You are on page 1of 3

Control Valve Calculation Sheet

Item No.

19

Ref No.

Tag No.

PCV-WRU-A/B

Purchaser

PT. PRATIWI PUTRI SULUNG

Service

Case 1 - 11/11/15

End User

PT. PGN

Project
Unit

PCV & PSDV WARU

Valve specification Model

ACN
(inch)

8 in.

Port size

(inch)

6 in.

Flow characteristic
Process data

Size

ANSI600

(inch)

Sch No.

INEAR(EQ% by POSITIONER Thickness

Fluid name
Condition

(mm)

10 in.

140

140

25.4

25.4
GAS

Unit

MAX

NOR

MIN

80

60

37

Inlet pressure

barG

26

30

40

Outlet pressure

barG

20

20

20

77.66

77.66

77.66

MW

16.246487

16.246487

16.246487

cP

0.011709

0.011709

0.012135

Specific heat ratio

1.372878

1.372878

1.439504

Compression factor

0.950727

0.950727

0.915442

248

140.5

55.83

Temperature
Gravity/Density(Liquid)

bar
degF
kg/m3

Gravity/Density(Gas or Vaper)
Viscosity
Vapor pressure
Critical pressure

barA
barA

Flash

Calculated CV
Rated CV

330

Travel

70

42

20

Sound pressure level

dBA

76

77

80

Outlet velocity

Mach

0.0909

0.06817

0.04106

Saturated temperature

degF

Reynolds number factor


Differential pressure ratio
<MAX>

CV =

Downstream

10 in.

Differential pressure

Factors

Upstream

MMscfd

Flow rate

Calculated value

PCV

Piping specification

Nominal size
Rating

1/3

Page

0.2221

0.3224

0.4877

Typical flow characteristic graph

CV%
100

94400m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)


22.5 x 0.9995 x 2701kPa x 0.903 x Sqr(0.2221)

= 248

MAX

<NOR>

50
NOR

CV =

70800m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)


22.5 x 0.9998 x 3101kPa x 0.8638 x Sqr(0.3224)

= 140.5

<MIN>

CV =

MIN

43660m3/h[S] x Sqr(16.25 x 298.5degK x 0.915442)


22.5 x 1 x 4101kPa x 0.8086 x Sqr(0.4877)

= 55.83

50
Travel %

100

A calculation result may be different from an actual case depending


on the piping and operation conditions. It should be an reference
data, accordingly.

Azbil Corporation

11/11/2015

Control Valve Calculation Sheet


Item No.

20

Ref No.

Tag No.

PCV-WRU-A/B

Purchaser

PT. PRATIWI PUTRI SULUNG

Service

Case 1 - 11/11/15

End User

PT. PGN

Project
Unit

PCV & PSDV WARU

Valve specification Model

ACN
(inch)

8 in.

Port size

(inch)

6 in.

Flow characteristic
Process data

Size

ANSI600

(inch)

Sch No.

INEAR(EQ% by POSITIONER Thickness

Fluid name
Condition

(mm)

10 in.

140

140

25.4

25.4
GAS

Unit

MAX

NOR

MIN

80

60

13

Inlet pressure

barG

40

30

23

Outlet pressure

barG

20

20

20

77.66

77.66

77.66

MW

16.246487

16.246487

16.246487

cP

0.011709

0.011709

0.012135

Specific heat ratio

1.372878

1.372878

1.439504

Compression factor

0.950727

0.950727

0.915442

125.1

140.5

56.29

bar

Temperature
Gravity/Density(Liquid)

degF
kg/m3

Gravity/Density(Gas or Vaper)
Viscosity
Vapor pressure
Critical pressure

Flash

barA
barA

Calculated CV
Rated CV
Travel

330
%

38

42

20

Sound pressure level

dBA

84

77

61

Outlet velocity

Mach

0.0909

0.06817

0.01443

Saturated temperature

degF

Reynolds number factor


Differential pressure ratio
<MAX>

CV =

Downstream

10 in.

Differential pressure

Factors

Upstream

MMscfd

Flow rate

Calculated value

PCV

Piping specification

Nominal size
Rating

2/3

Page

0.4877

0.3224

0.1249

Typical flow characteristic graph

CV%
100

94400m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)


22.5 x 0.9999 x 4101kPa x 0.795 x Sqr(0.4877)

= 125.1

<NOR>

50
NOR
MAX

CV =

70800m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)


22.5 x 0.9998 x 3101kPa x 0.8638 x Sqr(0.3224)

= 140.5

<MIN>

CV =

MIN

15340m3/h[S] x Sqr(16.25 x 298.5degK x 0.915442)


22.5 x 1 x 2401kPa x 0.951 x Sqr(0.1249)

= 56.29

50
Travel %

100

A calculation result may be different from an actual case depending


on the piping and operation conditions. It should be an reference
data, accordingly.

Azbil Corporation

11/11/2015

Control Valve Calculation Sheet


Item No.

21

Ref No.

Tag No.

PCV-WRU-A/B

Purchaser

PT. PRATIWI PUTRI SULUNG

Service

Case 1 - 11/11/15

End User

PT. PGN

Project
Unit

PCV & PSDV WARU

Valve specification Model

ACN
(inch)

8 in.

Port size

(inch)

6 in.

Flow characteristic
Process data

Size

ANSI600

(inch)

Sch No.

INEAR(EQ% by POSITIONER Thickness

Fluid name
Condition

(mm)

10 in.

140

140

25.4

25.4
GAS

Unit

MAX

NOR

MIN

80

60

15

Inlet pressure

barG

40

30

24

Outlet pressure

barG

20

20

20

77.66

77.66

77.66

MW

16.246487

16.246487

16.246487

cP

0.011709

0.011709

0.012135

Specific heat ratio

1.372878

1.372878

1.439504

Compression factor

0.950727

0.950727

0.915442

125.1

140.5

55.92

Temperature
Gravity/Density(Liquid)

bar
degF
kg/m3

Gravity/Density(Gas or Vaper)
Viscosity
Vapor pressure
Critical pressure

barA
barA

Flash

Calculated CV
Rated CV

330

Travel

38

42

20

Sound pressure level

dBA

84

77

64

Outlet velocity

Mach

0.0909

0.06817

0.01664

Saturated temperature

degF

Reynolds number factor


Differential pressure ratio
<MAX>

CV =

Downstream

10 in.

Differential pressure

Factors

Upstream

MMscfd

Flow rate

Calculated value

PCV

Piping specification

Nominal size
Rating

3/3

Page

0.4877

0.3224

0.1599

Typical flow characteristic graph

CV%
100

94400m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)


22.5 x 0.9999 x 4101kPa x 0.795 x Sqr(0.4877)

= 125.1

<NOR>

50
NOR
MAX

CV =

70800m3/h[S] x Sqr(16.25 x 298.5degK x 0.950727)


22.5 x 0.9998 x 3101kPa x 0.8638 x Sqr(0.3224)

= 140.5

<MIN>

CV =

MIN

17700m3/h[S] x Sqr(16.25 x 298.5degK x 0.915442)


22.5 x 1 x 2501kPa x 0.9372 x Sqr(0.1599)

= 55.92

50
Travel %

100

A calculation result may be different from an actual case depending


on the piping and operation conditions. It should be an reference
data, accordingly.

Azbil Corporation

11/11/2015

You might also like