Professional Documents
Culture Documents
Proceedings of International Conference on Advances in Applied Engineering and Technology 2015, May 14-16, 2015.
4. HARMONIC WAVES
ADVANTAGES
INVERTER
OF
CASCADED
H-BRIDGE
PROPOSED SYSTEM
Proceedings of International Conference on Advances in Applied Engineering and Technology 2015, May 14-16, 2015.
7.
COMPONENTS USED
Proceedings of International Conference on Advances in Applied Engineering and Technology 2015, May 14-16, 2015.
Proceedings of International Conference on Advances in Applied Engineering and Technology 2015, May 14-16, 2015.
12. CONCLUSION
A DSTATCOM with five levels Cascaded H-Bridge inverter is
investigated.
Mathematical model for single H-Bridge inverter is developed
which can be extended to multilevel H-Bridge.
The source voltage , load voltage , source current,
load current, power factor simulation results under nonlinear
loads are presented.
Total Harmonics Distortion reduced to 48.5%.
REFERENCES
[1] Han, Senior Member, IEEE, B. Bae, H. Kim and S.
Baek, Combined Operation of Unified Power-Quality
Conditioner with Distributed Generation, IEEE Transactions
on power delivery, vol. 21, no. 1, January 2006.
[2] Mauricio Aredes, Klemens Heumann, Edson H.
Watanabe, An Universal Active Power Line Conditioner,
IEEE Transactions on Power Delivery, Vol. 13, No. 2, April
1998.
[3] Javier A. Munoz, Jose R. Espinoza, Luis A. Moran and
Carlos R.Baier, Design of a Modular UPQC Configuration
Integrating a Components Economical Analysis, IEEE
Transactions on power delivery, vol. 24, no. 4, October 2009.
[4] B. Singh, and K. Al-Haddad, A review of active filters
for power quality improvement,IEEE Transactions on
Industrial Electronics, vol. 46, no. 5, pp. 960-971, Oct. 1999.
Proceedings of International Conference on Advances in Applied Engineering and Technology 2015, May 14-16, 2015.
[10]
H. Fujita, and H. Akagi, A practical approach
to harmonics
compensation in power systems series
connection of passive and active filters, IEEE Transactions
on Industry Applications, vol. 27, no. 6, pp. 1020-1025, Nov.
1991.
About the authors
P.K.Mani has completed his B.E.
Electrical and Electronics Engineering
and M.E. Power Systems Engineering at
Anna University, Chennai. At present he
is working as Associate Professor in
Electrical and Electronics Engineering
Dept, Vel Tech Multitech Dr.Rangarajan
Dr.SakunthalaEngineering college, Chennai-600062.Currently
he is doing Ph.D in Veltech Dr.RR&Dr.SRTechnical
University in the field of power quality. Mobile. No: +91
9445260989. Email: mani_lotus@yahoo.com.