Simulation of a multiple-effect evaporator

Instructions
1. a. On the Tools menu, click Options, then click the Calculation tab and tick on the Iteration

2. For a forward feed 2-effect evaporator


In the spreadsheet "2-Effect"
a. Insert parameter values in the yellow cells
b. Turn the "SWITCH" ON (set the value in the cell B9 (red cell) equal to 1)
c. Iterate (by pressing F9) until "FINISH" or "ALARM" signal is shown in the control panel
d. If a signal to "REDUCE Ts or mwin" is shown in the control panel, turn the SWITCH OFF, reduce the
in cells B28 or B29 respectively and start again from 2b
e. If a signal to "INCREASE Ts or mwin" is shown in the control panel, turn the SWITCH OFF, increase
in cells B28 or B29 respectively and start again from 2b
f. When "FINISH" is shown in the control panel, read the results in the green cells (B34-B38)
g. If a solution can not be reached under any combination of T s and mwin values, change the heat tran
and repeat steps 2a to 2f
h. To recalculate for different parameter values turn the "SWITCH" OFF (set the value in the cell B9 e

3. For a forward-feed 4-effect evaporator


In the spreadsheet "4-Effect Forward"
a. Insert parameter values in the yellow cells
b. Turn the "SWITCH" ON (set the value in the cell B9 (red cell) equal to 1)
c. Iterate (by pressing F9) until "FINISH" or "ALARM" signal is shown in the control panel
d. If a signal to "REDUCE Ts or mwin" is shown in the control panel, turn the SWITCH OFF, reduce the
in the cells B28 or B29 respectively and start again from 2b
e. If a signal to "INCREASE Ts or mwin" is shown in the control panel, turn the SWITCH OFF, increase
in the cells B28 or B29 respectively and start again from 2b
f. When "FINISH" is shown in the control panel, read the results in the green cells (B33-B37)
g. If a solution can not be reached under any combination of T s and mwin values, change the heat tran
and/or Q19 and repeat steps 2a to 2f
h. To recalculate for different parameter values turn the "SWITCH" OFF (set the value in the cell B9 e
4. For a backward-feed 4-effect evaporator
In the spreadsheet "4-Effect Backward"
a. Insert parameter values in the yellow cells
b. Turn the "SWITCH" ON (set the value in the cell B9 (red cell) equal to 1)
c. Iterate (by pressing F9) until "FINISH" or "ALARM" signal is shown in the control panel

d. If a signal to "REDUCE Ts or mwin" is shown in the control panel, turn the SWITCH OFF, reduce the
in the cells B28 or B29 respectively and start again from 2b
e. If a signal to "INCREASE Ts or mwin" is shown in the control panel, turn the SWITCH OFF, increase
in the cells B28 or B29 respectively and start again from 2b
f. When "FINISH" is shown in the control panel, read the results in the green cells (B33-B37)
g. If a solution can not be reached under any combination of T s and mwin values, change the heat tran
and/or Q19 and repeat steps 2a to 2f
h. To recalculate for different parameter values turn the "SWITCH" OFF (set the value in the cell B9 e

the Iteration box. On Maximum iterations box write 1000

TCH OFF, reduce the value of either T s or mwin

WITCH OFF, increase the value of either T s or mwin

ls (B34-B38)
change the heat transfer area in the cells H19 and/or J19 and/or M19

value in the cell B9 equal to 0) and repeat steps 2a to 2f

TCH OFF, reduce the value of either T s or mwin

WITCH OFF, increase the value of either T s or mwin

ls (B33-B37)
change the heat transfer area in the cells H19 and/or J19 and/or L19 and/or N19

value in the cell B9 equal to 0) and repeat steps 2a to 2f

TCH OFF, reduce the value of either T s or mwin

WITCH OFF, increase the value of either T s or mwin

ls (B33-B37)
change the heat transfer area in the cells H19 and/or J19 and/or L19 and/or N19

value in the cell B9 equal to 0) and repeat steps 2a to 2f

The following assumptions are used


1) The pressure drop in the vapour lines is neglected
2) The effect of superheating on the vapour enthalpy due to the BPE is neglected
3) The heat losses to the environment are taken into account. If cells B23 or B24 for Ulos and Ao
4) The condensate from each effect exits at the condensation temperature
5) The condenser is assumed to be a surface condenser

The following empirical relationships are used in the calculations


a) Heat capacity of liquid foods (equation of Dickerson), J/kg oC

c p =1672+2508 x w
where xw is the mass fraction of water content
b) Boiling Point Elevation, oC
2

BPE =2 .7 x s 8 . 8 x s +21 . 2 x s

where xs is the mass fraction of solids content


c) Heat capacity of liquid water, J/kgoC

c p =42111 . 34 T +0 . 015T

where T is temperature in oC
d) Enthalpy of saturated steam and vapour, kJ/kg

H v =2501+1 . 919T 0 . 0017T 2


where T is temperature in oC
e) Latent heat of vaporization of water, kJ/kg

=25012. 265 T 0 . 0018 T

where T is temperature in oC
f) Vapour pressure of liquid water, atm (Ref. 15)

8. 29692

log p w =10 .79586 ( 1 )+5 .02808 log +1 . 50474 x 104 110

273 .16
T

[( ) ])+ 0. 42873 x 10
1

where

273 .16
T

with T in Kelvin

Ulos and Ao L are set equal to 0, the heat losses are neglected

)1 ])

+ 0. 42873 x 103 ( 104 . 76955 ( 1 )1 )2 . 2195983

Forward-Feed 2-Effect Evaporator

Control panel

SWITCH=

FINISHED
0.000

Input data
Feed flow rate,
Feed solids content,
Desired product solids content,
Feed temperature,
Temperature of the environment,
Overall Heat transfer coeffic. for heat losses,

mf =
xf =
Xspec =

10000 kg/h
10%
30%

Tf =

70 oC

Te =

20 oC

Ulos=

0 W/m2oC

Outside Area of each effect of the evaporator, AoL=

50 m2

Cooling water temper. at the inlet of the cond., Twin=

25 oC

Control variables
Steam temperature,

Ts =

Mass flow rate of cooling water in the conden.,mWin =

122 oC
38300 kg/h

Results
Concentrated product flow rate,
Solids content at the outlet,
Steam consumption,
Steam economy
Cooling water flow rate,

m p=
x p=
m s=
m Win=

3332 kg/h
30.0%
3937 kg/h
1.7 kg/kg
38300 kg/h

Parameters

1st EFFECT 2nd EFFECT

Heat transfer area (m2),

CONDENSER

80

80

1800

1000

Overal heat transf. coef.

Liquid flow rate at the inlet (kg/s),

mi

2.778

1.878

Cooling water flow rate in

Solids content at the inlet,

xi

0.1

0.148

Cooling water temper. in

Ti

70

105.3

Water vapour temper. in

Boiling temperature (oC),

Tb

105.3

79.8

Cooling water temp. out

Saturation temperature ( C),

Tv

Saturation pressure (atm),

105.0
1.194

79.2
0.453

Condensation temperat.
Water vapour pressure

16.7

25.2

BPE

0.3

0.6

Heat capacity of liquid at inlet (J/kg C), cpi

3929

3809

Heat capacity of liquid at outlet(J/kgoC), cpo

3809

3427

Overall heat transfer coef. (W/m2oC),

Liquid temperature at the inlet ( C),


o

Temperature drop (oC),


Boiling Point Elevation (oC),
o

Heat losses (W),

qL

Evaporation rate (kg/s),

mv

0.899

0.953

1.878

0.925

0.148

0.300

Heating steam/vapour flow rate (kg /s), m s

1.094

0.899

Heating steam/vapour temperature ( C), Ts

122

105.0

Liquid flow rate at the outlet (kg/s),

mo

Solids content at the outlet,

xo
o

Heat transf. area

CONDENSER
50 m2
2500 W/m2oC
10.639 kg/s
25 oC
79.2 oC
74.5 oC
79.1 oC
0.452 atm

Forward-Feed 4-Effect Evaporator

Control panel

SWITCH=

FINISHED
0.0000

Input data
Feed flow rate,
Feed solids content,
Desired product solids content,
Feed temperature,
Temperature of the environment,
Overall Heat transfer coeffic. for heat losses,

mf =
xf =
Xspec =

20000 kg/h
9%
48%

Tf =

60 oC

Te =

20 oC

Ulos=

0 W/m2oC

Outside Area of each effect of the evaporator, AoL=

50 m2

Cooling water temper. at the inlet of the cond., Twin=

25 oC

Control variables
Steam temperature,

Ts =

Mass flow rate of cooling water in the conden.,mWin =

75 oC
530000 kg/h

Results
Concentrated product flow rate,
Solids content at the outlet,
Steam consumption,
Steam economy
Cooling water flow rate,

m p=
x p=
m s=
m Win=

3756 kg/h
47.9%
4244 kg/h
3.8 kg/kg
530000 kg/h

1st EFFECT
Heat transfer area (m2),

2nd EFFECT

3rd EFFECT

4th EFFECT

270

270

270

270

2200

1800

1300

506

Liquid flow rate at the inlet (kg/s),

mi

5.556

4.481

3.372

2.230

Solids content at the inlet,

xi

0.09

0.112

0.148

0.224

Ti

60

70.4

65.0

57.3

Boiling temperature (oC),

Tb

70.4

65.0

57.3

37.1

Saturation temperature ( C),

Tv

Saturation pressure (atm),

70.2
0.310

64.7
0.244

56.9
0.170

35.7
0.058

4.6

5.2

7.4

19.8

BPE

0.2

0.3

0.4

1.6

Heat capacity of liquid at inlet (J/kg C), cpi

3954

3900

3808

3618

Heat capacity of liquid at outlet(J/kgoC), cpo

3900

3808

3618

2979

1.075

1.109

1.142

1.188

4.481

3.372

2.230

1.042

0.112

0.148

0.224

0.479

Heating steam/vapour flow rate (kg /s), m s

1.179

1.075

1.109

1.142

Heating steam/vapour temperature ( C), Ts

75

70.2

64.7

56.9

Overall heat transfer coef. (W/m C),


2o

Liquid temperature at the inlet ( C),


o

Temperature drop (oC),


Boiling Point Elevation (oC),
o

Heat losses (W),

qL

Evaporation rate (kg/s),

mv

Liquid flow rate at the outlet (kg/s),

mo

Solids content at the outlet,

xo
o

CONDENSER
Heat transf. area

150 m2

Overal heat transf. coef.

2500 W/m2oC

Cooling water flow rate in

147.2 kg/s

Cooling water temper. in

25 oC

Water vapour temper. in

35.7 oC

Cooling water temp. out

29.7 oC

Condensation temperat.
Water vapour pressure

35.7 oC
0.058 atm

Backward-Feed 4-Effect Evaporator

Control panel

SWITCH=

FINISHED
0.000

Input data
Feed flow rate,
Feed solids content,
Desired product solids content,
Feed temperature,
Temperature of the environment,
Overall Heat transfer coeffic. for heat losses,

mf =
xf =
Xspec =

20000 kg/h
9%
48%

Tf =

60 oC

Te =

20 oC

Ulos=

0 W/m2oC

Outside Area of each effect of the evaporator, AoL=

50 m2

Cooling water temper. at the inlet of the cond., Twin=

25 oC

Control variables
Steam temperature,

Ts =

Mass flow rate of cooling water in the conden.,mWin =

75 oC
220000 kg/h

Results
Concentrated product flow rate,
Solids content at the outlet,
Steam consumption,
Steam economy
Cooling water flow rate,

m p=
x p=
m s=
m Win=

3745 kg/h
48.1%
4327 kg/h
3.8 kg/kg
220000 kg/h

1st EFFECT
Heat transfer area (m2),

2nd EFFECT

3rd EFFECT

4th EFFECT

270

270

270

270

1214

1400

1270

1044

Liquid flow rate at the inlet (kg/s),

mi

2.202

3.312

4.350

5.556

Solids content at the inlet,

xi

0.227

0.151

0.115

0.090

Ti

57.7

49.6

40.5

60.0

Boiling temperature (oC),

Tb

66.5

57.7

49.6

40.5

Saturation temperature ( C),

Tv

Saturation pressure (atm),

64.9
0.246

57.2
0.173

49.3
0.118

40.3
0.074

8.5

7.2

7.7

8.8

BPE

1.6

0.4

0.3

0.2

Heat capacity of liquid at inlet (J/kg C), cpi

3611

3801

3892

3954

Heat capacity of liquid at outlet(J/kgoC), cpo

2974

3611

3801

3892

1.162

1.110

1.037

1.206

1.040

2.202

3.312

4.350

0.481

0.227

0.151

0.115

Heating steam/vapour flow rate (kg /s), m s

1.202

1.162

1.110

1.037

Heating steam/vapour temperature ( C), Ts

75

64.9

57.2

49.3

Overall heat transfer coef. (W/m C),


2o

Liquid temperature at the inlet ( C),


o

Temperature drop (oC),


Boiling Point Elevation (oC),
o

Heat losses (W),

qL

Evaporation rate (kg/s),

mv

Liquid flow rate at the outlet (kg/s),

mo

Solids content at the outlet,

xo
o

CONDENSER
Heat transf. area

150 m2

Overal heat transf. coef.

2500 W/m2oC

Cooling water flow rate in

61.1 kg/s

Cooling water temper. in

25 oC

Water vapour temper. in

40.3 oC

Cooling water temp. out

36.4 oC

Condensation temperat.
Water vapour pressure

40.2 oC
0.074 atm