You are on page 1of 3

A

2009-04-07

1st Issue

HrM

REV

DATE

DESCRIPTION

SIGN

CCI Valve Technology AB

PREPARED BY

DATE

HrM

2009-04-07

CHECKED BY

DATE

LgM

2009-04-20

TITLE:

Technical Specification for


Tag nr: LP-SCV / LP-DT
DOCUMENT NUMBER: V299356.60.80

Technical Specification.
Steam conditioning valve equipment.
Date / Rev. / User Id :
Customer :
Project :
PO. No.
Reference No.
Tag No.
No. of valves

2009-04-07 / A / Hillenaar, Maarten


Descon Engineering FZE
Bhikki CCPP
0002528
299356
LP-SCV / LP-DT
1

Operating data
Steam Inlet
Q1
p
t
h
v
K
Steam Outlet
Q2
p
t
h
v
Part free water
Condenser
p
t
h
v
Water Inlet
Qw
p
t
h
v

V299356.60.80

GT1 Startup

GT1+GT2 Nor

GT1+GT2 Max

[kg/h]
[bar a]
[C]
[kJ/kg]
[m/kg]
[-]

18000.0
2.55
274.6
3019.2
0.98405
1.302

26000.0
4.92
269.9
3002.7
0.50186
1.300

36000.0
5.87
275.0
3010.5
0.42361
1.299

[kg/h]
[bar a]
[C]
[kJ/kg]
[m/kg]
[1-x]

20704.2
1.24
105.7
2684.9
1.38571
0.014

29731.3
1.80
117.0
2701.6
0.97605
0.021

41280.8
2.53
127.8
2716.9
0.71045
0.027

[bar a]
[C]
[kJ/kg]
[m/kg]

0.080
80.00
2649.8
20.34100

0.080
80.00
2649.8
20.34100

0.080
80.00
2649.8
20.34100

[kg/h]
[bar a]
[C]
[kJ/kg]
[m/kg]

2704.2
30.00
45.0
191.0
0.00101

3731.3
30.00
45.0
191.0
0.00101

5280.8
30.00
45.0
191.0
0.00101

GT1 Startup

GT1+GT2 Nor

GT1+GT2 Max

Calculated data
Steam Valve
Kv calc
Inlet pipe
Diam ID/OD/t
Inlet Velocity
Outlet pipe
Diam ID/OD/t
Outlet Velocity
Water Valve
p Outlet
Kv calc
Inlet pipe
Diam ID/OD/t
Velocity

Page 1/2

[-]
[DN]
[mm]
[m/s]
[DN]
[mm]
[m/s]

741.9
551.1
300 STD
304.74/323.8/9.53
67.5
49.7
450 STD
437.94/457/9.53
52.9
53.5

642.0

[bar a]
[-]
[DN]
[mm]
[m/s]

4.03
0.53
25 STD
26.64/33.4/3.38
1.4

4.75
0.74

5.77
1.07

1.9

2.7

Design
10.00
275.0

2.53
264.2

45.00
55.0

58.1

54.1

System design consideration CCI document "Installation Guidelines II500.0o/5en"


Application wizard
Industry
Process Id
Application

Pure power plant (PP)


Power/Combined Cycle dual pressure non reheat with water condensor (212212)
LP Bypass to condenser (R)

Note: Special Design Dual Inlet !

PowerSIZ 1.3S

Selected CCI

Steam conditioning equipment.

Reference No.
Date / Rev. / User Id :

V299356.60.80

Page 2/2

2009-04-07 / A / Hillenaar, Maarten

Tag No.

LP-SCV

Valve type

VLB - 180TC

Valve design
No. of pressure reducing stages
Seat
Leakage class
Kvc
[-]
Kvs
[-]
Control plug type
Characteristic
Spare capacity
[%]
Full Stroke
[mm]
Actuating force
[kN]
Shut-off-p
[bar a]
Desuperheater
Connections
Inlet
[DN]
Rating
Outlet
[DN]
Rating
Water inlet
[DN]
Rating
Materials
Inlet
Body
Outlet
Water connection
Stem
Plug
Seat
Packings
Design code

Single-seated
3
180
V
742
816
Fixed Cage
Modified Linear
10
160
36.4
10.0
OP2025/3

Actuator type

STI SC/V 320-200

Model
Stroke / MaxForce
[mm/kN]
Positioner / Air supply conn
Stroking time Mod / QO / QC
Power supply
Input signal
Increasing signal
Power supply failure
Accessories

Pneumatic Piston
200 / 38.5
FastTrak / 1/2"
6.0 s / NA / 3.0 s
5.0 bar(g)
4-20 mA
Valve opens
Valve closes
1 Limit switch opened
1 Limit switch closed
1 Air bottle
1 Trip valve
1 Position transmitter (Integrated in positioner)
1 Solenoid valve
1 Air filter regulator
2 Gauge
1 Tropical design
1 Junction box, Plastic

300 BWE
DIN 2559, Fig. 22
450 BWE
DIN 2559, Fig. 22
25 BWE
DIN 2559, Fig. 22
EN 10222-2 P250GH
EN 10222-2 P250GH
EN 10216-2 P235GH
EN 10222-2 P250GH
X19CrMoVNbN11-1
X19CrMoVNbN11-1
X10CrMoVNb9-1 / C21 coating
Graphite
EN 12516-2

Notes:
IP65
Tag No.

LP-DT

Dumping device

D-tube WCC

No of stages
Kvs
Material
Diameter / Length

[-]
[mm/mm]

1
1446
EN 10216-2 13CrMo4-5
450 / 600
PowerSIZ 1.3S