Professional Documents
Culture Documents
Copyright
2007 Alcatel-Lucent. All rights reserved.
Specifications in this manual are subject to change without notice.
Originated in the USA.
Trademarks
AOS-W, Alcatel 4308, Alcatel 4324, Alcatel 6000, Alcatel 41, Alcatel 60/61/65, Alcatel 70, and Alcatel 80 are trademarks of AlcatelLucent in the United States and certain other countries.
Any other trademarks appearing in this manual are the property of their respective companies.
Legal Notice
The use of Alcatel-Lucent switching platforms and software, by all individuals or corporations, to terminate Cisco or Nortel VPN client
devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies, in full, AlcatelLucent from any and all legal actions that might be taken against it with respect to infringement of copyright on behalf of Cisco Systems
or Nortel Networks."
www.alcatel-lucent.com
26801 West Agoura Road
Calabasas, CA 91301
Contents
Preface
Chapter 1
Chapter 2
Appendix A
Guide Overview
Related Documents
Contacting Alcatel-Lucent
Hardware Overview
Package Checklist
8
9
9
9
10
11
11
11
Installation
13
Installation
Pre-Installation Requirements
Physical Installation
Rack Mounting
Tabletop Deployment
Initial Setup and Network Connectivity
13
13
13
13
15
15
Removal
15
17
Physical Specifications
Power Management Specifications
Power Consumption
Power Specifications (AC Input Requirements)
Operating Specifications
Storage Specifications
17
17
17
17
17
18
18
18
18
18
19
19
Contents | 3
4 | Contents
Preface
Guide Overview
z
Chapter 1, Hardware Overview on page 7 provides a detailed hardware overview of the three
OmniAccess WLAN Switches covered in this guide: the OAW-4504, the OAW-4604, and the OAW4704.
Related Documents
The following documents are referred to in this guide and are considered components of the complete
documentation set needed for successful installation and management of an OmniAccess WLAN
Switch:
z
Contacting Alcatel-Lucent
Web Site Support
Main Site
http://www.alcatel-lucent.com/wps/portal/enterprise
Support Site
https://service.esd.alcatel-lucent.com
Support Email
support@ind.alcatel.com
Telephone Support
North America
1-800-995-2696
Latin America
1-877-919-9526
Europe
Asia Pacific
Worldwide
1-818-878-4507
Preface | 5
6 | Preface
Chapter 1
Hardware Overview
OAW-4504-8: includes built-in campus connected AP support of up to 8 APs; additional AlcatelLucent AP upgrade licenses available.
OAW-4604-32: includes built-in campus connected AP support of up to 32 APs; additional AlcatelLucent AP upgrade licenses available.
NOTE
OAW-4704-64: includes built-in campus connected AP support of up to 64 APs; additional AlcatelLucent AP upgrade licenses available.
Feature related AP licenses are counted independently and in addition to the Alcatel-Lucent AP
upgrade licenses. Contact your Alcatel-Lucent sales representative for complete details regarding
software licensing options and support capacity.
Hardware Overview | 7
The master switch, its redundant master switch, and all of its local switches must run on the same
code of AOS-W. Once you upgrade your network and install an OmniAccess 4504, 4604, or 4704
WLAN Switch into your network, verify that the software version on your switch matches the rest of
the network. If the code shipped on the switch is prior to the version that you upgraded your
network to, you must upgrade the code on the switch to match the rest of the network.
NOTE
Package Checklist
z
NOTE
Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the
carton, including the original packing materials. Use these materials to repack and return the unit to
the supplier if needed.
NOTE
Optional accessories, such as SFP modules, are available for use with an OmniAccess 4504, 4604,
or 4704 and are sold separately. Contact your Alcatel-Lucent sales representative for details and
assistance.
NOTE
8 | Hardware Overview
The physical hardware overview covers all three switches: the OmniAccess 4504, 4604, and 4704 .
The difference between the three switch models is dependent on the licensing level purchased,
which is covered in About the OmniAccess 4504, 4604, and 4704 on page 7. The switch model
depicted in the illustrations throughout this section is the OAW-4504.
Front View
Figure 1 OmniAccess 4504, 4604, and 4704 Front View
Dual-media ports (4x); 1000Base-X
or 10/100/1000Base-T
1000Base-X (SFP)
Ports
NOTE
10/100/1000-Base-T
Gigabit Ethernet Port
Ports zero through three are dual-media ports and can utilize either the 1000Base-X or 10/100/
1000Base-T connections provided. However, the 1000Base-X fiber connection has priority over the
10/100/1000Base-T copper connection. If a link is detected for the 1000Base-X interface, the 10/
100/1000Base-T connection will be disabled.
NOTE
Alcatel-Lucent tests and supports Alcatel-Lucent optics within their switch systems. Third party
optics are not tested or supported; therefore, Alcatel-Lucent does not guarantee proper functionality
of third party optics when used in an Alcatel-Lucent system.
Hardware Overview | 9
RJ-45 Female
Pin-Out
1
2
3
4
5
6
7
8
Signal Name
Function
BI_DA+
BI_DABI_DB+
BI_DC+
BI_DCBI_DBBI_DD+
BI_DD-
Bi-directional pair +A
Bi-directional pair -A
Bi-directional pair +B
Bi-directional pair +C
Bi-directional pair -C
Bi-directional pair -B
Bi-directional pair +D
Bi-directional pair -D
RJ-45 Female
Pin-Out
1
2
3
4
5
6
7
8
Direction
Input
Output
TxD
GND
GND
RxD
Communication settings for the serial console port are indicated in Table 1.
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
9600
None
None
Do not connect an Access Point (AP) to the serial console port. The serial console port is compatible
with only RS-232 devices. Non-RS-232 devices, such as APs, are not supported.
CAUTION
10 | Hardware Overview
Internal
Connections
RJ-45
TxD
3
4
5
GND
RxD
6
DB-9 Male
Pin-Out
DB-9
2
5
3
9
8
7
6
5
4
3
2
1
Ground
RxD
TxD
Direction
Input
Output
Rear View
Figure 5 OmniAccess 4504, 4604, and 4704 Rear View
AC Power Socket
AC Power Socket
The OmniAccess 4504, 4604, and 4704 support integrated AC powering and the AC power socket on the
rear of the unit is for use with an AC power cord (country-specific). Refer to Power Management
Specifications on page 17 for power specification details.
Function
Indicator
Status
POWER
On (Solid Green)
Power on
Off
No power
STATUS
LNK
1000Base-X Ports
ACT
1000Base-X ports
LNK/ACT
10/100/1000Base-T Ports
Link/Activity Status
Indicator
Device is operational
On (Solid Red)
Device failed
On (Solid Amber)
Device is loading
software
Off
No power
On (Solid Green)
Off
No link on port
On (Blinking Green)
Port is transmitting or
receiving data
Off
No activity
On (Solid Green)
On (Blinking Green)
Port is transmitting or
receiving data
Hardware Overview | 11
1000
10/100/1000Base-T Ports
12 | Hardware Overview
Function
Interface Speed
Indicator
Indicator
Status
Off
No link on port
On (Solid Green)
Off
10/100 Mbps
interface speed in use
Chapter 2
Installation
Installation
Pre-Installation Requirements
The following tools and equipment are required for installation of an OmniAccess 4504, 4604, or 4704:
z
6-32 x 1/4 Phillips Flat Head Screws (6x, included with rack mount brackets)
12-24 x 5/8 Phillips Flat Head Screws (4x, 19-inch (48.26 cm) rack system mount screws)
Physical Installation
Rack Mounting
To install an OmniAccess 4504, 4604, or 4704 switch into a 19-inch (48.26 cm) rack system:
1. Place a rack mount bracket over the mounting holes on one side of the switch (see Figure 1).
2. Secure the bracket to the switch using three 6-32 x 1/4 phillips flat head screws and a suitable
screwdriver (see Figure 1).
3. Repeat these steps on the opposite side of the switch.
Figure 1 Rack Mount Brackets
Switch
Installation | 13
4. Mount the switch within your organizations rack system using four 12-24 x 5/8 phillips flat head
screws and a suitable screwdriver (see Figure 2).
Figure 2 Rack Mount Installation
Standard 19-inch
Rack System
12-24 x 5/8
Phillips Flat Head Screws
(4x, 2x per bracket)
5. Leave a minimum of four inches (10 cm) of space on the left and right side of the unit for proper air
flow and ventilation (see Figure 3).
6. Leave additional space in the front and back of the unit to access power cords, network cables, and
LED status indicators (see Figure 3).
Figure 3 Air Flow Requirements
NOTE
14 | Installation
OmniAccess 4504, 4604, and 4704 switches do not have a switch for turning power to the unit on or
off. Power to the unit is controlled by connecting or disconnecting the plug on the power cord to or
from an electrical outlet.
Tabletop Deployment
To deploy an OmniAccess 4504, 4604, or 4704 switch on a flat surface, such as a tabletop:
1. Insert the four, rubber mounting feet into the bottom of the unit and place the unit on a flat, hard
surface.
Removal
To remove an OmniAccess 4504, 4604, or 4704 switch from a 19-inch (48.26 cm) rack system:
1. Disconnect power to the switch by unplugging the power cord from the electrical outlet.
2. Loosen and remove the four rack system mount screws securing the switch to your organizations
rack system.
3. Remove the switch from the rack system.
Installation | 15
16 | Installation
Appendix A
Specifications, Safety &
Compliance
Specifications
Physical Specifications
z
Shipping Weight:
OAW-4504: 35 W maximum
OAW-4604: 45 W maximum
OAW-4704: 60 W maximum
OAW-4504:
OAW-4604/OAW-4704:
Operating Specifications
z
Storage Specifications
z
CLASS 1
LASER PRODUCT
Use of controls or adjustments of performance or procedures other than those specified in this
manual may result in hazardous radiation exposure.
CAUTION
This product complies with 21 CFR Chapter 1, Subchapter J, Part 1040.10, and IEC 60825-1: 1993,
A1: 1997, A2: 2001, IEC 60825-2: 2000.
For continued compliance with the above laser safety standards, only approved Class 1 modules from
our approved vendors should be installed in Alcatel-Lucent products.
China RoHS
Alcatel-Lucent products also comply with China environmental declaration requirements
and are labeled with the EFUP e label shown at the left.