AUTOMATIC METER READING FOR


ELECTRICITY USING POWER LINE
COMMUNICATION
Poonam Borle, Ankita Saswadkar, Deepali Hiwarkar, Rupali S. Kad
Dept. of E&TC, Pimpri Chinchwad College of Engineering, Pune, Maharashtra, India
Abstract: As in every where automation is required to reduce the work so we decided to implement to automatic meter
reading using power line communication. AMR is the modern Power measuring device .It is being used in measuring
electricity , gas , water consumption in many countries on the world since it has a lot of advantages that the old analog
meters doesnt have. It has advantages in safety , real time measuring and time saving as well as it has a better user
interface and digital data analysis .Data is send over existing carrier thats reduces the complexity and cost of system.
Keywords: AMR, PLC, PLCC.
I. INTRODUCTION
Power is the soul of world which is related to the electricity and electricity is the word which now rules the
world. So, proper utilization of this commodity is of immense important to us. Hence, it is necessary to measure power
consumption. Normally, large scale industries consist of various departments like production, storage, package,
administration, transportation situated away from each other. For such industries, it is necessary to maintain record of
daily power consumed by every department to keep check on excess power consumed.
A power line carrier (PLC) communication system operating on a conventional three wire (Hot (H), Neutral
(N) and Ground (G) wires) power line uses more than one of the several RF transmission lines that are defined by the
three wire power line to improve communication between units of the PLC system. According to a first embodiment a
PLC system transmitter sends out of phase RF signals across the H and G wires and across the N and G power wires to
the PLC system receiver, which receives and combines both of the out of phase transmissions, and so even if one of
these paths is severely attenuated, the other path can deliver a sufficiently strong RF signal to the receiver for effective
communications. According to another embodiment three different pairs of the H, N and G wires of the power line are
selected in sequence for transmission of the PLC system RF and the pair that results in the best communication
between a system transmitter and receiver is used for continuing communication. Also included is a PLC telephone
extension system for which there is full duplex communication between each of the extension telephones of the system
at different locations in the premises and the premises telephone line.
II. LITERATURE SURVEY
AMR (Automatic Meter Reading ) is the modern Power measuring device .it is being used in measuring
electricity , gas , water consumption in many countries on the world since it has a lot of advantages that the old analog
meters doesnt have .
It has advantages in safety , real time measuring and time save as well as it has a better user interface and
digital data analysis .
AMR appears in several types depends on measured data type and data transfer technologies . We can say that
AMR is the best solution to measure , collect and analyze data for the Mega networks like the electricity transmission
and distribution network in Egypt .
In 1886 , the first ac transmission line was installed . Since this age , it was very important to measure the
energy that consumers pay for . Hence , the first generation of power meters was found which we know as (Watt-Hour
meter ) [1].
As most of us know , the first generation(traditional meter reading devices ) is being used tell now in many
places .It has a lot of disadvantages that we will mention later .
To overcome this disadvantages we have to modify a new reading system that provides remote reading , safety ,
on-time readings and a simple user interface . That is what AMR provides successfully .
The first AMR system was created on 1974 on USA by Mr. Paraskevakos who used a technology developed on
1972 by Theodore George.
Copyright to IJAREEIE

www.ijareeie.com

982

ISSN (Print) : 2320 3765


ISSN (Online): 2278 8875

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering


Vol. 2, Issue 3, March 2013

III. BLOCK DIAGRAM

Fig 1:- Block Diagram


Block Diagram Explanation
1. Power supply:
In the circuit using IC 7805, we can get +5V DC supply.
In the circuit, +5V DC supply is required for :
AVR ATMEGA16
LCD Display
Zero crossing detector
Power line communication IC TDA5051
2. AVR ATMEGA16:
The AVR is the heart of the system. It controls the LCD display, generates interrupts, and controls the power line
communication unit.
3. Energy meter:
An electronic device that measures the amount of electrical energy supplied to a residence or business. It is
electrically fed and composed of electronic controllers. It incorporates an interface which allows data to be transmitted
from the remote terminal to the isolator block.
4. LCD Display:
LCD means Liquid Crystal Display. It is a display device which displays the information provided to it. Its
shape and size varies from application to application.

Copyright to IJAREEIE

www.ijareeie.com

983

ISSN (Print) : 2320 3765


ISSN (Online): 2278 8875

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering


Vol. 2, Issue 3, March 2013

LCD used in our project is 16 X 2 display in which 16 implies no. of characters and 2 implies no. of rows. It also
provides wide range of display functions. It also provides low power consumption. It displays the number of units of
energy transmitted .
5.Optocoupler IC MCT2E:
In our project, we need to provide electrical isolation between them. This isolation is provided by the signal
conditioner circuit which is actually MCT2E.
6. Power line communication IC TDA5051:
The communication between transmitter unit and receiver unit is done through the AC power line. For this
power line communication equipment is implemented which works as a modem. This modem IC, TDA 5051 supports
ASK transmission.
7. Computer:
The final reading is display on computer and total cost of meter reading is display on computer by using serial
communication. The output is display on PC using Visual Basics 6.0 version.

IV. OVERVIEW OF OUR PROJECT


FLOW CHART FOR ENERGY METER:

Copyright to IJAREEIE

www.ijareeie.com

984

ISSN (Print) : 2320 3765


ISSN (Online): 2278 8875

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering


Vol. 2, Issue 3, March 2013

FLOWCHART FOR BASE STATION

SIMULATION RESULTS:

Fig 2: simulation of optocoupler

Fig 3:interfacing of ATMEGA 16 with lcd diaplay


Copyright to IJAREEIE

www.ijareeie.com

985

ISSN (Print) : 2320 3765


ISSN (Online): 2278 8875

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering


Vol. 2, Issue 3, March 2013

Fig 4: interfacing of lcd and ATMEGA 16 and serial communication using virtual terminal
VI. FUTURE SCOPE AND CONCLUSION

The present system is used for meter reading for electricity using power line communication. The system can
be further modified to detect power theft between pole and individual subscribers by installing the units at
each subscriber end.
For the readings of Electricity, Water, Gas or any other meters in the customer premises to be transmitted to a
central base station for further processing, billing etc. With tensof millions of meters to be read periodically
and regularly, this alone represents an enormous market.
The cost of one system is on higher side but if more number of systems are produced, then cost of mass
production will get reduced.
The present system is implemented to send non voice data only. The system can be further developed to
transfer voice data through power line. But the system should be robust enough to handle interference in the
power line.
Distribution Automation, and Supervisory Control and Distribution Automation (DA and SCADA)
This is for the utility companies themselves to monitor and control the Power Distribution Process.
Rural Communication Applications - Where user densities are low and distances are large which makes
installation of fresh infrastructure expensive and also non-profitable.
Generation
of
MIS
reports,
billing,
and
usage
profiling
Ability to disconnect service from remote in case of emergencies or non-payments Efficient resource
(Gas/Water/Energy) monitoring.
Power line communication is a competitive solution to transmit information. It presents an interesting and
economical solution for automatic meter reading. Communication over a power line can reach anywhere there
is an ac outlet. It is popular due to cost effectiveness and availability.
REFERENCES
[1] Chunjuan WEI _ ,Junjie YANG Implementation of Automatic Meter Reading System Using PLC and GPRS Journal of Information
&Computational Science 8:16 (2011)4343 4350
[2] Ahmed Husein, and Mohamed El-Geziry Practical Issues of Power Line Communication for Automatic Meter Reading
SystemsProceedings of the 14 th International Middle East Power Systems Conference (MEPCON10), Cairo University, Egypt,
December 19-21, 2010,
[3] Tarek Khalifa,Kshirasagar Naik and Amiya Nayak "A Survey of Communication Protocols for Automatic Meter Reading
Applications,"IEEE communications sureveys &tutorial ,2011,13 (2):168 182.
[4]Automatic meter reading manual.
[5]Power line communication manual.
[6]http://en.wikipedia.org/wiki/Automatic_meter_reading
[7]http://en.wikipedia.org/wiki/Electric_power_transmission

Copyright to IJAREEIE

www.ijareeie.com

986

ISSN (Print) : 2320 3765


ISSN (Online): 2278 8875

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering


Vol. 2, Issue 3, March 2013

BIOGRAPHY
.

.
Poonam Borle, She is pursuing her B.E. Degree in Electronics & Telecommunication
Engineering in Pimpri Chinchwad College of Engineering, Pune, India.

Deepali Hiwarkar, She is pursuing her B.E. Degree in Electronics &


Telecommunication Engineering in Pimpri Chinchwad College of Engineering,
Pune, India.

Ankita Saswadkar, She is pursuing her B.E. Degree in Electronics &


Telecommunication Engineering in Pimpri Chinchwad College of Engineering,
Pune.

Mrs. R.S.Kad received B.E. degree in Instrumentation and control from Cummins
college of engineering pune and pursuing her MTech (biomedical and
instrumentation) from COEP. Her area of interest is process automation and
electronic instrumentation.

Copyright to IJAREEIE

www.ijareeie.com

987

You might also like