Professional Documents
Culture Documents
REACH PUREIT AT
1860-210-1000
www.pureitwater.com
Congratulations!
~YmB!
Welcome to the Pureit Family! We thank you for the trust you
have shown in our product and we guarantee you that our
product will live up to your expectations. Pureit is trusted by
millions of users around the world for providing safe drinking
water for their loved ones.
CONTENTS
gyMr
Pureit advantages
13
No gas
Auto Shut-Off
AmQ>mo eQ>-Am$
No boiling
Easy maintenance
No electricity
AmgmZ aI aImd
No plumbing
No chlorine taste
No A.M.C
mH${VH$ dmX
No undesirable odour
Im JoS> bmpQ>H$
Top Cover
Q>mn H$da
Top Chamber
Q>mn M~a
Carbon Polisher
H$m~Z nm{bea
Transparent Chamber
Q>mgna|Q> M~a
Tap
Zb
Pedestal
noS>oQ>b
mBH$mo$mB~a
ES>d
m
an
S>
g
esh
Adv
icrofibe
Removes
visible dirt and
precipitated
metallic
impurities.
oe
dM
ce
er
mk
cha
r g e d Me m
an
e
Mi
H$b mogoga
O{
hm{ZH$maH$
dmag Ama ~oQ>o[am H$mo
b ~ZmH$a Xa H$aZo Ho$
{bE mmo{JH$
H$sQ>mUy ZmeH$ VH$ZrH$
H$m moJ H$aVm h &
mBH
br
Purifies
the water again
and removes
harmful parasites
giving the assurance
of double
protection.
Uses
Programmed
Germkill Technology
to target and remove
harmful viruses and
bacteria.
Ca
ro
ill Processo
$moMmS> o~oZ
rbo
n Polishe
Removes
harmful parasites,
pesticides and
chlorine, making the
water clear, odorless
and natural
tasting.
nm{bea
H$m~Z
hm{ZH$maH$ naOrdr,
H$sQ>ZmeH$ VWm bmoarZ
H$mo {ZH$mbVm h Ama nmZr
H$mo dN>, JYhrZ ~Zm Ho$
mH${VH$ dmX XoVm h &
Open the box. Remove the Top Cover and keep it aside.
Remove and discard the thermocol.
S>~o H$mo Imob| & Q>mn H$da H$mo {ZH$mbo Ama ~mOy | aIo &
Wm}H$mob H$mo {ZH$mbH$a |$H$ X| &
There is a bellow pump in the Top Chamber. Keep it in a safe place as you will need it later for cleaning.
Q>mn M~a | EH$ ~obmo nn h & Bgo gwa{jV WmZ na aI X| mo{H$ g$mB Ho$ g AmnH$mo BgH$s OaV nS>oJr &
CAUTION
10
hmWm| H$mo AN>r Vah go Ymo| & Q>mn Mo~a Ho$ AXa aI|
Wbr go mBH$moMmOS> o~oZ H$mo {ZH$mb| &
11
After fitting the Microcharged Membrane assembly to the Cleansing Collection Chamber, do not rest the
assembly on a flat surface.
mBH$moMmOS> o~oZ Ago~br H$mo boqOJ H$boeZ Mo~a | AN>r Vah go bJmZo Ho$ ~mX Bgo gmZ gVh na Zm aIo &
CAUTION
Please remove the paper sleeve from the Cleansing Collection Chamber before use.
mo[aQ> H$m CnmoJ H$aZo go nohbo H$nm nona brd H$mo boqOJ H$boeZ Mo~a go {ZH$mb| &
12
Pour in water till the top of the Top Chamber and drain out all the
water that collects in the Transparent Chamber. Place the lid on the Top
Cover. Pureit Advanced is now ready for use from second cycle onwards.
Q>mn Mo~a Ho$ D$na VH$ nmZr ^ao Ama Q>mgna|Q> Mo~a | BH$Q>R>m hE nmZr
H$mo {ZH$mb X| & Q>mn H$da H$mo {bS> go T>H$ X| & mo[aQ> ES>dmgS> Xgao
gmBH$b go CnmoJ H$aZo Ho$ {bE Vma h &
Please note that the first cycle will not give full 9L of water in the Transparent Chamber since some water gets
stored in the Cleansing Collection Chamber and the Top Chamber.
H$nm OmZ b| {H$ nhbo gmBH$b go mam nyam 9 brQ>a nmZr Q>mgna|Q> Mo~a | Zhr {boJm m|{H$ WmoS>m gm nmZr boqOJ H$boeZ
Mo~a Ama Q>mn Mo~a | Om hmoVm h &
13
O~ B{S>Ho$Q>a Xem ahm hmo go$X m hH$m gm bmb, BgH$m Vb~ O{H$b
{H$Q> (Or Ho$ Ho$) H$m H$a ahm h Ama CnmoJ Ho$ [bE gwa{jV h &
When Indicator shows mostly red, the Germkill Kit (GKK) is
nearing its end of life and its time to buy a new
Germkill Kit (GKK).
O~ B{S>Ho$Q>a Xem ahm hmo A{YH$Va bmb, BgH$m Vb~ O{H$b {H$Q>
(Or Ho$ Ho$) I hmoZo dmbm h Ama Zm O{H$b {H$Q > (Or Ho$ Ho$)
When Indicator shows fully red, the Germkill Kit (GKK) has
exhausted and it is time to replace it.
O~ B{S>Ho$Q>a Xem ahm hmo nyar Vah bmb, BgH$m Vb~ O{H$b {H$Q>
(Or Ho$ Ho$) H$s jVm I hmo Jr h Ama O{H$b {H$Q> (Or Ho$ Ho$)
Once the Germkill Life Indicator turns fully red, please replace the Germkill Kit (GKK) immediately. As an
additional measure of safety, Auto Shut-Off mechanism of the Pureit Advanced, shuts off the supply of purified
water which ensures that no member of your family accidentally drinks unsafe water.
O{H$b bmB$ B{S>Ho$Q>a nyar Vah bmb hmo OmZo na H$nm O{H$b {H$Q> (Or Ho$ Ho$) H$mo VwaV ~Xb X| & gwajm Ho$ A{V[a$ ^amogo Ho$
Vma na mo[aQ> H$m AmYw{ZH$ AmQ>mo eQ> Am$ V moar$m {H$o hE nmZr H$s gbmB ~X H$a XoVm h {Oggo gw[ZpMV hmoVm h H$s AmnHo$
CAUTION
There is an Auto Shut-Off overflow port provided on the Germkill Life Indicator cover. When the Germkill
Life Indicator is red, you might observe overflow from this port. Please replace the Germkill Kit(GKK). Do
not pour any more water in the Top Chamber to avoid further spillage.
O{H$b bmB$ B{S>Ho$Q>a H$da na EH$ AmQ>mo eQ>-Am$ ma XmZ {H$m Jm h & O~ O{H$b bmB$ B{S>Ho$Q>a bmb aJ H$m hmo OmVm
h, V~ Amn Bg ma go A{Vdmh XoI gH$Vo h & H$nm O{H$b {H$Q> (Or Ho$ Ho$) H$mo ~Xb X| & A{YH$ ZwH$gmZ go ~MZo Ho$ {bE Q>mn
14
1860-210-1000
www.pureitwater.com
Visiting a shop
XH$mZ go
15
Microcharged Membrane
mBH$moMmOS> o~Z
CAUTION
Germkill Processor
O{H$b mogoga
Carbon Polisher
H$m~Z nm{bea
There are multiple Pureit Germkill Kit(GKK) available. Please buy the one that is
recommended for your Pureit Advanced model.
mo[aQ> Ho$ AZoH$ H$ma Ho$ O{H$b {H$Q> (Or Ho$ Ho$) CnbY h. H$nm AmnHo$ mo[aQ> mS>b |
hmoZo dmbr O{H$b {H$Q> (Or Ho$ Ho$) hr IarX| &
{$Q>
16
17
Do not clean the hole in the Top Chamber with sharp objects.
Q>mn Mo~a Ho$ N>oXm| H$mo ZwH$sbo dVw go gm$ Z H$a| &
CAUTION
18
19
Do not remove the Microcharged Membrane assembly without emptying water from the
Cleansing Collection Chamber.
CAUTION
boqOJ H$boeZ Mo~a go nmZr Imbr {H$E {~Zm mBH$moMmS> o~oZ Ag|br H$mo Z {ZH$mb| &
20
11
12
21
Close the mouth of the carbon block with one hand and squeeze the Bellow
Pump with the other hand to force the water through the carbon block. You
can see dirt coming out of the carbon block. Repeat procedure 5-6 times.
H$m~Z bmH$ Ho$ wh H$mo EH$ hmW go ~X H$ao Ama ~obmo nn H$mo Xgao hmW go X~m|
{Oggo {H$ H$m~Z bmH$ | nmZr H$m X~md ~T>o & Amn XoI|Jo {H$ H$m~Z ~bmH$ go
b ~hma {ZH$mb ahm h & Bg {H$m H$mo 5-6 ~ma XmohamE
14
You may observe some amount of water coming back through the Below Pump which can be pushed into the
Carbon Polisher again. Please clean the Carbon Polisher with the Bellow Pump multiple times for best results.
CAUTION
Amn XoI|Jo H$s WmoS>r m | nmZr ~obmo nn go ~mha Am ahm h {Ogo nwZ H$m~Z nm{bea | YHo$bm Om gH$Vm h & H$m~Z
nm{bea H$mo H$B ~ma ~obmo nn go Ymo b| {Oggo AN>m n[aUm {bo &
22
16
17
23
18
Now hold the Microcharged Membrane base and squeeze the Bellow
Pump to force water out of the Microcharged Membrane assembly. You
can see dirt coming out of the membrane. Repeat procedure 5-6 times.
A~ mBH$moMmS> o~oZ Ho$ Vb H$mo nH$S>| Ama ~obmo nn H$mo X~m|, Vm{H$ nmZr nyar
VoOr go mBH$moMmS> o~oZ Ago~br go ~mha {ZH$b| & Amn o~oZ go {ZH$bVr hB
JXJr H$mo XoI gH$Vo h & Bg H$m{dmr H$mo 5-6 ~ma Xmoham| &
In case your water quality is very bad and the flow rate does not improve on cleansing the Advanced Microfiber Mesh and the
Carbon Polisher you need to clean the Microcharged Membrane as shown above.
AJa nmZr ~hV mXm Iam~ hmo Ama ES>dmgS> mBH$mo$mB~a oe H$m~Z nm{bea H$s g$mB Ho$ ~mX ^r nmZr H$m ~hmd VoO Zm hmo Vmo {$a
While cleaning the Microcharged Membrane, please ensure your hands are germ free.
CAUTION
mBH$moMmS> o~oZ gm$ H$aVo d$ mZ aI| {H$ AmnHo$ hmW H$sQ>mUw w$ hm| &
24
21
25
23
26
25
boqOJ H$boeZ Mo~a Ho$ D$na Q>mn Mo~a H$mo aI| &
Q>mn Mo~a Ho$ D$na Q>mn H$da Ama Q>mn {bS> H$mo aI| &
27
Clean the mouth of the tap with dilute disinfectant like bleach/hypochlorite (50 ppm available chlorine). Pour
in water till the top of the Top Chamber and drain out all the water that collects in the Transparent Chamber.
Refill the Top Chamber. Pureit Advanced is now ready for use from second cycle onwards.
28
DOs
Clean the Top Lid, the Top Chamber, the Cleansing Collection Chamber and
the tap regularly
Clean with water and then leave the components to drip dry
Clean the tap with a mild hypochlorite solution
If necessary, use a plastic brush to aid cleaning
Remove the Germkill Processor while cleaning and keep upright in a
separate dry place
Empty the water from the Cleansing Collection Chamber before removing the
Microcharged Membrane assembly
Remove the Germkill Processor before emptying out the water from the
Cleansing Collection Chamber
The Pureit guarantee of getting water that is Safer Than Boiled Water
applies only if you ensure that the Transparent Chamber of the purifier and
the tap are hygienically kept, and that germs are not introduced due to
contact with hands, drying with a cloth, wash or any other means
You should only store water in Pureit Advanced purifier and not use other
bottles and containers, to avoid re-contamination of the water
Always use all three components of the Pureit Advanced Germkill Kit
together
You should ensure that the area around and beneath the purifier is kept
clean at all times
Keep all components of the Pureit Advanced Germkill Kit out of reach of
children at all times
DONTs
Do not clean with soap or detergent, or any abrasive cleaners or tools like wire Mesh
Do not twist the Advanced Microfibre Mesh while cleaning. The Advanced
Microfiber Mesh might change its color over a period of time. This does not
affect the performance of the Advanced Microfiber Mesh
Do not use any soap or detergent. Ensure that you dont inadvertently introduce
germs into the Transparent Chamber or the tap e.g. through your hands or by
using a drying cloth. Always use purified Pureit Advanced water for doing the last
rinse of the Transparent Chamber, and then let it drip-dry
Do not normally wash the Cleansing-Collection Chamber
Dont pour boiling or hot water (more than 50C) into, or on the Pureit Advanced
system. Similarly dont pour freezing cold water (less than 10C) into, or on the
Pureit Advanced system
Do not pour hot water directly from an overhead tank or any other source in your
Pureit Advanced as hot water uses up the Germkill Kit faster than normal. If
required, allow the water to cool to room temperature before pouring it in the Top
Chamber. For the same reason do not keep your Pureit Advanced in hot surroundings
like direct sunlight, near a stove or near a fridge
Never buy the Pureit Advanced system, or a Pureit Advanced Germkill Kit from an
unauthorized source. You can visit a store near you to buy a Germkill Kit or call us
at the Pureit helpline, and we will deliver a new Germkill Kit to you at your home
for a minimal delivery charge
Dont in any way try to open the three Pureit Advanced Germkill Kit
components
Never use the system once the Pureit Advanced Germkill Life Indicator shows a
full red colour in the window, with no white colour visible
Dont expose any of the components to fire
29
DOs
Ensure that the purifier is placed on a flat surface at all times, and never
tilt the Transparent Chamber to take out water
If you ever want to shift the purifier, do so only after both the Top Chamber
and Cleansing Collection Chamber are empty. Otherwise the purifier may leak,
and the purification process may get affected
Always rely only on the red Indicator to replace the Germkill Kit. The
Auto Shut-Off is only an additional assurance of safety in some cases,
the input water quality may prevent it from functioning
Freshly purified water should be used for drinking
Output water may continue to have flora which are harmless and pose no
health hazard to normal healthy adults and children
Always clean the Pureit Advanced system only as described in the section
on cleaning
DONTs
Dont drop any of the components, or the purifier as a whole from a height. This
may cause the components to fracture or break, and the guarantee of getting
water Safer Than Boiled Water will no longer be valid
Dont put any chemical fluids in the Pureit Advanced system. This is meant strictly
for drinking water only
If the Transparent Chamber is full, please do not fill water in the Top Chamber,
otherwise water will overflow from the Transparent Chamber
Do not try to open the Germkill Processor
Do not pour water in purifier after Germkill Life Indicator turns fully red.
This will prevent water overflowing due to Auto Shut-Off. This ensures no one
is accidentally hurt by slipping on the water. Also, no household item kept near
purifier would get damaged by leaked water
Do not use the Germkill Kit after expiry which is post two years from the
date of packing
Do not keep the Pureit Advanced purifier in direct sunlight as it may trigger
growth of algae if input water is significantly contaminated
Do not use water not intended for drinking in Pureit Advanced system e.g., from
abandoned or abused water bodies or water sources in which human, animal or
industrial wastes are disposed, or water that is excessively acidic or alkaline
Water stored for more than two days should not be consumed
Do not remove the Batching Chamber from the Cleansing Collection Chamber. If
it gets removed accidentally, then replace the parts in proper location, as was
assembled initially for consistent performance
Do not meddle with the Microcharged Membrane else it will get damaged and you
might get unsafe water
Dont drink water from the purifier if any one of the Germkill Kit components
is not fitted
Do not allow any foreign or unexpected material (like dust, ants, insects, other
pests) to enter into the storage tank. The purified water in the storage tank may
deteriorate in the process.
30
mo[aQ> H$mo Bg H$ma {S>OmBZ {H$m Jm h H$s O~ VH$ Amn CgH$m moJ Bg nwpVH$m Ho$ AZwgma H$a|Jo V~ VH$ Amn H$mo C~bo nmZr go
mXm gwa{jV nmZr {bVm ahoJm & {ZZ{b{IV MrOm| na mZ X| &
m H$a|
Q>mn {bS>, Q>mn Mo~a, bo{OJ H$boeZ Mo~a Ama Q>n {Z{V n go gm$ H$a| &
nmZr go gm$ H$ao Ama {$a nwOm} H$mo AN>r Vah go gyIZo Ho$ {bE N>moS> Xo &
Q>n H$mo hH$m hmBnmobmoamBQ> gmoyeZ go gm$ H$a| &
OaV nS>Zo na g$mB Ho$ {bE EH$ bmpQ>H$ ~e H$m CnmoJ H$a| &
g$mB Ho$ XmamZ O{H$b mogoga H$aU H$mo hQ>m X| Ama EH$ AbJ gyIr OJh na
grYm aI| &
mBH$moMmS> o~oZ Ag|br H$mo hQ>mZo go nhbo boqOJ H$boeZ Mo~a go nmZr {ZH$mb
X| &
boqOJ H$boeZ Mo~a | go nmZr Imbr H$aZo go nhbo, O{H$b mogoga {ZH$mb| &
C~bo nmZr go mXm gwa{jV nmZr {bZo H$s JmaQ>r Ho$db V~ bmJy hmoJr AJa Amn
gw{ZpMV H$aVo h {H$ w[a$ma H$m Q>mgna|Q> M|~a VWm Zb gm$-gwWao aI| JE h,
VWm hmW, H$nS>o go gwImZo, YmoZo m A {H$gr ^r VarHo$ go {H$Q>mUwAm| Ho$ gnH$ |
Z Amm hmo &
AmnH$mo Ho$db mo[aQ> ES>dmgS> w[a$a | hr nmZr gJ{hV H$aZm Mm{hE Ama nmZr H$mo
nwZ X{fV hmoZo go ~MmZo Ho$ {bE A ~moVb Ama ~VZ H$m CnmoJ Zht H$aZm Mm{hE &
mo[aQ> ES>dmgS> O{H$b {H$Q> Ho$ g^r VrZ nwO} EH$gmW BVomb H$a| &
gw{ZpMV H$a| H$s w[a$ma Ho$ BX-{JX H$m jo gm$ h &
mo[aQ> ES>dmgS> O{H$b {H$Q> Ho$ g^r nwO} hoem ~m| {H$ nhM go Xa aI| &
gw{ZpMV H$a| H$s AmnH$m w[a$ma hoem gVb aho, VWm nmZr {ZH$mbZo Ho$ {bE
Q>mgna|Q> Mo~a H$mo Z PwH$mE &
AJa Amn w[a$ma H$mo Xgar OJh aIZm MmhVo h Vmo o gw{ZpMV H$a b| H$s Q>mn
Mo~a VWm boqOJ H$boeZ Mo~a XmoZm| hr Imbr hmo & AWm w[a$ma go [agmd hmo
gH$Vm h, VWm nw[a{$Ho$eZ H$s {H$m ~{YV hmo gH$Vr h &
m Z H$a|
gm~wZ m {S>Q>O}Q> AWdm H$moB AnKfH$ g$mB CnH$aU Ogo Vma H$s Ombr go
gm$ Z H$a| &
g$mB H$aVo dV ES>dmgS> mBH$mo $mB~a oe H$mo Z moS>o & g OmVo
ES>dmgS> mBH$mo$moB~a oe H$m aJ ~Xb gH$Vm h & Bggo ES>dmgS> mBH$mo$mB~a
oe H$m H$mXeZ ^m{dV Zhr hmoVm h &
{H$gr ^r gm~wZ m {S>Q>aOQ> H$m BVomb Z H$a| & gw{ZpMV H$a b| H$s Q>mgna|Q>
Mo~a m Zb o AOmZo | ^r {H$Q>mUw doe Z H$a| CXm- AmnHo$ hmW m gwImZo
dmbo H$nS>o go & Q>mgna|Q> Mo~a H$mo AmIar ~ma YmoZo Ho$ {bE hoem w[a$mBS>
mo[aQ> ES>dmgS> nmZr H$m hr BVomb H$a|, Ama {$a go gyIZo Ho$ {bE aIo &
b|qOJ H$boeZ Mo~a H$mo Am Vma na gm$ Z H$a| &
mo[aQ> ES>dmgS> {gQ> |, m Cg na C~bVm hAm m Ja nmZr
(500C A{YH$ VmnmZ) Z S>mb| & gmW hr mo[aQ> ES>dmgS> {gQ> |, m CgHo$
Cna Om XoZo dmbm R>S>m nmZr (100C H$) Z S>mb| &
AmnHo$ mo[aQ> ES>dmgS> | {H$gr AmodahoS> Q>H$s m A {H$gr moV go grYm Ja
nmZr Z S>mb| mo{H$ Ja nmZr O{H$b {H$Q> H$s InV gmm go A{YH$ J{V
go H$aVm h & AmdH$ hmo Vmo nmZr H$mo Q>mn Mo~a o S>mbZo go nhbo Cgo gmm
VmnmZ VH$ AmZo X| & Bgr H$maU go AmnHo$ mo[aQ> ES>dmgS> H$mo grYo gyaO H$s
amoeZr |, Q>mod Ho$ m {$O Ho$ nmg Z aIo &
H$^r ^r {H$gr AZm{YH$V moV go mo[aQ> ES>dmgS> {gQ>, m moaBQ> O{H$b
{H$Q> Z IarXo & Amn AmnHo$ H$ar~r Q>moa go O{H$b {H$Q> IarX gH$Vo h
m mo[aQ> honbmBZ go gnH$ H$a| Ama h Zmm {Sbrdar ewH$ na EH$ Zm
O{H$b {H$Q> AmnHo$ Ka nhMm X|Jo &
mo[aQ> ES>dmgS> O{H$b {H$Q> Ho$ VrZ nwOm} H$mo {H$gr ^r VarHo$ go ImobZo H$s
H$mo{ee Z H$a| &
mo[aQ> O{H$b ES>dmgS> bmB$ B{S>Ho$Q>a nyar Vah go bmb {XI ahm hmo, Ama
go$X aJ {~Hw$b {XImB Z Xo ahm hmo V~ Bg {gQ> H$m H$VB BVomb Z H$a| &
31
mo[aQ> H$mo Bg H$ma {S>OmBZ {H$m Jm h H$s O~ VH$ Amn CgH$m moJ Bg nwpVH$m Ho$ AZwgma H$a|Jo V~ VH$ Amn H$mo C~bo
nmZr go mXm gwa{jV nmZr {bVm ahoJm & {ZZ{b{IV MrOm| na mZ X| &
m H$a|
O{H$b {H$Q> ~XbZo Ho$ {bE hoem Ho$db bmb BpS>Ho$Q>a na hr ^amogm aI|& AmQ>mo
eQ>-Am$ Ho$db gwajm H$m EH$ A{Var$ ^amogm h - Hw$N> mbm| |, AmZodmbo nmZr
H$s JwUdmm CgHo$ H$m | H$mdQ> bm gH$Vr h &
nrZo Ho$ {bE VmOm ew {H$m Jm nmZr hr CnmoJ H$aZm Mm{hE &
Vma nmZr | bmoam hmo gH$Vo h Omo ZwH$gmZH$mar Zht Ama Omo gmm dm dmbo
dH$m| d ~mbH$m| Ho$ dm Ho$ {bE {H$gr H$ma H$m IVam Zht hmoVo h &
mo[aQ> ES>dmgS> {gQ> H$mo Ho$db g$mB Ho$ goeZ | {H$E JE dUZ Ho$ AZwgma hr
gm$ H$a| &
m Z H$a|
32
FAQs
There is condensation in the Transparent Chamber. Is
this a problem?
33
FAQs
Will Pureit Advanced remove salt and oil?
Input water may contain many materials which affect the taste
of water. Of these, Pureit Advanced removes materials like
oil, sand, soil, clay, dirt, decayed animal and plant waste, and
harmful pesticide impurities and is therefore likely to improve
the taste of water. However, Pureit Advanced does not
remove some dissolved salts that may contribute to taste like
sodium chloride salt, calcium and magnesium.
In fact, Pureit Advanced retains some good dissolved salts
present in drinking water. This may affect the taste of water.
Can one pour brackish water into Pureit Advanced?
Yes, the water will be free of harmful germs, but there may
not always be an improvement in taste. However by pouring
brackish/sea water into the Pureit Advanced, there may
be a risk of choking the system, and the Auto Shut-Off
mechanism may malfunction.
Can there sometimes be particles in the water stored
in the Transparent Chamber?
No. Particles will not escape into the Transparent Chamber
through the filtering media. However you have to drain the
first cycle that gets collected in the Transparent Chamber.
Sometimes there is a chlorine like smell near the
Germkill Processor. Is this a problem?
No, this is not a problem.You will continue to get absolutely
34
Ama mo[aQ> ES>dmgS> Ho$ AXa Om hmo gH$Vo h & h, {H$gr ^r Vah
go mo[aQ> ES>dmgS>> H$s O{H$b jVm H$mo ^m{dV Zht H$aVm h &
Ho$qbJ amoH$Zo Ho$ {bE H$^r H$^r Q>mgna|Q> M~a Ama Q>mn M~a H$s
g$mB H$s{OE& {H$gr ^r AnKfH$ brZa m CnH$aUm| H$m CnmoJ Z
H$a| & {ddaUm| Ho$ {bE mo[aQ> ES>ndmgS> H$s g$mB Ama aI aImd
IS> go gX^ b| &
m mo[aQ> ES>dmgS> jma VWm Vob {ZH$mb nmEoJm?
mo[aQ> ES>dmgS> | S>mbo OmZodmbo nmZr | H$B nXmW hmo gH$Vo h Omo
nmZr Ho$ dmX na Aga S>mbVo h & BZ| go mo[aQ> ES>dmgS> Vob, aoVr,
{>r, Yyb, mUr VWm dZnVrm| H$m gS>m hAm H$Mam, Ama hm{ZH$maH$
35
36
Date of purchase
Purchasers name
Telephone no.
Address
Dealers name
Address
Note:
1. Please retain the bill of purchase.
2. Please quote the serial number, model & date of purchase in all your correspondence.
3. Call Pureit helpline to upate your details into our database.
______________________________
Dealers Signature
(with rubber stamp)
37
General
For the purpose of this warranty, the following expressions shall have the following meanings respectively:
The purifier shall mean the purifier described in the invoice.
The customer shall mean the purchaser of the purifier from the company or the companys authorised dealer who is a party to the invoice.
The company shall mean Hindustan Unilever Limited.
Invoice shall mean the Invoice issued for the purifier by the retailer to the customer describing the purifier and indicating, inter alia, the total purchase price thereof,
the name and address of the customer.
User manual shall mean the instructions for installation, use and maintenance contained in the leaflet published by the company, and delivered to the Customer at the time of sale of the
purifier.
38
39
61 cms / 61 g|.
Width / MmS>mB
33 cms / 33 g|.
Depth / JhamB
Weight / dOZ
r
r
36 cms / 36 g|. r
3.7 kgs / 3.7 {H$ Jm
Material of construction
{ZmU gmJr
mo[a{$Ho$eZ jVm
Expiry period / OrdZ Ad{Y
Germkill performance standard
gmJr Food safe, non-toxic, engineering plastics / Im JoS>, Ja {dfbo A{^m{H$s bmpQ>H$
The Germkill Kit has been designed to typically give 1500 litres (under standard
test conditions^) of Safer Than Boiled Water ~ / O{H$b {H$Q> H$mo bJ^J 1500 brQ>a
(moJembo narjU pW{V^ Ho$ AVJV) C~bo nmZr go mXm gwa{jV nmZr~ XoZo Ho$ {bE ~Zmm Jm
Two years from the date of manufacturing / {ZmU {V{W go Xmo df
Meets stringent international criteria of the Environmental Protection Agency (EPA),
USA, for harmful viruses & bacteria removal
EZdma|Q>b moQ>oeZ EO|gr (B nr E). y Eg Eo. hm{ZH$maH$ ~Q>o[am Ama dmBagm| {ZybZ Ho$ H$S>o
mn XS>m| na Iam CVaVm h
^Standard test conditions /
go 65%
As per Independent Lab Tests Pureit removes lead from input water whereas boiling cannot.
h.
40
Microfibre Mesh
Germkill Kit
Germkill Action
Germkill Processor
Polisher
HUL 2010
fic
i
Ce
rt
Central
Food
Technological
Research
Institute
National
Environmental
Engineering
Research
Institute
Indian Public
Health
Association
o ns
ati
Institution of
Public Health
Engineers,
India
Apollo
Hospitals,
Chennai
Setting benchmarks
in water purification
Winning laurels
across the world
- India
- Mexico
- Indonesia
- Brazil
- Bangladesh
No.1 choice of
families Worldwide
*Representation of the US EPA torture test of 4 log virus removed from 1 ml of contaminated water.
#
Based on Unit shipment sales for 2013. Excludes pitchers and faucet mount systems sales and includes only in-home point-of-use drinking water treatment systems.
~
As per Independent Lab Tests Pureit removes lead from input water whereas boiling cannot.