You are on page 1of 752

1

Hydraulic-Components
for industrial applications
Part 4: Electronics and
electro-hydraulic systems

Catalogue for the product range of hydraulic components


by Bosch Rexroth, Hydraulics
Industrial applications

Part 1: Hydraulic pumps and motors

RE 00112-01

Industrial applications

Part 2: On/off valves


Isolator, directional, pressure and flow valves

RE 00112-02

Industrial applications

Part 3: Proportional, high-response and servo-valves


Directional, pressure and flow valves

RE 00112-03

Industrial applications

Part 4: Electronics
and electro-hydraulic systems

RE 00112-04

Industrial applications

Part 5: Control plates, hydraulic power units


and accessories

RE 00112-05

Industrial applications

Part 6: Hydraulic cylinders

RE 00112-06

Industrial applications

Part 7: ATEX units


for potentially explosive atmospheres

RE 00112-07

Mobile applications

Part 1: Axial piston units, gearboxes,


mobile electronics

RE 90005-01

Part 2: External gear units, radial piston motors,


mobile controls

RE 90005-02

Mobile applications

2
Bosch Rexroth AG

Hydraulics

RE 00112-04

Publisher

Bosch Rexroth AG
Hydraulics
D-97813 Lohr a. Main
Zum Eisengieer 1 D-97816 Lohr a. Main
Phone

++49 (0) 93 52/18-0

Fax

++49 (0) 93 52/18-23 58

Telex

6 89 418-0

eMail

documentation@boschrexroth.de

Internet www.boschrexroth.de
Catalogue No.

RE 00112-04/11.05
Replaces: 04.03

Printers

Schleunungdruck GmbH
97828 Marktheidenfeld
Reprints and translation, in whole or in part, only with the
publishers prior consent.
Subject to revision.

Should you have queries with regard to the


products in this catalogue, please contact
the Rexroth sales partner in your vicinity.

3
RE 00112-04

Hydraulics Bosch Rexroth AG

Table of contents

Page

Amplifiers and
command value conditioning

7 360

Electronics and electro-hydraulic systems

01

Control cards and units

361 448

02

Sensors and signal transmitters

449 530

03

Electronic accessories

531 658

04

Electro-hydraulic systems

659 746

05

4
Bosch Rexroth AG

Hydraulics

RE 00112-04

Electronics and
electro-hydraulic systems
Electronics

 Amplifiers and
command value conditioning
 Control cards and units
 Sensors und signal transmitter
 Electronic accessories

Electro-hydraulic
systems
 Closed loop control systems
for hydraulic pumps
 Accessories

7
RE 00112-04

Hydraulics Bosch Rexroth AG

Amplifiers and command value conditioning

Type

Series

Data
sheet no.

Electric amplifiers
(for valves: DBETFX, DREB6X, DBEB10Z, DREB10Z, DBETBX,
4WRP6EA, 3FREZ, 4WRP10EA)

VT-VRPA1-5...

1X

30052

11

Electric amplifiers
(for valves: DBETFX, DREB6X, DBEB10Z, DREB10Z, DBETBX,
4WRP6EA, 3FREZ, 4WRP10EA)

VT-VRPA1-5...RTP

1X

30054

17

Electric amplifiers
(for valves: DBETFX, DREB6X, DBEB10Z, DREB10Z, DBETBX,
4WRP6EA, 3FREZ, 4WRP10EA)

VT-VRPA1-5...RTS

1X

30056

23

Analogue amplifier
(for valves: DBETR1X, 2FRE)

VT-VRPA1-100

1X

30118

29

Analogue amplifiers
(for valves: FE, FES)

VT-VRPA1-50 bis
VT-VRPA1-52

1X

30117

37

Analogue amplfier card for 4/3 prop. directional valves of type 4WRE

VT-VRPA2-1

1X

30119

45

Electric amplifier
(for valves: 4WRP)

VT-VRPA2...RTP

1X

30048

55

Electric amplifiers
(for valves: 4WRP)

VT-VRPA2...RTS

1X

30047

61

Electric amplifiers
(for valves: 4WRPH)

VT-VRRA1-5...

2X

30040

67

Electric amplifiers
(for valves: 4WRPH)

VT-VRRA1-...KV-AGC

2X

30046

73

Electric amplifiers
(for valves: 4WRPH)

VT-VRRA1-527-10/V0

1X

30042

79

Electric amplifiers
(for two valves: 4WRPH)

VT-KRRA2-5.../2CH

2X

30049

85

Electric amplifiers
(for valves: 4WRPL)

VT-VRRA1-527-2X/V0/
2STV

2X

30045

91

Electric amplifiers
(for valves: 4WRL)

VT-VRRA1-527-2X/V0/
K40-AGC-2STV

3X

30043

97

Electric amplifiers
(for valves: 4WRL)

VT-VRPA1-527-2X/V0/
RTS-2STV

2X

30044

103

Electric amplifier
(for valves: 4WRPH, 5WRP)

VT-VRRA1, VT-VRPA1

2X

30041

109

Electric amplifier
(for valves: DBE, DBETX, DRE, 2FRE, 4WRBA)

VT-VSPA1-5.../RTP

1X

30109

115

Electric amplifier
(for prop. pressure valves without electrical position feedback)

VT-VSPA1-1,
VT-VSPA1(K)-1

1X

30111

121

Electric amplifier
(for valves: DBET, also all-purpose)

VT-VSPA1-2,
VT-VSPA1K-2

1X

30115

133

Analogue amplifier card


(for valves: 4WRA, 4WRZ)

VT-VSPA2-1

2X

30110

143

Designation

Page

Amplifiers, analogue, Euro-card format

01

03

04

05

Continued on next page

06

8
Bosch Rexroth AG

Hydraulics

RE 00112-04

Amplifiers and command value conditioning

Type

Series

Data
sheet no.

Electrical amplifier for flow control with proportional valves


(for pumps A4VSO, A4VSG)

VT5035

1X

29955

153

Electronic Amplifier for Setting the Output Flow


of Axial Piston Pumps A10VSO

VT5036

1X

29957

159

Electrical amplifier for the control of servo valves


with electrical position feedback
(for valves: 4WS2EE)

VT-SR1

1X

29979

165

Analogue amplifier
(for valves: 4WS2EM, 4WS2EB10, 4DS1EO2, 3DS2EH10)

VT-SR2

1X

29980

171

Electrical amplifier for the control of high response control valves


with a servo pilot control valve
(for valves: WRC)

VT-SR41 bis VT-SR48

1X

30209

177

Electrical amplifier for flow control with servo-valves


(for pumps A4VS...HS)

VT-SR7

1X

29993

183

Analogue amplifier module


(for valves: (Z)DRS6)

VT-MRMA1-1

1X

30214

187

Analogue amplifier module


(for valves: DBETR, 2FRE)

VT-MRPA1-100

1X

30221

195

Analogue amplifier modules for 4/3 and 4/2 proportional


directional valves 4WRE

VT-MRPA2,
VT-MRPA1-2

1X

30219

203

Amplifier module for proportional valves


(for valves: DBE, DBETX, DRE, 2FRE, 4WRBA)

VT-MSPA1-5...

1X

30222

213

Analogue amplifier module


(for valves: DBET, KBPS)

VT-MSPA1-1

1X

30223

219

Analogue amplifier module


(for valves: KKS1NA, KKS1PA)

VT-MSPA1-50

1X

30225

225

Analogue amplifier module


(for valves: 4WRA)

VT-MSPA2-1

1X

30228

229

Amplifier module for controlling explosion-protected proportional


directional valves 4WRA...XE, 3DREP 6...XE and 4WRZ...XE

VT-MSPA2-200

1X

30228-200

237

Electrical amplifier module for controlling proportional throttle


valves with electrical position feedback
(for valves: FES25C)

VT11037

1X

29756

245

Analogue amplifier modules


(for valves: (Z)DBE6, DBE(M)10, DBE(M)20, ZDRE10, (Z)DRE 6)

VT11131, VT11132

1X

29865

251

Analogue amplifier modules


(for valves: DRE4K-3X/)

VT11004, VT11015
und VT11026

1X

30226

255

Electrical amplifier modules for controlling proportional


and on/offvalves
(for valves: DRE4K with 3WE4)

VT11550 bis VT11554

2X

29870

261

Designation

Page

Amplifiers, analogue, Euro-card format (continued)

Amplifiers, analogue, modular design

9
RE 00112-04

Hydraulics Bosch Rexroth AG

Amplifiers and command value conditioning

Type

Series

Data
sheet no.

Analogue amplifier module


(for valves: 3DRE(M), DRE(M))

VT11724

1X

29866

269

Electrical amplifier module for the flow control of a variable displacement axial piston pump with electrical position feedback
(for pumps A10VSOFE)

VT11019

1X

29763

273

Analogue amplifier module


(for valves: 4WS2EM)

VT11021

1X

29743

279

Plug amplifier module for proportional valves


(for valves: DBE, DBETX, DRE, 2FRE, 4WRBA)

VT-SSPA1-508
VT-SSPA1-525

2X

30264

283

Plug-in proportional amplifier


(for valves: DBET, also all-purpose)

VT-SSPA1-1,
VT-SSPA1-50

1X

30265

291

Plug-in proportional amplifier


(for valves: KBPS..8, KKDSR1, KKDSR2)

VT-SSPA1-5,
VT-SSPA1-100

1X

30116

299

Designation

Page

Amplifiers, analogue, modular design (continued)

01

Amplifiers, analogue, plug design

03

Amplifiers, digtal, Euro-card format


Digital valve amplifier for valve types 4WRE 6,
component series 2X and 4WRE 10, component series 2X

VT-VRPD

2X

30126

307

Announcement for the 2nd quarter 2006,


phone: +49 (9352)18-1023
Digital amplifier

VT-VSPD-1

2X

30523

Analog command value card (diff. command value conditionings)

VT-SWKA1

1X

30255

315

Setpoint signal card

VT-SWKA1-5

1X

30282

323

Setpoint and voltage-controlled ramp generator

VT-SWKA3-5

1X

30281

329

VT-SWMA-1

1X

29902

335

Command value conditioning, Euro-card format

04

Command value conditioning, modular design


Analogue command value module (call-ups, ramps)
Analogue command value module (charcteristic curve adj.)

VT-SWMAK-1

1X

29903

341

Current/voltage signal transformer module

VT-SWMA1-5

1X

30284

347

Signal adjustment module (charcteristic curve adj.)

VT-SWMA2-5

1X

30283

351

VT-SSV-1

2X

30262

05

Switching amplifier
Plug-in switching amplifier
(for switching valves)

357

06

10
Bosch Rexroth AG

Hydraulics

RE 00112-04

11

RE 30052/08.05
Replaces: 05.04

Electric amplifiers

1/6

Type VT-VRPA1

Unit series 1X

List of contents
Contents

Features
Page

Analog amplifiers in Eurocard format for installation in 19 rack

Features

Output stage with closed-loop control

Ordering data

Closed-loop position control with PID action

Preferred types

Rapid energizing and de-energizing for fast response times

Front panel

Enabling input

Circuit diagram with pin assignment

Short-circuit-proof outputs

Technical data

Open-circuit detection for feedback signal cable

Unit dimensions

Zero and sensitivity adjustment possibilities


Testing and service equipment
Test box type VT-PE-TB1, see RE 30063
Test adapter type VT-PA-3, see RE 30070

12
2/6

Bosch Rexroth AG

Hydraulics

VT-VRPA1

RE 30052/08.05

Ordering data

VT

1X V0

Hydraulic component
For valves with electrical
feedback
=R
Valve type
4/2 servo solenoid valves
with positive overlap
Actuation
Analog
Output stages
1 output stage

PV =
QV =
V0 =
=P

Customer version
Catalog version
Unit series
Unit series 10 to 19

1X =
=A
=1

Option
Pressure valves
Throttle/flow control valves

Serial number for type


2.7 A solenoid
3.7 A solenoid

527 =
537 =

Preferred types

Type

Material Number

For valve types

VTVRPA152710/V0

0 811 405 095

DBETFX

VTVRPA152710/V0/PV

0 811 405 096

DREB6X

VTVRPA153710/V0/PV

0 811 405 097

DBEB10Z / DREB10Z / DBETBX

VTVRPA152710/V0/QV

0 811 405 098

4WRP6EA / 3FREZ

VTVRPA153710/V0/QV

0 811 405 099

4WRP10EA

13
RE 30052/08.05

VT-VRPA1

Hydraulics

Bosch Rexroth AG

3/6

Front panel

01

14
4/6

Bosch Rexroth AG

Hydraulics

Circuit diagram with pin assignment

VT-VRPA1

RE 30052/08.05

15
RE 30052/08.05

VT-VRPA1

Hydraulics

Bosch Rexroth AG

5/6

Technical data
P.C.B. format

mm (100 x 160 x approx. 35) / (W x L x H)


Europe format with front panel (7 modular spacings)

Plug connector

Connector DIN 41612F32

Ambient temperatur

C 0...+70, storage temperature min. 20; max. +70

Power supply
UB to b 16/b 18
and b 2/b 4 (0 V)

24 V DC
Battery voltage 21...24 V, Rectified AC voltage
Ueff = 21...28 V (single-phase, full-wave rectification)

Smoothing capacitor, separately


to b 28/b 30 b 2/b 4

4700 F, 63 V (ELKO) if ripple >10 %

Solenoid

A/W 2.7/25

Power consumption, max.


Current rating, max.

3.7/50

W 35

60

A 1.5

2.5

Solenoid output
b 6 b 8

Square-wave voltage, pulse-modulated

Setpoint

UE III : 0...+10 V
UE III : 0 V
UE III : 0...+10 V
UE III : 0...+10 V

Signal source (setpoint)

Potentiometer R = 1 k
+10 V supply from b 32 (10 mA) or external source

Imax. = 2.7 A

Imax. = 3.7 A
(z 10)
(z 12)

Differential
input

Oscill. b 26

Test pt. z 28*

0 811 405 095

10.2 Veff / 7.8 kHz

0...+10 V DC

0 811 405 096

10.2 Veff / 7.8 kHz

0...+10 V DC

0 811 405 097

10.8 Veff / 7.8 kHz

0...+10 V DC

0 811 405 098

10.2 Veff / 7.8 kHz

0...+10 V DC

0 811 405 099

10.8 Veff / 7.8 kHz

0...+10 V DC

Actual value feedback

Output stage enable

To z 16, U = 8.5...40 V; e.g. 10 V from z 32


LED (green) on front panel lights up

Cable lengths and cross-sections

Solenoid: < 20 m
1.5 mm2
Solenoid: 20...50 m 2.5 mm2
Position transducer: max. 50 m at 100 pF/m
Supply and capacitor 1.5 mm2

LED displays

green: Enable
yellow: Feedback signal open circuit
red: UB < UB min. (approx. 21 V)

Fault indication
Feedback signal open circuit
UB too low
15 V stabilization

z 26: Switching output


No fault +24 V (max. 100 mA)
Fault 0 V

Short-circuit-proof outputs

Output stage to solenoid


Signal to position sensor
Potentiometer supply

Special features

Open-circuit protection for feedback signal cable


Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times

Adjustment via trimming potentiometer

1. Zero
2. Sensitivity

Note
Power zero b 2 and control zero b 12 must be bridged. At a distance of < 1 m from power supply, connect directly to DIN
connector.
At greater distances, connect control zero separately to ground.
* 0 V at Im = 0 V (enable OFF)
+10 V at Im = max. (UE = 10 V, potentiometer = cW)

01

16
6/6

Bosch Rexroth AG

Hydraulics

VT-VRPA1

RE 30052/08.05

Unit dimensions (nominal dimensions in mm)

Connector DIN 41612F32

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not release
the user from the obligation of own judgement and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

17

RE 30054/08.05
Replaces: 05.04

Electric amplifiers

1/6

Type VT-VRPA1...RTP

Unit series 1X

List of contents
Contents

Features
Page

Analog amplifiers in Eurocard format for installation in 19 rack

Features

Output stage with closed-loop control

Ordering data

Closed-loop position control with PID action

Preferred types

Rapid energizing and de-energizing for fast response times

Front panel

Enabling input

Circuit diagram with pin assignment

Ramp can be adjusted and deactivated

Technical data

Open-circuit detection for feedback signal cable

Unit dimensions

Short-circuit-proof outputs
Adjustment possibilities for zero and sensitivity, acceleration
and braking ramps
Testing and service equipment
Test box type VT-PE-TB1, see RE 30063
Test adapter type VT-PA-3, see RE 30070

18
2/6

Bosch Rexroth AG

Hydraulics

VT-VRPA1...RTP

RE 30054/08.05

Ordering data

VT

1X V0

RTP

Hydraulic component
For valves with
electrical feedback = R

RTP =

Valve type
4/2 servo solenoid valves
with positive overlap
=P
Actuation
Analog

Option
Ramp, adjusted and deactivated
by potentiometer

PV =
QV =
=A

Output stages
1 output stage

V0 =
=1

Option
Pressure valves
Throttle/flow control valves
Customer version
Catalog version
Unit series
Unit series 10 to 19

1X =

Serial numbers for type


2.7 A solenoid
3.7 A solenoid

527 =
537 =

Preferred types
Type

Material Number

For valve types

VTVRPA152710/V0/RTP

0 811 405 100

DBETFX

VTVRPA152710/V0/PVRTP

0 811 405 101

DREB6X

VTVRPA153710/V0/PVRTP

0 811 405 102

DBEB10Z / DREB10Z / DBETBX

VTVRPA152710/V0/QVRTP

0 811 405 103

4WRP6EA / 3FREZ

VTVRPA153710/V0/QVRTP

0 811 405 104

4WRP10EA

19
RE 30054/08.05

VT-VRPA1...RTP

Hydraulics

Bosch Rexroth AG

3/6

Front panel

01

20
4/6

Bosch Rexroth AG

Hydraulics

Circuit diagram with pin assignment

VT-VRPA1...RTP

RE 30054/08.05

21
RE 30054/08.05

VT-VRPA1...RTP

Hydraulics

Bosch Rexroth AG

5/6

Technical data
P.C.B. format

mm (100 x160 x approx. 35) / (W x L x H)


Europe format with front panel (7 modular spacings)
Plug connector
Connector DIN 41612F32
Ambient temperature
C 0...+70, storage temperature min. 20; max. +70
24 V DC
Power supply
Battery voltage 21...24 V, Rectified AC voltage
UB to b 16/b 18
and b 2/b 4 (0 V)
Ueff = 21...28 V (single-phase, full-wave rectification)
Smoothing capacitor, separately
4700 F, 63 V (ELKO)
to b 28/b 30 b 2/b 4
if ripple > 10 %
Solenoid
A/W 2.7/25
3.7/50
Power consumption max.
W 35
60
Current rating max.
A 1.5
2.5
Square-wave voltage, pulse-modulated
Solenoid output
b 6 b 8
Imax = 2.7 A
Imax = 3.7 A
Setpoint
UE III: 0...+10 V
(z 10) Differential
UE III: 0 V
(z 12) input
UE III: 0...+10 V
UE III: 0...+10 V
Signal source (setpoint)
Potentiometer R = 1 k
+10 V supply from b 32 (10 mA) or external source
Oscill. b 26
Test pt. z 28*
Actual value feedback
0 811 405 100
0...+10 V DC
10.2 Veff / 7.8 kHz
0...+10 V DC
0 811 405 101
10.2 Veff / 7.8 kHz
0...+10 V DC
0 811 405 102
10.8 Veff / 7.8 kHz
0...+10 V DC
0 811 405 103
10.2 Veff / 7.8 kHz
0...+10 V DC
0 811 405 104
10.8 Veff / 7.8 kHz
Output stage enable
To z 16, U = 8.5...40 V; e.g. 10 V from z 32
LED (green) on front panel lights up
Ramp OFF
To b 20; U = 8.5...40 V
Cable lengths and cross-sections
Solenoid: < 20 m
1.5 mm2
Solenoid: 20...50 m 2.5 mm2
Position transducer: max. 50 m at 100 pF/m
Supply and capacitor 1.5 mm2
LED displays
green: Enable
yellow: Feedback signal open circuit
yellow: Ramp OFF
red: UB < UB min (approx. 21 V)
Fault indication
z 26: Switching output
Feedback signal open circuit
No fault +24 V (max. 100 mA)
UB too low
Fault 0 V
15 V stabilization
Short-circuit-proof outputs
Output stage to solenoid
Signal to position sensor
Potentiometer supply
Special features
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Ramp, can be adjusted and deactivated
Adjustment via trimming potentiometer
1. Zero
2. Sensitivity
3. Acceleration ramp
4. Braking ramp
Note
Power zero b 2 and control zero b 12 must be bridged. At a distance of < 1 m from power supply, connect directly to
DIN connector. At greater distances, connect control zero separately to ground.
* 0 V at Im = 0 V (enable OFF)
+10 V at Im = max. (UE = 10 V, potentiometer = cW)
Note for the use of ramps
Ramp ON: No signal to b 20.
Rampe OFF: 8.5...40 V to b 20 or connection between b 22 and b 20.
Ramp OFF or open circuit interrupts a ramp in progress. There is an abrupt transition to the signal output value.

01

22
6/6

Bosch Rexroth AG

Hydraulics

VT-VRPA1...RTP

RE 30054/08.05

Unit dimensions (nominal dimensions in mm)

Connector DIN 41612F32

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not release
the user from the obligation of own judgement and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

23

RE 30056/08.05
Replaces: 01.05

Electric amplifiers

1/6

Type VT-VRPA1...RTS

Unit series 1X

List of contents
Contents

Features
Page

Analog amplifiers in Eurocard format for installation in 19 rack

Features

Output stage with closed-loop control

Ordering data

Closed-loop position control with PID action

Preferred types

Rapid energizing and de-energizing for fast response times

Front panel

Enabling input

Technical data

Disconnectible voltage-controlled or manually adjustable


ramps

Unit dimensions

Open-circuit detection for feedback signal cable

Circuit diagram with pin assignment

3 and 4

Short-circuit-proof inputs and outputs


Adjustment possibilities for zero and sensitivity, accelerating
and braking ramps
Testing and service equipment
Test box type VT-PE-TB1, see RE 30063
Test adapter type VT-PA-3, see RE 30070

24
2/6

Bosch Rexroth AG

Hydraulics

VT-VRPA1...RTS

RE 30056/08.05

Ordering data
VT

Hydraulic component
For valves with electrical
feedback

1X V0

RTS

RTS =
=R

Valve type
4/2 servo solenoid valves
with positive overlap
Actuation
Analog
Output stages
1 output stage

=P

Option
Disconnectible voltage-controlled
or manually adjustable ramps
(potentiometer)

PV =
QV =
=A
V0 =
=1
1X =
527 =
537 =

Preferred types
Type

Material Number

VTVRPA152710/V0/RTS

0 811 405 175

DBETFX

VTVRPA152710/V0/PVRTS

0 811 405 176

DREB6X

VTVRPA153710/V0/PVRTS

0 811 405 179

DBEB10Z / DREB10Z / DBETBX

VTVRPA152710/V0/QVRTS

0 811 405 177

4WRP6EA / 3FREZ

VTVRPA153710/V0/QVRTS

0 811 405 178

4WRP10EA

Front panel

For valve types

Option
Pressure valves
Throttle/flow control valve
Customer version
Catalog version
Unit series
Unit series 10 to 19
Serial numbers for type
2.7 A solenoid
3.7 A solenoid

25
RE 30056/08.05

VT-VRPA1...RTS

Hydraulics

Bosch Rexroth AG

3/6

Circuit diagram with pin assignment

01

26
4/6

Bosch Rexroth AG

Hydraulics

Circuit diagram with pin assignment


Daughter card

VT-VRPA1...RTS

RE 30056/08.05

27
RE 30056/08.05

VT-VRPA1...RTS

Hydraulics

Bosch Rexroth AG

5/6

Technical data
Specifications
P.C.B. format

mm (100 x160 x approx. 35) / (W x L x H)


Europe format with front panel (7 modular spacings)
Plug connector
Connector DIN 41612F32
Ambient temperatur
C 0...+70, storage temperature min. 20; max. +70
24 V DC
Power supply
Battery voltage 21...24 V, rectified AC voltage
UB to b 16/b 18
and b 2/b 4 (0 V)
Ueff = 21...28 V (single-phase, full-wave rectification)
Smoothing capacitor, separately
4700 F, 63 V (ELKO)
to b 28/b 30 b 2/b 4
if ripple > 10 %
Solenoid
A/W 2.7/25
3.7/50
Power consumption, max.
W 35
60
Current rating, max.
A 1.5
2.5
Square-wave voltage, pulse-modulated
Solenoid output
Imax. = 3.7 A
Imax. = 2.7 A
b 6 b 8
Setpoint
UE III: 0...+10 V
(z 10) Differential
UE III: 0 V
(z 12) input
UE III: 0...+10 V
UE III: 0...+10 V
Signal source (setpoint)
Potentiometer R = 1 k
+10 V supply from b 32 (10 mA) or external source
Oscill. b 26
Test pt. z 28*
Actual value feedback
0 811 405 175
10.2 Veff / 7.8 kHz
0...+10 V DC
0 811 405 176
10.2 Veff / 7.8 kHz
0...+10 V DC
0...+10 V DC
0 811 405 179
10.8 Veff / 7.8 kHz
0 811 405 177
10.2 Veff / 7.8 kHz
0...+10 V DC
0...+10 V DC
0 811 405 178
10.8 Veff / 7.8 kHz
Output stage enable
To z 16, U = 8.5...40 V; e.g. 10 V from z 32
LED (green) on front panel lights up
Ramp OFF
To b 20; U = 8.5...40 V
Ramp internal/external
To z 24, U = 8.5...40 V
external ramp setpoint
Cable lengths and cross-sections
Solenoid: < 20 m
1.5 mm2
Solenoid: 20...50 m 2.5 mm2
Position transducer: max. 50 m at 100 pF/m
Supply and capacitor 1.5 mm2
LED displays
Green: enable
Green: external ramp
Yellow: feedback signal open circuit
Yellow: ramp OFF
Yellow: UA = 0 V
Red: UB < UB min (approx. 21 V)
Fault indication
z 26: Switching output
Feedback signal open circuit
No fault +24 V (max. 100 mA)
UB too low
Fault 0 V
15 V stabilization
Short-circuit-proof outputs
Output stage to solenoid
Signal to position sensor
Potentiometer supply
Special features
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Disconnectible ramp
Choice of internal or external ramp setpoint
Adjustment via trimming potentiometer
1. Zero
2. Sensitivity
3. Acceleration ramp
4. Braking ramp
5. Ramp setting range switchover
Caution:
Power zero b 2 and control zero b 12 must be bridged. At a distance of < 1 m from power supply, connect directly to DIN
connector. At greater distances, connect control zero separately to ground.
* 0 V at Im = 0 V (enable OFF)
+10 V at Im = max. (UE = 10 V, potentiometer = cW)

01

28
6/6

Bosch Rexroth AG

Hydraulics

VT-VRPA1...RTS

RE 30056/08.05

Unit dimensions (nominal dimensions in mm)

Connector DIN 41612F32

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not release
the user from the obligation of own judgement and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

29

RE 30118/11.04
Replaces: 04.04

Analogue amplifier

1/8

Type VT-VRPA1-

Component series 1X

H/A/D 6197/99

Overview of contents
Contents

Features
Page

Overview of contents

Features

Suitable for controlling direct operated proportional pressure


control valves with electrical position feedback, type DBETR,
and proportional flow control valves with electrical position
feedback, type 2FRE(G)

Ordering details

Functional description

Plug-in connections compatible with those of amplifier types


VT 5003, VT 5004 and VT 5010

Technical data

Power supply with raised zero point

Block circuit diagram / connection allocation

Display/adjustment elements

Command value signal inputs:


0 to + 6 V; 0 to + 9 V; 0 to + 10 V
0 to 20 mA; 4 to 20 mA (plug-in bridges)

Engineering/maintenance guidelines, additional information

Unit dimensions

Potentiometer adjustment on the front plate


for the zero point and amplitude attenuation
Measurement sockets for the ramp time
Enable input and ramp off input
Plug-in bridges for switching the maximum ramp times
0.02 to 5 s or 0.2 to 50 s

Card holder:
Type VT 3002-2X/32, see RE 29928
Single card holder without power supply
Power supply:
Type VT-NE30-1X, see RE 29929
Compact power supply 115/230 VAC 24 VDC, 70 VA

Outputs for command value (0 to + 6 V) and actual value (0 to 6 V)


LED display operational
Polarity protection

30
2/8

Bosch Rexroth AG

Industrial Hydraulics

VT-VRPA1-100

RE 30118/11.04

Ordering details
VT-VRPA1
Amplifier for proportional valves with electrical
feedback, analogue, with one output stage
Amplifier for proportional pressure valves
DBETR1X
2FRE 6
2FRE 10 and 16

1X V0

*
Further details in clear text

1X =
= 100
= 150
= 151

Component series 10 to 19
(10 to 19: unchanged techncial data
and connection allocation)

When replacing amplifier types VT 5003, VT 5004 or VT 5010


for rack installation, a 4TE/3HE dummy plate must be ordered
separately.
Material no.: R900021004

Functional description
Power supply
After the operating voltage has been applied the internal
power supply [6] supplies a voltage of 9 V compared to the
measurement zero (M0). This is compared to the load zero (L0)
raised by +9 V. The voltages +9 V and 9 V (9 V relates to
L0) are fed to the plug strip X1 and can thereby be externally
(e.g. for a command value potentiometer) used. The maximum
loading is 25 mA.

External command value potentiometer (with a 9 V


command value input)
26c

Input (+ 9 V

100 %)

16ac + 9 V

5K

18ac M0

Operational

Ramp function

The amplifier card is operational when the following conditions


have been fulfilled:
Operating voltage > 20 V
There is no unsymmetry in the internal supply voltages
No cable break in the position transducer cables
No short circuit in the solenoid cables

The subsequent ramp generator [3] produces from a jump


form of applied input signal an output signal in the form of a
ramp. The time constants of the output signal (ramp times) can
be adjusted by potentiometers t1 (upwards ramp) and t2
(downwards ramp) which are accessible via the front panel. The
maximum ramp time stated relates to a command value jump of
100 % and can, dependent on the plug-in bridge settings (X8,
X9), be either approx. 5 s or 50 s. If a command value signal is
applied onto the input of the ramp generator [3] that is less than
100 % then the ramp time is reduced accordingly. The actual
ramp time can be checked at the measurement sockets t1
(upwards ramp) and t2 (downwards ramp).

That the unit is operational is indicated by a green LED lighting


up on the front plate.
Command value
The command value signal is applied either directly from the
regulated +9 V of the power supply [6] or via an external
command value potentiometer. For the input command
value 1 +9 V = +100 % applies and for the input command
value 2 +6 V = +100 % applies. The reference point for the
command value inputs 1 and 2 is always M0 (18ac). Command value input 3 is a differential input [1] (0 to +10 V). It can
be configured as a current input (0 to 20 mA or 4 to 20 mA)
via plug-in bridges. If the command value signal comes from
external electroncis with a different reference potential then the
differential input is to be used.
When the command value voltage is applied or withdrawn
care has to be taken to ensure that both of the signal lines
are separated from the input or connected with it. All of the
command values are, before being switched, summated [2]
with regard to the value and pre-sign. With potentiometer Zw
it is possible to compensate for off-set voltages in the command
value branch.

For details see Technical data


External time potentiometer
30c
500K

32c

Note
When using an external time potentiometer the internal
potentiometers for the ramp times must be set to their maximum
(voltages at the measurement sockets t1 and t2 are approx.
20 mV). The maximum ramp time reduces as the resistance
value of the external potentiometer (approx. 500 k) is switched
in parallel to the internal potentiometers. In this case it is not
possible to separately adjust the ramp times for the up and
down ramps.
By applying a voltage >10 V at the switched input ramp off
or by setting the plug-in bridge X4 the ramp time is set to its
minimum value (approx. 15 ms). The switched input is then
ineffective. The minimum value then applies to both directions.

31
Industrial Hydraulics Bosch Rexroth AG

VT-VRPA1-100

RE 30118/11.04

3/8

Functional description (continued)


Calculating the ramp times
Plug-in bridge X9 is fitted
(short ramp time )
tup =
tdown
=

0.1
Ut1

(in s)

tup =

(in s)

tdown
=

0.1
Ut2

Position sensing
Plug-in bridge X8 is fitted
(long ramp time)

The position transducer electronics comprise of an oscillator


[14] with a subsequent driver [15] for controlling the inductive position transducer and a demodulator [16] for evaluating the position transducer signal (actual value). The oscillator
frequency is approx. 2.5 kHz. The inductive position transducer has
to be connected as a throttle circuit with mid sensing. The position
transducer electronics are factory pre-set. Very long or capasitive
position transducer cables can result in the zero point having to be
re-adjusted (via potentiometer Zx). The actual value (relates to the
position of the valve spool) can be measured at the actual value
measurement socket.

1
Ut1

(in s)

1
Ut2

(in s)

Ut1; Ut2 voltages at the measurement sockets t1 or t2 (in V)


Limiting and position controller
From the output of the ramp generator [3] the command value
signal is passed to potentiometer Gw, which is accessible via
the front panel, which acts as an attenuator. The maximum flow
of the valve can be thereby adjusted. The subsequent limiter
[7] limits the command value to + 105 % or 5 % (e.g. with a
command value that is too high or by adjusting the zero point
Zw potentiometer and the basic value Gw) so that the valve
spool is prevented from hitting the mechanical end position.
The output signal of the limiter [7] is the actual position signal
and is connected to the PID controllers [8] and via an output
stage [17] to the measurement socket w on the front plate
of the card as well as connection 28c on the plug strip X1
(command value to ramp and limiter). A voltage of +6 V at the
command value measurement socket w relates to a command
value of + 100 %. The PID controller is optimised specifically
to the requirements of DBETR and FRE valves. The controller
compares the position command value and the actual position value; in the case of differences, a corresponding control
output is fed to the current output stage [13], the output signal
of which controls the proportional solenoid of the valve.

Note
The actual value signal is inverted when compared to the command value. A travel of 100 % relates to 6 V at the actual value
measurement socket and at connection 32a on the plug strip
X1.
Enable input
With a signal > 10 V at the enable input 20a the output stage
and the I-controller are released (displayed via the yellow LED
on the front plate). By setting the plug-in bridge X3 they are
permanently released independent from the signal at the enable
input. The switched input is thereby ineffective.

[ ] = Cross reference to the block circuit diagam see page 5

Technical data (for applications outside these parameters, please consult us!)
Operating voltage
Functional range

UB 24 VDC + 40 % 5 %
Upper limiting value

UB(t)max 35 V

Lower limiting value

UB(t)min 22 V

Power consumption

Ps < 35 W
I < 1.5 A

Current consumption
Fuse
Inputs

Is 2.5 A T
Command value 1

Ue 0 V to + 9 V (ref. potential is M0)

Command value 2

Ue 0 V to + 6 V (ref. potential is M0)

Command value 3 (differential input)

Ue 0 V to + 10 V

Or

Ie 0 mA to 20 mA (Ri = 100 )

Or

Ie 4 mA to 20 mA (Ri = 100 )

Enable
Active

UF > 10 V

Not active

UF < 9 V
Continued on next page

01

32
4/8

Bosch Rexroth AG

Industrial Hydraulics

VT-VRPA1-100

RE 30118/11.04

Technical data (for applications outside these parameters, please consult us!)
Continued from page 3
Inputs

External ramp switch off


Without ramp

UR > 10 V

With ramp

UR < 9 V

Adjustment ranges
Zero point Zw

5 % up to max. + 30 %

Command value attenuation Gw

0 % to 105 %

Ramp time up
Short (bridge X9 fitted)

tup 1 < 20 ms to 5 s 20 % (Ut1: 0.02 V

approx. 5 s; 5 V

approx. 20 ms)

Long (bridge X8 fitted)

tup 2 < 0.2 s to 50 s 20 % (Ut1: 0.02 V

approx. 50 s; 5 V

approx. 0.2 s)

Ramp time down

Outputs

Short (bridge X9 fitted)

tdown 1 < 20 ms to 5 s 20 % (Ut2: 0.02 V

approx. 5 s; 5 V

approx. 20 ms)

Long (bridge X8 fitted)

tdown 2 < 0.2 s to 50 s 20 % (Ut2: 0.02 V

approx. 50 s; 5 V

approx. 0.2 s)

Output stage
Solenoid current/resistance

Clock frequency

Imax 2.2 A 10 % / R(20) = 10 (VT-VRPA1-100)


2.2 A 10 % / R(20) = 5.4 (VT-VRPA1-150)
2.2 A 10 % / R(20) = 10 (VT-VRPA1-151)
f Free clocking (approx. 1.5 kHz)

Driver for the inductive position transducer


Oscillator frequency
Regulated voltage

f 2.5 kHz 10 %
U 9 V 1% (with a raised zero point); 25 mA externally loadable

Measurement sockets
Command value w

Uw 0 V to + 6 V (Ri = 1k)

Actual value x

Ux 0 V to 6 V (Ri = 1k)

Upwards ramp t1

Ut1 0.02 V up to approx. 5 V (delayed adjustment range)

Downwards ramp t2

Ut2 0.02 V up to approx. 5 V (delayed adjustment range)

Connection type

32-pin blade connection, DIN EN 60603-2, form D

Card dimensions

Euro card 100 x 160 mm, DIN 41494

Front plate dimensions


Height

3 HE (128.4 mm)

Width solder side

1 TE (5.08 mm)

Width component side

3 TE

Permissible operating temperature range

0 up to 50 C

Storage temperature

25 C up + 70 C

Weight

m 0.15 kg

Note!
For details regarding the environmental simulation test covering EMC (electro-magnetic compatibility), climate and mechanical
loading see RE 30117-U (declaration regarding environmental compatibility).

UL

t2

17 Output stage

6 Power supply
7 Command value limiter
8 PID-controller
9 Fault recognision

t2 = Ramp time down

= Enable

16 Demodulator

5 Enable circuit

= Operational

17

17

1
x

15
Zx

13

u
i

32a Act. value


0 to 6 V

28c

19

Com. value
0 to + 6 V

12c
12a

18

20c

22c

4ac

2ac

See page 6 for an explanation regarding


the bridges (from X3) as well as the
location of the display and adjustment
elements

16

14
=

11

> 1 12

X1

Industrial Hydraulics Bosch Rexroth AG

19 Position transducer

18 Proportional valve

15 Position transducer driver

14 Oscillator

13 Clocked output stage

12 Over-current recognision

Gx = Actual value

t1 = Ramp time up

Gx

11 Summator controller

4 Threshold value switch

Gw

3 Ramp generator

1 Differential amplifier

UL

t1

t2

X8, X9

PID

Zx = Zero point actual value

X3

t1

Gw = Command value attentuator

2,5 A T

Zw

X4

2 Command value summator

10ac

6ac

UL

Zw = Zero point command value

0 V (L0)

UB = 24 V

Call-up voltage (UL)

8ac

9 V 14ac

u/i

X12X14

UL

VT-VRPA1-100

Operating
voltage

20a

+ 9 V 16ac
M0 18ac

Enable

Com.value 3
(differential input): 22a
0 + 10 V 24c
/ 0 to 20 mA
/ 4 to 20 mA
Ref. potential

Com.value 1: 0 to+ 9 V 26c


Com.value 2: 0 to + 6 V 24a

30c
External ramp 32c

Ramp off
28a
or
minimum ramp

X1

RE 30118/11.04

33
5/8

Block circuit diagram / connection allocation

01

34
6/8

Bosch Rexroth AG

Industrial Hydraulics

VT-VRPA1-100

RE 30118/11.04

Display / adjustment elements


Enable 1)
Permanently ON

X3

X4

Permanently OFF

Externally controlable

Zw
Gw

Ramp

Externally controlable

X3 X4
F1
2,5 A T
X1

t1
t2
X9 X8

t1
x

X14

X12 X13

Gx

t2
w

Zx

VRPA1-100

Command value (differential input)


LED display:
Operational (green)
Enable (yellow)
Potentiometer:
Zw Zero point command value
Gw Command value attenuator
t1
Ramp time up
t2
Ramp time down
Not adjustable via the front planel:
Zx Zero point actual value
Gx Actual value
Measurement sockets:
t1
Ramp time up
t2
Ramp time down
x
Actual value
w
Command value

Measurement zero

Input signal
0 to + 10 V

X14

X12

X9

X8

0 to 20 mA
4 to 20 mA

Ramp time
0.02 to 5 s

0.2 to 50 s

= Bridge fitted
= Bridge open

1)

When replacing amplifier types VT 5003, VT 5004 and


VT 5010, jumper X3 (enable) must be set to permanently
ON.

= Factory pre-set bridges

X13

35
RE 30118/11.04

Industrial Hydraulics Bosch Rexroth AG

VT-VRPA1-100

7/8

Unit dimensions (in mm)

t2
w

01
8

t1
x

89

t1
t2

100

3HE (128,4)

Zw
Gw

VRPA1-100

4TE (20)

2
7

165
182

Engineering / maintenance guidelines / additional information


The amplifier card must be configured to match the application; see display/adjustment elements on page 6!
The amplifier card may only be unplugged or plugged when switched off!
For the solenoid connection, plugs fitted with free-wheeling diodes or LED displays must not be used!
Measurements at the card may only be caried out with instruments Ri > 100 k!
Measuring zero (M0) is increased by + 9 V compared to the 0 V operating voltage and is not potentially separated,
i.e. 9 V controlled voltage 0 V operating voltage. Therefore do not connect measuring zero (M0) with the 0 V operating
voltage!
For switching the command values use relays with gold contancts (small voltages, small currents)!
For switching the card relay only use contacts with a load capacity of approx. 40 V, 50 mA!
When using an external control, the control voltage must only have a maximum residual ripple of 10 %!
Always screen command value lines; screen to be connected to the 0 V operating voltage on the card side,
leave other side open (danger of earth loops)!
Recommendation: Also screen solenoid lines!
For solenoid cables of up to 50 m length use cable type LiYCY 1.5 mm2.
For longer lengths please consult us!
The distance to antenna lines, radio sources and radar equipment must be at least 1 m!
Do not lay solenoid and signal lines near power lines!
Because of the loading current of the smoothing capacitor on the card, the pre-fuses must have slow blowing characteristics!
The connection of the inductive position transducer that is marked with the ground symbol must not be connected to ground!
(Precondition for the compatibility with amplifier types VT 5003, VT 5004 and VT 5010)
Attention: When using the differential input, both inputs must always be switched on or off simultaneously!
Note:

Electrical signals generated via control electronics (e.g. actual value) must not be
used for switching safety-relevant machine functions!
(Also see the European Standard Safety requirement for fluid power systems
and components Hydraulics, EN 982)

36
8/8

Bosch Rexroth AG

Industrial Hydraulics

VT-VRPA1-100

RE 30118/11.04

Preferred types
Type

Material number

VT-VRPA1-100-1X/V0/0

R901009038

VT-VRPA1-150-1X/V0/0

R901057058

VT-VRPA1-151-1X/V0/0

R901057060

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. Without their
consent it may not be reproduced or given to third parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.

37

RE 30117/07.05
Replaces: 02.03

Analogue Amplifiers

1/8

Type VT-VRPA1-50 to VT-VRPA1-52

Series 1X

H6197_d

Table of contents
Contents

Features
Page

Features

Ordering code

Functional description
Block circuit diagram / pin assignment
Technical data

2-3
4
5-6

Unit dimensions

Indicator / adjustment elements

Engineering / maintenance notes / supplementary information 8

Suitable for controlling pilot operated proportional flow control


valves (throttle valves) with electrical position feedback, types
FE (sizes 16 and 25) and FES (sizes 25 to 63)
In terms of plugs, compatible with amplifier types VT 5011,
VT 5012 and VT 5062 to VT 5066 (depending on valve type
and size)
Power supply unit with raised zero point
Command value signal inputs:
0 to +6 V; 0 to +9 V; 0 to +10 V
0 to 20 mA; 4 to 20 mA (jumpers)
Potentiometer adjustment for zero point and amplitude
attenuation on the front panel
Measuring sockets for ramp time
Enable input and ramp OFF input
Jumpers for changing over the maximum ramp time
0.02 s to 5 s or 0.2 s to 50 s
Jumpers for adjustment to valve type and size
Outputs for command value (0 to +6 V) and actual value
(0 to 6 V)
LED indicator lamp ready for operation
Reverse polarity protection

38
2/8

Bosch Rexroth AG

Hydraulics

VT-VRP1-50 to VT-VRP1-52

RE 30117/07.05

Ordering code
VT-VRPA1
Amplifier for proportional valves with electrical
position feedback, analogue, with 1 output stage

1X

*
Further details in clear text

1X =

Series 10 to 19
(10 to 19: unchanged technical data
and pin assignment)

Amplifier for proportional flow control valves (throttle valves):


Types FE 16, FE 25 and FES 25 (from series 2X each)
= 50
Types FES 32 and FES 40 (from series 3X each)
= 51
Types FES 50 and FES 63 (from series 3X each)
= 52
Suitable card holders:
Type VT 3002-2X/32, see RE 29928
Single card holder without power supply unit

When ordering spares for amplifiers VT 5011, VT 5012


and VT 5062 to VT 5066 for rack installation, a blind plate
4TE/3HE must be ordered separately.

Suitable power supply unit:

Material no.: R900021004

Type VT-NE30-1X, see RE 29929


Compact power supply unit 115/230 VAC 24 VDC, 70 VA
Further information:
VT-PPV-1X, see RE 29687

Functional description
Power supply unit
After the operating voltage was applied, the internal power
supply unit [6] generates a voltage of 9 V as against measuring zero (M0). This is raised by +9 V when measured against
load zero (L0). The voltages of +9 V and 9 V (9 V corresponds to L0) are applied to terminal strip X1 and can be used
externally (e.g. for a command value potentiometer). The max.
load carrying capacity is 25 mA.

When cutting the command value voltage in or out, care must


be taken that always both signal lines are disconnected from or
connected to the input. Before being passed on, all command
values are summated correctly in terms of amount and sign [2].
Offset voltages in the command value branch can be compensated for by means of potentiometer Zw.
External command value potentiometer (for 9V command
value input)

Readiness for operation


The amplifier card is ready for operation, when the following
conditions are fulfilled:
Operating voltage > 20 V
No asymmetry of the internal supply voltages
No cable break of position transducer cables
No short-circuit in solenoid cables
The green LED on the front panel lights up to signal readiness
for operation.
Command value
The command value voltage is provided either directly via the
regulated voltage of +9 V from the power supply unit [6] or via
an external command value potentiometer. The following is
valid for input command value 1: +9 V = +100 %, and for
input command value 2: +6 V = +100 %. The reference point
for command value inputs 1 and 2 is always M0 (18ac). Command value input 3 is a differential input [1] (0 to +10 V). It can
be configured as current input (0 to 20 mA or 4 to 20 mA) by
plugging jumpers. If the command value is provided by external
electronics with another reference potential, the differential
input must be used.

26c
5K

16ac

Input (+9 V
=100 %)
+9 V

18ac
M0

Ramp function
The ramp generator [3] connected downstream generates a
ramp-shaped output signal from a stepped input signal. The
time constants of the output signal (ramp times) can be
adjusted by means of potentiometers t1 (up ramp) and t2
(down ramp) that are accessible on the front panel. The maximum ramp time given refers to a command value step-change
of 100 % and can be approx. 5 s or 50 s depending on the
jumper configuration (X8, X9). If a command value step-change
of less than 100 % is applied to the input of the ramp generator [3], the ramp time shortens accordingly. The current ramp
time can be checked at measuring sockets t1 (up ramp)
and t2 (down ramp).
For details, see Technical data

39
RE 30117/07.05

Hydraulics Bosch Rexroth AG

VT-VRP1-50 to VT-VRP1-52

3/8

Functional description (continued)


Position acquisition

External time potentiometer


30c
32c

500K
Note:

When an external time potentiometer is used, the internal potentiometers for the ramp times must be set to maximum (voltages at measuring sockets t1 and t2 approx. 20 mV). The
maximum ramp time decreases, since the resistance of the external potentiometer is connected in parallel to that of the internal potentiometer (approx. 500 k). In this case, the ramp time
for the up and down ramp cannot be adjusted separately.
By applying a voltage > 10 V to the switching input ramp
OFF or by plugging jumper X4, the ramp time is set to its
minimum value (approx. 15 ms). The switching input then
becomes ineffective. In this case the minimum value is valid for
both directions.

The position transducer electronics consists of an oscillator


[14] with downstream driver [15] for controlling the inductive
position transducer and a demodulator [16] for evaluating the
position transducer signal (actual value). The oscillator frequency is approx. 2.5 kHz. The inductive position transducer must
be connected in a reactance circuit with central pick-off. The
position transducer electronics is matched in the factory. In the
case of very long or capacitive position transducer cables, delays resulting from the signal running time and line attenuation
may require a re-adjustment of the zero point (using potentiometer Zx) and the gain (using potentiometer Gx). The actual
value (corresponds to the position of the valve spool) can be
measured at the measuring socket.
Note:
The actual value signal is output inverted against the
command value. A travel of 100 % corresponds to 6 V at the
actual value measuring socket and connection 32a of terminal
strip X1.

Calculation of the ramp times


Jumper X9 plugged
(ramp time short)
tup =

tdown =

0,1
Ut1
0,1
Ut2

Jumper X8 plugged
(ramp time long)

(in s)

tup =

(in s)

tdown =

1
Ut1
1
Ut2

(in s)

(in s)

Enable input
A signal > 10 V at enable input 20a enables the output stage
and the I-controller (indicated by yellow LED on the front
panel). By plugging jumper X3 they are permanently enabled
independently of the signal at the enable input. The switching
input becomes ineffective.
[ ] = Cross-reference to block circuit diagram on page 4

Ut1; Ut2 voltage at measuring socket t1 or t2 (in V)


Limiter and position controller
The command value voltage is fed from the output of the ramp
generator [3] to potentiometer Gw, which is accessible on
the front panel and acts as attenuator. It can be used to adjust
the maximum flow through the valve. The downstream limiter
[7] limits the command value to +105 % or 5 % (e.g. in the
case of an excessively high command value voltage or maladjustment of the potentiometers for zero point Zw and basic
value Gw) in order to prevent the valve spool from hitting the
mechanical end positions. The output signal of the limiter [7] is
the position command value and is fed to the PID-controllers
[8] and, via output stage [17], to measuring socket w on the
front panel of the card as well as to connection 28c on terminal strip X1 (command value after ramp and limiter). A voltage
of +6 V at command value measuring socket w corresponds
to a command value of +100 %. The PID-controllers are optimised to the individual valves. Before the card is installed, the
plug-in jumpers X2 have to be plugged at the position provided for the valve type to be controlled (see also tags at the
back of the printed circuit board). The controllers compare the
position command values and actual position values; in the
case of a difference, a corresponding control variable is output. The downstream summator [11] adds to the control output
a square-wave voltage generated by the dither generator [10];
the resulting signal is passed on to the current output stage
[13], whose output signal controls the proportional solenoid of
the throttle valve.

Note!
A command value preselection of 0V does not mean orifice in
seated position. At an actual value of 0 V the orifice spool is
in a positive overlap position. A command value of 0 V results
in an actual value of 0 V. Depending on the pressure differential, a certain amount of leak-oil flows at any time. If no enable
signal is applied or the output stage is blocked due to a failure,
the orifice spool moves onto the seat and provides a leak-free
closure.
In the seated position, the measurable actual value is > +0.5 V
(depending on valve type)

01

X1

20a

= Ramp time up
= Ramp time down

= Enable

= Command value zero point


= Command value attenuator
= Actual value zero point
= Actual value
= Readiness for operation

10ac

1
2
3
4
5
6
7
8

2,5 A T

UL

X3

t1

t2

t2

X8, X9

Gw

Differential amplifier
Command value summator
Ramp generator
Trigger
Enable circuit
Power supply unit
Command value limiter
PID-controller

UL

t1

9
10
11
12
13
14
15
16

Gx

5 6

3 4

1 2

X2

Fault detector
Dither generator
Summator, controller
Overcurrent detector
Clocked output stage
Oscillator
Position transducer driver
Demodulator

PID

PID

PID

17

17

Zx

Output stage
Proportional valve
Position transducer

15

13

2
1

18

19

32a

Actual value
0 to 6 V

28c Command value


0 to +6 V

12a

12c

20c

22c

4ac

2ac

For explanations regarding jumpers (from


X2) as well as position of the indicator
and adjustment elements, see page 7

17
18
19

16

14
=

11

> 1 12

X1

VT-VRP1-50 to VT-VRP1-52

t1
t2

Zw
Gw
Zx
Gx

0 V (L0)

6ac

X4

UL

Hydraulics

Operating
voltage

UO = 24 V

Call-up voltage (UL) 8ac

16ac
+9 V
M0 18ac
9 V 14ac

Enable

Zw

UL

10

Bosch Rexroth AG

Command value 3
X12X14
(differential input): 22a
u/i
0 to +10 V / 0 to 20 mA / 24c
u
4 to 20 mA
1
Reference potential

26c
Command value 1: 0 to +9 V
Command value 2: 0 to +6 V 24a

30c
Ramp external 32c

Ramp off
or 28a
minimum ramp

4/8

40
RE 30117/07.05

Block circuit diagram / pin assignment

41
RE 30117/07.05

Hydraulics Bosch Rexroth AG

VT-VRP1-50 to VT-VRP1-52

5/8

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC +40 % 5 %

Operating range:
Upper limit value

UO(t)max 35 V

Lower limit value

UO(t)min 22 V

Power consumption

PS < 30 W

Current consumption

I < 1.3 A

Fuse

IF 2.5 A T

Inputs:
Command value 1

Ui 0 V to +9 V (reference potential is M0)

Command value 2

Ui 0 V to +6 V (reference potential is M0)

Command value 3 (differential input)

Ui 0 V to +10 V
or

Ii 0 mA to 20 mA (Ri = 100 )

or

Ii 4 mA to 20 mA (Ri = 100 )

Enable
active

UE > 10 V

not active

UE < 9 V

External ramp deactivation


without ramp

UR > 10 V

with ramp

UR < 9 V

Adjustment ranges:
Zero point Zw

5 % to max. +30 %

Command value attenuator Gw

0 % to 105 %

Ramp time up
short (jumper X9 plugged)
long (jumper X8 plugged)

tup 1 < 20 ms to 5 s 20 % (Ut1: 0.02 V


= ca. 5 s; 5 V ca. 20 ms)

tup 2 < 0.2 s to 50 s 20 % (Ut1: 0.02 V


= ca. 50 s; 5 V = ca. 0.2 s)

Ramp time down


short (jumper X9 plugged)
long (jumper X8 plugged)

tdown 1 < 20 ms to 5 s 20 % (Ut2: 0.02 V


= ca. 5 s; 5 V = ca. 20 ms)

tdown 2 < 0.2 s to 50 s 20 % (Ut2: 0.02 V


= ca. 50 s; 5 V = ca. 0.2 s)

Outputs:
Output stage
solenoid current / resistance
biasing current VT-VRPA1-50, VT-VRPA1-52
VT-VRPA1-51

Imax 1.2 A 10 % / R(20) = 12.7


IV 550 mA
IV 400 mA

clock-pulse frequency

f freely clocking (ca. 1.5 kHz)

superimposed dither frequency

f 300 Hz 10 %

Driver for inductive position transducer


oscillator frequency
Regulated voltage

f 2.5 kHz 10 %
U 9 V 1 % (with raised zero point); 25 mA externally loadable

Measuring sockets
command value w

Uw 0 V to +6 V (Ri = 1 k)

actual value x

Ux 0 V to 6 V (Ri = 1 k)

up ramp t1

Ut1 0.02 V to ca. 5 V (cf. adjustment ranges)

down ramp t2

Ut2 0.02 V to ca. 5 V (cf. adjustment ranges)

01

42
6/8

Bosch Rexroth AG

Hydraulics

VT-VRP1-50 to VT-VRP1-52

RE 30117/07.05

Technical data (for applications outside these parameters, please consult us!)
Type of connection

32-pin male connector, DIN 41612, form D

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side

3 TE

Permissible operating temperature range

0 to 50 C

Storage temperature range

25 C to +70 C

Weight

m 0.15 kg

Note!
For details regarding environment simulation test in the field of
EMC (electromagnetic compatibility), climate and mechanical stress,
see RE 30117-U (declaration on environmental compatibility).

Unit dimensions (Dimensions in mm)

t2
w

t1
x

89

t1
t2

100

3HE (128,4)

Zw
Gw

VRPA1-50

4TE (20)

2
7

165
182

43
RE 30117/07.05

7/8

Hydraulics Bosch Rexroth AG

VT-VRP1-50 to VT-VRP1-52

Indicator / adjustment elements


Enable 1)

X3

Ramp

X4

Permanent ON

Permanent OFF (min)

Ext. controllable

Ext. controllable

X2
1
3
5

2
4
6

Zw
Gw

X3 X4
F1
2,5 A T
X1

t1
t2
X9 X8

t1
x

t2
w

X14

X12 X13

Gx
Zx

VRPA1-50
Command value (Differential input)

LED indicator lamps:


Readiness for operation (green)
Enable (yellow)
Potentiometers:
Zw

Command value zero point

Gw

Command value attenuator

t1

Ramp time up

t2

Ramp time down

Cannot be adjusted from front panel:


Zx

Actual value zero point

Gx

Actual value

Measuring sockets:
t1

Ramp time up

t2

Ramp time down

Actual value

Command value

Measuring zero

1)

In the case of spares for amplifier types VT 5011 and VT 5012,


jumper X3 (enable) must be plugged to permanently ON.

Input signal

X14

X12

X13

0 to +10 V

0 to 20 mA

4 to 20 mA

Selection of valve type


Valve type

X2
1-2

3-4

5-6

FE16; series 2X

FE25; series 2X

FES25; series 2X und 3X

1-2

3-4

5-6

FES32; series 3X

FES40; series 3X

With VT-VRPA1-52

1-2

3-4

5-6

FES50; series 3X

FES63; series 3X

With VT-VRPA1-50

With VT-VRPA1-51

Ramp time

X9

X8

0,02 s to 5s

0,2 s to 50 s

Jumper plugged
Jumper open
Factory setting of jumpers

01

44
8/8

Bosch Rexroth AG

Hydraulics

VT-VRP1-50 to VT-VRP1-52

RE 30117/07.05

Engineering / maintenance notes / supplementary information


The amplifier card must be configured according to the relevant application; see Indicator / adjustment elements on page 6!
The amplifier card may only be plugged in or withdrawn when disconnected from the power supply!
Do not use connectors with free-wheeling diodes or LED lamps for connecting the solenoids!
Measurements on the cards may only be taken using instruments with Ri > 100 k!
The measuring zero (M0) is raised by +9 V as against the 0 V operating voltage and is not electrically isolated, i.e. 9 V
regulated voltage = 0V operating voltage. The measuring zero (M0) must , therefore, not be connected with the 0 V operating
voltage!
Use relays with gold-plated contracts for passing on command values (small voltages, small currents)!
Only use contacts with a loadability of approx. 40 V, 50 mA for switching relays!
In the case of external controlling, the control voltage may have a maximum residual ripple content of 10 %!
Command value cables must always be shielded; connect the shield to 0V operating voltage on the card side and leave the
other end open (risk of earth loops)!
Recommendation:

Also shield solenoid cables!


For solenoid cables of a length up to 50 m, use cable type LiYCY 1.5 mm2.
In the case of greater lengths, please consult us!

The distance to aerial lines, radio equipment and radar systems must be at least 1 m!
Do not lay solenoid and signal cables near power cables!
Due to the charging current of smoothing capacitors on the card, back-up fuses must be of the slow-blowing type!
The connection of the inductive position transducer identified with the ground symbol must not be connected to the ground!
(Precondition for the compatibility with amplifier types VT 5011, VT 5012 and VT 5062 to VT 5066)
Attention: When using the differential input, both inputs must always be switched on or off simultaneously!

Note:

Electrical signals processed by control electronics (e.g. actual value) must not be used for activating
safety-relevant machine functions! (See also European standard Safety requirements for fluid power systems
and components Hydraulics, EN 982)

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

45

Analogue amplifier card


for 4/3 proportional
directional valves of type 4WRE

RE 30119/07.05
Replaces: 06.03

1/10

Type VT-VRPA2-.-1X/

Series 1X

H6641

Table of contents
Contents

Features
Page

Features

Ordering code

Function

Block circuit diagram / pin assignment

4 and 5

Technical data

6 and 7

Indicator / adjustment elements

8 and 9

Unit dimensions

10

Engineering / maintenance notes / supplementary information 10

Suitable for controlling direct operated 4/3 proportional directional valves with electrical position feedback, type 4WRE,
sizes 6 und 10, component series 2X
Designed as printed circuit board in Euro-format
100 x 160 mm and suitable for installation in a rack
Command value inputs:
Differential input 10 V
Four callable command value inputs 10 V
Current input 4 to 20 mA
Inversion of the internal command value signal via 24V input or
by means of jumpers
Selection of ramp time through quadrant recognition (24V
input) or ramp time call-ups (24V inputs) (option T5)
Changeover of the ramp time range by means of jumpers
Characteristic curve correction by means of separately
adjustable jump heights and maximum values
Enable input
Output signal ready for operation
Measuring sockets that can be switched over (option T5)
Reverse polarity protection for voltage supply
Power supply unit with DC/DC converter without raised zero
point

46
2/10

Bosch Rexroth AG

Hydraulics

VT-VRPA2-.-1X/

RE 30119/07.05

Ordering code

VT-VRPA2

1X V0

*
Further details in clear text 2)

Analogue amplifier in Euro-card format


For controlling 4WRE 6-2X valves 1)
For controlling 4WRE 10-2X valves 1)

=1
=2

Series 10 to 19
(10 to 19: unchanged technical data and pin assignment)

1)

Note:
Suitable only for 4/3 proportional directional valves

2)

Additional functions e.g. output stage monitoring, actual


value monitoring or ramp-ready signal on enquiry

T1 =
T5 =
= 1X

Suitable card holders:


19 rack types VT 19101, VT 19102, VT 19103 and VT 19110
(see RE 29768)
Enclosed card holder type VT 12302 (see RE 30103) with use
of a blind plate 4TE/3HE (material no. R900021004)
Open card holder type VT 3002-2X/48 (see RE 29928)
Only for installation in control cabinet!
Suitable power supply unit:
Type VT-NE30-2X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 108 W
Test equipment:
Type VT-PPV-1X see RE 29687

With one ramp time


With five ramp times
Basic version

47
RE 30119/07.05

Hydraulics Bosch Rexroth AG

VT-VRPA2-.-1X/

3/10

Function
Power supply unit [1]

Enable function [8]

The amplifier card is provided with a power supply unit with


making-current limiter. It supplies all the internally required positive and negative voltages. The making-current limiter prevents
high making-current peaks caused by smoothing capacitors in
the current output stage.

The enable function enables the current output stages and


passes the internal command value signal on to the ramp generator. The enable signal is indicated by an LED on the front
panel. When the enable is cut in, the internal command value
changes (with any preselected command value) according to
the set ramp time. This ensures that a controlled valve does not
open abruptly.

Command value preselection


The internal command value signal is generated from the sum
(summation [6]) of the external command value signal applied
to differential input [2] and current input [3], called signal [4]
and zero point offset [5] (zero point potentiometer Zw).
The following is valid:
Normalized
value

Current
input

Differential Comm. value Direction


input
meas. socket of flow

100 %

4 mA

10 V

10 V

0%

12 mA

0V

0V

100 %

20 mA

10 V

10 V

0%

< 1 mA **

P to B,
A to T
P to A,
B to T

0V

**If the current input is not activated or in the case of a cable


break of the command value cable, the resulting internal
command value signal is 0 %.
There is no changeover between current and voltage inputs.
The inputs are permanently available (see terminal assignment).

Ramp generator [9]


The ramp generator limits the gradient of the control variable.
The downstream step functions and amplitude attenuators do
not extend or shorten the ramp time.
Jumper J2 can be used to set the ramp time to minimum
(< 2 ms) (ramp off).
External ramp time adjustment
The ramp time set internally can be extended using an external potentiometer. The setting can be checked with the help of
the measuring socket. In the case of a cable break, the internal
presetting will be used automatically.
Characteristic curve generator [11]
The adjustable characteristic curve generator can be used to
adjust the step-change height and maximum values separately
for positive and negative signals in accordance with the
hydraulic requirements. The actual curve shape through the
zero point is not step-like, but linear.
Amplitude limiter [12]

Command value call-ups [4]


Four command value signals, w1 to w4, can be called up.
External command value voltages (command values 1 to 4) are
fed forward either directly through regulated voltage outputs
+10 V and 10 V or via external potentiometers. If the
command value inputs are connected directly to the regulated
voltages, the command values can be adjusted using potentiometers w1 to w4. If external potentiometers are used, the
internal potentiometers act as attenuators or limiters.
Only one call-up is possible at a time. If several call-ups are
activated simultaneously, call-up 1 has lowest priority, call-up
4 highest priority.
The active call-up is signalled by a yellow LED on the front
panel.
Command value inversion [7]
The command value that was generated internally from input
signals, command value call-ups and the -zero point offset signal can be inverted with the help of an external signal or jumper
J1. The application of an external inversion signal is signalled
by an LED (1) on the front panel.

The internal command value is limited to approx. 110 % of the


nominal range.
Oscillator [14]
The oscillator generates the control signal for the inductive
position transducer.
Demodulator [15]
The demodulator generates the actual value signal of the
valve spool position from the position transducer signal.
100 % 10 V
Position controller [17]
The position controller is optimised to the individual valve.
Current output stage [18]
The current output stage generates the clocked solenoid current for the proportional valve. The solenoid current is limited to
2.5 A to 2.8 A per output. The current output stage outputs are
short-circuit-proof. In the case of an internal fault signal or
missing enable, the output stages are deactivated.
Fault detection [19]
The position transducer cable is monitored for cable break and
short-circuit on the primary side, and the output stages for
excessive current.
[ ] = Cross-reference to the block circuit diagram on page 4

01

0V

b18
z24
z26
z28

L0

w3

w2

w1

DC

J1 -1

ok

J4

S+

Gw-

t1

S-

t3

t2

J2, J3
t
t4

11

Gx

15

Zx

&
19

16

UL

18 Current output stage


19 Fault detection
15 Demodulator

13 Command value output


14 Oscillator

ok

-1

+1

17 Valve spool position controller

16 Actual value output

Fault recognition

Enable

12

14

ok

12 Amplitude limiter

11 Char. curve generator

+15V
+7,5 V
+5V
M0
5 V
7,5V
15 V

Gw+

6 Command value summator

DC 1

Zw 5

max t

Controller

z20

b28

b26

b30

b32

d22

d20

d32

z10

z14
z16

z12

z18

z6
z8
z2
z4

System ground

M0

Measuring signal
Ramp time

10 V / 25 mA

+10 V / 25 mA

Ready for operation

Reserved

Actual value

Reserved

Reserved
internal command value

VT-VRPA2-.-1X/

7 Command value inversion


3 Current input
8 Enable function
4 Comm. value selection logic 9 Ramp generator
5 Zero point adjustment

100 F

UL

Enable

1 Power supply unit


2 Differential input

w4

U
18

z22

d30

d26

Hydraulics

Operating 24 V
z32
voltage

z30

b10
d18

d2
1
d4
2
d6
3
d8
4

b2

b4

b6

b8

17

Solenoid b Solenoid a Inductive position transducer

Inversion
Enable

Command
value
call-ups

Comm. value 1

Comm. value 2

Comm. value 3

Comm. value 4

Comm. value 6
4-20 mA

b14
+
b16

b22
+
b24

d24
d28

UP/DOWN

13

Bosch Rexroth AG

Comm. value 5
10 V

Ramp time
external

+15 V

d10
d12
d14
d16

b12
b20

4/10

48
RE 30119/07.05

Block circuit diagram / pin assignment: VT-VRPA2-.-1X/V0/T1

b14
+
b16

b22
+
b24

d24
d28

0V

z30

b10
d18

Reserved

100 F

UL

Enable

DC 1

Zw 5

DC

J1 -1

6
ok

J4

S+

Gx

15

Zx

ABCD

20

&
19

16

0123456789ABCDE F

Measuring points

Fault recognition

Enable

12

20 Measuring point changeover

19 Fault recognition
14 Oscillator

UL

z20

b28

b26

b30

b32

d22

d20

d32

z10

z14
z16

z12

z18

z6
z8
z2
z4

z22

d30

d26

System ground

M0

Measuring signal

10 V / 25 mA

+10 V / 25 mA

Ready for operation

Reserved

Actual value

Reserved

Reserved
internal command value

Hydraulics Bosch Rexroth AG

15 Demodulator

18 Current output stage


13 Command value output

ok

-1

+1

U
18

17 Valve spool position controller

11

14

ok

Controller

17

12 Amplitude limiter

t
t4

16 Actual value output

S-

t3

t2

J2, J3

11 Char. curve generator

Gw-

t1

max t

+15V
+7,5 V
+5V
M0
5 V
7,5V
15 V

Gw+

10 Ramp time selection logic

w1

t5

5 Zero point adjustment

w2

t4

8 Enable function
9 Ramp generator

t3

3 Current input
4 Comm. value selection logic

L0

w3

t2

6 Command value summator


7 Command value inversion

w4

t1

10

4Q

EF 0

1 Power supply unit


2 Differential input

b18
z24
z26
z28

Operating 24 V
z32
voltage

Inversion
Enable

Command
value callups

d2
1
d4
2
d6
3
d8
4

Comm. value 1 b2

Comm. value 2 b4

Comm. value 3 b6

Comm. value 4 b8

Comm value 6
4-20 mA

Comm value 5
10 V

Ramp time
external

Ramp callups

d10
1
d12
2
d14
3
d16
4
+15 V

13
Solenoid b Solenoid a Inductive position transducer

34
12 5

b12
Reserved
Quadrant operation b20

VT-VRPA2-.-1X/

6789

RE 30119/07.05

49
5/10

Block circuit diagram / pin assignment: VT-VRPA2-.-1X/V0/T5

01

50
6/10

Bosch Rexroth AG

Hydraulics

VT-VRPA2-.-1X/

RE 30119/07.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC +40 % 20 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 18 V

Power consumption

PS < 24 VA

Current consumption

I <2A

Fuse

Is 2 A medium time lag, can be replaced

Inputs:
Analogue
Command values 1 to 4 (potentiometer inputs)

Ui 0 to 10 V; Ri > 100 k (reference is M0)

Command value 5 (differential input)

Ui 0 to 10 V; Ri > 50 k

Command value 6 (current input)


Ramp time external

Ii 4 to 20 mA; load Rl = 100


Ui 0 to +10 V; Ri = 10 k (internally raised to +15 V; reference is M0)

Digital
Command value call-ups

U 8.5 V to UO call-up activated; Ri > 100 k


U 0 to 6.5 V no call-up; Ri > 100 k

Ramp call-ups

U 8.5 V to UO call-up activated; Ri > 100 k


U 0 to 6.5 V no call-up; Ri > 100 k

Quadrant recognition

U 8.5 V to UO ON; Ri > 100 k


U 0 to 6.5 V OFF; Ri > 100 k

Command value inversion

U 8.5 V to UO ON; Ri > 100 k


U 0 to 6.5 V OFF; Ri > 100 k

Enable

U 8.5 V to UO ON; Ri > 100 k


U 0 to 6.5 V OFF; Ri > 100 k

Adjustment ranges:
Zero balancing (potentiometer Zw)

30 %

Command value (potentiometers w1 to w4)

0 to 110 %

Ramp times (potentiometers t1 to t5)

20 ms to 5 s; can be changed over, 0.2 to 50 s

Step-change height (potentiometers S+ and S)

0 % to 50 %

Amplitude attenuator (potentiometers G+ and G)

0 % to 110 % (valid for setting of step-change height to 0 %)

51
RE 30119/07.05

Hydraulics Bosch Rexroth AG

VT-VRPA2-.-1X/

7/10

Technical data (for applications outside these parameters, please consult us!)
Outputs:
Command value signal

U 10 V 2 %; Imax = 2 mA

Actual value signal

U 10 V 2 %; Imax = 2 mA

Measuring point signal (option 5)

U 10 V 2 %; Imax = 2 mA

Ready for operation

U > 16 V; 50 mA (in case of fault: U < 1 V; Ri = 10 k)

Regulated voltages

U 10 V 2 %; 25 mA; short-circuit-proof

Current output stages


Oscillator

I 0 to 2.5 A; short-circuit-proof; clocked ca. 5 kHz


U 5 VSS per output; 10 mA
F 5.6 kHz 10 %

Measuring sockets

U 10 V 2 %; Imax = 2 mA

Type of connection

48-pin male connector, DIN 41612, form F

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side

3 TE

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 C to +85 C

Weight

m 0.17 kg (net)

Note:
For details regarding environment simulation tests in the field of EMC (electromagnetic compatibility), climate and mechanical
stress, see RE 30119-U (declaration on environmental compatibility).

01

52
8/10

Bosch Rexroth AG

Hydraulics

VT-VRPA2-.-1X/

RE 30119/07.05

Indicator / adjustment elements


VT-VRPA2-.-1X/V0/T1
J3

J4

Ramp time

0.2 to 50 s

OFF
ON

0.02 to 5 s
-1

Step function

Gw+ S+ Gw- S-

No function!
Reserve

J6

J4

Do not change!
(Ramp time symmetry)

Zw
w1
w2
w3
w4

J3

J1

J2

J5

Zx
Gx

J7

w
t

VRPA2

Do not change!
(Internal reference voltage)
J2

LED lamps:
Ready for operation (green) Measuring sockets:
Measuring signal
x, w, t
Enable (yellow)
1 External inversion

No function!
Reserved for special functions

Ramp function

OFF
ON

Measuring zero

J1

Inversion

Inverting
Not inverting

Jumper plugged
Jumper open
Factory setting of jumpers

Potentiometers (some with LED lamps):


Zw Zero point balancing

Can be adjusted on the printed-circuit board:

w1

Command value 1

Gw+ Amplitude attenuator for positive command values

w2

Command value 2

Gw

Amplitude attenuator for negative command values

w3

Command value 3

S+

Step-change height for positive direction

w4

Command value 4

Step-change height for negative direction

Ramp time

If you change sealed potentiometer settings, the warranty


will become void!

53
RE 30119/07.05

Hydraulics Bosch Rexroth AG

VT-VRPA2-.-1X/

9/10

Indicator / adjustment elements


VT-VRPA2-.-1X/V0/T5
J3

J4

Ramp time

Step function

OFF
ON

0.2 to 50 s
0.02 to 5 s

No function!
Reserve
-1 4Q T

Gw+ S+ Gw- S-

F 01

23

789A

456

BC DE

J4

Do not change!
(Ramp time symmetry)

Zw
w1
w2
w3
w4
t1
t2
t3
t4
t5
v0
vF

w
v

J6

01
J3

J1

J2

J5

Zx
Gx
J7
Measuring
point selector
switch

VRPA2

Do not change!
(Internal reference voltage)
J2

No function!
Reserved for special functions

Ramp function

OFF
ON

J1

Inversion

Inverting
No inverting

Measuring sockets:

LED lamps:
Ready for operation (green)

x, w, v

Measuring signal

Enable (yellow)

Measuring zero

Jumper plugged

1 External inversion

Jumper open

4Q Quadrant recognition

Factory setting of jumpers

T Reserved

Potentiometers (some with LED lamps):


Zw Zero point balancing

Can be adjusted on the printed-circuit board:

w1 Command value 1

Gw+ Amplitude attenuator for positive command values

w2 Command value 2

Gw

Amplitude attenuator for negative command values

w3 Command value 3

S+

Step-change height for positive direction

w4 Command value 4

Step-change height for negative direction

t1

Ramp time 1

t2

Ramp time 2

t3

Ramp time 3

t4

Ramp time 4

t5

Ramp time 5

If you change sealed potentiometer settings,


the warranty will become void!

54
10/10

Bosch Rexroth AG

Hydraulics

VT-VRPA2-.-1X/

RE 30119/07.05

Unit dimensions (nominal dimensions in mm)

-1

89

100

3HE (128,4)

Zw
w1
w2
w3
w4

w
t

VRPA2

4TE (20)

2
7

165
182

Engineering / maintenance notes / supplementary information


For further information, see Product description and commissioning instructions VT-VRPA2-.-1X/ (RE 30119-B).

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

55
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 048/11.02

Electric amplifiers
Type VT-VRPA2
Series 1X

01
Type VT-VRPA2

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Additional information
Device dimensions

Features
Page
1
2
2
2
3
4
5
6

Suitable for actuating directly operated servo solenoid valves


(type 4WRP, series 1X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Ramp generator can be deactivated
Deadband compensation
Output stage with closed-loop control
Enabling input
Inputs and outputs (partially) short-circuit-proof
External ramp deactivation
Adjustment possibilities
Valve zero
Sensitivity
Ramp times
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Testing and service equipment
Test box type VT-PE-TB1, see RE 30 063
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRPA2

1/6

RE 30 048/11.02

56

Ordering data
VTHydraulic component
For valves with electrical
feedback

RTP =

=R

Valve type
Servo solenoid valve

=P
V0 =

Actuation
Analog

=A
1X =

Output stage
Two output stages per valve

=2

527 =
537 =

Option
Ramp function
manually adjustable
Customer version
Catalogue version
Series
Series 10 to 19
Serial numbers for types
NG 6
NG 10

Preferred types (available at short notice)


Material no.

Type VT-VRPA2

For valve types

0 811 405 119


0 811 405 120

VT-VRPA2-527-10/V0/RTP
VT-VRPA2-537-10/V0/RTP

4WRP 6 1X
4WRP 10 1X

Front panel

RE 30 048/11.02

2/6

VT-VRPA2

57

Block diagram with terminal assignment

01

VT-VRPA2

3/6

RE 30 048/11.02

58

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to b16/b18 and b2/b4

Smoothing capacitor, separately to


b28/b30 b2/b4
Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)
Signal source
Actual-value feedback
0 811 405 119
0 811 405 120
Output stage enable
Ramp OFF
Solenoid output

Length of amplifier to valve cables

Special features

Adjustment via trimming potentiometer

LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal,
Battery voltage 2140 V,
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/25 (NG 6)
3.7/50 (NG 10)
1.5 A
2.5 A
The current rating can rise at min. UB
and long cable length to control solenoid
35 W
60 W
0 10 V supply from b10, z8, z10, z12, z14/b14 cumulative
(Ri = 10 k )
Potentiometer 1 k , +10 V supply from b 32 (50 mA), 10 V from z22 (50 mA)
or external signal source
Oscil. b26
Meas. tap z28*
10.2 Veff / 7.8 kHz
0 10 V DC
10.2 Veff / 7.8 kHz
0 10 V DC
To z16, U = 8.5 40 V, Ri = 100 k, LED (green) on front panel lights up
To b20, U = 8.5 40 V
Output stage to solenoid
Signal to position sensor
Potentiometer power supply
Solenoid cable:
up to 20 m 1.5 mm2
20 to 50 m 2.5 mm2
Position transducer: max. 50 m at 100 pF/m
Supply and capacitor 1.5 mm2
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Ramps with quadrant recognition
Deadband compensation in valve centre position
Ramps can be deactivated
1. Zero NPA and NPB
2. Sensitivity QA and QB
3. Ramps for acceleration and deceleration t = 0.05 5 s
Green: Enable ON
Red: UB < UB min. (approx. 21 V)
Yellow: Ramp OFF
Yellow: Feedback signal open circuit
z 22: Open collector output to +UK
max. 100 mA; no fault: +UK

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12 separately to central ground (neutral point).
* Values for potentiometer in end position (cw) and for zero potentiometer in centre position.

RE 30 048/11.02

4/6

VT-VRPA2

59

Additional information
Information for using ramps
Ramp ON if b 20 is open.
Ramp OFF if b 20 is linked to b 22 or U = 8.5 ... 40 V at b 20.
Ramp OFF, Enable OFF or Open circuit interrupts a ramp in
progress. There is an abrupt transition to the final signal value.
Quadrant recognition A
Travel through the centre position leaves the direction of motion
of the valve spool unchanged but not that of the cylinder. In
order to ensure that the acceleration values for both directions
of motion remain the same when the valve crosses from one
quadrant to another, the ramp is switched over by the process of
quadrant recognition.

Deadband compensation in valve centre position B


The positive overlap of 20 % of the spool stroke is bypassed by
means of an electronic compensation circuit in the 15 % range
of the spool stroke.
Zero compensation
A low setpoint (UE = 0.3 ... 0.5 V) must be entered for zero compensation, in order to ensure exit from the deadband.

01
A

VT-VRPA2

5/6

RE 30 048/11.02

60

Device dimensions (in mm)

Connector DIN 41 612 F 32

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 048/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRPA2

61
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 047/11.02

Electric amplifiers
Type VT-VRPA2
Series 1X

01
Type VT-VRPA2

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Additional information
Device dimensions

Features
Page
1
2
2
2
3 and 4
5
6
6

Suitable for actuating directly operated servo solenoid valves


(type 4WRP, series 1X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Ramp generator can be deactivated
Deadband compensation
Output stage with closed-loop control
Enabling input
Adjustment possibilities
Valve zero
Sensitivity
Ramp times
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Inputs and outputs (partially) short-circuit-proof
External ramp deactivation
External voltage-controlled ramp adjustment via differential
inputs
Testing and service equipment
Test box type VT-PE-TB1, see RE 30 063
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRPA2

1/6

RE 30 047/11.02

62

Ordering data
VTHydraulic component
For valves with electrical
feedback

RTS =

=R

Valve type
Servo solenoid valve

=P
V0 =

Actuation
Analog

=A
1X =

Output stage
Two output stages per valve

=2

527 =
537 =

Option
Ramp function set
via signal
Customer version
Catalogue version
Series
Series 10 to 19
Serial numbers for types
NG 6
NG 10

Preferred types (available at short notice)


Material no.

Type VT-VRPA2

For valve types

0 811 405 137


0 811 405 138

VT-VRPA2-527-10/V0/RTS
VT-VRPA2-537-10/V0/RTS

4WRP 6 P-1X
4WRP 10 P-1X

Front panel

RE 30 047/11.02

2/6

VT-VRPA2

63

Block diagram with terminal assignment

01

VT-VRPA2

3/6

RE 30 047/11.02

64

Block diagram with terminal assignment of daughter card


Function range: Ramp generator
Internal/external input 0 ... + 10 V for the ramp time

RE 30 047/11.02

Logic signals
Ramp OFF
Ramp setpoints EXTERNAL
Ramp signal = 0 V

4/6

VT-VRPA2

65

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to b 16/ b 18 and b 2/b 4

Smoothing capacitor, separately to


b 28/b 30 b 2/b 4
Valve solenoid A/VA max.
Current rating

Solenoid output
b6b8/z2z4
Power consumption (typical)
Input signal (setpoint)
Signal source
Actual-value feedback
0 811 405 137
0 811 405 138
Output stage enable
Ramp internal/external
Ramp OFF
Length of amplifier to valve cables

Short-circuit-proof outputs

Special features

Adjustment via trimming potentiometer

LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal,
Battery voltage 2140 V,
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4700 F/63 V =, only required if UB ripple >10 %
2.7/25 (NG 6)
3.7/50 (NG 10)
1.5 A
2.5 A
The current rating can rise at min. UB
and long cable length to control solenoid
Square-wave voltage, pulse-modulated
Imax. = 2.7 A
Imax. = 3.7 A
35 W
60 W
0 10 V to either b 10, z 8, z 10, z 12, z 14/b 14 cumulative (Ri = 10 k )
Potentiometer 1 k, +10 V supply from b 32 (50 mA) 10 V from z 22 (50 mA)
or external signal source
Oscil. b 26
Meas. tap z 28*
10.2 Veff / 7.8 kHz
0 10 V DC
10.2 Veff / 7.8 kHz
0 10 V DC
To z 16, U = 8.5 40 V, Ri = 100 k, LED (green) on front panel lights up
To z 24 U = 8.5 40 V DC
External ramp setpoints
To b 20, U = 8.5 40 V
Solenoid cable:
up to 20 m 1.5 mm2
20 to 50 m 2.5 mm2
Position transducer: max. 50 m bei 100 pF/m
Supply and capacitor 1.5 mm2
Output stage to solenoid
Signal to position sensor
Potentiometer power supply
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Ramps with quadrant recognition
Deadband compensation in valve centre position
Ramps can be deactivated
Ramp setpoints can be input internally (pots.) or externally (voltage)
1. Zero NPA and NPB
2. Sensitivity QA and QB
3. Ramps for acceleration and deceleration t = 0.05 5 sec
4. Changeover of ramp adjustment range
Green: Enable ON
Green: External ramp
Yellow: Feedback signal open circuit
Yellow: Ramp OFF
Yellow: Q0 = 0 V
Red:
UB > UB min. (approx. 21 V)
Switching output
No fault +24 V (max. 100 mA)
Fault 0 V

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12 separately to central ground (neutral point).
* Values for potentiometer in end position (cw) and for zero potentiometer in centre position.

VT-VRPA2

5/6

RE 30 047/11.02

01

66

Additional information
Information for using ramps
1. Quadrant recognition
Quadrant recognition of the ramps takes place automatically
for positive and negative valve setpoints.
2. Changeover of INTERNAL/EXTERNAL input of ramp setpoints
Changeover is achieved by means of a voltage signal to z 24
in response to an external input
This renders the setting potentiometers ineffective
The EXTERNAL status is indicated by LED.
3. INTERNAL ramp adjustment
Set potentiometers
and
to the desired ramp profile
Precondition: No command to z 24 and/or to b 20.
4. EXTERNAL ramp adjustment
Voltage input to z 14 and z 20 (common reference point z 6)
Max. resolution: 75 mV
Precondition: Command to z 24 and no command to b 20.

5. Ramp time range


Two ramp time ranges can be set (changeover switch on
front panel). These apply to both internal and external
setpoint input.
6. RAMP OFF
Ramp is deactivated by a command to b 20
If a ramp is in progress, there is an abrupt transition to the
final signal value
The Ramp Off status is displayed by LED.
7. Signal UA = 0 V 0
When the ramp output voltage is UA = 0 V, the signal output
z 18 is switched to 24 V
This status is also displayed by an LED
If the ramp function is deactivated, the signal does not occur.

Device dimensions (in mm)

Connector DIN 41 612 F 32

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 047/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRPA2

67
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 040/11.02

Electric amplifiers
Type VT-VRRA1

Series 2X

01
Type VT-VRRA1

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Commissioning
Device dimensions

Features
Page
1
2
2
2
3
4
5
6

Suitable for actuating directly operated servo solenoid valves


with non-linear curve (type 4WRPH, series 2X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Area ratio adjustment of differential cylinders
Gain in weak signal range
Testing and service equipment
Test box type VT-PE-TB2, see RE 30 064
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRRA1

1/6

RE 30 040/11.02

68

Ordering data
VTHydraulic component
For valves with electrical
feedback

/
Option

=R

Valve type
Servo solenoid valve

K40-AGC= Servo solenoid valve with 40 % kink


K60-AGC= Servo solenoid valve with 60 % kink

=R
V0 =

Actuation
Analog

=A
2X =

Customer version
Catalogue version
Series
Series 20 to 29
Serial numbers for types
NG 6
NG 10

527 =
537 =

Preferred types (available at short notice)


Material no.

Type VT-VRRA1

For valve types

0 811 405 065


0 811 405 066
0 811 405 067

VT-VRRA1-527-20/V0/K40-AGC
VT-VRRA1-527-20/V0/K60-AGC
VT-VRRA1-537-20/V0/K40-AGC

4WRPH 6 P-2X
4WRPH 6 P-2X
4WRPH 10 P-2X

Front panel

see page 5

RE 30 040/11.02

2/6

VT-VRRA1

69

Block diagram with terminal assignment

Daughter card

01

VT-VRRA1

3/6

RE 30 040/11.02

70

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to z2 b2

Smoothing capacitor, separately to b 4, z 4


Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)

Signal source
Output stage enable
Position transducer Supply
Feedback signal
Feedback reference
Solenoid output
b6b8
Length of amplifier to valve
cables
Special features

Adjustment

LED displays

(100 x 160 x approx. 35) mm (B x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal
Battery voltage 2140 V
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/40 (NG 6)
3.7/60 (NG 10)
1.7 A
2.7 A
The current rating can rise at min. UB
and long cable length to control solenoid
37 W
55 W
b 20: 0 10 V
Difference amplifier
z 20: 0 10 V
(Ri = 100 k)
Potentiometer 10 k, 10 V supply from b 32, z 32 (10 mA)
or external signal source
To z 16, U = 8.5 40 V, Ri = 100 k, LED (green) on front panel lights up
b 30: 15 V
z 30: +15 V
b 22: 0 10 V, Ri = 20 k
b 24
Clocked current regulator
Imax. = 2.7 A
Imax. = 3.7 A
Solenoid cable:
up to 20 m 1.5 mm2
20 to 60 m 2.5 mm2
Position transducer: 4 x 0.5 mm2 (screened)
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
Linearization of non-linear flow curve
Zero via trimming potentiometer 5 %
Area ratio adjustment of differential cylinders
Gain in weak signal range
Green: Enable
Yellow: Feedback signal open circuit
Red: Undervoltage (UB too low)
z 22: Open collector output to +UK
max. 100 mA; no fault: +UK

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point).

RE 30 040/11.02

4/6

VT-VRRA1

71

Commissioning
1. The electric and hydraulic zero is set with the zero potentiometer.
In a closed control loop, during this process the contouring
error displayed by the CNC is compensated to 0.
2. Adjustment of differential cylinder
Adjust selector switch S on daughter card
Compensate direction-dependent contouring error at max.
feedrate with step switch K 3 (coarse adjustment) and with
potentiometer P 2 (fine adjustment)
3. Gain is optimized in the weak signal range with potentiometer P 1.

01

Selector switch S
Position depends upon pipework
and signal polarity

VT-VRRA1

5/6

RE 30 040/11.02

72

Device dimensions (in mm)

Connector DIN 41 612 F 32

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 040/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRRA1

73
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 046/11.02

Electric amplifiers
Type VT-VRRA1
Series 2X

01
Type VT-VRRA1

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Commissioning
Device dimensions

Features
Page
1
2
2
2
3
4
5
6

Suitable for actuating directly operated servo solenoid valves


with linear curve
(type 4WRPH, series 2X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Area ratio adjustment of differential cylinders
Gain in weak signal range
Testing and service equipment
Test box type VT-PE-TB2, see RE 30 064
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRRA1

1/6

RE 30 046/11.02

74

Ordering data
VTHydraulic component
For valves with electrical
feedback

KV-AGC =

=R

Valve type
Servo solenoid valve

Option
Function for variable kink
Weak signal gain
Area ratio adjustment

=R
Customer version
Catalogue version

V0 =
Actuation
Analog

=A
Series
Series 20 to 29

2X =

Serial numbers for types


NG 6
NG 10

527 =
537 =

Preferred types (available at short notice)


Material no.

Type VT-VRRA1

For valve types

0 811 405 069


0 811 405 070

VT-VRRA1-527-20/V0/KV-AGC
VT-VRRA1-537-20/V0/KV-AGC

4WRPH 6 P-2X
4WRPH 10 P-2X

Front panel

Item
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F

RE 30 046/11.02

2/6

Gain

K3


1:1
1.06 : 1
1.15 : 1
1.23 : 1
1.33 : 1
1.44 : 1
1.56 : 1
1.70 : 1
0.733
0.7
0.666
0.633
0.6
0.566
0.533
0.5

Surface area
ratio
1
0.97
0.934
0.9
0.867
0.834
0.8
0.766
1.86 : 1
2.04 : 1
2.23 : 1
2.50 : 1
2.77 : 1
3.12 : 1
3.52 : 1
4:1

VT-VRRA1

75

Block diagram with terminal assignment

01

VT-VRRA1

3/6

RE 30 046/11.02

76

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB an z2 b2

Smoothing capacitor, separately to b 4, z 4


Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)

Signal source
Output stage enable
Position transducer Supply
Feedback signal
Feedback reference
Solenoid output
b6b8
Length of amplifier to valve cables

Special features

Adjustment

LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal,
Battery voltage 2140 V,
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/40 (NG 6)
3.7/60 (NG 10)
1.7 A
2.7 A
The current rating can rise at min. UB
and long cable length to control solenoid
37 W
55 W
b 20: 0 10 V
Difference amplifier
z 20: 0 10 V
(Ri = 100 k )
Potentiometer 10 k , 10 V supply from b 32, z 32 (10 mA)
or external signal source
To z 16, U = 8.5 40 V, Ri = 100 k , LED (green) on front panel lights up
b 30: 15 V
z 30: +15 V
b 22: 0 10 V, Ri = 20 k
b 24
Clocked current regulator
Imax. = 2.7 A
Imax. = 3.7 A
Solenoid cable:
up to 20 m 1.5 mm2
20 to 60 m 2.5 mm2
Position transducer: 4 x 0.5 mm2 (screened)
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
Zero via trimming potentiometer 5 %
Area ratio adjustment of differential cylinders (K3)
Gain in weak signal range (P1)
Variable adjustment of circuit gain in advance range (K1)
Range setting of advance range (K2)
Green: Enable
Yellow: Feedback signal open circuit
Red: Undervoltage (UB zu too low)
z 22: Open collector output to +UK
max. 100 mA; no fault: +UK

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point).

RE 30 046/11.02

4/6

VT-VRRA1

77

Commissioning
1. The electric and hydraulic zero is set with the zero
potentiometer.
In a closed control loop, during this process the contouring
error displayed by the CNC is compensated to 0.
2. The range of minimal valve modulation is set with rotary
encoding switch K 2.
3. The gain is reduced with rotary encoding switch K 1, so that
the drive is stable in the range of minimal valve modulation.

4. If necessary, perform points 2. and 3. in several steps.


5. The different advance and return speeds (area ratio
adjustment of differential cylinders) are adjusted using
switch S and rotary encoding switch K 3 (see table for
polarity assignments).
6. The gain in the weak signal range is optimized by means
of P 1 (complete elimination of the contouring error).

01

Selector switch S
Position depends upon pipework
and signal polarity

VT-VRRA1

5/6

RE 30 046/11.02

78

Device dimensions (in mm)

Connector DIN 41 612 F 32

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 046/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRRA1

79
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 042/11.02

Electric amplifiers
Type VT-VRRA1
Series 1X

01
Typ VT-VRRA1

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Device dimensions

Features
Page
1
2
2
2
3
4
5

Suitable for actuating directly operated servo solenoid valves


with non-linear curve
(type 4WRPH...6, series 1X)
Analog amplifiers in Eurocard format for installation in
19 rack
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Testing and service equipment
Test box type VT-PE-TB1, see RE 30 063
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRRA1

1/6

RE 30 042/11.02

80

Ordering data
VTHydraulic component
For valves with electrical
feedback

/
Option
No code
Servo solenoid valve with
0 10 V actuation
RV = servo solenoid valve with
+ 3.5 6.5 9.5 V actuation

=R

Valve type
Servo solenoid valve

=R

Actuation
Analog

V0 =

Customer version
Catalogue version

=A
1X =

527 =

Series
Series 10 to 19
Servo solenoid valves with AC-Lvdt
Serial numbers for types
NG 6

Preferred types (available at short notice)


Material no.

Type VT-VRRA1

For valve types

0 811 405 123


0 811 405 148

VT-VRRA1-527-10/V0
VT-VRRA1-527-10/V0/RV

4WRPH 6 -1X
4WRPH 6 -1X

Front panel

* 0 811 405 148 without

RE 30 042/11.02

2/6

VT-VRRA1

81

Block diagram with terminal assignment

01

VT-VRRA1

3/6

RE 30 042/11.02

82

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to b 16/b 18 and b 2/b 4 (0 V)

Smoothing capacitor, separately


to b 28/b 30 b 2/b 4
Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)

0 811 405 148


0 811 405 123
Actual-value feedback

Output stage enable


Length of amplifier to valve cables

Short-circuit-proof outputs

Special features

LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal,
Battery voltage 2140 V,
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/25 (NG 6)
1.5 A
The current rating can rise at min. UB
and long cable length to control solenoid
Max. 35 VA
z 10 UE
Difference amplifier
z 12: 0 V
z8
b 10
UE = 6.5 3 V
UE = 0 10 V
Oscill. b 26: 10.4 V/8 kHz
Meas. tap z 28: 0 811 405 148
3.5 (6.5 V) 9.5 V
0 811 405 123
10 V (0 V) +10 V
To z 16, U = 8.5 40 V, Ri = 100 k , LED (green) on front panel lights up
Solenoid cable: up to 20 m 1.5 mm2
20 to 50 m 2.5 mm2
Feedback signal: max. 50 m at 100 pF/m
Output stage to solenoid
Signal to position sensor
Potentiometer power supply
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Rapid energizing and de-energizing for fast response times
Green: Enable
Yellow: Feedback signal open circuit
Red: UB < UBmin (21 V)
z 26: No fault +24 V/0.1 A
Fault: 0 V

Fault signal
Feedback signal open circuit
UB too low
Zero adjustment
Fixed
0 811 405 148
Via trimming potentiometer
0 811 405 123
Note
Connect power zero b 2 and control zero b 12 separately to central ground (neutral point).

RE 30 042/11.02

4/6

VT-VRRA1

83

Device dimensions (in mm)

Connector DIN 41 612 F 32

01

* Potentiometer only with 0 811 405 123

VT-VRRA1

5/6

RE 30 042/11.02

84

Notes

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 042/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRRA1

85
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 049/11.02

Electric amplifiers
Type VT-KRRA2
Series 2X

01
Type VT-KRRA2

List of contents
Contents
Features
Ordering data
Preferred types
Function
Block diagram
Technical data
Device dimensions
Double connector block

Features
Page
1
2
2
2
3
4
5
6

Suitable for actuating directly operated servo solenoid valves


(type 4WRPH, series 2X)
Double card for simultaneous operation of two NG 6/NG 10
servo solenoid valves
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-KRRA2

1/6

RE 30 049/11.02

86

Ordering data
VTHydraulic component
For valves with electrical
feedback

=R
2ch =

Valve type
Servo solenoid valve

=R
V0 =

Actuation
Analog

=A
2X =

Output stage
Two output stages

=2

527 =
537 =

Option
2-channel version
Customer version
Catalogue version
Series
Series 20 to 29
Serial numbers for types
NG 6
NG 10

Preferred types (available at short notice)


Material no.

Type VT-KRRA2

For valve types

0 811 405 083


0 811 405 082

VT-KRRA2-527-20/V0/2ch
VT-KRRA2-537-20/V0

4WRPH 6 L-2X
4WRPH 10 L-2X

Function
Applications
Synchronous running in presses and forming machines,
2-axis control systems in machine tools.
Plug connectors
2 x DIN 41 612, 32-pin for low-power signals (setpoint,
enable, etc.).
Screw-type plug connectors to the valve and for power supply
on front (ST 4, 5 and ST 9, 10) supplied.
Measurement taps
IC sockets on front for checking measurements and for inputting
signals.

RE 30 049/11.02

Displays
For open circuit, enable and undervoltage.
DC voltage regulation (DC/DC converter)
For supplying power to setpoint generators and position
transducers and internal common supply for both channels.
Guide frame
The double connector block 1 834 486 002 (see page 6) is
suitable for this P.C.B.

2/6

VT-KRRA2

87

Block diagram with terminal assignment

01

VT-KRRA2

3/6

RE 30 049/11.02

88

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector

Signals
Valve and supply

Ambient temperature
Power supply UB to
ST 4 and ST 9

Undervoltage UB < 18 V
Current rating
VT-KRRA2-527
of P.C.B.
VT-KRRA2-537
Power consumption
of solenoid
Smoothing capacitor
Setpoint to a20/c20
Signal source
Output stage enable
Position transducer
at ST 5 and ST 10

VT-KRRA2-527
VT-KRRA2-537

Supply
Supply
Signal

Reference voltage for


external electronics
Solenoid current
VT-KRRA2-527
VT-KRRA2-537
Open circuit
fault signal a22
Amplifier to valve cables

(233.4 x 160 x 30) mm (W x L x H), Europe double format


DIN 41 612, type D (ac)
Screw-type plug connector
on front
0 C ... +70 C
Storage temperature min. 20 C; max. +70 C
24 V DC nominal,
Battery voltage: 21 ... 40 V,
Rectified AC voltage Ueff = 21 ... 28 V
(single-phase, full-wave rectification)
LED (red) on front lights up
1.5 A max. per valve, the current rating can increase to 2.5 A at min.
UB and long cable length
2.7 A max. per valve, the current rating can increase to 3.5 A at min.
UB and long cable length
Max. 35 VA, nominal, per valve
Max. 50 VA, nominal, per valve
4,700 F/63 V DC required if UB > ripple 10 %
0 ... 10 V; Ri = 100 k (difference amplifier), overload capacity < 20 V
External electronic control system, reference 10 V from b 32, z 32
To a16 U = 8.5 ... 40 V; Ri = 100 k, LED (green) on front lights up
Terminal 4: 15 V/200 mA, short-circuit-proof
Terminal 3: +15 V/200 mA, short-circuit-proof
Terminal 1: 0 ... 10 V; RL 10 k
c32: 10 V/10 mA, short-circuit-proof
a32: +10 V/10 mA, short-circuit-proof
Max. 2.9 A
Max. 3.7 A
Fault: 0 V, no fault: 24 V, max. 100 mA
: LED (yellow) on front lights up
Solenoid cable:
0 ... 20 mm 1.5 mm2
0 ... 50 mm 2.5 mm2
Position transducer: 4 x 0.5 mm2 (screened)

Note
Power zero and control zero c14/c12 must be bridged. If their distance to the power supply is < 1 m, connect directly to DIN plug at c2/c4.
Where greater distances are involved, connect control system separately to ground. Connect power supply to connectors ST 4 and ST 9.
Adjustment
Zero adjustment via trimming potentiometer.

RE 30 049/11.02

4/6

VT-KRRA2

89

Commissioning

01

VT-KRRA2

5/6

RE 30 049/11.02

90

Double connector block


DIN 41 612-D32 (ac)

Screw terminals

Application
For P.C.B.s in Europe double format,
with 2 x connector strips
Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 049/11.02

[kg]
0.5

Material no.
1 834 486 002

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-KRRA2

91
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 045/11.02

Electric amplifiers
Type VT-VRRA1
Series 2X

01
Type VT-VRRA1

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Device dimensions

Features
Page
1
2
2
2
3
4
5

Suitable for actuating pilot operated servo solenoid valves


(type 4WRL, series 3X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Testing and service equipment
Test box type VT-PE-TB2, see RE 30 064
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRRA1

1/6

RE 30 045/11.02

92

Ordering data
VTHydraulic component
For valves with electrical
feedback

2STV =

=R

Valve type
Servo solenoid valve

=R

Actuation
Analog

V0 =

2X =

=A
527 =

Option
Pilot operated
servo solenoid valve
Customer version
Catalogue version
Series
Series 20 to 29
Serial numbers for types
NG 6

Preferred types (available at short notice)


Material no.

Type VT-VRRA1

For valve types

0 811 405 063

VT-VRRA1-527-20/V0/2STV

4WRL M-3X

Front panel

RE 30 045/11.02

2/6

VT-VRRA1

93

Block diagram with terminal assignment

01

VT-VRRA1

3/6

RE 30 045/11.02

94

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to z2 b2

Smoothing capacitor, separately to b 4, z 4


Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)

Signal source
Output stage enable
Position transducer Supply
Pilot stage
Main stage

Feedback signal
Feedback reference
Feedback signal
Feedback reference

Solenoid output
b6b8
Length of amplifier to valve cables

Special features

Adjustment
LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.20 kg
24 V DC nominal
Battery voltage 2140 V
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/40 (NG 6)
1.5 A
The current rating can rise at min. UB
and long cable length to control solenoid
37 W
b 20: 0 10 V
Difference amplifier
z 20: 0 10 V
(mi = 100 k)
Potentiometer 10 k, 10 V supply from b 32, z 32 (10 mA)
or external signal source
To z 16, U = 8.5 40 V, Ri = 100 k, LED (green) on front panel lights up
b 30: 15 V
z 30: +15 V
b 22: 0 10 V, Ri = 20 k
b 24
b 26: 0 10 V, Ri > 20 k
b 28
Clocked current regulator
Imax. = 2.7 A
Solenoid cable:
up to 20 m 1.5 mm2
20 to 60 m 2.5 mm2
Position transducer: 4 x 0.5 mm2 (screened)
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
Zero via trimming potentiometer 5 %
Green: Enable
Yellow: Feedback signal open circuit
Red:
Undervoltage (UB too low)
z 22: Open collector output to +UK
max. 100 mA; no fault: +UK

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point).

RE 30 045/11.02

4/6

VT-VRRA1

95

Device dimensions (in mm)

Connector DIN 41 612 F 32

01

VT-VRRA1

5/6

RE 30 045/11.02

96

Notes

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 045/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRRA1

97
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 043/11.02

Electric amplifiers
Type VT-VRRA1
Series 2X

01
Type VT-VRRA1

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Commissioning
Device dimensions

Features
Page
1
2
2
2
3
4
5
6

Suitable for actuating pilot operated servo solenoid


valves with non-linear curve
(type 4WRL...P, series 3X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Area ratio adjustment of differential cylinders
Gain in weak signal range
Testing and service equipment
Test box type VT-PE-TB2, see RE 30 064
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRRA1

1/6

RE 30 043/11.02

98

Ordering data
VTHydraulic component
For valves with electrical
feedback

/
Option
K40-AGC-2STV=
Pilot operated
servo solenoid valve with 40 % kink

=R

Valve type
Servo solenoid valve

=R
V0 =

Actuation
Analog

=A
2X =

Customer version
Catalogue version
Series
Series 20 to 29
Serial numbers for types
NG 6 pilot valve

527 =

Preferred types (available at short notice)


Material no.

Type VT-VRRA1

For valve types

0 811 405 068

VT-VRRA1-527-20/V0/K40-AGC-2STV

4WRL P-3X

Front panel

see page 5

RE 30 043/11.02

2/6

VT-VRRA1

99

Block diagram with terminal assignment

Daughter card

01

VT-VRRA1

3/6

RE 30 043/11.02

100

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to z2 b2

Smoothing capacitor, separately to b 4, z 4


Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)

Signal source
Output stage enable
Position transducer Supply
Pilot stage
Main stage

Feedback signal
Feedback reference
Feedback signal
Feedback reference

Solenoid output
b6b8
Length of amplifier to valve cables

Special features

Adjustment

LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal,
Battery voltage 2140 V,
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/40 (NG 6)
1.7 A
The current rating can rise at min. UB
and long cable length to control solenoid
37 W
b 20: 0 10 V
Difference amplifier
z 20: 0 10 V
(Ri = 100 k )
Potentiometer 10 k , 10 V supply from b 32, z 32 (10 mA)
or external signal source
To z 16, U = 8.5 40 V, Ri = 100 k , LED (green) on front panel lights up
b 30: 15 V
z 30: +15 V
b 22: 0 10 V, Ri = 20 k
b 24
b 26: 0 10 V, Ri = 20 k
b 28
Clocked current regulator
Imax. = 2.7 A
Solenoid cable:
up to 20 m 1.5 mm2
20 to 60 m 2.5 mm2
Position transducer: 4 x 0.5 mm2 (screened)
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
Linearization of non-linear flow curve
Zero via trimming potentiometer 5 %
Area ratio adjustment of differential cylinders
Gain in weak signal range
Green: Enable
Yellow: Feedback signal open circuit
Red: Undervoltage (UB too low)
z 22: Open collector output to +UK
max. 100 mA; no fault: +UK

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point).

RE 30 043/11.02

4/6

VT-VRRA1

101

Commissioning
1. The electric and hydraulic zero is set with the zero potentiometer.
In a closed control loop, during this process the contouring
error displayed by the CNC is compensated to 0.
2. Adjustment of differential cylinder
Adjust selector switch S on daughter card
Compensate direction-dependent contouring error at
max. feedrate with step switch K 3 (coarse adjustment)
and with potentiometer P 2 (fine adjustment)
3. Gain is optimized in the weak signal range with potentiometer P 1.

01

Selector switch S
Position depends upon pipework
and signal polarity

VT-VRRA1

5/6

RE 30 043/11.02

102

Device dimensions (in mm)

Connector DIN 41 612 F 32

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 043/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRRA1

103
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 044/11.02

Electric amplifiers
Type VT-VRPA1
Series 2X

01
Type VT-VRPA1

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Device dimensions

Features
Page
1
2
2
2
3 and 4
5
6

Suitable for actuating pilot operated servo solenoid


valves (type 4WRL, series 3X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Ramp function
External voltage-controlled ramp adjustment via
differential inputs
Ramp function can be deactivated
Testing and service equipment
Test box type VT-PE-TB2, see RE 30 064
Test adapter type VT-PA-3, see RE 30 070

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRPA1

1/6

RE 30 044/11.02

104

Ordering data
VTHydraulic component
For valves with electrical
feedback

RTS-2STV =

=R

Valve type
4WRL...M-3X

V0 =

=P

Actuation
Analog

2X =

=A
527 =

Option
Pilot operated
servo solenoid valve
Customer version
Catalogue version
Series
Series 20 to 29

Serial numbers for types


NG 6 pilot valve

Preferred types (available at short notice)


Material no.

Type VT-VRPA1

For valve types

0 811 405 073

VT-VRPA1-527-20/V0/RTS-2STV

4WRL M-3X

Front panel

RE 30 044/11.02

2/6

VT-VRPA1

105

Block diagram with terminal assignment


Functional diagram of ramp control, see page 4

01

VT-VRPA1

3/6

RE 30 044/11.02

Functions of the ramp daughter card


Three setpoint inputs
UEI differential input
(b 20 = 0 10 V z 20 = 0 V)
UEII relative to control zero (z 10)

UEIII cumulative effect


(z 12)
Choice of internal and external ramp time adjustment via
control input UText. (z 6)
LED display on front panel
Ramp rise time can be adjusted via switch on front panel to
T 0.1 3 s or
T 0.3 10 s
Ramp function activated/deactivated via Ramp off control
input (z 14)
LED display on front panel indicates operating mode

Internal ramp time adjustment via potentiometer on front panel


Accelerate Decelerate
External ramp time adjustment via voltage-controlled differential
inputs UT
Accelerate (b 16) Decelerate (b 18)
Signal output ramp completed at UE = 0 (z 18; open collector
output to +UA)
LED display on front panel
Adjustment: Sensitivity
Qa/Qb limitations in the range 100 50 % Qmax.
Automatic quadrant recognition on transition of valve from one
quadrant to another therefore only one setting potentiometer
or one control voltage for each ramp time input for acceleration
and deceleration.

Block diagram of ramp function


106

RE 30 044/11.02

4/6

VT-VRPA1

107

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to z2 b2

Smoothing capacitor, separately to b 4, z 4


Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)

Signal source
Output stage enable
Position transducer Supply
Pilot stage
Main stage

Feedback signal
Feedback reference
Feedback signal
Feedback reference

Solenoid output
b6b8
Length of amplifier to
valve cables
Special features

Adjustment
LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal
Battery voltage 2140 V
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/40 (NG 6)
1.5 A
The current rating can rise at min. UB
and long cable length to control solenoid
37 W
b 20: 0 10 V
Difference amplifier
z 20: 0 10 V
(Ri = 100 k)
Potentiometer 10 k, 10 V supply from b 32, z 32 (10 mA)
or external signal sourc
To z 16, U = 8.5 40 V, Ri = 100 k, LED (green) on front panel lights up
b 30: 15 V
z 30: +15 V
b 22: 0 10 V, Ri = 20 k
b 24
b 26: 0 10 V, RL > 10 k
b 28
Clocked current regula
Imax. = 2.7 A
Solenoid cable:
up to 20 m 1.5 mm2
20 to 60 m 2.5 mm2
Position transducer: 4 x 0.5 mm2 (screened)
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
Zero via trimming potentiometer 5 %
Green: Enable
Yellow: Feedback signal open circuit
Red: Undervoltage (UB too low)
z 22: Open collector output +UK
max. 100 mA; no fault: +UK

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point).
Information for setting ramps
1. Before the Accelerate/Decelerate ramps can be set,
Q = 0 and Qmax. must be compensated.
During this process, the ramp function can be either on or off.

3. Zero compensation: A low setpoint (UE = 0.3 ... 0.5 V) must


be entered for zero compensation, in order to ensure exit from
the deadband.

2. Set Q 0 at 0 V = UE.
Set Qmax. at + 10 V = UE.

4. You can now set the desired ramp profile by changing the
setpoint 0 + UE and + UE 0
Precondition: no command to z14.

VT-VRPA1

5/6

RE 30 044/11.02

01

108

Device dimensions (in mm)

Connector DIN 41 612 F 32

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 044/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRPA1

109
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 041/11.03
Replaces: 11.02

Electric amplifier
Types VT-VRRA1 and VT-VRPA1
Series 2X

01
Type VT-VRRA1

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Device dimensions

Features
Page
1
2
2
2
3
4
5

Suitable for actuating directly operated servo solenoid valves


with linear curve
(type 4WRPH...L, series 2X, type 5WRP10...L, series 2X)
Analog amplifiers in Eurocard format for installation
in 19 rack
Output stage with closed-loop control
Enabling input
Short-circuit-proof outputs
Adjustment possibilities: valve zero
Open-circuit detection for feedback signal cable
Closed-loop position control with PID action
Testing and service equipment
Test box type VT-PE-TB2, see RE 30 064
Test adapter type VT-PA-3, see RE 30 070

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-VRRA1; VT-VRPA1

1/6

RE 30 041/11.03

110

Ordering data
VTHydraulic component
For valves with electrical
feedback

=R

Valve type
p/Q valve
Servo solenoid valve

V0 =

=P
=R

Actuation
Analog

2X =

=A

527 =
537 =

Customer version
Catalogue version

Series
Series 20 to 29
Serial numbers for types
NG 6
NG 10

Preferred types (available at short notice)


Material no.

Type VT-VR.A1

For valve types

0 811 405 060


0 811 405 061
0 811 405 062

VT-VRRA1-527-20/V0
VT-VRRA1-537-20/V0
VT-VRPA1-537-10/V0

4WRPH 6 L-2X
4WRPH 10 L-2X
5WRP 10 L-2X

Front panel

RE 30 041/11.03

2/6

VT-VRRA1; VT-VRPA1

111

Block diagram with terminal assignment

01

VT-VRRA1; VT-VRPA1

3/6

RE 30 041/11.03

112

Technical data (For device applications beyond the stated values, please consult us!)
P.C.B. format
Plug connector
Ambient temperature
Weight m
Power supply
UB to z2 b2

Smoothing capacitor, separately to b 4, z 4


Valve solenoid A/VA max.
Current rating

Power consumption (typical)


Input signal (setpoint)

Signal source
Output stage enable
Position transducer Supply
Feedback signal
Feedback reference
Solenoid output
b6b8
Length of amplifier to valve cables

Special features

Adjustment
LED displays

(100 x 160 x approx. 35) mm (W x L x H)


Europe format with front panel (7 modular spacings)
DIN 41 612 F 32
0 C +70 C, storage temperature min. 20 C; max. +70 C
0.25 kg
24 V DC nominal
Battery voltage 2140 V
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)
4,700 F/63 V DC, only required if UB ripple >10 %
2.7/40 (NG 6)
3.7/60 (NG 10)
1.7 A
2.7 A
The current rating can rise at min. UB
and long cable length to control solenoid
37 W
55 W
b 20: 0 10 V
Difference amplifier
z 20: 0 10 V
(Ri = 100 k)
Potentiometer 10 k, 10 V supply from b 32, z 32 (10 mA)
or external signal source
To z 16, U = 8.5 40 V, Ri = 100 k, LED (green) on front panel lights up
b 30: 15 V
z 30: +15 V
b 22: 0 10 V, Ri = 20 k
b 24
Clocked current regulator
Imax. = 2.7 A
Imax. = 3.7 A
Solenoid cable:
up to 20 m 1.5 mm2
20 to 60 m 2.5 mm2
Position transducer: 4 x 0.5 mm2 (screened)
Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
Zero via trimming potentiometer 5 %
Green: Enable
Yellow: Feedback signal open circuit
Red: Undervoltage (UB zu too low)
z 22: Open collector output to +UK
max. 100 mA; no fault: +UK

Fault signal
Feedback signal open circuit
UB too low
15 V stabilization
Note
Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point).

RE 30 041/11.03

4/6

VT-VRRA1; VT-VRPA1

113

Device dimensions (in mm)

Connector DIN 41612 F 32

01

VT-VRRA1; VT-VRPA1

5/6

RE 30 041/11.03

114

Notes

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 041/11.03

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-VRRA1; VT-VRPA1

115

RE 30109/07.05

Electric amplifiers
for proportional valves

1/6

Type VT-VSPA1

Unit series 1X

List of contents

Features

Features

Analog amplifier in Europe card format for installation


in 19 subrack

Ordering data

Differential input for setpoint voltage 0...+10 V

Preferred types

Ramp generator with separate adjustment for up and down

Front panel

Zero potentiometer

Circuit diagram

Closed-loop-controlled output stage

Technical data

Unit dimensions

LED display:
Voltage supply
On standby
Ramp Off
Solenoid current IM = 0

Contents

Page

Testing and service equipment


Test box type VT-PE-TB1, see RE 30063
Test adapter type VT-PA-3, see RE 30070

116
2/6

Bosch Rexroth AG

Hydraulics

VT-VSPA1

RE 30109/07.05

Ordering data

VT

Hydraulic component
For valves without electrical feedback
Valve type
Proportional valve
Actuation
Analog

1X V0

RTP =
=S

=P

V0 =

=A

Output stages
1 output stage

1X =

=1

508 =
525 =

Preferred types

Type

Material Number

For valve types

VTVSPA152510/V0/RTP

0 811 405 079

see valve group A

VTVSPA150810/V0/RTP

0 811 405 081

see valve group B

Valve group A

Valve group B

DBETX...25

DBETX...8

DBE6X...25

DBE6X...8

DRE6X...25

DRE6X...8

DBE10Z...25

DBE10Z...8

DRE10Z...25

DRE10Z...8

2FREX6
2FREX10
3FREX6
3FREX10
4WRBA..EA

RTP
Optional extras
Ramp adjustment
via potentiometer
Customer version
Catalog version
Unit series
Unit series 10 to 19
Serial numbers for types
0.8 A solenoid
2.5 A solenoid

117
RE 30109/07.05

VT-VSPA1

Hydraulics Bosch Rexroth AG

3/6

Front panel

01

118
4/6

Bosch Rexroth AG

Hydraulics

Circuit diagram with pin assignment

VT-VSPA1

RE 30109/07.05

119
RE 30109/07.05

Hydraulics Bosch Rexroth AG

VT-VSPA1

5/6

Technical data
Specifications
P.C.B. format
Plug connector
Ambient temperature

mm (100 x 160 x approx. 35)/(W x L x H) Europe card format with front panel
with 7 modular spacings
Plug DIN 41612F32
C 0...+70, storage temperature min. 20; max. +70

Power supply

24 V DC nominal battery voltage 21...40 V, rectified AC voltage


Ueff = 21...28 V (single-phase, full-wave rectification)

Current rating

0 811 405 079 max. 1.5 A (NG6)/max. 2.5 A (NG10)


0 811 405 081 max. 1.25 A

Power consumption

0 811 405 079 max. 35 VA (NG6)/max. 60 VA (NG10)


0 811 405 081 max. 30 VA

Setpoint potentiometer

RL 1 k
Supply: b/z 32, +10 V/20 mA

Input signals

b10: +10 V
z10: +10 V
z16: +10 V
z18: Diff. 0 V

Differential
} input

External ramp shut-off

b20: 6...40 V= (nom. 10 V DC)

Ramp monitor signal

z20: 0...10 V

Cable lengths and cross-sections

Solenoid: < 20 m 1.5 mm2


Solenoid: 20...50 m 2.5 mm2

Special features

Short-circuit-proof inputs and outputs


Clocked output stage
Rapid energizing for fast response times

LED displays

Yellow:
Yellow:
Green:
Red:

Valve response time

50 ms with 100 % signal change

Valve hysteresis
Ramp times
Adjustment possibilities

ramp OFF
solenoid current IM = 0
UB ON
UB < UB min

% <4
s 0.05...5
Valve zero, sensitivity, ramp times, dither amplitude

Caution!
Power zero b2 and control zero b12 must be jumpered.
If removing power pack, < 1 m directly to DIN plug.
If removing > 1 m route control zero separately to ground.
Notes for calibrating the P.C.B.s
Zero:
A setpoint UE 300 mV is set as default for calibration.
Sensitivity (max.): A setpoint UE = 10 V is set as default for calibration.
Notes on the use of ramps
Ramp UP (accelerate) and ramp DOWN (decelerate) are each set
by a trimming potentiometer.
Ramp ON, if b20 open. Ramp OFF, if b20 U > 6 V, e.g. 10 V from b22.
Ramp OFF interrupts a ramp in progress.
There is an abrupt transition to the final signal value.

01

120
6/6

Bosch Rexroth AG

Hydraulics

VT-VSPA1

RE 30109/07.05

Unit dimensions (nominal dimensions in mm)

Plug to DIN 41612F32

Amplitude
Dither

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not release
the user from the obligation of own judgement and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

121

RE 30111/09.05
Replaces: 02.03

Electrical amplifiers

1/12

Type VT-VSPA1-1 and VT-VSPA1K-1

Component series 1X

H5897_d

Table of contents
Contents

Features
Page

Features

Ordering code

Functional description

2 and 3

Suitable for controlling all direct and pilot operated proportional pressure control valves without electrical position feedback
and only one solenoid as actuator that are available at the time
of publication of this data sheet

Block circuit diagram / pin assignment VT-VSPA1-1

Differential input, can be switched between voltage and current input

Block circuit diagram / pin assignment VT-VSPA1K-1

Additional command value input, 0 to +9 V

Technical data

Ramp generator, can be adjusted separately for up and down ramps

Output characteristic curves

Clocked output stage

Indicator / adjustment elements

8 and 9

Meaning of DIL switches

10

Unit dimensions

11

Engineering / maintenance notes / supplementary information 11


Troubleshooting

12

Signal "ready for operation" (VT-VSPA1K-1 only with LED


indicator lamp)
Reverse polarity protection for voltage supply
Cable break detection of current input 4 to 20 mA
Short-circuit protection of solenoid cable
Cable break detection of solenoid cable
Suitable card holders for VT-VSPA1-1:
Type VT 3002-2X/32, see RE 29928
Single card holder without power supply unit
Suitable power supply unit:
Type VT-NE30-1X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 108 W

122
2/12

Bosch Rexroth AG

Hydraulics

VT-VSPA1-1 and VT-VSPA1K-1

RE 30111/09.05

Ordering code

VT-VSPA1
Amplifiers for controlled proportional pressure
control valves, analogue, with one solenoid

1 1X

*
Further details in clear text

1X =

With 32-pin male connector and front panel


With 16-pin terminal strip; without front panel

= No code
=K

Component series 10 to 19
(10 to 19: unchanged technical data and pin
assignment)

For substitutes for amplifier types VT 2000 (up to


component series 4X), VT 2010, VT 2013 or VT 2023
for rack installation, blind plate 4TE/3HE must be ordered separately. Material no. R900021004

Functional description
The command value voltage is applied to command value input
1 either directly or via an external command value potentiometer
with the help of the regulated + 9V voltage from the power supply
unit [14].
The following is valid for this input: +9 V

+100 % 1).

External command value feedforward

5K

12(ac)

Input 1

10(ac)

+9 V

14(ac)

M0

Before being passed on, both command values are summated


[2] and then fed to a potentiometer [3] that is accessible on
the front panel and acts as attenuator and limits the maximum
command value.

18(ac)
Note:
When an external command value potentiometer is used, internal potentiometer "Gw" [3] must be set to maximum or the
required maximum pressure.
Internal command value feedforward
12(ac)

Input 1

10(ac)

+9 V

The following is valid for type VT-VSPA1K-1: The up and down


ramp times can be set collectively to their minimum value (approx. 30 ms) with the help of the external contact ramp OFF.

28(ac)

u (i)

0 to 20 mA
0V reference potential

30(ac)

The downstream ramp generator [4] generates a ramp-shaped


output signal from a stepped input signal. The time constant
of this signal can be adjusted separately for up and down
ramps with the help of two potentiometers. The specied ramp
time refers to a command value step-change of 100% and can
be approx. 1 s or 5 s, depending on the setting of a DIL switch 2).
If a command value step-change of less than 100 % is fed to
the input of the ramp generator or when attenuator [3] is effective, the ramp time shortens accordingly
The following is valid for type VT-VSPA1-1: The up and down
ramp times can be set separately to their minimum value (approx. 30 ms) with the help of the external contacts ramp up/
down OFF.

Differential input (input 2)


0 to +10 V / 4 to 20 mA

Command value input 2 is a differential input [1] (0 to + 10 V).


With the help of DIL switches 2) it can be congured as current input (4 to 20 mA or 0 to + 20 mA). If the command value
is fed forward by external electronics with a different reference
potential (e.g. by a PLC), this input must be used. When the
command value voltage is applied or withdrawn, care must be
taken that both signal cables are disconnected from or connected to the input.

Additions to the pin designations in brackets are only valid


for type VT-VSPA1-1.

123
RE 30111/09.05

3/12

Hydraulics Bosch Rexroth AG

VT-VSPA1-1 and VT-VSPA1K-1

Functional description (continued)


Ramp "up/down" OFF

VT-VSPA1-1
2a

Ramp "up" OFF

2c

Ramp "down" OFF

4ac

VT-VSPA1K-1

Summing amplier [5] adds the output signals of the characteristic curve generators [6 or 7] to the command value (can
be selected by means of DIL switches 2) depending on the
valve to be controlled). The current command value can also be
ltered through a low-pass lter that can be cut in. Current output stage [9] is controlled via current regulator [8]. In addition,
the current regulator modulates the current command value
with clock-pulse encoder signal [10] (the frequency can be programmed with the help of DIL switches 2)). The clocked actual
current value acts in the solenoid of the valve like a constant
current with overlaid dither signal. Type VT-VSPA1-1 is provided with measuring sockets for the internal command value
and the actual value.
The following is valid for the command value: +6 V

Ramp OFF

The following is valid for the actual value: 1 mV

100 %

1 mA

The signal "ready for operation" is output and LED "H2" on the
front panel (with VSPA1-1) or LED "H2" (with VSPA1K-1) is lit,
when:
The solenoid cables are not short-circuited and the output
stage is not overloaded,

The output signal of ramp generator [4] is fed as current command value to the summing amplifier [5]. Here, a command value of 100 % corresponds to a voltage of +6 V.

a command value is applied (cable break detection),


there is no cable break present on the solenoid cable.
1)

Reference potential for command value 1 is M0 (measuring


zero).

2)

For DIL switch settings, see "adjustment elements" on page 8

[ ] Cross-reference to block circuit diagrams on pages 4


and 5

01

12ac

4ac

2c

2a

on
5s

Current output stage


Clock-pulse generator

Max. command value attenuator 9


10
11

Ramp generator

Characteristic curve generator 1

Proportional solenoid of valve

17

16

14

13

17

off
1s

off
1.6 A

S2.6
on
on
off

S2.7
on
on
on

16

20ac

22ac

11

= Additional biasing current adjustment


(0 to 300 mA or 0 to 600 mA)

= Ramp time adjustment

= Command value attenuation

= Signal ready for operation

26c Ready for operation


24 V (50 mA)

26a Act. current value


1 mV 1 mA

Actual current value


"I"

i
9

ISoll

S2.4
off
on
off

S2.3 / S2.4

S2.3
off
off
on

S2.5
on
off
off

15

Zw
(R130)

Gw

H2

on
0.8 A

Output ready for operation

Low-pass filter

Power supply unit

Monitors

Command value monitoring

S1.7

S1.7
Imax

fclock
100 Hz
200 Hz
10
300 Hz

S1.6

S1.5

S2.5...S2.7

Char. curve 2

Char. curve 1

f3dB
0
2,5 Hz
4 Hz

Comm. value 0 to 6 V

VT-VSPA1-1 and VT-VSPA1K-1

Current regulator

Summator

Characteristic curve generator 2 12

+ 24 V

H2

2; 5; 15

14

DC

DC

13

&

S1.4
tmax

2,5 A T

2 x 220 F

S1.3
off
off
on

Differential input

24ac

18ac

12

S1.2
off
on
on

S1.4

+ 24 V

0V

9 V (25 mA)

16ac

14ac

10ac

Comm. value 2 S1.1


010 V
off
020 mA on
420 mA on

Gw

14ac

32ac

Hydraulics

M0 (25 mA)

+ 9 V (25 mA)

8ac

6ac

U/I

S1.1...S1.3

Zw (R130)

Command
value "w"

Bosch Rexroth AG

28ac
Command value
2 +10 V
4 - 20 mA / 0 - 20 mA 30ac
GND

Command value 1

Ramp "up" OFF


Ramp "down" OFF

Note: Measuring zero (M0) is raised by 9 V as against 0V operating voltage!

4/12

124
RE 30111/09.05

Block circuit diagram / pin assignment: VT-VSPA1-1

28

12

Low-pass filter

= Signal ready for operation

16
H2

Clock-pulse generator
Proportional solenoid of valve

10
11

Ramp generator

Characteristic curve generator 1

(R130)

= Additional biasing current adjustment


(0 to 300 mA or 0 to 600 mA)

Current output stage

Max. command value attenuator 9

11

26 Act. current value


1 mV
1 mA

20

22

= Command value attenuation

S2.7
on
on
on

= Ramp time adjustment

S2.6
on
on
off

16

Zw

S2.5
on
off
off

ISoll

S2.4
off
on
off

S2.3 / S2.4

S2.3
off
off
on

t
Power supply unit
14

Current regulator

on
0.8 A

Summator

off
1.6 A

2; 5; 15

S1.7
Imax

Monitors

S1.7

fclock
100 Hz
200 Hz
10 300 Hz

S2.5...S2.7

Command value monitoring Gw

H2

off
1s

13

13

&

on
5s

15

12

S1.3
off
off
on

S1.4
tmax

S1.6

Characteristic curve generator 2

14

DC

S1.2
off
on
on

2,5 A T

DC

12

S1.1
off
on
on

S1.4

S1.5

f3dB
0
2,5 Hz
4 Hz

Differential input

24

2 x 220 F

Comm. value 2
010 V
020 mA
420 mA

Gw

+ 24 V

18

16

14

10

U/I

S1.1...S1.3

Zw (R130)

32 Comm. value output


0 to 6 V
14

VT-VSPA1-1 and VT-VSPA1K-1

0V

9 V (25 mA)

M0 (25 mA)

+ 9 V (25 mA)

Command value 2 +10 V


4 - 20 mA / 0 - 20 mA 30
GND

Command value 1

Ramp
OFF

Note: Measuring zero (M0) is raised by 9 V as against 0V operating voltage!

RE 30111/09.05

125
Hydraulics Bosch Rexroth AG
5/12

Block circuit diagram / pin assignment: VT-VSPA1K-1

01

126
6/12

Bosch Rexroth AG

Hydraulics

VT-VSPA1-1 and VT-VSPA1K-1

RE 30111/09.05

Technical data (for applications outside these parameters, please consult us!)
UO +24 VDC +40 % 5 %

Operating voltage
Operating range:
Upper limit value

uO(t)max +35 V

Lower limit value

uO(t)min +22 V

Max. power consumption

Ps

Max. current consumption

50 VA

I 1.8 A

Fuse

Is 2.5 A T

Inputs:
Ui 0 to +9 V (reference potential is M0)

Command value 1
Command value 2 (differential input)

Ui 0 to +10 V; Ri = 100

or

Ii 4 to 20 mA (load RL = 100 )

or

Ii 0 to 20 mA (load RL = 100 )

Ramp time (adjustment range)

depending on setting
with S11 to S13

t 30 ms to approx. 1 s or 5 s (depending on setting with S14)

Outputs:
Output stage
Imax 800 mA +20 %, R20 = 19,5

Solenoid current/resistance
or
Biasing current at Imax = 800 mA
additionally

Imax 1600 mA +20 %, R20 = 5,4


Ib 50 mA or 100 mA

depending on setting
with S17 1)
depending on setting with
S17 and Zw (R130)

at Imax = 1600 mA

Ib 100 mA

at Imax = 800 mA

Ib 0 to 300 mA +20 %

at Imax = 1600 mA

Ib 0 to 600 mA +20 %

Adjustable by means of Zw
(R130) on the printed-circuit board

f 100 Hz, 200 Hz, 300 Hz or 370 Hz 10 % each


(depending on setting with S25 to S27)

Clock frequency
Signal ready for operation (only with VT-SPA1-1)
Component series 10 when ready for operation
in the case of a fault
From component series 11 when ready for operation
in the case of a fault
Regulated voltage

approx. UO

U <1V
U approx. UO, 50 mA

Load resistance > 10 k

U 0 V Ri = 10 k

U 9 V 1 %, 25 mA externally laodable

Measuring sockets
Command value w

U 0 to +6 V (+6 V

Actual current value I

U 0 to 1600 mV

100 % solenoid current), Ri = 1 k


0 to 1600 mA 20 mA

Type of connection:
VT-VSPA1-1

32-pin male connector, DIN 41612, form D

VT-VSPA1K-1

16-pin terminal strip

Card dimensions:

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08)

Width component side

3 TE

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +85 C

Weight
m 0.1 kg
The maximum current Imax can be set to the required value by
means of command value attenuator potentionmeter Gw.

1)

127
RE 30111/09.05

Hydraulics Bosch Rexroth AG

VT-VSPA1-1 and VT-VSPA1K-1

7/12

Output characteristic curves


Linear output characteristic curve (basic characteristic curve)

I2

1200 600
800 400
600 300
I1

Output current in mA

1600 800

400 200
200 100
0

50

100

01

Command value in %
I1

Adjustment range of biasing current Ib by means


of potentiometer "Zw" (R130) on the printed-circuit board

I2

Adjustment range of maximum command value by


means of potentiometer "Gw"

Characteristic curve with factory setting

Output characteristic curve with firmly set characteristics


(see adjustment instructions on pages 8 and 9)

1200 600
I2

Output current in mA

1600 800

800 400
400 200
IV

200 100
100 50
0
0

50

100

Command value in %

Iv

Biasing current curve 2 (qualitative representation)

I2

Adjustment range of maximum command value by


means of potentiometer "Gw"

Characteristic curve 1 (qualitative representation)

Characteristic curve 2 (qualitative representation)

128
8/12

Bosch Rexroth AG

Hydraulics

RE 30111/09.05

VT-VSPA1-1 and VT-VSPA1K-1

Indicator / adjustment elements


Potentiometer for biasing current adjustment

VT-VSPA1-1, component series 10

LED indicator lamp ready for operation"

DIL switch
group S2X

H2
Gw
BR21...BR27
1
2
3
4
5
6
7

ON

t
Ramp time up

X1

Max. command value (attenuator)

F2
2,5 A MT

R130
t

w
I

BR11...BR17

w
I

- Current command value


- Actual current value

ON

1
2
3
4
5
6
7

Ramp time down"

DIL switch group S1X

Potentiometer for bias- DIL switch


ing current adjustment group S2X

LED indicator lamp ready for operation"

H2

Max. command value (attenuator)

Gw

Ramp time up

Ramp time down"

w
I

- Current command value


- Actual current value

VT-VSPA1K-1

DIL switch
group S1X

7
6
5
4
3
2
1

Zw

7
6
5
4
3
2
1

F2
2,5 A T

w
I

Potentiometer for biasing current adjustment

DIL switch
group S2X

DIL switch
group S1X
2

Max. command value (attenuator)

Gw

Ramp time up"

Ramp time down"

7
6
5
4
3
2
1

F2
2,5 A T

X1

Zw

7
6
5
4
3
2
1

H2
32

LED indicator lamp ready for operation"


(SMD LED)

X1

VT-VSPA1-1, from component series 11

129
RE 30111/09.05

Hydraulics Bosch Rexroth AG

VT-VSPA1-1 and VT-VSPA1K-1

9/12

Indicator / adjustment elements (continued)


Assignment of DIL switch settings on the card to the valve
types (see also label on the printed-circuit board)
Setting for valve
types:
DBE(M)T, DBE(M)30,
DRE(M)30,
3DRE(M)10 1),
3DRE(M)16 1),
DBEP6A, DBEP6B,
3DREP6A, 3DREP6B,
pumps

S15 ... S17

S21 ... S27

(BR15 ... BR17)

(BR21 ... BR27)

1 2 3 4 5 6 7

ON

DBE(M)10-5X,
DBE(M)20-5X,
3DRE(M)10P-6X,
3DRE(M)16P-6X,
ZDRE10, (Z)DBE6

1)

1 2 3 4 5 6 7

Ramp time

5s

ON

1s

1 2 3 4 5 6 7

ON

ON

1 2 3 4 5 6 7

ON

ON

Command
value 2

1 2 3 4 5 6 7

ON
+10 V

01

1 2 3 4 5 6 7

1 2 3 4 5 6 7

ON

1 2 3 4 5 6 7

DRE6,
ZDRE6

S11 ... S14


(BR11 ... BR14)

1 2 3 4 5 6 7

ON

1 2 3 4 5 6 7

DRE(M)10-5X,
DRE(M)20-5X

Setting valid for all


valve types:

0 20 mA

ON

1 2 3 4 5 6 7

1 2 3 4 5 6 7

ON
X

4 20 mA

ON

Up to component series 5X

Meaning of potentiometers "Zw" (R130) and "Gw":

Note (X):

Adjustment of biasing current by means of potentiometer


"Zw" (R130)
Turning clockwise increase in biasing current
Turning counter-clockwise reduction of biasing current

With type VT-VSPA1-1 (component series 10) switch BR22


must be set to ON and potentiometer R130 turned to lefthand limit stop before the correct characteristic curve can be
set.

Adjustment of the max. command value by means of potentiometer "Gw"


Turning clockwise increase in command value
Turning counter-clockwise reduction of command value

With type VT-VSPA1-1 (from component series 11) and type


VT-VSPA1K-1, switch S22 is ineffective. Potentiometer "Zw"
needs not to be operated.

130
10/12

Bosch Rexroth AG

Hydraulics

RE 30111/09.05

VT-VSPA1-1 and VT-VSPA1K-1

Meaning of the DIL switches


Note (X):
Before commissioning the amplifiers, make sure that the DIL
switches on the printed-circuit board are set according to the
relevant application.
Switch positions with reference to the current valve types or previous amplifier cards
Valve types/amplifier cards

Switch

DBE(M)T, DBE(M)30
DRE(M)30, DRE(M)10 3)
DRE(M)16 3)
DBEP6A, DBEP6B
3DREP6A, 3DREP6B
pumps

DRE(M)10-5X
DRE(M)20-5X

DBE(M)10-5X
DBE(M)20-5X
ZDRE10
(Z)DBE6
3DRE(M)10P-6X
3DRE(M)16P-6X

DRE, ZDRE6

VT 2000

VT 2010

VT 2013

VT 2023

Characteristic curves
Basic characteristic curve

Characteristic curve 1

Characteristic curve 1

Characteristic curve 2

S15 (BR15)

OFF

ON

ON

OFF

S16 (BR16)

OFF

OFF

OFF

ON

Command value filters


f-3dB = 4 Hz

S23 (BR23)
S24 (BR24)

f-3dB = 4 Hz

f-3dB = 2.5 Hz

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

Max. output current


S17 (BR17)

1)

Imax = 800 mA

Imax = 800 mA

Imax = 1,6 A

Imax = 1.6 A

ON

ON

OFF

OFF

Clock frequency 2)
f = 200 Hz

f = 200 Hz

f = 300 Hz

f = 370 Hz

S25 (BR25)

OFF

OFF

OFF

OFF

S26 (BR26)

ON

ON

OFF

OFF

S27(BR27)

ON

ON

ON

OFF

Basic biasing current setting


Zw (R130)

100 mA

50 mA

100 mA

100 mA

1)

Doubling of the maximum output current doubles the


adjustment range and the set biasing current.

Adjustment range of biasing current using potentiometer Zw


(R130):

2)

For f = 100 Hz, DIL switches S25, S26 and


S27 must be set to the ON position.

Imax = 800 mA Ib = 0 to 300 mA

Up to component series 5X

( ) valid for VT-VSPA1-1, component series 10

3)

Imax = 1600 mA Ib = 0 to 600 mA

When switch BR22 is operated, the biasing current increases


by 50 mA or 100 mA.
Adjustment options inedependent of the valve type (command value 2 and ramp time)
Configuration of differential input
S11 (BR11)
S12 (BR12)
S13 (BR13)

Command value 2: +10 V


OFF
OFF
OFF

Command value 2: 0 to 20 mA
ON
ON
OFF

DRE, ZDRE6

Command value 2: 4 to 20 mA
ON
ON
ON

Max. ramp time


S14 (BR14)

OFF

1s

Factory setting (corresponds to the configuration of a VT 2000 amplifier)

ON

5s

131
RE 30111/09.05

Hydraulics Bosch Rexroth AG

VT-VSPA1-1 and VT-VSPA1K-1

11/12

Unit dimensions (nominal dimensions in mm)


VT-VSPA1-1
H2

100
89

3HE (128,4)

Gw
t
t

w
I
M0

VSPA1

4TE
(20)

2
7

165
182

01

164

104
100
80

X1

VT-VSPA1K-1

10

4 x 4,5

10

135
160

Engineering / maintenance notes / supplementary information


Before commissioning the amplifiers, make sure that the DIL switches on the printed-circuit board are set according to the
relevant application.
The factory setting of the parameters is as follows (for the adjustment of parameters, see pages 8 to 10):
max. ramp time = 5 s, biasing current = 100 mA, max. output current = 800 mA, clock frequency = 200 Hz
The amplifier card may only be installed when disconnected from the power supply!
Do not use plugs with free-wheeling diodes or LED lamps for connecting the solenoids!
Measurements on the card may only be taken with instruments Ri > 100 k !
Measuring zero (M0) is raised by +9 V as against 0 V operating voltage and not electrically isolated, i.e. 9 V regulated voltage
0 V operating voltage. For this reason, do not connect measuring zero (M0) to 0 V operating voltage!
Use relays with gold-plated contacts for passing on command values (small voltages, small currents)!
Always shield command value cables; connect the shield to ground on the card side and leave the other end open. Connect the
card to ground at terminal 6 or 8. If no system ground is provided, connect 0 V operating voltage.
Recommendation: Also shield solenoid cables!
For solenoid cables of up to 50 m length, use cable type LiYCY 1.5 mm2. For greater lengths, please consult us!
The distance to aerial lines, radio sources and radar equipment must be at least 1 m!
Do not lay solenoid and signal cables near power cables!
Due to the charging current of the smoothing capacitor on the card, fuses must feature slow-blowing characteristics!
Caution!
Note!

When the differential input is used, both inputs must always be switched on or off simultaneously!
Electrical signals (e.g. signal ready for operation) brought out via control electronics must not be used for
switching safety-relevant machine functions!
(See also European standard Safety requirements for fluid power systems and components - hydraulics,
EN 928.)

132
12/12

Bosch Rexroth AG

Hydraulics

VT-VSPA1-1 and VT-VSPA1K-1

RE 30111/09.05

Troubleshooting
If the amplifier cards are not operable, follow the steps below
for troubleshooting:
1. Is the operating voltage applied?
Measurement of contacts 24(ac) against 18 (ac)
2. Fuse on the card defective?
3. Internal 9 V operating voltage available on the card?
4. When the internal command value potentiometer is used,
is the jumper from 10(ac) to 12(ac) plugged?
5. Is the external potentiometer properly connected?
6. Is the differential input properly connected?
Check:
Reference potential to 30(ac)
0 to +10 V to 28(ac)

Note:
The output stage shuts down in the case of excessive temperatures (e.g. caused by overloading). This fault is signalled by
LED "H2" going out!
In the event of a cable break of the "4 to 20 mA" input, the signal "ready for operation" is reset and LED "H2" also goes out.
The following is valid from component series 11 onwards:
In the case of a short-circuit or cable break of the solenoid cable, the output ready for operation is switched and LED "H2"
flashes at a frequency of 0.5 to 2 Hz as soon as the command
value is > 2 % at the same time.

7. Is the solenoid properly connected?


When the card is unplugged, a resistance of approx. 20
to 30 or 5 to 8 , depending on the valve, must be
measurable between contacts 22ac and 20ac.
The additions to the contact designations are only valid for type
VT-VSPA1-1.

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

133

RE 30115/06.05
Replaces: 09.03

Electrical amplifiers

1/10

Types VT-VSPA1-2 and VT-VSPA1K-2

Component series 1X

H7109_d

Table of contents

Features

Features

Suitable for controlling pressure valves of type DBET, component series 6x or as universal amplifier (see technical data)

Ordering code, accessories

Differential input (0 to +10 V)

Contents

Page

Function

2 and 3

Current input (4 to 20 mA)

Block circuit diagrams

4 and 5

4 command value call-ups (only in conjunction with option A4)

Adjustment and control elements

6 and 7

Technical data

8 and 9

Ramp generator with separately adjustable ramp time for up/


down

Unit dimensions
Engineering/maintenance notes/supplementary information

9
10

External ramp time selection


Enable input
Clocked current output stage
Signal ready for operation
Reverse polarity protection of supply voltage
Short-circuit protection of solenoid cable
Solenoid cable break detection

134
2/10

Bosch Rexroth AG

Hydraulics

VT-VSPA1-2 and VT-VSPA1K-2

RE 30115/06.05

Ordering code
VT-VSPA1

1X V0

*
Further details in clear text
(additional functions on enquiry)

Amplifier for controlled proportional pressure valves,


analogue, with one solenoid
With 48-pin male connector and front panel
= No code
With 16- or 24-pin terminal strip without front panel
=K
Component series 10 to 19
(10 to 19 unchanged technical data and pin assignment)

0=
A4 =
...

= 1X

Standard option
Variant with 4 command value call-ups

V0 =

Basic version

Available accessories
Suitable card holders:
19 rack types VT 19101, VT 19102, VT 19103 and VT 19110
(see RE 29768)
Enclosed card holder type VT 12302 (see RE 30103),
in conjunction with blind plate 4TE/3HE,
material no. R900021004

Open card holder type VT 3002-2X/48F (see RE 29928),


only for installation in control cabinets!
Suitable power supply unit:
Type VT-NE30-2X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC,
108 W
Test unit:
Type VT-PPV-1X, see RE 29687

Function
Power supply unit (1)
The amplifier card is fitted with a power supply unit with switchon current limitation. This power supply unit provides all internally required positive and negative supply voltages. The
switch-on current limitation prevents high switch-on current
peaks caused by the smoothing capacitors in the current output stage.

Only one call-up is possible at a time. If several call-ups are activated simultaneously, call-up w1 has the lowest and call-up
w4 the highest priority.
The currently active call-up is signalled by a yellow LED.
Enable function (7)

The internal command value signal is the sum (6) of the external command value signal applied to differential input (2) or
current input (3) or the called up signal (4) 1) and the zero point
offset (5) (zero point potentiometer Zw).

The enable function (7) is used to enable the current output


stage and to pass the internal command value signal on to the
ramp generator (8). The enable signal is signalled by an LED.
When the enable is given (via 24 V input or jumper J1), the internal command value (with any command value selection)
changes over the set ramp time. The valve will therefore not
open suddenly when activated.

The following is valid:

Ramp generator (8)

Command value selection (2), (3), (4) 1), (5), (6)

Standard
values

Current
input

Differential
input

Command
value socket

0%

4 mA

0V

0V

+100 %

20 mA

+10 V

+10 V

Ramp generator (8) limits the gradient of the control output.


The downstream amplitude limiter (12) does not shorten or extend the ramp time. The ramp time can be changed by a factor
of 10 by means of jumper J3.
The following is valid:
J3

There is no changeover between current and voltage input. The


inputs are permanently available (see block circuit diagram).
Command value call-ups (4) 1)
It is possible to call up four command value call-ups w1 to
w4. The external voltages (command values 1 to 4) are fed
forward either directly via the voltage output +10V or via external potentiometers. If the command value inputs are connected
directly to the regulated voltage, the command values can be
adjusted by means of potentiometers w1 to w4. If external
potentiometers are used, the internal potentiometers act as attenuators or limiters.
1)

Provided only in conjunction with option A4

open*

Usocket /V

0.2

0.1

0.02

t/msec

50

100

500

1000

5000

t/sec

0.5

10

50

* Basic setting (factory setting)


Formula:
t =

100 msec
Usocket / V

135
RE 30115/06.05

3/10

Hydraulics Bosch Rexroth AG

VT-VSPA1-2 and VT-VSPA1K-2

Function (continued)
Ramp ON/OFF (9)

use, jumper J6 must be opened.

Jumper J2 or the ramp ON/OFF input (9) (see terminal assignment) can be used to set the ramp time to a minimum (<50 ms).

Frequency balancing by means of the frequency potentiometer is possible with the help of jumper J7.

The activation of a ramp is signalled by an LED.

Example 1:

Ramp ON/
OFF input

J2

LED T

Ramp

(Frequency balancing by means of frequency potentiometer - independently of the command value; J6 = open, J7 =
plugged)

0V

open

ON

ON

Adjustment range: 210 Hz 310 Hz 15 %

+24 V

open

OFF

OFF

Example 2:

0V

plugged

OFF

OFF

+24 V

plugged

ON

ON

(Command value-related frequency J6 plugged)


450

UO

400

The internally set ramp time can be extended by means of an


external potentiometer or an external voltage selection (according to the formula given in the section Ramp generator). The
setting can be checked at the measuring socket. In the case of
a cable break, the internal setting is automatically valid.

350

28 V
24 V

The adjustment range depends on R. The following is valid:


Adjustment range *

Frequency in Hz *

External ramp time adjustment (10)

34 V

300

18 V

250
200
150
100
50

Min. ramp time


Rotary angle of the
potentiometer at lefthand limit stop

Max. ramp time


at rotary angle of
the potentiometer
of approx. 95 %

1 kOhm

100 ms

1s

* Tolerance: 15 %

100 Ohm

1s

10 s

The frequency potentiometer can be used to correct the frequency by > 10 % (J6 and J7 plugged).

* The minimum ramp time can only be achieved, if the internally


set ramp time is smaller, i.e. the corresponding potentiometer
is at its left-hand limit stop. The specified ramp times are valid
when J3 = open.
Characteristic curve generator (11)
Potentiometer Gw (12) is used to adjust the maximum current
for the solenoid. Characteristic curve generator (11) changes
the command value signal so that a linear command value/
pressure characteristic curve is obtained (corrected characteristic curve adapted for DBET-6X). To this end, characteristic
curve generator (11) must be activated via jumper J4, and jumper J5 must be opened!
For deactivating the characteristic curve, jumper J4 must be
opened and jumper 5 plugged. This activates linear curve characteristics.
Amplitude limiter (12)
The internal command value is limited to approx. +120 % of the
nominal range.
Command value output (13)
0 % > 0 V

+100 % > +10 V

Clock-pulse generator (14)


The clock-pulse generator (14) generates a frequency for the
output stage. The supply voltage has an influence on the frequency.
A frequency that depends on the command value signal can be
generated via jumper J6 (adapted for DBET-6X). For universal

0
0

20

40
60
80
Command value in %

100

Current output stage (15)


The current output stage generates a clocked solenoid current
for the proportional valve.
The output stage output is de-energised in the case of an internal fault signal or missing enable. The output of the output
stage is short-circuit-proof.
Actual value output (16)
1 mA (Isolenoid) = 1 mV (actual value output)
Fault detection (17)
The solenoid cable is monitored for cable break and short-circuit. When no fault is present, a voltage >16 V is output at the
ready-for-operation output, and the ready-for-operation LED
is lit. In the event of a fault, the voltage drops to <1 V and the
LED flashes.
Command-value-reached output (18) function on enquiry!
When the internal command value corresponds to the command value selection after the ramp and no fault is present, a
signal of >16 V is output at the command-value-reached output.
When the enable is missing, a signal >16 V is output as soon
as the internal command value reaches 0 %.

01

10

b12

10k

-1

t<

t<
t>

Ramp time selection logic

L0

DC

w2

(3) Current input

14

UL

16

ok

U
I

18

15

UL

(18) Output comm. value-reached (on enquiry)

Char. curve generator (17) Fault detection

(6) Comm. value summation (12) Amplitude limiter

(5) Zero point adjustment (11)

(16) Actual value output

(15) Current output stage

Ramp ON/OFF

(4) Command value call-ups* (10) External ramp time

(14) Clock-pulse generator

Ramp generator

(9)

17

ok

(8)

&

Frequency

(2) Differential input

Reserve jumper

J8

Fcult detection

J4

J5

J7

PWM

(13) Comm. value output

7,5 V

UL

11

Enable

50

12

f
(z, y)

f (y, z) z

Enable

Power supply unit

DC

w1

Gw

f
(z)

(7)

(1)

J3

T ramp max/sec

J6

Actual value

Solenoid

Internal command value

Ready for operation

Signal comm. value


reached
(on enquiry)

z20 System ground

b28 External
reference

d26

b32 +10 V/25 mA

d22

d20 Reserved

z10

d32

z2
z4

d30

VT-VSPA1-2 and VT-VSPA1K-2

*Only provided for option A4

0 V z32

J1

w3

ok

J3

Hydraulics

24 V z30

Enable d18

+
Comm. value 5: +10V
Comm. value 6: 4-20 mA +

Command value 4*
Command value 3*
Command value 2*
Command value 1*
Comm. value call-up 4*
Comm. value call-up 3*
Comm. value call-up 2*
Comm. value call-up 1* d2

max t

Up/down

PWM frequency

J6

13

Bosch Rexroth AG

+ 7,5 V
+ 10 V
M0

t>

b14
2
>50k
U
b16
>50k
U
6
3
b22

I
100
b24
U
b8 100k w4
4
b6
5
100k w3
Comm. value
b4
100k w2
Zw
b2
100k
w1 selection logic
d8
d6
d4
w4

+15V

d24
External ramp time + d28 U

Ramp ON/OFF

J2

4/10

136
RE 30115/06.05

Block circuit diagram VT-VSPA1-2

10

>50k

>50k

U
6

DC

w1

DC

w2

w3

Enable

50

11

J8

Fault detection

(11)

16

ok

UL

13

18

15

UL

(18) Output comm. value-reached (on enquiry)

Char. curve generator (17) Faut detection

(6) Comm. value summation (12) Amplitude limiter

(5) Zero point adjustment

(16) Actual value output

(15) Current output stage


Ramp ON/OFF

(4) Command value call-ups* (10) External ramp time

(9)

17

ok

(3) Current input

&

frequency

(14) Clock-pulse generator

J4

J5

J7

PWM

14

f (y, z) z

Ramp generator

12

f
(z, y)

(8)

Reserve Jumper

J3

Gw

f
(z)

(2) Differential input

UL

J6

PWM frequency

J6

(13) Comm. value output

7,5 V

+ 7,5 V
+ 10 V
M0

ok

J3

T ramp max/sec

max t

Up/down

Enable

Zw

w4

t>

Comm. value
selection logic

t<

Ramp time selection logic

Power supply unit

w1

(7)

(1)

100k

w2

100k

w3

L0

J1

100k

w4

*Only provided for option A4

100k

100

10k

+15V

-1

14

10

12

1
2

+10 V/25 mA

Ready for operation

Signal comm. value


reached
(on enquiry)

Actual value

External reference

Solenoid

Internal command value

VT-VSPA1-2 and VT-VSPA1K-2

0 V 16

24 V

15

Enable 7

Comm. value 5: +10 V +

+
Comm. value 6: 4-20 mA
Command value 4*
Command value 3*
Command value 2*
Command value 1*
Comm. value call-up 4*
Comm. value call-up 3*
Comm. value call-up 2*
Comm. value call-up 1* 21

5
6
8
9
20
19
18
17
24
23
22

11
External rampe time + 13

Ramp ON/OFF

J2

RE 30115/06.05

137
Hydraulics Bosch Rexroth AG
5/10

Block circuit diagram VT-VSPA1K-2

01

138
6/10

Bosch Rexroth AG

Hydraulics

VT-VSPA1-2 and VT-VSPA1K-2

RE 30115/06.05

Adjustment and control elements

VT-VSPA1-2:

J5

J3

Rexroth

Frequency potentiometer

J2

Zero point balancing Zw


Amplitude attenuator Gw
Comm. value 1 w11)
Comm. value 2 w21)
Comm. value 3 w31)
Comm. value 4 w41)
Ramp UP t <
Ramp DOWN t >

Zw
Gw
w1
w2
w3
w4
t<
t>

t<
f

t>
w
I

J7

Nameplate

Ready
Enable
Ramp activated

J6
J4

Measuring
sockets

J8

VSPA1-2

J1 Fuse 2 A, medium time lag

Ramp activated

J3

J5 J2

17
18
19
20
21
22
23
24

VT-VSPA1K-2:
Frequency potentiometer

Enable

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Ready for operation


enable

Zero point balancing Zw


Amplitude attenuator Gw
Command value 1 w11)
Command value 2 w21)
Command value 3 w31)
Command value 4 w41)
Ramp DOWN t <
Ramp UP t >

w1
w2
w3
w4

J7

J6
J4

W
I

J8
1)

Only provided for option A4

J1 Fuse 2 A, medium time lag

139
RE 30115/06.05

VT-VSPA1-2 and VT-VSPA1K-2

Hydraulics Bosch Rexroth AG

7/10

Adjustment and control elements (continued)


Measuring sockets (contacts)
t<:

Ramp time ramp UP

t>:

Ramp time ramp DOWN

w:

Command value output (0-10 V)

I:

Actual value (1 mV 1 mA )

f:

Clock-pulse frequency of output stage

Reference for outputs

Additional potentiometers:
Frequency: Frequency adjustment
(to be activated by means of J7)

01
LEDs:

Ready-for-operation LED
Enable LED

T:

Ramp-ON-active LED

w1-w4:

LEDs command value call-up active


(only with A4 variant)

Jumpers:
J1 open:
plugged:
J2

No enable
Enable activated
Ramp function ON/OFF ( = open)
(see table under Ramp ON/OFF on page 3)

J3 open:
plugged:

Ramp time 20 ms to 5 s
Ramp time 200 ms to 50 s

J4 open:
plugged:

Corrected line deactivated


Corrected line activated

J5 open:
plugged:

Linear characteristic curve deactivated


Linear characteristic curve activated

J6 open:
plugged:

Command value-related frequency deactivated


Command value-related frequency activated (DBET-6X)

J7 open:
plugged:

Frequency matching by means of frequency potentiometer deactivated


Frequency matching by means of frequency potentiometer activated

J8 Reserve

( = plugged)

Factory setting of jumpers:

140
8/10

Bosch Rexroth AG

Hydraulics

VT-VSPA1-2 and VT-VSPA1K-2

RE 30115/06.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC + 40 % 20 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 18 V

Power consumption

PS < 24 VA

Current consumption

I <2A

Fuse

IF 2 A medium time lag, replaceable

Inputs:
Analogue
Command values 1 to 4 (potentiometer inputs) *

Ue 0 to +10 V, Re > 100 k

Differential input

Ue 0 to +10 V, Re > 50 k

Current input
Ramp time external

Ie 4 to 20 mA, load RL = 100


Ue 0 to +5 V, Ri > 10 k

Digital
Command value call-ups*

U 8.5 V to UO > call-up active, Ri > 100 k


U 0 V to 6.5 V > no call-up, Ri > 100 k

Ramp call-ups

U 8.5 V to UO > call-up active, Ri > 100 k


U 0 V to 6.5 V > no call-up, Ri > 100 k

Ramp ON/OFF

U 8.5 V to UO > ramp ON, Ri > 100 k


U 0 V to 6.5 V > ramp OFF, Ri > 100 k

Enable

U 8.5 V to UO > ON, Ri > 100 k

*Provided only for option A4

U 0 V to 6.5 V > OFF, Ri > 100 k

Clock-pulse frequency:

f 250 Hz 10 %
when J6 and J7 = open

Adjustment ranges:
Zero balancing (potentiometer Zw)

+30 %

Command values (potentiometers w1 to w4)

0 to 100 %

Ramp times (potentiometers t < and t >)


Amplitude attenuator (potentiometer Gw)
Frequency matching with potentiometer (J7 active)

t 20 ms to 5 s, can be changed over to 0.2 s to 50 s


0 to +120 %
f see explanation: Clock-pulse generator, page 3

Output signals
Command value signal

U 0 to +10 V 2 %, Imax = 2 mA

Actual value signal

U 0 to +10 V 2 %, Imax = 2 mA

Ready for operation

U > 16 V, Imax = 50 mA
(in the event of a fault: U < 1 V, Ri = 10 k

Output command value reached on enquiry

U > 16 V, Imax = 50 mA (when command value reached)


(when command value not reached: U < 1 V, Ri = 10 k

Regulated voltage

U +10 V 2%, Imax = 25 mA, short-circuit-proof

Ramp signal measuring sockets

U +100 mV to +5 V 10 %,
+10 mV to +100 mV 50 %

Current output stage

I 0 to 1.9 A, short-circuit-proof, clocked

Type of connection:
VT-VSPA1-2

48-pin male connector, DIN 41612, form F

VT-VSPA1K-2

16 or 24-pin terminal strip

141
RE 30115/06.05

Hydraulics Bosch Rexroth AG

VT-VSPA1-2 and VT-VSPA1K-2

9/10

Technical data (continued)


Card dimensions:

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions (refers to VT-VSPA1-2)


Height

3HE (128.4 mm)

Width soldering side

1TE (5.08 mm)

Width component side

3TE (15.24 mm)


0 to 50 C

Permissible operating temperature range


Storage temperature range

-25 to + 85 C

Weight

m 0.15 kg (net)

01

Unit dimensions (nominal dimensions in mm)


VT-VSPA1-2:

Rexroth

Example: VT-VSPA1-2-1X/V0/A4

3HE
(128,4)

Zw
Gw
w1

89
100

w2
w3
w4
t<
t>

t<

t>
w
I

VSPA1-2

165
182

4TE
(20,3)

8
VT-VSPA1K-2:
Example: VT-VSPA1K-2-1X/V0/A4
enable

104
100
80

w1
w2
w3

10

w4

10

135
160
164

142
10/10

Bosch Rexroth AG

Hydraulics

VT-VSPA1-2 and VT-VSPA1K-2

RE 30115/06.05

Engineering/maintenance notes/supplementary information


The factory settings of parameters are as follows: Corrective characteristic curves and command value-dependent frequency =
active (matched to DBET-6X): max. ramp time = 5 s, biasing current = 100 mA, max. output current = 1.6 A
The amplifier card may only be installed when disconnected from the power supply!
Do not use plug-in connectors with free-wheeling diodes or LED indicator lamps for connecting the solenoid!
Measurements on the card may only be taken using instruments Ri > 100 k!
Use relays with gold-plated contacts for passing on command values (small voltages, small currents)!
Always shield command value cables; connect the shield to ground on the card side and leave the other end open. If no system
ground is provided, connect 0 V operating voltage.
Recommendation:

Shield also solenoid cables! For solenoid cables up to 50m length, use cable type LiYCY 1.5mm2.
In the case of greater lengths, please consult us!

The distance to aerial lines, radio sources and radar equipment must be at least 1m!
Do not lay solenoid and signal cables near power cables!
Caution:

When the differential input is used, both inputs must always be activated or deactivated simultaneously.

Note:

Electrical signals brought out via control electronics (e.g. signal ready for operation) must not be used for
switching safety-relevant machine functions!
(See also European standard safety requirements for fluid power systems and components
- hydraulics, EN 982.)

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

143

RE 30110/06.05
replaces: 10.04

Analogue amplifier card

1/10

Type VT-VSPA2-1-2X/

H/A/D 6641/00

Table of contents

Features

Contents

Page

Features

Ordering details, accessories

Function

Block circuit diagram and connection allocation

4 and 5

Technical data

6 and 7

Characteristic curves
Display and adjustment elements

Suitable for controlling valve types 4WRA nominal sizes 6


and 10, series 2X and WRZ series 7X
Built-up in the form of a board in the Euro-format
100 x 160 mm and is suitable for mounting into a rack
Command value inputs:

7
8 a nd 9

Unit dimension

10

Engineering / maintenance guidelines, additional information

10

Differential input 10 V
Four command value inputs,
10 V that can be called up
Current input 4 to 20 mA

Inverting the internal command value signal via the 24V input
or jumper
Selecting the ramp time via quadrantal recognition (24V input) or
ramp time call-ups (24V inputs) (option T5)
Switching over the ramp time range via jumpers
Characteristic curve correction by separately adjustable jump
heights and maximum values
Enable input
Ramp on/off input
Output signal operational
Switchable measuring socket (option T5)
Polarity protection for the supply voltage
Power supply with DC/DC convertor without a raised zero
point

144
2/10

Bosch Rexroth AG

Hydraulics

VSPA2-1-2X

RE 30110/06.05

Ordering details

VT-VSPA2

2X V0

*
Further details in clear text1)

Analogue amplifier in Eurocard format


For controlling valve types:
4WRA 62X; 4WRA 102X; 4WRZ7X
Series 20 to 29
(20 to 29 unchanged technical data
and connectional allocation

1)

T1 =
T5 =

=1

Basic version
= 2X

E.g. Output stage monitoring or command value


reached signal on request

Suitable card holders:


19 rack types VT 19101, VT 19102, VT 19103 and VT 19110
(see RE 29768)
Enclosed card holder type VT 12302 (see RE 30103) with
use of a blind plate 4TE/3HE (material no. R900021004)
Open card holder type VT 3002-2X/48F (see RE 29928)
Only for installation in control cabinet !
Suitable power supply unit:
Type VT-NE30-2X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC,
108 VA

With one ramp time


With five ramp times

145
Hydraulics Bosch Rexroth AG

RE 30110/06.05 VSPA2-1-2X

3/10

Function
Power supply [1]
The amplifier card has a power supply with an inrush current
limiter. This supplies all of the internal positive and negative
supply voltages. The inrush current limiter prevents inrush
current peaks caused by the smoothing capacitors in the
current output stage.

Command value inversion [7]


The internally generated command value which is formed from
the input signals, command value call-ups and zero point off-set
signal can be inverted by means of an external signal or via
jumper J1. The inversion is displayed via a LED ( 1) on the
front plate.

Applied command value


The internal command value signal is formed from the sum
of the external command value being applied to the differential
input [2] and the command values being applied to the
summator [6] and the ramp generator.
The following is valid:

Enable function [8]


With the enable function the current output stages are released
and the internal command value signal is switched to the ramp
generator. The enable signal is displayed on the front panel by
means of a LED. If the enable is withdrawn, the internal
command value (with an applied command value) changes with
the set ramp time. The valve being controlled therefore does not
open suddenly.

1)

Standard
value

Current
input

Differential
input

Com.
value
socket

Flow
direction

100%

4 mA

10 V

10 V

P to B,
A to T

0%

12 mA

0V

0V

100 %

20 mA

10 V

10 V

0%

< 1 mA1)

P to A,
B to T

0V

If the current input is not switched or with current command


value a cable break results in an internal command value
signal 0 %.

No switching takes place between the current and voltage


inputs. The inputs are permanently available (see pin allocation).
Command value call-ups [4]
Four command value signals w1 to w4 can be called-up.
The external command value voltages (command values 1 to
4) are either directly applied via the controlled voltage outputs
+10 V and 10 V or via an external potentiometer. If the
command value inuts are directly applied to the controlled
volatages then the settings are done on potentiometers w1
to w4. When using external potentiometers then the internal
potentiometers act as attenuatators or limiters.
Only one call-up at the same time is possible. If more than one
call-up is activated at the same time then call-up 1 has the
lowerst priority and call-up 4 the highest priority.
The active call-up is displayed via a yellow LED on the front
plate.

Ramp generator [9]


The ramp generator limits the rate of adjustment variable
increase. The subsiqent jump functions and amplitude
attenuation are not lengthed or shortened by the ramp time.
With a ramp on/off signal or mit with jumper J2 the ramp time
is set to a minimum (< 2 ms) (ramp off).
External ramp time adjustment
With an external potentiometer it is possible to lengthen the
internally set ramp time. The setting can be checked with the
aid of the measuring socket. In the case of a cable break the
internal setting is automatically valid.
Characteristic curve generator [10]
With the adjustable characteristic curve generator it is possible
to separately adjust the maximum values for the positive and
negative signals so that they can be matched to suit the
hydraulic requirements. the actual movement of the
characteristic curve through the zero point is not in the form of
a jump but is linear.
Amplitude limiter [11]
The internal command value is limited to approx. 110 % of the
nominal range.
Clock generator [13]
The clock generator produces the clock frequency for the output stages. The clock signal can be switched, via a jumper, into
one of three basic frequency ranges.
Current output stage [16]
The current output stage produces the clocked solenoid current
for the proportional valve. The solenoid current is limited to
2.7 A per output. The output stage outputs are short circuitproof. The output stages are de-energised in the case of an
internal fault signal or missing enable.
Fault recognision [17]
Monitors via current the output stage.
[ ] = Cross reference to the block circuit diagram
on pages 4 and 5

01

z30

b10
d18

d2
1
d4
2
d6
3
d8
4

b2

b4

b6

b8

b18
z24
z26
z28

w4

Current input

Com. value selection logic

Zero point adjustment

100 F

UL

Enable

Differential input

w1

w2

Power supply

DC

J1 -1

J4

S+

+15V
+7,5 V
+5V
M0
5 V
7,5V
15 V

Gw+

ok

Ramp generator

Enable function

Com. value inversion

J3

J8 J9

S-

t3

t2
t
t4

10

14 Act. current output

13 Clock generator

12 Com. value output

11 Amplitude limiter

12

17

ok

17 Fault recognition

16 Current output stage

15 Current controller

&

14

U
16
I

UL

J7

J5 J6

13

ok

Controller

15

Fault recognition

Enable

11

10 Characteristic curve generator

Gw-

t1

max t

Com. value summation

DC 1

Zw 5

UP/DOWN

z20

b28

b26

b30

b32

d22

d20

d32

z10

z14
z16

z12

z18

z6
z8
z2
z4

z22

d30

d26

System earth

M0

Ramp time

Measurement signal

10 V / 25 mA

+10 V / 25 mA

Operational

Reserved

Actual value

Solenoid a

Solenoid b

Reserved

Reserved
Internal com. value

VSPA2-1-2X

L0

w3

J2

Hydraulics

Operating 24 V
voltage
z32
0V

Inversion
Enable

Com. value
call-ups

Com. value 1

Com. value 2

Com. value 3

Com. value 4

Com. value 6
4-20 mA

b14
+
b16

b22
+
b24

d24
d28

+15 V

d10
d12
d14
d16

b20

b12

Bosch Rexroth AG

Com. value 5
10 V

Ramp time
external

Ramp on/off

4/10

146
RE 30110/06.05

Block circuit diagram / connection allocation; VT-VSPA2-1-2X/V0/T1

Operating
voltage

Inversion
Enable

Com. value
call-ups

Com. value 4
Com. value 3
Com. value 2
Com. value 1

Com. value 6
4-20 mA

Com. value 5
10 V

Ramp time
external

Ramp
call-ups

Ramp on/off
4-Quadrant
operation

0V

24 V

Current input

Com. value selection logic

Zero point adjustment

t3

DC

Zw 5

t4

t5

DC

J1 -1

J4

S+

F
t2

J3

+
-

t
t4

10

15 Current controller

14 Actual current output

13 Clock generator

Enable

11

15

12

ABCD

17

ok

19 Ramp time selection logic

18 Measuring point switchover

17 Fault recognition

UL

16 Current output stage

18

0123456789ABCDE F

Measuring points

&

14

U
16

J7

J5 J6

13

ok

Controller

Fault recognition

12 Com. value output

11 Amplitude limiter

J8 J9

S-

9 t3

Gw-

t1

max t

+15V
+7,5 V
+5V
M0
5 V
7,5V
15 V

Gw+

10 Characteristic curve generator

Ramp generator

Enable function

Com. value inversion

4Q
UP/DOWN

ok

Com. value summation

19

z20

b28

b26

b30

b32

d22

d20

d32

z10

z14
z16

z12

z18

z6
z8
z2
z4

z22

d30

d26

System earth

M0

Measurement signal

10 V / 25 mA

+10 V / 25 mA

Operational

Actual value
Reserved

Solenoid a

Solenoid b

Reserved

Reserved
Internal com. value

Hydraulics Bosch Rexroth AG

100 F

UL

Enable

w1

w2

Differential input

t2

L0

w3

Power supply

w4

t1

J2

b18
z24
z26
z28

z32

z30

b10
d18

d2
1
d4
2
d6
3
d8
4

b2

b4

b6

b8

b14
+
b16

b22
+
b24

d24
d28

d10
1
d12
2
d14
3
d16
4
+15 V

b20

b12

EF 0

34
12 5

6789

RE 30110/06.05 VSPA2-1-2X

147
5/10

Block circuit diagram / connection allocation; VT-VSPA2-1-2X/V0/T5

01

148
6/10

Bosch Rexroth AG

Hydraulics

VSPA2-1-2X

RE 30110/06.05

Technical data (for applications outside these parameters, please consult us!)
UB 24 VDC + 40% 20%

Operating voltage
Functional range:
Upper limiting value

UB (t)max 35 V

Lower limiting value

UB (t)min 18 V

Power consumption

PS < 50 VA

Current consumption

I < 2A
IS 2 A medium slow, replacable

Fuse
Inputs:
Analogue
Com. value 1 to 4 (potentiometer inputs)

Ue 0 to 10 V; Re > 100 k (ref. is M0)

Com. value 5 (differential input)

Ue 0 to 10 V; Re > 50 k

Com. value 6 (current input)


External ramp time

Ie 4 to 20 mA; load RB = 100


Ue 0 to + 10 V; Re = 10 k (raised internally to +15 V; ref.
is M0)

Digital
Command value call-ups

U 8.5 V to UB > call-up actuated; Re > 100 k


U 0 to 6.5 V > no call-up; Re > 100 k

Ramp call-up (option T5)

U 8.5 V to UB > call-up actuated; Re > 100 k


U 0 to 6.5 V > no call-up; Re > 100 k

Quadrant recognision

U 8.5 V to UB > ON; Re > 100 k

Command value inversion

U 8.5 V to UB > ON; Re > 100 k

U 0 to 6.5 V > OFF; Re > 100 k


U 0 to 6.5 V > OFF; Re > 100 k
Enable

U 8.5 V to UB > ON; Re > 100 k

Ramp

U 8.5 V to UB > ON; Re > 100 k

U 0 to 6.5 V > OFF; Re > 100 k


U 0 to 6.5 V > OFF; Re > 100 k
Setting ranges
Zero compensation (potentiometer Zw)

30%

Command value (potentiometers w1 to w4)

0% to 110%

Ramp times (potentiometers t1 to t5)

20 ms to 5 s; switchable 0.2 to 50 s

Jump height (potentiometers S+ and S)

0% to 50%

Amplitude attenuation (potentiometers G+ and G)

0% to 110% (valid when setting the jump height from 0%)

Outputs
Command value signal

U 10 V 2 %; Imax = 2 mA

Actual value signal

U 2.5 V 2 %; Imax = 2 mA (mV

Measuring point signal (option 5)

U 10 V 2 %; Imax = 2 mA

mA)

Operational

U > 16 V; 50 mA (with a fault: U < 1 V; Ri = 10 k)

Controlled voltages

U 10 V 2 %; 25 mA; short circuit-proof

Current output stage


Measurement sockets

I 0 to 2.5 A; short circuit-proof; clocked approx. 5 kHz


Command value signal
Actual value signal

10 V 2 %; Imax = 2 mA
2.5 V 2 %; Imax = 2 mA (mV

mA)

149
Hydraulics Bosch Rexroth AG

RE 30110/06.05 VSPA2-1-2X

7/10

Technical data (continued)


Clock frequency
WRA6

f 300 to 370 Hz (at 24 V UB and 0 V Ucom. = 370 Hz)

WRA10

f 180 to 410 Hz (at 24 V UB and 0 V Ucom. = 410 Hz)

WRZ

f 170 Hz

Connection type

48-pin blade connector, DIN 41612, form F

Card dimensions

Eurocard 100 x 160 mm, DIN 41494

Front plate dimensions


Height

3 HE (128.4 mm)

Width soldered side

1 TE (5.08 mm)

Width component side

3 TE

Permissible operating temperature range

0 to 50 C

Storage temperature range

25 C to +85 C

Weight

m 0.17 kg (net)

01

Characteristic curves
2500
2250
4WRZ-7X
2000
4WRA-2X

Current in mA

1750
1500
1250
1000
750
500
350
250

100%

80%

60%

40%

20% 2% 2% 20%

Command value in %

40%

60%

80% 100%

150
8/10

Bosch Rexroth AG

Hydraulics

VSPA2-1-2X

RE 30110/06.05

Display / adjustment element T1


J3 ramp time

J8, J9 jump height

0.2 to 50 sec.

4WRA6 and 10 2X

0.02 to 5 sec.

4WRZ 7X

J8

J9

J4 Jump function

J1 inversion

Off

Inverted

On

Not inverted

REXROTH
-1

Gw+ S+ Gw- S-

Zw
w1
w2
w3
w4

J9

J4

J10

Do not adjust!
(ramp time symmetry)

J8

J1

J3
J5

J2

J6

J7

t
Do not adjust!
(bias current)

w
t

VSPA2

LED displays:
Operational (green)

Do not adjust!
(internal reference voltage)

J5, J6 clock frequency


4WRA6 2X

Enable (yellow)

External inversion

Measurement signal

Measurement zero

J6

J2 ramp function

J7 max. current setting

Off

4WRZ 7X

On

4WRA 2X

4WRA10 2X

Measurement sockets:
I, w, t

J5

Universal, 4WRZ
7X

=
=
=

Factory jumper setting


Jumper closed
Jumper open

Potentiometer (partially with LED display):


Zw
w1
w2
w3
w4
t

Zero point alignment


Command value 1
Command value 2
Command value 3
Command value 4
Ramp time

adjustable on the board:


Gw+
Amplitude attenuation for positive command values
Gw
Amplitude attenuation for negative command values
S+
Jump heights for a positive direction
S
Jump heights for a negative direction
f
Clock frequency output stage

Adjusting the locked potentiometers invalidates any guarantee claims!

151
Hydraulics Bosch Rexroth AG

RE 30110/06.05 VSPA2-1-2X

9/10

Display / adjustment element T5


J3 ramp time

J8, J9 jump height

0.2 to 50 sec.

4WRA6 and 10 2X

0.02 to 5 sec.

4WRZ 7X

-1 4Q T

J9

J4 jump function

J1 inversion

Off

Inverted

On

J4

Not inverted

Do not adjust!
(ramp time symmetry)

J8

J1

J3

J2

J6

J7

012

Do not adjust!
(bias current)

789A

VSPA2

LED displays:
Operational (green)

Do not adjust!
(internal reference voltage)

J5, J6 clock frequency


4WRA6 2X

Enable (yellow)

01

J5

w
v

J10

34 56

BC D

J9

Gw+ S+ Gw- S-

Zw
w1
w2
w3
w4
t1
t2
t3
t4
t5
EF

J8

External inversion

Measurement signal

Measurement zero

J6

J2 ramp function

J7 max. current setting

Off

4WRZ 7X

On

4WRA 2X

4WRA10 2X

Measurement sockets:
I, w, t

J5

Universal, 4WRZ
7X

=
=
=

Factory jumper setting


Jumper closed
Jumper open

(detailed information see


RE 30110-B)
Potentiometer (partially with LED display):
Zw
w1
w2
w3
w4
t1
t2
t3
t4
t5

Zero point alignment


Command value 1
Command value 2
Command value 3
Command value 4
Ramp time 1
Ramp time 2
Ramp time 3
Ramp time 4
Ramp time 5

adjustable on the board:


Gw+
Amplitude attenuation for positive command values
Gw
Amplitude attenuation for negative command values
S+
Jump heights for a positive direction
S
Jump heights for a negative direction
f
Clock frequency output stage

Adjusting the locked potentiometers invalidates any guarantee claims!

152
10/10

Bosch Rexroth AG

Hydraulics

VSPA2-1-2X

RE 30110/06.05

Unit dimensions (nominal dimensions in mm)


T1

T5
REXROTH
-1 4Q T

Zw
w1
w2
w3
w4
t1
t2
t3
t4
t5

3HE (128,4)

Zw
w1
w2
w3
w4

t
BC D

012
34 56

EF

89

-1

100

REXROTH

789A

w
t

VSPA2

w
v

VSPA2

4TE (20)

2
7

165

Engineering / maintenance guidelines / additional information


For further information see Product description and commissioning instructions VT-VSPA2-1-2X/ (RE 30110-B).

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

153

RE 29955/09.04
Replaces: 11.02

Electrical amplifier for flow


control with proportional
valves

1/6

Type VT 5035

Component series 1X

H/A/D 5581/96

Table of contents

Features

Features

Ordering code

Functional description

Technical data

Block circuit diagram and pin assignment

Indicator / adjustment elements

Engineering / maintenance notes / supplementary information 5


Unit dimensions

Card holder:
Type VT 3002-2X/32, see RE 29928
Single card holder without power supply unit
Power supply unit:
Type VT-NE30-1X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 70 VA

VT 5035 amplifiers are used for adjusting the flow of variable displacement pumps of types A4VSO and A4VSG (see RE 92050,
RE 92076 and RE 92100).
Features:
Differential input
Enable input with LED indicator lamp
"Ready for operation" signalled by LED
Ramp generator
Four command values that can be adjusted by means of a
potentiometer; call-up is signalled by LEDs
Controller for swivel angle
Two clocked current output stages
Oscillator and demodulator for inductive position measurement
with cable break detection
Reverse polarity protection for power supply
Note:
With the factory setting, the amplifiers have a ramp time of 5 s
(for setting the ramp time to 1 s, see page 5).

Ordering code
VT 5035
Amplifier for the flow adjustment of A4VSO and
A4VSG variable displacement axial piston pumps

1X

*
Further details in clear text

1X =

Component series10 to19


(10 to 19: unchanged technical data and pin assignment

154
2/6

Bosch Rexroth AG

Industrial Hydraulics

VT 5035

RE 29955/09.04

Functional description
Command value inputs 1 to 4 can be used for calling command values [1] by operating the associated relays (K1 to K4).
The command value voltage is provided either directly through
the regulated 9 V voltages of the internal power supply unit
[10] or via an external command value potentiometer. The following is valid for these inputs: 9 V 100 % 1). If these four
command value inputs are connected directly to the regulated
9 V voltages, four different command values can be set using potentiometers "w1" to "w4". If external potentiometers are
used at these inputs, the internal potentiometers act as attenuators or limiters, unless they are set to maximum.
External command vale potentiometers
14c (14a, 20a, 20c)
5K

24a

9V

26c

M0

Inputs

5K

26a

+9V

26c

M0

Inputs

28c
14c (14a, 20a, 20c)
5K

26a

+9V

24c

9V

500 K

8a
10a

Ramp "adjustable"

28c

8a
10a

Ramp "ON/OFF"

Note:
When an external time potentiometer is used, the internal potentiometer for the ramp time must be set to maximum. The
maximum ramp time shortens, because the resistance of the
external potentiometer is connected in parallel to that of the internal potentiometer (ca. 500 k)!
The ramp time can be set to its minimum value (approx. 30 ms)
by operating relay K5 or by means of an external jumper.

28c
14c (14a, 20a, 20c)

External time potentiometer and ramp "OFF"

Inputs

28c

LEDs "H1" to H4 signal, which command value is being


called up. If more than one command value is called at a time,
the input with the highest number has priority.
Example: If command value 1 and command value 3 are activated simultaneously, command value 3, command value 3 becomes effective.
A further output of the card provides a supply voltage for the
command value call-ups, which can be changed over from
+ 9 V to 9 V by means of relay K6 1).
All of the relays on the card are switched with 24 VDC
(smoothed).
Command value input 5 is a differential input (0 to 10 V). If
the command value is provided by external electronics with
another reference potential, this input must be used. When
switching the command value voltage on or off, care must be
taken to ensure that both signal cables are always disconnected from or connected to the input.
Before being passed on, all command values are summated [3]
with the correct amount and sign.
The downstream ramp generator [4] creates a ramp-shaped
output signal from a step-like input signal. The time constant of
the output signal can be adjusted by means of potentiometer
"t". The specified ramp rime refers to a command value stepchange of 100 % and can be approx. 1s or 5 s depending on
the jumper setting (J5, J6). If a command value step-change of
less than 100 % is applied to the input of the ramp generator,
the ramp time shortens accordingly.

The output signal of the ramp generator [4] is the swivel angle
command value and is fed to the PID controller [5], measuring
socket "w" on the front panel of the card and connection 4a
(command value after ramp / external limiting potential). A voltage of 6 V at command value measuring socket "w" corresponds to a command value of + 100 %.
The PID controller is optimised specifically to the requirements
of pump types A4VSO and A4VSG. The current output stages
are controlled in dependence upon the difference between the
swivel angle command value and the actual swivel angle value.
A positive command value signal at the input of the amplifier
activates the output stage for solenoid a, a negative command value signal the output stage for solenoid b.
The inductive position transducer [11] acquires the swivel angle
of the pumps swashplate. The AC voltage signal provided by
the position transducer is converted by oscillator/demodulator
[9] and fed back to the PID controller as actual swivel angle
value.
The zero point of the position transducer (actual value zero
point) can be adjusted by means of potentiometer "Zx" (on the
printed circuit board). The gain of the actual swivel angle value
is calibrated in the factory and must not be changed ( 6V
max. swivel angle).
A signal of > 8.5 V applied to the enable input enables the output stages (indicated by yellow LED "H11" on the front panel).
The output stages can also be enabled permanently independently of the state of the enable input by setting jumper J7. The
enable input then becomes ineffective.
LED "H12" (ready for operation) is on during trouble-free operation; positively, when:
the enable signal is applied,
the internal 9 V voltage supply is operable (amplitude and
symmetry),
there is no short-circuit of the solenoid cables and
no cable break of the position transducer cables.
In the event of a fault, both output stages are immediately deenergised, the controller is switched off and the signal ready
for operation is reset. After rectification of the fault, the card is
immediately operable; LED "H12" is again ON.
1)

= Reference potential for command values 1 to 4 is M0


(measurement zero).

[ ] = Cross-reference to block circuit diagram

155
RE 29955/09.04

Industrial Hydraulics Bosch Rexroth AG

VT 5035

3/6

Technical data (for applications outside these parameters, please consult us!)
UO 24 VDC + 40 % 5 %

Operating voltage
Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 22 V
PS < 50 VA

Power consumption
Current consumption

I <2A

Fuse

IF 2.5 A T

Inputs:
Command values 1 to 4

Ui 9 V (reference potential is M0)

Command value 5

Ui 0 to 10 V

Enable
active

UE > 8.5 V

not active

UE < 6.5 V

01

Relay data:
Nominal voltage

U Operating voltage UO

Response voltage

U 16.8 V

Release voltage

U 2.4 V

Coil resistance

R 2150

Ramp time (adjustment range)

t 30 ms to approx. 1 s or 5 s ( 20 % each)

Outputs:
Output stage
Imax 1.8 A 20 %; R(20) = 5.4

Solenoid current / resistance


Clock frequency

f Freely clocking up to approx. 1.5 kHz

Driver for inductive position transducer


Oscillator frequency
Max. load carrying capacity
amplitude (Uss)

f 2.5 kHz 10 %
Voltage

Regulated voltage

I 30 mA
Ua 5 V per output
U 9 V 1 %; 25 mA externally loadable

Measuring sockets
Command value "w"

Uw 0 to 7

6 V ( 6 V

+ 100 %; + 6 V

100 %); Ri = 100

Actual swivel angle value "x"

Ux 0 to 6

6 V (+ 6 V

+ 100 %; 6 V

100 %); Ri = 100

Type of connection

32-pin male connector, DIN 41 612, form D

Card dimensions

Euro-card 100 x 160 mm, DIN 41 494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side

7 TE

Permissible operating temperature range

0 to 50 C

Storage temperature range

25 to + 85 C

Weight

m 0.15 kg

Note:
For details regarding enivironment simulation testing in the
fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 30095-U (declaration on environmental compatibility).

9V

Auxiliary voltage

12c

= Command value
potentiometer
= Ramp time

K6

= Call-up relay

K5

H4

H3

H2

H1

K1 to K6

K4

R1 to R4

K3

K6

K4

w4
(R4)

= LED for command


value call-ups

K2

K2

K3

w3
(R3)

H1 to H4

K1

K1

w2
(R2)

2
u

J5, J6

K5

10

2200 F

H10

5 Swivel angle controller

13 Proportional valve

12 Swivel angle acquisition

4 Ramp generator
6 Current regulator

11 Position transducer

10 Power supply unit

28a

22a

22c

28c

30c

10c

8c

4a

4c

32a

2a

32c

2c

Operating
voltage

J7: "enable" internal

11

valid for clockwise


rotating pump
( ) valid for counterclockwise rotating
pump

Note on the connection of


the position transducer:

0V

+ UB

Enable input

0V

1 (2)

1 1 (1)

21( )

Command value after ramp 0 to 7 6 V

Actual swivel angle


value 0 to 6 6 V

Solenoid "a"

13

Solenoid "b"

VT 5035

3 Summator

9 Oscillator/demodulator

J7

Zx

2 Differential amplifier

8 Monitor

7 Output stage

2,5 A T

12

Gx

12

PID

PI

PI

1 Command values

Enable

F = on front panel

Ready for
operation

Industrial Hydraulics

A positive command value at the input


(corresponds to negative command
value at measuring socket "w") causes an intensification of the current in
solenoid "a".
A negative command value at the
input (corresponds to positive command value at measuring socket "w")
causes an intensification of the current in solenoid "b".

Measurement zero (M0) is + 9 V 26a


raised by 9 V as against 0V M0 26c
24a
9V
operating voltage!

24c

18c

18a

16c

16a

12a

w1
(R1)

30a

14c

14a

20a

20c

6c
6a

10a

+ 100 %

Measuring socket "x": + 6 V

Bosch Rexroth AG

Call-up of comm. value 1


Call-up of comm. value 2
Call-up of comm. value 3
Call-up of comm. value 4
Call-up "ramp OFF"
Call-up "change over
auxiliary voltage" relay
call-up voltage (+ 24 V)

9V

9V

9V

Command value 4
Command value 3
Command value 2
Command value 1

9V

Differential input:
Reference potential/GND
Command value 5 10 V

External ramp

8a

+ 100 %

Measuring socket "w": 6 V

4/6

156
RE 29955/09.04

Block circuit diagram / pin assignment: VT 5035 (series 17 or higher)

157
RE 29955/09.04

Industrial Hydraulics Bosch Rexroth AG

VT 5035

5/6

Indicator / adjustment elements


Zx: Position transducer zero point

Max. ramp time


approx.1 s or 5 s
H10 - red LED "cable break"

w1/H1 - command value 1 with LED indication


w2/H2 - command value 2 with LED indication
w3/H3 - command value 3 with LED indication
w4/H4 - command value 4 with LED indication

J6
w1

J5

w2
X1

LED "enable" (yellow)


LED "ready for operation" (green)

Gx: Gain of actual swivel


angle value (factory-calibrated)

w3
w4

F1
2,5 A T

- ramp time

- measuring socket for actual swivel


angle value

- measuring socket for command


value

01
J7

Enable
Meaning of the jumpers on the card for settings

Note:

(nameplate on the back of the front panel)

The circles (
the customer.

ramp time
5 s J5 J6
1 s J5 J6

Ramp time

enable
int. J7
ext. J7

Enable

Jx = bridge
Jx = open
= delivery state

) denote the settings made by

Jumper plugged
or

Jumper
open

Factory setting

Engineering / maintenance notes / supplementary information


The amplifier card may only be plugged or unplugged when disconnected from the power supply!
Do not use plugs with free-wheeling diodes or LEDs for connecting the solenoids!
Measurements on the card may only be taken with instruments with Ri > 100 k!
The measurement zero (M0) is raised by + 9 V as against 0V operating voltage and is not electrically isolated, i.e. 9 V regulated voltage 0V operating voltage. The measurement zero (M0) must therefore not be connected to the 0V operating voltage!
Use relays with gold-plated contacts for passing on command values (small voltages, small currents)!
Use only switching contacts with a load carrying capacity of approx. 40 V, 50 mA for switching the card relays!
In the case of external controlling, the control voltage may have a maximum residual ripple content of 10 %!
Always shield the command value cables and inductive position transducer cables separately; connect the shield to 0V operating voltage on the card side and leave the other end open (risk of earth loops)!
Recommendation: Shield also solenoid cables!
For solenoid cable lengths up to 50 m use cable type LiYCY 1.5 mm2. For greater lengths, please consult us!
The distance to aerial lines, radio sources and radar equipment must be at least 1 m!
Do not lay solenoid and signal cables near power cables!
Due to the charging current of the smoothing capacitor on the card, back-up fuses must have slow-blowing characteristics!
Do not connect the ground symbol on the inductive position transducer to ground!
(Precondition for compatibility with preceding series!)
Caution:

When using the differential input, both inputs must always be switched on or off simultaneously!

Note:

Electrical signals brought out via control electronics (e.g. actual value) must not be used for switching safety-relevant machine functions!
(See also European standard "Safety requirements for fluid power systems and components - hydraulics", prEN 982)

158
6/6

Bosch Rexroth AG

Industrial Hydraulics

VT 5035

RE 29955/09.04

Unit dimensions (dimensions in mm)

89

100

3HE (128,4)

H
t
x
w
: M0
6 V: 100 %

8TE (40,3)

2
7

165
180

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengiesser 1
97816 Lohr am Main, Germany
Telephone +49 (0) 93 52 / 18-0
Fax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

159

RE 29 957/07.03
Replaces: 06.90

Electronic Amplifier
Type VT 5036
for Setting the Output Flow
of Axial Piston Pumps A10VSO
F 87018

Series 1X

01
Type VT 5036 S 1X

Overview of contents
Description
Features
Technical Data
Terminal Connection
External command level potentiometer /
External ramp time potentiometer
Functional description
Ordering code
Additional information
Unit dimensions

Features
Page
1
2
3
4
4
5
5
5

Amplifier VT 5036 S1X is used for setting the output flow of


axial piston pumps type A10VSO.
Smoothing circiut
Voltage stabilisation
Self pulsing output stages
Oscillator and demodulator for inductive positional feedback
PD regulator
1 relay for ramp "off"
Ramp generator
Summator
Cable break detector with LED indicator
Differential amplifier input
Suitable card holders are:
VT 3002-1X see RE 29 916
VT 1516-1X see RE 29 915
VT 1700-1X see RE 29 917

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by any means, without the prior written authorisation of Bosch Rexroth AG.
In the event of contravention of the above provisions, the contravening party is obliged to pay compensation.

VT 5036

1/6

RE 29 957/07.03

160

Technical data (For applications outside these stated values, please consult us!)
Ueff:

Power supply
Full bridge rectification
3-phase bridge rectification

24 V 10 %
28 V to 35 V

Regulated voltage

U:

9 Vwith centre tapping

Max. load of regulated voltage

R:

500

Max. load resistande of selenoid

R:

12

Imax:

Max. output current

700 mA

Output current at rest

I:

approx. 400 mA

Power requirements

P:

20 VA

Oscillator frequency

f:

~ 2,5 kHz

Frequency (output stage)

f:

250 Hz

Fuse

I S:

2,5 Ampere M

Perm. ambient temperature

t:

0 to 50 C

Dimensions
Space required

Weight

RE 29 957/07.03

100x160 mm EUROPA-Format to DIN 41 494


Conductor side
Component side

1 division
7 divisions
1 div. 5,08 mm

m:

0,15 kg

2/6

VT 5036

VT 5036

3/6

Supply voltage

0V

+ 24V

+ 24 V

10ac

6ac

8ac

d1

P1 = Ramp time "up"


P2 = Ramp time "down"

Relay selection voltage

24c

L0

2,5 A

D1

P1 P2

d1

P3 = Gain
d1 = Relay selection

11

14ac
9V
18ac
M0
16ac
+9V
28a

Reference potential

+ 10 V

22a

24a

value

Differential amplifier input:

26c

Displacement command

32c

30c

Ramp
"Off"

Actual value
0 to 6 V

BU1

BU2

P3

PD

3a

10

~
~

~
~

3b

3c

1
2
3
4
5
6

Ramp generator
PD regulator
Pulsed output stage
Oscillator
De-modulator
Matching amplifier

7
8
9
10
11

L0

Cable break detector


Power section
Positional transducer
Cable break LED
Differential amplifier

Measured 0 (M0) is raised to + 9 V above 0 volts (0V)


with respect to the supply voltage!

L0

LED lights to indicate


cable breaks

Command value
0 to + 6 V

12c

14c

20c

22c

4ac

2ac

IW9

L0

14c
12c

20c

22c
IW9

Note:
For anticlockwise pump
rotation, connect up
according to lower diagram!

161

Terminal Connection VT 5036 S1X

RE 29 957/07.03

01

162

External command level potentiometer

External ramp time potentiometer

500 K

30c
32c

+ 9 V:
5K

26c
18ac

Ramp externally
"adjustable"

30c

16ac

Ramp "off"
32c

Note:
When using an external ramp time potentiometer in the internal ramp
time potentiometer must be set to maximum!

Functional Description
Amplifier type VT 3056 S1X has 4 command level inputs refered to
potential M0, and one differential amplifier input (terminals 22a and
24c).
One command level input may have a maximum voltage of + 9 V. The
second command level input has a maximum voltage of + 6 V.
The + 9 V command level input can be connected directly to the
measured voltage + 9 V of the power supply section (8), or via an
external command level potentiometer.
If the command level voltage comes from an external source, the
differential amplifier input (11) must be used. When using the
differential amplifier input (11) it is important to ensure that the two
signal lines are connected or separated simultaneously from the
inputs when signalling the command level voltage.
The ramp generator (1) converts a stepped input signal into a slowly
rising or falling output signal. The ramp generator forms a slowly
rising or falling output signal from a stepped input signal. The rise and
fall times (gradient) of the output signal is settable at potentiometers
P1 and P2.
The ramp time can achieve a maximum value of 5 s over the full
voltage range (from 0 to 6 V, measured at the command value test
points). If a smaller command value that 9 V is applied to the input
of the ramp generator (1), the ramp time will be shortened.
The output signal of the ramp generator (1) is passed to the PD
regulator (2).

RE 29 957/07.03

The oscillator (4) converts a DC signal voltage to an alternating


voltage. This signal is then passed to the inductive positional transducer.
The positional transducer (9) alters the voltage level of this alternating
voltage signal dependent upon the swivel angle of the pump. This
alternating voltage signal is then reconverted into a DC signal in the
demodulator (5).
The level of this DC voltage is proportional to the swivel angle.
The matching amplifier (6) can be used to vary this actual value. As
the output signal of the matching amplifier (6) is the actual value of
the PD regulator (2), the maximum stroke can be varied by means of
potentiometer P3.
The PD regulator (2) and the pulsed output stage (3), which consists
of current regulator (3a), pulsed generator (3b) and the power
amplifier (3c), are specially matched to the axial piston unit.
Dependent on the difference between the command and actual value,
the PD regulator send out a signal which controls the self pulsing
output stages (3).
The cable break detector (7) monitors the leads to the inductive
positional transducer (9) and should an error occur switches off both
solenoids. Simultaneously, an LED (10) on the front plate of the
amplifier indicates "cable break".

4/6

VT 5036

163

Ordering code
VT 5036

S 1X / R5

*
further details in clear text

32 pin edge connector to DIN 41 612 form D


=S
(for installation in an Euro card magazine and card holder)
series 10 to 19
(10 to 19: installation details remain unchanged)

no code =
E=
= 1X

German front plate


English front plate

R5 =

ramp 5 s max.

Additional Information
The amplifier may only be unplugged when switched off!
Measurements to be made with a high resistance meter set on the voltage range!
Measured (control) zero (M0) is raised + 9 V with respect to 0 V of the power supply!
M0 may NOT be connected to 0 V at the power supply!
The "earth" sign of the inductive positional transducer may NOT be connected to (0V) of the supply voltage!
Radio tranmitters may not be placed within 1 m of this card!
Command level inputs my only be switched with contacts suitable for currents of > 1 mA!
Screen all input lines. Leave one end of the screen open. Connect one end to 0 V of the supply line!
Do not lay solenoid lines close to power lines!
When using the internal relays, terminal 28c must be used as the power supply line!

01

Unit dimensions (Dimensions in mm)


REXROTH

Window for card place in Euro card magazine

prop. amplifier
cable break
off Ramp
on

128

Istwert
Sollwert

LED indicator for cable break


Ramp "off" "on"
Test point 1: Measured of actual value voltage 0 6 V
Test point 2: Measured of command value voltage 0 + 6 V

up
ramp time
down

Ramp time setting "up" "down" from 0,03 to 5 s

R5

VT
5036

128
40

15

172
186

172

2,5

11

VT 5036

89
100

5/6

RE 29 957/07.03

164

Notes

Bosch Rexroth AG
Industrial Hydraulics

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application
can be derived from our information.The details
stated do not release you from the responsibility
for carrying out your own assessment and
verification. It must be remembered that our
products are subject to a natural process of
wear and ageing.

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 29 957/07.03

6/6

VT 5036

165

Electrical amplifier
for the control of servo valves
with electrical position feedback

RE 29979/07.05
Replaces: 11.02

1/6

Type VT-SR1

Series 1X

Table of contents

Features

Features

The amplifier VT-SR1 is suitable for the control of 2-stage servo


valves with electrical position feedback (type 4WS2EE ).

Ordering code

Valve current controller

Function

Main spool position controller

Technical data

Dither signal generator

Block circuit diagram / connection allocation

Inverse pulsed output stage

Engineering / maintenance guidelines / additional information

Oscillator/demodulator

Unit dimensions

Enable circuit using relays

Contents

Page

Measuring instrument for displaying the servo valve current


Polarity protection for the supply voltage
Optional accessories:
PID controller 1) with controller switching
Relay with a potential free 2-way contact (28 V / 2 A)
Voltage controller 15 V for the controller and
position transducer electronics
1)

The D component only acts on the actual value


(velocity feedback).

166
2/6

Bosch Rexroth AG

Hydraulics

VT-SR1

RE 29979/07.05

Ordering code

VT

SR1

1X

*
Further details in clear text 2)

Amplifier for servo valves with electrical position


feedback; type 4WS2EE (all nominal sizes)
Series 10 to 19
(10 to 19: unchanged technical data
and connection allocation)

Valve type code


= 1X

0=
1=

Without 15 V voltage controller


With 15 V voltage controller

2) E.g. With/without PID controller, with/without


reserve relay K3
Suitable card holders:
Type VT 3002-2X/32, see RE 29928
Single card holder without power supply

For the additional PID controller, the controller technical


data must be stated.

Suitable power supply:


Type VT-NE31-1X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 7 VA

Function
The amplifier VT-SR1 operates using an inverted pulse output
stage with bipolar transistors. The output from this output stage may be switched on and off by means of an enable circuit
(relay K2). The enable is indicated by the lighting up of LED
H2 on the front plate. The switching voltage for all relays is
set to either 0 V or +UB using jumpers J12 and J13 (works
setting +UB).

The necessary symmetrical operating voltage UB is protected


against reverse polarity. If the card does not include a voltage controller to supply the closed loop controller and position
transducer electronics, then an additional stabilised auxiliary
voltage UM must be available. The auxiliary voltage connection is protected against reverse polarity up to a maximum
current of 1 A.

The output stage comprises of an I controller with connected


dither signal generator. The amplitude of the dither signal is
set using R7. A PD controller is used to control the pilot stage
(command value current). The actual value current feedback is
displayed at the same time by the instrument on the front plate.

The amplifier may be optionally equiped with a PID controller


(the D component only effects the actual value signal) with selectable PI component and a reserve relay with a potential free
2-way switch. Using this controller, an additional closed loop
control circuit (e.g. for a closed loop drive control) may be superimposed. The P and D components may be set on the front
plate. The switched status of the controller is displayed by LED
H1 and the relay by LED H3 (the LEDs lights up when the
relay is closed). The PID controller is set up in accordance with
the customer specifications and hence must be stated in clear
text on the order. These amplifiers are allocated a special type
code on delivery. The reserve relay may be loaded up to 28 V
and 2 A.

The oscillator/demodulator is used to determine the spool


position. It is designed as a plug-in card. The parameters of
which are matched to the corresponding valve type.
The command value position and the actual value position are
fed to the PD controller. The D component only effects the
actual value (velocity feedback).
The zero point may be set on the front plate by means of R3
(NP).

167
RE 29979/07.05

Hydraulics Bosch Rexroth AG

VT-SR1

3/6

Technical data (for applications outside these parameters, please consult us!)
Operating voltages:
UB 24 VDC

With voltage controller


Upper limiting value

uB(t)max 28 VDC

Lower limiting value

uB(t)min 22 VDC

Without voltage controller

UB; UM 24 VDC; 15.0 VDC

Upper limiting value

uB(t)max; uM(t)max 28 VDC; 15.2 VDC

Lower limiting value

uB(t)min; uM(t)min 22 VDC; 14.8 VDC

Current consumption (without valve) at UB = 24 V 1)

I < 150 mA

Inputs:
Command value 1 (main spool position)

Ue 0 to 10 V (Re = 50 k)

Command value 2 (main spool position) with J9

Ue 0 to 10 V (Re = 50 k)

Actual value (main spool position)

Ue 0 to 10 V (Re = 50 k)

Enable

Ue +24 V with J13; 0 V with J12 (Re = 700 ; relay circuit)

Controller switching

Ue +24 V with J13; 0 V with J12 (Re = 700 ; relay circuit)

Reserve relay

Ue +24 V with J13; 0 V with J12 (Re = 700 ; relay circuit)

Outputs:
Stabilised output voltage 1)

UM 15 V 2 %; 150 mA

Valve current

Imax 60 mA
+60 mA (measuring output)
Ua 10 V =
U +24 V (+UB)

Command value valve current (with J10)


Relay selection voltage
Dither signal

f 340 Hz 5 % (ISS = 3 mA)

Oscillator frequency

f 2.5 kHz / 5 kHz (dependent on the valve type)

Relay data:
Nominal voltage

U +26 V

Response voltage

U > 13 V

Release voltage

U 1.3 V to 6.5 V

Switching time
Coil resistance (at 25 C)

t < 4 ms
R 700

Connection type

32-pin blade connector, DIN 41612, form D

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width, conductor side

1 TE (5.08 mm)

Width, component side

7 TE

Permissible ambient temperature range

J 0 to +50 C

Storage temperature range

J 20 to +70 C

Weight

1)

In version with voltage controller

m 0.3 kg

01

16a

28c

30c

6c

2a

Operating voltage
22 to 28 VDC

UB

+ UB

1)

R65

R13

+ UB

R2
P

PID

R1

K1

UB

J12

Controller
+15 V

UDSS

R7

H3

6 F

K3

K3

K2

M0

4a

4c

2c

6a

12c

8a

10a

8c

10c

32a

16a

18ac

F = On front panel

J13

2 F

H2

16a

24c

24a

+UB ( with J12)

+UB ( with J12)

15 V ( UM)

M0

+ 15 V (+ UM)

Max.
contact loading:
U = 28 V
I=2A

Reserve

Position actual value

Enable

Valve 4WS2EE

D C

B E

Hydraulics
VT-SR1

Without R13 and by fitting J14 and R65


the controller input becomes a differential input.

UB

Controller
15 V

22c

H1

K2

26c

26a

20c

J14

K1

DV F

PD

18c

J6

R3

NP

Valve current
IX / %

16c

14c

Controller output 1)
32c
(differential amplifier output)

Actual value 1)
(reference potential)

Command vlaue

Controller
switchover
+UB ( with J12)

J9

+ UB = 24 V

J10

Bosch Rexroth AG

Call-up voltage for


Relays K1, K2, K3 14a

Position command value 1

30a

Position command value 2 (J9)


28a
or
Controller output (J10)

4/6

168
RE 29979/07.05

Block circuit diagram / connection allocation

169
Hydraulics Bosch Rexroth AG

VT-SR1

RE 29979/07.05

5/6

Engineering / maintenance guidelines / additional information


The amplifier card must only be removed or inserted when de-energised!
Command value signals must only be switched using relays with gold plated contacts
(small voltages, small currents)!
Only use contacts with a loadability of approx. 40 V; 50 mA for switching card relays (enable, controller switching, reserve).
Always screen the command and actual value cables; leave one end of the screen open, connect on the card side to ground ()!
Do not lay signal cables in the vicinity of power cables!
1. Also screen the solenoid cables (connect one end to )!
2. Use cable type LiYCY 1.5 mm2 for lengths up to 50 m long. Longer lengths on request!

Recommendations:

Note:

Electrical signals (e.g. actual value) taken via valve electronics must not be used to switch off
the machine safety functions!
(This is in accordance with the regulations to the European standard Safety requirements of fluid
technology systems and components - hydraulics, prEN 982.)

01

Unit dimensions (dimensions in mm)

Rexroth

P
D

89

H3

100

H2

IX / %

3HE (128,4)

H1

NP
DV
2
4
6

VT-SRXX

1
3
5

8TE (40,3)
7

165
182

170
6/6

Bosch Rexroth AG

Hydraulics

VT-SR1

RE 29979/07.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

171

RE 29980/09.05
Replaces: 02.03

Analogue amplifier

1/6

Type VT-SR2

Series 1X

H5658

Features

Table of contents
Contents

Page

Features

Ordering code

Functional description

Technical data

Block circuit diagram / pin assignment

Unit dimensions

Engineering / maintenance notes / supplementary information 5

Suitable for controlling single and two-stage servo-valves


without electrical position feedback (types 4WS2EM 6,
4WS2EM 10., 4WS2EM 16., 4WS2EB 10., 4DS1EO 2 and
3DS2EH 10)
Regulator for valve current
Dither signal generator
Push-pull output stage
Enable circuit with relay
Measuring instrument for displaying servo-valve current
Reverse polarity protection for voltage supply
Optional extensions:
PID-controller1) with controller changeover
Relay with potential-free changeover contact (28 V / 2 A)
Voltage regulator 15 V for supplying the closed-loop
control electronics
1) The D-components act on the actual value only.
Suitable Card holders:
Type VT 3002-2X/32, see RE 29928
Single card holder, without power supply unit
Suitable Power supply unit:
Type VT-NE31-1X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 7 VA

172
2/6

Bosch Rexroth AG

Hydraulics

VT-SR2

RE 29980/09.05

Ordering code

VT-SR2

1X

*
Further details in clear text

Amplifier for servo-valves without electrical position feedback;


types 4WS2EM 6, 4WS2EM 10., 4WS2EM 16.,
4WS2EB 10., 4DS1EO 2 and 3DS2EH 10
Series 10 to 19
= 1X
(10 to 19: unchanged technical data and pin assignment)
Without voltage regulator 15 V
With voltage regulator 15 V

60 =

Valve current:
60 mA

100 =

100 mA

=0
=1

Functional description
VT-SR2 amplifiers operate with a push-pull output stage with
bipolar transistors. The output of this output stage can be activated or deactivated using an enable circuit (relay K2). The
enable is indicated by lighting up of the LED H2 on the front
panel. The switching voltage of all relays is set to either 0 V or
+UO (factory setting +Uo) by means of jumpers J12 and J13.

The required symmetric operating voltage UO is protected


against reverse polarity. For the version without voltage regulator, an additional stabilised auxiliary voltage (UM) must
be provided to supply the controller electronics. The auxiliary
voltage connection is protected against reverse polarity up to a
maximum current of 1 A.

The output stage consists of an I-controller with connected


dither signal generator. The amplitude of the dither signal can
be adjusted using R7. The input stage (current command value)
is controlled by a PD-controller. The actual current value fed
back is indicated on an instrument on the front panel.

Optionally, the amplifier can be fitted with a PID-controller


(D-component acts only on the actual value), with the PI-component being able to be changed over, and a reserve relay with
potential-free changeover contact. This controller can be used
to superimpose a further closed control loop (e.g. for drive control). The P- and D-component can be adjusted on the front panel. The control state of the controller is signalled by LED H1,
that of the relay by LED H3 (LEDs light up when relays are
picked up). The PID-controller configuration is customised and
must therefore be indicated in clear text on the order. When
dispatched, a special type designation is assigned to the amplifier. The reserve relay may be loaded up to 28 V and 2 A.

The position command value is fed to the PD-controller, with


the D-component acting only on input 3.
The valve zero point can be adjusted from the front panel using
R3 (NP).

173
RE 29980/09.05

Hydraulics Bosch Rexroth AG

VT-SR2

3/6

Technical data (for applications outside these parameters, please consult us!)

Operating voltages
UB 24 VDC

With voltage regulator


Upper limit value

uO(t)max 28 VDC

Lower limit value

uO(t)min 22 VDC

Without voltage regulator


(operating and auxiliary voltage)

UO

UM

24 VDC

15.0 VDC

Upper limit values

uO(t)max

uM(t)max 28 VDC

15.2 VDC

Lower limit values

uO(t)min

uM(t)min 22 VDC

14.8 VDC

1)

I <150 mA

Power consumption (without valve) at UO= 24 V


Inputs
Command value 1 (main spool position)

Ue

0 to 10 V (Ri = 50 k)

Command value 2 (main spool position) with J9

Ue

0 to 10 V (Ri = 50 k)

Enable

Ue +24 V with J13

0 V with J12

(Ri = 700 , relay circuit)

Changeover of controller

Ue +24 V with J13

0 V with J12

(Ri = 700 , relay circuit)

Reserve relay

Ue +24 V with J13

0 V with J12

(Ri = 700 , relay circuit)

01

Outputs
Regulated output voltage 1)

UM 15 V 2 %, 150 mA

Valve current

Imax 60 mA / 100 mA

Valve current command value (with J10)


Relay call-up voltage
Dither signal

Ua 10 V +60 mA / +100 mA (measurement output)


U +24 V (+UO)
f 340 Hz 5 % (ISS = 3 mA)

Relay data
Nominal voltage

U +26 V

Response voltage

U >13 V

Release voltage

U 1.3 V to 6.5 V

Switching time
Coil resistance (at 25 C)

t <4 ms
R 700

Type of connection

32-pin male connector, DIN 41612, form D

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side

7 TE

Permissible ambient temperature range

0 to +50 C

Storage temperature range

20 to +70 C

Weight

m 0.2 kg

1)

Only for version with voltage regulator

28a

16a

1)

UB

+ UB

J14

R65

R13

UB

+ UB

R2

PID

R1

K1

R7

Volt. reg.
15 V

UB

J12

= UDSS

Volt. reg.
+15 V

H1

The controller input can be converted into


a differential input by removing R13 and
plugging in J14 and R65.

K1

DV F

PD

R3

J13

K3

K3

K2

22c

18c

12c

32c

8a

10a

8c

10c

6a

16a

24a
24c

F = on front panel

H3

H2

K2

26c

26a

+UO ( with J12)

15 V ( UM)

M0

+ 15 V (+ UM)

Regulated output voltage


(for version with voltage regulator)
or
input for auxiliary voltage
(for version without voltage regulator)

Controller output 1)

I =2A

U = 28 V

+UO ( with J12)

max. contact load:

Reserve

Enable

Servo-valve

VT-SR2

1)

20c

16c

14c

28c

30c

6c

2a

J6

+ UB = 24 V

J9

NP

Valve current
IX/%
F

Hydraulics

22 to 28 VDC

Operating voltage

Actual value
(Reference potential)

1)

Controller input
(differential input)
command value

+UO ( with J12)

Controller changeover

relays K1, K2, K3 14a

Call-up voltage for

Input 3

J10

Bosch Rexroth AG

32a

Position command value 1 30a

controller output (J10)

or

Position command value 2 (J9)

4/6

174
RE 29980/09.05

Block circuit diagram / pin assignment

175
5/6

Hydraulics Bosch Rexroth AG

VT-SR2

RE 29980/09.05

Unit dimensions

(Dimensions in mm)

89

IX / %

3HE (128,4)

H1
H2
H3

100

NP
DV
2
4
6

01
8

1
3
5

VT-SRXX
8TE (40,3)

2
7

165
182

Engineering / maintenance notes / supplementary information


The amplifier may only be plugged or unplugged when disconnected from the power supply!
Command values may only be switched via relays with gold-plated contacts
(small voltages, small currents)!
For switching card relays (enable, controller changeover, reserve) use only contacts with a load-carrying capacity of
ca. 40 V, 50 mA.
Always shield command value and actual value cables; leave one end of shield open and connect the card-sided end to
the ground ()!
Do not lay signal cables near power cables!
Recommendation:

Also shield solenoid cables!


For solenoid cable lengths up to 50 m, use cable type LiYCY 1.5 mm2.
For greater lengths, please consult us!

176
6/6

Bosch Rexroth AG

Hydraulics

VT-SR2

RE 29980/09.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

177

RE 30209/07.04

Electrical amplifier for the control of


high response control valves with a
servo pilot control valve

1/6

Types VT-SR41 to VT-SR43

Series 1X

H5657

Overview of contents

Features

Contents

Page

Features

Ordering details

Function

Technical data

Block circuit diagram / connection allocation

Engineering / maintenance guidelines / additional information

Unit dimensions

Amplifiers VT-SR41 to VT-SR43 are suitable for the control of


high response control valves (flow control valves) with servo valve pilot control and electrical position feedback (cartridge valves,
type .WRC ).
Controller for valve current
Controller for main spool position
Dither signal generator
Inverted pulsed output stage
Oscillator/demodulator
Enable circuit with relays
Measuring instrument for displaying the servo valve current
Polarity protection for the supply voltage
Optional additions:

Card holders:
Type VT 3002-2X/32, see RE 29 928
Single card holder without power supply
Power supply:
Type VT-NE31-1X, see RE 29 929
Compact power supply 115/230 VAC 24 VDC, 7 VA

PID controller 1) with controller switchover


Relay with potential free changeover contact (28 V / 2 A)
Voltage controller 15 V for the supply of the controller and
position transducer electronics
1)

The D component only affects the actual value (velocity feedback).

178
2/6

Bosch Rexroth AG

Industrial Hydraulics

VT SR41 bis VT SR43

RD 30209/07.04

Ordering details
VT SR_ _ 1X
Amplifier for high response control valves
(flow control valves) with servo pilot control
Type .WRC 32
Type .WRC 40
Type .WRC 50
Series 10 to 19
((10 to 19: unchanged technical data
and connection allocation)

*
futher details in clear text 1)
2=
3=

= 41
= 42
= 43
= 1X

0=
1=
1)

for valves with 2/2-way function


for valves with 3/2-way function
Without 15 V voltage controlle
With 15 V voltage controlle

E.g. with/without PID controller, with/without reserve


relay K3
The controller parameters must be specified for the
additional PID controller.

Function
The VT-SR41 to VT-SR43 amplifiers work with an inverted pulse output stage with bipolar transistors. The output from this
output stage can be switched on or off by means of an enable
circuit (relay K2). The enable is indicated on the front plate by
the lightening up of LED "H2". The switching voltage of all the
relays is set to either to 0 V or + UB using jumpers J12 and J13
(+ UB is factory pre-set).
The output stage comprises of an I controller that has a dither
generator connected to it. The amplitude of the dither signal is
set using R7. The pilot stage (command value current) is controlled via a PD controller. The feedback from the current actual
value is simultaneously displayed by the instrument on the front
plate.
The oscillator/demodulator is used to determine the spool position. It is designed as a plug-in card. The parameters of which
are adapted to the corresponding valve type.
The position command value and the position actual value are
passed to the PD controller. The D component only effects the
actual value (velocity feedback).

The zero point may be set on the front plate by means of R3


("NP").
The necessary symmetrical operating voltage UB is protected
against reverse polarity. If the card does not include a voltage
controller to supply the closed loop controller and the position transducer electronics, then an additional stabilised auxiliary
voltage UM must be available. The auxiliary voltage is protected against reverse polarity up to a maximum current of 1 A.
The amplifier may be optionally equipped with a PID controller
(the D component only effects the actual value) with switchable PI component and a reserve relay with a potential free changeover contact. Using this controller, an additional closed loop
control (e.g. for a further closed loop drive control) may be superimposed. The P and D components may be set on the front
plate. The switching state of the controller is displayed by LED
"H1", and that of the relay by LED "H3" (the LEDs lights up
when the relay is closed). The PID controller is set up in accordance with the customer specification and hence must be
stated in clear text on the order. The amplifiers are allocated a
special type code on delivery. The reserve relay may be loaded
up to 28 V and 2 A.

179
RD 30209/07.04

Industrial Hydraulics Bosch Rexroth AG

VT SR41 bis VT SR43

3/6

Technical data (for applications outside these parameters, please consult us!)
Operating voltages:
UB 24 VDC

With voltage controller


-Upper limiting value

uB(t)max 28 VDC

-Lower limiting value

uB(t)min 22 VDC

Without voltage controller

UB; UM 24 VDC; 15.0 VDC

-Upper limiting value

uB(t)max; uM(t)max 28 VDC; 15.2 VDC

-Lower limiting value


Current consumption (without valve) at UB= 24 V

uB(t)min; uM(t)min 22 VDC; 14.8 VDC


1)

< 150 mA

Inputs:
-Command value 1 (main spool position)

Ue 0 bis 10 V (Re = 50 k)

-Command value 2 (main spool position) with J9

Ue 0 bis 10 V (Re = 50 k)

-Actual value (main spool position)

Ue 0 bis 10 V (Re = 50 k)

-Enable

Ue + 24 V mit J13; 0 V mit J12 (Re = 700 ; relay circuit)

-Controller switchover

Ue + 24 V mit J13; 0 V mit J12 (Re = 700 ; relay circuit)

-Reserve relay

Ue + 24 V mit J13; 0 V mit J12 (Re = 700 ; relay circuit)

Outputs:
-Controlled output voltage 1)

UM 15 V 2 %; 150 mA

-Valve current

Imax 60 mA / 100 mA (dependent on the valve size)

-Valve current command value (with J10)


-Relay call-up voltage

Ua 10 V + 60 mA / + 100 mA (measuring output)


U + 24 V (+ UB)

Dither signal

f 380 Hz 5 % (ISS = 0.42 mA)

Oscillator frequency

f 5 kHz

Relay data:
-Nominal voltage

U + 26 V

-Response voltage

U > 13 V

-Release voltage

U 1.3 V to 6.5 V

-Switching time
-Coil resistance (at 25 C)

t < 4 ms
R 700

Connection type

32-pin blade connector, DIN 41 612, form D

Card dimensions

Euro-card 100 x 160 mm, DIN 41 494

Front panel dimensions:


-Height

3 HE (128.4 mm)

-Width, conductor side

1 TE (5.08 mm)

-Width, component side

7 TE

Permissible ambient temperature range

J 0 to + 50 C

Storage temperature range

J 20 to + 70 C

Weight
1)

For version with voltage controller

m 0.3 kg

01

16a

28c

30c

6c

2a

UB

+ UB

R65

R13

UB

+ UB

R2
P

PID

R1

K1

UDSS

UB

J12

R7

Regulator
15 V

Regulator
+ 15 V

H1

removing R13 and fitting J14 and R65 the controller


input is converted into a differential output.

20c

16c

14c

J14

K1

DV F

PD

H3

2 F

H2

6 F

K3

K3

K2

M0

F = on front plate

J13

K2

+ UB (

Max.

Reserved

22c

18c

12c

Valid for valve type 2WRC

red 1 (red)
brown 1(blue)
blue 1(brown)
black 1(black)

Inductive posit.
transducer

with J12)

( ) Valid for valve type 3WRC

E 1 (E)

F 1 (C)

C 1 (F)

D 1 (D)

with J12)

B 1 (C)

A 1 (D)

A negative command value at connection 30a


results in a flow from A to T in the main stage.

A positive command value at connection 30a


results in a flow from P to A in the main stage.

For valve type 3WRC:

A positive command value at connection 30a


results in the opening of the main stage and a
15 V ( UM)
flow from A to B or B to A.

M0

+ 15 V (+ UM)

I=2A

8a U = 28 V

(A)

C 1 (B)

For valve type 2WRC:

+ UB (

Actual position

10a Contact load:

8c

10c

32a

16a

18ac

4a

4c

2c

6a Interlock release

16a

24c

24a

26c

26a

Servo valve

VT SR41 bis VT SR43

1) By

Operating voltage
22 bis 28 VDC

J6

R3

NP

D1

Industrial Hydraulics

(Differential amplifier output)

Regulator output 1) 32c

Actual signal 1)
(referece potential)

Command signal

Regulator switch
+ UB ( with J12)

J9

+ UB = 24 V

J10

"IX / %"

Valve current F

Ventil .WRC

Bosch Rexroth AG

Selection voltage for


Relays K1, K2, K3 14a

Command position 1

30a

Command position 2 (J9)


28a
or
regulator output (J10)

4/6

180
RD 30209/07.04

Block circuit diagram / connection allocation

181
Industrial Hydraulics Bosch Rexroth AG

VT SR41 bis VT SR43

RD 30209/07.04

5/6

Engineering / maintenance guidelines / additional information


The amplifier card may only be plugged or unplugged when switched off!
Command values may only be switched using relays with gold-plated contacts (small voltages, small currents)!
Only use contacts with a load of approx. 40 V; 50 mA for switching the card relays (enable, controller selection switch, reserve).
Screen all actual and command value lines; leave one end of the screen open, connect one end to ground ( )!
Do not lay signal lines close to power lines!
Recommendation: 1. Screen all solenoid lines (connect one end to )!
2. Use cable type LiYCY 1,5 mm2 for lengths less than 50 m long, longer lengths
on request!
Attention: Relay K2 may only be switched off when the servo valve is trimmed so that the main
stage of the WRC valve moves the actuator into a safe end position!
When the servo valve is not trimmed and relay K2 switched off, the position of the control
spool of the main stage is not defined!
Note: Electrical signals (e.g. actual value) taken via the valve electronics must not be used to
switch the machine relevant safety functions!
(Also see the European Standard regulations "Safety requirements of fluid technology systems and
components - hydraulics", prEN 982.)

Unit dimensions

01

(Dimensions in mm)

P
D

89

H3

100

H2

IX / %

3HE (128,4)

H1

NP
DV
2
4
6

VT-SRXX

1
3
5

8TE (40,3)
7

165
182

182
6/6

Bosch Rexroth AG

Industrial Hydraulics

VT SR41 bis VT SR43

RD 30209/07.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

2004 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


Alle Rechte vorbehalten. Kein Teil des Werkes darf in irgendeiner Form
ohne vorherige schriftliche Zustimmung von Bosch Rexroth AG, Industrial
Hydraulics reproduziert oder unter Verwendung elektronischer Systeme
gespeichert, verarbeitet, vervielfltigt oder verbreitet werden. Zuwiderhandlungen verpflichten zu Schadensersatz.
Die angegebenen Daten dienen allein der Produktbeschreibung. Eine
Aussage ber eine bestimmte Beschaffenheit oder eine Eignung fr einen
bestimmten Einsatzzweck kann aus unseren Angaben nicht abgeleitet
werden. Die Angaben entbinden den Verwender nicht von eigenen Beurteilungen und Prfungen. Es ist zu beachten, dass unsere Produkte einem
natrlichen Verschlei- und Alterungsprozess unterliegen.

183

RE 29 993/02.03
Replaces: 06.97

Electrical amplifier for flow control with


servo-valves
Type VT- SR7
H/A/D 5657/97

Series 1X

01
Type VT-SR7-1X/...

Table of contents
Contents
Features
Ordering code
Technical data
Functional description

Block circuit diagram / pin assignment


Preferred types
Engineering / maintenance notes / supplementary information
Unit dimensions

Page
1
1
2
2

3
4
4
4

Features
VT-SR7 amplifiers are used to control axial piston units of type
A4VSHS.
The assembly is fitted with an oscillator/demodulator for inductive
position feedback and a PID-controller for controlling the swivel angle of the pump. The parameters for the controller are matched to
the individual size of the axial piston unit.
The valve current is enabled by means of a relay call-up. The command value can be fed forward via the differential input or the command value input.

A measuring instrument installed in the front panel indicates the


servo-valve current; 100 % corresponds to 60 mA.
Card holder:
Type VT 3002-2X/32, see RE 29 928, single card holder without
power supply unit
Power supply unit:
Type VT-NE31-1X, see RE 29 929 compact power supply unit
115/230 VAC 24 VDC, 7 VA

Ordering code
VT-SR7

1X /

Amplifier for flow control with


servo-valves
Series 10 to19
= 1X
(10 to 19: unchanged technical data and pin assignment)
Without 15 V voltage regulator
With 15 V voltage regulator
1)

=0
=1

For example: with/without PID-controller


For the additional PID-controller, the
technical controller data must be specified.

A4VS40HS =
A4VS71HS =
A4VS125HS =
A4VS180HS =
A4VS250HS =
A4VS355HS =
A4VS500HS =
A4VS750HS =
A4VS1000HS =

Further details in clear text 1)


Axial piston unit size 40
Axial piston unit size 71
Axial piston unit size 125
Axial piston unit size 180
Axial piston unit size 250
Axial piston unit size 355
Axial piston unit size 500
Axial piston unit size 750
Axial piston unit size 1000

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

VT- SR7

1/4

RE 29 993/09.02

184

Technical data (for applications outside these parameters, please consult us!)
Operating voltages:
With voltage regulator
UB
Upper limit value
uO(t)max
Lower limit value
uO(t)min
Without voltage regulator
UO; UM
Upper limit values
uO(t)max; uM(t)max
Lower limit values
uO(t)min; uM(t)min
I
Power consumption (without valve) at UO = 24 V 1)
Inputs:
Command value 1
Ui
Command value 2 (with J9)
Ui
Actual position value
Ui
Enable
Ui
Controller changeover
Ui
Reserve relay
Ui
Outputs:
UM
Regulated output voltage 1)
Valve current
Imax
Valve current command value (with J10)
Uo
Relay call-up voltage
U
f
Dither signal
Relay data:
U
Nominal voltage
Response voltage
U
Release voltage
U
Switching time
t
Coil resistance (at 25 C)
R
Type of connection
Card dimensions
Front panel dimensions:
Height
Width soldering side
Width component side
Permissible ambient temperature range
J
Storage temperature range
J
Weight
m
1) for version with voltage regulator

24 VDC
28 VDC
22 VDC
24 VDC and 15 VDC (stabilised)
28 VDC; 15.2 VDC
22 VDC; 14.8 VDC
< 150 mA
0 to 10 V (Ri= 50 k)
0 to 10 V (Ri= 50 k)
0 to 10 V (Ri= 50 k)
+ 24 V with J13; 0 V with J12 (Ri= 700 ; relay circuit)
+ 24 V with J13; 0 V with J12 (Ri= 700 ; relay circuit)
+ 24 V with J13; 0 V with J12 (Ri= 700 ; relay circuit)
15 V 2 %; 150 mA
60 mA
10 V + 60 mA (measuring output)
+ 24 V (+ UO)
340 Hz (ISS = 3 mA)
+ 26 V
> 13 V
1.3 V to 6.5 V
< 4 ms
700
32-pin male connector, DIN 41 612, form D
Euro-card 100 x 160 mm, DIN 41 494
3 HE (128,4 mm)
1 TE (5.08 mm)
7 TE
0 to + 50 C
20 to + 70 C
0.3 kg

Functional description
VT-SR7 amplifiers operate with a push-pull output stage with bipolar transistors. The output of this output stage can be activated or
deactivated using an enable circuit (relay K2). The enable is indicated by lighting up of LED "H2" on the front panel. The switching
voltage of all relays is set to either 0 V or + UO by means of jumpers
J12 and J13 (factory setting + UO).
The output stage consists of an I-controller with connected dither
signal generator. The amplitude of the dither signal can be adjusted
using R7. The input stage (current command value) is controlled via
a PD-controller. The actual current value fed back is indicated by the
instrument on the front panel.
The oscillator/demodulator is used for acquiring the position. It is
designed as plug-in board, the parameters of which are adapted to
the relevant size of the axial piston unit.
The position command value and actual position value are fed to the
PD-controller, with the D-component acting only on the actual value
(velocity feedback).

RE 29 993/09.02

The zero point can be adjusted from the front panel using R3 ("NP").
The required symmetric operating voltage UO is protected against
reverse polarity. If the printed circuit board is not fitted with a voltage regulator for supplying the controller and displacement transducer electronics, an additional, stabilised auxiliary voltage UM must
be provided. The auxiliary voltage connection is protected against
reverse polarity up to a maximum current of 1 A.
Optionally, the amplifier can be provided with a PID-controller (Dcomponent acts only on the actual value). This controller can be
used to superimpose a further closed control loop (e.g. for drive control). The P- and D-component can be adjusted on the front panel.
The PID-controller configuration is customised and must therefore
be indicated in clear text on the order. When dispatched, a special
type designation is assigned to the amplifiers.

2/4

VT- SR7

VT- VR7

3/4

Operating voltage
22 to 28 VDC

UB

+ UB

Controller output1)
(differential amplifier output)

Command value
Actual value1)
(Reference potential)

Call-up voltage for


relay K2

Position command value 1

Position command value 2 (J)


or
controller output (J10)

J9

J14

R65

R13

+ UB = 24 V

J10

J6

UB

PID

DV F

PD

+ UB

R2

R3

NP

R1
UB

J12

15 V

Controller

+ 15 V

J13

Valve current
"IX / %"

UDSS

R7

Controller

1) The controller input can be converted into a differential input by removing R13 and plugging in J14 and R65.

20c

16c

14c

32c

28c

30c

14a

16a

30a

28a

6 F

K2

K2

M0

22c

18c

12c

32a

16a

18ac

4a

4c

2c

6a

16a

24c

24a

26c

26a

F = On front panel

2 F

H2

+ UB (

15 V ( UM)

M0

+ 15 V (+ UM)

Actual position
value

Enable

B1 (C)

A1 (D)

C1 (B)

D1 (A)

mit J12)

Servo-valve connection:
1 valid for sizes 40 to 355
( ) valid for sizes 500 to 1000

IW9

185

Block circuit diagram / pin assignment

01

RE 29 993/09.02

186

Preferred types

Engineering / maintenance notes /


supplementary information

Material no.

Type

R900035612
R900030717
R900557769
R900029274
R900579280
R900029181

VT-SR7-1X/0/A4VS.355HS
VT-SR7-1X/0/A4VS.500HS
VT-SR7-1X/1/A4VS.180HS
VT-SR7-1X/1/A4VS.250HS
VT-SR7-1X/1/A4VS.355HS
VT-SR7-1X/1/A4VS.500HS

The amplifier may only be plugged or unplugged when disconnected from the power supply!
Command values may only be switched via relays with goldplated contacts (small voltages, small currents)!
For switching card relays (enable, controller changeover, reserve)
use only contacts with a load-carrying capacity of ca. 40 V/ 50 mA.
Always shield command value and actual value cables; leave one
end of shield open and connect the card-sided end to the ground
()!
Do not lay signal cables near power cables!
Recommendation: 1. Also shield solenoid cables (one end to )!
2. For lengths up to 50 m use cable type LiYCY
1.5 mm2 , for greater lengths, please consult us!
Caution: When pilot pressure is applied to the actuating
equipment and relay K2 is deactivated or the voltage supply is
disconnected, the pump may swivel to its maximum position!
Note: Electrical signals brought out via control electronics (e.g. actual
value) must not be used for switching safety-relevant machine functions! (See also the European standard Safety requirements for fluid
power systems and components - Hydraulics", prEN 982.)

Unit dimensions (dimensions in mm)

P
D

89

H3

100

H2

IX / %

3HE (128,4)

H1

NP
DV
1
3
5

2
4
6

VT-SRXX
2

8TE (40,3)
7

165
182

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
eMail: info@boschrexroth.co.uk

RE 29 993/02.03

4/4

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application
can be derived from our information.
The details stated do not release you from the
responsibility for carrying out your own
assessment and verification. It must be
remembered that our products are subject to a
natural process of wear and ageing.

VT- SR7

187

RE 30214/06.05
Replaces: 08.04

Analogue amplifier module

1/8

Type VT-MRMA1-1

Component series 1X

H7125

Table of contents
Contents

Features
Page

Features

Ordering code

Functional description

2, 3

Suitable for controlling a DC motor actuated pressure reducing valve with electrical position feedback, type (Z)DRS, size 6,
component series 1X.
Innovative modular snap in housing with detachable plug-in
screw connectors

Block circuit diagram, pin assignment

Configurable pressure command value input

Technical data

Separately adjustable ramp times (up and down)

Terminal assignment

Linearisation

Unit dimensions

Electronic limit stops for the actuator drive

Engineering / maintenance notes / supplementary information 7


Setting recommendation

7, 8

Position controller with recognition of position command


value reached
Enable input
Output ready for operation
Output position command value reached

Suitable power supply unit:


Type VT-NE30-2X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 108 W

Configurable actual pressure value input


Integrated pressure switch function with adjustable switching
thresholds
Measuring sockets that can be changed over

Suitable pressure transducer:

Fault detection (cable breaks, short-circuits, etc.)

Type HM17-1X/..., see RE 30269

LED lamps: Ready for operation


(green)
Enable
(yellow)
Fault detection for act. pressure value input (red)

Pressure measuring range according to the selected pressure


stage

188
2/8

Bosch Rexroth AG

Hydraulics

VT-MRMA1-1

RE 30214/06.05

Ordering code
VT - MRMA1 1

1X V0

*
Further details in clear text

Analogue amplifier of innovative modular design


for controlling DC motor actuated (Z)DRS 6 pressure
reducing vavles (component series 1X)

Basic version
=1

Component series 10 to 19
(10 to 19: unchanged technical data and pin assignment)

Basic version
= 1X

Functional description
General

Pressure command value attenuator Gw [4]

The amplifier module is to be snapped onto top hat rails according to EN 60715. It is electrically connected via 4 plug-in screw
connectors with 4 connections each. The module is operated
with 24 V DC voltage.
Power supply unit [1]

Potentiometer Gw acts as attenuator [4] and determines the


internal maximum pressure command value. The adjustment
range is 0% to 130%.

An internal power supply unit provides all of the internally


required positive and negative supply voltages.
Pressure command value feedforward [2]
The internal pressure command value signal is generated from
an external pressure command value signal applied to input [2]
and the zero point offset [2] (zero point potentiometer Zw on the
front panel). An increasing/decreasing pressure command value
results in an increase/reduction in pressure. With the help of DIL
switches S1.1 to S1.6 (see commissioning instructions) the differential input can be configured as 4 to 20 mA current input.
Standard
value

Current
input

Differential input

Pressure command value


at measuring socket v
(position 0)

0%

4 mA

0V

0V

100%

20 mA

10 V

10 V

A break of a pressure command value cable is detected (output ready for operation) and results in the deactivation of the
output stage!
Ramp generator [3]
The ramp generator [3] generates a ramp-shaped output signal
from a given step signal. Here, the ramp time refers to a change
in the pressure command value of the input signal by 100%.
The ramp time is not extended or shortened by the downstream
pressure command value attenuator [4].
The ramp times for pressure increase and pressure reduction
can be adjusted separately by means of potentiometers t <
and t > on the front panel of the module. The current ramp time
values can be checked and preset with the help of the measuring socket v that can be changed over (also on the front panel).
Note on the adjustment of the ramp time:
Value at measuring
socket (position 4
10 5
or 5)
Ut in V

t =

1 Vs
Ut

Linearisation [5] is used for compensating for the non-linear


valve characteristic curve. The required valve position command
value is generated from the pressure command value.
Amplitude limiter [6]
The amplitude limiter [6] limits the internal valve position command value to + 110% and 5%.
Actual valve position value acquisition [12]
A voltage output is used for supplying the position transducer.
The actual valve position value fed back by the position transducer can be corrected with the help of zero point potentiometer Zx and sensitivity potentiometer Gx. The internal actual
position value signal thus generated is made available to the
valve position controller [7] for further processing. Breaks of the
position transducer cables are recognized by the fault detection
feature [8].
Electronic limit stop
The electronic limit stops are a functional part of the actual valve
position acquisition feature [12].
The adjustment stroke of the valve is mechanically limited. The
effective working range is within these mechanical limit stops.
To prevent an unwanted movement to the mechanical limit stops
(e.g. during set-up), so-called electronic limit stops are provided within a closer range for safety reasons. These limit stops
cannot be passed, since the output stage is deactivated accordingly. The electronic limit stops are only effective if the sensor
and motor are correctly wired!

0%

100%
Working range
of the valve

Electronic limit stop


Mechanical limit stop
3

2 1 0.5 0.1 0.05 0.03 0.02 0.01

Valve position controller [7]

Current ramp time


0.1 0.2 0.33 0.5 1 2 10 20 33.3 50 100
t in s ( 20 %)
The following is valid:

Linearisation of the valve characteristic curve [5]

Measurement example:

Measurement: Ut = 5 V => t =

1 Vs
5V

The valve position controller [7] generates the control output


for the clocked output stage from the position deviation of the
system. The position controller is optimised to a specific valve
type.
Output stage [10]

= 0.2 s

The output stage [10] generates the clocked control voltage for
the DC motor that acts as actuator in the pressure reducing

189
Hydraulics Bosch Rexroth AG

RE 30214/06.05 VT-MRMA1-1

3/8

Functional description (continuation)


valve. The output stage output is short-circuit-proof. The output
stage is de-energized in the event of an internal error signal [8]
or missing enable [11].
Recognition of position command value reached [9]
A position command value reached output is provided as auxiliary
process variable. This output is connected to the 24 V operating
voltage as soon as the system deviation resulting from the valve position command value and the controlled actual valve position value
is 5% of the nominal stroke and the internal ramp output signal
corresponds to the applied pressure command value.
Fault detection [8]
The following is monitored:
Cable break of the pressure command value cables
Exchange of pressure command value cables
Cable break of the position transducer cables
Short-circuit of position transducer supply with L0 (0 V)
Due to the integrated protective motor circuit, the following can
be detected:
Exchanged motor cables (positive feedback)
Jamming of the valve actuator drive
Motor cable break
If no error is present, the green LED ready for operation
lights up on the front panel and the output ready for operation is connected to the 24 V operating voltage.
Protective motor switch
The protective motor circuit is a functional part of fault detection
[8]. To ensure proper operation of the valve actuator drive, the
required adjustment time is monitored during each pressure adjustment process. When an internally determined, max. permitted adjustment time (approx. 4 s) is exceeded, the output stage
is deactivated in order to prevent damage to the motor caused
by continuous application of load current.
The output ready for operation is connected to 0 V and the
green LED on the front panel goes out. When the cause of fault
is eliminated, the electronics can be re-activated by resetting
and subsequent setting of the enable.
The protective motor circuit detects:
Exchanged motor cables (positive feedback)
Motor cable break
Jamming of the valve actuator drive
Enable function [11]
The enable function [11] activates both, the position controller
and the output stage via the external control. The enable signal is
indicated by a yellow LED
on the front panel of the module.

configured either as 0 to 10 V voltage input or as 4 to 20 mA


current input.
Caution! If this input is configured as 4 to 20 mA input
and the actual pressure value input is connected in series with
another separate, external current input, the module electronics outputs an offset current at terminal 1. This must be taken
into account when the external current input is matched!
The actual pressure value input is monitored for the following
points (depending on the characteristics of the pressure transducer electronics):
Break of actual pressure value cables
Exchanged actual pressure value cables
Break of the pressure transducer operating voltage cable
Break of the pressure transducer ground cable
When one of these faults is detected at the actual pressure
value input, both pressure switch signals, A and B, are connected to 0 V and the red LED (!) on the front panel of the
amplifier module lights up.
Pressure switch function [14]
The integrated pressure switch [14] compares the internal actual
pressure value with a window around the pressure command
value that can be individually adjusted (DIL switches S2.1 to
S2.9). Depending on whether the actual pressure value falls below the lower or exceeds the upper limit, the relevant pressure
switch signal A or B drops to 0 V. When the actual pressure value is within the pressure command value window, both pressure
switch signals are connected to the 24 V operating voltage.
Exception: In the event of a cable break of one of the two actual
pressure value cables, both signals A and B drop to 0 V.
(For the setting of the pressure switch thresholds by means of
DIL switch S2, see commissioning instructions).
Change-over of measuring points [15]
With the help of measuring sockets v and on the front panel,
various internal measuring points (v0 to v5) can be checked. The
measuring points can be selected by means of measuring point
selector switch [15] at the front of the housing.
Measuring point
Press. comm. value wP

Switch
Measured signal v (ref. is )
position
0
0% 0 V and 100% 10 V

Act. press. value xP

0% 0 V and 100% 10 V

Valve comm. value

wS

0% 0 V and 100% 10 V

Act. valve value

xS

0% 0 V and 100% 10 V

Ramp time up

t<

10 mV to 10 V

Internal controller and output stage enable

Ramp time down t >

10 mV to 10 V

The controller and the output stage are enabled, when the external enable [11] is set and the electronics is ready for operation,
i.e. the fault detector [8] does not detect an error.

No function

0V

No function

< 10 V

Actual pressure value input [13]

No function

< 10 V

The internal actual pressure value signal is generated from the


signal applied to the actual pressure value input [13] and the
zero point offset (zero point potentiometer Zp on the front panel). Sensitivity potentiometer Gp can be used to compensate
for deviations of the pressure transducer caused by tolerances.
By means of DIL switches S1.7 and S1.8 (see commissioning
instructions) and proper matching by means of zero point potentiometer Zp and sensitivity potentiometer Gp, the input can be

No function

< 10 V

Note:
Switch positions 6 to 9 have no function. They are merely used
for determining the switch position in case that the arrow marking on the measuring point selector switch is no longer legible
due to damage.
[ ] = Cross-reference to block circuit diagram on page 4

01

190
4/8

Bosch Rexroth AG

Hydraulics

RE 30214/06.05

VT-MRMA1-1

Block circuit diagram / pin assignment

t< 3 t>

S1.1-1.6
wP

+ wP

wS

wP

U/I
U
Zw

t<

5, 6

16

PI

U
U

EN
U

11
S1.71.8

+ xP

U/I
U

GP

13
ZP

L0 (0V)

12

DC

+ 7.5 V
M0

11

DC

7.5 V

L0

1 Power supply unit

1
+ sensor

3
sensor

13
wP
xP
wS
xS
t<
t>

0
1
2
3
4
5

78

14

A
B
signal v

15

L0

9 Recognition of position value reached

2 Pressure command value feedforward

10 Output stage

3 Ramp generator

11 Enable function

4 Pressure command value attenuator

12 Actual valve position value acquisition

5 Linearisation of valve characteristic curve

13 Actual pressure value input

6 Amplitude limiter

14 Pressure switch function

7 Valve position controller

15 Measuring point selection

8 Fault detection

901

Operating
voltage

4
5

L0

14

xP

+M
15

xS

Zx

S2.12.9

456

xP

12
U

Gx

xS

10

EN

23

Enable

xS = wS

t>

Ready for
operation

Gw

10

0V

191
Hydraulics Bosch Rexroth AG

RE 30214/06.05 VT-MRMA1-1

5/8

Technical data (for applications outside these parameters, please consult us!)
Operating voltage
Operating range

UO 24 VDC + 40 % 20 %
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 21 V

Power consumption

PS < 50 VA
< 3.5 A

Current consumption i(t)max (motor switched on)


Imax (during actuating process)

<1A

Imin (when output stage is switched off)

< 120 mA

Fuse

1.6 A, self-healing (thermal overload protection)

Inputs:
Analogue
Pressure comm. value

(differential input)

Ui 0 to +10 V; Ri > 100 k

Pressure comm. value

(current input)

Ie 4 to 20 mA; load Rl = 100

Actual pressure value

(differential input)

Actual pressure value

(current input)

Ue 0.5 to +5 V; Ri > 100 k


Ie 4 to 20 mA; load Rl = 100

Digital
Enable

ON

U +8.5 V to UO; Ri > 100 k

OFF

U 0 to +6.5 V; Ri > 100 k

Adjustment ranges
Pressure command value zero point

(potentiometer Zw) 30 %

Pressure command value attenuator

(potentiometer Gw) 0 to 130 %1)

Actual pressure value sensitivity

(potentiometer Zp) 5 %

Actual pressure value gain

(potentiometer Gp) 90 to 120 %1)

Actual valve position value sensitivity

(potentiometer Zx) 15 %

Actual valve position value gain

(potentiometer Gx) 90 to 120 %1)

Ramp times

(potentiometers t < and t >)

0.1 to 100 s

Outputs
Output stage

Ueff 0 Veff to UO,eff

Sensor supply voltage

U 0 V and +10 V 3 %

Mesuring socket

U 0 V to +10 V 2 %; Imax = 2 mA

Ready for operation

ready for operation

U > 16 V

(Ri = 10 k; 50 mA)

not ready for operation

U <1V

(Ri = 10 k; 50 mA)

reached

U > 16 V

(Ri = 10 k; 50 mA)

not reached

U <1V

(Ri = 10 k; 50 mA)

Actual pressure value > lower pressure switch threshold

U > 16 V

(Ri = 10 k; 50 mA)

Actual pressure value < lower pressure switch threshold

U <1V

(Ri = 10 k; 50 mA)

U > 16 V

(Ri = 10 k; 50 mA)

Position command value


reached
Pressure switch signal A

Pressure switch signal B


Actual pressure value < upper pressure switch threshold

Actual pressure value > upper pressure switch threshold U < 1 V

(Ri = 10 k; 50 mA)

Type of connection

4 plug-in screw connectors with 4 connections each

Type of mounting

top hat rail TH 35-7.5 to EN 60715

Type of protection

IP 20 to EN 60 529

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 C to +70 C

Weight
Always with correctly set zero point

m 0.15 kg

1)

01

192
6/8

Bosch Rexroth AG

Hydraulics

VT-MRMA1-1

RE 30214/06.05

Terminal assignment
xp

+ xp

10

sensor
valve plug contact 3

11

Actual pressure value


input

Position transducer
supply

Position command value


reached
Ready for operation

0V
Operating voltage

+ sensor
valve plug contact 1

12

+ UB

wP

13

+ wP

14

enable

15

M
valve plug contact 5

Pressure command value


input

Pressure switch signals

Enable
Actual position value
input

xs = ws

xs
valve plug contact 2

16

+M
valve plug contact 4

Valve motor connection

Unit dimensions (in mm)


113,6

13 14 15 16

top hat rail TH 35-7.5

9 10 11 12

Gx

Zw

Zx

! Gp

t<
t>

Zp
7 8

2 3

5 6

9 0 1

v0
I
v5

99,0

Gw

to EN 60715

5 6 7 8
1 2 3 4

22,5
Potentiometers

115,0
LED lamps

Gw

Pressure command value attenuator

Ready for operation

(green)

Zw

Pressure command value zero point

Enable

(yellow)

Gp

Actual pressure value gain

Zp

Actual pressure value zero point

Gx

Actual valve position value gain

Zx

Actual valve position value zero point

t<

Ramp time up

Load zero

t>

Ramp time down

Pressure cell cable break

Measuring sockets
Measuring signal

(red)

193
RE 30214/06.05 VT-MRMA1-1

Hydraulics Bosch Rexroth AG

7/8

Engineering / maintenance notes / supplementary information


Before installing and commissioning the unit, make sure that the DIL switches on the printed circuit board of the amplifier module are correctly set (for the function of the DIL switches, see commissioning instructions).
The DIL switches on the printed circuit board of the amplifier may only be set when the unit is disconnected from the power
supply!
The amplifier module may only be wired or connected and opened when disconnected from the power supply!
The distance to aerial lines, radio sources and radar equipment must be at least 1m!
Do not lay motor and signal cables near power cables!
The valve is to be connected using a 5-wire cable. For cables up to 50 m length use cable type LiYCY 0.5 mm2. In the case of
greater lengths, please consult us.
If the valve cable requires shielding, connect the shield to protective ground (PE) on the module side. In some cases (for example in the case of strong interference on PE), it may be useful to connect the shield directly to L0 of the amplifier module and
leave the other end open (risk of earth loops!).
When using a differential input, both inputs must always be activated or deactivated simultaneously.
Electrical signals (e.g. signal ready for operation) brought out via control electronics must not be used for switching safety-relevant machine functions! (See also European standard Safety requirements for fluid power systems and components - hydraulics, DIN EN 982)
Do not cut cable ends too short in order to allow opening of the module also when it is wired (e.g. for setting the DIL switches).
Make sure that the ground of the pressure command value (wP, terminal 5) has the same potential ( equipotential bonding
bar) as the ground (L0, terminal 11) of the power supply unit. This suppresses interference more effectively.
For details regarding environmental testing in the field of EMC (electromagnetic compatibility), climate and mechanical stress,
see RE 30214-U (declaration on environmental compatibility ).
For adjusting the potentiometers and the measuring point selector switch use a screw driver with a blade width of 4 mm.

Setting recommendation
Factory settings
When delivered, the electronics is characterised by the following features:
Minimum ramp times.
Attenuator Gw set to 100%.
The linearity of the complete system (module electronics and valve) are subject to manufacturing tolerances.
Fine-tuning of the complete system
Preconditions:
The system-specific connections must be made!
The DIL switches on the printed circuit board must be set according to the individual requirements!
The hydraulic system must be switched on.
Make sure that the hydraulic oil has reached the (controlled) operating temperature for fine tuning!
Signal

Setting

Set the external pressure command value feedforward to 0 %.


Pressure command value zero Set measuring point selector switch to 0 .
point
Use zero point potentiometer Zw to match the measuring signal at v: 0 V 5 mV ( = 0%)

Maximum pressure command


value

Note: Before the maximum value is matched, the zero point must have been matched according
to step 1!
External pressure command value feedforward = 100 %
Set measuring point selector switch to 0.
Use zero point potentiometer Gw to match the measuring signal at v: 10 V 5 mV ( = 100 %)
Select the potentiometer to be adjusted by means of the measuring point selector switch:

Ramp times

Position 4 for ramp up t < and position 5 for ramp down t >.
Adjust the ramp time according to formula or table (see functional description ramp generator and
check the setting at measuring socket v.

01

194
8/8

Bosch Rexroth AG

Hydraulics

VT-MRMA1-1

RE 30214/06.05

Setting recommendation (continuation)


Signal

Setting
Note: Before the 20% actual pressure value is calibrated, the pressure command value must
have been matched according to steps 1 and 2!
Connect the valve electrically.
Measure the sensor supply voltage on the module side between terminals 4 and 3: +10.0 V 300 mV
Set the external pressure command value feedforward to 20%.
Apply enable signal externally.

20% actual
pressure value

Setting of the actual pressure value signal (= voltage between terminals 2 and 1) to 20 % of the
nominal pressure value using Zx :
Actual pressure value signal in dependence upon the pressure transducer used:
Pressure transducer
used

Output signal (20 %)

Voltage between
terminals 2 and 1

0.5 5 V output

+1.40 V

+1.40 V

4 20 mA output

+7.2 mA

+0.72 V (Rload = 100 )

Set measuring point selector switch to 1 .


Use potentiometer Zp to match the measuring signal at v: +2.00 V 5 mV
Note: Before the maximum value is matched, the calibration of the 20% actual pressure value
according to step 4 must have been completed!
Set the external pressure command value feedforward to 100% .
Apply enable signal externally.

Maximum actual
pressure value

Setting of the actual pressure value signal (= voltage between terminals 2 and 1) to 100 % of the
nominal pressure value using Gx :
Actual pressure value signal in dependence upon the pressure transducer used:
Pressure transducer
used

Output signal (20 %)

Voltage between
terminals 2 and 1

0.5 5 V output

+5.00 V

+5.00 V

4 20 mA output

+20 mA

+2.00 V (Rload = 100 )

Set measuring point selector switch to 1.


Use potentiometer Gp to match the measuring signal at v: +10.00 V 5 mV
6

Actual pressure
value

Individual adjustment of the


maximum pressure command
value

Check the two working points (steps 4 and 5).


If required, repeat steps 4 and 5.
Adjust external pressure command value according to your individual needs.
Example: Reduction of 100 % external pressure command value to 80 %
Set external pressure command value feedforward to 100 %
Turn measuring point selector switch to 0
Use potentionmeter Gw to adjust the measured signal at measuring socket v according to the
individual requirements: Setting in this example: 8.0 V 5 mV (= 80 %)

Bosch Rexroth AG
Hydraulics
Zum Eisengiesser 1
97816 Lohr am Main, Germany
Telephone +49 (0) 93 52 / 18-0
Fax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The given information does not
release the user from the obligation of own judgement and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

195

RE 30221/09.05
replaced: 05.05

Analogue amplifier module

1/8

Type VT-MRPA1-...

Series 1X

Overview of contents
Contents

Features
Page

Suitable for controlling direct operated proportional relief


valves with electrical position feedback (type DBETR-1X)
or for proportional flow control valves with electrical position
feedback (type 2FRE...)

Features

Ordering details

Functional description

Block circuit diagram / connection allocation

Technical Data

Ramp generator with separately adjustable ramp times


up/down

Terminal allocation

Zero point potentiometer

Unit dimensions

Amplitude attenuation

Engineering notes / maintenance guidelines /


additional information

Setting recommendations

Command value input 10 V (differential input)

Enable input
Polarity protection for the power supply
Power supply with a DC/DC convertor without a raised zero
point

Suitable power supply:

Cable break recognition in the position transducer branch

Type VT-NE30-1X, see RE 29929


Compact power supply 115/230 VAC 24 VDC, 70 VA

LED indicators:

Operational (green)
Enable (yellow)

Measurement sockets for:

Command value w
Actual valve x
Ramp times t<, t>

Attention:
When replacing a VT 11025, VT 11033 and VT 11034 the
changed position transducer connections have to be taken
into account!

196
2/8

Bosch Rexroth AG

Hydraulics

VT-MRPA1-...

RE 30221/09.05

Ordering details
VT-MRPA1

1X V0

Analogue amplifier of modular design

Further details in clear text

For controlling a DBETR-1X valve


For controlling a 2FRE6-1X valve
For controlling a 2FRE10 and 16-1X valve

Basic version

= 100
= 150
= 151

Basic version

Series 10 to 19
= 1X
(10 to 19: unchanged technical data and connection allocation)

Functional description
General

Amplitude attenuation [5]

These amplifier modules can be snapped onto carrier rails to


EN 60715. The electrical connections are made by means of
screw terminals. The modules are operated using 24 VDC.

The amplitude attenuator Gw can be used to adjust the


maximum value, within the range of 0 - 100 %, to the hydraulic
requirements.

Power supply unit [1]

Amplitude limiter [6]

The amplifier modules comprise of a power supply unit with an


inrush current limiter. It provides all the internally required positive and negative supply voltages. The inrush current limiter
prevents high inrush current peaks.

The internal command value is limited to 0 % and 110 %.

Command value preselection

Oscillator [9]
The oscillator generates the control signal for the inductive
position transducer.

The internal command value signal is generated from the sum


[3] of the external command value signal applied to
differential input [2] and the zero point offset (zero point potentiometer Zw).

Demodulator [10]

A positive command value results in a current increase in the


solenoid and, thereby an increase in pressure at the valve.

Controller for the valve spool position [7]

Enable function [11]


The enable function is used to enable the current output stages
and to pass the internal command value signal on to the ramp
generator. A LED on the front panel indicates the enable signal. When the enable is activated, the internal command value
(an applied optional command value) changes according to the
set ramp time. As a result of this, valve does not open suddenly
when activated.
Ramp generator [4]

The demodulator uses the position transducer signal to


provide the actual value signal of the valve spool position:
+100 % = +10 V at measurement socket x.

The position controller is used to minimise the valve hysteresis


and is optimised to meet the individual valves requirements.
Current output stages [8]
The current output stage generates the clocked solenoid current for the proportional valve. The solenoid current is limited to
approx.
1.85 A. The output stage outputs are short-circuit-proof. The
output stages are de-energised in the case of an internal fault
signal or missing enable.
Fault detection [14]

The ramp generator limits the gradient of the control variable.


Due to the amplitude attenuator, the ramp time is not lenghtened or shortened.

The position transducer cable is monitored for cable break and


short circuits and the output stage for overcurrent.

Notes on the adjustment and measurement of the ramp time:


[ ] = Cross-reference to the block circuit diagram on page 3
Value at measuring socket t < or t > Ut in V

Actual ramp time (20 %)

20

33

50

Ut in V
t in ms

0,5

0,3

0,2

0,1

0,05

0,03

0,02

100 200 333 500 1000 2000 3333 5000

The following is valid:


Example:

t in ms

Measured
Results in

t=

100 Vms
Ut

Ut = 5 V
100 Vms
t =
5V

= 20 ms

Operating
voltage

DC

DC

11

Zw

Zero point actual value

Ramp time up

Ramp time down

Amplitude attenuator

t>

Gw

Zero point com. value

L0

Zx

Zw

0V

+ UB

UB

&

Gx

t>

Operational
Enable

=
=

Command value
Actual value

Gw

PID

M0

M0

Gx

Zx

10

UB

12

11

10

Enable function
Proportional valve
Inductive position transducer

11
12
13
14

Ramp generator
Amplitude attenuator
Amplitude limiter
Controller for valve spool position

5
6
7

Hydraulics Bosch Rexroth AG

Fault detection

Oscillator
Demodulator

9
10

Differential amplifier
3

Command value summator

13

Current output stage

Power supply unit

12

Solenoid

When replacing a VT 11025, VT 11033 and VT 11034 the


changed position transducer terminal connections has to be
taken into account. Pins 6 and 12 are exchanged.

Attention:

Gmax

Actual value sensitivity

t>

t<

+ 15 V
+ 10 V
M0
10 V
15 V

14

t<

VT-MRPA1-...

t<

Enable

Ref. potential IN

Com. value: 10 V + IN

Differential input (Usoll):

RE 30221/09.05

197
3/8

Block circuit diagram / connection allocation

01

198
4/8

Bosch Rexroth AG

Hydraulics

VT-MRPA1-...

RE 30221/09.05

Technical Data (for applications outside these parameters, please consult us!)
Operating voltage

UB 24 VDC +40 % 20 %

Operating range:
Upper limit value

uB(t)max 35 V

Lower limit value

uB(t)min 18 V

Power consumption

PS < 24 VA

Current consumption

I <2A

Fuse

Thermal overload protection


(with reclosing feature when the temperture falls below the threshold)

Inputs:
Analogue
Command value (differential input IN)

Ue 0 to +10 V; Re > 50 k (current input on enquiry)

Digital
Enable

ON

U 8.5 V to UB; Re > 100 k

OFF

U 0 to 6.5 V; Re > 100 k

Adjustment ranges:
Command value zero point (potentiometer Zw)

30 %

Actual value zero point (potentiometer Zx)

10 %

Ramp times (potentiometer t < and t >)

20 ms to 5 s

Amplitude attenuator (potentiometer Gw)

0 % to 110 % (valid for setting the zero point = 0 %)

Outputs:
Current output stages
Oscillator

I 0 to 1.85 A; short-circuit-proof; clocked to approx. 5 kHz


USS 2 V; 10 mA per output
f 5.6 kHz 10 %

Measuring sockets
Ramp time t <

U 20 mV to 5 V

Ramp time t >

U 20 mV to 5 V

Actual value x

U 0 to 10 V

Command value w

U 0 to 10 V

Connection type

12 threaded terminals

Mounting style

Carrier rails TH 35-7.5 to EN 60715

Protection type

IP 20 to EN 60529

Dimensions (W x H x D)

40 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 C to +70 C

Weight

m 0.14 kg

Note!
For details regarding the environmental simulation test
covering EMC (electro-magnetic compatibility), climate and
mechanical loading see RE 30221-U (declaration regarding
environmental compatibility).

199
RE 30221/09.05

Hydraulics Bosch Rexroth AG

VT-MRPA1-...

5/8

Terminal allocation
Connection cable (recommendation):
operating
voltage

Enable

Differential
input
Position
transducer, primary

+UB

0V

UF

IN

10

+IN

11

7
Solenoid

2-core cable, single screen,


cross-section 1.5 mm2

Free

12

4
Position
transducer
control

3-core cable, single screen,


max. cross-section 1.5 mm2

01

Attention: The position transducer connection


has changed when compared to the VT 11025,
VT 11033 and VT 11034!

Unit dimensions (dimensions in mm)


Carrier rails TH 35-7,5

LED-indicators:

to EN 60715

Operational (green)
Enable (yellow)

7 8 9 10 11 12

Potentiometer:
REXROTH

79

VT-MRPA1-100

Gw
Zw
Gx
Zx
t<
t>
t< t>
x w

1 2 3 4 5 6
85,5

40

Gw

Amplitude attenuator for positive com. values

Gx

Position transducer sensitivity (pre-set)

Zw

Command value zero point

Zx

Actual value zero point

t<

Ramp time for increasing command values

t>

Ramp time for decreasing command values

Measuring sockets:
t<

Ramp time up

t>

Ramp time down

Actual value

Command value

Measuring zero

200
6/8

Bosch Rexroth AG

Hydraulics

VT-MRPA1-...

RE 30221/09.05

Engineering notes / maintenance guidelines / additional information


The amplifier module may only be wired when disconnected from the power supply!
Do not lay cables in the vicinity of power cables!
Do not use free-wheeling diodes in solenoid cables!
The distance to antenna cables, radio devices and radar systems must be at least 1 meter!
Always shield command value and position transducer cables; connect the shield to protective earth (PE) on the module side!
In individual cases (e.g. PE subject to strong interference), it may be required to connect the shield of the position transducer
cable directly to the LO of the amplifier module; leave the other end open (risk of earth loops).
Recommendation:

Also shield solenoid cables!


For solenoid cables up to 50 m long, use cable type LiYCY 1.5 mm2!
In case of longer lengths, please consult us!

Do not connect terminal of the position transducer to PE


Use relays with gold-plated contacts for passing on command values (small voltages, small currents)!
Use only instruments Ri > 100 k for taking measurements on the module.
In the case of strongly fluctuating operating voltages, it may be required in individual cases
to use an external smoothing capacitor with a capacitance of at lease 2200 F.
Recommendation: Capacitor module VT 11073 (see RE 29750); sufficient for up to 3 amplifier modules
Attention: When replacing a VT 11025, VT 11033, VT 11034 the changed position transducer connections have to be taken
into account. Pins 6 and 12 are exchanged.

201
RE 30221/09.05

VT-MRPA1-...

Hydraulics Bosch Rexroth AG

7/8

Setting recommendations
The system-specific circuits must be carried out.
Signal

Setting MRPA1

Com. value zero point

Apply the enable signal


Set the externally applied command value to zero
Set the internal command value to zero using
the zero point potentiometer Zw and check via
measurement socket w

Act. value zero point

Set enable signal to OFF or disconnect the


solenoid plug (the valve moves to its mechanical
end stop)
When making any adjustments, pay attention
to the polarity of measuring instrument
measuring sockets!

Ramp times

Adjust the ramp time according to the formula


or table (see functional description of the ramp
generator) and check this at measuring sockets
t > and t <

Maximum values
(amplitude
attenuator Gw)

Note:
Before the maximum values can be matched the zero
point must be correctly set
Command value = apply 100 %.
Using potentiometer Gw set the maximum
adjustment variable and check at the measurement
socket w

01

202
8/8

Bosch Rexroth AG

Hydraulics

VT-MRPA1-...

RE 30221/09.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. Without their
consent it may not be reproduced or given to third parties.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The given information does not
release the user from the obligation of own judgement and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

203

Analogue amplifier modules


for 4/3 and 4/2 proportional
directional valves 4WRE

RE 30219/06.05
Replaces: 12.04

1/10

Types VT-MRPA2 and VT-MRPA1

Component series 1X

H6771

Table of contents
Contents

Features
Page

Features

Ordering code

Functional description

Block circuit diagram / pin assignment VT-MRPA2

Block circuit diagram / pin assignment VT-MRPA1

Technical data

Terminal assignment

Unit dimensions

Suitable for controlling direct operated 4/3 and 4/2 proportional directional valves with electrical position feedback, type
4WRE, sizes 6 and 10, component series 2X
Command value input 10 V (VT-MRPA2), 0 to 10 V
(VT-MRPA1)
Ramp generator with separately adjustable up/down ramp
times
Characteristic curve correction with symmetrically (with
VT-MRPA2 only) adjustable step-change heights and separately (with VT-MRPA2 only) adjustable maximum values

Engineering / maintenance notes / supplementary information 8

Enable input

Adjustment recommendations

Reverse polarity protection of power supply

Power supply unit with DC/DC converter without raised zero


point
Cable break detection in the position transducer branch
LED indicator lamps:
Readiness for operation (green)
Enable (yellow)

204
2/10

Bosch Rexroth AG

Hydraulics

VT-MRPA2, VT-MRPA1

RE 30219/06.05

Ordering code

VT-MRPA

1X V0

Analogue amplifier of modular design


For 4/2 proportional directional valves 4WRE
(with one solenoid)
For 4/3 proportional directional valves 4WRE
(with two solenoids)

Further details in clear text


V0 =
=1
=2

For controlling valve 4WRE 6 (component series 2X)


For controlling valve 4WRE 10 (component series 2X)
Component series 10 to 19
(10 to 19: unchanged technical data and pin assignment)

Suitable power supply unit:


Type VT-NE30-2X, see RE 29929
compact power supply unit 115/230 VAC > 24 VDC,
108 VA

=1
=2
= 1X

Basic version

205
RE 30219/06.05

Hydraulics Bosch Rexroth AG

VT-MRPA2, VT-MRPA1

3/10

Functional description
General

Characteristic curve generator [5]

The amplifier modules are to be snapped onto top hat rails


according to EN 60715. The electrical connection is made
by means of screw terminals. The modules are operated at
24V DC.

The adjustable characteristic curve generator can be used to


adjust step-change heights symmetrically (with VT-MRPA2
only) and maximum values for positive and negative signals
separately (with VT-MRPA2 only) to suit the hydraulic requirements. The actual line of the characteristic curve through the
zero point is not stepped, but linear.

Power supply unit [1]


The amplifier modules are provided with a power supply unit
with switch-on current limiter. The power supply unit provides
all internally required positive and negative supply voltages.
The switch-on current limiter prevents high switch-on current
peaks.

Amplitude limiter [6]

Command value feedforward

The oscillator generates the control signal for the inductive position transducer.

The internal command value signal is generated from the sum


[3] of the external command value signal applied to differential input [2] and the zero point offset (zero point potentiometer Zw).
The following is valid for VT-MRPA2:
A positive command value causes an increase in current in solenoid b and hence a flow in the valve from P to A and from
B to T.
A negative command value causes an increase in current in solenoid a and hence a flow in the valve from P to B and from
A to T.
The following is valid for VT-MRPA1:
A positive command value causes an increase in current in the
solenoid.
Enable function [11]
The enable function is used to enable the current output stages
and to pass the internal command value signal on to the ramp
generator. The enable signal is indicated by an LED on the
front panel. When the enable is granted, the internal command
value changes over the set ramp time (with any command value
selection). The valve does therefore not open suddenly when
activated.
Ramp generator [4]
The ramp generator limits the gradient of the control output.
The downstream step functions and amplitude attenuators do
not shorten or extend the ramp time.
Note on the adjustment and measurement of the ramp time:
Value at measuring socket "t <" or "t >" Ut in V

Current ramp time ( 20 %)

20 33 50

t in ms

Ut in V

0.5

0.3

0.2

t in ms

100

200

333

500 1000 2000 3333 5000

The following is valid:


Example:

Measured
results in

t=

0.1

0.05 0.03 0.02

100 V ms
Ut
Ut = 5 V
t=

100 V ms
5V

= 20 ms

The internal command value is limited to approx. 110 % (with


VT-MRPA2) or +110 % (with VT-MRPA1) of the nominal range.
Oscillator [9]

Demodulator [10]
The demodulator generates the actual value signal of the valve
spool position from the position transducer signal:
100 % 10 V (with VT-MRPA2) or
+100 % +10 V (with VT-MRPA1), respectively
Controller for valve spool position [7]
The position controller is optimised specifically to the valve.
Current output stage [8]
The current output stage generates the clocked solenoid current for the proportional valve. The solenoid current is limited to
2.4 A to 2.6 A per output. The output stage outputs are shortcircuit-proof. In the event of an internal fault signal or missing
enable, the output stages are de-energised.
Fault detection [14]
The position transducer cable is monitored for cable break and
primary-sided short-circuit, and the output stage for overcurrent.
[]=

Cross-reference to block circuit diagrams on


pages 4 and 5

01

Operating
voltage

u
t>

= Readiness for operation


= Enable

w
x
wR

= Actual value zero point

= Ramp time up

= Ramp time down

= Step-change height

= Amplitude attenuator

t<

t>

Sw

Gw

= Command value after ramp

Gx

Zx

8
i

10

UB

Solenoid
b

12

11

10

1
4

Solenoid
a
9

12 Proportional valve
13 Inductive position transducer

5 Characteristic curve generator


6 Amplitude limiter

14 Fault detection

11 Enable function

4 Ramp generator

7 Controller for valve spool position

9 Oscillator
10 Demodulator

3 Command value summator

12

13

2 Differential amplifier

8 Current output stage

PID

M0

UB

1 Power supply unit

tmax

VT-MRPA2, VT-MRPA1

= Actual value

= Command value

Sw

Gw + Gw

= Actual value sensitivity

+ 15 V
+ 10 V
M0
10 V
15 V

14

t>

Zx

DC

UB

&

Gx

DC

11

Zw

= Command value zero point

L0

Zw

wR

Hydraulics

0V

+ UB

t<

Bosch Rexroth AG

Enable

Reference potential/GND

Command value: 10 V

Differential input (Ucomm):

t<

A negative command value causes an increase in current in solenoid


a and hence a flow in the valve from P to B and from A to T.

A positive command value causes an increase in current in solenoid


b and hence a flow in the valve from P to A and from B to T.

4/10

206
RE 30219/06.05

Block circuit diagram / pin assignment VT-MRPA2

Operating voltage

Gw

= Readiness for operation


= Enable

x
wR

= Ramp time up

= Ramp time down

= Step-change height

= Amplitude attenuator

t<

t>

Sw

Gw

= Command value after ramp

= Actual value

= Command value

= Actual value sensitivity

+ 15 V
+ 10 V
M0
10 V
15 V

14

t>

= Actual value zero point

DC

UB

&

t>

Zx

DC

11

Zw

Gx

L0

= Command value zero point

wR

Zw

t<

tmax

12

11

n.c.

n.c.

1
4

13 Inductive position transducer


14 Fault detection

7 Controller for valve spool position

12 Proportional valve
5 Characteristic curve generator

12

13

6 Amplitude limiter

11 Enable function
4 Ramp generator

9 Oscillator
10 Demodulator

8 Current output stage

Zx

10

3 Command value summator

Gx

UB

9
10

2 Differential amplifier

PID

M0

1 Power supply unit

Sw

VT-MRPA2, VT-MRPA1

0V

+ UB

Enable

Reference potential/GND

Command value: 0+10 V

Differential input (Ucomm):

t<

A positiver command value causes an increase in current in the solenoid

RE 30219/06.05

207
Hydraulics Bosch Rexroth AG
5/10

Block circuit diagram / pin assignment VT-MRPA1

01

208
6/10

Bosch Rexroth AG

Hydraulics

VT-MRPA2, VT-MRPA1

RE 30219/06.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC + 40 % 20 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 18 V

Power consumption

PS < 24 VA

Current consumption

I <2A

Fuse protection

Thermal overload protection (reclosing when the temperature


falls below the threshold)

Inputs:
Analogue
Command value (differential input) VT-MRPA2
VT-MRPA1

Ui 0 to 10 V, Ri > 50 k (current input on enquiry)


Ui 0 to +10 V, Ri > 50 k (current input on enquiry)

Digital
Enable

ON

U 8.5 V to UO, Ri > 100 k

OFF

U 0 to 6.5 V, Ri > 100 k

Adjustment ranges:
Command value zero point (potentiometer Zw)

30 %

Actual value zero point (potentiometer Zx)

10 %

Ramp times (potentiometers t < and t >)

20 ms to 5 s

Step-change height (potentiometer Sw)

0 % to 50 %

Amplitude attenuator (potentiometers G+ and G)

0 % to 110 % (valid for a step-change height setting of 0 %)

Outputs:
Current outputs

I 0 to 2.5 A; short-circuit-proof; clocked, approx. 5 kHz

Oscillator

USS 10 V; 10 mA
f 5.6 kHz 10 %

Measuring sockets
Ramp time t <

U 20 mV to 5 V

Ramp time t >

U 20 mV to 5 V

Actual value x

VT-MRPA2
VT-MRPA1

U 0 to 10 V
U 0 to +10 V

Command value w

VT-MRPA2
VT-MRPA1

U 0 to 10 V
U 0 to +10 V

Command value after ramp wR VT-MRPA2


VT-MRPA1

U 0 to 10 V
U 0 to 10 V

Type of connection

12 screw terminals

Type of mounting

Top hat rail TH 35-7.5 to EN 60715

Type of protection

IP 20 to EN 60529

Dimensions (W x H x D)

40 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +70 C

Weight

m 0.14 kg

Note!
Details with regard to environment simulation testing in the
fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 30219-U (declaration on environmental
compatibility).

209
RE 30219/06.05

Hydraulics Bosch Rexroth AG

VT-MRPA2, VT-MRPA1

7/10

Terminal assignment

VT-MRPA2
+UO

0 V1)

UE

Reference
potential

10

Ucomm

11

12

Operating voltage

Enable

Differential input

Position transducer, primary

VT-MRPA1

Solenoid
b

Solenoid

Solenoid
a

n.c.

4 Position
transducer,
3 secondary

4 Position
transducer,
3 secondary

01
1)

and position transducer, primary (connection 2)

Unit dimensions (nominal dimensions in mm)


Top hat rail TH 35-7.5
to EN 60715

LED indicator lamps:


Readiness for operation (green)
Enable (yellow)

7 8 9 10 11 12

Potentiometers:

79

REXROTH Gw+
VT-MRPAx -x
Gw
Sw
Zw
Zx
t<
t>
t< t>
x w
wR

1 2 3 4 5 6
85,5

40

Gw+ Amplitude attenuator for positive


command values
Gw

Amplitude attenuator for negative


command values (only with VT-MRPA2)

Sw

Step-change height for negative and positive direction

Zw

Command value zero point

Zx

Actual value zero point

t<

Ramp time for rising command values

t>

Ramp time for falling command values

Measuring sockets:
t<

Ramp time up

t>

Ramp time down

Actual value

Command value

wR

Command value after ramp

Measuring zero

210
8/10

Bosch Rexroth AG

Hydraulics

VT-MRPA2, VT-MRPA1

RE 30219/06.05

Engineering / maintenance notes / supplementary information


The amplifier module may only be wired when disconnected from the power supply!
Do not lay cables near power cables!
Do not use free-wheeling diodes in solenoid cables!
The distance to aerial lines, radio sources and radar equipment must be at least 1 m!
Always shield command value and position transducer cables; connect the shield to the protective earth (PE) on the module
side!
In individual cases (e.g. in the case of PE with severe interference) it may be required to connect the shield of the position transducer cable directly to L0 of the amplifier module; leave the other end open (risk of earth loops).
Recommendation:

Also shield solenoid cables!


For solenoid cables up to 50 m length, use cable type LiYCY 1.5 mm2!
For greater lengths, please consult us!

For passing on command values, use relays with gold-plated contacts (small voltages, small currents)!
Measurements on the module may only be taken with instruments Ri > 100 k.
To adjust the potentiometers, use a screw driver with a blade width of 4 mm!
In the case of strongly fluctuating operating voltages, it may be required to install an external smoothing capacitor having a
capacitance of at least 2200 F .
Recommendation: Capacitor module VT 11073 (see RE 29750), sufficient for up to 3 amplifier modules

211
RE 30219/06.05

VT-MRPA2, VT-MRPA1

Hydraulics Bosch Rexroth AG

9/10

Adjustment recommendation
The system-specific circuitry must be completed.

Signal

Setting for VT-MRPA2

Setting for VT-MRPA1

Command value
zero point

Set external command value feedforward to zero

Set external command value feedforward to zero

Set the internal command value to zero using zero


point potentiometer "Zw and check the setting at
measuring socket "wR"

Set the internal command value to zero using zero


point potentiometer "Zw and check the setting at
measuring socket "wR"

Actual value zero


point

Set enable signal to OFF or disconnect solenoid plug-in connector


(Valve moves to the mechanical centred position)

Set enable signal to OFF or disconnect solenoid plug-in connector


(Valve moves to end position)

Set the actual value at measuring socket x to


zero using potentiometer "Zx"

Set the actual value at measuring socket x to


zero using potentiometer "Zx"

Recommendation:
In the case of valves with V-spools, adjust the zero
point during operation with the hydraulic drive, i.e.

Recommendation:
In the case of valves with V-spools, adjust the zero
point during operation with the hydraulic drive, i.e.

Apply enable signal and check at measuring sock- Apply enable signal and check at measuring sockets "wR" and "w"
ets "wR" and "w"
Use potentiometer "Zx" to bring the hydraulic
drive to a standstill

Use potentiometer "Zx" to bring the hydraulic


drive to a standstill

Ramp times

Set ramp time according to formula or table (see


functional description Ramp generator) and
check at measuring sockets "t >" and "t <"

Set ramp time according to formula or table (see


functional description Ramp generator) and
check at measuring sockets "t >" and "t <"

Step-change
height

Apply enable signal

Apply enable signal

Set the measuring signal at wR to +0.3 V using


zero point potentiometer Zw

Set the measuring signal at wR to 0.3 V using


zero point potentiometer Zw

Set the required step-change height using potentiometer "Sw"

Set the required step-change height using potentiometer "Sw"

Set the measuring signal at wR to 0.3 V using


zero point potentiometer Zw

Maximum values

Check the required step-change height, adjust


zero point

Check the required step-change height, adjust


zero point

Note:
In the case of an external command value feedforward, at least +0.3 V / 0.3 V must be measured at
measuring socket "wR".

Note:
In the case of an external command value feedforward, at least 0.3 V must be measured at measuring socket "wR"

Note:
Before the maximum values are matched, the zero
point and step-change heights must have been correctly set.

Note:
Before the maximum values are matched, the zero
point and step-change heights must have been correctly set.

Adjust step-change heights first; generate


100 % command value externally

Adjust step-change heights first; generate


+100 % command value externally

Use potentiometers "Gw+"/"Gw" to adjust the


required maximum control output and check the
settings at measuring sockets "wR" and "w"

Use potentiometer "Gw" to adjust the required


maximum control output and check the settings at
measuring sockets "wR" and "w"

01

212
10/10

Bosch Rexroth AG

Hydraulics

VT-MRPA2, VT-MRPA1

RE 30219/06.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

213

RE 30222/07.05

Amplifier module
for proportional valves

1/6

Type VT-MSPA1

Unit series 1X

List of contents
Contents

Features
Page

Differential input for setpoint voltage 0...+10 V

Features

Ramp generator with separate adjustment for up and down

Ordering data

Zero potentiometer

Preferred types

Clocked output stage

Front panel

LED display:
Voltage supply
On standby
Ramp Off

Circuit diagram

Technical data

Unit dimensions

Removable edge connector

214
2/6

Bosch Rexroth AG

Hydraulics

VT-MSPA1

RE 30222/07.05

Ordering data

VT

Hydraulic component
For valves without electrical feedback
Valve type
Proportional valve
Actuation
Analog

1X V0

V0 =
=S
1X =

508 =
525 =

=A

=1

Preferred types

Type

Material Number

For valve types

VTMSPA152510/V0

0 811 405 127

see valve group A

VTMSPA150810/V0

0 811 405 126

see valve group B

Valve group A

Valve group B

DBETX...25

DBETX...8

DBE6X...25

DBE6X...8

DRE6X...25

DRE6X...8

DBE10Z...25

DBE10Z...8

DRE10Z...25

DRE10Z...8

2FREX10
3FREX6
3FREX10
4WRBA..EA

Unit series
Unit series 10 to 19

=P

Output stages
1 output stage

2FREX6

Customer version
Catalog version

Serial numbers for types


0.8 A solenoid
2.5 A solenoid

215
RE 30222/07.05

VT-MSPA1

Hydraulics Bosch Rexroth AG

3/6

Front panel

0...0.8 A
0...2.5 A

01

216
4/6

Bosch Rexroth AG

Hydraulics

Circuit diagram with pin assignment

VT-MSPA1

RE 30222/07.05

217
RE 30222/07.05

Hydraulics Bosch Rexroth AG

VT-MSPA1

5/6

Technical data
Specifications
P.C.B. format (W x L x H)
Plug connector
Ambient temperature
Power supply UB to (7) (6)

Valve solenoid
Max. current rating

VT-MSPA1-508-10/V0

VT-MSPA1-525-10/V0

mm (86 x 110 x 70)


10-way connector (screw terminal)
C 0...+70, storage temperature min. 20; max. +70
24 V DC nominal
Battery voltage 21...40 V
Rectified AC voltage
Ueff = 21...28 V (single-phase, full-wave rectification)
A/VA 0.8/25

2.5/55

A 1.25

2.5

This value can rise in the event of min. UB


and an extremely long cable to the control solenoid
Max. Power consumption

VA 30

60

Setpoint

(2): 0...+10 V
(1): 0 V
(Ri = 100 k)

Setpoint source

Potentiometer 10 k
Supply +10 V from (5) (10 mA)
or external signal source

Solenoid output
(9) (10)

Clocked current regulator

} Differential input

A Imax = 0.8

Imax = 2.5
mm2

Cable lengths between amplifier


and valve

Solenoid cable: up to 20 m 1.5


20 to 50 m 2.5 mm2

LED displays

Green: enable
Yellow: ramp OFF
Red: undervoltage (UB too low)

External ramp shut-off

(3): 6...40 V DC (24 Vnom)

Ramp times

s 0.05...5

Adjustment possibilities

Valve zero, ramp times, sensitivity, dither amplitude

Special features

Short-circuit proof inputs and outputs, clocked output stage, rapid energizing for
fast response times

Notes on the use of ramps


Ramp UP (accelerate) and ramp DOWN (decelerate) are each set by a trimming potentiometer.
Ramp ON if (3) = 0 V (open). Ramp OFF if (3) = 24 Vnom (min.: 6 V high).
Ramp OFF interrupts a ramp in progress.
There is an abrupt transition to the final signal value.
Zero adjustment: at 0.5 V signal (min. 0.3 V)
Max. adjustment: at +10 V signal.

01

218
6/6

Bosch Rexroth AG

Hydraulics

VT-MSPA1

RE 30222/07.05

Unit dimensions (nominal dimensions in mm)

Wall mounting

Rail mounting

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

VT-MSPA1-508-10/V0
VT-MSPA1-525-10/V0
(86 x 110 x 70) mm

DIN rail mounting (snap-in)

Wall mounting

Supplied loose

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not release
the user from the obligation of own judgement and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

219

RE 30223/06.05
Replaces: 07.03

Analogue amplifier module

1/6

Type VT-MSPA1-1

Series 1X

H6833_d

Table of contents

Features

Features

Suitable for controlling direct operated proportional pressure


control valves (type DBET..., series 6X and type KBPS...)

Ordering code

Polarity reversal protection of the operating voltage

Functional description

Differential input for command value voltage +10 V

Block circuit diagram

Ramp generator can be adjusted separately for up and down


ramps

Contents

Page

Connectional allocation / component view

Technical data

Output characteristic curve

Engineering / maintenance guidelines / additional information

Zero point potentiometer


1 command value attenuator
Characteristic curve generator
Clocked output stage
Short-circuit-proof output
LED display:

Ready for operation (green)

Measuring sockets for:

Pressure command value


Actual current value

Dither generator with command value and operating


voltage-related frequency

Information on available spare parts:


www.boschrexroth.com/spc

220
2/6

Bosch Rexroth AG

Hydraulics

VT-MSPA1-1

RE 30223/06.05

Ordering code

VT-MSPA1

1X V0

Analogue amplifier module


For controlling valves of type DBET... series 6X and KBPS...

Further details in clear text


Standard version

=1

Series 10 to 19
= 1X
(10 to 19: unchanged technical data and connection allocation)

Functional description
Analogue amplifier for controlling pressure control valves
without electrical feedback. The modular design allows simple
mounting on top-hat rails, which are usually provided in control
cabinets.

Clock-pulse generator: 12
Clock-pulse generator (12) generates a frequency matched to
the command value for the output stage.
Current output stage: 11-14

Command value input: 4


The modular amplifier is controlled by a standard command
value signal ranging from 0 to +10 V. The zero point potentiometer (Zw) (6) can be used to correct a zero point offset.
Ramp generator: 5
Ramp generator (5) limits the gradient of the control variable.
Trimming potentiometer t < (7) is used to adjust the time for
the increasing the command value signal, trimming potentiometer t > (8) is used for decreasing the command value voltage.
The settable time ranges from 30 ms to > 5 s each.
Characteristic curve generator: 10
The trimming potentiometer Gw (9) is used to adjust the rated current of 1.6 A for the solenoid. The command value signal is so changed in the characteristic curve generator (10) to
achieve a linear command value/pressure characteristic curve.

The current output stage generates a PWM signal from the


control variable that is provided by characteristic curve generator (10) and the clock-pulse frequency, which is then fed to the
solenoid. The solenoid current is sensed and compared with
the control variable in current regualator (11), and the difference
is then balanced.
Fault detection: 15
Monitors the solenoid cables for cable break and short-circuit
as well as the output stage for over current. If a fault is present,
the green LED that indicates readiness for operation goes out.

221
RE 30223/06.05

Hydraulics Bosch Rexroth AG

VT-MSPA1-1

3/6

Block circuit diagram

+UB
24 V

14
1

11

DC

0V

T
13

DC

15

GND

6
Zw

t<

t>

10

U
4

01

Gw

U
Command value
+10 V 6

Power

I>

12

16

Fuse

Ramp down potentiometer

15 Fault detection

Suppressor diode

Imax potentiometer

16 Measuring socket

Power supply unit

10 Linearisation

Command value input

11 Current regulator

Ramp generator

12 Oscillator

Zero point potentiometer

13 Schmitt trigger

Ramp up potentiometer

14 Output stage

On front panel

Connectional allocation / component view


Connection allocation

Component view

4 5 6

Terminal

Potentiometer: Gw

Pressure command
value

+UB

Ground

Rexroth

Zw

Zero point

Ucomm

VT-MSPA1-1

t <

Ramp time up

t >

Ramp time down

Pressure command
value

Actual current
value

Measuring zero

Solenoid +

Solenoid

+Ucomm

E
Gw
Zw
t<
t>
wI

1 2 3

Buchsen:

222
4/6

Bosch Rexroth AG

Hydraulics

VT-MSPA1-1

RE 30223/06.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UB 24 VDC +40% 10%

Functional range:
Upper limiting value

uB(t)max 35 V

Lower limiting value

uB(t)min 21 V

Power consumption

Pmax < 50 VA

Current consumption

Imax < 1.3 A

Fuse

Is Electronic overload fuse and SMD fuse (soldered in)

Inputs:
Command value (differential input)

Ucomm 0 to +10 V; Re = 100 k

Outputs:

Imin 0.1 A

Solenoid current / resistance

Imax 1.9 A; R20 = 5.5

Frequency

f 180 to 450 Hz

Settable range:
GW: Solenoid current
ZW:
t >:
t <:

I 100 mA1,9 A
25 %

Ramp

t 60 ms5 sec

Measuring sockets:
Command value w
Actual current value I
Connection type

U 0 to 10 V
U 1 mV
=1 mA solenoid current
6 screw terminals

Mounting style

TH 377.5 carrier rail to EN 60715

Protection type

IP 20 to EN 60529

Dimensions (W x H x D)

25 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +85 C

Weight

m 0.15 kg

223
RE 30223/06.05

Hydraulics Bosch Rexroth AG

VT-MSPA1-1

5/6

Output characteristic curve

1600

Output current in mA

1400
1200
1000
800
600

01

400
200

10

20

30

40

50

60

70

80

90

100

Command value in %

Engineering / maintenance guidelines / additional information


The amplifier module may only be wired when disconnected from the power supply!
Ensure a sufficient distance from radio equipment (>> 1 m)!
Shield command value cables and do not install them near power cables; sheild solenoid cables!
Do not use free-wheeling diodes in solenoid cables!
In the case of a heavily fluctuating operating voltages it may be required to use a smoothing
capacitor with a capacitance of at least 2200 F.
Recommendation: Capacitor module VT 11073 (see RE 29750); sufficient for up to 3 amplifier modules.

224
6/6

Bosch Rexroth AG

Hydraulics

VT-MSPA1-1

RE 30223/06.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

225

RE 30 225/01.04
replaces: 06.01

Analogue amplifier module

1/4

Type VT-MSPA1-50

Series 1X

HAD6785

Table of contents

Features

Contents

Page

Features

Ordering code

Functional description

Block circuit diagram / Pin assignment

Terminal assignment

Technical data

Output curve

Unit dimensions

Engineering notes / Maintenance notes /


Supplementary information

Suitable for controlling of one proportional solenoid; especially


of direct operated proportional directional valves in screw-in
cartridge valve technology; types KKS1NA and KKS1PA
Differential input
One pulsed output stage
Ramp generator; ramp times up and down separately adjustable
Reverse polarity protection for power supply
Adjustable maximal current
Adjustable current step
Zero point potentiometer

Suitable power supply unit:

Measuring sockets for actual value and command value of


current

Type VT-NE30-1X, see RE 29 929


compact power supply unit 115/230 VAC > 24 VDC, 70 VA

LED lamp Ready for operation (green)

Ordering code
VTMSPA150 1X V0

Further details in clear text

Analogue amplifier in modular design


for controlling of one proportional solenoid
Series 10 to 19
(10 to 19: unchanged technical data and pin assignment)

Basic version
= 1X

226
2/4

Bosch Rexroth AG

Industrial Hydraulics

RE 30225/01.04

VT-MSPA1-50

Functional description
General

Characteristic curve generator [5]

The amplifier module is to be snapped onto carrier rails according to DIN 50 022.The electrical connection is by means of
screw terminals. The module is operated using 24 VDC.

The adjustable characteristic curve generator can be used to


adjust
the step-change height and maximum values to the hydraulic
requirements.

The internal power supply unit provides all internally required


positive and negative supply voltages. As soon as the power
supply unit is in operation, the green LED (Ready for operation) lights up.

Clock-pulse generator [6]


The clock pulse generator generates the clock frequency and
feeds it to the output stage.

Command value preselection


The internal command value signal is generated by the sum
[3] of the external command value signal applied to differential
input [2] and the zero point offset (zero point potentiometer
Zw).
Ramp generator [4]

Current output stage [7]


The current output stage generates the pulsed solenoid current
for the proportional valve. The solenoid current is 2.5 A. The
output stage output is short-circuit-proof.
Fault detection [8]

The ramp generator limits the gradient of the control variable. Due to the characteristic curve generator connected
downstream, the ramp time is not extended or shortened. The
ramp time can be set separately for up and down ramps
with the help of potentiometers (t < and t >).

The solenoid cables are monitored for cable break and shortcircuit and the output stage for overcurrent. In the case of an
error, the green LED flashes.
[ ] = Cross-reference to the block circuit diagram

Block circuit diagram / Pin assignment


t<

Differential input
(Ucomm):

Comm. value: 0 to 10 V 6

Reference potential/ 3
GND

UB

Sw
w

9
t>

Zw

Gw

=
&

UB
1
Operating- + UB
voltage
2
0V

DC
DC
1

1 Power supply unit


2 Differential amplifier
3 Command value summator

Zw = Zero point of command value


t < = Ramp time up
Gw = Max. command value
t > = Ramp time down
w = Command value
Sw = Step-change height
I
= Actual current value

4 Ramp generator
5 Characeristic curve generator
6 Clock-pulse generator

7 Current output stage


8 Fault detection
9 Proportional valve

Terminal assignment
Operating
voltage

+ UB

0V

Reference
potential

6 Ucomm

Terminals 3 and 6: Differential input

Proportional
solenoid

227
RE 30225/01.04

Industrial Hydraulics Bosch Rexroth AG

VT-MSPA1-50

3/4

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UB 24 VDC + 40 % 10 %

Operating range:
Upper limit value

uB(t)max 35 V

Lower limit value

uB(t)min 21 V

Current consumption (at UB= 24 V)

Imax 2 A

Power consumption

PS max. 50 VA

Fuse

Electronic overload protection of the output stage

Inputs:
Ucomm 0 to + 10 V; Re approx. 100 k

Command value (differential input)


Adjustment ranges:
Zero point of command value (potentiometer Zw)

10 %

Max. command value (potentiometer Gw)

0 bis 110 %

Ramp times (potentiometer t < and t >)

approx. 50 ms to approx. 5 s

Step-change height (potentiometer Sw)

0 bis 50 %

Outputs:
Current output stage
Imax 2,5 A; R(20) = 2

Solenoid current / resistance


Clock-pulse frequency

f 360 Hz 15%

Measuring sockets
Command value w

U 0 to 10 V

Actual current value I

U 0 to 2,5 V (mV = mA)

Type of connection

6 threaded terminals

Type of mounting

Carrier rail NS 35/7,5 to DIN 50 022

Insulation

IP 20 to DIN 40 050

Dimensions (W x H x D)

25 x 79 x 85,5 mm

Permissible operating temperature range

0 to + 50 C

Storage temperature range

20 to + 70 C

Weight

m 0,13 kg

Note!
For details on environment simulation tests in the fields of EMC (electromagnetic compatibility), climate and mechanical stress,
see RE 30 225-U (declaration on environmental compatibility).

Output curve

Output current in A >

2,5
2,0
1,5
1,0
0,5

20

40

60

80

Command value in % >

100

01

228
4/4

Bosch Rexroth AG

Unit dimensions

Industrial Hydraulics

VT-MSPA1-50

RE 30225/01.04

(Dimensions in mm)
Carrier rail NS 35/7.5
to DIN 50 022
4 5 6

Potentiometer:

REXROTH

Gw Max. command value

VT-MSPA1-50

Sw Step-change height of internal command value


Zw Zero point of command value
t < Ramp time for increasing command values
t > Ramp time for decreasing command values
Messbuchsen:

w I

1 2 3
85,5

25

Command value

Actual current value

79

Gw
Sw
Zw
t<
t>

Reference potential

Engineering notes / Maintenance notes / Supplementary information


The amplifier module may only be wired when disconnected from the power supply!
The distance to radio sources must be adequate (>> 1 m)!
Shield command value cables, do not lay in the vicinity of power cables!
Do not connect freewheel diodes in the solenoid lines!
In the case of heavy fluctuations in the operating voltage,it may become necessary to install an external
smoothing capacitor having a capacitance of at least 2200 F.
Recommendation: Capacitor module type VT 11 073 (see RE 29 750); sufficient for up to 3 amplifier modules
For solenoid cables up to 50 m long, use cable type LiYCY 1.5 mm2. In the case of greater lengths, please consult us!
The inputs of the differential amplifier must always be switched on or off simultaneously!
Use relays with gold-plated contacts for passing on command values (small voltages, small currents)!
Use only instruments Ri > 100 k for taking measurements on the module!
For adjusting the potentiometers, use a screw driver with a blade width of 2,5 mm to 3,5 mm!
Adjustment of step-change heights:
1. Turn potentiometer Sw to the left-hand limit stop
2. Preselect a command value of 0.5 V using zero point potentiometer Zw (measuring socket w)
3. Set the required step-change height using potentiometer Sw; check the value in measuring socket w
4. Apply 0 V to the differential input
5. Set 0 V in measuring socket w using the Zw potentiometer (zero point balancing)

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

2003 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, diplicated or circulated using electronic systems, in any form
or by means, without the prior written authorisation of Bosch Rexroth AG,
Industrial Hydraulics. In the event of contravention of the above provisions,
the contravening party is obliged to pay compensation.
The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The details stated do not release the
user from the responsibility for carrying out their own assessment and verification. It must be remembered that our products are subject to a natural
process of wear and ageing.

229

RE 30228/07.04

Analogue amplifier module

1/8

Type VT-MSPA2-1

Series 1X

H 7282

Table of contents

Features

Contents

Page

Features

Ordering code

Functional description

Block circuit diagram

Technical data

Terminal assignment

Characteristic curve correction through separately adjustable


jump heights and separately adjustable maximum values

Unit dimensions

Enable input

Adjustment recommendation

Reverse polarity protection for voltage supply

Engineering / maintenance notes / supplementary information 6

Suitable for controlling direct operated proportional directional


valves without electrical position feedback
(type 4WRA, sizes 6 and 10, series 2X)
Command value input 10 V (differential input)
Ramp generator with separately adjustable up/down ramp
times

Power supply unit with DC/DC converter without raised zero point
LED lamps:

Readiness for operation (green)


Enable (yellow)

Output for readiness of operation (on enquiry)


Output stage OFF OSO output (on enquiry)
or
Command value reached I

wi output (on enquiry)

Operating mode selector switch S


Suitable power supply unit:
Type VT-NE30-1X, see RE 29 929
Compact power supply unit 115/230 VAC > 24 VDC, 70 VA

230
2/8

Bosch Rexroth AG

Industrial Hydraulics

VT-MSPA2-1 RE 30228/07.04

Ordering code
VT-MSPA2

1X V0

*
Further details in clear text

Analogue amplifier of modular design


0=

for controlling valve types 4WRA6 (series 2X) and 4WRA10


(series 2X)
=1
Series 10 to 19
(10 to 19: unchanged technical data and connections)

Basic version

V0 =

Basic version

= 1X

Functional description
General
The amplifier modules are snapped onto carrier rails according
to DIN 50022.
The electrical connection is made by means of screw terminals.
The modules are operated with 24 V DC voltage.

The following is valid:


Example:

t=

100Vms
Ut

Measured

Ut = 5V

results in

Power supply unit [1]


The amplifier modules are provided with a power supply unit
with making current limiter. It supplies all the internally required
positive and negative voltages. The making current limiter prevents excessive making current peaks.
Command value feedforward
The internal command value signal is the sum [3] of the external command value signal applied to the differential input [2]
and the zero point offset (zero point potentiometer Zw).
A positive command value results in an increase in current in
solenoid b and causes an oil flow from P to A and from B to
T in the valve.
A negative command value results in an increase in current in
solenoid a and causes an oil flow from P to B and from A to T
in the valve.
Enable function [11]
The enable function enables the current output stages and
passes the internal command value signal on to the ramp generator. The enable signal is indicated by an LED on the front
panel. When the enable is cut in, the internal command value
changes (with any command value selection) with the set ramp
time. In this way, a controlled valve does not open suddenly.

t=

100Vms
5V

Characteristic curve generator [5]


The adjustable characteristic curve generator can be used to adapt
jump heights and maximum values separately for positive and negative
signals to suit the hydraulic requirements. The actual line of the characteristic curve through the zero point is not step-like, but linear.
Amplitude limiter [6]
The internal command value is limited to approx. 110 % of
the nominal range.
Current regulator [7]
Current output stage [8]
The current output stage generates the clocked solenoid current for the proportional valve. The solenoid current is limited
to 2.7 A per output. The output stage outputs are short-circuitproof. The output stages are de-energized in the case of an
internal fault signal or missing enable.
Clock generator [9]
The clock generator generates clock frequency f of the
output stages. Three basic frequencies can be set by means of
the operating mode selector switch:
S = 1:

f = 150 Hz 400 Hz adjustable

Ramp generator [4]

S = 2:

f = 380 Hz 180 Hz 15% (WRA 10)

The ramp generator limits the gradient of control output. The


downstream jump functions and amplitude attenuator do not
extend or shorten the ramp time.

S = 3:

f = 350 Hz 240 Hz 15% (WRA 6)

Notes on the adjustment and measurement of the ramp time:


Value at measuring socket "t <" or "t >" Ut in V

Current ramp time ( 20 %)

20 33 50

t in ms
0.1

Ut in V

0.5

0.3

0.2

t in ms

100

200

333

500 1000 2000 3333 5000

= 20 ms

When the setting for WRA valves was selected, the frequency
changes in dependence upon the command value and the
operating voltage.
Fault detector [11]
Monitors the solenoid cable for cable break and overcurrent of
the output stage.

0.05 0.03 0.02


Command value inversion [12]
The command value that is generated internally from the input
signal and the zero point offset signal can be inverted by an
external signal.

IN

0V

U
U

-1

(6)

(11)

11 Fault detector
12 Inverter
6 Amplitude limiter

10 Enable function
5 Characteristic curve generator

4 Ramp generator
= Enable

Gw = Amplitude attenuator

Sw = Jump height

9 Clock generator

= Ready for operation

t< = Ramp time down

8 Current output stage

7 Current regulator

UL

3 Command value summator

&

ok

2 Differential amplifier

Fault detector

1
2
3

1 Power supply unit

UL

Sw-

(5)

ok

wR = Comm. value after ramp

-10V

M0

+15V
+10V

Sw+

Gw-

w = Command value

DC

Gw+

(4)

t< = Ramp time up

(1)

DC

Zw

ok

(7)

Regultaor

U
(8)

Zw = Comm. value zero point

(3)

wR

-15V

(2)

M0

100uF

L0

(10)

(12)

>50k

>50k

t<

t<

(9)

>

12

7
8
9
10

Ready for operation ok (on


enquiry)

Solenoid A

Solenoid B

OSO / I w
(on enquiry)

VT-MSPA2-1

24 V

Enable

Inversion 6

10 V

5
Comm. valueIN+

t>

t>

&

11

RE 30228/07.04

231
Industrial Hydraulics Bosch Rexroth AG
3/8

Block circuit diagram

01

232
4/8

Bosch Rexroth AG

Industrial Hydraulics

VT-MSPA2-1 RE 30228/07.04

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC + 40 % 20 %

Operating range:
Upper limit vaue

uO(t)max 35 V

Lower limit value

uO(t)min 18 V

Power consumption

PS < 48 VA

Current consumption

I <2A

Fuse

Thermal overload protection (with automatic reactivation when


the tempeature falls below the threshold)

Inputs:
analogue
Command value (differential input)

Ue 0 to 10 V; Ri > 50 k (current input on enquiry)

digital
Enable
Inversion

ON

U 8.5 V to UO; Ri > 100 k

OFF

U 0 to 6.5 V; Ri > 100 k

ON

U 8.5 V to UO; Ri > 100 k

OFF

U 0 to 6.5 V; Ri > 100 k

Adjustment ranges:
Clock frequency f

S = 1 150 Hz 400 Hz adjustable


S = 2 380 Hz 180 Hz 15% (WRA 10)
S = 3 350 Hz 240 Hz 15% (WRA 6)

Command value zero point (potentiometer Zw)

30 %

Ramp times (potentiometers t < and t >)

20 ms to 5 s

Jump height (potentiometers Sw+ and Sw)

0 % to 50 %

Amplitude attenuator (potentiometers G+ and G)

0 % to 110 % (valid for jump height setting of 0 %)

Outputs:
Current output stages

I 0 to 2,5 A; short-circuit-proof; clocked

Ready for operation (on enquiry)

U > 16 V, 50 mA (in the case of a fault U < 1 V, Ri = 10 k)

Output stage OFF OSO (on enquiry)

U > 16 V, 50 mA (with output stage ON U < 1 V, Ri = 10 k)

Command value reached I

wi (on enquiry)

U > 16 V, 50 mA (if command value is not reached U < 1 V, Ri = 10 k)

Measuring sockets
Ramp time t <

U 20 mV to 5 V

Ramp time t >

U 20 mV to 5 V

Actual vaue I

U 0 to 2.5 V (mV = mA)

Command value w

U 0 to 10 V

Command value after ramp wR

U 0 to 10 V

Type of connection

12 screw terminals

Type of mounting

NS 35/7.5 carrier rails to DIN 50 022

Type of protection

IP 20 to DIN 40 050

Dimensions (W x H x D)

40 x 79 x 85.5 mm

Permissible operating temperature range

0 to + 50 C

Storage temperature range

25 C to + 70 C

Weight

m 0.14 kg

233
RE 30228/07.04

Industrial Hydraulics Bosch Rexroth AG

VT-MSPA2-1

5/8

Terminal assignment

Operating
voltage

Enable

Differential input

+UO

0V

UF

Reference
potential

10

Ucomm

11

Output stage OFF OSO /


i = wi (on enquiry)

Inversion

12

Ready for operation


(on enqiry)

Solenoid
B

Solenoid A

01

Unit dimensions (dimensions in mm)


LED lamps:

Potentiometers:
Gw+ Amplitude attenuator for positive command values

Readiness for operation (green)

Gw Amplitude attenuator for negative command values

Enable (yellow)

Sw+ Jump height for positive direction


7 8 9 10 11 12
REXROTH
VT-MSPA2-1

79

f
1
2
3

Zw

Command value zero point

Gw+
Gw
Sw+
Sw
Zw
t<
t>

t<

Ramp time for increasing command values

t>

Rampe time for falling command vaues

Frequency adjustment

t<

Ramp time up

t< t>
I w
wR

t>

Ramp time down

Actual current value

1 2 3 4 5 6
85,5

Operating mode selector switch

Sw Jump height for negative direction

40

Measuring sockets:

Command value

wR

Command value after ramp


Measuring zero

1: General application with Imax = 2.5 A; f = 150 Hz 400 Hz


2: Frequency optimised for WRA 10
3: Frequency optimised for WRA 6

234
6/8

Bosch Rexroth AG

Industrial Hydraulics

VT-MSPA2-1 RE 30228/07.04

Engineering / maintenance notes / supplementary information


The amplifier may only be wired when disconnected from the power supply!
Do not install cables near power cables!
Do not use free-wheeling diodes in solenoid cables!
The distance to aerial lines, radio equipment and radar systems must be at least 1 m!
Always shield command value cables; connect shield to protective earth (PE) on the module side!
Recommendation:
Also shield solenoid cables!
For solenoid cables up to 50 m length, use cable type LiYCY 1.5 mm2!
In the case of greater lengths, please consult us!
For switching command values, use relays with gold-plated contacts (small voltages, small currents)!
Use only instruments with Ri > 100 k for measurements on the module.
For potentiometer adjustments, use a screw driver with a blade width of 4 mm!
In the case of strongly fluctuating operating voltage, it may be required to use an external smoothing capacitor with a capacitance of at least 2200 F .
Recommendation:
Capacitor module VT 11 073 (see RE 29 750); sufficient for up to 3 amplifier modules
The factory setting of the clock frequency meets the requirements of WRA 6 and WRA 10 valves. Turning of potentiometer f
results in a change in the valve hysteresis and can cause annoying noise emission.

Adjustment recommendation
The system-specific connections must have been made
Signal

Setting

Command value

Set external command value feedforward to zero

zero point

Set the internal command value to zero with the help of the Zw zero point potentiometer and check the
setting at measuring socket "wR"

Ramp times

Set the ramp time according to the formula or table (see functional description of ramp generator) and
check the setting at measuring sockets "t >" and "t <"

Jump height

Apply enable signal


Set the measuring signal at "wR" to + 03 V using the Zw zero point potentiometer
Use the "Sw+" potentiometer to set the required positive jump height
Set the measuring signal at "wR" to 0.3 V using the Zw zero point potentiometer
Use the "Sw" potentiometer to set the required negative jump height
Adjust zero point
Note:
In the case of external command value feedforward, the voltage at measuring socket wR must be at least
+0.3 V / 0.3 V.

Maximum values

Note: Before maximum values can be matched, the zero point and jump heights must be correctly set.
The maximum current must not exceed the nominal current of the solenoids!
Adjust the jump heights first; generate command value 100 % externally
Adjust the required maximum control output using potentiometers "Gw+"/"Gw" and check this at
measuring sockets "wR" and "w"

Clock frequency:

Factory setting:
S = 1: f = 170 Hz
S = 2 and w = 0: f = 380 Hz
S = 3 and w = 0: f= 350 Hz

Note:

The frequency can be set using a digital multimeter that is capable of measuring frequencies.
Measurement at solenoid terminals 7 against ground 2, or 9 against 2.

235
RE 30228/07.04

VT-MSPA2-1

Industrial Hydraulics Bosch Rexroth AG

7/8

Notes

01

236
8/8

Bosch Rexroth AG

Industrial Hydraulics

VT-MSPA2-1

RE 30228/07.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

2004 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, duplicated or circulated using electronic systems, in any form
or by any means, without the prior written authorisation of Bosch Rexroth
AG. In the event of contravention of the above provisions, the contravening
party is obliged to pay compensation.
The data specified only serves to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The details stated do not release you from the
responsibility for carrying out your own assessment and verifcation. It must
be remembered that our products are subject to a natural process of wear
and ageing.

237

Amplifier module for controlling 1)


explosion-protected
proportional directional valves
4WRA...XE, 3DREP 6...XE and 4WRZ...XE

RE 30228-200/07.05 1/8

Type VT-MSPA2-200

Component series 1X

H 7282

Table of contents
Contents

Features
Page

Features

Ordering code

Functional description

Amplifier is not subject to


Directive 94/9/EC (ATEX Directive)

Block circuit diagram

In conjunction with Rexroth safety module VT-MUXA2, suitable


for controlling proportional directional valves without electrical position feedback, types 4WRA...XE, 3DREP 6...XE and
4WRZ...XE

Technical data

Command value input 10 V (differential input)

Characteristic curves

Ramp generator with separately adjustable up/down ramp times

Terminal assignment

View / unit dimensions

Characteristic curve correction through separately adjustable


step-change heights

Important notes / adjustment recommendations

Enable input
Reverse polarity protection for voltage supply
Power supply unit with DC/DC converter without raised zero
point for internal supply

1)

LED lamps:
To achieve the prescribed level of safety when operating
one of the listed valves in a potentially explosive atmosphere, this amplifier module must be connected to safety
module VT-MUXA2.
In this context, read operating instructions RE 30290-B0
for the safety module!

Ready for operation (green)


Enable (yellow)

Suitable power supply units:


If power is to be provided also for safety module VT-MUXA:
Type VT-NE40-1X to data sheet RE 29891,
permissible ambient temperature 40 C
Without supply of safety module VT-MUXA:
Type VT-NE30-1X to data sheet RE 29929

238
2/8

Bosch Rexroth AG

Hydraulics

VT-MSPA2-200 RE 30228-200/07.05

Ordering code
VT-MSPA2 200 1X V0

Analogue amplifier of modular design

Further details in clear text

for controlling explosion-protected valves


4WRA...XE (component series 2X),
3DREP 6...XE (component series 2X)
and 4WRZ...XE (component series 7X)

0=

Basic version

V0 =

Basic version

= 200

Component series 10 to 19
(10 to 19: unchanged installation and connection dimensions)

= 1X

Functional description
General
The amplifier modules are to be snapped onto hat rails according to EN 60715. They are electrically connected by means of
screw terminals. The modules are operated with 24 V DC.

The following is
valid:
Example:

t=

Measured

Power supply unit (1)


The amplifier modules are shipped with a power supply unit
with switch-on current limitation. It provides all internally
required positive and negative supply voltages. The switch-on
current limitation prevents excessive switch-on current peaks.
Command value
The internal command value signal is generated from the external command value signal applied to differential input (2).
A positive command value causes in increase in current in
solenoid b and therefore a flow in the valve from P A and
from B T.
A negative command value causes in increase in current in
solenoid a and therefore a flow in the valve from P B and
from A T.

results in

100 Vms
Ut
Ut = 5 V
t=

100 Vms
5V

= 20 ms

Characteristic curve generator (4)


The adjustable characteristic curve generator can be used to
adjust the step-change height separately for positive and negative signals to the requirements of the hydraulic system. The
actual course of the characteristic curve through the zero point
is not stepped, but linear. (Characteristic curve, see page 5)
Amplitude limiter (5)
The command value is limited to approx. 110 % of the nominal range.
Current regulator (6)
The current is regulated in dependence upon the command
value.

Enable function (10)


The enable function is used for enabling the current output
stages and passing the internal command value signal on to
the ramp generator. The enable signal is signalled by an LED
on the front panel. When the enable is granted, the internal
command value (with optional command value feedforward)
changes with the set ramp time. A valve does therefore not
open suddenly when activated.
Ramp generator (3)
The ramp generator limits the gradient of the control output.
The downstream step functions do not extend or shorten the
ramp time.
Note on the adjustment and measurement of the ramp time:
Value at measuring socket "t <" or "t >" Ut in V

Current ramp time ( 20 %)

20 33 50

t in ms
0.1

Ut in V

0.5

0.3

0.2

t in ms

100

200

333

500 1000 2000 3333 5000

0.05 0.03 0.02

Current output stage (7)


The current output stage generates the clocked solenoid current for the proportional valve. The nominal solenoid current
is 1000 mA per output. The output stage outputs are shortcircuit-proof. In the event of an internal fault signal or missing
enable, the output stages are de-energised.
Clock-pulse generator (8)
The clock-pulse generator generates clock frequency f of the
output stages.
f = 150 Hz 400 Hz, adjustable with the help of potentiometer f (pre-set to 240 Hz)
Fault detector (10)
Monitors the solenoid cables for cable break and the output
stage for overcurrent.
Command value inversion (11)
The command value generated from the input signal and the
zero point offset signal can be inverted by means of an external
signal.

>50k

>50k

-1

(11)

L0

(9)

(2)

Ramp time down


Ramp time up
Step-change height
Command value
Command value after ramp

0V

()

VT-MSPA2-200

100F

DC

(1)

Sw+

t<

Sw-

t<

Enable

Ready for operation

DC

ok

t>

t>

-15V

-10V

M0

+15V
+10V

(3)

UL

wR

(1)
(2)
(3)
(4)
(5)
(6)
(7)

(10)

(5)

&

(6)

ok

S
1
2
3

ok

Power supply unit


Differential amplifier
Ramp generator
Characteristic curve generator
Amplitude limiter
Current regulator
Current output stage

(4)

M0

(8)

9
10
7
8

(13)
13
14
15
16

VT-MUXA2-1
9
10
11
12

Explosion-protected section

Clock-pulse generator
Enable function
Fault detection
Inversion
Safet module
(to be ordered separately)
(13) Two ferrite sleeves (included only in the
scope of suply of the safety module)

(8)
(9)
(10)
(11)
(12)

(7)

(12)

Not explosion-protected section

VT-MSPA2-200

t>
t<
Sw
w
wR

24 V

Enable

Inversion

(UO)

(+IN) 10 V
Command value
(IN) 0 V

(12)

VT-MUXA2-1

RE 30228-200/07.05

239
Hydraulics Bosch Rexroth AG
3/8

Block circuit diagram

01

240
4/8

Bosch Rexroth AG

Hydraulics

VT-MSPA2-200 RE 30228-200/07.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

Nominal value

UO 24 VDC

Maximum value

uO(t)max 35 V

Minimum value

uO(t)min 18 V

Power consumption

P < 24 VA

Current consumption

I <1A

Fuse

Thermal overload fuse (with reset when temperature falls


below a threshold )

Inputs
Analogue

Command value (differential input)

Ui 0 10 V; Ri > 50 k

Digital

Enable

ON

U 8.5 V UO; Ri > 100 k

OFF

U 0 6.5 V; Ri > 100 k

ON

U 8.5 V UO; Ri > 100 k

OFF

U 0 6.5 V; Ri > 100 k

Inversion
Adjustment ranges
Clock frequency

f adjustable from 150 Hz 400 Hz, preset to 240 Hz

Ramp times (potentiometers t < and t >)

t < , t > 20 ms 5 s

Step-change height (potentiometers Sw+ and Sw)

0 % 50 %

Outputs
Current output stages

I 0 to 1000 mA, short-circuit-proof; clocked

Measuring sockets Ramp time t <

U 20 mV 5 V

Ramp time t >

U 20 mV 5 V

Actual value I

U 0 1000 mV (value measured in mV

Command value w

U 0 10 V

Command value after ramp wR

U 0 10 V

Type of connection
Connection cross-section

Screw terminals
A 0.5 2.5 mm2

Type of mounting

Hat rail TH 35-7.5 to EN 60715

Type of protection

IP 20 to EN 60529

Dimensions (W x H x D)

See unit dimensions

Permissible operating temperature range

0 +50 C

Storage temperature range

25 C +70 C

Weight

m 0.14 kg

solenoid current in mA)

241
RE 30228-200/07.05

Hydraulics Bosch Rexroth AG

VT-MSPA2-200

5/8

Characteristic curves
Dependence of output current on command value voltage

Solenoid b

Solenoid a

Output current in mA

1000
800
600
500
400

01

200
150
10

0
+2
0,2 +0,2

+4

+6

+8

Command value voltage in V


Adjustment range of step-change height of output current: 0 500 mA
Factory setting:
150 mA

+10

242
6/8

Bosch Rexroth AG

Hydraulics

VT-MSPA2-200 RE 30228-200/07.05

Terminal assignment

+UO

0V

UF

0V ( IN )

10

10V (+IN)

11

n.c.

Inversion

12

n.c.

Operating
voltage

Solenoid b

Enable

Solenoid a
Command
value input

View / unit dimensions (nominal dimensions in mm)

7 8 9 10 11 12
REXROTH

VT-MSPA2-200

Sw+
Sw

79

f
1
2
3

t<
t>
t< t>
I w
wR

1 2 3 4 5 6
85,5

LED indicator lamps:


Ready for operation (green)
Enable (yellow)
Potentiometers
Sw+

Step-change height for positive direction

Sw Step-change height for negative direction


t<

Ramp time for rising command values

t>

Ramp time for falling command values

Frequency setting, 240 Hz preset,


adjustable from 150 Hz 400 Hz

40

Operating mode selector switch: Without function


Measuring sockets:
t<

Ramp time up

t>

Ramp time down

Actual current value

Command value

wR

Command value after ramp


Measurement zero

243
RE 30228-200/07.05

VT-MSPA2-200

Hydraulics Bosch Rexroth AG

7/8

Important notes / adjustment information


Risk of explosion in the case of incorrect installation !
To achieve the prescribed level of safety when operating one of the listed valves in a potentially explosive atmosphere,
this amplifier module must be connected to safety module VT-MUXA2.
In this context, read operating instructions RE 30290-B0 for the safety module!
This amplifier module and safety module VT-MUXA may only be installed outside potentially explosive atmospheres!
The amplifier module is not subject to Directive 94/9/EC (ATEX Directive) !

Further notes:
The amplifier module may only be wired when disconnected from the power supply!
Do not lay signal cables near power cables and lines!
Do not use free-wheeling diodes in solenoid cables!
The distance to aerial lines, radio sources and radar equipment must be at least 1 m!
Always shield command value cables and connect the shield to the protective earth (PE) on the module side!
Also shield solenoid cables!
For solenoid cables up to 50 m length, use cable type LiYCY 1.5 mm2!
In the case of greater lengths, please consult us!
For applications and use in conjunction with safety module VT-MUXA, please observe the installation instructions in the
associated operating instructions RE 30290-B0.
Use relays with gold-plated contacts for passing on command values (small voltages, small currents)!
Measurements on the module may only be taken with instruments with Ri > 100 k.
For adjusting the potentiometers, use a screwdriver with a blade width of 4 mm!
In the case of strongly fluctuating operating voltages, it may be required to install an external smoothing capacitor having a
capacitance of at least 2200 F.
Recommendation:
Capacitor module VT 11073 (see RE 29750), sufficient for up to 3 amplifier modules
In conjunction with safety module VT-MUXA, the operating voltage must be directed via a capacitor module.
The solenoid current connections to safety module VT-MUXA must be routed via ferrite sleeves. These ferrite sleeves are included in the scope of supply of safety module VT-MUXA.
The clock frequency is factory-set to 240 Hz. Turning of potentiometer f results in a change in the valve hysteresis and can
cause annoying noise.

Adjustment information
Preconditions: The system-specific connections must have been made.
Signal

Adjustment

Ramp time

Adjust ramp time according to formula or table (see functional description of ramp generator) and
check at measuring sockets "t >" and "t <"

Step-change height Apply enable signal


Apply an external command value of +0.3 V and adjust the measured signal at "wR" to +0.3 V
Adjust the required positive step-change height using potentiometer "Sw+"
Apply an external command value of 0.3 V and adjust the measured signal at "wR" to 0.3 V
Adjust the required positive step-change height using potentiometer "Sw"
Note:
With external command value feedforward, the latter must result in at least +0.3 V / 0.3 V at measuring socket wR.
Clock frequency

Factory setting: f = 240 Hz


Note:
The frequency can be newly set with the help of a digital multimeter that is capable of measuring frequencies. Measurement at connecting terminals 7 or 9 against 2 (ground).

01

244
8/8

Bosch Rexroth AG

Hydraulics

VT-MSPA2-200

RE 30228-200/07.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

245

Electrical amplifier module for


controlling proportional throttle valves
with electrical position feedback

RE 29756/09.05
Replaces: 02.03

1/6

Type VT 11037

Series 1X

H5272

Table of contents
Contents

Features
Page

Features

Ordering code

Function

Block circuit diagram / pin assignment VT 11037

Technical data

Terminal connection

Characteristics in the event of a fault

Engineering / maintenance notes / supplementary information 6


Unit dimensions

VT 11037 amplifier modules are used for controlling pilot operated proportional throttle valves with electrical position feedback
(type FES 25 C).
Differential input
Adjustable ramp generator (max. ramp time 5 s)
Clocked output stage
Controller for valve spool position
Reverse polarity protection for voltage supply
Oscillator and demodulator for inductive position measurement
Controller enable
LED lamps: power internal supply voltage (green)
H1 multi-function indicator (orange)

246

Ordering code

VT 11037

1X

*
Further details in clear text

Amplifier module
for proportional throttle valves type FES 25 C

1X =

1)

Series 11 to 19 1)
(11 to 19: unchanged technical data and
pin assignment)

Compatible with components of series 10 to 14, if


terminal 11 of these components was not connected
to ground (0 V) (see engineering notes on page 4).

Function
This amplifier module is to be snapped onto carrier rails that
are usually installed in control cabinets. The electrical connection is made via a terminal strip.

the command value are corrected. The controller and the output stage are enabled by applying a positive voltage
(U E > 8.5 V) to terminal 3.

The amplifier module includes the electronics for controlling a


proportional solenoid. The amplifier module controls the
solenoid in dependence upon a positive voltage signal
applied to the command value input. The actual value (position
of the magnet armature) is sensed by an inductive position
measuring system and compared with the command value that
is provided externally. Any differences between the actual and

The following parameters can be adjusted from outside using a


trimming potentiometer each:
Ramp time up to approx. 5 s
Command value attenuation within the range from 0 % to
100 %
Zero point of the position transducer

247

Block circuit diagram / pin assignment VT 11037 (from series 11)


Only with special version with current input 4 to 20 mA (on enquiry)

Enable +UE

3
H1

Differential input
Reference potential
+Ucomm

4
5

PI

u
i

u(i)

8
4

Gw

01

2 1

PI
2
t

Operating voltage

Gx
+ UM
M0
UM

+ DC
DC

power

Zx

12

10

11

(1) Ramp generator

(6) Power supply unit

(2) Spool position controller

(7) Monitoring

1 IActual value 0 to 5 V

(8) Differential amplifier

2 Comm. value 0 to +5 V

(3) Current regulator

(9) Proportional valve

3 Measuring zero

(10) Position transducer

Gw Comm. value
attenuation

4 Messnull
Measuring zero

Gx Actual value adjustment

(4) Output stage


(5) Oscillator/demodulator

Measurements

H1 Multi-function indicator
Zx Pos. transducer
zero point

t Ramp time

248
4/6

Bosch Rexroth AG

Hydraulics

VT 11037

RE 29756/09.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO +24 VDC +40 % 10 %

Operating range
Upper limit value

uO(t)max +39 V

Lower limit value

uO(t)min +21 V

Max. current consumption

I 1.5 A

Fuse

I 2.5 A, slow-blowing, self-activating after tripping

Inputs
Differential input (command value input)

Ui 0 to +10 V, Ri = 50 k (standard) 1)

Enable
active

UE 8.5 V < U E < 40 V

inactive

UE < 6.5 V

Demodulator input (position measuring system)


Ramp time (adjustment range)

Ri > 50 k
t 10 ms to 5 s

Outputs
Output stage
solenoid current/resistance
clock-pulse frequency

Imax 1.3 A, R20 = 12,7


f Freely clock-pulsing up to ca. 1.5 kHz

Driver for inductive position transducer


oscillator frequency
max. load-carrying capacity
voltage amplitude (USS)
max. stroke of position transducer

f 5.8 kHz 10 %
I 30 mA
Ua 5 V per output
s 5.0 mm

Measuring sockets
command value w

Uw 0 to +5 V

actual position value x

Ux 0 to 5 V

Type of connection

12-pin terminal strip

Housing dimensions (W x H x D)

40 x 79 x 85.5 mm

Permissible operating temperature range

t 0 to 50 C to DIN IEC 68-2 T1, T2, T14 and T30:1979 2)

Storage temperature range

t 25 to +85 C to DIN IEC 68-2 T1 and T2:1979 2)

Immunity to interference

Class 3 to prEN 50082 T2:1992 2)

Mechanical stress

To DIN IEC 68-2 T6, T24 and T27:1979 2)

Weight
1)

Current input on enquiry

2)

Further details on enquiry

m 0.14 kg

249
RE 29756/09.05

Hydraulics Bosch Rexroth AG

VT 11037

5/6

Terminal connection

Operating voltage

+UO

0V

UE

n.c.

Reference
potential

10

n.c.

+Ucomm

11

Enable

Differential input

Pos. transducer connection

12

Solenoid connection

Pos. transducer connection

01

Connecting cable (recommendation):


Position transducer

3-wire cable,
single shield, cross-section
max. 1.5 mm2

Solenoid connection

2- or 4-wire cable,
single shield, cross-section
max. 1.5 mm2

Differential input

2-wire cable,
single shield

Characteristics in the event of a fault


Fault

Missing
enable (UE < 6,5 V)

Cable break of
position transducer

Cable break of
position transducer 1)

Behaviour of
electronics

E, R, A

E, R, A

S, A

1)

Meaning of abbreviations:

Only with special version with current


input 4 to 20 mA (on enquiry)

E = Output stage is switched off (solenoids are de-energized!)


R = Controller is switched off
S = Command value is set to 0 %
A = Multi-function indicator is alight

250
6/6

Bosch Rexroth AG

Hydraulics

VT 11037

RE 29756/09.05

Engineering / maintenance notes / supplementary information


The amplifier module may only be wired when disconnected from the power supply!
Do not connect the ground cable of the inductive position transducer to the ground!
Do not connect terminal 11 to ground, earth or shield, otherwise malfunction may occur!
(This was also not permitted for components of series 10, but did not result in malfunction.)
Always shield command value cables and cables of the inductive position transducer separately, leave shield open on the valve side,
Connect shield to 0V operating voltage (terminal 2) on the module side only to prevent interference!
Do not lay cables near power cables!
Do not use free-wheeling diodes in solenoid cables!
The distance to aerial lines, radio sources and radar equipment must be at least 1 m!
Due to the charging current of the integrated smoothing capacitor, the back-up fuses must be of the slow-burning type!
Caution

When the differential input is used (command value as voltage signals), both inputs must always be
activated or deactivated simultaneously!

Actual value adjustment (potentiometer Gx) is factory-calibrated and must not be adjusted!

Unit dimensions (dimensions in mm)


top hat rail THs 35/7,5
to EN 60715

H1

Multifunction indicator (see page 2)

power

Internal voltage supply

Gw

Command value attenuation

Ramp time

Gx

Actual value adjustment

Zx

Position transducer zero point

Measuring socket 1

Actual value 0 to 5 V

Measuring socket 2

Command value 0 to +5 V

1 2 3 4 5 6

Measuring socket 3

Measuring zero

Measuring socket 4

Measuring zero

7 8 9 10 11 12
REXROTH

VT 11037-1X
Gw
79

power t
H1

Gx
Zx
1
3

85,5

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

40

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

251

RE 29865/06.05
Replaces: 02.03

Analogue amplifier modules

1/4

Types VT 11131 and VT 11132

Series 1X

H3786

Table of contents

Features

Features

Suitable for controlling proportional pressure control valves


without electrical position feedback

Ordering code

Differential input

Functional description

One clocked output stage

Block circuit diagram / pin assignment

Function generator

Technical data

Output characteristic curve

Ramp generator with adjustable ramp time


(up and down ramp can be adjusted separately)

Terminal assignment

Unit dimensions

Contents

Page

Engineering / maintenance notes / supplementary information 4

Information on available spare parts:


www.boschrexroth.com/spc

Adjustable current regulator


Reverse voltage protection for voltage supply
Indication of solenoid energisation by LED
(brightness of LED proportional to solenoid current)

252
2/4

Bosch Rexroth AG

Hydraulics

VT 11131; VT 11132

RE 29865/06.05

Ordering code

VT 1113_

1X

*
Further details in clear text

Amplifier modules for controlling proportional pressure control valves:


Types (Z)DBE 6, DBE(M) 10, DBE(M) 20 und ZDRE 10
=1
Type (Z)DRE 6
=2
Series 10 to 19
(10 to 19: unchanged technical data and pin allocation)

= 1X

Functional description
These amplifier modules are suitable for controlling a
proportional solenoid. The amplifier modules are to be snapped
onto carrier rails according to EN 60715. The electrical
connections are made by means of screw terminals. The
modules are operated using 24V DC.
The solenoid current (actual value) is measured and compared
with the externally provided command value. Any differences
occurring between actual and command value, caused e.g. by
changes in the solenoid temperature or operating voltage, are
balanced.

The activation of solenoid control is indicated by LED H3, the


brightness of which is proportional to the solenoid current.
The following values can be adjusted from outside by means of
assigned trimming potentiometers:
Ramp time, separately for up and down ramp
(by means of R11, R12 tmax approx. 5 s)
Gradient of the output characteristic curve (by means of R1, R2)

Block circuit diagram / pin assignment


6
+UB
R11
Differential input:
Ucomm: 0 to +10 V
Reference potential/GND

R2

6
3

R12

u
2

R1

H3

+UB

+ UB
Operating
voltage
0V

DC

DC

Power supply unit

Clock-pulse generator

Differential amplifier

Output stage

Ramp generator

Switching stage

Function generator

Proportional solenoid

Current regulator

253
RE 29865/06.05

Hydraulics Bosch Rexroth AG

VT 11131; VT 11132

3/4

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC +40 % 10 %

Operating range:
Upper limit value

uB(t)max 35 V

Lower limit value

uB(t)min 21 V

Power consumption

PS max 28 VA

Current consumption

Imax 1.3 A

Fuse

Electronic short-circuit protection of the solenoid

Inputs:
Command value (differential input)

Ucomm 0 to +10 V; Ri approx. 10 k

Adjustment ranges:
Output current

I I10% to Imax

Ramp time

t approx. 50 ms to approx. 5 s

01

Outputs:
Solenoid current / resistance
with VT 11131

Imax 1.6 A; R(20) = 5.4

with VT 11132

Imax 1.6 A; R(20) = 5.4

Clock-pulse frequency of output stage


with VT 11131

f 300 Hz 15 %

with VT 11132

f 360 Hz 15 %

Type of connection

6 screw terminals

Type of mounting

Carrier rail TH 35/7.5 to EN 60715

Type of protection

IP 20 to DIN 40050

Dimensions (W x H x D)

25 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +85 C

Weight

m 0.13 kg

Note:
For details regarding environment simulation tests in the field of climate,
see RE 30309-U (declaration on environmental compat-ibility).

Output characteristic curve

Output current in A

VT 11131 and VT 11132

Imax 1,6
1,5

1,0

I10% 0,5

0 10 20

40

60

80

Command value in %

100

254
4/4

Bosch Rexroth AG

Hydraulics

VT 11131; VT 11132

RE 29865/06.05

Terminal assignment

Operating
voltage

+UO

0V

Reference
potential

Proportional
solenoid

+Ucomm

Terminals 3 and 6: Differential input

Unit dimensions (Dimensions in mm)


Carrier rail TH 35/7,5
to EN 60715
4 5 6

79

REXROTH
VT 11131

Adjustment/indication element

set to

Potentiometers:
R1

Imax

1,6 A

R11
R12

R2

I10 %

0,5 A

R11

Up ramp

min

R1
H3
R2

R12

Down ramp

min

LED Lamp:
H3

Solenoid current

1 2 3
85,5

25

Engineering / maintenance notes / supplementary information


The amplifier module may only be wired when disconnected from the power supply!
The distance to radio equipment must be sufficiently large (>> 1 m)!
Command value cables must always be shielded and not laid near power cables;
shield solenoid cables!
Do not use free-wheeling diodes in the solenoid cables!
In the case of heavy fluctuations in the operating voltage, it may become necessary to install an external smoothing capacitor
having a capacitance of at least 2200 F.
Recommendation: Capacitor module type VT 11073 (se RE 29750); sufficient for up to 3 amplifier modules!

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

255

RE 30226/06.05
Replaces: 02.03

Analogue amplifier modules

1/6

Types VT 11004, VT 11015 and VT 11026

Series 1X

F87160_d

Table of contents

Features

Features

Suitable for controlling proportional pressure reducing valves


without electrical position feedback

Ordering code

Differential input

Functional description

2 clocked output stages

Block circuit diagram / pin assignment

Step function generator

Technical data

Output characteristic curve

2 signal switching outputs for controlling the VT 11003-1X


switching amplifier module

Terminal assignment

Unit dimensions

Contents

Page

Engineering / maintenance notes / supplementary information 6

Information on available spare parts:


www.boschrexroth.com/spc

Reverse polarity protection for voltage supply


Short-circuit protection through overcurrent detection and
shutdown
Direction indication by LED
(brightness of LED proportional to solenoid current)

256
2/6

Bosch Rexroth AG

Hydraulics

VT 11004; VT 11015; VT 11026

RE 30226/06.05

Ordering code

VT 110_ _

1X

Amplifier module for controlling proportional


pressure reducing valves type DRE 4 K-3X/.G24-10:
With output characteristic curve 1
= 04
With output characteristic curve 2
= 15
With output characteristic curve 3
= 26
Series 10 to 19
(10 to 19: unchanged technical data and pin assignment)

*
Further details in clear text

= 1X

Functional description
The amplifier modules are to be snapped onto carrier rails
according to EN 60715. The electrical connection is made
using screw terminals. The modules are operated with
24 V DC voltage.

In addition, the module outputs a direction-dependent voltage


signal (solenoid A; solenoid B) as soon as the solenoid
current jumps to the value of I10%.

The amplifier modules include the electronics for controlling


two proportional solenoids. Depending on the command value
polarity, solenoid A or solenoid B is activated. The solenoid current is measured and compared with the command value
provided externally. Any differences between the actual value
and the command value, caused, e.g. by changes in the
solenoid temperature or the operating voltage, are corrected.

The following parameters can be adjusted externally using a


trimming potentiometer:
Current I10% and I90%; together for A and B

257
RE 30226/06.05

3/6

Hydraulics Bosch Rexroth AG

VT 11004; VT 11015; VT 11026

Block circuit diagram / pin assignment

12

R1
Differential input (Ucomm): 5
0 to +10 V A
0 to 10 V B 4

Solenoid
A

Reference potential/GND

R2

9
7
Solenoid
B

10
B
11

Signal
switching
output A

Signal
switching
output B

+ UB 1
Operating
voltage

+ UM
M0
UM

DC
0V

DC

Power supply unit

Summator

R1

Current intensity at 10% step change

Differential amplifier

Controller

R2

Current intensity at 90% step change

Absolute value generator

Clock-pulse generator

Enable output stage A

Output stage

Enable output stage B

10

Overcurrent detection and shutdown

01

258
4/6

Bosch Rexroth AG

Hydraulics

VT 11004; VT 11015; VT 11026

RE 30226/06.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC +40 % 10 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 21 V

Power consumption

PS max 25 VA

Current consumption

Imax ca. 1.2 A

Fuse

IS Electronic short-circuit monitoring of the solenoid

Inputs:
Command value (differential input)

Ucomm 0 to 10 V; Ri ca. 20 k

Adjustment range:
Output current

I I10% to Imax

Outputs:
Output stages
solenoid current / resistance VT11004; VT 11015
VT11026
clock-pulse frequency

Imax 1000 mA; R(20) = 12


Imax 800 mA; R(20) = 12

VT11004; VT 11015

f 230 Hz 15 %

VT11026

f 170 to 200 Hz 15 %

Signal switching output

U 0 to +6 V; Ri ca. 10 k

Type of connection

12 screw terminals

Type of mounting

Carrier rail TH 357.5 to EN 60715

Type of protection

IP 20 to EN 60529

Dimensions (W x H x D)

40 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +70 C

Weight

m 0.16 kg

259
RE 30226/06.05

Hydraulics Bosch Rexroth AG

VT 11004; VT 11015; VT 11026

5/6

Output characteristic curve


Characteristic curve 1 (VT 11004)

Output current in mA

Imax 1000

I90% 660
500
I10% 330

10 9

1 0 +1

+5

+ 9 +10

Command value voltage in V

01

Characteristic curve 2 (VT 11015)

Output current in mA

Imax 1000

500
I10% 330

10

1 0 +1

+5

+10

Command value voltage in V


Characteristic curve 3 (VT 11026)

Output current in mA

1000
Imax 800
I90% 680
500
I10% 280

10 9

1 0 +1

+5

Command value voltage in V


I10% and I90% can be adjsted from outside using
trimming potentiometers:
I10% min ~ 10 mA

I10% max ~ 500 mA

I90% min = I10% + 50 mA

I90% max = Imax

+ 9 +10

260
6/6

Bosch Rexroth AG

Hydraulics

VT 11004; VT 11015; VT 11026

RE 30226/06.05

Terminal assignment

Operating
voltage

Differential
input

+UO

Solenoid B

0V

Solenoid A

n.c.

n.c.

Reference
potential

10

n.c.

Ucomm

11

Signal switching output solenoid B

n.c.

12

Signal switching output solenoid A

Unit dimensions (dimensions in mm)


Carrier rail TH 357.5
to EN 60715
7 8 9 10 11 12
REXROTH
VT 11015

79

R1

Potentiometer:

Factory setting:
VT 11004

VT 11015

VT 11026

R1 I10 %

330 mA

330 mA

280 mA

R2 I90%

660 mA

Imax

680 mA

LED lamps:

B
R2

A Controlling of solenoid A
B Controlling of solenoid B

1 2 3 4 5 6
85,5

40

Engineering / maintenance notes / supplementary information


The amplifier module may only be wired when disconnected from the power supply!
Ensure a sufficient distance to radio equipment (>> 1 m)!
Shield command value cables; do not lay them near power cables;
shield solenoid cable!
Do not use free-wheeling diodes in solenoid cables!
Reset of the overcurrent shutdown by providing a zero command value!
In the case of heavy fluctuations in the operating voltage it may be required to install an external smoothing capacitor having a
capacitance of at least 2200 F
Recommendation: VT 11073 capacitor module (see RE 29750); sufficient for up to 3 amplifier modules

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

261

Electrical amplifier modules for


controlling proportional and on/off
valves

RE 29870/06.05
Replaces: 02.03

1/8

Type VT 11550 to VT 11554

Series 2X

H2946_d

Table of contents
Contents

Features
Page

Features

Ordering code

Function

Technical data

Block circuit diagram / pin assignment VT 11550 to VT 11553 4


Block circuit diagram / pin assignment VT 11554

Characteristic curves of proportional outputs

Terminal assignment VT 11550 to VT 11553

Terminal assignment VT 11554

Unit dimensions

Engineering / maintenance notes / supplementary information 8


Notes on fault diagnosis

Information on available spare parts:


www.boschrexroth.com/spc

Amplifier modules VT 11550 to VT 11554 are used for controlling two proportional solenoids or two switching solenoids.
Depending on the version, up to two clocked output stages for
proportional solenoids and two switching outputs
Differential amplifier input 10 V
Enable input
Step function generator
Adjustable time ramp (using trimming potentiometer)
External time ramp shutdown
Restricted short-circuit protection
Potentiometer for setting I10% and I90% or Imax
Output for fault messages and indication of faults by LED
Further LED lamps:
Active proportional solenoid and switching outputs
Internal supply voltage

262
2/8

Bosch Rexroth AG

Hydraulics

VT 11550 to VT 11554

RE 29870/06.05

Ordering code

VT 115_ _
Proportional
outputs

Switching
outputs

yes

yes

= 50

yes

yes

= 51

yes

no

= 52

yes

no

= 53

yes

no

= 54 1)

1)

Jump at
Jump at
Ucomm = 10 % Ucomm = 90 %

2X

*
Further details in clear text

2X =

Series 20 to 29
(20 to 29: unchanged technical data
and pin assignment)

Application example: Pump adjustment via proportional solenoid

Function
The electrical amplifier modules are to be snapped onto carrier
rails that are usually installed in control cabinets. The electrical
connection is made via a terminal strip.
The outputs of the amplifiers for proportional solenoids Ax and
Bx and, if required, switching outputs As and Bs are activated
by applying a minimum command value voltage of approx.
10 % to the differential amplifier input. A positive command
value voltage controls outputs A, a negative command value
voltage controls outputs B. In the case of amplifier type VT
11554 the proportional solenoid can be controlled in
accordance with two different characteristic curves, depending
on the polarity of the command value voltage.
With a command value voltage of approx. 10 % referred to a
10 V input voltage at the differential amplifier, the output current increases step-like. The height of the 10 % step-change
can be adjusted separately for proportional outputs Ax and Bx
from outside using a potentiometer. As the command value
voltage increases, the solenoid current of the proportional
outputs rises linearly.
With amplifier types VT 11550 and VT 11551 an additional
current step-change takes place at a command value voltage of
about 90 %.

The maximum current or the 90 % step-change can be adjusted separately for outputs Ax and Bx from outside using trimming potentiometers. This has also an influence on the gradient
of the output characteristic curve.
LEDs signal the individual activation for each proportional and
switching output, with the brightness being roughly proportional to the solenoid current intensity of Ax and Bx.
The output stages can be enabled or disabled via the enable
input.
A time ramp function, which can be externally influenced via a
trimming potentiometer, is implemented in the amplifiers. The
adjustment range of the ramp time ranges from approx. 80 ms
to approx. 1 s. The time setting acts equally on the up and the
down ramp and on both proportional solenoids. The internal
time ramp function can be bridged via input ramp off.
The amplifiers are provided with an output for fault messages,
which can be used in conjunction with the LED lamps for fault
diagnosis (see page 5). The activation of the fault output is at
the same time signalled by the fault LED.

263
RE 29870/06.05

Hydraulics Bosch Rexroth AG

VT 11550 to VT 11554

3/8

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC

Upper limit value

uO(t)max 35 V 1)

Lower limit value

uO(t)min 21 V 1)
1)

UB

Momentary value
+45 %
10 %

35 V
30 V

40 C
Note:

70 C

Each individual module must be provided with an external


2200 F smoothing capacitor!
(Capacitor module VT 11073, see RE 29750)

Valve type:
Proportional valve

DRE 4 K (solenoid GP 3512 ; 1 A)

On/off valve

3 WE 4 (not with VT 11551 and VT 11553)


(solenoid GU 35 26 V; 26 W)

Clock-pulse frequency (proportional output)


Max. power consumption

f 230 Hz 15 %
Pmax 25 VA

Max. output current


Proportional output

Imax 1.0 A

Switching output

Imax 1.2 A

Enable voltage
Command value voltage range
Max. common-mode control

UE > 18 V
Ucomm 0 bis 10 V
Umax 3 V

Input capacitance of the operating


voltage connections

CI 0.2 F

Input resistance of the differential


amplifier (command value input)

RI > 5 k

Permissible ambient temperature range


Storage temperature range
Weight

t 30 bis +70 C
t 30 bis +75 C
m ca. 0.16 kg

01

Operating voltage
(amplifier module) 0 V

7
8
9

Trigger for 10 % step-change

Function generator

Summator

Output stage

I10%B

I10%A

I2B

I2A

M0
UM

+ UM

power

time

Imax

Ramp generator

DC
DC

Power supply unit

Fault detection

Trigger for ramp enable

Differential amplifier

1)

+U

10

Evaluation
solenoid current

Fault message

Switching
solenoid Bs1)

Switching
solenoid As1)

Proportional
solenoid Ax

Proportional
solenoid Bx

Enable

Not with VT 11551 and VT 11553!

fault

Bs1)

As1)

Ax

Bx

11

VT 11550 to VT 11554

+U

Hydraulics

+ UB

0 to 10 V > B

0 to + 10 V > A

Reference potential

Differential input:

12

Bosch Rexroth AG

Time ramp off

Supply voltage
(solenoid) + U

4/8

264
RE 29870/06.05

Block circuit diagram / pin assignment VT 11550 to VT 11553

+U

7
8
9

Trigger for 10 % step-change

Function generator

Summator

Output stage

I10%A2

I10%A1

ImaxA2

ImaxA1

M0
UM

+ UM

power

time

Imax

DC
DC

Ramp generator

+U

12

Power supply unit

Fault detection

Trigger for ramp enable

Differential amplifier

+U

fault

As

Ax

10

Evaluation
solenoid current

11

Fault message

Switching
solenoid As

Proportional
solenoid Ax

Enable

VT 11550 to VT 11554

B
Operating voltage
(amplifier module) 0 V

0 to 10 V > A2

0 to + 10 V > A1

Reference potential

Differential input:

Time ramp off

Supply voltage
(solenoids) + U

RE 29870/06.05

265
Hydraulics Bosch Rexroth AG
5/8

Block circuit diagram / pin assignment VT 11554

01

266
6/8

Bosch Rexroth AG

Hydraulics

VT 11550 to VT 11554

RE 29870/06.05

Characteristic curves of proportional outputs


Type VT 11550 and VT 11551
Isolenoid
max. 1 A

I100%
I90%

Ax

Bx

I10%

10 V ~ 9,2 V

~ 9,2 V +10 V

~ 0,8 V ~ 0,8 V

Ucomm

Type VT 11552 and VT 11553


Isolenoid
max. 1 A

I100%

Bx

Ax

I10%

10 V

+10 V

~ 0,8 V ~ 0,8 V

Ucomm

Type VT 11554
Isolenoid
max. 1 A

I100%

Ax(A2)

Ax(A1)

I10%

10 V

+10 V

~ 0,8 V ~ 0,8 V

Ucomm

Terminal assignment VT 11550 to VT 11553

+U

Bx

Output, proportional solenoid B

0V

Ax

Output, proportional solenoid A

Bs

As

Signal switching output A 1)

Reference potential

GND

10

Fault message (> 18 V active / max. 40 mA)

Ucomm: 0 to +10V A
0 to 10V B

Ucomm

11

UE

+ UO

12

Supply voltage
(solenoids)
Signal switching output B 1)
Differential input:

Operating voltage
(amplifier module)

1)

Enable input (+24 V active)


Time ramp off (+24 V active)

Not with VT 11551 and VT 11553 (terminal not assigned)

267
RE 29870/06.05

7/8

Hydraulics Bosch Rexroth AG

VT 11550 to VT 11554

Terminal assignment VT 11554

+U

n. c.

0V

Ax

Output, proportional solenoid (A1, A2) 2)

n. c.

As

Signal switching output

Reference potential

GND

10

Fault message (> 18 V active / max. 40 mA)

Ucomm: 0 to +10V A1
0 to 10V A2

Ucomm

11

UE

+ UO

12

Supply voltage
(solenoids)

Differential input:

Operating voltage
(amplifier module)

2)

Enable input (+24 V active)


Time ramp off (+24 V active)

01

See characteristic curve VT 11554

Unit dimensions (dimensions in mm)


Type VT 11550 to VT 11553

Carrier rail NS 35/7,5


to DIN 50022

Ax:

Proportional output Ax active

As:

Switching output As active (not connected on


VT 11551 and VT 11553)

7 8 9 10 11 12

Bx:

Proportional output Bx active

power

Bs:

Switching output Bs active (not connected on


VT 11551 and VT 11553)

time

Fault message

Ax

time:

Ramp time adjustment (ca. 80 ms to 1 s)

As

I2:

Max. current setting for proportional solenoid Ax

10 %:

Adjustement of 10 % step-change for


proportional solenoid Ax

10 %:

10%

Bs

fault:

B I :
2

B I2

Bx

79

power: Internal supply voltage

fault

A I2
10%

1 2 3 4 5 6
85,5

40

Max. current setting for proportional solenoid Bx


Adjustement of 10 % step-change for
proportional solenoid Bx

Type VT 11554

Carrier rail NS 35/7,5


to DIN 50022

Ax:

Proportional output active

As:

Switching output active

7 8 9 10 11 12

power: Internal supply voltage

A1
A2

Fault message

time:

Ramp time adjustment (ca. 80 ms to 1 s)

Imax:

Max. current setting for characteristic curve A1

10 %:

Adjustment of 10% step-change for char. curve A1

Imax:

Max. current setting for characteristic curve A2

10 %:

Adjustment of 10% step-change for char. curve A2

A2max
10%

79

fault:

fault

power

time
Ax Imax
A1
As 10%
1 2 3 4 5 6
85,5

40

268
8/8

Bosch Rexroth AG

Hydraulics

VT 11550 to VT 11554

RE 29870/06.05

Engineering / maintenance notes / supplementary information


The amplifier module may only be wired when disconnected from the power supply!
Ensure a sufficient distance to radio equipment (>> 1m)!
Do not lay cables near power cables!
Do not use free-wheeling diodes in solenoid cables! When solenoid cables are interrupted (e.g. by a relay)
corresponding protective circuits are required.
Be careful with time ramp operation! When the electronics are switched off, the time ramp cannot be executed.
In the case of solenoid output overloading, the relevant output is switched off. If overloading persists at a command
value voltage of 10 V, the output stage is switched on and off in 5 ms cycles. This impermissible situation
can be recognised at the fault message output and must be remedied as quickly as possible!
If safety aspects advise against the permanent application of the operating voltage to terminal 6, the supply cable may
be protected by installing a back-up fuse of 0.063 A (F).
When the operating voltage is applied simultaneously to terminal 1 and terminal 6, this may result in a brief response of the
power output stages. This transitional state can be avoided by applying the operating voltage to terminal 1 with a certain delay.
The failure of the amplifier module can result in undefined characteristics!
If electromagnetic interference must be expected, suitable measures must be taken to ensure the operability
(depending on application, e.g. shield, filtration)!

Notes on fault diagnosis


Overloading of an output:
Voltage to fault output (terminal 10) > 18 V
fault LED lights up
Cable break in the cables of a proportional solenoid:
Activation LED of the proportional output concerned is permanently alight
at full brightness, even if the command value voltage at terminal 5 is reduced.

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

269

RE 29866/06.05
Replaces: 02.03

Analog Amplifier Module

1/4

Type VT 11724

Series 1X

H3783_d

Table of contents

Features

Features

Suitable for controlling proportional pressure reducing valves


without electrical position feedback

Ordering code

Differential input

Functional description

One clocked output stage

Block circuit diagram / Pin allocation

Function generator

Technical data

Output characteristic curve

Ramp generator with adjustable ramp time


(up and down ramp can be adjusted separately)

Terminal assignment

Unit dimensions

Contents

Page

Engineering notes / Maintenance instructions / Supplementary


information
4

Information on available spare parts:


www.boschrexroth.com/spc

Adjustable current regulator


Reverse voltage protection for voltage supply
Power supply indication by LED
(brightness of LED proportional to solenoid current)

270
2/4

Bosch Rexroth AG

Hydraulics

VT 11724

RE 29866/06.05

Ordering code
VT 11724

1X

*
Further details in plain text

Amplifier module for controlling proportional pressure reducing valves


types 3DRE(M) 10 (up to series 4X) and 3DRE(M) 16 (up to series 5X)
as well as DRE(M) 10 and DRE(M) 20
Series 10 to 19
(10 to 19: unchanged technical data and pin allocation)

= 1X

Functional description
The activation of solenoid control is indicated by LED H3, the
brightness of which is proportional to the solenoid current.

These amplifier modules are suitable for controlling a proportional solenoid. They are to be snapped onto carrier rails
according to EN 60715. The electrical connections are made
by means of screw terminals. The modules are operated using
24 V DC.

The following values can be adjusted from outside by means of


assigned trimming potentiometers:
Ramp time, separately for up and down ramp
(by means of R11, R12 tmax approx. 5 s)

The solenoid current (actual value) is measured and compared


with the externally provided command value. Any occurring
differences between actual and command value, caused e.g.
by changes in the solenoid temperature or operating voltage,
are balanced.

Slope of the output characteristic curve (by means of R1, R2)

Block circuit diagram / Pin allocation


6
+UB
R11
Differential input 6
Ucomm: 0 to +10 V
3
Reference potential/GND

R12

R2

7
u

u
2

R1

H3

+UB

+ UB

DC

DC

Operating
voltage
0V

Power pack

Clock-pulse generator

Differential amplifier

Output stage

Ramp generator

Switching stage

Function generator

Proportional solenoid

Current regulator

271
RE 29866/06.05

Hydraulics Bosch Rexroth AG

VT 11724

3/4

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UB 24 V DC +40 % 10 %

Operating range:
Upper limit value

uB(t)max 35 V

Lower limit value

uB(t)min 21 V

Power consumption

PS max 22 VA

Current consumption

Imax 0.85 A

Fuse

IS Electronic short-circuit protection of the solenoid

Inputs:
Ucomm 0 to +10 V; Ri approx. 10 k

Command value (differential input)


Adjustment ranges:
Output current

I I10% to Imax

Ramp time

t approx. 50 ms to approx. 5 s

Outputs:
Imax 800 mA; R(20) = 19.5

Solenoid current / resistance


Clock-pulse frequency of output stage

f 200 Hz 10 %

Type of connection

6 screw terminals

Type of mounting

Carrier rail TH 35/7.5 to EN 60715

Type of protection

IP 20 to DIN 40050

Dimensions (W x H x D)

25 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +85 C

Weight

m 0.13 kg

Note:
For details regarding environment simulation tests in the field of climate,
see RE 30309-U (declaration on environmental compatibility).

Output characteristic curve

Output current in mA

Imax 800

500

I10% 220

0 10 20

40

60

80

Command value in %

100

01

272
4/4

Bosch Rexroth AG

Hydraulics

VT 11724

RE 29866/06.05

Terminal assignment

Operating
voltage

+UB

0V

Reference
potential

Proportional
solenoid

+Ucomm

Terminals 3 and 6: Differential inputs

Unit dimensions (Dimensions in mm)


Carrier rail TH 35/7,5
to EN 60715
4 5 6

79

REXROTH
VT 11724

Adjustment/indication element set to


Potentiometers:
R1

Imax

800 mA

R11
R12

R2

I10 %

220 mA

R11

Up ramp

min

R1
H3
R2

R12

Down ramp

min

LED lamp:
H3

Solenoid current

1 2 3
85,5

25

Engineering notes / Maintenance instructions / Supplementary information


The amplifier module may only be wired when disconnected from the power supply!
The distance to radio equipment must be sufficiently large (>> 1 m)!
Command value cables must always be shielded and not laid near power cables;
shield solenoid cables!
Do not use free-wheeling diodes in the solenoid cables!
In the case of heavy fluctuations in the operating voltage, it may become necessary to install an external smoothing capacitor
having a capacitance of at least 2200 F.
Recommendation: Capacitor module type VT 11073 (see RE 29750); sufficient for up to 3 amplifier modules

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

273

RE 29 763/12.02
Replaces: 11.95

H/A 5316/95

Electrical amplifier module


for the flow control of a variable
displacement axial piston pump
with electrical position feedback
Type VT 11 019, series 1X

01
VT 11 019 (from series 11)

Overview of contents
Contents
Features
Ordering details
Function
Technical data
Characteristics in the case of a fault
Block circuit diagram
Terminal allocation
Unit dimensions
Engineering / maintenance guidelines

Features
Page
1
1
2
2
3
3
4
4
5

The VT 11 019 amplifier module is used for controlling the flow of a


variable displacement axial piston pump with electrical position
feedback and FE control (type A10VSOFE).

Differential input
Adjustable ramp generator (max. rampen time 5 s)
Pulsed output stage
Controller for the valve spool position
Supply voltage polarity protection
Oscillator and demodulator for the inductive position
measurements
Controller enable
LED displays: "power" Internal supply voltage (green)
"H1" Multi-function display (orange)

Ordering details
VT 11 019

1X / *

Amplifier module for the flow control of a variable


displacement axial piston pump type A10VSOFE

1X =

1)

Further details in clear text


Series 11 to 19 1)
(11 to 19: unchanged technical data
and connection allocation)

Compatible with series 10 units, when terminal 11


has not been connected to ground (0 V) in these units
(see engineering guidelines on page 4).

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

VT 11 019

1/6

RE 29 763/12.02

274

Function
The amplifier module is clipped onto carrier rails such as those
commonly used in electric control cabinets. The electric connections
are via a terminal strip.
The amplifier module contains the electronic components for the
control of a proportional solenoid. Dependent on a positive voltage
signal present at the command value input the amplifier module
controls the solenoid. The actual value (position of the solenoid
armature) is signalled by an inductive position measuring system and
compared to the externally signalled command value. Occurring
differences between actual and command value are levelled out.
Through the connection of a positive voltage (UF > 8.5 V) at terminal
3 the controller and the output stage are enabled.

The following can be set externally via a trimming potentiometer:


The ramp time up to approx. 5 s
Command value reduction in a range of 0 % to 100 %
The zero point of the position transducer

Technical data (for applications outside these parameters, please consult us!)
Operating voltage
Function range:
Upper limiting range
Lower limiting range

UB
uB(t)max
uB(t)min

+ 24 VDC + 40 % 10 %

+ 39 V
+ 21 V

Max. current consumption

1.5 A

Fuse

2.5 A; slow blowing; after release self-activating

Inputs:
Differential input (command value input)
Enable
Active
Inactive
Demodulator input (positional measuring system)
Ramp time (setting range)
Outputs:
Output stage
Solenoid current / resistance
Pulse frequency
Driver for the inductive transducer
Oscillator frequency
Max. load capacity
Voltage amplitude (USS)
Max. stroke of the position transducer
Measuring points
Command value w
Position actual value x

Ue

0 to + 10 V; Re = 50 k (standard) 1)

UF
UF
Re

8.5 V < UF < 40 V


< 6.5 V
> 50 k

Imax
f
f
I

10 ms to 5 s

1.3 A; R(20) = 12.7


Free pulsating up to approx. 1.5 kHz

Ua
s

5,8 kHz 10 %
30 mA
5 V per output
3.8 mm

Uw
Ux

0 to + 5 V
0 to 5 V

Connection type

12-pin terminal strip

Housing dimensions (W x H x D)

40 x 79 x 85.5 mm

Permissible operating temperature range


Storage temperature range

t
t

0 to 50 C to DIN IEC 68-2 T1, T2, T14 and T30 2)


25 to + 85 C to DIN IEC 68-2 T1 and T2 2)

Interference immunity

Class 3 to prEN 50082 T2 2)

Mechanical loadability

To DIN IEC 68-2 T6, T24 and T27 2)

Weight

1)
2)

0.14 kg

Current input on request


Further details on request

RE 29 763/12.02

2/6

VT 11 019

275

Characteristics in the case of a fault

Error

Missing
enable (UF < 6.5 V)

Characteristics

of the electronics

Cable break
position transducer

E, R, A

E, R, A
1)

Abbreviation meaning:

Cable break
current input 1)
S, A

Only in special versions with a current


input of 4 to 20 mA (on request)

E = Output stage is switched off (solenoids are moved into a de-energised condition!)
R = Controller is switched off
S = Command value is set to 0 %
A = Multi-function display is illuminated

01

Block circuit diagram / connection allocation VT 11019 (from series 11)


Only in special versions with a current input of 4 to 20 mA (on request)

Enable + UF

PI

H1

u
i

Differential input
Ref. potential
+ Ucom.

4
5

u(i)

8
4

Gw

2 1

PD
2
t

+ UB
Operating voltage
0V

1
2

Gx

+ UM
M0
UM

+ DC
DC

power

Zx

12
11

2( )
1

10
(2)

Attention:
The connections to the position
transducer are shown for
clockwise rotation pumps
("( )" for anti-clockwise rotation
pumps)
1
2
3
4
5

Ramp generator
Controller for spool position
Current controller
Output stage
Oscillator/demodulator

VT 11 019

6
7
8
9
10

Power supply
Monitoring
Differential amplifier
Proportional valve
Position transducer

1
2
3
4

3/6

Actual value 0 to 5 V
Com. value 0 to + 5 V
Measuring zero
Measuring zero

H1
Zx
Gw
Gx
t

Multi-function display
Zero point position transducer
Command value reduction
Actual value matching
Ramp time

RE 26 763/12.02

276

Terminal connections

Operating
voltage

Enable
Differential
input

Position
transducer
connection 1)

+ UB

0V

UF

9 n.c.

Ref.
4
potential
+USoll 5
2

10 n.c.
11
12 1

1) Applies

Solenoid
connection

Position
transducer
connection 1)

to clockwise rotation pumps (see block circuit diagram)

Connection cable (recommendation):


Position transducer 3-core cable, single screened,
cross-section max. 1.5 mm2
Solenoid connection 2 or 4-core cable, single screened,
cross-section max. 1.5 mm2
Differential input
2-core cable, single screened

Unit dimensions

(Dimensions in mm)
Carrier rail NS 35/7,5
to DIN 50 022
7 8 9 10 11 12
REXROTH

VT 11019-1X
79

Gw
power t
H1

Gx
Zx
1

1 2 3 4 5 6

85,5

RE 29 763/12.02

40

4/6

H1:
Multi-function display (see page 2)
power:
Internal supply voltage
Gw:
Command value reduction
t:
Ramp time
Gx:
Actual value adjustment
Zx:
Position transducer zero point
Measuring socket 1: Actual value 0 to 5 V
Measuring socket 2: Command value 0 to + 5 V
Measuring socket 3: Measuring zero
Measuring socket 4: Measuring zero

VT 11 019

277

Engineering / maintenance guidelines / additional information


The amplifier module may only be connected when switched off!
Do not connect the earth terminal of the inductive transducer to ground!
Do not connect terminal 11 to ground, earth or screen; otherwise function disturbances may occur!
(this was also not permitted with series 10 units, but it did not lead to function disturbances.)
Always screen command value lines and lines of the inductive transducer separately; screen open at valve;
connect screen to 0V operating voltage (terminal 2) on module side only in order to avoid couplings!
Do not lay lines near power lines!
Do not use free wheel diodes in solenoid lines!
Distance to antenna lines, radio sources and radar equipment must be at least 1 m!
Because of the load current of the integrated smoothing capacitor external fuses must have slow blowing characteristics!
Attention: When using the differential input (command value as voltage signal) both inputs must always
be switched on or off simultaneously!
The actual value adjustment (potentiometer "Gx") is factory pre-calibrated!

01

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
E-mail: info@boschrexroth.co.uk

VT 11 019

5/6

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application can
be derived from our information. The details stated
do not release you from the responsibility for
carrying out your own assessment and verification.
It must be remembered that our products are
subject to a natural process of wear and ageing.

RE 29 763/12.02

278

Notes

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
E-mail: info@boschrexroth.co.uk

RE 29 763/12.02

6/6

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application can
be derived from our information. The details stated
do not release you from the responsibility for
carrying out your own assessment and verification.
It must be remembered that our products are
subject to a natural process of wear and ageing.

VT 11 019

279

RE 29743/06.05
Replaces: 02.05

Analogue amplifier module

1/4

Type VT11021

Component series 1X

H6507_d

Table of contents

Features

Features

Suitable for controlling servo-valves with mechanical feedback,


type 4WS2EM (sizes 6 and 10)

Ordering code

Differential input 10 V

Functional description

Dither signal generator

Block circuit diagram / pin assignment

U/I transformer (short-circuit-proof against 0 V)

Technical data

DC/DC converter

Terminal assignment

Reverse voltage protection

Unit dimensions

Signalling of internal supply voltage by LED

Contents

Page

Engineering / maintenance notes / supplementary information 4

Ordering code
VT 11021

1X

Amplifier module for servo-valves without electrical position


feedback;
types 4WS2EM 6 and 4WS2EM 10
Component series 10 to 19
(10 to19: unchanged technical data and pin assignment)

*
Further details in clear text

= 1X

280
2/4

Bosch Rexroth AG

Industrial Hydraulics

VT 11021 RE 29743/06.05

Functional description
The amplifier module is to be snapped onto a hat rails according to EN 60715. It is electrically connected by means of screw
terminals. The module is powered by 24V DC voltage.
The 10 V command value is applied to the differential input.
The output current of the downstream U/I transformer controls
the servo-valve.

The following parameters can be adjusted externally using


trimming potentiometers Gw, Zw and G D:
The max. output current between approx. 10 and 110 % by
means of Gw
The offset current between +10 % and 10 % of the max.
output current by means of Zw
The amplitude of the dither signals between 0 and 10 % of
the maximum output current by means of G D

Block circuit diagram / pin assignment

+
Differential input:
Ucomm: 0 to 10 V
Reference potential

6
3

Zw

Servo-valve

GD

Operating
voltage

0V

+ UM
M0
UM

DC

DC

Ucomm: 0 to 10 V I: 0 to 60 mA

Ucomm: 0 to +10 V I: 0 to +60 mA

3 4

+ UB

D
C

Gw

Power supply unit

Gw

Max. output current

Differential amplifier

Zw

Offset current

Summator

GD

Amplitude of dither signal

Dither signal generator

U/I transformer

281
RE 06.05/Entwurf

Industrial Hydraulics Bosch Rexroth AG

VT 11021

3/4

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC +40 % 10 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 21 V
Imax 300 mA

Current consumption (without valve) at UO = 24 V


Power consumption

PS approx. 8 VA

Fuse

Thermal overload fuse (with reactive function when temperature falls below the threshold)

Inputs:
Ucomm 0 to 10 V (Re 20 k)

Command value
Outputs:

Imax 60 mA +10 %

Valve current
Measuring sockets

Uw 0 to 10 V

Current command value w


Actual current value I

Uact 0 to 60 mV (10 mV 1 mA)

Dither signal:
Frequency

f 340 Hz 10 %

Amplitude

ISS 0 to 6 mA (factory setting 3 mA)

Type of connection

6 screw terminals

Type of mounting

Hat rail TH35-7.5 according to EN 60715

Type of protection

IP 20 to EN 60529

Dimensions (W x H x D)

25 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

20 to +70 C

Weight

m 0.13 kg

Terminal assignment

Operating
voltage

+UO

Servo(supply)
valve

0V

Servovalve

Reference
potential

Ucomm

Terminals 3 and 6: Differential input

01

282
4/4

Bosch Rexroth AG

Industrial Hydraulics

VT 11021

RE 29743/06.05

Unit dimensions
Hat rail TH 35-7.5
to EN 60715

Adjustment / indicator element

4 5 6

Potentiometers:

REXROTH
VT 11021

79

Factory setting

Gw
Zw
GD

Gw

max. output current

60 mA (100 %)

Zw

offset current

0 mA

GD

amplitude of dither signal 3 mA

LED indicator lamp:


green

w I

internal supply voltage

Measuring sockets:
1 2 3
85,5

25

current command value (10 V 100 %)

actual current value (10 mV 1 mA)

measuring zero

Engineering / maintenance notes / supplementary information


The amplifier module may only be wired when disconnected from the power supply!
The distance to radio equipment must be sufficiently large (>> 1m)!
Shield command value cables; do not lay them near power cables!
Do not use free-wheeling diodes in the solenoid cables!
In the case of a strong fluctuations in the operating voltage, it may become necessary to install an external smoothing capacitor
having a capacitance of at least 2200 F.
Recommendation:

Capacitor module VT 11073 (see RE 29750); sufficient for up to 3 amplifier modules

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

283

RE 30264/07.05

Plug amplifier module


for proportional valves

1/8

Type VT-SSPA1

Unit series 2X

List of contents

Features

Features

Analog amplifier for actuating proportional valves (pressure


and directional control valves) without position control

Ordering data

Differential input

Preferred types

Adjustable ramp time (10 ms...5 s)

Function

Adjustable sensitivity, valve zero and dither frequency

Connections/calibration

Operating voltage 24 V

Contents

Circuit diagram/pin assignment


Commissioning/adjustment

Page

3
4 and 5

Technical data

Unit dimensions

Testing and service equipment


Current measuring adapter VT-PA-5, see RE 30073

284
2/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1

RE 30264/07.05

Ordering data

VT
Construction
Plug amplifier
Hydraulic component
For valves without electrical
feedback
Valve type
Proportional valve
Actuation
Analog

2X V0

I=

V0 =

2X =

508 =
525 =

=A

=1

Material Number

For valve types

VTSSPA152520/V0

0 811 405 143

see valve group A

VTSSPA150820/V0

0 811 405 144

see valve group B

VTSSPA152520/V0/I

0 811 405 145

see valve group A

VTSSPA150820/V0/I

0 811 405 162

see valve group B

Valve group A

Valve group B

DBETX...25

DBETX...8

DBE6X...25

DBE6X...8

DRE6X...25

DRE6X...8

DBE10Z...25

DBE10Z...8

DRE10Z...25

DRE10Z...8

3FREX10
4WRBA..EA

Unit series
Unit series 20 to 29

=P

Type

3FREX6

Customer version
Catalog version

=S

Preferred types

2FREX10

Optional extras
Actuation 4...20 mA

=S

Output stages
1 output stage

2FREX6

Serial numbers for types


0.8 A solenoid
2.5 A solenoid

285
RE 30264/07.05

VT-SSPA1

Hydraulics Bosch Rexroth AG

3/8

Function
The plug amplifier is employed for actuating proportional
valves without position control.
It is plugged directly into the valves solenoid plug.
The connecting cable (UB, setpoint) on the control side is
routed through a compression gland and connected.
A LED lights up when the power supply is switched on. The
setpoint input takes the form of either voltage 0...10 V or
current 4...20 mA, depending on the type of plug amplifier.

The setpoint can be adjusted in terms of zero and sensitivity.


In the case of voltage input, a differential input is available.
In addition, the setpoint can be run using a ramp.
The dither amplitude is variable, allowing the system to be
adapted to suit special-purpose applications. On delivery, the
dither amplitude is already set to an optimum value, so that
further adjustment is only necessary in special cases, as
mentioned above.

01
Connections/calibration

P1
P2
P3
P4
St 1
LED

Circuit diagram/pin assignment

1)
2)

0 811 405 143; 0 811 405 144


0 811 405 145; 0 811 405 162

Ramp time
Sensitivity
Zero
Dither frequency
Terminal
UB display

286
4/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1

Commissioning/adjustment
1. Prepare the connecting cable.

Wire end ferrules with short crimp (5x)

2. Route cable through the compression gland


and connect to terminal St 1.
Caution
Do not switch on the power supply or input
the setpoint for the cable yet!

3. Switch on the power supply

LED lights up (green).


4. Zero adjustment pot. P3,
with minimum setpoint input.
5. Sensitivity adjustment pot. P2,
with maximum setpoint input.

0 811 405 143


0 811 405 145

0 811 405 144


0 811 405 162

RE 30264/07.05

287
RE 30264/07.05

Hydraulics Bosch Rexroth AG

VT-SSPA1

5/8

Commissioning/adjustment
6. Dither frequency adjustment
pot. P4.

Dither frequency adjustment range

The dither frequency is already correctly set on delivery,


but correction may be required for special applications. If so,
please consult BRH-CO/SPI.

01

Factory setting

P4

Pot. setting

Ramp time adjustment range

7. Ramp time adjustment


(acceleration and deceleration)
pot. P1.

Factory setting

CW

P1

Pot. rotation

288
6/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1

Technical data
Specifications
Construction
Connections

Plug housing
Solenoid
UB, setpoint

DIN 43650
Cable 5x0.75 mm2, shielded
(incl. PE)

Ambient temperature

C 20...+70

Storage temperature

C 20 min.

Degree of protection

IP 65, plugged in

Power supply nom. 24 V DC


Solenoid 2.5 A

Battery voltage 10.2...31 V


Rectified AC voltage 10.2...27 V

Solenoid 0.8 A

Battery voltage 21...31 V


Rectified voltage 21...27 V

Residual ripple
Power consumption
Setpoint

Output

< 2 VSS
55 VA max, see valve data

0 811 405 143


0 811 405 144

0...10 V DC

0 811 405 145


0 811 405 162

4...20 mA

0 811 405 145


0 811 405 143

Imax = 2.5 A (square-wave voltage, pulse-modulated)

0 811 405 144


0 811 405 162

Imax = 0.8 A (square-wave voltage, pulse-modulated)

Ramp time

s 60 ms...4.5

Dither frequency range

95...340 Hz as an option

Zero adjustment range

See characteristic curves on page 4

Sensitivity adjustment range


Special features

Conformity

LED (green): power supply on


Short-circuit-proof inputs and outputs
Clocked output stage
Rapid energizing for fast response times
Adjustment via trimming potentiometer
EN 61000-6-2: 2002-08
EN 61000-6-3: 2002-08

RE 30264/07.05

289
RE 30264/07.05

VT-SSPA1

Hydraulics Bosch Rexroth AG

7/8

Unit dimensions (nominal dimensions in mm)

01

290
8/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1

RE 30264/07.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not release
the user from the obligation of own judgement and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

291

Plug-in proportional amplifier

RE 30265/09.05

1/8

Type VT-SSPA1-1, VT-SSPA1-50

Component series 1X
HAD 7072

Table of contents
Contents

Features
Page

Features

Ordering code

Overview of types

Possible applications

Block circuit diagram

Characteristic curve

Function

Technical data

Terminal assignment

Section / control elements / dimensions

Engineering / maintenance notes /


supplementary information

Used for controlling solenoid operated DBET-6X pressure


control valves without closed-loop position control
Proportional command value / flow characteristic curve for
command values between 0 % and 100 %
Regulated, adjustable maximum current for a command value
greater than approx. 120 % (only with differential input )
Differential input, optional current input
Ramp generator, up/down separated
Zero potentiometer / biasing current
Command value attenuator / maximum current
Dither frequency potentiometer
Operating voltage 24 V

292
2/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-1, VT-SSPA1-50

RE 30265/09.05

Ordering code
VT SSPA1
For DBET-6X
Universal

1X V0

*
Further details in clear text

=1
= 50

24 =

24 V application

0=
I=

Voltage input
Current input

Overview of types
Type

Mat. no.

UO

Inom

f at Inom

Comm. value

For valve

Solenoid

VT-SSPA1-1-1X/V0/0-24

R900779643

24 V

1.6

340 Hz

0-10 V/24 V

DBET-6X

5.5 Ohm

1.6 A

VT-SSPA1-1-1X/V0/I-24

R901029782

24 V

1.6

340 Hz

4-20 mA

DBET-6X

5.5 Ohm

1.6 A

VT-SSPA1-50-1X/V0/0-24

R901005414

24 V

2.5

305 Hz

0-10 V/24 V

universal

> 2 Ohm

2.5 A

VT-SSPA1-50-1X/V0/I-24

R901029783

24 V

2.5

305 Hz

4-20 mA

universal

> 2 Ohm

2.5 A

293
RE 30265/09.05

3/8

Hydraulics Bosch Rexroth AG

VT-SSPA1-1, VT-SSPA1-50

Possible applications
2-conductor technology (only with differential input)
U/I

Ramp function when switched on


The IN+ input is to be bridged with the supply voltage (+UO)
in the plug-in connector, the IN input is to be bridged with
the supply voltage (0 V) in the plug-in connector.

IN+

Switching applications with constant-current regulation

U
IN

The maximum current must usually be matched according to


the solenoid data using potentiometer G. The ramp time
ramp up (t <) can be adjusted within the range of
60 ms to 5 s.

t<

+UB
10uF

UB = 24 V

t>
U

DC
DC

0V

0V

PE

01
3-conductor technology (only with differential input)
Switching applications with constant-current regulation
Switching with low control power
Ramp function, when the control voltage is switched on or
off, can be separately adjusted

US = 24 V

IN+
U/I

The IN+ input is to be connected to the control voltage (Uc


= 24 V / 12 V), the IN input is to be bridged with the supply
voltage (0 V) in the plug-in connector.

U
IN
+UB
10uF

UB = 24 V

The maximum current must usually be matched according to


the solenoid data using potentiometer G. In the de-energised
condition (IN+ = 0 V or IN+ = open) a biasing current
can be set on Z. This biasing current can be used to reduce
the switch-on delay, especially in conjunction with a ramp. If
required, a value of between approx. 20 mA and approx. 15 %
of the nominal current can be set. The ramp times ramp up
(t <) and ramp down (t >) can be adjusted within the range
of 60 ms to 5 s.

t<

t>
U

DC
DC

0V

0V

PE

4-conductor technology
The IN+ input is to be connected to control signal UC = 0 V
to 10 V or Is = 4 mA to 20 mA, the IN input is to be connected to the reference potential of the control voltage.
The biasing current and the maximum current have to be
adjusted by means of potentiometers Z and G before commissioning. The current can then be adjusted proportionally
between the set biasing current and the set maximum current
according to the control voltage. The biasing current can be
adjusted within the range of approx. 0 mA to approx. 15 % of
the nominal current, the maximum current within the range of
0 to Imax (see technical data on page 5).

IN+
0 - 10 V
4 - 20 mA

U/I

U/I
U
IN
+UB
10uF

24 V

t>
U

DC
DC

0V
PE

t<

294
4/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-1, VT-SSPA1-50

RE 30265/09.05

Block circuit diagram

(1): Internal voltage adjustment


Sollwert

(2): Command value input


(3): Zero point potentiometer Z / biasing current I (IN = 0%)

U/I
U

IN

(4): Command value attenuator G / maximum current I (IN = 100%)


(5): Ramp time potentiometers t < and t >

(2)

(6): Frequency range correction f


(7): Current output stage
0V

0V

t>
(5)

t<

+UB
10uF

24 V

(3)

IN+

DC

(4)
1
(7)

(6)

DC
(1)

f
PE

Characteristic curve
Actual value
Imax
With factory setting

IO (0%)
Note!

0%

Depending on the type, the biasing current can also be 0.

100 %
approx. 110 %

Max. command value


= 35 V

Adjustment range

Inom (100%)

UO

Command value

Function
The plug-in amplifier is suitable for mounting onto a valve connection base according to DIN 43650 / ISO 4400. By turning
the plug insert and the electronics in the housing, the plug-in
amplifier can be mounted on the solenoid in 90 increments.

switching off, with 3-wire connection only, i.e. switching signal


and supply are connected separately). This characteristic also
depends on the valve and solenoid type. The downstream command value attenuator (4) has no influence on the ramp time

Connection / grounding

Characteristic curve

The connection to the control is to be made by means of a 2-,


3- or 4-wire cable depending on the application. If the protective conductor is to be connected, the number of wires must
be adjusted accordingly. The protective conductor is to be
connected directly on the corresponding screw-type contact of
the plug insert.

Up to a command value of approx. 110 % the transfer characteristic curve rises linearly. The zero point can be corrected by
means of potentiometer Z, the maximum value using potentiometer G.

Command value feedforward


The command value range is between 0 and UO. In the command value range of 0-10 V or 4-20 mA, the solenoid current
is proportional to the command value. From a command value
of approx. 110 % up to UO the solenoid current is almost constant according to the Imax setting (switching application).
Ramp generator
Ramp generator (5) limits the gradient of the control variable.
The ramp times can be adjusted separately for up and down
ramps. In switching applications, the ramps can be used to
dampen the switch-on and switch-off impulse (in the case of

Current output stage


Output stage (7) is self-clocking. The clock frequency depends
on the current intensity, the operating voltage and the impedance of the controlled solenoids. The clock frequency can be
re-adjusted by means of potentiometer f. The current output
stage generates a regulated current signal according to the
control variable provided by summator (3). Too high a clock frequency results in an increase in the valve hysteresis. Too low a
clock frequency increases the noise level of the hydraulic system.

295
RE 30265/09.05

Hydraulics Bosch Rexroth AG

VT-SSPA1-1, VT-SSPA1-50

5/8

Technical data (for applications outside these parameters, please consult us!)
Type
Operating voltage 24 V

Maximum cable inductance1)

VT-SSPA1-1

VT-SSPA1-50
24 VDC

UO
u(t)max

35 V

u(t)min

18 V
100 H

Lmax

Current / power consumption

< 1.7 A

< 2.6 A

(depending on solenoid data)

Pmax

< 40 VA

< 60 VA

2 AT

3.15 AT

> 15 mH

> 10 mH

0 to 300 mA

0 to 450 mA

1.6 A

2.5 A

IB to 1.7 A

IB to 2.6 A

Recommended back-up fuse


Minimum coil inductance
Biasing current (adjustment range)

Lmin
IB

Nominal current (with factory setting)


Maximum current (adjustment range)
Command value input (voltage)

Imax
U

Proportional range

0 to 10 V

Switching range

12 V to UO

Resistance
Option: Command value input (current)
Proportional range
Ramp time (adjustment range)

20 k
I

4 to 20 mA / Ri = 100

60 ms to 5 s

Type of connection (cable)

4 screw-type terminals

Type of connection (solenoid)

Base to DIN 43650 / ISO4400

Number of pins (solenoid)

2 + PE

Cable diameter

4.5 11 mm

Dimensions

40 x 38 x 70 mm (WxHxD)

Type of mounting

M3 x 40

Permissible operating temperature range

Storage temperature range

Type of protection
Weight
Clock frequency

IP65 to EN 60529
m

2)

0.125 kg

f
DBET-6X

1)

25 to +85 C
25 to +70 C 2)
25 C to +85 C

Usually corresponds to a cable length greater than 100 m


Valid for solenoid currents > 2 A and a clock frequency > 350 Hz

160 Hz to 380 Hz (340 Hz at Inom)

01

296
6/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-1, VT-SSPA1-50

RE 30265/09.05

Terminal assignment
Terminal

Terminal

+UB

Operating voltage UO
+24 V

IN+

+ command value input


+24 V: 0 to +10 V / 4 to 20 mA

0V

0 V ground

IN

Reference potenial for command value

Section / control elements / dimensions (in mm)


Top view with open housing:
G:

Command value attenuator / maximum current

Z:

Zero point potentiometer / biasing current

t <: Ramp time up


t >: Ramp time down
Frequency range

t<

IN+

IN

+UB
61,75

0V

25

ca. 38

34

18

t> G

5,5

f:

ca. 71

34

297
RE 30265/09.05

VT-SSPA1-1, VT-SSPA1-50

Hydraulics Bosch Rexroth AG

7/8

Engineering / maintenance notes / supplementary information


The plug-in amplifier may only be wired when disconnected from the power supply.
Do not lay cables near power cables!
The distance to aerial lines, radio sources and radar equipment must be at least 1m.
Use a measuring adapter for adjusting the potentiometers and for checking the current values, and measure currents electrically
isolated.
The specified maximum solenoid currents must not be exceeded.
Do not use solenoids with integrated free-wheeling diodes.
The supply voltage must be protected by means of a fuse - see technical data.
Note:
The solenoids are controlled with a clocked voltage. The intensity of the solenoid voltage impulse corresponds to the applied operating voltage (+UO).
Solenoids with integrated EMC suppressor circuit may only be used, if the permissible solenoid voltage - both, for positive and
negative voltage - is greater than the actual operating voltage.
Solenoids without EMC suppressor circuit may usually be operated up to their nominal current.
Please observe the manufacturers information.
Caution:
VT-SSPA1-50 amplifiers are indented for universal use and are not adapted to specific valves.
In the case of a strongly fluctuating operating voltage, it may be required to provide an external smoothing capacitor having a capacitance of approx. 470 F to 2200 F.
Recommendation: Capacitor module VT 11073 (see RE 29750) sufficient for up to 10 plug-in amplifiers
The cable length should not exceed 20 m
Cable recommendation: 4 x 0.75 mm2, shielded, or 5 x 0.5 mm2, shielded

01

298
8/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-1, VT-SSPA1-50

RE 30265/09.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

299

Plug-in proportional amplifier

RE 30116/09.05
Replaces: 10.03

1/8

Type VT-SSPA1-5, VT-SSPA1-100

Component series 1X
HAD 7072

Table of contents
Contents

Features
Page

Features

Ordering code

Overview of types

Possible applications

Block circuit diagram

Characteristic curve

Function

Technical data

Terminal assignment

View / control elements / dimensions

Engineering / maintenance notes /


supplementary information

Used for controlling solenoid operated pressure control 1) and


directional valves 2) without closed-loop position control
Proportional command value / current characteristic curves for
command values from 0 % to 100 %
Regulated, adjustable maximum current for a command value
greater than approx. 120 % (only with differential input)
Differential input, optional current input
Ramp generator, separate for up/down
Zero potentiometer / biasing current
Command value attenuator / maximum current
Dither frequency potentiometer
Operating voltage 24 V / 12 V
1)

Especially of type

KBPS...8

2)

Especially of type

KKDSR1...
KKDSR2...

300
2/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-5, VT-SSPA1-100

RE 30116/09.05

Ordering code
VT SSPA1
for KBPS...8
for KKDSR

1X V0

*
Further details in clear text

=5
= 100

12 =
24 =

12 V application
24 V application

0=
I=

Voltage input
Current input

Overview of types
Type

Mat. no.

UO

Inom

f at Inom

Command value

For valve

Solenoid

VT-SSPA1-5-1X/V0/0-24

R901024331

24 V

1.2

200 Hz

0-10 V/24 V

KBPS...8

4.77 Ohm

1.2 A

VT-SSPA1-5-1X/V0/I-24

R901046147

24 V

1.2

200 Hz

4-20 mA

KBPS...8

4.77 Ohm

1.2 A

VT-SSPA1-5-1X/V0/0-12

R901046149

12 V

1.76

230 Hz

0-5 V/12 V

KBPS...8

2.3 Ohm

1.76 A

VT-SSPA1-5-1X/V0/I-12

R901046244

12 V

1.76

230 Hz

4-20 mA

KBPS...8

2.3 Ohm

1.76 A

VT-SSPA1-100-1X/V0/0-24

R901030116

24 V

1.2

150 Hz

0-10 V/24 V

KKDSR1

7.2 Ohm

1.2 A

VT-SSPA1-100-1X/V0/I-24

R901030114

24 V

1.2

150 Hz

4-20 mA

KKDSR1

7.2 Ohm

1.2 A

VT-SSPA1-100-1X/V0/0-12

R901030117

12 V

1.8

130 Hz

0-5 V/12 V

KKDSR1

3.3 Ohm

1.8 A

VT-SSPA1-100-1X/V0/I-12

R901030115

12 V

1.8

130 Hz

4-20 mA

KKDSR1

3.3 Ohm

1.8 A

301
RE 30116/09.05

3/8

Hydraulics Bosch Rexroth AG

VT-SSPA1-5, VT-SSPA1-100

Possible applications
2-conductor technology (only with differential input)
Z

IN+

Switching applications with constant-current regulation

U/I

Ramp function when switched on

The IN+ input is to be bridged with the supply voltage (+UO)


in the plug-in connector, the IN input is to be bridged with
UB = 24 V
the supply voltage (0 V) in the plug-in connector.

IN

t>

t<

+UB
10uF

DC
DC

The maximum current must usually be matched according to


the solenoid data using potentiometer G. The ramp time
ramp up (t <) can be adjusted within the range of
60 ms to 5 s.

0V

0V

PE

01
3-conductor technology (only with differential input)
Switching applications with constant-current regulation
Switching with low control power
Ramp function, when the control voltage is switched on or
off, can be separately adjusted
The IN+ input is to be connected to the control voltage (Uc
= 24 V / 12 V), the IN input is to be bridged with the supply
voltage (0 V) in the plug-in connector.

US = 24 V

IN+
U/I
U
IN
+UB
10uF

UB = 24 V

The maximum current must usually be matched according to


the solenoid data using potentiometer G. In the de-energised
condition (IN+ = 0 V or IN+ = open) a biasing current
can be set on Z. This biasing current can be used to reduce
the switch-on delay, especially in conjunction with a ramp. If
required, a value of between approx. 20 mA and approx. 15 %
of the nominal current can be set. The ramp times ramp up
(t <) and ramp down (t >) can be adjusted within the range
of 60 ms to 5 s.

t>

t<

DC
DC

0V

0V

PE

4-conductor technology
The IN+ input is to be connected to the control signal (24
V = Uc = 0 V to 10 V or Ic = 4 mA to 20 mA / 12 V = Uc =
0 V to 5 V or Ic = 4 mA to 20 mA), the IN input is to be
connected to the reference potential of the control voltage.
The biasing current and the maximum current have to be
adjusted by means of potentiometers Z and G before commissioning. The current can then be adjusted proportionally
between the set biasing current and the set maximum current
according to the control voltage. The biasing current can be
adjusted within the range of approx. 0 mA to approx. 15 % of
the nominal current, the maximum current within the range of
0 to Imax (see technical data on page 5).

IN+
0 - 5 V / 12 V
0 - 10 V / 24 V
4 - 20 mA

U/I

U/I
U
IN
+UB
10uF

24/12 V

t>
U

DC
DC

0V
PE

t<

302
4/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-5, VT-SSPA1-100

RE 30116/09.05

Block circuit diagram

(1): Internal voltage adjustment

(3)

IN+
Sollwert (2) U/I
U

(2): Command value input


(3): Zero point potentiometer Z / biasing current I (IN = 0%)

IN

(4): Command value attenuator G / maximum current I (IN = 100%)


(5): Ramp time potentiometers t < and t >

24 / 12 V

(6): Frequency range correction f

+UB
10uF

(7): Current output stage


0V

0V

t>
(5)

t<

DC

(4)
1
(7)

(6)

DC
(1)

f
PE

Characteristic curve
Actual value
Imax
With factory setting

IB (0%)
Note!

0%

Depending on the type, the biasing current can also be 0.

Function

100 %
Approx. 110 %

Max. command value = 35 V

Adjustment range

Inom (100%)

UO

Command value

The plug-in amplifier is suitable for mounting onto a valve connection base according to DIN 43650 / ISO 4400. By turning
the plug insert and the electronics in the housing, the plug-in
amplifier can be mounted on the solenoid in 90 increments.

and supply are connected separately). This characteristic also


depends on the valve and solenoid type. The downstream command value attenuator (4) has no influence on the ramp time.

Connection / grounding

Up to a command value of approx. 110 % the transfer characteristic curve rises linearly. The zero point can be corrected by
means of potentiometer Z, the maximum value using potentiometer G.

The connection to the control is made by means of a 2-, 3- or


4-wire cable depending on the application. If the protective
conductor is to be connected, the number of wires must be
adjusted accordingly. The protective conductor is to be connected directly on the corresponding screw-type contact of the
plug insert.
Command value feedforward
The command value range is between 0 and UO. In the command value range 0-5 V, 0-10 V or 4-20 mA, the solenoid current is proportional to the command value. From a command
value of approx. 100 % up to UO the solenoid current is almost
constant according to the Imax setting (switching application).
Ramp generator
Ramp generator (5) limits the gradient of the control variable.
The ramp times can be adjusted separately for up and down
ramps. In switching applications, the ramps can be used to
dampen the switch-on and switch-off impulse (in the case of
switching off, with 3-wire connection only, i.e. switching signal

Characteristic curve

Current output stage


Output stage (7) is self-clocking. The clock frequency depends
on the current intensity, operating voltage and the impedance
of the controlled solenoid. The clock frequency can be re-adjusted by means of potentiometer f. The current output stage
generates a regulated current signal according to the control
variable provided by summator (3). Too high a clock frequency
results in an increase in the valve hysteresis. Too low a clock
frequency increases the noise level of the hydraulic system.

303
RE 30116/09.05

Hydraulics Bosch Rexroth AG

VT-SSPA1-5, VT-SSPA1-100

5/8

Technical data (for applications outside these parameters, please consult us!)
Type
Operating voltage 24 V

Operating voltage 12 V

VT-SSPA1-5
UO

VTSSPA1-100
24 VDC

u(t)max

35 V

u(t)min

18 V

UO

12 VDC

u(t)max

16 V

u(t)min

8V

Maximum cable inductance 1)

Lmax

100 H

Current / power consumption

< 1.7 A

(depending on solenoid data)

Pmax

< 40 VA

Recommended back-up fuse


Minimum coil inductance
Biasing current (adjustment range)

2 AT
Lmin
IB

Nominal current (factory setting)


Maximum current (adjustment range)
Command value input (voltage)

Imax

12 V to UO (6 V to UO with option 12V)

Resistance

20 k
I

4 20 mA / Ri = 100

60 ms to 5 s

Type of connection (cable)

4 screw terminals

Type of connection (solenoid)

Base to DIN 43650 / ISO4400

Number of pins (solenoid)

2 + PE

Cable diameter

4.5 11 mm

Dimensions

40 x 38 x 70 mm (WxHxD)

Type of mounting

M3 x 40

Permissible operating temperature range

Storage temperature range

Type of protection

Clock frequency

1)
2)

Option 24 V: 1.2 A
Option 12 V: 1.8 A
IB to 1.9 A

0 to 10 V (0 to 5 V with option 12 V)

Switching range

Weight

0 to 300 mA

Proportional range

Option: Command value input (current)


Proportional range
Ramp time (adjustment range)

> 10 mH

25 to +85 C
25 to +70 C 2)
25C to +85 C
IP65 to EN 60529

0.125 kg

f
KBPS...8

160 Hz to 350 Hz (200 Hz at Inom) (option 24 V)

KKDSR1

120 Hz to 160 Hz (150 Hz bat Inom) (option 24 V)

KKDSR2

On enquiry

Usually corresponds to a cable length greater than 100 m


Valid for solenoid currents > 2 A and a clock frequency > 350 Hz

01

304
6/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-5, VT-SSPA1-100

RE 30116/09.05

Terminal assignment
Terminal

Terminal

+UO

Operating voltage UO
+24 V / +12 V

IN+

0 V ground

IN

0V

+command value input


+24 V: 0 to +10 V / 420 mA
+12 V: 0 to +5 V / 420 mA
Reference potential for command value

View / control elements / dimensions (in mm)


Top view on open housing:
G:

Command value attenuator / maximum current

Z:

Zero point potentiometer / biasing current

t <: Ramp time up


t >: Ramp time down
Frequency range

t<

IN+

IN

+UB
61,75

0V

25

ca. 38

34

18

t> G

5,5

f:

ca. 71

34

305
RE 30116/09.05

VT-SSPA1-5, VT-SSPA1-100

Hydraulics Bosch Rexroth AG

7/8

Engineering / maintenance notes / supplementary information


The plug-in amplifier may only be wired when disconnected from the power supply.
Do not lay cables near power cables!
The distance to aerial lines, radio sources and radar equipment must be at least 1m.
Use a measuring adapter for adjusting the potentiometers and for checking the current values and measure currents electrically
isolated.
The specified maximum solenoid currents must not be exceeded.
Do not use solenoids with integrated free-wheeling diodes.
The supply voltage must be protected by means of a fuse - see technical data.
Note:
The solenoids are controlled with a clocked voltage. The intensity of the solenoid voltage impulse corresponds to the applied operating voltage (+UO).
Solenoids with integrated EMC suppressor circuit may only be used, if the permissible solenoid voltage - both, for positive and
negative voltage - is greater than the actual operating voltage.
Solenoids without EMC suppressor circuit may usually be operated up to their nominal current.
Please observe the manufacturers information.
Caution:
In the case of strongly fluctuating operating voltage, it may be required to provide an external smoothing capacitor having a capacitance of approx. 470 F to 2200 F.
Recommendation: Capacitor module VT 11073 (see RE 29750) sufficient for up to 10 plug-in amplifiers
The cable length should not exceed 20 m
Cable recommendation: 4 x 0.75 mm2, shielded, or 5 x 0.5 mm2, shielded

01

306
8/8

Bosch Rexroth AG

Hydraulics

VT-SSPA1-5, VT-SSPA1-100

RE 30116/09.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

307

Digital valve amplifier for


valve types
4WRE 6, component series 2X
4WRE 10, component series 2X

RE 30126/09.05
Replaces: 05.05

1/8

Type VT-VRPD-2

Component series 2X

H7356_d

Table of contents
Contents

Features
Page

Features

Ordering code

Functional description

Block circuit diagram

Technical data

Pin assignment of the male connector

Pin assignment of the D-Sub socket on the front panel

Unit dimensions

Engineering / maintenance notes / supplementary information

Suitable card holders:


19 racks, VT 19101, VT 19102, VT 19103 and VT 19110 (see
RE 29768)
Enclosed card holder VT 12302-3X (see RE 30103)
Open card holder VT 3002-2X/64G (see RE 29928)
For installation in control cabinets only!
Connection adapter VT 10812-2X/64G (see RE 30105)

Suitable for controlling proportional valves with electrical position feedback, types:
4WRE 6, component series 2X
4WRE 10, component series 2X
User data can be exactly reproduced and are protected
against unintended or unauthorized changes
Use of a powerful microcontroller
Valve selection using operating software BODAC
Command value input, optional as voltage or current interface
Voltage input as differential input
Command value input with variable input adjustment
Ramp generator
Digital inputs for calling pre-set command value parameters
Enable input and fault output
Switched-mode power supply unit for internal supply voltages
Freely configurable measuring sockets X2 (X1 positively assigned to actual valve value)
Configuration and parameterization via serial interface using
PC software BODAC (CD:SYS-HACD-BODAC-01)
Connecting cable for BODAC
Further information and operation
For instructions regarding the installation of VT-VRPD, see
RE 30126-B
Operating instructions for BODAC for VT-VRPD-2-2X,
see RE 30126-01-B

308
2/8

Bosch Rexroth AG

Hydraulics

RE 30126/09.05

VT-VRPD-2

Ordering code
Order for complete amplifier

VT-VRPD

2X V0

1
1=
With valve output stage
(Caution: Only suitable for valve with
two solenoids!)

Digital amplifier for proportional valves


with electrical position feedback
Amplifier for valve types 4WRE 6 and 4WRE 10
(component series 2X)

=2

Component series 20 to 29
(20 to 29: unchanged technical data and pin assignment)

0=

Basic component

0=

= 2X

Without display

V0 =

Basic component

Functional description
The amplifier card is designed as double-sided printed-circuit
board in Euro-format 100 x 160 mm with daughterboard.
A microcontroller is the central unit of the amplifier. It controls
the entire sequence and implements closed-loop position control. Board-spedific data (configuration, command value feedforward, parameters) are saved in the non-volatile FLASH.
Four binary-coded, digital inputs are used for calling parameter
sets (command values) from the memory, in which a maximum
of 16 sets can be saved. A call-up activates the command value for the valve spool position with the associated ramp times.
Further control inputs have the following function:
Command valid:

Enable of the parameter set addressed by


the current call-up (H-active)

Enable:

Activation of outputs (fault message acknowledgement by L/H)

Remark:

H-active = High-active, 15 V to UO
L-active = Low-active, 0 V to 5 V
L/H edge = LowHigh edge
The amplifier card includes a controller for the spool position of
a proportional valve.
The command value can be fed forward via digital command
value call-ups (5) and/or via analogue inputs (1). Analogue input E1 (b14/b16) must be used for command values of 10 V,
analogue input E2 (b22/b24) for command values of 4 to
20 mA.
The digital command value is added to the analogue command
value with the correct sign in accordance with the set call-up.
The signal level of the command value inputs can be varied by
means of the software.
Apart from the possibility of generating ramps internally, it is
possible to influence up and down ramps of external signals
with correct sums and signs by means of analogue inputs E3
(b6/b9) and E4 (b18/b20).
For 4WRE valves, a step function generator (9) is provided by
the software when a spool with overlap is selected. The command value sum is fed to the controller (12).
The actual valve value (b26) is generated by means of an
oscillator/demodulator stage from the position measuring system of the valve and also fed to the controller (12). The controller output controls the current-regulated output stages.
Enable and fault messages
The closed-loop control is activated by an H-level at the enable

input. If no command value call-up is active, digital call-up 0 is


set.
A fault logic (14) recognises system deviations, a cable break
of the actual value cables and of the command value input for
4 to 20 mA as well as an inactive enable input. In the case of
a fault, a fault message is output to (d22) by a Low signal and
signalled visually by LED OK (OK goes out) on the front panel. It is possible to configure the enable so that an inactive enable input is not signalled as a fault.
Parameterisation and diagnosis
The selection of the valve to be controlled and the selection
and configuration of the command value input, the ramp generator, the enable input and the setting of the command value
call-up parameters are made via the serial interface [6] at the
front D-SUB socket [7].
Digital outputs
DO 1

(d20)

Solenoid A active

DO 2

(d26)

Solenoid B active

DO 3

(z22)

System deviation window

DO 4

(z24)

Freely configurable

DO 5

(z26)

Freely configurable

DO 6

(z28)

Freely configurable

DO 7

(f2)

Not assigned

Indicator elements and measuring sockets


The front panel of the command value card is provided with
measuring sockets for the two analogue outputs.
Measuring socket X2:

Valve command value (default)

Measuring socket X1:

Actual valve value (b26)

Measuring socket :

Reference potential (corresponds


to connection z32)

The following states are signalled by LEDs:


LED (green):

Enable active

LED OK (green):

OK ready for operation

LEDs I1...I4 (yellow):

Binary-coded command value call-ups

LED I6 (yellow)

Command valid

LED I5, I7 (yellow)

Not assigned

( ) = Cross-reference to block circuit diagram on page 3

11
12
13
14
15

Control of binary call-ups


Characteristic curve adjustment
Step function generator
Offset
Limitation

7
8
9
10

Switching matrix

Switched-mode power supply unit

Binary command value call-ups

Control of
binary callups

Binary 0
Binary 15

LC1

DC

S-samp end

S-ramp start

Ramp down

Comm. value internal Ramp up

Analogue input adjustment

DC

C1

U/U or I/U converter

z32

z30

z20

z10

d18

Command valid

d12

BINARY 1
BINARY 2
BINARY 4
BINARY 8

d2
d4
d6
d8

b20

b18

b8

b6

b24

b22

b16

b14

0V

+ UB

DI 1
DI 2
DI 3
DI 4
DI 5
DI 6

E4

E3

E2

E1

10

14

PID

Fault logic

Digital outputs

Measuring sockets

Oscillator / demodulator

PID-controller

11

X2X1

15

b30
b32

d22

d20
d26
z22
z24
z26
z28
f2

Actual valve value


Valve command value (default)
Reference potential (0 V)

X1
X2

10V
+ 10V

OK

DO 1
DO 2
DO 3
DO 4
DO 5
DO 6
DO 7

b26 Valve comm.


b28 value ( 10 V)

z14
z10

2
3

z12
z16

Solenoid A
z18

Measuring sockets:

Solenoid A active
Solenoid B active
System deviation > window
Freely configurable
Freely configurable
Freely configurable
Not assigned

13

12

1
2

z2
z4

i
PI

z8

PI

Solenoid B
z6

VT-VRPD-2

Enable

Voltage input
(10 V)
Current input
(4 - 20 mA)
External ramp
up (0 - 10 V)
External ramp
down (0 - 10 V)

RE 30126/09.05

309
Hydraulics Bosch Rexroth AG
3/8

Block circuit diagram / pin assignment VT-VRPD-2

01

310
4/8

Bosch Rexroth AG

Hydraulics

VT-VRPD-2

RE 30126/09.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC + 40 % 10 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 21 V

Current consumption

Imax 1.5 A; stand-by current 270 mA

Fuse

IS 4 A slow

Digital inputs

U Low = 0 to 5 V
High = 15 V to UO

Digital outputs

U log 0 = 0 to 5 V
log 1 = 15 V to UO 3 V
Imax = 30 mA

Analogue inputs
Configuration as voltage input E1, E3 and E4
Range

U 10 V

Input resistance

Ri 100 k, > 10 M for input E3

Resolution

5 mV for range 10 V
2.5 mV for range 0...10

Non-linearity

< 10 mV

Configuration as current input (E2 only)


Range
Input resistance
Current loss
Resolution
Reference voltage

I 4...20 mA
Ri 100
0.15 % (at 500 between pin b24, b8, b20 and 0 V)
I 5 A
U 10 V
Imax 30 mA

Residual ripple content

< 20 mV

Oscillator frequency

f 5.7 kHz

Scanning time for command value conditioning

t 2 ms

Serial interface

RS 232 (front panel), D-Sub socket

Type of connection

64-pin male connector, DIN 41612, form G

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side

7 TE

Permissible operating temperature range

0 to 50 C

Storage temperature range

20 to + 70

Weight

m 0.2 kg

Note:
Details regarding environment simulation testing in the fields of EMC (electromagnetic compatibility), climate and mechanical
stress, see RE 30126-U (declaration on environmental compatibility).

311
RE 30126/09.05

Hydraulics Bosch Rexroth AG

VT-VRPD-2

5/8

Pin assignment of male connector


Pin

Row z

Row b

Row d

M1+

Solenoid A+

n. c.

DI 1

Binary 1

M1

Solenoid A

n. c.

DI 2

Binary 2

n. c.

M2+

Solenoid B+

E3+

Ramp + (U)+

DI 3

Binary 4

n. c.

M2

Solenoid B

E3

Ramp + (U)

DI 4

Binary 8

n. c.

10

Shield

Shield

n. c.

DI 5

n. c.

n. c.

12

L 1O

LVDT supply +

n. c.

DI 6

Binary valid

n. c.

14

L 1I

LVDT signal

E1+

Comm. value (U) +

DI 7

n. c.

n. c.

16

L 1I+

LVDT signal

E1

Comm. value (U)

DI 8

n. c.

n. c.

18

L 1O+

LVDT supply

E4+

Ramp (U)+

DI 9

Enable

n. c.

20

System gnd

System ground

E4

Ramp (U)

DO 1

Solenoid A active

n. c.

22

DO 3

System deviation window

E2+

Comm. value (I) +

OK

OK outptu

n. c.

24

DO 4

Freely configurable

E2

Comm. value (I)

Data +

n. c.

n. c.

26

DO 5

Freely configurable

AO 3

Act. valve value 10V DO 2

Solenoid B active

n. c.

28

DO 6

Freely configurable

AGND Analogue G ND

Data

n. c.

n. c.

30

UB

Supply voltage

REF

10 V

AO 1

Valve comm. value

n. c.

32

LO

Weight

REF+

+10 V

AO 2

n. c.

n. c.

Pin assignment of D-SUB socket on the front panel

1
6
Receive data (RS 232)
Send data (RS 232)
GND
9
5

RS 232

Row f
DO 7

n. c.

01

312
6/8

Bosch Rexroth AG

Hydraulics

VT-VRPD-2

RE 30126/09.05

Unit dimensions (nominal dimensions in mm)

Rexroth

O1

I2

O2

I3

O3

I4

O4

I5

O5

I6

O6

I7

O7

122

I1

100
89

3HE (128,4)

OK

RS232

X1 X2

VRPD-2

8TE (40,3)

165
195,5

Engineering / maintenance notes / supplementary information


The amplifier card may only be plugged or withdrawn when disconnected from the power supply!
Do not use plugs with free-wheeling diodes or LED indicator lamps for connecting the solenoids!
Measurements on the card may only be taken using instruments Ri > 100 k!
Use relays with gold-plated contacts for passing on command values (small voltages, small currents)!
Route command value cables separately and always shield them; connect shield to connection z10 on the card side and leave
the other end open (risk of earth loops)!
For solenoid cables up to 50 m length, use cable type LiYCY 1.5 mm2. In the case of greater lengths, please consult us!
Recommendation:
Also shield solenoid cables!
Use highly flexible Cu cables (min. 2.5 mm2) for connecting the system ground!
The system ground is an integral part of EMC protection of the amplifier card. It is intended to discharge interference that
comes via the data and supply cables. This is only possible, when the system ground itself does not inject interference into the
command value card.
The distance to aerial lines, radio sources and radar equipment must be at least 1 m!
Do not lay solenoid and signal cables near power cables!
Due to the charging current of the smoothing capacitor on the card, back-up fuses must have slow-blowing characteristics!
Caution:
Note:

When the differential input is used, both inputs must always be switched on or off simultaneously.
Electrical signals brought out via control electronics (e.g. signal OK) must not be used for switching safety-relevant machine functions!
(See also European standard safety requirements for fluid power systems and components - hydraulics,
EN 982)

313
RE 30126/09.05

VT-VRPD-2

Hydraulics Bosch Rexroth AG

7/8

Notes

01

314
8/8

Bosch Rexroth AG

Hydraulics

VT-VRPD-2

RE 30126/09.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

315

Analog Command Value Card

RE 30255/06.05
Replaces: 11.02

1/8

Type VT-SWKA-1

Series 1X

H6538_d

Table of contents
Contents
Features

Features
Page
1 and 2

Ordering code

Functional description

Block circuit diagram / pin allocation

Technical data

5 and 6

Indicator / adjustment elements

Unit dimensions

Engineering / Maintenance notes / Supplementary information 8

Analog command value card (without power part) for


controlling valves with integral electronics
For controlling valves without integral electronics, a
suitable additional amplifier is required.
Suitable for generating, combining and normalizing command
value signals
Configuration and parameterization of the command value card
by means of potentiometers
Command value inputs:
Differential input 10 V
4 callable command value inputs 10 V
Current input 4 to 20 mA
(standard 0 to 100 %; can be changed over 100 %)
Control variable output:
Voltage 10 V
Current 4 to 20 mA (standard 0 to 100 %; can be changed
over 100 %)
Inversion of internal command value signal using 24V input or
jumper
Ramp time selection by quadrant recognition (24V input) or
ramp time call-ups (24V inputs)

Information on available spare parts:


www.boschrexroth.com/spc

Ramp time range can be changed over by means of jumpers

316
2/8

Bosch Rexroth AG

Hydraulics

VT-SWKA-1

RE 30255/06.05

Features (continued)
Further information:

Characteristic curve correction by means of separately


adjustable step-change heights and maximum values
Enable input

VT-SWKA-1 product description and commissioning


instructions, see RE 30255-B

Output signal ramp ready as auxiliary process variable

Suitable card holders:

Output signal ready for operation

19 rack types VT 19101, VT 19102, VT 19103 and VT 19110


(see RE 29768)

Switchable measuring socket

Closed card holder VT 12302 (see RE 30103) with blind


plate insert 4TE/3HE (material no. R900021004)

Reverse voltage protection for voltage supply

Open card holder VT 3002-2X/48 (see RE 29928)


For control cabinet installation only!
Suitable power supply units:
Type VT-NE30-1X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 70 VA
Type VT-NE31-1X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 7 VA
Type VT-NE32-1X, see RE 29929
Compact power supply unit 115/230 VAC 24 VDC, 60
VA (smoothed) and 24 VDC, 25 VA (regulated)

Ordering code

VT-SWKA-1 1X V0

*
Further details in plain text

Analog command value card


Series 10 to 19
(10 to 19: unchanged technical data and pin allocation)

0=

= 1X
V0 =

Basic version
Basic version

317
RE 30255/06.05

VT-SWKA-1

Hydraulics Bosch Rexroth AG

3/8

Functional description
General
The command value card is designed as printed circuit board
in Euro-format 100 x 160 mm and is suitable for installation in
a rack. A power supply unit [1] provides the internally required
positive and negative supply voltages. As soon as the power
supply unit is in operation and no error is present, the green
LED on the front panel lights up and the ready for operation
signal is set.
Current input [3]
There is no changeover between current and voltage input.
Both inputs are permanently available (see terminal allocation).
The input signals are internally normalized and added. The zero
point and the range of values of the current input can be
changed over by means of jumper J5.
Command value call-ups [4]
Four command value signals, w1 to w4, can be called up.
External command value voltages (command values 1 to 4)
are preselected either directly via the regulated voltage inputs
+10 V and 10 V or via external potentiometers. If the
command value inputs are connected directly to the regulated
voltages, the command values are adjusted by means of
potentiometers w1 to w4. If external potentiometers are
used, the internal potentiometers act as attenuators or limiters.
Only one call-up is possible at a time. If several call-ups are selected simultaneously, call-up 1 has lowest priority, call-up 4
highest priority.

Ramp generator [9]


The ramp generator limits the increase of the control variable.
Downstream step-functions and amplitude attenuators do not
shorten or extend the ramp time.
Jumper J2 can be used to set the ramp time to minimum
(< 2 ms) (ramp off).
External ramp time adjustment
The internally set ramp time can be extended by means of an
external potentiometer. The setting can be verified with the help
of the measuring socket. In the case of a cable break, the
internal presetting will be validated automatically.
Ramp status signal [11]
The status signal ramp ready indicates that the control
variable has reached the requested final value. This signal (24V
output) facilitates the synchronization of higher-level sequence
controls with the valve function or the controlled hydraulic
function.
Characteristic curve generator [12]
The adjustable characteristic curve generator can be used to
adjust step-change heights and maximum values separately for
positive and negative signals according to the hydraulic
requirements. The actual characteristic curve shape through
the zero point is not step-like, but linear.
Amplitude limiter [13]

A yellow LED on the front panel indicates, which call-up is


active.

The control variables (current output and voltage output) are


limited to approx. 110 % of the nominal range.

Command value inversion [7]

Fault recognition [14]

The command value that is generated internally from input


signals, command value call-ups and zero point offset signals
can be inverted by means of an external signal or jumper J1. An
LED (1) on the front panel signals whether an external
inversion signal is applied.

This features monitors internal operating voltages, voltage


outputs and, if jumper J7 (1-2) is plugged, the current output
for cable break. When no fault is present, the green ready for
operation LED lights up and the output ready for operation
is set to 24 V (operating voltage).

Enable function [8]

Measuring points [15]

The enable function cuts the enable signal of the ramp generator in or out. When the enable is cut in or out, the control variable changes at any command value according to the set ramp
time. This prevents a controlled valve from opening or closing
suddenly. If an error signal is present, the input signal of the
ramp generator is also set to 0 %. An LED on the front panel
signals that an enable signal is applied.

A measuring socket is provided on the front panel to allow the


verification of the settings of command value call-ups, ramp times and further, internal signals. The measuring points can be
selected using the measuring point selector switch that is also
provided on the front panel. The signal of the measuring socket
is also connected to the blade connector (b26).
[ ] = Reference to the block circuit diagram on page 4

01

b14
+
b16

b22
+
b24

d24
d28

9 Ramp generator
10 Ramp time selection logic

5 Zero point adjustment

100 F

Zw 5

4 Command value selection logic

UL

J1

8 Enable function

w1

t5

7 Command value inversion

t4

3 Current input

L0

w2

t3

2 Differential amplifier

w3

t2

6 Command value summation

0V

z32

z30

b10
d18

w4

J5

2
u

t1

10

t
t4

+/

M0
5 V
7,5 V
15 V

+15 V
+7,5 V

Gw+

15 Measuring point changeover

14 Fault recognition

13 Amplitude limiter

1)

F
DE 0

0 12 3 4 5 6 7 8 9A B C D E F

1)

12

Measuring points

J4

S+

Gw

UL

14

J7

UL

+10 V/25 mA

Ready for
operation

z20

System ground

b28 M0

b26 Measuring signal

b30 10 V/25 mA

b32

d22

4 bis 20 mA

d32 Control variable

0 to 10 V

For explanations regarding the jumpers as


well as the position and assignment of indicator and adjustment elements, see page 7

Measuring points 8 and 9


are not assigned

15

13

J6

d30 Control variable

d26 Ramp ready

VT-SWKA-1

12 Characteristic curve generator

11 Ramp status function

DC

DC

t3

t2

J2, J3

t1

max

UP/DOWN

4Q

11

Hydraulics

1 Power supply unit

voltage

Operating 24 V

Enable

Inversion

Command value
call-ups

d2
1
d4
2
d6
3
d8
4

Command value 1 b2

Command value 2 b4

Command value 4 b8
Command value 3 b6

Command value 6:
4 to 20 mA

Command value 5:
10 V to +10 V

Ramp time
external

Ramp call-ups

d10
1
d12
2
d14
3
d16
4
+15 V

1234
7
56 89

Quadrant operation b20

Bosch Rexroth AG

ABC

4/8

318
RE 30255/06.05

Block circuit diagram / pin allocation

319
RE 30255/06.05

Hydraulics Bosch Rexroth AG

VT-SWKA-1

5/8

Technical data (for applications outside these parameters, please consult us!)

Operating voltage

UB 24 VDC +40 % 20 %

Operating range:
Upper limit value

UB(t)max 35 V

Lower limit value

UB(t)min 18 V

Power requirement
Current consumption
Fuse

PS < 7 VA
I < 0.3 A
Thermal overload protection; auto-activating when triggered

Inputs:
Analog
command values 1 to 4 (potentiometer inputs)

Ue 0 to 10 V; Re = 100 k (reference is M0)

command value 5 (differential input)

Ue 0 to 10 V; Re > 50 k

command value 6 (current input)


ramp time external

Ie 4 to 20 mA; load RB = 100 (zero point can be changed over)


Ue 0 to +10 V; Re = 10 k (internally raised to +15 V; reference is M0)

Digital
command value call-ups

U 8.5 V to UB call-up activated


U 0 to 6.5 V no call-up

ramp call-ups

U 8.5 V to UB call-up activated


U 0 to 6.5 V no call-up

quadrant recognition

U 8.5 V to UB ON
U 0 to 6.5 V OFF

command value inversion

U 8.5 V to UB ON
U 0 to 6.5 V OFF

enable

U 8.5 V to UB ON
U 0 to 6.5 V OFF

Adjustment ranges:
Zero point adjustment (potentiometer Zw)

30 %

Command values (potentiometers w1 to w4)

0 to 110 %

Ramp times (potentiometers t1 to t5)

20 ms to 5 s (can be changed over using J3)

Step-change height (potentiometers S+ and S)

0 % to 50 % (step-change height reached at ca. 2 % command value injection)

Amplitude attenuator (potentiometers G+ and G)

0 % to 110 % (valid when step-change height is set to 0 %)

01

320
6/8

Bosch Rexroth AG

Hydraulics

VT-SWKA-1

RE 30255/06.05

Technical data
Outputs:
Analog signals
control variable

voltage
current

measuring signal

U 10 V 2 %; Imax = 2 mA
I 4 mA to 20 mA 2 %; RB max = 500 (zero point can be changed over)
U 10 V 2 %; Imax = 2 mA

Digital signals
ramp ready

U > 16 V; 50 mA

ready

U < 1 V; Ri = 10 k ramp active


ready for operation
Regulated voltages

U > 16 V; 50 mA (in the event of a fault: U < 1 V; Ri = 10 k)


U 10 V 2 %; 25 mA

Measuring sockets
measuring signal v
(depending on position of measuring point selector switch)

U 10 V 2 %; Imax = 2 mA

Type of connection

48-pin blade connector, DIN 41612, form F

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side

3 TE

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 C to +85 C

Weight

m 0.15 kg

Note:
For details regarding environment simulation tests in the fields of
EMC (electromagnetic compatibility), climate and mechanical stress,
see RE 30255-U (declaration on environmental compatibilty).

321
RE 30255/06.05

Hydraulics Bosch Rexroth AG

VT-SWKA-1

7/8

Indicator / adjustment elements


J5 current input

1-2

2-3

4 mA
0%=

12 mA
0%=

J1 inversion

1-2

2-3

inverting

not inverting

J4 Step function

1-2

2-3

OFF

ON

No function!
(Reserve)

Do not change!
(Ramp time symmetry)
Rexroth

-14Q T

J5
4
12

F 01

23
456

BCDE

Zw
w1
w2
w3
w4
t1
t2
t3
t4

1
1

J8

J1
1

J3 J2

G+

S+

01
12
4

J6

J7

J4

t5
v0

vF

789A

SWKA
Do not change!
(Internal reference voltage)
Measuring point selector
switch
LED lamps:
Readiness for operation (green)
Enable (yellow)
External inversion
1
Quadrant recognition
4Q
Reserved
T
Potentiometers (some with LED lamp):
Zero point adjustment
Zw
Command value 1
w1
Command value 2
w2
Command value 3
w3
Command value 4
w4
Ramp time 1
t1
Ramp time 2
t2
Ramp time 3
t3
Ramp time 4
t4
Ramp time 5
t5
Cannot be adjusted on the front panel:
Amplitude attenuator for positive commandvalues
G+
Amplitude attenuator for negative command values
G
Step-change height for positive direction
S+
Step-change height for negative direction
S
Measuring sockets:
Measuring signal
v

Measurement zero

J6 current output

1-2

2-3

1-2

2-3

ON

OFF

1-2

2-3

OFF

ON

Ten-fold

Single

4 mA
0%=
12 mA
0%=
J7 cable break
monitor

J2 Ramp function

J3 Ramp time

Connection made

Connection broken
Factory setting of jumpers

For further information and notes, see product description


and commissioning instructions RE 30255-B!

322
8/8

Bosch Rexroth AG

Hydraulics

RE 30255/06.05

VT-SWKA-1

Unit dimensions (Dimensions in mm)

Rexroth

89

3HE (128,4)

Zw
w1
w2
w3
w4
t1
t2
t3
t4

100

-14Q T

23
456

BCDE

t5
F 01

v0

vF

789A

SWKA

4TE (20)

2
7

165
182

Engineering / Maintenance notes / Supplementary information


The command value card may only be withdrawn or plugged in when disconnected from the power supply!
Never install cables near power cables!
The distance to antenna cables, radio equipment and radar systems must be at least 1 m!
Use relays with gold-plated contacts for switching command values (small voltages, small currents)!
Always shield command value cables; connect shield to protective earth (PE) on the card side!
Note:
When using the differential input, both inputs must always be switched on or off simultaneously!
Electrical signals processed by control electronics (e.g. signal ready for operation) must not
be used for activating safety-relevant machine functions!
(See European standard Safety requirements for fluid power systems and components hydraulics, EN 982)

For further information, see product description and commissioning instructions VT-SWKA-1 (RE 30255-B).

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

323

RE 30282/01.05

Setpoint signal card

Type VT-SWKA1-5

Unit series 1X

Overview of contents
Contents
Features

Features
Page
1

Ordering data and scope of delivery

Preferred types

Front panel

Block diagram with terminal assignment

Application

Technical data

Unit dimensions

Used for setpoint generation


4 internal, variable setpoints
Setpoint recall using digital signals
2 signal inputs for inversion

1/6

324
2/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWKA1-5

RE 30282/01.05

Ordering data and scope of delivery


VTSWKA151X/V0/ 0
0=
Setpoint signal card
V0 =
1X =

Preferred types (available at short notice)


Type

Material No.

VT SWKA1 5 1X / V0 / 0

0 811 405 093

Front panel

No optional extras
Customized version
Catalog version
Unit series
Unit series 10 to 19

325
RE 30282/01.05

Type VT-SWKA1-5

Industrial Hydraulics

Bosch Rexroth AG

3/6

Block diagram with terminal assignment

01

326
4/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWKA1-5

RE 30282/01.05

Application
Two-channel setpoint card for the preparation and recall of four
internal signal voltages (Uset = 0 10 V) per channel.

Two differential inputs, UE1 (Channel 1) and UE2 (Channel 2),


allow additional external setpoints 0 to 10 V to be entered.

The setpoint signal cards output signals UA1 (Channel 1) and


UA2 (Channel 2) are generally used for controlling a proportional amplifier.

The output signal UA1 (Channel 1) or UA2 (Channel 2) can be


inverted by an external input signal INV1 or INV2; i.e. positive
setpoints UE1 and UE2 or internal setpoints P1 to P8 result in
a negative output UA1 or UA2.
Green LEDs on the front panel indicate an inverted output
signal.

Eight setpoints of 0 to +10 V can be selected by eight


internal potentiometers divided between two separate
channels:
P1 to P4 (Channel 1)
P5 to P8 (Channel 2).
Individual setpoints are recalled via the external enable signals
(switching signals +24 V), which are assigned to the potentiometers:
Setpoint 11 to Setpoint 14 (Channel 1)
Setpoint 21 to Setpoint 24 (Channel 2).
The selected recall is signaled by yellow LEDs:
LED 1 to LED 8.

Setpoint signal linkage.


If more than four internal setpoints are required, up to eight
setpoints can be processed in Channel 1 by supplying output
UA2 (Channel 2).

327
RE 30282/01.05

Type VT-SWKA1-5

Industrial Hydraulics

Bosch Rexroth AG

5/6

Technical data
Specifications
PCB format

(100 x 160 x approx. 35) mm (W x L x H), Europe format with front panel
(7 modular spacings)

Plug-in connection

Connector DIN 41612 F32

Ambient temperature

0 C ... +70 C, storage temperature min. 20 C, max. +70 C

Power supply
UB at z2b2

24 V DC nominal, 21 ... 28 V unfiltered


(rectified AC voltage)

Current rating

150 mA max.

Signal preparation

8 trimming potentiometers for 0 ... 10 V


Negative output signals via external command INV1 (b8) or INV2 (b26)

Signal recall
z2 ... z8/z26 ... z32

8 signal inputs +24 V (max. 40 V DC) Ri = 2 k


P1 ... P4 or P5 ... P8 individual or cumulative

Display

Yellow LED for potentiometer being recalled


Green LED for true output signal and inverted output signal

Combination
P1 ... P8 via Channel 1

Bridge z24z18: P1 ... P4 +P5 ... P8


Brcke z24z16: P1 ... P4 P5 ... P8

01

328
6/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWKA1-5

RE 30282/01.05

Unit dimensions (nominal dimensions in mm)

Connector DIN 41612 F 32

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

Bosch Rexroth AG reserves all rights, including industrial property rights.


We reserve all rights of disposal, such as copying and passing on to third
parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered
that our products are subject to a natural process of wear and aging.

329

Setpoint and voltage-controlled


ramp generator

RE 30281/01.05

Type VT-SWKA3-5

Unit series 1X

Overview of contents
Contents
Features

Features
Page
1

Ordering data and scope of delivery

Preferred types

Front panel

Block diagram with terminal assignment

Planning notes

Technical data

Unit dimensions

Used for setpoint generation


4 internal, variable setpoints
Setpoint recall using digital signals
Inputs for external setpoint entry
Used for ramp generation
Choice of two ramp time ranges
t1 = 0,1 ... 3 s, t2 = 2 ... 60 s
Choice of external or internal ramp control
Automatic quadrant recognition

1/6

330
2/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWKA3-5

RE 30281/01.05

Ordering data and scope of delivery


VTSWKA351X/V0/ 0
Setpoint and voltage-controlled
ramp generator

0=
V0 =
1X =

Preferred types (available at short notice)


Type

Material No.

VT SWKA3 5 1X / V0 / 0

0 811 405 116

Front panel

No optional extras
Customized version
Catalog version
Unit series
Unit series 10 to 19

331
RE 30281/01.05

Type VT-SWKA3-5

Industrial Hydraulics

Bosch Rexroth AG

3/6

Block diagram with terminal assignment

01

332
4/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWKA3-5

RE 30281/01.05

Planning notes
Application
1. Preparation and recall of internal and external signal voltages
UE = 0 ... 10 V.
2. Generation of signal voltage ramps t = 0.1 ... 60 s.
Ramp time adjustable in proportion to control voltage
UT = 0 ... +10 V,
defined externally (linear adjustment curve).
Setpoint generation
4 internal, variable setpoints: adjustable via potentiometers
P1 ... P4 on the front panel. Power supply from internal, stabilized voltage source z32 = +10 V or z30 = 10 V
Setpoint recall: via digital signals +24 V at terminals z24, z26,
z4 and z2 (P1, P2, P3, P4)
3 inputs for external setpoint entry: (0 V reference potential)
input voltage 0 ... 10 V at terminals b10, b12 and b18 (input
impedance Ri = 100 k)
1 input for external setpoint entry: (designed as differential
amplifier input) input voltage 0 ... 10 V at terminals b14 (signal) and b16 (ref. 0 V)
Input impedance Ri = 100 k.

Ramp generation
Choice of two ramp time ranges: t1 = 0.1 ... 3 s, t2 = 2 ... 60 s.
Adjustable using S1 on the front panel
Choice of external and internal ramp control with high level
digital signal (+24 V) at terminal z16 (+24 V) external ramp
time control, low level signal (0 V) or open input internal
ramp time control
Internal linear adjustment of ramp time via potentiometer P5
(acceleration = ) and P6 (braking = )
External linear adjustment of ramp time via terminal z18
(acceleration = ) and z12 (braking = ) Control voltage
UT = 0 ... +10 V proportional to the ramp time Reference zero
for UT = z10
Ramps with automatic quadrant recognition for positive and
negative setpoints
Ramp OFF control with digital signal (+24 V) at z14, high
level signal (+24 V) Ramp OFF, low level signal (0 V) or
open input ramp process curve.
Signal outputs
Main output (summing output setpoints) b26, UA = 0 ... 10 V
Test output for test purposes b24, UTest = 0 ... 10 V summing
setpoint without ramp control (input signal for ramp generator)
Signal ground b28/z28
Output load: RL 10 k.

333
RE 30281/01.05

Type VT-SWKA3-5

Industrial Hydraulics

Bosch Rexroth AG

5/6

Technical data
Specifications
PCB format

(100 x 160 x approx. 35) mm (W x L x H), Europe format with front panel
(7 modular spacings)

Plug-in connection

Connector DIN 41612 F32

Ambient temperature

0 C ... +70 C, storage temperature min. 20 C, max. +70 C

Power supply
UB at b32
and 0 V at b2

24 V DC nominal, battery voltage 21 ... 40 V


Rectified AC voltage Ueff = 21 ... 28 V
(single phase, full-wave rectification)

Current rating

350 mA max.

Setpoints

4 internal, variable setpoints (+10 V ... 0 V or 10 V ... 0 V)


3 inputs for external setpoint entry (10 V)
1 input for external setpoint (10 V) differential input

Ramps

2 ramp time ranges (0.1 ... 3 s/2 ... 60 s)


Separate adjustment of acceleration and deceleration ramps
Ramp OFF command input
Possibility of external entry of voltage-controlled ramps

Outputs

Signal output (z20/b12), 10 V, load capacity 10 mA


Test output (b24) without ramp function, load capacity 10 mA

Digital inputs
(control inputs)

Signal voltage UE = +6 ... +40 V, UE nom = +24 V


High signal +6 V
Low signal +6 V
Input impedance Ri = 2 k (input current approx. 10 ... 15 mA)

Displays/signals

LED displays (yellow) for operational setpoints P1 ... P4


LED displays (green) for internal or external ramp time adjustment
LED display (yellow) for ramp deactivated T = 0
2 LED displays (green) for ramp output
a) LED UA = 0: LED lights up when ramp output = 0
b) LED UA = UE: LED lights up when ramp output = sum of setpoint inputs
2 LED operating status displays: LED (green) operating voltage UB = On
LED (red) insufficient operating voltage
Digital output b4 = +24 V, output load RL 10 k
Signal (high level): ramp output signal has achieved setpoint input signal level
Digital output b30 = +24 V, output load RL 10 k
Signal (high level): ramp output signal has reached 0 V

01

334
6/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWKA3-5

RE 30281/01.05

Unit dimensions (nominal dimensions in mm)

Connector DIN 41612 F 32

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

Bosch Rexroth AG reserves all rights, including industrial property rights.


We reserve all rights of disposal, such as copying and passing on to third
parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered
that our products are subject to a natural process of wear and aging.

335

RE 29902/07.05
Replaces: 02.03

Analogue command value module

1/6

Type VT-SWMA-1

Series 1X

H5999

Table of contents
Contents

Features
Page

Features

Ordering code, preferred types

Functional description

Block circuit diagram / pin assignment

Technical data

Terminal assignment

Unit dimensions

Engineering / maintenance notes / supplementary information 6

Suitable for controlling valves with integral electronics


Possibility of realising simple hydraulic functions via digital
controlling
Adjustment elements:
1 potentiometer for zero point adjustment
(command value offset)
1 potentiometer for command value attenuation
(for differential input)
4 potentiometers for command value preselection
5 potentiometers for ramp time adjustment
LED lamps:

Command value call-up (4 x)


Active ramp time (4 x)
Quadrant recognition
Polarity reversal
Power

Measuring sockets for command value and ramp time


Differential input
4 call-up possibilities each for command value and ramp time
Ramp generator with 5 ramp times; 4-quadrant recognition
Control signal output
Power supply unit without raised zero point
Without power part

336
2/6

Bosch Rexroth AG

Hydraulics

VT-SWMA-1

RE 29902/07.05

Ordering code
VT-SWMA-1

1X V0

Analogue command value module

Further details in clear text

Series 10 to 19
(10 to 19: unchanged technical data
and pin assignment)

= 1X

0=
V0 =

Basic version
Basic version

Functional description
General
The command value module is to be snapped onto top hat rails
to EN 60715. The electrical connection is made using screwtype terminals. The module is operated with 24V DC voltage.
A power supply unit [1] provides the internally required positive
and negative supply voltages. The green LED (power) lights up
as soon as the power supply unit is in operation.

Ramp time call-ups [11]


When quadrant recognition is not activated, a separate ramp
time t1 to t4 is assigned to each command value call-up
w1 to w4.
As long as a signal is being changed, the LED assigned to the
current ramp time is alight.

Internal command value


The internal command value is generated from the external
command value signal applied to differential input [2], a called
up signal and an offset signal (zero point potentiometer Z
[3]).
The external command value signal can be changed from 0 %
to approx. 110 % by means of potentiometer G (amplitude attenuator [4]).
Command value call-ups
Call-up signals w1 to w4 [5] can also be adjusted between 0
% and 110 %. Call-up signals w1 and w2 have a positive, callup signals w3 and w4 a negative polarity. This allows the realisation of two forward and two reverse movements of the hydraulic drive without requiring any additional circuitry. For applications that require more than two signals of the same polarity,
command value inversion is provided [6]. If this is activated, for
example, together with call-up 3, call-up signal w3 also provides a positive control variable.
Only 1 call-up is possible at a time. If several call-ups are activated simultaneously, the following is valid: Call-up 1 has the
lowest priority, call-up 4 has the highest priority [7].
Quadrant recognition
When quadrant recognition [8] is activated, the electronics
automatically recognises the polarity [9] and any changes (up/
down) [10] in the control variable and assigns a ramp time to
the current signal state.
Ramp
time

As long as the signal is being changed, the LED assigned to


the current ramp is alight.

Polarity ofSignal changes


control output in direction of

t1

Maximalwert

t2

0%

t3

Maximalwert

t4

0%

0%

Maximum
value (+)

Maximum
0%
value (+)
Maximum
0%
value ()
Maximum
value ()

0%

Ramp time t5 [12]


If neither quadrant recognition nor a call-up is activated, ramp
time t5 is always valid. This ramp time can be used, among
others, for an emergency stop function. The valve can be
closed with the defined ramp time t5.
Ramp time adjustment
The current ramp time can be checked at measuring socket t
[13]. Ramp times t1 to t4 can be adjusted with the help of
the ramp time potentiometers. Through activation of a call-up
signal, ramp time signal t at the measuring socket is clearly assigned to one of the ramp times t1 to t4. t5 is assigned to
the ramp time signal at the measuring socket, if neither a callup nor quadrant recognition is activated. The adjustment range
of the ramp time is selected so that these can be set reproducibly (for details, see Technical data).
Output
The output signal of the ramp generator can be checked at
measuring socket w [14]. The downstream matching amplifier
[15] provides the control signal for the valve via output control
variable [16].
[ ]

= Cross-reference to block circuit diagram on page 3

Operating
voltage

0V

+U
+ U0B

Quadrant operation

Call-up command value 4

Call-up command value 3

Call-up command value 2

Call-up command value 1

12

11

Power supply unit

Differential amplifier

Summator with zero point


potentiometer

Amplitude attenuator

Call-up signals

DC

M0

15 V
+ Uref
Uref

+ 15 V
t2

11

t3

10 Recognition of changes in the


contol variable (up/down)

Quadrant recognition
Polarity recognition

Priority logic

Command value inversion

t1

t4

10

t5 12

13

15

14

+/ 9

15 Matching amplifier

14 Measuring socket internal command value

13 Measuring socket ramp time signal

12 Ramp time potentiometer t5

11 Ramp time call-ups

Ramp time selection logic

Inv

potential

8 Reference

variable

7 Control

VT-SWMA-1

Uref
w4

4-Q

Uref
w3

DC

+Uref

w2

L0

+Uref

w1

10

Reference potential 4

Command value 10 V

Differential input:

Command value inversion

RE 29902/07.05

337
Hydraulics Bosch Rexroth AG
3/6

Block circuit diagram / pin assignment

01

338
4/6

Bosch Rexroth AG

Hydraulics

VT-SWMA-1

RE 29902/07.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

Uo 24 VDC +40 % 10 %

Operating range:
Upper limit value

uo(t)max 35 V

Lower limit value

uo(t)min 18 V

Power consumption

PS 12 VA

Current consumption

Imax 0.5 A

Fuse

Thermal overload protection


(reactivation when temperature falls below threshold)

Inputs
Command value (differential input with attenuator)

Ui 0 to 10 V; Ri > 50 k

Quadrant operation 4-Q


active

U4-Q 8.5 V to 35 V; Ri > 50 k

inactive

U4-Q 0 to 6.5 V

Command value inversion Inv


active

UInv 8.5 V to 35 V; Ri > 50 k

inactive

UInv 0 to 6.5 V

Command value call-ups 1 to 4


active

U 8.5 V to 35 V; Ri > 50 k

inactive

U 0 to 6.5 V

Adjustment ranges:
Zero balancing (potentiometer Z)

30 %

Amplitude attenuator (potentiometer G)

0 % to ca. 110 %

Command values (potentiometers w1 to w4)

0 % to ca. 110 % (factory setting 100 %)

Ramp times (potentiometers t1 to t5)

20 ms to 5 s

Outputs:
Control variable
Measuring socket for control variable w
Measuring socket for ramp time t
Type of connection

U 0 to 10 V; 2 mA; RL > 5 k
Uw 0 to 10 V (+100 % = +10 V; 100 % = 10 V)
Ut 0,01 V to +10 V 0,01 V(tmax = ca. 10 s); 10 V(tmin = ca. 10 ms)
12 screw terminals

Type of mounting

Top hat rail TH 35/7.5 to EN 60715

Type of protection

IP 20 to EN 60529

Dimensions (W x H x D)

40 x 79 x 85,5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +85 C

Weight

m 0.3 kg

Note:
For details regarding environment simulation tests in the field
of EMC (electro-magnetic compatibility), climate and mechanical
stress, see RE 29902-U (declaration on environmental
compatibility).

339
RE 29902/07.05

5/6

Hydraulics Bosch Rexroth AG

VT-SWMA-1

Note on the adjustment and measurement of the ramp time


For adjusting the ramp time potentiometers we recommend that
4-quadrant recognition be switched off and call-ups be activated.

Value at measuring socket t

Ut in V

0,5

0,3

0,2

0,1

0,05

0,03

0,02

Current ramp time ( 20 %)

t in ms

20

33

50

100

200

333

500

1000

2000

3333

5000

The following is valid:

t=

100 V ms
Ut

Example:

Measured

Ut = 5 V

Results in

t=

100 V ms
= 20 ms
5V

Terminal assignment

+U0

Control variable
output

0V

Reference
potential

+U4-Q

Call-up command value 1

Reference
potential 4

10

Call-up command value 2

Ucomm

11

Call-up command value 3

+UInv

12

Call-up command value 4

Operating
voltage

Quadrant
operation

Differential
input
Command value inversion

Unit dimensions (Dimensions in mm)


Top hat rail TH 35-7.5
to EN 60715

7 8 9 10 11 12
REXROTH
VT-SWMA-1
4-Q Inv
w1
w2
w3
w4
G
t w Z

79

t1
t2
t3
t4
t5

1 2 3 4 5 6
85,5

40

Potentiometers (some with LED lamps):


t1 to t5
Ramp times
w1 to w4
Command value call-ups
G
Amplitude attenuator for
differential input
Z
Zero point balancing
LED lamps:
4-Q
Quadrant recognition
Inv
Inversion active
green
Ready for operation power
(no lettering)
Measuring sockets:
t
Current ramp time
w
Internal control variable

Reference potential / ground

01

340
6/6

Bosch Rexroth AG

Hydraulics

VT-SWMA-1

RE 29902/07.05

Engineering / maintenance notes / supplementary information


The amplifier module may only be unplugged when disconnected from the power supply!
Ensure a sufficient distance to aerial lines, radio sources and radar equipment (>> 1 m)!
Shield command value lines, do not lay near power cables!
Caution: When the differential input is used, both inputs must be activated or deactivated simultaneously!
Note:

Electrical signals (e.g. control variable) brought out via control electronics must not be used
for switching safety-relevant machines functions!
(See also the European standard Safety requirements for fluid power systems and components
hydraulics, EN 982)

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

341

RE 29903/06.05
Replaces: 02.03

Analogue command value module

1/6

Type VT-SWMAK-1

Series 1X

H5973_d

Table of contents
Contents

Features
Page

Suitable for controlling valves with integral electronics

Features

For valve spool overlap compensation

Ordering code

Functional description

Possibility of adjusting the maximum valve opening and the


hydraulic zero point; convenient correction of zero point shifts

Block circuit diagram

Output characteristic curve

Technical data

Unit dimensions

Terminal assignment

Engineering / maintenance notes

Adjustment recommendations

Adjustment elements:
1 potentiometer for zero point adjustment (command value
offset)
2 potentiometers for command value attenuation for positive
and negative signals
2 potentiometers for jump adjustment for positive and
negative signals
LED lamps:

Enable
Power

Measuring socket for command value


Differential input; enable input
Control signal output
Power supply unit without raised zero point
Without power part
Reverse voltage protection for voltage supply
Information on available spare parts:
www.boschrexroth.com/spc

342
2/6

Bosch Rexroth AG

Hydraulics

VT-SWMAK-1

RE 29903/06.05

Ordering code

VT-SWMAK-1

1X V0

*
Further details in clear text

Analogue command value module


Series 10 to 19
(10 to 19: unchanged technical data and pin assignment)

Basic version

= 1X

Basic version

Functional description
adjusted. The adjustable characteristic curve generator [3] can
be used to adjust the jump height and maximum values independently of each other for positive and negative signals in
accordance with the hydraulic requirements.

The command value module requires 24V DC voltage. A


power supply unit [7] provides the internally required positive
and negative supply voltage. As soon as the power supply unit
is in operation, the green LED (power) lights up. The control
signal can be cut in or out by applying a signal at the enable
input (connection 3). If no enable signal is applied, the control
signal is 0 % (with reference to the reference potential GND
of the command value).

The potentiometers S+ and S serve to compensate for


the valve overlap; the potentiometers G+ and G are used
for adjusting the maximum flow of the servo- or proportional
valve (see output characteristic curve and adjustment recommendation).

The summator [2] adds an offset, which can be adjusted by


means of potentiometer Z, to the externally provided command value. Thus, zero point drifts from the control side can be
compensated for and the hydraulic zero point can be exactly

The control signal has the same reference potential/GND as


the command value. In the case of fluctuations in the reference
potential, the summator [4] corrects the control signal as required.

Block circuit diagram

G+
S+
Command value: Ui = 10 V
Reference potential/GND

6
5

6
Enable UE

24 V
Operating
voltage
0V

+ 15 V
power

DC
2

DC

1 Differential input
2; 4 Summator
3 Characteristic curve generator

+ Uref
M0
Uref
15 V
5 Output amplifier
6 Trigger
7 Power supply unit

5
4 Control
signal

343
RE 29903/06.05

Hydraulics Bosch Rexroth AG

VT-SWMAK-1

3/6

Output characteristic curve


Points of inflection of characteristic curves:
w
w3

u4

u0

0%

w0

0%

u1

+2 % = +200 mV

w1

w1

0 % to +50 % (S+)

u2

u2

2 % = 200 mV

w2

0 % to 50 % (S)

u3

+100 % = +10 V

w3

w1 up to +110 % (G+)

u4

100 % = 10 V

w4

w2 up to 110 % (G)

u1
u0,w0

u3 u

w2
w4

0 V to +5 V

0 V to 5 V

w1 up to +11 V

w2 up to 11 V

The minimum value of w3 and w4 corresponds


to the setting of w1 and w2.

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 18 V

Power consumption

PC 1.2 VA

Current consumption

Imax 50 mA

Fuse

Electronic protection

Inputs:
Command value (differential input)

Ue 0 to 10 V; Re = 100 k
(common reference potential with control signal output)

Enable
active

UF > 8.5 V

inactive

UF < 6.5 V

Adjustment range:
Jump function

0 to 50 %; jump height achieved at Ucomm = 2 %


(can be adjusted separately for positive and negative signals)

Amplitude attenuator

0 % to 110 %; this is valid for a jump height setting = 0 %


(can be adjusted separately for positive and negative signals)

Balance

10 %

Outputs:
Actuating signal
Measuring socket for command value w

U 0 to 10 V
Uw 0 to 10 V (10 V = 100 %)

Type of connection

6 screw-type terminals

Type of mounting

Carrier rail NS 35/7.5 to DIN 50022

Type of protection

IP 20 to DIN 40050

Dimensions (W x H x D)

25 x 79 x 85.5 mm

Permissible operating temperature range

0 to +50 C

Storage temperature range

25 to +85 C

Weight

m 0.08 kg

01

344
4/6

Bosch Rexroth AG

Hydraulics

VT-SWMAK-1

RE 29903/06.05

Unit dimensions (Dimensions in mm)


Carrier rail TH 35/7,5
to EN 60715

4 5 6

G+

Amplitude attenuator for positive command values

REXROTH
VT-SWMAK

S+

Jump height for positive direction

Amplitude attenuator for negative command values

Jump height for negative direction

Balancing

Internal command value

Reference potential

79

G+
S+
G
S
Z

LED lamps:
1 2 3
25

85,5

green

power

yellow

enable

Terminal assignment

Operating
voltage

Control
signal output

+UO

0V

GND

Reference
potential

UE

Ui

Command
value input

Enable

Engineering / maintenance notes


The command value module may only be wired when disconnected from the power supply!
Do not lay lines near power cables!
The distance to aerial lines, radio equipment and radar systems must be at least 1 m!
Always connect the reference potential of the differential input GND to the earth of the control!

345
RE 29903/06.05

VT-SWMAK-1

Hydraulics Bosch Rexroth AG

5/6

Adjustment recommendations
With external command value feedforward:

Without external command value feedforward:

1. Apply operating voltage


Turn potentiometers S+ and S- to the left-hand limit
stop (Min)
Turn amplitude attenuators G+ and G- to the
righthand limit stop (Max)
Preselect command value 0 %
Apply enable signal

1. Apply operating voltage


Turn potentiometers S+ and S- to the left-hand limit
stop (Min)
Turn amplitude attenuators G+ and G- to the right-hand
limit stop (Max)
Preselect command value 0 % (input open or short-circuited)
Apply enable signal

2. Zero point adjustment


Attention! Terminal 5 is the reference potential for the command value input and the actuating signal output and must
be connected to 0 V (earth) at the control.
Set 0 V at measuring socket w using potentiometer Z

2. Step height adjustment


Set an internal command value of +2 % using potentiometer Z the measuring socket signal is now 0.2 V
Adjust the positive jump height using potentiometer S+;
check the control variable at measuring socket w
(10 V = 100 %)
Set an internal command value of 2 % using zero point
potentiometer Z
the measuring socket signal is now 0.2 V
Adjust the negative jump height using potentiometer S-;
check the control variable at measuring socket w
(10 V = 100 %)

3. Jump height adjustment


Preselect command value +2 %
the measuring socket signal is now approx. 0.19 V to 0.23 V
Adjust the positive jump height using potentiometer S+;
check the control variable at measuring socket w
(10 V = 100 %)
Preselect command value 2 %
the measuring socket signal is approx. 0.19 V to 0.23 V
Adjust the negative jump height using potentiometer S-;
check the control variable at measuring socket w
(10 V = 100 %)
For an exact hydraulic adjustment, the valve and the
hydraulics must also be in operation. The jump height must
be adjusted according to the required min. drive speed
(creep speed).
4. Maximum value adjustment
Preselect command value +100 %
the measuring socket signal is now approx. 10 V to 11 V
Set the positive max. control variable using potentiometer
G+; check the control variable at measuring socket w
(10 V = 100 %)
Preselect command value 100 %.
the measuring socket signal is now approx. 10 V to 11 V
Set the negative max. control variable using potentiometer
G-; check the control variable at measuring socket w
(10 V = 100 %)

3. Zero point adjustment


Set 0 V at measuring socket w with the help of potentiometer Z
4. Maximum value adjustment
Only possible with external command value feedforward

01

346
6/6

Bosch Rexroth AG

Hydraulics

VT-SWMAK-1

RE 29903/06.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

347

RE 30284/01.05

Current/voltage signal
transformer module

Type VT-SWMA1-5

Unit series 1X

Overview of contents
Contents

Features
Page

Features

Ordering data and scope of delivery

Preferred types

Front panel

Block diagram with terminal assignment

Technical data

Unit dimensions

Module for converting 0...4...20 mA


to 0...10 V
3 usable signal outputs
1st output 0 ... 20 mA 0...+10 V
2nd output 4 ... 20 mA 0...+10 V
3rd output 4...12...20 mA 0...10 V

1/4

348
2/4

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA1-5

RE 30284/01.05

Ordering data and scope of delivery


VTSWMA151X/V0/ 0
Current/voltage signal
transformer module

0=
V0 =
1X =

Preferred types (available at short notice)


Type

Material No.

VT SWMA1 5 1X / V0 / 0

0 811 405 105

Front panel

No optional extras
Customized version
Catalog version
Unit series
Unit series 10 to 19

349
RE 30284/01.05

Type VT-SWMA1-5

Industrial Hydraulics

Bosch Rexroth AG

3/4

Block diagram with terminal assignment

01

UAUAUA
UA1: 0 ... +10 V
UA2: 0 ... +10 V
UA3: 0 ... 10 V

Technical data
Specifications
Format/design

(86 x 110 x 95) mm per module

Fastening/connection

DIN rail/connector with screw terminals

Temperature range

0...70 C; storage: 20...+70 C

Power supply

UB = 24 Vnom, batt.: 21 ... 40 V DC


Single-phase full wave: 21 ... 28 V DCeff

Current rating

approx. 0.1 A

Signal input 0...20 mA

Differential amplifier with shunt 200

Signal outputs: (max. 10 k load)

UA1: 0...+10 V (0...20 mA)


UA2: 0...+10 V (4...20 mA)
UA3: 0...10 V (4...12...20 mA)

Logic output term. 8


IE 3 mA

24 V DCnom 0 V, 24 V 0 V,
max. load capacity 50 mA

//
//
//
//

IEIEIEIE
0 ... 20 mA
4 ... 20 mA
4 ... 12 ... 20 mA

350
4/4

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA1-5

RE 30284/01.05

Unit dimensions (nominal dimensions in mm)

Wall mounting

Rail mounting

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

I/U-mA/V
86 x 110 x 95

DIN rail mounting (snap-in)

Wall mounting

Supplied loose

Bosch Rexroth AG reserves all rights, including industrial property rights.


We reserve all rights of disposal, such as copying and passing on to third
parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered
that our products are subject to a natural process of wear and aging.

351

RE 30283/01.05

Signal adjustment module

1/6

Type VT-SWMA2-5

Unit series 1X

Overview of contents
Contents
Features

Features
Page
1

Ordering data and scope of delivery

Preferred types

Front panel

Block diagram with terminal assignment

Signal interface module

Technical data

Unit dimensions

Signal adjustment module for servo solenoid valves with OBE


For linear curve adaptation, 40 % dual gain and 60 % dual gain
Signal adjustment for differential cylinders
Valve zero adjustment
Input signal V or mA

352
2/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA2-5

RE 30283/01.05

Ordering data and scope of delivery


VTSWMA251X/V0/ 0
0=
Signal adjustment module
V0 =
1X =

No optional extras
Customized version
Catalog version
Unit series
Unit series 10 to 19

Preferred types (available at short notice)


Type

Material No.

VT SWMA2 5 1X / V0 / 0

0 811 405 107

Front panel

Area adjustment

353
RE 30283/01.05

Type VT-SWMA2-5

Industrial Hydraulics

Bosch Rexroth AG

3/6

Block diagram with terminal assignment

* determines function UE or IE

Signal adapter

01

354
4/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA2-5

RE 30283/01.05

Signal (interface) module


For servo solenoid valves with on-board electronics:
Characteristic curve
Linear
Characteristic curve
Dual gain 60 %
Characteristic curve
Dual gain 40 %
Signal adjustment for differential cylinders
Valve zero adjustment
Test mode (man. 20 %)
Signal spread (lin. gain)
Input signal: V/mA

System layout
Valve characteristic

Controller
Curve adjustment
Area adjustment
Input signal mA or V
Test mode
Zero/gain

355
RE 30283/01.05

Type VT-SWMA2-5

Industrial Hydraulics

Bosch Rexroth AG

5/6

Technical data
Specifications
Format/design

(86 x 110 x 95) mm per module

Fastening/connection

DIN rail/connector + terminals

Temperature range

0 ... 70 C storage: 20 ... +70 C

Power supply

UB = 24 Vnom, batt.: 21 ... 40 V DC


Single-phase full wave: 21 ... 28 V DCeff

Current rating

approx. 0.1 A

Signal input
V or mA

UE 10 V, differential amplifier
Ri = 100 k
IE (0) ... 420 mA

Rsh = 200

Signal output 10 V

UA1 valves with linear characteristic curve


UA2 valves with dual gain (40 %)
UA3 valves with dual gain (60 %)

Miscellaneous

Test mode switches for man. control 20 % UA signal

01

356
6/6

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA2-5

RE 30283/01.05

Unit dimensions (nominal dimensions in mm)

Wall mounting

Rail mounting

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

SIGN-ADAP
86 x 110 x 95

DIN rail mounting (snap-in)

Wall mounting

Supplied loose

Bosch Rexroth AG reserves all rights, including industrial property rights.


We reserve all rights of disposal, such as copying and passing on to third
parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered
that our products are subject to a natural process of wear and aging.

357

RE 30262/06.05
Replaces: 07.99

Plug-in switching amplifier

1/4

Type VT-SSV-1

Series 2X

H 6138_d

Table of contents
Contents

Features
Page

Features

Ordering code

Block circuit diagram / pin allocation

Technical data

Unit dimensions

Project / maintenance instructions / additional information

Information on available spare parts:


www.boschrexroth.com/spc

Suitable for control of switching valves with direct current


solenoid operation through signals with low control power
Activation can carried out direct with the switch output signals
of an open loop control
Output with constant short circuit protection
Status indication of switching condition with LED

358
2/4

Bosch Rexroth AG

Hydraulics

Vt-SSV-1

RE 30262/06.05

Ordering code

VT-SSV-1

2X

*
Further details in clear text

Plug-in switching amplifier


Series 20 bis 29
(20 to 29: technical data and terminal connection unchanged)

= 2X

Block circuit diagram / pin allocation

1
U+

U+

IN

PE

IN

U+

2
GND
PE

Operating voltage on terminal U+ (24 V) and (GND)


Control voltage on terminal IN and (GND)
Protective ground on terminal PE

IN

PE

1 Connecting terminals
2 Electronic switch
3 LED for status indication
4 Solenoid contacts

359
RE 30262/06.05

Hydraulics Bosch Rexroth AG

VT-SSV-1

3/4

Technical Data (For application outside these parameters please consult us!)

Operating voltage

U+ 24 VDC +20 % 10 % (residual ripple < 15 %)

Output current

Imax 2 A (at 100 % duty)

Output voltage

Umax U+ 0.2 V (typical at 2 A)

Control voltage:
ON

UIN 10 to 35 VDC

OFF

UIN 0 to 6 VDC

Control current
Switching frequency

IIN 3 mA
fmax approx. 4 Hz

Cable connection:

Screw-type terminals max. 1.5 mm2

Fitting

Pg 11

External cable diameter

d 4 to max. 10 mm

Solenoid connection

Plug-in connector 2-pin + PE, EN 175301-803 (Z5L)

Connection cable (recommendation)

H05VV-F 4G1,5 (not included in delivery)

Permisible operating temperature range

25 to +70 C

Storage temperature range

25 to +70 C

Weight

m ca. 45 g

Note:
For details regarding environmental simulation test for the areas of EMC (electro-magnetic compatibility), climate and mechanical loading see RE 30 262-U (explanation regarding environmental compatibility).

01

360
4/4

Bosch Rexroth AG

Hydraulics

VT-SSV-1

RE 30262/06.05

Unit dimensions (dimensions in mm)


45
28

18

28

5,5

40

Project / maintenance instructions / additional information


The amplifier is integrated into a plug-in connector Z5L to EN 175301-803 with transparent cover. For the operation a terminal
lead with 3 wires is necessary. With a lead with four wires the protective conductor can also be connected.
Cable recommendation: H05VV-F 4G1,5
On mounting the housing can be rotated by 90 steps.
When overloading or short circuit occurs the output is switched off. Before switching back on the control signal UIN must be
switched to OFF ( 6 V).
The switching off times may be doubled or trebled because of the limitation of the negative switching off voltage peak.

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

361
RE 00112-04

Hydraulics Bosch Rexroth AG

Control cards and units

Designation

Type

Series

Data
sheet no.

Digital multi-axis NC control

VT-MAC8

1X

30156

363

Digital axis control

VT-HNC100-1,
VT-HNC100-2

2X

30131

379

Analog position controller

VT-MACAS

1X

30050

391

Digital positioning card for positiondependent braking

VT-HACDB

1X

30144

397

Digital control system assembly HNC100-SEK


for the secondary control of axial piston units

SYHNC100-SEK

2X

30141

405

Digital command value and controller card

VT-HACD-1

1X

30143

413

dp/Q controller

VT-VACAF

1X

30136

425

p/Q controller

VT-VACAP

2X

30134

433

p/Q amplifier

VT-VARAP1

2X

30058

441

Page

01

02

04

05

06

362
Bosch Rexroth AG

Hydraulics

RE 00112-04

363

Digital multi-axis NC control

Type VT-MAC8

Component series 1X

Table of contents
Contents

Page

Features

System overview

Ordering code for system

Software engineering

Overview of controller functions

4 and 5

NC interpreter

Programming language ECL-Win

Technical data
Pin assignment of master card
Pin assignment of slave card
Unit dimensions

Information on available spare parts:


www.boschrexroth.com/spc

7 and 8
9, 10 and 11
12
13, 14 and 15

RE 30156/04.05

1/16

364
2/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

RE 30156/04.05

Features
The MAC8 is a digital Rexroth multi-axis NC control of modular
design. It consists of a master card with no, 2 or 4 axis controllers and can be extended as required with up to seven slave
cards for four axes each. It is therefore the ideal solution for
complex control tasks with up to 32 interpolatable axes. Further MAC8s can be connected via local Ethernet. The MAC8
communicates via field bus (Profibus DP or CAN) or via Ethernet with the higher-level PLC machine control. It is provided
with special hydraulic closed-loop control characteristics and
can control movements of the machine or machine parts on its
own and therefore assumes PLC functions. Sensors and actuators can also be evaluated and controlled via CAN bus.

Interfacing / visualisation
By means of OPC server
By means of Active X elements
Interfaces: RS 485 or Ethernet
Programming
Use programming by means of a PC
Comprehensive diagnosis and debugging tools
Comfortable data management on a PC
High-level language-oriented
32 NC programs that can be executed in parallel

Fields of application:

High processing speed due to compiled programs

Presses (tube forming, metal / ceramic, powder, plastic,


deep drawing, glass presses, press brakes, die cushion
controls, IHF (internal high pressure forming, etc.)
Materials handling (container cranes, balance cranes,
train/truck lifts, belt drive, etc.)
Steelworks and rolling mill technology (continuous casters,
curved casting machines, mould oscillation, roll stands, 3-roll
bending machines, turning cooling beds, flying shears, ladle
cars, moulding plant, etc.)
Testing technology (weld testing machine, shock absorber
test bench, tube testing press, etc.)
Special machinery (coal distributors, thick sheet turning
equipment, engine turning system, etc.)

Fast integer and real arithmetic


Exponential and angle functions
Hydraulic axes
Measuring system Incremental or absolute (SSI)
Analogue 10 V and 4 to 20 mA
10 mA and 20 mA
Control output

Analogue 10 V and 4 to 20 mA
10 mA and 20 mA

Closed-loop control
Following controller

Process interfacing

State controller

32 digital inputs, 24 digital outputs, Profibus DP,


CAN open, TCP-IP

Position-dependent braking
Synchronisation controller for up to 32 axes (various variants)
Pressure/force controller

System overview
Profibus DP / CAN / Ethernet
Visualisation /
diagnosis

PLC / process control


level

Local Ethernet
Ethernet / RS422
CAN bus
Sensors
Up to 32
drives
Actuators

Up to 32
drives

365
RE 30156/04.05

Industrial Hydraulics Bosch Rexroth AG

VT-MAC8

3/16

Ordering code for system


VT-MAC 8 1X S
System with
1 slot
5 slots
8 slots

AX4

=1
=5
=8

Bus variant
No field bus
Profibus DP slave interface module

*
Further details in clear text
4 axis slaves
Number

0 to 7 =
= A
= P

Master
Without axis module, with RS485
2-axis version, with RS 485
4-axis version

1=
2=
4=

Selection aid
Part of

Analogue In

ordering code

RS 232

CAN Open

Profibus DP

Analogue I/O

Encoder plug

2X

4X

RS 485

AM 1

AM 2

AM 4

PM 1

PM 2

2X

PM 4

4X

Components

02
Material no.

Type

Designation

R901075726

VT-MAC8-1X/K-AM1

Master card without axis controller

R901075728

VT-MAC8-1X/K-AM2

Master card with 2 axis controllers

R901075730

VT-MAC8-1X/K-AM4

Master card with 4 axis controllers

R901075732

VT-MAC8-1X/K-PM1

Master card with Profibus DP, without axis controller

R901075734

VT-MAC8-1X/K-PM2

Master card with Profibus DP, with 2 axis controllers

R901075738

VT-MAC8-1X/K-PM4

Master card with Profibus DP, with 4 axis controllers

R901075752

VT-MAC8-1X/K-AX4

Salvekarte with 4 axis controllers

R901075757

VT-MAC8-1X/K-DUMMY

Blank location cover for one slot

R901075714

VT-MAC8-1X/K-RACK1

Blank rack with one slot (master card)

R901075722

VT-MAC8-1X/K-RACK5

Blank rack with 5 slots (1 master, 4 slaves)

R901075725

VT-MAC8-1X/K-RACK8

Blank rack with 8 slots (1 master, 7 slaves)

R901052075

Cable set MAC8/ABS/SF/3M

Cable for absolute value encoder SSI (X2), 3 metres, open end

R901052153

Cable set MAC8/INC/24V/SF3M

Cable for incremental encoder 24V (X2), 3 metres, open end

R901052152

Cable set MAC8/INC/5V/SF/3M

Cable for incremental encoder 5V (X2), 3 metres, open end

R901052141

Cable set MAC8/AE/SF/3M

Cable for analogue inputs (X4), 3 metres, open end

R901052069

Cable set MAC8/AEA/SF/3M

Cable for analogue inputs/outputs (X1), 3 metres, open end

R901052150

Cable set MAC8/DEA/SF/3M

Cable for digital inputs/outputs (X5), 3 metres, open end

R901074828

Cable set MAC8/PC/RS232/5M

Cable for PC-MAC8 RS232 interface (X3.4), 5 metres

R901074832

Cable set MAC8/PC/RS422/RS232/ADAPT/5M

Cable for PC-MAC8 RS422 with RS232 adapter (X3.4), 5 m

R901074837

Cable set MAC8/PC/RS422/RS232/ADAPT/30M Cable for PC-MAC8 RS422 with RS232 adapter (X3.4), 30 m

R901074840

Cable set MAC8/PC/RS422/RS232/ADAPT/50M Cable for PC-MAC8 RS422 with RS232 adapter (X3.4), 50 m

R901058546

SYS-MAC8- D/E

Installation CD for MAC8 Tools

366
4/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

RE 30156/04.05

Software engineering
Creation of program with MACpro

Acquisition of measured data

Windows version with integrated editor with


command highlighting

12 recording channels with start and stop trigger

Creation of project groups for the management of individual


programs on the slots, with automatic change-over

Graphic and numeric representation (DBF format) of recorded channels

Global header files for common definitions

Continuous data recording (Trend)

Recording option for all process variables

Programs can be organised in modules (files)


Nesting depth for up to 50 subroutines

Commissioning functions

Change-oriented compiling and transfer to the MAC8

Inputs can be simulated

Reference list of variables and subroutines used

Outputs can be set

Automatic comparison of version PC <-> MAC8

Analogue output variables can be set

Saving of different desktop settings

Inching mode for optimising the controller

Program saved in the flash

Activation / deactivation of individual controller components

Debugging

Project-related administration of:

On-line help for Syntax, Tools and Keys

programs

Tracing of program execution (trace)

configurable programming user interface

Process variable tracing by means of Trend

system parameters

Program view (View) with search functions

measured data

Function level display (call hierarchy)


5 break points are managed

System requirements of MACpro:

Stop / Start / Continue and Single Steps (Single, Step,


Stepover) of individual or all programs

IBM-PC or compatible system

Saving of memory image (program with data)


View of variables
All variable windows can be selected by means of hot keys
or from the menu; flexible window size
Configurable variable window (mix-variables) with hexadecimal, decimal, binary and floating point representation: Simple
inclusion of optional variables from the program view into the
tracing window and structuring by means of comments

Windows NT, Windows 2000, Win XP


Processor 300 MHz or faster
Min. 64 MB RAM (recommended: 128 MB)
Min. 100 MB free hard disk space
The program is installed from a CD
(SYS-MAC-8-D/E, material no. R901058546)

Setup window with all axis-specific process variables


System parameter assistant

Overview of controller functions


Position controller:

Position-dependent braking

Following controller

External controller function via NC program

Alternating control (position / pressure)

Following operation

Force limitation in positive and negative direction

Direction-dependent gain adjustment

Velocity override
Gain can be changed via NC program

Inflected gain characteristic curve

Interpolation of up to 32 axes

Fine positioning

Pre-acceleration

Residual voltage principle

Force / distance; force / time curves

Compensation of zero point offsets

Position/input value curves

State feedback

Transformation of coordinates of spatial axes

Command value feedforward


Control output limitation by means of NC program

367
RE 30156/04.05

Industrial Hydraulics Bosch Rexroth AG

VT-MAC8

5/16

Overview of controller functions (continued)


Status controller:

Synchronisation controller:

Velocity feedback

Synchronisation of optional groups of up to 32 axes that can


be varied during operation

Acceleration feedback

Active synchronism with force limitation or parallel making


way

Pressure feedback
External feedback

Passive synchronism with tilt compensation control, with


definable, average counterforce

Pressure / force controller:

Synchronisation offsets of the axes can be dynamically


changed

PID controllers
I-component can be activated/deactivated via window
Differential pressure evaluation

Axes can be dynamically added to or withdrawn from the


synchronised group (also during operation)

P / Q pilot control

Relative synchronism, also in opposite direction

Various modes for the transition from position to force con-

troller

Monitoring functions:
Dynamic following error monitoring

Velocity controller:

Traversing range limits (electronic limit switches)

PI controllers

Cable break monitoring for incremental and SSI encoders

I-component can be activated/deactivated via window

Cable break monitoring for sensors with 4 to 20 mA output


Valve monitoring
Encoder voltage monitoring

NC interpreter
The NC interpreter organises the execution of the 32 parallel
NC programs. Each program operates sequentially on its own.
The change-over between parallel programs takes place after
a program line was worked off. In the case of commands that
wait for an event (e.g.: WAIT, POS), branching to the next
program takes place immediately after the event query in order
not to hinder the execution of other programs. All system re-

sources are available to all programs (I/O, axes, variables etc.).


Programs can start, stop or delay each other. This concept allows optimum imaging of the sequence structure of the machine in the NC program of the MAC8.

NC interpreter / multiplexer
0

10 11 12

...

...

26 27 28 29 30 31

Start / stop
Process data
acquisition

Main program
Operating
mode management

Manual operation
Automatic operation

Hand
Auto
OFF
Bus protocol
data transfer etc.

Start

02

368
6/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

RE 30156/04.05

Programming language ECL-Win


The data organisation of the MAC8:

Program sequence control:

Numeric variables (integers):

IF ELSE

Instruction

V:

Standard variables

WHILE

Loop

P:

Local variables

{..}

Command block

N:

Process variables

[..]

Bundling of commands

BEGIN END

Program definition

A:

Custom fields

Label

S:

System parameters

JUMP <label> or <soubroutine>

Fields (integers):

Real variables:
R:

START/STOP/BREAK/CONT<program>
Floating point figures

WAIT <time> or <condition>


Data manipulation:

Logic variables:
I:

Inputs

DIM

O:

Outputs

COPY

Field copying function

Process flags

SET

Assign variable

F:
Signs and operators:
<num. sign>

{- | ! | #}

<num. operator>

{* | / | + | - | & |

<num. real operator>

Field declaration

MSET

Preset fields

PSET

Assign local variable

Axis/process funcitons:

| |^ | << | >>}

AXINIT

Initialise axes

{ sin | cos |

AXSET

Take over axis data

tan | asin | acos | atan

STOP

Interrupt axis movement

| sqrt

HALT

Immediate halt of axis movement

<log. operator>

{& | | | ^ }

POS HALT

Immediate halt of axis movement

<num. comp. operator>

{<= | >= | <> |< |>


| = }

BREAK

Interrupt axis movement

CONT

Resume axis movement

Compiler instructions:

EQUIT

Acknowledge axis esrror

<comment>

LOCK

Lock axis control

#include

<file name>

UNLOCK

Unlock control

#modul

<file name>

OVER

Determine axis override

#define

<name> <text>

ACC

Acceleration () of axis

#global

<file name>

VEL

Axis velocity

Acquisition of measured values:

POS

Position axis

TIMER

Timer

SYNCH

Define axes to be synchronised

TRACE

Oscilloscope function

LIN

Linear interpolation

FORCE

Force control

Dialogue commands (hand-held control box or terminal):


DIALOG

Start dialogue

DAC

Voltage output

WINDOW

Define window

FUNC

Axis functions

DISPLAY

Output variable or text

SIMU

Simulation of axis

INPUT

Input definition

HOME

Referencing

LEVEL

User level

TABLE

Create process curve

READ_KEY

Softkey query

VIRTUAL

Define virtual axes

SSET

String assignment

REAL

Inverse calculation formula to


VIRTUAL

FREEZE

Freeze axis velocity

Special commands:
CALL <address>
START/STOP TASK

Call C-function
Start C-task

For operating parameters that are not listed here, it is usually


possible to enter a constant, a variable or a term!

369
RE 30156/04.05

Industrial Hydraulics Bosch Rexroth AG

VT-MAC8

7/16

Technical data
Operating voltage
Current consumption

UO 18 to 36 VDC / max 3.6 A


Master without axis 500 mA
Master with axis 800 mA
Slave 400 mA

Processor

MPC860 and MPC555

Memory

16 MB SDRAM, 16 MB flash, 8 KBytes DPR


4 MB Flash (MPC555)
2 MB SRAM (MPC555)

Analogue inputs:
Voltage inputs (differential inputs)

10 V 12 bits with 4-fold oversampling

Input voltage

UI max. +10 V to 10 V

Input resistance

RI 160 k

Resolution

5 mV

Current inputs
Input current

II 4 20 mA, 20 mA

Input resistance

R 100

Power loss

IL 12 A

Resolution

4 A

Analogue outputs:
Voltage outputs
Output voltage

Unom 10 V PWM (pulse-width modulation)

Output current

Imax 10 mA

Load

Rmin 2 k

Current outputs
Output current, normalised

Inom 20 mA

Load

Rmax 500

Resolution
Serial interfaces

1 mV
Standard RS232 (19.2 KBaud)
RS485 (115 KBaud)
Optional Profibus DP (max. 12 MBaud)
CAN open (max. 1 MBaud)

Switching inputs

Number 32
Logic level log 0 (low) 0 V to +5 V
log 1 (high) +10 V to 36 V
RI 3 k 10 %

Switching outputs

Number 24
Logic level log 0 (low) 0 V to +5 V;
log 1 (high) +10 V to 36 V;
Current carrying capacity up to 50 mA

02

370
8/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

Technical data (continued)


Digital position transducers
Incremental transducer
Transducer with TTL output
Input voltage

log 0 0 to 1 V
log 1 2.8 to 5.5 V

Input current

log 0 0.8 mA (at 0 V)


log 1 0.8 mA (at 5 V)

Max. frequency referred to Ua 1

fmax 250 kHz, 24 bits

SSI position transducer


Coding

Gray code

Data width

Adjustable up to max. 28 bits

Line receiver (TTL)


Input voltage

fmax 250 kHz


log 0 0 to 1 V
log 1 2.5 to 5.5 V

Input current

log 0 0.5 mA (at 0 V)


log 1 0.5 mA (at 5 V)

Line driver
Output voltage

log 0 0 to 0.5 V
log 1 2.5 to 5.5 V

Permissible operating temperature range

0 to 50 C

Storage temperature range

20 to 70 C

Weight:
Rack 1

m 1000 g

Rack 5

m 1800 g

Rack 8

m 2500 g

Master card

m 400 g

Slave card

m 350 g

Blank cover

m 100 g

RE 30156/04.05

371
RE 30156/04.05

Industrial Hydraulics Bosch Rexroth AG

VT-MAC8

9/16

Pin assignment of master card VT-MAC8


Front panel shows: VT-MAC8-1X/K-PM1

X1a RJ-45; 100BaseT Ethernet


2

TPO

TPI+

75K-GND

75K-GND

TPI

75K-GND

75K-GND

X3.1

X1a

CAN open

n.c.

CAN_Lx

n.c.

100BaseT

TPO+

CAN_Hx

10BaseT

Rexroth

GNDCANx

n.c.

n.c.

n.c.
X1b

n.c.

6
7
8
9

TPO+

TPO

TPI+

n.c.

n.c.

TPI

n.c.

n.c.

digital I/O

X1b RJ-45; 10BaseT Ethernet


X3.3

Profibus DP

n.c.

n.c.

VP
n.c.
3
4

1
2

8
X3.1
3

Voltage supply
Shield

GND

+24 V

GND
6

TxD
GND

Uin4D

V 24

RS485

fieldbus

X6

DGND

RxD

Uin2D
Uin3D

X3.4

AGND
Uin1D

X4

Uin3C
Uin4C

X3.3

X3.4

24V OK RUN BUS

24V

X6

MAC-8

RxD
TxD+

5V
RxD+

RS485 / V24

analog in

Uin1C
Uin2C

CAN

Analogue in

CNTR -P
n.c.

X4

RxD/TxD -P
RxD/TxD -N

X5

TxD

02

372
10/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

Pin assignment of master card VT-MAC8


Front panel shows: VT-MAC8-1X/K-PM2

X5
Pin

Rexroth
X1a
100BaseT

43

10BaseT

44
45
46
analog I/O

X1b

47

digital I/O

48

encoder 1

X1

X5

49

Digital I/O
Description

Pin

Description

22

Reserved

23

In0

24

In3

25

In6

26

In9

27

In12

28

In15

29

In18

Reserved
In2
In5
In8
In11
In14
In17

50

In20

51

In23

52

In26

53

In29

54

Out0

55

Out3

56

Out6

30
31

X2.1

analog in

encoder 2

32

X4

33

CAN

X2.2

57

X3.1

58

RS485 / V24

fieldbus

X3.3

34

59
X3.4

60

24V

61

X6

62
MAC-8

Description

Reserved

In1

In4

In7

In10

In13

In16

In19

In22

10

In25

11

In28

12

In31

13

Out2

14

Out5

15

Out8

16

Out11

17

Out14

18

Out17

19

Out20

20

Out23

21

0V

In21
In24
In27
In30
Out1

35

Out4

36

Out7

37

Out10

38

Out13

39

Out16

40

Out19

41

Out22

42

0V

Out9
Out12
Out15
Out18

24V OK RUN BUS

Pin

Out21
0V

RE 30156/04.05

373
RE 30156/04.05

Industrial Hydraulics Bosch Rexroth AG

VT-MAC8

11/16

Pin assignment of master card VT-MAC8


Front panel shows: VT-MAC8-1X/K-PM4

X1 Analogue I/O on master card


Pin

Rexroth

1
X1a

Pin Description
n.c.

100BaseT

n.c.
2

n.c.

10BaseT

3
4
analog I/O

5
6

digital I/O

encoder 1

IUin1A

Current / voltage input 0.. 20 mA / 10 V


17 Current / voltage input 0.. 20 mA / 10 V

IUin2A

Current / voltage input 0.. 20 mA / 10 V

IUin2B

18 Current / voltage input 0.. 20 mA / 10 V

AGND

X5

X2.1

Analogue ground
19 Current / voltage input 0.. 20 mA / 10 V

IUin3B

Current / voltage input 0.. 20 mA / 10 V

IUin4A

20 Current / voltage input 0.. 20 mA / 10 V

IUin4B
AGND

16 Analogue ground

IUin1B

IUin3A
X1

Analogue ground
15

n.c.
AGND

X1b

14

AGND

Current / voltage input 0.. 20 mA / 10 V


21 Analogue ground

Uout1

10 V

Uout2

22 10 V

10 Uout3

10 V

Uout4

23 10 V

analog in

encoder 2

11 AGND

X4

X2.2

Iout1

24 20 mA

12 Iout2

20 mA

Iout3

25 20 mA

13 Iout4

20 mA

CAN

encoder 3

X2.x

X3.1

Pin
1

fieldbus

encoder 4

X2.3

X3.3

X2.4

Analogue ground

Encoder plug
INC
/Ua 2

+Clk

Ua 0

/ Ua 0

Ua 1

/ Ua 1

7
8

SSI

Clk
Ua 2

24V OK RUN BUS

9
24V

X6

10

Data
0V

11
MAC-8

0V
+Data

12

5 V TTL

13

n. c.

n. c.

14

Reserved

Reserved

15

n. c.

n. c.

02

374
12/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

Pin assignment of slave card VT-MAC8-1X/K-AX4


X1
Rexroth

1
address

2
S1

Analogue I/O

Pin
Iin1C

Current input 20 mA

Iin2C

14 Current input 20 mA

AGND
Iin3C

analog I/O

5
6

X1

encoder 1

Current input 20 mA
16 Analogue ground

IUin1A

Current / voltage input 0.. 20 mA / 10 V

IUin1B

17 Current / voltage input 0.. 20 mA / 10 V

IUin2A

Current / voltage input 0.. 20 mA / 10 V

IUin2B

18 Current / voltage input 0.. 20 mA / 10 V

AGND

Analogue ground

IUin3A

19 Current / voltage input 0.. 20 mA / 10 V

IUin3B

Current / voltage input 0.. 20 mA / 10 V

IUin4A

20 Current / voltage input 0.. 20 mA / 10 V

IUin4B

Current / voltage input 0.. 20 mA / 10 V

Uout1

10 V

Uout2

22 10 V

10 Uout3

10 V

AGND

Uout4
X2.1

Analogue ground
15 Current input 20 mA

Iin4C
AGND

21 Analogue ground

23

11 AGND
Iout1
Iout3

10 V
Analogue ground

24

12 Iout2

encoder 2

on slave card

Pin Description

20 mA
20 mA

25

13 Iout4

20 mA
20 mA

X2.2
X2.x
encoder 3

Pin
1

Encoder plug
INC
/Ua 2

encoder 4

X2.3

+Clk

AX-4

Slot
2

Slot 2

Slot 3

Ua 0

Slot 4

/ Ua 0

Slot 5

Ua 1

Slot 6

/ Ua 1

Slot 7

Slot 8

24V OK RUN BUS

Address

X2.4

S1

SSI

Clk
Ua 2

9
10

Data
0V

11

0-1

Not permitted

9-F

Not permitted

0V
+Data

12

5 V TTL

13

n. c.

n. c.

14

Reserved

Reserved

15

n. c.

n. c.

Caution!
Address the card according to the slot!

RE 30156/04.05

375
RE 30156/04.05

Industrial Hydraulics Bosch Rexroth AG

VT-MAC8

13/16

Unit dimensions (nominal dimensions in mm)


VT-MAC8-1X/K-RACK5

VT-MAC8-1X/K-RACK1

System with 5 slots

System with 1 slot

175,4

Rexroth

X1a

Rexroth

Rexroth

Rexroth

Rexroth

address

address

address

address

S1

S1

S1

(37,7)

(37,7)

134,6

Rexroth

X1a

S1

X1b

X1

X1

X1

X1

X5

X2.1

X2.1

X2.1

X2.1

X4

X2.2

X2.2

X2.2

X2.2

X3.1

X2.3

X2.3

X2.3

X2.3

X1

190,5

190,5

X1b

X5

X2.1

X4

X2.2

X3.1

X2.3

02

X2.4

X2.4

X2.4

X3.3

X2.4

X2.4

X3.4

X3.3

24V OK RUN BUS

24V

24V OK RUN BUS

24V OK RUN BUS

24V OK RUN BUS

X6

24V OK RUN BUS

37,7

37,7

24V OK RUN BUS

MAC-8

AX-4

160

AX-4

AX-4

24V

X6

AX-4

MAC-8

79

376
14/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

Unit dimensions (nominal dimensions in mm)


VT-MAC8-1X/K-RACK8
System with 8 slots

238,8

(37,7)

198

Rexroth

X1a

Rexroth

Rexroth

Rexroth

Rexroth

Rexroth

Rexroth

Rexroth

address

address

address

address

address

address

address

S1

S1

S1

S1

S1

S1

S1

190,5

X1b

X1

X1

X1

X1

X1

X1

X1

X1

X5

X2.1

X2.1

X2.1

X2.1

X2.1

X2.1

X2.1

X2.1

X4

X2.2

X2.2

X2.2

X2.2

X2.2

X2.2

X2.2

X2.2

X3.1

X2.3

X2.3

X2.3

X2.3

X2.3

X2.3

X2.3

X2.3

X2.4

X2.4

X2.4

X2.4

X2.4

X2.4

X2.4

X2.4

X3.3

24V OK RUN BUS

37,7

24V OK RUN BUS

24V

24V OK RUN BUS

24V OK RUN BUS

24V OK RUN BUS

24V OK RUN BUS

24V OK RUN BUS

24V OK RUN BUS

X6

MAC-8

AX-4

AX-4

AX-4

221,3

AX-4

AX-4

AX-4

AX-4

RE 30156/04.05

377
RE 30156/04.05

Industrial Hydraulics Bosch Rexroth AG

VT-MAC8

15/16

Unit dimensions (nominal dimensions in mm)


VT-MAC8-1X/K-RACK1/5/8
219,5

265,9

91

02

(min. 310,5)

378
16/16

Bosch Rexroth AG

Industrial Hydraulics

VT-MAC8

RE 30156/04.05

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

379

Digital axis control HNC100

RE 30131/07.05
Replaces: 03.05

Types VT-HNC100-1 and VT-HNC100-2

Component series 2X

H/D 20451

Table of contents
Contents

Page

Features

Ordering code

Software configuration

Overview of controller functions

System overview

Overview of NC commands for the sequence control


Technical data
Pin assignment

5
6 and 7

VT-HNC100-1-2X/.-08

VT-HNC100-2-2X/.-16

VT-HNC100-1-2X/.-24

10

Unit dimensions

11

Preferred types

11

1/12

380
2/12

Bosch Rexroth AG

Hydraulics

VT-HNC100

RE 30131/07.05

Features
The digital axis control HNC100 is a programmable NC control
for a closed-loop controlled axis. It meets the specific requirements of closed-loop controlling of hydraulic drives and also offers the possibility of controlling electrical drives.
With regard to immunity to interference, mechanical resistance
to vibration and shock, and climate-proofness, the HNC100 is
designed for use in harsh industrial environments. It conforms
with EC Directives (CE mark).

Operation:
Comfortable administration of data on the PC
Swift changing of data by means of hand-held control box
BB-3 (see RE 29798) or control panel BF-1 (see RE 29794)
Process interfacing:
8, 16 or 24 digital inputs and outputs each, Profibus DP,
CANopen or INTERBUS-S for communication with a PLC

Fields of application:

Hydraulic axes:

Machine tools, plastics processing machines, special machines

Measuring system:
Incremental or absolute (SSI)
Analogue 0 to 10 V and 4 to 20 mA
Reference voltage 10 V

Presses
Transfer lines

Voltage or current control variable output

Rail-bound vehicles

NC language with subprogram technique and conditional


jumps

Freely configurable controller variants


Position controller, pressure/force controller
Position-dependent braking
Alternating closed-loop control (position/pressure)
Synchronisation control for 2 axes

Own NC program for function sequences

Further information:

Local CAN bus for parameterising several HNC100

Installation instructions and interconnection diagrams


VT-HNC100-.-2X, see RE 30131-Z

Programming:
User programming with a PC

Ordering code
VT-HNC100

2X

Digital NC control HNC100


Version for 1 hydraulic axis
Version for 2 hydraulic axes

Further details in clear text


=1
=2

0=
Without evaluation electronics
A=
On enquiry only:
Evaluation electronics for 2 inductive position transducers (not possible in conjunction with INTERBUS-S or CANopen)

Component series 20 to 29
= 2X
(20 to 29: unchanged installation and connection dimensions)
Type of installation:
Housing for wall-mounting
Housing for rack installation
For single-axis version:
8 digital inputs/outputs
24 digital inputs/outputs
For 2-axis version:
16 digital inputs/outputs

=W
=M
= 08
= 24

0=
P=
C=
I=
S=

= 16

An interface cable is not included in the scope of supply, but can be ordered separately (3 m long;
other lengths on enquiry). Material no.: R900842349
1)

Additional plug type 6ES7972-0BA20-0XA0 for Profibus DP is not included in the scope of supply, but must be ordered separately! Material no: R900050152

Without bus interfacing


Profibus DP 1)
CANopen
INTERBUS-S
SERCOS

381
RE 30131/07.05

Hydraulics Bosch Rexroth AG

VT-HNC100

3/12

Software configuration
Configuration
The operation of the HNC100 is based on the creation of
application-specic data sets. These data sets are generated on a PC and sent to the HNC100 via the serial interface.
The combination of the user program and data sets is called
project. This software conguration is carried out according
to the following steps:
1. The tasks to be performed by the HNC100 are to be defined
and stored in a sequence chart. The definition also refers to
the meaning of inputs and outputs and the parameters used.

Support for the definition of parameters used in the NC


program
Dialogue window for on-line setting of parameter values
Comprehensive options for displaying process data, digital
inputs, outputs and flags
Recording and graphical representation of up to four process variables via selection of trigger options
Dialogue for the graphical definition of special functions
(determination of function via polygon)

2. The functions of the sequence charts have to be implemented in the form of a sequence of NC commands.

System requirements:

3. The machine data (selection of encoders and controllers)


and the parameters of the NC program have to be defined.

Windows 9x or Windows NT

4. The data are sent to the HNC100.

IBM PC or compatible system


Processor: Intel 80286 or higher (recommendation: 80486
or better)

5. Settings and program sequences are optimised on the machine.

Min. 8 MB RAM (recommendation: 16 MB)

PC program WIN-PED

Note:

The PC program WIN-PED helps the user perform conguration tasks. It is used for programming, setting and diagnostics
with regard to the HNC100.

The PC program WIN-PED (SYS-HNC-WINPED5-C01) is


not included in the scope of supply. It can be ordered separately or downloaded free of charge on the Internet!

Scope of functions:

Order for CD-ROM: Material no. R900725471

Comfortable dialogue functions for on-line or


off-line setting of machine data

Download on the Internet: www.boschrexroth.de/hnc100

10 MB free hard disk space

Enquiries: support.nc-systems@boschrexroth.de

NC editor with integral syntax check and program compiler

Overview of controller functions


Position controller:

Pressure/force controller:

PDT1-controller

PIDT1-controller

Linear gain characteristic curve

I-component can be cut in and out via window

Direction-dependent gain adjustment

Differential pressure evaluation

"Inflected" gain characteristic curve

Own scanning rate

Gain alteration possible via the NC program

Velocity controller:

Fine positioning

PI-controller

Residual voltage principle

I-component can be cut in and out via window

Zero point error compensation

Monitoring functions:

State feedback

Dynamic following error monitoring

Command value feedforward

Traversing range limits (electronic limit switches)

Limitation of control output via the NC program

Cable break monitoring for incremental and SSI encoder

"Position-dependent braking"

Cable break monitoring for sensors with 4 to 20 mA output

Intermediate electronics for use with commercial NC controls


Synchronisation control

In the event of a fault, the output "no error" is reset and


the controller deactivated !

02

382
4/12

Bosch Rexroth AG

Hydraulics

VT-HNC100

RE 30131/07.05

System overview
Higher-level control
Possible interfaces to the HNC100:
Analogue signals
Digital inputs/outputs
Serial interface
Field bus systems
(Profibus DP, CANopen, INTERBUS-S, SERCOS)

4
8

reset

X7
9
78 A

3456

OUT 1-8

analog IN/OUT

3456

S2

BCD

BCD

9
78 A

1
EF 2

S1

1
EF 2

shield
GND
18-36V

X5

X4
X8
local CAN

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

IN 1-8

encoder

COM / local CAN

local CAN

X8

X3
COM / local CAN

X4

PIN4=24VDC
RUN
5V CPU

Further
HNC100

X1

X6
X2

HNC100

HNC100

3
7

6
2
1
1 Single-rod cylinder
2 Integrated position measuring system
3 Servo, proportional or high-response valve
with integral control electronics
4 HNC100

5
6
7
8

Connecting cable
Pressure transducer
Sandwich plate shut-off valve (with plug-in switching amplifier)
Local CAN bus

383
RE 30131/07.05

Hydraulics Bosch Rexroth AG

VT-HNC100

5/12

Overview of NC commands for the sequence control


At the time of publishing this data sheet, the following NC
commands are available for programming of sequences 1):
Definition part:

Sequence control:

/TRIG

Definition of a switching point

G01

Point-to-point travel

/E

Suppression of limit switches

G30

Point-to-point travel for oscillating movements

/OVER

Override of velocity

BREAK

Interruption of G01 or G30

/KD

Definition of a curve

STOP

Deceleration and termination of G01, G30

/KT

Scanning time of a curve

G53/G54 Zero point compensation "OFF/ON"

/DFN

Normalisation factor for curve polygon

G70

Activation of closed-loop velocity control

/SE

Definition of system inputs

G55

/SA

Definition of system outputs

Setting/reading of values of zero point compensation

G63

Transition from closed-loop pressure/velocity


control to closed-loop position control

NC interpreter:
KURVE

Start and stop of the curve function

Output of a voltage

KP

Alteration of controller gain

CLR

Resetting of output or flag

SET

Setting of output or flag

IF

Conditional branching

G27, G28 Activation of pressure controller in dependence


upon a position

JMP

Jump to a flag (L000 to L1999)

G60

Activation of pressure controller

JSR

Subroutine call

G61

Activation of pressure limitation

M17

End of subroutine

G62

Deactivation of pressure limitation

M02

End of main program

M22

Variable for global variables

Setting the actual and command value for the


position controller

Variable for local variables

G04

Waiting time

Lxxx

Jump flag

M00

Waiting for input or flag

Value assignment for an R parameter

M90

Setting output or flag

G64

Limitation of control variable

M91

Resetting output or flag

BINE

Reading of binary-coded inputs

BINA

Output to binary-coded outputs

M22I

Setting of command value for position controller

G65/G66 Position monitoring in closed-loop pressure control ON/OFF

M33/M34 Activation/deactivation of position controller


M35/M36 Activation/deactivation of synchronism
G26

Traversing to limit stop, closed-loop controlled

G25

Traversing to limit stop, open-loop controlled

1)

This scope of functions is valid for the current software version. The efficiency of the system is continuously extended
within the framework of software development.

02

384
6/12

Bosch Rexroth AG

Hydraulics

VT-HNC100

RE 30131/07.05

Technical data (for applications outside these parameters, please consult us!)
Operating voltage
Power consumption
Processor
Memory
Analogue inputs 1):
Voltage inputs (differential inputs)
Number of channels
Input voltage
Input resistance
Resolution
Non-linearity
Calibration tolerance 2)
Current inputs
Number of channels
Input current
Input resistance
Resistance between Pin Iin 1 and analog_GND
Power loss
Resolution
Impedance inputs 3)
Number of channels
Input voltage
Input resistance
Resolution
Non-linearity
Calibration tolerance 2)
Analogue outputs:
Voltage outputs 4)
Number of channels
Output voltage
Output current
Load
Current outputs 4)
Number of channels
Output current
normalised
not normalised
Load
Residual ripple content
Resolution
Non-linearity
within the range of 9.5 V to +9.5 V
within the range of 10 V to 9.5 V and +9.5 V to +10 V

UO 18 to 36 VDC
8 W (plus power for connected sensors/actuators)
16/32-bit MC68376
Flash EPROM 1 MB; EEPROM 8 KB; RAM 256 KB (main
memory)

Pint

4
UI +10 V to 10 V measurable (max. +15 V to 15 V)
RI 200 k 2 %
5 mV
< 10 mV
max. 40 mV (with factory setting)

II
RI
R
IL

4
4 mA to 20 mA
100 0.2 %
0 to 500
0.1 to 0.4 % (at 500 between pin Iin 1 and analog_GND)
5 A

4
Uimp 10 V to +10 V
Rimp > 10 M
5 mV
< 10 mV
max. 40 mV (with factory setting)

4
Unom 10 V to +10 V (max. 10.7 V to +10.7 V)
Imax 10 mA
Rmin 1 k

Inom
Imax
Rmax

2
4 mA to 20 mA
23 mA
500
60 mV (without noise)
1.25 mV
15 mV
35 mV

1)

Not all of the channels can be used simultaneously. The voltage inputs and the current inputs are provided with a common pin so that either the voltage input or the current input
can be used at a time. The current can be looped through
several current measuring devices. Otherwise, a jumper must
be provided from pin Iin to pin analog_GND.

3)

Due to the characteristics of these high-resistance inputs,


no internal protective circuits with diodes or capacitors
may be used. For this reason, when connecting analogue
signals to inputs Uimp1 to Uimp4 , connect all the required
protective features such as shield, EMC protection and
signal lter externally in the incoming circuit.

2)

If the factory settings are not sufcient, the measuring equipment


can be calibrated on site according to the system requirements.

4)

Outputs Uout 1 and Iout 1 as well as Uout 2 and Iout 2


are electrically coupled. Normalisation can be set to voltage
or current by means of the software.

385
RE 30131/07.05

Hydraulics Bosch Rexroth AG

VT-HNC100

7/12

Technical data (continued)


Serial interfaces

Switching inputs

Switching outputs

Standard RS232 (9.6 KBaud)


Optional Profibus DP (max. 12 MBaud)
CANopen, INTERBUS-S
Number 8, 16 or 24
Logic level log 0 (low) 5 V; log 1 (high) 10 V to UO; Ri = 3 k 10 %
Connection Flexible conductor up to 1.5 mm2
Number 8, 16 or 24
Logic level log 0 (low) 2 V; log 1 (high) UO; Imax = 50 mA
Connection Flexible conductor up to 1.5 mm2

Digital position transducers:


Incremental transducer (transducer with TTL output)
Input voltage
Input current
Max. frequency referred to Ua 1
SSI transducer
Coding
Data width
Line receiver (TTL)
Input voltage
Input current
Line driver
Output voltage
- EnDat transducer
Voltge supply to position transducer by the
HNC100
Max. voltage for all input signals
Inductive position transducers:
Number
Voltage supply

Reference voltage
Dimensions (W x H x D):
VT-HNC100-1-2X/.-08-.-.
VT-HNC100-2-2X/.-16-.-. and VT-HNC100-1-2X/.-24-.-.
Permissible operating temperature range
Storage temperature range
Weight:
VT-HNC100-1-2X/.-08-.-.
VT-HNC100-2-2X/.-16-.-. and VT-HNC100-1-2X/.-24-.-.
Further technical details on enquiry.

log 0
log 1
log 0
log 1
fmax

0 to 1 V
2.8 to 5.5 V
0.8 mA (at 0 V)
0.8 mA (at 5 V)
250 kHz
Gray code
Adjustable up to max. 28 bits

log 0
log 1
log 0
log 1

0 to 1 V
2.8 to 5.5 V
0.8 mA (at 0 V)
0.8 mA (at 5 V)

02
log 0 0 to 0.5 V (at 120 )
log 1 2.5 to 5.5 V (at 120 )
Interface in preparation
U UO or +5 VDC 5 %; max. 200 mA
Umax UO 1 V (the signals are not opto-decoupled)
2
Ueff 2 V (Imax = 30 mA / channel)
balanced to ground, short-circuit-proof, can be synchronised
between 4.8 and 5.2 kHz, optional compensation capacitor
of 220 nF; amplitude stability 0.2 % /10 K; carrier frequency
5 kHz 2 %; inductive transducers in half and full bridge circuit
and 3- and 4-conductor circuit; linearity error < 0.1 %
Uref +10 V 25 mV and 10 V 25 mV (20 mA each)
71 x 155 x 204 mm
106.5 x 155 x 204 mm
0 to 50 C
20 to +70 C
m 1.0 kg
m 1.2 kg

Note!
For details regarding environment simulation testing in the fields
of EMC (electromagnetic compatibility), climate and mechanical
stress, see RE 30131-U (declaration on environmental compatibility).

386
8/12

Bosch Rexroth AG

Hydraulics

VT-HNC100

RE 30131/07.05

Pin assignment VT-HNC100-1-2X/.-08 (single-axis version)

reset

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

IN 1-8

local CAN

X8

X3

encoder

COM / local CAN

RUN
5V CPU

X7

Note!
The pins identied with res are
reserved and must not be connected.

OUT 1-8

analog IN/OUT

3456

9
78 A

BCD

9
78 A

S2
3456

S1

BCD

S1, S2:
Address,
baud rate
CAN

X4
PIN4=24VDC

1
EF 2

X4: COM / local CAN


Pin 1 CAN_GND
2 TxD
3 CTS
4 24 VN
5 0 VN
6 RxD
7 RTS
8 CAN_H
9 CAN_L

1
EF 2

X8: local CAN


Pin 1 CAN_GND
2 res
3 res
4 res
5 res
6 res
7 res
8 CAN_H
9 CAN_L

shield
GND
18-36V

X5

X3: encoder
Pin incremental SSI
/Ua 2
1
Clock
2
Ua 0
3
/Ua 0
4
Ua 1
Data
5
/Ua 1
/Data
6
/Clock
7
Ua 2
8
res
9
10 0 VN
11 res
12 5 VTTL (max. 150 mA)
13 res
14 24 VN (max. 200 mA)
15 res

X1

X6
X2

HNC100

via optical fibre adapter

X5: communication with higher-level control


Pin
Profibus
INTERBUS-S
SERCOS
DP
(OUT)
n.c.
DO 2
1
n.c.
DI 2
2
RxD/TxD-P
GND 2
3
CNTR-P
n.c.
4
DGND
Udd
5
VP
/DO 2
6
n.c.
/DI 2
7
RxD/TxD-N
n.c.
8
n.c.
BCI
9

X7: communication with higher-level control


Pin CANopen
inductive
INTERBUS-S
(IN)
n.c.
Supply 1 +
DO1
1
CAN_L
Supply 1
DI1
2
Signal 1 +
GND1
3 CAN_GND
n.c.
Signal 1
n.c.
4
n.c.
Supply 2 +
n.c.
5
n.c.
Supply 2
/DO1
6
CAN_H
Signal 2 +
/DI1
7
n.c.
Signal 2
n.c.
8
n.c.
Sync IN/OUT
n.c.
9

X6:
Pin

voltage supply
1 Shield
2 GND
3 18 - 36 VDC

X2: analog IN / OUT


Iin 1
Uin 1 +
Pin 1
Uin 1
2
Uin 2 +
Iin 2
3
Uin 2
4
Uin 3 +
Iin 3
5
Uin 3
6
Uin 4 +
Iin 4
7
Uin 4
8
Iout 2
9
10 Uout 2
11 analog_GND
12 Uref = + 10 V
13 Uref = 10 V
14 Iout 1
15 Uout 1
16 Uout 3
17 Uout 4
Iin 1 +
18
Iin 2 +
19
Iin 3 +
20
Iin 4 +
21
22 Uimp 1
23 Uimp 2
24 Uimp 3
25 Uimp 4

X1: digital I/O


Pin 1 IN1
2 IN2
3 IN3
4 IN4
5 IN5
6 IN6
7 IN7
8 IN8
9 OUT1
10 OUT2
11 OUT3
12 OUT4
13 OUT5
14 OUT6
15 OUT7
16 OUT8
17 /error
18 res

387
Hydraulics Bosch Rexroth AG

VT-HNC100

RE 30131/07.05

9/12

Pin assignment VT-HNC100-2-2X/.-16 (2-axis version)


X8: local CAN
Pin 1 CAN_GND
2 res
3 res
4 res
5 res
6 res
7 res
8 CAN_H
9 CAN_L
X4
PIN4=24VDC
COM / local CAN

RUN
5V CPU

X7
X2.1

S2

9
78 A

3456

analog IN/OUT 1

3456

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

BCD

9
78 A

IN 1-8

1
EF 2

S1

BCD

1
EF 2

S1, S2:
Address,
baud rate
CAN

X3.2

reset

encoder 1

local CAN

X8

X3.1

shield
GND
18-36V

IN 1-8
encoder 2

The pins identied with res


are reserved and
must not be connected.

X4: COM / local CAN


Pin 1 CAN_GND
2 TxD
3 CTS
4 24 VN
5 0 VN
6 RxD
7 RTS
8 CAN_H
9 CAN_L

17
18
19
20
21
22
23
24
17
18
19
20
21
22
23
24
res
res

X2.2
analog IN/OUT 2

Note!

X5
X6

OUT 1-8

X1.1

X1.1 and X1.2: digital


IN/OUT
X1.2
Pin X1.1
IN1
IN9
1
IN2
IN10
2
IN3
IN11
3
IN4
IN12
4
IN5
IN13
5
IN6
IN14
6
IN7
IN15
7
IN8
IN16
8
OUT1 OUT9
9
10 OUT2 OUT10
11 OUT3 OUT11
12 OUT4 OUT12
13 OUT5 OUT13
14 OUT6 OUT14
15 OUT7 OUT15
16 OUT8 OUT16
17 /error res
res
18 res
X6:
Pin

voltage supply
1 Shield
2 GND
3 18 - 36 VDC

OUT 1-8

X3.1: encoder 1
Pin incremental SSI
/Ua 2
1
Clock
2
Ua 0
3
/Ua 0
4
Ua 1
Data
5
/Ua 1
/Data
6
/Clock
7
Ua 2
8
res
9
10 0 VN
11 res
12 5 VTTL (max. 150 mA)
13 res
14 24 VN (max. 200 mA)
15 res
X3.2: encoder 2
Pin incremental SSI
/Ub 2
1
Clock
2
Ub 0
3
/Ub 0
4
Ub 1
Data
5
/Ub 1
/Data
6
/Clock
7
Ub 2
8
res
9
10 0 VN
11 res
12 5 VTTL (max. 150 mA)
13 res
14 24 VN (max. 200 mA)
15 res

X1.2

HNC100

via optical fibre adapter

X5: communication with higher-level control


Pin Profibus
INTERBUS-S
SERCOS
DP
(OUT)
n.c.
DO 2
1
n.c.
DI 2
2
GND 2
3 RxD/TxD-P
CNTR-P
n.c.
4
DGND
Udd
5
VP
/DO 2
6
n.c.
/DI 2
7
n.c.
8 RxD/TxD-N
n.c.
BCI
9
X7: communication with higher-level control
Pin CANopen
inductive
INTERBUS-S
(IN)
n.c.
Supply 1 +
DO1
1
CAN_L
Supply 1
DI1
2
Signal 1 +
GND1
3 CAN_GND
n.c.
Signal 1
n.c.
4
n.c.
Supply 2 +
n.c.
5
n.c.
Supply 2
/DO1
6
CAN_H
Signal 2 +
/DI1
7
n.c.
Signal 2
n.c.
8
n.c.
Sync IN/OUT
n.c.
9

X2.1: analog IN / OUT1


Uin 1 + Iin 1
Pin 1
Uin 1
2
Uin 2 + Iin 2
3
Uin 2
4
res
5
res
6
res
7
res
8
res
9
10 res
11 analog_GND
12 Uref = + 10 V
13 Uref = 10 V
14 Iout 1
15 Uout 1
16 Uout 3
17 res
Iin 1 +
18
Iin 2 +
19
20 res
21 res
22 Uimp 1
23 Uimp 2
24 res
25 res

X2.2: analog IN / OUT2


Iin 3
Uin 3 +
Pin 1
Uin 3
2
Iin 4
Uin 4 +
3
Uin 4
4
res
5
res
6
res
7
res
8
res
9
10 res
11 analog_GND
12 Uref = + 10 V
13 Uref = 10 V
14 Iout 2
15 Uout 2
16 Uout 4
17 res
Iin 3 +
18
Iin 4 +
19
20 res
21 res
22 Uimp 3
23 Uimp 4
24 res
25 res

02

388
10/12

Bosch Rexroth AG

Hydraulics

VT-HNC100

RE 30131/07.05

Pin assignment VT-HNC100-1-2X/.-24 (single-axis version)

X4
PIN4=24VDC
RUN
5V CPU

S2
3456

1
EF 2

3456

9
78 A

BCD

9
78 A

1
EF 2

Note!

X2: analog IN / OUT


Iin 1
Uin 1 +
Pin 1
Uin 1
2
Uin 2 +
Iin 2
3
Uin 2
4
Uin 3 +
Iin 3
5
Uin 3
6
Uin 4 +
Iin 4
7
Uin 4
8
Iout 2
9
10 Uout 2
11 analog_GND
12 Uref = + 10 V
13 Uref = 10 V
14 Iout 1
15 Uout 1
16 Uout 3
17 Uout 4
Iin 1 +
18
Iin 2 +
19
Iin 3 +
20
Iin 4 +
21
22 Uimp 1
23 Uimp 2
24 Uimp 3
25 Uimp 4

shield
GND
18-36V

IN 9-16

IN 17-24

9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
res
res

17
18
19
20
21
22
23
24
17
18
19
20
21
22
23
24
res
res

X5
OUT 1-8

X6
X2

X1.1

OUT 9-16

X1.2

OUT 17-24

X1.3

HNC100

X5: communication with higher-level control


Pin
Profibus
INTERBUS-S
Sercos
DP
(OUT)
n.c.
DO 2
1
n.c.
DI 2
2
RxD/TxD-P
GND 2
3
CNTR-P
n.c.
4
DGND
Udd
5
VP
/DO 2
6
n.c.
/DI 2
7
n.c.
8 RxD/TxD-N
n.c.
BCI
9
via optical fibre dapter

The pins identied with res


are reserved and
must not be connected.

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

X7
S1

BCD

S1, S2:
Address,
baud rate
CAN

reset
IN 1-8

encoder

local CAN

X8

X3

analog IN/OUT

voltage supply
1 Shield
2 GND
3 18 - 36 VDC

COM / local CAN

X6:
Pin

X7:
Pin
1
2
3
4
5
6
7
8
9

communication with higher-level control


CANopen
inductive
INTERBUS-S
(IN)
n.c.
Supply 1 +
DO1
CAN_L
Supply 1
DI1
CAN_GND
Signal 1 +
GND1
n.c.
Signal 1
n.c.
n.c.
Supply 2 +
n.c.
n.c.
Supply 2
/DO1
CAN_H
Signal 2 +
/DI1
n.c.
Signal 2
n.c.
n.c.
Sync IN/OUT
n.c.

X3: encoder
Pin incremental SSI
/Ua 2
1
Clock
2
Ua 0
3
/Ua 0
4
Ua 1
Data
5
/Ua 1
/Data
6
/Clock
7
Ua 2
8
res
9
10 0 VN
11 res
12 5 VTTL (max. 150 mA)
13 res
14 24 VN (max. 200 mA)
15 res
X1.1 to X1.3: digital IN/OUT
X1.2
X1.3
Pin X1.1
IN1
IN9
IN17
1
IN2
IN10
IN18
2
IN3
IN11
IN19
3
IN4
IN12
IN20
4
IN5
IN13
IN21
5
IN6
IN14
IN22
6
IN7
IN15
IN23
7
IN8
IN16
IN24
8
OUT1 OUT9 OUT17
9
10 OUT2 OUT10 OUT18
11 OUT3 OUT11 OUT19
12 OUT4 OUT12 OUT20
13 OUT5 OUT13 OUT21
14 OUT6 OUT14 OUT22
15 OUT7 OUT15 OUT23
16 OUT8 OUT16 OUT24
res
17 /error res
res
res
18 res
X4: COM / local CAN
Pin 1 CAN_GND
2 TxD
3 CTS
4 24 VN
5 0 VN
6 RxD
7 RTS
8 CAN_H
9 CAN_L
X8: local CAN
Pin 1 CAN_GND
2 res
3 res
4 res
5 res
6 res
7 res
8 CAN_H
9 CAN_L

389
RE 30131/07.05

Hydraulics Bosch Rexroth AG

VT-HNC100

11/12

Unit dimensions (nominal dimensions in mm)


71 (106,5)

192

44 (79)

184

4 x 4,5

X4
X3

PIN4=24VDC

reset

3456

OUT 1-8

analog IN/OUT

3456

1
EF 2

1
EF 2

135
128,4

BC D

BC D

155

X7
S1 8 9 A S28 9 A

shield
GND

X5

111,5

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

IN 1-8

local CAN

X8

encoder

COM / local CAN

RUN
5V CPU

18-36V

X1

X6
X2

HNC100

Vibration damper

02
( ) nominal dimensions are valid for VT-HNC100-2-2X/.-16-.-. and VT-HNC100-1-2X/.-24-.-.

Preferred types
Type

Material number

VT-HNC10012X/W-08-0-0

R900955334

VT-HNC10012X/W-08-I-0

R900955332

VT-HNC10012X/W-08-P-0

R900958999

VT-HNC10012X/W08C0

R900959000

390
12/12

Bosch Rexroth AG

Hydraulics

VT-HNC100

RE 30131/07.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

391
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30050/03.04
Replaces: 11.02

Analog position controller


Type VT-MACAS
Series 1X

Type VT-MACAS

List of contents
Contents
Features
Ordering data
Preferred types
Front panel
Block diagram
Technical data
Additional information
Device dimensions

Features
Page
1
2
2
2
3
4
5
6

Design: Module for snapping onto DIN rails


Actuation of valves with on-board electronics
Enabling input
Open-circuit detection for feedback signal cable
Short-circuit-proof interfaces
Measurement taps on front panel
Deadband compensation can be deactivated
Position: PT1 control
Velocity control possible in conjunction with a speedometer:
PI control
Cylinder area ratio adjustment

2004
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-MACAS

1/6

RE 30050/03.04

02

392

Ordering data
VTHydraulic component
Axis control

M A

=A
I=

Type
Controller

Option
No code
Version with
supply input
Version with
current input

=C
V0 =

Actuation
Analog

Customer version
Catalogue version

=A

Function
Position control

Series
Series 10 to 19

1X =
=S
500 =

Serial numbers for types


Standard version without valve amplifier function

Preferred types (available at short notice)


Material no.

Type VT-MACAS

For valve types

0 811 405 139


0 811 405 140

VT-MACAS-500-10/V0
VT-MACAS-500-10/V0/I

Valves with on-board electronics


Valves with on-board electronics

Front panel

RE 30050/03.04

2/6

VT-MACAS

393

Block diagram with terminal assignment

02

VT-MACAS

3/6

RE 30050/03.04

394

Technical data (For device applications beyond the stated values, please consult us!)
Format/design
Fastening/connection
Temperature range
Power supply
(8), (9)
Current rating
Signal input
VT-MACAS-500-10/V0
(1), (2)
VT-MACAS-500-10/V0/I
Feedback signal
VT-MACAS-500-10/V0
(3), (4)
VT-MACAS-500-10/V0/I
Valve signal
(5), (6), (7)
Deadband compensation
Enable signal (10)
Fault signal (11)
IN POS signal (12)
Ramp ranges
Area ratio adjustment
AK:AR
Feedback signal adjustment
Type of controller
Valve zero
Special features

RE 30050/03.04

(86 x 110 x 95) mm/module


DIN rail/connector + terminals
0 ... 70 C; storage: 20 ... +70 C
UB = 24 Vnom/batt.: 21 ... 40 V DC
Single-phase full wave: 21 ... 28 V DCeff
Max. 200 mA
Uset: 10 V, difference amplifier
Ri = 100 k
Iset: 4 ... 20 mA Rsh = 200
Ufeed: 10 V, difference amplifier
Ri = 100 k
Ifeed: 4 ... 20 mA Rsh = 200
UV = 10 V (max. 10 mA) or
IV = 4 ... 20 mA (average 12 mA)
Can be deactivated,
effective in a range of 4 %
8.5 ... 40 V DC
No fault: 24 Vnom (UB) max. 50 mA
Fault: < 2 V
IN POS: 24 Vnom (UB) max. 50 mA
Not IN POS: < 2 V
I: 0.1 ... 1 s
II: 1 ... 10 s
Min. 1:1; max. 1:4
Zero: 5 ... 10 %
Gain: 50 ... 110 %
Position: PT1
Velocity: PI
5%
Module can be switched from position to velocity control
Position window can be switched over
Measurement taps on front panel
Short-circuit-proof interfaces

4/6

VT-MACAS

395

Additional information
Applications
This controller module enables simple position or velocity
control actions to be effected, in combination with Bosch
Rexroth servo cylinders with analog position measurement
systems (potentiometers). Since the signals are processed in an
analog manner and the module is only equipped with the most
essential features required for performing a control action,

we were able to keep the cost of the drive low. A further


speciality of this module is that it can be switched over internally
(front panel) to velocity control, and there is a version for
voltage interface and a version for current interface, related to
the setpoints and feedback signals.

Position control
The setpoint and feedback signals of the position are compared
and the difference transmitted to the valve amplifier. In the event
of an abrupt change in the input signal, the system reacts with
maximum dynamics. The times for accelerating or braking a load

are limited either by the available power or the system gain.


When a ramp function acts as an input value, the load is moved
at a constant speed.

02

Velocity control*
The setpoint and feedback signal of velocity are compared and
the difference transmitted to the valve amplifier. Through the
process of integration, the signal is amplified to such an extent
that even the smallest error is eliminated.

VT-MACAS

When a ramp function acts as an input signal, progressive


acceleration or deceleration with a constant value takes place.
* Only possible with a speedometer.

5/6

RE 30050/03.04

396

Device dimensions (in mm)

Wall mounting

86 x 110 x 95

DIN rail mounting

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30050/03.04

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

6/6

VT-MACAS

397

Digital positioning card for positiondependent braking

RE 30144/09.04
Replaces: 06.03

Type HACD-B

Component series 1X

H7190

Table of contents
Contents

Page

Features

Ordering code

Functional description

2 and 3

Block circuit diagram

Technical data

Pin assignment of the male connector

Pin assignment of the D-sub socket on the front panel

Unit dimensions

Engineering / maintenance notes / supplementary functions

1/8

398
2/8

Bosch Rexroth AG

Industrial Hydraulics

HACD-B

RE 30144/09.04

Features
Position-dependent braking of a hydraulic axis

Accessories required:

Preselection of the target position possible via analogue


input or internal parameter

PC program BODAC: Ordering code of the CD:


SYSHACDBODAC01 (mat. no. R900777335) or download on the Internet at: www.boschrexroth.com/hacd

Preselection of traversing speed possible via analogue input


or internal parameter
Actual value acquisition possible by means of SSI encoder
or analogue position measuring system

Interface cable: Cable set VTHACD1X/03.0/HACD-PC


(mat. no. R900776897) or commercial 1:1 cable
Further information:

Adjustable start-up ramp with rounding option (S-components)

Installation instructions for HACD-B, see RE 30144-B

Adjustable emergency ramp for stopping a movement

Operating instructions for BODAC and commissioning


instructions for HACD included in the BODAC program
package, see RE 30144-01-B

Braking characteristics can be set to linear or root-shaped


Residual speed logic with shutdown in the target window or
permanent activation for traversing to the mechanical limit
stop
Overlap compensation for valves with positive overlap

Suitable card holders


19 rack types VT 19101, VT 19102, VT 19103 and VT 19110
(see RE 29768)
Enclosed card holder type VT 12302 (see RE 30103)

Traversing profile can be adjusted separately for A->B and


B->A
Set-up operating mode with separate preselection of traversing speed and residual speed

Open card holder type VT 3002-2X/64G (see RE 29928)


Only for installation in a control cabinet!
Connection adapter type VT 10812-2X/64G (see RE 30105)

Start A->B or B->A via digital input

Suitable power supply unit

Activation of set-up mode via digital input

Compact power supply unit type VT-NE30 (see RE 29929)

Switching outputs for position A and B reached


Enable input and OK output
10 V reference voltage output
Front display with keys for displaying and changing parameters as well as for diagnosis purposes
RS232 serial interface

Ordering code
VTHACDB

1X V0

Digital controller card

0=

Component series 10 to 19
= 1X
(10 to 19: unchanged installation and connection dimensions)
Basic unit

0=
1=

Without valve output stage


Without bus interfacing
With display

= V0

Functional description
The HACD-B digital positioning card for position-dependent braking is designed as double-sided printed circuit board in Euro-format 100 x 160 mm.
A microcontroller controls the entire sequence. Card-specific data (configuration and parameters) are saved in a non-volatile
memory.
The card is completely configured by means of software and does not include any jumpers or similar items. For the purpose of
configuration, the HACD-B must be connected to a PC via a serial interface (RS 232, 1:1 cable). The configuration as well as parameterisation and diagnosis are carried out by means of the BODAC user interface.
Alternatively, parameterisation and diagnosis can also be carried out with the help of the 4 keys and the display on the front panel.
The parameters for target position, traversing speed, braking and residual speed can be selected separately for the directions
A->B and B->A.

399
RE 30144/09.04

Industrial Hydraulics Bosch Rexroth AG

HACD-B

3/8

Functional description (continuation)


The movements A->B or B->A are started via switching inputs.
The switching inputs signal that target position A or B has been reached within an adjustable target window.
v [%]
Velocity

100
Linear or
root-shaped

vmax

Residual
speed
S-ramp
start

Ramp S-ramp
end

Emergency Start of
ramp
braking

Target position

Position s
[Units]

Target position

Troubleshooting

The target position can be fed forward either via the analogue
input or set by means of internal parameters.

The following faults are signalled by a high level at switching


output DO7:

Traversing speed

Monitoring of the analogue inputs for falling below or exceeding certain ranges in accordance with the set limits.

The traversing speed, too, can be fed forward via the analogue
input or by means of internal parameters. A downstream ramp
generator with rounding option for the start and end of the
ramp allows jerk-free acceleration of the drive. An adjustable
emergency ramp allows smooth stopping of the drive when the
start signal is withdrawn.
Braking
The time of braking is to be given as internal parameter. It is
to be entered as distance to the target position referred to a
speed of 100%. The braking characteristics can be linear or
root-shaped.
Residual speed

Monitoring of the SSI encoder for cable break


Valve monitoring (comparison of command/actual)
The following faults result in a stop (analogue output d30 = 0):
Monitoring of the supply voltage, all internal voltages as well
as the 10V reference voltage.
Monitoring of the microcontroller itself (watchdog) as well as
of the memory (checksum)
Front panel operation
In conjunction with the 4 keys, the front display serves for displaying and changing parameters as well as for diagnosis purposes.

The residual speed logic allows both, traversing at creep speed


to the target position or traversing to the mechanical limit stop.
When traversing to the target position was selected, the residual speed is switched off within an adjustable target window.
When traversing to limit stop was selected, the active residual
speed is maintained.

Access to the parameters of the HACD-B is provided by a corresponding menu structure. The parameter values can be displayed and changed.

Moreover, it is possible to compensate for the characteristics


of valves with positive overlap with the help of the overlap compensation feature.

Speed, including ramp times, A->B and B->A

Set-up operating mode

Configuration of analogue I/O

The set-up mode can be activated using the set-up switching input.

Configuration of SSI

In this operating state, separate, internal parameters are used


for the traversing speed. Feedforwarding via an analogue input
is impossible.
Moreover, it is possible to parameterise a residual speed.

The following parameters can be accessed:


Target position A and B
Start of braking, A->B and B->A
Residual speed, A->B and B->A

Changes to the configuration, e.g. braking characteristics and


the use of analogue inputs or internal parameters are possible
by front panel operation.
The diagnosis options include the display of command and actual values as well as the output of fault messages.
PC program BODAC
The PC program BODAC allows the configuration, parameterisation and diagnosis of the HACD-B via a serial interface (RS
232).

02

b6

d2
d4

d6
d8

Start A -> B

Start B -> A

0V

Actual valve
value
+ UO

z32

z30

DC

Speed A -> B

Speed B -> A

DC

SSI/analogue

A/B

A/B

A/B

Characteristics

A->B

B->A

Start-up and emergency ramp

A->B

B->A

Braking

A->B

Target position B

A/B

MIN

A/B

Residual speed with


and without stop

A->B

B->A

Fault
detection

U
U/I

b30
b32

f2

d22

z28

z24

z22

d26

d20

d30

10 V
+ 10 V

Collective
fault

System deviation of
valve
OK

Set-up active

Position B
reached
Emergency
ramp active

Position A
reached

AO 1

Industrial Hydraulics

b22
U/I
b24

d18

d10
d12

Enable

U/I

U/I

b2
U/I
b4
U

f10

f8

f4
f6

Set-up

Speed

DATA

DATA+

CLK+
CLK

Actual position b10


(analogue) b12

Target position b8

B->A

Target position A

Bosch Rexroth AG

Actual positition(digital)

4/8

400
HACD-B
RE 30144/09.04

Block circuit diagram: VT-HACD-B

401
RE 30144/09.04

Industrial Hydraulics Bosch Rexroth AG

HACD-B

5/8

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC + 40 % 10 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 21 V
Imax 150 mA

Current consumption
Fuse

IS 4 AT

Digital inputs

U log 0 = 0 to 5 V
log 1 = 15 V to UO

Digital outputs

U log 0 = 0 to 5 V
log 1 = 15 V to UO
Imax = 30 mA

Analogue inputs
Configuration as voltage input
Range

U 0 to 10 V or 10 V (configurable)

Input resistance

Ri 100 k, > 10 M for input AI 3

Resolution

5 mV for range 10 V, 2.5 mV for range 0...10

Non-linearity

< 10 mV

Configuration as current input


Range

0...20 mA or 4...20 mA (configurable)

Input resistance

U 100

Current loss

Ri 0.5 % (with 500 between pin AI x and 0 V)

Resolution

5 A

Analogue outputs

02

AO 1 configuration as voltage output


Output voltage

U 0 ... 10V or 10 V (configurable)


Imax 20 mA load Rmin 500

Output current
Resolution

1.25 mV (14 bits)

Residual ripple content

15 mV (without noise)

AO 1 configuration as current output


Output current

U 0...20 mA or 4...20 mA (configurable)


Rmax 500

Load
Resolution

1.25 A

Residual ripple content

15 A (without noise)

Reference voltage

U 10 V
Imax 30 mA
Residual ripple content < 20 mV

Scanning rate
Ramp time

T 2 ms
tmax 300 s

Serial interface

RS 232 (front panel), D-sub socket

Type of connection

64-pin male connector, DIN 41 612, form G

Card dimensions

Euro-card 100 x 160 mm, DIN 41 494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side


Permissible operating temperature range
Storage temperature range
Weight
Note:

7 TE
0 to 50 C
20 to + 70 C
m 0.2 kg

For details regarding environment simulation testing in the fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 30143-U (declration on environmental compatibility).

402
6/8

Bosch Rexroth AG

Industrial Hydraulics

HACD-B

RE 30144/09.04

Pin assignment of male connector


Pin

Row z

Row b

Row d
1)

n.c.

Speed

n.c.

Speed 1)

6
8

n.c.
n.c.

Target position +
Target position

1)

1)

Row f

Start A -> B

4)

Collective fault

Start A -> B

4)

Actual value SSI clock pulse +

Start A -> B

5)

Actual value SSI clock pulse

Start A -> B

5)

Actual value SSI data +

10

Shield

Actual value, analogue +

3)

6)

12

n.c.

Actual value, analogue

3)

14

n.c.

n.c.

n.c.

n.c.

16

n.c.

n.c.

n.c.

n.c.

Set-up

Set-up 6)

Actual value SSI data


n.c.

18

n.c.

n.c.

Enable

n.c.

20

System ground

n.c.

Position A reached

n.c.

22

Emergency ramp active

Actual valve value +

OK

n.c.

24

Set-up active

Actual valve value

n.c.

n.c.

26

n.c.

n.c.

Position B reached

n.c.

28

System deviation, valve

Analogue GND

n.c.

n.c.

30

UO: + 24 V

Reference voltage 10 V

Analogue output AO 1 2)

n.c.

32

L0: 0 V

Reference voltage +10 V

n.c.

n.c.

1)

The inputs can be set to 0...10 V, 10 V or 4...20 mA by


means of software.

2)

Output AO 1 can be set to 0...10 V, 10 V or 4...20 mA by


means of software.

3)

This input has an input resistance of Ri > 10 M.

4) 5) 6)

n.c. ... not assigned in the basic version, but reserved for extensions.

The two inputs must be connected

Pin assignment of D-sub socket on the front panel

5
9

GND

Send data (RS 232)


Receive data (RS 232)
6
1

403
7/8

Industrial Hydraulics Bosch Rexroth AG

HACD-B

RE 30144/09.04

Unit dimensions (dimensions in mm)

UP
DOWN

100

3HE (128,4)

ESC

X1 X2

I1
I2
I3
I4
I5
I6
I7
I8

122

ENT

89

OK

O1
O2
O3
O4
O5
O6
O7

8TE (40,3)

165

195,5

Engineering / maintenance notes / supplementary functions


Use low-capacitance cables. Whenever possible, establish cable connections without intermediate terminals.
The arrangement of electromagnetic sources of interference (e.g. frequency converter) in the direct vicinity of the closed-loop
control electronics is not permitted.
Do not lay power cables in the direct vicinity of the controller card.
Do not lay cables of the control electronics in the direct vicinity of power cables.
Lay sensor cables separately.
The distance to aerial lines, radio sources and radar equipment must be at least 1 metre.
Engineer the system so that when the differential inputs are used, both inputs are always activated or deactivated simultaneously.
Use relays with gold-plated contacts for passing on command values (small voltages, small currents).
Always shield command value and actual value cables. Connect the shield to shield on the card side and leave the other end
open, otherwise, there is a risk of earth loops.
Use highly flexible CU conductors (min 2.5 mm2) for connecting the system ground!
The system ground is an essential part of EMC protection of the controller card. It discharges interference that is transported
via data and supply voltage cables to the controller card. This function can only be ensured, if the system ground itself does not
inject interference into the controller card. Rexroth recommends that solenoid cables be shielded as well.
Electrical signals brought out via control electronics (e.g. the OK signal) must not be used for switching safety-relevant machine functions!
(See also European Standard Safety requirements for fluid power systems and components - hydraulics EN982:1996)

02

404
8/8

Bosch Rexroth AG

Industrial Hydraulics

HACD-B

RE 30144/09.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

405

RE 30 141/09.02
Replaces: 08.00

H/A/D 6208/99

Digital control system assembly HNC100-SEK


for the secondary control of axial piston
units
Type SYHNC100-SEK
Series 2X

Type SYHNC100-SEK-2X/.-24-

Overview of contents
Contents

Page

Features
Ordering details
Software engineering
Technical data
Block circuit diagram

Contents

Page

System overview
Connection allocation
Unit dimensions
Engineering / maintenance guidelines /
additional information

1
2
2
3 and 4
5

6
7
8

02
8

Features
The digital HNC100-SEK control system is suitable for the closed loop
control of speed and torque and the open loop control of torque for
secondary controlled axial piston pumps type A4VS..DS1(E). It has
interfaces for the acquisition of swivel angle position for single or tandem
units as well as RPM feedback using incremental transducers. The
sorftware contains open and closed loop control and monitoring functions
which are specifically laid out for the secondary control.
Compact unit for panel mounting, optionally available as a
19" rack plug-in unit
Permanent storage of system parameters in an
EEPROM
Parameterisation and process visualisation via a commercially
available PC
Two modules with monitoring functions for the evaluation of
signals from inductive swivel angle transducers
4 analogue differential input (voltage or current)
4 impedance convertor inputs
2 incremental transducer inputs with monitoring functions for
RPM or angle of rotation acquisition

4 analogue voltage outputs 10 V, two of them optional


as current outputs
24 digital inputs
Profibus DP, CANopen or INTERBUS-S for communication
with a PLC (CANopen/INTERBUS-S with restrictions)
24 digital outputs (switched outputs)
Configured sequence routine for on/off switching sequences
with the control of an isolator valve and brake if fitted
Monitoring functions with output of fault codes for improved
diagnostics
Conformity with the relevant EU directives (CE sign)

Notes regarding system build-up:


With secondary units fitted with a servo valve type 4WS2EM10
(standard version, see RE 92 055) an additional amplifier module
type VT 11 021 (see RE 29 743) is required.
Alternatively: Use a servo valve type 4WSE2EM10 with
intergrated electronics or a control valve
(consult us)

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

SYHNC 100-SEK

1/8

RE 30 141/09.02

406

Ordering details
SYHNC100 SEK 2X /

24

E24

*
Further details in clear text

Digital NC control HNC100


Version for secondary control

= SEK

Series 20 to 29
(20 to 29: unchanged technical data and
connection allocation)

A037 =
A038 =
A039 =
A040 =

= 2X

Installation type:
Housing for wall mounting
Housing for rack mounting

E24 =
=W
=M

24 digital inputs/outputs

= 24

Without bus connection


Profibus DP 1)
Only on request:
CANopen
INTERBUS-S
1)

= 0
= P
= C
= I

Standard software version:


Closed loop RPM control
Closed loop master/slave RPM control
Torque control
Closed loop torque control
Hydro-static drives

Evaluation electronics for the


inductive position transducer:
Without evaluation electronics
Evaluation electronics for position transducer
type IW9, stroke 9 mm (standard)

0=
C=

On request:
Evaluation electronics for the position transducer DPH
Evaluation electronics are not possible
in conjuntion with INTERBUS-S and CANopen

Additional plug type 6ES7972-0BA20-0XA0 for Profibus DP is


not included within the scope of supply and must be ordered
separately!
Material No.: 00050152

Ordering details for accessories:

KABELSATZ

VT 15 300 1X /

Connection cable for connecting a PC


to the digital NC control HNC100-SEK
Series 10 to 19
(10 to 19: unchanged technical data and connection allocation)

/ *
Further details in clear text

= 1X

02,0 =
03,0 =
04,0 =
05,0 =
10,0 =
15,0 =

Cable length in m

Software engineering
The PC programme WIN-PED is available for setting and
documenting the control parameters and the display of condition
values on a PC.
Scope of functions:
Dialogue window for on-line or off-line setting of the
parameter values
Comprehensive options for displaying process variables, the
digital inputs, outputs and flags
Recording and graphical represenation of up to four process
variables via selection of trigger options
System requirements:
IBM PC or compatible system
Windows 3.1 or Windows 95
Processor Intel 80286 or higher (recommendation 80486 or
better)
Min. 8 MB RAM (recommendation 16 MB)
10 MB free hard disc space
RE 30 141/09.02

Note:
PC programme WIN-PED (SYS-HNC-WINPED-.01) is not included
within the scope of supply and must be ordered separately!
Material No.:00887807 SYS-HNC-WINPED-C01 (CD-ROM)
On request SYS-HNC-WINPED-D01 (discs)

2/8

SYHNC 100-SEK

407

Technical data (for applications outside these parameters, please consult us!)
Operating voltage
Power consumption

UB
Pinternal

Processor

18 to 36 VDC
8 W (in addition power for any connected sensors/actuators)
16/32 Bit MC68376

Memory

Flash-EPROM 1 MB; EEPROM 8 KB; RAM 256 KB (main memory)


1):

Analogue inputs
Voltage input (differential input)
Number of channels
Input voltage
Input resistance
Resolution
Non-linearity
Calibration tolerance 2)
Current input
Number of channels
Input current
Input resistance
Resistance between output pin and GND
Current loss
Resolution
Impedance input 3) 4)
Number of channels
Input voltage
Input resistance
Resolution
Non-linearity
Calibration tolerance 2)

UE
RE

IE
RE
R
IV

Uimp
Rimp

Analogue outputs:
Number of channels
Voltage and current output
Voltage output
Output voltage
Unom
Output current
Imax
Load
Rmin
Output current (current driver only)
Inom
Load (current driver only)
Rmax
Residual ripple
Resolution
Non-linearity
Within the range 9.5 V to + 9.5 V
Within the range 10 V to 9.5 V and + 9.5 V to + 10 V
Serial interfaces

Standard
Optional

4
Max. + 15 V to 15 V (+ 10 V to 10 V can be measured)
200 k 2 %
5 mV
< 10 mV
Max. 40 mV (with factory calibration)
4
0 to 20 mA
100 0.2 %
0 to 500
0.1 to 0.4 % (for 500 at output pin)
5 A
4
10 V to + 10 V
> 10 M
5 mV
< 10 mV
Max. 40 mV (with factory calibration)

02

2
2
10 V to + 10 V (max. 10.7 V to + 10.7 V)
10 mA
1 k
20 mA to + 20 mA (max. 23 mA to + 23 mA)
500
60 mV (without noise)
1.25 mV
15 mV
35 mV
RS232 (9.6 KBaud)
Profibus DP (max. 12 MBaud); CANopen; INTERBUS-S

Signal inputs

Number
Logic level
Connection

24
Log 0 (low) 5 V; log 1 (high) 10 V to UB; Re = 3 k 10 %
Flexible conductor up to 1.5 mm2

Signal outputs

Number
Logic level
Connection

24 (short circuit proof)


Log 0 (low) 2 V; log 1 (high) UB; Imax = 50 mA
Flexible conductor up to 1.5 mm2

1)

2)

Not all of the channels can be driven simultaneously. The voltage


inputs and the current inputs are provided with a common pin so
that either the voltage input or the current input can be used.
If the factory settings are not sufficient, the measuring instruments
can be calibrated on site according to the system requirements.

3)

4)

Due to the characteristics of these high resistance inputs, internal


protective circuits with diodes or capacitors cannot be used.
For this reason, when applying analogue signals to inputs Uimp1
to Uimp4, all the required protective features such as shields, EMC
protection and signal filtration must be connected externally in
the incoming circuit.
When using evaluation electronics for the inductive position
transducer only 2 impedance inputs are available.

Continued on next page


SYHNC 100-SEK

3/8

RE 30 141/09.02

408

Technical data - continued (for applications outside these parameters, please consult us!)
Digial position transducers:
Incremental transducer
Transducer with TTL output
Input voltage
Input current
Sensor with an HTL output
Input voltage
Input current

Power supplied by the HNC100 to the position transducers


Max. voltage for all input signals

Log 0
Log 1
Log 0
Log 1

0 to 1 V
2.8 to 5.5 V
0.8 mA (at 0 V)
0.8 mA (at 5 V)

Log 0
Log 1
Log 0
Log 1

0 to 2.8 V
21 to 35 V
0.8 mA (at 0 V)
8.8 mA (at 35 V)

U
Umax

Inductive position transducers:


Number
Voltage supply

Ueff

Reference voltage

Uref

Dimensions (W x H x D)

UB or + 5 VDC 5 %; max. 200 mA


UB 1 V (signals are not opto-decoupled)
2
2 V (Imax = 30 mA / channel)
Balanced to ground, short circuit proof, can be synchronised
between 4.8 and 5.2 kHz, optional compensation capacitor of
220 nF; amplitude constant 0.2 % /10 K; carrier frequency
5 kHz 2 %; inductive transducers in half and full bridge circuit
and 3 and 4 conductor circuit; linearity error < 0.1 %
+ 10 V 25 mV; 20 mA and
10 V 25 mV; 20 mA
106.5 x 155 x 204 mm

Permissible operating temperature range


Storage temperature range

0 to 50 C
20 to + 70 C

Weight

1.2 kg

Further technical details on request.

Note:
For details regarding the environmental simulation test covering
EMC (electro-magnetic compatibility), climate and mechanical stress,
see RE 30 131-U (declaration on environmental compatibility).

RE 30 141/09.02

4/8

SYHNC 100-SEK

SYHNC 100-SEK

5/8

ncommand

2 analogue
outputs

5 free
analogue
inputs

22 digital
outputs

24 digital
inputs

WIN-PED

PC

RS232

RPM
n controller

Power
limitation

Additional
functions

Controller
programme
Swivel
angle
controller 2

RPM
calculation

Swivel
angle
controller 1

Control and monitoring programme

Communication

Counter
and
monitoring

Pos. transducer
evaluation 1
and
monitoring

Pos. transducer
evaluation 2
and
monitoring

Counter
and
monitoring

Amplifier VT 11021
or
integr. electronics

Tandem unit (optional)

Amplifier VT 11021
or
integr. electronics

Optional

p0

p0

X Relay, PLC or
switching amplifier

p0

p0

Emmergency OFF
circuit system side
(24 V; 2 x 25 W)

409

Block circuit diagram

RE 30 141/09.02

02

410

System overview
Higher level control
Possible interfaces to the HNC100:
Analogue signals
Digital inputs / outputs
Serial interface
Field bus system Profibus DP
(on request CANopen, INTERBUS-S)

7
X4
PIN4=24VDC
COM / local CAN

encoder

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

X7
345 6

S2

9
78 A

BC D

BC D

9
78 A

345 6

S1

1
EF 2

X7

reset
IN 1-8

1
EF 2

X1.1

local CAN

X8

X3

analog IN/OUT

X3

RUN
5V CPU

X1.1
shield
GND
18-36V

X2

IN 9-16

IN 17-24

9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
res
res

17
18
19
20
21
22
23
24
17
18
19
20
21
22
23
24
res
res

X5
OUT 1-8

X6
X2

HNC100

X1.1

OUT 9-16 OUT 17-24

X1.2

X1.3

8
2
X4

1
local CAN

X8

8
1
2
3
4
5
6

Secondary unit A4VS


Position transducer IW9
Servo valve
Sandwich plate filter
Incremental transducer
Electrically pilot operated check valve
(with plug-in switching amplifier VT-SSV-1)

RE 30 141/09.02

COM / local CAN

PIN4=24VDC

HNC100

Additional
SYHNC100-SEK

7 SYHNC100-SEK
8 Local CAN-Bus
9 Connecting cable
6/8

SYHNC 100-SEK

411

Connection allocation
X8: Local CAN
Pin 1
CAN_GND
2
res
3
res
4
res
5
res
6
res
7
res
8
CAN_H
9
CAN_L

X4: COM / local CAN


Pin 1
CAN_GND
2
TxD
3
CTS
4
24 VN
5
0 VN
6
RxD
7
RTS
8
CAN_H
9
CAN_L

X4
PIN4=24VDC
COM / local CAN

RUN
5V CPU

reset
IN 1-8

encoder

local CAN

X8

X3

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

X7
9
78 A

analog IN/OUT

3 45 6

S2

BC D

BC D

9
78 A

3 45 6

S1

1
EF 2

S1, S2 Address, Baud rate CAN

1
EF 2

shield
GND
18-36V

IN 9-16

IN 17-24

9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
res
res

17
18
19
20
21
22
23
24
17
18
19
20
21
22
23
24
res
res

X5
OUT 1-8

X6

HNC100
X5:
Pin
1
2
3
4
5
6
7
8
9

Profibus DP
n.c.
n.c.
RxD / TxD-P
CNTR-P
DGND
VP
n.c.
RxD / TxD-N
n.c.

INTERBUS-S (OUT)
+ DO 2
+ DI 2
GND 2
n.c.
Udd
DO 2
DI 2
n.c.
BCI

X7:
Pin
1
2
3
4
5
6
7
8
9

Inductive IW9
IW9_1:
IW9_1: 2
IW9_1: 1
res
IW9_2:
IW9_2: 2
IW9_2: 1
res
res

Inductive
Supply 1 +
Supply 1
Signal 1 +
Signal 1
Supply 2 +
Supply 2
Signal 2 +
Signal 2
Sync IN/OUT

SYHNC 100-SEK

CANopen
n.c.
CAN_L
CAN_GND
n.c.
n.c.
n.c.
CAN_H
n.c.
n.c.

X2

X1.1

X6: Voltage supply


Pin 1
Shield
2
GND
3
18 - 36 VDC

INTERBUS-S (IN)
+ DO1
+ DI1
GND1
n.c.
n.c.
DO1
DI1
n.c.
n.c.
7/8

OUT 9-16

X1.2

OUT 17-24

X1.3

X3: Encoder
Pin
Incremental
1
/Ua 2
2
Ub 2
3
Ua 0
4
/Ua 0
5
Ua 1
6
/Ua 1
7
/Ub 2
8
Ua 2
9
/Ub 1
10
0 VN
11
Ub 1
12
5 VTTL (max. 200 mA)
13
Ub 0
14
24 VN (max. 450 mA)
15
/Ub 0
X1.1 to X1.3: Digital IN/OUT
Pin X1.1 X1.2 X1.3
1 IN1
IN9
IN17
2 IN2
IN10 IN18
3 IN3
IN11 IN19
4 IN4
IN12 IN20
5 IN5
IN13 IN21
6 IN6
IN14 IN22
7 IN7
IN15 IN23
8 IN8
IN16 IN24
9 OUT1 OUT9 OUT17
10 OUT2 OUT10 OUT18
11 OUT3 OUT11 OUT19
12 OUT4 OUT12 OUT20
13 OUT5 OUT13 OUT21
14 OUT6 OUT14 OUT22
15 OUT7 OUT15 OUT23
16 OUT8 OUT16 OUT24
17 /error res
res
18 res
res
res

X2: Analogue IN/OUT


Iin 1
Pin 1 Uin 1 +
2 Uin 1
3 Uin 2 +
Iin 2
4 Uin 2
5 Uin 3 +
Iin 3
6 Uin 3
Iin 4
7 Uin 4 +
8 Uin 4
9 Iout 2
10 Uout 2
11 analogue_GND
12 Uref = + 10 V
13 Uref = 10 V
14 Iout 1
15 Uout 1
16 Uout 3
17 Uout 4
18
Iin 1 +
19
Iin 2 +
20
Iin 3 +
21
Iin 4 +
22 Uimp 1
23 Uimp 2
24 Uimp 3 (only without evaluation electronics)
25 Uimp 4 (only without evaluation electronics)
RE 30 141/09.02

02

412

Unit dimensions (dimensions in mm)


192

106,5
79

4 x 4,5

184

X4
COM / local CAN

RUN
5V CPU

reset
IN 1-8

encoder

local CAN

X8

X3

1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
err
res

3 45 6

analog IN/OUT

3 45 6

1
EF 2

135

9
78 A

1
EF 2

128,4

S2

BC D

9
78 A

BC D

155

X7
S1

shield
GND
18-36V

IN 9-16

IN 17-24

9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
res
res

17
18
19
20
21
22
23
24
17
18
19
20
21
22
23
24
res
res

111,5

PIN4=24VDC

X5
OUT 1-8

X6

HNC100

X2

X1.1

OUT 9-16 OUT 17-24

X1.2

X1.3

Vibration dampers

Engineering / maintenance guidelines / additional information


Place of installation
Do not install the HNC100 next to power electronics (e.g. frequency
convertors); the power supply unit of the HNC100 should be installed
as close as possible to the HNC100.
Voltage supply
The connection should be as short as possible, lay the supply and
return lines (+ 24 V / GND) together.
Operating voltage range: 18 to 36 V (ripple < 1.5 V; 0,9 mA)
Input fuse:
1.25 A (recommendation)
When providing the power supply to an inductive position transducer
via the interface of the HNC100, the supplied voltage must meet the
requirements of the position transducer.
Earthing of the housing
The housing of the HNC100 is earthed via the connection of the
fixing screws with the rear panel of the switching cabinet.
Screening
Always use cables with screens made of copper braid for signal lines.
Typically, the screen is connected at one end to the HNC100. Connect
a large area of the cable screen to the metal part of the plug connector
housing (push the screen back and clamp the cable while it is stress
relieved).

Wiring
The distance between the signal and load lines should be as
large as possible
Do not route signal lines through strong magnetic fields
Lay signal lines without interruptions
Twist together load lines (e.g. supply voltage), which are laid as
two single cores,
Do not lay signal lines in parallel to load lines
System interference suppression
Switched inductivity:
DC Anti-parallel free wheeling diode via consumer
winding
AC Type related R/C combination via consumer winding
Electric motors:
Connect R/C combinations from each motor winding to earth
Frequency convertor:
Provide an input filter in the power supply of the frequency
convertor
Shield control lines of the motor and install them separately
from other lines and/or provide output filters for motor lines
Large area contact of the frequency convertor housing with
the back panel of the switching cabinet

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
E-mail: info@boschrexroth.co.uk

RE 30 141/09.02

8/8

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application can
be derived from our information. The details stated
do not release you from the responsibility for
carrying out your own assessment and verification.
It must be remembered that our products are
subject to a natural process of wear and ageing.

SYHNC 100-SEK

413

RE 30143/05.05
Replaces: 08.03

Digital command value


and controller card

Type VT-HACD-1

Component series 1X

H7344_d

Table of contents
Contents

Page

Features

Ordering code

Functional description

3 and 4

Block circuit diagram: VT-HACD-1, mode 1 - block call-ups

Block circuit diagram: VT-HACD-1, mode 2 - motion profile

Block circuit diagram: VT-HACD-1, mode 3 - structure editor

Technical data
Pin assignment of the male connector

8 and 9
9

Pin assignment of the D-Sub sockets on the front panel

10

Unit dimensions

10

Engineering / maintenance notes / supplementary information 11

Information on available spare parts:


www.boschrexroth.com/spc

1/12

414
2/12

Bosch Rexroth AG

Hydraulics

VT-HACD-1

RE 30143/05.05

Features
Required accessories:

Use as command value card for generating, linking and


normalizing signals

PC program BODAC:
Ordering code of CD: SYSHACDBODAC01
or download on the Internet
www.boschrexroth.com/hacd

Use as controller card for closed control loops with PIDT1controller and optional state feedback
Alternating closed-loop control (e.g. position control with
superimposed pressure / force control) possible

Interface cable: Cable set VTHACD1X/03.0/HACD-PC or


commercial 1:1 cable

Input for digital measuring system, SSI and incremental


6 analog inputs, can be switched between voltage (10 V,
0...10 V) and current (4...20 mA)

Optional USB adapter VT-ZKO-USB/S-1-1X/V0/0

Analog outputs, 1x can be changed between voltage


(10 V, 0...10 V) or current (0...20 mA, 4...20 mA),
1x voltage (10 V)

Further information:
Installation instructions for VT-HACD, see RE 30143-B
Operating instructions for BODAC and commissioning of
HACD-1 (included in the BODAC program package),
see RE 30143-01-B

Versatile options of signal connection and change-over


Enable input and OK output
8 digital inputs
7 digital outputs, can be configured

Suitable card holders

Parameterisable ramp function

19 rack types VT 19101, VT 19102, VT 19103 and VT 19110


(see RE 29768)

32 blocks with command values, velocities and controller


parameters

Enclosed card holder VT 12302-3X (see RE 30103)

Adjustment to hydraulic drives by means of area adjustment, characteristic curve correction, overlap compensation,
residual velocity logic and zero point correction

Open card holder VT 3002-2X/64G (see RE 29928)


For control cabinet installation only!
Connection adapter VT 10812-2X/64G (see RE 30105)

10 V reference voltage output


Front display with keys for displaying and changing parameters as well as for diagnosis
Serial interface RS232
Configurable analog output (A03) connected to plug connector

Ordering code
VT-HACD

1X V0

Digital command value and controller card


Standard command value and controller card
Series 10 to 19
(10 to 19: unchanged technical data and
pin assignment)

0=
=1

0=
P=

= 1X
1=
V0 =

Without valve output stage


Without bus interfacing
Profibus DP V0
With display
Basic device

415
RE 30143/05.05

Hydraulics Bosch Rexroth AG

VT-HACD-1

3/12

Functional description
The VT-HACD command value and controller card is a doublesided printed circuit board in Euro-card format 100 x 160 mm.
A microcontroller controls the entire sequence, makes adjustments and connections and realises closed control loops.
Card-specific data (configuration and parameters) are saved in
a non-volatile memory.
The card is completely configured by means of software; it
does not include any jumpers or similar components. For the
purpose of configuration, the VT-HACD must be connected to
a PC via a serial interface (RS 232, 1:1 cable). The complete
configuration as well as parameterisation and diagnosis are
handled with the user interface BODAC.
The configuration and thus the realisation of applications is
very easy by linking pre-defined function blocks. This does not
require any programming knowledge:
Mode 1 - Block call-up (factory setting)
The 32 blocks can be called up via the binary combination of
digital inputs DI1DI5 + DI6 as binary enable. This mode
is compatible with VT-SWKD in terms of functions.
Mode 2 - Motion profile
A command value profile is provided that images a typical
application of a closed-loop position control.
Mode 3 - Structure editor
The structure editor is enabled. It is possible to create own
motion sequences. 32 blocks are available to this end.
Each block comprises the following: Command value, ramp
times (velocity+, velocity-, S-component) and controller
parameters.
Blocks are activated by setting trigger conditions: Setting
of digital inputs, comparison of signals with freely definable
thresholds, or elapsing of waiting times.
Changing over to another mode is possible by saving a corresponding parameter set, which is included in the scope of supply of BODAC.
Signal linkage
The VT-HACD offers versatile options of signal linkage [8] and
[9] on both, the input and output side, with 2 signals being
able to be linked. The possible functions are addition, subtraction, multiplication and division as well as minimum / maximum
value generator, area ratio and limiter:

Analogue I/O
The 6 analogue inputs can be changed between 10V, 0
10V, 020mA and 420mA by means of software.
One analogue output can also be switched between 10V,
010V, 020mA and 420mA by means of software. The
2nd analogue output is permanently set to 10V. A03 can be
configured with the help of software and can be used, for example, for diagnosis purposes.
Changing over is executed so that the entire range of the
analogue/digital converter is utilised.
The operating range as well as fault recognition can be defined
for all analogue inputs.
The analogue outputs can be adjusted by means of gain and
offset.
Digital I/O
The VT-HACD is provided with 9 digital inputs and 8 digital
outputs.
One input has the fixed functionality enable, one digital output the fixed functionality OK.
The other digital inputs are used for triggering blocks (see
blocks and triggering).
The function of each digital output can be assigned by selection from a pre-defined list:
Command value = actual value
Actual value greater than or less than an adjustable threshold
Waiting time elapsed
Ramp active
Internal flag set
Error flag set
Digital position measuring system
When the VT-HACD is used as controller card, digital SSI or
incremental position measuring systems may be used for the
acquisition of actual values.
Performance limits of incremental encoders

= subtraction: Z = X - Y

The maximum frequency of the incremental encoder input (FE)


of the VT-HACD is 100 kHz. The decisive factors for the frequency are the maximum operating speed of the drive, the resolution (Res) of the encoder system used and possible signal
evaluation by an EXE (interpolation and digitisation electronics).

* = multiplication: Z = X * Y / 100

Determination formulas

/ = division: Z = X / Y * 100

Encoder resolution at given maximum velocity:

+ = addition: Z = X + Y

MIN = minimum value generator: Z = MIN (X, Y)


MAX = maximum value generator: Z = MAX (X, Y)
RATIO = Input of a ratio:
for RATIO >1: Z = X * RATIO - Y
for RATIO <1: Z = X - Y / RATIO
(e.g. area ratio for differential pressure measurement)
LIMIT = signal limiter: Z = MIN (|X|, |Y|) * X / |X|
JUMP = step function generator: Z = MAX (|X|, |Y|) * X / |X|
with

Z ... result
X ... 1st signal
Y ... 2nd signal

Res [m]

3
v m
s x 10
Fa [kHz] x EXE

Velocity at given encoder resolution:


Res [m] x EXE x FE [kHz]
v m
s
103

02

416
4/12

Bosch Rexroth AG

Hydraulics

VT-HACD-1

RE 30143/05.05

Functional description (continued)


Controller

Fault detection and correction

If the VT-HACD is used as controller card, the entry controller


must be selected in signal linkage [8].

The VT-HACD supports many fault monitoring options:

LCx signals represent the command value branch, LFBx signals


the actual value branch. [8]

Monitoring of position sensors for cable break

As actual value signal, an SSI encoder or incremental encoder


[2] (digital measuring system) or one or several analogue sensors may be used.
The controller is structured as PIDT1-controller, in which every
component can be activated or deactivated individually. It is
therefore also possible to realise a P- or PT1-controller. The Icomponent can additionally be controlled via a window (upper
and lower limit).
Control parameters can be set block by block or independently
of blocks. In mode 3 , state feedback can be used for attenuating the controller output.
Controller structure:
Sollwertaufschaltung

P
-

Istwert

System deviation monitoring when the HACD is configured


as controller
Monitoring of the supply voltage, all internal voltages and the
10V reference voltage
Monitoring of the microcontroller itself (watchdog) and the
memory (checksum)
Fault monitoring and its reactions can also be configured.
Front panel operation
In conjunction with the 4 keys, the front display can be used to
display and change parameters and for diagnosis purposes.
A corresponding menu structure allows access to the parameters of the VT-HACD. The parameter values can be viewed and
changed.
The following parameters can be accessed:
Command value and ramp parameters

DT1
Sollwert

Monitoring of analogue inputs for overrange and underrange

Actual values

+
T1

Stellgre
-

Closed-loop control parameters


Output adjustment
Analogue I/O
Position sensors

DT1 (Istwert)
Zustandsrckfhrung
Signal
D

Verstrkung

Changes in the configuration, i.e. changes in the signal linkage,


trigger conditions, fault monitoring, etc. are not possible via
front panel operation.
The diagnosis options provided are the displaying of command
and actual values and the output of error messages.
PC program BODAC

Adjustment to the hydraulic system


For the optimum adjustment to the specific characteristics of
hydraulic drives, the following functions are provided upstream
of the analogue output:
Direction-dependent gain [10]
The gain can be adjusted separately for positive and negative
values. An adjustment to the area ratio of single-rod cylinder is
therefore possible.
Characteristic curve correction [11]
This function can be used for compensating for progressive
flow characteristics of proportional directional valves or for implementing an inflected characteristic curve.
Overlap jump / residual velocity [12]
When valves with positive overlap are used, fine positioning
can be employed to increase the static accuracy with the help
of a PDT1-controller. This function can be selected according
to the residual voltage principle or as overlap jump.
Zero point correction [13]
Is used for correcting the zero point of the servo, proportional
or high-response valve connected.

The PC program BODAC can be used for the configuration,


parameterisation and diagnosis of the VT-HACD via a serial interface (RS 232).

INC

SSI
10

10

13 Offset
14 Limitation

overlap jump

13

13

Measuring
sockets

12

12

GND

X2X1

14

14

16

15

b26

d32

b28

d30

outputs

16 OKoutputs and digital

b30
b32

d22

d20
d26
z22
z24
z26
z28
f2

U/I

15

15

OUT2

OUT1

15 Analogue outputs
current or voltage

Fault recognition

CMD1 = LFB1
CMD2 = LFB2
LFB1 threshold
LFB2 threshold
LFB1 threshold
LFB2 threshold
Error 1

11

11

12 Residual velocity and

Control
digital
outputs

LO2

11 Characteristic curve adjustment

Alternating control

Math. linkage or controller

Alternating

LO1

10 Direction-dependent gain

Controller

8
+
LC2
*
/
MIN
MAX
Limit
LFB2 Jump

Controller

8
+
*
/
MIN
MAX
Limit
LFB1 Jump

LC1

10V
+ 10V

OK

DO 1
DO 2
DO 3
DO 4
DO 5
DO 6
DO 7

AO 3

AO 2

AGND

AO 1

Hydraulics Bosch Rexroth AG

4 Adjustment of analogue inputs

6 Math. linkage of inputs

call-ups

binary

Control

Controller parameters (if controller selected in (8))


P
T1
I, I-thresholds
D (LFB1)
D
Comm. value feedforward

Int. comm. value Velocity +


positive
Velocity
negative

Controller parameters (if controller selected in (8))


P
T1
I, I-thresholds
DT1 (LFB1)
DT1
Comm. value feedforward

7 32 blocks for comm. value generation,


change-over of controller parameters

FB2

C2

FB1

Int. comm. value Velocity


positive
Velocity
negative
S-component

3 Enable input and digital inputs

DC

FB2-1 +, -, *, /
MIN, MAX
FB2-2 Limit, Jump
Ratio

C2-1

FB1-1

5 Switching matrix

DC

Binary 1
Binary 2
Binary 3
Binary 4
Binary 5
Binary enable

2b

2a

IN6

IN5

IN4

IN3

IN2

IN1

1 Analogue inputs, voltage or current

z32

z30

z20

z10

INC

SSI

U/I

U/I

U/I

U/I

U/I

U/I

2 SSI encoder (digital encoder)

0V

+ UB

System ground

Shield

d18

d2
d4
d6
d8
d10
d12

f18

f14
f16

f8
f10
f12

f10

f8

f4
f6

b24

b22

b20

b18

b16

b14

b4

b2

b8

b6

b12

VT-HACD-1

Enable

DI 1
DI 2
DI 3
DI 4
DI 5
DI 6

Ua1
/Ua1
Ua2
/Ua2
Ua0
/Ua0

DATA +
DATA

CLK +
CLK

AI 6

AI 5

AI 4

AI 3

AI 2

AI 1

b10

RE 30143/05.05

417
5/12

Block circuit diagram: VT-HACD-1, mode 1 - block call-ups

02

z30

Control logic

Direction-dependent gain

Controller

8
+
LC1 *
/
ConMIN
troller
MAX
Limit
LFB1 Jump

10 Characteristic curve adjustment

ontroller parameters (if controller selected in (8))


T1
P
D (LFB1)
I, I-thresholds
Comm. value feedforward
D

BA

7 32 blocks for comm. value generation,


change-over of controller parameters

4 Adjustment of analogue inputs

Controller parameters (if controller selected in (8))


T1
P
D (LFB1)
I, I-thresholds
value feedforward
Comm.
D

3 Enable input and digital inputs

DC

FB2

C2

6 Math. linkage of inputs

DC

FB2-1 +, -, *, /
MIN, MAX
FB2-2 Limit, Jump
Ratio

C2-1

FB1

2 SSI or incremental

(Home)
(Auto)
(A B)
(B A)

INC

SSI

IN6

IN5

IN4

FB1-1

AB

5 Switching matrix

z32

2b

2a

(Inching+)
(Inching)
(A B E/S)
(B A E/S)

(Setup)

INC

SSI

IN3

IN2

IN1

overlap jump

13 Limitation

12 Offset

12

Measuring
sockets

11

Fault recongition

13

GND

X2X1

15

b26

b28

d30

b30
b32

d22

d20
d26
z22
z24
z26
z28
f2

U/I

14

14

OUT1

10V
+ 10V

OK

DO 1
DO 2
DO 3
DO 4
DO 5
DO 6
DO 7

AO 3

AGND

AO 1

outputs

15 OKoutputs and digital

voltage or current

14 Analogue outputs

at position B
at position A
at phome position
at creep speed (A B)
at creep speed (B A)
Error II error 1
Error II error 2

10

11 Residual velocity and

Control
digital
outputs

LO1

VT-HACD-1

1 Analogue inputs, voltage or current

0V

+ UB

z20

z10

d18

d2
d4
d6
d8
d10
d12

f18

f14
f16

f8
f10
f12

f10

f8

f4
f6

b24

U/I

U/I

U/I

U/I

U/I

U/I

Hydraulics

System ground

Shield

Enable

DI 1
DI 2
DI 3
DI 4
DI 5
DI 6

Ua1
/Ua1
Ua2
/Ua2
Ua0
/Ua0

DATA +
DATA

CLK +
CLK

AI 6

b22

b20

b18

b16

b14

b4

b2

b8

b6

b12

b10

Bosch Rexroth AG

AI 5

AI 4

AI 3

AI 2

AI 1

6/12

418
RE 30143/05.05

Block circuit diagram: VT-HACD-1, mode 2 - motion profile (rapid, creep speed)

SSI

U/I

U/I

U/I

U/I

U/I

+, -, *, /
MIN, MAX C2
Limit, Jump

+, -, *, /
MIN, MAX C3
Limit, Jump

Controller

8
+
*
/
MIN
MAX
Limit
Jump

Math. linkage or controller

10

10

11

11

14 Limitation

overlap jump

12 Residual velocity and

Y2

17
+
*
/
MIN
MAX
Limit
Jump

11 Characteristic curve adjustment

LO2

X2

Y1

X1

17
+
*
/
MIN
MAX
Limit
Jump

13 Offset

Alternating control

LO1

Alternating

Controller

8
+
*
/
MIN
MAX
Limit
Jump

10 Direction-dependent gain

LFB2

LC2

LFB1

LC1

C1
LFB1
C2
LFB2
C3
LFB3

13

13

GND

X2X1

14

14

16

16

b30
b32

d22

d20
d26
z22
z24
z26
z28
f2

b26

d32

b28

d30

10V
+ 10V

OK

DO 1
DO 2
DO 3
DO 4
DO 5
DO 6
DO 7

AO 3

AO 2

AGND

AO 1

17 Math. linkage of outuputs

16 OKoutput and digital outputs

voltage or current

15

U/I

15

15

OUT2

OUT1

15 Analog outputs

Fault
detection

Control
digital
outputs

Measuring
sockets

12

12

Hydraulics Bosch Rexroth AG

4 Adjustment of analogue inputs

Error

Block time

Internal flags

Digital outputs

2
Trigger condition 1 AND
OR Trigger condition

Dwell time

Thresholds

Digital inputs

Controller parameters (if controller selected in (8))


P
T1
I, I-thresholds
D (LFB1)
D
Comm. value feedforward

LFB1 = OFF
FB2
C3
FB3

nt. comm. value + OFF Velocity + positive


C2
C3
FB3 Velocity + negative

Controller parameters (if controller selected in (8))


P
T1
I, I-thresholds
D (LFB1)
D
Comm. value feedforward

LFB1 = OFF
C1
C3
FB3

7 32 blocks for comm. value generation,


change-over of controller parameters

FB3-1 +, -, *, /
MIN, MAX FB3
FB3-2 Limit, Jump
Ratio

C3-2

C3-1

FB2-1 +, -, *, /
MIN, MAX FB2
FB2-2 Limit, Jump
Ratio

C2-2

C2-1

Int. comm. value + OFF Velocity + positive


C1
C3
FB3 Velocity + negative
S-component

3 Enable input and digital inputs

DC

+, -, *, /
MIN, MAX C1
Limit, Jump

FB1-1 +, -, *, /
MIN, MAX FB1
FB1-2 Limit, Jump
Ratio

C1-2

C1-1

6 Math. linkage of inputs

DC

5 Switching matrix

INC

SSI

IN6

IN5

IN4

IN3

IN2

IN1

1 Analogue inputs, voltage or current

z32

z30

z20

z10

d18

d2
d4
d6
d8
d10
d12
d14
d16

f18

2b

2a

2 SSI or incremental

0V

+ UB

Shield
System ground

U/I

f14 INC
f16

f8
f10
f12

f10

f8

f4
f6

b24

b22

b20

b18

b16

b14

b4

b2

b8

b6

b12

b10

VT-HACD-1

Enable

DI 1
DI 2
DI 3
DI 4
DI 5
DI 6
DI 7
DI 8

Ua1
/Ua1
Ua2
/Ua2
Ua0
/Ua0

DATA +
DATA

CLK +
CLK

AI 6

AI 5

AI 4

AI 3

AI 2

AI 1

RE 30143/05.05

419
7/12

Block circuit diagram: VT-HACD-1, mode 3 - structure editor

02

420
8/12

Bosch Rexroth AG

Hydraulics

VT-HACD-1

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC + 40 % 10 %

Operating range:
Upper limit value

uO(t)max 35 V

Lower limit value

uO(t)min 21 V

Current consumption
Fuse

Imax Stand-by current consumption 250 mA


IF 4 AT

Digital inputs

Signal log 0 = 0 to 5 V
log 1 = 15 V to UO

Digital outputs

Signal log 0 = 0 to 5 V
log 1 = 15 V to (UO 3 V)
Imax = 30 mA

Analogue inputs A16


Configuration as voltage input
Range

U 0 to 10 V or 10 V (can be configured)

Input resistance

Ri 100 k, > 10 M for input AI 3

Resolution

5 mV for range 10 V
2,5 mV for range 0...10

Non-linearity

< 10 mV

Configuration as current input


Range
Input resistance

I 0...20 mA or 4...20 mA (can be configured)


Re 100

Power loss

0.15 % (at 500 between pin AI x and 0 V)

Resolution

5 A

Analogue outputs
AO 1 configuration as voltage output
Output voltage

U 0 ... 10V or 10 V (can be configured)

Output current

Imax 20 mA

Load

Rmin 500

Resolution

1.25 mV (14 bits)

Residual ripple content

15 mV (without noise)

AO 1 configuration as current output


Output current
Load

I 0...20 mA or 4...20 mA (can be configured)


Rmax 500

Resolution

1.25 A

Residual ripple content

15 A (without noise)

AO 2 / AO 3
Output voltage

U 10 V

Output current

Imax 10 mA

Load

Rmin 1 k

Resolution

10 mV (11 bits)

Residual ripple content

25 mV (without noise)

Reference voltage

U 10 V
Imax 30 mA

Residual ripple content

< 20 mV

RE 30143/05.05

421
RE 30143/05.05

Hydraulics Bosch Rexroth AG

VT-HACD-1

9/12

Technical data (continued)


Scanning time

t 2 ms

Serial interface

RS 232 (front panel), D-Sub socket

Type of connection

64-pin male connector, DIN 41612, form G

Card dimensions

Euro-card 100 x 160 mm, DIN 41494

Front panel dimensions:


Height

3 HE (128.4 mm)

Width soldering side

1 TE (5.08 mm)

Width component side

7 TE

Permissible operating temperature range

0 to 50 C

Storage temperature range

20 to + 70

Weight

m 0.2 kg

Note:
For details with regard to environment simulation testing in the fields of EMC (electromagnetic compatibility), climate and
stress, see RE 30143-U (declaration on environmental compatibility).

Pin assignment of male connector


Pin

Row z

Row b

Row d

Row f

n.c.

Analogue input AI 3 +

Digital input DI 1

Digital output DO 7

n.c.

Analogue input AI 3

Digital input DI 2

SSI clock +

n.c.

Analogue input AI 2 + 1)

Digital input DI 3

SSI clock

n.c.

Analogue input AI 2 1)

Digital input DI 4

SSI data +; Inc Ua1

10

Shield

Analogue input AI 1 +

3)

Digital input DI 5

SSI data ; Inc /Ua1

12

n.c.

Analogue input AI 1

3)

Digital input DI 6

Inc Ua2

14

n.c.

Analogue input AI 4 + 1)

Digital input DI 7

Inc /Ua2

16

n.c.

Analogue input AI 4 1)

Digital input DI 8

Inc Ua0

18

n.c.

Analogue input AI 5 + 1)

Enable

Inc /Ua0

20

System ground

Analogue input AI 5 1)

Digital output DO 1

n.c.

22

Digital output DO 3

Analogue input AI 6 + 1)

OK

n.c.

24

Digital output DO 4

Analogue input AI 6 1)

n.c.

n.c.

26

Digital output DO 5

Analogue output AO 3, 10V

Digital output DO 2

n.c.

28

Digital output DO 6

Analogue GND 4)

n.c.

n.c.

30

UO: +24 V

10 V

Analogue output AO 1 2)

n.c.

32

L0: 0 V

+10 V

Analogue output AO 2, 10V

n.c.

1)

Inputs AI 2, 4, 5 and 6 can be set to 0...10 V, 10 V,


020 mA or 4...20 mA by means of software.

2)

Output AO 1 can be set to 0...10 V, 10 V, 020 mA or


4...20 mA by means of software.

3)

This input has an input resistance Ri > 10 M

4)

Reference potential for AO 1, AO 2, AO 3, +10 V and 10 V

n.c. ... not assigned in the basic version, but reserved for extensions.

02

422
10/12

Bosch Rexroth AG

Hydraulics

VT-HACD-1

RE 30143/05.05

Pin assignment of D-Sub sockets on the front panel

1
6

Receive data (RS 232)


RxD/TxD-P

Send data (RS 232)

RxD/TxD-P

(B/B)

(A/A)

GND
9
5

DGND

9
5

Profibus

RS 232

Unit dimensions (nominal dimensions in mm)

Rexroth
OK

ENT

UP
DOWN

RS232

X1 X2

122

100
89

3HE (128,4)

ESC

PROFIBUS
I1
I2
I3
I4
I5
I6
I7
I8

8TE (40,3)

O1
O2
O3
O4
O5
O6
O7

165
195,5

423
RE 30143/05.05

VT-HACD-1

Hydraulics Bosch Rexroth AG

11/12

Engineering / maintenance notes / supplementary information


Use low-capacitance cables. Whenever possible, establish cable connections without intermediate terminals.
Sources of electromagnetic interference (e.g. frequency converters) must not be installed in the direct vicinity of the control
electronics.
The installation of power cables in the direct vicinity of the controller card is not permitted.
Do not lay cables of the control electronics in the direct vicinity of power cables.
Install sensor cables separately.
The distance to aerial lines, radio sources and radar equipment must be at least 1 metre.
Provide the installation so that when differential inputs are used, both inputs are always switched on or off simultaneously.
Use relays with gold-plated contacts for passing on command values (small voltages, small currents).
Always shield command value and actual value cables. Connect the shield to shield on the card side and leave the other end
open, otherwise there is a risk of earth loops.
Use highly flexible CU conductors (min 2.5 mm2) for connecting the system ground!
The system ground is an important, integral part of EMC protection of the controller card. It discharges interference that is transported to the controller card through data and supply voltage cables. This function is only ensured, when the system ground
itself cannot inject interference into the controller card. Rexroth recommends that solenoid cables, too, be shielded.
Electrical signals (e.g. signal OK) brought out via control electronics must not be used for switching safety-relevant machine
functions!
(see also European standard Safety requirements for fluid power systems and components - hydraulics EN982:1996)

02

424
12/12

Bosch Rexroth AG

Hydraulics

VT-HACD-1

RE 30143/05.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

425
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Pneumatics

Service
Automation

Mobile
Hydraulics

p/Q controller

RE 30136/05.04

Type VT-VACAF

Series 1X

Overview of contents
Contents

Features

Features

Page
1

Analog amplifiers in Europe card format for installation


in 19 rack

Ordering data and scope of delivery

Differential pressure (draft) controller with PID action

Preferred types

Short-circuit-proof outputs

Front panel

External deactivation for pressure controller

Applications

Monitor signal for controller

Examples

Separate acceleration and braking ramps

Block diagram with terminal assignment

Separate adjustment and deactivation of ramps

Technical data

Adjustable surface area adaptation for cylinders

Unit dimensions

Suitable for pressure sensors (0...10 V, 4...20 mA)


Supply for pressure sensors
Detection of open circuit to pressure sensors
Testing and service equipment
Test adapter type VT-PA-3, see RE 30070
Accessories
Pressure sensors type HM18, see RE 30271

1/8

426
2/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VACAF

RE 30136/05.04

Ordering data and scope of delivery

VT- V A C A
Hydraulic component
(actuation)
Axis control
Valve type
Controller
Actuation
Analog
Function
Differential p/Q control

500

- 10 / V0 /

=A
V0 =
=C

Series
Series 10 to 19

1X =
=A
500 =

Customized version
Catalog version

Serial number for types


Standard version without valve amplifier function

=F

Preferred types (available at short notice)


Type

Material No.

For valve types

VT-VACAF-500-10/V0

0 811 405 147

Valves with on-board electronics

427
RE 30136/05.04

Type VT-VACAF

Industrial Hydraulics

Bosch Rexroth AG

3/8

Front panel

nur bei
0 811 405 158

02

Applications
In contrast to p/Q control, p/Q control of the load can be achieved with the differential pressure controller card, by measuring
the pressure in the A and B-lines of a hydraulic load.
As a result, this control structure is employed in applications in
which the pressure has to be controlled in the direction of motion
of the load not only against a constant pressure, but against a
changing pressure, i.e. wherever closed-loop draft control is
required. Adaptation of the feedback value permits pressure
sensors with an output signal of 0...10 V and 4...20 mA to be
connected.

The setpoint ramps enable setpoint step-changes of psetpoint


to be executed as a ramp function. The error monitoring logics
detect open circuits in the sensor signal lines and faults in the
power supply. The pressure control loop can also be deactivated
externally (flow control).
To actuate the load, this PCB must be coupled to a valve
amplifier card or a valve with on-board electronics.

428
4/8

Bosch Rexroth AG

Industrial Hydraulics

Examples
Application 1
Welding machine

Weld seam

Application 2
Vehicle torsion dynamometer

Type VT-VACAF

RE 30136/05.04

429
RE 30136/05.04

Type VT-VACAF

Industrial Hydraulics

Bosch Rexroth AG

5/8

Block diagram with terminal assignment

02

430
6/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VACAF

RE 30136/05.04

Technical data (For applications outside these parameters, please consult us!)
PCB format

(100 x 160 x approx. 35) mm (W x L x H),


Europe format with front panel (7 modular spacings)

Plug-in connection

Connector DIN 41612-F32

Ambient temperature

Operating temperature 0 C ... +70 C; storage temperature 20 C ... +70 C

Power supply
UB at z2b2

24 V DC nominal
Battery voltage 21...40 V
Rectified AC voltage Ueff = 21...28 V
(single phase, full-wave rectification)

Smoothing capacitor,
connected separately to b4, z4

4700 F/63 V DC, only required if ripple UB > 10 %

Current rating

250 mA max.

Setpoint Q

b20: 0 ... 10 V
z20: 0 V
(Ri = 100 k)

Differential amplifier

Setpoint pdiff

z10: 0 ... 10 V
z12: 0 V

Differential amplifier
Differential amplifier

Feedback signal from pressure sensor

b26: 0 ... +10 V


b28: 0 V
b24:
b30:

b16: 0 ... +10 V


b18: 0 V
z14:
z30:

4 ... 20 mA

Differential amplifier
4 ... 20 mA

Pressure sensor power supply

z6: +15 V, max. 100 mA


z8: 15 V, max. 100 mA

Pressure controller OFF

b10: 6 ... 40 V DC

External controller readout

z24: 24 V/0.1 A max., if controller not operative

Signal source

Supply 10 V from b32, z32 (10 mA) or external signal source

Monitor signal Factual

z16: 10 V

Pressure sensor fault


(open circuit in signal lines)

b22: No fault: +UK; max. 100 mA


b22: Fault: 0 V
b22: LED Ramp OFF A and
Ramp OFF B flash

Ramp times

min. 350 ms (1)


max. 5.6 s (16)

Ramp OFF

z22: 8 ... 40 V DC

z26: 8 ... 40 V DC

16350stages
ms/stage
16 stages

Cylinder surface area adaptation

min. 1:1 (1)


max. 1:4 (16)

LED displays

red: UB fault
red: ramp OFF A
red: ramp OFF B
green/yellow: green, controller operative
yellow, controller not operative
off, controller OFF

Caution: Connect power zero b2 and control zero b12, b14 or z28 separately to central ground (neutral point).

431
RE 30136/05.04

Type VT-VACAF

Industrial Hydraulics

Bosch Rexroth AG

7/8

Unit dimensions (in mm)

Connector DIN 41612-F32

02

432
8/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VACAF

RE 30136/05.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

2004 by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, duplicated or circulated using electronic systems, in any form or by
any means, without the prior written authorization of Bosch Rexroth AG,
Industrial Hydraulics. In the event of contravention of the above provisions, the
contravening party is obliged to pay compensation.
The data specified above only serves to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The details stated do not release you from the
responsibility for carrying out your own assessment and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

433
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Pneumatics

Service
Automation

Mobile
Hydraulics

RE 30134/05.04

p/Q controller

Type VT-VACAP

Series 2X

Overview of contents
Contents

Features

Features

Page
1

Analog amplifiers in Europe card format for installation


in 19 rack

Ordering data and scope of delivery

Suitable for servo solenoid valves with on-board electronics

Preferred types

Closed-loop position control with PID action

Front plate

Short-circuit-proof outputs

Applications

External deactivation for pressure controller

Examples

Suitable for pressure sensors (1...6 V, 0...10 V, 4...20 mA)

Block diagram with terminal assignment

Supply for pressure sensors

Technical data

Detection of open circuit to pressure sensors

Unit dimensions

7
Testing and service equipment
Test adapter type VT-PA-3, see RE 30070
Accessories
Pressure sensors type HM18, see RE 30271

1/8

434
2/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VACAP

RE 30134/05.04

Ordering data and scope of delivery

VT- V A C A P
Hydraulic component
(actuation)
Axis control

500

- 20 / V0 /
2CH =

=A

Valve type
Controller
Actuation
Analog
Function
p/Q control

V0 =
=C

500 =

Customized version
Catalog version
Series
Series 20 to 29

2X =
=A

Option
2 channels

Serial number for types


Standard version without valve amplifier function

=P

Preferred types (available at short notice)


Type

Material No.

For valve types

VT-VACAP-500-20/V0

0 811 405 157

Servo solenoid valves with on-board electronics

VT-VACAP-500-20/V0/2CH

0 811 405 158

Servo solenoid valves with on-board electronics

435
RE 30134/05.04

Type VT-VACAP

Industrial Hydraulics

Bosch Rexroth AG

3/8

Front plate

only in
0 811 405 158

02

Applications
The single-channel p/Q controller card consists of the basic
card in standard Europe format together with DC/DC converter
and front plate. The 2-channel p/Q controller card version
consists of this same basic card equipped with an additional p/Q
daughter card incorporating the same circuitry. The two cards
share a common front plate.
The supply voltage is 24 V DC. This card does not provide the
power supply for the valve being regulated.
The input parameters for the cards comprise the setpoint value
for valve position, the setpoint value for pressure, the actual
(feedback) pressure and any control mode signals. The pressure
sensors with voltage interface receive their voltage supply from
the card (z6/z8).
Cards are for the connection of pressure sensors with both
voltage and current signals.

The setpoint value for pressure is selected via potentiometer.


The potentiometers can be supplied from the card (z32/b12).
Test connections in the front plate and on the card are available
for monitoring and compensation tuning of the most important
parameters.
The circuitry of the 2-channel card is designed to allow fully
independent operation of the controller on the basic card
and that on the daughter card. In this mode, the card can be
employed to control 2 valves with on-board electronics
(see example 2).
An additional channel mode circuit provides a substantial
increase in the range of optional applications for these cards
(see example 1).

436
4/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VACAP

RE 30134/05.04

Examples
Example 1
Common output channel mode

P ist

P soll

Tochterkarte
Daughter card
Carte fille
Q soll

P
I

DIL 5

P ist

P
I

DIL 0
P soll

Basiskarte
Basic card
Carte de base

Example 2
Separate outputs channel mode

Q soll

DIL 5

Kanalmode z30
Channel mode z30
Mode de canal z30

437
RE 30134/05.04

Type VT-VACAP

Industrial Hydraulics

Bosch Rexroth AG

5/8

Block diagram with terminal assignment

ext. p-Regler Abschaltung


Ext. p-controller disconnection
Coupure de p-rgulateur

6...40V

b 10

"Regler off"
DIL 4

P soll

0...10V

z 12

0 V

z 10

PID

Tp4 Tp5

S5/S6
Q soll

0...10V

z 20

0 V

b 20

Istwert Druck Monitorsignal


0...10V
Feedback signal p monitor signal
Signal effectif p signal du monitor
(max. 1mA)
4...20 mA
p-Sensor
p-Sensor
p-Capteur

0V
b 6
b 8

Tp

(E)

z 18
DIL 2

"

z 14

on"

5%
zero

DIL 5
U U

gain
1...6V/0...10V

b 16

0V

b 18

b 32

24V
"
DIL 1

ext. Regler Abfrage


Ext. controller interrogation
24V/20mA
Ext. interrogation du rgulateur

Signalltg.

Np

A
M
V

z 24

UB
+U K

24V

off

z 2

0V

Basiskarte
Basic card
Carte de base

+15 V
0V
-15 V

DC
DC

b 2
z 6

ext. Kanalwechsel
Ext. channel change
Ext. changement de canal

Tochterkarte
Daughter card
Carte fille

+10 V

z 4

Versorgung p-Sensor
Supply p-sensor
Alimentation p-capteur

Meldung
Signal
Annonce
(kein/not/non
8 V 20 mA)

on"

DIL 3

"Regler off"

+15 V /100mA
DIL 0

Potentiometer Versorgung
Supply of potentiometers
Alimentation de potentiom.

6...40V

z 30

+10V

z 32

02

1
No

ext. p-Regler Abschaltung


Ext. p-controller disconnection
Coupure de p-rgulateur

6...40V

z 28

"Regler off"
DIL 4

P soll

0...10V

b 12

0 V

b 14

0...10V

z 22

0 V

b 22

PID

Tp4 Tp5

S5/S6
Q soll

Istwert Druck Monitorsignal


0...10V
Feedback signal p monitor signal
Signal effectif p signal du monitor
(max. 1mA)
4...20 mA
p-Sensor
p-Sensor
p-Capteur

(D)
UA

0V
b 4
b 8

Tp
z 16
DIL 2

"

z 14

on"

5%
zero

(D)
UA
(E)

DIL 5
U U

gain
1...6V/0...10V

b 26

0V

b 28

b 30

24V
"
DIL 1

ext. Regler Abfrage


Ext. controller interrogation
24V/20mA
Ext. interrogation du rgulateur

Np
z 26

Signalltg.

on"

DIL 3
A
M
V

off
"Regler off"

Daughter card installed only on 2-channel version

Meldung
Signal
Annonce
(kein/not/non
8 V 20 mA)

438
6/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VACAP

RE 30134/05.04

Technical data (For applications outside these parameters, please consult us!)

PCB format

(100 x 160 x approx. 35) mm (W x L x H),


Europe format with front plate (7 modular spacings)

Plug connection

Connector DIN 41612-F32

Ambient temperature

Operating temperature 0 C ... +70 C; storage temperture 20 C ... +70 C

Power supply
UB at z2b2

24 V DC nominal
Battery voltage 21...40 V
Rectified AC voltage Ueff = 21...28 V
(single phase, full-wave rectification)

Smoothing capacitor at z4b2

4700 F/63 V DC, only if ripple UB > 10 %

Current rating

0 811 405 157 max. 160 mA


0 811 405 158 max. 220 mA
Basis card

Daughter card

Pressure sensor (1 ... 6 V/0 ... 10 V)


Pressure sensor (4 ... 20 mA)

b26 ref. b28


b24 ref. b28

b16 ref. b18


z14 ref. b18

Pressure sensor supply V

z6 (+15 V)/b8 (0 V)

Pressure setpoint (0 ... 10) V

b12/b14 (0 V)

z12/z10 (0 V)

External controller deactivation

z28: 6 ... 40 V DC

b10: 6 ... 40 V DC

External controller readout

z26: 24 V DC, max. 20 mA

z24: 24 V DC, max. 20 mA

Monitor signal pactual

z16: 0 ... 10 V DC

z18: 0 ... 10 V DC

External channel selection mode

z30: 6 ... 40 V DC

Flow setpoint

z22: 0 ... 10 V DC
b22: 0 V

Potentiometer supply

z32: +10 V, max. 10 mA

Output

UAI; b4/b8 (0 V): 0 ... 10 V


Load RL > 1 k

Cable: Pressure sensor


Cable: Valve
Cable: PLC signals

4 x 0.5 mm2 (screened)


5 x 0.5 mm2 (screened)
0.5 mm2 (screened)

LED displays/channel

Pressure controller OFF


Controller operating
Open circuit to pressure sensor (both above-mentioned LEDs flash)

Special features

Monitoring for open circuit to pressure sensor


Test connections for major parameters
External deactivation of pressure controller
External channel selection mode
For use with various pressure sensors

z20: 0 ... 10 V DC
b22: 0 V
UAIl; b6/b8 (0 V): 0 ... 10 V
Load RL > 1 k

439
RE 30134/05.04

Type VT-VACAP

Industrial Hydraulics

Bosch Rexroth AG

7/8

Unit dimensions (in mm)

Connector DIN 41612-F32

02

440
8/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VACAP

RE 30134/05.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

2004 by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, duplicated or circulated using electronic systems, in any form
or by any means, without the prior written authorization of Bosch Rexroth AG,
Industrial Hydraulics. In the event of contravention of the above provisions,
the contravening party is obliged to pay compensation.
The data specified above only serves to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The details stated do not release you from the
responsibility for carrying out your own assessment and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

441
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Pneumatics

Service
Automation

Mobile
Hydraulics

RE 30058/03.04

p/Q amplifier

1/8

Type VT-VARAP1

Series 2X

List of contents
Contents

Features
Page

Suitable for actuating directly operated and pilot operated


servo solenoid valves

Features

Ordering data and scope of delivery

Analog amplifiers in Eurocard format for installation in 19 rack

Preferred types

Output stage with closed-loop control

Front panel

Rapid energizing and de-energizing for fast response times

Block diagram with terminal assignment

3 and 4

Enabling input

Technical data

Short-circuit-proof outputs

Additional information / example

External control shutoff

Example / unit dimensions

Open-circuit detection for feedback signal cable and pressure


sensor
Suitable for pressure sensors (1...6 V, 0...10 V, 4...20 mA)
Closed-loop position control with PID action
Testing and service equipment
Test box type VT-PE-TB2, see RE 30064
Test adapter type VT-PA-3, see RE 30070
Pressure measuring technology
Pressure sensor HM18, see RE 30271

442
2/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VARAP1

RE 30058/03.04

Ordering data and scope of delivery

VT- V A R A P

Hydraulic component
(actuation)
Axis control
=A
Valve type
Servo solenoid valve

Option
No code
Servo solenoid valve NG 6/10
directly operated
5/3V =
p/Q valve NG 10
directly operated
2STV =
servo solenoid valve,
pilot operated, NG 10, 16, 25
3/2V =
servo solenoid valve,
pilot operated,
control line A X

=R

Actuation
Analog
Function
p/Q control
Output stages
1 output stage

=A
=P
=1
V0 =

Series
Series 20 to 29

2X =

Serial numbers for types


2.7 A solenoid
3.7 A solenoid

527 =
537 =

Preferred types (available a short notice)


Type

Material no.

For valve types

VT-VARAP1-527-20/V0

0 811 405 152

4WRPH 6

VT-VARAP1-537-20/V0

0 811 405 153

4WRPH 10

VT-VARAP1-537-20/V0/5/3V

0 811 405 154

5WRP

VT-VARAP1-527-20/V0/2STV

0 811 405 155

4WRL

VT-VARAP1-527-20/V0/3/2VAX

0 811 405 156

3/2 V; NG 25, 32, 50

Front panel

Customer version
Catalog version

10

0V

24V

6...40V

p-Regler AUS
p-controller OFF
Rgulateur p arr.

Sensor Versorgung
+15V
Sensor supply
b 30
Alimentation capteur -15V

z6

2-1

z 12
Sollwert p
0...+10V
Setpoint signal p
z 10
Signal consigne p
0V

1-3

1-2

2-3

1-5

b 16
+

+U K

100 k

100 k

24V=/
max 100 mA

100 k
ON

0-Punkt

P ist

Q max

Diff. Amp.

grn
+U K green
vert

max 40 V

8.5 V=

10 V / 10mA

+10 V / 10mA

3-1 3-5

5%

Leitungsbruch
Cable break
Rupture cble

Justierung Nullpunkt
Adjustment zero
Tarage zero

Sicherheitslogik
safety logic
logique de
surveillance

15 V

+15 V

10 V

+10 V

1-1

3-4

3-3

3-2

L - 0V

St. - 0V

-15V

+15V

Lvdt.

rot
red
rouge
gelb
yellow
jaune

15 V
10 V

+U K

+U K

Ref-0-

10 V

b 8

b 6

b 30

b 24

z 30

b 22

z 28

b 2

b 4

z 4

z 2

b 2 Leistungs-Null
Power zero
Zro de puissance
z 28 Steuer-Null
Control zero
Zro de controle

Sternpunkt 0 V
ground
masse

+U B 24 V=/max. 1.5A Versorgung


Supply
Alimentation
4 700 F / 63V=
10 % ripple (U B )

Industrial Hydraulics

1...6V/0...10V

2-4

1-6

b 18

4...20mA z 14

p-sensor
p-sensor
p-capteur

Rev. 0V

1-7

1-4

z 24

b 10

2-2

b 20

z 20

z 22

z 16

b 14

b 12

b 32

z 32

Type VT-VARAP1

p-Regler arbeitet
p-controller works
Rgulateur p en action

0...+10V

Test (p)

z 18

max 40 V=

+10V

0...10V
Sollwert Q
Setpoint signal Q U E
Signal consigne Q
0V

Fehler
Fault
Erreur

Freigabe
Enabling
Deblocage

Steuer-Null
Control zero
Zero de controle

Pot. Versorgung
Supply of pot.
Alimentation de pot.

RE 30058/03.04

443
Bosch Rexroth AG
3/8

Block diagram with terminal assignment

0 811 405 152, 0 811 405 153, 0 811 405 154

02

0V

24V

6...40V

p-Regler AUS
p-controller OFF
Rgulateur p arr.

Sensor Versorgung
+15V
Sensor supply
b 30
Alimentation capteur -15V

1-3

1-2

+U K

100 k

100 k

24V=/
max 100 mA

100 k
ON

0-Punkt

P ist

Q max

Diff. Amp.

grn
+U K green
vert

max 40 V

8.5 V=

3-1 3-5

5%

Leitungsbruch
Cable break
Rupture cble

Justierung Nullpunkt
Adjustment zero
Tarage zero

Sicherheitslogik
safety logic
logique de
surveillance

15 V

+15 V

10 V

+10 V

1-1

3-4

3-3

3-2

L - 0V

St. - 0V

-15V

+15V

Lvdt.

rot
red
rouge
gelb
yellow
jaune

15 V
10 V

+U K

+U K

Ref-0-

10 V

Ref-0-

10 V

b 8

b 6

b 30

b 24

z 30

b 22

b 30

b 28

z 30

b 26

z 28

b 2

b 4

z 4

z 2

b 2 Leistungs-Null
Power zero
Zro de puissance
z 28 Steuer-Null
Control zero
Zro de controle

Sternpunkt 0 V
ground
masse

+U B 24 V=/max. 1.5A Versorgung


Supply
Alimentation
4 700 F / 63V=
10 % ripple (U B )

Type VT-VARAP1

z6

2-1

z 12
Sollwert p
0...+10V
Setpoint signal p
z 10
Signal consigne p
0V

2-3

1-5

b 16

1...6V/0...10V

2-4

1-6

b 18

4...20mA z 14

p-sensor
p-sensor
p-capteur

1-7

1-4

2-2

z 24

b 10

z 18

b 20

z 20

z 22

z 16

10 V / 10mA

+10 V / 10mA

Industrial Hydraulics

Rev. 0V

p-Regler arbeitet
p-controller works
Rgulateur p en action

0...+10V

Test (p)

0...10V
Sollwert Q
Setpoint signal Q U E
Signal consigne Q
0V

Fehler
Fault
Erreur

max 40 V=

+10V

b 14

b 12

b 32

z 32

Bosch Rexroth AG

Freigabe
Enabling
Deblocage

Steuer-Null
Control zero
Zero de controle

Pot. Versorgung
Supply of pot.
Alimentation de pot.

4/8

444
RE 30058/03.04

Block diagram with terminal assignment

0 811 405 155, 0 811 405 156

445
RE 30058/03.04

Type VT-VARAP1

Industrial Hydraulics

Bosch Rexroth AG

5/8

Technical data (For applications outside these parameters, please consult us!)

P.C.B. format

(100 x 160 x approx. 35) mm (B x L x H)


Europe format with front panel (7 modular spacings)

Plug connector

Connector DIN 41612 F 32

Ambient temperature

0 C +70 C, storage temperature min. 20 C; max. +70 C

Weight m

0.25 kg

Power supply
UB to z 2 b 2

24 V DC
Battery voltage 2140 V
Rectified AC voltage Ueff = 2128 V
(single-phase, full-wave rectification)

Smoothing capacitor, separately to b 4, z 4

4700 F/63 V DC, only required if UB ripple >10 %

Valve solenoid A/VA max.

2.7/40 (NG 6)

3.7/60 (NG 10)

Current rating

1.7 A

2.7 A

The current rating can rise at min. UB


and long cable length to control solenoid
Power consumption (typical)

37 W

55 W

Input signal (setpoint Q)

b 20: 0...10 V
z 20: 0...10 V
(Ri = 100 k)

Difference amplifier

Input signal (setpoint p)

z 12: 0...10 V
z 10: 0 V

Difference amplifier

Feedback signal from pressure sensor

z 14: 4...20 mA current input


b 16: 0...+10 V / 1...+6 V voltage input
b 18: 0 V reference

Pressure control OFF

b 10: 6...40 V DC

External scanning of controller

z 24: 24 V/0.1 A max.

Limit frequency

For applications 30 Hz

Signal source

Potentiometer 10 k, 10 V supply from b 32, z 32 (10 mA)


or external signal source

Output stage enable

To z 16, U = 8.5...40 V, Ri = 100 k, LED (green) on front panel lights up

Sensor power supply

z 6: +15 V/35 mA, Ri 25

Position transducer

02

Power supply

b 30: 15 V/25 mA
z 30: +15 V/35 mA

Pilot stage signal

b 22: 0 10 V, RL > 10 k/ref. b 24

Main stage signal


Solenoid output

b 26: 0 10 V, RL > 10 k/ref. b 28


Clocked current regulator

b6b8

Imax. = 2.7 A

Imax. = 3.7 A

Length of amplifier to valve cables

Solenoid cable:

20 up to 20 m 1.5 mm2
20 up to 60 m 2.5 mm2
4 x 0.5 mm2 (screened)
4 x 0.5 mm2 ( screened)

Position transducer:
Pressure sensor:
LED displays

Green: Enable
UB ON
Yellow: Position transducer open circuit
Red: Supply voltage too low
Yellow: Pressure control OFF
Yellow: Pressure control working
Both yellow LEDs flashing: Pressure sensor open circuit

Special features

Open-circuit protection for feedback signal cable and pressure sensor


Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
External control shutoff

Error signal
Position transducer open circuit
UB too low
15 V stabilization

z 22: No fault: +UK; max. 100 mA


Fault: 0 V

Note
Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point).

446
6/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VARAP1

RE 30058/03.04

Additional information / Example


Applications
The p/Q amplifiers comprise a base card with front panel,
containing the valve amplifier with position control and
a daughter card. The daughter card, inserted in the base card,
is where the actual pressure control process occurs.
This amplifier is only available as a single combination unit.
When used together with the appropriate servo solenoid valves
(see table on page 2) and pressure sensors (sensor signal
1...6 V, 0...10 V or 4...20 mA), this unit can be employed for
controlling flow and pressure in a closed-loop control circuit.
The input parameters are the setpoints for pressure p and flow Q.
Pressure and valve spool position are transmitted as feedback
values.

Example 1
Pressure control in a cylinder chamber in order to obtain
a constant clamping force.

The combination of valve amplifier and p/Q amplifier functions:


a) As a flow controller when psetpoint < pfeedback value, that is,
while the pressure control function remains inoperative.
b) As a pressure regulator when psetpoint > pfeedback value, that is,
the flow is reduced until pfeedback value = psetpoint. The pressure
control only functions when there is a positive setpoint
voltage to z 20.
The setpoint Q corresponds to the spool position as long as
the pressure control system remains inoperative, that is when
psetpoint > pfeedback value or when the pressure control is switched off
(DIL 4 OFF). Setpoint Q can lie within the range UE = 0...10 V.
For effective pressure regulation, however, setpoint p must be
supplemented by a setpoint Q. This is UE 2...+10 V.

447
RE 30058/03.04

Type VT-VARAP1

Industrial Hydraulics

Bosch Rexroth AG

7/8

Example
Example 2
The flow is controlled with load compensation by means of
a pressure compensator, and the pressure is controlled in the
closed loop (pressure override).

02

Unit dimensions (in mm)

Connector DIN 41612-F32

448
8/8

Bosch Rexroth AG

Industrial Hydraulics

Type VT-VARAP1

RE 30058/03.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

2004 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, duplicated or circulated using electronic systems, in any form
or by any means, without the prior written authorization of Bosch Rexroth AG,
Industrial Hydraulics. In the event of contravention of the above provisions,
the contravening party is obliged to pay compensation.
The data specified above only serves to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The details stated do not release you from the
responsibility for carrying out your own assessment and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

449
RE 00112-04

Hydraulics Bosch Rexroth AG

Sensors and signal transmitters

Designation

Type

Initiator

VT-IA4010

Series

Data
sheet no.

Page

1X

29726

451

Electronic pressure switch with integrated analogue output

HEDE 10.../1/

2X

30276

455

Electronic pressure switch with two switching outputs

HEDE 10.../2/

2X

30278

463

Pressure transducer with integrated electronics

HM17

1X

30269

471

Setpoint generator

VT-SWMA4-5

30285

477

Potentiometer

VT-SWMA5-5

30287

481

Electronic signal transmitter (three-axis version)

VT10399

5X

29755

485

Electronic signal transmitter (two-axis version)

VT10406

3X

29754

491

Electronic signal transmitter (single-axis version)

VT10468

3X

29753

499

Electronic remote control for the actuation hydraulic axis

4THES5, THEC5, THE5

29881

505

01

03

03

05

06

450
Bosch Rexroth AG

Hydraulics

RE 00112-04

451

RE 29726/06.05
Replaces: 08.03

Initiator

1/4

Type VT-IA4010

Series 1X

fo_29726_d

Overview of contents
Contents

Features
page

suitable for amplifier VT 3015-1X

Features

proximity sensor with analog output signal

Ordering details

Function/installation dimensions

value of output voltage is proportional to the clearance between its active face and a cam surface

Technical data

service life is not limited by mechanical operations

Terminal connections

active face on the end of the device

Output curve

cylindrical form
housing an fixing clamp made from plastics
fully encapsulated connection cable
connection cable: 4 x 0,75 mm2, shielded, length 2 m

452
2/4

Bosch Rexroth AG

Hydraulics

VT-IA4010

RE 29726/06.05

Ordering details

VT-IA4010 1X
Series 10 to 19
(10 to 19: externally interchangeable)

= 1X

Further details in clear text

Function/installation dimensions (nominal dimensions in mm)

Side A

Side B
min. 2.5

Cam

Cam

20

77,4

5,5
Initiator

Initiator

32

L0

+U

6V

6V

amplifier

Note: the cam gradient and adjustment determines the deceleration distance.

+U

L0
amplifier

453
RE 29726/06.05

Hydraulics Bosch Rexroth AG

VT-IA4010

3/4

Technical data (for applications outside these parameters, please consult us!)

Supply voltage

U 10 to 15 V
U 0 to 6 V

Output voltage
Power requirements

I approx. 6 mA

Working range

s 3 to 10 mm

Permissible ambient temperature range

20 to +80 C

Weight

m 0.1 kg

Terminal connections

Black

1k

Brown

Yellow/Green
Blue

+U

Output: Umax = 6 V

Earth (ground)
-U

03
L0 amplifier

454
4/4

Bosch Rexroth AG

Hydraulics

RE 29726/06.05

VT-IA4010

Output curve

Output voltage in V

Ambient temperature 25C


9
8,5
8
7,5
7
6,5
6
5,5
5
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
+ 0,5

Working range
1

10

11

12

13

14

15

16

17

18

19

20

Clearance a (see page 2) in mm

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

455

RE 30276/05.05
Replaces: 30275

Electronic pressure switch


with integrated analogue output

1/8

Type HEDE 10/1/

Component series 2X

tb0002

Table of contents
Contents

Features
Page

Features

Ordering code

Technical data

2 and 3

Pin assignment K41

Unit dimensions

Accessories

5 and 6

Suitable for measuring pressures and converting the measured


values into electrical signal variables
EMC properties allow the use of this pressure switch also in
critical applications
Ceramic / capacitive sensor
Connecting cable with 4-pin M12 plug on housing
Accuracy class 1.0
Connection thread G1/4
Parts in contact with media are made of stainless steel, ceramic and FKM
Compact design
One switching output and one analogue output

Information on available spare parts:


www.boschrexroth.com/spc

456
2/8

Bosch Rexroth AG

Hydraulics

HEDE 10/1/

RE 30276/05.05

Ordering code
HED E

10 A1 2X

K41 G24 1

*
Further details in clear
text

Hydraulic
electrical
pressure switch

V=

Integrated electronics

=E

Component type

= 10

Hydraulic interface 1/4

= A1

Component series

1=
= 2X

Pressure stages
100 bar
250 bar
400 bar
600 bar

FKM seals
Caution!
Observe compatibility of
seals with hydraulic fluid used!
One switching and one analogue output

G 24 =

= 100
= 200
= 400
= 600

Supply voltage
Plug variant
M12, 4-pin as standard

K41 =

Technical data (for applications outside these parameters, please consult us!)
Input variables
UO 18 to 36 VDC

Auxiliary energy
Current consumption

I < 50 mA
pN in bar

100

250

400

600

pmax in bar

400

750

800

900

p in bar

650

1000

1200

1200

Measuring range
Overload safety
Burst pressure
Output variables

U 0 to 10 VDC minimum load 2600

Analogue output

I 4 20 mA (max. load (UO 10) x 50 )


Switching output

Rise time (10 to 90 %)

t 3 ms

Current carrying capacity

I 250 mA

Response time

t < 3 ms (with response time set to dAP = 3)

Max. switching frequency

f 170 Hz (at dAP = 3)

Characteristic curve deviation:


(initial point setting according to DIN16086)

< 0.5 %

Temperature coefficient within nominal temperature range


Highest TC of zero point
Highest TC of span

0.2 % / 10 k
0.2 % / 10 k

Hysteresis

< 0.1 %

Repeatability

0.1 %

Long-term drift under reference conditions (6 months)

0.05 %

Ambient conditions
Limit temperature range

20 to +80 C at UO < 32 V
20 to +60C at UO > 36 V

Storage temperature range

40 to +100 C

Medium temperature range

25 to +80 C

Mechanical data
Pressure port

G1/4

Electrical connection

M12 plug-in connection

457
RE 30276/05.05

3/8

Hydraulics Bosch Rexroth AG

HEDE 10/1/

Technical data (continued)


Hysteresis / window; normally open / normally closed; pickup, drop-out delay; attenuation; display unit / analogue output:
voltage or current

Programming options

Pressure stages

100

250

400

600

Switching point SP

bar

1.0 ... 100

2 ... 250

4 ... 400

6 ... 600

Release position, rP

bar

0.5 ... 99.5

1 ... 249

2 ... 398

3 ... 597

In increments of

bar

0.5

Adjustable response time of a switching output and resulting switching


frequency

Response time (dAP) ms 3 ... 500


Hz 170 ... 1

Adjustable delay time dS, dr

s 0.0; 0.2 ... 50.0

Environmental compatibility
Type of protection / housing to IEC 60529

IP67

Class of protection EN 50178

III

Insulation resistance

M > 100 (500 VDC)

Resistane to shock to IEC 60068-2-27

g 50 g, 11 ms

Resistance to vibration to IEC 60068-2-6

g 20 g, 10 ... 2000 Hz

Switching cycles min.

100 million

Approval

cULus

EMC

EN 61000-4-2 ESD
EN 61000-4-3 HF radiated
EN 61000-4-4 burst
EN 61000-4-5 surge
EN 61000-4-6 HF cable-bound

4 / 8 kV
10 V/m
2 kV
0.5 / 1 kV
10 V

Housing material

EPDM/X (Santoprene); FKM; PBTP (Pocan); PC (Macrolon);


V2A (1.4301)

Materials in contact with the medium

V2A (1.4305); ceramic; FKM

Connection

M12 plug-in connection, gold-plated contacts

03

Pin assignment K41


One switching and

1 BN

one analogue output:

L+

4 BK

HEDE 10

2 WH
3 BU

Detail of plug on the device: 2


3

1
4

BN

Brown

WH White

BU

Blue

BK

Black

458
4/8

Bosch Rexroth AG

Hydraulics

HEDE 10/1/

RE 30276/05.05

Unit dimensions (nominal dimensions in mm)


34

48

1 Status LEDs

1
2

M12 x 1

2 4-digit alphanumerical display

3 Programming key
4 Dimension for pressure
stage 100 bar and 250 bar
5 Dimension for pressure
stage 400 bar and 600 bar

91,5
(94)

3
4
57,3
(59,8)

M12 x 1
5

13,5

1,3

5
30
21,5
27

G1/4

Recommended installation:
Vibration-free installation!

459
RE 30276/05.05

Hydraulics Bosch Rexroth AG

HEDE 10/1/

5/8

Accessories
Cable sockets:
Technical data:
Current carrying capacity:

4A

Temperature range:

25...90 C

Type of protection:

IP 67

Contacts:

CuZn

Contact surface:

Gold-plated

Housing:

TPU

Seal:

FKM

15

Designation

Material no.

04 POL (with 2 m cable)

R900773031

42
10,5

04 POL (with 5 m cable) R900779498

M 12x1

04 POL (with 2 m cable) R900779504


15

CuZn/Ni

Wire cross-section:

4 x 0,34 mm

Sheath material:

PUR

Shield:

Not connected
on plug side

Sheath diameter:

5.0 mm

Sheath colour:

Black

Bending radius for


dyn. application:

min. 50 mm

04 POL (with 5 m cable) R900779503

39

Fitting:

27

M 12x1

10,5
46

20

04 POL (without cable)1)

R900773042

04 POL (without cable)1)

R900779509

Connection:
1 BN
2

2 WH

36

20

4
30

4 BK

18

3 BU

M12x1

03
15

M12x1

1) Type

of protection IP68

Hydraulic fitting:
Material no.

17

AB 20-28

R900012451 / 1

22

19

G 1/4
5

Designation

O-ring

12
Elastic profiled seal

49

460
6/8

Bosch Rexroth AG

Hydraulics

HEDE 10/1/

Accessories (continued)
Mounting clamp for HEDE 10
Material no.

Mounting clamp

R900786138

70

58

Designation

34

29

12
6,5

52
Protective cap for HEDE 10
Material no.

Protective cap M12

R900786141

45

37

35

Designation

16
3

RE 30276/05.05

461
RE 30276/05.05

HEDE 10/1/

Hydraulics Bosch Rexroth AG

7/8

Notes

03

462
8/8

Bosch Rexroth AG

Hydraulics

HEDE 10/1/

RE 30276/05.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

463

RE 30278/04.05
Replaces: 30275

Electronic pressure switch


with two switching outputs

1/8

Type HEDE 10/2/

Component series 2X

H6972

Table of contents
Contents

Features
Page

Suitable for the measurement of pressures

Features

EMC properties allow the use also in critical applications

Ordering code

Sensor ceramic / capacitive

Technical data

2 and 3

Connecting cable with 4-pin M12 plug on the housing

Pin assignment K41

Accuracy class 1.0

Unit dimensions

Connection thread G 1/4

Accessories

5 and 6

Parts that are in contact with the medium are made of stainless steel, ceramics or FKM
Compact design
Two switching outputs

464
2/8

Bosch Rexroth AG

Industrial Hydraulics

HEDE 10/2/

RE 30278/04.05

Ordering code
HED E

10 A1 2X

K41 G24 2

*
Further details in clear
text

Hydraulic
electrical
pressure switch

V=

Integrated electronics

FKM seals
Caution!
Observe compatibility of seals with
the hydraulic fluid used!

=E

Type of component

= 10

Hydraulic interface 1/4

= A1

Component series

2=
= 2X

Pressure stage
100 bar
250 bar
400 bar
600 bar

Two switching outputs

G 24 =

= 100
= 200
= 400
= 600

Supply voltage
Plug-in variant
M12, 4-pin as standard

K41 =

Technical data (for applications outside these parameters, please consult us!)
Input variables
UB 18 to 36 VDC

Auxiliary power
Current consumption

I < 50 mA

Measuring range
Overload safety
Burst pressure

pN in bar

100

250

400

600

pmax in bar

400

750

800

900

p in bar

650

1000

1200

1200

Output variables
Switching output

Current carrying capacity

I 250 mA

Response time

t < 3 ms (with set response time dAP = 3)

Max. switching frequency

f 170 Hz (at dAP = 3)

Characteristic curve deviation:


(initial point setting to DIN16086)

< 0.5 %

Temperature coefficient in the nominal temperature range


Highest TC of the zero point
Highest TC of the range

0.2 % / 10 k
0.2 % / 10 k

Hysteresis

< 0.25 %; 0.5 % for pressure stage 600 bar

Repeatability

< 0.1 %

Long-term drift under reference conditions (6 months)

0.05 %

Ambient conditions
Limit temperature range

20 to +80 C at UB < 32 V
20 to +45 C at UB > 36 V

Storage temperature range

40 to +100 C

Fluid temperature range

25 to +80 C

Mechanical data
Pressure port

G1/4

Electrical connection

M12 plug-in connection

465
RE 30278/04.05

3/8

Industrial Hydraulics Bosch Rexroth AG

HEDE 10/2/

Technical data (continued)


Hysteresis / window; n.o. / n.c; pick-up, drop-out delay;
damping; unit of indication / diagnosis output

Programming options
Pressure stages

100

250

400

600

bar

1.0 ... 100

2 ... 250

4 ... 400

6 ... 600

Resetting point, rP

bar

0.5 ... 99.5

1 ... 249

2 ... 398

3 ... 597

in increments of

bar

0.5

Switching point SP

Adjustable response time of a switching output and resulting switching


frequency

Response time (dAP) ms 3 ... 500


Hz 170 ... 1

Adjustable delay dS, dr

s 0.0; 0.2 ... 50.0

Environmental compatibility
Type of protection / housing to IEC 60529

IP67

Protection class to EN 50178

III

Insulation resistance

M > 100 (500 VDC)

Resistance to shock to IEC 60068-2-27

g 50 g, 11 ms

Resistance to vibration

g 20 g, 10 2000 Hz)

Switching cycles min.

100 million

Approval

cULus

EMC

EN 61000-4-2 ESD
EN 61000-4-3 HF radiated
EN 61000-4-4 burst
EN 61000-4-5 surge
EN 61000-4-6 HF cable-bound

4 / 8 kV
10 V/m
2 kV
0,5 / 1 kV
10 V

Housing material

EPDM/X (Santoprene); FKM; PBTP (Pocan); PC (Macrolon);


V2A (1.4301)

Materials in contact with the medium

V2A (1.4305); ceramics; FKM

Connection

M12 plug-in connection, gold-plated contacts

Pin assignment K41


Two switching outputs:

03

1 BN

L+

2 WH

HEDE 10

4 BK
3 BU

Detail view on the


plug of the device:

2
3

1
4

BN

Brown

WH White

BU

Blue

BK

Black

466
4/8

Bosch Rexroth AG

Industrial Hydraulics

HEDE 10/2/

RE 30278/04.05

Unit dimensions (nominal dimensions in mm)


34

48

1 Status LEDs

1
2

M12 x 1

2 4-digit alphanumerical display

3 Programming key
4 Dimension for pressure
stages 100 bar and 250 bar
5 Dimension for pressure
stages 400 bar and 600 bar

91,5
(94)

3
4
57,3
(59,8)

M12 x 1
5

13,5

1,3

5
30
21,5
27

G1/4

Installation recommendation:
Vibration-free installation!

467
RE 30278/04.05

Industrial Hydraulics Bosch Rexroth AG

HEDE 10/2/

5/8

Accessories
Cable sockets:
Technical data:
4A

Temperature range:

25...90C

Type of protection:

IP 67

Contacts:

CuZn

Contact surface:

Gold-plated

Housing:

TPU

Seal:

FKM

15

42

Material no.

04 POL (with 2 m cable)

R900773031

04 POL (with 5 m cable)

R900779498

04 POL (with 2 m cable)

R900779504

04 POL (with 5 m cable)

R900779503

04 POL (without cable)1)

R900773042

04 POL (without cable)1)

R900779509

10,5

Current carrying capacity:

Designation

CuZn/Ni

Wire cross-section:

4 x 0.34 mm

15

Sheath material:

PUR

Shield:

Not connected
on plug side

Sheath diam.:

5.0 mm

Sheath colour:

Black

Bending radius for


dyn. application:

min. 50 mm

27

39

Fitting:

M 12x1

M 12x1

10,5
46

20
Connection:
1 BN
2

2 WH

36

20

4
30

4 BK

18

3 BU

M12x1

03

15

M12x1

1) Type

of protection IP68

Hydraulic fitting:
Material no.

17

AB 20-28

R900012451 / 1

22

19

G 1/4
5

Designation

O-ring

12
Elastic profiled seal

49

468
6/8

Bosch Rexroth AG

Industrial Hydraulics

HEDE 10/2/

RE 30278/04.05

Accessories (continued)
Fixing clamp for HEDE10
Material no.

Fixing clamp

R900786138

70

58

Designation

34

29

12
6,5

52
Protective cap for HEDE10
Material no.

Protective cap M12

R900786141

45

37

35

Designation

16
3

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

469
RE 30278/04.05

HEDE 10/2/

Industrial Hydraulics Bosch Rexroth AG

Notes

03

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

470
8/8

Bosch Rexroth AG

Industrial Hydraulics

HEDE 10/2/

RE 30278/04.05

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

471

RE 30269/07.05
Replaces: 02.03

Pressure transducer
with integrated electronics

1/6

type HM 17

Series 1X

H6983_d

Table of contents
Contents

Features
Page

Features

Ordering code

Technical data

2, 3

Suitable for measuring pressures in hydraulic systems


Conversion of a pressure into an electrical analogue signal
(e.g. for use in control and instrumentation technology)
Sensor in thin-film technology

Pin assignment

4-pin M12 component plug on housing

Unit dimensions

Accuracy class 0.5

Accessories

Measuring range max. up to 600 bar


Connecting thread G1/4
Parts that come into contact with fluids are made of stainless
steel
Compact build
Operational reliability due to high bursting pressure and
polarity reversal, overvoltage and short-circuit protection
CE mark

472
2/6

Bosch Rexroth AG

Hydraulics

HM 17

RE 30269/07.05

Ordering code

HM 17

1X

V0

Pressure transducer with integrated electronics

0=

Series 10 to 19
(10 to 19: unchanged technical data and pin assignment)

= 1X

Measuring ranges:
Up to 50 bar
Up to 100 bar
Up to 200 bar
Up to 250 bar
Up to 315 bar
Up to 400 bar
Up to 450 bar
Up to 600 bar

No options

V0 =

= 050
= 100
= 200
= 250
= 315
= 400
= 450
= 600

Standard version

C=
H=
H=

Current output 4 - 20 mA
Voltage output 0.1 - 10 V
Voltage output 0.5 - 5 V

The plug-in connector is not included in the


scope of supply! (see page 5)

Technical data (for applications outside these parameters, please consult us!)
Input variables
Auxiliary power

UB 19 to 36 VDC (8 to 36 VDC with output 0.5 to 5 V)

Current consumption
Measuring range
Overload protection
Bursting pressure

I 4 mA (with voltage output)


pN in bar

50

100

200

250

315

400

450

600

pmax in bar

120

200

500

500

780

800

1200

1200

p in bar

550

1200

1200

1500

1700

2400

2400

Dead volume

V ca. 200

800
mm3

Output variables
Output signal and permissible max load RA

I 4 to 20 mA, two-wire RA = (UB - 10 V)/0.02 A with RA in Ohm


and UB in Volt
U 0.5 to 5 V, three-wire RA > 10 k
U 0.1 to 10 V, three-wire RA > 20 k

Balancing error:
Zero point

< 0.15 % 1)

Final value

< 0.3 % 1)

Temperature coefficients in the nominal temperature range


Highest TC of the zero point

< 0.2 %/10 K

Highest TC of the span

< 0.2 %/10 K

Characteristic curve deviation

typ. < 0.2 % 1) (limit point setting)

Hysteresis

< 0.1 % 1)

Repeatability

< 0.05 % 1)

Adjustment time (10 to 90 %)


Long-term drift (1 year) under reference conditions

t < 2 ms
< 0.2 % 1)

473
RE 30269/07.05

Hydraulics Bosch Rexroth AG

HM 17

3/6

Technical data (continued)


Ambient conditions
Nominal temperature range

-20 to +80 C

Limit temperature range

-40 to +85 C

Storage temperature range

-40 to +100 C

Hydraulic fluid temperature range

-40 to +90 C

Mechanical data
Pressure port

G1/4 male thread according to DIN 3852 form E


(pressure channel with nozzle = 0.6 mm);
Profiled seal according to DIN 3869, material FKM

Materials:
Parts that come into contact with measuring substance

CrNi steels 1.4571 and 1.4542

Housing

CrNi steels 1.4571

Tightening torque

MA 10 Nm

Shock load capacity

1000 g as per IEC 60068-2-27

Vibration capacity

20 g as per IEC 60068-2-6

Electrical connection

4-pin M12 component plug on housing 2)

Weight

m 0.05 kg

1)

Referred to full measuring range

2)

Recommendation: Use of shielded connecting cables;

Note!

With plug-in connector M12x1, see page 5

For details regarding environment simulation tests in the


field of EMC (electro-magnetic compatibility), climate and mechanical stress, see RE 30266-U (declaration of environmental
compatibility). The information provided in this declaration for
pressure transducer HM 16 is also valid for HM 17.

Pin assignment
Version V0

03

(4-pin M12 component plug, viewed to contact side)

1
4

2
3

Voltage

Current (two-wire system)

1 Auxiliary power + (+UB)

1 Auxiliary power + (+UB)

2 n. c.

2 n. c.

3 Auxiliary power (0 V)

3 Auxiliary power (0 V)

4 Output signal

4 n. c.

474
4/6

Bosch Rexroth AG

Hydraulics

HM 17

RE 30269/07.05

Unit dimensions (dimensions in mm)

66,5

19

43,5

81,5 (102,5)

1)

A/F 19

Dimensions required for removing


plug-in connector
Plug-in connector without cable

12

1)

2
G1/4A

21

Pressure port G1/4 according to DIN 3852

Profiled seal according to DIN 3869, material FKM (material no. R900012502)

4-pin M12 component plug

106,5 (120,5)

1)

Version V0

475
RE 30269/07.05

Hydraulics Bosch Rexroth AG

HM 17

5/6

Accessories:

Plug-in connectors:
Technical data:

Designation

Current carrying capacity: 4 A

15

25 ... 90 C

Type of protection:

IP 67

Contacts:

CuZn

Contact surface:

Gold-plated

Housing:

TPU

M 12x1

CuZn/Ni

Wire cross-section:

4 x 0.34 mm

Envelope material:

PUR

Shield:

Not connected
on plug side

Envelope diameter:

5.0 mm

Envelope colour:

Black

27

04 POL (with 2 m cable) R900779504


04 POL (with 5 m cable) R900779503

39

FKM

Screws:

M 12x1

10,5

Bending radius for dyn.


applications:

04 POL (with 5 m cable) R900779498

15

Seal:

04 POL (with 2 m cable) R900773031

42
10,5

Temperature range:

Material no.

46

20

04 POL (without cable)1) R900773042

min. 50 mm

Connection with cable sockets with connecting cables


M12x1
1 BN

4 BK

04 POL (without cable)1) R900779509

18

30

3 BU

36

20

2 WH

4
M12x1

15

03
1)

Type of protection IP 68

476
6/6

Bosch Rexroth AG

Hydraulics

HM 17

RE 30269/07.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

477

RE 30285/01.05
Ersetzt: 09.03

Setpoint generator

1/4

Type VT-SWMA4-5

Overview of contents
Contents

Features
Page

Features

Ordering data

Preferred types

Application examples

Technical data

Unit dimensions

Potentiometer with two microswitches for one axis


Especially suitable as a setpoint generator for controller cards
and modules

478
2/4

Bosch Rexroth AG

Industrial Hydraulics

Ordering data

Type VT-SWMA4-5

RE 30285/01.05

Preferred types (available at short notice)

VT SWMA4 5

Type

Material No.

VT-SWMA4-5

0 811 405 121

Setpoint generator

Application examples
Employed for output signal 0 . . . 10 V
e.g. for actuating 2-quadrant proportional amplifiers

0 ... 10 V

Valve amplifier U //

Control by logic circuit


or switching valve

Employed for output signal 2 x 0 . . . +10 V


e.g. for actuating 2 individual single-quadrant proportional
amplifiers (proportional plug amplifiers)

0 ... +10 V (left or right)

U left (a)
U right (b)

Technical data
Mechanical displacement

max. = 30

Dead zone

centre = 5

Potentiometer resistance

2 x 1.8 k

Return

Centering spring

Microswitch

2 x change-over contacts, switch within centre

479
RE 30285/01.05

Type VT-SWMA4-5

Industrial Hydraulics

Bosch Rexroth AG

3/4

Unit dimensions (Nominal dimensions in mm)

30 // R 90 % 95 %
Switching points of microswitch

Free space
for fastening

Mounting surface

Rubber seal
(IP 65)
Rear

Terminals

U1 U2
+10 VDC= or 10 VDC=

125 250 V/5 A


Microswitch

Required space beneath console


Height: 35 mm

03

480
4/4

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA4-5

RE 30285/01.05

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

Bosch Rexroth AG reserves all rights, including industrial property rights.


We reserve all rights of disposal, such as copying and passing on to third
parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered
that our products are subject to a natural process of wear and aging.

481

RE 30287/01.05
Ersetzt: 09.03

Potentiometer

Type VT-SWMA5-5

Overview of contents
Contents

Features
Page

Features

Ordering data

Preferred types

Application example

Unit dimensions

10-speed helical potentiometer for forming setpoints


Mounted on DIN rail

1/4

482
2/4

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA5-5

Ordering data

RE 30287/01.05

Preferred types (available at short notice)

VT SWMA5 5

Type

Material No.

VT-SWMA5-5

0 811 405 164

Potentiometer

Application example
The potentiometer modules function is the formation of setpoints
which act, among other things, as input variables for Rexroth
valve amplifiers. The possible voltage ranges are
0 ... +10 V (10 revs.).
10 V ... +10 V (10 revs.).

Rexroth valve amplifiers feature a potentiometer supply


(term. b32/z32) for this purpose.
The desired potentiometer setting can be mechanically fixed.
The module can be fitted onto a DIN mounting rail or fastened
directly to a mounting plate.

Valve amplifier

Neutral

or
e. g. 0 811 405 096
or

483
RE 30287/01.05

Type VT-SWMA5-5

Industrial Hydraulics

Bosch Rexroth AG

3/4

Unit dimensions (Nominal dimensions in mm)

Supply +10 V

Setpoint

Ground 10 V

03

484
4/4

Bosch Rexroth AG

Industrial Hydraulics

Type VT-SWMA5-5

RE 30287/01.05

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

Bosch Rexroth AG reserves all rights, including industrial property rights.


We reserve all rights of disposal, such as copying and passing on to third
parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered
that our products are subject to a natural process of wear and aging.

485

RE 29755/04.05
Replaces: 07.02

Electronic signal transmitter

1/6

Type VT 10399

Series 5X
Three axes version

F 87013_d

Overview of contents

Features

Engineering guidelines

Contained within the VT 10399-5X electronic signal transmitter


are the electronic and mechanical components which are used
to convert the lever movement and the operating elements contained within the ball grip into a proportional electrical voltage.
Due to the design of the lever joint, safe operation of only one
axis is also possible.

Technical data

Features:

Cable allocation

Sensitive control due to low operating forces

Characteristic curves

Integrated evaluation electronics

Zero position, directional and dead-man contact

15 V DC supply voltage

Circuit example

Replacable gaiter

Unit dimensions

Switched off if there is a cable break in the supply cables

Contents
Features

Page
1

Ordering details

Function

Polarity protection
Options:
Dead-man switch in the hand lever
The actuation pins of the Z axis are sealed (by means of a
gaiter)
The ball grip can be deflected by 20
Can be held in any position by means of a friction brake in the
X and Y axes
Information on available spare parts:
www.boschrexroth.com/spc

Directional contacts for electrical monitoring of the hand lever


movement

486
2/6

Bosch Rexroth AG

Hydraulics

VT 10399

RE 29755/04.05

Ordering details

VT 10399

5X

*
Further details
in clear text

Three axes signal transmitter


Series 50 to 59
= 5X
(50 to 59: unchanged technical data and connection allocation)
Additional functions
Friction brakes on X and Y axes
Friction brake X axis, spring return on Y axis
Friction brake Y axis, spring return on X axis
Spring return on X and Y axes
Lever form and additional functions
Ball grip, adjustable 20
Ball grip, fixed
Ball grip, fixed with gaiter

R00 =
RXY =

= BXY
= BX0
= B0Y
= FXY

Protection to EN 60529
IP 53
IP 53
IP 65

T=
A=
=B
=C
=D

Ball grip only with direction contacts


Ball grip with proportional output 10 V
Ball grip with proportional output 10 V and two direction contacts
(can also be used as zero position contacts)

Direction contact
No contact
Contact in the
X and Y axes
ball grip with
dead-man contact
ball grip without
dead-man contact

= 80
= 90
= 9R

Function
Mechanics

Electronics

The simple robust mechanism consists of a control lever that is


mounted in a swivel bearing. Two plastic track potentiometers
are adjusted, these are orientated in relation to the associated
axis. The actuation elements in the ball grip also adjusts the
plastic track potentiometers, thereby sensitive control is also
possible in the Z axis. On request the ball grip can be steplessly deflected (max. 20) in relation to the control lever. Spring
centring returns the control lever and ball grip into the neutral
position whn the lever is released. The mechanical components
are protected by means of a gaiter.

The plastic track potentiometer is connected in series with an


impedance converter, which ensures that the control curve remains within the specified limits, even with varying loading on
the control output. The electronics also carry out other protective functions. Should a cable break in the 15V supply lines occur, then the supply to the transducer is automatically switched
off internally. The electrical connection is via multi-core screened cable.

Zero position, directional and dead-man contacts


In order to be able to electrically monitor the direction of lever
movement and the zero position, a contact can be fitted per
half axis. This contact closes when the lever is moved out of its
neutral position within the range of 5 % to 10 % (referred to
the output signal 10 V).
The transducer can also be fitted with a dead-man switch. This
is operated by pressing the upper half of the hand lever (at
right angles to the plane of installation).
When these functions are required, they are connected via a
2nd non-screened cable.

The combination of plastic track potentiometer and impedance


converter ensures that a long service life is achieved.

487
RE 29755/04.05

Hydraulics Bosch Rexroth AG

VT 10399

3/6

Engineering guidelines
Attention: If the transmitter is installed in a fully isolated manner, then the transmitter housing must be earthed by a
separate cable!

Technical data (for applications outside these parameters, please consult us!)

Elektronics
Supply voltage
Current consumption

U 15 VDC (1 %) stabilised
I Approx. 50 mA

Control outputs
Output voltage
Output current
Switched contact
Fuse

U Max. 10 V
I Max. 5 mA
2 A, max. 30 VDC (ohmic load)
IS 2 A medium blowing characteristics

Mechanics
Lever displacement angle

Approx. 20 from the spring centred position to the end


position (when operated in the X or Y directions)

Operating force

F Start value approx. 7 N


Final value approx. 16 N

Protection to EN 60529
Above the mounting plane:

See ordering details

Below the mounting plane:

IP 65

Cable length

l 600 mm

Permissible ambient temperature

25 to +70 C

Weight

m Approx. 2.0 kg

03

488
4/6

Bosch Rexroth AG

Hydraulics

VT 10399

RE 29755/04.05

Cable allocation
Colour of the connecting cable (cable 1 screened):
Supply lines:

Signal lines:

Screen:

Notes:

Colour of the connecting cable (cable 2 non-screened):

Red

+15 V

Feed cable:

Blue

Black

M0 (measuring zero)

Directional contacts:

Grey/Pink

XA

Blue

15 V

Red/Blue

XB

White

M0 (measuring zero)

Yellow

YC

Pink

X axis

Braun/Green

YD

Green

Y axis

White/Yellow

ZE

Yellow

Z axis

Yellow/Brown

ZF

Yellow/Green Housing transmitter

Dead-man contact:

Grey

Transparent

Zero position contact:

Black

X axis

Green

Y axis

White/Green

Z axis

Screen

The cable screen is not connected internally!


If the transmitter is installed in a fully isolated manner, then the transmitter housing must be connected to earth!

Characteristic curves

X axis
Y axis

20

YC
XA

Z axis
+ 10 V

Lever displacement
1

XB
YD

10 V

20 angle

12 mm

ZE

+ 10 V

1mm
1mm

ZF

10 V

12 mm

Way

489
RE 29755/04.05

Hydraulics Bosch Rexroth AG

VT 10399

5/6

Zero position, directional and dead-man contacts


Directional contact XA
Zero position contact X axis
Directional contact XB

Directional contact YC
Zero position contact Y axis
Directional contact YD
2A

Directional contact Z E
Zero position contact Z axis
Directional contact ZF

Dead-man contact

Circuit example
Supply
voltage

Supply
voltage

03
+

12 V
24 V

VT 11005
VT 11006

Proportional
amplifier

Power
supply
module

Proportional solenoids
Propor-

Directional and
zero position relays

tional
amplifier

Proportional solenoids
Proportional
amplifier

Proportional solenoids

490
6/6

Bosch Rexroth AG

Hydraulics

VT 10399 RE 29755/04.05

Unit dimensions (dimensions in mm)

20

20
20

150

20

88

2
1 Adjustable range for version B
2 Mounting face

120

12,5

3 Connecting cables (length 600 mm)

3
90
50

ZF

YD

92

108

4 x 7

YC
+10V

10V

Front

12

ZE

76,4

XB 10V

70

100

45

Front (see notch)

XA +10V

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

491

RE 29754/04.05
Replaces: 07.02

Electronic signal transmitter

1/8

Type VT 10406

Series 3X
Two axes version

F 87014_d

Overview of contents
Contents

Features
Page

Contained within the VT 10406-3X electronic signal transmitter


are the electronic and mechanical components which are used
to convert the lever movement into two independent proportional
signals. Due to the design of the lever joint safe operation of only
one axis is also guaranteed.

Features

Ordering details

Function

Engineering guidelines

Technical data

Sensitive control due to low operating forces

Cable allocation

Integrated evaluation electronics

Characteristic curves

15 V DC supply voltage

Zero position, directional and dead-man contact

Replacable gaiter

Switch in the lever

Switched off if there is a cable break in the supply cables

Circuit example

Polarity protection

Unit dimensions

7
Options:
Dead-man switch in the hand lever
Additional controls are possible via various switches fitted into
the hand lever
Can be held in any position by means of friction brakes in the
X and Y axes
The zero point may be mechanically locked

Information on available spare parts:


www.boschrexroth.com/spc

Directional contacts for electrical monitoring of the hand lever


movement

492
2/8

Bosch Rexroth AG

Hydraulics

VT 10406

RE 29754/04.05

Ordering details

VT 10406

3X

*
Further details in clear text

Two axes signal transmitter


Series 30 to 39
= 3X
(30 to 39: unchanged technical data and connection allocation)
Additional functions
Friction brakes on X and Y axes
Friction brakes on X axis, spring return on Y axis
Friction brakes on Y axis, spring return on X axis
Spring return on X and Y axes
Lever form
Hand lever
Hand lever
Hand lever
Hand lever
Hand lever
Ball lever
Ball lever
Ball lever

Additional functions
None
Push button
Rocker switch
Pressure operated switch
Rocker switch with detent
None
With dead-man contact
With mech. pull detent

Protection to EN 60529
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 53
IP 65

R00 =
RXY =
S=
K=

= BXY
= BX0
= B0Y
= FXY

Direction contact
No contact
Contact in X and Y axes
Standard
Cross-form limiting gate

=0
=1
=2
=3
=4
=5
=6
=7

Function
Mechanics

Electronics

The simple robust mechanism consists of a control lever mounted in a swivel bearing. Two plastic track potentiometers are
adjusted, these are orientated in relation to the associated axis.
When the control lever is released, springs return to its neutral
position. The mechanical components are protected by means
of a gaiter. The transmitter can be fitted with a friction brake on
both axes which makes it possible to hold the control lever in
any position. When the actuation of only one axis is permissible a cross-form of gate can be fitted. (simultaneous actuation of
both axes is thereby not possible).

The plastic track potentiometer is connected in series with an


impedance converter, which ensures that the control curve remains within the specified limits, even with varying loading on
the control output. The electronics also carry out other protective functions. Should a cable break in the 15V supply lines
occur, then the supply to the transducer is automatically switched off internally. The electrical connection is via a multi-core
screened cable.

Zero position, directional and dead-man contacts


In order to be able to electrically monitor the direction of lever
movement and the zero position, a contact can be fitted per
half axis. This contact closes when the lever is moved out of its
neutral position within the range of 5 % to 10 % (referred to
the output signal of 10 V).
The transducer can also be fitted with a dead-man switch. This
is operated by pressing the upper half of the hand lever (at
right angles to the plane of installation).
When these functions are required, they are connected via a
2nd non-screened cable.

The combination of plastic track potentiometer and impedance


converter ensures that a long service life is achieved.

493
RE 29754/04.05

Hydraulics Bosch Rexroth AG

VT 10406

3/8

Engineering guidelines
Attention: If the transmitter is installed in a fully isolated manner, then the transmitter housing must be earthed by a
separate cable!

Techicnal data (for applications outside these parameters, please consult us!)
Elektronics
Supply voltage
Current consumption

U 15 VDC ( 1 %) stabilised
I Approx. 40 mA

Control outputs
Output voltage
Output current
Switched contact
Fuse

U Max. 10 V
I Max. 5 mA
2 A, max. 30 VDC (ohmic load)
IS 2 A, medium blowing characteristics

Mechanics
Lever displacement angle

Approx. 20 from the spring centred position to the end

Operating force

F Start value approx. 7 N

position (when operated in the X or Y directions)


Final value approx. 16 N
Protection to EN 60529
Above the mounting plane

See ordering details

Below the mounting plane

IP 65

Cable length

l 600 mm

Permissible ambient temperature

25 to +70 C

Weight

m Approx. 1.8 kg

03

494
4/8

Bosch Rexroth AG

Hydraulics

VT 10406

RE 29754/04.05

Cable allocation
Colour of the connecting cable (cable 1 screened):
Supply lines:

Signal lines:

Screen:

Notes:

Red

+15 V

Black

M0 (measured zero)

Blue

15 V

White

M0 (measured zero)

Pink

X axis

Green

Y axis

Yellow/Green

Housing transmitter

Transparent

Screen

The cable screen is not connected internally!


If the transmitter is installed in a fully isolated manner, then the transmitter housing must be connected to earth!

Colour of the connecting cable (cable 2 non-screened):


Feed cable:

Blue

Directional contacts:

Grey/Pink

XA

Red/Blue

XB

Yellow

YC

Brown/Green YD
Dead-man contact:

Grey

Zero position contact:

Black

X-Achse

Green

Y-Achse

Characteristic curves
YC
XA

X axis
Y axis

20

+ 10 V

1
1

XB
YD

10 V

20

Lever displacement angle

495
RE 29754/04.05

Hydraulics Bosch Rexroth AG

VT 10406

5/8

Zero position, directional and dead-man contacts

Directional contact XA
Zero position contact X axis
Directional contact XB

Directional contact YC
2A

Zero position contact Y axis


Directional contact YD

Dead-man contact

Switch in the lever

Pressure switch and push button:

Rocker switch and rocker switch with detent:

Violet

White
2A

Violet
2A

Brown

Colour of the connection cables (cable 2 non-screened):


Feed cable:

Violet

Pressure operated switch and push button:

White

Rocker switch and rocker switch with detent:

Brown

White

03

12 V
24 V

tional

zero position relays

amplifier

Propor-

amplifier

tional

Propor-

Directional and

Power
supply
module

VT 11006

VT 11005

Supply
voltage

Proportional solenoids

Proportional solenoids

Bosch Rexroth AG

Supply
voltage

6/8
Hydraulics

496
VT 10406

Circuit example

RE 29754/04.05

497
RE 29754/04.05

Hydraulics Bosch Rexroth AG

VT 10406

7/8

Unit dimensions (dimensions in mm)


5

20

20

42

38

120

12,5

145

190

Front

90
YC +10V

XB

92

108

10V

4 x 7

XA
+10V

12

100

76,4

Front (see notch)

YD 10V

1 Hand lever
2 Ball lever
3 Mounting face
4 Connecting cables (length 600 mm)
5 Switch in lever (see ordering details)
6 Dead-man contact
7 Pull detent

03

498
8/8

Bosch Rexroth AG

Hydraulics

VT 10406

RE 29754/04.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

499

RE 29753/04.05
Replaces: 07.02

Electronic signal transmitter

1/6

Type VT 10468

Series 3X
Single axis version

F 87015_d

Overview of contents
Contents

Features
Page

Features

Ordering details

Function

Engineering guidelines

Technical data

Cable allocation

Characteristic curves

Zero position, directional and dead-man contact

Switch in the lever

Circuit example

Unit dimensions

Contained within the VT 10468-3X electronic signal transmitter


are the electronic and mechanical components which are used
to convert the lever movement into a proportional electrical
voltage.
Sensitive control due to low operating forces
Integrated evaluation electronics
15 V DC supply voltage
Replacable gaiter
Switched off if there is a cable break in the supply cables
Polarity protection
Options:
Dead-man switch in the hand lever
Additional controls possible via various switches fitted into the
hand lever
Can be held in any position by means of a friction brake
The zero point may be mechanically locked

Information on available spare parts:


www.boschrexroth.com/spc

Directional contacts for electrical monitoring of the hand lever


movement

500
2/6

Bosch Rexroth AG

Hydraulics

VT 10468

RE 29753/04.05

Ordering details

VT 10468

3X

*
Futher details in clear text

Single axis signal transmitter


Series 30 bis 39
(30 to 39: unchanged technical data and connection allocation)
Additional functions
Friction brake
Spring return
Lever form
Hand lever
Hand lever
Hand lever
Hand lever
Hand lever
Ball lever
Ball lever
Ball lever

Additional functions
None
Push button
Rocker switch
Pressure operated switch
Rocker switch with detent
None
With dead-man contact
With mech. pull detent

= 3X
R0 =
RX =

Direction contact
No contact
Contact in the X axis

=B
=F
Protection to EN 60529
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 53
IP 65

=0
=1
=2
=3
=4
=5
=6
=7

Function
Mechanics

Electronics

The simple robust mechanism consists of a control lever mounted in a swivel bearing. By deflecting the lever, the setting of a
plastic track potentiometer is changed. Dependent upon the
model, the control lever is automatically spring returned to the
neutral position or held in any position by a friction brake.
A mechanical detent can also be fitted into the hand lever. The
mechanism is protected by a rubber gaiter.

The plastic track potentiometer is connected in series with an


impedance converter, which ensures that the control curve remains within the specified limits, even with varying loading on
the control output. The electronics also carry out other protective functions. Should a cable break in the 15V lines occur,
then the supply to the electronics is automatically switched off
internally. The electrical connection is via multi-core screened
cable.

Zero position, directional and dead-man contacts

The combination of plastic track potentiometer and impedance


converter ensures that a long service life is achieved.

In order to be able to electrically monitor the direction of lever movement and the zero position, a switch can be fitted per
half axis. This switch closes when the lever is moved between
5 % to 10 % of the maximum travel (referred to the output
signal of 10 V).
The transducer can also be fitted with a dead-man switch. This
is operated by pressing the upper half of the hand lever (at
right angles to the plane of installation).
When these functions are required, they are connected via a
2nd non-screened cable.

Engineering guidelines
Attention: If the transmitter is installed in a fully isolated manner, then the transmitter housing must be earthed by a seperate
cable!

501
RE 29753/04.05

Hydraulics Bosch Rexroth AG

VT 10468

3/6

Technical data (for applications outside these parameters, please consult us!)
Electronics
Supply voltage

U 15 VDC ( 1 %) stabilised

Current consumption

I Approx. 30 mA

Control outputs
Output voltage

U Max. 10 V

Output current

I Max. 5 mA

Switched contacts

2 A, Max. 30 VDC (ohmic load)


IS 2 A, medium blowing characteristics

Fuse
Mechanics
Lever displacement angle

Approx. 20 from the spring centre position to the end position

Operating force

F Start value approx. 6 N

(when operated in the X direction)


Final value approx. 10 N
Protection to EN 60529
above the mounting plane:

See ordering details

below the mounting plane:

IP 65

Cable length

l 600 mm

Permissible ambient temperature

25 to +70 C

Weight

m Approx. 1.5 kg

Cable allocation

Characteristic curves

Colour of the connecting cables (cable 1 screened):


Supply lines:

Signal lines:
Screen:

Notes:

Red

+15 V

Black

M0 (measured zero)

Blue

15 V

White

M0 (measured zero)

Pink

X axis

Yellow/green

Housing transmitter

Transparent

Screen

The cable screen is not connected internally!


If the transmitter is installed in a fully isolated
manner, then the transmitter housing must be
connected to earth!

X axis
XA

+ 10 V

03

20

1
1

20

Lever displacement angle

Colours of the connecting cables (cable 2 non screened):


Feed cable:

Blue

Directional contacts:

Grey/Pink

XA

Red/Blue

XB

Dead-man contact:

Grey

Zero position contact:

Black

X axis

XB

10 V

502
4/6

Bosch Rexroth AG

Hydraulics

VT 10468

RE 29753/04.05

Zero position, directional and deadman contacts

Directional contact XA
Zero position contact X axis
Directional contact XB
2A

Dead-man contact

Switch in the lever

Pressure switch and push button


Violet

White
2A

Rocker switch and rocker switch with detent

White

Violet
2A

Brown

Colours of the connecting cable (cable 2 non screened):


Feed cable:

Violet

Pressure operated switch and push button:

White

Rocker switch and rocker switch with detent:

Brown

12 V
24 V

Directional and
zero position relays

Power supply
module

VT 11006

VT 11005

Supply
voltage

Proportional solenoids

Proportionalamplifier

Supply
voltage

Switching
amplifier

Switching solenoids

output

Switched signal

Supply
voltage

RE 29753/04.05
VT 10468

503
Hydraulics Bosch Rexroth AG
5/6

Circuit example

03

504
6/6

Bosch Rexroth AG

Hydraulics

VT 10468

RE 29753/04.05

Unit dimensions (dimensions in mm)

7
38

20

20

42

120

165

11

80

55
1 Hand lever
2 Ball lever

65

50

4 x 6,5
XB

XA

10V

+10V

3 Mounting face
Front

4 Connecting cables (length 600 mm)


5 Switch in lever (see ordering details)
6 Dead-man contact

90

7 Pull detent

105

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

505

RE 29 881/06.03
Replaces : 03.02

Electronic remote control for the


actuation of hydraulic axis
Type 4THES5, THEC5, THE5

Type : 4THES5 E, THE5 E, THEC5 G

Content
Functional description, section
Mechanical technical data
Electrical technical data
Safety features and guidelines of the THE5
Ordering details
Variations of ergonomic grip EC2000
Contact position within the plugs for wiring grip EC2000
4THES5 Signal
THEC5 CAN bus
THE5 Power PWM

Features
2
3
4-5
5-6
7
8
9
10-13
14-18
19-26

Specially designed for mobile machines.


Types available : Signal, CAN, Power PWM.
High mechanical robustness of hydraulic remote control
components.
Large selection of ergonomic grips with various E-contacts.
Actuator ergonomics comparable with hydraulic remote
controls.
Metallic electronic box.

03

2003
by Bosch Rexroth AG, Mobile Hydraulics, D-89275 Elchingen
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using electronic systems, in any form or
by any means, without the prior written authorisation of Bosch Rexroth AG, Mobile Hydraulics. In the event of contravention of the above provisions,
the contravening party is obliged to pay compensation.

4THES5, THEC5, THE5

1/26

RE 29 881/06.03

506

Functional description, section


Design
Remote controls type THE5 are mainly composed of a control lever
(1), a fixation body (2) and a box (3) containing the sensors and
electronic cards.

General
All types of THE5 remote controls have similar mechanics and
ergonomics. Their main differences are the integrated electronic
functions and the type of output signals.
- The remote control 4THES5 Signal needs external regulated Power
supplies for its sensors. It generates an analog voltage command
value (V).
- The CAN bus type THEC5 works in a similar manner. It periodically
generates a frame on CAN bus.
Both types of remote controls generate only low power signals. The
actuation of an electrohydraulic axis requires a further external
electronic power interface.
- The remote control THE5 Power PWM gives stabilized currents for
the direct operation of electrohydraulic proportional pressure reducing
valves. The analog Power outputs are pulse-width-modulated (PWM).
Remote controls THE5 fitted with microcontrollers ( CAN bus and

Power PWM) communicate with the PC through a serial interfaces


RS232. CAN bus interfaces enable command values to be sent to
further systems, such as Brueninghaus Hydromatik MC
microcontrollers.
Function principle
When not actuated the control lever is held in the neutral position by
the 4 return springs (8).
With deflection of control lever (1) plunger (5) pushes against return
spring (8). A position sensor is allocated to each actuation axis. Slider
(4) of the sensor fixed on plunger (5) moves upward or downward
while following the lever actuation direction. The command value
generated by the sensor is proportional to lever deflection.
A rubber grommet (6) protects the mechanical components of the
housing from contamination.

6
5

4
3

RE 29 881/06.03

2/26

4THES5, THEC5, THE5

507

Mechanical technical data (for applications outside these parameters, please consult us !)
THE5 Type

4THES5 Signal

Temperature range :
storage, ambient
operation

THEC5 CAN bus


2, 3 and 4 axis

THE5 Power
2, 3 and 4 axis

- 40 to + 85
- 30 to + 70

C
C

Resistance to vibrations and shocks

CDC 381002

Protection degree to DIN 40050

P65 - upper part


Lower part is not
tight

Box

IP65 - upper part


IP67 - lower part

IP65 - upper part


Lower part is not
tight

Zamack (aluminium alloy)

Installation

vertical

Max. permissible actuation moment at the lever


Weight

Nm
kg

10 Nm during operation
80 Nm with an exceptional, one-time loading
1,86

1,9

1,7

Characteristic data : lever control moment in function of lever deflection


Axis 1
Axis 2

Lever deflection in degree


Moment in mN.m
Lever deflection in degree
Moment in mN.m

-25
1,50
-20
1,35

0
0,60
0
0,55

25
1,50
20
1,35

03

4THES5, THEC5, THE5

3/26

RE 29 881/06.03

508

Electrical technical data (for applications outside these parameters, please consult us !)
THE5 Type

4THES5 Signal

THEC5 CAN bus


2, 3 and 4 axis

Nominal supply voltage Vbat

12V, 24V DC

Power supply

9V32V DC

Total current consumption :


Without load
Loaded, maximum value

2A

200mA

Internal fuse

5A

none

External fuse

Quantity of :
External regulated power supply

On/Off Inputs

Outputs for proportional control


of electrohydraulic pressure reducing valve (PWM)
On/Off Outputs

THE5 Power
2, 3 and 4 axis

3A

1A

2 axis : 5A
3 axis : 8A
4 axis : 10A

1 or 2
(sensors
supply)
-

1 or 2
(sensors
supply)
5
(4 buttons
+ dead man)
-

4
(direction contacts)

1
(output
initialization over)

2
(position
proportional
outputs) *
-

2
(position
proportional
outputs) *
1
1

Analog outputs (voltage)

RS 232 Interface for PC software


Interfaces for CAN bus
External regulated power supply of sensors: voltage range

2
(sensitivity + dead
man)
Up to 8
5
(output initialization
over + 4 direction
contacts)
-

1
1 (optional)

0-5V / 1mA
0-10V / 2mA

On/Off Inputs

Active input at 0V, I contact = 2mA to 7mA.


Internal pull up at +Vbat filtered

Proportional solenoid outputs :


Pulse frequency (PWM)
Current range (load dependent)

100 300Hz
02,5A

On/Off Output, max. current

1A

20mA

1A

Microprocessor

No

Yes

Yes

Electromagnetic compatibility (EMC)

qualified according to ISO standards 7637, 11452 and 13766

Protection against short circuits at supply voltage and at ground

All On/Off inputs and outputs.


Short circuit at ground or at supply voltage generates in the
sensor overvoltage that can damage it.

Protection against polarity reversal (battery power supply)

Against polarity reversal by means of a serial diode on +Vbat

Protection against polarity reversal (sensors external supply)

Against polarity reversal.

* permissible nominal current 25A /: recommended load impedance : 200kOhms under 5V.

RE 29 881/06.03

4/26

4THES5, THEC5, THE5

509

Electrical technical data (for applications outside these parameters, please consult us !)
Technical data for the grips switch EC2000
switching capacity
minimal current
maximal current

resistive load
resistive load

microswitch lifetime
resistive load at 12VDC

100mA at 12VDC or 24VDC


5A at 12VDC or 24VDC
100 to 500mA
5A

5 millions cycles
300000 cycles

resistive load at 24VDC

100 to 500mA
5A

3 millions cycles
150000 cycles

inductive load L/R=5ms at 12VDC or 24VDC

1,25A

200000 cycles

maximal contact resistance m


switching on/off with low loads
minimum voltage
minimum current strength
E-contact type

20
V
mA

12
100
high current

grip protection

IP65

switching guidelines for DC voltages

to ensure the service life of the electrical switches, we recommend the


use of free-wheeling diodes that are switched parallel to the
inductivity

Safety features and guidelines of the THE5


Safety features of the THE5 :

03
4THES5 Signal (see page 10)
The specific sensor design enables the generation of an analog signal
on a reduced voltage range compared with the supply voltage
( range 0,5V->4,5V for a 5 V power supply). Thus, a short circuit
cannot be mistaken for a correct signal.

THEC5 CAN and THE5 Power (see page 19)


Detects faults on power supply.
If a fault arises, the clock generator module ( watchdog ) switches
the microprocessor off.
Issues a periodic counter on the CAN bus to enable the detection of
the signal dynamics.

THEC5 CAN bus (see page 14)


The redundancy of the position information confirms that the
generated command value is accurate. On the "Signal" type, it is an
On/Off direction sensor redundancy. On the "Signal" type with CAN,
it is a second proportional sensor redundancy.

4THES5, THEC5, THE5

5/26

RE 29 881/06.03

510

Safety features and guidelines of the THE5


Safety guidelines for the application of the THE5 :

Application guidelines for THE5 Power PWM :

4THES5 Signal and THEC5 CAN bus


The system using the signals delivered by the remote controls THES5
and THEC5 must check the consistency of the signals and implement
the relevant corrective actions in case of failures.

Select the same supply voltage for the remote control THE5 and
the solenoids which are to be connected. I. e. 12 V solenoids for
a 12 V application and 24 V solenoids for a 24 V application.
After correcting a fault, reset the remote control by switching
the power supply off.
An emergency cut-off for the remote control power supply must
be provided for. Warning : when the remote control power
supply is switched off, the output currents are switched off
without a ramp.
Do not fit free-wheeling diodes on those of the THE5's power
lines which are connected to the inductivities of the pressure
reducing valves controlled by the THE5. Provide for suitable
protective circuit in case such lines are interrupted (relays for
instance).

THE5 Power
When a fault is detected, the power outputs are automatically
switched off. The electrohydraulic system must be designed in such a
manner that safe behaviour is guaranteed when the command value
gets equal to zero (case of translation drives).
Warning :
If the power interface to which the remote control is connected
("Signal" and "CAN" types) has no emergency switch off
system, provide for an emergency stop switch to disconnect the
power supply to the electronics. This switch must be easily
accessible to the operator. Safe braking must be provided for in
case of emergency stop (case of translation drives ).
Screen the electric cables connected to position sensors
(regulated power supply and proportional output). A low
impedance line should connect the screen with the vehicle's
ground.
Do not lay cables of low intensity currents to/from the
electronics in the vicinity of power cables.
In case of electric welding operations on the machine, unplug
the power supply battery as well as all plugs connecting the
electronics.
Ensure adequate distance of the electronics away from possible
radio equipments, to limit the magnetic field acquired by the
remote control.
Do not use in hazardous environment.
Do not direct the jet of a pressure washing unit directly at the
unit.
Fit the other inductivities of the vehicle with free-wheeling
diodes to avoid disturbances.
Remote controls must be switched off when starting the engine
of a mobile machine or vehicle.
Do not step into the dialogue phase on serial line while the
machine is working, otherwise the sending to CAN bus is
stopped.

RE 29 881/06.03

6/26

4THES5, THEC5, THE5

511

Ordering details
THE

1X /

Remote control :
2 axis controlled by the remote control electronic 42)
3 axis controlled by the remote control electronic 61)
4 axis controlled by the remote control electronic 81)
Type :
Signal
Can bus
Power PWM

S2)
C
no code

Grip range :
Ergonomic EC2000
Ergonomic EC4000
Customers
No grip

Ergonomic grip types :


Grip type E
Grip type H

E
H
no code
Z

TT, ST, VT, YT,YU


see EC4000 datasheet : RE 64562

Ergonomic grip orientation :


lever straight and grip in the direction of control port 1
lever curved by 15 in the direction of control port 2
and grip in the direction of control port 1
(pilot control unit for the left hand)
lever curved by 15 in the direction of control port 2 +
and grip in the direction of control port 1
(pilot control unit for the right hand)

03

43

23

Plugs for ergonomic wiring :


DEUTSCH sealed plug IP 67
Plug AMP MAT-N-LOK
Without plug

1)

03

5
6
no code

Remote controls CAN and Power PWM

2) Designate the Signal remote control with 2 axis maximum because the additional axis provided by grips EC4000 are not controlled by the

remote control electronic.


4THES5, THEC5, THE5

7/26

RE 29 881/06.03

512

Variations of ergonomic grip EC2000


TT

without E-contact

ST

yellow

single E-contact on
top
green

VT
black

gray

red

blue

double E-contact
with rocker swith

YT
yellow

black

gray

green

red

blue

yellow

black

gray

white

green

red

blue

brown

double E-contact
with rocker switch
single E contact on
top

YU
double E-contact
with rocker switch
single E-contact on
top
single E-contact to
the front

RE 29 881/06.03

8/26

4THES5, THEC5, THE5

513

Contact location within the plugs for wiring grip EC2000


DEUTSCH sealed plug IP 67
(ordering detail = 5)

Plug AMP MAT-N-LOCK


(ordering detail = 6)

Grip ST

Grip ST

F
2

2
1

View F

View F

cover DEUTSCH DT 04 - 2P - CE 04

cover AMP 350778 - 1


Grip VT or YT

Grip VT or YT

F
1
2
3

6
5
4

View F

View F
cover DEUTSCH DT 04 - 6P - CE 04
Identification wire
in the plug colour
1
2
3
4
5
6

red
black
gray
blue
yellow
green

cover AMP 350781 - 1

Ergonomic grip type


VT
x
x
x
x

Identification wire
in the plug colour

YT
x
x
x
x
x
x

red
black
gray
blue
yellow
green

1
2
3
4
5
6

Grip YU

Ergonomic grip type


VT
x
x
x
x

YT
x
x
x
x
x
x

03

Grip YU

5 6 7 8

4 3 2 1

F
1

View F

View F
cover DEUTSCH DT 04 - 8P - CE 04

cover AMP 350782 - 1

Identification wire identification wire


in the plug colour in the plug colour

Identification wire identification wire


in the plug colour in the plug colour
1
2
3
4
4THES5, THEC5, THE5

red
black
gray
blue

5
6
7
8

yellow
green
white
brown

1
2
3
4
9/26

red
black
gray
blue

5
6
7
8

yellow
green
white
brown

RE 29 881/06.03

514

4THES5 Signal
The remote control type 4THES5 Signal is designed to deliver
command values to both axis of the single control lever. The command
values are proportional to the movement.
This remote control requires 2 external regulated power supplies (
0-5V or 0-10V ). Such power supplies are to be provided from an
external electronics, such as Brueninghaus Hydromatik MC
microcontrollers. The power supplied directly by the battery supplies
the direction contacts ( 1A nominal ).
The proportional outputs supply a voltage ranging between 20%
and 80% of the external regulated voltage. Thanks to this voltage
limitation, the external electronic system with which the remote control
is connected is able to detect cable breaks and short circuits.
To reverse the command value generated by the remote control, one
can invert the external supplies.
Features
Electromagnetic compatibility (EMC) according to the ISO
standards 7637, 11452 and 13766.
Ergonomics similar to hydraulics ( permissible deflection angle :
axis 1 : 25 ; axis 2 : 20 ).
Life expectancy : 3 Million cycles.
Compatible with the electrohydraulic actuation module on
SX14 and SX12 directional control blocks.

Requires an external amplifier and an external regulated Power


supply to actuate proportional pressure reducing valves.
Redundancy by means of an on/off sensor working in parallel to
the proportional sensor.

4THES5 Signal - block diagram 2 axis version

Pin 12 +V battery
Pin 11 V battery
Pin 3 +V power supply sensor axis 1
Pin 1 proportional output axis 1
Pin 7 direction + axis 1
On/Off
inputs
interface

Pin 4 V power supply sensor axis 1


Pin 5 +V power supply sensor axis 2

Pin 8 direction axis 1


Pin 9 direction + axis 2
Pin 10 direction axis 2

Pin 2 proportional output axis 2

Pin 6 V power supply sensor axis 2

RE 29 881/06.03

10/26

4THES5, THEC5, THE5

515

4THES5 Signal
Pin allocation
Output connection on plug Deutsch.
Designation of the remote control plug : DT 04 - 12PA - CE 01 : 12 pins.
Designation of the machine plug : DT04-12SA-CE01; DSI material N: 08250513.
Pin number

Designation

Proportional output axis 2 (minimum load 200kOhms with 5V Power supply)

Proportional output axis 1 (minimum load 200kOhms with 5V Power supply)

+V Power supply sensor axis 1

V Power supply sensor axis 1

+V Power supply sensor axis 2

V Power supply sensor axis 2

Direction + axis 1

Direction axis 1

Direction + axis 2

10

Direction axis 2

11

V battery

12

+V battery

Outputs characteristic curves


On/Off outputs
V battery
100%

Directions
1 (2 )

Directions
1+ (2+ )

-100%

+100%

03

Angle

Proportional outputs
V sensor power supply
85%

Directions
1+ (2+ )

50%

Directions
1 (2 )

15%
-100%

4THES5, THEC5, THE5

+100%

11/26

Angle
RE 29 881/06.03

516

4THES5 Signal
Wiring : block diagram

4THE
S5

plug
Regulated power supply 5-10V
Voltage signal
EMS
module

Module battery power supply


Redondancy with
On/Off signals

fuse

battery
(12V or 24V)

Terminal connection

F
1
2
3
4
5
6

12
11
10
9
8
7

View F
cover DEUTSCH DT 04 - 12PA - CE 01

RE 29 881/06.03

12/26

4THES5, THEC5, THE5

517

4THES5 Signal

112

Unit dimensions (dimensions in mm)

86,4

03

Unit dimension in function of the grip type:


type of grip
EC2000
EC4000

4THES5, THEC5, THE5

Y
207,5
248,5

13/26

RE 29 881/06.03

518

THEC5 CAN bus


The remote control type THEC5 CAN bus makes available on a CAN
bus the information about the control lever position for each axis. It
is able to take the analog information from 1 or 2 external sensors
(e.g. EC3000 or EC4000) and send them to the CAN bus.
This remote control requires one ( or two ) external regulated power
supply(ies) ( 0-5V or 0-10V ). Such power supply are to be provided
from an external electronics such as Brueninghaus Hydromatik MC
microcontrollers. This external power supply enables the generation
of a redundant signal on each of both axis.
The power supplied by the battery supplies the electronics, which
generate an internal 5V.
The analog outputs deliver a voltage which is proportional to the
external regulated supply voltage. The external electronic system can
limit the supply voltage between 20% and 80% of its reference
voltage in order to be able to detect cable breaks or short circuits.
The remote control has 2 proportional tracks for each axis.
The first proportional track, supplied by the internal 5V, is processed
by the remote control's microprocessor which normalizes and converts
its value into a percentage. Then the percentage is issued in a CAN
frame on 1 byte plus sign.
The supply of the second proportional track is external, it can be
reversed so that the command value generated by the remote control
can also be inverted.
The remote control can simultaneously actuate 2 to 4 axis, according
to the selected type.

Features
Electromagnetic compatibility (EMC) according to the ISO
standards 7637, 11452 and 13766.
Ergonomics similar to hydraulics ( permissible deflection angle :
axis 1 : 25 ; axis 2 : 20 ).
Life expectancy : 3 Million cycles.
Card with microcontroller, CAN 2.0 compatible with identifier
coded on 11 bits.
The command values are available in standard analog shape
and on the CAN bus (digital); thanks to this redundancy the
application of the remote control is made safer.

RE 29 881/06.03

Redundancy by means of 2 proportional tracks simultaneously


actuated.
Dead man input
Output "initialization over"

14/26

4THES5, THEC5, THE5

519

THEC5 CAN bus


THEC5 CAN bus - block diagram 2 axis version
Pin 14 +V power supply
sensor axis 1
Pin 20 proportional output axis1
Pin 12 V power supply
sensor axis 1
Pin 7 +V power supply
sensor axis 2
Pin 23 proportional output axis 2
Pin 8 V power supply
sensor axis 2

Pin 5 +V battery

+5V

supply
5V
350mA

0V
+5V

converter
A-N 8 bits
converter
A-N 8 bits

K line
interface
CAN
interface
On/Off output
interface

Pin 6 V battery

Pin 15 K line interface


Pin 16, 17, 18, 19
CAN bus interface
Pin 10 output
initialization over

logics
0V
Pin 1 On/Off input 1
Pin 2 On/Off input 2
Pin 3 On/Off input 3

On/Off
inputs
interface

Pin 4 On/Off input 4


Pin 9 dead man input

THEC5 CAN bus - block diagram 4 axis version


Pin 14 +V power supply
sensor axis 1
Pin 20 proportional output axis 1
Pin 12 V power supply
sensor axis 1
Pin 7 +V power supply
sensor axis 2

03

Pin 23 proportional output axis 2


Pin 8 V power supply
sensor axis 2

Pin 5 +V battery

+5V

supply
5V
350mA

0V
+5V

converter
A-N 8 bits
converter
A-N 8 bits
converter
A-N 8 bits
converter
A-N 8 bits

Pin 21 proportional input


axis 3
Pin 22 proportional input
axis 4
K line
interface
CAN
interface
On/Off output
interface

Pin 6 V battery
Pin 11 power supply +5V
axis 3 and 4
Pin 1 On/Off input 1
Pin 2 On/Off input 2
Pin 3 On/Off input 3
Pin 4 On/Off input 4
Pin 9 dead man input

4THES5, THEC5, THE5

Pin 15 K line interface


Pin 16, 17, 18, 19
CAN bus interface
Pin 10 output
initialization over

logics
0V

On/Off
inputs
interface

15/26

RE 29 881/06.03

520

THEC5 CAN bus


Pin allocation
Sealed plug AMP Seal 23 pins.
Designation of the remote control plug : 770-728-1.
Designation of the machine plug: 770-680-1; DSI material N: 08250439.
Pin number

Designation
4THEC5 (2 axis)

8THEC5 (4 axis)

On/Off input 1

On/Off input 1

On/Off input 2

On/Off input 2

On/Off input 3

On/Off input 3

On/Off input 4

On/Off input 4

+V battery

+V battery

0V battery

0V battery

+V Power supply sensor of axis 2

+V Power supply sensor of axis 2

V Power supply sensor of axis 2

V Power supply sensor of axis 2

Dead man input

Dead man input

10

Output "initialization over"

Output "initialization over"

11

Not allocated

+V Power supply sensor of axis 3 and 4

12

V Power supply sensor of axis 1

V Power supply sensor of axis 1

13

Not allocated

V Power supply sensor of axis 3 and 4

14

+V Power supply sensor of axis 1

+V Power supply sensor of axis 1

15

Line ISO K

Line ISO K

16

CAN H

CAN H

17

CAN H

CAN H

18

CAN L

CAN L

19

CAN L

CAN L

20

Proportional output of axis 1

Proportional output of axis 1

21

Not allocated

Proportional input of axis 3

22

Not allocated

Proportional input of axis 4

23

Proportional output of axis 2

Proportional output of axis 2

Outputs characteristic curve


Proportional outputs
V sensor power supply
85%

Directions
1+ (2+ )

50%

Directions
1 (2 )

15%
-100%

RE 29 881/06.03

+100%

16/26

Angle

4THES5, THEC5, THE5

521

THEC5 CAN bus


Wiring : block diagram

THEC5

plug

CAN Bus communication

Electronical
vehicle (ECM)

PWM

Voltage signals on regulated power


supply 5-10V
PCTHE5

error display

On/Off signals

On/Off input
On/Off input
On/Off input
On/Off input
-

PC
fuse

battery
(12V or 24V)

When in operation, the programming tools must be isolated from the remote control so that the parameters are protected.

Terminal connection

Display and adjustment possibilities


All adjustment processes and display of functions, faults and systemspecific values are performed by means of a PC with software ToolSE
via the serial interface (DSI material N: 08250401).

4THES5, THEC5, THE5

17/26

RE 29 881/06.03

03

522

THEC5 CAN bus

120,9

130

104,6

Unit dimensions (dimensions in mm)

Unit dimension in function of the grip type :


type of grip
EC2000
EC4000

RE 29 881/06.03

Y
207,5
248,5

18/26

4THES5, THEC5, THE5

523

THE5 Power PWM


The remote control type THE 5 Power PWM supplies power currents
for the direct and proportional actuation of the solenoids of electrohydraulic pressure reducing valves.
The curves of the current behaviour according to lever deflection can
be programmed for each control port.
The remote control can simultaneously actuate 2 to 4 axis, depending
on the selected execution.

Features
Electromagnetic compatibility (EMC) according to the ISO
standards 7637, 11452 and 13766.
Ergonomics similar to hydraulics (permissible deflection angle :
axis 1 : 25 ; axis 2 : 20).
Life expectancy : 3 Million cycles.
Redundancy by means of an on/off sensor working in parallel to
the proportional sensor.
Dead man input
Output "initialization over"
Sensitivity input for the selection of the control curves.
Possible connection with CAN net.

03

4THES5, THEC5, THE5

19/26

RE 29 881/06.03

524

THE5 Power PWM


THE5 Power PWM - block diagram 2 axis version
Pin 3, 4 +V battery

Pin 1, 2 V battery

protection
+ relay
power supply for
power module

On/Off
outputs
interface

+5V

K line
interface

Pin 28 output direction + axis 1


Pin 29 output direction + axis 2
Pin 30 output direction axis 2
Pin 19 K line interface

0V
+5V
converter
A-N 8 bits
0V

logics

supply
5V
350mA

Pin 12 output initialization over


Pin 27 output direction axis 1

converter
A-N 8 bits

coils current
inputs
interface

On/Off
inputs
interface

Pin 5 sensitivity
input

4 PWM
outputs

Pin 10 dead man


input

Pin 13 main output 1+ axis 1


(load 2)
Pin 15 main output 1 axis 1
(load 1)
Pin 21 main output 2 axis 2
(load 4)
Pin 22 main output 2+ axis 2
(load 3)
Pin 14 main return axis 1
(return 1 and 2)
Pin 11 main return axis 2
(return 3 and 4)

THE5 Power PWM - block diagram 3 and 4 axis version


Pin 3, 4 +V battery

Pin 1, 2 V battery

protection
+ relay
power supply for
power module
+5V

0V

converter
A-N 8 bits

Pin 18 proportional
input axis 3

converter
A-N 8 bits

Pin 20 proportional
input axis 4

converter
A-N 8 bits

Pin 5 sensitivity
input
Pin 10 dead man
input

K line
interface

Pin 19 K line interface

+5V
converter
A-N 8 bits

Pin 17 power supply


+5V axis 3 and 4

Pin 12 output initialization over


Pin 27 output direction axis 1
Pin 28 output direction + axis 1
Pin 29 output direction + axis 2
Pin 30 output direction axis 2

0V

logics

supply
5V
350mA

On/Off
outputs
interface

4 PWM
outputs

4 PWM
outputs

On/Off
inputs
interface

coils current
inputs
interface
coils current
inputs
interface

RE 29 881/06.03

20/26

Pin 13 main output 1+ axis 1


(load 2)
Pin 15 main output 1 axis 1
(load 1)
Pin 21 main output 2 axis 2
(load 4)
Pin 22 main output 2+ axis 2
(load 3)
Pin 23 main output 1 axis 3 /
output 2nd 1 axis 1 (load 5)
Pin 24 main output 2 axis 3 /
output 2nd 2 axis 1 (load 6)
Pin 6 main output 1 axis 4 /
output 2nd 1 axis 2 (load 7)
Pin 8 main output 2 axis 4 /
output 2nd 2 axis 2 (load 8)
Pin 14 main return axis 1
(return 1 and 2)
Pin 11 main return axis 2
(return 3 and 4)
Pin 16 main return axis 3 /
return 2nd axis 1 (return 5 and 6)
Pin 9 main return axis 4 /
return 2nd axis 2 (return 7 and 8)

4THES5, THEC5, THE5

525

THE5 Power PWM


Pin allocation
Output connection on plug Deutsch 31 pins.
Designation of the remote control plug : HDP - 26 - 24 - 31 - PE L017.
Designation of machine plug : HDP - 24 - 24 - 31 - PE L017; DSI material N of machine plug kits : 08250514.
Pin number

Designation
6THE5 (3 axis)

4THE5 (2 axis)

8THE5 (4 axis)

V battery

V battery

V battery

V battery

V battery

V battery

+V battery

+V battery

+V battery

+V battery

+V battery

+V battery

Sensitivity input

Sensitivity input

Sensitivity input

Main output 1 axis 4 (load 7)


/ Output 2nd 1 axis 2

Not allocated

Not allocated

Not allocated

Main output 2 axis 4 (load 8)


/ Output 2nd 2 axis 2

Main return axis 4


/ Return 2nd axis 2 (return 7 et 8)

10

Dead man input

Dead man input

Dead man input

11

Main return axis 2


(return 3 et 4)

Main return axis 2


(return 3 et 4)

Main return axis 2


(return 3 et 4)

12

Output "initialization over"

Output "initialization over"

Output "initialization over"

13

Main output 1+ axis 1 (load 2)

Main output 1+ axis 1 (load 2)

Main output 1+ axis 1 (load 2)

14

Main return axis 1


(return 1 et 2)

Main return axis 1


(return 1 et 2)

Main return axis 1


(return 1 et 2)

15

Main output 1 axis 1 (load 1)

Main output 1 axis 1 (load 1)

Main output 1 axis 1 (load 1)

16

Main return axis 3


/ Return 2nd axis 1 (return 5 et 6)

Main return axis 3


/ Return 2nd axis 1 (return 5 et 6)

17

5VDC Power supply sensor of


axis 3

5VDC Power supply sensor of


axis 3 and 4

18

Proportional input of axis 3

Proportional input of axis 3

19

Line ISO K

Line ISO K

Line ISO K

20

Proportional input of axis 4

21

Main output 2 axis 2 (load 4)

Main output 2 axis 2 (load 4)

Main output 2 axis 2 (load 4)

22

Main output 2+ axis 2 (load 3)

Main output 2+ axis 2 (load 3)

Main output 2+ axis 2 (load 3)

23

Main output 1 axis 3 (load 5)


/ Output 2nd 1 axis 1

Main output 1 axis 3 (load 5)


/ Output 2nd 1 axis 1

24

Main output 2 axis 3 (load 6)


/ Output 2nd 2 axis 1

Main output 2 axis 3 (load 6)


/ Output 2nd 2 axis 1

25

Not allocated

Not allocated

Not allocated

26

Not allocated

Not allocated

Not allocated

27

Direction of axis 1

Direction of axis 1

Direction of axis 1

28

Direction + of axis 1

Direction + of axis 1

Direction + of axis 1

29

Direction + of axis 2

Direction + of axis 2

Direction + of axis 2

30

Direction of axis 2

Direction of axis 2

Direction of axis 2

31

Not allocated

Not allocated

Not allocated

4THES5, THEC5, THE5

21/26

RE 29 881/06.03

03

526

THE5 Power PWM


Outputs characteristic curve
On/Off outputs
V battery
100%

Directions
1 (2 )

-100%

Directions
1+ (2+ )

+100%

Angle

Wiring : block diagram

THE5

plug
PWM
PCTHE5

machine cable
set
error display
dead man switch
safety input
fine control 1

PC

fine control 2
-

fuse

battery
(12V or 24V)

When in operation, the programming tools must be isolated from the remote control so that the parameters are protected.

RE 29 881/06.03

22/26

4THES5, THEC5, THE5

527

THE5 Power PWM


Terminal connection

F
30
29
28

18
17
16
27

31 20
8
19
2
7
1
6
5
15
14
26

21
9
3
4
13

10

22

11 23
12
24

25

View F

cover DEUTSCH HDP - 26 - 24 - 31 - PE L017

Display and adjustment possibilities


All adjustment processes and display of functions, faults and systemspecific values are performed by means of a PC with software ToolSE
via the serial interface (DSI material N: 08250401).

03

4THES5, THEC5, THE5

23/26

RE 29 881/06.03

528

THE5 Power PWM

115

140,5

Unit dimensions (dimensions in mm)

Unit dimension in function of the grip type:


type of grip
EC2000
EC4000

RE 29 881/06.03

Y
207,5
248,5

24/26

4THES5, THEC5, THE5

529

THE5 Power PWM

Y3

Y1=Y2
Yd

Xd

X1 X2 X3

Xf 100%

t tF

tt R
I max
I max

answer

command
value

time

%
Yf

03
Yd

Xd

lever angle

Xf

%
100%

current

Standard programming :
If there are no special request for parametering when a THE5 remote
control is ordered then a remote control with standard parametering
is supplied.
This standard parametering is suitable for the control of the solenoids of the pressure reducing valves FT DRE 2K 12V, DRE4 12V (max.
current : 1.8 A).
standard parametering of the operating curve :
Jump at start
: Xd = 10 Yd = 40
Jump at end
: Xf = 100 Yf = 100
Number of segments : 1
standard parametering of the ramps :
ramp up
: tR = 1s
ramp down
: tF = 2s
max. current
: Imax = 1,8A
min. current
: Imin = Yd

Yf

current

Programming of a ramp :
Each control curve has two ramp values. One value (ramp "Up")
determines the maximum acceleration value; the other value (ramp
"Down") determines the maximum deceleration value. The ramp
times result from the basic time of 28ms, multiplied by the
programmable ramp factor. The sequence of the maximum current
equals :
Imax / tR bzw. Imax / tF
ramp parametering :
ramp up
: tR = 0 to 7s
ramp down
: tF = 0 to 7s
max. current
: Imax = 2,0A

100%

current

Programming of an operating curve :


The control curves of each output can be determined through 2 to 5
points whereby these reference points in the X-axis are calculated
through percentage values of the lever angle and in the Y-axis through
percentage current values.
If the programmed value for Yf is not 100%, the programme
automatically carries out a jump to 100% after reaching the value
for Yf.
parametering of the control output curve :
Jump at start
: Xd = 10 Yd = 20
Jump at end
: Xf = 85 Yf = 85
Number of segments : 4
Input of the segments
Point no. 1
: X1 = 40 Y1 = 35
Point no. 2
: X2 = 55 Y2 = 35
Point no. 3
: X3 = 60 Y3 = 55

command
value

answer

Yd
35%

time
4THES5, THEC5, THE5

25/26

RE 29 881/06.03

530

THE5 Power PWM


Possible programming of the operating curves :
Example : THE5 (2 axis, 8 parameters)
Marked output
on housing
1+
2
1
2+

on

fine control
off

Axis
1
2
1
2

2
on

on

off

off

main axis
1

1+
2+

off
fine control
on

The horizontal and vertical arrows represent the control axes which
offer the THE5 models.
Each arrow tip represents an electrical output. The diagrams illustrate
the parametering allocated to the outputs. Each output has two
diagrams allocated, i.e. the parametering "fine control OFF" and the
parametering "fine control ON".

Bosch Rexroth AG
Mobile Hydraulics
Glockeraustrae 4
89275 Elchingen - Germany
Telefon 0 73 08 / 820
Telefax 0 73 08 / 72 74
eMail documentation@rexroth.de
Internet www.boschrexroth.de

RE 29 881/06.03

The THE5 remote controls are intended for the control of pressure
reducing valves types FT DRE2K and DRE4K.
Through appropriate programming the THE5 can be matched for the
control of other solenoids (1 type per axis).

Bosch Rexroth DSI SAS


BP 101 - 91, bd Irne Joliot-Curie
69634 Vnissieux cdex - France
Tl. 04 78 78 52 52
Fax. 04 78 78 52 26 - Tlex 380 852
Internet www.boschrexroth.fr

26/26

The data specified above only serve to describe


the product. No statements concerning a
certain condition or suitability for a certain
application can be derived from our information.
The details stated do not release you from the
responsibility for carrying out your own
assessment and verification. It must be
remembered that our products are subject to a
natural process of wear and ageing.

4THES5, THEC5, THE5

531
RE 00112-04

Hydraulics Bosch Rexroth AG

Electronic accessories

Type

Series

Data
sheet no.

Connection adapter

VT10812

2X

30105

533

Enclosed card holder

VT12302

3X

30103

537

19racks

VT19101, VT19102,
VT19103, VT19110

1X

29768

539

Card holder

VT3002

2X

29928

547

Designation

Page

Racks and card holders

01

Power supply and stabilising units


Compact power supply units

VT-NE30 bis VT-NE32

1X

29929

551

Power supply module

VT11006

1X

29729

555

Capacitor module

VT11073

1X

29750

559

Hydrocontrol electronics

SYHCE

2X

57901

563

Controlled system simulator for


the VT-HNC100-1-2X digital axis control

VT-HNC100DEMO

2X

30133

571

Test and demonstration unit for digital electronic cards

VT-DVT-1

1X

29690

575

Test adapter (11P+PE) for OBE

VT-PA-1

30067

579

Test adapter (6P+PE) for OBE

VT-PA-2

30068

581

Test adapter for electric amplifiers

VT-PA-3

30070

583

Current-measuring test adapter

VT-PA-5

30073

585

Test box I

VT-PE-TB1

30063

589

Test box II

VT-PE-TB2

30064

593

Test box III

VT-PE-TB3

30065

597

Service case with test unit for proportional valves


and their control electronics

VT-PPV-1

1X

29687

601

Service case with test unit for servo-valves


without integrated electronics

VT-SYTSY-1

1X

29681

609

Service case with test unit for servo and proportional valves
with integral electronics (OBE)

VT-VETSY-1

1X

29685

615

Line connectors for valves and sensors

08008

627

Cable sockets for controlling electrically operated valves


and sensors

08006

639

29761

653

Test and service units

03

04

Plug in connectors

04

Other accessories
f/U converter and monitoring electronics FUW1

VTS0102

1X

06

532
Bosch Rexroth AG

Hydraulics

RE 00112-04

533

RE 30105/06.05
Replaces: 08.03

Connection adapter

1/4

Type VT 10812

Series 2X

H5397_d

Table of contents

Features

Features

VT 10812 connection adapaters are used as connecting element


between Euro-racks and electronic cards in Euro-format.

Ordering code

VT 10812-2X/32D connection adapters consist of:

Contents

Unit dimensions

Page

2 and 3

32-pin female multi-point connector and


32-pin terminal strip (both a/c assigned; form D)
VT 10812-2X/48F connection adapters consist of:
48-pin female multi-point connector and
48-in terminal strip (b/d/z assigned; form F)
VT 10812-2X/64G connection adapters consist of:
64-pin female multi-point connector and
64-pin terminal strip (f/d/b/z assigned; form G)

04

534
2/4

Bosch Rexroth AG

Hydraulics

VT 10812

RE 30105/06.05

Ordering code

VT 10812

2X

*
Further details in clear text

Connection adapter
Series 20 to 29
= 2X
(20 to 29: unchanged installation dimensions and pin assignment)

32D =
48F =
64G =

Unit dimensions (dimensions in mm)

Adapter, 32-pin, form D


Euro-rack

6TE
(30,1)
c

a
2
4

Electronic card

95

2
4

32

32

7
35

32-pin, form D
48-pin, form F
64-pin, form G

535
RE 30105/06.05

Hydraulics Bosch Rexroth AG

VT 10812

3/4

Unit dimensions (dimensions in mm)


Adapter, 48-pin, form F

Euro-rack

2
4

2
4

Electronic card

95

2
4

10TE
(45,32)

32

32

32

7
35

Adapter, 64-pin, form G


3

2
4

2
4

2
4

Electronic card

95

2
4

8TE
(40)

Euro-rack

32 32 32 32

04

7
56

536
4/4

Bosch Rexroth AG

Hydraulics

VT 10812

RE 30105/06.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

537

RE 30 103/03.03
Replaces: 02.97

Enclosed card holder


Type VT 12 302

H/A 4424/94

Series 3X

VT 12 302-3X

Overview of contents
Contents
Features
Ordering details
Function
Technical data
Unit dimensions

Features
Page
1
1
1
2
2

Housing made of colourless chromated steel sheet


Separate earthing screw
Connections via special terminal block
Suitable for amplifier cards with a terminal strip
to DIN 41 612, forms F or G
Recommended for digital valve amplifiers
and accessory cards, e.g. VT 12 350, VT-HACD, VT-VPCD
VT 12 352, VT-SWKD-1, VT-VRPD and VT-VSPD

Ordering details
VT 12 302 -3X/

*
Further details in clear text

Enclosed card holder


Series 30 to 39
(30 to 39: unchanged technical data and pin allocations)

= 3X

Function

04

The enclosed card holders type VT 12 302 makes assembly and wiring
of the individual Euro format (100 x 160 mm) electronic cards easy.
It has a front plate width of 8 TE. Due to its solid construction (tested
to EN 60 068-2-27, DIN IEC 68-2-6

and DIN IEC 68-2-36) the card holder can be used outside of a
switching cabinet. The enclosed form makes possible an EMV
protection to EN 61 000-4-2.

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

VT 12 302

1/2

RE 30 103/03.03

538

Technical data (for applications outside these parameters, please consult us!)
U

Terminal voltage to VDE 0110 C

Max. 125 VAC

Current loading
Cross-section connection:

Max. 4 A
0.14 to 2.5 mm2
0.14 to 1.5 mm2
24 to 12

Rigid
Flexible
AWG (to EN 60 204, part 1)

Connection type

64-pin spring contact strip, DIN 41 612, form G


for electronic cards with terminal strips, forms F or G

Pin allocation:

For terminal strips form F


For terminal strips form G

Even numbered rows d/b/z


Even numbered rows f/d/b/z

Housing dimensions (W x H x D)

10 TE x 3 HE X 208 mm

Permissible ambient temperature range

20 to + 70 oC

Weight

1.250 kg

Unit dimensions (dimensions in mm)


208

25,4

7,5

4x5

z4 z6

z8 z20 z12 z14 z16 z18 z10

63

z2

z22 z24 b26 z28 f2 d20 d22 d26 b26 b28

b2 b4 z20 b6 b8 z20 b10 b12 z20 z32

300

b14 b16 z20 b18 b20 z20 b22 b24 z20 z32

d2 d4 d6

d8 d10 d12 d14 d16 d18 b28

b30 b32 b28 d24 d28 z20 d30 d32 z30 z32

f6 f8 f10 z20 f12 f14 f16 f18 z32

75

f4

z20 f20 f22 f24 f26 z20 f28 f30 f32 z32

7,5

Earthing screw M4

56

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
E-mail: info@boschrexroth.co.uk

RE 30 103/03.03

2/2

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application can
be derived from our information. The details stated
do not release you from the responsibility for
carrying out your own assessment and verification.
It must be remembered that our products are
subject to a natural process of wear and ageing.

VT 12 302

539

RE 29768/06.05
Replaces: 10.02

19racks

1/8

Type VT 19101, VT 19102, VT 19103, VT 19110

K4804-4_d

19 rack, VT 19101

Series 1X

K4804-18_re_d

19 rack, VT 19101
(view: rear panel with plugs)

Overview of contents
Contents

Page

Features

Ordering details

Unit dimensions: terminal plug and plug housings


Unit dimensions

2
3 to 7

04

Information on available spare parts:


www.boschrexroth.com/spc

540
2/8

Bosch Rexroth AG

Hydraulics

VT 19101, VT 19102, VT 19103, VT 19110

RE 29768/06.05

Features
The 19 racks, VT 19101, VT 19102, VT 19103 and VT 19110
accept electronic assemblies in Euro-card format and they can
be fitted into 19 electronic cabinets and housings.
They conform with DIN 41494 and IEC 297-3.

Standard connection plug coding


Plug pre-assembly is possible
Or:

Designed to VDE 0100/12.65-4


Installation width; 84 pitch (TE) at 5.08 mm

VT 10812 connection adaptor (see RE 30105)


for magazines without rear wall

Designs of up to 3 x 3 height units (HE)


at 44.45 mm for Euro-cards of 100 x 160 mm
and 100 x 220 mm

Further options are:


Version with handles

Electrical shock protection via a cover plate

Recess card front

Sealed wiring space


Vibration proof version (DB acceptance)

Screwed or earthed card guide rails for


loadings caused by vibration

Optional outlets to cabinet wiring:

HF proof design

Hinged rear panel with:

Rear panel with plugs instead of a blank rear wall for


type VT 19102

140 signal connection terminals on 10 plugs with 3 HE


(max. connection cross-section 2.5 mm2)
Separate terminal block for the supply voltage with
10 terminals (max. connection cross section 6 mm2)

Blank rear panel


Plug housing

Ordering details
VT 191_ _
1 x 3 HE; card dimensions 100 x 160 mm
= 01
2 x 3 HE; card dimensions 100 x 160 mm
= 02
3 x 3 HE; card dimensions 100 x 160 mm
= 03
1 x 3 HE/2 x 3 HE; card dimensions 100 x 160/220 mm
(bus board magazine)
= 10
Series 10 to 19
= 1X
(10 to 19: unchanged installation and connection dimensions)

1X

*
Further details (options) in clear text

1=
2=

3=
5=
6=

Magazine nominal depth


For VT 19101 to VT 19103
(card dimensions 100 x 160 mm):
160 mm (without rear panel)
220 mm (with rear panel)
For VT 19110
(card dimensions 100 x 160/220 mm):
220 mm (bus magazine, 3 HE)
360 mm (bus magazine, 3 HE)
360 mm (bus magazine, 6 HE)

Unit dimensions: terminal plug and plug housings (dimensions in mm)

18,2

70

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Plug housing (option)

71

Coded terminal plug

47,5

Width approx. 19 mm

1
2
3
4
5
6
7
8
9
10
11
12
13
14

4,4

X11

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X12

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X13
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X14

X15
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X16
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X17
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X18
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X19
X100
2
3
4
5
6
7
8
9
10

Spannungsversorgung

Versorgungberwachung

PE

L1

120,6

57,15

84 TE x 5,08 = 426,7

1
2
3
4
5
6
7
8
9
10
11
12
13
14

(239) 290

(245,5)

175,4 (235,4)

3
46

VT 19101, VT 19102, VT 19103, VT 19110

1
2
3
4
5
6
7
8
9
10
11
12
13
14

482,6

449
465,1

84 TE x 5,08 = 426,7

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

Handles
(option)

X10

Nominal depth 160 (220)

RE 29768/06.05

541
Hydraulics Bosch Rexroth AG
3/8

Unit dimensions: VT 19101-1X (dimensions in mm)

Plug and plug housing


(only possible with a depth
of 220)

132,5 (3HE 0,85)

M4 internal
earth bolts

128,4 (3 HE)

04

The u numbers indicate the location of the cards within the magazine.

The first digit of the u number and the plug number gives the tier location.

4,4

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X11

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X12

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X13

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X14
1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X16
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X17
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X18
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X19
X100
1
2
3
4
5
6
7
8
9
10

Spannungsversorgung

Versorgungberwachung

PE

L1

3
46

VT 19101, VT 19102, VT 19103, VT 19110

132,5 (3HE 0,85)

128,4 (3 HE)

84 TE x 5,08 = 426,7

X15

(239) 290

(245,5)

175,4 (235,4)

Nominal depth 160 (220)

Hydraulics

482,6

120,6

57,15

465,1

120,6

57,15

449

132,5 (3HE 0,85)

84 TE x 5,08 = 426,7

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

Bosch Rexroth AG

X10

Nominal depth 160 (220)

4/8

542
RE 29768/06.05

Unit dimensions: VT 19102-1X (dimensions in mm)


Handles
(option)

Plug and plug housing


(only possible with a depth of 220)

M4 internal
earth bolts

128,4 (3 HE)

The u numbers indicate the location of the cards within the magazine.

The first digit of the u number and the plug number gives the tier location.

4,4
X12
1
2
3
4
5
6
7
8
9
10
11
12
13
14

X13

X13

X14

X14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X15

X15

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X16

X16

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X17

X17

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X18

X18

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X19
1
2
3
4
5
6
7
8
9
10

X100

1
2
3
4
5
6
7
8
9
10

X100

65

65

65

80

80

80

Versorgungberwachung

Versorgungberwachung

PE

Spannungsversorgung

L1
N

75

75

75

Spannungsversorgung

PE

L1

70

70

70

(239) 290

(245,5)

175,4 (235,4)

Nominal depth 160 (220)

Nominal depth 160 (220)

46

Hydraulics Bosch Rexroth AG

128,4 (3 HE)

84 TE x 5,08 = 426,7

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

482,6

465,1

449

60

60

60

X19

55

55

55

128,4 (3 HE)

1
2
3
4
5
6
7
8
9
10
11
12
13
14

50

50

50

57,15

X11

45

45

45

120,6

57,15

1
2
3
4
5
6
7
8
9
10
11
12
13
14

40

40

40

120,6

57,15

X12

35

35

35

120,6

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

30

30

30

132,5 (3HE 0,85)

84 TE x 5,08 = 426,7

25

25

25

132,5 (3HE 0,85)

X10

X11

20

20

20

132,5 (3HE 0,85)

1
2
3
4
5
6
7
8
9
10
11
12
13
14

X10

15

15

15

VT 19101, VT 19102, VT 19103, VT 19110

1
2
3
4
5
6
7
8
9
10
11
12
13
14

1
2
3
4
5
6
7
8
9
10
11
12
13
14

10

10

10

Nominal depth 160 (220)

RE 29768/06.05

543
5/8

Unit dimensions: VT 19103-1X (dimensions in mm)

Handles
(option)

Plug and plug housing


(only possible with a depth of 220)

M4 internal
earth bolts
128,4 (3 HE)

04

The u numbers indicate the location of the cards within the magazine.

The first digit of the u number and the plug number gives the tier location.

544
6/8

Bosch Rexroth AG

Hydraulics

VT 19101, VT 19102, VT 19103, VT 19110

RE 29768/06.05

Unit dimensions: VT 19110-1X/3 und VT 19110-1X/5 (dimensions in mm)

235,4 (294,4)

Nominal depth 220 (360)

46

Handles
(option)

132,5 (3HE 0,85)


120,6

482,6

449
465,1

84 TE x 5,08 = 426,7

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

57,15

4,4

The u numbers indicate the location of the cards within the magazine.
The first digit of the u number gives the tier loacation.

545
RE 29768/06.05

Hydraulics Bosch Rexroth AG

VT 19101, VT 19102, VT 19103, VT 19110

7/8

Unit dimensions: VT 19110-1X/6 (dimensions in mm)

5
4,4

482,6

57,15

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

120,6

57,15

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80

120,6

449
465,1

132,5 (3HE 0,85)

84 TE x 5,08 = 426,7

132,5 (3HE 0,85)

235,4 (294,4)

Nominal depth 220 (360)

Nominal depth 220 (360)

46

Handles
(option)

The u numbers indicate the location of the cards within the magazine.
The first digit of the u number gives the tier loacation.

04

546
8/8

Bosch Rexroth AG

Hydraulics

VT 19101, VT 19102, VT 19103, VT 19110

RE 29768/06.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

547

RE 29 928/11.03
Replaces: 02.03

Card holder
Typs VT3002

1/4

Series 2X

H/A 4842/93

Overview of contents
Contents

Features
Page

Features

Card holders allow the simple installation and wiring of individual electronic cards in Euro format, e.g. in switching cabinets

Ordering details

Can be screwed on or snapped onto DIN rails

Technical data

Installation guidelines

Vertical mounting onto a DIN rail, possible with an additional


adaptor (included within the scope of supply)

Unit dimensions

Stable base
Card locking and releasing by lever operation

Power supply unit:

Connection via screw terminals

Type VT-NE30-1X, see RE 29 929


Compact power supply unit 115/230 VAC 24 VDC, 70 VA

Ordering details
04
VT3002

2X

Card holder
Further details in clear text
Series 20 to 29
(20 to 29: unchanged technical data
and pin allocation)

= 2X

15H =
32D =
48F =
64G =

15-pin spring contact strip, form H


32-pin spring contact strip, form D
48-pin spring contact strip, form F
64-pin spring contact strip, form G

548
2/4

Bosch Rexroth AG

Industrial Hydraulics

VT3002 RE 29 928/11.03

Technical data (for applications outside these parameters, please consult us!)
Terminal voltage to VDE 0110 C
Current loading capacity

U Max. 125 VAC

VT 3002-2X/15H

I 15 A

VT 3002-2X/32D

I 4A

VT 3002-2X/48F

I 4A

VT 3002-2X/64G

I 3A
A Screw terminals max. 4mm2, (form H - 6 mm2)

Cross-section connection
Connection type:
(socket connection)

Pin allocation:

VT 3002-2X/15H

15-pin spring contact strip, form H, DIN 41612

VT 3002-2X/32D

32-pin spring contact strip, form D DIN 41612

VT 3002-2X/48F

48-pin spring contact strip, form F DIN 41612

VT 3002-2X/64G

64-pin spring contact strip, form G DIN 41612

VT 3002-2X/15H

Even numbered, rows d/z

VT 3002-2X/32D

Even numbered, rows a/c

VT 3002-2X/48F

Even numbered, rows d/b/z

VT 3002-2X/64G

Even numbered, rows f/d/b/z

Permissible ambient temperature range

20 bis +70C

Weight

m 0,5 kg

Installation guidelines
Push the yellow lever down and insert the card completely.
To withdraw the card you have to operate the detented lever
which releases the card enabling it to be withdrawn.

The connection profile between the two card guides can be


removed or snapped into place on the other side to allow the
connection of cables.

By moving the
spring it is possible to turn through
90 and refit.
Card holder connection types H 15-pin; D 32-pin and

Card holder connection type G 64-pin

F 48-pin

only horizontal mounting possible

Card guide

Card locking mechanism

04

2 4 6 8 1012 14161820 22242628 30 32

2 4 6 8 1012 14161820 22242628 30 32

2 4 6 8 1012 14161820 22242628 30 32

2 4 6 8 1012 14161820 22242628 30 32

f
d
b
z

177
95

8
10

12
14

220 1)

2 4 6 8 1012 14161820 22242628 30 32

16

127
140
140

127
20

140

127

22 18

127

24 28
26

140

32

d
b
z
b
2 4 6 8 1012 14161820 22242628 30 32

2 4 6 8 1012 14161820 22242628 30 32

2 4 6 8 1012 14161820 22242628 30 32

2 4 6 8 1012 14161820 22242628 30 32

30

72

c
a
a

z
d

Dim. with top-hat rail and Eurocard 100 x 160 mm

1)

40

4,2 (2x)

63
63
63

40
4,2 (2x)
40
4,2 (2x)
40
4,2 (2x)

VT 3002-2X/48F
VT 3002-2X/32D
VT 3002-2X/15H

3/4
Industrial Hydraulics Bosch Rexroth AG
RE 29 928/11.03 VT3002

549

Unit dimensions (in mm)

VT 3002-2X/64G

1,5

550
RE 29 928/11.03 VT3002

Industrial Hydraulics Bosch Rexroth AG

4/4

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

2003 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


All rights reserved. No part of the document may be reproduced or stored,
processed, duplicated or circulated using electronic systems, in any form
or bymeans, without the prior written authorisation of Bosch Rexroth AG,
Industrial Hydraulics. In the event of contravention of the above provisions,
the contravening party is obliged to bay compensation.
The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The details stated do not release you
from the responsibility for carrying out your own assessment and verification. It must be remembered that our products are subject to a natural
process of wear and ageing.

551

Compact power supply units

RE 29929/03.05
Replaces: 10.02

1/4

VT-NE30, component series 2X


VT-NE31, component series 1X
VT-NE32, component series 1X

H5348

Table of contents
Contents
Features

Features
Page
1

Ordering code

Technical data

Terminal assignment

Unit dimensions

Power supply unit VT-NE30 (unipolar output voltage):


For the voltage supply of amplifiers for proportional valves
For the voltage supply of proportional valves with
integrated electronics
Power supply unit VT-NE31 (bipolar output voltage):
For the voltage supply of amplifiers for servo-valves
Power supply unit VT-NE32 (unipolar output voltage):
Same function as power supply unit VT-NE30
In addition, regulated output voltage for the supply of closedloop control or evaluation electronics or accessory
components such as pressure transducers, position
measuring systems
Compact design, connection via terminal strip
Unregulated output voltages (filtered);
with VT-NE32 additionally regulated output voltage
Vibration resistance according to DIN IEC 68, insulation testing according to VDE 0113
Short-circuit protection by miniature fuses in output circuits;
with VT-NE32 cut-off of the regulated output voltage after
approx. 1.5 s in the case of overloading or short-circuit; restart
by pressing the reset key
Can be screwed on or snapped onto hat rail EN 60715
LED indicator lamps
Conformity with EC Directives (CE mark)

04

552
2/4

Bosch Rexroth AG

Industrial Hydraulics

RE 29929/03.05

VT-NE30, VT-NE31, VT-NE32

Ordering code
VT
Compact power supply unit, bipolar
Compact power supply unit, unipolar and regulated

1X

= NE31
= NE32

Further details in clear text


1X =

VT
Compact power supply unit, unipolar

2X

Series 10 to 19
(10 to 19: unchanged technical data and pin
assignment)

= NE30

Further details in clear text


2X =

Series 20 to 29
(20 to 29: unchanged technical data and pin
assignment)

Technical data (for applications outside these parameters, please consult us!)
VT-NE30
Filtered
Operating voltage

VT-NE31

VT-NE32

Output 1

Output 2

Output 1

Output 2

Filtered

Filtered

Filtered

Filtered

25 W

U 230 VAC 10 % or 115 VAC 10 %

Frequency

f 47 bis to Hz

Output

PO

108 W

7W

7W

60 W

UO

+32 VDC 1)

+27 VDC 1)

27 VDC 1)

+30 VDC 1)

+24 VDC

UO

1)

1)

1)

1)

+24 VDC

Output voltage (at U = 230 VAC):


No load
Full load

+26 VDC

+24 VDC

24 VDC

+25 VDC

Load current

Imax

4A

0.25 A

0.25 A

2.5 A

1A

Residual ripple content (full load)

Ueff

< 3.5 VAC

< 3 VAC

< 3 VAC

< 3 VAC

< 50 mVAC

8AT

0.8 A M

0.8 A M

0.8 A T

See features

Fuse

IF

mm2

Connection cross-section

A max. 4

Permissible ambient temperature range

20 to +50 C

Storage temperature range

20 to +70 C

Weight

1)

3.1 kg

In the case of deviations of 10 % from operating voltage


U = 230 VAC, the output voltage UO changes by 10 %.

Terminal assignment

1.3 kg

2.4 kg

Note:
For details regarding environment simulation testing in the
fields of EMC (electromagnetic compatibility), climate and
mechanical stress, see RE 29929-U (declaration on environmental compatibilty).

Connection of operating voltage


230 VAC

115 VAC

Compact power supply units VT-NE30 to VT-NE32 are ready


for connection for an operating voltage of 230 VAC.
For screwed mounting, remove the plate for hat rail mounting.
0 115 0 115

0 115 0 115

553
3/4

Industrial Hydraulics Bosch Rexroth AG

VT-NE30, VT-NE31, VT-NE32

RE 29929/03.05

Unit dimensions (nominal dimensions in mm)


4th connection on the secondary side with VT-NE30 and VT-NE32 only

140,0 (VT-NE30)
120,0 (VT-NE31)
124,0 (VT-NE32)

5th and 6th connection on the secondary side with VT-NE31 only

4 x long hole
4.8 x 9

Top view VT-NE32

Top view VT-NE30

0 115 0 115

82

102

87
102

0 115 0 115

VT-NE30

+ VT-NE32

5,8 x 9
84
64

96

85

Top view VT-NE31

+24 0 24 VT-NE31

56
78
81

04
70

59,5

47,5

0 115 0 115

554
4/4

Bosch Rexroth AG

Industrial Hydraulics

VT-NE30, VT-NE31, VT-NE32

RE 29929/03.05

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

555

RE 29729/07.05
Replaces: 02.03

Power supply module

1/4

Typ VT 11006

Series 1X

F87163_d

Table of contents
Contents

Features
Page

Features

Technical data

Block circuit diagram

Ordering code

Terminal assignment

Unit dimensions

VT 11006-1X power supply modules supply two stabilised


voltages of 15 V. They are used to supply external, electrical
consumers.
Special features:
Switched-mode power supply unit
Reverse voltage protection
Function monitoring by means of LED lamps
Output voltages electrically isolated from operating voltage

04

556
2/4

Bosch Rexroth AG

Hydraulics

VT 11006

RE 29729/07.05

Technical data (For applications outside these parameters, please consult us!)
Operating voltage

UB

21.5 Veff to 35 Veff

Three-phase bridge (winding)

21.5 V to 35 V

Full bridge (winding)

20 V to 24 V

(with external smoothing capacitor only, 2200 F per module)


P

10 VA

UO

15 V (1 %)

Power consumption
Output voltage
Residual ripple content (referred to the nominal output voltage value)
Output current
Temperature range
Weight

<1 %
I

max. 200 mA

25 to +70 C

~0.13 kg

Block circuit diagram

+UB

0V

+15 V

0V

15 V

Ordering code
VT 11006
24 V power supply module

1X

*
Further details in clear text

1X =
Series 10 to 19
(10 to 19: unchanged installation and connection dimensions)

557
RE 29729/07.05

Hydraulics Bosch Rexroth AG

VT 11006

3/4

Terminal assignment

Operating voltage UB

+UB

15 V

0V

0V

n. c.

+15 V

Notes
The power supply module is not resistant to sustained shortcircuit!
In the case of overloading of one output voltage, the second
output voltage is reduced as well!

In the case of continuous operation of several adjacent modules and temperatures higher than 40 C, a minimum space
of 20 mm must be maintained between the modules!

Unit dimensions (dimensions in mm)

Top hat rail to


EN 60715

79

4 5 6

1 2 3

85,5

25

04

558
4/4

Bosch Rexroth AG

Hydraulics

VT 11006

RE 29729/07.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

559

RE 29750/06.05
Replaces: 02.03

Capacitor module

1/4

Type VT 11073

Series 1X

F88005_d

Table of contents
Contents

Features
Page

Features

Supplementary information

Ordering code

Technical data

Pin assignment and block circuit diagram VT 11073

Terminal assignment

Unit dimensions

This capacitor module is used for smoothing operating voltages


for supplying various amplifier modules that control proportional
and servo-valves.
Features:
Capacitors
Polarity reversal diode
Fuse
Overvoltage protector
LED indicator for output voltage

Supplementary information
The capacitor module may only be wired when disconnected
from the power supply!
In the case of polarity reversal of operating voltage
short-circuit!
Do not install near power cables!

Information on available spare parts:


www.boschrexroth.com/spc

04

560
2/4

Bosch Rexroth AG

Hydraulics

VT 11073

RE 29750/06.05

Ordering code

VT 11073

1X

Capacitor module
Series 10 to19

= 1X

(10 to 19: unchanged installation and connection dimensions)


Further details in clear text

Technical data
U0

36 V DC

Capacitance

C1/2

2 x 3300 F

Reactance coil

L1/2

18 H

IF

6,3 A MT

25 C bis +70 C

~0,13 kg

Operating voltage

Fuse
Overvoltage protector:

VDR 35 V / 1 mA

Permissible ambient temperature


Weight

Pin assignment and block circuit diagram VT 11073


Output voltage
UO

Operating voltage
+U0
Si

1
L1

L0

L0

6,3 A

power

C1

C2

L2

L0

L0

561
RE 29750/06.05

Hydraulics Bosch Rexroth AG

VT 11073

3/4

Terminal assignment

UO Output voltage

0V

0V

0V

0V

Unit dimensions (dimensions in mm)

Carrier rail TH 35/7,5


to EN 60715

4 5 6
Rexroth

VT 11073

79

6,3 A

power
1 2 3

85,5

25

04

562
4/4

Bosch Rexroth AG

Hydraulics

VT11073

RE 29750/06.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

563

RE 57 901/11.02
Replaces: 02.02

Hydrocontrol electronics HCE


for the closed loop control and monitoring of
hydraulic servo axis used in testing applications

HAD 6836/01

Hydrocontrol electronics HCE


Type SYHCE, Series 2X

Hydrocontrol electronics SYHCE1-2X/...

Overview of contents
Contents
Features
Ordering details
Technical data
Modules
Unit dimensions
Function and operating
Interfaces

Features
Page
1
2
3 and 4
4
4
5
6 and 7

Manual operation via the front mounted task field or menu


guided operation using a PC via a serial interface or field bus
Digital controller, which can be switched over between position
and force or other control variables, with integrated set-up
functions and closed loop amplitude control which can be cutin
Standard monitoring of position and force limiting values
Control of a sequencing module
Command value dynamics up to 100 Hz
Coupling to a PC via a field bus or AD/DA, I/O
Interface to software tools, e.g. LabView
or CAESAR -LAB

Application areas
Closed loop control and monitoring of hydraulic servo cylinder
axis or hydraulic motors with valve controls
For use with a manual or electrical remote control in test fields
or for the automation of test procedures in the field of quality
assurance
Application examples:
Endurance tests with hydraulic drives
Control of hydraulic drives to determine the
physical parameters in connection with quality assurance

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

SYHCE

1/8

RE 57 901/11.02

04

564

Ordering details

SYHCE1 2X
Hydrocontrol electronics

Serial number
Is order related and is
determined in the factory

Series 20 to 29
= 2X
(20 to 2 9: unchanged
installation and connection dimensions)
Housing type
Desk top housing 84TE, one axis
Desk top housing 84TE, one axis,
24V power supply
Desk top housing 84TE, one axis,
24V power supply, VT2000 (ZSB)
Rack 84TE,
one axis
Rack 84TE,
one axis, 24V power supply
Rack 84TE,
one axis, 24V power supply,
VT2000
Rack 84TE,
two axes
Module slot 1A EASP
Free
EASP without front operating facility
EASP with front operating facility
Module slot 2A VR4D
Free
VR4D fitted (CAN)
VR4D fitted (Profibus DP)
VR4D fitted (INTERBUS S)

Module slot 6B (only variant B4!)


Socket card
M0 =
Free
M1 =
BK1
M2 =
BK2 (with antialising filter)

= T1
= T2

Module slot 5B (only variant B4!)DMS


T0 =
Free
T1 =
Fitted with ME10
T6 =
Fitted with ME50S6
(T5 fitted with ME50)
T8 =
Fitted with TF6208
(T7 fitted with TF6207)

= T3
= B1
= B2

Module slot 4B (only varient B4!) LVDT


Free (T1 fitted with ME10)
Fitted with ME50
(T6 fitted with ME50S6)
T7 =
Fitted with TF6207
(T8 fitted with TF6208)
T0 =
T5 =

= B3
= B4
= E0
= E1
= E2

S0 =
S1 =
S2 =
S8 =

= V0
= V1
= V2
= V3

Module slot 3A servo amplifier


Free
Servo amplifier SR91
Servo amplifier SR92
Servo amplifier SR98

V0 =
V1 =
V2 =
V3 =

= S0
= S1
= S2
= S8

Module slot 4A LVDT (DMS)


Free
(T1 fitted with ME10)
Fitted with ME50
(T6 fitted with ME50S6)
Fitted with TF6207
(T8 fitted withTF6208)
Module slot 5A DMS (LVDT)
Free
Fitted with ME10
(T5 fitted with ME50)
Fitted with ME50S6 (T7 fitted with TF6207)
Fitted with TF6208

E0 =
E1 =
E2 =

= T0
= T5
= T7
= T0
= T1
= T6
= T8

Accessories: Cable set see RE 57 900-01-Z


(separate order)
Z8-plug switching amplifier
Type VT-SSV-1-1X/ ... (see RE 30 150)
Operating instructions RE 57 901-B

M0 =
M1 =
M2 =

Moldule slot 3B
(only varient B4!) Servo amplifier
Free
Servo amplifier SR91
Servo amplifier SR92
Servo amplifier SR98
Module slot 2B (only varient B4!) VR4D
Free
VR4D fitted (CAN)
VR4D fitted (Profibus DP)
VR4D fitted (INTERBUS S)
Module slot 1B (only varient B4!) EASP
Free
EASP without front operating facility
EASP with front operating facility
Module slot 6A socket card
Free
BK1
BK2 (with antialiasing filter)

Note: (cursive) = optionally possible

The communication programme is contained


within the VRD controller card scope of supply
RE 57 901/11.02

2/8

SYHCE

565

Technical data (for applications outside these parameters, please consult us)
Dimensions:
Desk top housing
19 rack

(B x H x D )
(B x H x D )

Operating voltage
Power consumption
Processor
Memory
Analogue inputs
Input voltage
Input resistance
Resolution
Non-linearity
Calibration tolerance
Analogue voltage outputs
Output voltage
Output current
Load

448.6 x 132.5 x 262 mm, without front mounted handles and feet
482.6 x 132.5 x 262 mm, without front mounted handles and feet
18 - 36 VDC
12W (in addition the power required for attached sensors/actuators
16/32 Bit MC68376
IFlash-EPROM 1 MB; EEPROM 8KB; RAM 256 KB
3
Max. +/- 15V (+/-10V measurable)
200 KOhm +/-2%
5mV
< 10mV
Max. 40mV (can be individually calibrated on the system)
2
+/- 10V
+/- 10mA
Min. 1 KOhm

Analogue current outputs


Servo amplifier
SR-92
SR-93
SR-98
Carrier frequency measurement amplifier
Potentiometer transducer
Reference voltage
Sensing input
Standard

Serial interfaces

Optional
Digital inputs for operating mode control
Logic level
Digital outputs for operating mode control feedback
Logic level

1
+/- 60mA (further technical data can be found in the relevant data sheets)
+/- 40mA (further technical data can be found in the relevant data sheets)
+/-100mA (further technical data can be found in the relevant data sheets)
2 (further technical data can be found in the relevant data sheets)
1
+/- 10V; +/- 25mV; +/-20mA
+/- 10V or +/- 20mA (adjustable via BK-2)
RS232 (9,6Kbaud)
CANopen
Profibus DP (max. 12Mbaud)
INTERBUS-S
8
log 0 (low) <=5V; log1 (high) >= 10V to UBRe = 3KOhm
8
log 0 (low) <=2V; log1 (high) <= UB Imax 50mA

Digital outputs for valve control


Sequence system
Sandwich plate valve
Logic level

2 (valve control via plug switching amplifier VT-SSV)


2 (valve control via plug switching amplifier VT-SSV)
log 0 (low) <=2V; log1 (high) <= UB Imax 50mA

Digital position transducer


Incremental transducer with TTL-output
Input voltage
Input current

Digital position transducer

Max. frequency relating to Ua1


SSI-transducer
Coding
Data width

Line reciever (TTL)


Input voltage
Input current
Line driver
Output voltage
Voltage supply for the digital position transducer via the HCE
SYHCE

2 (1+1 for the FBOX)


log 0 0 to 1V
log 1 2.8 to 5.5V
log 0 to 0.8mA (to 0V)
log 1 0.8mA (to 5V)
250KHz
1
Grey code
Adjustable up to a max. of 28 bit

log 0
log 1
log 0
log 1

0 to 1V
2.8 to 5.5V
To 0.8mA (to 0V)
0.8mA (to 5V)

log 0
log 1

0 to 0.5V (to 120 Ohm)


2.5 to 5.5V (to 120 Ohm)
UB or +5 VDC; +/- 5%; max. 200mA

3/8

04

RE 57 901/11.02

566

Technical data (for applications outside these parameters, please consult us)
Permissible operating temperature range
Storage temperature range
Weight

0 to 50C
-20 to +70C
4.9 Kg
6.3 Kg
EN 60068-2 / IEC 68-2

One axis
Two axes
To

Enviornmental compatibility
EMC

To
To

EN 61000-6-2 / VDE 0839 part 6 - 7


EN 50081-1 / VDE0839 part 81-1
Further details on request or see RE 09 400-U

HCE-1 modules
The basic version of the hydrocontrol electronics is built into a 19/3HE rack with a rear panel board, into which, depending on the functions
required, the required function modules are fitted. The rear panel board provides all of the required electrical inter-connections to the
electronic modules and plugs. It has to be suppled with an external 24V DC supply.
Module slot 1A/B
Module slot 2A/B
Module slot 3A/B

Voltage stabilsation
EASP
and control panel for the operating modes
Digital control card
VR4D
Servo valve amplifier
Alternatively

SR91
SR92

Alternatively

SR98

Module slot 4A/B

Carrier frequency measuring amplifier TF6207


Alternatively
ME50

Module slot 5A/B

Carrier frequency measuring amplifier TF6208


ME10
ME50S6
Measuring socket card
BK1
Alternatively
BK2

Module slot 6A/B

Controller for closed loop force and position control with integrated
set-up functions and closed loop amplitude control which can be cut-in
For servo alves with electrical feedback
RE 57 850
For servo valves with mechanical feedback
RE 57 851
Maximum control current: 60 mA
For servo valves with mechanical feedback
RE 57 852
Maximum control current: 100 mA
For inductive position transducers
RE 57 721
For DMS force transducers

RE 57 722

With measurement sockets for the command and actual valves


As with BK1, but with additional anti-aliasing filters

RE 57 725
RE 57 726

Unit dimensions (dimensions in mm)

4,4

10

15

20

25

30

35

40

45

50

84 TE x 5,08 = 426,7
449
465,1

55

60

65

70

75

132,5 (3HE 0,85)

57,15
120,6

19 - Rack

80

Card nominal depth: 220 mm


Total depth: 235.4 mm
(plus 46 mm for the
front mounted handles)

482,6

Dimensions for a desk top version: 448.6 x 132.5 x 245 mm (B x H x D) (without plug-in connectors, operating elements, feet, etc. ...)

RE 57 901/11.02

4/8

SYHCE

567

Functions and handling the SYHCE 2X


The HCE is used to closed loop control and monitor hydraulic axes
with valve controls in testing applications.
In addition, coupling of the axis to a pressurised oil supply can be
controlled by the HCE via a esquencing module.
The operation of the most important operating modes is via a key
pad. More extensive operation and parameterisation is possible by
connecting a notebook via a RS 232 interface or field bus connection.
Integration into automation is possible via a DLL, field bus connection
or alternatively via AD/DA or I/O. Suitable drivers for connecting to
Software Tools such as LabView or CAESAR -LAB are available.
Controllers for force and position make it possible to optimal closed
loop control the drive. The command value is overlaid or removed by
an overlay ramp. An amplitude controller is used to provide
compensation for Bode diagram influences.
A simple function generator makes it possible to provide internal
command values. Integrated into the HCE are simple monitoring
functions such as limiting force values with closed loop position
control, limiting position values with closed loop force control.
These functions can be menu controlled via a PC or via call-ups that
are contained within a PC programme.
There is a set-up controller provided for assembly, adjustment and
maintenance tasks (set-up operation). In the set-up mode the axis
can be controlled by a remote control box.
Position values can be processed from the LVDTs by means of carrier
frequency amplifiers, incremental position transducers, digital position
transducers with SSI interfaces or potentiometers.
An integrated carrier frequency amplifier is provided for processing
force signals.
The actual position and force values can also be processed in the
form of 10V. The measured values are made available to the front
mounted BNC-sockets in an analogue form.
All high response valves that are fitted with integrated electronics or
valves that can be controlled by the Rexroth SR9X series of amplifiers
can be controlled.

The HCE unit is configured using a PC. The WIN-PED programme is


available to enable access to all of the functions via a RS232-interface.
It makes it possible to influence all of the parameters, especially during
commissioning and service.

Screenshot WIN-PED
The PC programme HCE-Lab makes it possible to access the controller
parameters via line sliding regulators, so that parameter changes
can be easily carried out during operation.

Screenshot HCE-Lab

Key pad
SYHCE

Here the connection with the PC can be via a RS232 serial interface or
field bus (CANopen, Profibus DP or INTERBUS-S). Further information
regarding the field bus connections are available on request.
A DLL makes it possible to interconnect the HCE into standard programmes
such as LabView, CAESAR -LAB or your own applications. It is thereby
possible to directly access all of the parameters of the closed loop axis. It
is therefore, possible to connect to all of the common automation systems.
Process values, for example command and actual values, can only be
transmitted within the frame work of the band widths that are provided
by the selected field bus connection.
If a field bus is not available then the process values can be transmitted
via an anlogue connection. Operating modes can be selected via an I/O.
A monitoring input can be activated for monitoring the command
computer.
If a field bus is not available then the process values can be transmitted
via an anlogue connection.
A monitoring input can be activated for monitoring the command
computer. If the signal being applied is withdrawn (fails), then the
command value and controllers are switched off, as well as by using the
appropriate circuitry the drive is also depressurised.

5/8

RE 57 901/11.02

04

568

HCE interfaces (external components and connection facilities)


Servo-cylinder axis with:
X9 Inductive position transducer in half
or full bridge circuit,
LVDT (inductive position transducer)

X3 Digital absolute position transducer


with SSI interface or digital
incremental position transducer,

Digital incremental position transducer


Digital absolute position transducer (SSI)

X9 Potentiometer or analogue actual


position value signal ( 10 V)

Potentiometer (analogue actual position


value)

X17 DMS - force transducer in half or


full bridge circuit

Acutal force value (DMS)

X13 Exteral analogue actual force values


( 10 V)

A
a

X2 Control of servo valves


without integrated electronics
via servo amplifier

Servo valve with electrical feedback

Servo valve with integrated electronics


and SI valve

Sequencing module
NS 25
Version "E"

ZSE +
X18 X21
Connection of a sequencing module
with 24V switching valves
(power output stage in Z8 plug)
additional solenoid valve for shutdown function

RE 57 901/11.02

a, b

a, b

Servo valve with mechanical feedback

B
0

a, b

X2 Control and voltage supply ( 15 V)


for servo and high-response control
valves with integrated electronics

Analogue actual force value ( 10 V)

6/8

SYHCE

569

HCE interface (external components and connection possibilities)

X4, X5,
X7, X8

Field bus
Feldbus

RS 232
ADC
DAC
I/O

Remote control and integration via


field busses (CANopen, INTERBUS-S,
Profibus) within the application
programme e.g. LabView, CAESAR LAB etc.

X4

Connection to a PC via a
RS232-interface for the remote control
or parameterising of the HCE

X1

Analogue and digital in/outputs


for control via a PLC or IPC

X6

F-Box
For remotely controlling the drive in the
set-up operating mode

X13
X14

External actual value input


External command value input

X15, X16 In and output for synchronisation


of the carrier frequency measurement
amplifiers (TF)
15 =
TF synchronisation input
16 =
TF synchronisation output
O

SYHCE

7/8

Output signals via the front


BNC-socket for the command
and actual values on the socket card

RE 57 901/11.02

04

570

Notes

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
eMail: info@boschrexroth.co.uk

RE 57 901/11.02

8/8

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application
can be derived from our information.
The details stated do not release you from the
responsibility for carrying out your own
assessment and verification. It must be
remembered that our products are subject to a
natural process of wear and ageing.

SYHCE

571

RE 30 133/02.03
Replaces: 09.02

Controlled system simulator for the


VT-HNC100-1-2X digital axis control
Type VT-HNC100DEMO

HAD 6634/00

Series 2X

Type VT-HNC100DEMO

Table of contents
Contents
Features
Ordering code
Functional description
Technical data
Block circuit diagram
View of the front panel

Features
Page
1
2
2
3
3
4

Suitable for getting familiar with the functions of the


VT-HNC100-1 digital axis control
(in conjunction with the associated PC software WIN-PED)
Simulation (PT2) of a hydraulic controlled system with changeover between high (30 Hz) and low (10 Hz) natural frequency
Visualised rotary movement of the axis (10 LEDs) with acoustic
backing (loudspeakers)
8 switches for digital PLC inputs
8 LEDs for digital PLC outputs
3 position feedbacks can be selected: incremental
SSI
analogue
Power supply unit for 100 to 240 VAC (including adapter for US
power supply)

04

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

VT-HNC100DEMO

1/4

RE 30 133/09.02

572

Ordering code

VT-HNC100DEMO 2X /

Basic equipment
Demo case,
VT-HNC100Simulator-1-2X
with power supply unit (Euro-plug) 100 to 240 V 24 V/1.25 A
(with adapter for US power supply)
and connecting cable V24 from the PC to the HNC100

*
Further details in clear text
PC program WIN-PED on CD-ROM:
1=

Series 20 to 29
(20 to 29: unchanged technical data and pin assignment)

= 2X

0=
1=
P=
C=
I=

With SYS-HNC-WINPED-C01
HNC100 equipment:
Without HNC100
With HNC100 Standard W-08-0-0
With HNC100 Profibus W-08-P-0
With HNC100 CANopen W-08-C-0
With HNC100 INTERBUS-S W-08-I-0

Functional description
The controlled system simulator represents the basic device of the
VT-HNC100DEMO demo case. In the basic version, the demo case
comprises, apart from the controlled system simulator, a power supply unit for supplying the VT-HNC100 controller assembly, which, in
turn, supplies the controlled system simulator with the required operating voltage via the encoder cable.
In addition, the basic equipment includes a connecting cable for the
V24 interface between the PC and the HNC100.
Moreover, the demo case offers space for an HNC100 as well as the
PC program WIN-PED (CD-ROM version). Both can be ordered as
optional extra.
The controlled system simulator is provided with a ribbon cable for
connecting it with the VT-HNC100:
X3 encoder for incremental or SSI encoder and supply voltage
+ 5 V and + 24 V
X2 analogue IN/OUT for analogue position feedback and
controlling of the simulation axis
X1 for 8 digital PLC inputs and outputs
X6 connection of the power supply unit (included in the scope
of supply) with the HNC100
After the HNC100 was parameterised with the help of the PC program WIN-PED, the controlled system simulator is controlled on
the basis of the system deviation from the HNC100 at 10 V via Uout 1.
An analogue second-order delay element, which can be changed
over with regard to natural frequency, simulates the controlled hydraulic cylinder or motor system. Switching position 30 Hz simulates systems, in which only the P-controller can be used, whereas at
switching position 10 Hz it is possible to simulate closed-loop state
controls with acceleration feedback. After the second-order time delay, the signal is again made available to the HNC100 in two forms,
directly as analogue position signal and proportionally converted into
a frequency. In the first case, the control loop is closed with the analogue position signal of 0 to +10 V. In the second case, the resulting
frequency is used for generating an SSI or incremental signal sequence for digital position measuring systems.

RE 30 133/02.03

The resolution of these position signals can be freely selected in the


HNC100. The frequency for the digital position signals is also used
for controlling the running light consisting of 10 LEDs. This visualisation of the movement is backed by an acoustic signal from a loudspeaker. The volume of the operating noise can be adjusted by means
of a potentiometer.
The type of position encoder for the closed control loop is selected
exclusively in the HNC100 or with the PC program WIN-PED, menu
item Machine data/Encoders.
8 sliding switches with check lamps are provided for simulating the
PLC inputs. The outputs of the HNC100 to the PLC are signalled by 8
LEDs. A DC/DC converter generates from the +24 V supply voltage
the required voltage of 15 V for the analogue components.
Demo program
When the demo case is despatched together with an HNC100, a
demo program (DEMO_INK_PR) is installed on this HNC100 so
that the controlled system simulator can simulate an axis with incremental encoder.
You can start the demo program by actuating the sliding switches on
the front panel (PLC Inputs) in the following order:
1. Input 2 to on
2. Input 1 to on
3. Input 5 to on
For further information, please refer to the comments of the NC program.
If you order the demo case without the PC program WIN-PED, the
demo program DEMO_INK_PR is provided on a floppy disk.
If you order the PC program WIN-PED, this demo program as well
as two further demo programs (simulation axis with absolute encoder DEMO_ABS_PR and with analogue encoder
DEMO_ANA_PR) are provided on the program CD.

2/4

VT-HNC100DEMO

573

Technical data (for applications outside these parameters, please consult us!)
Power supply unit
Operating voltage

Current consumption

Output voltages

Cable length to the VT-HNC100

Dimensions (W x H x D)

100 to 240 VAC; 47 to 63 Hz


700 mA
+ 24 VDC; 1.25 A
2m
65 x 35 x 130 mm

Weight

0.3 kg

0.4 m

Controlled system simulator


Length of ribbon cables to the VT-HNC100
Dimensions (W x H x D)

190 x 50 x 140 mm

Weight

0.3 kg

Conneting cable from the PC to the VT-HNC100


Length

3m

Block circuit diagram


HNC
outputs

HNC
inputs

V
Uout 1

30 Hz
10 Hz
Natural frequency, can be
changed over
+5V

Power

Running light

SSI
generator
X1

SSI

INK
generator

Ua 0; /Ua 0
Ua 1; /Ua 1
Ua 2; /Ua 2
Uin 2

+ 24 V
Uin 1

04
8 PLCs

8 PLCs

PLC outputs

PLC inputs
(sliding switches
with check lamps)

Range of values X1: 0 to 32 767

VT-HNC100DEMO

3/4

RE 30 133/09.02

574

View of the front panel

1
2
3
4
5
6
7

P
L
C
O
u
t
p
u
t
s

HNC100
PLC
Inputs
Closed Loop
Simulator
5

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
eMail: info@boschrexroth.co.uk

RE 30 133/09.02

4/4

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application
can be derived from our information.
The details stated do not release you from the
responsibility for carrying out your own
assessment and verification. It must be
remembered that our products are subject to a
natural process of wear and ageing.

VT-HNC100CEMO

575

RE 29690/08.05
Replaces: 09.00

Test and demonstration unit


for digital electronic cards

1/4

Typ VT-DVT-1

Series 1X

H5864_d

Table of contents
Contents

Features
Page

Features

Ordering code

Technical data

Pin allocation

Suitable for controlling and functional tests of digital amplifier


and accessory cards
The unit allows the pre-configuration of these electronic cards
and first commissioning on site
At the time of publication of this data sheet, the following
electronic cards can be tested:
VT-VSPD-1-1X/V0/0
VT 12340-1X
VT-VRPD-1-1X/V0/0
VT 12350-3X
VT-VRPD-2-1X/V0/0
VT 12352-3X
VT-VAD-2-1X/V0/0
VT-SWKD-1-1X/V0/0
VT-SWKD-2-1X/V0/0

04

576
2/4

Bosch Rexroth AG

Hydraulics

VT-DVT-1

RE 29690/08.05

Ordering code
VT-DVT-1

1X

Test and demonstration unit for digital electronic cards; with


power supply cable and 16-pin terminal connector

Further details in clear text

Series 10 to 19
(10 to 19: unchanged technical data and pin allocation)

=6

Operating voltage
230 VAC
120 VAC

01 =
02 =

Technical data (For applications outside these parameters, plesae consult us!)

VT-DVT-1-1X/01

VT-DVT-1-1X/02

Operating voltage

UB

210 to 240 VAC

110 to 120 VAC

Power consumption

Imax

1.5 A

1.5 A

IS

Fuse
Dimensions (W x H x D):
Weight

1.6 A T

1.6 A T

without handle

260 x 155 x 330 mm

260 x 155 x 330 mm

with handle

310 x 155 x 410 mm

310 x 155 x 410 mm

4.6 kg

4.6 kg

577
RE 29690/08.05

Hydraulics Bosch Rexroth AG

VT-DVT-1

3/4

Pin allocation
View to front panel

d2

d4

d6

d8

d10
0

power
24 V

d18

d12

d30

d32

z32

z32

b2

b6

b10

b14

b18

b22

b32

b4

b8

b12

b16

b20

b24

d20

100%

P1

+100%

10 V

GND

100%

10 V

Certain signals of the digital electronic card are made available at


the front panel for further processing. Depending on the card
that is plugged in, not all of the contacts are assigned.
Analog inputs (b2 to b24) are available via 4 mm plug-in contacts. Two command value potentiometers with a voltage range
of 10 V are vailable for stimulating the analog inputs.

P2

+100%

GND

DVT

Additional 4 mm plug-in contacts are available for two analog


outputs (d30 and d32).
The digital inputs (d2 to d12 and d18) can be controlled via
tumbler switches.
The status of the two possible digital outputs (b32 and d20) is
signalled by two LEDs (yellow).

Connector at the rear

Z2
Z4
Z6
Z8
Z10
Z12
Z14
Z16
Z18
Z20
Z22
Z24
Z26
Z28
out Z30
out Z32

A connector is located at the rear of the unit, to


which solenoids (z2 to z8) and position transducers (z10 to z28) can be connected and a
voltage supply of 24 V (z30 against z32) made
available.
The maximum power drawing is 5 A minus the
power consumption of the electronic card.

04

578
4/4

Bosch Rexroth AG

Hydraulics

VT-DVT-1

RE 29690/08.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

579
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 067/11.02

00103602

Test adapter (11P+PE) for OBE


VT-PA-1

Type VT-PA-1

List of contents

Features

Contents
Features
Ordering data
Preferred types
Function

Page
1
1
1
2

The test adapter is employed for testing communication


signals between the system controller and the valve (supply
voltage, setpoint, feedback value).
The presence of the supply voltage is also indicated by the
LED.
The enable signal (PIN 3) can be deactivated by means of
a switch.

Caution
Never feed external voltage into the test jacks!
Only connect valves with identical pin assignment.

Ordering data

Preferred types (available at short notice)


VT-

Test adapter (11P+PE) for OBE

PA-

Material no.
0 811 405 118

Type VT-PA-1
VT-PA-1

04

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-PA-1

1/2

RE 30 067/11.02

580

Function

System
controller

Valve

WxHxD

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 067/11.02

(160 x 100 x 65) mm

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

2/2

VT-PA-1

581
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 068/11.02

Test adapter (6P+PE) for OBE


VT-PA-2

Type VT-PA-2

List of contents

Features

Contents
Features
Ordering data
Preferred types
Function

Page
1
1
1
2

The test adapter is employed for testing communication


signals between the system controller and the valve (supply
voltage, setpoint, feedback value).
The presence of the supply voltage is also indicated by the
LED.

Caution
Never feed external voltage into the test jacks!
Only connect valves with identical pin assignment.

Ordering data

Preferred types (available at short notice)


VT-

Test adapter (6P+PE) for OBE

PA-

Material no.
0 811 405 163

Type VT-PA-2
VT-PA-2

04

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-PA-2

1/2

RE 30 068/11.02

582

Function

System
controller

Valve

Supply voltage

Ground

WxHxD

(110 x 65 x 70) mm

D, E Ground
F, C Feedback signal

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 068/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

2/2

VT-PA-2

583
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 070/11.02

Test adapter for electric amplifiers


Type VT-PA-3

Type VT-PA-3

List of contents

Features

Contents
Features
Ordering data
Preferred types
Application
Device dimensions

Page
1
1
1
2
2

For checking existing


electrical system
For measuring and checking
loads

Ordering data
VT-

PA-

Test adapter for


electric amplifiers

Preferred types (available at short notice)


Material no.
0 811 405 114

04

Type VT-PA-3
VT-PA-3

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-PA-3

1/2

RE 30 070/11.02

584

Application
For Europe cards
(100 x 160) mm with plug to
DIN 41 612, type F32.
Measurement taps 4 mm for all
conductors b and z, 2 ... 32.
All conductors suitable for solenoid current and voltage
supply.

Caution

Never feed external voltage into the


measurement taps!

Device dimensions (in mm)

Eurocard

Catch

32 Measurement
taps

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 070/11.02

The
contained
hereinallein
is intended
Die information
angegebenen
Daten dienen
der
to
serve purely as a product
description.
inProduktbeschreibung.
Eine Aussage
berThe
eine
formation
have providedoder
cannot
used asfr
bestimmtewe
Beschaffenheit
einebe
Eignung
evidence
of a particular
aspect orkann
of suitability
einen bestimmten
Einsatzzweck
aus
for
a particular
purpose.
Please notewerden.
that ourEs ist
unseren
Angaben
nicht abgeleitet
products
are subject
to theProdukte
natural processes
zu beachten,
dass unsere
einem of
ageing
and wear.
natrlichen
Verschlei- und Alterungsprozess
unterliegen.

2/2

VT-PA-3

585

Current-measuring test adapter

RE 30073/01.05
Ersetzt: 09.03

1/4

Type VT-PA-5

Overview of contents
Contents

Features
Page

Features

Ordering data

Preferred types

Applications

Test assembly

Proportional plug amplifier

External valve amplifier

Measurement of solenoid current in valves

04

586
2/4

Bosch Rexroth AG

Industrial Hydraulics

Ordering data

Type VT-PA-5

RE 30073/01.05

Preferred types (available at short notice)

VTPA 5

Type

Material No.

VT-PA-5

0 811 405 173

Current-measuring test adapter

Applications
The test adapter is employed for measuring the solenoid current
in valves.
This measurement provides an indication of the valves modulation status, particularly in the case of proportional valves without
position control.

The proportional plug amplifier can be plugged directly into the


adapter.
Valves that are actuated by a PCB-type amplifier can also
be tested.
To connect the measuring device, first remove the jumper plug.

Example characteristic curve

Max. modulation

Closed-circuit current range

587
RE 30073/01.05

Type VT-PA-5

Industrial Hydraulics

Bosch Rexroth AG

3/4

Test assembly

Proportional plug amplifier

Plug amplifier

Test specimen

External valve amplifier

04

Test specimen

588
4/4

Bosch Rexroth AG

Industrial Hydraulics

Type VT-PA-5

RE 30073/01.05

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
D-97816 Lohr am Main, Germany
Telefon

+49 (0) 93 52 / 18-0

Telefax

+49 (0) 93 52 / 18-23 58

documentation@boschrexroth.de
www.boschrexroth.de

Bosch Rexroth AG reserves all rights, including industrial property rights.


We reserve all rights of disposal, such as copying and passing on to third
parties.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of own judgement and verification. It must be remembered
that our products are subject to a natural process of wear and aging.

589
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 063/11.02

Test box I
VT-PE-TB1

Typ VT-PE-TB1

List of contents

Features

Contents
Features
Ordering data
Preferred types
Application
Additional information
Testing and service accessories
Possible tests
Technical data

Page
1
1
1
2
2
2
2
3

For all single-stage proportional valves without on-board


electronics
For commissioning into service and monitoring the operation
of valves and associated electronics
Setpoints can be set as default either internally or externally
Measurement taps for inputs and outputs
Power supply 115/230 V AC
Connecting cable supplied

Ordering data
VT-

PE-

TB1

Test box I

Preferred types (available at short notice)


Material no.
0 811 405 166

04

Type VT-PE-TB1
VT-PE-TB1

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-PE-TB1

1/4

RE 30 063/11.02

590

Application
Test box I is used for commissioning into service and monitoring
the operation of single-stage proportional valves with and
without position control, and their external valve amplifiers in
Europe format. The unit is provided with all the necessary signal

and voltage connections, inputs and outputs, as well as


measurement taps and a multimeter.
This enables a test programme to be designed which operates
independently of the machines control system.

Additional information

Testing and service accessories

Supplied with the test box are a power cord, a position transducer cable and two solenoid cables.
The unit can be connected to either 115 V or 230 V mains power
supply.
A full description can be found in 1 819 929 110.

For commissioning into service and testing existing electrical


systems and for measuring and checking loads, we recommend
the test adapter for printed circuit boards VT-PA-3. For product
information and technical data, please see RE 30 070.

Possible tests
The following valves can be tested:

Pressure, throttle and flow control


valves without position control
(one- and two-channel versions)

Directional control valves


without position control

Pressure, throttle, flow control and directional


control valves with position control

RE 30 063/11.02

2/4

VT-PE-TB1

591

Technical data (For device applications beyond the stated values, please consult us!)
General
Dimensions
Weight
Mains voltage

Fuse
Current rating
Ambient temperature
Degree of protection
CE test

(305 x 215 x 195) mm


7.6 kg
115 V 10 %
230 V 10 %
Adjust to mains voltage by turning the fuse 180
630 mA slow blowing (at 115 V)
315 mA slow blowing (at 230 V)
Max. 0.4 A (with NG 10 valve) at 115 V
Max. 0.2 A (with NG 10 valve) at 230 V
0 ... +50 C
IP 40
EN 50 081-1
EN 50 082-2
EN 60 742

04

VT-PE-TB1

3/4

RE 30 063/11.02

592

Notes

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 063/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

4/4

VT-PE-TB1

593
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 064/11.02

Test box II
VT-PE-TB2

Type VT-PE-TB2

List of contents

Features

Contents
Features
Ordering data 1
Preferred types
Application
Additional information
Testing and service accessories
Possible tests
Technical data

Page
1
1
2
2
2
2 and 3
4

For pilot operated proportional valves and servo solenoid


valves with external amplifier
For commissioning into service and monitoring the operation
of valves and associated electronics
Setpoints can be set as default either internally or externally
Measurement taps for inputs and outputs
Power supply 115/230 V AC
Connecting cable supplied

Ordering data
VT-

PE-

TB2

Test box II

Preferred types (available at short notice)


Material no.
0 811 405 167

04

Type VT-PE-TB2
VT-PE-TB2

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-PE-TB2

1/4

RE 30 064/11.02

594

Application
Test box II is used for commissioning into service and monitoring
the operation of:
Pilot operated proportional valves
Servo solenoid valves
Pressure control loops
and their external valve amplifiers.

The unit is provided with all the necessary signal and voltage
connections, inputs and outputs, as well as measurement taps
and a multimeter.
This enables a test programme to be designed which operates
independently of the machines control system.

Additional information

Testing and service accessories

Supplied with the test box are a power cord, two position
transducer cables, three pressure sensor cables and two solenoid
cables.
The unit can be connected to either 115 V or 230 V mains power
supply.
A full description can be found in 1 819 929 109.

For commissioning into service and testing existing electrical


systems and for measuring and checking loads, we recommend
the test adapter for printed circuit boards VT-PA-3. For product
information and technical data, please see RE 30 070.

Possible tests
1. Testing pilot operated proportional valves
With this type of valve, the flow rate setpoint can be set
as default, the ramp function controlled and the feedback
values of the pilot and main stages displayed.

RE 30 064/11.02

2/4

VT-PE-TB2

595

Possible tests
2. Testing pressure control loops
Using this test box, pressure control loops comprising servo
solenoid valve, pressure sensor and p/Q controller card can
also be monitored and adjusted.
Pressure sensors with voltage and current signals can be
connected to the test box. The correct cables for the different
plug versions are supplied.

The setpoints for the pressure p and the flow rate Q can be set
as default.
The feedback values of the pressure p and the valve position
transducer(s) are displayed.

3. Testing servo solenoid valves


Both directly operated and pilot operated servo solenoid
valves can be monitored or actuated.
The valve setpoint can be set as default and the feedback
value(s) displayed.

2
2

VT-PE-TB2

3/4

04

RE 30 064/11.02

596

Technical data (For device applications beyond the stated values, please consult us!)
General
Dimensions
Weight
Mains voltage

Fuse
Current rating
Test data

Ambient temperature
Degree of protection
CE test

(305 x 215 x 195) mm


7.6 kg
115 V 10 %
230 V 10 %
Adjust to mains voltage by turning the fuse 180
630 mA slow blowing (at 115 V)
315 mA slow blowing (at 230 V)
max. 0.4 A (with NG 10 valve) at 115 V
max. 0.2 A (with NG 10 valve) at 230 V
Setpoint signal Q
Setpoint signal p
Pilot valve feedback signal
Main stage feedback signal
Solenoid current
Pressure sensor feedback signal
0 ... +50 C
IP 40
EN 50 081-1
EN 50 082-2
EN 60 742

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 064/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

4/4

VT-PE-TB2

597
Industrial
Hydraulics

Electric Drives
and Controls

Linear Motion and


Assembly Technologies

Service
Automation

Pneumatics

Mobile
Hydraulics

RE 30 065/11.02

00102454

Test box III


VT-PE-TB3

Type VT-PE-TB3

List of contents

Features

Contents
Features
Ordering data
Preferred types
Application
Additional information
Testing and service accessories
Possible tests
Technical data

Page
1
1
1
2
2
2
2
3

For all valves with on-board electronics and voltage interface


For commissioning into service and monitoring the operation
of valves and associated electronics
Setpoints can be set as default either internally or externally
Measurement taps for inputs and outputs
Power supply 115/230 V AC
Connecting cable supplied

Ordering data
VT-

PE-

TB3

Test box III

Preferred types (available at short notice)


Material no.
0 811 405 168

04

Type VT-PE-TB3
VT-PE-TB3

2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part,
by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages.
This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness.
We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete
or inaccurate information.

VT-PE-TB3

1/4

RE 30 065/11.02

598

Application
Test box III is used for commissioning into service and monitoring the operation of all valves with on-board electronics and
voltage interface. The unit is provided with all the necessary
signal and voltage connections, inputs and outputs and

measurement taps, making it possible to design a test programme which operates independently of the machines control
system.

Additional information

Testing and service accessories

Supplied with the test box are a power cord and two valve
connecting cables (one for 7-pole and one for 12-pole
electronics). The unit can be connected to either 115 V or
230 V mains power supply.
A full description can be found in 1 819 929 113.

For commissioning into service and testing existing electrical


systems and for measuring and checking loads, we recommend
the test adapter for printed circuit boards VT-PA-3. For product
information and technical data, please see RE 30 070.

Possible tests
Test valve function
External setpoint source
Internal setpoint source
Test communication signals between
valve and system controller

Power supply

System connection

Valve connection

Jacks for external


test units

Input jacks for external voltage supply

RE 30 065/11.02

Input jacks for external setpoint source

2/4

VT-PE-TB3

599

Technical data (For device applications beyond the stated values, please consult us!)
General
Dimensions
Weight
Mains voltage

Fuse
Current rating
Ambient temperature
Test box to valve connecting cable
Line connectors
Test data

Display
Degree of protection

(305 x 215 x 195) mm


6.8 kg
115 V 10 %
230 V 10 %
Adjust to mains voltage by turning the fuse 180
0,1 A (at 115 V)
0.5 A (at 230 V)
max. 0.7 A (with valve connected) at 115 V
max. 0.3 A (with valve connected) at 230 V
0 ... +50 C
LIYCY 12 x 0.5 (for connection to 12-pole electronics)
LIYCY 17 x 0.5 (for connection to 7-pole electronics)
06 P + PE-pole Pg 11; 1 834 482 022
11 P + PE-pole Pg 16; 1 834 482 142
Valve feedback signal
Valve setpoint
Valve supply voltage
LCD 31/2-digit, all test data, LEDs
IP 40

04

VT-PE-TB3

3/4

RE 30 065/11.02

600

Notes

Bosch Rexroth AG
Industrial Hydraulics
D-97813 Lohr am Main
Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52/18-0
Telefax 0 93 52/18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

RE 30 065/11.02

The information contained herein is intended


to serve purely as a product description.
The information we have provided
cannot be used as evidence of a particular
aspect or of suitability for a particular purpose.
Please note that our products are subject
to the natural processes of ageing and wear.

4/4

VT-PE-TB3

601

Service case with test unit for proportional valves and their control
electronics

RE 29687/06.05
Replaces: 01.03

1/8

Type VT-PPV-1

Series 1X

H/A/D 6732/00

Table of contents
Contents

Features
Page

The service case comes with an integrated test unit, various


cable sets and accessories

Features

Ordering code

Unit drawing

Description of operators panels:


Operators panel 1
Operators panel 2
Operators panel 3

3
4
5

Checking call-up functions

Block circuit diagram

Checking of solenoid currents

Technical data

Measurement of external DC voltages up to 100 V

Overview of proportional valves that can be tested

Switching and testing of relays and analogue switches on


electronic cards

Test unit for commissioning and servicing proportional valves


and their analogue and digital control electronics
Manual preselection and adjustment of command values
Measurement and adjustment of ramp times
Checking of command value and actual value voltages

LED indicator lamps for 24 V outputs


Functional testing of amplifiers of modular design
Functional testing of valves with integral electronics possible
by means of a separate cable (not included in the scope of
supply). This test case can also be used to subject valves of
competitors to functional tests.
A connecting cable with open ends is included.
Further information:
For a product description and operating instructions for
VT-PPV-1, see RE 29687-B

Service case:
Dimensions (W x H x D) 530 x 390 x 210 mm
Weight (complete)
ca. 10 kg

04

602
2/8

Bosch Rexroth AG

Hydraulics

RE 29687/06.05

VT-PPV-1

Ordering code
VT-PPV-1

1X V0

Service case with integrated test unit


for proportional valves and their control electronics

*
Further details in clear text

0=

Series 10 to 19
(10 to 19: Unchanged technical data and pin assignment)

= 1X

Basic version

V0 =

Basic version

The scope of supply comprises:


Designation

Material-Number:

General accessories included in the scope of supply

Test unit VT-PPV (in the service case)

Measuring cables (red and black) with laboratory plugs

Cable set for solenoidd; 2-pin (2x)

R900899764

(4 mm to 2 mm)

Cable set for displacement transducer; 3-pin

R900899765

Mains cable

Cable set for displacement transcucer; 4-pin

R900899766

Spare fuses

Cable set for slot 7; 4-pin

R900899767

Screw driver (blade with 2.5 mm)

Cable set for slot 7; 5-pin

R900899768

Not included in the scope of supply:


Cable set VT-PPV Slot 7, 10 mA Adapter

Material-No. R900733785

Further cable sets for testing valves with integral electronings on enquiry.

Unit drawing
Changeover measurung signal

solenoid A

solenoid B

Mains connection and mains switch


with integrated fuse (0.5 A delayed)

Fuse (4 A delayed)
for Ub1-7 (24 V)

Do NOT attempt to connect slot 7 without


confirming that the electronic is correct connected

positional transducer

fuse

Do not plug or connect more than


one electronic card or system value

7
1

2
VT2000
VT2010
VT2013
VT2023
VT-VSPA1

VT5001
- VT5004
VT5010
- VT5018

VT3000

VT5005

VT-SWKA

VT3006

VT5006

VT-VRPA1

VT3013

VT5007

VT-VRPA2

VT5020
- VT5023

VT3014

VT5008

VT-VSPA1

VT3017

VT5024

VT-VSPA2

VT3018

VT5025

VT3024

VT5035

VT5032
- VT5034
VT5036
VT5037

extern
signal value / actual value
solenoid A / B

VT-SWKD
VT-VRPD
VT-VSPD

extern [U] = V
signal value [U] = V
solenoid A [I] = A

P1

power
110V - 230V

fuse

V
max. 100V DC
on
actual value [U] = V
solenoid B [I] = A

VT-VSPA2

VT5062
- VT5066

ramp time
[t] = s

P2

off

P3

VT-VRPA1

VT-PPV-1

VT5011 - 18
VT5062 - 66
VT-VRPA1
VT50xx
0%

slot 1 - 7

100%

+100%

K1 /
w1:

0-6V

4-20mA

0-9V

0-10V

enable:

on
off

K1:

ramp:

on
off

up
down

on
off

FES25
4WRE..-1X
DBETR
2FRE
4WRE..-2X

0 - 100%
0 - +100%
100% - +100%

on
off

t1:

on
off

100%

on
off
A1
A2
A3
on
off

d8:

on
off

d10:

on
off

d12:

on
off

on
off

4Q:

on
off

1:

on
off

t2:

on
off

analog
output:

K3 /
w3:

on
off

ramp:

on
off

enable:

on
off

t3:

on
off

d2:

K4 /
w4:

on
off

t4:

on
off

d4:

on
off

d14:

on
off

(K6):

d6:

on
off

d16:

on
off

+10V

d20

z22

10V

d26

ready

3,4,5

0 - 100%
0 - +100%
100% - +100%

+100%
100%

0%
0%

enable:

4 - 20mA
off
0 - (+/)10V

+100%

K2 /
w2:

ready
1,2

4 - 20mA
0 - (+/)10V
0 - (+/)6V

+100%
100%

0%
0%
0-6V/0-9V
off
0-10V/4-20mA

on
off

+100%

2
1

3 4

fault
5
6

+ 10 V

E1 - E6

10 V
3

6
7
off

2
1

Warning:
6,7

4 5

slot

Do NOT attempt to switch 7 without confirming


that slot 7 and the electronic is correct connected

Operator panel 1

Operator panel 2

Operator panel 3

Rotary switch for

(for slots 1 and 2)

(for slots 3, 4 and 5)

(for slots 6 and 7)

selecting the slot

603
Hydraulics Bosch Rexroth AG

VT-PPV-1

RE 29687/06.05

3/8

Description of operators panel

Operator panel 1:
Slots 1 and 2 are assigned to this operator panel.

Inversion of the displacement


transducer singal

VT5011 - 18
VT5062 - 66
VT-VRPA1

Potentiometer for
command value adjustment

VT50xx

Preselection of the
command value

0%

+100%
d
o
w
n

0-6V/0-9V
off
0-10V/4-20mA
Selection of the command value
(0 to 6 V or 0 to 9 V)

0-6V

4-20mA

0-9V

0-10V

Type of command value


(4 to 20 mA or 0 to 10 V)

Call-up relay K1

enable:

on
off

ramp:

on
off

External enable

External ramp ON/OFF switch

K1:
up

on
off

External ramp ON/OFF switch


(for slot 1 only)
Selection:
Ramp up or down off

ready

1,2

Indicator lamp for output


Ready for operation (24 V)

Indicator lamp
operator panel active

04

LED function indicator lamp (signals, whether the switch for the selected slot is active)

604
RE 29687/06.05

Hydraulics Bosch Rexroth AG

VT-PPV-1

4/8

Description of operators panel (continued)


Operator panel 2:
Slots 3, 4 and 5 are assigned to this operator panel.

External
ramp time
ON/OFF
switch

Potentiometer for
command value
adjustment

100%

Command
value
selection
ON/OFF

Quadrant
operation

on
off

+100%

Type of
command
value

4 - 20mA
0 - (+/)10V
0 - (+/)6V

External
command value inversion

Command
value range

0 - 100%
0 - +100%
100% - +100%

+100%
100%

0%
0%

K1 /
w1:

on
off

K1/w1 to K4/w4:

K2 /
w2:

on
off

4Q:

on
off

1:

Relay call-ups/
command value
call-ups

K3 /
w3:

on
off

ramp:

on
off

enable:

K4 /
w4:

on
off

Relay call-ups (K6)/ (K6):


Inversion of the callup command value
inputs (UP)

t1:

on
off

on
off

t2:

on
off

on
off

t3:

on
off

t4:

on
off

+10V

d20

z22

10V

d26

ready

t1 to t4:
Ramp
call-ups
(24 V)

3,4,5
Indicator lamp
operator panel
active

Indicator lamp for


output d20 (24 V)

Indicator lamp +10 V-output


(LED active:
+9.5 V < U+10 V-output < +10.5 V)

Indicator lamp for


output d26 (24 V)

External
enable

Indicator lamp for


output z22 (24 V)

Indicator lamp for output


ready for operation (24 V)

Indicator lamp -10 V-output


(LED active:
10.5 V < U10 V-output < 9.5 V)

LED function indicator lamp (signals, whether the switch for the selected slot is active)

605
5/8

Bosch Rexroth AG

Hydraulics

VT-PPV-1

RE 29687/06.05

Description of operators panel (continued)

Operator panel 3:
Slots 6 and 7 are assigned to this operator panel.

Potentiometer for
command value
adjustment

Inversion of the
displacement
transducer signal

Type of
comand
value

FES25
4WRE..-1X

External
enable

DBETR
2FRE
4WRE..-2X
enable:

Changeover
of command
value output

d2 to d16:
Digital inputs
(24 V)

100%

Command value
range

0 - 100%
0 - +100%
100% - +100%

+100%
100%

d8:

on
off

analog
output:

A1
A2
A3

d10:

on
off

d2:

on
off

d12:

on
off

d4:

on
off

d14:

on
off

d6:

on
off

d16:

on
off

Indicator lamp
operator panel
active

4 - 20mA
off
0 - (+/)10V

+100%

0%
0%
on
off

Indicator lamp
external
fault output

2
1

3 4

fault
5
6

E1 - E6

+ 10 V
10 V

Indicator lamp switching output 2


(LED active:
10.5 V < U10 V-output < 9.5 V)
Indicator lamp switching output 1
(LED active:
+9.5 V < U+10 V-output < +10.5 V)

6,7
Selection of command value input

04

Ground

230 V

to

110V

Ub5

+ 15 V
+ 10 V
M0
10 V
15 V

1AT

Ub1

DC

DC

0V

24 V

Ub2

DC

AC

Ub1

4AT

Ub2

Ub6
Ub7

Ub3
Ub4
Ub5

selection

Slot

Operator
panel 3

Operator
panel 2

Operator
panel 1

Slot:

32-pin socket connector


32-pin socket connector
32-pin socket connector
48-pin socket connector
64-pin socket connector
4- and 5-pin plug-in connectors

...
...
...
...
...
...

3
4
5
6
7

Ub7
0V
Enable
CommComm+

5-pin
1
2
3
4
5

7*

7*

32-pin socket connector

Slots

Slots

...

A+
A
B+
B

Slots

*Slot 7: 4-pin
1
2
3
4

Ub1 Ub2

1)

Actual value
Solenoid B

External command value


Solenoid A

black

(+shield) 1)

Connection of
displacement
3- or 4-pin

Solenoid B

Solenoid A

... depending on the slected cable set

red

B+
B

A+
A

Ramp time

External voltage
measurement

VT-PPV-1

Ub3
Ub4
Ub5

Ub1
Ub2
Ub3
Ub4
Ub5
Ub6

PE

Mains
switch

RE 29687/06.05

606
Hydraulics Bosch Rexroth AG
6/8

Block circuit diagram

607
RE 29687/06.05

Hydraulics Bosch Rexroth AG

VT-PPV-1

7/8

Technical Data (for applications outside these parameters, please consult us!)
General
Operating voltage

UB 110 VAC to 230 VAC; -15 % + 10 %; 47 Hz to 63 Hz

Power consumption

PS max

Current consumption

approx. 55 VA

Imax approx. 0.5 A

Fuses:
Primary side (110 to 230 V)

IS 1 A delayed

Secondary side (24 V)

IS

4.0 A delayed

Measuring ranges:
External voltage measurement

U 0 to 100 VDC

Ramp time measurement

t 10 ms to 99.99 s

Dimensions (W x H x D)

530 x 390 x 210 mm

Permissible operating temperature range

0 to 50 C

Storage temperature range

25 C to +85 C

Weight

approx. 10 kg

Slots 1 to 7
Ub1 to Ub7 24 V

Supply voltage
Command value preselection

U 0 to +10 V or 10 to +10 V
U 0 to +9 V
U 0 to +6 V or 6 V to +6 V
I 4 to 20 mA

Call-ups

U 24 V

Connections
Mains voltage

Connector plug for non-heating apparatus

Solenoid A:

2-pin plug-in connector (connecting cable included in the scope of supply)

Solenoid B:

2-pin plug-in connector (connecting cable included in the scope of supply)

Displacement
transducer:

5-pin plug-in connector (depending on the selection of the cable set for 4-pin or 3-pin
connection of the displacement transducer)

Slots 1 to 4:

32-pin socket connector (form D)

Slot 5:

48-pin socket connector (form F)

Slot 6:

64-pin socket connector (form G with Millerspalte)

Slot 7:

5-pin plug-in connector and


4-pin plug-in connector for measuring solenoid currents

External voltage
measurement:

4 mm socket

04

608
8/8

Bosch Rexroth AG

Hydraulics

VT-PPV-1

RE 29687/06.05

Overview of control electronics that can be tested


At the time when this data sheet was published, the test unit VT-PPV-1 could be used to carry out functional tests on the following
control electronics:
Slot on the test unit
1

(64-pin socket conn. (4- and 5-pin


(32-pin socket connector) (32-pin socket connector) (32-pin socket connector) (32-pin socket connector) (48-pin socket connector) with Millerspalte) plug-in connectors)
VT 2000

VT 5001

VT 3000

VT 5005

VT-SWKA-1

VT-SWKD

VT 2010

VT 5002

VT 3006

VT 5006

VT-VRPA1

VT-VRPD

VT 2013

VT 5003

VT 3013

VT 5007

VT-VRPA2

VT-VSPD

VT 2023

VT 5004

VT 3014

VT 5008

VT-VSPA1

VT-VSPA1

VT 5010

VT 3017

VT 5024

VT-VSPA2

VT 5011

VT 3018

VT 5025

VT 5012

VT 3024

VT 5035

VT 5013

VT-VSPA2

VT 5014
VT 5015
VT 5016
VT 5017
VT 5018

Amplifiers of
modular design
Controlling of
valves with
integral elektronics possile by
means of seperate
(cable not included in the
scope of
supply).
Connecting cable with open
ends included.

VT 5020
VT 5021
VT 5022
VT 5023
VT 5032
VT 5033
VT 5034
VT 5036
VT 5037
VT 5062
VT 5063
VT 5064
VT 5065
VT 5066
VT-VRPA1
Caution!
No more than one electronic component may be plugged or connected at a time. Several electronic components connected or
plugged at a time can destroy each other!

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

609

RE 29681/06.05
Replaces: 07.02

Service case with test unit for


servo-valves without integrated
electronics

1/6

Type VT-SVTSY-1

Series 1X

H6100_d

Table of contents
Contents

Features
Page

Features

Ordering code

Test unit type VT-SVT-1-1X

Functional description / operating instructions

The service case includes a test unit with 9 V block battery


and optionally a power supply unit and connecting cable
(see ordering code)
The test unit is suitable for commissioning and servicing work
on hydraulic systems that are fitted with servo-valves without
integral electronics

Block circuit diagram / pin assignment

Test unit type VT-SVT-1-1X:Technical data

Allows functional testing and localisation of faults in the case


of machinery malfunction without removal of the servo-valve

Unit drawing

Voltage supply by 9 V block battery or 12 V power supply unit

Overview of servo-valves that are suitable for testing

Acccessories: Power supply unit type VT-SVTNT-2-1X/G12

Technical data

Service case:
Dimensions (W x H x D)
Weight
empty
complete

Accessories: Valve connecting cable

450 x 100 x 350 mm


2 kg
3.2 kg

Note:
The unit may only be used by personnel who are familiar with the
test unit, the valve and the hydraulic system. We will not assume
liability for damage caused by wrongful operation!
Information on available spare parts:
www.boschrexroth.com/spc

04

610
2/6

Bosch Rexroth AG

Hydraulics

VT-SVTSY-1

RE 29681/06.05

Ordering code

VT-SVTSY-1

1X

*
Further details in clear text

Service case with test unit


for servo-valves without integral electronics
Series 10 to 19
(10 to 19: unchanged technical data
and pin assignment)

0=
1=

= 1X

Test unit type VT-SVT-1-1X

Power supply unit 220 V/12 V:


Without power supply unit
With power supply unit type
VT-SVTNT-2-1X/G12

=1

Connecting cable for valves with electrical connection K9 or K31:


Without connecting cable
=0
With connecting cable type VT-SVTK-1-1X
=1
Connecting cable for valves with electrical connection K17:
Without connecting cable
With connecting cable type VT-SVTK-2-1X

=0
=1

Connecting cable for valves with electrical connection K8:


Without connecting cable
With connecting cable type VT-SVTK-3-1X

=0
=1

Ordering code for individual components

Designation

Type / ordering code

Material no.

VT-SVT-1-1X

R900214710

Connecting cable with cable socket Z31

VT-SVTK-1-1X

R900939983

Connecting cable with cable socket Z17

VT-SVTK-2-1X

R900939984

Connecting cable with cable socket Z8

VT-SVTK-3-1X

R900939985

Power supply unit 220V/12 V; 580 mA

VT-SVTNT-2-1X/G12

R900946388

Case, aluminium

R900219817

Test unit for servo-valves without integral electronics

Service case (empty)

611
RE 29681/06.05

3/6

Hydraulics Bosch Rexroth AG

VT-SVTSY-1

Test unit type VT-SVT-1-1X


The test unit is suitable for controlling and testing the function
of servo-valves without integral electronics.
Voltage is supplied to the test unit either by a 9V block battery
(included in the scope of supply) or optionally by a 12V power
supply unit type VT-SVTNT-2.

H6101_d

Functional description / operating instructions


Bring command value potentiometer [4] to the central
position

Valve testing is carried out as follows:


Connect the connecting cable of the power supply unit to
the socket [6] of the test unit or insert battery [11]

Use a suitable valve connecting cable (see ordering code) to


connect the test unit (socket [7]) with the servo-valve
(The valve connecting cables are to be wired so that the two
coils of the servo-valve are connected in series.)

Set function switch [1] to ON LED power [8] lights up


For battery operation, carry out battery test:
Set selector switch [3] to 50 mA
Set command value potentiometer [4] to 100 %
Actuate push-button [2] for battery test
The test unit indicates the battery charge in %

Turn command value potentiometer [4] slowly anti-clockwise


or clockwise and observe the movement of the motor or
cylinder
With a fully functional servo-valve, the motor or cylinder can
be sensitively controlled and moved in the required direction
or to the required position.

Select coil type of the valve using selector switch [3] on the
test unit

Block circuit diagram / pin assignment


Plug-in power supply
unit
VT-SVTNT-2-1X/G12

1
9
10

2
u

Servo-valve

3
11

04

1 mA
5 mA
7,5 mA
20 mA
30 mA
50 mA

Function switch

Coil current indicator

power LED

Pushbutton for battery test

Socket for power supply cable

Voltage regulator

Selector switch for type of coil

(with changeover switch)

10 Output stage

Command value potentiometer

Socket for valve connecting cable

11 9 V block battery

612
4/6

Bosch Rexroth AG

Hydraulics

VT-SVTSY-1

RE 29681/06.05

Test unit type VT-SVT-1-1X:


Technical data (for applications outside these parameters, please consult us!)
Operating voltages:
Battery operation

UO 9 V (E-block)

Operation with power supply unit

UO 12 V to 16 V

Current consumption of the test unit

I 20 mA (plus valve current)

Dimensions (W x H x D)

95 x 158 x 45 mm

Weight

m 0.34 kg

Unit drawing
1
2
3
4
5
6
7
8

Function switch
Pushbutton for battery test
Selector switch for type of coil
Command value potentiometer
Coil current indicator (in %)
Socket for power supply unit cable
Socket for valve connecting cable
power LED

Assignment of coil data to valve types:


5 mA / 500 per coil
4WS2E.10-4X
7.5 mA / 200 per coil
20 mA / 80 per coil
4WS2E.10A-4X
30 mA / 40 per coil
4DS1EO2-1X
50 mA / 28 per coil
3DS2EH10-2X
30 mA / 100 per coil

4WS2EM6-2X
4WS2EM10-5X

30 mA / 100 per coil


50 mA / 80 per coil

4WS2EM6-1X

50 mA / 80 per coil

4WS2EM16-2X

8
2
+

7,5 mA 20 mA
30 mA
5 mA
1 mA
50 mA

Command

max. Current

OFF

1
Overview of servo-valves that are suitable for testing
At the time of publishing this data sheet, the following Rexroth servo-vavles
can be tested with the VT-SVT-1 test unit:
Valve type

12 V

0V

Electrical connection

Type of connecting cable

4WS2EM6-1X

K17

VT-SVTK-2-1X

4WS2EM6-2X

K17

VT-SVTK-2-1X

4WS2EM10-5X

K31

VT-SVTK-1-1X

4WS2EM10-4X

K8

VT-SVTK-3-1X

4WS2EB10-4X

K8

VT-SVTK-3-1X

4WS2EM10A-4X

K8

VT-SVTK-3-1X

4WS2EB10A-4X

K8

VT-SVTK-3-1X

4WS2EM16-2X

K8

VT-SVTK-3-1X

4DS1E02-1X

K8

VT-SVTK-3-1X

3DS2EH10-2X

K8

VT-SVTK-3-1X

100 %

ON

+ 100 %

613
RE 29681/06.05

Hydraulics Bosch Rexroth AG

VT-SVTSY-1

5/6

Acccessories: Power supply unit type VT-SVTNT-2-1X/G12


Plug-in power supply unit 220 VAC 12 VDC; 580 mA

H6102_d

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

U 230 VAC 10 %; 50 Hz

Current consumption

I 60 mA

Fuse (thermal fuse)

t 130 C

Output voltage
Length of the connecting cable to the test unit
Dimensions (W x H x D)
Weight

U 12 VDC; 580 mA
I 2m
96 x 58 x 48 mm
m 0.38 kg

04

614
6/6

Bosch Rexroth AG

Hydraulics

VT-SVTSY-1

RE 29681/06.05

Accessories: Valve connecting cable


Connecting cable type VT-SVTK-1-1X
Connecting cable between VT-SVT-1 test unit and servo-valves
without integral electronics (valves with ordering code K9 or K31
for electrical connection)
The servo-valve coils are connected in series.

Technical data (for applications outside these parameters, please consult us!)
Valve connection

Plug-in connecor to E DIN 43563-BF6-3/Pg11 (series circuit)

Test unit connection

Mono jack plug 2,5 mm

Cable length
Weight

l 3m
m 0.16 kg

Connecting cable type VT-SVTK-2-1X


Connecting cable between the VT-SVT-1 test unit and servo-valves
without integral electronics (valves with ordering code K17 for
electrical connection)
The servo-valve coils are connected in series.

Technical data (for applications outside these parameters, please consult us!)
Valve connection

Plug in-connector VG 95328 (series circuit)

Test unit connection

Mono jack plug 2,5 mm

Cable length
Weight

l 3m
m 0.3 kg

Connecting cable type VT-SVTK-3-1X


Connecting cable between the VT-SVT-1 test unit and servo-valves
without integral electronics (valves with ordering code K8 for
electrical connection)
The servo-valve coils are connected in series.

Technical data (for applications outside these parameters, please consult us!)
Valve connection

Plug in-connector 14S-2P (series circuit)

Test unit connection

Mono jack plug 2,5 mm

Cable length
Weight

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

l 3m
m 0.16 kg

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

615

Service case with test unit for


servo and proportional valves
with integral electronics (OBE)

RE 29685/11.04
Replaces: 02.03

1/12

Type VT-VETSY-1

Series 1X

H/A/D 5967/98

Table of contents
Contents

Features
Page

Features

Ordering code, preferred types

Test unit type VT-VET-1-1X:


Functional description and operating instructions

Block circuit diagram / pin assignment

Technical data

Unit drawing

Connections, indicator and adjustment elements

Overview of servo and proportional valves that can be tested 9

The service case comprises a test unit as well as optional


power supply units, connecting cables and adapter cables
(see ordering code)
The test unit can be used to control and carry out functional
tests on servo and proportional valves with integral electronics
and operating voltages of 15 V or + 24 V
Simplifies commissioning and troubleshooting in hydraulic
systems with servo and proportional valves
Service case:
Dimensions
Weight

(W x H x D)
empty
complete

450 x 100 x 350 mm


2 kg
4.3 kg

Accessories:
Power supply unit type VT-VETNT-3-1X/G24

10

Power supply unit type VT-VETNT-2-1X/G15

10

Connecting cable type VT-VETK-1-1X

11

Adapter cable type VT-VETAK-1-1X

11

04
Caution:
The test unit may only be used by persons who are familiar with
the unit, the valve and the hydraulic system. When set
accordingly, the unit ignores control signals that come from the
system. If safety features are provided on the control side, these
are deactivated.
We assume no responsibility for damage caused by maloperation!

616
2/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VETSY-1

RE 29685/11.04

Ordering code

VT-VETSY-1

1X

Service case with test unit for servo


and proportional valves with integral
electronics
Series 10 to 19
(10 to 19: unchanged technical data
and pin assignment)

Further details in clear text


= 1X

Test unit type VT-VET-1-1X

0=
1=

=1

Connecting cable to valve:


Without connecting cable
With 1 off 6-pin connecting cable type VT-VETK-1-1X
With 2 off 6-pin connecting cable type VT-VETK-1-1X
Adapter cable for valve type 4WSE2EM6-1X:
Without adapter cable
With adapter cable type VT-VETAK-1-1X

Preferred types
Type

Material no.

VTVETSY11X/1-1-0-1-0

R900943515

VTVETSY11X/1-1-0-0-0

R900945527

VTVETSY11X/1-1-1-1-1

R900951686

VTVETSY11X/1-2-1-1-1

R900951687

VTVETSY11X/1-1-1-0-0

R900962782

Preferred types and standard components are


highlighted in the EPS (standard price list).

=0
=1
=2

0=
1=
=0
=1

Power supply unit


220 V / 15 VDC; 0.25 A:
Without power supply unit
With power supply unit
type VT-VETNT-2-1X/G15
Power supply unit
90 - 265 VAC / + 24 VDC; 2.2 A:
Without power supply unit
With power supply unit
type VT-VETNT-3-1X/G24

617
RE 29685/11.04

Industrial Hydraulics Bosch Rexroth AG

VT-VETSY-1

3/12

Test unit type VT-VET-1-1X


This test unit can be used to control and carry out functional
tests on servo and proportional valves with integral electronics
and an operating voltage of 15 V or + 24 V.
Operating modes:
External operation looping in of the operating voltage and
the command values from the control cabinet to the valve
Internal/external operation command value feedforward
via the test unit; operating voltage from the control cabinet

Command value provided via the BNC socket operating


voltage optional

H/A 5315/95

Internal operation operating voltage provided by a separate power supply unit; command value feedforward via the
test unit

Typ VT-VET-1-1X

Functional description and operating instructions


Voltage supply
The test unit can be supplied with + 24 V or 15 V, depending on the operating voltage required by the valve. To this end,
the "power selector" switch must be set accordingly before
commissioning.
An internal DC/DC converter generates the required auxiliary
voltages of 15 V for the internal command value signal.
The "power selector" switch connects, among other things, the
internal reference potential L0 to the mass potential applied
externally.
Switch position "+ 24 V" input pin B = reference potential
Switch position " 15 V" input pin C = reference potential
Connections

voltages of + 24 V or 15 V (depending on valve type) must


be available.
If the operating voltage is not provided from the control cabinet, an appropriate power supply unit can be connected to the
ES input plug.
Output socket AB (item 16) and 4 mm output sockets:
Output socket AB on the right-hand side is used for connecting the valve. The 4 mm sockets on the right-hand side are directly connected to the pins of output socket AB.
All the signals to or from the valve can therefore be measured
at the 4 mm sockets.
The short-circuit plugs can be used to separate each individual wire of the connecting cable to allow, for example, current
measurements.

Input plug ES (item 1) and 4 mm input sockets:

BNC socket:

Input plug ES on the left-hand side is used for connecting the


cable coming from the control or the control cabinet. The 4 mm
sockets on the left-hand side are connected directly with the
pins of the ES input plug in accordance with the setting of the
operating elements (see operating and indicator elements).

An externally generated command value signal may be fed in


via a standard 50 cable at the BNC socket.

All signals coming from the control can therefore be measured


at the sockets.

PE socket:

To operate the test unit and the valve the required operating

For this, the "setpoint selector" switch must be set to position


"BNC.
The PE socket is directly connected to the PE connection of
the ES input plug. Output socket AB does not have a PE connection.

Potentiometers / trimming potentiometers


Designation

Function

Preconditions

Setpoint intern

Command value signal to valve (AB pin D). The output switches automatically between
Ucomm = 10 V or Icomm = 20 mA
according to the load impedance of the
valve command value input.

Operating voltage present at input switch ES

Adjustment of the step-input


amplitude. The step function can be
activated using the "stepfunction key"
pushbutton.

Operating voltage present at input switch ES

Stepfunction level

power selector" switch position according to operating


voltage
"setpoint selector" switch set to "intern
"stepfunction key" pushbutton not pressed

"power selector" switch position according to operating


voltage
"setpoint selector" switch set to "intern"
The step function is generated by pressing the "stepfunction
key" pushbutton.

04

618
4/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VETSY-1

RE 29685/11.04

Functional description and operating instructions (continued)


LED-lamps
Designation

Function

Preconditions

power

Indication of internal voltage supply

Operating voltage at input switch ES

enable
indication
control

Indication of enable signal coming from the control/


control cabinet
(input socket ES - pin C)

Operating voltage is + 24 V
"power selector" switch to position 24 V
"power" LED lights up

enable
indication valve

Indication of the enable signal going to the valve


(output socket AB - pin C and measuring socket C).
The LED also lights up, as soon as an enable signal
is applied to the 4 mm measuring socket C. Without
a short-circuit plug, this signal is not applied to output
socket AB, but to the valve.

Operating voltage is + 24 V
"power selector" switch to position 24 V
"power" LED lights up
Enable signal is activated

Switches
All the functions described are only valid as long as all short-circuit links are plugged!
Designation

Switch position

Function

power selector

+ 24 V

Internal reference potential is connected to ES - pin B (0 V to UB = 24 V).


The enable signal can be generated using switch "enable (on) or be switched off (off).

15 V

Internal reference potential is connected to ES - pin C (0 V to UB = 15 V).


Enable signal generation deactivated.
ES - pin C is directly connected to AB - pin C (short-circuit link).

enable
on
(only with
24 V operation)

setpoint
selector

"setpoint-selector" switch to position control


an external enable signal applied by the control (ES - pin C) is switched through.
"setpoint-selector" switch to position intern or BNC
The enable signal for the valve is set.

off

The enable signal output (AB - Pin C) is connected to the reference potential (0 V) at low
resistance.

control

The command value lines are connected directly from the control to the valve via pin D and
pin E.
If the "power selector" is at position 24 V and
the "enable" switch is set to on
then the enable signal is switched through from the control to the valve (pin C).

intern oder BNC

"power selector" switch to position 24 V


The enable signal is fed to the valve as with the "enable" switch position.
The reference potential for the command value (AB - pin E) corresponds to the internal
reference potential (0 V).

intern

If the "stepfunction key" pushbutton is not actuated


then the command value signal to the valve (AB - pin D) is as preselected by means of
command value potentiometer "setpoint intern".
If the "stepfunction key" pushbutton is actuated
then the command value signal to the valve (AB - pin D) is as preselected by means of
trimming potentiometer "stepfunction level".

BNC

The signal applied to the BNC socket is used as command value signal and fed to the
valve (AB - pin D).

Pushbutton
Designation

Function

Preconditions

stepfunction
key

Changeover between command value signals "setpoint intern" and "stepfunction level" (pushbutton
actuated)

Operating voltage applied to input switch ES. "power


selector" switch position according to the operating
voltage type.
"setpoint selector" switch to "intern"

+ 15 V

15 V

0V

Protetctive earth

Command
value +

Command
value

Actual value

+ 24 V

0V

Enable or reference potential


for actual valve
value, e.g. with
4WRSE

Protetctive earth

Command
value +

Command
value

Actual value

PE

+ 24 V

15 V

Valve version with


operating voltage

Pin

Valve version
with operating
voltage

Pin assignment

11

gelb/grn

power

13

+ 15 V
L0 = 0 V
15 V

control
intern
BNC

DC

15 V

+ 24 V

DC

T1

u
u/i

17

10

18

off
on

yellow

grey

white

black

blue

red

X6

X5

X4

X3

X2

X1

14

12

yellow

grey

white

black

blue

red

16

VT-VETSY-1

PE

RE 29685/11.04

619
Industrial Hydraulics Bosch Rexroth AG
5/12

Block circuit diagram / pin assignment

04

620
6/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VETSY-1

RE 29685/11.04

Technical data (for applications outside these parameters, please consult us!)
Operating voltages
"power selector" switch:
Switch position "24 V"

UB

24 V; 20 % + 40 %

Switch position " 15 V"

UB

15 V; 10 %

Current consumption of the test unit

Max. current carrying capacity of pins A and B of input plug


ES and output socket AB when testing 24 V proportional
or high-response control valves
Imax

0.1 A

6A

Input:
Input plug ES
Command values to pins E and D

Ui; Ii

Enable signal to pin C (24 V operation) not active


active

according to valve details

UE

0 to 10 V

UE

16 to UB

Output socket AB
Actual value to pin F

Ui; Ii

BNC socket

Ui

according to the actual value output of the valve


0 bis 10 V

Outputs (all short-circuiting links plugged):


Input plugES
U 0; I0

Actual value to pin in F

according to the actual value output of the valve

Output socket AB
Enable signal to pin C (24 V operation)
"setpoint selector" switch
Switch position "intern" or "BNC"
"enable" switch to position "off"

UE

0V

"enable" switch to position "on"

UE

UB

"enable" switch to position "off"

UE

0V

"enable" switch to position "on"

UE

according to pin C of input plug ES

Switch position "control"

Command values to pins D and E


"setpoint selector" switch
Switch position "intern" or "BNC"

pin E
pin D

Reference potential
Ucomm
Icomm

Switch position "control"

pins E and D Ucomm

Dimensions (W x H x D)
Weight

0 to 10 V, falls Ri valve > 500


0 to 20 mA, falls Ri valve < 500
according to input plug ES (pins E and D)
94 x 54 x 160 mm

0.36 kg

621
RE 29685/11.04

Industrial Hydraulics Bosch Rexroth AG

VT-VETSY-1

7/12

Unit drawing
1

16

VET-1

2
15V
24V
power selector

15
3

15
A

power

14
B

enable indication

13

+/0

control

valve
+

12

setpoint/differential input
E

11
level

feedback
signal F
PE

actual
value

enable
intern
control

10

step
function

on

off

0
BNC

key

8
setpoint
selector

100%

setpoint
intern

For the item numbers, see page 8

+100%

04

622
8/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VETSY-1

RE 29685/11.04

Description of connections and indicator and adjustment elements


Functional element

Position 1)

Labelling

Input plug ES:

Connection on the control side using component plug K31,


CM02E14S-61P
Switch for selecting the operating voltage required by the valve

power selector

Readiness for operation

power

Enable signal of input plug ES and from the external control


to pin C

enable indication control

LED lamps:

Enable signal to measuring sockets, output socket AB and pin C

enable indication valve

13

Input measuring sockets

A to F and PE

Switch for selecting the command value signal source

setpoint selector

BNC socket for the connection of an external, independent command value encoder

Potentiometer for adjusting the internal command value signal

setpoint intern

Pushbutton for selecting between internal command value signals


for the generation of a step-change signal

stepfunction key

Enable switch for the generation of an enable signal that is independent of an external control

release intern

10

Trimming potentiometer for adjusting the amplitude of the internal


step function generator

stepfunction level

11

Current / voltage output for the valve command value with automatic
changeover between U0 = 0 V to 10 V
or I0 = 0 mA to 20 mA

17

Short-circuiting links for the separation of individual cable strands in


the connection from the control to the valve

14

Output measuring sockets for checking the signals in the valve connecting cable

A to F

12

Output socket AB:

16

Connection on the valve side using an MS3108A-14S-6S flanged


socket
Voltage converter DC/DC for the internal voltage supply

18
1)

The item numbers refer to the unit


drawing and block circuit diagram

Notes:
Operating mode without enable input

Operating mode with enable input

Valves with integral electronics and an operating voltage of


+ 24 V without enable input use connection C as reference
potential for the actual valve value. In this case, the "enable"
switch must be set to "off".

Valves with integral electronics and an operating voltage of


+ 24 V with enable input use connection B as reference potential for the actual valve value. In this case, the "enable" switch
must be set to "on.

623
RE 29685/11.04

VT-VETSY-1

Industrial Hydraulics Bosch Rexroth AG

9/12

Overview of servo and proportional valves that can be tested


At the time of publicizing this data sheet, the following servo and proportional valves of Bosch Rexroth can be tested with the VT-VET-1-1X
test unit:
Valve type

Operating voltage UB

Servo-valve with integral electronics (OBE)


4WSE2EM6 (without electrical position feedback)

15 V

4WSE2EM10(A)-4X (without electrical position feedback)

15 V

4WSE2EE10(A)-4X

15 V

4WSE2EM10-5X (without electrical position feedback)

15 V

4WSE2ED10-5X

15 V

4WSE2EM16(A) (without electrical position feedback)

15 V

4WSE2ED16(A)

15 V

4WSE3EE16

15 V

4WSE3EE25

15 V

4WSE3EE32

15 V

4DSE1EO2 (without electrical position feedback)

15 V

3DSE2EH10 (without electrical position feedback)

15 V

Proportional and high-response valves with integral electronics (OBE)


4WRAE (without electrical position feedback)

+ 24 V

4WREE

+ 24 V

4WRSE(H)

+ 24 V

4WRKE

+ 24 V

4WRTE

+ 24 V

4WRGE

15 V or + 24 V

4WRDE

15 V or + 24 V

.WRCE

15 V or + 24 V

FESE (ab Serie 2X)

+ 24 V

3FERE

+ 24 V

.WRZE (without electrical position feedback)

+ 24 V

DBEE (without electrical position feedback)

+ 24 V

DBEME (without electrical position feedback)

+ 24 V

DBEMTE (without electrical position feedback)

+ 24 V

DBETE (without electrical position feedback)

+ 24 V

DBETRE (without electrical position feedback)

+ 24 V

ZDBEE (without electrical position feedback)

+ 24 V

STW on enquiry
DREE (without electrical position feedback)

15 V or + 24 V
+ 24 V

04

624
10/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VETSY-1

RE 29685/11.04

Accessories: Power supply units


Power supply unit type VT-VETNT-3-1X/G24

H 6847

Desktop version 90-265 VAC 24 VDC; 2.2 A

Typ VT-VETNT-3-1X/G24

Technical Data (for applications outside these parameters, please consult us!)
Operating voltage
Current consumption

U
I

Fuse
Output voltage

max. 1.5 A
Electronic overload protection

Supply cable length

Cable length to test unit

Dimensions (W x H x D)
Weight

90-265 VAC; 47-63 Hz

24 VDC 1 V; 2.2 A
approx. 1.5 m
approx. 1.5 m
135 x 65 x 41 mm

0.4 kg

Power supply unit type VT-VETNT-2-1X/G15

H 6846

Plug version 115 VAC / 230 VAC 15 VDC; 0.25 A

Typ VT-VETNT-2-1X/G15

Technical Data (for applications outside these parameters, please consult us!)
Operating voltage
Current consumption

U
I

Fuse
Output voltages
Cable length to the test unit

< 29 mA
Thermal link 130C

U
l

Dimensions (W x H x D)
weight

115 V / 230 V 5 % 50/60 Hz can be changed over

+ 15 VDC 0.2 V; 0.25 A


15 VDC 0.2 V; 0.25 A
2m
86 x 56 x 86 mm

0.63 kg

625
RE 29685/11.04

Industrial Hydraulics Bosch Rexroth AG

VT-VETSY-1

11/12

Accessories: Connecting and adapter cables


Connecting cable type VT-VETK-1-1X
Connecting cable between the VT-VET-1-1X test unit and
servo and proportional valves with integral electronics (valves
with the electrical connection ordering codes K9 and K31)

Technical data (for applications outside these parameters, please consult us!)
Valve connection

Plug-in connector to DIN EN 175201-804

Test unit connection

Plug MS3101A 14S 6P

Connecting cable length


Weight

l
m

3m
0.3 kg

Notes:
To achieve greater lengths, several cables can be joined
together.
When operating valves with an electrical connection K31, the
earth is interrupted.

Adapter cable type VT-VETAK-1-1X


Adapter cable between the VT-VET-1-1X test unit and servo
and proportional valves with integral electronics (valves with
electrical connection ordering code K17).

Technical data (for applications outside these parameters, please consult us!)
Valve connection

Plug-in connector VG 95 328

Test unit connection


Connecting cable length
Weight

Plug MS3101A 14S 6P


l
m

3m
0.3 kg

04

626
12/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VETSY-1

RE 29685/11.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengiesser 1
97816 Lohr am Main, Germany
Telephone +49 (0) 93 52 / 18-0
Fax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

627

RE 08008/06.05
Replaces: 03.04

Line connectors for valves


and sensors

1/12

Various versions
in plastic and metal

Overview of Contents
Contents
Ordering range

Features
Page
2 and 3

Line connectors are generally accessories and are not always


supplied with the valves or sensors
Plastic and metal versions
Various types and standards
Line connectors for solenoids, position sensors and pressure
sensors, valves with / without on-board electronics
See ordering range for types and standards
Line connectors available as
cubic, concentric and right-angle connectors
Jet connectors
Kostal connectors
line connectors with cable

04

628
2/12

Bosch Rexroth AG

Hydraulics

Line connectors

RE 08008/06.05

Ordering range
Description
2P+PE
Pg9, Pg11, M16 x1.5

Line connectors for solenoids


DIN 43650
ISO 4400
NFE 48441

grey

m
(kg)

Details
on page

Material number

0.03

1 834 484 058

black

1 834 484 057

with LED

1 834 484 136


1 834 484 137
1 834 484 103

with free-wheeling
diode and LED

1 834 484 138


1 834 484 139

with rectifier

1 834 484 134


1 834 484 135

3P+PE / M16 x1.5

Line connector for


pressure switches and sensors
DIN 43650
ISO 4400
NFE 48441

black

0.03

3P+PE / Pg11

Line connectors for


pressure switches

with indicator lamp

0.06

with LED

0.08

Line connectors for


position tranducers and
pressure sensors

grey

0.02

3P / Pg7

Line connector for


position sensor AC/AC

black

0.05

1 834 484 040

6P+PE / Pg11

Line connector for


valves with on-board
electronics,
plastic

soldered

0.05

1 834 482 022

6P+PE / Pg11

Line connector for


valves with on-board
electronics,
plastic

crimped

0.05

1 834 482 026

6P+PE / Pg11

Line connector for valves


with on-board electronics,
right-angle,
plastic

crimped

0.05

1 834 484 252

4P / Pg7

1 834 484 060

1 834 484 044


1 834 484 078

black

1 834 484 061


1 834 484 063

629
RE 08008/06.05

Line connectors

Hydraulics

Bosch Rexroth AG

3/12

Ordering range
Description

m
(kg)

Details
on page

Material number

6P+PE / Pg11

Line connector for valves


with on-board electronics,
metal

crimped

0.08

1 834 482 023

6P+PE / Pg16

Line connector for valves


with on-board electronics,
metal

crimped

0.09

1 834 482 024

11P+PE / Pg16

Line connector for valves


with on-board electronics,
plastic

crimped

0.05

1 834 484 142

4P / Pg7

Line connector for sensors,


plastic

soldered

0.05

10

1 834 484 140

4P

Line connector for sensors,


metal

soldered

0.04

10

1 834 484 141

4P / M12 x1

Line connectors with cable


for valves with position
display

straight, 5 m cable

0.12

11

1 834 463 013

straight, 10 m cable

0.45

1 834 463 030

right-angle, 5 m cable

0.10

1 834 463 014

right-angle, 10 m cable 0.445


4P+PE / M12 x1

2P

Line connectors with cable


for valves with central
connection

Jet connector (Junior Timer)

right-angle, 5 m cable

0.25

1 834 463 031


11

right-angle, 10 m cable 0.5

1 834 463 027


D 831 003 900

straight

0.031 12

1 834 484 094

right-angle

0.038

1 834 484 095

3P

Jet connector (Junior Timer)

straight

0.04

1 237 000 039

2P

Kostal connector,
right-angle

soldered

0.031 12

1 834 484 046

04

630
4/12

Bosch Rexroth AG

Hydraulics

Line connectors

RE 08008/06.05

Unit dimensions (nominal dimensions in mm)


2P+PE

Cable 511-mm

Pg9, Pg11,
M16 x 1.5

U A [V=]

With rectifier*
for

240
220
200
180

~
UE
115/50
115/60
230/50
230/60
240/50

160

VDR

140

* For direct voltage only

120
100
80

UA

60
40

UA
96/00
205/00
220/00

Description

Standard
With LED

20
0
20 40 60 80 100 120 140 160 180 200 220 240

U E [V=]

DIN 43650
ISO 4400
NFE 48441

Material no.

M16 x 1,5 Grey

1 834 484 058

Black

1 834 484 057

1 834 484 136

1 834 484 137

Pg11

15...30 V DC

Pg91

230 V~

1 834 484 103

With free-wheeling diode


and LED

Pg11

20...30 V DC

1 834 484 138

1 834 484 139

With rectifier

Pg11

1 834 484 134

1 834 484 135

631
RE 08008/06.05

Line connectors

Hydraulics

Bosch Rexroth AG

5/12

Unit dimensions (nominal dimensions in mm)


3P+PE

Cable 5...11 mm
M16 x 1.5

Description

DIN 43650
ISO 4400
NFE 48441

Standard

M16 x 1.5

Material no.

Black

1 834 484 060

3P+PE

15

34

Cable
4...11
mm mm
Kabel
411
green yellow

39

72

1,5

Pg11

1
+

3
+

GDMEN

M3
34
Description
With LED display

Material no.
Pg11

(1x)

12...28 V DC

1 834 484 044

(2x) 12...24 V DC

1 834 484 078

04

632
6/12

Bosch Rexroth AG

Hydraulics

Line connectors

RE 08008/06.05

Unit dimensions (nominal dimensions in mm)


4P

Cable 4 x 0.25 mm2


green
brown

yellow
white
Saeling ring

Pg7
Solder terminals (4x)

Description
Line connector

Material no.
Pg7 Grey

1 834 484 061

Black

1 834 484 063

3P
Tightening torque 0.5+0.3 Nm

Cable 6 8 mm

After soldering, insert receptacle in


such a way that locking lug engages
in cut-out.

35 mm
Length when fitted: 56 mm

Description
Line connector AC/AC

Material no.
Pg7 Black

1 834 484 040

633
RE 08008/06.05

Line connectors

Hydraulics

Bosch Rexroth AG

7/12

Unit dimensions (nominal dimensions in mm)


6P+PE

Cable 511 mm

Insulated cable

AB
Solder side

30 mm
Length when fitted: 78 mm + Pg

Description

Material no.

Line connector

Pg11 Plastic

soldered

1 834 482 022

6P+PE

Cable 711 mm

AB
Crimp side

27 mm
Length when fitted: 75 mm + Pg

Messrs. Amphenol-Tuchel

Part number

Crimping tool

TA 0000
TA 0000 163
TA 0002 146001

Contact remover

FG 0300 146-(1)

Contact

0.5...1.5 mm2

* VN 2016-0002(1) Individual contacts in packed unit of 100


* ZN 2016-0002(1) Contact strip, pack of 200
* HN 2016-0002(1) Contact strip, pack of 2,000

Description
Line connector

2016 0002 (1)*

Material no.
Pg11 Plastic

Crimped

1 834 482 026

04

634
8/12

Bosch Rexroth AG

Hydraulics

Line connectors

RE 08008/06.05

Unit dimensions (nominal dimensions in mm)


6P+PE

Cable 7...11 mm
Pg11
Messrs. Amphenol-Tuchel

Part number

Crimping tool

TA 0000
TA 0000 163
TA 0002 146001

Contact remover

FG 0300 146-(1)

Contact
AB
Crimp side

0.5...1.5 mm2

2016 0002 (1)*

* VN 2016-0002(1) Individual contacts in packed unit of 100


* ZN 2016-0002(1) Contact strip, pack of 200
* HN 2016-0002(1) Contact strip, pack of 2,000

30 mm
Length when fitted: 62 mm + Pg
Description

Material no.

Line connector

Pg11 Right-angle

Crimped

1 834 484 252

6P+PE
Pg11

Cable 7...11 mm

AB
Crimp side

Messrs. Amphenol-Tuchel

Part number

Crimping tool

TA 0000
TA 0000 163
TA 0002 146001

Contact remover

FG 0300 146-(1)

Contact

28 mm
Length when fitted: 68 mm + Pg

0.5...1.5 mm2

* VN 2016-0002(1) Individual contacts in packed unit of 100


* ZN 2016-0002(1) Contact strip, pack of 200
* HN 2016-0002(1) Contact strip, pack of 2,000

Description
Line connector

2016 0002 (1)*

Material no.
Pg11 Metal

Crimped

1 834 484 023

635
RE 08008/06.05

Line connectors

Hydraulics

Bosch Rexroth AG

9/12

Unit dimensions (nominal dimensions in mm)


6P+PE
Pg16

Pg seal

Cable 7...11 mm

AB
Crimp side

Messrs. Amphenol-Tuchel

Part number

Crimping tool

TA 0000
TA 0000 163
TA 0002 146001

Contact remover

FG 0300 146-(1)

Contact

0.5...1.5 mm2

2016 0002 (1)*

* VN 2016-0002(1) Individual contacts in packed unit of 100


* ZN 2016-0002(1) Contact strip, pack of 200
* HN 2016-0002(1) Contact strip, pack of 2,000

28 mm
Length when fitted: 69 mm + Pg
Description

Material no.

Line connector

Pg16 Metal

Crimped

1 834 482 024

11P+PE
Pg16

Cable 7...11 mm

AB
Crimp side

Messrs. Hirschmann

Part number

Crimping tool

XZC 0700

Contact remover

XWA 164

Contact

0.5...1.5 mm2

RBC 162

28 mm
Length when fitted: 69 mm + Pg
Description
Line connector

Material no.
Pg16 Plastic

Crimped

1 834 484 142

04

636
10/12

Bosch Rexroth AG

Hydraulics

Line connectors

RE 08008/06.05

Unit dimensions (nominal dimensions in mm)


4P

Pg7

22 mm
Length when fitted: 62 mm + Pg

Cable 4 x 0.25 mm2

Description

Material no.

Line connector

Pg7 Plastic

Soldered

1 834 484 140

4P

18 mm
Length when fitted: 74 mm with cable sleeve

Cable 4 x 0.25 mm2

Description
Line connector

Material no.
Metal

Soldered

1 834 484 141

637
RE 08008/06.05

Line connectors

Hydraulics

Bosch Rexroth AG

11/12

Unit dimensions (nominal dimensions in mm)


M12 x 1

4P

1 brown
2 white

3 blue
4 black

Screen in protective tube transparent


Line connector screened, 4 x 0.34 mm2
Cable sheath: grey PUR

Description
Line connector

4P Straight

Material no.

15 m

1 834 463 013

Straight

10 m

1 834 463 030

Right-angle

15 m

1 834 463 014

Right-angle

10 m

1 834 463 031

M12 x 1

31,5

04

26,5

20,5

45

1 brown
2 white
3 blue
4 black
5 green/yellow
to DIN EN 50044

5,6

4P+PE

M12x1
14,5

Housing and cable sheath: black PUR


5 x 0.34 mm2, Imax = 3 A

Description
Line connector

Material no.

5P Right-angle

15 m

1 834 463 027

Right-angle

10 m

D 831 003 900

638
12/12

Bosch Rexroth AG

Hydraulics

Line connectors

RE 08008/06.05

Unit dimensions (nominal dimensions in mm)

14,5

38

76

14,5

14,5

2P / 3P

Description

Material no.

Jet connector (Junior Timer) 2P


Jet connector (Junior Timer) 3P

Straight

1 834 484 094

Right-angle

1 834 484 095

Straight

1 237 000 039

40

25

12

10

2P

M27 x 1
30

Description
Kostal connector
Right-angle

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

Material no.
Soldered

1 834 484 046

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not release
the user from the obligation of own judgement and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.

639

Cable sockets
for controlling
electrically operated valves
and sensors

H5254

Cable sockets according to


DIN EN 175301-803 and ISO 4400,
2-pin+ PE, with standardised connecting cable, for electrically operated
valves with component plug "K4"

H5744

RE 08006/01.05
Replaces: 03.03

H 5743

Cable sockets for mechanical position switches and valves with central
connection with component plug
"K6" / "K"

Cable sockets according to


IEC 60947-5-2, for valves with inductive position switch "QM" and valves
with component plug "K24"

1/14

H 5745

Cable socket according to


DIN EN 175301-803 and ISO 4400,
2-pin+ PE, for electrically operated
valves with component plug "K4"

Table of contents
Contents

Page

Individual connection
Cable sockets according to DIN EN 175301-803 and
ISO 4400, 2-pin + PE

Cable sockets
2

Cable sockets for electrically operated directional valves


with component plug "C4" (AMP Junior-Timer)

Cable sockets for electrically operated directional valves


with component plug "K40" (Deutsch plug)

Cable sockets according to DIN EN 175301-803 and


ISO 4400, 3-pin + PE

for pressure switches with component plug "K14"

with standardised connecting cable for pressure switches with


component plug "K14"

10

12

for mechanical position switches and valves with central connection


with component plug "K6" / "K"

Cable sockets according to IEC 60947-5-2


4

with standardised connecting cable for electrically operated valves


with component plug "K4"

Cable sockets according to DIN EN 175301-803 and


ISO 4400, 3-pin + PE

Page

Central connection (terminal box)

for electrically operated valves with component plug "K4"

Cable sockets according to DIN EN 175301-803 and


ISO 4400, 2-pin + PE

Contents

13

for valves with inductive position switch "QM" and valves


with component plug "K24"

04

640
2/14

Bosch Rexroth AG

Industrial Hydraulics

Cable sockets RE 08006/01.05

Cable sockets according to DIN EN 175301-803 and ISO 4400, 2-pin + PE


for electrically operated valves with component plug "K4"

Ordering code
Designation:
Cable socket
Z4

DC
voltage

Symbol
1

Z45
2
Standard without
circuitry
Z5L

AC
voltage

Colour

Valve side

Fitting

Material
number

12 240 V

grey

M16 x 1.5

R901017010

12 240 V

black

M16 x 1.5

R901017011

12 240 V

brown

NPT 1/2"

R900004823

12 240 V

black

NPT 1/2"

R900011039

12 240 V

black

A/B

M16 x 1.5

R901017022

12 240 V

black

A/B

NPT 1/2"

R900057453

24 V

black

A/B

M16 x 1.5

R901017026

black

A/B

M16 x 1.5

R901017027

24 240 V

black

A/B

M16 x 1.5

R901017029

24 240 V

black

A/B

NPT 1/2"

R900057455

24 240 V

black

A/B

M16 x 1.5

R901017025

24 240 V

black

A/B

NPT 1/2"

R900842566

PE
1

Z55L
ge

With indicator lamp

2
PE
Z5L1
With indicator lamp
and Z-Diodenprotective coating

Limitation of cut-off voltage peak to 55 V

ge
2

2
PE

Z5L2
With indicator lamp
and protective diode

+1

+1

24 V
Limitation of cut-off voltage peak to 1 V

ge
-2

-2
PE

RZ5L

RZ55L
With indicator lamp
and rectifier

+1
2

ge

-2

PE
RZ5

RZ55

+1

With rectifier
2
PE

-2

641
RE 08006/01.05

3/14

Industrial Hydraulics Bosch Rexroth AG

Cable sockets

Technical data (for applications outside these parameters, please consult us!)
Ambient temperature

Standard

C 40 to + 125

With indicator lamp/


rectifier

C 20 to + 60

Type of protection according to DIN 40050

IP 65 with cable socket mounted and locked

Operating voltage

V See ordering code on page 2

Maximum operating
current

Standard

A 16

With indicator lamp

A 4

With rectifier

A 1,5

Current consumption of LED

mA approx. 10

LED

Yellow

Number of pins

2 + PE

Clamping range for cables having an outer diameter of

mm 5, up to 10
mm2 1.5

Maximum cable cross-section


Type of connection

Threaded connection

Unit dimensions:
With circuitry (in mm)

Unit dimensions:
Without circuitry (in mm)

45

27,5

2
2

GDM

10

1 Fixing screw M3,


tightening torque MT = 0,5 Nm
2 Fitting, see page 2

5,5

40

34,2

43

5,5

28
18

18

10A
250V

28

04

642
4/14

Bosch Rexroth AG

Industrial Hydraulics

Cable sockets RE 08006/01.05

Cable sockets according to DIN EN 175301-803 and ISO 4400, 2-pin + PE


with standardised connecting cable for electrically operated valves with component plug "K4"

Ordering code
Designation:
Cable socket

DC
voltage

Symbol

Z4

sw1

Standard without
circuitry

sw2

AC
voltage

Material number for cable length


Colour

3m

5m

10 m

12 240 V

black

R900032020 R900032014 R900217134

gnge

Z4L

With indicator
lamp

sw1

sw2
gnge

sw1

Z4L1
With indicator lamp
and Z-Diodenprotective coating

sw2
gnge

24 V

black

R900032050 R900032018 R900217135

90 130 V

black

R900032023 R900032012 R900217136

180 240 V

black

R900032024 R900032010 R900217137

24 V

black

R900032021 R900032015 R900217138

Limitation of the cutoff voltage peak to


55 V

Cable sockets with indicator lamp are provided with a yellow LED that signals the operational state.
With cable sockets with indicator lamp and 24 V suppressor circuit, the cut-off voltage peak is limited to approx. 55 V by a zener
diode circuit.
The cable sockets scope of supply includes a fixing screw and a flat seal (both captive).

Technical data (for applications outside these parameters, please consult us!)
Ambient temperature

Cable socket housing

C 20 to + 90

Rigidly mounted cable

C 20 to + 80

Flexibly mounted cable

C 5 to + 70

Type of protection according to DIN 40050

IP 67 with cable socket mounted and locked

Connecting cable

lflex 150 PVC, grey, with approbation: VDE, UL, CSA, SEV
mm2 3 x 1.0

Wire cross-section
Wire marking

Number of pins
Cable cross-section

PE

Green/yellow

Other wires

Black with figures. On the 2-pin electrical connection to


DIN EN 175 301-803, contacts 1 and 2 are assigned.
2 + PE
mm approx. 7

643
RE 08006/01.05

Industrial Hydraulics Bosch Rexroth AG

Cable sockets

5/14

Unit dimensions (in mm)

1 LED
2 DIN contacts, rotatable through 0 + 180

27
18

3 Flat seal (captive)


4 Nameplate

5 Fixing screw M3 (captive),


tightening torque MT = 0.5 Nm

27
47

30

3
5

04

644
6/14

Bosch Rexroth AG

Industrial Hydraulics

Cable sockets RE 08006/01.05

Cable sockets for electrically operated directional valves with component plug "C4"
(AMP Junior-Timer)

Ordering code
Designation:
Cable socket

Outer wire diameter in mm

Colour

Material number

2POL AMP JUNIOR D2.2

2.2 to 3.0

black

R901022127

2POL AMP JUNIOR D1.2

1.2 to 2.1

black

R900313533

Technical data (for applications outside these parameters, please consult us!)
Ambient temperature range

Permissible operating voltage range

V DC

Type of protection according to EN60529

20 to + 125
10 to 32
IP66A (correctly mounted and locked)

Maximum operating current

Number of pins

5
2

Permissible outer cable diameter


Maximum wire cross-section
Permissible outer single wire

mm

5.2 to 7

mm2

0.5 to 1

mm

2.2 to 3

Type of connection

Crimped connection

Condition when delivered

1 plug housing, 2 contacts,


2 single wire seal, 1 rubber sleeve,
not assembled, packed in a bag

Crimping tool

Basic crimping tool type 539635-1, make: AMP


Matrix type 539737-2, make: AMP

Unit dimensions (in mm)


Housing AMP
Type 282189-1

17

A
A-A

54

37,5

19,5

23,80,3

645
RE 08006/01.05

Industrial Hydraulics Bosch Rexroth AG

Cable sockets

7/14

Cable sockets for electrically operated directional valves with component plug "K40"
(Deutsch plug)

Ordering code
Designation:
Cable socket

Wire cross-section

Colour

Material number

2POL DT06 K40AWG14*BG

AWG14-16

grey

R900733451

2POL DT06 K40AWG16*BG

AWG16-18

grey

R901017847

Technical data (for applications outside these parameters, please consult us!)
Plug housing

DT06-2S-CE01

Ambient temperature range

Permissible operating voltage range

V DC

Type of protection according to EN60529


Maximum operating current

10 to 32
IP69K (correctly installed and locked)

Number of pins
Maximum wire cross-section

20 to + 125

5
2

AWG14-16

mm2

1.3 to 2.08

AWG 16-18

mm2

0.82 to 1.3

mm

1.35 to 3.05

Permissible outer diameter single wire


Type of connection

Crimped connection

Condition when delivered

1 plug housing, 2 contacts, 1 securing wedge,


not assembled, in bag

Crimping tool

Type HDT-4800, make: Compagnie Deutsch

16

Unit dimensions (in mm)

16

04

32

646
8/14

Bosch Rexroth AG

Industrial Hydraulics

Cable sockets RE 08006/01.05

Cable sockets according to DIN EN 175301-803 and ISO 4400, 3-pin + PE


for pressure switches with component plug "K14"

Ordering code
Designation:
Cable socket
Z14
Standard without
circuitry

DC
voltage

Symbol
1
2
3

AC
voltage

Colour

Fitting

Material number

1
2
3

12 240 V

black

M16 x 1.5

R901017012

12 V

black

M16 x 1.5

R901017030

1
2
3

24 V

black

M16 x 1.5

R901017048

48 V

black

M16 x 1.5

R901017032

110 V

black

M16 x 1.5

R901017035

220 V

black

M16 x 1.5

R901017037

24 V

black

M16 x 1.5

R901017040

PE
Z15L
1
2
3

ge
gn

With indicator
lamp
Z15L6
With indicator
lamp

-N
PE

1
2
3

1
2
3

ge
gn

-N
PE

Technical data (for applications outside these parameters, please consult us!)
Ambient temperature

Standard

C 40 to + 125

With indicator lamp

C 20 to + 60

Type of protection according to DIN 40050


Operating voltage
Maximum operating
current

IP 67 with cable socket mounted and locked


V See ordering code above

Standard

A 16

With indicator lamp

A 4

Current consumption of LED

mA approx. 10

Indicator lamp

Yellow / yellow + green

Number of pins

3 + PE

Clamping range for cables having an outer diameter of


Maximum wire cross-section
Type of connection

mm 5, up to 10
mm2 1.5
Threaded connection

647
Industrial Hydraulics Bosch Rexroth AG

Cable sockets

Unit dimensions:
Without circuitry (in mm)

Unit dimensions:
With circuitry (in mm)
45

27,5

28

M16 x 1,5
2

28
18

3
GDM

10

40

34,2

43

1
1

5,5

5,5

M16 x 1,5

18

10A
250V

9/14

RE 08006/01.05

1 Fixing screw M3,


tightening torque MT = 0.5 Nm

04

648
10/14

Bosch Rexroth AG

Industrial Hydraulics

Cable sockets RE 08006/01.05

Cable sockets according to DIN EN 175301-803 and ISO 4400, 3-pin + PE


with standardised connecting cable for pressure switches with component plug "K14"

Ordering code
Designation:
Cable socket

DC
voltage

Symbol

Z14

sw1

Without circuitry

sw2

sw3

AC
voltage

Material number for cable length


Colour

5m

10 m

12 240 V

black

R900619228

R900619229

24 V

black

R900225082

R900225083

gnge
Z14L

sw1
sw2
sw3

With indicator
lamp

1
2
3
gn

ge

sw4
gnge

Technical data (for applications outside these parameters, please consult us!)
Ambient temperature

Cable socket housing

C 20 to + 90

Cable rigidly mounted

C 20 to + 80

Cable flexibly mounted

C 5 to + 70

Type of protection according to DIN 40050

IP 67 with cable socket mounted and locked

Connecting cable
Wire cross-section

Wire marking

Number of pins
Cable cross-section

lflex 150 PVC, grey, with approbation: VDE, UL, CSA, SEV
Standard

mm2

With indicator lamp

mm2 5 x 0.5

4 x 0.75

PE

Green/yellow

Other wires

Black with figures. On the 3-pin electrical connection according


to DIN EN 175 301-803, contacts 1, 2 and 3 are assigned.
3 + PE
mm approx. 7

649
RE 08006/01.05

Industrial Hydraulics Bosch Rexroth AG

Cable sockets

11/14

Unit dimensions (in mm)

1 LED
2 Flat seal (captive)

27
18

2
3

3 Nameplate

PE

4 Fixing screw M3 (captive),


tightening torque MT = 0.5 Nm

1
27
47

30

2
4

04

650
12/14

Bosch Rexroth AG

Industrial Hydraulics

Cable sockets RE 08006/01.05

Cable sockets
for mechanical position switches and valves with central connection
with component plug "K6" / "K"
Ordering code
Component plug

DC
voltage

Standardisation

AC
voltage

Colour

Fitting

Material number

K6

according to DIN 43651

250 V

grey

Pg 11

R900002803

not standardised

250 V

red

Pg 11

R900005538

Technical data (for applications outside these parameters, please consult us!)
Ambient temperature

C 40 to + 90

Type of protection according to DIN 40050

IP 65 with cable socket mounted and locked

Operating current, contiuous


Number of pins

A 10

Component plug K6

6 + PE

Component plug K

4 + PE

Clamping range for cables having an outer diameter of

mm 7, up to 9
mm2 1.5

Maximum wire cross-section


Type of connection

Crimped connection

Unit dimensions:
Component plug K6 (in mm)

Unit dimensions:
Component plug K (in mm)

11max

29,5

15,2

1 Fixing screw M3,


tightening torque MT = 0.5 Nm

1
10

48

30
10

48

27,5

25,5

40

29,5

SW22

65

651
RE 08006/01.05

Industrial Hydraulics Bosch Rexroth AG

Cable sockets

13/14

Cable sockets according to IEC 60947-5-2


for valves with inductive position switch "QM" and valves with component plug "K24"

Ordering code
Designation, features:
Cable socket

Colour

Fitting

Material number

Cable socket suitable for K24 4-pin, M12 x 1 with threaded connection

black

Pg 9

R900031155

Cable socket suitable for K24-3m 4-pin, M12 x 1


with moulded-on PUR cable, 3 m long.

black

Pg 9

R900064381

black

Pg 9

R900082899

Cable cross-section: 4 x 0.34 mm2, cable approx. 5 mm


Wire marking:

1: brown
2: white
3: blue
4: black

Cable socket suitable for K24 4-pin, M12 x 1 with threaded connection,
angled.
Housing can be rotated around 4 x 90 in relation to contact insert.

Technical data (for applications outside these parameters, please consult us!)
Ambient temperature

C 40 to + 85

Type of protection according to VDE 0470

IP 67 with cable socket mounted and locked

Nominal voltage according to VDE 0110 group C

V 50 V DC

Nominal current per contact

A 3

Clamping range for cables having an outer diameter of

mm 6, up to 8
mm2 0.75

Maximum wire cross-section


Type of connection

Threaded connection

Cable cross-section

mm 6 to 8

Unit dimensions (in mm)


Cable socket suitable for K24 4-pin, M12 x 1 with
threaded connection, angled

M12 x 1

04
40

54

M12 x 1

19,6

Cable socket suitable for K24-3m 4-pin, M12 x 1


with moulded-on PVC cable, 3 m long

41,5

19,6

35

M12 x 1
19,6

Cable socket suitable for K24 4-pin, M12 x 1 with


threaded connection

652
14/14

Bosch Rexroth AG

Industrial Hydraulics

Cable sockets RE 08006/01.05

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

653

RE 29 761/12.02
Replaces: 10.89

K4607-11

f/U converter and monitoring


electronics FUW1
VTS 0102 S1X/...

VTS 0102 S1X/FUW1

Overview of contents
Contents
Features
Ordering details
Function

Technical data
Signal flow plan
Block circuit diagram and connection allocation
Unit dimensions

Page
1
2
2

3
4
5
6

Features
The f/U converter and monitoring electronic card is used in conjunction
with the VT 12000 to RE 29 736 closed loop control and monitoring
electronics and a digital rotary speed measurement system
(incremental transducer) for the closed loop control of the speed of
secondary units, if exacting requirements are placed upon the accuracy
of speed and an operational reliability.
Frequency/voltage conversion
Possible input signals:
Two input pulse trains offset by 90 with push-pull signals,
5 V to 15 V via a differential amplifier input
Sensing ratio 1 : 1,
Evaluation factor of 1:1, 2:1 or 4:1
or optionally:
One pulse train and one directional signal,
12 to 24 V via an opto coupler with a
sensing ratio of 1 : 1, 2x evaluation is possible
Frequency range 1 to 150 kHz, dependent upon the evaluation
Output signals:
Analogue voltage 10 V, proportional to the frequency
Directional and pulse chain outputs (dependent upon the
evaluation) as TTL signals

Monitoring:
Cable break - monitor for the incremental transducer
Frequency monitoring of both input pulse trains
Grouping of all the internal monitoring signals with the
monitoring signals diff, ndiff, nmax, amax, H1 of the
VT 12000 card and an additional input signal (e.g. for
an emergency stop facility or a centrifugal switch)
Enable/reset input
Input signals via opto couplers; the logic of these signals can
be inverted by means of DIP switches (high/low)
The individual monitored signals are stored and indicated
until reset either from the front panel button or the reset
input
Output signals as TTL signals, a 15 V signal, opto-coupler
switched output and a 24 V/1.2 A switched output for the
direct control of logic valves

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

VTS 0102

1/6

RE 29 761/12.02

04

654

Ordering details
VTS 0102
64-pin blade connection strip to DIN 41 612
form C
(for installation in a Euro-card magazine)
Series 10 to 19
(10 to 19 = unchanged installation and
connection dimensions)
Evaluation factor 1, 2 or 4

1X

FUW1

*
0=
1=

= 1X

Further details in clear text


Without cable break monitoring
With cable break monitoring
flimit in kHz

fnom. in kHz

Function
f/U converter
When 2 pulse trains are applied then the input signals from the
evaluation circuitry are split into the frequency and direction signals.
The evaluation factors of 1x, 2x or 4x can be selected via jumper B4,
thereby the input frequency can, for example, be multiplied by a factor
of 4. The subsequent f/U converter module converts the frequency
into a proportional analogue voltage. The convertion relationship is
pre-set in the laboratory and can be corrected by a few thousandths
via potentiometer P10, which is located on the front panel, on line
for fine tuning. The direction signal determines whether the analogue
voltage is positive or negative. The pre-sign can be inverted via jumper
B1.
When the frequency and direction signal are applied then the bridges
B2 and B3 must be repositioned; the pre-sign can be inverted at the
DIP switch SW1-3.
The conversion relationship is pre-selected via resistor R40; the value
is given by:
R40

4000

(in k) 6 k,

fnom. A
Where fnom. = Frequency in kHz without multi-evaluation at
Uout = 10 V
fnom. can be derived from:
Pulse rate of the impulse transducer nnom. in min1
60
A = Evaluation factor (1, 2 or 4)
Cable break
The four input signals from the incremental transducer are compared
with each other; if a fault is recognised in one or more cables, then a
memory is set and the KB-IG light diode is illuminated.
When the incremental transducer and the reciever module are supplied
via a separated potential spply or when a frequency and direction
signal is applied, then cable break monitoring is not possible. In this
case the resistors R18 to R21 and jumper JP have to be removed.
Over speed detection
For speed monitoring the input impulse trains are individually
monitored before conversion, so that should one channel fail over
speed can be recognised in the other channel.
The output signal of this circuit is combined with the "nmax" signal of
the VT 12000, the analogue signal is monitored.

RE 29 761/12.02

If over speed is detected then a memory is set and the "nmax" light
diode is illuminated.
The limiting frequency for the monitoring response is set via the R50
and R51 resistors; the value is given by
1
R

flimit
where flimit = switch off frequency without multi-evaluation in kHz.
Interconnection circuitry
Via 6 opto decoupled inputs it is possible to apply further monitoring
signals, these are individually stored and displayed via light diodes
on the front plate, where five of these inputs are pre-designated for
the "nmax", "amax", "ndiff", " diff" and H1 of the VT 12000 monitoring
outputs, the signals "ndiff" and " diff" must be delayed within the
VT 12000.
All of the monitoring signals are connected with each other so that
when a fault occurs the output from the card is switched off. This
fault condition is stored until it is reset either via the enable/reset
input or via the reset button on the front plate.
The opto-decoupled enable/reset input, e.g. for a higher control,
directly switches the output. When switching off this input, e.g. by
pressing the reset button on the front plate, the output is switched
off and the stored fault conditions are deleted.
These input signals can be inverted via the SW1 DIP switches. They
can thereby be applied as "active high"- or as "active low" signals.
The output from these interconnected signals switches the enable
light diode as well as a TTL, an inverse TTL, a + 15 V output (e.g. for
the control of RK4, opto coupler), an opto coupler and a power
transistor with protective circuit (varistor), with which the 24 V/1.2 A
required for a logic valve can be directly switched.
When used with a higher control (e.g. PLC) the evaluation of the VT
12000 monitor outputs can be carried within the control.
The internal monitoring signals "cable break" and "over frequency"
are furthermore linked, saved and can be deleted via the enable/
reset input.

2/6

VTS 0102

655

Technical data (for applications outside these parameters, please consult us!)
General
Supply voltage

UL:

+24 V, smoothed

UM:

15 V, controlled; approx. + 100 mA, 50 mA

UTTL:
Urecommend.:

+ 5 V, controlled; approx. 200 mA


+ 5 V, controlled; approx. 50 mA
(with potentional separated transducers UEmpf can be generated
via the internal voltage controller with impulse supply; input
voltage 8 to 28 V)

Input voltage
Opto coupler:

12 to 24 V

Terminal strip:

64-pin to DIN 41 612 form C

Space requirements

Conductor side:
Component side:

Permissible ambient temperature


Weight

t:
m:

1 TE (5.08 mm)
3 TE
0 to 50 C
0.25 kg

04

VTS 0102

3/6

RE 20 761/12.02

P
S
L
P
C
S

RE 29 761/12.02

4/6

Enable / reset

Emergency OFF

Controller enable
switching
etc.

VTS 0102 S1X/FUW1

VT 12000

+
act.

U
f

aact.

Monitoring

Monitoring
+
signal memory

(optional)

PID

+com.
PD

U
I

p0

p0

656

Signal flow plan

VTS 0102

11a

10a

VTS 0102

5/6

H1

diff

amax

ndiff

nmax

Urec.
GND

Enable / reset

Outputs from
VT 12000

Supply
Receiver

25c

24c

29c

28c

31c

30c

27c

26c

13c

12c

7c

6c

9c

8c

8a

6a

4a

2a

4c

2c

Frequency external 12a

Direction external

Switch point
matching

P8

P7

P6

P5

SW 1-3

&

B3

SW 1-2

SW 1-5

SW 2

Set

SW 1-1

Set
Reset

Reset

Set
Reset

SW 1-6

Reset

Set

SW 1-7

Reset

Set

Reset

Set

Set
Reset

Reset

3
2

SW 1-8

SW 1-4

P4

Cable break
monitoring

Sensitivity

H1

KB - IG

Frequency monitoring

Frequency monitoring

Evaluation

Direction
Direction
1-fold
2-fold
4-fold

&

B4

&

1
2
3
B4

B2
2

Gain

5V voltage
regulator

+ 15 V

8 to 28 V
Input
GND
5 V output

10c

+ 24 V
supply
24V switched
output
14a / 11c

(inverted)

Enable + 15 V
28a Enable

24a

27a

26a

10 V

Measuring
points

Enable

20c
22a

18ac
+5V

16ac

14c

21c

22c

23c

9a

7a

5c

15 V

GND

3c
5a

3a

1c

1a

30a Actual value

Zero point

P3

Symmetry

P9

P1

P2

Enable

P10

Direction (TTL)
train (TTL)

32a Impule

31a

657

Block circuit diagram and connection allocation VTS 0102 S1X/FUW1

04

RE 20 761/12.02

658

Unit dimensions

(Dimensions in mm)

89

KB-IG

100

Enable
Freigabe

128

H1
a max
nmax

15

ndiff
diff

NP
f/U

2
7

165
184

nist
act.

14

VTS
0102

20

Reset

FUW1

RE 29 761/12.02

6/6

VTS 0102

659
RE 00112-04

Hydraulics Bosch Rexroth AG

Electro-hydraulic systems

Type

Series

Data
sheet no.

Closed-loop pressure and flow control system

SYDFE1

2X

30024

661

Pressure and flow control system

SYDFEC

2X

30027

673

Pressure and flow closed loop system

SYDFEE

2X

30030

687

Pressure-flow closed loop control system

SYHDFEE

1X

30035

701

Pump pre-load valve for the SYDFE closed loop control system

SYDZ0001

1X

29255

713

3/3 proportional directional valves, direct operated, with electricalposition feedback as pilot valves for the SYDFE. control system

VT-DFP

2X

29016

717

Digital controller amplifier for operating axial piston pumps


of type A4VS... with HS4 control

VT-VPCD

1X

30028

729

External control electronics for the DFE1 control of A10VSO axial


piston pumps , analogue amplifier, configurable

VT5041

2X

30241

741

Designation

Page

Closed loop control systems for hydraulic pumps

Accessories

01

03

04

05

05

660
Bosch Rexroth AG

Hydraulics

RE 00112-04

661

RE 30024/11.03
Replaces: 10.02

Closed-loop pressure and


flow control system

1/12

Type SYDFE1

Series 2X
H6707

Table of contents
Contents

Features
1

The DFE1 control system is used for the electrohydraulic pressure and flow control of a variable displacement axial piston pump

2, 3

The SYDFE1 control system consists of the following components:

A10VSO axial piston pump with built-on VT-DFP-2X proportional valve as pilot valve, including inductive position transducers for the acquisition of swivel angle and valve displacement

Page

Features
Ordering code
Function, section
Schematic diagram
Technical data
Characteristic curves

5, 6
7
8, 9

HM 12 or HM 13 pressure transducer for the acquisition of the


system pressure (optional)

Unit dimensions

10

Nameplate lettering (example)

10

VT 5041-2X analogue amplifier for realising all the electrical


functions that are required by the DFE1 control system

Plug-in connectors

11

Pump preload valve (optional)


Pump combinations possible

Further information about this system:


Component description of A10VSO pump

RE 92712 for size 18


RE 92711 for sizes 28 to 140

Component description of VT 5041-2X analogue amplifier

RE 30241

Component description of HM 12-1X / HM 13-1X pressure transducers

RE 29933

Component description of VT-DFP.-2X/ pilot valve

RE 29016

Component description of SYDZ 0001-1X pump preload valve

RE 29255

In addition, the following information is available about the SYDFE1 system:


Sales information (engineering aids)

RE 30030-01-V

05

662
2/12

Bosch Rexroth AG

Industrial Hydraulics

RE 30024/11.03

SYDFE1

Ordering code
SYDFE1 2X

12

1)

Further details
in clear text
Preload valve
1 = Pressure limitation
200 bar
2 = Pressure limitation
250 bar
3 = Pressure limitation
300 bar
X=
Without
preload valve

Single pump
Pump
combination 2)

Series 20 to 29
= 2X
(20 to 29: unchanged installation
and connection dimensions)
A10VSO pump
Size 18
Size 28
Size 45
Size 71
Size 100
Size 140

= 018
= 028
= 045
= 071
= 100
= 140

Direction of rotation
Clockwise (preferred types
for through-drive pumps)
Anti-clockwise

Pressure transducer
HM 12 (4 to 20 mA)
C = Measuring range 315 bar
HM 13 (0 to 10 V)
G Measuring range 315 bar
=
X=
Without pressure
transducer

=R
=L

Hydraulic fluid
Mineral oil to DIN 51 524 (HL / HLP)

=P

Electronic assembly,
VT 5041-2X with switch-able
actual pressure value signal
(from series 25)
P=
4-20 mA /
0-10 V /
0-5 V /
1-10 V
X=
Without amplifier

Shaft end
( = Preferred types for through-drive pumps)

Size

18

28

3)

4)

3/4

5)

7/8

45

71

100

140

22 25 32 40 45

Connection flange (
Size

18

ISO 2-hole

ISO 4-hole

SAE 2-hole

1 1/2 1 3/4

1 1 1/4

=P
=S
=R

Additional function, VT 5041-2X with


power limiter and swivel angle indicator
X=
Without amplifier
1 = Amplifier without additional function
3=
Amplifier with additional function

= available)
28

45

71

100 140

=B

Connection for service lines


Pressure port B
SAE on opposite sides
Pressure port S
Mounting thread, metric
Through-drive (see table on page 3)
Without through-drive
Through-drive without hub for mounting:
(any built-on pumps with SAE splined shaft profile )
Centring (mm)

Built-on pump

82.55
100
125
180
101.6
127

A10VSO18
A10VSO28/45
A10VSO71/100
A10VSO140
Gear pump
Gear pump

=A
=C
0=
= 12

Valve, installation orientation


Plug-in connector installed radially
to pump axis

A=
= N00

= KC1 6)
= KD3 6)
= KD5 6)
= KD7 6)
= KC3 6)
= KC5 6)

For single pumps, the hub must be ordered separately, if required.


For double pumps, the hub is included in the scope of supply.

0000 =
0479 =
0487 =

Valve, spool variant


Basic pump version
Standard (internal pilot oil supply)
External supply (sizes 18 100)
External supply (size 140)

1)

See order example at the top of page 3

2)

See order example at the top of page 3

3)

Cylindrical with keyed shaft DIN 6885

4)

Splined shaft profile SAE

5)

Splined shaft profile SAE (higher trough-drive torque)

6)

Through-drive is fitted with an operationally safe blind


cover

663
RE 30024/11.03

3/12

Industrial Hydraulics Bosch Rexroth AG

SYDFE1

Ordering code
Order example
1) Order example of single pump
SYDFE1-2X/100R-PSA12N00-0479-A0X0XCX
2)

Order example of pump combination


Both type designations must be connected with + (material number of 1st pump + material number of 2nd pump)
SY2DFE1-2X/100-100/

R900709794

R900709794

SY2DFE1-2X/100-100/ SYDFE1-2X/100R-PSA12KD5-0000-A010PCX + SYDFE1-2X/100R-PSA12KD5-0000-A010PCX


Double
pump
Size of front pump
Size of rear pump
Material number of front pump
(or details in clear text, if material number is not known)
Material number of rear pump
(or details in clear text, if material number is not known)

Preferred types
Through-drive pumps for pump combinations

Single pumps
Type

Material no.

Type

Material no.

SYDFE1-2X/018R-PSC12N00-0000-A010PCX

R900783410

SYDFE1-2X/028R-PRA12KD3-0000-A010PCX

R900709782

SYDFE1-2X/028R-PPA12N00-0000-A010PCX

R900708517

SYDFE1-2X/045R-PRA12KD3-0000-A010PCX

R900709786

SYDFE1-2X/045R-PPA12N00-0000-A010PCX

R900708518

SYDFE1-2X/071R-PRA12KD5-0000-A010PCX

R900709792

SYDFE1-2X/071R-PPA12N00-0000-A010PCX

R900708519

SYDFE1-2X/100R-PSA12KD5-0000-A010PCX

R900709794

SYDFE1-2X/100R-PPA12N00-0000-A010PCX

R900708520

SYDFE1-2X/140R-PSB12KD7-0000-A010PCX

R900709795

SYDFE1-2X/140R-PPB12N00-0000-A010PCX

R900708521

Size
Through-drive (

= available)

18

28 45

71

100

Without through-drive

140
N00

With through-drive for building on an axial piston unit, a gear pump or a radial piston pump
Mounting flange

Shaft/coupling (separate order)

for mounting:

ISO 100, 2-hole

Splined shaft 7/8 22-4 (SAE B)

A10VSO 28 (shaft S or R)

ISO 100, 2-hole

Splined shaft1 25-4 (SAE B-B)

A10VSO 45 (shaft S or R)

ISO 125, 2-hole

Splined shaft 1 1/4 32-4 (SAE C)

A10VSO 71 (shaft S or R)

ISO 125, 2-hole

Splined shaft 1 1/2 38-4 (SAE C-C) A10VSO 100 (shaft S)

ISO 180, 4-hole

Splined shaft 1 3/4 44-4 (SAE D)

82-2 (SAE A, 2-hole) Splined shaft 5/8 16-4 (SAE A)

A10VSO 140 (shaft S)

KD3

KD3
KD5
KD5

1PF2G2, PGF2

KD7
KC1

82-2 (SAE A, 2-hole) Splined shaft 3/4 19-4 (SAE A-B)

A10VSO 10, 18 (shaft S)

101-2 (SAE B)

Splined shaft 7/8 22-4 (SAE B)

A10VO 28 (shaft S), PGF3

KC3

101-2 (SAE B)

Splined shaft 1 25-4 (SAE B-B)

A10VO 45 (shaft S), PGH4

KC3

127-2 (SAE C)

Splined shaft 1 1/4 32-4 (SAE C)

A10VO 71 (shaft S)

127-2 (SAE C)

Splined shaft 1 1/2 38-4 (SAE C-C) A10VO 100 (shaft S), PGH5

152-4 (SAE D)

Splined shaft 1 3/4 44-4 (SAE D)

A10VO 140 (shaft S)

KC1

KC5
KC5

KC6

05

664
4/12

Bosch Rexroth AG

Industrial Hydraulics

SYDFE1

RE 30024/11.03

Function, section
The pressure and swivel angle of A10VSODFE1 variable
displacement pumps are controlled via an electrically controlled proportional valve (2). The proportional valve determines
the position of swashplate (1) via actuating piston (4). The
displaced flow is proportional to the position of the swashplate. The opposing piston (3) that is preloaded by spring (5) is
continuously pressurised with pump pressure.
When the pump is not rotating and the control system is
depressurised, the swashplate is held at position + 100 % by
spring (5). With a driven pump and a de-energised proportional
solenoid (8) the system swivels to zero stroke pressure, since
valve spool (9) is pushed by spring (10) to the basic position
and thus pump pressure p is applied to actuating piston (4) via
valve port A. A balance between pump pressure at the actuating piston and spring force (5) is achieved at 8 to 12 bar. The
system returns to this basic position (= zero stroke operation)
when the control electronics is inactive (e.g. controller enable
missing).
The VT 5041-2X controller card that belongs to the system
controls the proportional valve. This controller card processes
all the closed-loop control signals that are required for operating the A10VSODFE1 variable displacement pump.
The VT 5041-2X analogue amplifier is designed as plug-in card
in Euro-format. As a standard, it is provided with a command
value input each for pressure and swivel angle (input for
power command value optional). The actual pressure value is
acquired by a pressure transducer. Position transducer (7) on
the pump acquires the actual swivel angle value. The acquired
actual values are processed in the amplifier and compared with
the selected command values. The minimum value generator ensures that always the controller that is assigned to the
relevant working point is automatically active. Here, a system

variable (pressure, swivel angle or [optional] power) is corrected exactly while the other two system variables are below the
given command values. The output signal of the minimum value
generator becomes the command value for the valve control
loop.
The actual value of the valve spool position is acquired by
means of inductive position transducer (6). The output value
of the valve position controller determines the current through
proportional solenoid (8) via the amplifier output stage. As
soon as the working point is reached is control spool (9) of the
proportional valve held in the central position.
If the higher-level controllers demand an increase in the swivel
angle (increase in flow), valve spool (9) must be moved from
the central position (connection of actuating piston (4) A T)
until the swivel angle reaches the required value. The
movement of the valve spool against the force of spring (10) is
achieved by a corresponding increase in the electrical current
through proportional solenoid (8).
A reduction of the swivel angle (reduction of flow) is achieved
through the connection of the actuating piston (4) from P A.
Control system supply
There are three possibilities of supplying the hydraulic control
system of the pump with pilot oil:
1. Internal, without preload valve (only possible with system
pressures > 20 bar)
2. Internal, with preload valve (system pressure 0 100%)
3. External supply via shuttle valve automatic changeover
internal / external through shuttle valve sandwich plate)
(observe sales information RE 30030-01-V!)

6
P A T
1
100%

4
Zero stroke
operation

+ 100%

Type SYDFE1-2X/071-PPA12N00-

10

665
RE 30024/11.03

Industrial Hydraulics Bosch Rexroth AG

SYDFE1

5/12

Schematic diagram: Control system with internal supply (self-supply)

Actuator

(qV; p)
The prescribed maximum
pressure relief can be
ignored when a preload
valve is used.

Pressure transducer

P
U/I

MP1 Preload valve (optional)

P1

Analogue
amplifier

VT5041-2X
A

(Power command value


0 to 10 V) 1)
Flow command value
0 ( 10 V) to + 10 V

20 bar

Pressure command value


0 to 10 V

P
T
P

Enable
Error

PP
Bleed
point

s
U

P B

A
s

Pump

1)

L1

Optional

05

666
6/12

Bosch Rexroth AG

Industrial Hydraulics

SYDFE1

RE 30024/11.03

Schematic diagram: Control system with external supply


Actuator

(qV; p)
p
3)

Pressure transducer

P1

max

P
U/I

Analogue
amplifier
Pressure command value 0 to 10 V

VT5041-2X

(Power command value 0 to 10 V) 1)


Flow command value
0 ( 10 V) to + 10 V
Enable
Error

A
U

P
20 bar

4)

P B
s

Z (External pilot

oil pressure)

M
P
2)

0,2 bar

Pump

L1

1)

Optional

3)

2)

The use of a pressure relief and anti-caviation valve (check


valve with 0.2 bar spring) is essential in order to prevent
cavitation in the case of an error.

Maximum pressure relief function must be provided by the


customer!

4)

Observe upper limit for external pilot oil pressure!


(cf. RE 30030-01-V), recommendation: 20 bar absolute.

Caution!
In the case of an externally supplied control system, the function that swivels the pump to zero stroke when the output
stage of the controller card is de-energised is inactive.
In the case of a de-energised output stage of the controller
card, the external pressure pushes the swashplate of the
controller pump to the negative limit stop (100 % flow is fed
from the system to the tank).
When an error is detected, the output stage switches off and
the external supply causes the pump to swivel towards the
negative limit stop. When an error message is present, it is

essential that the machine control responds (e.g. drive motor


of the pump must be switched off, external supply of the
actuating system must be interrupted).
The command values for pressure and flow must always be
greater than zero (pcomm 3 bar, comm 5 %), since, due to
drift or incorrect settings, there is no exact zero pressure or
zero swivel angle. Under unfavourable conditions, smaller
command values can lead to cavitation.
The pressure command value must not be less than 10 bar
for more than 10 minutes (lubrication).

667
RE 30024/11.03

7/12

Industrial Hydraulics Bosch Rexroth AG

SYDFE1

Technical data (for applications outside these parameters, please consult us!)
General
Ambient temperature range for the pump

20 to + 70 C

Ambient temperature range for the controller card

0 to 50 C

Drive speed

See RE 92711 (sizes 28 140) and RE 92712 (size 18)

Size

Size

18

28

45

71

100

140

kg

14

17

23

35

47

62

Additionally, preload valve

kg

3.3

3.3

3.3

6.3

6.3

6.3

Additionally, with external control system supply

kg

Weight Pump without through-drive, incl. pilot valve

Hydraulic
Max. permissible operating pressure

pmax

250 bar1) (280 bar after consultation)

Actuating pressure

pmin

20 bar

pmax with external pilot oil supply

30 bar

Hydraulic fluid temperature range

20 to + 70 C

Hydraulic fluid

Mineral oil (HL, HLP) to DIN 51 524

Contamination with solid particles

Max. permissible degree of contamination of the hydraulic fluid according to ISO 4406 class 18/16/13 (for particle sizes 2/5/15 m) 2)

Electrical 3)
Power consumption of the cotroller card

Type of protection of the pump to DIN 40 050


1)

For supplementary information, see sales information


(engineering aids RE 30030-01-V)

2)

The cleanliness classes specified for the components must


be complied with in hydraulic systems. Effective filtration prevents malfunction and at the same time increases the service
life of components.
For the selection of filters, see data sheets RE 50070,
RE 50076 and RE 50081.

3)

For additional information, see data sheet RE 30241

35 W (UB = 24 V)
IP 65 with plug-in connector mounted and locked
Note: For details on Environment simulation tests
in the fields of EMC (electromagnetic compatibility),
climate and mechanical stress, see RE 30024-U
(declaration on environmental compatibility).

Control loop quality SYDFE1 (the specified values are valid only when system-related components are used in accordance with the
Closed-loop swivel angle control

Closed-loop pressure control 4)

Linearity tolerance

1.0 %

1.5 %

Temperature drift

0.5 %/10 K

0.5 %/10 K

Hysteresis

0.2 %

0.2 %

Repeatability

0.2 %

0.2 %

4)

Without consideration of pump pulsation

05

668
8/12

Bosch Rexroth AG

Industrial Hydraulics

SYDFE1

RE 30024/11.03

Transient function at pressure command value step change, SYDFE1 with 360 spool (version A)
The curve shapes and control times given can only be achieved with an optimized pressure controller.
140

140

pcomm

120

Puressure p in bar

Puressure p in bar

120

T 95% in ms with hydraulic


fluid volume being connected
(lines and actuators)

100
80
60

pact

40
20

pact
100
80

pcomm

<5L

150 ms

5 10 L

200 ms

15 25 L

250 ms

60

At pressures up to 40 bar
the response time values
are higher.

40
20

0
T95%

T95%

Control time

Control time

Transient function with swivel angle command value step-change with 360 spool (version

100

Actual swivel angle value in %

Actual swivel angle value in %

Sizes 18, 28, 45, 71 p = 20 bar

80
60
40
20
0

30

60

90

100
80
60
40
20
0

120

30

Time in ms

100
80
60
40
20
0

90

120

90

120

p = 50 bar
Actual swivel angle value in %

Actual swivel angle value in %

Sizes 18, 28, 45, 71

60
Time in ms

30

60
Time in ms

90

120

100
80
60
40
20
0

30

60
Time in ms

669
RE 30024/11.03

Industrial Hydraulics Bosch Rexroth AG

SYDFE1

9/12

Transient function with swivel angle command value step-change with 360 spool (version

100

Actual swivel angle value in %

Actual swivel angle value in %

Size 100 p = 50 bar

80
60
40
20
0

30

60

90

100
80
60
40
20

120

30

Time in ms

60

90

120

90

120

Time in ms

100

Actual swivel angle value in %

Actual swivel angle value in %

Size 140 p = 50 bar

80
60
40
20
0

30

60
Time in ms

90

120

100
80
60
40
20
0

30

60
Time in ms

05

670
10/12

Bosch Rexroth AG

Industrial Hydraulics

SYDFE1

RE 30024/11.03

Unit dimensions of SYDFE1 (dimensions in mm)


Preload valve (optional)

Place of installation of
pilot valve with clockwise
direction of rotation

A6 II

Sizes 18 to 140
(shaft version S;
without through-drive N00)

A2

A7 III

A4
A5

A6 I

A1

A6

S
(Representation of size 71)

Place of
installation of
pilot valve with
anti-clockwise
direction of
rotation

Z
A3
15

A7 I

A7 II

Space required to remove


plug-in connector
Pilot oil port Z
Size

A1

A2

A3

A4

A5

A6

A6 I

A6 II

A7 I

A7 II

A7III

18

98

107

161

158

63

178

63

115

196

125

100

28

106

107

171

158

63

195

80

115

206

135

115

45

112

107

181

158

63

205

90

115

216

145

125

71

124

107

195

158

63

254

104

150

230

159

150

100

129

107

200

158

63

247

100

147

235

164

150

140

140

107

213

143

78

257

110

147

248

182

150

Example of nameplate for a pump combination SY2DFE1


The nameplate shown is that of the built on size-45 pump!

Line 1
Serial no. (referred to manufacturing batch)

Line 3
Production no.

Line 5
Fabrication no.

0000001
SY2DFE1-2X/071-045/+R900945317
20928065
Baujahr A004
Mat. Nr *R900945336*
MINERALL
Fabr. Nr 73939649
Drehrichtung
MADE .................

R900215052

Line 4
Material no. of the pump
combination (for single pump
identification, see line 2)

Line 2
Clear text of pump combination
with indication of the material no.
(= technical version) of the builton pump of size 45

Year of construction

Direction of rotation
Production location

For queries regarding the pump combination, state the material number (line 4) and the fabrication number
(line 5).

671
RE 30024/11.03

SYDFE1

Industrial Hydraulics Bosch Rexroth AG

11/12

Plug-in connectors (included in the scope of supply)


Plug-in connector for solenoid plug (material no. R900008909)
Plug-in connector for valve position transducer (material no. R900023126)
Plug-in connector for pump position transducer (material no. R900013674)

05

672
12/12

Bosch Rexroth AG

Industrial Hydraulics

SYDFE1

RE 30024/11.03

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

2003 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, duplicated or circulated using electronic systems, in any form or
by any means, without the prior written authorisation of Bosch Rexroth AG.
In the event of contravention of the above provisions, the contravening party
is obliged to pay compensation.
The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information.The details stated do not release you
from the responsibility for carrying out your own assessment and verification. It must be remembered that our products are subject to a natural
process of wear and ageing.

673

Pressure and flow control system

RE 30027/06.04
Replaces: 05.02

1/14

Type SYDFEC

Component series 2X

H6928/01

Table of contents
Contents
Features
Ordering code
Function, section
Schematic diagram
Technical data
Electrical connection
Block circuit diagram
Scope of functions, communication via CAN bus,
closed control loop quality
Characteristic curves
Unit dimensions
Nameplate lettering (example)
Engineering notes

Features
Page
1
2 and 3
4
5 and 6
7
8
9
10
11 and 12
12
13
13

The DFEC control is used for the electrohydraulic control of


pressure and swivel angle of a variable displacement axial piston
pump.
The SYDFEC.. closed-loop control system consists of the following components:
A10VSO axial piston pump with built-on VT-DFPC-2X/..
proportional valve as pilot valve
The VT-DFPC..-2X/.. valve with integrated digital open and
closed-loop control electronics with CANopen interface integrates the entire control functionality for the DFEC system
The swivel angle is acquired by a VT-SWA-1-1X rotary angle
sensor based on a Hall sensor
Pump pre-load valve (optional)
Pump combinations possible
The HM16 pressure transducer (optional) for installation in the
pump or the pre-load valve for direct connection to the control
electronics. This provides a complete plug-in system.

Further information about this system:


Component description of A10VSO pump
RE 92712 for size 18, RE 92711 for sizes 28 to 140
Component description of VT-SWA-1-1X rotary angle sensor
RE 30268
Component description of HM 12-1X / HM 13-1X pressure transducer
RE 29933
Component description of HM16-1X pressure transducer
RE 30266
Component description of VT-DFPE-2X/ pilot valve
RE 29016
Component description of SYDZ 0001-1X pump pre-load valve
RE 29255
In addition, the following information about the SYDFEE system can be ordered:
Sales information (engineering aids)
RE 30030-01-V
Description of the CANopen interface
RE 30027-Z
Engineering notes and commissioning instructions
RE 30027-B

05

674
2/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC RE 30 027/06.04

Ordering code
SYDFEC 2X

12

1)

Further
details
in clear text
Pre-load valve
Pressure limitation
1=
200 bar
2=
250 bar
3=
300 bar
X = W/o pre-load valve
Pressure transducer
C=
HM 12 (4 to 20 mA)
measuring range 315 bar
G=
HM 13 (0 to 10 V)
measuring range 315 bar
L=
HM 16 (0.5 to 5 V)
measuring range 315 bar 7)
with 0.5 m connecting cable
and M12 cable plug
X = W/o pressure transducer
Actual pressure value input

Single pump
Pump
combination 2)

Series 20 to 29
= 2X
(20 to 29: unchanged installation and connection dimensions)
A10VSO pump
Size 18
Size 28
Size 45
Size 71
Size 100
Size 140

= 018
= 028
= 045
= 071
= 100
= 140

Direction of rotation
Clockwise (preferred types for
through-drive pumps)
=R
Anti-clockwise
=L
Hydraulic fluid
Mineral oil to DIN 51 524 (HL / HLP) = P
Shaft end
( = preferred types for through-drive pumps)

Size 18
3)

4)

3/4

5)

28

45

71

100 140

22 25 32 40 45 = P

1 1/2 1 3/4 = S

7/8 1 1 1/4

Connection flange (
Size

18

ISO 2-hole

ISO 4-hole

=R

0=

= available)

28

45

71

100 140

A=
=A

Centring (mm)

Built-on pump

82.55
100
125
180
101.6
127

A10VSO18
A10VSO28/45
A10VSO71/100
A10VSO140
Gear pump
Gear pump

Current input 4 20 mA

V=

Voltage input 0 10 V

D=

Voltage input 0 5 V

E=
F=

Voltage input 1 10 V
Voltage input 0.5 5 V 8)

Electronics assembly, optional


Baud rate 500 kBit/s
Additional functions
Standard

Valve, installation orientation, integrated electronics


0=
Radial to pump axis
2=
Folded by 90 towards the subplate

=B

SAE 2-hole

=C
Ports for service lines
Pressure port B
SAE laterally on the opposite side = 12
Suction port S
Mounting thread, metric
Through-drive (see table on page 3)
Without through-drive
Through-drive without hub for mounting:
(all built-on pumps with SAE splined shaft
profile)

C=

A=
0000 =
0479 =
0487 =

= N00

Valve, spool version


Version of the basic pump
Standard (internal pilot oil supply)
External supply (sizes 18 100)
External supply (sizes 140)

Accessories:
For suitable plug-in connectors (separate order), see page 12
= KC1 6)
= KD3 6)
= KD5 6)
= KD7 6)
= KC3 6)
= KC5 6)

In the case of single pumps the hub must be ordered separately, if required.
In the case of double pumps the hub is included in the
scope of supply.

1)
2)
3)
4)
5)
6)
7)
8)

See order example on page 3, top


See order example on page 3, top
Cylindrical with keyed shaft to DIN 6885
Splined shaft profile SAE
Splined shaft profile SAE (higher through-drive torque)
Through-drive is provided with end cover for operational safety
For direct connection to integrated electronics version
actual pressure value input F
Connection by means of M12 component socket

675
RE 30 027/06.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEC

3/14

Ordering code
Order example
1) Order example of single pump
SYDFEC-2X/100R-PPA12N00-0000-A0A0FLX
2)

Order example of pump combination


Both type designations must be connected by + (material number of 1st pump + material number of 2nd pump)
SY2DFEC-2X/100-100/
R900709799
+
R900709799
SY2DFEC-2X/100-100/ SYDFEC-2X/100R-PSA12KD5-0000-A0A0FLX + SYDFEC-2X/100R-PSA12KD5-0000-A0A0FLX

Double
pump
Size of front
pump
Size of rear pump
Material number of front pump (or indication in clear
text, if material number is not known)
Material number of rear pump (or indication in clear text, if material number is not known))
Preferred types
Single pumps

Through-drive pumps for pump combination

Type

Material no.

Type

Material no.

SYDFEC-2X/018R-PSC12N00-0000-A0A0FLX R900731028

SYDFEC-2X/028R-PRA12KD3-0000-A0A0FLX R900709796

SYDFEC-2X/028R-PPA12N00-0000-A0A0FLX R900721765

SYDFEC-2X/045R-PRA12KD3-0000-A0A0FLX R900709797

SYDFEC-2X/045R-PPA12N00-0000-A0A0FLX R900731026

SYDFEC-2X/071R-PRA12KD5-0000-A0A0FLX R900709798

SYDFEC-2X/071R-PPA12N00-0000-A0A0FLX R900731027

SYDFEC-2X/100R-PSA12KD5-0000-A0A0FLX R900709799

SYDFEC-2X/100R-PPA12N00-0000-A0A0FLX R900708502

SYDFEC-2X/140R-PSB12KD7-0000-A0A0FLX R900709800

SYDFEC-2X/140R-PPB12N00-0000-A0A0FLX R900725946

Size
Through-drive (

= available)

18

28 45

71

100

Without through-drive

140
N00

With through-drive for mounting an axial piston unit, a gear pump or a radial piston pump
Mounting flange

Shaft/coupling (separate order)

for mounting:

ISO 100, 2-hole

Splined shaft 7/8 22-4 (SAE B)

A10VSO 28 (shaft S or R)

ISO 100, 2-hole

Splined shaft 1 25-4 (SAE B-B)

A10VSO 45 (shaft S or R)

ISO 125, 2-hole

Splined shaft 1 1/4 32-4 (SAE C)

A10VSO 71 (shaft S or R)

KD3
KD3

KD5

ISO 125, 2-hole

Splined shaft 1 1/2 38-4 (SAE C-C) A10VSO 100 (shaft S)

ISO 180, 4-hole

Splined shaft 1 3/4 44-4 (SAE D)

A10VSO 140 (shaft S)

KD5

KD7

82-2 (SAE A, 2-hole) Splined shaft 5/8 16-4 (SAE A)

1PF2G2, PGF2

KC1

82-2 (SAE A, 2-hole) Splined shaft 3/4 19-4 (SAE A-B)

A10VSO 10, 18 (shaft S)

KC1

101-2 (SAE B)

Splined shaft 7/8 22-4 (SAE B)

A10VO 28 (shaft S), PGF3

KC3

101-2 (SAE B)

Splined shaft 1 25-4 (SAE B-B)

A10VO 45 (shaft S), PGH4

KC3

127-2 (SAE C)

Splined shaft 1 1/4 32-4 (SAE C)

A10VO 71 (shaft S)

127-2 (SAE C)

Splined shaft 1 1/2 38-4 (SAE C-C)

A10VO 100 (shaft S), PGH5

KC5

KC5

05

676
4/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC RE 30 027/06.04

Function, section
The pressure and swivel angle control of the A10VSO variable
displacement pump within the SYDFEC system is provided by
an electrically controlled proportional valve (2). The proportional
valve determines the position of the swashplate (1) by means of
the actuating piston (4). The displaced oil flow is proportional
to the position of the swashplate. The counter-piston (3) that
is pre-loaded by a spring (5) is continuously pressurised with
pump pressure.
When the pump is not rotating and the actuating system is
depressurised, the swashplate is held by a spring (5) in position + 100 %. When the pump is powered and the proportional
solenoid (8) is de-energised, the system swivels to zero stroke
pressure, since a spring (10) pushes the valve spool (9) to the
neutral position and pump pressure p is therefore applied to the
actuating piston (4) via valve port A. At 8 to 12 bar, a balance
is reached between the pump pressure at the actuating piston
and the spring force (5). This neutral position (= zero stroke
operation) is taken, when, for example, the valve electronics is
de-energised.

A minimum value generator ensures that only that controller is


active which is assigned to the desired working point. Here, one
system variable (pressure, swivel angle or power) is exactly corrected, the other two variables are below the given command
values. The output signal of the minimum value generator becomes the command value for the closed valve control loop.
The actual value of the valve spool position is acquired by an inductive position transducer (6). The output value of the valve position controller determines the current through the proportional
valve (8) via the amplifier output stage. As soon as the working
point is reached, the control spool (9) of the proportional valve
is held in its central position.
If the higher-level controllers demand an increase in the swivel
angle (increase in flow), the valve spool (9) must be shifted from
the central position (connection of actuating piston (4) A T)
until the swivel angle has reached the required value. Shifting
the valve spool against the force of the spring (10) is achieved
by increasing the electric current through the proportional solenoid (8).

The proportional valve is controlled by digital electronics (11)


integrated in the valve. This closed-loop control electronics
processes all of the control signals required for operating the
A10VSO variable displacement pump under closed-loop pressure and flow control.

The swivel angle is reduced (reduction in flow) by opening the


connection of the actuating piston (4) from P > A.

The control electronics receives the command values for pressure and swivel angle as well as the power limit via the CAN bus
(14). Optionally, the command values for pressure and swivel angle can each be fed forward via an analogue input or be changed
over via 2 switching inputs. The HM16 pressure transducer is to
be mounted to port P of the pump or, if an SYDZ pre-load valve
is used, to port MP1, and connected to the M12 component
socket (13). Alternatively, an external pressure transducer can
be connected via the central plug (12). A position transducer
with integrated electronics (7) on the pump acquires the actual
swivel angle value. The acquired actual values are processed in
the amplifier and compared with the selected command values.

There are three possibilities of supplying the hydraulic control


system of the pump with pilot oil:

Actuating system supply

1. Internal, without pre-load valve (only possible with system


pressures > 20 bar)
2. Internal, with pre-load valve (system pressure 0 100%)
3. External supply via shuttle valve automatic change-over
internal / external through shuttle valve sandwich plate
(observe engineering notes!)

8
10
1
100 %

Zero
stroke
operation

Type SYDFEC-2X/-PP

+ 100 %

P A T

9
2
12
11
14 CAN bus connection
HM 16 connection
13

677
RE 30 027/06.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEC

5/14

Schematic diagram: Actuating system supplied internally (inlet supply)


Consumer

(qV; p) The prescribed maximum


pressure relief feature is not
required when a pre-load
valve is used.

P1

MP1 Pre-load valve (optional)

P1

20 bar

P
U/I

Pressure transducer

Optional 1)

P
Bleed point

PP

VT-DFPC-2X/pilot valve
CAN bus

Analogue signals (opt.)


Comm. value call-ups(opt.)

Pressure
command value
Flow command
value

U
Error

B P

A
U

Pump

L1

1) If an HM16 pressure transducer is used:


Installation in P (pump) or MP1 (pre-load valve) in conjunction with electronics version actual pressure value input F
If an external pressure transducer is used:
Installation in the P1 line (preferably in the vicinity of the consumer) and electrical connection using the central plug

05

678
6/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC RE 30 027/06.04

Schematic diagram: Actuating system supplied externally


Consumer

(qV; p)

p
2)

Optional 3)
max

P1
P

P
U/I Pressure transducer

CAN-Bus

Pressure
command value
Analogue signals (opt.) Flow command
value
Comm. value call-ups(opt.)

VT-DFPC-2X/ pilot valve

Error

s
U

A
P
B P

20 bar

Z
U

M
P
1)

0,2 bar
S

Pump

L1

1)

The use of an anti-cavitation valve (check valve with 0.2 bar spring) is absolutely essential, in order to prevent cavitation in the
event of a fault.

2)

The maximum pressure relief feature must be provided by the customer!

3)

Pressure transducer

Mounting option

Remark

HM16

Only in conjunction with electronics version actual pressure value input F

HM12 / HM13

P1

Preferably in the vicinity of the consumer

Caution!
With an externally supplied actuating system, the feature that
swivels the pump to zero stroke in the case of de-energised
control electronics is inactive.

control must in any case react (e.g. drive motor of the pump
must be switched off, external supply to the actuating system
interrupted).

When the closed-loop control electronics is de-energised,


the swashplate of the control pump is pressed by external
pressure to the negative limit stop (100 % flow is displaced
from the system to the tank).

Command values for pressure and flow must always be


greater than zero (pcomm 3 bar, comm 5 %), since, due to
drift or imprecise settings, there is not exact zero pressure
or zero swivel angle. Smaller command value selections
can lead to cavitation in the worst case.

When a fault is recognized, the output stage is not switched


off. In the case of an active error message, the machine

The actual pressure values must not be smaller than 10 bar


for longer than 10 minutes (lubrication).

679
RE 30 027/06.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEC

7/14

Technical data (for applications outside these parameters, please consult us!)
General
Drive speed
Size
Weight Pump without thorugh-drive, incl. high-response valve
additionally, pre-load valve
additionally, with ext. supply of actuating system

n See RE 92711 (sizes 28 140) and RE 92712 (size 18)


Size
18
28
45
71
100
140
kg
14
17
23
35
47
62
kg
3.3
3.3
3.3
6.3
6.3
6.3
kg
2
2
2
2
2
2

Hydraulic
Max. permissible operating pressure

pmax 250 bar 1) (280 bar after consultation)

Required min. actuating pressure

pmin 20 bar
20 to + 70 C

Hydraulic fluid temperature range


Hydraulic fluid

Mineral oil (HL, HLP) to DIN 51524

Fluid cleanliness

Max. permissible degree of contamination of the hydraulic fluid


to NAS 1638 class 7 or 18/16/13 to ISO 4406 (for particle
size 2/5/15 m)

Electrical
Operating voltage
Operating range
Upper limit value
Lower limit value
Current consumption (in steady-state control operation)
Nominal current
Maximum current

UO 24 VDC + 40 % 5 %
uO(t)max 35 V
uO(t)min 21 V
Inom 0.6 A
Imax 1.25 A

Inputs
Actual pressure value (depending on actual value input,
see ordering code)
Current input (ordering code C)
lO
Voltage input (ordering code V)
UO
Voltage input (ordering code D)
UO
Voltage input (ordering code E)
UO
Voltage input (ordering code F)
UO

Uin 1 0 to 10 V; Ri = 220 k
Uin 2 10 to 10 V; Ri = 100 k

2 analogue inputs
2 digital inputs

4 to 20 mA; load Rl = 100


0 to 10 V; Ri = 220 k
0 to 5 V; Ri = 110 k
1 to 10 V; Ri = 220 k
0.5 to 5 V; Ri = 110 k

logic 0 (low) 8 V
logic 1 (high) 14 V
Re 3 k 10 %

Outputs:
2 analogue outputs
Error message
CAN bus
Physical bus properties
Signal transmission
Bus plug
Protocol
Electrical connection

low-active

UO 10 V
Imax 2 mA
Ua UO 5 V; 10 mA (short-circuit-proof); error: UO < 1 V
ISO 11898-24V
Differential, two-wire cable
M12x1 plug, 5-pin
CANopen for Industrial Systems CiA Standard 301 Version 3.0
Plug-in connector, 12-pin, N11REFF, DIN 43 5632)

Permissible ambient temperature range

0 to 50 C

Storage temperature range

0 to 70 C

Type of protection to DIN 40 050


1)

For supplements, see sales information (engineering aids)


RE 30 030-01-V

2)

Separate order, see page 8 (electrical connection)

P 65 with plug-in connector mounted and locked


Note!
For details regarding environment simulation tests in the fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 30 027-U (declaration on environmental compatibility).

05

680
8/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC RE 30 027/06.04

Electrical connection
Central connection
Plug-in connector to E DIN 43563-B (12-pin),

Plug-in connector without cable (kit)

Material no. R900884671

Detail X

Plug-in connector with cable set 2 x 5 m

Material no. R900032356

Plug-in connector with cable set 2 x 20 m

Material no. R900860399

5
6
7

4
3

10
11

90
X1: Pin assignment of component plug or plug-in connector and cable set
Pin

Assignment

+ UO

0V

PE

Code
1

L0

Supply cable
3 x 1.0 mm2

Ground

green/yellow

Fault

white

M0

yellow

U in 2 (AI2)

green

Uout 2

violet

U in 1 (AI1)

pink

Uout 1

red

Digital IN1(DI1)

brown

10

Actual pressure value H

black

11

Actual pressure value L

Signal cable
10 x 0.14 mm2;
shielded
(Shield must be connected at
one end in the control cabinet!)

blue
grey

n.c.

Top view of component socket


X2: Connection of HM 16 pressure transducer
and serial interface (RS232) (component socket M12x1)
Pin

Assignment
(DMU)

Pin

+ UO

Assignment
RS232
RD (RS232)

Reference L0

3
Signal

Assignment

Pin

5
2

TD (RS232)

X3: CAN bus connection and digital input 2 (DI2),


shielded (component plug M12x1)
Pin

Assignment

Reserved

CAN-GND

Digital IN2 (DI2)

CAN-High

CAN-Low

Top view of component plug


3
4

5
2
1
21

Suitable connection plug for actual pressure value input for version F: Plug-in connector type M12x1 (shielded version)

In the con- L0
trol cabinet
bridge
between
M0
pin 2 and 4
PE

+UB

Uout 1

3
2

PE

CANopen
interface

Parameter 3)
set call-ups

Command value call-ups3)

CAN-L
CAN-H

U
M0

ULP
10V
+15V
15V
+5V
L0

(p x )max

soll 2) 2)3)

3)
psoll2) 2)

Swivel angle
controller

Pressure
controller

Power
controller

Controller
parameter set

Uout 11)

1)

1)

Uout 21)

11

X1
10

5V 3V

L0

ULp

L0

10V

U/I

1) For diagnosis purposes only


2) Optional: analogue command values
3) Optional: command value call-ups
and/or change-over of parameter set

Minimum value
generator

Closed valve
control loop

4
3

X2
1

Swievel angle acquisition

piact
(4..20 mA, 0..10V
0..5V or 1..10V,
0.55V, 020mA)

HM16

SYDFEC

Uout 2

Uin 2

Uin 1

Digital IN1

CAN-GND
Digital IN2

CAN-H

X3
5
4

AI-1

CAN-L

Monitoring
Diagnosis

ist

X1
3

pist

Error message
(0V = error)

soll
psoll

RE 30 027/06.04

681
Industrial Hydraulics Bosch Rexroth AG
9/14

Block circuit diagram / pin assignment of integrated electronics for SYDFEC

05

682
10/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC RE 30 027/06.04

Scope of functions
Structure of the closed-loop control electronics

Master/slave operation:

Analogue valve position controller

- The master receives command values from the machine control and sends commands value to the slave

Digital swivel angle controller

- The machine control does no longer send command values to


the slave

Digital pressure controller


Digital power controller
Controller parameter sets

The assignment of master and slave(s) can be optionally configured by means of SDO. Several master/slave groups are possible.

16 controller parameter sets can be selected in real time via


PDO (e.g. optimization to different oil volumes).

Special function for change-over of injection process/


pack-and-hold pressure

Default values are pre-assigned to these controller parameters,


which can be adjusted by means of SDO or the PC software
WIN PED. It is possible to select 4 controller parameter sets
via 2 switching inputs, if no CAN bus is used.

Command values can be adjusted by means of SDO for packand-hold pressure.

Power limit

Automatic calibration functions


Offset of the pressure transducer
Valve characteristic curve correction

can be changed or switched off by means of SDO

Swivel angle zero point

Leakage compensation

Swivel angle gain

can be cut in or out by means of PDO,

Leakage compensation

value can be configured (manual or automatic calibration)

Corrective values can be called from the control.

Pressure transducers

Monitoring functions

Up to 4 pressure transducers can be connected (fading function)

CAN communication

Master/slave function

System deviation

Direct connection of master and slave pump via CAN bus with
PDO or analogue signals.

Cable break of valve, swivel angle transducer, pressure transducer

Stand-alone operation:

Temperature

- Command values from the machine control

Supply voltage
Internal command value ramps
Pressure

Communication via CAN bus

Flow

Protocol according to CANopen (Communication for Industrial Systems CiA Standard 301 Version 3.0)
Receipt of pressure and flow command values (PDO, real time)
Sending of actual pressure and flow values (PDO, real time)
Certain control options can be selected via the control byte (PDO)
The status byte (PDO) shows the internal state of the DFEC
Changes to settings via SDO

Optional command value sourve: CAN bus, analogue signals, command value call-ups
The command values for pressure and flow can be fed forward from different command value sources:
CAN bus (command values for pressure and flow via PDO)
2 analogue inputs (1 command value input each for pressure and flow)
2 switching inputs (4 command values each for pressure and flow)
Control loop quality SYDFEC (the given values are only valid in conjunction with components associated to the system according to the type code!)
Swivel angle control

Pressure control 1)

Linearity tolerance

1.0 %

1.5 % (1% 2))

Temperature error

0.5 %/10 K

0.5 %/10 K

Hysteresis

0.2 %

0.2 %

Repeatability

0.2 %

0.2 %

1)

Without consideration of pump pulsation

2)

When using the integrated calibrating functions

683
RE 30 027/06.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEC

11/14

Transfer function for swivel angle command value step-change with 360 spool (version A)
Actual swivel angle value in %

Actual swivel angle value in %

Sizes 18, 28, 45, 71 p = 20 bar


100
80
60
40
20

30

60
90
Time in ms

120

60
40
20

Actual swivel angle value in %

Size 100 p = 50 bar


100

30
60
Time in ms

90

60
40
20

30

Size 140 p = 50 bar

60
Time in ms

90

Actual swivel angle value in %

80
60
40
20

30

60
90
Time in ms

120

40
20

30

60
90
Time in ms

120

30

60
90
Time in ms

120

30

60
90
Time in ms

120

30

60
90
Time in ms

120

100
80
60
40
20

100
80
60
40
20

120

100

60

120

80

Actual swivel angle value in %

Actual swivel angle value in %

80

80

Actual swivel angle value in %

Actual swivel angle value in %

Sizes 18, 28, 45, 71 p = 50 bar


100

100

100
80
60
40
20

05

684
12/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC RE 30 027/06.04

Transfer function for pressure command value step-change for SYDFEC with 360 spool (version A)
The curve shapes and control times given here are achieved when the relevant standard parameter set is selected. With an optimized system, shorter times may be achieved.
140
120

140
psoll

120
pist

100

Pressure p in bar

Pressure p in bar

100
80
60
pist

40

T95% in ms with a connected


hydraulic fluid volume (lines
and consumer)

20

80
60

psoll

40

150 ms

5 10 L

200 ms

15 25 L

250 ms

For pressures up to 40 bar,


the response time values
are greater.

20

<5L

0
T95% Control time

T95% Control time

Unit dimensions SYDFEC (in mm)


Sizes 18 to 140
(Valve installation orientation 0; shaft version S; without through-drive N00)
Pre-load valve (optional)

CAN bus connection (X3)


Connection of HM 16
(X2)
A7

A4

A8 III

A5

A6 I

A1

A6

A6 II

Space required to remove


plug-in connector

Z
S

A3
A8 I

A8 II

Connection of HM 16 (X2)
CAN bus connection (X3)

Mounting of control valve


with anti-clockwise direction of rotation

Mounting of control
valve with clockwise
direction of rotation
Pilot oil port Z

Size

A1

A3

A4

A5

A6

A6 I

A6 II

A7

A8 I

A8 II

A8 III

18

120

198

158

63

178

63

115

60

233

125

100

28

128

208

158

63

195

80

115

60

243

135

115

45

134

218

158

63

205

90

115

60

253

145

125

71

146

232

158

63

254

104

150

60

267

159

150

100

151

237

158

63

247

100

147

60

272

164

150

140

162

250

143

78

257

110

147

60

285

182

150

Dimension A7 installation space required for CAN bus plug-in connection and optional connection for HM16 pressure transducer

685
13/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC RE 30 027/06.04

Example of nameplate for an SY2DFEC pump combination


Word mark
Material number

Short material text

Date of production
Production job order no.
MNR: R901016065 FD: 39022

SN: 0000001

SY2DFEC-2X/071-045/+R901016048

Designation of origin

000120267633
7087

Made in Germany
Fabr. Nr

Fabrication number

73939649

MINERALL
Drehrichtung

Plant

Direction of rotation

MADE .................

Production location

Note!
Please have the material number and the fabriation number at hand in
the case of queries with regard to the pump combination.

Engineering notes
Always shield command and actual value cables.
The distance to aerial lines or radio equipment must be at least 1 m.
Signal cables must not be installed near power cables.
Supplementary notes on the SYDFEC control system can be found in RE 30 030-01-V.

05

686
14/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEC

RE 30 027/06.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

All rights reserved by Bosch Rexroth AG, also in the case of patent
applications. Any right of disposal such as right of copying or distribution
lies with us.
The data specified only serves to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The details stated do not release you from the
responsibility for carrying out your own assessment and verifcation. It must
be remembered that our products are subject to a natural process of wear
and ageing.

687

RE 30030/01.04
Replaces: 05.02

Pressure and flow


closed loop system

1/14

Type SYDFEE

Series 2X
H6723

Overview of contents
Contents
Features
Ordering details
Function, section
Operating principle
Technical data
Block circuit diagram
Characteristic curves
Unit dimensions
Electrical connections
Name plate details (example)
Engineering guidelines

Features
Page
1
2, 3
4
5, 6
7
8
9, 10
11
12
13
13

The DFEE control is used for the electro-hydraulic closed loop


control of the pressure and swivel angle of an axial piston pump
The SYDFEE.. closed loop control system consists of the
following components:
A10VSO axial piston pump with built-on proportional valve as
the pilot valve VT-DFPE-2X/..
The VT-DFPE..-2X/.. valve with integrated analogue control and
closed loop control electronics realises the complete closed
loop control function for the DFEE system
The acquisition of the swivel angle is via a rotary angle sensor
type VT-SWA-1-1X which is a hall effect based sensor
Pump pre-load valve (optional)
Combination pumps are possible
HM16 (optional) pressure transducer for fitting into the pump
or the pre-load valve with a direct connection to the closed
loop control electronics result in a plug-free complete system.

Further information regarding this system:


Component description, A10VSO
RE 92712 for NS 18, RE 92711 for NS 28 to140
Component description, VT-SWA-1-1X rotary angle sensor
RE 30 268
Component description, HM 12-1X / HM 13-1X pressure transducer RE 29933
Component description, HM16-1X pressure transducer
RE 30266
Component description, VT-DFPE-2X/ pilot valve
RE 29016
Component description, SYDZ 0001-1X pump pre-load valve
RE 29255
Additional information regarding the SYDFEE system can be found in:
Sales inforamtion (engineering guidelines)
RE 30030-01-V

05

688
2/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEE

RE 30030/01.04

Ordering details
SYDFEE 2X

12

1)

Further details
in clear text
Pre-load valve
1 = Pressure limitation
200 bar
2 = Pressure limitation
250 bar
3 = Pressure limitation
300 bar
X=
Without
pre-load valve
Pressure transducer
C = HM 12 (4 to 20 mA)
measuring range up to 315 bar
G = HM 13 (0 to 10 V)
measuring range up to 315 bar
L = HM 16 (0.5 to 5 V))
measuring range up to 315 bar 7)
with connection cable 0.5 m
and plug-in connector M12
X = Without pressure transducer
Actual pressure input
Current input 4 20 mA

Single pump
Pump
combination 2)

Series 20 to 29
= 2X
(20 to 29: unchanged installation
and connection dimensions)
Pump A10VSO
Nominal Size 18
Nominal Size 28
Nominal Size 45
Nominal Size 71
Nominal Size 100
Nominal Size 140

= 018
= 028
= 045
= 071
= 100
= 140

Direction of rotation
Clockwise (pref. types
for through drive pumps)
Anti-clockwise

=R
=L

Pressure fluid
Mineral oil to DIN 51 524 (HL / HLP)

=P

Shaft end
( = Preferred types for through drive pumps)

NS

18

28

3)

4)

3/4

5)

7/8

45

71

100

=R

C
=
V=
Voltage input 0 10 V
D=
Voltage input 0 5 V
E=
Voltage input 1 10 V
F = Voltage input 0.5 5 V 8)

100 140

Electronic sub-assembly, optional


0=
No option
1 = Without leakage oil compensation

140

22 25 32 40 45

Connection flange (
NS

18

ISO 2-hole

ISO 4-hole

SAE 2-hole

1 1/2 1 3/4

1 1 1/4

=P
=S

= available)
28

45

71

=A

=C

Actuator line connections


Pressure connection B
SAE, on opposite sides
Suction connection S
metric mounting heads
Through drive (see table on page 3)
Without through drive
Through drive without hub for mounting:
(All built-on pumps are with a SAE splined shaft)
Centre dia. (mm)

Pump to be fitted

82.55
100
125
180
101.6
127

A10VSO18
A10VSO28/45
A10VSO71/100
A10VSO140
Gear pump
Gear pump

Additional function power limitation


A=
Without power limitation
B=
With power limitation

=B

Valve, mounting orientation, integrated electronics


0=
Radial to the pump axis
2 = 90 in the direction of the connection plate

= 12
A=
= N00
0000 =
0479 =
0487 =
= KC1 6)
= KD3 6)
= KD5 6)
= KD7 6)
= KC3 6)
= KC5 6)

With single pumps the hub must be ordered separately.


With combination pumps the hub is included within the scope of
supply.

1)
2)
3)
4)
5)
6)
7)

Accessories:
For plug-in connectors (separate order) see page 12

8)

Valve, spool version


Basic pump version
Standard (internal pilot oil)
Remote supply (NS 18 100)
Remote supply (NS 140)

See ordering example at the top of page 3


See ordering example at the top of page 3
Cylinderical with key, DIN 6885
SAE spline profile
SAE spline profile (higher through drive torque)
The through drive is covered by a cover plate
For direct connection to the integrated electronics
version actual pressure input F
Connection via component socket M12

689
RE 30030/01.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEE

3/14

Ordering details
Ordering example
1) Ordering example for a single pump
SYDFEE-2X/100R-PSA12N00-0479-A0A0VGX
2)

Ordering example for a combination pump


Both of the type codes are to be connected by a +. (Material No. of the 1st pump + Material No. of the 2nd pump)
SY2DFEE-2X/100-100/
R900709780
+
R900709780
SY2DFEE-2X/100-100/ SYDFEE-2X/100R-PSA12KD5-0000-A0A0CCX + SYDFEE-2X/100R-PSA12KD5-0000-A0A0CCX
Double
pump
Nom. size of the
front pump
Nom. size of the rear pump
Material No. of the front pump
(or in clear text if the Material No. is not known)
Material No. of the rear pump (or in clear text if the Material No. is not known)
Preferred types: single pump
Type

Preferred types: through drive pumps for combination pumps


Material No.

Type

Material No.

SYDFEE-2X/018R-PSC12N00-0000-A0A0CCX R900708503

SYDFEE-2X/028R-PRA12KD3-0000-A0A0CCX R900709773

SYDFEE-2X/018R-PSC12N00-0000-A0A0CC2

R900708504

SYDFEE-2X/045R-PRA12KD3-0000-A0A0CCX R900709774

SYDFEE-2X/028R-PPA12N00-0000-A0A0CCX

R900708505

SYDFEE-2X/071R-PRA12KD5-0000-A0A0CCX R900709775

SYDFEE-2X/028R-PPA12N00-0000-A0A0CC2

R900708506

SYDFEE-2X/100R-PSA12KD5-0000-A0A0CCX

R900709780

SYDFEE-2X/045R-PPA12N00-0000-A0A0CCX

R900708507

SYDFEE-2X/140R-PSB12KD7-0000-A0A0CCX

R900709781

SYDFEE-2X/045R-PPA12N00-0000-A0A0CC2

R900708508

SYDFEE-2X/071R-PPA12N00-0000-A0A0CCX

R900708510

SYDFEE-2X/071R-PPA12N00-0000-A0A0CC2

R900708511

SYDFEE-2X/100R-PPA12N00-0000-A0A0CCX

R900708512

SYDFEE-2X/100R-PPA12N00-0000-A0A0CC2

R900708513

SYDFEE-2X/140R-PPB12N00-0000-A0A0CCX

R900708514

SYDFEE-2X/140R-PPB12N00-0000-A0A0CC2

R900708515
Nominal size

Through drive (

= available)

18

28 45

71

100

Without through drive

140
N00

With through drive for mounting an axial piston pump, a gear pump or radial piston pump
Mounting flange

Shaft/coupling (separate order)

For fitting a:

ISO 100, 2-hole

Splined shaft 7/8 22-4 (SAE B)

A10VSO 28 (shaft S or R)

ISO 100, 2-hole

Splined shaft 1 25-4 (SAE B-B)

A10VSO 45 (shaft S or R)

ISO 125, 2-hole

Splined shaft 1 1/4 32-4 (SAE C)

A10VSO 71 (shaft S or R)

ISO 125, 2-hole

Splined shaft 1 1/2 38-4 (SAE C-C) A10VSO 100 (shaft S)

ISO 180, 4-hole

Splined shaft 1 3/4 44-4 (SAE D)

82-2 (SAE A, 2-hole) Splined shaft 5/8 16-4 (SAE A)

A10VSO 140 (shaft S)

KD3

KD3
KD5
KD5

1PF2G2, PGF2

KD7
KC1

82-2 (SAE A, 2-hole) Splined shaft 3/4 19-4 (SAE A-B)

A10VSO 10, 18 (shaft S)

101-2 (SAE B)

Splined shaft 3/8 22-4 (SAE B)

A10VO 28 (shaft S), PGF3

KC3

101-2 (SAE B)

Splined shaft 1 25-4 (SAE B-B)

A10VO 45 (shaft S), PGH4

KC3

127-2 (SAE C)

Splined shaft 1 1/4 32-4 (SAE C)

A10VO 71 (shaft S)

127-2 (SAE C)

Splined shaft 1 1/2 38-4 (SAE C-C) A10VO 100 (shaft S), PGH5

152-4 (SAE D)

Splined shaft 1 3/4 44-4 (SAE D)

A10VO 140 (shaft S)

KC1

KC5
KC5

KC6

05

690
4/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEE

RE 30030/01.04

Function, section
The closed loop control of pressure and swivel angle of the
A10VSO SYDFEE system variable displacement pumps is via
an electrically controlled proportional valve (2). The proportional valve determines the position of the swashplate (1) via the
control piston (4). The displaced flow is proportional to the
position of the swashplate. The control spool (3), which is preloaded by a spring (5), is permanently subjected to the pump
pressure.
With a non-rotating pump and the control system at zero
pressure, the swashplate is held in position + 100 % by the
spring (5). With a driven pump and a de-energised proportional
solenoid (8) the system regulates to zero stroke pressure as
the valve spool (9) is pushed to the initial position by the spring
(10) and, therefore the pump pressure p is applied to the control piston (4) via valve port A. A balance between the pump
pressure at the control piston and the spring force (5) is achieved between 8 to 12 bar. This basic setting is obtained with
e.g. de-energised valve electronics (= zero stroke operations).
The control of the proportional valve is taken over by the
analogue electronicis (11) which are integrated into the valve.
The closed loop control electronics processes all of the control
signals required to operate the A10VSO variable displacement
pump in the closed loop pressure and flow mode.
The closed loop control electronics has separate command
value inputs for the pressure and swivel angle via the central
plug (12); For the optional power limitation, the command value
is adjusted via an internal potentiometer. The HM16 pressure
transducer is connected to connection P of the pump or when
the SYDZ pre-load valve is fitted to connection MP1 and to the
M12 component socket (13). Alternatively an external pressure transducer can be connected via the central plug (12). A
position transducer with integrated electronics (7) fitted on
the pump determines the swivel angle actual value. The actual
value is processed in the amplifier and compared with the

given command value. The minimum value generator ensures,


automatically, that only the allocated controller is active at the
required working point. Thereby, a system value (pressure,
swivel angle or [optional] power) is exactly controlled, the other
two values lie under the stated command values. The output
signal of the minimum value generator becomes the command
value for the valve control circuit.
The actual value for the valve spool position is sensed using
an inductive position transducer (6). The output value of the
valve position controller defines, via the amplifier output stage,
the current through the proportional solenoids (8). As soon
as the working point is reached the proportional valve control
spool (9) is switched to the mid position.
If the higher-level controllers demand an increase of the swivel
angle (increase in flow), then the valve spool (9) must be
moved from the mid position (connection of the control piston
(4) via valve port A T) until the swivel angle has reached the
required value. The movement of the valve spool against the
force of the spring (10) is achieved by accordingly increasing
the electrical current through the proportional solenoid (8).
The reduction of the swivel angle (reduction in flow) is
achieved by connecting the control piston (4) from P A.
Control system supply
There are three ways of supplying the pumps hydraulic control
system with pilot oil:
1. Internal, without pre-load valve (only possible for system
pressures > 20 bar)
2. Internal, with pre-load valve (system pressure 0 100%)
3. Remote supply via a shuttle valve - automatic switchover
internal / external via a shuttle valve sandwich plate
(take the sales information stated within RE 30030-01-V
into account!)

8
P A T

10
1

100%

Zero
stroke
drive

Type SYDFEE-2X/-PP

+ 100%

9
2
12
11
13 (M12) for HM16,
only version F

691
RE 30030/01.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEE

5/14

Operating principle: with internal supply for the control system (inlet supply)
Actuator
The prescribed maximum
pressure safety can be
omitted when the pre-load
valve is used.

(qV; p)

P1

MP1 Pre-load valve (optional)

P1

20 bar

Optional 1)

P
U/I

Pressure transducer

P
T

P
Bleed

PP

Pressure command value 0 to + 10 V

Pilot valve VT-DFPE-2X/

Flow command value 0


(10) to + 10 V
Error

s
U

B P

A
U

Pump

L1

1)

Mounting possibilities
Pressure transducer

With SYDZ 2)

Without SYDZ 2)

Notes

HM16

MP1

Only in conjunction with the electronic version


actual pressure input F

HM12 / HM13

P1

P1

Preferably in the vicinity of the actuator

05

692
6/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEE

RE 30030/01.04

Operating principle: remote supply for the control system


Actuator

(qV; p)
p
2)

max

Optional 3)

P1
P

P
U/I Pressure transducer

Pressure command value 0 to + 10 V

Pilot valve VT-DFPE-2X/

Flow command value


0 (10) to + 10 V

Error

s
U

A
P
20 bar

B P
U

4)

Z (External
s

pilot oil pressure)

M
P
1)

0,2 bar
S

Pump

L1

1)

The anti-cavitation valve must be fitted (a check valve with


0.2 bar spring), to prevent cavitation in the case of a fault.

2)

The maximum pressure safety is the responsibility of the


customer!

3)

4)

L
The upper limit for the external pilot oil supply pressure
has to be taken into account! (compare RE 30030-01-V),
recommendation: 20 bar absolute.

Pressure transducer

Mounting possibilities

Notes

HM16

Only in conjunction with the electronic version actual pressure input F

HM12 / HM13

P1

Preferably in the vicinity of the actuator

Attention!
With the remote supply of the control system the feature
where the pump swivels to the zero stroke position when the
control electronics are de-enegised is deactivated.

(e.g. switch off the pump, drive motor, interrupt the remote
pressure source).

With de-enegised control electronics the control pumps


swashplate is pushed onto the negative stop via the remote
pressure (100 % of the flow is passed to tank).

Command values for pressure and flow must be greater than zero
(pcom.l 3 bar, com. 5 %), as due to drift or inacurate setting
no exact pressure zero or swivel angle zero exists. Smaller
command values can inunfavourable conditions lead to cavitation.

When a fault is determined the output stage is not switched


off. With an active fault signal the machine control must react

The pressure actual value must not be longer than 10 bar for
more than 10 minutes (lubrication).

693
RE 30030/01.04

7/14

Industrial Hydraulics Bosch Rexroth AG

SYDFEE

Technical data (for applications outside these paramters, please consult us!)
General
Drive RPM

Nominal size

See RE 92711 (NS 28 140) and RE 92712 (NS 18)

NS

18

28

45

71

100

140

kg

14

17

23

35

47

62

Additional, pre-load valve

kg

3.3

3.3

3.3

6.3

6.3

6.3

Additional, with external control system supply

kg

Weight Pump without through drive incl. control


valve

Hydraulic
Maximum permissible operating pressure

pmax

250 bar 1) (280 bar after consultation)

Adjustment pressure

pmin

20 bar

pmax with external pilot oil supply

30 bar

Pressure fluid temperature range

20 to + 70 C

Pressure fluid

Mineral oil (HL, HLP) to DIN 51 524

Degree of contamination

Maximum permissible degree of contamination of the pressure fluid is to


NAS 1638 class 7 or 18/16/13 to ISO 4406 (for particle sizes 2/5/15 m)

Electrical
Operating voltage
Operating range
Upper limiting value

uB(t)max

35 V

Lower limiting value

uB(t)min

21 V

UB

Power requirements (in static closed loop control operation)


Nominal current
INom.
Maximum current
Inputs

Outputs

Command values (pressure and swivel angle)

Imax
Ue

24 VDC + 40 % 5 %

0.6 A
1.25 A
0 to 10 V; RE = 100 k

Switch TD (only with ordering detail A w/o additional functions)


"Off"
Ue
"On"
Ue

< 0.6 V
> 21 V

Actual pressure valve


(depending on the actual pressure input, see ordering code)
Current input (ordering detail C)
RB
Voltage input (ordering details V, D, E, F)
RE

100
100 k

Actual values
Pressure
Swivel angle

Ua
Ua

0 to 10 V/1.5 mA
10 V/1.5 mA

Fault message L active

Ua

UB 5 V; 10 mA (short-circuit proof); error: Ua < 1 V

Power limitation H active


(only with ordering detail B with additional function)

Ua

Permissible ambient temperature range


Storage temperature range
Protection to DIN 40 050

1)

For supplements see the sales information


(engineering guidelines) RE 30030-01-V

2)

Separate order, see page 12 (electrical connections)

UB 5 V; 10 mA (short-circuit proof); inactive: Ua < 1 V


Plug-in connector 12-pin, N11REFF, DIN 43 563 2)

Electrical connection

0 to 60 C
0 to 70 C
IP 65 with integrated and fixed plug-in connector

Note: For details regarding the environmental simulation


test covering EMC (electro-magnetic compatibilty),
climate and mechanical loading see RE 30030-U
(declaration regarding environmental compatatility).

05

PE

1
2

+ UB

> 80 C

L0

10 V

5V3V

Only version F

Cable break

10 V

t = 1s

Switch TD only for version without the additional function of power limitation (ordering detail A)

> + 11,5 V
< 11,5 V

Swivel angle
controller

PD

2)

10 V
+ 15 V
15 V
L0

> + 11,5 V
< 0,5 V

MIN

DIV
max

> + 3,3 V
< 3,3 V

MIN

Only for the version with the additional function of power limitation (ordering details B)

L0

L0

L0

L0

(p ) max max = (p )max


pact.

R3

Pressure
controller

xp

+ UB

1)

R2

L0

PD

0F

Swivel angle
transducer

SYDFEE

ULP

U(i)

1 ^
= max < com.

1 ^
= x < xp

Switch TD 1)

Industrial Hydraulics

L0

L0
10
11

ULP

^ 0 V)
Error message (=

In terminal box:
bridge between
pins 2 and 4

act. 10 V to + 10 V

M0

com. 0 (10) to + 10 V

pact. 0 to + 10 V

pact. 4 to 20 mA H
or 0 to + 10 V
0 to 5 V, 1 to 10 V L

HM16

&

L0

Bosch Rexroth AG

2)

pcom. 0 to + 10 V

Switch TD 1) or
power limiter active

L0

8/14

694
RE 30030/01.04

Block circuit diagram / pin allocation of the integrated electronics for SYDFEE (type VT-DFPE-

695
RE 30030/01.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEE

9/14

Control loop control accuracy SYDFEE (the stated values are only valid when the system applicable components, as per the type code,
are used!)
Closed loop swivel angle control

Closed loop pressure control 1)

Linearity tolerance

1.0 %

1.5 %

Temperature drift

0.5 %/10 K

0.5 %/10 K

Hysteresis

0.2 %

0.2 %

Repeatability

0.2 %

0.2 %

1)

Without taking the pump pulsation into account

Transient function with a pressure command value jump SYDFEE with a 360 spool (version A)
The stated curve forms and control times can only be achieved by optimising the pressure controller.
140

140

pcom.

120
Pressure p in bar

Pressure p in bar

120

T 95% in ms with an attached


pressure fluid volume (pipes
and actuator)

100
80
60

pact.

40
20

pact.

100
80

<5L
pcom.

60

5 10 L

200 ms

15 25 L

250 ms

For pressures up to 40 bar


the response time values
are higher

40
20

150 ms

0
T95% Control time

T95% Control time

Optimising the pressure controller for the SYDFEE (setting the jumpers)
Switch position
2)

2)

TD OFF

6.25

7.5

10

12.5

15

20

25

6.25

7.5

10

12.5

15

20

25

TD ON

7.5

10

12.5

15

20

25

30

35

12.5

15

20

25

30

35

40

45

The fluid volume of the connected pipes and actuators (in L)

05

696
10/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEE

RE 30030/01.04

Transient functions with swivel angle command value jump with a 360 spool (version A)
Actual swivel angle value in %

Actual swivel angle value in %

NS 18, 28, 45, 71 p = 20 bar


100
80
60
40
20

30

60
90
Time in ms

120

80
60
40
20

30

60
90
Time in ms

Actual swivel angle value in %

Actual swivel angle value in %

80
60
40
20

30

60
90
Time in ms

Actual swivel angle value in %

Actual swivel angle value in %

80
60
40
20

30

60
90
Time in ms

120

40
20

30

60
90
Time in ms

120

30

60
90
Time in ms

120

30

60
90
Time in ms

120

30

60
90
Time in ms

120

100
80
60
40
20

100
80
60
40
20

120

NS 140 p = 50 bar
100

60

120

NS 100 p = 50 bar
100

80

Actual swivel angle value in %

Actual swivel angle value in %

NS 18, 28, 45, 71 p = 50 bar


100

100

100
80
60
40
20

697
RE 30030/01.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEE

11/14

Unit dimensions SYDFEE (dimensions in mm)


Nominal sizes 18 to 140
(valve assembly orientation 0; shaft type S; without through drive N00)

Space required to remove


the plug

Pre-load valve (optional)


HM16 pressure transducer connection
(optional)

A4

A8 III

A5

A6 I

A1

A6

A6 II

A7

Z
S

A3
A8 I

A8 II

Control valve mounting


location for anti-clockwise
direction of rotation

Control valve mounting


location for clockwise
direction of rotation

NS

A1

A3

A4

A5

A6

A6 I

A6 II

A7

Pilot oil connection Z


A8 I
A8 II
A8III

18

120

198

158

63

178

63

115

60

233

125

100

28

128

208

158

63

195

80

115

60

243

135

115

45

134

218

158

63

205

90

115

60

253

145

125

71

146

232

158

63

254

104

150

60

267

159

150

100

151

237

158

63

247

100

147

60

272

164

150

140

162

250

143

78

257

110

147

60

285

182

150

Dim. A7 required installation room for the optional connection of the HM16 pressure transducer

05

698
12/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEE

RE 30030/01.04

Electrical connections
Central connection
Plug-in connector to E DIN 43 563-B (12-pin), separate order:
X:

Plug-in connector without cable (assembly kit) Material No.


R900884671
Plug-in connector with cable set 2 x 5 m Material No. R900032356
Plug-in connector with cable set 2 x 20 m Material No. R900860399

5 4
3
10
7 11 9 2
8
1
6

90
Allocation of the component plug or plug-in connector and cable set
C
For type SYDFEE V /.V
D
E
Pin

Allocation

Code

1
2
PE

+ UB
0 V^
= L0
Earth

1
2
Green/yellow

3
4
5
6
7
8
9 1)
10
11
n.c.

Fault
M0
com.
act.
pcom.
pact.
Switch TD or power limitation
Pressure actual value H
Pressure actual value L

White
Yellow
Green
Violett
Pink
Red
Brown
Black
Blue
Grey

1)

Version without power


limitation (A):
Switched input
Switch TD

Supply cable
3 x 1.0 mm2

Version with power


limitation (B):
Switched output
power limitation active

Signal cable
10 x 0.14 mm2;
Screened
(The screen must
be attached at
one end to the
control!)

HM 16 pressure transducer
connections (unit socket M12x1)

For type SYDFEEF/.V


Pin

Allocation

Code

1
2
PE

+ UB
0V^
= L0
Earth

1
2
Green/yellow

3
4
5
6
7
8
9 1)
10
11
n.c.

Earth
M0
com.
act.
pcom.
pact.
Switch TD or power limitation
Reserved
Reserved

White
Yellow
Green
Violett
Pink
Red
Brown
Black
Blue
Grey

Pin
Supply cable
3 x 1.0 mm2

1
3
4

Allocation
+ UB
Ref.
Signal

View on the unit socket


Signal cable
10 x 0.14 mm2;
Screened
(The screen must
be attached at
one end to the
control!)

5
2

Matching connection plug for the


actual pressure value input for
version F: Plug-in connector type
M12x1 (screened version)

699
RE 30030/01.04

Industrial Hydraulics Bosch Rexroth AG

SYDFEE

13/14

Name plate example for a SY2DFEE combination pump


Shown is the name plate of the built-on NS 45 pump!

Line 1
Serial No. (related to the manufacturing batch)

Line 3
Manufacturing No.

Line 5
Fabrication No.

0000001
SY2DFEE-2X/071-045/+00921711
20928065
Baujahr FD...
Mat. Nr *R900921768*
MINERALL
Fabr. Nr 73939649
Drehrichtung
MADE ...................

00215052

Line 4
Combination pump
Material No. (for single pump
identification see line 2)

Line 2
Combination pump clear text with
the Material No.
(= technical version) of
the built-in NS 45 pump

Build year

Direction of rotation
Production location

For the answers to any questions regarding the combination pump the Material No. (line 4) and the
Fabrication No. (line 5) are required.

Engineering guidelines
Command values must only be switched via relays having gold contacts (small voltages, small currents)
Always screen the command and actual value cables
The distance to aerial lines or radio sources must be at least 1 m
Do not lay signal cables near power cables
Supplementary guidelines regarding the SYDFEE closed loop control system can be found in RE 30030-01-V

05

700
14/14

Bosch Rexroth AG

Industrial Hydraulics

SYDFEE

RE 30030/01.04

Notes

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

2003 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, duplicated or circulated using electronic systems, in any form or
by any means, without the prior written authorisation of Bosch Rexroth AG.
In the event of contravention of the above provisions, the contravening party
is obliged to pay compensation.
The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information.The details stated do not release you
from the responsibility for carrying out your own assessment and verification. It must be remembered that our products are subject to a natural
process of wear and ageing.

701

Pressure-flow closed loop control


system
Type SYHDFEE

RE 30 035/12.03

1/12

Type SYHDFEE

Nominal sizes 125 to 355


Series 1X
Maximum operating pressure 350 bar
H7126/06

Overview of contents
Contents
Features
Ordering details

Features
Page
1
2 and 3

Function, section

Operating principle

Technical data

Block circuit diagram and connection allocation

Closed loop control circuit accuracy SYHDFEE

Transient function

Optimising the pressure controller

Transient function with a swivel angle


command value jump

The DFE conrol is used for the electro-hydraulic closed loop


control of the pressure and swivel angle of an axial piston pump
The SYHDFEE.. closed loop control system consists of the
following components:
A4VSO axial piston pump with a built-on proportional valve as
the pilot valve VT-DFPE-2X/..
The VT-DFPE..-2X/.. valve with integrated open and closed
loop control electronics contains the complete closed loop
control function of the DFE system
The acquisition of the swivel angle is via a linear sensor type
VT-SWA-LIN-1X which is a hall effect based sensor
Combination pumps are possible

Electrical connections

10

Unit dimensions

11

Example of a name plate

12

Component description, pump A4VSO

Engineering guidelines

12

Component description, valve VT-DFPE

For further information regarding this system see:

Sales information (engineering guidelines)

RE 92 050
RE 29 016
RE 30 030-01-V

05

702
2/12

Bosch Rexroth AG

Industrial Hydraulics

SYHDFEE

RE 30 035/12.03

Ordering details

SYHDFEE 1X

25

Single
pump 1)
Combination pump
2)

Further details
in clear text
Actual pressure input
Current input:
C=
4 20 mA
Voltage input:
V=
0 10 V
D=
05V
E=
1 10 V
F=
0.5 5 V5)

Series 10 19 = 1X
Nom. size 125
Nom. size 180
Nom. size 250
Nom. size 355

= 125
= 180
= 250
= 355

Direction of rotation
Clockwise (preferred type)
Anti-clockwise

Electronic sub-assembly,
optional
0=
Standard
1=
Without
leakage oil compensation

=R
=L

Pressure fluid
Mineral oil to DIN 51524 (HL/HLP) = P
HFC
=F

Additional function
power limitation
Without power limitation
With power limitation

end3)

Shaft
Cyl. shaft with key way DIN 6885
Splined shaft to DIN 5480
(preferred type)

A=
B=

=P
=Z

Connection flange3)
NG 125 355 > ISO 4-hole

0=
Valve mounting orientation
integrated electronics parallel to pump axis
in the direction of the connection plate
(standard)

=B

Actuator line connections


Connections B and S: SAE on side, off-set through 90,
metric fixing threads
2nd pressure connection B1 opposite B - when
delivered blanked off with a flange (standard)
= 25

A=
C=
0000 =
0576 =
N00 =
K99 =

Valve spool version


Standard (for mineral oil to DIN 51524
(HL/HLP) )
4groove spool for HFC pressure fluid
Basic pump version
Standard (internal pilot oil)
Remote supply
Through drive (see table on page 3)
Without through drive
Through drive without hub, without
intermediate flange with cover closed

Through drive without hub, with cover for mounting:


(all combination pumps (2nd) with SAE splined shaft profile)

=
KD34) =
KC34) =

1)

See ordering example at the top of page 3

2)

See ordering example at the top of page 3

3)

For dimensions see table on page 11

4)

The through drive is is covered by a cover plate

5)

Connection via a M12 component socket

6)

Example

Combination pump6)
A10VSO18
A10VSO28/45

Spigot (mm)
82.55
100
Gear pump
101.6
With single pumps the hub and, if necessary, the
intermediate flange must be ordered seperately.
With combination pumps the front hub and, if necessary, the
intermediate flange are included within the scope of supply.

KC14)

703
Industrial Hydraulics Bosch Rexroth AG

SYHDFEE

RE 30 035/12.03

3/12

Ordering details
Ordering example:
1)Ordering

example for a single pump

SYHDFEE-1X/125R-PZB25N000000A0A0F
2)Ordering

example for a combination pump

Both of the type codes are to be connected by a +. (Material No. 1st pump + Material No. 2nd pump)
Possibility 1:

SY2HDFEE1X/ 125 - 045/

R901038404

R901019184

Possibility 2:

SY2HDFEE1X/ 125 - 045/

SYHDFEE-1X/125R-PZB25KD30000A0A0V

SYDFEE-2X/045R-PRA12KD30000A0A0VXX

Combination pump
Nom. size of the front pump
Nom. size of the rear pump
Matarial No. of the front pump (or in clear text if the
Matarial No. is not known)
Combination part
Matarial No. of the rear pump (or in clear text if the Material No. is not known)
Preferred types:
SYHDFEE-1X/125R-PZB25N00-0000-A0A0F
SYHDFEE-1X/180R-PZB25N00-0000-A0A0F
SYHDFEE-1X/250R-PZB25N00-0000-A0A0F
SYHDFEE-1X/355R-PZB25N00-0000-A0A0F

Through drive

Nominal size

= Not available

= The flange is integrated into the connecion plate


125 180 250
zw = Through drive K99 + intermediate flange (sep.
order)
Without auxiliary pump; without through drive

With through drive for mounting an axial piston pump, a gear pump or radial piston pump
Flange
Hub/splined shaft
For mounting an
ISO 125, 4-hole 32x2x30x14x9g
A4VSO/H/G 40

ISO 140, 4-hole 40x2x30x18x9g


A4VSO/H/G 71

ISO 160, 4-hole 50x2x30x24x9g


A4VSO/H/G 125/180
zw
zw
zw
ISO 224, 4-hole 60x2x30x28x9g
A4VSO/G 250

zw
ISO 224, 4-hole 70x3x30x22x9g
A4VSO/G 355

ISO 100, 2-hole 7/8 22-4 (SAE B)


A10VSO28BR31

ISO 100, 2-hole 1 25-4 (SAE B-B)


A10VSO45BR31

ISO 125, 2-hole 1 1/4 32-4 (SAE C)


A10VSO71BR31
zw
zw
zw
ISO 125, 2-hole 1 1/2 38-4 (SAE C-C) A10VSO100BR31
zw
zw
zw
ISO 180, 4-hole 1 3/4 44-4 (SAE D)
A10VSO140BR31

zw
zw
82-2 (SAE A)
5/8 16-4 (SAE A)
PGH2, 3 ; PGF2

82-2 (SAE A)
3/4 19-4 (SAE A-B)
A10VSO10BR31, 18

101-2 (SAE B)
7/8 22-4 (SAE B)
A10VO28BR31; PGF3

101-2 (SAE B)
1 25-4 (SAE B-B)
A10VO45BR31; PGH4

127-2 (SAE C)
1 1/4 32-4 (SAE C)
A10VO71BR31
zw
zw
zw
127-2 (SAE C)
1 1/2 38-4 (SAE C-C) A10VO100BR31;
zw
zw
zw
PGH5
152-4 (SAE D)
1 3/4 44-4 (SAE D)
A10VO140BR31

zw
zw
With through drive shaft, without hub, without intermediate flange,

with blanked off functional cover


3)

K99 + intermediate flange relates dimensionally to the through drive in brackets

355

N00

zw
zw
zw

zw
zw
zw

zw
zw

Kxx 3)
Kxx
(K34)
(K35)
(K77)
KD3
KD3
(KD5)
(KD5)
(KD7)
KC1
KC1
KC3
KC3
(KC5)
(KC5)

zw

(KC6)
K99

05

704
4/12

Bosch Rexroth AG

Industrial Hydraulics

RE 30 035/12.03

SYHDFEE

Function, section
The closed loop control of the pressure and swivel angle of the
A4VSO SYHDFEE system variable displacement pumps is via
an electrically controlled proportional valve (2). The proportional valve determines the position of the swash plate (1) via the
control piston (4). The displaced flow is
proportional to the position of the swash plate. The control
spool (3), which is pre-loaded by a spring (5), is permanently
subjected to the pump pressure.

The minimum value generator ensures, automatically, that only


the allocated controller is active at the required working point.
Thereby, a system value (pressure, swivel angle or [optional]
power) is exactly controlled, the other two values lie under
the stated command values. The output signal of the minimum
value generator becomes the command value for the valve
control circuit.

With a non-rotating pump and the control system at zero


pressure, the swash plate is held in position + 100 % by the
spring (5). With a driven internal pilot oil supply version of the
pump and a de-energised proportional solenoid (8) the system
regulates to zero stroke pressure as the valve spool (9) is pushed to the initial position by the spring (10) and, therefore the
pump pressure p is applied to the control piston (4) via valve
port A. A balance between the pump pressure at the control
piston and the spring force (5) is achieved at approx. 8 bar. this
basic setting is obtained
with e.g. de-energised valve electronics (= zero stroke
operations). Deviating from this, the pump version with an
external pilot oil supply swivels to the negative stop (motor
operation).

The actual value for the valve spool position is sensed using
an inductive position transducer (6). The output value of the
valve position controller defines, via the amplifier output stage,
the current through the proportional solenoids (8). As soon
as the working point is reached the proportional valve control
spool (9) is switched to the mid position.

The control of the proportional valve is taken over by the


analogue electronics (11) which are integrated into the valve.
The closed loop control electronics processes all of the control
signals required to operated the A4VSO variable displacement
pump in the closed loop pressure and flow mode.

The reduction of the swivel angle (reduction in flow) is


achieved by connecting the control piston (4) from P -> A.

The closed loop control electronics has separate command


value inputs for the pressure and swivel angle via the central
plug (12); for the optional power limitation, the command value
is adjusted via an internal potentiometer. An external pressure
transducer can be connected via the central plug (12) or with
the ordering code F via an additional
connection (13). A position transducer with integrated electronics (7) fitted on the pump senses the actual swivel angle
valve. The sensed actual value is processed in the amplifier and
compared with the given command value.

If the higher-level controllers demand an increase of the swivel


angle (increase in flow), then the valve spool (9) must be moved from the mid position (connection of the control piston (4)
via valve port A -> T) until the swivel angle has
reached the required value. The movement of the valve spool
against the force of the spring (10) is achieved by accordingly increasing the electrical current through the proportional
solenoid (8).

Control system supply


There are three ways of supplying the pumps hydraulic
control system:
1. Internal, without pre-load valve (only possible for system
pressures > 20 bar)
2. Internal, with pre-load valve (system pressure 0 100%)
3. Remote supply via a shuttle valve automatic switchover
internal / external via a cartridge shuttle valve (take the sales
information stated within RE 30 030-01-V into account!)

11

13

1
2

12
9

10
3

705
RE 30 035/12.03

Industrial Hydraulics Bosch Rexroth AG

SYHDFEE

5/12

Operating principle: with internal supply for the control system

Actuator
(qv;p)

P
U/I

Optional

Pressure transducer
Pressure command value
0 to + 10 V

Pilot valve VT-DFPE-2X/

Flow command value


0 (10) to + 10 V

Error

U
A
B1 B

P
MB

s
U

U S
MS M1 K1

K2 T R(L)

M2

When using the HM16-1X/C13 pressure transducer:


Installed in MB (pump) in conjunction with the electronic version, actual value pressure input F
An adaptor is required to enable a HM16-1X/C13, M14x1.5 to G1/4 (Mat. No. R900695665).
The HM16, due to the installation situation, cannot be used for all of the nominal sizes (replaced by a: HM17-1X/-F with a
lengthened cable).
When using an external pressure transducer:
Installed in the B-line (preferrably in the vicinity of the actuator) and the electrical connections via the central plug
For further details see the data sheet RE 30 030-01-V, engineering guidelines

05

706
6/12

Bosch Rexroth AG

Industrial Hydraulics

SYHDFEE

RE 30 035/12.03

Technical data (for applications outside these parameters, please consult us!)
General
Drive RPM
Nominal size
Weight

1800

1800

1800

1500

NS

125

180

250

355

kg

100

115

197

220

Hydraulic
Maximum permissible operating pressure

pmax 350 bar

Minimum adjustment pressure required

pmin 20 bar

Pressure fluid temperature range

20 to + 70 C

Pressure fluid

Mineral oil (HL, HLP) to DIN 51 524

Cleanliness class to ISO-Code1)

Maximum permissible degree of contamination of the


pressure fluid is to ISO 4406 class 18/16/13

Electrical
UB 24 VDC + 40 % 5 %

Operating voltage
Operating range
Upper limiting value

UB(t)max 35 V

Lower limiting value

UB(t)min 21 V

Power requirements (in static closed loop control operation)


Nominal current

Inom. 0.6 A

Maximum current

Imax 1.25 A

Inputs
Command values (pressure and swivel angle)

Ue 0 to 10 V; RE = 100 k

Switch TD (only with ordering details A without additional


functions)
"Off"

Ue < 0.6 V

"On"

Ue > 21 V

Actual pressure value


(depending on the actual pressure input, see ordering
code)
Current input (ordering detail C)

RB 100

Voltage input (ordering details V, D, E, F)

RE 100k

Outputs
Actual values
Pressure

Ua 0 to 10 V/ 1.5 mA

Swivel angle

Ua 10 V/ 1.5 mA

Fault message L-active

Ua UB 5 V; 10 mA (short-circuit proof); error: Ua < 1 V

Power limitation H-active (only with ordering detail B


with additional function)

Ua UB 5 V; 10 mA (short-circuit proof); inactive: Ua < 1 V


Plug-in connector 12-pin, N11REFF, DIN 43 5632)

Electrical connection
Permissible ambient temperature range
Storage temperature range

1) The cleanliness class stated for the components must be


adhered too in hydraulic systems. Effective filtration prevents
faults occuring and at the same time increases the component service life.
2)

Separate order, see page 10 (electrical connections)

0 to 60 C
0 to 70 C

Note! For details regarding the environmental simulation test covering EMC (electro-magnetic compatibility), climate and mechanical loading see RE 30 035-U
(declaration regarding environmental compatibility).

1
2

L0
10
11

ULP

ULP

U(i)

L0

L0

L0

L0

R2

L0

PD

> + 11,5 V
< 11,5 V

Swivel angle
controller

xp

10 V

t = 1s

> + 3,3 V
< 3,3 V

MIN

Cable break

0F

(p ) max
pist

DIV
max

max =

Pressure
controller

(p ) max

R3

max < com

x < xp

> + 11,5 V
< 0,5 V

MIN

10 V
+ 15 V
15 V
L0

&

Switch TD 1)

Switch TD only for version without the additional function of power limitation (ordering detail A)

Only version F

1)

2)

Only for the version with the addition function of power limitation (ordering detail B)

PE

+UB
L0

Error message ( 0 V)

H
L

L0

> 80 C

PD

L0

10 V

5V3V

+ UB

Swivel angle
transducer

SYHDFEE

In switching cabinet:
bridge between
Pin 2 and 4

act 10 V to + 10 V

M0

com 0 (10) to + 10 V

pact 0 to + 10 V

pact 4 to 20 mA
or 0 to + 10 V
0 to 5 V, 1 to 10 V

HM16

2)

pcom 0 to + 10 V

Switch TD 1) or
power limitation active

L0

RE 30 035/12.03

707
Industrial Hydraulics Bosch Rexroth AG
7/12

Block circuit diagram / pin allocation of the integrated electronics for SYHDFEE (type VT-DFPE-.-2X)

05

708
8/12

Bosch Rexroth AG

Industrial Hydraulics

RE 30 035/12.03

SYHDFEE

Control loop control accuracy SYHDFEE (the stated values are only valid when the system
applicable components, as per the type code, are used)

Closed loop swivel angle control

Closed loop pressure control1)

Linearity tolerance

1.0 %

1.5 %

Temperature error

0.5 % / 10 K

0.5 % / 10 K

Hysteresis

0.2 %

0.2 %

Repeatability

0.2 %

0.2 %

1)

Without taking the pump pulsation into account

Transient function with a pressure command value jump SYHDFEE with a 360 spool
(version A)
The stated curve forms and control times can only be achieved by optimising the pressure controller.

140

140
T 95% in ms with an
attached pressure fluid
volume (pipes and
actuator)

pcom
100

100
Pressure p in bar

120

Pressure p in bar

120

80
pact

60
40
20

80

pact
pcom

60

5 10 L

200 ms

15 25 L

250 ms

For pressures up to 40
bar, the response time
values are higher.

40
20

T95% control time

T95% control time

Optimising the pressure controller for the SYHDFEE (setting the code switches)
Switch position
2)

2)

TD OFF

6.25

7.5

10

12.5

15

20

25

6.25

7.5

10

12.5

15

20

25

TD ON

7.5

10

12.5

15

20

25

30

35

12.5

15

20

25

30

35

40

45

The fluid volume of the connected pipes and actuators (in L)


Note! These are reference values and can change dependent on the nominal size and system.

709
RE 30 035/12.03

Industrial Hydraulics Bosch Rexroth AG

SYHDFEE

9/12

Transient functions with a swivel angle command value jump with a 360 spool (version A)
NS 125
100

p = 100 bar

100
80
Actual swivel value in %

Actual swivel value in %

80
60
40
20

0
NS 180

50

Time in ms

100

150

200

60
40
20

50

100

150

200

50

100

150

200

50

100

150

200

50

100

150

200

Time in ms

p = 100 bar

80

80
Actual swivel value in %

100

Actual swivel value in %

100

60
40
20

50

100

150

60
40
20

200

Time in ms

NS 250

Time in ms

p = 100 bar

80

80
Actual swivel value in %

100

Actual swivel value in %

100

60
40
20

0
NS 355

50

Time in ms

100

150

60
40
20

200

Time in ms

p = 100 bar

80

80
Actual swivel value in %

100

Actual swivel value in %

100

60
40
20

50

Time in ms

100

150

200

60
40
20

Time in ms

05

710
10/12

Bosch Rexroth AG

Industrial Hydraulics

SYHDFEE

RE 30 035/12.03

Electrical connections
Central connection

Plug-in connector without cable (assembly kit)

Plug-in connector to E DIN 43 563-B (12-pin), separate order: Plug-in connector with cable set 2 x 5 m

Material No. 00884671


Material No. 00032356

Leitungsdose mit Kabelsatz 2 x 20 m

Material-Nr. 00860399

5 4
3
10
7 11 9 2
8
1
6

Allocation of the component plug or plug-in connector and cable set

C
For type SYHDFEE V
D
E
Pin
1
2
PE
3
4
5
6
7
8
91)
10
11
n.c.

90
/.V

Allocation
+ UB
0 V L0
Earth
Fault
M0
com
act

pcom
pact
Switch TD or power limitation
Actual pressure value H
Actual pressure value L

Code
1
2

Supply cable

Green/yellow

White
Yellow
Green
Violet
Pink
Red
Brown
Black
blue
Grey

3 x 1.0 mm2

1)

Version without power


limitation (A): Switched input
Switch TD
Version with power limitation
(B): switched output power
limitation active

Signal cable
10 x 0.14 mm2;
screened
(The screen must be
attached at one end to
the control!)

For type SYHDFEEF/.V


Pin
1
2
PE
3
4
5
6
7
8
91)
10
11
n.c.

Allocation
+ UB
0 V L0
Earth
Fault
M0
com
act

pcom
pact
Switch TD or power limitation
Reserved
Reserved

Code
1
2

Supply cable

Green/yellow

White
Yellow
Green
Violet
Pink
Red
Brown
Black
Blue
Grey

3 x 1.0 mm2

Signal cable
10 x 0.14 mm2;
screened
(The screen must be
attached at one end to
the control!)

HM 16 pressure transducer connections (unit socket M12x1)

Pin Allocation
1
3
4

+ UB

View on the unit socket

0 V L0
Signal

5
2

Matching connection plug for the actual pressure value input


for version F: Plug-in connection type M12x1 (screened version, see RE 30 269)

711
RE 30 035/12.03

Industrial Hydraulics Bosch Rexroth AG

SYHDFEE

11/12

Plug removal dimension

A2

A7

A3

A1

25

Unit dimensions (in mm)

A9

A8

15 0 15

A5

T A P

A6

A4

137

NS

A1

A2

A3

A4

A5

A6

A7

A8

A9

125

276

112,5

159

177

137

160

200

20

310

180

276

116

159

177

137

160

200

20

318

250

323

144

206

212

172

224

280

24

380

355

323

144

206

212

172

224

280

24

393

Shaft ends:
NS

Wellen

= P 1)

= Z 2)

125

50

AS 14x9x80

W 50x2x30x24x9g

180

50

AS 14x9x80

W 50x2x30x24x9g

250

60

AS 18x11x100

W 60x2x30x28x9g

355

70

AS 20x12x100

W 70x3x30x22x9g

1)

Cylindrical with key way to DIN 6885

2)

Splined shaft profile to DIN 5480

05

712
12/12

Bosch Rexroth AG

Industrial Hydraulics

SYHDFEE

RE 30 035/12.03

Name plate example for a SYHDFEE combination pump

Word mark
Material short text

Material No.
Manufacturing date

Manufacturing No.

Origin identification

R123456789 FD: 39022


Rexroth MNR:
SN: 0000001
SY2HDFEE-1X/125-045/R901038404+R90119184
000120267633
Fabr. Nr

73939649

Factory

7087

Made in Germany

MINERALL
Drehrichtung

Fabrication No.
MADE ...................

Direction of rotation
Production location

For the answers to any questions regarding the combination pump, the Material No. and the Fabrication No.
are required!

Engineering guidelines
Command values must only be switched via relays having gold contacts (small voltages, small currents)
Always screen the command and actual value cables
The distance to aerial lines or radio sources must be at least 1 m
Do not lay signal cables near power cables
Supplementary guidelines regarding the SYHDFEE closed loop control system can be found in RE 30 030-01-V

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

2003 by Bosch Rexroth AG, Industrial Hydraulics, 97813 Lohr am Main


All rights reserved. No part of this document may be reproduced or stored,
processed, diplicated or circulated using electronic systems, in any form
or by means, without the prior written authorisation of Bosch Rexroth AG,
Industrial Hydraulics. In the event of contravention of the above provisions,
the contravening party is obliged to pay compensation.
The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The details stated do not release the
user from the responsibility for carrying out their own assessment and
verification. It must be remembered that our products are subject to a natural
process of wear and ageing.

713

Pump pre-load valve for the SYDFE


closed loop control system

RE 29255/09.05
Replaces: 11.00

1/4

Type SYDZ 0001

Series 1X
Maximum operating pressure 350 bar

Table of contents
Contents

6673_d

H6670_d

SYDZ 0001-1X/250V071M

SYDZ 0001-1X/250V045M

Area of application
Page

Area of application

Functional description

Ordering details

Symbol

Unit dimensions

SYDZ 0001 pump pre-load valves are used when the flow from
A10VSO variable displacement pumps with a DFE control must
be controllable at operating pressures lower than 12 bar and
only internal pilot oil is available for adjustment.
In this case the valve is mounted directly onto the SAE pressure
port of the A10VSO variable displacement pump (see RE 92711
and RE 92712).

05

714
2/4

Bosch Rexroth AG

Hydraulics

SYDZ 0001

RE 29255/09.05

Functional description
The pre-load function is only effective within the pressure range of up to 20 bar. If the operating pressure in port P1 exceeds
30 bar, the pre-load valve (1) is fully open. In order to limit the
maximum pressure, a factory-preset pressure relief valve (2) is
integrated into the pre-load valve (see ordering details). In addition, an integrated check valve (3) allows the pressure to be
controlled in the range < 20 bar.

Attention!
The pressure relief function is purely a safety function and
is therefor not suitable for continuous use!
The system must be bled during commissioning.

Symbol
1

P1

MP1

20 bar

Pre-load valve

Pressure relief valve

Check valve

Bleed screw

PP

Ordering details (only for separate order of the pre-load valve!)


SYDZ 0001

1X

Series 10 to 19
= 1X
(10 to 19: unchanged installation and connection dimensions)
Pressure limitation 150 bar
Pressure limitation 175 bar
Pressure limitation 200 bar
Pressure limitation 250 bar
Pressure limitation 300 bar

= 150
= 175
= 200
= 250
= 300

*
Further details in clear text

M=

V028 =
V045 =
V071 =
V140 =

Seals suitable forl


(HL, HLP) to DIN 51524
Pump type and nominal size
A10VSO NG 18/28
A10VSO NG 45
A10VSO NG 71
A10VSO NG 100/140

715
Hydraulics Bosch Rexroth AG

SYDZ 0001

RE 29255/09.05

3/4

Unit dimensions
NG 18, 28 and 45
K
27A/F

T1)
MP1
E

P1

PP

M
A

Not included within the scope of supply:


4 off valve fixing screws

30

M10 x 120-10.9 DIN 912; MA = 50 Nm


for NS 18/28 and 45
L

1)

NS

18/28

45

75

80

115

115

104

104

60,5

60,5

30

29

14

15

30

33

34

34

22,2

26,2

47,6

52,4

4 x 10,5

4 x 10,5

PP

SAE 3/4

SAE 1

P1

G 1/2

G 3/4

M8 x 1

M8 x 1

MP1

G 1/4

G 1/4

T1)

G 3/8

G 3/8

NS

71

100/140

85

85

150

147

134

131

94

91

55

52

24

24

56

56,5

The pipework must be done in the L (light series) version.

NG 71, 100 and 140


P1
NG 100/140
SAE connection

B
C

1)

P1

MP1

Not included within the scope of supply:


M
A

for NS 71

L
A
1)

P
PP

K
41 A/F

4 off fixing screws

44

48

45

45

30,2

31,8

58,7

66,7

4,5

4,5

4 x 10,5

4 x 15

PP

SAE 1 1/4 SAE 1 1/4

M10 x 150-10.9 DIN 912; MA = 55 Nm

P1

G1

SAE 1 1/4

for NS 100/140

G 1/8

G 1/8

4 off S.H.C.S.

MP1

G 1/4

G 1/4

M14 x 150-10.9 DIN912; MA = 100 Nm

T1)

G 3/4

G 3/4

The pipework must be done in the L (light series) version.

05

716
4/4

Bosch Rexroth AG

Hydraulics

SYDZ 0001

RE 29255/09.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
Telefax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

717

3/3 proportional directional valves,


direct operated, with electrical
position feedback as pilot valves for
the SYDFE. control system

RE 29016/06.05
Replaces: 06.02

1/12

Type VT-DFP.

H6633

Type VT-DFP-.-2X/... with cable


socket (separate order)

Component series 2X
Maximum operating pressure 315 bar

Table of contents
Contents

H6198

Type VT-DFPE-.-2X/...

Features
Page

Pilot valve for the pressure and flow control system SYDFE.

Features

Ordering code

For the closed-loop control of the swivel angle of a type


A10VSODFE. variable displacement pump

Technical data

Actuation by a proportional solenoid with electrical feedback

Electrical connection: Type VT-DFP...


(for external analogue control electronics)
Electrical connection: Type VT-DFPE...
(with integrated control electronics)
Electrical connection: Type VT-DFPC...
(with integrated digital control electronics)
Unit dimensions

Control electronics:
4
5 and 6
7
8 and 9

Example of nameplate for a 3/3 proportional directional valve 10

VT-DFP external analogue amplifier VT 5041-2X


(in conjunction with control system SYDFE1 according to
RE 30024)
VT-DFPE integrated, analogue (in conjunction with control
system SYDFEE according to RE 30030)
VT-DFPC integrated, digital with CAN bus interface
(in conjunction with control system SYDFEC according to
RE 30027)

05

718
2/12

Bosch Rexroth AG

Hydraulics

VT-DFP.

RE 29016/06.05

Ordering code
VT-DFP
For external
control electronics
With integrated analogue
control electronics
With integrated digital
control electronics

2X G24 K0

= No code

... =

=E

=A
=B
=C

Actual pressure value


input
No code =
for VT-DFP
Only for VT-DFPE and VT-DFPC
C=
Current input 4 20 mA
V=
Voltage input 0 10 V
D=
Voltage input 0 5 V
E=
Voltage input 1 10 V
F=
Voltage input 0.5 5 V 2)

Component series 20 to 29
= 2X
(20 to 29: unchanged installation and connection dimensions)
24 V DC voltage

= G24

Component plug (without cable socket)

= K0 1)

Mounting orientation:
VT-DFP...
Mounting orientation of position transducer / solenoid
radially to the pump axis
Folded through 90 towards the subplate
with counter-clockwise direction of rotation of the pump
Folded through 90 towards the subplate
with clockwise direction of rotation of the pump
VT-DFPE... and VT-DFPC
Mounting orientation of position transducer / solenoid
radially to the pump axis
Folded through 90 towards the subplate
with counter-clockwise direction of rotation of the pump
Folded through 90 towards the subplate
with clockwise direction of rotation of the pump

=0
=1

0=
1=

=2

0=
=0

2)

The component plug is determined by the control electronics


(see technical data and electrical connection)!
Cable sockets separate order, see pages 4, 5 and 6.
Connection via cable socket M12

Additional function
for VT-DFP
for VT-DFPE
Without power limitation
With power limitation
Power limitation via analogue input (0-10 V)
Pressure controller that can be switched off (High signal)
for VT-DFPC
Standard

No code =
=1
=2

Options
for VT-DFP
for VT-DFPE
Standard electronics with leakage compensation
Standard electronics without leakage compensation
for VT-DFPC
Standard

No code =

A=
B=
C=
D=
A=

1)

Further details
in clear text
e.g. SO variant

V=
FKM seals
Suitable for mineral oils (HL,
HLP) to DIN 51524 and phosphate esters (HFD-R)

=C

Spool variant
Standard
2-groove spool
4-groove spool

719
RE 29016/06.05

Hydraulics Bosch Rexroth AG

VT-DFP.

3/12

Technical data (for applications outside these parameters, please consult us!)
General
Component version

VT-DFP

VT-DFPE

VT-DFPC

Storage temperature range

20 +70

0 70

0 70

Ambient temperature range

20 +60

0 60

0 50

Weight

kg

1.96

2.25

2.25

Hydraulic
Hydraulic fluid

Mineral oil (HL, HLP) to DIN 51524;


phosphate esters (HFD-R)
other hydraulic fluids on enquiry

Hydraulic fluid temperature range

C 20 +70
mm2/s

Viscosity range
Degree of contamination
Operating pressure

20 380
Max. permissible degree of contamination of hydraulic fluid to
NAS 1638 class 7.

Ports A, P

bar 315

Port T

bar 100

Electrical
Solenoid coil resistance

2.1 3.2

Coil resistance

between ports 1 and 2

approx. 113

(at 20 C)

between ports 3 and 4

approx. 101

VT 5041-2X

integrated, analogue

integrated, digital

Control

Note:

Further information on control systems:

For details regarding environment simulation testing in the


fields of EMC (electromagnetic compatibility), climate and
mechanical stress (declaration on environmental compatibility),
see:

Type SYDFE1 to RE 30024 in conjunction with VT-DFP

VT-DFP:

Type SYDFEE to RE 30030 in conjunction with VT-DFPE


Type SYDFEC to RE 30027 in conjunction with VT-DFPC

RE 30024-U

VT-DFPE:

RE 30030-U and

VT-DFPC:

RE 30027-U

05

720
4/12

Bosch Rexroth AG

Hydraulics

RE 29016/06.05

VT-DFP.

Electrical connection: Type VT-DFP... (for external analogue control electronics)


Solenoid
Cable socket, 3-pin Z4 M SW-BG to DIN EN 175301-803
Separate order stating material no. R901035403

Connection to cable socket

53

27,5

27,5

22,5

Connection to component
plug

PE

36

PE

to amplifier

Pg11
30

30

Inductive position transducer


Coil connection

Component plug

Connection to plug-in connector


(top view of component plug)

1
Signal
4 2
1 3

Reference

Supply

Shield1)

Cable socket, 4-pin Pg7-G4W1F/Pg7 SW


Separate order stating material no. R900023126
37

7,8

23
1)

Notes on the shield and recommendations with regard to


the cable type can be found in the engineering notes on the
complete system system SYDFE1-2X/ (see RE 3002401-B)!

Pg7

15

16

Amplifier

721
Hydraulics Bosch Rexroth AG

VT-DFP.

RE 29016/06.05

5/12

Electrical connection: Type VT-DFPE... (with integrated control electronics)


Central connection

Socket without cable (kit)

Material no. R900884671

Cable socket to DIN EN 175201-804 (12-pin),

Socket with cable set 2 x 5 m

Material no. R900032356

separate order:

Socket with cable set 2 x 20 m

Material no. R900860399

X:

5
6

4
3

10

11
8

9
1

90

Pin assignment of the component plug or cable socket and cable set
C
V
for type VT-DFPE.. /.V
D
E
Pin

Assignment

+ UO
0 V
= L0

PE

Ground

green/yellow

1)

Code

(A):
Supply cable
3 x 1.0 mm2

Fault

white

M0

yellow

comm

green

Signal cable
10 x 0.14 mm2;

act

violet

pcomm

pink

pact

red

9 1)

Switch TD or power limiter

brown

10

Actual pressure value H

black

11

Actual pressure value L

blue

n. c.

Switching input Switch TD


Variant with power limiter

Variant without power limiter

(B):
Switching output
Power limiter active

shielded
(shield must be connected to
the control on one end!)

grey

05

722
6/12

Bosch Rexroth AG

Hydraulics

VT-DFP.

RE 29016/06.05

Electrical connection: Type VT-DFPE... (with integrated control electronics) continued


for type VT-DFPE...F/.V
Pin

Assignment

Code
1

+ UO
0 V
= L0

PE

Ground

green/yellow

Supply cable
3 x 1.0 mm2

Fault

white

M0

yellow

comm

green

Signal cable

act

violet

10 x 0.14 mm2;

pcomm

pink

shielded

pact

red

(shield must be connected to


the control on one end!)

9 1)

Switch TD or power limiter

brown

10

Reserved

black

11

Reserved

blue
grey

n. c.

Connection of pressure transducer HM 16 (component socket M12x1)


Pin
1

+ UO

Reference

Signal

Assignment
Top view of component
socket

5
2

Suitable connecting plug for actual pressure value input for version F: Cable plug type M12x1 (shielded version)

723
Hydraulics Bosch Rexroth AG

VT-DFP.

RE 29016/06.05

7/12

Electrical connection: Type VT-DFPC... (with integrated digital control electronics)


Central connection

Socket without cable (kit)

Material no. R900884671

Cable socket to DIN EN 175201-804 (12-pin),

Socket with cable set 2 x 5 m

Material no. R900032356

separate order:

Socket with cable set 2 x 20 m

Material no. R900860399

X:

5
6

4
3

10

11
8

9
1

90

X1: Assignment of component plug or cable socket and cable set


for type VT-DFPC.. /V
Pin

Assignment

Code

+ UO
0 V
= L0

2
PE

Ground

green/yellow

Supply cable
3 x 1.0 mm2

Fault

white

M0

yellow

U in 2 (AI2)

green

Signal cable

UOUT2

violet

10 x 0,.4 mm2;

U in 1 (AI1)

pink

shielded

UOUT1

red

(shield must be connected to


the control on one end!)

Digital IN1 (DI1)

brown

10

Actual pressure value High

black

11

Actual pressure value Low

blue
grey

n. c.
X2: Connection of pressure transducer HM16

and serial interface (RS232) (component socket M12x1)


Pin
1

Assignment (PT)
+ UO

Pin
2

Assignment
RS232

3
Top view of component plug

RxD (RS232)

5
2

Reference L0

Suitable connecting plug for actual pressure value input for version F: Cable plug type M12x1 (shielded version)
X3: Connection to CAN bus and digital input 2 (DI2),
shielded (component plug M12x1)
Pin

Assignment

Reserved

Digital IN2 (DI2)

Pin

3
4

Assignment

CAN-High

CAN-Low

Top view of component


socket

5
2
1

21

05

724
8/12

Bosch Rexroth AG

Hydraulics

VT-DFP.

RE 29016/06.05

Unit dimensions (nominal dimensions in mm)


Type VT-DFP-.-2X/...

4
15

55,5

46,8

T A

32

35,7

85
132

80

10

(45)

220

7,5

34

14

16 20

15

34

47
30

15

45

71

30

T A P
73

Type VT-DFPE.-.-2X/...

13

12
60

10

136,5

46,8

T A

32

126,5

121,5

81

80

(45)

217,5

71
15

34

7,5

0,01/100mm
Rzmax 4
45

30

6789

EF012

ABCD
345

Required surface quality


of the valve mounting face
Valve fixing screws (all types)
4 off M6 x 40 DIN 912-10.9, tightening torque MT = 9 Nm
(separate order)

For explanation of items, see page 9

725
RE 29016/06.05

9/12

Hydraulics Bosch Rexroth AG

VT-DFP.

Unit dimensions (nominal dimensions in mm)


Type VT-DFPC.-.-2X/...

13

15

12

121,5

11

10

100

11

100

10

46,8

T A

32

136,5

81

80

(45)

217,5
71
15

34

34
16 20

47
30

45

30

6789

EF012

ABCD

15

7,5

14

T A P

345

73

Valve housing

Proportional solenoid with position transducer

Cable sockets, separate order, see pages 4, 5 and 6

Space required to remove cable socket

R-rings 9.8 x 1.5 x 1.7 (ports P, A, T)

Solenoid rotated through 90 (stroke mounting orientation 2)

10

Connection of pressure transducer HM 16


(only with VT-DFPE./F or VT-DFPC)

11

Connection to CAN BUS, shielded, component plug


M12, 5-pin

12

Installation space required for plug-in connection (HM 16)

13

Dimension for version VT-DFPE...F or VT-DFPC


(connection for HM 16 or CAN BUS)

Connection of rotary angle sensor VT-SWA-1-1X

14

Machined valve mounting surface

Nameplate

15

Integrated control electronics

Space required for CAN connection (plug-in connection to be provided by customer)

05

726
10/12

Bosch Rexroth AG

Hydraulics

VT-DFP.

RE 29016/06.05

Example of nameplate for a 3/3 proportional directional valve

MNR: R900724226

SN: 0000003

FD: 58406

V T- D F P E - A - 21/ G 2 4 K 0 / 2 A 1/ V
000120693931

7087
5

4
Made in Germany

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

Material no.

Serial no.

Date of production

Production no.

Type designation

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

727
RE 29016/06.05

VT-DFP.

Hydraulics Bosch Rexroth AG

11/12

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

728
12/12

Bosch Rexroth AG

Hydraulics

VT-DFP.

RE 29016/06.05

Notes

Bosch Rexroth AG
Hydraulics
Zum Eisengieer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax
+49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specifications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.

729

Digital controller amplifier for


operating axial piston pumps of type
A4VS with HS4 control

RE 30028/10.04
Replaces: 08.04

1/12

Type VT-VPCD

Series 1X

HAD7190/04

Table of contents
Contents
Features

Features
Page
1

Features of the VT-VPCD digital control amplifier

Ordering code

Functional description, section of the A4VS axial piston pump


with HS4 control
3
Circuit variants of the HS4 control
Technical data, electrical

5 and 6
7

The HS4 control is used for the electrohydraulic closed-loop


control of swivel angle and pressure and for limiting the power of
variable displacement axial piston pumps.
The closed-loop control system with HS4 control consists of the
following assemblies:
A4VSHS4 axial piston pump with built-on 4WRE6-2X/822
proportional valve, including position transducer for acquiring
the swivel angle and valve travel (for technical data and ordering code, see RE 92050 for the open circuit, RE 92100 for the
closed circuit as well as RE 92076)

Pin assignment of the D-SUB socket on the front panel

Steady-state characteristic curve

Transfer function in the case of a swivel angle


command value step change

Recommended pressure transducer for acquiring the system


pressure is HM17

Technical data, electrical

VT-VPCD amplifier card for implementing the electrical functions required for the HS4 control

Block circuit diagram / pin assignment

10

Pin assignment of the male connector

11

Engineering / maintenance notes / supplementary information 12


Unit dimensions

12

05

730
2/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VPCD

RE 30028/10.04

Features of the VT-VPCD digital control amplifier


The amplifier can be parameterised via a serial interface. User
data can be exactly reproduced and are protected against unintentional or unauthorised adjustment.

Required accessories:
PC program BODAC: Ordering code of the CD: SYSHACD-BODAC-01 (R900777335) or free download on the
Internet at www.boschrexroth.com/hacd

Digital inputs for calling pre-set parameters


Ramp times for swivel angle and pressure command values
Analogue inputs for command and actual values

Interface cable: Cable set VT-HACD-1X/03.0/


HACD-PC (R900776897) or commercial 1:1 cable

Enable input and collective fault output

Further information:

Oscillators/demodulators for two inductive measuring systems

Instructions for the installation of the VPCD can be found in


the on-line help.

Clocked, current-regulated output stage

Operating instructions for BODAC

Switched-mode power supply unit for internal supply


voltages

Suitable card holders:

LEDs that signal functions and states

19 rack types VT 19 101, VT 19 102, VT 19 103 and VT 19


110 (see RE 29768)

2 measuring sockets that can be configured via display and/


or Bodac

Enclosed card holder type VT 12 302 (see RE 30103) (preferred)

Serial interface RS 232


Selection of sizes (40 to 1000) and parameterisation via
BODAC

Open card holder type VT 3002-2X/64G (see RE 29928)


For installation in control cabinet only!

Valve position controller

Connection adapter VT10812-2X/64G (see RE 30105)

Pressure controller with underlaid swivel angle controller


Parameterisable power limitation
Leakage compensation
Master-slave capability
Mooring capability
Oscilloscope function

Ordering code

VTVPCD

1X V0

Digital amplifier for controlling variable displacement axial piston pumps with HS4 control

1=
0=

Series 10 to 19
= 1X
(10 to 19: unchanged installation and connection dimensions)
Basic component

1=
= V0

With valve output stage


Without bus interfacing
With display

731
RE 30028/10.04

Industrial Hydraulics Bosch Rexroth AG

VT-VPCD

3/12

Functional description, section of the A4VS axial piston pump with HS4 control
An electrically controlled proportional valve (1) controls the
swivel angle and pressure and limits the power of the A4VS...
variable displacement pump. This valve determines the position
of the swashplate (3) via the actuating piston (2) of the pump.
When the pump does not rotate and the actuating system is
depressurised and no enable is present, a spring-centring feature holds the swashplate in the zero swivel angle position.
The position of the swashplate is established by an inductive
position transducer (4), which acquires the actual pressure
value with the help of a pressure transducer. Both actual values
are fed to the controller and interlinked by the software.
The actual power value is obtained from the product of actual
pressure value and actual swivel angle value. The controller
software ensures with a minimum value generator that always
the controller is active that is assigned to the relevant working
point.

In the steady-state condition, i.e. swivel angle command value


is equal to the actual swivel angle value, the power command
value is equal to the actual power value or the pressure command value is equal to the actual pressure value, the control
spool of the valve is in the central position.
If higher-level controllers demand, for example, an increase in
the swivel angle (corresponds to an increase in flow), the valve
spool must be shifted from the central position until the swivel
angle has reached the required value.
The sectional drawing shows the A4VS... variable displacement
pump with HS4 control; proportional valve (1) is controlled by
means of the VT-VPCD amplifier card.
Note on the HS4 control:
The 4WRE6-2X/822 proportional valves are shown with reference to a clockwise driven pump, i.e. when the valve is deenergised, the pump swivels to = 0 with version A4VSO
or to = 100 % with version A4VSG.

05

732
4/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VPCD

RE 30028/10.04

Functional description
The amplifier card is designed as double-sided printed circuit
board in Euro-card format 100 x 160 mm. The assembly includes a switched-mode power supply unit [1], which generates all the internally required voltages.
The central unit of the amplifier is a microcontroller, which controls the entire sequence and realises the functions of the controller. Amplifier-specific data (configuration, command values,
parameters) are saved in a non-volatile FLASH.

The switching outputs are configured using BODAC. The following functions can be selected:
Swivel angle control active

DO1

Pressure control active

DO2

Power limitation active

DO3

Swivel angle in the accuracy window

DO5

Pressure in the accuracy window

DO6

Four binary-coded, digital inputs are used for calling parameter


sets (command values) from the memory, in which a maximum
of 16 sets can be saved. A call-up activates a command value
for the swivel angle, pressure and power limitation as well as
ramp times for swivel angle and pressure.

The test output (b26 or measuring socket X1) is also configured with the help of BODAC. It serves for the analogue output
of internal variables.

Further control inputs assume the following functions:

The closed-loop control is activated by setting the enable input. If no command value call-up is activated, parameter set 0
is set.

"Command valid": Enable of the parameter set addressed


by the current call-up (H-active)
"Enable":

Activation of closed-loop control


(H-active)

Note:

H-active = High active (level 15 V to UO)


L-active = Low active (level 0 V to 2 V)
L/H-edge = Low high edge

The analogue command values for swivel angle, pressure and


maximum power are fed forward via three differential inputs [3].
When a positive swivel angle command value is applied, the
pump swivels to the left (= direction of flow P > B). The digital call-up command values are added to the analogue command values and the sum of both command values is fed via
the associated ramp generator to the input of the controller.
The output signal of the controller controls the output stage [6]
of the amplifier in dependence upon the differences between
command/actual values.
The position of valve spool [11], the swivel angle of the variable displacement pump [12a/b] 12a, A4 housing pump; 12b,
A2 housing pump [12] and the system pressure [13] are measured and fed via evaluation electronics [7] to the closed control
loop.

Enable and fault messages

A fault logic detects the following faults:


Cable break or short-circuit in actual valve value acquisition
Cable break or short-circuit in actual swivel angle value
acquisition
Cable break of the pressure transducer (current interface
only)
System deviation (difference between swivel angle command
value and actual swivel angle value)
Faults are signalled at output d22. The Ok signal is withdrawn, the signal level is 0 V.
The occurrence of a fault is indicated on the display.
Parameterisation and diagnosis
The selection of the pump size, the activation or deactivation of
leakage compensation and sequence control and the configuration of switching outputs take place via the serial interface at
the D-sub socket at the front using BODAC [2].
Indicator elements and measuring sockets
The freely configurable measuring sockets X1/X2 at the front
panel serve for signalling process signals. For their configuration, refer to the on-line help.

Various modes are provided for closed-loop pressure control:


Depending on the configuration, the pressure controller works
with one or two pressure sensors.
Open circuit:
1 sensor
Closed circuit:
2 sensors
1 pressure sensor, optionally current or voltage, for the open
circuit
2 pressure sensors, optionally current or voltage, for the
closed circuit
In the closed circuit, both pressure sensors are evaluated. As
soon as the control electronics is in the closed-loop pressure
control mode, the higher of the two pressures determines control characteristics. Here, the pressure controller can swivel
the pump also to the opposite side or beyond its actual swivel
angle command value in order to correct a system deviation
(pressure command value - actual pressure value).

The following states are signalled by LEDs:


LED power (green):

internal supply voltage

LED Ok (green):

OK message

LED select 1, 2, 4, 8 (yellow): Indicates the requested command value call-up, which is
activated by DI 6.
[ ] = Cross-reference to the block circuit diagram

733
RE 30028/10.04

Industrial Hydraulics Bosch Rexroth AG

VT-VPCD

5/12

Circuit variants of the HS4 control


A4VSO - open circuit (see RE 92050 and RE 92076-HS4)

u
p

b
B

i\u

A
Sp

VT-VPCD

Rkv
B1 B

MB

Command
values

MS

R4 R3 R2

K1

K2

R(L)

R5 R6 R7

05

734
6/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VPCD

RE 30028/10.04

Circuit variants of the HS4 control


A4VSG - closed circuit (see RE 92100-HS4K)

p
i
p
i\u
B

u
VT-VPCD

Msp

b
B

MA

MB

Command
values

1
Sp
Rkv

U
s

Note:
Pump type A4VSGwithout short-circuit valve (1)
swivels to the right (Qmax)
when the valve is de-energised and actuating pressure is applied.

R4 R3 R2

K3

K2

R(L)

R5 R6 R7

735
RE 30028/10.04

Industrial Hydraulics Bosch Rexroth AG

VT-VPCD

7/12

Technical data, electrical (for applications outside these parameters, please consult us!)
4WRE6-2X/822 valve for HS4 control
Imax 2.5 A

Current consumption per solenoid current


Control current at constant swivel angle

Ia Solenoid a = 450 mA
Ib Solenoid b = 700 mA

Solenoid coil resistance:


Cold value at 20 C

R 2.7

Max. hot value

R 4.5

Electrical connection

Plug-in connection in accordance with DIN EN 175301-803

Type of protection to DIN 40 050

IP 65

Position transducer for 4WRE valve


Carrier frequency

f 5 kHz

Coil resistance (at 20 C):


between connections 1 and 2

R 113

between connections 3 and 4

R 101

Electrical connection

GM 209 plug-in connector

Type of protection of plug-in connection to DIN 40 050

IP 65

Swivel angle transducer


Carrier frequency

f 5 kHz

Coil resistance (at 20 C):


between connections 1 and 2

R 110

between connections 3 and 4

R 560

Electrical connection

Plug-in connection to DIN 43 650-BFZ-Pg9

Type of protection of plug-in connection to DIN 40 050

IP 65

Pin assignment of the D-SUB socket on the front panel

5
9

GND

Send data (RS 232)


Receive data (RS 232)
6
1

05

736
8/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VPCD

RE 30028/10.04

Steady-state characteristic curve

Swivel angle
Actual
( )
act

= 100 % actual power

Swiel angle in %

Desired
power

Operating pressure in bar

Act. pressure

Transfer function in the case of a swivel angle command value step-change


Example: Size 250, actuating pressure p = 125 bar

Actual swivel angle value in %

80
60
40
20

50

100
Time in ms

150

200

Actual swivel angle value in %

100

100

80
60
40
20

50

100

150

Time in ms

200

737
RE 30028/10.04

Industrial Hydraulics Bosch Rexroth AG

VT-VPCD

9/12

Technical data, electrical (for applications outside these parameters, please consult us!)
Operating voltage

UO 24 VDC + 40 % 10 %

Operating range
- Upper limit value

UO(t)max 35 V

- Lower limit value

UO(t)min 21 V

Current consumption
Nominal resistance of solenoid (20 C)
Oscillator frequency
(position transducer of valve spool, swivel angle)

Imax < 2 A
R 2
f approx. 5 kHz

Analogue command value inputs:


for swivel angle, pressure and power selection

U 0 - 10 V

Range

U 10 V

Input resistance

Ri 100 k

Resolution

5 mV for the range of 10 V; 2.5 mV for the range of 0...10 V

Non-linearity

< 10 mV

Analogue actual pressure value input:


Range
Actual input value

4...20 mA or 0...10 V
Ri 100 voltage drop across actual pressure value input at 4 mA
approx. 1.7 V, 20 mA approx. 3.5 V

Current loss

0.15 % (at 500 between Pin AI x - and 0 V)

Resolution

5 A [12 bits]

Analogue outputs
A0 1 configuration as voltage output
Output voltage
Load

U 10 V
Rmin 1 k

Resolution

1.25 mV (14 bits)

Residual ripple content

15 mV (without noise)

A0 2 resulting swivel angle command value


Output current

Imax 10 mA

Load

Rmin 1 k

Resolution
Residual ripple content
Reference voltage:

10 mV (11 bits)
25 mV (without noise)
U 10 V
Imax 30 mA

Residual ripple content


Scanning rate

< 20 mV
T 2 ms

Serial interface

RS 232 (front panel), D-sub socket, 9-pin

Type of connection

64-pin male connector, DIN 41 612, form G

Card dimensions

Euro-card 100 x 160 mm, DIN 41 494

Front panel dimensions:


- Height

3 HE (128.4 mm)

- Width soldering side

1 TE (5.08 mm)

- Width component side


Permissible operating temperature range

7 TE (35.56 mm)
0 to 50 C

Storage temperature range

- 20 to + 70 C

Weight

m 0.2 kg

Note:
For deatils regarding environment simulation testing in the fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 30028-U (declaration on environmental compability).

05

b14

b20

GND X1 X2

- U SS

b28

b30

b32

d22
d20
d26
z22
z26
z28

b26

d32

b22
b24

f26
f24
f22
f20
z10

z18
z16
z14
z12

b6
b8

+ USS

z8

UB

12b

b6
b8

UB

b24

I(U)
pB

I(U)
pA

13b

Analogue GND

Reference voltage + 10 V
Reference voltage 10 V

OK: Ready for operation


DO1: Swivel angle controller active
DO2: Pressure controller active
DO3: Power limiter active
DO5: | comm - act|<window
DO6: | pcomm - pact|<window

Test output

b28

+ 10 V b32

I(U)
p b22

13a

12a

b10
b12

11

Resulting swivel angle


command value comm

1
3
4
2

1
3
4
2

10

6 Current-regulated output stage


7 Oscilator/ demodulator
8 Voltage output

2 Serial interface

3 Voltage or current input

4 Level converter

13b Pressure sensor current (closed current)

12a Pump swivel angle position transducer (E-Z020-409)

OK
O1
O2
O3
O5
O6

13a Pressure sensor current (open current)

RS 232

z6

z10

12b Pump swivel angle position transducer (MCP-40/4742)

CONTROL

PID

z4

z2

11 Valve position transducer

MAX

10 Proportional valve

DC
DC

16

2
3

p
P

MIN

PI

9 Output driver

pmax

P max

LIMIT

VT-VPCD

5 Microcontroller

z32

z30

z20

Industrial Hydraulics

1 Power supply unit

System ground

Enable

d18

I1
I2
I3
I4
I5
I6

d12

d10

d2
d4
d6
d8

Bosch Rexroth AG

DI1 comm. call-up 1


DI2 comm. call-up 2
DI3 comm. call-up 3
DI4 comm. call-up 4
DI5 slave mode
DI1 to 5 valid

b4

b2

U
+

Swivel angle command


value comm (slave)

U
+

Swivel angle command


b16
value comm (master)

Pressure command
value Pcomm

b18

f10

f8

Power command
value Pcomm

10/12

738
RE 30028/10.04

Block circuit diagram /pin assignment

739
RE 30028/10.04

Industrial Hydraulics Bosch Rexroth AG

VT-VPCD

11/12

Pin assignment of the male connector


Row d

Row b

Pin

Description

VT-VPCD-1-1X

Pin

Description

DI 1

Comm. 1 H-active

DI 2

Comm. 2 H-active

DI 3

8
10

VT-VPCD-1-1X

AI1+

Swivel angle command value for slave


(for slave operation)

Comm. 4 H-active

AI1-

Reference of swivel angle command value

DI 4

Comm. 8 H-active

AI2+

Actual pressure value (A) + (U/I)

DI 5

Slave mode H-active

AI2-

Actual pressure value (A) + (U/I) reference

AI3+

Actual pump swivel angle value 12b

12

DI 6

Comm. valid H-active

10

14

DI 7

n. c.

12

AI3-

16

DI 8

n. c.

Reference of actual pump swivel angle value 12b

18

DI 9

Enable H-active

14

AI4+

Swivel angle command value +

20

DO 1

Swivel angle controller active

16

AI4-

Swivel angle command value + reference

22

OK

18

AI5+

Pressure command value +

24

Data +

n. c.

20

AI5-

Pressure command value + reference

26

DO 2

Pressure controller active

22

AI6+

Actual pressure value (B) + (U/I)

28

Data -

n. c.

30

AO 1

Valve command value

32

AO 2

Resulting swivel angle command value for master-slave operation

OK output H-active

24

AI6-

Actual pressure value (B) + (U/I) reference

26

AO 3

Test output (measuring socket X1)

28

AGND

30

REF-

Reference voltage - 10 V

32

REF+

Reference voltage + 10 V

Analogue GND

re 12b, see block circuit diagram

Row z

Row f

Pin

Description

Pin

Description

M1+

VT-VPCD-1-1X
Solenoid A+

DO 7

n. c.

M1-

Solenoid A-

Clk +

n. c.

M2+

Solenoid B+

Clk -

n. c.

VT-VPCD-1-1X

M2-

Solenoid B-

AI7+

Power command value +

10

Shield

Shield

10

AI7-

Power command value + reference

12

L 1O-

Valve position transducer, supply -

12

Ua2 and AI8+

n. c.

14

L 1l-

Valve position transducer, actual value -

14

/Ua2 and AI8-

n. c.

16

L 1l+

Valve position transducer, actual value +

16

Ua0

n. c.

18

L 1O+

Valve position transducer, supply +

18

/Ua0

n. c.

20

LVDT 2 OUT LVDT 2 IN -

Pump position transducer, act. value - 12a

LVDT 2 IN +

Pump position transducer, act. value + 12a

20

System ground System ground

22

DO 3

Power limiter active

22

24

DO 4

n. c.

24

26

DO 5

| acomm - aact | < window

26

28

DO 6

| pcomm - pact| < window

28

n. c.

30

UO

Supply voltage

30

n. c.

32

LO

Ground

32

n. c.

Pump position transducer, supply - 12a

LVDT 2 OUT + Pump position transducer, supply + 12a

re 12b, see block circuit diagram

05

740
12/12

Bosch Rexroth AG

Industrial Hydraulics

VT-VPCD

RE 30024/10.04

Engineering / maintenance notes / supplementary information


The amplifier card may only be plugged or unplugged when disconnected from the power supply!
Measurements on the card may only be taken using instruments with Ri > 100 k!
Use relays with gold-plated contacts for passing on analogue command values and digital call-ups (small voltages, small currents)!
Always shield command value and actual value cables; leave shield open on one end and connect it to the system ground on
the card side!
Recommendation: Up to 50 m length, use cable type LiYCYCY 1.5 mm2 for solenoid cables; as position transducer cable, use
type LiYCYCY 0.5 mm2, shielded. For greater lengths, please consult us!
The distance to aerial lines or radio sources must be at least 1 m !
Do not lay solenoid and signal cables near power cables !
Commissioning and programming of the amplifier card is described in detail in product description and adjustment instructions
RE 30028-B.
Note: Electrical signals (e.g. signal fault message) brought out via control electronics must not be used for switching safetyrelevant machine functions!
(See also European standard Safety requirements for fluid power systems and components hydraulics", prEN 982)

Unit dimensions (dimensions in mm)

UP
DOWN

100

3HE (128,4)

ESC

X1 X2

I1
I2
I3
I4
I5
I6
I7
I8

122

ENT

89

OK

O1
O2
O3
O4
O5
O6
O7

8TE (40,3)

165

195,5

Bosch Rexroth AG
Industrial Hydraulics
Zum Eisengiesser 1
97816 Lohr am Main, Germany
Telephone +49 (0) 93 52 / 18-0
Fax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de

This document, as well as the data, specications and other


information set forth in it, are the exclusive property of Bosch Rexroth
AG. Without their consent it may not be reproduced or given to third
parties.
The data specied above only serve to describe the product. No
statements concerning a certain condition or suitability for a certain
application can be derived from our information. The given information
does not release the user from the obligation of own judgement and
verication. It must be remembered that our products are subject to a
natural process of wear and aging.

741

RE 30 241/02.03
Replaces: 11.02

External control electronics for the DFE1


control of A10VSO axial piston pumps

H/A/D 6639

Analogue amplifier, configurable


Type VT 5041
From series 25

Type VT 5041-2X/.

Table of contents
Contents
Features
Ordering code
Functional description
Block circuit diagram / pin assignment
Technical data
Indicator / adjustment elements
Unit dimensions
Supplementary information

Features
Page
1
2
2
3
4
5
6
6

Card holder:
Type VT 3002-2X/32, see RE 29 928
Single card holder without power supply unit
Power supply unit:
Type VT-NE32-1X, see RE 29 929
Compact power supply unit 115/230 VAC > 24 VDC
Output 1 (60 VA) for supplying amplifier card type VT 5041
Output 2 (25 VA) for supplying pressure transducers;
e.g. types HM 12 or HM 13, see RE 29 933

Integral part of the SYDFE1 pressure and flow control system


(series 1X and 2X) for controlling A10VSO... axial piston units
with DFE1 control
Implementation of the electronic functions of the DFE1 control;
pressure and swivel angle control; optional power limiter
Circuitry of the pressure controller can be matched to existing
hydraulic fluid volumes (actuator plus lines)
Differential amplifier inputs
Controller for valve spool position
Minimum value generator for pressure and swivel angle
controller
Self-clocking output stage
Pressure-related leakage compensation (can be switched off)
Polarity reversal protection for power supply
Switchable actual pressure value input (current, voltage, range)
LED lamps on the front panel:
Error / no enable H1
Internal supply voltage H2
Indicator instrument for actual swivel angle value on the front
panel (optional)
Power limiter with internal or external command value
feedforward (optional)

05

2003
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event
of contravention of the above provisions, the contravening party is obliged to pay compensation.

VT 5041

1/6

RE 30 241/11.02

742

Ordering code

VT 5041 2X/

Further details
in clear text

External control electronics for the DFE1 control of


A10VSO axial piston pumps
Series 25 to 29
(25 to 29: unchanged technical data
and pin assignment)

/*

= 2X

Additional functions:
Without power limiter, without indicator instrument
With power limiter, with indicator instrument

=1
=3

Preferred types
Material no.

Type

R900749982
R900749983

VT5041-2X/1
VT5041-2X/3

Functional description
VT 5041-2X analogue amplifiers are designed as plug-in cards in
Euro-format. As a standard, they are provided with one command
value input each for pressure and swivel angle [1] (power limiter,
optional). The actual pressure value is sensed by a pressure transducer. A position transducer on the pump acquires the actual swivel
angle value. The acquired actual values are processed in an amplifier
[10 and 12] and compared with the injected command values. Minimum value generator [4] ensures that only the controller assigned to
the relevant working point is automatically activated. The output signal of minimum value generator [4] becomes the command value for
the closed control loop of the valve.
The optional power limiter is automatically activated by the feedforward of a suitable command value. The power command value
can be provided internally or externally. If required, it acts directly on
swivel angle controller [3] via a minimum value generator [13].
The actual valve value (position of the valve spool) is acquired by an
inductive position transducer. Oscillator/demodulator circuit [10] processes the signal. Valve spool position controller [5] determines and
processes the system deviation. The output signal of valve controller
[5] forms the command value for self-clocking current output stage
[6], which controls the proportional solenoid of the valve.

The amplifier card is fitted with an error signal output, to which a


voltage of 0 V is applied in the case of an error. At the same time, LED
H1 lights up and the output stage is deactivated.
The following events trigger an error message:
Actual pressure value greater than permissible system pressure
(socket 2 pact > 10 V)
Enable signal missing at connection 26c
Excessive temperature of the output stage
Cable break or range of swivel angle feedback exceeded
Cable break or range of valve spool position feedback exceeded
Cable break proportional solenoid
Cable break pressure transducer (only in conjunction with setting 4 to 20 mA)
In the case of an error, the output stage is deactivated and the valve
spool pushed by a spring to its mechanical end position. The error
can only be acknowledged by a reset of the enable signal.
The pressure-related pump leakage can be compensated for via the
swivel angle control loop using potentiometer [15].
[ ]

RE 30 241/11.02

2/6

= Cross-reference to block circuit diagram on page 3

VT5041

VT 5041

3/6

R1

28a
20a
22a
24a

30a

32a

26c

16c

14c

11

i(u)

R2

12

H2

+
+

8
15 V

+ 15 V

J9

J10

PD

J1...J5

5 +

Explanation re indicator and


adjustment elements (H, R),
Input amplifier
see page 5
Divider
1) For notes on the shielding, see
Min. value generator
Indicator instrument engineering notes for the
Leakage compensation complete system, RE 30030-01-V

+ 4

15

+ 1

14

R9

R7

1k8

1k8

+UB

10

10

H1

26a

12a

10a

14a

26a

6a

4a

8a

12c

24c

2c

2a

30c

28c

16a

18a

Shield 1)

Swivel angle
transducer on
the pump

Shield 1)
(2)

2( )

Measuring
outputs

3
Valve position transducer

act: 10 V bis + 10 V

pact: 0 bis + 10 V

Error signal(^ =Low)

Error signal (^=High)

Proportional
solenoid

Swivel angle control


active =
(^ 24 V)

Power limiter
active =(^ 24 V)

Note:
Connection of the swivel angle transducer is valid for clockwise rotating
pump
("( )" anti-clockwise rotating pump)
Deviations between comm (socket 3) and act (socket 4) can also result
from the setting of R4 (leakage compensation).

R8

R6

PD

+UB

If no external power limit is provided, 18c and 20c must be connected to 0V (22a).

+2

R4

13

11
12
13
14
15

R3

Output stage
Output stage enable
Power supply unit
Cable break detector
Oscillator/demodulator

+UB

J6...J8
10c

8c

4c

6c

20c

6
Differential amplifier
7
Pressure controller
8
Swivel angle controller
9
Minimum value generator
Valve spool position controller 10

0 V ()
15 V

+ 15 V

+ UB

Reference potential

10 to + 10 V

Enable (> 21 V)

comm =

1
2
3
4
5

Reference potential

0 to + 10 V

0 to 5/10 V or
Pact =
0/4 to 20 mA
Reference potential

Pcomm =

Pcomm = (p ): 0 to + 10 V
Reference potential

18c

only with VT 5041-2X/3...

743

Block circuit diagram / pin assignment

241/02.03
RE 30 241/11.02

05

744

Technical data (for applications outside these parameters, please consult us!)
Operating voltage

UB

Operating range:
Upper limit value
Lower limit value

uB(t)max
uB(t)min

Power consumption

PS

Current consumption

Inom

Fuse
Inputs:
Command values (pressure, swivel angle)
Actual value (pressure)
Power selection (p a)comm (only with VT 5041-2X/3...)
Enable
Outputs:
Output stage
Solenoid current / resistance
Drivers for inductive transducers:
Oscillator frequency
Voltage amplitude (USS)
Signal voltages
Actual value (pressure, swivel angle)
Swivel angle control active
Power limiter active (only with VT 5041-2X/3...)
Auxiliary voltages
Error signal
L-active
H-active
Measuring sockets
Pressure command value (pcomm) 1
Actual pressure value (pact) 2
Swivel angle command value (acomml) 3
Actual swivel angle value (aact) 4
Spool position command value (scomm) 5
Actual spool position value (sact) 6

IF
Ui
Ui
Ii
Ui
Ue

Imax
f
Ua
U
U
U
U
Uo
Uo
U
U
U
U
U
U

24 VDC + 40 % 10 %

35 V
21 V
35 VA
0.6 A (Imax = 1.25 A)
1.6 A T
0 to 10 V; Re= 100 k
0 to 5 V or 0 to 10 V; Re= 100 k
0 to 20 mA or 4 to 20 mA; Re= 500
0 to 10 V; Re> 100 k
> 21 V (use relay with contact for currents < 10 mA)

2.5 A; R(20) = 2
ca. 5 kHz
10 V
0 to 10 V
Ub 1 V
Ub 1 V
15 V 3 %; 10 mA
UB 5 V; 10 mA (short-circuit-proof); error at Uo < 1 V
< 1 V; error at UB 5 V; 10 mA
^ 100 %
+ 10 V =
^ 100 %
+ 10 V =
10 V =^ 100 %
+ 10 V ^= 100 %
^ 100 %
10 V =
^
10 V =
100 %

Type of transducer:
for pump
for valve

IW 9 (throttle circuit; 4 mm; 3-wire connection)


DM2 (transformer circuit; 0.6 mm; 4-wire connection)

Type of connection

32-pin male connector, DIN 41 612, form D

Card dimensions

Euro-card 100 x 160 mm, DIN 41 494

Front panel dimensions:


Height
Width circuit board conductor side
Width component side
VT 5041-2X/1...
VT 5041-2X/3...
Permissible operating temperature range
Storage temperature range
Weight
VT 5041-2X/1...
VT 5041-2X/3...

3 HE (128.4 mm)
1 TE
5 TE
9 TE

J
J
m
m

0 to 50 C
20 to + 70 C
0.19 kg
0.21 kg

Note:
For details on Environment simulation tests in the fields of
EMC (electromagnetic compatibility), climate and mechanical stress,
see RE 30 024-U (declaration on environmental compatibility).
RE 30 241/11.02

4/6

VT5041

745

Indicator / adjustment elements: VT 5041-2X/1 and VT 5041-2X/3 from series 25

Leakage
comp.
ON
OFF

Jumper
J9
on
off

Gain of act.
pressure value
Single
Double

J9
R4
H1
H2

J11

R7
J10

R9

Jumper
J10
off
on

R6

R8

R31)

J1 J2
off

R2

on
J6
J3 J4 J5 R1
J7 J8

F1
1,6 A T

on
off

D-component of the pressure controller


Hydraulic fluid volume (in litres)
Jumper position
in the system (actuators plus lines)
J3
J4
J5
5.0
off
off
off
7.5
off
on
off
10.0
on
on
off
15.0
on
off
on
20.0
off
on
on
25.0
on
on
on

Actual pressure value for changeover


Input signal
Jumper position
J6
J7
J8
0 to 10 V
off
off
off
0 to 5 V
off
off
on
0 to 20 mA
on
off
off
4 to 20 mA
on
on
off

P-component of the pressure controller


P-gain
Jumper position
J1
J2 J11
2
on
on
on
2.4
on
off
on
2.7
on
on
off
3
off
on
on
3.4
on
off
off
4
off
off
on
4.8
off
on
off
8
off
off
off

... Factory setting of jumpers

Potentiometers:
R1 Zero point of actual pressure value
R2 Actual pressure value adjustment
(factory setting: right-hand limit stop = max. gain)
R31) Power command value
> is added to an externally provided command value
(factory setting: left-hand limit stop = max. power)
R4 Leakage compensation
(factory setting: left-hand limit stop = min. compensation)
R6 Zero point of valve position transducer
R7 Amplitude of valve position transducer (factory setting)
R8 Zero point of swivel angle transducer
R9 Amplitude of swivel angle transducer (factory setting)

LED lamps:
H1 Error / no enable (red)
H2 Internal voltage supply (green)
1)

For further information and notes, see commissioning instructions


for the SYDFE1-2X closed-loop control system (RE 30 024-B
or latest version of RE 30 022-01-B)!

Only with VT 5041-2X/3

VT 5041

5/6

RE 30 241/11.02

05

746

Unit dimensions

(Dimensions in mm)
VT 5041-2X/3

2
4
6
8

VT
5041

6TE (30,1)

1
3
5
7

2
4
6
8

89

VT
5041

15

1
3
5
7

100

R4
H1
H2
R2

100 50

3HE (128,4)

R4
H1
H2
R2

50 100

VT 5041-2X/1

10TE (50,5)

2
165

186

Potentiometers:
R2 Matching of amplitude pact (pressure transducer)
R4 Leakage compensation
LED lamps:
H1 Error / no enable
H2 Internal supply voltage

Measuring socket:
1
Pressure command value pcomm
2
Actual pressure value pact
3
Swivel angle command value comm
4
Actual swivel angle value act
5
Spool position command value scomm
6
Actual spool position value sact
7 and 8 Reference potential / ground

Supplementary information
Note:

Electrical signals processed by control electronics (e.g. actual value) must not be used for activating safety-relevant
machine functions!
(See also uropean standard Safety requirements for fluid power systems and components hydraulics, EN 982).

For detailed instructions and notes on engineering and commissioning, see:


Engineering aids for fr SYDFEX-2X control systems (RE 30 030-01-V)
Commissioning instructions for SYDFE1-2X control systems (RE 30 022-01-B)

Bosch Rexroth AG
Industrial Hydraulics

Bosch Rexroth Limited

D-97813 Lohr am Main


Zum Eisengieer 1 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail documentation@boschrexroth.de
Internet www.boschrexroth.de

Cromwell Road, St Neots,


Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
eMail: info@boschrexroth.co.uk

RE 30 241/11.02

6/6

The data specified above only serves to describe


the product. No statements concerning a certain
condition or suitability for a certain application
can be derived from our information.
The details stated do not release you from the
responsibility for carrying out your own
assessment and verification. It must be
remembered that our products are subject to a
natural process of wear and ageing.

VT 5041

747
Notes

748
Notes

749
Notes

750
Notes

751
Notes

752
Notes

You might also like