Surface Safety Valve

Fail-safe gate valve for testing wells with


high flow rates, high pressures, or H2S
Applications

Testing oil and gas wells with high flow


rates, high wellhead pressures, or the
presence of H2S
Wells with hazard operational analysis
needing a surface pressure barrier in
addition to the primary ormaster valve

Benefits

Prevent overpressure conditions


on downstream equipment
Provide immediate well closure in the
event of downstream equipment failure
Ensure reliable shut-in during harsh
environment operations
Reduce personnel exposure
in emergencies
Comply with environmental regulations
and reduce environmental risk

Features

Fail-safe remote activation and automatic well closure when loss of control
pressure occurs
Double metal-to-metal seals for
reliability in harsh environments

Surface safety valve.

Normally equipped with hammer


unions, but can be fitted with Grayloc
or API-6A flanges

The surface safety valve (SSV) is a hydraulically actuated fail-safe gate valve for testing oil and
gas wells with high flow rates (>8,000 bbl/d [>1,280 m3/d] or 30,000,000 ft3/d [>850,000 m3/d]), high
pressures (>5,000 psi [>34 MPa]), or the presence of H2S. The SSV is used to quickly shut in
the well choke manifold upstream in the event of overpressure, failure, a leak in downstream
equipment, or any other well emergency requiring an immediate shut-in.

Compliance with API-6A (PSL-2 or 3,


PR2), H2S (NACE MR0175), and
Fluid Class DD specifications

The SSV is remotely operated by an emergency shutdown device (ESD), which can be triggered
automatically by high- or low-pressure pilot actuators. If an emergency occurs, this feature
reduces the possibility of personnel injuries.
A number of SSV models are available for different well conditions (pressures, temperatures,
and flow rates) and with various connections, such as Grayloc or API-6A flanges. All SSV
models have interchangeable crossover connections and are protected by a compact,
removable lifting frame.
The SSV uses a proven metal-to-metal, double-sealing design for harsh environment operations
and complies with all applicable environmental requirements. All SSVs are manufactured under
Type Approval or Design Verification Review and provided with a Certificate of Conformity and
full quality file.

Surface Safety Valve


Specifications
Model
Nominal
Size, in
SSV-F
SSV-GB
SSV-GH
SSV-GK
SSV-G
SSV-GHC
SSV-GC
SSV-GCB
SSV-GCC
SSV-GCD
SSV-GL
SSV-HD
SSV-HF

318
2116
3116
3116
3116
3116
4116
4116
4116
4116
518
3116
3116

Working
Pressure,
psi [MPa]
5,000 [34]
10,000 [69]
10,000 [69]
10,000 [69]
10,000 [69]
10,000 [69]
10,000 [69]
10,000 [69]
10,000 [69]
10,000 [69]
10,000 [69]
15,000 [103]
15,000 [103]

Connectors, Certifications, and Codes


Model
Hydraulic Actuator
Port
Maximum Working
Pressure, psi [MPa]
12-NPT
3,000 [21]
SSV-F

Test Pressure,
psi [MPa]

Temperature Class,
degF [degC]

Inlet/Outlet
Connections

10,000 [69]
15,000 [103]
15,000 [103]
15,000 [103]
15,000 [103]
15,000 [103]
15,000 [103]
15,000 [103]
15,000 [103]
15,000 [103]
15,000 [103]
22,500 [155]
22,500 [155]

20 to 250 [29 to 121]


20 to 250 [29 to 121]
20 to 350 [29 to 177]
20 to 250 [29 to 121]
20 to 250 [29 to 121]
20 to 350 [29 to 177]
20 to 250 [29 to 121]
20 to 250 [29 to 121]
50 to 350 [46 to 177]
20 to 350 [29 to 177]
20 to 250 [29 to 121]
20 to 350 [29 to 177]
20 to 350 [29 to 177]

3-in Fig 1002 Female/Male


2-in Fig 1502 Female/Male
3-in Fig 1502 Female/Male
3-in Fig 1502 Female/Male
3-in Fig 1502 Female/Male
3-in Fig 1502 Female/Male
API Flange 4116BX155
API Flange 4116BX155
API Flange 4116BX155
API Flange 4116BX155
Grayloc 6 G52
API Flange 3116BX154
API Flange 3116BX154

Hard Facing
(Colmonoy)

Special Sand
Service

Dimensions
(L W H), ft [m]

Weight,
lbm [kg]

Applied Codes

#5

No

3.77 1.97 3.87


[1.15 0.60 1.18]
1.27 0.79 1.97
[0.39 0.24 0.60]
4.27 1.97 3.87
[1.30 0.60 1.18]
4.27 1.97 3.87
[1.30 0.60 1.18]
4.27 1.97 3.87
[1.30 0.60 1.18]
4.27 1.97 4.32
[1.30 0.60 1.30]

1,102 [500]

4.27 1.97 4.59


[1.30 0.60 1.40]
4.27 1.97 4.59
[1.30 0.60 1.40]

1,770 [803]

4.27 1.97 4.59


[1.30 0.60 1.40]
4.33 2.00 4.92
[1.30 0.60 1.50]

1,770 [803]

5.08 1.97 5.11


[1.55 0.60 1.56]
4.27 1.97 4.07
[1.30 0.60 1.24]
4.27 1.97 4.72
[1.30 0.60 1.44]

3,000 [1,361]

API-6A (PSL-2, PR2), H2S (NACE


MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072,
PED 97/23, CE marked
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072,
PED 97/23, CE marked
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072,
PED 97/23, CE marked
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072
API-6A (PSL-3, PR2), H2S (NACE
MR0175), DNV Rules, BS 7072,
PED 97/23, CE marked

SSV-GB

12-NPT

3,000 [21]

#75

Yes

SSV-GH

12-NPT

3,000 [21]

#75

No

SSV-GK

12-NPT

3,000 [21]

#75

No

SSV-G

12-NPT

3,000 [21]

#75

No

SSV-GHC

12-NPT

5,000 [34]

#75

No

SSV-GC

12-NPT

3,000 [21]

#75

No

SSV-GCB

12-NPT

3,000 [21]

#75

No

SSV-GCC

12-NPT

5,000 [34]

#75

Yes

SSV-GCD

12-NPT

5,000 [34]

#75

No

SSV-GL

12-NPT

3,000 [21]

#75

No

SSV-HD

12-NPT

3,000 [21]

#75

No

SSV-HF

12-NPT

5,000 [34]

#75

No

Skid Temperature
Class,
degF [degC]
20 [29]
20 [29]
20 [29]
20 [29]
20 [29]
20 [29]
20 [29]
20 [29]
50 [46]
20 [29]
20 [29]
20 [29]
20 [29]

850 [386]
1,200 [544]
1,200 [544]
1,200 [544]
1,200 [544]

1,770 [803]

2,100 [953]

1,500 [680]
2,100 [953 ]

Part Number
P579050
P490837
P798109
P497560
P579049
100368524
P490007
100131104
100244512
100441762
100176331
P792386
100443423

Det

Norske Veritas
to British Standard Code of Practice for Inspection and Repair of Offshore
Conformit Europenne
Complies with European Pressure Equipment Directive 97/23
Complies

*Mark of Schlumberger
Other company, product, and service names
are the properties of their respective owners.
Copyright 2011 Schlumberger. All rights reserved. 10-TS-0016