3ADW000165R0201_Technical_Data_e_b
DCS 400
DCS 500B
DCS 600
DCF 500B
DCF 600
Operating Instructions
3ADW000055
3ADW000080
3ADW000091 (Installation)
EN,DE,FR,SP
EN, DE
EN, DE
Software description
3ADW000078
3ADW000076
3AST000953
EN
EN
EN
Tools
3AFE61178775 CMT/DCS500
EN 5926915-1 GAD
3ADW000048 (Application blocks)
3AFY61296123 Drive Window
EN
EN
EN
EN
Service Instructions
3ADW000093
3ADW000131
EN, DE
EN
Fieldbus
3ADW000086
3ADW000097
EN
EN
Others
3ADW000115 12-Pulse operation
3ADW000092 Rebuild manual
3ADW000128 Paralleling DCS Conv.
3ADW000040 12-Puls operation
Language
Language
Language
Language
Language
Language
Language
EN
EN
EN
EN, DE
DCR
DCS/DCF 500B
DCS 400
x
x
x
x
Rebuild
Module
x
x
x
x
x
x
Volume
III
Volume
IV A
IV F
IV F1
Volume
V D1
VF
Volume
V A2
-
Volume
VI A
VI K
Volume
-
Volume
VIII F2
XI H1
VIII D1
VIII A2
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
EN
Volume
II D
II F
II F1
II K
II F
Cubicle
Technical Data
3ADW000165
Language
Standard Drive
Module
EN, DE,FR
EN, DE
EN
EN,DE,FR,IT,SP
EN
EN, DE
EN, DE,FR,IT,SP
EN
DCA 620
Product documentation
System description
3ADW000066
3ADW000072
3ADW000121
3ADW000095 (Manual)
3ADW000139
3ADW000071 (Flyer)
3ADW000152
3ADW000173 (Flyer)
DCA 600
Cubicle
DCE 400
System Drive
DC drive systems
x
x
x
x
x
3ADW000165R0201_Technical_Data_e_b
Status: 25.March.2002
III ii
x
x
x
x
Contents
III 1-2
III 1-3
III 1-4
III 1-5
III 1-6
III 8-1
III 8-2
III 8-4
III 8-9
III iii
3ADW000165R0201_Technical_Data_e_b
III iv
3ADW000165R0201_Technical_Data_e_b
Quick Guide
General remarks
The term DCS thyristor power converter is a general designation for basic DC converters from ABB. This term
can be found in many parts of the relevant documentation. The precise product name in accordance with the
brief descriptions given below characterizes a specific unit.
Brief description of DCS 500B
The DCS 500B unit range is an enhancement developed from the DCS 500 range.
The DCS 500B is an armature converter with the following standard features:
Design and commissioning tools Monitoring functions Communication via databus Human-machine
interface More than 300 additional functions blocks programmable under Windows Graphical Application Designer Plain text display FOR HIGH POWER
Brief description of DCF 500B
With software release 21.232 or higher DCS 500B has a '3-phase field exciter mode'. A DCF 500B is a threephase field exciter based on the programmable DCS 500B software and the SDCS-CON-2 control board.
The interface board PIN-1x is modified; - an overvoltage protection unit DCF 505/506 is required.
Brief description of DCS 600
The DCS 600 converter family is based on the hardware developed for the DCS 500B type.
Instead of a COM-x board, the SDCS_AMC_DC board is used. PC tools will be connected there, as well as
the APC (Application controller), if the APC is used as a PLC. If a different PLC is used, separate adapter
modules are needed. They must be connected to the AMC-DC board, too. The software code always begins
with S15.xxx for MultiDrive or S18.xxx for Crane drives.
Brief description of DCF 600
The DCF 600 unit range is intended to be used for supplying motor fields and is based on the hardware and
system configuration of the DCS 600 unit. The software is identical to the DCS 600 software. Similar to DCF
500B units the DCF 505/506 overvoltage protection unit is required. The same modification is applied to the
PIN-1x board, compared to DCF 500B.
Brief description of DCS 400
The DCS 400 is the smallest drive in its class. The compact design has been partly achieved by a fully integrated
field exciter based on IGBT technology. A commissioning wizard - available on the control panel and the PC
tool - makes start-up of the drive easy. In addition, the DCS 400 contains application macros.
III 1-1
3ADW000165R0201_Technical_Data_e_b
III 1-2
3ADW000165R0201_Technical_Data_e_b
optical fibre
8
PS5311 6.2
IOB 3
6.2
X16: X14:
X13:
X12:
X37:
IOE 1
6.3
PIN 51
5.4
PIN 20x
5.2
PIN 1x
5.1
POW 1
4.1
PIN 41 5.4
PIN 41 5.4
9.1
L1
K1
FEX 1
8.1
Legend
FEX 2
8.2
9.2
L3
8.3
8.4
Power
supply
to field
7.1
K5
K3
T3
F3
IOB 2x
6.1
X17:
CON 2
3.1
Q1
F1
Field bus
to the PLC
8
4
X1: X2:
X33:
X11:
DCS 50.B....-.1-21.....
9.3
T2
F2
Earth-fault monitor
EMC filter
Field Bus
Adapter
Module
Nxxx
7
3
+24 V
optical fibre
CDP 312
COM 5
7.1
SNAT 6xx
PC +
CMT/DCS500
690V
1000V
optical fibre
3ADW000165R0201_Technical_Data_e_b
III 1-3
8
IOB 2x
6.1
X17:
X13:
X12:
X37:
IOB 3
6.2
5.6
PS5311 6.2
X16:
CON 2
3.1
IOE 1
6.3
PIN 1x
5.1
ied
dif
o
m
PIN 20x
5.2
POW 1
4.1
9.3
T2
F2
9.1
L1
K3
F1
Q1
Legend
to a digital input
of DCF 500B
8.4
7.1
K5
Earth-fault monitor
EMC filter
DCF 506
Field bus
to the PLC
Field Bus
Adapter
Module
Nxxx
8
4
X1: X2:
X33:
X11:
DCF 50.B....-.1-21.....
CZD-0x
7
3
+24 V
optical fibre
CDP 312
COM 5
7.1
SNAT 6xx
PC +
DDC-Tool
690V
500V
PC +
to other drives
III 1-4
3ADW000165R0201_Technical_Data_e_b
to the PLC
X99
- Master/
Follower
X17
X1
X14
X4,5 X6
IOB 2x
6.1 X3
X16
X13
X12
X37
X2
X1
X3 X5
IOB 3
6.2
X2
6.2
PIN 51
X13 5.4
X12
C1 D1
U1 V1 W1
A92
PIN 41 5.4
X17
5.3
PIN 41 5.4
IOE 1
6.3
X2 X1
PIN 20xB
X13 5.2
X12
PS5311
X4 X3
X1
POW 1
4.1
PIN 1x
X13 5.1
X12
X37
T90
9.1
L1
K1
F1
Q1
X1
X14
FEX 1
8.1
X1
L3
X1
Legend
X1
X14
FEX 2
8.2
9.2
8.3
U1 V1
C1 D1
7.1
8.4
C1 D1
dcs6_sys_h.dsf
Power
supply
U1 V1 W1
K5
K3
T3
F3
DCF 503A
/ 504A
X2
Field Bus
Adapter
Module
Nxxx
X1 X2
X11
3.1
CON 2
X33
V260
X16
(24V)
X10
12-Pulse link
9.3
X3
X3
M onitoring
LED bar
NLM D
T2
F2
X16
8
4
CH2
DSP
CH0
AMC-DC
CH3
7.2
X2
Rev D or later
Panel
CDP 312
MultiDrive
socket
NDPI
Earth-fault monitor
EMC filter
PLC
-Advant
control
7
3
7.3
NDBU95
-NDPA-02
(PCMCIA)
-NDPC-12
-NISA-03 (ISA)
DriveWindow
690V
1000V
7
3
3ADW000165R0201_Technical_Data_e_b
to other drives
III 1-5
X1
X14
X4,5 X6
IOB 2x
6.1 X3
X16
V260
to the PLC
- Master/
Follower
X17
X13
X12
X37
X1
X4 X3
5.6
IOB 3
6.2
X2
X17
X2 X1
7
IOE 1
6.3
PIN 1x
5.1
ied
dif
mo
PIN 20xB
X13 5.2
X12
X13
X12
POW 1
4.1
X37
X99
C1 D1
U1 V1 W1
9.1
L1
K3
7.1
X11
X12
Legend
C1 D1
8.4
X4
dcf6_sys_i.dsf
K5
X16
Field Bus
Adapter
Module
Nxxx
X1 X2
X11
CON 2
3.1
CZD-0x
X16
(24V)
X10
X33
DCF 6..-....-.1-15.....
X3
9.3
Q1
F1
DCS 600
8
4
CH2
DSP
CH0
AMC-DC
CH3
7.2
X2
X3
Monitoring
LED bar
NLM D
T2
F2
Earth-fault monitor
EMC filter
DCF 506
PLC
-Advant
control
7.3
NDBU95
Panel
CDP 312
-NDPA-02
(PCMCIA)
-NDPC-12
-NISA-03 (ISA)
Rev D or later
MultiDrive
socket
NDPI
PC +
DriveWindow
690V
500V
RS232
optical fibre
III 1-6
3ADW000165R0201_Technical_Data_e_b
4
8
2
Inputs / Outputs
115...230 V AC
Field
control
Thyristor
control
SDCS-PIN-3A
Power
Supply
Legend
115 / 230 V AC
Serial
interfaces
Remark:
All detailed information about the DCS 400 DC drive you can only find in the DCS 400
Manual (documentation no. 3ADW 000 095).
dcs4_sys_c.dsf
L1
K1
F1
Q1
EMC filter
Field supply
SDCS-FIS-3A
Field bus
to the PLC
Field Bus
Adapter
Module
Nxxx
DCS 400
Control electronics
SDCS-CON-3A
Control panel
DCS400PAN
PC +
Tool or
PLC
230...500V
Converter modules
L1 L2 L3
F1x
F1x
F1x
F1x
F1x
F1x
DCS 500 / DCS 500B / DCS 600 / DCF 500B / DCF 600
Unit range type DCF 500B and DCF 600 for output current of up to max. 520 A available
2.1
2.2
2.3
2.4
2.5
Note:
For clearness the type designation
in this chapter is shown in the following way:
Designation
is valid for
DCS 500
DCS 500B
DCS 600
DCF 500B
DCF 600
III 2-1
3ADW000165R0201_Technical_Data_e_b
2.1
Dimensions
DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600
Module C1
DCS 50x-0025
DCS 50x-0050
DCS 50x-0075
Dimensions in mm
Weight appr. 7.6 kg
Swinging radius
Center of hinge
(+)
(-)
250
Module C1
DCS 50x-0100
DCS 50x-0110
DCS 50x-0140
Dimensions in mm
Weight appr. 11.5 kg
Swinging radius
Center of hinge
(+)
(-)
III 2-2
3ADW000165R0201_Technical_Data_e_b
DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600
250
Module C2
DCS 50x-0200
DCS 50x-0250
DCS 50x-0270
DCS 50x-0350
Dimensions in mm
Weight appr. 22,8 kg
Swinging radius
Center of hinge
(-)
150
(+)
176 (0200/0250)
191 (0270/0350)
Busbars in mm: 25 x 3
Fig. 2.1/3: Dimension drawing C2-Module
250
Module C2
DCS 50x-0450
DCS 50x-0520
Dimensions in mm
Weight appr. 29 kg
Swinging radius
Center of hinge
(-)
150
(+)
Busbars in mm: 30 x 5
III 2-3
3ADW000165R0201_Technical_Data_e_b
250
Module C2
DCS 50x-0680
DCS 50x-0820
DCS 50x-1000
10
Dimensions in mm
Weight appr. 42 kg
Swinging radius
150
66
50
Center of hinge
M12
C2_680_b.dsf
Heat sink
U1
V1
C1
W1
Busbars in mm:
AC and DC 40 x 5
D1
150
press-in nut
Main Connections
at view from top
20
0
5
26
C2b_terminal_cover.dsf
Terminal cover
Fig. 2.1/5: Dimension drawing C2-Module
III 2-4
3ADW000165R0201_Technical_Data_e_b
400
450
125
V1
85.5
17 26
for M10
W1
17
26
14
Module A5
DCS 50x-0903
DCS 50x-1203
DCS 50x-1503
DCS 50x-2003
Dimensions in mm
Weight appr. 110 kg
34
773
775
820
1005
55
U1
125
22
127.5
250
510
Minimum Top
clearance
Support
Support
> 510
min. 480
69
D1
17.75
fan terminals
fan terminals
65.5
400
25
50
50
325.5
461
483
50
100
276
44.5
80
102
C1
cable tray
with = 40 mm
earthing height =39 mm
M12
Minimum
Bottom clearance
14
earthing M12
A5_dim_a.dsf
Busbars in mm:
DC 80 x 10
AC 60 x 5
Fig. 2.1/6: Dimension drawing A5-Module
III 2-5
3ADW000165R0201_Technical_Data_e_b
Module A6
DCS 50x-1903
DCS 50x-2053
DCS 50x-2503
DCS 50x-3003
20
250
Air outlet
409
10x20
Dimensions in mm
Weight appr. 180 kg C
200
D
225
M12
40
50
62
200
*
V
200
1725
1750
759.5
1079.5
63
10x20
Pressure switch
15
72
M10
385
445
100
Air entry
355
A6_dim.dsf
136
468.2
III 2-6
3ADW000165R0201_Technical_Data_e_b
~ 100
50
~ 100
50
50
Top view
air flow
air flow
air flow
Top view
air flow
air flow
air flow
A6_li_air_inlet.dsf
25
352
372
312
272
175
125
75
140
250
A6_cable_term_busb.dsf
D
do not unscrew this screws !
21.8
75
14
25
Cable entries
electronics power supply
100
72.2
control cables
pressure
converter fan
switch
(left and right side)
A6_li_air_inlet.dsf
max.
35mm
136
468.2
III 2-7
3ADW000165R0201_Technical_Data_e_b
230
for M10
350
200
25
Module A7
DCS 50x-2053 xxxL
DCS 50x-2603 xxxL
DCS 50x-3303 xxxL
DCS 50x-4003 xxxL
DCS 50x-4803 xxxL
DCS 50x-5203 xxxL
530
225
Dimensions in mm
Weight appr. 315 kg
200
1725
200
759.5
Pressure switch
for M10
80 80 80 80
93
A7_dim_a.dsf
Busbars in mm:
AC and DC 100 x 10
III 2-8
3ADW000165R0201_Technical_Data_e_b
Module A7
DCS 50x-2053 xxxR
DCS 50x-2603 xxxR
DCS 50x-3303 xxxR
DCS 50x-4003 xxxR
DCS 50x-4803 xxxR
DCS 50x-5203 xxxR
200
25
for M10
225
Dimensions in mm
Weight appr. 315 kg
759.5
Pressure switch
for M10
A7_dim_a.dsf
Busbars in mm:
AC and DC 100 x 10
III 2-9
3ADW000165R0201_Technical_Data_e_b
1725
200
200
air flow
air flow
Cable entries
The cable entries are existing symmetrically on both
sides. Nevertheless only the entries on the left side
should be used for cables going to the electronics
power supply (SDCS-POW-1) or the controller board
(SDCS-CON-x).
air
f lo
w
>20
Top view
50
III 2-10
3ADW000165R0201_Technical_Data_e_b
2.2
Converter type
400 V / 500 V
DCS 50x-1203-41/51
DCS 50x-1503-41/51
DCS 50x-2003-41/51
DCS 50x-2053-51
DCS 50x-2503-41/51
DCS 501-3003-41/51
DCS 502-3003-41/51
DCS 50x-3303-41/51
DCS 50x-4003-41/51
DCS 50x-5203-41/51
600 V / 690 V
DCS 50x-0903-61/71
DCS 50x-1503-61/71
DCS 501-2003-61/71
DCS 50x-2053-61/71
DCS 50x-2503-61/71
DCS 501-3003-61/71
DCS 502-3003-61/71
DCS 50x-3303-61/71
DCS 50x-4003-61/71
DCS 50x-4803-61/71
790 V
DCS 50x-1903-81
DCS 50x-2053-81
DCS 50x-2503-81
DCS 501-3003-81
DCS 502-3003-81
DCS 50x-3303-81
DCS 50x-4003-81
DCS 50x-4803-81
1000 V
DCS 50x-2053-91
DCS 50x-2603-91
DCS 50x-3303-91
DCS 50x-4003-91
Size
L1 L2 L3
Model
Fuse F1
Type
A5
A5
A5
A6
A6
A6
A6
A7
A7
A7
800A 660V UR
1250A 660V UR
1600A 660V UR
1500A 660V UR
900A 660V UR
1500A 660V UR
1250A 660V UR
2500A 660V UR
3000A 660V UR
3500A 660V UR
5
5
5
5
5
5
5
7
7
7
170M 6162
170M 6166
170M 6169
170M 6168
170M 6163
170M 6168
170M 6166
170M 7026
170M 7028
170M 7057
A5
A5
A5
A6
A6
A6
A6
A7
A7
A7
630A 1250V UR
1100A 1250V UR
1400A 1100V UR
700A 1250V UR
1000A 1250V UR
1100A 1250V UR
1000A 1250V UR
2500A 1000V UR
3000A 1000V UR
3000A 1000V UR
6
6
6
6
6
6
6
8
8
8
170M 6144
170M 6149
170M 6151
170M 6145
170M 6148
170M 6149
170M 6148
170M 7036
170M 7156
170M 7156
A6
A6
A6
A6
A6
A7
A7
A7
700A 1250V UR
700A 1250V UR
1000A 1250V UR
1100A 1250V UR
1000A 1250V UR
2500A 1000V UR
3000A 1000V UR
3000A 1000V UR
6
6
6
6
6
8
8
8
170M 6145
170M 6145
170M 6148
170M 6149
170M 6148
170M 7036
170M 7156
170M 7156
A7
A7
A7
A7
1800A 1250V UR
1800A 1250V UR
2500A 1250V UR
2500A 1250V UR
9
9
9
9
170M 7976
170M 7976
170M 7978
170M 7978
F1x
F1x
F1x
F1x
F1x
F1x
Size 5, 6
Size 7...10
Indicator
15
14
17
108
33
11
4xM10
min 10 deep
82.5
67.5
56
max 105
max d
11
max 105
max d
11
139
b
25
25
100
Size
5
6
a
50
80
b
29
14
c
30
30
d
76
76
Size
7
8
9
10
A
62
90
105
120
Remark:
Given dimensions may be exceeded in
some cases. Please take them only for
information.
III 2-11
3ADW000165R0201_Technical_Data_e_b
2.3
Recommended cross-sectional area to DINVDE 0276-1000 and DINVDE 0100-540 (PE) trefoil arrangement, up to 50C ambient
temperature.
IDC
[A-]
1.
(2.)
[mm]
[mm]
Iv
[A~]
20
1x
DCS 50x-0025-xx
25
1x
PE
1.
(2.)
[mm]
[mm]
[mm]
1x 4
[Nm]
1 x M6
DCS 50x-0050-xx
50
1 x 10
41
1x
1x 6
1 x M6
DCS 50x-0075-xx
75
1 x 25
61
1 x 25
1x 16
1 x M6
DCS 50x-0100-xx
100
1 x 25
82
1 x 25
1x 16
1 x M6
DCS 50x-0110-xx
110
1 x 25
90
1 x 25
1x 16
1 x M6
DCS 50x-0140-xx
140
1 x 35
114
1 x 35
1x 16
1 x M6
DCS 50x-0200-xx
200
2 x 35
1 x 95
163
2 x 25
1 x 95
1x 25
1 x M8
13
DCS 50x-0250-xx
250
2 x 35
1 x 95
204
2 x 25
1 x 95
1x 25
1 x M8
13
1 x 95
13
DCS 50x-0270-xx
270
2 x 35
1 x 95
220
2 x 25
DCS 50x-0350-xx
350
2 x 70
286
2 x 50
DCS 50x-0450-xx
450
2x
95
367
2 x 95
1x 25
1 x M8
1x 50
1 x M8
13
1x 50
1 x M10
25
25
DCS 50x-0520-xx
520
2x
95
424
2 x 95
1x 50
1 x M10
DCS 50x-0680-xx
680
2 x 120
555
2 x 120
1x120
1 x M12
50
DCS 50x-0820-xx
820
2 x 150
669
2 x 120
1x120
1 x M12
50
50
DCS 50x-0903-xx
900
4x
3 x 150
734
4 x 70
3 x 95
1x150
2 x M12
DCS 50x-1000-xx
1000
2 x 185
95
816
2 x 150
1x150
1 x M12
50
DCS 50x-1203-xx
1200
4 x 120
979
4 x 95
3 x 120
1x185
2 x M12
50
DCS 50x-1503-xx
1500
4 x 185
1224
4 x 150
2x150
2 x M12
50
2x240
2 x M12
50
3x120
4 x M12
50
3x120
4 x M12
50
50
DCS 50x-2003-xx
2000
8 x 120
6 x 185
1632
4 x 240
DCS 50x-1903-xx
1900
8 x 120
6 x 185
1550
4 x 240
DCS 50x-2053-xx
2050
8 x 120
6 x 185
1673
6 x 120
5 x 150
DCS 50x-2503-xx
2500
7 x 185
2040
8 x 120
6 x 185
4x120
4 x M12
DCS 50x-2603-xx
2600
7 x 185
2122
8 x 120
6 x 185
4x120
4 x M12
50
DCS 50x-3003-xx
3000
8 x 185
2448
7 x 185
4x150
4 x M12
50
50
DCS 50x-3303-xx
3300
8 x 185
2693
7 x 185
4x150
4 x M12
DCS 50x-4003-xx
4000
7 x 300
3264
8 x 240
4x240
4 x M12
50
DCS 50x-4803-xx
4800
8 x 300
3876
6 x 300
3x300
4 x M12
50
DCS 50x-5203-xx
5200
8 x 300
4202
6 x 300
3x300
4 x M12
50
III 2-12
3ADW000165R0201_Technical_Data_e_b
2.4
Power losses
DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600
DCS 500
The units power loss is made up of several different
components:
current-dependent losses PV-I
- of the thyristors
- of the fuses
- of the busbar system
voltage-dependent losses PV-U
- snubber circuit of the thyristors (worst case)
- thyristors at di/dt < 20 A/s
almost constant losses PV-C
- unit electronics
- unit fan
- field supply
y
Converter type
x=1 2-Q
x=2 4-Q
y=4 (400 V)
IDC [A]
2Q
PV-I
DCS50x-0025-y1
DCS50x-0050-y1
DCS50x-0050-61
DCS50x-0075-y1
DCS50x-0100-y1
DCS50x-0110-61
DCS50x-0140-y1
25
50
50
75
100
110
140
25
50
50
75
100
100
125
60
123
DCS50x-0200-y1
DCS50x-0250-y1
DCS50x-0270-61
DCS50x-0350-y1
DCS50x-0450-y1
DCS50x-0520-y1
DCS50x-0680-y1
DCS50x-0820-y1
DCS50x-1000-y1
200
250
270
350
450
520
680
820
1000
180
225
245
315
405
470
610
740
900
DCS50x-0903-y1
DCS50x-1203-y1
DCS50x-1503-y1
DCS50x-2003-y1
900
1200
1500
2000
900
1200
1500
2000
DCS50x-1903-81
DCS50x-2053-y1
DCS501-2503-y1
DCS502-2503-y1
DCS501-3003-y1
DCS502-3003-y1
1900
2050
1900
2050
2500
DCS50x-2053-91
DCS50x-2603-91
DCS50x-3303-y1
DCS50x-4003-y1
DCS50x-4803-y1
DCS50x-5203-y1
y=5 (500 V)
[W]
4Q
[W]
PV-U
30
30
60
123
47
47
175
207
30
50
175
207
47
70
311
50
311
70
488
656
50
50
488
656
70
70
840
1040
1238
1622
1986
2527
50
70
70
105
125
125
840
1040
1238
1622
1986
2527
70
80
80
140
160
160
4510
4740
5950
420 4510
460 4740
470 5950
600
640
660
3000
8250
8400
9570
9900
7160
8250
7820
9750
9900
2050
2600
3300
4000
4800
5200
2050
2600
3300 10850
4000 12300
4800
5200 17250
3000
PV-U
590
900
450
900
570 10850
480 12300
1390 17250
y=7 (690 V)
[W]
PV-I
2500
y=6 (600 V)
PV-I
y=8 (790 V)
[W]
PV-U
y=9 (1000V)
[W]
PV-I
PV-U
PV-I
PV-U
[W]
PV-I
PV-U
2630
2690
4650
4800
108
46
284
100
781
100
1119
110
4190
930 4190
1170
5540
6820
850 5540
1100 6820
1080
1370
1140
1220
1510
1410
1510
7150
1410 7300
1510 8930
1850 8400
1740 9430
1850 10300
1800
1820
1830
2210
2090
2210
1470 11700
1860 13350
2750 16800
7090
9420
1780 11600
2230 15400
3250
880 8050
800 8930
1200 8400
620 9430
1200 10300
780 11700
660 13350
16800
1800
8050
8930
8400
9430
10300
1190 11700
1520 13350
2300 16800
PV I part PV I * 0.4 *
x%
x%
+ PV I * 0.6 *
100%
100%
III 2-13
3ADW000165R0201_Technical_Data_e_b
2.5
DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600
Fan assignment for DCS 500
Model
Configuration
Fan type
Converter type
C1
CN 52 B2
C1
W2E 143
C2
W2E 200
DCS 50x-1000-y1
C2
W2E 250
A5
D2E 160
A6
GR31M
400...500 V
A6
GR31M
500...690 V
DCS 50x-3303-y1...
DCS 50x-5203-y1
A7
GR35C
400 V / 690 V
CN 52 B2
W2E 143
W2E 200
W2E 250
D2E 160
GR31M
GR31M
GR35C
380... 500 V
525... 690 V
400 / 690 V
Rated voltage [V] 208...230; 1~ 230; 1~
230; 1~
230; 1~
230; 1~ 400...450 400...500 500...690
400...500
500...690
500
450...500
600...690
Tolerance [%]
10
+6/-10
+6/-10
+6/-10
10
10
10
+5/-10
10
Frequency [Hz]
50
60
50
60
50
60
50
60
50
60
50
60
50
60
50
60
Power
14
13
26
29
64
80
135 185 653 860
800
2900
1340
3600
1200
800
consumption [W]
700
2200
3300
Current
0.14 0.12 0.12 0.13 0.29 0.35 0.59 0.82 2.50 3.4
1.45
6.5
2.0
4.9
1.2
0.9
consumpt. [A]
0.91
2.3
3.0
Blocking current < 0.25 < 0.2 < 0.3 < 0,4 < 0.7 < 0.8 < 0.9 < 0.9 3.75 4.5 at 450 V at 500 V at 690 V
at 500 V at 400 V at 400 V
[A]
8.5
8.5
8.5
>25
>30
4.4
Air flow [m3/h]
156 180 375 440 925 1030 1860 1975
freely blowing
Air flow [m3/h]
800 750
1500
1600
1500
1600
4200
4250
at working point
2.5 A 3.2 A
1.26 A
1.6 A
0.7 A
1.65 A
3.6 A
4.1 A
(450V )
(500V )
(500V )
(400V )
(400V )
(690V )
Max. ambient
< 60
< 85
< 75
50
< 55
< 55
temperature [ C]
Useful lifetime of
appr.
appr.
appr.
appr.
appr. 30000 h/40
grease
25000 h/60 45000 h/60 45000h/60
40000 h
Protection
Impedance
Temperatur detector: UN 230 V~;
IN 2.5 A~
Increased losses due to increased current with a blocked rotor will not result in a winding temperature, higher than permissible for the insulation class being
involved.
M
~
X2: 1
X2: 1
M
~
M
~
X2: 1
2 3
TW TW
U1
V1
W1
U2 V2 W2 PE TK TK
gray
brown
white
blue
white
black
green/yellow
X2: 1
gray
M
~
at
U1-W2
V1-U2
W1-V2
Fan_con_c.dsf
U2-V2-W2
Converter housing
Config. 1
Config. 2
Connection
Config. 3
Config. 4
III 2-14
3ADW000165R0201_Technical_Data_e_b
Config. 5
DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600
Monitoring the DCS 500 power section
a. The power sections of sizes C1 and C2 are
monitored by an electrically isolated PTC thermistor detector, which is installed on the likewise
electrically isolated heat sink near the thyristors.
The resistance change proportional to the
temperature is acquired and evaluated in the
units software. If the temperature rises above a
certain value predefined by the unit coding
involved, then first an alarm will be outputted,
and - if the temperature continues to rise - an
error message. This means that changes in the
rated cooling conditions, such as cooling air
volume and temperature, the fan itself, overload
due to an excessively high load current, etc. are
detected.
b. The size-A5 power section is likewise monitored
by an electrically isolated PTC thermistor detector, which is installed on the non-isolated heat
sink in an isolated configuration. Evaluation of
the resistance and the protection effect correspond to those mentioned for point (a.) above.
c. The size A6 and A7 power section is not directly
monitored by an electrically isolated PTC thermistor detector. For this size, the same thermistor detector is used as for (a.) and (b.) above, but
III 2-15
3ADW000165R0201_Technical_Data_e_b
III 2-16
3ADW000165R0201_Technical_Data_e_b
Control boards
Jumper coding
5V
single ended: 3
*
24
12/24 V
12/24 V
5V
24
23
22
3
2
1
differential:
24
23
22
3
2
1
23
22
2
1
24
23
22
3
2
1
Terminal
AI2-
S2
n. c. to +10V
X3:7
22-23
2
1
22 k ->+10V
X21
2
1
2
1
6
5
DDCC+
Fig. 3.1/1
X16
X34
B1
A1
6
5
10 1
X3
B1
A1
X2
X1
grey TxD
R2716
S4 * 21
* default value
ASIC
X13
2
1
21
D35
V260
S1*23
10 1
24
23
22
X4
10 1
X5
ASIC function
ASIC = Application Specific Integrated Circuit
Most of the measurements and control functions for
the DCS500 are done in the ASIC:
- communication with control panel (RS 485)
- communication with field exciters (RS 485)
- measurement
- watchdog function
- A/D and D/A-conversion control
- thyristor firing pulse generation
Watchdog function
The control board has an internal watchdog. The
watchdog controls the running of the control board
program. If the watchdog trips, it has the following
effects:
- Writing to FPROM is disabled.
- Thyristor firing control is reset and disabled.
Normal situation
Alarm
Fault
Fig. 3.1/2
III 3-1
3ADW000165R0201_Technical_Data_e_b
blue RxD
10 1
X6
247
Con2_1_c.dsf
D33
X12
X11
21
X17
6
5
A1
B1
Back up
capacitor
A1
B1
2
1
H1
X18
23-24
S4
X14
CPU
24
23
22
3
2
1
6
5
X33
2
1
13 mA
S2*
A1
B1
247
S1
X37
X7
SDCSPOW-1
X37:
+48V1
+48V2
X37
X37
26 wire
Flat
cable
A13
+24V
A11,
B11
+15V
A10,
B10
-15V
A8,
B8
0V
GND
SDCS-CON-2
X16:4
Reg.
X34:1
X33:1
Reg.
Watchdog
Reg.
Ref.
regul.
Supply for signal
measurments
0V
A9,
AGND B9
Reg.
+5V
B2,B3,
B4,B5
A2,A3,
A4,A5
B1
Fig. 3.1/3
A12,
B12
+5 V
+15 V
-15 V
B4 / B5
B10
B8
+24 V
+48 V1
+48 V2
+19 V
+38 V
+38 V
B11
B12
--------
TxD/
RxD
RS485
+24 V/ 150 mA
GND
SDCS-CON-2
1
GND
5
X16
Fig. 3.1/4
X16
grey
grey
TxD
blue
blue
RxD
blue blue
grey grey
max. 10 m
Partner
Fig. 3.1/5
III 3-2
3ADW000165R0201_Technical_Data_e_b
SDCS-CON-2
2
3
4
5
6
7
8
9
10
X4:1
2
Software
90-270 V
X2:
X3:1
30-90 V
R2716
8-30 V
+
-
S4
2 100k
1n
5 3
4 100k 1n
6
GND
1
22 K
S1:23-24
AITAC
12 + sign
90...270 V
30...90 V R 2716/
8...30 V Software
20 V
AI1
20 V
AI2
40 V
AI3
40 V
AI4
40 V
0V
+10V
-10V
100 47.5
AO1
AO2
100n
8
9
10
0V
4 5 6
S1:
+24V 1 2 3
10 11 12
+24V 7 8 9
ChB +
16 17 18
+24V 1314 15
ChZ +
ChZ GND
Sense GND
Sense Power +
10
Power-Source
5V/
12V/24V
4.75k 47.5k
10k
DI1
220n
DI2
DI3
4
5
DI4
DI5
DI6
7
8
DI7
DI8
+48 V/ 50 mA
0V
X1:
10
100
+24V
DO1
Input value
0...8 V
16...60 V
Output value
0.25 mA *
0.2 mA *
Sense lines for GND and supply to correct voltage drops on cable (only if 5V/12V encoder is in
use)
Selectable on POW-1 board
Signal definition
by
Software
Signal definition
by
Remarks
^ "0" status
=
^ "1" status
=
Remarks
100n
DO2
DO3
DO4
DO5
DO6
50 * mA
Software
DO7
0V
Con2_3_d.dsf
The terminal connectors X3: ... X7: and X16: are removable. When
connecting the terminal blocks to the CON-2 board, please start with
the left connector at first and make sure, that they will be placed on
the board in the correct sequence and without spaces in between.
Fig. 3.1/6
5 * mA
5 * mA
5 * mA
ChB -
X7: 1
2
Remarks
ChA +
ChA -
+/- I-act
S1:
X6:1
5 * mA
5 * mA
0V (AOx)
Remarks
Power Common
mode
range
+10V
X5:1
2
Input/output Scaling
values
by
Hardware
100k
100k
+
-
Resolution
[bit]
III 3-3
3ADW000165R0201_Technical_Data_e_b
III 3-4
3ADW000165R0201_Technical_Data_e_b
If an SDCS-CON-2 (without I/O board SDCSIOB-3) together with a pulse encoder is used for
speed measurement, the incremental encoder
supply voltage must be selected by jumpers X5,
X4 and X3.
The SDCS-POW-1 works on a switched mode basis in fly back configuration. It generates all necessary DC voltages for the SDCS-CON-2 and all
other electronic boards. The input voltage can be
Relay output
AC supply
yes
12 V B B B
15V
24V
yes
15 V A A A
B
15V
24V
no
A A
24 V A
B B B
15V
24V
no
SW1
*
+
X95
line potential !
M1
AC supply selection
230 V
115 V
230 V
110 V
230 V *
X99
Backup supply
for SDCS-POW-1
220
A A
5 V* A
B B B
SW1
DO8
Sensefunction
SDCS-POW-1
X5 X4 X3
230 V
X3
X4
X5
115 V
X96
Jumper coding
T 10
115 V
26
default value
13
135
Pow1_f.dsf
Fig. 4.1/1
14
X37
A
B
A
B
A
B
X5 X4 X3
15V
24V
AC Supply voltage
Supply voltage
115 V AC
Tolerance
-15%/+10%
Frequency
45 Hz ... 65 Hz
Power consumption
120 VA
Power loss
60 W
Inrush current
20 A / 20 ms
Mains buffering
min 30 ms
Supply voltage +5 V *
Test terminals X 5 B
+15 V
X3 A
Backup supply
These two terminals are used to add additional capacitance (e.g. KJ 2001) to the existing ones to increase the mains buffering time. More detailed data
is available on request via your ABB representative.
230 V AC
-15%/+10%
45 Hz ... 65 Hz
120 VA
60 W
10 A / 20 ms
min 30 ms
+24 V
+48 V2
X3 B heat sink T 10
Output X96-DO8
Potential isolated by relay (NO contact)
MOV- element (275 V)
Contact rating: AC: 250 V~/ 3 A~
DC: 24 V-/ 3 Aor 115/230 V-/ 0.3 A-)
III 4-1
3ADW000165R0201_Technical_Data_e_b
III 4-2
3ADW000165R0201_Technical_Data_e_b
Note:
If this PCB is used as a spare part for a DCF.... ,
then the resistors R113/R116/R119 (value = 0 )
must be removed.
265
16
X13
T14
SDCS-PIN-1X
T21,T13
T26,T16
T23 T15
T11 T24
XT21
XT13
XT26
XT16
XT23
XT15
XT22
XT12
XT25
282
XT14
XT24
XT11
R116
R113
R119
R112
R115
X22
PTC
X12
T101
T102
line potential !
T103
W18,W17,W15
U1
C1
V1
D1
W1
R1
18
W10
16
X121(GND)
X122(IACT)
Fig. 5.1/1
Board type
Current transformer ratio
Max. rated voltage [V]
Rated current [A]
W10
2Q=
; 4Q=
W15
zero current detection
W17
rated current scaling
W18
rated current scaling
W80
HW type coding
W81
HW type coding
W82
HW type coding
Table 5.1/1
500
25
PIN 11
1500:1
500
50
500
75
PIN 12
1500:1
600
50
III 5-1
3ADW000165R0201_Technical_Data_e_b
5.2
The power interface board is used for DCS converter modules construction type C1 and C2. There
are different versions in use. The used types are:
Spare part
The protection of the power part is done by using
RC circuits. Snubber circuits are wired in parallel to
each thyristor with fuses in between. RCD elements are protected by the fuses F 101 to F 103.
The AC voltage measurement is taken from behind
the fuse.
Added on PIN-20xB
253
C109
C108
P125
C1
C1
T24
1
2
3
X95
F101
P125
P124
X92
R179
R178
R177
W82
W81
W80
X6
X3
P130
T21
X4
R151
R149
R150
X22
W10
T25
T23
X121 (IACT)
X120 (GND)
PTC
U1 V1 W1
Fig. 5.2/1
35
R176
R175
R174
R173
R172
R171
R170
R169
R168
R167
R166
R165
R164
R163
R162
R161
R160
X12
1
2
3
T16
P127
R248
R249
R250
R251
R252
T14
P131
F102
P126
T13
8
9
W1
V1
P122
T15
X13
D1
P123
T11
1
16
P129
X93
U1
X5
16
P128
T12
T26
35
F103
X91
T22
MOV
line
potential!
X94
P124
280
SDCS-PIN-20X
Removed on
PIN-20xB
C108
X94
III 5-2
3ADW000165R0201_Technical_Data_e_b
2-Q Converters
Table 5.2/1
1000:1
125
180
225
315
3000:1
610
Board type
Current transformer ratio
Rated voltage [V]
Rated current [A]
2-Q/4-Q selection
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
33
zero current detection
47.5 zero current detection
100 zero current detection
1k
rated current scaling
1k
rated current scaling
332 rated current scaling
332 rated current scaling
332 rated current scaling
332 rated current scaling
332 rated current scaling
47.5 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
10
rated current scaling
10
rated current scaling
10
rated current scaling
Table 5.2/2
900
Settings of the SDCS-PIN-20xB board for 2-Q converters if a DCS converter is equipped with it by ABB
4-Q Converters
W10
W80
W81
W82
R248
R249
R250
R251
R252
R149
R150
R151
R160
R161
R162
R163
R164
R165
R166
R167
R168
R169
R170
R171
R172
R173
R174
R175
R176
R177
R178
R179
740
PIN 206B
1000:1
600:1
600
100
245
405
condition
100
PIN 205B
600:1
500
405
470
1000:1
100
140
200
250
350
PIN 205B
600:1
500
450
520
3000:1
680
820
1000
PIN 206B
1000:1
600:1
600
110
270
450
Settings of the SDCS-PIN-20xB board for 4-Q converters if a DCS converter is equipped with it by ABB
III 5-3
3ADW000165R0201_Technical_Data_e_b
W10
W80
W81
W82
R248
R249
R250
R251
R252
R149
R150
R151
R160
R161
R162
R163
R164
R165
R166
R167
R168
R169
R170
R171
R172
R173
R174
R175
R176
R177
R178
R179
Board type
Current transformer ratio
Rated voltage [V]
Rated current [A]
2-Q/4-Q selection
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
HW type coding
33
zero current detection
47.5 zero current detection
100 zero current detection
1k
rated current scaling
1k
rated current scaling
332 rated current scaling
332 rated current scaling
332 rated current scaling
332 rated current scaling
332 rated current scaling
47.5 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
33.2 rated current scaling
10
rated current scaling
10
rated current scaling
10
rated current scaling
Fig. 5.2/2
Typical armature circuit thyristor converter diagram with SDCS-PIN-20x (PIN-20xA), PIN-20xB board
for a 2Q/4Q C1/C2 type converter
III 5-4
3ADW000165R0201_Technical_Data_e_b
X12:
11,12
HWCDD5
16
UV
VW
UA +
NC
NC
13
15
ACOD1
ACOD2
12,14
GNDI
4,2
SR2
0V
1k5
FORWARD
+ 48 V1
11
BZP6
10
BZP5
8,6
BZP4
SR1
BZP3
+48 V1
BZP2
820R
W80
1k5
W81
HW-coding
3k3
W82
W10
REVERSE
0V
BZP1
X13:
14
UU
15
HWCOD3
UA -
ANTC
8,13
9,10
HWCIN4
GNDI
STWA
IDC
Control board
IDCM
5M / 6M
see table
for R1xx
X6:
X5:
19
17
31
29
35
33
11
27
25
19
17
31
29
35
33
11
27
25
1.6
2.5
1.4
2.3
1.2
2.1
2.6
1.5
2.4
1.3
2.2
1.1
* Values
changed
at PIN-20xB
Removed
on PIN-20xB
6 x 15
6A
F103
F102
F101
W1
V1
U1
D1
C1
X22:
X4:
X3:
C1 (+)
1.5
2.2
1.3
2.6
1.1
2.4
R57
V15
V22
V13
V26
V11
V24
N/1
P1
S2
S1
N/1
P1
p20x_d.dsf
S2
S1
T53 P2
U1 V1 W1
T51 P2
PE
1.2
2.5
1.6
2.3
1.4
2.1
V12
V25
V16
V23
V14
V21
D1 (-)
5.3
Construction type
Conv. nom. voltage [V] *
Rated mains voltage [V AC]
Value f. conv. nom. volt at
SET(TINGS) block *
Measuring board SDCS-
Y=4 (400V)
Y=5 (500V)
Y=6 (600V)
Y=7 (690V)
220500
270600
300690
350790
4501000
5301190
500
600
690
800
1000
1200
PIN-51
PIN-51
PIN-51
PIN-51
PIN-51
PIN-51
Resistors W1W26
all resistors are 0
Galvanic isolation
Resistors Rx on PIN51
DC-DC transducer A92
Switch position RG *
Transformer T90
Secondary Terminals *
27.4 k
27.4 k
27.4 k
27.4 k
27.4 k
27.4 k
6 (810 V)
5 (945 V)
4 (1080 V)
2 (1350 V)
1 (1620 V)
2U2
2V2
2W2
2N
2U3
2V3
2W3
2N
2U4
2V4
2W4
2N
2U5
2V5
2W5
2N
2U6
2V6
2W6
2N
8680A1
7 (675 V)
3ADT 745047
2U1
2V1
2W1
2N
* 12-pulse serial and sequential have a different selection between S CONV NOM VOLT (42.08) and the
scaling of measurement channel. See 12-pulse manual for DCS 600.
III 5-5
3ADW000165R0201_Technical_Data_e_b
Fig. 5.3/1
B1
15
UA -
ANTC
III 5-6
3ADW000165R0201_Technical_Data_e_b
1k5
0V
1.6
B2
13
15
ACOD1
ACOD2
B5
HWCDD5
HWCIN4
B8
X12:
B6
X12:
HWCOD3 5
B1
A4
10
NC
W10
820R
W80
1k5
1k5
820R
W81
W70
3k3
1k5
W82
W71
HW-coding jumpers
+ 48 V1
8k2
3k3
W83
W72
1.4
A6,B6
A6,B6
A2
A1,B1
A3,B3
A2
A1,B1
A3,B3
A4,B4
A8,B8
A8,B8
A4,B4
A7,B7
A9,B9
A2
p41_51_A7.dsf
SDCS-PIN-41
A1,B1
A3,B3
A4,B4
A9,B9
A7,B7
A8,B8
A6,B6
A10,B10
CF
A5,B5
CE GF
X113:
A5,B5
2.1
A2
A4,B4
A9,B9
A7,B7
A8,B8
A6,B6
X213:
A10,B10
A7,B7
A9,B9
A5,B5
X213:
A10,B10
CD GE
A1,B1
A1,B1
FWD
A2
A3,B3
A3,B3
A1,B1
A5,A6
A7,A8
A2
A3,B3
A4,B4
A4,B4
REV
A6,B6
A6,B6
A2,A3
B3
4
A8,B8
B4
B5
A10,B10
A8,B8
X213:
A5,B5
CF
Fast-on
S1
1.5
A7,B7
CC GD
CE GF
A9,B9
2.3
2.2
SDCS-PIN-41
CD GE
A9,B9
CB GC
1.3
A7,B7
1.2
CC GD
D1
C1
W1
V1
CA GB
2.6
X22:
U1
B6
2.5
CB GC
1M
A5,B5
GA
1.1
W26
W21
W20
W25
W16
W15
W11
0V
CA GB
W24
W19
W14
W9 1M
W5
B7
X113:
A10,B10
W23
W22
2.4
W18
W17
GA
W13
W12
W8 1M
W4
A5,B5
X113:
A10,B10
501
Rx
W7 1M
W6 1M
W3
X25:
X24:
X23:
SDCS-PIN-51
+48 V1
8,6
GNDI
4,2
11
12,14
BZP6
SR1
BZP5
R15 18R
X13:
B8
0V
500
401
Rx
W2
R8 18R
W1
SR2
BZP3
BZP4
BZP2
R21 560R
X13:
1
R20 270R
400
301
Rx
Rx201
R10 18R
BZP1
R19 120R
A8
R18 68R
Control board
A6
UA +
18R
A1
300
R13 18R
16
R17 33R
R14 18R
200
R12 18R
101
R11 18R
5M
R9 18R
Rx
R7 18R
100
R6 18R
R26 100R
A2
0V
R5 18R
R25 47R
B7
R4 18R
R24 47R
A7
R3 18R
R23 47R
VW
UU
A5,B2
R2 18R
14
A4,B4
R22 47R
UV
8,13
STWA
9,10
IDC
X12:
A3,B3
R16
GNDI
X12:
11,12
IDCM
Rx
removed wires
R1 18R
Typical armature circuit thyristor converter diagram with SDCS-PIN-41 and SDCS-PIN-51 boards for a
4-Q A7 type converter with galvanic isolation
R22
R15
R26
R13
R24
R11
4000/1
1.4
V15
V22
V13
V26
V11
C22
C15
C25
C12
F12
C23
C26
F15
C16
F16
C21
C14
C13
F13
C24
C11
2.5
1.2
2.3
1.6
2.1
V16
V12
R25
R12 V25
R23
R16 V23
R21
R14 V21
V14
D1 (-)
F14
4000/1
S2 P1
S1
T52 P2
F11
S2 P1
S1
T51 P2
PE U1 V1 W1
V24
F90
C1 (+)
1.5
2.2
1.3
2.6
1.1
2.4
R57
2N
T90
F11
20
10
17
9 1
X99:2
X99:1
SDCS-POW-1
A92
aux. supply
230 V AC
17
10nF
Input
voltage
OPAMP
6 M
20
appr. 3.9 k
10
TRANSDUCER
1:1
GAIN
7 STEPS
+15V
0V
-15V
Fig. 5.3/2
RG
Output
voltage
POWER SUPPLY
1
230 V AC
appr. 280nF
0V
Data
Selectable voltage gains:
Switch position
Output voltage:
Auxiliary power:
Clearance in air:
9,84 V / 5 mA
230 V 15 %; 50/60 Hz; 3 W
Auxiliary power to Output: >13 mm
Input/Output to Auxiliary power: >14 mm
2000 V
5000 V
- 10 + 70 C
appr. 0.4 kg
Insulation voltage:
Insulation test voltage:
Ambient temperature range:
Weight:
The voltage gain and frequency response is especially designed for DCS 500B
and DCS 600 converters.
Side view
Buttom view
2.0
76.0
10.0
20
17
80.0
100.0
70.0
7.0
112.0
Gain selector
RG
5.0
Fig. 5.3/3
50.0
60.0
Dimensions in mm
Fig. 5.3/4
III 5-7
3ADW000165R0201_Technical_Data_e_b
9 10
Location of terminals
2N
2U6
2U5
2U4
2U3
2U2
2U1
1V
2V6
2V5
2V4
2V3
2V2
2V1
1W
1N
S
Fig. 5.3/5
Data
Selectable transfer ratios Uprim:
Output voltage:
Insulation voltage:
Isolation test voltage:
Ambient temperature range:
Weight:
max 110
max 116
80
130
5.2 x 7.7
118....120
130
Fig. 5.3/6
Dimensions in mm
III 5-8
3ADW000165R0201_Technical_Data_e_b
Remark
The terminals on the primary side of the
transformer are in special design (lug terminals).
Handling hints: First turn the screw counter-clockwise to the end stop, then swing
out the shrowding cover.
Put in the cable lug, swing
in the shrowding cover and
fasten the connection by
turning the screw clockwise.
V14
V11
V16
V13
V12
X313 S
C
C
SDCS-PIN-41/PIN-48
X313
X413
X213
X113
X513
X13
C
B
X113
S2
S1
X413 S
X13 S
X12
X12 S
V1
W1
SDCS-PIN-5x
C1
V15
X213
X25
C
D1
X13
Fig. 5.4/1
X24
U1
X12
SDCS-CON-x
2q_c34_a.dsf
X313 S
C
T6
D
T2
F
X213
X113
C
T3
SDCS-PIN-41/PIN-48
X313
X413
X213
X113
X513
X13
C
T1
B
X113
S2
S1
X413 S
X13 S
X12
X12 S
V1
W1
SDCS-PIN-5x
C1
C
T4
X213
X25
C
D1
X13
Fig. 5.4/2
X24
U1
X12
SDCS-CON-x
SDCS-PIN-41/PIN-48
V25
V12
V23
V16
V21
V14
G
G
G
G
G
G
V24
V11
V26
V13
V22
V15
C
C
C
C
C
C
G
G
G
G
G
G
4q_c3a_a.dsf
SDCS-PIN-41/PIN-48
X25
T1
C
T3
T6
B
C
T2
D
C
T5
E
X113
X213
SDCS-PIN-41/PIN-48
X313
X413
X213
X113
X513
X13
X113
S2
S1
X313 S
X413 S
X13 S
X12
SDCS-PIN-5x
C1
W1
X12 S
V1
D1
X13
Fig. 5.4/3
X24
U1
V14
V21
V11
V26
V16
G
G
G
G
G
V23
V13
V22
V12
V25
V15
C
C
C
C
C
G
G
G
G
G
G
X213
X12
SDCS-CON-x
V24
4q_c4a_a.dsf
III 5-9
3ADW000165R0201_Technical_Data_e_b
G4
C4
G1
C1
G6
C6
G3
C3
G2
C2
G5
C5
T4
T1
T6
X113
T2
X2
T5
X213
SDCS-PIN-41
line potential !
U1
W5
W4
W3
W2
1 X23 2
X22 X122
4
Two
PTC
3
1
2 One PTC
W1
W9
W8
W7
W6
W1
W16
W15
W14
W13
W21
D1
Isolating
supports
W20
W26
W19
W25
W18
W24
W12
W10 W70
W71
W72
W80
W81
W82
R1
1 X25 2
.......
R21
R22
X12S
X413S
W83
X13S
X313S
R26
W17
W23
X13
100
C1
W11
X12
S3
V1
X24 2
W22
X313
R123
X413
W5
Conductive
supports
see diagram
power part
PTC
X213
Fig. 5.4/4
T3
X113
X1
100
line potential !
X513
S2
S1
SDCS-PIN-51
305
Fig. 5.4/5
U1
S3
V1
X12
W1
C1
D1
SDCS-PIN-52
Figure 5.4/6
III 5-10
3ADW000165R0201_Technical_Data_e_b
Current coding
2000
1900
A6
2500:1
2050 2500
3000
2050
2600
3300
A7
4000:1
4000 4800
5200
900
A5
2500:1
1200 1500
Zero current
detection
Construction type
Current transf. ratio
Rated current [A]
18
R1-R4
18
R5
18
R6
18
R7
18
R8
18
R9
18
R10
18
R11
18
R12
18
R13
18
R14
18
R15
18
R16
33
R17
68
R18
120
R19
270
R20
560
R21
47
R22
47
R23
47
R24
47
R25
100
R26
code_tab_PIN1_PIN20_PIN51_d.dsf
Voltage coding
Construction type
Conv. nom. voltage [V]
A5
A6 / A7
A7
Y=4 (400V) Y=6 (600V) Y=4 (400V) Y=6 (600V) Y=7 (690V) Y=8 (790V)
Y=5 (500V) Y=7 (690V) Y=5 (500V)
Y=9
(1000V)
500
600
690
800
1000
PIN-51
PIN-51
PIN-51
PIN-51
PIN-51
A7
Y=1
(>1000V)
see
chapter
Galvanic
isolation
the converters can be used at lower line voltage then specified by the y-value without hardware modifications, if
the nominal line voltage applied to the converter is not lower than 45% for y=5...9 and not lower than 55% for y=4.
HW type coding
Construction type
1200
1500
Current [A]
500
500
Voltage max. [V]
W70
W71
W72
W80
W81
W82
W83
* see Software description
Temp. sensor coding
R 57 as a temp. sensor for A5, A6, A7
S3
3
4
2
A6 / A7
A5
2000
500
900
600/690
1500
600/690
2000
600/690
>2000 *
all *
2 Q - 4 Q coding
2-Q
4-Q
W10
III 5-11
3ADW000165R0201_Technical_Data_e_b
Fig. 5.4/7
15
UA -
ANTC
III 5-12
3ADW000165R0201_Technical_Data_e_b
B5
HWCDD5
HWCIN4
B8
X12:
B6
B1
B2
1k5
NC
W10
820R
W80
1k5
1k5
820R
W81
W70
3k3
1k5
W82
W71
8k2
3k3
W83
W72
0V
R15 18R
X12:
HWCOD3 5
15
ACOD2
A4
8,6
SR1
13
A5,A6
4,2
SR2
ACOD1
A7,A8
12,14
GNDI
3
4
HW-coding jumpers
+ 48 V1
A2,A3
11
BZP6
10
FWD
B3
BZP5
B6
A6,B6
A4,B4
A6,B6
A4,B4
A2
A1,B1
A2
A1,B1
A3,B3
A8,B8
A8,B8
A3,B3
A7,B7
A9,B9
A5,B5
X213:
A10,B10
A7,B7
A9,B9
A5,B5
X213:
A10,B10
CE GF
1.4
A2
A1,B1
A3,B3
A4,B4
A9,B9
A7,B7
A8,B8
A6,B6
A10,B10
X113:
A5,B5
CF
A3,B3
A4,B4
A9,B9
A7,B7
A8,B8
p41_51_A7.dsf
SDCS-PIN-41
2.1
A2
CD GE
A1,B1
A1,B1
1.6
A3,B3
A3,B3
CC GD
A2
A4,B4
A4,B4
2.3
A1,B1
A6,B6
A6,B6
A2
A8,B8
A6,B6
A10,B10
X213:
A5,B5
CF
A8,B8
CB GC
CE GF
SDCS-PIN-41
CD GE
Fast-on
S1
1.5
D1
C1
W1
V1
A7,B7
1.2
CC GD
2.2
X22:
U1
A9,B9
CA GB
1.3
1M
A7,B7
2.5
CB GC
2.6
W26
W21
W20
W25
W16
W15
W11
A9,B9
GA
CA GB
1.1
W24
W19
W14
W9 1M
W5
A5,B5
X113:
A10,B10
W23
W22
GA
W18
W17
2.4
W13
W12
W8 1M
W4
X25:
X24:
X23:
SDCS-PIN-51
A5,B5
X113:
A10,B10
501
401
W7 1M
R8 18R
W6 1M
+48 V1
REV
B4
0V
B5
BZP4
BZP3
B7
X13:
1
R12 18R
BZP2
0V
500
400
301
201
101
R10 18R
BZP1
X13:
B8
R21 560R
B1
R20 270R
A8
R19 120R
A6
R18 68R
Control board
UA +
R17 33R
A1
300
200
5M
R13 18R
16
R16 18R
R14 18R
100
R11 18R
A2
0V
R9 18R
A7
R7 18R
W3
R6 18R
R26 100R
W2
R5 18R
R25 47R
W1
R4 18R
R24 47R
VW
UU
A5,B2
R3 18R
R23 47R
B7
R2 18R
14
A4,B4
X12:
A3,B3
R22 47R
UV
8,13
IDC
GNDI
9,10
IDCM
STWA
X12:
11,12
R1 18R
R22
R15
R26
R13
R24
R11
F11
F14
V15
V22
V13
V26
V11
C22
C15
C25
C12
F12
C23
C26
F15
C16
F16
C21
C14
C13
F13
C24
C11
2.5
1.2
2.3
1.6
2.1
V16
V12
R25
R12 V25
R23
R16 V23
R21
R14 V21
V14
D1 (-)
G
K
1.4
V24
4000/1
S2 P1
S1
T52 P2
C1 (+)
1.5
2.2
1.3
2.6
1.1
2.4
R57
4000/1
S2 P1
S1
T51 P2
PE U1 V1 W1
The CZD-01A board has in addition a cathode / anode voltage measurement of all thyristors. The voltage measurement provides a sharp detection of
DC load condition.
Basically two conditions need to be fulfilled to get a
signal current equal to zero:
the current detection has to indicate current
equal to zero AND
the voltage detection has to indicate current
equal to zero
The activation of the board must be set in the software via parameter:
DCF500B
DCF600
106
MP1 1 2 3
*
47
X17:
X12:
X13:
SDCS-CZD-01A
J1
* default position
X13:
X12:
X17:
SDCS-CZD-01A
X27:
X12:
X22:
X13:
X23:
X17:
SDCS-CON-2
CZD01A.dsf
U1
V1 W1
CON-2
MP1
470k
to zero
current interface
current detection
CON-2
&
1
2
3
J1
&
D1 (-)
C1 (+)
voltage
detection
&
* default
position
czd01_princ_b.dsf
III 5-13
3ADW000165R0201_Technical_Data_e_b
X12
X17
X22
0V
X13
X23
The board is plugged to the control board connectors X12, X13 and X17. The ribbon cables normally
connected to the control board are connected to
the measurement board connectors having the
same name as the respective connector on the
control board.
Measurement points for following signals are provided:
- the three phase to ground voltages UU, UV, UW
- the three phase to phase voltages UVU, UWV, UUW
X27
SDCS-MP-1
Measurement
points
MP-1layout_b
X13:
X12:
X12:
SDCS-MP-1
SDCS-CON-2
III 5-14
3ADW000165R0201_Technical_Data_e_b
X17:
X27:
X13:
X22:
Measurement
points
X23:
X17:
SDCS-CON-2
X17:
X2:
X3:
X4:
of the I/O's see chapter SDCS-CON-2). These possibilities doesn't increase the number of inputs or
outputs. In addition to this an extension of I/Os by
SDCS-IOE-1 is possible, which increases the
number of inputs.
SDCS-CON-2
X17:
X1:
X5:
X2:
X6:
X7:
X3:
X4:
Analogue I/Os:
standard
Digital I/Os:
all isolated by means of optocoupler/relay, the signal
status is indicated by LED
X1:
X5:
X3: X1:
SDCS-IOB-2
Analogue I/Os:
more input capacity
Digital I/Os:
not isolated
encoder input:
isolated
current source for:
PT100/PTC element
SDCS-CON-2
X17:
X2:
X1:
X6:
SDCS-CON-2
X17:
X2:
X1:
Analogue I/Os:
more input capacity
Digital I/Os:
all isolated by means of optocoupler/relay, the signal
status is indicated by LED
current source for:
PT100/PTC element
X7:
X1: X2:
SDCS-IOB-3
X1: X2:
SDCS-IOB-3
X3: X1:
SDCS-IOB-2
III 6-1
3ADW000165R0201_Technical_Data_e_b
SDCS-CON-2
SDCS-CON-2
X17:
X17:
X2:
X3:
X1: X2:
SDCS-IOB-21
SDCS-IOB-22
SDCS-IOB-23
X2:
X1:
24...48V DC
115 V AC
230 V AC
X1:
X5:
X3: X1:
X3: X1:
SDCS-IOB-2
SDCS-IOB-3
X4:
SDCS-IOB-2
DI2
DI3
DI4
DI5
DI6
S7
4
W16
2
1
W14
DI7
DI8
R4
R5
R6 R7
R8
W15
R3
W13
R2
X5
X4
Line potential !
4*
X6
70
70
R1
1
W11
K8
W9
K5
W7
K4
W5
K3
W3
K2
W1
K1
97.5
S8
DI1
3 4
DO7
DO6
W12
DO5
DO3
W10
DO2
W8
DO1
DO8
W6
SDCS-IOB-2x
X1
DO4
W4
X3
W2
W100 **
233.5
X7
5
4
Jumper coding
time constant
input 2ms
10ms
S7
DI 7
S8
DI 8
*
Fig. 6.1/2
default value
Layout and jumper settings of the SDCS-IOB-2x board
III 6-2
3ADW000165R0201_Technical_Data_e_b
Note:
When the SDCS-CON-2 control board with the SDCS-IOB-2 I/O board is installed,
terminals X6: and X7: on the SDCS-CON-2 must not be used.
Output value
SDCS-IOB-2x
Software
DOx
X4:1
3
K1...K5, K8
Software
potential-isolated by relays
(NO contact element)
Contact ratings:
AC: 250 V~/ 3 A~
DC: 24 V-/ 3 Aor 115/230 V-/ 0.3 A-)
MOV-protected (275 V)
K6,7
Software
potential-isolated by optocoupler
Switching capacity: 50 mA
external voltage: 24 V-
DO2
K2
4
5
DO3
K3
6
7
DO4
K4
8
X5:1
DO5
K5
DO6
3
4
66V
5
6
DO7
66V
DO8
K8
681
X6:1
+
R1
W1
2
3
DI1
Input value
W2
DI2
W4
DI3
W6
DI4
W8
R5
W9
681
R4
W7
DIx
R3
W5
100n
R2
W3
DI5
W10
R6
DI6
Channel 1...8
IOB-21:
0...8 V
18...60 V
IOB-22:
0...20 V
60...130 V
IOB-23:
0...40 V
90...250 V
Signal definition
by
Software
W11 W12
R7
W13
DI7
DI8
W16
X7:1
W100
2
3
up to revision D
Remarks
potential-isolated by optocoupler
(24...48V-)
R1...R8 = 4.7 k
^ "0 signal"
=
^ "1 signal"
=
(115V~)
R1...R8 = 22 k
^ "0 signal"
=
^ "1 signal"
=
(230 V~)
R1...R8 = 47 k
^ "0 signal"
=
^ "1 sig."
=
including tolerance; absolute max
values
W14
R8
W15
Remarks
DO1
K1
Signal definition
by
from
revision E on
+48V
conductive support
iob2x2_b.dsf
If the inputs are supplied from the internal +48 V (X7:3 and/or X7:4) a connection
must be done from either X7:1 and/or X7:2 to ground of the DCS 500 module. In
default condition ground is identical to the converter's frame.
If the inputs are supplied by any external source (+48 V DC, 115 V AC or 230 V
AC) the neutral line / - line must be connected to either X7:1 or X7:2. If the inputs
should be controlled with the same voltage level, but from two different voltage
sources, having probably two different ground levels, the first neutral line should
be connected to X7:1 and the second to X7:2. In this case the jumpers Wx connecting the inputs to X7:2, but controlled by the source, connected to X7:1, must
be cut off.
The same method is needed for the other jumpers Wx.
High frequency grounding is done by 100 nF capacitor.
Fig. 6.1/3
III 6-3
3ADW000165R0201_Technical_Data_e_b
SDCS-CON-2
SDCS-CON-2
X17:
X17:
X2:
X2:
X1:
X1:
X6:
X1: X2:
X1: X2:
X3: X1:
SDCS-IOB-2
SDCS-IOB-3
X7:
SDCS-IOB-3
233.5
conductive supports
V17
SDCS-IOB-3
X2
2
14
13
S1*
8
2
S2*
70
T1
S10 *
S5 *
R110
3
2
1
2
4
1
3
S3*
12
12
X3
S4
24
23
22
X1
11
12
85
70
10
X4
X5
iob3_c.dsf
Jumper coding
S4 Pulse encoder supply
S1
S2
S3
activation of
gain = 1
Ch 500 between
input terminal -10V..+10V
YES
AITAC S1:1-2
AI1 S1:3-4
-1V..+1V
Sum I AC
not equal
to 0
5V
1
3
5
7
9
11
YES
AI2 S1:5-6
S2
8
6
4
2
7
5
3
1
S3 8
7
5
3
1
AI3 S1:7-8
6
4
2
AI4 S1:9-10
S10
gain = 10
8
6
4
2
7
5
3
1
S3 8
7
5
3
1
S2
6
4
2
YES
S5
5V
differential:
5V
3
2
1
*24
PTC
1.5 mA
1
3
PT100
5 mA *
2
4
1
3
12/24 V
23
22
24
23
22
3
2
1
24
23
22
12/24 V
24
23
22
1
3
5
7
9
11
2
4
6
8
10
12
S1:11-12
S1:13-14
3
2
1
2
4
6
8
10
12
1
3
5
7
9
11
24 V *
12 V
2
4
6
8
10
12
13 mA
3
2
1
* default value
Layout and jumper settings of the SDCS-IOB-3 board
Fig. 6.2/2
III 6-4
3ADW000165R0201_Technical_Data_e_b
24
23
22
2
4
X1:1
81-270V
25-90V
TG
Note:
When the SDCS-CON-2 control board with the SDCS-IOB-3 I/O board is
installed, the connection via plugs S4:1-2 and 3-4 on the SDCS-CON-2
must be treated according to the diagram below:
X2:3
8-33V
4
X2:3
5
X2:4
R9
S4 21
X2:
SDCS-IOB-3
X3:1
2
3
4
1 2
+
+
5
6
2
1
6
5
SDCS-CON-x Software
S1
+
-
Terminals X3:, X4: and X5: on the SDCS-CON-2 must not be used.
ResoInput/output Scaling Power Common
Remarks
lution
values
by
mode
[bit]
Hardware
range
PS5311
6
5
100k
100k
1n
100k 1n
100k
AITAC
20 V
AI1
20 V
x10
AI2
40 V
x10
AI3
40 V
AI4
40 V
AO1
5 * mA
AO2
5 * mA
5 * mA
gain: 0.5...5
5 * mA
5 * mA
500
3 4
S2
5 6
7 8
S3
9 10
10
12
11
11
14
13
100
12
S1
100 47.5
X4:1
100n
0V
3
4
5
100 47.5
100n
0V
+/- I-act
3 V = I NDC
R110
0V
+10V
0V
9
10
100
-10V
1 2
1.5 mA
5 mA
S5
3 4
11
1.5 mA
5 mA
0V
12
Encoder supply
X5:1
2
3
S10
4 5 6
S10
+24V 1 2 3
ChB +
10 11 12
+24V 7 8 9
16 17 18
+24V 131415
ChB ChZ +
6
7
8
9
10
Inputs isolated;
Impedance = 120 , if selected
max. frequency 300 kHz
ChA -
4
5
Remarks
ChA +
ChZ V17
Sense Power +
PowerSource
Sense lines for GND and supply to correct voltage drops on cable (only if 5V/12V enc. is in use)
Sense GND
S4
5V/
12V/24V
GND
0.25 A *
0.2 A *
iob3x2_e.dsf
Fig. 6.2/3
III 6-5
3ADW000165R0201_Technical_Data_e_b
DIFFERENTIAL
= twisted
pair
IOB-1/
CON-2
IOB-3
X5:1
ChA+
X5:1
X5:2
ChA-
X5:2
X5:3
ChB+
X5:3
X5:4
ChB-
X5:4
X5:5
ChZ+
X5:5
X5:6
ChZ-
X5:6
B
B
Z
Z
+U
0V
X5:7
Power source
X5:10
X5:8
Sense power
X5:9
X5:9
Sense GND
X5:8
X5:10
SINGLE-ENDED
GND
X5:7
IOB-1/
CON-2
IOB-3
X5:1
ChA+
X5:1
X5:2
ChA-
X5:2
X5:3
ChB+
X5:3
X5:4
ChB-
X5:4
X5:5
ChZ+
X5:5
X5:6
ChZ-
X5:6
B
B
Z
Z
+U
0V
X5:7
Power source
X5:9
X5:9
X5:8
GND
X5:10
X5:8
X5:10
Note:
If the drives direction of rotation is correct (if necessary, correct by exchanging the field connections), the Tacho error message may appear during start-up.
X5:7
65535
Forward
0
III 6-6
3ADW000165R0201_Technical_Data_e_b
Incremental encoder
Two different incremental encoder connections are
available.
- differential connection; pulse encoders generating
either voltage or current signals can be used
- single-ended (push pull) connection; voltage signals
X5:1
SDCS-IOB-1/
CON-2 / IOB-3
120
X5:2
S1:
(S10)
3
2
1
+24V
5 10k
4
SDCS-IOB-1/
CON-2 / IOB-3
120
-U
X5:2
S1:
(S10)
3
2
1
+24V
5 10k
4
GND
CH+
SDCS-IOB-1/
CON-2 / IOB-3
120
CH-
X5:2
1 k
1.2 V
S1:
(S10)
1.5
1.8 V
2.2 k
2.3 V
X5:1
R
U thresh
GND
X5:1
+U
3
2
1
0 ... 50 m
50 ... 100 m
100 ... 150 m
Cable used
1x 0.25 mm
2x 0.25 mm
3x 0.25 mm
12x 0.25 mm
12x 0.25 mm
14x 0.25 mm
+24V
5 10k
4
iob14_e.dsf
Fig. 6.2/6
III 6-7
3ADW000165R0201_Technical_Data_e_b
SDCS-CON-2
X17:
X17:
X6:
X7:
8 x digital
7 x digital
X5:
2 x analog
X4:
4 x analog
1 x Tacho
Fig. 6.3/1
SDCS-IOE-1
X17
H1 H2 H3 H4
90
X3:
Pulsgeber
SDCS-IOE-1
Mechanical Construction
The board is mounted on a plastic housing which
has foot elements (Phoenix Contact series UMK).
The foot elements permit snap-in assembly to a
standard DIN EN rail (EN 50022, 50035).
The dimensions are including the plastic housing.
Plastic housing
X2: X1:
21
43
1
3
S1*
S2 *
2
4 7
2
4
1
3
S3 *
X2
H5 H6 H7
S4 *
X1
8
10
10
14
38
146.3
Jumper coding
Functionallity of analogue inputs
S1
S2
S3
activation of
gain = 1
Ch 500 between
input terminal -10V..+10V
YES
AI5 S1:3-4
gain = 10
-1V..+1V
Jumper
parking
S1:1-2
AI6 S2:3-4
S4
PTC
1.5 mA
1
3
PT100
5 mA *
2
4
1
3
2
4
S2:1-2
S3
1
3
5
7
2
4
6
8
S3
1
3
5
7
2
4
6
8
* default value
ioe1_c.dsf
Fig. 6.3/2
III 6-8
3ADW000165R0201_Technical_Data_e_b
SDCS-IOE-1
2.2k
X1:1
SDCS-CON-2 Software
2.2k H1
47n
Input value
Signal definition
by
681
Remarks
DI9
DI10
0...8 V
16...31 V
DI11
Software
DI12
5
6
DI13
DI14
^ "0" status
=
^ "1" status
=
DI15
9
10
Resolution
[bit]
GND
S1
X2:1
3 4
100k
1n
500 100k 1n
3
4
6
7
8
9
10
S2
3 4
Input/output Scaling
values
by
Hardware
Power Common
mode
range
Remarks
100k
100k
AI5
40 V
AI6
40 V
S3
x10
1 2
S4
3 4
1.5 mA
5 mA
1.5 mA
5 mA
0V
0V
ioe1x1_e.dsf
III 6-9
3ADW000165R0201_Technical_Data_e_b
III 6-10
3ADW000165R0201_Technical_Data_e_b
Communication boards
grey
grey
blue
blue
blue
grey
RxD
blue
Partner
TxD
grey
SDCS-COM-x
Fig. 7.1/1
156.5
V3
SDCS-COM-5
RxD
D7
CH 2
V4
X11
TxD
D8
V1
RxD
TxD
V5
RxD
V6
TxD
*
83.5
CH 1
V2
S1
1
2
3
4
CH 3
D11
conductive support
Jumper coding
Converter
number
Coding for
channel 2
1
S1 2 3
S1 2 3
S1 2 3
4
S1 2 3
4
default value
Fig. 7.1/2
III 7-1
3ADW000165R0201_Technical_Data_e_b
SDCS-AMC-DC
TxD
CH 0
ey
k gr
dar
e
blu
RxD
grey
TxD
D400
RxD
grey
TxD
dark
grey
RxD
5V o.k.
D100
CH 2
ey
k gr
dar
e
u
l
b
green
X10
83.5
grey
CH 3
Prg. running
Fault
Fig. 7.2/1
D200
D105
green
conductive support
red
The SDCS-AMC-DC and the SDCS-AMC-DC Classic boards are identical except the assembly of optical
components for channel 0 and 2.
optical Components
Ch 0
Ch 2
Ch 3
D400
driver current
Communication **
CH0, CH2, CH3
CH0
SDCS-AMC-DC *
10 Mb
5 Mb
10 Mb
other interfaces
ICMC1
30 mA
DDCS
SDCS-AMC-DC Classic *
5 Mb
10 Mb
10 Mb
ICMC1
30 mA
DDCS
SDCS-AMC-DC 2
10 Mb
5 Mb
10 Mb
other interfaces
ICMC2
30/50 mA ***
DDCS/Drive Bus
SDCS-AMC-DC Classic 2
5 Mb
10 Mb
10 Mb
ICMC2
30/50 mA ***
DDCS/Drive Bus
* SDCS-AMC-DC 2, SDCS-AMC-DC Classic 2 are direct replacements of SDCS-AMC-DC and SDCS-AMC-DC Classic
** see additional parameter [71.01]
Color of optical components:
*** 5 Mb blue
maximum 30 mA
*** 10 Mb dark grey maximum 50 mA
Remark: Only channels with the same components (e.g. 10 Mb component) may be
connected to each other.
III 7-2
3ADW000165R0201_Technical_Data_e_b
10 m - AMC-DC / DC 2
D105
D200
CH 3
RxD
TxD
CH 2
RxD
TxD
TxD
RxD
CH 0
D400
X10
SDCS-AMC-DC
or AMC-DC 2
D105
CH 3
RxD
TxD
TxD
RxD
CH 2
D200
X10
SDCS-AMC-DC
or AMC-DC 2
D400
TxD
RxD
CH 0
D200
CH 3
TxD
RxD
CH 2
RxD
TxD
TxD
RxD
CH 0
D400
X10
SDCS-AMC-DC
or AMC-DC 2
D105
20 m - AMC-DC Classic
10 m - AMC-DC / DC 2
20 m - AMC-DC Classic / Classic 2
...
or AMC-DC 2
SDCS-AMC-DC
D200
CH 3
RxD
TxD
RxD
TxD
TxD
RxD
CH 2
D400
CH 0
SDCS-AMC-DC
or AMC-DC 2
D200
CH 3
RxD
TxD
TxD
RxD
CH 2
D400
RxD
TxD
CH 0
or AMC-DC 2
SDCS-AMC-DC
CH 3
TxD
RxD
CH 2
RxD
TxD
TxD
RxD
CH 0
D200
D400
Fig. 7.2/2
20 m - AMC-DC
30 m - AMC-DC 2
TxD
TB 810
FCI
AC80
or AMC-DC2
SDCS-AMC-DC
D200
CH 3
...
RxD
TxD
RxD
TxD
CH 2
D400
CH 0
RxD
TxD
SDCS-AMC-DC
or AMC-DC 2
D200
RxD
CH 3
TxD
RxD
CH 2
D400
CH 0
TxD
RxD
TxD
SDCS-AMC-DC
CH 3
RxD
CH 2
TxD
RxD
TxD
RxD
TxD
CH 0
D200
D400
Fig. 7.2/3
or AMC-DC 2
RxD
amc_1_1_e.dsf
20 m SDCS-AMC-DC
30 m SDCS-AMC-DC 2
TxD
...8
RxD
TxD
0, 1, 2 ... NDBU-95
RxD
TxD
RxD
TxD
RxD
...
amc_1_1_d.dsf
TxD
RxD
AC80
Fig. 7.2/4
III 7-3
3ADW000165R0201_Technical_Data_e_b
Fig. 7.2/7
D200
D400
CH 3
CH 2
CH 0
D200
D400
III 7-4
3ADW000165R0201_Technical_Data_e_b
RxD
TxD
RxD
CH 3
CH 2
CH 0
D200
D400
CH 3
CH 2
CH 0
D200
D400
SDCS-AMC-DC Classic
RxD
TxD
RxD
TxD
RxD
TxD
CH 3
CH 2
CH 0
D200
D400
CH 3
CH 2
CH 0
D200
D400
NISA-03 (PC)
NDPC-12
(Laptop)
NDPA-02
SDCS-AMC-DC Classic
RxD
TxD
RxD
TxD
RxD
TxD
or AMC-DC Classic 2
SDCS-AMC-DC Classic
RxD
TxD
RxD
TxD
RxD
TxD
or AMC-DC Classic 2
...
or AMC-DC 2
or AMC-DC Classic
or AMC-DC Classic 2
TxD
RxD
TxD
RxD
TxD
RxD
APC
SDCS-AMC-DC
...
TxD
RxD
...
TxD
Nxxx-xx
or AMC-DC 2
or AMC-DC Classic
or AMC-DC Classic 2
SDCS-AMC-DC
RxD
TxD
RxD
TxD
RxD
TxD
or AMC-DC 2
or AMC-DC Classic
or AMC-DC Classic 2
Nxxx-xx
TxD
RxD
CH 3
CH 2
CH 0
Fig. 7.2/6
SDCS-AMC-DC
RxD
TxD
RxD
TxD
RxD
TxD
Fig. 7.2/5
TxD
RxD
TxD
RxD
TxD
RxD
TxD
RxD
CH 3
CH 2
CH 0
D200
D400
CH 3
CH 2
CH 0
D200
CH 3
CH 2
CH 0
D200
D400
or AMC-DC 2
SDCS-AMC-DC
RxD
TxD
RxD
TxD
RxD
TxD
SDCS-AMC-DC
or AMC-DC 2
RxD
TxD
RxD
TxD
RxD
TxD
D400
SDCS-AMC-DC
RxD
TxD
RxD
TxD
RxD
TxD
or AMC-DC 2
...
YPQ112 B
amc_1_1_e.dsf
Nxxx-xx
amc_1_1_d.dsf
Fieldbus
amc_1_1_d.dsf
SDCS-AMC-DC
or AMC-DC 2
or AMC-DC Classic
or AMC-DC Classic 2
D200
CH 3
RxD
TxD
RxD
TxD
CH 2
D400
CH 0
RxD
TxD
SDCS-AMC-DC
or AMC-DC 2
or AMC-DC Classic
or AMC-DC Classic 2
D200
CH 3
RxD
TxD
TxD
RxD
CH 2
D400
CH 0
RxD
TxD
SDCS-AMC-DC
D200
CH 3
RxD
TxD
RxD
TxD
CH 2
D400
CH 0
RxD
TxD
or AMC-DC 2
or AMC-DC Classic
or AMC-DC Classic 2
...
Plastic
20 m
SDCS-AMC-DC opt. fibre
SDCS-AMC-DC Classic
30 m
SDCS-AMC-DC 2
SDCS-AMC-DC Classic 2
RxD
...8
RxD
0, 1, 2 ... NDBU-95
TxD
RxD
TxD
TxD
RxD
RxD
TxD
...
...8
TxD
0, 1, 2 ... NDBU-95
TxD
...
RxD
TxD
RxD
TxD
RxD
...
Branching
unit
Branching
unit
Plastic opt. fibre
max. 30 m
or 200 m
HCS
...8
RxD
TxD
0, 1, 2 ... NDBU-95
TxD
RxD
TxD
RxD
...
Branching
unit
Plastic
opt. fibre
max. 30 m
HCS
Silicat
max. 200 m
PC board
TxD
RxD
NISA-03 (PC)
NDPC-12
(Laptop)
NDPA-02
Fig. 7.2/8
amc_1_1_d.dsf
III 7-5
3ADW000165R0201_Technical_Data_e_b
DBU
41
Technical specifications
Optical links:
Master channels
Slave channels
Data rate
94
NDBU-95
TXD
V120
CH8
Driving current
Monitoring
Transmission device
DDCS
BRANCHING
UNIT, 8+1 CH
RXD
V119
TXD
V118
CH7
ADDRESS
8
RXD
S1
V117
TXD
V116
CH6
1
1
RXD
V115
Power supply:
Input voltage
Input current
Monitoring
TXD
V114
CH5
RXD
V113
MBIT/S
++ ++
+ + + + X12
1 2 4
TXD
V112
CH4
RXD
V111
TXD
264
V110
Remark: Only channels with the same components (e.g. 10 Mb component) may be
connected to each other.
CH3
RXD
V109
TXD
V108
CH2
RXD
V107
TXD
V106
CH1
TRANSM
SETTING
+ + + + X2+ + + + X11
RXD
V105
DIS
LONG
MEDIUM
SHORT
TXD
V104
CH0
RXD
V103
TXD
V102
MSTR RXD
V101
Note
For addressing and automatic node numbering of
the drives and branching units see DriveWindow
documentaion.
+5V OK
X1
Fig. 7.3/1
III 7-6
3ADW000165R0201_Technical_Data_e_b
1
2
24 V DC
0V
Field exciters
CONVERTER MODULE
F+
5
7
V1
line
potential !
X14:
80
F-
X1:
SDCS-CON-x
X14:
+ 15 V
X1: 1
S D C S -F E X -1
A4
X14:
9
B3
Fig. 8.1/2
F+
X1: 5
F3
Three phase field exciters DCF 50xB/60x are converter modules themselves, similar to the DCS
501B/601 or DCS 502B/602 additionally a overvoltage protection unit is needed see chapter 8.4.
The AC share of the output DC voltage is measured with a capacitor and an auxiliary rectifier and
used for current monitoring.
Transistor relay is closed when the DC current is
flowing (>0.02 A).
SDCS-FEX-1
130
Fig. 8.1/1
Fig. 8.1/3
Fig. 8.1/4
III 8-1
3ADW000165R0201_Technical_Data_e_b
The field exciter board SDCS-FEX-2 / FEX-2A consists of a power part and a control board, which
connects all components electrically and mechanically to each other. This arrangement has to be
mounted inside the armature converter module beside the electronic power supply SDCS-POW-1.
This is intended to be done for DCS modules of
type C1, C2 and A5, not for A6 and A7 (C4)!
The power part is build up with two power modules.
Each of the modules consists of one diode and one
thyristor, so they are wired up and controlled like a
half controlled bridge.
Conductive support
X1:
D37
F-
F+
5
7
T11
V11
line
potential !
X14:
6
10
T13
90
V13
T1
SDCS-FEX-2
IACT
GND
X20
1
240
Fig. 8.2/1
If Field weakening is needed, actual field current of the motor at top speed must be
higher than 0.3 A
III 8-2
3ADW000165R0201_Technical_Data_e_b
AC Input
T1
DC Output
2k2
Synchronisation
burden adjustment
Control unit
from SDCS-CON-x
via X14:
Fig. 8.2/2
RS 485
Serial link
III 8-3
3ADW000165R0201_Technical_Data_e_b
The half controlled (2-Q) field exciter unit DCF503A0050 consists of the SDCS-FEX-32A board, two
thyristor/diode power modules and auxiliaries (power
supply, line choke). The full controlled (4-Q) field
exciter unit DCF504A-0050 consists of the SDCSFEX-31A board, four anti-parallel thyristor/ thyristor
DCF504A
DCF503A
+
DC
output
AC
supply
Fig. 8.3 /1
DC
output
AC
supply
T1
T1
Fex3x1_d.dsf
U1
Commutation
choke
V23, V24
V11, V12
V13, V14
2
3
4
5
6
7
8
9
V1
X5
C1 (+)
2
1
4 S2
X101
3
GNDB
1
area
X2
5
X100
1
X800
10
LED
4
3 S1
7
X70
1
6
X50
1
X112
X124
275
2
1
X113
X114
8
X20
T1
Line
potential !
SDCS-FEX-31A
SDCS-FEX-32A
1X3 2
9 5 X6
61
Conductive supports
Fex3A_b.dsf
Fig. 8.3/2
not used
X12 X11
D1 (-)
not used
Test mode
extended; Bridge
reversal time
Not used - don't select
If Field weakening is needed, actual field current of the motor at top speed must be higher than 0.3 A
III 8-4
3ADW000165R0201_Technical_Data_e_b
Measured
voltage
Terminal
positive
+5V
+30V
+15V
-15V
+ 5V
X70:1
X70:3
X70:4
X70:6
X100
Ground
X70:2 (GND)
X70:5 (GND)
X70:5 (GND)
X70:5 (GND)
X101:1 (GNDB)
8.3.5 RS232-Port
The RS232 interface is used for download the
'Field exciter firmware package'.
The default settings of this interface are as follows:
Signal level:
Data format:
Message format:
Transmission method:
Baudrate:
Number of Data bits:
Number of Stop bits:
Parity-Bit:
X6:
1
2
3
4
5
6...9
Description
not connected
TxD
RxD
not connected
SGND Signal ground
not connected
5
9
4 V *Iact / IScale
IScale = 3A, 5A, 7A, 9A, 11A, 13A, 15A, 17A, 21A,
27A, 33A, 39A, 45A, 51A
III 8-5
3ADW000165R0201_Technical_Data_e_b
If a SDCS-FEX-2A is used, it will be always recognized as the field exciter Node 1 by the software.
Node 1 or Node 2 must be coded according to the
table below for DCF503A/504A-0050 and for the 3phase field exciters (via parameter). The scan time
for Node 1 = 10 ms, for Node 2 = 100 ms. Field
weakening is not necessarily available for Node 2.
Unit type
Setting X800
Unit type
Setting X800
SDCS-FEX-2A
DCF 503A/504A
SDCS-FEX-2A
DCF 503A/504A
--X800:1 = OFF
--X800:1 = OFF
----DCF 503A/504A
DCF 503A/504A
----X800:1 = ON
X800:1 = ON
The RS485 interface works with a screened twowire cable. The allowed length is 5 m. The wires
have to be connected to the terminals X2:1 and
X2:2 and the screen to X2:3.
U1
SDCSCON-2
V1
DC OUTPUT
C1
D1
PE
X14
SDCSFEX-2A
Armature
controller
SDCSC O N-2
1. D C F503A0050
X14
AC INPUT
DCF503A0050
Total
length
max 5 m
X16:1
X16:2
X16:3
Power supply
Fex3Ax2_c.dsf
Fig. 8.3/5
AC INPUT
U1
AC INPUT
V1
C1
DC OUTPUT
V1
C1
D1
PE
Armature
controller
X16:1
X16:2
X16:3
X800:1=ON
X3:2
U1
D C F503A0050
Field
exciter
Node 2
Node 2
X3:1
SDCSCON-2
2.
X2:1
X2:2
X2:3
DC OUTPUT
D1
PE
DCF503A0050
Total
length
max 5 m
X2:1
X2:2
X2:3
Field
exciter
Node 1
DCF503A0050
Total
length
max 5 m
Node 1
Power supply
X3:1 X800:1=OFF
X3:2
X2:1
X2:2
X2:3
X3:1
Power supply
Field
exciter
Node 2
Node 2
X800:1=ON
X3:2
Fex3Ax3_b.dsf
Fig. 8.3/6
2exec_1cv_b.dsf
Fig. 8.3/4
III 8-6
3ADW000165R0201_Technical_Data_e_b
8.3.7 Diagnosis
FAULT
Definition
8
F81
F82
F83
F84
F85
F86
F88
F89
F90
F91
F92
A81
A88
A90
A91
Parameters added
Up / Download failed
Compatibility Alarm
Parameter restored
PE
X3: 2 1
U1
AC1
SDCS-FEX-31A
SDCS-FEX-32A
V1
4
3
AC2
X2:
1
2
3
4
5
DCF503_4_conv_diagr.dsf
Fig. 8.3/7
D1(-)
C1 (+)
III 8-7
3ADW000165R0201_Technical_Data_e_b
8.3.8 Dimensions
Minimum
Top clearance
Dimensions in mm
Weight appr. 10 kg
all for M6
all for M6
X2
Signal terminals
Serial link
(aux. voltages)
173
LED
1
10
9
6
X6
Sub-D
M6
all for M6
X800
X800
D1
III 8-8
3ADW000165R0201_Technical_Data_e_b
all for M6
M6
Mounting direction
D1 (-)
Minimum
Bottom clearance
3x41=123
C1
C1 (+)
all for M6
V1
V1
U1
U1
Field supply
Converter
Overvoltage
protection
C1(+)
X11
Field supply
Converter
DCF 505
Overvoltage
protection
C1(+)
DCF 501B/502B
DCF 601/602
DCF 501B
DCF 601
D1(-)
X12
DCF 506
X11
M
D1(-)
X12
X6:2 9
X4:1
Overvoltage Protection
DCF506-0140-51
DCF506-0520-51
DCF506-0140-51
DCF506-0520-51
Overvoltage Protection
DCF506-1200-51
DCF506-1500-51
DCF506-1500-71
III 8-9
3ADW000165R0201_Technical_Data_e_b
Diagram
X11
X12
F-
F+
A1
R2
1
X2:1
red
X2:2
grey
X1:3
R1
V1
G2
K2
SDCS-FEP-1 (500 V)
SDCS-FEP-2 (690 V)
R3
AK
K
K1
X1:1
red
X1:2
grey
G1
X2:3
X3:1
X3:2
R4
X4:1
DCF505di_d.dsf
Output X4:1-2
X1
SDCS-FEP-1/FEP-2
X3
line potential !
X2
X4
Fep1_2.dsf
III 8-10
3ADW000165R0201_Technical_Data_e_b
Dimensions
16
75
33.5
342
Overvoltage Protection
DCF 505-0140/0520-51
DCF 505-1200-51
DCF 506-0140/0520-51
Dimensions in mm
Weight appr. 8 kg
350
X4
1
X11 (F+)
M8
X12 (F-)
11
MB_520_a.dsf
7
355
Overvoltage Protection
DCF 506-1200-51
DCF 506-1500-51
DCF 506-1500-71
42
145
20
135
8.5
145
Dimensions in mm
Weight appr. 20 kg
X4
X2
482
SDCS-FEP-1 (500 V)
SDCS-FEP-2 (690 V)
X3
X1
8.5
35
X11
X12
MB_1500_a.dsf
32
40
M8
f. M6
III 8-11
3ADW000165R0201_Technical_Data_e_b
III 8-12
3ADW000165R0201_Technical_Data_e_b
Accessories
9.1
Type
170M 1558
170M 1559
170M 1561
170M 1564
170M 1565
170M 1566
170M 1568
170M 3815
170M 3816
170M 3817
170M 3819
170M 5810
170M 6811
170M 6163
170M 6166
170M 6811
170M 6813
30
21
15
6
4
3
1,.8
0,.87
0,.59
0,.47
0,.37
0,.3
0,.22
0,.15
0,.09
0,.22
0,.15
Fuse F1
Size
Fuse holder
10A 660V UR
21A 660V UR
25A 660V UR
50A 660V UR
63A 660V UR
80A 660V UR
125A 660V UR
200A 660V UR
250A 600V UR
315A 660V UR
400A 660V UR
500A 660V UR
700A 660V UR
900A 660V UR
1250A 660V UR
700A 660V UR
900A 660V UR
0
0
0
0
0
0
0
1
1
1
1
2
3
*
*
3
3
OFAX 00 S3L
OFAX 00 S3L
OFAX 00 S3L
OFAX 00 S3L
OFAX 00 S3L
OFAX 00 S3L
OFAX 00 S3L
OFAX 1 S3
OFAX 1 S3
OFAX 1 S3
OFAX 1 S3
OFAX 2 S3
OFAX 3 S3
170H 3006
170H 3006
OFAS B 3
OFAS B 3
L1 L2 L3
F1
Indicator
Size
0
1
2
3
6
Fuse1_a.dsf
b
50
69
69
68
c
35
45
55
76
d
21
45
55
76
e
15
20
26
33
Remark:
Given dimensions may be exeeded in some cases.
Please take them only for information.
10
a
78,5
135
150
150
OFAX 00 S3L
OFAX 1 S3
OFAX 2 S3
OFAX 3 S3
OFAS B 3
Protection
148x112x111
250x174x123
250x214x133
265x246x160
250x246x136
IP20
IP20
IP20
IP20
IP00
110
A-A
M8
M10
M8
27
64
60
85
205
180
OFASB3
H
40
170H3006_a.dsf
M10
III 9-1
3ADW000165R0201_Technical_Data_e_b
77
Fuse
holder
ND 01
ND 02
ND 03
ND 04
ND 05
ND 06
ND 07
ND 08
ND 09
ND 10
ND 11
ND 12
ND 13
ND 14
ND 15
ND 16
Choke
L
[H]
Irms
[A]
Ipeak
[A]
rated
Weight
Voltage
[UN]
[kg]
512
250
300
168
135
90
50
56.3
37.5
25.0
33.8
18.8
18.2
9.9
10.9
6.1
18
37
37
55
82
102
184
196
245
367
326
490
698
930
1163
1510
27
68
68
82
122
153
275
294
367
551
490
734
1047
1395
1744
2264
500
500
600
500
600
500
500
600
500
500
600
500
690
500
690
500
2.0
3.0
3.8
5.8
6.4
7.6
12.6
12.8
16.0
22.2
22.6
36.0
46.8
46.6
84.0
81.2
5
7
9
10
5
7
45
45
50
80
80
95
170
100
190
210
16
22
20
33
30
41
90
130
140
185
185
290
160
300
680
650
DCS...-0025
DCS...-0050
DCS...-0050
DCS...-0075
DCS...-0110
DCS...-0140
DCS...-0250
DCS...-0270
DCS...-0350
DCS...-0520
DCS...-0450
DCS...-0820 (2-Q)
DCS...-0820 (4-Q)
DCS...-1200
DCS...-1500
DCS...-2000
X, Y, Z
A, B, C
C
A, B, C
60
0
0
100
to converter
X, Y, Z
to mains
a
a1
d
Type
a1
ND 01
ND 02
ND 03
ND 04
ND 05
ND 06
120
120
148
148
148
178
100
100
125
125
125
150
130
130
157
157
157
180
48
58
63
78
78
72
65
65
80
80
80
90
116
116
143
143
143
170
4
4
5
5
5
5
8
8
10
10
10
10
ND1_to_6_a.dsf
III 9-2
3ADW000165R0201_Technical_Data_e_b
mm
6
10
10
16
25
35
H 2
F 0.3
A
E2
C1
K
E 2
A 2
G 4
15
C 1
3 AST 4 78 2 23 D5
3AFE 10014603
0 .0 1 88 mH
4 90 A
I ma x 7 34 A
A
7
15
A-A
ND7_to_12_c.dsf
F 0.3
B 1
Type
ND 07, 08
ND 09
ND 10, 11
ND 12
A
285
327
408
458
B
230
250
250
250
C
86
99
99
112
C1
100
100
100
113
E
250
292
374
424
F
176
224
224
224
G
65
63
63
63
H
I
K
80
9x18 385
100 9x18 423
100 11x18 504
100 13x18 554
L
232
280
280
280
busbar
20x4
30x5
60x6
40x6
1512
45
30
20
18
45
40
140
ND13_14_c.dsf
3901
147
(6x) 10x18
40
A-A
15
30
50
150 2
A
13
13
30
60
13
15
290 1
316 0.3
13
342 2
10
A-A
224 0.3
154 4
30
123 2
147
15
80
45
176 5
100
440 2
100
140
40
18x13(3x)
90
140 2
1812
III 9-3
3ADW000165R0201_Technical_Data_e_b
48
A
ND15_16_c.dsf
Choke
L
[H]
Irms
Line AC [A]
Ipeak
[A]
1000
600
450
350
250
160
120
90
70
60
50
40
35
18.5
37
55
74
104
148
192
252
332
406
502
605
740
27
68
82
111
156
220
288
387
498
609
753
805
1105
ND 401
ND 402
ND 403
ND 404
ND 405
ND 406
ND 407
ND 408
ND 409
ND 410
ND 411
ND 412
ND 413
rated
Weight
Voltage
[kg]
[UN]
400
400
400
400
400
400
400
400
400
400
400
400
400
3.5
7.5
11
13
19
22
23
29
33
51
56
62
75
Power loss
Fe
Cu
[W]
[W]
13
13
42
78
91
104
117
137
170
260
260
280
312
Load
DC curr. 1
35
50
90
105
105
130
130
160
215
225
300
335
410
22.6
45
67
90
127
179
234
315
405
495
612
738
900
A
160
200
B
190
220
C
75
105
D
80
115
E
51
75
F
175
200
G
7
7
H
9
9
A X
170
Y
Terminals:
C Z
H
tin-coated
Y
G+5
F1
E 2
III 9-4
3ADW000165R0201_Technical_Data_e_b
Load
DC curr.2
18
36
54
72
101
143
187
252
324
396
490
590
720
A
220
220
235
255
255
285
B
230
225
250
275
275
285
C
120
120
155
155
155
180
D
135
140
170
175
175
210
E
100
100
125
125
125
150
F
77.5
77.5
85
95
95
95
G
7
7
10
10
10
10
H
9
9
9
9
9
9
K
6.6
6.6
6.6
9
11
11
H
tin-coated
K AL
A
G+5
50
45
10
E 2
F 2
C
D
A
320
345
345
385
445
B
280
350
350
350
350
C
180
180
205
205
205
D
210
235
270
280
280
E
150
150
175
175
175
F
95
115
115
115
115
G
10
10
12
12
12
H
11
13
13
13
13
K
11
14
2x11
2x11
2x11
H
tin-coated
C
X
K AL
A
X
G+6
12
F 2
E 2
C
D
III 9-5
3ADW000165R0201_Technical_Data_e_b
9.2.1 Autotransformer T3
Type
Transformer's
secondary current
Isec
Weight
Power loss
Fuse F3
[kg]
PV [W]
[A]
T 3.01
T 3.02
T 3.03
T 3.04
T 3.05
6 A
12 A
16 A
30 A
50 A
15
20
20
36
60
65
100
120
180
250
10
16
25
50
63
T 3.11
T 3.12
T 3.13
T 3.14
T 3.15
6 A
12 A
16 A
30 A
50 A
15
20
30
60
60
80
125
150
230
320
10
16
20
50
63
690 V transformer input cannot be used for the field converters SDCS-FEX-1 and SDCSFEX-2 (isolation only 600 V max.)
Table 9.2/1: Autotransformer data
)
F3
F3
T3
T3
Type
T 3.01 / T 3.11
T 3.02 / T 3.12
T 3.03
T 3.13
T 3.04
T 3.14
T 3.05 / T 3.15
/
A
,
*
A
210
210
B
110
135
C
112
112
D
75
101
h
e
240 10x18
240 10x18
G
95
95
230
260
295
150
150
175
124
144
176
118
123
141
270 10x18
330 10x18
380 12x18
95
95
95
ND30
16
Weight
Ipeak
[A]
16
[kg]
1,1
Power
loss
[W]
8
[mm]
1000
Type
2
max 70
4.5
55
37
max 80
52
III 9-6
3ADW000165R0201_Technical_Data_e_b
F2
Type
T2
T2
230 V
115 V
T2_a.dsf
0V
Power
Weight
Fuse F2
Isec
[VA]
[kg]
[A]
[A]
1400
15
16
Power loss
[W]
6 (0...230 V)
12 (0...115 V)
100
35
0
115
230
0
380
400
415
450
500
525
575
600
660
690
150
6.3 mm Faston
106
128
125
148
100 +-5
T2_dim.dsf
Application hint:
230 V
F2
T2
230 V
115 V
T2_a.dsf
0V
Power
Weight
Fuse F2
Power loss
[VA]
[kg]
[A]
[W]
460
13
20
III 9-7
3ADW000165R0201_Technical_Data_e_b
Cp
I L1
I L2
I L3
residual_curr_detect.dsf
30
P1
P2
M4*8
S1 S2
25
89
84,5
30
30
40
25
CT
25
223
33
40
273 0,5
PWS10004_dim.dsf
III 9-8
3ADW000165R0201_Technical_Data_e_b
P1
M4*8
P2
S1 S2
55
198
max
190
30
30
30
CT
55
50
340
55
55
30
450
PWS33001_dim.dsf
left holder
18
holes for M6
drilling pattern
(free space)
CT
holes for M6
drilling pattern
(free space)
69.
left holder
CT
Hints
After having all parts installed, please make sure:
- jumper S1 on SDCS-IOB-3 is in position 11 - 12 and 13 - 14
no cables connected to terminals X3:9 and X3:10 at SDCS-IOB-3 board
- select AI4 for this monitoring function by parameter
activate that monitoring function via parameter
define the threshold in amps via parameter
if necessary delay the error message via parameter to avoid actions caused by disturbance or similar
III 9-9
3ADW000165R0201_Technical_Data_e_b
Filter type
max.
voltage
IN
[V]
[A]
Terminals
for wires
with max.
dimension
[mm] *
Weight
PE
connection
[kg]
NF3-440-25
NF3-440-50
NF3-440-64
NF3-440-80
NF3-440-110
440
440
440
440
440
25
50
64
80
110
4
10/16
10/16
25/35
50
3.0
3.1
3.1
9.5
9.5
M6
M6
M6
M10
M10
NF3-500-25
NF3-500-50
NF3-500-64
NF3-500-80
NF3-500-110
NF3-500-320
500
500
500
500
500
500
25
50
64
80
110
320
3.0
3.1
3.1
9.5
9.5
21.0
M6
M6
M6
M10
M10
M10
NF3-500-600
500
600
4
10/16
10/16
25/35
50
Bar with
11mm hole
Bar with
11mm hole
22.0
M10
NF3-690-600
690
600
22.0
M10
NF3-690-1000
690
1000
28
M12
NF3-690-1600
690
1600
34
M12
NF3-690-2500
690
2500
Bar with
11mm hole
Bar with 14
mm hole
Bar with 2x
14 mm hole
Bar with 4x
14 mm hole
105
M16
III 9-10
3ADW000165R0201_Technical_Data_e_b
115
120
20
19.25
20
LOAD
LINE
136
150
6.4
200
17
250
65
90
400
170
130
LINE
LOAD
15x6.5
350
373
III 9-11
3ADW000165R0201_Technical_Data_e_b
90
300
(60)
(60)
35
210
210
30
180 0.5
180 0.5
120
260
235 1
L3
Load
L2
Line
L3
L2
L1
L1
240 1
12
40 1
15
85 0.5
15
40 1
115
15
25
3607
11
M10 x 30
350
(60)
(60)
40 1.5
4102.5
15
85 0.5
115
15
30
11
30
1
12
40 1.5
15
120
235 1
260
L1
35
L3
Load
L2
Line
L3
L2
L1
290 1
M10 x 30
III 9-12
3ADW000165R0201_Technical_Data_e_b
III 9-13
3ADW000165R0201_Technical_Data_e_b
Filter type
max.
voltage
IN
[V]
250
250
250
250
250
NF1-250-8
NF1-250-12
NF1-250-20
NF1-250-30
NF1-250-55
Weight
[A]
Terminals
for wires
with max.
dimension
[mm] *
8
12
20
30
55
4
4
4
10/16
10/16
0.7
0.9
1.0
1.0
1.8
PE
connection
[kg]
M6
M6
M6
M6
M6
84.5
10
18
105
LOAD
4.4
LINE
95
51
99.5
138.5
III 9-14
3ADW000165R0201_Technical_Data_e_b
57
84.5
20
16
95
105
LOAD
4.4
LINE
51
19
148
57
115
85
20
13
LOAD
LINE
100
115
6.4
17
231
60
III 9-15
3ADW000165R0201_Technical_Data_e_b
NF3-xxx-25
NF3-xxx-50
NF3-xxx-64
NF3-xxx-80
NF3-xxx-110
NF3-xxx-320
NF3-xxx-600
Thermal Limit Current
The thermal time constant of the converter is smaller than the thermal time constant of the filter, if the filter is chosen according to the tables in appendix A.
In particular cases (e.g. a special load diagram as shown in the figure below the
required filter current can be calculated with the following equation:
1
2
2
2
( I1 t1 + I 2 t2 + ... + I n tn ) .
T
IDC
I1
I1
I3
I2
I4
t1
t3
t2
t4
Environmental Conditions
Ambient operating temperature: 0+40 C
Derating:
above 40 C same derating as
for the converter
Storage temperature:
-25+80 C
Cooling method:
natural air cooling
III 9-16
3ADW000165R0201_Technical_Data_e_b
Appendix A
Optical cables
Connector
plug
plug
plug
plug
FSMA
cable length
Ident. no.
Fig.
0.5...20 m
0.5...20 m
30...50 m
50...200 m
10...100 m
3ADT 693324
3ADT 693318
3ADT 693355
3ADT 693356
3ADV 300002
1
2
3
4
5
Figure 1
L
black
Figure 2
L
blue
black
black
blue
blue
L
orange
orange
5 mm
black
black
Figure 4
L
blue
blue
8 mm
red
red
Figure 3
Figure 5
green
green
red
red
IIIIIIA-1
9-17
3ADW000165R0201_Technical_Data_e_b
DCS 400
III 9-18
Since we aim to always meet the latest state-of-theart standards with our products, we are sure you
will understand when we reserve the right to alter
particulars of design, figures, sizes, weights, etc. for
our equipment as specified in this brochure.
*165R0201A5090000*
*165R0201A5090000*
3ADW000165R0201_Technical_Data_e_b