
Fatal Error importing an L5k file if the routine name length exceeds 43 Char. (x34633)
Message CIP Data Table Remote Element no longer allows colon in tag name. (x34596)
SFC Copy/Paste should not rename elements unless there is a collision (x34425)

Multi-Workstation Program mode edit causes rungs to disappear in second session (x34398)
Fatal Error on right mouse click for transition below simultaneous branch connected to select (x34377)
I/O Configuration tags incorrectly put in I/O memory. (x34012)
Crashes when deleting specific SFC routine, when it is being edited (x33760)
Fatal Error opening routine with bad Text Box attachment to Action (x33666)
Watch pane Fatal Error on double-click of Tag Name column with no tags (x33658)
Projects that fail to open due to Ctree error can now be opened in V12 (x33380)
Running a Trend object on a 6180 industrial computer causes RSLogix 5000 to fatal. (x33154)
Rare fatal error when data type becomes unverified (x32870)
Message configuration dialog does not refresh RemoteElement from tag (x31626)
Modifying CNB properties causes Fatal Error RxComponent.cpp (x30683)

ControlLogix5550/ControlLogix5555/ControlLogix5561/ControlLogix5562/ControlLogix5563
Refer to the Firmware Release Notes for the ControlLogix family of controllers (Publication 1756-RN601B-EN-E June 2003) to review the most significant problems
that have been fixed.

CompactLogix5320 / CompactLogix5330/CompactLogix5335E
Refer to the Firmware Release Notes for the CompactLogix family of controllers (Publication 1769-RN006A-EN-P June 2003) to review the most significant
problems that have been fixed.

FlexLogix5433 / FlexLogix5434
Refer to the Firmware Release Notes for the FlexLogix family of controllers (Publication 1794-RN012A-EN-P June 2003) to review the most significant problems
that have been fixed.

Version 11.13.00/Version 11.12.00/Version 11.11.00/Version 11.10.00


A few product deficiencies discovered in Version 11.12 have been corrected in Version 11.13. These include:
Search and Replace does not find all JSR parameters in LD routines (x45413)
Hidden members re-referenced for User-Defined Types with addition of new UDT members (x45324)
SFC "remembers" step through command if issued when chart is paused (x43965)
Function block Ramp Soak (RMPS) Initialization ignores segment 0 soak time (x43953)
Fatal Error extending branch when converge and element below are selected (x43503)
Fatal Error switching versions with branch displayed (x42443)
Scrolling with wheel mouse causes problems with Ladder Editor display (x42339)
Importing a newer version L5K file in an older version generates a syntax error (x42254)

AutoFlash is not available when minor revision is less than lock step requires (x41873)
Output Cam Editor disable OK button in run mode, same as Cam Profile Editor (x41806)
Go Online, Upload, or Download push buttons not enabled in Who Active dialog or error Failed to go online with the controller. Unsupported Processor type.
for controllers not supported in current version of RSLogix 5000. (x41624)
Corrected source protection handling of Structured Text (ST) routines (x41520)
Support processor series/major revision identification for AutoFlash (x38762)
A few product deficiencies discovered in Version 11.11 were corrected in Version 11.12. These include:
Online edit dragging of multiple instructions in Ladder diagram results in unintended move (x39406)
Pasting tags referenced in FBD routine to Unscheduled programs tag folder causes Fatal Error (x39269)
Alias target of an I/O tag can be edited to point to the wrong slot of the rack image (x39267)
Copying a new instruction from V12 into a V11 project causes a Fatal Error (x38803)
A Sequential Function Chart with 6 or more simultaneous branch legs won't verify (x38146)
Uploading using LogixServices doesn't merge, so comments are lost (x38130)
Misleading firmware incompatibility message when connecting online over intermediate communication paths (x38128)
Several product deficiencies discovered in Version 11.10 were corrected in Version 11.11. These include:
Fixed a Fatal Error verifying ST routines with incomplete PIDE instructions (x33928)
Corrected a problem with the start and end slopes for 2-point cams (x33698)
Fixed a problem with online editing ladder routines in a 1756-L63 controller (x33656)
Modified the "Change CST Master" wording to indicate possible unexpected motion (x33565)
Fixed an incorrect ProgID for automation interfaces (x33490)
Corrected a Fatal Error opening SFC routines after deleting a branch with a text box attached (x33483)
Fixed a Fatal Error opening Ladder Diagram routines with the Show Quick Key Configuration option selected (x33474)
Corrected the 1407-CGCM module poles ratio check and maximum poles allowed (x33436)
Several product deficiencies discovered in Version 10.00 were corrected in Version 11.10.00. These include:
Message configuration dialog displayed incorrectly when tag changes from unverified to verified (x30698)
Fatal Error changing window focus if Tag Browser or tag edit control open in FBD routine (x30622)
Unable to open an ACD file - Get Invalid access to memory location (x30538)
Fatal Error or RSLogix 5000 hangs after freeing memory when resources are low (x29956)
Fatal Error after printing Special Properties for an AXIS type tag (x29681)
Fatal errors when converting an ACD file from version 8 to 10 (x29547)
Message configuration dialog does not refresh most parameters from tag (x27864)
Fatal Error after programmatically modifying message parameters (x27845)
Produced/consumed tag problems after changing the size of a User-Defined Type (x27225)

ControlLogix5550/ControlLogix5553/ControlLogix5555
Refer to the Firmware Release Notes for the ControlLogix family of controllers (Publication 1756-RN004R-EN-E August 2002) to review the most significant
problems that have been fixed.

Version 10.04.00/Version 10.03.00/Version 10.02.00/Version 10.00.00


RSLogix 5000
A few product deficiencies discovered in Version 10.03 have been corrected in Version 10.04. These include:
Search and Replace does not find all JSR parameters in LD routines (x45414)
Hidden members re-referenced for User-Defined Types with addition of new UDT members (x45323)
Function block Ramp Soak (RMPS) Initialization ignores segment 0 soak time (x43952)
Fatal Error clicking Update Firmware push button (x43899)
Scrolling with wheel mouse causes problems with Ladder Editor display (x42338)
Importing a newer version L5K file in an older version generates a syntax error (x42255)
AutoFlash is not available when minor revision is less than lock step requires (x41874)
Output Cam Editor disable OK button in run mode, same as Cam Profile Editor (x41807)
Support processor series/major revision identification for AutoFlash (x38761)
Go Online, Upload, or Download push buttons not enabled in Who Active dialog or error Failed to go online with the controller. Unsupported Processor type.
for controllers not supported in current version of RSLogix 5000. (x28918)
A few product deficiencies discovered in Version 10.02 were corrected in Version 10.03. These include:
Alias target of an I/O tag can be edited to point to the wrong slot of the rack image (x39268)
Fatal Error uploading project from 1756-L63 controller after type changed from 1756-L55 (x38934)
Uploading using LogixServices doesn't merge, so comments are lost (x38133)
Misleading firmware incompatibility message when connecting online over intermediate communication paths (x38129)
Several product deficiencies discovered in Version 10.00 were corrected in Version 10.02. These include:
Fixed a problem with online editing ladder routines in a 1756-L63 controller (x33656)
Corrected a Fatal Error during upload from a 1756-L63 controller (x33654)
Added an automation interface for RSMACC (x33507)
Corrected a problem with duplicate input and output parameters on JSR instructions in FBD routines (x33421)
Fixed a Fatal Error going online after a download (x33373)
Added activation key support for the Full package and PIDE Autotune in the Professional package (x33301)
Corrected a problem switching versions when creating a V11 project from within V10 (x32783)
Fixed a problem displaying the splash screen (x32623)
Corrected an attribute list error on the serial port after multiple downloads (x32615)

Fixed the source protection algorithm for Windows XP (x32614)


Corrected the database file compression algorithm (x32613)
Fixed a problem with the major revision check for Import (x32611)
Several product deficiencies discovered in Version 8.02 were corrected in Version 10.0. The most significant of these include:
Fatal Error when deleting an open FBD routine referenced in a Ladder Diagram JSR (x27957)
Fatal error when you open a FBD routine, print it, and then edit it (x26735)
Importing new tags loses descriptions when discard on collision is selected (x23026)
RSLogix5000 locks up when searching large program file (x27813)
Accessing the Sheet Tool Bar in the FBD Editor with an incomplete wire causes Fatal Error (x25562, x25138)
Deleting tag elements in the Tag Editor with a filter of COUNTER or TIMER causes a fatal error (x23806, x22223, x22629)
Downloading an FBD IREF with alias to Boolean array member of a user-defined type tag encounters unexpected error and ultimately Fatal Errors (x23897)
Excessive embedded cross reference information in Ladder Logic listings (x23021)
RSLogix 5000 fatal error when right click in RSTrend window (x22503)
Source Protection not encrypted when viewed with traffic analyzer (x21919)
Deleting FBD routine when in editor causes fatal error (x21742, x21620)
Tag references to array elements are changed after upload (x21598)
Closing RSLogix 5000 after adding FBD elements causes fatal error in Windows 2000 (x19332)

Logix5550/Logix5553/Logix5555
Refer to the Firmware Release Notes for the Logix5000 family of controllers (Publication 1756-RN004N-EN-E December 2001) to review the most significant
problems that have been fixed.

Version 9.00.00
RSLogix 5000
Many product deficiencies have been addressed since Version 7.00. The most significant of these include:
Accessing the Sheet Tool Bar in the FBD Editor with an incomplete wire causes Fatal Error (x25562, x25138)
Deleting tag elements in the Tag Editor with a filter of COUNTER or TIMER causes a fatal error (x23806, x22223, x22629)
Downloading an FBD IREF with an alias to a Boolean array member of a user-defined type tag encounters an unexpected error and, ultimately, Fatal Errors
(x23897)
Excessive embedded cross reference information in Ladder Logic listings (x23021)
RSLogix 5000 fatal error when right click in RSTrend window (x22503)
Source Protection not encrypted when viewed with traffic analyzer (x21919)
Deleting FBD routine when in editor causes fatal error (x21742, x21620)

Tag references to array elements are changed after upload (x21598)


Closing RSLogix 5000 after adding FBD elements causes fatal error in Windows 2000 (x19332)

Logix5550/Logix5553/Logix5555
Refer to the Firmware Release Notes for the Logix5000 family of controllers (Publication 1756-RN004M-EN-E August 2001) to review the most significant problems
that have been fixed.

Version 8.52.00
RSLogix 5000
Many product deficiencies have been fixed since Version 7.00. The most significant problems that have been fixed include:
Advanced redundancy properties are inactive (x27497)
Accessing the Sheet Tool Bar in the FBD Editor with an incomplete wire causes Fatal Error (x25562, x25138)
Deleting tag elements in the Tag Editor with a filter of COUNTER or TIMER causes a fatal error (x23806, x22223, x22629)
Downloading an FBD IREF with an alias to a Boolean array member of a user-defined type tag encounters an unexpected error and, ultimately, Fatal Errors
(x23897)
Excessive embedded cross reference information in Ladder Logic listings (x23021)
RSLogix 5000 fatal error when right click in RSTrend window (x22503)
The Module Create Wizard for 1769-MODULE does not allow access to tabs (x22007, x21372)
Source Protection not encrypted when viewed with traffic analyzer (x21919)
Deleting FBD routine when in editor causes fatal error (x21742, x21620)
Tag references to array elements are changed after upload (x21598)
Closing RSLogix 5000 after adding FBD elements causes fatal error in Windows 2000 (x19332)

Logix5550/Logix5553/Logix5555
Refer to the Firmware Release Notes for the Logix5000 family of controllers (Publication 1756-RN004L-EN-E June 2001) to review the most significant problems
that have been fixed.
Refer to the ControlLogix Redundancy System Release Notes (Publication 1756-RN582A-EN-E - August 2001) for further information about the redundancy system
components including 1756-L55 and -L55Mxx, 1756-CNB/D and -CNBR/D, and 1757-SRM.

Version 8.02.00
RSLogix 5000
Many product deficiencies have been fixed since Version 7.00. The most significant problems that have been fixed include:

Accessing the Sheet Tool Bar in the FBD Editor with an incomplete wire causes Fatal Error (x25562, x25138)
Deleting tag elements in the Tag Editor with a filter of COUNTER or TIMER causes a fatal error (x23806, x22223, x22629)
Downloading an FBD IREF with an alias to a Boolean array member of a user-defined type tag encounters an unexpected error and, ultimately, Fatal Errors
(x23897)
Excessive embedded cross reference information in Ladder Logic listings (x23021)
RSLogix 5000 fatal error when right click in RSTrend window (x22503)
The module create wizard for 1769-MODULE does not allow access to tabs (x22007, x21372)
Source Protection not encrypted when viewed with traffic analyzer (x21919)
Deleting FBD routine when in editor causes fatal error (x21742, x21620)
Tag references to array elements are changed after upload (x21598)
Closing RSLogix 5000 after adding FBD elements causes fatal error in Windows 2000 (x19332)
A product deficiency was fixed in Version 7.02 that was found in Version 7.00. The problem only involved SoftLogix5860 controllers. The problem that has been fixed
is:
Instructions involving copy operations in SoftLogix5860 can overwrite memory if the destination operand is a member of an array tag or user-defined type tag.
(x22731)

Logix5550/Logix5553/Logix5555
Refer to the Firmware Release Notes for the Logix5000 family of controllers (Publication 1756-RN004L-EN-E June 2001) to review the most significant problems
that have been fixed.

Version 8.00.00
RSLogix 5000
Many product deficiencies have been fixed since Version 7.00. The most significant problems that have been fixed include:
Deleting tag elements in the Tag Editor with a filter of COUNTER or TIMER causes a fatal error (x23806, x22223, x22629)
Downloading an FBD IREF with an alias to a Boolean array member of a user-defined type tag encounters an unexpected error and, ultimately, Fatal Errors
(x23897)
Excessive embedded cross reference information in Ladder Logic listings (x23021)
RSLogix 5000 fatal error when right click in RSTrend window (x22503)
The module create wizard for 1769-MODULE does not allow access to tabs (x22007, x21372)
Source Protection not encrypted when viewed with traffic analyzer (x21919)
Deleting FBD routine when in editor causes fatal error (x21742, x21620)
Tag references to array elements are changed after upload (x21598)
Closing RSLogix 5000 after adding FBD elements causes fatal error in Windows 2000 (x19332)

A product deficiency was fixed in Version 7.02 that was found in Version 7.00. The problem only involved SoftLogix5860 controllers. The problem that has been fixed
is:
Instructions involving copy operations in SoftLogix5860 can overwrite memory if the destination operand is a member of an array tag or user-defined type tag.
(x22731)

Logix5555
Refer to the Firmware Release Notes for the ControlLogix5555 controller (Publication 1756-RN578A-EN-E May 2001) to review the most significant problems that
have been fixed.

Version 7.02.00
RSLogix 5000
A product deficiency has been fixed in Version 7.02 that was found in Version 7.00. The problem only involved SoftLogix5860 controllers. The problem that has been
fixed is:
Instructions involving copy operations in SoftLogix5860 can overwrite memory if the destination operand is a member of an array tag or user-defined type tag.
(x22731)
Many product deficiencies have been fixed since Version 6.00. The most significant problems that have been fixed include:
Unexpected data values are possible when using two Input References (IREF) with the same tag in the same FBD routine and the tag data type is changed (x21608)
Morphing Boolean Relay Ladder Language instructions to AFI or NOP causes a fatal error or locks up RSLogix 5000 (x20931, x20359, x20250)
Search & Replace replaces entire operand within multi-operand instructions (x20327)
Relay Ladder Language motion instructions MCCP, MAPC, and MATC do not allow non-zero index Cam Profile array entries. The Cam Profile operand must be
element zero of the array. (x19879)
Corrupt database and fatal error if a controller-scoped tag of a user-defined type is deleted when aliased by a program-scoped tag (x19803)
RSLogix 5000 communication locks up during online editing (x16422)
Corrupt Cam or Cam Profile data causes a Fatal Error when opening the Cam Editor (x15900)

Logix5550/Logix5553/Logix5555
Refer to the Firmware Release Notes for the Logix5000 family of controllers (Publication 1756-RN004K-EN-P March 2001) to review the most significant problems
that have been fixed.

Version 7.00.00
Many product deficiencies have been fixed since Version 6.00. The most significant problems that have been fixed include:
Unexpected data values are possible when using two Input References (IREF) with the same tag in the same FBD routine and the tag data type is changed (x21608)
Morphing Boolean Relay Ladder Language instructions to AFI or NOP causes a fatal error or locks up RSLogix 5000 (x20931, x20359, x20250)
Search & Replace replaces entire operand within multi-operand instructions (x20327)

Relay Ladder Language motion instructions MCCP, MAPC, and MATC do not allow non-zero index Cam Profile array entries. The Cam Profile operand must be
element zero of the array. (x19879)
Corrupt database and fatal error if a controller-scoped tag of a user-defined type is deleted when aliased by a program-scoped tag (x19803)
RSLogix 5000 communication locks up during online editing (x16422)
Corrupt Cam or Cam Profile data causes a Fatal Error when opening the Cam Editor (x15900)

Logix5550/Logix5553/Logix5555
Refer to the Firmware Release Notes for the Logix5000 family of controllers (Publication 1756-RN004H-EN-P - November 2000) to review the most significant
problems that have been fixed.

Version 6.03.00
RSLogix 5000
A product deficiency has been fixed in Version 6.03 that was found in Version 6.00. The problem that has been fixed is:
Relay Ladder Language Motion instructions MCCP, MAPC, and MATC do not allow non-zero index Cam Profile array entries. The Cam Profile operand must be
element zero of the array. (x19879)
Many product deficiencies have been fixed since Version 2.51. The most significant problems that have been fixed include:
Fatal Error of GPF when right-click on bit number in 'bit-picker' (x18316, x18300)
The ladder listing report truncates rungs at the bottom of a page (x18068)
Fatal Error when morphing COP & MOV instructions with UDT elements (x18006)
Tag import from *.csv files does not work with international Windows and Excel (x17517)
Memory leak when focus changes in Controller Organizer and Tag Editor is open (x16767)
Serial Port Parity setting displays incorrect value (x16241, x16973)
Fatal Error when deleting alias information in the Tag Editor (x16579, x18525)
Upload after rescheduling a ControlNet network fails with error Data upload did not complete. CIP error: Invalid IOI destination. (x16109, x11664)
Unexpected disconnection when forcing slot status bits in a rack optimized input image (x13537)
Consumed tags based on user-defined data types revert to base tags when UDT changed (x11661)
The RSLogix 5000 software may lock up while copying and pasting a module from another project. (x06223)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-RN004F-EN-P August 2000) to review the most significant problems that have
been fixed.

Version 6.01.00
RSLogix 5000
A product deficiency has been fixed in Version 6.01 that was found in Version 6.00. The problem that has been fixed is:
Relay Ladder Language Motion instructions MCCP, MAPC, and MATC do not allow non-zero index Cam Profile array entries. The Cam Profile operand must be
element zero of the array. (x19879)
Many product deficiencies have been fixed since Version 2.51. The most significant problems that have been fixed include:
Fatal Error of GPF when right-click on bit number in 'bit-picker' (x18316, x18300)
The ladder listing report truncates rungs at the bottom of a page (x18068)
Fatal Error when morphing COP & MOV instructions with UDT elements (x18006)
Tag import from *.csv files does not work with international Windows and Excel (x17517)
Memory leak when focus changes in Controller Organizer and Tag Editor is open (x16767)
Serial Port Parity setting displays incorrect value (x16241, x16973)
Fatal Error when deleting alias information in the Tag Editor (x16579, x18525)
Upload after rescheduling a ControlNet network fails with error Data upload did not complete. CIP error: Invalid IOI destination. (x16109, x11664)
Unexpected disconnection when forcing slot status bits in a rack optimized input image (x13537)
Consumed tags based on user-defined data types revert to base tags when UDT changed (x11661)
The RSLogix 5000 software may lock up while copying and pasting a module from another project. (x06223)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-RN004F-EN-P August 2000) to review the most significant problems that have
been fixed.

Version 6.00.00
RSLogix 5000
Many product deficiencies have been fixed since Version 2.51. The most significant problems that have been fixed include:
Fatal Error of GPF when right-click on bit number in 'bit-picker' (x18316, x18300)
The ladder listing report truncates rungs at the bottom of a page (x18068)
Fatal Error when morphing COP & MOV instructions with UDT elements (x18006)
Tag import from *.csv files does not work with international Windows and Excel (x17517)
Memory leak when focus changes in Controller Organizer and Tag Editor is open (x16767)
Serial Port Parity setting displays incorrect value (x16241, x16973)
Fatal Error when deleting alias information in the Tag Editor (x16579, x18525)

Upload after rescheduling a ControlNet network fails with error Data upload did not complete. CIP error: Invalid IOI destination. (x16109, x11664)
Unexpected disconnection when forcing slot status bits in a rack optimized input image (x13537)
Consumed tags based on user-defined data types revert to base tags when UDT changed (x11661)
The RSLogix 5000 software may lock up while copying and pasting a module from another project. (x06223)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-RN004F-EN-P August 2000) to review the most significant problems that have
been fixed.

Version 5.02.00
RSLogix 5000
A product deficiency has been fixed in Version 5.01 and 5.02 that was found in Version 6.00:
Relay Ladder Language Motion instructions MCCP, MAPC, and MATC do not allow non-zero index Cam Profile array entries. The Cam Profile operand must be
element zero of the array. (x19879)
Many product deficiencies have been fixed since Version 2.51. The most significant problems that have been fixed include:
Fatal Error of GPF when right-click on bit number in 'bit-picker' (x18316, x18300)
The ladder listing report truncates rungs at the bottom of a page (x18068)
Fatal Error when morphing COP & MOV instructions with UDT elements (x18006)
Tag import from *.csv files does not work with international Windows and Excel (x17517)
Memory leak when focus changes in Controller Organizer and Tag Editor is open (x16767)
Serial Port Parity setting displays incorrect value (x16241, x16973)
Fatal Error when deleting alias information in the Tag Editor (x16579, x18525)
Upload after rescheduling a ControlNet network fails with error Data upload did not complete. CIP error: Invalid IOI destination. (x16109, x11664)
Unexpected disconnection when forcing slot status bits in a rack optimized input image (x13537)
Consumed tags based on user-defined data types revert to base tags when UDT changed (x11661)
The RSLogix 5000 software may lock up while copying and pasting a module from another project. (x06223)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-RN004F-EN-P August 2000) to review the most significant problems that have
been fixed.

Version 2.51.00
RSLogix 5000
Many product deficiencies have been fixed since Version 2.25. The most significant problems that have been fixed include:
Ladder editor routine names not displayed correctly and then Fatal Error (x13346)
Unable to upload from a running controller when change log is full (x11507)
Export skips all tags after an orphan tag and reports success (x11224)
Controller Organizer can be undocked & lost from view (x11098)
Automation Interface does not support two instances of RSLogix5000 (x11056)
CAM_PROFILE arrays in user-defined structures (x10982)
Ladder elements disappear when using mouse wheel in tag drop-down list (x10874)
Fatal error while downloading controller tags (x10844)
Deleting and inserting a rung 0 online prevents accepting pending edits (x10813)
1756-DNB Connection name lost on export (x10742)
Selecting a tag name in the PLC/SLC Mapping dialog causes a Fatal Error (x10566)
Missing Information in Cross Reference for elements of large arrays (x10393)
Cannot assign module to position only axis (x10297)
Unexpected CTree error when opening a .ACD file. (x05794)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-10.1-RN1 February 2000) to review the most significant problems that have been
fixed.

Version 2.50.00
RSLogix 5000
Many product deficiencies have been fixed since Version 2.25. The most significant problems that have been fixed include:
Unable to upload from a running controller when change log is full (x11507)
Export skips all tags after an orphan tag and reports success (x11224)
Controller Organizer can be undocked & lost from view (x11098)
Automation Interface does not support two instances of RSLogix5000 (x11056)
CAM_PROFILE arrays in user-defined structures (x10982)
Ladder elements disappear when using mouse wheel in tag drop-down list (x10874)
Fatal error while downloading controller tags (x10844)

Deleting and inserting a rung 0 online prevents accepting pending edits (x10813)
1756-DNB Connection name lost on export (x10742)
Selecting a tag name in the PLC/SLC Mapping dialog causes a Fatal Error (x10566)
Missing Information in Cross Reference for elements of large arrays (x10393)
Cannot assign module to position only axis (x10297)
Unexpected CTree error when opening a .ACD file. (x05794)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-10.1-RN1 February 2000) to review the most significant problems that have been
fixed.

Version 2.27.00
RSLogix 5000
Many product deficiencies have been fixed since Version 2.10. The most significant problems that have been fixed include:
Application error while online editing in run mode (21383)
Rapid entry of tag values in ladder produces Fatal Error (21167)
Import failed after translation from .PC5 when there are symbols for indirect addresses (21271)
Fatal application error when selecting Edit Ladder Element (21085)
Fatal Error due to extra tag browser (20986)
Fatal Error configuring Timer/Counter instructions (20950)
Fatal Error accepting Command Line Editor text (20818)
Hangs on assemble edits - two routines in program (20794)
Fatal Error closing routine - clipboard involved (20771)
Fatal Error when Working with Ladder Instructions (20743)
Infrequent RSLogix 5000 Fatal Errors while closing routines (20690)
Online edits of Operand comments causes application Fatal Error (20689)
Import and export time for large data arrays has been dramatically improved (20685)
Application Error while assembling edits after making online edits (20618)
Loss of work when a tag is not completely entered (20569)
Uploading controllers having a large number of modules (20515)
Responsiveness when online with large number of I/O modules improved (20495)
Upload fatal error for controllers with DHRIO modules configured for DH+/DH+ (20352)
Upload fails in some configurations of DHRIO modules (20429)

Module descriptions lost on upload/merge (20071)


Can not upload program from a busy controller (19865)
Cross reference of unverified and typeless tags (19680)
Focus problem prevented search from finding any occurrences (19668)
General Fault Type of motion group not being exported (19217)
Cross reference view updates are slow for large number of references (19149)
Operand comments lost on ASB size change (19130)
Rack optimized tag comments lost after export and re-import (19127)
Online rung edit causes application Fatal Error (18927)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-10.1-RN1 - October 1999) to review the most significant problems that have been
fixed.

Version 2.25.00
RSLogix 5000
Many product deficiencies have been fixed since Version 2.10. The most significant problems that have been fixed include:
Application error while online editing in run mode (21383)
Rapid entry of tag values in ladder produces Fatal Error (21167)
Import failed after translation from .PC5 when there are symbols for indirect addresses (21271)
Fatal application error when selecting Edit Ladder Element (21085)
Fatal Error due to extra tag browser (20986)
Fatal Error configuring Timer/Counter instructions (20950)
Fatal Error accepting Command Line Editor text (20818)
Hangs on assemble edits - two routines in program (20794)
Fatal Error closing routine - clipboard involved (20771)
Fatal Error when Working with Ladder Instructions (20743)
Infrequent RSLogix 5000 Fatal Errors while closing routines (20690)
Online edits of Operand comments causes application Fatal Error (20689)
Import and export time for large data arrays has been dramatically improved (20685)
Application Error while assembling edits after making online edits (20618)
Loss of work when a tag is not completely entered (20569)
Uploading controllers having a large number of modules (20515)

Responsiveness when online with large number of I/O modules improved (20495)
Upload fatal error for controllers with DHRIO modules configured for DH+/DH+ (20352)
Upload fails in some configurations of DHRIO modules (20429)
Module descriptions lost on upload/merge (20071)
Can not upload program from a busy controller (19865)
Cross reference of unverified and typeless tags (19680)
Focus problem prevented search from finding any occurrences (19668)
General Fault Type of motion group not being exported (19217)
Cross reference view updates are slow for large number of references (19149)
Operand comments lost on ASB size change (19130)
Rack optimized tag comments lost after export and re-import (19127)
Online rung edit causes application Fatal Error (18927)

Logix5550
Refer to the Firmware Release Notes for the Logix5550 Controller (Publication 1756-10.1-RN1 - October 1999) to review the most significant problems that have been
fixed.

Known Anomalies
Keep the following safety concerns/limitations in mind when using these releases.

Version 13.00.00
MCCM Coordinated Motion Instruction When Specifying a 180-Degree Arc
Creating or Importing Immediate Output (IOT) Instruction with Literal Value Causes Fatal Error
Motion SERCOS Ring Phase Up Issue If Auxiliary Feedback Units Aux_Mm Or Aux_Inch
Motion Group Configfault Bit Only Cleared If Motion Task Starts
Unable to Perform FBD Routine Pending Edits in Hard Run or Controller Locked Modes
Re-aliasing Tags in FBD Input References May Cause Fatal Error During Download
No Online Help Available for Certain RSTrendX Properties Tabs
Database Conversion Issue With AXIS_SERVO_DRIVE Type Tags for Attributes DCBusVoltage, TorqueLimitSource, and SERCOSRingFault
Displaying Secondary Online Help Window May Cause Blank Primary Window
Possible Project Corruption for 1336 Plus II Drive
Structured Text and Project Component References
Structured Text Editor Does Not Support REAL#NNN.NN Format
SFC Wire Routing in Sequence Loops
Copy/Paste of SFC Elements Displays Incorrect Error Message
FBD Subroutine Instructions (JSR/SBR/RET) and Duplicate Parameters
Project Re-Verification Operations
PowerFlex Drives with DPI Connections
Error Accessing Motion Module Properties After Import
Runtime Error Opening Trend Chart Properties
Output Cam Execution Targets not converted
DH485 Message Size Limit
DH485 Protocol limited to baud rate of 19,200
Produce and Consume tag changes
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Programming over a DF1 Master/Slave network

Download fails with communication time-out


User-defined data type size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Uploading controllers with multiple aliases to the same data

Version 12.03.00/12.02.00/Version 12.01.00/Version 12.00.00


ControlLogix Redundancy Support
Label (LBL) Instruction
Database Conversion Issue with AXIS_SERVO_DRIVE Type Tags for Attributes DCBusVoltage, TorqueLimitSource, and SERCOSRingFault
Error Going Online to Unsupported Controller
SFC Transition Elements Containing Ambiguous Jump to Subroutine Instructions
Displaying Secondary Online Help Window May Cause Blank Primary Window
Possible Project Corruption for 1336 Plus II Drive
Structured Text and Project Component References
Structured Text Editor Does Not Support REAL#NNN.NN Format
SFC Wire Routing in Sequence Loops
Copy/Paste of SFC Elements Displays Incorrect Error Message
Sending CIP Generic Messages Over ControlNet
FBD Subroutine Instructions (JSR/SBR/RET) and Duplicate Parameters
Project Re-Verification Operations
Drive Interface Modules Comm Format Support
PowerFlex Drives with DPI Connections
Replacing Tag Names That Include Underscores
Error Accessing Motion Module Properties After Import
Runtime Error Opening Trend Chart Properties
Output Cam Execution Targets not converted
DH485 Message Size Limit
DH485 Protocol limited to baud rate of 19,200
Produce and Consume tag changes
Online correlation failure accepting a large number of pending edits

Tag Editor/Data Monitor Expand All with large arrays


Unable to uninstall RSLogix 5000 when disk space is low
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Uploading controllers with multiple aliases to the same data

Version 11.13.00/Version 11.12.00/Version 11.11.00/Version 11.10.00


Online Editing Ladder Logic Routines in the 1756-L63 Controller
Multiple Revision Support with V11.10 and V10.00
Structured Text and Project Component References
SFC Step Alarm Enable Attribute Operation
Structured Text Editor Does Not Support REAL#NNN.NN Format
Canceling Download May Not Clear Controller Memory with SFC Routines
SFC Wire Routing in Sequence Loops
Copy/Paste of SFC Elements Displays Incorrect Error Message
Sending CIP Generic Messages Over ControlNet
FBD Subroutine Instructions (JSR/SBR/RET) and Duplicate Parameters
Project Re-Verification Operations
Importing a V10.00 .L5K File and Changing the Revision to V11
Fatal Error Closing Module Properties After Changing Controller Types
PowerFlex Drives with DPI Connections
Drive Interface Modules Comm Format Support
Secondary Online Help Pop-up Topics Cause Windows Help Error
Replacing Tag Names That Include Underscores
Error Accessing Motion Module Properties After Import
Runtime Error Opening Trend Chart Properties
Output Cam Execution Targets not converted
DH485 Message Size Limit

DH485 Protocol limited to baud rate of 19,200


Produce and Consume tag changes
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing

Version 10.04.00/Version 10.03.00/Version 10.02.00/Version 10.00.00


Online Editing Ladder Logic Routines in 1756-L63 Controller
Multiple Revision Support with V11.10 and V10.00
Replacing Tag Names That Include Underscores
Error Accessing Motion Module Properties After Import)
Unsynchronized Messages to the Same Module Via ControlNet
Produced/Consumed Tag Problems After Changing the Size of a User-Defined Type
Runtime Error Opening Trend Chart Properties
Output Cam Execution Targets not converted
DH485 Protocol limited to baud rate of 19,200
Increasing array dimension for structure data type tags resets data values
Produce and Consume tag changes
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data type size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion instruction data type size change

Failure to modify the RPI of a consumed tag


Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Uploading controllers with multiple aliases to the same data

Version 9.00.00
Controller memory changes
Import/Export Version has changed to 2.0
Indirect addressing of an ASCII string
Output Cam Execution Targets not converted in V9.00.00
Downloading a project which changes the CST master
DH485 Protocol limited to baud rate of 19,200
Increasing array dimension for structure data type tags resets data values
Produce and Consume tag changes
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data type size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Uploading controllers with multiple aliases to the same data

Version 8.52.00
Nonvolatile Memory and Motion Restrictions in Redundancy Systems
Controller memory changes
Import Export Version has changed to 1.1
Indirect Addressing of an ASCII String
Downloading a project which changes the CST master

DH485 Protocol limited to baud rate of 19,200


Increasing array dimension for structure data type tags resets data values
Unable to calibrate modules on FlexLogix Local Bus
1794-VHSC module support restrictions
Produce and Consume tag changes
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Older version .L5K files with 1794-IB10X0B6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data type size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Uploading controllers with multiple aliases to the same data

Version 8.02.00
RSLogix 5000
Controller memory changes
Additional memory to upgrade to firmware revision 8.x
Downloading a project which changes the CST master
DH485 Protocol limited to baud rate of 19,200
Increasing array dimension for structure data type tags resets data values
Unable to calibrate modules on FlexLogix local bus
1794-VHSC module support restrictions
Produce and Consume tag changes
Import Version has changed to 1.1
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits

Tag Editor/Data Monitor Expand All with large arrays


Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading controllers that reconfigure the DF1 port
Uploading controllers with multiple aliases to the same data

Version 8.00.00
RSLogix 5000
Controller memory changes
Additional memory to upgrade to firmware revision 8.x
Import fails for 1756-DHRIO/C module with Major Revision 4
Forcing of SynchLink DirectData bits disrupts CST
Changing consumed DINT tag to AXIS type my install forced bits
Changing CST Master from controller to 1756-SYNCH clears axis data
Unable to calibrate modules on FlexLogix local bus
1794-VHSC module support restrictions
Avoid using BOOL arrays in a User-Defined Data Type
Produce and Consume tag changes
Import Version has changed to 1.1
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers

Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading controllers that reconfigure the DF1 port
Uploading controllers with multiple aliases to the same data

Version 7.02.00
RSLogix 5000
Controller Memory Changes
1794-VHSC Module Support Restrictions
Avoid using BOOL arrays in a User-Defined Data Type
Produce and Consume tag changes
Import Version has changed to 1.1
Import changes out of range values for data type REAL, or stops for data types SINT, INT, and DINT
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash

Instances of going online for the first time failing


Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 7.00.00
RSLogix 5000
Avoid using BOOL arrays in a User-Defined Data Type
Produce and Consume tag changes
Import Version has changed to 1.1
Import changes out of range values for data type REAL, or stops for data types SINT, INT, and DINT
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 6.03.00
RSLogix 5000
Import Version has changed to 1.1
Import changes out of range values for data type REAL, or stops for data types SINT, INT, and DINT
Corrupt Cam or Cam Profile data causes fatal error

Converting projects containing the 1794-IB16/A module


Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 6.01.00
RSLogix 5000
Import Version has changed to 1.1
Import changes out of range values for data type REAL, or stops for data types SINT, INT, and DINT
Corrupt Cam or Cam Profile data causes fatal error
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change

Failure to modify the RPI of a consumed tag


Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 6.00.00
RSLogix 5000
Import Version has changed to 1.1
Import changes out of range values for data type REAL, or stops for data types SINT, INT, and DINT
Corrupt Cam or Cam Profile data causes fatal error
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 5.02.00
RSLogix 5000
Import Version has changed to 1.2
Downloading to other V5.xx processors

MGS instruction modification


FlexLogix and SoftLogix controllers not supported
Use with Windows 2000 not supported
Electronic keying of SERCOS Drive modules can fail
Deleting Drive module without unassociating axes first can cause some configuration data not to be downloaded
Absolute homing machine offset not supported
Logix5555 controller not supported
Import changes out of range values for data type REAL, or stops for data types SINT, INT, and DINT
Corrupt Cam or Cam Profile data causes fatal error
Converting projects containing the 1794-IB16/A module
Online correlation failure accepting a large number of pending edits
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers or with PLC-5 controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 2.51.00
RSLogix 5000
Upload fails after rescheduling ControlNet network
Unexpected disconnection when forcing slot status bits in a rack optimized input image
Converting projects containing the 1794-IB16/A module
Consumed tags based on User-defined data types
Localized language installation may leave trending components

RSLogix 5000 locks up while copying modules


Online correlation failure accepting a large number of pending edits
FLEX I/O Listen-only connections
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import
Multi-controller configurations that share FLEX I/O with PLC-5 controllers
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Using large programs and/or large data table arrays with workstations with less than 64 Mb of RAM
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 2.50.00
RSLogix 5000
Unexpected disconnection when forcing slot status bits in a rack optimized input image
Converting projects containing the 1794-IB16/A module
Consumed tags based on User-defined data types
Localized language installation may leave trending components
RSLogix 5000 locks up while copying modules
Online correlation failure accepting a large number of pending edits
FLEX I/O Listen-only connections
Tag Editor/Data Monitor Expand All with large arrays
Unable to uninstall RSLogix 5000 when disk space is low
Multi-controller configurations that share FLEX I/O among ControlLogix controllers
Older version .L5K files with 1794-IB10XOB6 modules will not import

Multi-controller configurations that share FLEX I/O with PLC-5 controllers


Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types size limits
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Using large programs and/or large data table arrays with workstations with less than 64 Mb of RAM
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Instances of going online for the first time failing
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 2.27.00
RSLogix 5000
Cannot assign module to position-only axis
User-Defined Type with more than 512 members causes Fatal Error
Multi-controller configurations that share FLEX I/O among ControlLogix controllers
Valid configurations can be rejected in FLEX I/O
Multi-controller configurations that share FLEX I/O with PLC-5 controllers
FLEX I/O Listen-only connections
FLEX Adapter fails after many connection losses
Special characters in .CSV file may fail to import
Tag Editor Expand All with large arrays
RSLogix 5000 locks up while copying modules
Unable to uninstall RSLogix 5000 when disk space is low
Shared FLEX I/O modules may overwrite configuration
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types larger than 64Kb
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change

Failure to modify the RPI of a consumed tag


Using large programs and/or large data table arrays with workstations with less than 64 Mb of RAM
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Online Run mode edits to MSG messages
Instances of going online for the first time failing
Produce-Consume of data from a PLC-5C processor
Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 2.25.00
RSLogix 5000
User-Defined Type with more than 512 members causes Fatal Error
Multi-controller configurations that share FLEX I/O among ControlLogix controllers
Valid configurations can be rejected in FLEX I/O
Multi-controller configurations that share FLEX I/O with PLC-5 controllers
FLEX I/O Listen-only connections
FLEX Adapter fails after many connection losses
Special characters in .CSV file may fail to import
Tag Editor Expand All with large arrays
RSLogix 5000 locks up while copying modules
Unable to uninstall RSLogix 5000 when disk space is low
Shared FLEX I/O modules may overwrite configuration
Older version .L5K files with 1794-IB10XOB6 modules will not import
Programming over a DF1 Master/Slave network
Download fails with communication time-out
User-defined data types larger than 64Kb
Program-scoped tag aliased to controller-scoped tag with the same name
Motion_Instruction data type size change
Failure to modify the RPI of a consumed tag
Using large programs and/or large data table arrays with workstations with less than 64 Mb of RAM
Wall Clock Time beyond January 17, 2038 causes RSLogix 5000 to crash
Online Run mode edits to MSG messages
Instances of going online for the first time failing

Produce-Consume of data from a PLC-5C processor


Downloading processors that reconfigure the DF1 port
Uploading processors with multiple aliases to the same data

Version 1.20.00
RSLogix 5000
Instances of going online for the first time failing
Processors with motion control
Destination operands for GSV commands
Setting the date in the controller via the SSV command
Logix5550 supports only one RSLogix 5000 session at a time
Downloading controllers that use more memory than available
CIP data table messaging with user-defined data types
Consume of user-defined data types
Produce-Consume of data from a PLC-5 processor
Uploading programs that consume PLC-5C data
Creating user-defined data types
Downloading processors that reconfigure the DF1 port
Changing the servo type online for an unconfigured module
Multiple owners and/or listeners of analog modules
Online Run mode edits to block transfer type messages
Uploading processors with multiple aliases to the same data
Screen resolution at 640 x 480
Keyboard navigation
Cross reference sorting
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Converting programs with Listen Only Rack Optimized connections from Version 1.10.00
Using unsolicited messaging from ControlLogix5550 to RSLinx
Using large programs and/or large data table arrays with workstations with less than 64 Mb of RAM

Setting timer/counter presets beyond the maximum allowable range


Making backups of controller files
RSNetWorx and RSLogix 5000 Version 1.11 and earlier incompatibility

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the ControlLogix processor
RSWho in autobrowse with analog modules

Version 1.10.00
RSLogix 5000
Instances of going online for the first time failing:
Processors with motion control:
Using aliases in GSV/SSV instructions:
Destination operands for GSV commands:
Setting the date in the controller via the SSV command:
Drag and drop of motion (1756-M02AE) modules:
Logix5550 supports only one RSLogix5000 session at a time:
Interrupting processor power during a download:
Downloading controllers that use more memory than available:
CIP Datatable messaging with user-defined data types:
Consume of user-defined data types:
Produce Consume of data from a PLC-5C processor:
Producing data from a Logix5550 and consuming in a PLC-5C processor:
Uploading programs that consume PLC-5C data:
Creating user-defined data types:
Downloading processors that reconfigure the DF1 port:
Import and export of applications with Module defined types in User-defined types:
Caution using multiple controllers in the same chassis:
Changing the servo type online for an unconfigured module:
Stopping calibration of analog modules:
Multiple owners and/or listeners of Analog modules:

Online Run mode edits to block transfer type messages:


Uploading processors with multiple aliases to the same data:
Identically named program and controller scoped tags:
Using keyboard selection of Show Instructions by Group:
Utilizing cross-reference to a subroutine name:
Screen resolution at 640 X 480:
Keyboard navigation:
Upgrading RSLogix 5000 projects from prior versions of Logix5550 firmware and RSLogix 5000:
Cross reference sorting:
Configuring the DHRIO module:
Using Series-A DHRIO modules:
User disk memory utilization:
Mapping to remote/network drives:
Using wall clock time:
Offline/Online changes to I/O configuration:
Using the message Time out bit:

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module.
Configuring DF1 drivers:
DDE interface to the ControlLogix processor:
RSWho in autobrowse with analog modules:

Application Notes
Version 13.00.00
RSLogix 5000
RSLogix 5000 Enterprise Series (Multiple Revision Support)
Sequential Function Charts Reset to Initial Step During Online Editing
RSLogix 5000 Appears to Lock Up When RSMACC Connection Broken
RSLogix 5000 Save May Result in Large Project .ACD File
Activation Error Running Multiple Versions Simultaneously
Default Project Directory and Windows 2000/XP
FBD Routine Localized Feedback Wiring Errors
FBD Routine Order of Execution for Unwired Blocks
Motion Module Servo Update Period Changed
Motion Group Fault No Longer Produces Major Fault in Program Mode
Updating Controller Firmware in a DH485 Network
Online disconnection after nonvolatile Store or Load operation
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Configuring the DHRIO module
User disk memory utilization
Mapping to remote/network drives
Offline/Online changes to I/O configuration
Application errors at end of install or at RSLogix 5000 startup on some systems

RSLinx with RSLogix 5000


Configuring the Ethernet Port on a CompactLogix5532E
RSLinx Professional Activation
Accessing Structures Larger Than 64 Kbytes
Configuring drivers for the 1756-ENET, 1756-ENBT, and 1756-EWEB modules
Configuring DF1 drivers
Offline Tag and UDT Changes Downloaded to the Controller May Cause RSLinx (2.X) to Halt Communications

Version 12.03.00/12.02.00/Version 12.01.00/Version 12.00.00


RSLogix 5000
RSLogix 5000 Appears to Lock Up When RSMACC Connection Broken
Reserved Keywords Should Not Be Used in RSLogix 5000 Object Names
RSLogix 5000 Save May Result in Large Project .ACD File
Activation Error Running Multiple Versions Simultaneously
Default Project Directory and Windows 2000
FBD Routine Localized Feedback Wiring Errors
FBD Routine Order of Execution for Unwired Blocks
Motion Module Servo Update Period Changed
Updating Controller Firmware in a DH485 Network
Online disconnection after nonvolatile Store or Load operation
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Configuring the DHRIO module
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx
RSLinx Professional Activation
RSLinx/RSView Offline Tag Access
Accessing Structures Larger Than 64 Kbytes
Configuring drivers for the 1756-ENET module
Configuring DF1 drivers
DDE interface to the Logix5550 controller

Version 11.13.00/Version 11.12.00/Version 11.11.00/Version 11.10.00


RSLogix 5000
Reserved Keywords Should Not Be Used in RSLogix 5000 Object Names
RSLogix 5000 Save May Result in Large Project .ACD File
Activation Error Running Multiple Versions Simultaneously
Default Project Directory and Windows 2000
FBD Routine Localized Feedback Wiring Errors
FBD Routine Order of Execution for Unwired Blocks
Motion Module Servo Update Period Changed
Updating Controller Firmware in a DH485 Network
Online disconnection after nonvolatile Store or Load operation
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Configuring the DHRIO module
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx
RSLinx Professional Activation
RSLinx/RSView Offline Tag Access
Accessing Structures Larger Than 64 Kbytes
Configuring drivers for the 1756-ENET module
Configuring DF1 drivers
DDE interface to the Logix5550 controller

Version 10.04.00/Version 10.03.00/Version 10.02.00/Version 10.00.00


RSLogix 5000
Activation Error Running Multiple Versions Simultaneously
Default Project Directory and Windows 2000
FBD Routine Localized Feedback Wiring Errors
FBD Routine Order of Execution for Unwired Blocks
Motion Module Servo Update Period Changed
Updating Controller Firmware in a DH485 Network
Online disconnection after nonvolatile Store or Load operation
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Configuring the DHRIO module
User disk memory utilization
Mapping to remote/network drives
Offline/Online changes to I/O configuration
Application errors at end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


RSLinx Professional Activation

RSLinx/RSView Offline Tag Access


Accessing Structures Larger Than 64 Kbytes
Configuring drivers for the 1756-ENET module
Configuring DF1 drivers
DDE interface to the Logix5550 controller

Version 9.00.00
RSLogix 5000
Online disconnection after nonvolatile Store or Load operation
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Configuring the DHRIO module
User disk memory utilization
Mapping to remote/network drives
Offline/Online changes to I/O configuration
Application errors at end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Accessing Structures Larger Than 64 Kbytes
Configuring drivers for the 1756-ENET module
Configuring DF1 drivers
DDE interface to the Logix5550 controller

Version 8.52.00
RSLogix 5000
Online disconnection after nonvolatile Store or Load operation

Communication Program and Fault modes not supported for 1769 output modules
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Configuring the DHRIO module
User disk memory utilization
Mapping to remote/network drives
Offline/Online changes to I/O configuration
Application errors at end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Unable to Monitor Data on a Secondary Controller
Accessing Structures Larger Than 64 Kbytes
Configuring drivers for the 1756-ENET module
Configuring DF1 drivers
DDE interface to the Logix5550 controller

Version 8.02.00
RSLogix 5000
Online disconnection after nonvolatile Store or Load operation
Communication Program and Fault modes not supported for 1769 output modules
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules

Screen resolution at 640 x 480


Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files
RSLinx with RSLogix 5000
Accessing Structures Larger Than 64 Kbytes
Configuring drivers for the 1756-ENET module
Configuring DF1 drivers
DDE interface to the Logix5550 controller

Version 8.00.00
RSLogix 5000
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Controllers with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files
DDE/OPC Access to V8.x Controller Data
Accessing Structures Larger Than 64 Kbytes

Configuring drivers for the 1756-ENet module


Configuring DF1 drivers

RSLinx with RSLogix 5000


DDE interface to the ControlLogix controller

Version 7.02.00
RSLogix 5000
I/O module list appears empty
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor

Version 7.00.00
RSLogix 5000
I/O module list appears empty

Configuring CRC error detection for RSLogix 5000 software


Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files
RSLinx with RSLogix 5000
Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor

Version 6.03.00
RSLogix 5000
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration

Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor

Version 6.01.00
RSLogix 5000
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor

Version 6.00.00
RSLogix 5000
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor

Version 5.02.00
RSLogix 5000
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module

Using Series-A DHRIO modules


User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files
RSLinx with RSLogix 5000
Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor

Version 2.51.00
RSLogix 5000
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor
Driver Name restrictions in the ControlLogix Gateway Version 1.9 software (Cat. No. 1756-GTWY)

Version 2.50.00
RSLogix 5000
Configuring CRC error detection for RSLogix 5000 software
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Downloading controllers that use more memory than available
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor
Driver Name restrictions in the ControlLogix Gateway Version 1.9 software (Cat. No. 1756-GTWY)

Version 2.27.00
RSLogix 5000
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Logix5550 supports only one RSLogix 5000 session at a time
Downloading controllers that use more memory than available
Conversion of projects from older software versions
Multiple owners and/or listeners of 1756 analog modules

Screen resolution at 640 x 480


Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor
Driver Name restrictions in the ControlLogix Gateway Version 1.9 software (Cat. No. 1756-GTWY)

Version 2.25.00
RSLogix 5000
Changes in Fatal Error handling
Processors with motion control
Destination operands for GSV commands
Logix5550 supports only one RSLogix 5000 session at a time
Downloading controllers that use more memory than available
Conversion of projects from older software versions
Multiple owners and/or listeners of 1756 analog modules
Screen resolution at 640 x 480
Configuring the DHRIO module
Using Series-A DHRIO modules
User disk memory utilization
Mapping to remote/network drives
Offline/online changes to I/O configuration
Application errors at the end of install or at RSLogix 5000 startup on some systems
Making backups of controller files

RSLinx with RSLogix 5000


Configuring drivers for the 1756-ENet module
Configuring DF1 drivers
DDE interface to the Logix5550 processor
Driver Name restrictions in the ControlLogix Gateway Version 1.9 software (Cat. No. 1756-GTWY)

Contact Information
For technical assistance, please use the following contacts:
Technical Support Telephone - 440-646-5800
Technical Support Fax - 440-646-5801
World Wide Web - http://support.automation.rockwell.com

When you call


When you call, you should be at the computer running the Rockwell Software product and be prepared to provide the following information:
the product serial number on the Activation disk labels
You can find the serial number online. On the RSLogix 5000 menu, click Help, and then click About.
the product version number
This information also appears in the About box.
the hardware you are using
the exact wording/exact error codes of any messages that appear on the screen
a description of what happened, and what you were doing when the problem occurred
a description of how you tried to solve the problem

Trademark Information
WINtelligent Series is a registered trademark, and the Rockwell Software logo, RSAlarm, RSAnimator, RSAssistant, RSBatch, RSBreakerBox, RSButton, RSChart,
RSCompare, RSControlRoom, RSData, RSDataPlayer, RSEventMaster, RSGuage, RSJunctionBox, RSLogix Emulate 5, RSLogix Emulate 500, RSGuardian,
RSHarmony, RSKeys, RSLadder, RSLadder 5, RSLadder 500, RSLinx, RSLogix 5, RSLogix 500, RSLogix 5000, RSLogix Frameworks, RSMailman, RSNetWorx for
ControlNet, RSNetWorx for DeviceNet, RSPortal, RSPower, RSPowerCFG, RSPowerRUN, RSPowerTools, RSRules, RSServer32, RSServer, RSServer OPC Toolkit,
RSSidewinderX, RSSlider, RSSnapshot, RSSql, RSToolbox, RSToolPak I, RSToolPak II, RSTools, RSTrainer, RSTrend, RSTune, RSVessel, RSView32, RSView,
RSVisualLogix, RSWheel, RSWire, RSWorkbench, RSWorkshop, SoftLogix 5, A.I. Series, Advanced Interface (A.I.) Series, AdvanceDDE, ControlGuardian,
ControlView, INTERCHANGE, Packed DDE, WINtelligent, WINtelligent LINX, WINtelligent LOGIC 5, WINtelligent VIEW, WINtelligent RECIPE, WINtelligent
VISION, and WINtelligent VISION2 are trademarks of Rockwell Software Inc.
PLC, PLC-2, PLC-3 and PLC-5 are registered trademarks, and Data Highway Plus, DH+, DHII, DTL, MicroLogix, Network DTL, PowerText, Pyramid Integrator,
PanelBuilder, PanelView, PLC-5/250, PLC-5/20E, PLC-5/40E, PLC-5/80E, SLC, SLC 5/01, SLC 5/02, SLC 5/03, SLC 5/04, SLC 5/05, SLC 500, and ControlLogix
are trademarks of the Allen-Bradley Company, Inc.
Microsoft, MS-DOS, Windows, and Visual Basic are registered trademarks, and Windows NT, Windows 2000, and Microsoft Access are trademarks of the Microsoft
Corporation.
ControlNet is a trademark of ControlNet International.
Ethernet is a registered trademark of Digital Equipment Corporation, Intel, and Xerox Corporation.
IBM is a registered trademark of International Business Machines Corporation. AIX, PowerPC, Power Series, RISC System/6000 are trademarks of International
Business Machines Corporation.
UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company Limited.
AutoCAD is a registered trademark of Autodesk, Inc.
All other trademarks are the property of their respective holders and are hereby acknowledged.

You might also like