PSSE V32 Part I


T&D Service Solutions
Siemens Power Technologies International

2009 Siemens Energy, Inc. All rights reserved.

PSSE 32 Features

Steady-State & Dynamics Analysis

Steady-State
Steady-State
Power
Power Flow
Flow
Solutions
Solutions

NSOL,
NSOL,FNSL,
FNSL,FDNS,
FDNS,SOLV,
SOLV,MSLV
MSLV

Voltage
Voltage Limit
LimitTransfer
Transfer
Analysis
Analysis

Motor
Motor Starting
Starting

ACCC
ACCC

Fault
Fault Analysis
Analysis

ANSI,
ANSI,BKDY,
BKDY,ASCC,
ASCC,SCMU
SCMU

IEC
IEC Fault
Fault Calculations
Calculations

Graphical
Graphical Model
Model Builder
Builder
Integration
Integration
Small
Small Signal
Signal Analysis
Analysis
NEVA
NEVA Integration
Integration

Reactive
Reactive Power
Power Margins
Margins
Marginal
Marginal Cost
Cost Analysis
Analysis

Enhanced
Enhanced Switched
Switched
PV/QV
PV/QV Analysis
Analysis
Shunt
Shunt Models
Models

New
NewDynamics
Dynamics GUI
GUI

Improved
Improved Contingency
Contingency
Management
Management

Enhanced
Enhanced Event
Event Study
Study
New
Property Sheets
Sheets
New Property

Non-Conforming
Non-Conforming
Load
Load Models
Models

Program Automation Data Management

Large
Large Library
Library of
of
Dynamics
Dynamics Models
Models

Active
Active // Reactive
Reactive
Power
Power Flow
Flow Solutions
Solutions

Stability
Stability
Analysis
Analysis

Contingency
ContingencyAnalysis
Analysis

Optimal Power Flow


Advanced Models
Transmission Reliability

Generic
Generic Wind
Wind Models
Models
Type
Type 1,2,3
1,2,3 && 44
Fully
FullySupported!
Supported!
User-Written
User-Written Models
Models

Python
Python Scripting
Scripting

Model-On-Demand
Model-On-Demand
Data
Data Manager
Manager

Compute
Compute Cluster
Cluster
Processing
Processing Technology
Technology

Integrated
with
Integrated with
PSS/ODMS
PSS/ODMS CIM-based
CIM-based
Data
Data manager
manager

New
Plotting Package
Package
NewPlotting

Contour
Contour Plotting
Plotting

Detailed
Detailed
Excitation
Excitation System
System &&
Governor
GovernorModels
Models

Corrective
Corrective Actions
Actions

HVDC
HVDC&& FACTS
FACTS
Models
Models

Enhanced
Enhanced Plotting
Plotting
Scenario
Scenario Manager
Manager
Integrated
Integrated Command
Command
Line
Line

Probalistic
Probalistic Reliability
Reliability
(from
(fromTPLAN)
TPLAN)
Substation
Substation Reliability
Reliability
Assessment
Assessment
(from
(from TPLAN)
TPLAN)

Overhauled
Overhauled
Documentation
Documentation

1.5
LE-Volt [ pu]
AE

Bus/Breaker
Bus/Breaker && Zero
Zero
Impedance
Impedance Line
Line loop
loop
Support
Support

DIF-Volt[ pu]
110KVT2. R
BETR.SIE R

0.0
-1
75
THETA [ Deg]
GT5MVA

1000
P
[ MW]
SL5-2

THETA [ Deg]0
DT2.5MVA

Q
[ pu]
GT5MVA

P
[ pu]
GT5MVA

-75
1

Enhanced
Enhanced Short-Circuit
Short-Circuit
Analysis
Analysis

-1

-1
1

MMECH [ pu]
GT5MVA

-1000

MEL [ pu]
GT5MVA

SVC_DEMO

October 10

15.9.1999

21:08

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International
1

+ 0.7 pu

0.0

SIEMENS AG, EV NP

Page 2

Powerful
Powerful Graphics
Graphics &&
MS
MS Spreadsheets
Spreadsheets

PSS/E
PSS/E Engine
Engine "callable"
"callable"
by
by 3rd-party
3rd-party Apps
Apps

1.5

3.0

LE-Volt [ pu]
BETR.SIE R

-1
1

4.5

VOLTAGE AND
ACTIVE PO
R

6.0

SEC

- 0.7(LFC)
pu
LOAD FLOW CONTROLLER
0
0
SVC ON NODE AE
WITH RANGE +/- 400.000, FREQUENCY CONTROOLED
PAGE
.
1
-1
-1
Produced with NETOMAC (R) NETOMAC is a registered trade-mark of Siemens AG
5
IA_HV [ pu]
GT5MVA
0

-5
0.0

SIEMENS AG, EV NP
DOKUNEU
15.9.1999

21:01

Generatorgren
Bild 1 von 1

0.4
0.8
TESTRECHNUNG (DOKU)
bergang Momentanwertteil - Stabilittsteil
Erstellt mit NETOMAC fr Windows
SIEMENS AG EV_NP2-dn0040/Ru

1.2

1.6

SEC

1
Produced with NETOMAC(R) NETOMAC is a registered trade-mark of Siemens AG

Power Flow Interface

2009 Siemens
Energy, Inc. All rights reserved.
2009 Siemens Energy, Inc. All rights reserved
Page 3

October 10

Siemens Power Technologies International

Views in the Power Flow Interface


Menu Bar
Toolbars
Diagram
View
Tree
View
Spreadsheet
View

Report/
Progress
Window

Status
Bar

Multiple
Tabs

Page 4

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

To Create a New Case


Use menu bar File>New or toolbar button
Choose New Network Case
Enter Base MVA, frequency, rating options

Page 5

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Network Data Editing (V30, V31 & V32)

This row of data being edited. In V30


or V31, must move cursor to another
row or click on pencil to confirm data
change. In V32, press <enter> after
data entry in cell is enough.
Page 6

October 10

One tab for each


data category
2009 Siemens Energy, Inc. All rights reserved
Siemens Power Technologies International

Revised Spreadsheet/Tree View Organization


(V32.0)
Tabs and folders in Spreadsheet & Tree View re-ordered and synchronized.
Tab labels fully exposed.
Excel-like tools and Context-menu allow easy selection of tabs.

Page 7

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Configurable Spreadsheets (V32.0)


Change precision for any column
Change font / style / color for any column

Page 8

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Regional Settings (V32.0)


Preference for displaying numbers in cells according to Regional and Language
Options in Control Panel.

Page 9

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Configuration Resets (V31)


Version 30.3 introduced the ability to
memorize spreadsheet customizations.
Added two new functions
to reset the spreadsheets to
default configurations.
Reset the active spreadsheet
Reset all spreadsheets
Added new function to reset most
application dialogs to their default
configurations.

Page 10

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

After Editing, Save the Data

File > SAVE or Show > Case Data - Saves a power flow model (working case) in
binary or raw data format

Page 11

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Toolbars
Tools > Customize Toolbars

Page 12

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Automation Toolbar

Command line input


Start / stop recording (PYTHON, IDEV file)
Run automation file (PYTHON, IDEV, IPLAN file)
Re-run automation file (V32)
Edit last recorded automation file
Edit last run automation file

Page 13

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Analysis Toolbar

Solution settings
Solve
PV analysis
PV analysis using previous results
QV analysis
QV analysis using previous results
AC contingency solution (ACCC)
Multi-level AC contingency solution

Page 14

October 10

AC corrective action
Reliability assessment
Substation reliability assessment
Network connectivity check (TREE)
Solve for switching
Inertial power flow
N-1-1 analysis

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

To Create a New Diagram


Use menu bar File>Open or toolbar button
Choose New Diagram

Page 15

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Contour Plotting (V30.3)

Page 16

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Bus Location File


File>Open (*.loc)
Controlled through Preferences
dialog
Can also update existing diagram: Diagram>Update bus locations
Bus locations can be specified in either CARTESIAN or GEOPHYSICAL
coordinates

Page 17

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Diagram View Results Toolbar

Toggle labels
Diagram annotation
Power flow solution results
Power flow impedance data
Also activated from Menu Bar
Graphical case comparison
(Diagram>Results)
ASCC fault analysis
IEC analysis
Reliability analysis
Dynamic simulation models
Flow animation
Current loading bar chart
Multi-section line reporting
Lock diagram (but not from deleting or moving equipment)

Page 18

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Current Loading Bar Chart


I: % rating based on current
S: % rating based on MVA

Properties can be changed in:


Diagram Annotation
Diagram Properties
Diagram Range Checking

Page 19

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Editing Network Data From Diagram (V32.0)

Select item in diagram and right click to bring up property sheet

Edit > Preference

Page 20

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

GRPG-Style Report Node (V32.0)


Present results of a Python function on a diagram
Arguments may be passed Python functions
Sample file usegrpg.py has some GRPG functions

Page 21

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Diagram Templates (V32.0)


Common network equipment configurations can be created and reused.

Page 22

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Saving the Slider Diagram


In Diagram view, under File > Save, or File > Save as
Two formats:
Slider binary file (*.sld)
Slider XML file (*.sldxml, text file)
Power flow case not saved simultaneously when slider diagram is saved, and
vice versa.

Page 23

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Navigating Between Views

Mouse click on item to go between different views:

Tree View
Double click to
edit data

Spreadsheet View
Select
diagram
window

Right
click to
locate

Double
click to
edit data

Progress
Window
Double
click for
GOUT

Report
Window
Double
click for
GOUT

Diagram View
Page 24

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Configuration Resets (V31)

Version 30.3 introduced the ability to


memorize spreadsheet customizations.

Added two new functions


to reset the spreadsheets to
default configurations.
Reset the active spreadsheet
Reset all spreadsheets

Added new function to reset most


application dialogs to their default
configurations.

Page 25

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

More Program Settings in V31


(Misc > OPTN)
% branch loadings reported
according to MVA or current
Print winding buses of 3winding transformers in
POUT, LOUT, LAMP
Print outaged branches in
POUT, LOUT and LAMP

Page 26

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Newton Solution Convergence Parameters (V30.3)

Two new solution parameters in Version 30.3:


Controlled bus Q mismatch convergence tolerance
(VCTOLQ = 0.1 MW/Mvar)
Controlled bus voltage error convergence tolerance
(VCTOLV = 0.00001 pu)

Ensure voltage at controlled bus is being controlled if at least one of its


controlling devices is not at var limit.

Compatibility with convergence test in previous releases:


Version 28 or earlier, set VCTOLQ = 1000, VCTOLV = TOLN/SBASE
Version 29.0 through 29.5.1, set VCTOLQ=TOLN, VCTOLV =10
Version 30.0 through 30.2.2, set VCTOLQ=TOLN, VCTOLV=0.0001

Page 27

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Allows Multiple Voltage Controlling Devices (V30.1)

Multiple set-point mode voltage controlling devices are allowed on the same
bus or on buses connected by zero impedance lines, such as
Generators
Switched shunts
Shunt elements at the sending end of FACTS devices
VSC dc line converters
An RMPCT data item is now associated with switched shunts and FACTS
devices.

Page 28

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Switched Shunt Adjustment (V31)


Switched shunts which control voltage to a band can oscillate due to:
Multiple devices electrically close to each other
Large admittance blocks
Narrow voltage bands
New solution parameter SWVBND specifies the percentage (population) of
such switched shunts whose controlled voltage is outside of the desired
voltage band which can be adjusted on any single adjustment cycle.

Page 29

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Switched Shunt Adjustments (V32.0)


Previous adjustment method:
Pre-defined switching sequence based on input order
Reactor & capacitor components cannot be on simultaneously
New features:
Status attribute
Both reactors and capacitors can be on at the same time
Optional adjustment method to find a combination of reactors and/or
capacitors with the next larger/smaller total admittance.

Page 30

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Multiple Fixed Shunts at a Bus (V31)

Similar in data structure to loads and machines


Identified by bus and 2-character ID
Can be switched in/out
Inherits area, zone and owner attributes of bus
Negative sequence same as positive sequence
Can enter separate zero sequence admittance

Page 31

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

New Transformer Code (V31)

Page 32

When CW = 3, transformer turn ratios (WINDV) and limits (RMAX and


RMIN) for voltage or MVAR controlling transformer windings are
specified in pu of nominal winding voltage (NOMV)

(When CW = 1, items are specified in pu of winding bus base voltage)

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

FACTS Devices (V31)

Shunt element may control voltage at remote bus

A switched shunt can control reactive power setting of the shunt element of a
FACTS device

Maximum number of FACTS devices is increased:


From 20 to 50 at 4,000 through 11,000 buses
From 40 to 100 at 12,000 through 49,000 buses
From 99 to 250 at 50,000 buses and above

Page 33

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

FACTS Devices & DC Lines Identifiers (V31)

Identify FACTS devices, two-terminal dc lines, and multi-terminal dc lines by


a 12 character device name

Same approach as VSC dc lines

When old Saved Case File is read, device names are set to old device
number, left justified

Old Response Files, Python programs, and IPLAN programs referencing


device numbers will continue to work

Page 34

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Wind Machines (V31)

Wind machine explicitly identified in power flow data


Control Mode:
0 = non-wind machine
1 = specified var limits (same as non-wind machines)
2 = use var limits from MW output and specified PF
3 = fix var output determined from MW output and specified PF

Page 35

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Non-Conforming Loads (V32.0)

Each load is characterized as either conforming (i.e., scalable) or nonconforming (i.e., fixed)

Only conforming subsystem loads:


Are modified during load scaling
using SCAL API
Participate in transfer increment
in P-V analysis

Page 36

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Zero-Impedance-Line Loops (V32.0)


Branches for breakers and switches can be modeled as zero impedance lines.
Restriction which prohibited zero impedance line-connected loops removed.

Page 37

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Transformer Phase Shift Angle Adjustment (V32.1)

For some European transformers, a change in phase shift angle results in a


change of turns ratio.

Transformer control mode (5) to select asymmetric phase shift angle


adjustment to control active power flow.

For regular (symmetrical) phase shifter, control mode is 3, as before, and


winding connection angle is not used.

Page 38

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Report of Load Reduction in Power Flow Solution


(V32.0)
Constant MVA loads which have been reduced due to bus voltages below
PQBRAK.
Constant current loads which have been reduced due to bus voltages below
0.5 pu.

Page 39

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Expanded AREA and ZONE Reporting (V32.0)

AREA report tabulates 3 categories of load:


Area load at area buses, Area load at non-area buses, Non-area load at
area buses
AREA report tabulates 2 categories of net interchange:
Tie flows, Tie flows plus loads
Similar options for ZONE reporting

Page 40

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Area, Owner and Zone Numbering (V32.0)

4 digit zone number at any program size level

Allow area, owner and zone numbers of 1 through 9,999 at all program size
levels

Limits remain on the number of area, owners and zones that may be
represented in a power flow case
These continue to be dependent on the dimensional capacity of PSSE
which is running

Page 41

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Subsystem Loads in RAWD Output (V32.0)

Option in RAWD indicating which loads are to be included in output:


All loads at subsystem
buses
Subsystem loads at all
buses
All loads at subsystem
buses and subsystem
loads at non-subsystem
buses

Page 42

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Contingency Analysis

2009 Siemens
Energy, Inc. All rights reserved.
2009 Siemens Energy, Inc. All rights reserved
Page 43

October 10

Siemens Power Technologies International

Contingency Analysis Setup


Prepare base case (N-0)
Prepare and input data files:
Study area (Subsystem Description file *.sub)
Equipment to be monitored (Monitored Element File *.mon)
Contingencies to be tested (Contingency description File *.con)
Other auxiliary data files
Read basic input data files (DFAX)
Perform contingency analysis
DC analysis
AC analysis
Multi-level AC analysis
Review results in tables or diagrams

Page 44

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Build Distribution Factor Data File (DFAX)


(Power Flow > Linear Network >
Build Distribution Factor Data File)
Pre-processor for contingency
and transfer limit calculations:
Reads data from:
SUBsystem description file
MONitored element file
CONtingency description File
Calculates line outage distribution factors for
linear analysis
Stores information in binary output file (DFX)

Page 45

October 10

SUB

MON

CON

DFAX

DFX

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Subsystem Description File


SYSTEM MONITOR6
AREAS 6 10

------->

Areas 6 to 10 inclusive

END
SYSTEM WEST
BUSES 3001 3008

------->

Buses 3001 through 3008 inclusive.

END
SUBSYSTEM CONT2

------->

Subsystem means the same as System

------->

JOIN defines elements between 230 & 500 kV


AND within Area 2

JOIN
AREA 2
KVRANGE 230 500

END
END
END
Specify generator/load buses participating in generator/load shift for transfer limit analysis:
PARTICIPATE
BUS 123 0.4
BUS 456 0.6
END

Page 46

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Monitored Element File


MONITOR BRANCHES
3004 152
3006 153
3008 154
201 151
202 152
203 154
205 154
END
MONITOR INTERFACE WEST RATING 200 MW
3004 152
3006 153
3008 154
END
MONITOR INTERFACE EAST RATING 350 MW
MONITOR TIES FROM AREA 1 TO AREA 2
END
END

Page 47

October 10

Interfaces can be input as


as individual branches or
as a group. E.g., Interface
East is all tie lines from
AREA 1 to AREA 2.

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Contingency Description File


CONTINGENCY TRIP1NUCLEAR
REMOVE UNIT 1 FROM BUS 101 dispatch
bus 3001 .2
bus 3008 .1
bus 201 .2
bus 206 .2
bus 102 .3
end
END
CONTINGENCY EASTLINE1
TRIP LINE FROM BUS 3004 TO BUS 152
END
CONTINGENCY EASTLINE2
TRIP LINE FROM BUS 3006 TO BUS 153
END
CONTINGENCY DOUBLE1
TRIP LINE FROM BUS 153 TO BUS 154 CKT 1
TRIP LINE FROM BUS 153 TO BUS 154 CKT 2
END
END

Page 48

October 10

Number of contingency
elements per event
increased from 16 to 32
in V32.

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Shunt Contingencies in V32


New command to trip in-service switched shunt

REMOVE SWSHUNT FROM BUS 1234


ALTER /SET /INCREASE /DECREASE ... SHUNT commands recognize the MVAR
keyword, in addition to MW and PERCENT

SET BUS 5678 SHUNT TO -200 MVAR


ADD & REMOVE commands allow status change of an individual load or fixed shunt

ADD SHUNT 2 TO BUS 7890

Page 49

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

More Contingency File Options (V32.0)

Command to change current or power demand or scheduled compounded dc voltage


of two-terminal dc lines, e.g.

SET TWOTERMDC XYZ-DC TO 500 MW

Command to generate single machine contingencies (At buses with multiple machines,
the one with largest PGEN selected), e.g.

SINGLE MACHINE IN SUBSYSTEM ABC

Command to disconnect in-service buses, e.g.

SINGLE BUS IN KV 345

Number of contingency elements per event increased from 16 to 32.

Page 50

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Breakers & Switches in Configuration Files (V32.0)

Breakers and switches introduced as non-transformer branches with @ or * in branch


ID.

Use keyword breakers to include breaker and switch branches in MON file, e.g.

Monitor breakers in area 1

Use keyword breaker to include breaker and switch branches in CON file, e.g.

Single breaker in zone 2


Double breaker from bus 5000

Page 51

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Configuration File Builder (V30.3)


Build contingency analysis files by
selecting options
SUB Choose bus subsystem by picking
name from existing subsystem definitions
or by using bus subsystem selector and
giving new name
MON Monitor bus voltages and/or
branch flows within subsystem
CON Define contingency groups within
subsystem

Page 52

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Defining Configuration File Text Editor


Edit> Preferences

Edit file

Define text
editor
Page 53

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Bus Renumbering for Contingency


Analysis Input Data Files (V32.0)
Bus renumbering (RNFI) can now be applied to:
Subsystem description data file
Monitored description data file
Contingency description data file
Tripping data file
Load throwover data file

Page 54

October 10

2009 Siemens Energy, Inc. All rights reserved


Siemens Power Technologies International

Break time!

Siemens
AG 2009. All rights reserved.
2009 Siemens Energy, Inc. All rights reserved
Page 55

October 10

Siemens Power Technologies International