You are on page 1of 16

API Std 650 Storage Tank

KDDB

Data Sheet

PAGE

* For boxes marked with *, if blank, Mfr. Shall determine and submit as per Appendix L. For all lines, see Appendix L for line-by-line instructions.
GENERAL Special Documentation Package Requirements:
SI

Measurement Units to be used in API Std 650:


1.

US Customary

Manufacturer*

Contract No.*

Address*
Mfg. Serial No.*
2.

Year Built*

Edition & Addendum to API 650* 12th Edition-Latest

Purchaser

Contract No.

Address
Tank Designation
3.

Owner/Operator

4.

Size Limitations*

Location Kuwait
Tank Diameter*

Capacity: Maximum*
5.

Net Working*

1193 m

Crude Oil

Max. S.G.:

1.02

Blanketing Gas

15.56

Suppl. Spec.
Yes

No

Yes

PSIA at Max. Operating Temp.


No

Suppl. Spec.

Suppl. Spec.

DESIGN AND TESTING

Purchaser to Review Design Prior to Ordering Material?

6.

Applicable API Standard 650 Appendices:*

7.

Max. Design. Temp.


Design Pressure

13

H2S Service?

Other Special Service Conditions?

6.89 kPa

Floatation Considerations?
Seismic Design?

Yes

Yes

Check Buckling in Corroded Cond.?


1-Ft Mthd?*

Plate Stacking Criteria*

120 m /Hr

Yes

No

Maximum Emptying Rate

S1

S0

Site-Specific Procedures: MCE

Sp = 0.075
No

162 km/Hr
Use Top Wind Girder as Walkway?

Intermediate Wind Girder Style*

Yes

8.4 m

Dimensions*
No

Seismic Use Group

Ss

Yes

Wind Velocity for non-U.S. sites, 50-yr. wind speed (3-sec. Gust)*

Yes

Vertical Ground Motion Accelerator AV:

Other (Non-ASCE) Methods

Detail - 'I'

Design Liquid Level*

No

Mapped Seismic Parameters?


;

No

Applied Supplemental Load Spec.

Freeboard Required for SUG I Design Roof Tie Rods @ Outer Ring?*

Intermediate Wind Girders?*

Yes

Alternate Seismic Criteria

Vertical Seismic Design?

Basis of Lateral Acceleration (Select one):

Top Wind Girder Style*

Maximum Fill Rate

Appendix E

No

Flot. Suppl. Spec:*

No

Yes

Design Metal Temp.*

No

Design Required?

External Pressure -3.44 kPa

Yes

MBE Site Class

10. Shell Design:

at

Vapor Pressure

% Aromatic

9.

Shell Height*

Products Stored:
Liquid

8.

15m

Criteria*

Yes

Dimensions*

No
;

Variable-Des-Pt Mthd?* Yes

Centerline-Stacked? Yes

No

No

Alternate

Flush-Stacked? Yes

No

Elastic Anal. Mthd?* Yes


Inside

No

Outside

Plate Widths (Shell course heights) and Thicknesses * Numbers below Indicate Course Number.
1. 2400 x 8

2. 2000 x 8

3. 2000 x 8

4. 2000 x 8

6.

7.

8.

9.

11.

12.

13.

14.

Joint Efficiency*
Approvals:

% Shell-to-Bottom Weld Type*


Revisions:

5.
10.
15.

Shell-to-Bottom Weld Insp. Mthd*


Title:
By:
Drawing No.:

Ck'd:
Sheet

OF

12th Edition-Latest

Kuwait
8.4m

Maximum Emptying Rate 120 m3/Hr

Seismic Use Group

Site-Specific Procedures: MCE

No

Alternate

Date:
Sheet

of

API Std 650 Storage Tank

AMETANK

Data Sheet

PAGE

* If box is blank, Manufacturer shall determine and submit as per Appendix L.


11. Open-Top and Fixed Roofs: (See Sheet 6 for Floating Roofs)
Fixed Roof Type*
Cone Slope*

Cone
1:6

Open Top?*

Roof Support Columns*:

Yes

No

Pipe

Dome or Umbrella Radius*

Or Structural Shape

Weld Joints* Lap


(Lap, Butt, Other)

Seal Weld Underside of:


Gas-tight?

Lap Joints? Yes

Yes

Thickness*

No

7 mm

No

Seal Weld Underside of Wind Girder Joints?

App. Suppl. Load Spec.*

13.

Bottom: Thickness*

10

Provide Drip Ring?

Yes

No

Annular Ring?

Yes

No

Yes

No

Style* Cone - Up

Slope* 1 : 35

Inward

Weld Joint Type*

Outward

Lap

Alternate Spec.
Annular Ring: Minimum Radial Width*

750 (min)

Thickness*

Foundation: Furnished by*

10 mm

Type* Ring Wall


Per Spec.*

Anchors: Size* VTC

Foundation Design Loads: Base Shear Force: Wind*

Seismic*

Ring Forces: Weight of Shell + Roof New*


Partial Vacuum*

Qty.*

Overturning Moment: Wind* VTC

Corroded*
Wind*

Seismic*

Roof Live Load* 1.2 kPa

Internal Pressure*

Seismic*

Bottom Forces: Floor Wt. New*

Corroded*

Partial Vacuum*

Other Foundation Loads*

Responsibility for Heating Water, if Required:


Hydro-Test Fill Height*

Weld Rafters to Roof Plates?

Radial Projection of Horizontal Component of Top Angle*

Detai 'I' of Annex -F - Fig F-2

Soil Allow: Bearing Pressure*

14.

Column Lateral Load

Emergency Venting Devices*

For Non-Frangible Roofs: Seal Weld Roof Plates to Top Angle on the Inside?

12.

No

Joint Efficiency*
In. Snow Load*

Normal Venting Devices*

Roof-to-Shell Detail*

Yes

Product Wt.*

Purchaser

8.4 m

Water Wt.*

Internal Pressure*
Min. Projection of Fdn. Above Grade:

Manufacturer

Settlement Measurements Required?

Yes

No

Extended Duration of Hydro-Test:

Predicted Settlement Profile is Attached


Responsibility for Setting Water Quality:

Purchaser

Manufacturer

Supplemental Test Water Quality Spec.

Test Water Source & Disposal Tie-In Locations

Hydro-Test Appendix J Tank?

Post-Pressure-Test Activities Required of the Manufacturer:

Broom Clean

Potable Water Rinse

Dry Interior

Other
15.

Inspection by

in Shop;

Supplemental NDE Responsibility

Supplemental NDE Spec.


(Purch., Mfg., Other)

Positive Material Identification?

Yes

No

PMI Requirements:

Max. Plate Thickness for Shearing


Must Welds not exceeding 6 mm (1/4 in.) Be Multi-Pass?
Leak Test Mthd: Roof*
Bottom*

As per API 650

Yes

Must Welds greater than 6 mm (1/4 in.) Be Multi-Pass?

No

Shell* As per API 650

Shell Noz./Manhole Reinf. Plt*

Floating Roof Components*

Modify or Waive API Dimensional Tolerances (see 7.5)?

No

Yes

Specify:

Specify Additional Tolerances, if any, and Circumferential and Vertical Measurement Locations:
Measure and Record at a Minimum of
- Allowable Plumbness:
1

the Following Shell Heights: (select one box):

/3 H, 2/3 H and H

Locations or Every

/3 H, 2/3 H and H

m (ft) around the Tank, at

Top of Each Shell Course

- Allowable Roundness:**
Measure Radius and Record at a Minimum of
around the Tank, at the Following Shell Heights (select one box):
Top of Tank, H

Yes

Other:
Locations or Every

Top of Each Shell Course

Other:

**See Data Sheet Instructions for the Maximum Allowable Additional Radial Tolerance.
Approvals:

Revisions:

Title:
By:
Drawing No.:

Ck'd:
Sheet

OF

Lap

Weld Rafters to Roof Plates?

Yes

No

Outward
Lap

Ring Wall
Qty.* VTC
Seismic* VTC
Internal Pressure* 6.89 kPa

Internal Pressure*
Min. Projection of Fdn. Above Grade:

Extended Duration of Hydro-Test:

Supplemental Test Water Quality Spec.


Yes

No

in Field

Yes

No

m (ft) around the Tank, at


m (ft)

Date:
Sheet

of

API Std 650 Storage Tank

AMETANK
16.

Data Sheet

PAGE

Coatings:
Internal Coatings by:

Per Spec.* As Per Spec

External Coating by:

Per Spec.* As Per Spec

Under-Bottom Coating by:

Per Spec.* As per Spec

(Not Req'd., Others, Tank Mfg.)


(Not Req'd., Others, Tank Mfg.)
(Not Req'd., Others, Tank Mfg.)
17.

Cathodic Protection System?

Yes

No

Per Spec.*

18.

Leak Detection System?

Yes

No

Per Spec.*

19.

Release Prevention Barrier?

Yes

No

Per Spec.*

20.

Tank Measurement System: Required?

Yes

No

By:*
21.

Weight of Tank: Full of Water*

22.

References:* API Std 650, Appendix L

23.

Remarks:*

Remote Capability Required?

Yes

No

Per Spec.*
Empty*

Shipping*

Brace/Lift Spec.*

1. Nozzle Elevation and Orientation to be confirmed after site visit on contract award
2. the T

Approvals:

Revisions:

Title:
By:
Drawing No.:

Ck'd:
Sheet

OF

Date:
Sheet

of

API Std 650 Storage Tank

AMETANK

Data Sheet

PAGE

* If box is blank, Manufacturer shall determine and submit as per Appendix L.


Table 1 MATERIALS OF CONSTRUCTION
Component

Material*/Thickness*

Shell, Course _1__ to _4__

C.A.

A 283 Gr C - 8 mm

1.6

Component

Material*

Reinforcing Pads

A 283 Gr C

Shell, Course ___ to ___

Manhole/Nozzle Necks

A 283 Gr C / A 106 Gr B

Shell, Course ___ to ___

Manhole/Nozzle Flanges

A 283 Gr C / A 105

Shell, Course ___ to ___

Flange Covers

A 283 Gr C

Shell, Course ___ to ___

Anchor Attachments

A 283 Gr C

Roof

A 283 Gr C

1.6

Submerged Piping

A 106 Gr B

Bottom

A 283 Gr C

3.2

Wetted Structurals

A 36 / S275 JR

Annular Ring

A 283 Gr C

3.2

Non-wetted Structurals

A 36 / S275 JR

+ Check here if C.A. is to apply to each exposed sur


Table 2 BOLTS and ANCHORS
Component

Head Type*

Bolt or Anchor Material*

Nut Material*

Thread Series*

Flange Bolting

HEX

A 193 Gr B7

A 194 Gr 2H

UN

Structural Bolting

HEX

A 327

A563

UN

Anchor Bolts

HEX

A 307 / BS4190

A 563

UN
UN

++ Total C.A., on the nominal diameter.


Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Mark

Service

Size, NPS,
or Dia. (in.)

Neck Sch
or Wall
Thick.

Reinf. Plate
Dimensions

Full Pen.
On Open.
(Y/N)

Flange
Type

Flange Class
or Thick.

Proj. to FF or CL
or from Datum
Lines

Remaks
Gasket Thick.
and Dimen.

Shell Nozzles
N1

Inlet

8"

WNRF

150#

Note-4

N2

Outlet

8"

WNRF

150#

Note -5

N3

Level

3"

WNRF

150#

N4

Level

3"

WNRF

150#

N5

Level

3"

WNRF

150#

N6

Level

3"

WNRF

150#

N7

Spare

4"

WNRF

150#

N8

Drain

3"

WNRF

150#

N9

4"

WNRF

150#

N10

Foam
Sample
Connection.

1"

WNRF

150#

N11

Recirculatio
n Line

3"

WNRF

150#

N12

Heating Coil

3"

WNRF

150#

N13

Heating Coil

3"

WNRF

150#

N14

Spare

3"

WNRF

150#

W/ Blind

N15

Spare

3"

WNRF

150#

W/ Blind

N16

Spare

3"

WNRF

150#

W/ Blind

M1

Clean Out

24"

Approvals:

W/ Blind

VTC

As per API 650


Revisions:

W/ Cover+D
Title:

By:
Drawing No.:

Ckd:
Sheet

OF

MATERIALS OF CONSTRUCTION
Material*

C.A.

A 283 Gr C

1.6

A 283 Gr C / A 106 Gr B

1.6

A 283 Gr C / A 105
A 283 Gr C
A 283 Gr C

1.6

A 106 Gr B

1.6

A 36 / S275 JR

1.6

A 36 / S275 JR

1.6

+ Check here if C.A. is to apply to each exposed surface

e 2 BOLTS and ANCHORS


Thread Series*

C.A.

UN

++

UN

++

UN

++

UN

OLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Remaks

Note-4
Note -5

W/ Blind

VTC

W/ Blind
W/ Blind
W/ Blind
W/ Cover+Davit

Date:
Sheet

of

API Std 650 Storage Tank

AMETANK

Data Sheet

PAGE

* If box is blank, Manufacturer shall determine and submit as per Appendix L.


Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Mark

Service

Size, NPS,
or Dia. (in.)

Neck Sch
or Wall
Thick.

Reinf. Plate
Dimensions

Full Pen.
On Open.
(Y/N)

Flange
Type

Flange Class
or Thick.

2"

WNRF

150#

Remaks

Proj. to FF or CL
or from Datum
Lines

Gasket Thick.
and Dimen.

ROOF Nozzles
N17

4"

WNRF

150#

N19

VENT
BLANKET
GAAS
Emergenc
y Vent

24"

WNRF

150#

N20

PVSV

6"

WNRF

150#

M2

Manhole

24"

N21

MTG LVL

2"

WNRF

150#

N22

Spare

2"

WNRF

150#

W/ Blind

N23

Spare

2"

WNRF

150#

W/ Blind

Clean Out

24"

N18

Approvals:

GAS
Note -5

W/ Emergency

As per API 650

W / Cover + D

As per API 650


Revisions:

W/ Cover+D
Title:
By:
Drawing No.:

Ckd:
Sheet

OF

OLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)

Remaks

GAS
Note -5
W/ Emergency Vent

W / Cover + Davit

W/ Blind
W/ Blind

W/ Cover+Davit
Date:
Sheet

of

API Std 650 Storage Tank

AMETANK

Data Sheet

PAGE

* If box is blank, Manufacturer shall determine and submit as per Appendix L.


OTHER TANK APPURTENANCES
24.

Platform, Stairway, and Railing: Galvanizing Req'd?*

Yes

Stairway Style* Spiral

No

Walk Surf. Type*

(Straight or Helical)
Stair and Walkway Clear Width*

1000 mm

National Safety Standards*

Architectural/Structural Specification*
Gauger's Platform Req'd?
25.

Yes

Jacket Required?*

Yes

No

Qty. Req'd*

No

Per Spec.*

Other Heaters/Coolers Required?*

Yes

No

Supplemental Jacket, Heater, or Cooler Specifications*


26.

Mixer/Agitator:

Quantity

27.

Insulation: Required?

Yes

Size*
No

Per Spec.*

Thickness*

Material*

Per Specs*

Responsibility for Insulation and Installation


(Purchaser, Manufacturer, Others)

28.

Structural Attachments: Lift Lugs?*


Shell Anchorage?*

29.

Yes

Yes
No

Desc.*

Type*

Various Other Items: Welded Flush-Type:


Miscellany #1

No

Scaffold Cable Support?


Shell Connection

Heating Coil

Cleanout Fitting

Waive Application of Appendix P?

Miscellany #2

Miscellany #3

Miscellany #4

Miscellany #5

Miscellany #6
Table 4 OTHER TANK APPURTENANCES*

Mark

Approvals:

Quantity

Service or
Description

Revisions:

Size

Orientation

Height from Datum

Material

Title:
By:
Drawing No.:

Ck'd:
Sheet

OF

Greating

(Purchaser, Manufacturer, Others)

Yes

No

Yes

No

THER TANK APPURTENANCES*


Material

Remarks

Date:
Sheet

of

API Std 650 Storage Tank

AMETANK

Data Sheet

PAGE

* If box is blank, Manufacturer shall determine and submit as per Appendix L.


Tank Plan and Sketches:

Notes:

Approvals:

Revisions:

Title:
By:
Drawing No.:

Ck'd:
Sheet

OF

Date:
Sheet

of

You might also like