You are on page 1of 2

DEPRTMENT OF MECHANICAL ENGINEERING

CMR TECHNICAL CAMPUS


Kandlakoya (V), Medchal (M), Hyderabad 501 401

M TECH II SEM - II MID INTERNAL - QUESTION BANK


REFRIGERATION AND AIR CONDITIONING
UNIT-III
Short Answer Questions
1.

What are the advantages and disadvantages of Steam jet


refrigeration system?

2.

Define the following efficiencies used in Steam jet refrigeration


system a) Nozzle efficiency b) Entrainment efficiency c) Compression efficiency
Long Answer Questions
1. Explain the working of Steam jet refrigeration system with neat sketch.
2. Explain briefly analysis of Steam jet refrigeration system using using T-s and h-s
diagrams?

UNIT-IV
Short Answer Questions
1. What are the factors affecting Optimum Effective temperature?
2. What are the essential equipments used in an Air conditioning system?
3. What are the factors affecting comfort air conditioning?
Long Answer Questions
1. Briefly explain the following with neat sketch a) Sensible Heating b) Sensible Cooling
2. The atmosphere air at 760mm of Hg , dry bulb temperature 15 0c and wet bulb
temperature 110c enters a heating coil whose temperature is 41 0c. Assuming by pass
factor of heating coil as 0.5. Determine dry bulb and wet bulb temperature , Relative
humidity of air leaving the coil . Also determine the sensible heat added to the air per kg
of dry air.
3. Briefly explain the Summer air conditioning system with neat sketch ?
4. The amount of air supplied to an air conditioned hall is 300m 3/min .The atmospheric
conditions are 350c DBT and 55% RH . The required conditions are 200c DBT and 60%
RH . Find out the sensible heat and latent heat removed from the air per minute. Also
find sensible heat factor for the system.

UNIT-V
Short Answer Questions

1.

Define the following a) Relative humidity b) Specific humidity c) Degree of


saturation

2.

Define the following a) ADP b) Grand sensible heat factor (GSHF) c) Effective room
sensible heat factor (ERSH)

3.

Define the following a) Fan air power b) Fan efficiency

Long Answer Questions


1. What is By Pass factor of heating and cooling coil and derive the expression for it?
2. Explain briefly Cooling and dehumidification with neat sketch ?
3. The atmospheric air at 300c DBT and 75 % RH enters a cooling coil at the rate of
200m3/min . The coil dew point temperature is 14 0c and By pass factor of the coil is 0.1.
Determine 1)The temperature of air leaving the coil 2)The capacity of cooling coil in tones of
refrigeration and in killo watt 3)The amount of water vapour removed per minute 4) the
sensible heat factor for the process.
4.The moist air enters a chamber at 5 0c DBT and 2.50cWBT at the rate of 90 m 3/min . The
barometric pressure is 1.01325 bar . While passing through the chamber the air absorbs
sensible heat at the rate of 40.7 KW and picks up 40kg/hr of saturated steam at
1100c.Determine the DBT and WBT of leaving air.