Price List 2014-2015

n Floor-Standing Boilers
n Wall-Mount Boilers
n Domestic Hot Water Tanks
n System Technology
n Solar Systems
n Commercial Boilers
n Biomass Boilers

Effective 1-Sep-14; Revised 19-Feb-15

USA

Contents

Vitorond 100

Sectional
cast iron boilers

91 to 245 MBH

Oil-Fired Heating Boilers


91 to 245 MBH

Vitodens 100-W

Wall-mount boilers

37 to

Gas-Fired Condensing Boilers


12 to 530 MBH

17

Vitodens 200-W

45

Vitodens 222-F

Floor-standing
boilers

53

Vitocrossal 200

Steel/stainless
steel boilers

118 MBH


12 to 125 MBH

Vitorcrossal
200

Indirect-Fired Domestic
Hot Water Storage Tanks

Heating System Controls

67
Vitotronic 200-H
74
BMS Gateways
75
Low-Loss Headers
Transport
79
84
86
88
90
93
100

Vitosol
Vitosol 100-F
Vitosol 200-F
Vitosol 200-T, SPE
Vitosol 200-T, SP2A
System Technology
ESOP NA 4.0

Solar Combi-Packages
plate collectors

Solar Collectors

Vacuum tube
collectors

System Technology

101

Vitorond 200

Sectional
cast iron boilers

103

Vitorond 200

105

Vitocrossal 300

Steel/Stainless Steel
boilers

107

KOB Wood Fired Systems

Biomass boilers

Simulation Software


111

Terms and Conditions of Sale, Delivery and Payment

113

Venting Categories for Gas-Fired Boilers

114

Viessmann Warranties

115

Approval and Listing Overview

121

Viessmann North America Contact Information

This trademark is registered with the U.S. Patent and Trademark Office.

638 to 3361 MBH

512 to 1843 MBH


1330 to 4268 MBH

Vitosol

Oil-/Gas-Fired Heating Boilers


490 to 4387 MBH
Gas-Fired Condensing Boilers
638 to 3361 MBH

Vitorond
200

490 to 1096 MBH


1255 to 4387 MBH

Pyrot
Pyrotec

Vitotronic

Hydronic Heating Accessories

Biomass Boiler
with Automatic Fuel Feed System
512 to 4268 MBH

Vitocrossal
300

DHW Pump Module and


Electronic Anode

119 USG
119 USG

Appendix

KOB

42 to
42 to

Gas-Fired Condensing Boilers


133 to 2245 MBH

Vitocell

133 to 2245 MBH


Vitocell 100
Vitocell 300

Vitodens

12 to 530 MBH


59
61

Vitorond
100

PAGE

VITOROND 100

Vitorond
100

Hot water heating boiler 91 to 245 MBH / 27 to 72 kW

Vitorond 100 with Beckett Burner and


HydroLevel Control

Vitorond 100 with Beckett Burner


and Vitotronic 100 KW10B Control

Vitorond 100

Eutectoplex heat exchanger for high operational reliability and a


long service life.

VR1 Series

Triple-pass heat exchanger design provides reduced emissions,


efficient fuel utilization and low heating costs.

Oil-Fired Boiler
for hydronic heating systems
of cast iron sectional construction
Heating input: 91 to 245 MBH

27 to 72 kW

Economical and environmentally friendly operation

This trademark is registered with the U.S. Patent and Trademark Office.

Problem-free cleaning access facilitated by a hinged (left or


right), swing-open combustion chamber door providing easy
access to all three heat exchanger passes from boiler front.

VITOROND 100

System Type

Control Option

HydroLevel

thermal reset boiler control


with wall mounting kit
with integrated low-water cut-off function

OTS

1 heating circuit
without mixing valve

Vitotronic 100, KW10B

OTS

for high temperature heating systems

1 heating circuit
without mixing valve
1 DHW production circuit
OTS

1 circuit without mixing valve


1 circuit with mixing valve
1 DHW production circuit

with indoor/outdoor system control


with domestic hot water production and pump output
with boiler pump output
with compiled fault output (dry contact)
with 0-10 VDC input
with adjustable high limit and fixed high limit
with space heating circuit switch
with power indication, call for heat indication,
and burner/FHL fault indication
with the Viessmann quick-connect plug-in system

Vitotronic 200, KW2


for multiple temperature heating systems
Indoor/outdoor, digital boiler and heating system control
with digital tracking of day and week
with programmable time periods, heating
curves, temperature setpoints and operating programs
with DHW production management (sensor included)
with integrated diagnostic system
with adjustable high limit and fixed high limit
with FHL test switch
with power indication and sensor/burner fault indication
with the Viessmann quick-connect plug-in system

ffBoiler standard working pressure: 30 psig; maximum working pressure: 45 psig.


For 45 psig, order optional pressure relief valve 9549 944, List Price $35..
An Order No. is supplied for each possible configuration, so all necessary components may easily be ordered together.
To order Vitotronic 100, KW10B separately 7834 238, List Price $848.To order Vitotronic 200, KW2 separately Z001 230, List Price $1863.To order Vitotronic 300, KW3 separately Z001 231, List Price $2133.Standard Equipment of Boiler:
Boiler shell (insulation preinstalled up to size -33), combustion chamber insert, installation fittings c/w 30 psig pressure relief
valve, drain valve, Tridicator, boiler control (above), burner wiring harness, burner (above) c/w correct oil nozzle

Control
Option

Burner
Option
VR1-22

VR1-27

VR1-33

VR1-40

VR1-50

VR1-63 Model No.

Hydrolevel

No Burner

VR10319
1,741.

VR10320
1,952.

VR10321
2,105.

VR10322
2,438.

VR10323
2,760.

VR10324 Order No.


3,091. US$

Hydrolevel

Beckett Oil for


Chimney Venting

VR10307
2,409.

VR10308
2,620.

VR10309
2,773.

VR10310
3,106.

VR10311
3,399.

VR10312 Order No.


3,730. US$

Hydrolevel

Beckett Oil
for Direct Venting

VR10295
3,484.

VR10296
3,695.

VR10297
3,848.

Hydrolevel

Riello Oil for


Chimney Venting

VR10313
2,638.

VR10314
2,849.

VR10315
3,020.

Hydrolevel

Riello Oil
for Direct Venting

VR10304
3,980.

VR10305
4,191.

VR10306
4,379.

Vitotronic 100,
KW10B

Beckett Oil for


Chimney Venting

VR10223
3,280.

VR10224
3,491.

VR10225
3,644.

Vitotronic 100,
KW10B

Beckett Oil
for Direct Venting

VR10235
4,355.

VR10236
4,566.

VR10237
4,719.

Vitotronic 100,
KW10B

Riello Oil for


Chimney Venting

VR10229
3,509.

VR10230
3,720.

VR10231
3,891.

Vitotronic 100,
KW10B

Riello Oil
for Direct Venting

VR10238
4851.

VR10239
5062.

VR10240
5250.

N/A

N/A

N/A

Vitotronic 200,
KW2

Beckett Oil for


Chimney Venting

VR10151
4,295.

VR10152
4,506.

VR10153
4,659.

VR10154
4,990.

VR10155
5,283.

VR10156 Order No.


5,614. US$

Vitotronic 200,
KW2

Beckett Oil
for Direct Venting

VR10190
5370.

VR10191
5581.

VR10192
5734.

N/A

N/A

N/A

Vitotronic 200,
KW2

Riello Oil for


Chimney Venting

VR10175
4,524.

VR10176
4,735.

VR10177
4,906.

VR10178
5,237.

VR10179
5,559.

VR10180 Order No.


6,119. US$

Vitotronic 200,
KW2

Riello Oil for


Direct Venting

VR10202
5,866.

VR10203
6,077.

VR10204
6,265.

N/A

N/A

N/A

91
80

105
92

140
122

161
140

196
172

38
976
19
500
33
840

44
1116
19
500
33
840

44
1116
19
500
33
840

36
914
221/4
565
393/4
1010

371/2
956
221/4
565
393/4
1010

421/2
1081
221/4
565
393/4
1010

9.2
35

11.6
44

11.6
44

12.7
48

16.1
61

19.3 USG
73 ltr

N/A

N/A

VR10316
3,353.

N/A

VR10317
3,675.

N/A

N/A

VR10226
3,975.

N/A

VR10232
4,222.

VR10318 Order No.


4,235. US$
N/A

VR10227
4,268.

N/A

Order No.
US$

Order No.
US$

VR10228 Order No.


4,599. US$
N/A

VR10233
4,544.

Order No.
US$

VR10234 Order No.


5,104. US$
Order No.
US$

Order No.
US$

Order No.
US$

Specifications
MBH

Input
Output

Dimensions
(incl. burner)

Boiler Length
Boiler Width
Boiler Height

Boiler Water Content

Boiler Vent Connection


Weight (Shipping) Boiler package

442
200

This trademark is registered with the U.S. Patent and Trademark Office.

6
508
230

508
230

564
256

245 MBH
215
inches
mm
inches
mm
inches
mm

inches
694
315

822 lbs
373 kg

Vitorond
100

VITOROND 100

VITOROND 100
Controls and Accessories

Controls

Multiple Boiler Applications


Vitocontrol-S

7134 632
4,148.

Order No.
US$

Power Supply Adaptor

7134 560
174.

Order No.
US$

LON Communication Module for data exchange with Vitocontrol Cascade


or other LON-compatible supervision system.
(order 1 unit per boiler)

7834 357
436.

Order No.
US$

LON Connection Terminal to convert standard LON cable of Vitocontrol-S


to 2-wire communication used in Vitotronic 100.
(order 1 unit per Vitocontrol-S)

7134 631
110.

Order No.
US$

Lead-Lag Expansion Kit (single-stage boilers only)


for load-dependent staging of a second boiler.
First boiler must be equipped with either Vitotronic 200/300.
Second boiler must be equipped with Vitotronic 100 KW10B.

7133 897
611.

Order No.
US$

Output Module (potential-free contact) for burner


status, burner failure, high boiler temperature, and
external (LWCO) alarm via LON.
(Order one per boiler; max.:4)

7134 562
695.

Order No.
US$

Switching Module-V to expand the capabilities of Vitotronic 200 and 300


via:
remote burner enable and disable
providing for additional heat demand (pool, spa, snowmelt, etc)
using with an external contact or Telephone Interface Module to
remotely change heating/operating mode of the heating circuit

7133 387
272.

Order No.
US$

Telephone Interface Module


necessary to operate heating system via telephone communication
(Switching Module-V also required)

9543 421
1,004.

Order No.
US$

KM-BUS Expansion Module


to connect up to 9 devices to the single KM-BUS connection
of the boiler control (Vitotrol, Switching Module-V, etc.)

7133 393
108.

Order No.
US$

Vitotronic Retrofit Housing for RN (SS)

7133 923
344.-

Order No.
US$

Vitotronic Retrofit Housing for RN (TS)

7133 923
483.-

Order No.
US$

Vitotronic Retrofit Housing for RS/AR

7133 925
250.-

Order No.
US$

Vitotronic Retrofit Housing for VBC/VNE/BEA

7133 922
214.-

Order No.
US$

Cascade Control

Digital outdoor reset boiler and heating system control.


Master control for up to 4 boilers, controlling two heating circuits
with mixing valve and domestic hot water production
Each boiler must be equipped with Vitotronic 100, KW10B
LON-enabled for multiple boiler installations

4 boilers max.
2 heating circuits
with mixing valve max.
DHW production

Communication

Expandability

VITOROND 100
Controls and Accessories

Vitorond
100

Accessories

Vitorond 100
7542 257
225.

Mixing Valve Actuator


Mixing Valve Controller Accessory Kit
to control a single heating circuit with one mixing valve; includes:
mixing valve motor to operate 3/4 to 21/2 Viessmann mixing valves
supply temperature sensor
VR1-22
Boiler Stand for Vitorond 100
9" / 250 mm height

VR1-27

7133 073
162.

VR1-33

7133 074
162.

VR1-40

VR1-50

7133 075
162.

OrderNo.
US$

VR1-63 Model No.

7133 076
174.

Order No.
US$

DHW Pump Module


for Vitorond 100 with Hydrolevel
control

9543 430
559.

Order No.
US$

Wiring Harness
to integrate Tjernlund Combustion
Air In-ForcerTM (field supplied) with
Vitotronic control

7133 921
87.

Order No.
US$

7189 602
Net price 78.

Carrying Handles

Order No.
US$

9521 645
Net price 1,413.

Two-Wheel Truck
Special two-wheel truck for
Viessmann boilers and domestic
hot water tanks
Transport Panel
For use with Viessmann
Two-Wheel Truck (above)

N/A

7198 575
Net price 102.

Order No.
US$

N/A

Order No.
US$

Remote Controls
Vitotrol 200 Remote Control for a single heating circuit to program:
daytime temperature and operating program;
with party and energy-saving button
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)
If the Vitotrol 200 is to operate based upon room-dependent activation, ensure placement in a centralized location.

7438 363
162.

Order No.
US$

Vitotrol 300A Remote Control for a single heating circuit to program:


daytime and nighttime temperature, DHW temperature, operating and holiday program,
party and energy-saving features
switching times for heating circuit, DHW tank and recirculation pump
with illuminated display and textual prompts
with room temperature sensor for room-dependent activation (for heating circuit with mixing valve only)
If the Vitotrol 300 is to operate based upon room-dependent activation, ensure placement in a centralized location.

7172 619
272.

Order No.
US$

Room Temperature Sensor


if the Vitotrol cannot be installed in a centralized location
(must be sold with Remote Control RS, Vitotrol 200, or Vitotrol 300)

7133 379
121.

Order No.
US$

This trademark is registered with the U.S. Patent and Trademark Office.

NOTES

VITODENS 100-W

Vitodens
100-W

Gas-fired, stainless steel condensing boiler


37 to 118 MBH / 11 to 35 kW

CombiPLUS Kit

Vitodens 100-W
WB1B Series
Gas-/Propane-Fired Wall-Mounted Condensing Boiler
with modulating stainless steel MatriX cylinder burner
stainless steel Inox-Radial heat exchanger
for room air dependent operation
or room air independent operation.
CombiPLUS Kit provides reliable on demand hot water without a
DHW tank.
Heating input: 37 to 118 MBH

11 to 35 kW

This trademark is registered with the U.S. Patent and Trademark Office.

Lasting Performance with industry leading Viessmann made


SA240 316 Ti stainless steel Inox-Radial heat exchanger constructed
to CSA B51 and ASME Section IV.
Low-Emission Combustion with Viessmann made stainless
steel MatriX cylinder burner for natural gas or propane. Factory
calibrated.
Versatile On-Board Boiler Control interfaces with most external
controls. Now with integrated OpenTherm and optional 0-10V
communication ability. Outdoor temperature sensor standard.
Greater Venting Flexibility with increased vent length
(up to 200 ft. / 61m) and multiple venting options:
--Horizontal or vertical sealed combustion coaxial venting.
--Horizontal, vertical or hybrid sealed combustion double-pipe
venting.
--Horizontal or vertical single-wall venting.
Altitude Levels of up to 10000 ft. / 3000 m.
Easy Installation, Service and Maintenance with all pipe connections
located at the bottom and serviceable components easily accessible
from the front.
Limited Lifetime Warranty in residential applications.

VITODENS 100-W

Vitodens 100-W
WB1B
26

WB1B
35

Model No.

WB1B500 WB1B501 Order No.

Vitodens 100-W

Input Range

Output Range

List Price
CombiPLUS Kit
to provide reliable on demand hot
water without a DHW tank
List Price

37-91
11-27

37-118 MBH
11-35 kW

34-83
10-24

34-108 MBH
10-32 kW

2,884.

3,193. US$

7459 305
CombiPLUS Kit only for use with boilers
WB1B500, WB1B501 above!

Specifications

515.
WB1B
26

Dimensions
excluding Length
CombiPLUS Kit
Width

Order No.
US$

WB1B
35

141/8
360
153/4
400
281/2
725

Height

Boiler Vent Connection


flue gas / fresh air

23/8 / 4
60/100

Shipping Weight
boiler (incl. fittings)
excluding vent system

95
43

CombiPLUS Kit
CombiPLUS Kit
DHW Supply Temperature

141/8
360
153/4
400
281/2
725

inches
mm
inches
mm
inches
mm

23/8 / 4 inches
60/100 mm
95 lbs
43 kg
31
14

lbs
kg

140
60

F
C

Continuous draw rate


with DCW temp. of 56F / 13C

99
374

147 USG/h
556 L/h

Continuous draw rate


at delta t= 63 F / 35K

156
589

216 USG/h
800 L/h

ffBoiler standard working pressure: 30 psig; maximum: 45 psig. For 45 psig, order optional PRV 9549 944, List Price $35..
ffBoiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.
Boiler Standard Equipment:
Wall-mount boiler and installation fittings c/w 30 psig
pressure relief valve, pressure gage, gas shut-off
valve, two fill/drain valves, all mounting hardware,
supplied analog temperature gauge
outdoor temperature sensor, and LP conversion kit.
CombiPLUS Standard Equipment:
Plate type heat exchanger,
built-in diverting valve,
built-in Grundfos 3-speed pump,
built-in pressure by-pass valve,
built-in water hammer arrester,
built-in flow sensor,
built-in temperature sensor,
supplied with 150 psig pressure relief valve.

10

ffThe products above utilize the OpenTherm communication protocol,


and are therefore only suitable for use with Vitodens 100-W.

VITODENS 100-W
Controls and Accessories

Accessories
WB1B
26

WB1B
35

Model No.

7416 056
322.

Order No.
US$

7416 058
538.

Order No.
US$

Versatronik 200
to control up to 8 Vitodens 100-W featuring:
load-dependent boiler activation and modulation via OpenTherm communication
menu-driven LCD display
indoor/outdoor control operation
control of 2 mixing valve actuators
control of 2 circulation pumps
domestic hot water production
includes 2 x CoCo OT adaptors 7416 060 (for boilers 1 and 2)
dimensions: W 91/2 / 241mm
H 8 / 210mm
D 2 / 64mm

7416 059
1,642.

Order No.
US$

CoCo OT Adaptor
OpenTherm adaptor for use with Versatronik 200 only
(order 1 unit for each of boilers 3 through 8)

7416 060
284.

Order No.
US$

Mixing Valve Adaptor, 24V or 120V


to operate up to 2 mixing valve actuators. Important: both mixing valve actuators must be either
24V or 120V - not mixed.
Includes 1 strap-on sensor, and 1 immersion sensor. (max. 1 unit per Versatronik 200)
Viessmann mixing valve actuator: 7542 257

7416 061
85.

Order No.
US$

Versatronik Lago OT for use with Versatronik 200 only


with display for weather-, space-, or time-oriented control of the room temperature
dimensions: W 31/4 / 83mm
H 31/4 / 83mm
(max. 2 units per Versatronik 200)
D 11/2 / 38mm

7416 062
284.

Order No.
US$

Input Module 0-10V OT


OpenThermTM input module, to enable a boiler reset module
controller to communicate with the Vitodens 100-W via
0-10V (DC) modulating input signal (order 1 until per boiler).

7249 069
256.

Order No.
US$

Versatronik Como OT
digital room temperature control featuring:
comfort button to adjust room temperature
7-day timer with 3 settings per day
party mode and energy-saving mode
99-day holiday mode, and more.
dimensions: W 53/4 / 146mm
H 4 / 102mm
D 11/2 / 38mm

(max. 1 unit per boiler; compatible with


outdoor temperature sensor supplied
with boiler)

Versatronik 10.WB1
DHW pump module to manage domestic hot water production for Vitodens 100-W
with one indirect fired storage tank
(max. 1 unit per boiler/tank combination;
dimensions: W 61/2 / 165mm
aquastat 1 or set-point control must be
H 81/4 / 210mm
field supplied)
D 21/2 / 64mm

Multiple Boilers

ffThe products above utilize the OpenTherm communication protocol, and are therefore only suitable for use with Vitodens 100-W.
1
Aquastat may be ordered from Viessmann 9560 985, List Price $142..

This trademark is registered with the U.S. Patent and Trademark Office.

11

Vitodens
100-W

Single Boilers

VITODENS 100-W

Controls and Accessories

Vitodens 100-W
Model No.

Accessories
9560 860
40F
UPS15-58FC
225.

Order No.

9544 425
31.

Order No.
US$

Model 80/60 Low-Loss Header


with insulation
Max. flow rate 19.5 USGPM / 4.4 m3/hr

7498 529
290.

Order No.
US$

Model 120/80 Low-Loss Header


with insulation
Max. flow rate 35 USGPM / 8 m3/hr

7498 530
435.

Order No.
US$

Neutralization Unit
with granular neutralization pellets

7134 231
368.

Order No.
US$

Neutralization Pellets
for replacement purposes
(2 x 2.9lbs / 1.3kg)

9524 670
76.

Order No.
US$

9537 070
Net Price 121.

Order No.
US$

7522 985
2,240.

Order No.
US$

Circulation Pump 1
Boiler delta T
Grundfos 3-speed, flanged
housing circulation pump, 115V
Flange Set, 11/4
(Others available, please inquire)

Model
US$

Low-Loss Headers 2
to decouple high flow rate systems from the boiler loop.

Service Tool Set


for Vitodens boilers
Service Kit
for Vitodens boilers models (WB1A, WB1B, WB2A, WB2B)

2
1

For Low-Loss Header sizing, please see Technical Data Manual.


Separate circulation pump required for each boiler. Select based upon system pressure drop and flow rate requirement
See technical data manual. Many other circulation pumps available please inquire.

12

VITODENS 100-W
Coaxial PP(s) Vent System

Vent System Diameter


60/100

Horizontally Vented

Maximum Equivalent
Length (EqL)

Room Air
Independent Operation

Basic Horizontal Vent Kit


Venting pieces can be ordered
individually, or as a convenient
kit using the Order No. to the
right; Basic Vent Kit includes
one of each of the items
numbered
to
,
.
and two Mounting Clips
Boiler Vent Pipe Adaptor
60/100

82 / 25
ft / m
7424 119
413.

80/125
98 / 30
ft / m

100/150

Diameter

118 / 36
ft / m

ft. / m

7424 120 7424 121 Order No.


460.
817. US$

included with boiler


N/A

7424 112
100.

Adaptor, coaxial
60/100 to 100/150

N/A

N/A

90 Elbow
EqL = 1.6ft. / 0.5m

7424 094
67.

7424 095 7424 096 Order No.


100.
144. US$

Straight Pipe 2
3.3ft. / 1m

7424 091
76.

7424 092 7424 093 Order No.


100.
121. US$

Vent Termination
2.6ft. / 0.8m

7424 100
144.

7424 101 7424 102 Order No.


162.
174. US$

Adaptor, coaxial
60/100 to 80/125

N/A

Order No.
US$

not shown

not shown

Protective Screen 1

Order No.
US$

7424 109
16.10

7424 110 7424 111 Order No.


20.
26. US$

Sliding Coupling
1.25ft. / 0.4m

7424 106
67.

7424 107 7424 108 Order No.


76.
87. US$

Straight Pipe 2
1.6ft. / 0.5m

7424 088
52.

7424 089 7424 090 Order No.


67.
100. US$

45 Elbow (Set of 2)
EqL = 1.0ft. / 0.3m

7424 097
121.

7424 098 7424 099 Order No.


135.
191. US$

Mounting Clip 2 (each)


Other Available Vent Pieces
not shown in illustration above

7160 616
77.

7424 113 Order No.


162. US$

PP(s) coaxial vent material must be ULC S-636 certified for Category IV boilers. Do not mix non-ULC S-636 with ULC S-636 venting.
Side wall venting installation must include Viessmann Protective Screen!
2
Order 1 Mounting Clip for each straight length of vent pipe installed.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.
1

This trademark is registered with the U.S. Patent and Trademark Office.

13

Vitodens
100-W

Vent System 1

VITODENS 100-W
Coaxial PP(s) Vent System

Vent System Diameter

Vent System 1

60/100
Maximum Equivalent
Length (EqL)

Vertically Vented

Room Air
Independent Operation

Boiler Vent Pipe Adaptor


60/100

Adaptor, coaxial
60/100 to 80/125

82 / 25
ft / m

80/125
98 / 30
ft / m

100/150
118 / 36
ft / m

Diameter
ft. / m

included with boiler

N/A

7424 112
100.

N/A

Order No.
US$

Adaptor, coaxial
60/100 to 100/150

N/A

N/A

7424 113 Order No.


162. US$

90 Elbow
EqL = 1.6ft. / 0.5m

7424 094
67.

7424 095
100.

7424 096 Order No.


144. US$

Mounting Clip 2 (each)

7424 109
16.10

7424 110
20.

7424 111 Order No.


26. US$

Sliding Coupling
1.25ft. / 0.4m

7424 106
67.

7424 107
76.

7424 108 Order No.


87. US$

Straight Pipe 2
1.6ft. / 0.5m

7424 088
52.
or
7424 091
76.

7424 089
67.
or
7424 092
100.

7424 090
100.
or
7424 093
121.

45 Elbow (Set of 2)
EqL = 1ft. / 0.3m

7424 097
121.

7424 098
135.

7424 099 Order No.


191. US$

Vent Termination
3.9ft. / 1.2m

7424 103
256.

7424 104
350.

7424 105 Order No.


435. US$

not shown

not shown

Straight Pipe 2
3.3ft. / 1m

A Combustion Air Intake


B Flue Gas Outlet

Roof Flashing
and Storm Collar
(B-Vent material or better)

Order No.
US$
Order No.
US$

field
supplied

PP(s) coaxial vent material must be ULC S-636 certified for Category IV boilers. Do not mix non-ULC S-636 with ULC S-636 venting.
Order 1 Mounting Clip for each straight length of vent pipe installed.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.

1
2

14

VITODENS 100-W
Vent Systems

Alternative Vent Systems

Boiler Flue Gas Connection


80

60/100

Coaxial Venting 1 see page 14

100

80/125

Diameter

100/150

Vitodens
100-W

60

direct-connect venting
- no special adaptors required
Protective Screen
(for side wall installations only)
60

Rigid and Flexible PP(s) Venting 1






for Combustion Air Intake 4


(only if installing ABS, CPVC or
PVC piping for combustion air
intake, please order one CPVC
Adaptor per boiler)

Adaptor, CPVC
60mm to 2

for Combustion Air Intake 4 and


for Flue Gas Outlet

Adaptor, CPVC
60mm to 2
Adaptor
2 to 3 or 3 to 4

for Combustion Air Intake 4

for Flue Gas Outlet

2x
7134 769
7.90

80

Order No.
US$
100

Diameter

7134 769
7.90

7134 769 Order No.


7.90 US$

field
supplied

field Order No.


supplied US$

Diameter

2x
7134 769
7.90

2 x Qty
7134 769 Order No.
7.90 US$

field
supplied

field Order No.


supplied US$

Stainless Steel Venting 3


7134 769
7.90

Adaptor
2 to 3 or 3 to 4

CPVC Venting 2

7160 616
77.

Diameter

Adaptor, CPVC
60mm to 2

7134 769
7.90

7134 769 Order No.


7.90 US$

Adaptor
2 to 3 or 3 to 4

field
supplied

field Order No.


supplied US$

PP(s) Adaptor
for stainless steel
60mm to 80mm required

field
supplied

field Order No.


supplied US$

Coaxial and PP(s) vent material must be ULC S-636 certified for Category IV boilers. Suggested source: Centrotherm, or M&G Duravent.
CPVC vent material must be ULC/UL listed for Category IV boilers. Suggested source: IPEX Inc.
3
Stainless steel vent material must be ULC/UL listed for Category IV boilers.
Suggested sources: Flexmaster Canada Ltd. / Z-Flex (US) Inc., Heat-fab, M&G Duravent, or Security Chimneys International.
4
Combustion air supply pipe may be made of the following materials: PP(s), ABS, CPVC, or PVC.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.
1
2

This trademark is registered with the U.S. Patent and Trademark Office.

15

NOTES

16

VITODENS 200-W

Vitodens
200-W

Gas-fired, stainless steel condensing boiler


12 to 530 MBH / 3.5 to 155 kW

Vitodens 200-W
B2HA/B2HB Series
Wall-Mounted Condensing Boiler
with modulating MatriX-cylinder burner
for room air dependent operation
or room air independent operation
Heating input: 12 to 530 MBH

3.5 to 155 kW
For natural gas or liquid propane gas

This trademark is registered with the U.S. Patent and Trademark Office.

Lasting Performance with industry-leading Viessmann


made SA240 316 Ti stainless steel Inox-Radial heat
exchanger constructed to CSA B51 and ASME Section IV.
Fast Installation and Reduced Maintenance with Lambda
Pro, industry-first intelligent combustion management
system: Adjusts automatically to gas type and quality.
No fuel conversion kit required.
Expanded Application Range with increased capacity up
to 530 MBH (155 kW). Multi-boiler installation up to
4240 MBH (1240 kW) with up to 8 boilers
(models B2HA 45 - 150).
Extremely Quiet Operation; quieter than most refrigerators.

17

VITODENS 200-W

Vitodens 200-W
B2HB
19

B2HB
26

B2HB
35

B2HA
45

B2HA
60

B2HA
80

B2HA
100

B2HA
112

B2HA Model
150 No.

Single or Multiple
Boiler Installations
Vitodens 200-W with
Vitotronic 200 HO1B

List Price

B2HB007 B2HB008 B2HB009 B2HAA90 B2HAA91 B2HAA92 B2HAA93 B2HAA94 B2HAA95 Order No.

Input
Range

12-68
3.5-20

19-94
5.5-27

19-125
5.5-37

60-160
17-47

60-212
17-62

104-285
30-83

104-352
30-103

113-399
33-117

113-530 MBH
33-155 kW

Output
Range

10.9-64
3.2-19

17.4-88
5-26

17.4-117
5-34

55-146
11-43

55-194
11-57

95-260
28-76

98-333
29-96

103-375
30-110

103-495 MBH
30-145 kW

NG / LP

3,769.

3,957.

4,175.

4,999.

5,796.

7,205.

8,525.

9,572.

12,614. US$

153/4
400
173/4
450
41
1040

153/4
400
173/4
450
41
1040

153/4
400
173/4
450
41
1040

15
380
19
480
405/8
1031

15
380
19
480
405/8
1031

21
530
19
480
431/2
1105

21
530
19
480
431/2
1105

27
698
235/8
600
441/2
1128

27
698
235/8
600
441/2
1128

60/100

60/100

60/100

80/125

80/125

110/150

110/150

110/150

110/150

mm

30

30

30

30

30

30

30

80

80

psig

110
50

110
50

110
50

155
72

155
72

194
88

194
88

298
135

298
135

Technical Data
Dimensions
Length
Width
Height

Boiler Vent
Connection
flue gas / fresh air

Standard Pressure
Relief Valve

Shipping Weight
(incl. fittings)
not including
vent system

inches
mm
inches
mm
inches
mm

lbs
kg

Standard Equipment:
Wall-mount boiler, Vitotronic 200 HO1B, and installation fittings c/w 30 psig pressure relief valve, outdoor temperature sensor,
DHW Sensor, LLH Sensor and Double Pipe Adaptor (for B2HA 45-150) gas shut-off valve, two fill/drain valves, and mounting hardware.
ffBoiler standard working pressure:
30 psig up to B2HA 100
80 psig for B2HA 112/150;
For 30 psig, order optional PRV 9542 940, List Price $20.
For 45 psig, order optional PRV 9549 944, List Price $35..
For 60 psig, order optional PRV 9560 183, List Price $35.. (sizes B2HA 45 and up only)
ffBoiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.

18

VITODENS 200-W

Vitodens 200-W
B2HB
26

B2HB
35

B2HA
45

B2HA
60

B2HA
80

B2HA
100

B2HA
112

B2HA Model
150 No.

Single Boiler
Installation
with Floor Stand
Vitodens 200-W
with Vitotronic 200 HO1B
Input Range
Output Range
List Price

NG / LP

B2HB004 B2HB005 B2HB006 B2HAA99 B2HAB00 B2HAB01 B2HAB02 B2HAB03 B2HAB04 Order No.
12-68
3.5-20

19-94
5.5-27

19-125
5.5-37

60-160
17-47

60-212
17-62

104-285
30-83

104-352
30-103

113-399
33-117

113-530 MBH
33-155 kW

10.9-64
3.2-19

17.4-88
5-26

17.4-117
5-34

55-146
11-43

55-194
11-57

95-260
28-76

98-333
29-96

103-375
30-110

103-495 MBH
30-145 kW

3,948.

4,136.

4,354.

5,178.

5,975.

7,384.

8,704.

Boiler Stand
for free-standing
installation
of a single boiler
within the
mechanical room

7537 684
(Applies to B2HB 19-35 and B2HA 45-100)

9,773. 12,815. US$


7502 558
(Applies
to B2HA
112-150)

Order No.

ffBoiler standard working pressure:


30 psig up to B2HA 100
80 psig for B2HA 112/150;
For 30 psig, order optional PRV 9542 940, List Price $20.
For 45 psig, order optional PRV 9549 944, List Price $35..
For 60 psig, order optional PRV 9560 183, List Price $35.. (sizes B2HA 45 and up only)
ffBoiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.

This trademark is registered with the U.S. Patent and Trademark Office.

19

Vitodens
200-W

B2HB
19

VITODENS 200-W
Accessories

Accessories

Solar DHW Production and Supplemental Heating


Solar Module SM1
Wall-mounted extension module with electronic differential control for dualcoil DHW production and to supplement space heating using solar collectors
when used with oil/gas-fired heating boilers.
operation and display via boiler control
management of two tank systems from one collector field
second electronic differential control capability
thermostat function for supplemental heating or use of surplus heat
variable speed pump controller for solar circuit pump via pulse-width
control, or for solar circuit pump with PWM-input (mfg Grundfos)
includes one tank sensor and one collector sensor
120V, 60Hz, 2A in CSA housing, with 6.5 cord and 120V plug
to be used instead of an SCU Solar Controller

7533 427 Order No.


466. US$

Order immersion sensor 7438 702 if the following features are required:
for circulation management in systems with 2 storage tanks
for return flow management between boiler and hot water buffer tank
to supply heat to additional accessories

7438 702 Order No.


87. US$

Communication
Vitogate 300, BN/MB Series
configured as compact wall-mount unit
-dimensions
W 6
H 8
D 8

7559 706 Order No.


1,380.- US$

-120V, 60Hz, 1A, with 6.5 cord and 120V pkg


LON Connecting Cable, 23ft / 7m
for data exchange between controls

7143 495 Order No.


52. US$

LON Extension Jack


to extend LON Connecting Cable

7143 496 Order No.


34. US$

LON Connecting Terminal (RJ, 2 Pieces)


to connect to field cabling via wall-mount boxes

7171 784 Order No.


76. US$

LON Terminal Resistor (2 Pieces)


to terminate the system BUS, a resistor must be installed on each free end

7143 497 Order No.


14. US$

LON Communication Module


electronic circuit board enabling data communication via Viessmann LON
system BUS. For installation inside Vitodens 200-W.

7179 113 Order No.


328. US$

Expanded Functions
Extension Module AM1
wall-mounted extension module controls up to 2 of the following circulation
pumps:
DHW recirculation pump
DHW production pump
heating circuit pump for the circuit without a mixing valve
120V, 60Hz, 4A in CSA housing, with 6.5 / 2m cord and 120V plug
Each boiler must be equipped with 1X 7179 113 LON Communication Module.

20

7533 425 Order No.


334. US$

VITODENS 200-W
Accessories

Accessories
B2HB
19

B2HB
26

B2HB
35

B2HA
45

B2HA
60

B2HA
80

B2HA
100

B2HA
112

B2HA
150

Model
No.

Circulation Pump 1
Boiler delta T
Grundfos 3-speed,
flanged
housing circulation
pump, 115V
Flange Set, 1
(Others available,
please inquire)

Low-Loss Header
with Insulation
to decouple
high flow rate
systems from
the boiler loop

7248 585
40F
UPS 26-99FC
391.

7441 596
40F
UPS 26-150FC
611.-

Max. Flow

Neutralization System
to neutralize acidic
condensate
includes pellets

80/60

120/80

19.5 USGPM
4.4 m3/hr

35 USGPM
8 m3/hr

7498 529
290.

7498 530
435.

Neutralization Granulate

Model

Order No.
US$

Order No.
US$

7179 488
121.
included with boiler

7134 231
368.

Model
US$

Order No.
US$

31. For all sizes


9544 425

LLH Temperature Sensor


(Immersion) to measure the
temperature inside a low-loss
header

Order No.

9560860
40F
UPS 15-58FC
225.

7134 232
413.

7441 823
424.

Order No.
US$

9524 670
5.7 lbs / 2.6 kg
76.

9521 702
18 lbs / 8 kg
89.

Order No.
US$

Separate circulation pump required for each boiler.


Select based upon system pressure drop and flow rate requirement - see Vitodens Technical Data Manual.
Many other circulation pumps available - please inquire.

This trademark is registered with the U.S. Patent and Trademark Office.

21

Vitodens
200-W

Heating Circuit

VITODENS 200-W
Accessories

Accessories

Low-Temperature Heating Circuits


Mixing Valve Extension Kit consisting of:

ZK01105 Order No.


644. US$

Mixing Valve Module (KM-BUS participant, wall mount)


including supply temperature sensor (strap-on)
plugs for circulation pump and mixing valve motor
KM-BUS cable
120V, 60Hz, 2A in CSA housing, with 6.5 / 2m cord and 120V plug
Mixing Valve Motor, 120/1/60
for Viessmann 3- and 4-way mixing valves only
including strap-on supply temperature sensor (NTC 10 kOhm)
Maximum 2 Mixing Valve Extensions per Vitodens boiler in single boiler
applications

Mixing Valves
Viessmann 3-Way Mixing Valves

3/4
7134 742
308.

1
7134 743
328.

11/4
7134 744
368.

11/2
7134 745
413.

2
7134 746
506.

Dia
Order No.
US$

Sensors
Room Temperature Sensor (wall mount, NTC 10 kOhm)
for use with Vitotrol 300A
Order Room Temperature Sensor if Vitotrol 300A cannot be installed
in a centralized location to measure room temperature.

DHW Temperature Sensor


to measure the temperature inside a domestic hot water storage tank

22

7438 537 Order No.


108. US$

Included
with boiler

7179 114 Order No.


121. US$

VITODENS 200-W
Accessories

Accessories

Vitotrol 200A
(KM-BUS protocol)
User interface to operate one heating circuit:
daytime temperature and operating program
with party and energy-saving button
display indication of outside temperature, room temperature and operational settings
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)

7438 363 Order No.


162. US$

If the Vitotrol 200A is to operate based upon room-dependent activation,


ensure placement in a centralized location.
Maximum 2 Vitotrols per Vitotronic.

Vitotrol 300A
(KM-BUS protocol)
User interface to operate one, two or three heating circuits:
daytime temperature, set-back temperature, DHW temperature, operating and holiday
program, as well as party and energy-saving function
timer program for heating circuits, DHW production, and DHW recirculation pump
illuminated graphic display to show outdoor temperature, room temperature,
operational settings together with descriptive texts
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)

7172 619 Order No.


272. US$

If the Vitotrol 300A is to operate based upon room-dependent activation,


ensure placement in a centralized location.
Order Room Temperature Sensor 7438537 if the Vitotrol 300 cannot be installed
in a centralized location.
Maximum 2 Vitotrols per Vitotronic.

Other
Wall-Mount Base
to reposition the programming unit outside of the Vitotronic
mounting base
blind cover
connection cable

7299 408 Order No.


108. US$

KM-BUS Distributor
to connect between 2 and 9 additional devices to the KM-BUS

7133 393 Order No.


108. US$

OT/KM-Bus Module
to convert the Viessmann KM-Bus signal to OpenThermTM
120V, 60Hz in CSA housing, with 6.5 / 2m cord and 120V plug

7533 428 Order No.


414. US$

Order 1 unit per boiler.

Service
Service Tool Set
for Vitodens boilers

This trademark is registered with the U.S. Patent and Trademark Office.

9537 070 Order No.


Net Price
121. US$

23

Vitodens
200-W

Remote Controls

VITODENS 200-W
Coaxial PP(s) Vent System

Vent System
Diameter

Horizontally Vented

Maximum Equivalent Length (EqL)

B2HB
19

B2HB
26

B2HB
35

B2HA
45

B2HA
60

B2HA
80

B2HA
100

B2HA
112

B2HA
150

60/100

33 ft/
10 m

33 ft/
10 m

33 ft/
10 m

N/A

N/A

N/A

N/A

N/A

N/A

80/125

40 ft/
12 m

40 ft/
12 m

40 ft/
12 m

33 ft/
10 m

20 ft/
6m

N/A

N/A

N/A

N/A

100/150

50 ft/
15 m

50 ft/
15 m

50 ft/
15 m

43 ft/
13 m

30 ft/
9m

50 ft/
15 m

50 ft/
15 m

26 ft/
8m

16 ft/
5m

Room Air
Independent Operation

Basic Horizontal Vent Kit


Venting pieces can be ordered
individually, or as a convenient
kit using the Order No. to the
right; Basic Vent Kit includes
one of each of the items
numbered 1 to 5, and two
Mounting Clips 6.

Important!
As a starting point,
please pay attention to
boiler vent connection size
shown above

Boiler Vent Pipe Adaptor

7424 119
413.

Model
No

7424 120 7424 121 Order No.


460.
817. US$

included with boiler

1 Flue Transition

7424 115 Order No.


87. US$

110/150 to 100/150 only

N/A

N/A

Adaptor, coaxial
60/100 to 80/125

N/A

7424 112
100.

N/A

N/A

7424 113 Order No.


162. US$

N/A

N/A

7424 114 Order No.


121. US$

not shown - required B2HA 80...150

N/A

Order No.
US$

not shown - only for B2HB 19/26/35

1 2

3 6

Adaptor, coaxial
60/100 to 100/150
not shown - only for B2HB 19/26/35

A
B
A

Adaptor, coaxial
80/125 to 100/150

not shown - only for B2HA 45/60

2 90 Elbow

EqL = 1.6ft. / 0.5m

3 Straight Pipe 2
3.3ft. / 1m

4 Vent Termination
2.6ft. / 0.8m

A Combustion Air Intake


B Flue Gas Outlet

7424 094
67.

7424 095 7424 096 Order No.


100.
144. US$

7424 091
76.

7424 092 7424 093 Order No.


100.
121. US$

7424 100
144.

7424 101 7424 102 Order No.


174. US$
162.

5 Protective Screen 1
6 Mounting Clip 2 (each)

7160 616
77.
7424 109
16.10

Order No.
US$

7424 110 7424 111 Order No.


20.
26. US$

PP(s) coaxial vent material must be ULC S-636 certified for Category IV boilers. Do not mix non-ULC S-636 with ULC S-636 venting.
Side wall venting installation must include Viessmann Protective Screen!
2
Order 1 Mounting Clip for each straight length of vent pipe installed.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.
1

24

VITODENS 200-W
Coaxial PP(s) Vent System

Vertically Vented

Maximum Equivalent Length (EqL)

B2HB
19

B2HB
26

B2HB
35

B2HA
45

B2HA
60

B2HA
80

B2HA
100

B2HA
112

B2HA
150

60/100

33 ft/
10 m

33 ft/
10 m

33 ft/
10 m

N/A

N/A

N/A

N/A

N/A

N/A

80/125

40 ft/
12 m

40 ft/
12 m

40 ft/
12 m

33 ft/
10 m

20 ft/
6m

N/A

N/A

N/A

N/A

100/150

50 ft/
15 m

50 ft/
15 m

50 ft/
15 m

43 ft/
13 m

30 ft/
9m

50 ft/
15 m

50 ft/
15 m

26 ft/
8m

16 ft/
5m

Boiler Vent Pipe Adaptor

Room Air
Independent Operation

Important!
As a starting point,
please pay attention to
boiler vent connection size
shown above

1 Flue Transition

110/150 to 100/150 only

included with boiler

11

Adaptor, coaxial
60/100 to 80/125

7424 115 Order No.


84. US$

N/A

N/A

N/A

7424 112
100.

N/A

N/A

7424 113 Order No.


162. US$

N/A

N/A

7424 114 Order No.


121. US$

7424 094
67.

7424 095
100.

7424 096 Order No.


144. US$

7424 109
16.10

7424 110
20.

7424 111 Order No.


26 US$

7424 106
67.

7424 107
76.

7424 108 Order No.


87. US$

7424 088
52.
or
7424 091
76.

7424 089
67.
or
7424 092
100.

7424 090
100.
or
7424 093
121.

7424 097
121.

7424 098
135.

7424 099 Order No.


191. US$

7424 103
256.

7424 104
350.

7424 105 Order No.


435. US$

not shown - required B2HA 80...150

Model
No

Vitodens
200-W

Vent System
Diameter

N/A

Order No.
US$

not shown - only for B2HB 19/26/35

12

Adaptor, coaxial
60/100 to 100/150
not shown - only for B2HB 19/26/35

Adaptor, coaxial
80/125 to 100/150

not shown - only for B2HA 45/60

2 90 Elbow

EqL = 1.6ft. / 0.5m

6
10

1 2

6 8

9
6

10
9
2

6 Mounting Clip 2 (each)


8 Sliding Coupling
1.25ft. / 0.4m

9 Straight Pipe 2
1.6ft. / 0.5m

Straight Pipe 2
3.3ft. / 1m

10 45 Elbow (Set of 2)
A Combustion Air Intake
B Flue Gas Outlet

EqL = 1.0ft. / 0.3m

11 Vent Termination
3.9ft. / 1.2m

12 Roof Flashing

and Storm Collar


(B-Vent material or better)

Order No.
US$
Order No.
US$

field
supplied

PP(s) coaxial vent material must be ULC S-636 certified for Category IV boilers. Do not mix non-ULC S-636 with ULC S-636 venting.
Order 1 Mounting Clip for each straight length of vent pipe installed.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.

1
2

This trademark is registered with the U.S. Patent and Trademark Office.

25

VITODENS 200-W
Alternative Vent Systems

Alternative Vent Systems

Boiler Flue Gas Connection


60
See previous 2 pages

Coaxial Venting 1

Rigid and Flexible PP(s) Venting 1


B2HA/B2HB
19 to 150

for Combustion Air Intake 4

B2HA 45 to 60

for Combustion Air Intake 4 and


for Flue Gas Outlet

B2HA 80 to 150

for Combustion Air Intake 4 and


for Flue Gas Outlet

If installing ABS, CPVC or PVC


piping for combustion air
intake, please order one CPVC
Adaptor per boiler

80

60/100

80/125

100/150

60

80

100

Diameter

80>3
7134 770
17.10

Double-Pipe Adaptor
80/125 to 80/80

N/A

7189 822
100.

Double-Pipe Adaptor
110/150 to 110/110

N/A

N/A

7373 253 Order No.


162. US$

Starter Adaptor 110/100

N/A

N/A

field Order No.


supplied US$

B2HB 19 to 35

for Combustion Air Intake 4 and


for Flue Gas Outlet

Adaptor, CPVC
60mm to 2

B2HA 45 to 60

for Combustion Air Intake 4 and


for Flue Gas Outlet

Double-Pipe Adaptor
80/125 to 80/80

Double-Pipe Adaptor
110/150 to 110/110

110>4 Size
7134 771 Order No.
26. US$
N/A

Order No.
US$

Diameter

2x
7134 769
7.90

2x
7134 769
7.90

2 x Qty
7134 769 Order No.
7.90 US$

N/A

7189 822
100.

7189 822 Order No.


100. US$

N/A

2x
7134 770
17.10

2 x Qty
7134 770 Order No.
17.10 US$

N/A

N/A

7373 253 Order No.


162. US$

Adaptor, CPVC
80mm to 3
for Combustion Air Intake 4 and
for Flue Gas Outlet

Diameter

60>2
7134 769
7.90

CPVC Venting 2

B2HA 80 to 150

100

2 x Qty
7134 771 Order No.
26. US$

Adaptor, CPVC
110mm to 4
3

Stainless Steel Venting 3

Diameter

B2HB 19 to 35

for Combustion Air Intake 4

Adaptor, CPVC
60mm to 2

N/A

7134 769
7.90

7134 769 Order No.


7.90 US$

for Flue Gas Outlet

Starter Adaptor, SS
2/3 or 2/4

N/A

field
supplied

field Order No.


supplied US$

B2HA 45 to 60

for Combustion Air Intake 4 and


for Flue Gas Outlet

Double-Pipe Adaptor
80/125 to 80/80

N/A

7189 822
100.

B2HA 80 to 150

for Combustion Air Intake 4 and


for Flue Gas Outlet

Double-Pipe Adaptor
110/150 to 110/110

N/A

N/A

7373 253 Order No.


162. US$

Starter Adaptor, PPs


80/3 or 110/4

N/A

field
supplied

field Order No.


supplied US$

N/A

Order No.
US$

Coaxial and PP(s) vent material must be ULC S-636 certified for Category IV boilers. Suggested source: Centrotherm, or M&G Duravent.
CPVC vent material must be ULC/UL listed for Category IV boilers. Suggested source: IPEX Inc.
3
Stainless steel vent material must be ULC/UL listed for Category IV boilers.
Suggested sources: Flexmaster Canada Ltd. / Z-Flex (US) Inc., Heat-fab, M&G Duravent, or Security Chimneys International.
4
Combustion air supply pipe may be made of the following materials: PP(s), ABS, CPVC, or PVC.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.
1
2

26

VITODENS 200-W

Vitodens
200-W

Gas-fired, stainless steel condensing boiler


320 to 4240 MBH / 94 to 1240 kW

Product may not be exactly as illustrated.

Vitodens 200-W
B2HA Series, multiple boiler
Gas-/Propane-Fired Wall-Mounted Condensing Boiler
with modulating MatriX-cylinder burner
for room air dependent operation
or room air independent operation
For natural gas or propane

This trademark is registered with the U.S. Patent and Trademark Office.

Viessmann Cascade Control for up to 8 boilers with heating input of


320 MBH to 4240 MBH
Lasting Performance with industry-leading Viessmann
made SA240 316 Ti stainless steel Inox-Radial heat
exchanger constructed to CSA B51 and ASME Section IV.
Low Emission Combustion with Viessmann made stainless steel
MatriX cylinder burner. Factory calibrated.
Powerful and User-Friendly Viessmann Vitotronic on-board
multi-function outdoor reset boiler and system control for multitemperature space and DHW heating.
Fast Installation and Reduced Maintenance with Lambda
Pro, industry-first intelligent combustion management
system: Adjusts automatically to gas type and quality.
No fuel conversion kit required.
Extremely Quiet Operation; quieter than most refrigerators.

27

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W

Multiple Boiler Installations

Vitodens 200-W

Config No.

Configuration Drawing (Top View)

Componentry

2 boilers
in- line

Manifold: 7537703 (1)


Fittings 1: 7535929 (2)
Fittings 2: 7535930 (1)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)

3 boilers
in- line

Manifold: 7537704 (1)


Fittings 1: 7535929 (3)
Fittings 2: 7535930 (1)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)

4 boilers
in- line

Manifold: 7537703 (2)


Fittings 1: 7535929 (4)
Fittings 2: 7535930 (2)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)

4 boilers
back to back

Manifold: 7537703 (2)


Fittings 1: 7535929 (4)
Fittings 2: 7535930 (2)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)
Y-Piece: 7537721 (1)
Adaptor: 7201963 (1)1

5 boilers
back to back

Manifold: 7537703 (1)


7537704 (1)
Fittings 1: 7535929 (5)
Fittings 2: 7535930 (2)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)
Y-Piece: 7537721 (1)
Adaptor: 7201963 (1)

6 boilers
back to back

Manifold: 7537704 (2)


Fittings 1: 7535929 (6)
Fittings 2: 7535930 (2)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)
Y-Piece: 7537721 (1)
Adaptor: 7201963 (1)1

7 boilers
back to back

Manifold: 7537703 (2)


7537704 (1)
Fittings 1: 7535929 (7)
Fittings 2: 7535930 (3)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)
Y-Piece: 7537721 (1)
Adaptor: 7201963 (1)1

8 boilers
back to back

Manifold: 7537703 (4)


Fittings 1: 7535929 (8)
Fittings 2: 7535930 (4)
Fittings 3: 7535931 (1)
LLH: sized as needed (1)
Y-Piece: 7537721 (1)
Adaptor: 7201963 (1)1

1 An adaptor set is only required if manifolds are connected directly to 400/200 LLH or larger; or if a Y-piece is connected to a LLH
smaller than 400/200

28

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W
Multiple Boiler Installations

Back to Back

Vitodens 200-W
Multiple Low Loss
Distribution Manifold
(MANIFOLD ONLY)

2 boilers
in-line

3 boilers
in-line

4 boilers
in-line

4 boilers
b-to-b

5 boilers
b-to-b

6 boilers
b-to-b

7 boilers
b-to-b

8 boilers
b-to-b

Configuration
Drawing No.

No. 1

No. 2

No. 3

No. 4

No. 5

No. 6

No. 7

No. 8

for B2HA 45

ZK01203
3,958.

ZK01204
4,646.

ZK01205
7,079.

ZK01206
8,912.

ZK01207
9,600.

ZK01208
10,528.

ZK01209
12,293.

ZK01210
14,966.

for B2HA 60

ZK01203
3,958.

ZK01211
4,860.

ZK01205
7,079.

ZK01206
8,912.

ZK01212
9,840.

ZK01208
10,528.

ZK01213
12,963.

ZK01214
15,182.

for B2HA 80

ZK01215
4,172.

ZK01211
4,860.

ZK01216
7,319.

ZK01217
9,152.

ZK01218
10,056.

ZK01219
10,744.

ZK01213
12,963.

ZK01220
15,237.

for B2HA 100

ZK01215
4,172.

ZK01221
5,100.

ZK01222
7,535.

ZK01223
9,368.

ZK01218
10,056.

ZK01224
10,799

ZK01225
13,018.

ZK01226
16,138.

for B2HA 112

ZK01215
4,172.

ZK01173
5,316.

ZK01222
7,535.

ZK01223
9,368.

ZK01176
10,111.

ZK01224
10,799.

ZK01178
13,919.

ZK01226
16,138.

for B2HA 150

ZK01172
4,412.

ZK01173
5,316.

ZK01174
8,542.

ZK01175
9,423.

ZK01176
10,111.

ZK01177
11,700

ZK01178
13,919.

ZK01179
16,629.

Vitodens
200-W

In-line



*BOILERS not included in the packages listed above

This trademark is registered with the U.S. Patent and Trademark Office.

29

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W

Sample Dimensions
7 boiler manifold
size B2HA 150 boiler
(maximum
dimensions given)

C D

A
F

Technical Data
A
91
2314

C
92
2352

D
16
420

LLH Size
9
229

160/80
200/120
250/150
300/200
400/200
450/250

All dimensions are


estimates as at 9/2013

30

500/300

F
19
486
19
500
21
550
23
600
27
700
33
850
35
900

G
45
1152

H
67
1712

75 inches
1920 mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm

VITODENS 200-W
Multiple Boiler Installations

Number of Boilers in Each Package

Vitodens 200-W

Vitodens 200-W

B2HA 45


Total Input

Total Output
Total Package List Price

B2HAB47 B2HAB48 B2HAB49 B2HAB50 B2HAB51 B2HAB52 B2HAB53 B2HAB54 Order No.
320
292
16,302.

480
438
22,174.

640
584
29,658.

640
584
31,140.

800
730
37,012.

960
876
43,106.

1120
1022
50,392.

1280 MBH
1168 MBH
57,679.

Vitodens
200-W

Multiple Boiler Installations

Total Package consists of the items listed below


Vitodens 200-W

B2HA 45

2x
3x
B2HAA90 B2HAA90

4x
B2HAA90

5x
6x
7x
8x Qty
B2HAA90 B2HAA90 B2HAA90 B2HAA90 Blr Model
Order No.

1x
7202 856 Applicable for all sizes

Vitotronic 300-K, MW2C


Cascade control for up to 8 boilers

Qty
Order No.

KMK BUS Communication Module


Required for each Viessmann
Boiler controlled by cascade
control

2x
7441 586

3x
7441 586

4x
7441 586

5x
7441 586

6x
7441 586

7x
8x Qty
7441 586 7441 586 Order No.

Circulation Pump
UPS 26-99FC 120/1/60

2x
7248 585

3x
7248 585

4x
7248 585

5x
7248 585

6x
7248 585

7x
8x Qty
7248 585 7248 585 Order No.

Neutralization System
To neutralize acidic condensate,
includes pellets
CSD-Conversion Kit

2x
7841 861

3x
7841 861

Manifold 1

1x
7537 703

1x
7537 704

Manifold 2

Low Loss Header

Fittings 1

Fittings 2

Qty
Order No.

1x
7441 823 Applicable for all sizes
4x
7841 861
2x
7537 703

2x
7535 929

3x
7535 929

1x
7535 930

Fittings 3

6x
7841 861

7x
8x Qty
7841 861 7841 861 Order No.

1x
7537 703

2x
7537 704

2x
4x Qty
7537 703 7537 703 Order No.

1x
7537 704

N/A
1x
7537 705
160/80

5x
7841 861

N/A

1x
7537 706
200/120
4x
7535 929

1x
7537 704
1x
7537 707
250/150

5x
7535 929

6x
7535 929

2x
7535 930

N/A

Qty
Order No.
Qty
Order No.

7x
8x Qty
7535 929 7535 929 Order No.
3x
4x Qty
7535 930 7535 930 Order No.

1x
7535 931 Applicable for all sizes

Qty
Order No.

Y-Piece

N/A

1x
7537 721

Qty
Order No.

Adapter Set

N/A

1x
7201 963

Qty
Order No.

ffManifold Insulation (optional) must be installed prior to mounting boilers.


ffThe Multiple Boiler Low-Loss Distribution Manifolds above are not for use with any boiler
other than Vitodens 200-W, B2HA Series.
ffAll boiler manifolds must be shipped and installed with a properly sized low-loss header.
ffUse only the configurations above - do not mix different boiler sizes.
ffMay request package without neutralization tank and receive a $424 credit.
This trademark is registered with the U.S. Patent and Trademark Office.

Other Equipment / Options (not included in


Package Standard Equipment):
Venting
Insulation for boiler manifold
Insulation for low-loss header
Factory start-up

31

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W
Multiple Boiler Installations
Vitodens 200-W

B2HA 60

Total Input
Total Output
Total Package List Price

Number of Boilers in Each Package


2

B2HAB55 B2HAB56 B2HAB57 B2HAB58 B2HAB59 B2HAB60 B2HAB61 B2HAB62


424
388
17,816.

636
582
24,643.

848
776
32,687.

848
776
34,169.

1060
970
41,020.

1272
1164
47,649.

1484
1358
55,892.

1696 MBH
1552 MBH
63,936.

Total Package consists of the items listed below


Vitodens 200-W

B2HA 60

2x
3x
4x
4x
5x
6x
B2HAA91 B2HAA91 B2HAA91 B2HAA91 B2HAA91 B2HAA91

7x
8x Qty
7533 377 B2HAA91 Blr Model
Order No.

1x
7202 856 Applicable for all sizes

Vitotronic 300-K, MW2C


Cascade control for up to 8 boilers

Qty
Order No.

KMK BUS Communication Module


Required for each Viessmann
Boiler controlled by cascade
control

2x
7441 586

3x
7441 586

4x
7441 586

4x
7441 586

5x
7441 586

6x
7441 586

7x
8x Qty
7441 586 7441 586 Order No.

Circulation Pump
UPS 26-99FC 120/1/60

2x
7248 585

3x
7248 585

4x
7248 585

4x
7248 585

5x
7248 585

6x
7248 585

7x
8x Qty
7248 585 7248 585 Order No.

Neutralization System
To neutralize acidic condensate,
includes pellets
CSD-Conversion Kit

2x
7841 861

3x
7841 861

Manifold 1

1x
7537 703

1x
7537 704

Manifold 2

4x
7841 861

4x
7841 861

2x
7537 703

1x
7537 705
160/80

Fittings 1

2x
7535 929

5x
7841 861

6x
7841 861

7x
8x Qty
7841 861 7841 861 Order No.

1x
7537 703

2x
7537 704

2x
4x Qty
7537 703 7537 703 Order No.

1x
7537 704

N/A

Low Loss Header

Fittings 2

Qty
Order No.

1x
7441 823 Applicable for all sizes

1x
7537 706
200/120
3x
7535 929
1x
7535 930

4x
7535 929

N/A

1x
7537 707
250/150
5x
7535 929

6x
7535 929

2x
7535 930

N/A

1x
7537 708
300/200

Qty
Order No.
Qty
Order No.

7x
8x Qty
7535 929 7535 929 Order No.
3x
4x Qty
7535 930 7535 930 Order No.

1x
7535 931 Applicable for all sizes

Fittings 3

1x
7537 704

Qty
Order No.

Y-Piece

N/A

1x
7537 721

Qty
Order No.

Adapter Set

N/A

1x
7201 963

Qty
Order No.

ffManifold Insulation (optional) must be installed prior to mounting boilers.


ffThe Multiple Boiler Low-Loss Distribution Manifolds above are not for use with any
boiler other than Vitodens 200-W, B2HA Series.
ffAll boiler manifolds must be shipped and installed with a properly sized low-loss header.
ffUse only the configurations above - do not mix different boiler sizes.
ffMay request package without neutralization tank and receive a $424 credit.

32

Other Equipment / Options


(not included in Package Standard Equipment):
Venting
Insulation for boiler manifold
Insulation for low-loss header
Factory start-up

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W

Vitodens 200-W

B2HA 80

Total Input
Total Output
Total Package List Price

Number of Boilers in Each Package


2

B2HAB63 B2HAB64 B2HAB65 B2HAB66 B2HAB67 B2HAB68 B2HAB69 B2HAB70


570
520
20,676.

855
780
28,641.

1140
1040
38,241.

1140
1040
39,712.

1425
1300
47,876.

1710
1560
55,841.

1995
1820
65,219.

2280 MBH
2080 MBH
74,867.

Total Package consists of the items listed below


Vitodens 200-W

B2HA 80

2x
3x
4x
4x
5x
6x
7x
8x Qty
B2HAA92 B2HAA92 B2HAA92 B2HAA92 B2HAA92 B2HAA92 B2HAA92 B2HAA92 Blr Model
Order No.
1x
7202 856 Applicable for all sizes

Vitotronic 300-K, MW2C


Cascade control for up to 8 boilers

Qty
Order No.

KMK BUS Communication Module


Required for each Viessmann
Boiler controlled by cascade
control

2x
7441 586

3x
7441 586

4x
7441 586

4x
7441 586

5x
7441 586

6x
7441 586

7x
8x Qty
7441 586 7441 586 Order No.

Circulation Pump
UPS 26-99FC 120/1/60

2x
7248 585

3x
7248 585

4x
7248 585

4x
7248 585

5x
7248 585

6x
7248 585

7x
8x Qty
7248 585 7248 585 Order No.

Neutralization System
To neutralize acidic condensate,
includes pellets

1x
7441 823

CSD-Conversion Kit

2x
7841 861

3x
7841 861

Manifold 1

1x
7537 703

1x
7537 704

Manifold 2

Low Loss Header

Fittings 1

Fittings 2

4x
7841 861

4x
7841 861

2x
7537 703

N/A
1x
7537 706
200/120
2x
7535 929

3x
7535 929

1x
7535 930

5x
7841 861

6x
7841 861

7x
8x Qty
7841 861 7841 861 Order No.

1x
1x
7537 703 7537 704

2x
4x Qty
7537 703 7537 703 Order No.

1x
7537 704

1x
7537 704

1x
7537 707
250/150
4x
7535 929

N/A
1x
7537 708
300/200

5x
7535 929

6x
7535 929

2x
7535 930

N/A

Qty
Order No.

1x Qty
7537 709 Order No.
400/200
7x
8x Qty
7535 929 7535 929 Order No.
3x
4x Qty
7535 930 7535 930 Order No.

1x
7535 931 Applicable for all sizes

Fittings 3

Qty
Order No.

Applicable for all sizes

Qty
Order No.

Y-Piece

N/A

1x
7537 721

Qty
Order No.

Adapter Set

N/A

1x
7201 963

Qty
Order No.

ffManifold Insulation (optional) must be installed prior to mounting boilers.


ffThe Multiple Boiler Low-Loss Distribution Manifolds above are not for use with any
boiler other than Vitodens 200-W, B2HA Series.
ffAll boiler manifolds must be shipped and installed with a properly sized low-loss header.
ffUse only the configurations above - do not mix different boiler sizes.
ffMay request package without neutralization tank and receive a $424 credit.

This trademark is registered with the U.S. Patent and Trademark Office.

Other Equipment / Options


(not included in Package Standard Equipment):
Venting
Insulation for boiler manifold
Insulation for low-loss header
Factory start-up

33

Vitodens
200-W

Multiple Boiler Installations

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W

Multiple Boiler Installations

Number of Boilers in Each Package


2

Vitodens 200-W

B2HA 100

Total Input
Total Output
Total Package List Price

B2HAB71 B2HAB72 B2HAB73 B2HAB74 B2HAB75 B2HAB76 B2HAB77 B2HAB78


704
666
23,185.

1056
999
32,626.

1408
1332
43,458.

1408
1332
44,929.

1760
1665
54,148.

2112
1998
63,638.

2464
2331
74,673.

2816 MBH
2664 MBH
86,138.

Total Package consists of the items listed below


Vitodens 200-W

B2HA 100

2x
3x
4x
4x
5x
6x
7x
8x Qty
B2HAA93 B2HAA93 B2HAA93 B2HAA93 B2HAA93 B2HAA93 B2HAA93 B2HAA93 Blr Model
Order No.
1x
7202 856 Applicable for all sizes

Vitotronic 300-K, MW2C


Cascade control for up to 8 boilers

Qty
Order No.

KMK BUS Communication Module


Required for each Viessmann
Boiler controlled by cascade
control

2x
7441 586

3x
7441 586

4x
7441 586

4x
7441 586

5x
7441 586

6x
7441 586

7x
8x Qty
7441 586 7441 586 Order No.

Circulation Pump
UPS 26-99FC 120/1/60

2x
7248 585

3x
7248 585

4x
7248 585

4x
7248 585

5x
7248 585

6x
7248 585

7x
8x Qty
7248 585 7248 585 Order No.

Neutralization System
To neutralize acidic condensate,
includes pellets
CSD-Conversion Kit

2x
7841 861

3x
7841 861

Manifold 1

1x
7537 703

1x
7537 704

Manifold 2

4x
7841 861

4x
7841 861

2x
7537 703

1x
7537 706
200/120

1x
7537 707
250/150

Fittings 1

2x
7535 929

3x
7535 929

1x
7535 930

6x
7841 861

7x
8x Qty
7841 861 7841 861 Order No.

1x
7537 703

2x
7537 704

2x
4x Qty
7537 703 7537 703 Order No.

N/A

1x
7537 708
300/200
4x
7535 929

1x
7537 704

1x
7537 709
400/200
5x
7535 929

6x
7535 929

2x
7535 930

N/A

Qty
Order No.

1x Qty
7537 710 Order No.
450/250

7x
8x Qty
7535 929 7535 929 Order No.
3x
4x Qty
7535 930 7535 930 Order No.

1x
7535 931 Applicable for all sizes

Fittings 3

Qty
Order No.

5x
7841 861

1x
7537 704

N/A

Low Loss Header

Fittings 2

2x
7441 823

1x
7441 823

Qty
Order No.

Y-Piece

N/A

1x
7537 721

Qty
Order No.

Adapter Set

N/A

1x
7201 963

Qty
Order No.

ffManifold Insulation (optional) must be installed prior to mounting boilers.


ffThe Multiple Boiler Low-Loss Distribution Manifolds above are not for use with any
boiler other than Vitodens 200-W, B2HA Series.
ffAll boiler manifolds must be shipped and installed with a properly sized low-loss header.
ffUse only the configurations above - do not mix different boiler sizes.
ffMay request package without neutralization tank and receive a $424 credit.

34

Other Equipment / Options


(not included in Package Standard Equipment):
Venting
Insulation for boiler manifold
Insulation for low-loss header
Factory start-up

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W

Number of Boilers in Each Package


2

Vitodens 200-W

B2HA 112

Total Input
Total Output
Total Package List Price

B2HAB79 B2HAB80 B2HAB81 B2HAB82 B2HAB83 B2HAB84 B2HAB85

B2HAB86

798
750
25,174.

1197
1125
35,808.

1596
1500
47,435.

1596
1500
48,905.

1995
1875
59,389.

2394
2250
70,006.

2793
2625
82,464.

3192 MBH
3000 MBH
94,091.

Total Package consists of the items listed below


Vitodens 200-W

B2HA 112

2x
3x
4x
4x
5x
6x
B2HAA94 B2HAA94 B2HAA94 B2HAA94 B2HAA94 B2HAA94

Vitotronic 300-K, MW2C


Cascade control for up to 8 boilers

7x
7533 380

8x Qty
B2HAA94 Blr Model
Order No.
Qty
Order No.

1x
7202 856 Applicable for all sizes

KMK BUS Communication Module


Required for each Viessmann
Boiler controlled by cascade
control

2x
7441 586

3x
7441 586

4x
7441 586

4x
7441 586

5x
7441 586

6x
7441 586

7x
7441 586

8x Qty
7441 586 Order No.

Circulation Pump
UPS 26-150F 120/1/60

2x
7441 596

3x
7441 596

4x
7441 596

4x
7441 596

5x
7441 596

6x
7441 596

7x
7441 596

8x Qty
7441 596 Order No.

2x
7441 823

Qty
Order No.

Neutralization System
To neutralize acidic condensate,
includes pellets

1x
7441 823

CSD-Conversion Kit

2x
7841 861

3x
7841 861

Manifold 1

1x
7537 703

1x
7537 704

Manifold 2

4x
7841 861

2x
7537 703

N/A

Low Loss Header

1x
1x
7537 706 7537 707
200/120
250/150

Fittings 1

2x
7535 929

Fittings 2

4x
7841 861

3x
7535 929

1x
7535 930

5x
7841 861

6x
7841 861

7x
7841 861

8x Qty
7841 861 Order No.

1x
7537 703

2x
7537 704

2x
7537 703

4x Qty
7537 703 Order No.

1x
7537 704

N/A

1x
7537 704

1x
7537 708
300/200

1x
7537 709
400/200

4x
7535 929

5x
7535 929

6x
7535 929

2x
7535 930
1x
7535 931 Applicable for all sizes

Fittings 3

Y-Piece

N/A

Adapter Set

N/A

1x
7537 721
1x
7201 963

ffManifold Insulation (optional) must be installed prior to mounting boilers.


ffThe Multiple Boiler Low-Loss Distribution Manifolds above are not for use with any
boiler other than Vitodens 200-W, B2HA Series.
ffAll boiler manifolds must be shipped and installed with a properly sized low-loss header.
ffUse only the configurations above - do not mix different boiler sizes.
ffMay request package without neutralization tank and receive a $424 credit.
This trademark is registered with the U.S. Patent and Trademark Office.

N/A

Qty
Order No.

1x Qty
7537 710 Order No
450/250
7x
7535 929

8x Qty
7535 929 Order No.

3x
7535 930

4x Qty
7535 930 Order No.
Qty
Order No.
Qty
Order No.
Qty
Order No.

Other Equipment / Options


(not included in Package Standard Equipment):
Venting
Insulation for boiler manifold
Insulation for low-loss header
Factory start-up

35

Vitodens
200-W

Multiple Boiler Installations

VITODENS 200-W
Multiple Boiler Installations

Vitodens 200-W

Multiple Boiler Installations


Vitodens 200-W B2HA 150
Total Input
Total Output
Total Package List Price

Number of Boilers in Each Package


2

B2HAB87 B2HAB88 B2HAB89 B2HAB90 B2HAB91 B2HAB92 B2HAB93 B2HAB94


4240 MBH
3710
3180
2650
2120
2120
1590
1060
3960 MBH
3465
2970
2475
1980
1980
1485
990
75,291. 89,434. 104,158. 119,337.
45,107. 60,549. 61,578.
31,598.
Total Package consists of the items listed below

Vitodens 200-W

B2HA 150

2x
3x
4x
4x
5x
6x
7x
8x Qty
B2HAA95 B2HAA95 B2HAA95 B2HAA95 B2HAA95 B2HAA95 B2HAA95 B2HAA95 Blr Model
Order No.
1x
7202 856 Applicable for all sizes

Vitotronic 300-K, MW2C


Cascade control for up to 8 boilers

Qty
Order No.

KMK BUS Communication Module


Required for each Viessmann Boiler
controlled by cascade control

2x
7441 586

3x
7441 586

4x
7441 586

4x
7441 586

5x
7441 586

6x
7441 586

7x
8x Qty
7441 586 7441 586 Order No.

Circulation Pump
UPS 26-150F 120/1/60

2x
7441 596

3x
7441 596

4x
7441 596

4x
7441 596

5x
7441 596

6x
7441 596

7x
8x Qty
7441 596 7441 596 Order No.

1x
7441 823

Neutralization System
To neutralize acidic condensate,
includes pellets

2x
7441 823

Qty
Order No

CSD-Conversion Kit

2x
7841 861

3x
7841 861

4x
7841 861

4x
7841 861

5x
7841 861

6x
7841 861

7x
8x Qty
7841 861 7841 861 Order No.

Gas Pressure Switch

2x
7842 160

3x
7842 160

4x
7842 160

4x
7842 160

5x
7842 160

6x
7842 160

7x
8x Qty
7842 160 7842 160 Order No.

Manifold 1

1x
7537 703

1x
7537 704

1x
7537 703

2x
7537 704

2x
4x Qty
7537 703 7537 703 Order No.

1x
7537 704

N/A

Manifold 2

N/A

Low Loss Header

1x
7537 707
250/150

1x
7537 708
300/200

Fittings 1

2x
7535 929

3x
7535 929

Fittings 2

1x
7537 709
400/200
4x
7535 929

1x
7535 930

Y-Piece

5x
7535 929

1x
7201 963

ffManifold Insulation (optional) must be installed prior to mounting boilers.


ffThe Multiple Boiler Low-Loss Distribution Manifolds above are not for use with any
boiler other than Vitodens 200-W, B2HA Series.
ffAll boiler manifolds must be shipped and installed with a properly sized low-loss header.
ffUse only the configurations above - do not mix different boiler sizes.
ffMay request package without neutralization tank and receive a $424 credit.

36

6x
7535 929

2x
7535 930

N/A

N/A

1x
7537 704

1x
7537 710
450/250

N/A

Qty
Order No.

1x Qty
7537 711 Order No.
500/300

7x
8x Qty
7535 929 7535 929 Order No.
3x
4x Qty
7535 930 7535 930 Order No.

1x
7535 931 Applicable for all sizes

Fittings 3

Adapter Set

2x
7537 703

Qty
Order No.

1x
7537 721

Qty
Order No.

N/A

Qty
Order No.

Other Equipment / Options


(not included in Package Standard Equipment):
Venting
Insulation for boiler manifold
Insulation for low-loss header
Factory start-up

VITODENS 200-W
Multiple Boiler Installations
System Components (If Rack Ordered Separately)
Vitodens 200-W

Number of Boilers in Each Package


3

B2HA 45

B2HAB05
11,564.-

B2HAB06
16,434.-

B2HAB07
21,304.-

B2HAB08
26,173.-

B2HAB09
31,043.-

B2HAB10
35,913.-

B2HAB11 Order No.


40,783.- US$

B2HA 60

B2HAB12
12,984.-

B2HAB13
18,706.-

B2HAB14
24,332.-

B2HAB15
29,959.-

B2HAB16
35,586.-

B2HAB17
41,213.-

B2HAB18 Order No.


46,840.- US$

B2HA 80

B2HAB19
15,756.-

B2HAB20
22,721.-

B2HAB21
29,687.-

B2HAB22
36,652.-

B2HAB23
43,617.-

B2HAB24
50,583.-

B2HAB25 Order No.


57,548.- US$

B2HA 100

B2HAB26
18,264.-

B2HAB27
26,483.-

B2HAB28
34,703.-

B2HAB29
42,922.-

B2HAB30
51,141.-

B2HAB31
59,361.-

B2HAB32 Order No.


67,580.- US$

B2HA 112

B2HAB33
20,253.-

B2HAB34
29,467.-

B2HAB35
38,681.-

B2HAB36
47,895.-

B2HAB37
57,109.-

B2HAB38
66,323.-

B2HAB39 Order No.


75,537.- US$

B2HA 150

B2HAB40
26,033.-

B2HAB41
38,137.-

B2HAB42
50,241.-

B2HAB43
62,345.-

B2HAB44
74,449.-

B2HAB45
86,553.-

B2HAB46 Order No.


98,657.- US$

Standard Equipment:
Vitodens 200 wall-mount boilers
Installation fittings with 30 psig pressure relief valve
Double Pipe Adaptors
Outdoor temperature sensor
DHW sensor
LLH sensor
fill/drain valves
mounting hardware
Gas Pressure Switch (for B2HA 112 and B2HA 150)
Vitotronic 300-K MW2C cascade control
KMK- BUS communication module

This trademark is registered with the U.S. Patent and Trademark Office.

37

Vitodens
200-W

VITODENS 200-W
Multiple Boiler Installations
System Components (If Rack Ordered Separately)
Wall-Mounted Master Boiler Control

Vitotronic 300-K, MW2C Series Color touch screen


wall-mounted, digital indoor/outdoor master boiler and heating system control
for up to 8 Vitodens 200-W boilers
with domestic hot water production features, including sensor
including strap-on supply temperature sensor
for low-loss header (NTC 10 kOhm)
capable of communication with Vitodens 200-W via KM-BUS protocol
capable of communication with Vitotronic 200-H via LON-BUS if equipped
with LON Communication Module (optional)
With electric circuit board for the 2. and 3. heating circuit with mixing valve

7202 856 Order No.


1913. US$

Communication
KMK Communication Module
electronic circuit board enabling data communication via Viessmann KMK
system BUS between Vitotronic 300-K and Vitodens 200-W.
For installation inside Vitodens 200-W.
Order one unit per Vitodens 200-W.

7441 586 Order No.


135. US$

LON Communication Module


electronic circuit board enabling data communication via Viessmann LON
system BUS. For installation inside Vitotronic 300-K, MW2B.

7172 174 Order No.


308. US$

LON Connecting Cable, 23ft / 7m


for data exchange between controls

7143 495 Order No.


52. US$

LON Extension Jack


to extend LON Connecting Cable

7143 496 Order No.


34. US$

LON Connecting Terminal (RJ, 2 Pieces)


to connect to field cabling via wall-mount boxes

7171 784 Order No.


76. US$

LON Terminal Resistor (2 Pieces)


to terminate the system BUS, a resistor must be installed on each free end

7143 497 Order No.


14. US$

KM-BUS Expansion Module


to connect between 2 and 9 additional devices to the KM-BUS

7133 393 Order No.


108. US$

Extension Module
wall-mounted extension module controls up to 2 circulation pumps
*boiler set point temperature
1 Analog input (0-10V)
3 Digital Inputs
1 Output contact (potential-free)
Refer to manual for additional info

7533 426 Order No.


348. US$

Extension Module AM1


wall-mounted extension module controls up to 2 circulation pumps

7533 425 Order No.


334. US$

Solar Module SM1


wall-mounted extension module with electronic differential control for
use with solar collectors when used with Vitodens boilers.
heating output balancing and diagnostic system
operation and display via boiler control
management of two tank systems from one collector field
second electronic differential control
thermostat function for supplemental heating or use of surplus heat
variable speed pump controller for solar circuit pump via pulse-width
control, or for solar circuit pump with PWM-input (mfg Grundfos)
includes one tank sensor and one collector sensor
120V, 60Hz, 2A in CSA housing, with 6.5 cord and 120V plug
To be used instead of an SCU Solar Controller

7533 427 Order No.


466. US$

38

VITODENS 200-W
Multiple Boiler Installations

Circulation Pump (Use with B2HA multiple boiler packages B2HA785-B2HA800


UPS26-99FC
120/1/60

7248 585 Order No.


391. US$

Circulation Pump (Use with B2HA multiple boiler packages B2HA785-B2HA800


UPS26-150FC
120/1/60

7441 596 Order No.


611. US$

Multiple Boiler Low-Loss Distribution Manifold


Accessories
7537 723 Order No.
727. US$

Connection Set
to install a field supplied 90 elbow set
4 x 4 ANSI flanges
with welded on 4 NPT coupling

Insulation
7537 712
2-boiler
668.

Manifold Insulation

7537 713 Order No.


3-boiler
1,125. US$

Low-Loss Header Insulation

For use with

7537705
160/80

7537706
200/120

7537707
250/150

7537708
300/200

7537709
400/200

7537710
450/250

7537 714
435.

7537 715
559.

7537 716
639.

7537 717
727.

7537 718
788.

7537 719
950.

Y-Piece Insulation

7537711
500/300
7537 720 Order No.
1,089 US$
7537 722 Order No.
328. US$

Hydronic Accessories
Viessmann Mixing Valves
Viessmann Mixing Valve Motor, 120/1/60
for Viessmann 3- and 4-way mixing valves only
order one mixing valve per low-temperature heating circuit
including strap-on supply temperature sensor (NTC 10 kOhm)
Maximum 2 Mixing Valves per single- or multiple-boiler application

7509 472 Order No.


225. US$

Power Supply Adaptor


required for each Viessmann mixing valve motor
120/1/60

7134 560 Order No.


174. US$

This trademark is registered with the U.S. Patent and Trademark Office.

39

Vitodens
200-W

Circulation Pumps

VITODENS 200-W
Multiple Boiler Installations

Hydronic Accessories

Viessmann 3-Way Mixing Valves

7134 742
308.

1
7134 743
328.

1
7134 744
368.

1
7134 745
413.

2
7134 746
506.

Dia
Order No.
US$

Danfoss 3-Way Mixing Valves


including flange set
includes actuator

2
ZK01698
1,001.

3
ZK01699
1,143.

4
ZK01700
1,506.

5
ZK01701
1,623.

6
ZK01702
2,056.

Dia
Order No.
US$

Neutralization
Neutralization System
to neutralize acidic condensate
includes pellets

7441 823 Order No.


424. US$

Sensors
Room Temperature Sensor (wall mount, NTC 10 kOhm)
for use with Vitotrol 300A
Order Room Temperature Sensor if Vitotrol 300A cannot be installed in a
centralized location to measure room temperature.

7438 537 Order No.


108. US$

Remote Controls
Vitotrol 200A
(KM-BUS protocol)
User interface to operate one heating circuit:
daytime temperature and operating program
with party and energy-saving button
display indication of outside temperature, room temperature and
operational settings
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)

7438 363 Order No.


162. US$

If the Vitotrol 200A is to operate based upon room-dependent activation,


ensure placement in a centralized location.
Vitotrol 300A
(KM-BUS protocol)
User interface to operate one, two or three heating circuits:
daytime temperature, set-back temperature, DHW temperature, operating
and holiday program, as well as party and energy-saving function
timer program for heating circuits, DHW production, and DHW recirculation
pump
illuminated graphic display to show outdoor temperature, room
temperature, operational settings together with descriptive texts
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)
If the Vitotrol 300A is to operate based upon room-dependent activation,
ensure placement in a centralized location.
Order Room Temperature Sensor 7438537 if the Vitotrol 300 cannot be installed
in a centralized location.

40

7172 619 Order No.


272. US$

Boiler/Tank Packages

Vitodens 200-W

Vitodens 200-W
with Vitocell tanks
B2HA/B2HB Series
Wall-Mounted Condensing Boiler
with modulating MatriX-cylinder burner
for room air dependent operation
or room air independent operation
Heating input: 12 to 530 MBH

3.5 to 155 kW
For natural gas or liquid propane gas

Vitocell 100

Vitocell 300

Vitocell 100
CVA Series
CVB Series
Indirect-fired domestic hot water storage tank
steel construction, with Ceraprotect two-coat enamel finish

Vitocell 300
EVI Series
EVB Series
Indirect-fired domestic hot water storage tank
of high grade stainless steel

This trademark is registered with the U.S. Patent and Trademark Office.

41

Boiler/Tank Packages

Single Vitodens 200


with Vitocell 300-V packages

Package No

Boiler

Boiler Qty

Tank

Tank Qty

Price

B2HB010

Vitodens 200, B2HB-19

Vitocell 300, EVI- 53

5,679.

US$

B2HB011

Vitodens 200, B2HB-26

Vitocell 300, EVI- 53

5,858.

US$

B2HB012

Vitodens 200, B2HB-35

Vitocell 300, EVI- 53

6,065.

US$

B2HAC78

Vitodens 200, B2HA-45

Vitocell 300, EVI- 79

7,396.

US$

B2HAC79

Vitodens 200, B2HA-60

Vitocell 300, EVI- 79

8,153.

US$

B2HAC80

Vitodens 200, B2HA-80

Vitocell 300, EVI- 79

9,491.

US$

B2HAC81

Vitodens 200, B2HA-45

Vitocell 300, EVB- 79

8,183.

US$

B2HAC82

Vitodens 200, B2HA-60

Vitocell 300, EVB- 79

8,940.

US$

B2HAC83

Vitodens 200, B2HA-80

Vitocell 300, EVB- 79

10,279.

US$

B2HAC84

Vitodens 200, B2HA-80

Vitocell 300, EVI- 119

11,176.

US$

B2HAC85

Vitodens 200, B2HA-100

Vitocell 300, EVI- 119

12,483.

US$

B2HAC86

Vitodens 200, B2HA-112

Vitocell 300, EVI- 119

13,159.

US$

B2HAC87

Vitodens 200, B2HA-80

Vitocell 300, EVB- 119

11,194.

US$

B2HAC88

Vitodens 200, B2HA-100

Vitocell 300, EVB- 119

12,448.

US$

B2HAC89

Vitodens 200, B2HA-112

Vitocell 300, EVB- 119

13,443.

US$

B2HAC90

Vitodens 200, B2HA-112

Vitocell 300, EVI- 79

14,387.

US$

B2HAC91

Vitodens 200, B2HA-112

Vitocell 300, EVI- 119

17,385.

US$

B2HAC92

Vitodens 200, B2HA-112

Vitocell 300, EVB- 79

15,962.

US$

B2HAC93

Vitodens 200, B2HA-112

Vitocell 300, EVB- 119

17,792.

US$

B2HAC94

Vitodens 200, B2HA-150

Vitocell 300, EVI- 79

17,277.

US$

B2HAC95

Vitodens 200, B2HA-150

Vitocell 300, EVI- 119

20,366.

US$

B2HAC96

Vitodens 200, B2HA-150

Vitocell 300, EVB- 79

18,852.

US$

B2HAC97

Vitodens 200, B2HA-150

Vitocell 300, EVB- 119

20,682.

US$

42

Boiler/Tank Packages

Single Vitodens 200


with Vitocell 100-V packages

Package No

Boiler

Boiler Qty

Tank

Tank Qty

Price

B2HB013

Vitodens 200, B2HB-19

Vitocell 100, CVA-42

4,718.

US$

B2HB014

Vitodens 200, B2HB-26

Vitocell 100, CVA-42

4,896.

US$

B2HB015

Vitodens 200, B2HB-35

Vitocell 100, CVA-42

5,103.

US$

B2HB016

Vitodens 200, B2HB-19

Vitocell 100, CVA-53

5,110.

US$

B2HB017

Vitodens 200, B2HB-26

Vitocell 100, CVA-53

5,289.

US$

B2HB018

Vitodens 200, B2HB-35

Vitocell 100, CVA-53

5,496.

US$

B2HAD04

Vitodens 200, B2HA-45

Vitocell 100, CVA-79

6,602.

US$

B2HAD05

Vitodens 200, B2HA-60

Vitocell 100, CVA-79

7,359.

US$

B2HAD06

Vitodens 200, B2HA-80

Vitocell 100, CVA-79

8,697.

US$

B2HAD07

Vitodens 200, B2HA-45

Vitocell 100, CVB-79

7,005.

US$

B2HAD08

Vitodens 200, B2HA-60

Vitocell 100, CVB-79

7,762.

US$

B2HAD09

Vitodens 200, B2HA-80

Vitocell 100, CVB-79

9,101.

US$

B2HAD10

Vitodens 200, B2HA-80

Vitocell 100, CVA-119

9,073.

US$

B2HAD11

Vitodens 200, B2HA-100

Vitocell 100, CVA-119

10,327.

US$

B2HAD12

Vitodens 200, B2HA-112

Vitocell 100, CVA-119

11,321.

US$

B2HAD13

Vitodens 200, B2HA-80

Vitocell 100, CVB-119

10,104.

US$

B2HAD14

Vitodens 200, B2HA-100

Vitocell 100, CVB-119

11,358.

US$

B2HAD15

Vitodens 200, B2HA-112

Vitocell 100, CVB-119

12,353.

US$

B2HAD16

Vitodens 200, B2HA-112

Vitocell 100, CVA-79

12,798.

US$

B2HAD17

Vitodens 200, B2HA-112

Vitocell 100, CVA-119

13,549.

US$

B2HAD18

Vitodens 200, B2HA-112

Vitocell 100, CVB-79

13,606.

US$

B2HAD19

Vitodens 200, B2HA-112

Vitocell 100, CVB-119

15,612.

US$

B2HAD20

Vitodens 200, B2HA-150

Vitocell 100, CVA-79

15,688.

US$

B2HAD21

Vitodens 200, B2HA-150

Vitocell 100, CVA-119

16,439.

US$

B2HAD22

Vitodens 200, B2HA-150

Vitocell 100, CVB-79

16,496.

US$

B2HAD23

Vitodens 200, B2HA-150

Vitocell 100, CVB-119

18,502.

US$

This trademark is registered with the U.S. Patent and Trademark Office.

43

NOTES

44

VITODENS 222-F

Vitodens
222-F

Gas-fired, floor-standing, condensing DHW combi-boiler


12 to125 MBH / 3.5 to 35 kW

Vitodens 222-F

Low cycle frequency, even with low heat demand, through optimized
pauses and wider modulation range of up to 1:6.5.

B2TB Series

Durable and efficient thanks to the Inox-Radial heat exchanger.

Gas-Fired Floor-Standing
Condensing DHW Combi-Boiler
with modulating MatriX-cylinder burner
and DHW stainless steel tank
for room air dependent operation
or room air independent operation
Heating input: 12 to 125MBH
3.5 to 35kW

MatriX gas burner with long service life thanks to stainless steel
MatriX gauze resistant to high temperature loads.
Energy-saving, high efficiency circulation pump (DHW tank).
Lambda Pro Control combustion controller for all gas types saves
on costs through an extension of the inspection interval to 3 years.
Universal connection sets for individual installation flush with the
wall.

For natural gas or liquid propane gas

This trademark is registered with the U.S. Patent and Trademark Office.

45

VITODENS 222-F

Vitodens 222-F
B2TB
19

B2TB
35

Model
No.

for Single
Boiler Installations only
Each Vitodens 222-F must
be sold and shipped with a
Connection Set

Vitodens 222-F
with Vitotronic 200 HO1B

B2TB003 B2TB004 Order No.


5,337.
5,646. US$

7201 537
328.

Order No.
US$

7201 538
328.

Order No.
US$

Connection Set
for left/right connection

Connection Set
for top connection

Input Range
Output Range
Total List Price

12-68
3.5-20

19-125 MBH
5.5-37 kW

10.9-64
3.2-19

17.4-117 MBH
5.1-34 kW

5,665.

5,974. US$

Technical Data
Dimensions
Length
Width
Height
Boiler Vent Connection
flue gas / fresh air

23
595
235/8
600
64
1625

23
595
235/8
600
64
1625

inches
mm
inches
mm
inches
mm

60/100

60/100 mm

Boiler Pressure Relief Valve

30

30 psig

DHW Pressure Relief Valve

150

150 psig

DHW Storage Tank

26
100

26 USG
100 ltr

Shipping Weight (incl. fittings)


not including vent system

311
141

311 lbs
141 kg

ffBoiler standard working pressure: 30 psig;


For 45 psig, order optional PRV 9549 944, List Price $35..
ffBoiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s), stainless steel or CPVC.
Standard Equipment:
Wall-mount boiler with integrated 26 USG / 100 ltr DHW tank,
Vitotronic 200 HO1B, Connection Set, and installation fittings.

46

VITODENS 222-F
Controls and Accessories

Accessories

LON Connecting Cable, 23ft / 7m


for data exchange between controls

7143 495 Order No.


52. US$

LON Extension Jack


to extend LON Connecting Cable

7143 496 Order No.


34. US$

LON Connecting Terminal (RJ, 2 Pieces)


to connect to field cabling via wall-mount boxes

7171 784 Order No.


76. US$

LON Terminal Resistor (2 Pieces)


to terminate the system BUS, a resistor must be installed on each free end

7143 497 Order No.


14. US$

LON Communication Module


electronic circuit board enabling data communication via Viessmann LON
system BUS. For installation inside Vitodens 200-W.

7179 113 Order No.


328. US$

Expanded Functions
Extension Module AM1
wall-mounted extension module controls up to 2 of the following circulation
pumps:
DHW recirculation pump
DHW production pump
heating circuit pump for the circuit without a mixing valve
120V, 60Hz, 4A in CSA housing, with 6.5 / 2m cord and 120V plug
1

7533 425 Order No.


334. US$

Each boiler must be equipped with 1 x 7179 113 LON Communication Module

This trademark is registered with the U.S. Patent and Trademark Office.

47

Vitodens
222-F

Communication

VITODENS 222-F

Accessories
B2TB
19

B2TB Model
35 No.

Heating Circuit
80/60

Low-Loss Header
with Insulation
to decouple
Max. Flow
high flow rate
systems from
the boiler loop

LLH Temperature Sensor


(Immersion, NTC) to measure
the temperature inside a low-loss
header

19.5 USGPM
4.4 m3/hr

standard equipment

7498 529
290.

Order No.
US$

7179 488
121.

Order No.
US$

Low-Temperature Heating Circuits


Mixing Valve Extension Kit consisting of:

ZK01105 Order No.


644. US$

Mixing Valve Module (KM-BUS participant, wall mount)


plugs for circulation pump and mixing valve motor
KM-BUS
120V, 60Hz, 2A in CSA housing, with 6.5 / 2m cord and 120V plug
Mixing Valve Motor, 120/1/60
for Viessmann 3- and 4-way mixing valves only
including strap-on supply temperature sensor (NTC 10 kOhm)
Maximum 2 Mixing Valve Extensions per Vitodens boiler in single boiler
applications

Viessmann 3-Way Mixing Valves

7134 742
308.

1
7134 743
328.

1
7134 744
368.

1
7134 745
413.

2
7134 746
506.

Order No.
US$

Neutralization
Neutralization System
to neutralize acidic condensate
includes pellets
Neutralization Granulate

48

7134 231
368.

Order No.
US$

9524 670
5.7 lbs / 2.6 kg
76.

Order No.
US$

VITODENS 222-F
Accessories

Accessories

Remote Controls
7438 363 Order No.
162. US$

Vitodens
222-F

Vitotrol 200A
(KM-BUS protocol)
User interface to operate one heating circuit:
daytime temperature and operating program
with party and energy-saving button
display indication of outside temperature, room temperature and
operational settings
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)
If the Vitotrol 200A is to operate based upon room-dependent activation,
ensure placement in a centralized location.
Maximum 2 Vitotrols per Vitotronic.
Vitotrol 300A
(KM-BUS protocol)
User interface to operate one, two or three heating circuits:
daytime temperature, set-back temperature, DHW temperature, operating
and holiday program, as well as party and energy-saving function
timer program for heating circuits, DHW production, and DHW recirculation
pump
illuminated graphic display to show outdoor temperature, room
temperature, operational settings together with descriptive texts
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)

7172 619 Order No.


272. US$

Maximum 2 Vitotrols per Vitotronic.


Room Temperature Sensor (wall mount, NTC 10 kOhm)
for use with Vitotrol 300A

7438 537 Order No.


108. US$

Order room temperature sensor if Vitrol 300A cannot be installed in a centralized location
to measure room temperature.

Other
Wall-Mount Base
to reposition the programming unit outside of the Vitotronic
mounting base
blind cover
connection cable

7299 408 Order No.


108. US$

KM-BUS Distributor
to connect between 2 and 9 additional devices to the KM-BUS

7133 393 Order No.


108. US$

OT/KM-Bus Module
to convert the Viessmann KM-Bus signal to OpenThermTM
120V, 60Hz in CSA housing, with 6.5 / 2m cord and 120V plug
Order 1 unit per boiler.

7533 428 Order No.


414. US$

Service
Service Tool Set
for Vitodens boilers

This trademark is registered with the U.S. Patent and Trademark Office.

9537 070 Order No.


Net Price
121. US$

49

VITODENS 222-F
Coaxial PP(s) Vent System

Vent System Diameter

Vent System 1

60/100
Maximum Equivalent
Length (EqL)

Horizontally Vented

B2TB

Boiler Vent Pipe Adaptor


Room Air
Independent Operation
Important!
As a starting point,
please pay attention to
boiler vent connection size
shown above

Basic Horizontal Vent Kit


Venting pieces can be ordered
individually, or as a convenient
kit using the Order No. to the
right; Basic Vent Kit includes one
of each of the items numbered
to and two mounting clips .

80/125

19/35
33 / 10
ft/m

100/150

19/35
40 / 12
ft/m

Diameter

19/35
50 / 15
ft/m

included with boiler

7424 120
460.

7424 121
817.

Order
No.
US$

7424 115
87.

Order
No.
US$

7424 112
100.

OrderNo.
US$

7424 113
162.

Order
No.
US$

7424 114
121.

Order
No.
US$

7424 119
413.

Flue Transition
110/150 to 100/150 only
not shown - required B2TB 19/35

Adaptor, coaxial
60/100 to 80/125
not shown - only for B2TB 19/35

Adaptor, coaxial
60/100 to 100/150

not shown - only for B2TB 19/35

Adaptor, coaxial
80/125 to 100/150

not shown - only for B2TB 19/35

90 Elbow
EqL = 1.6ft. / 0.5m
Straight Pipe2
3.3ft. / 1m
Vent Termination
2.6ft. / 0.8m

7424 094
67.

7424 095
100.

7424 096
144.

Order
No.
US$

7424 091
76.

7424 092
100.

7424 093
121.

Order
No.
US$

7424 100
144.

7424 101
162.

7424 102
174.

Order
No.
US$

Protective Screen1

A Combustion Air Intake


B Flue Gas Outlet

Mounting Clip2
(each)

ft. / m

Order
No.
US$

7160 616
77.

7424 109
16.10

7424 110
20.

7424 111
26.

Order
No.
US$

PP(s) coaxial vent material must be ULC S-636 certified for Category IV boilers. Do not mix non-ULC S-636 with ULC S-636 venting.
Side wall venting installation must include Viessmann Protective Screen!
2
Order 1 Mounting Clip for each straight length of vent pipe installed.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.
1

50

VITODENS 222-F
Coaxial PP(s) Vent System

Vent System Diameter


60/100
Maximum Equivalent
Length (EqL)

Vertically Vented

B2TB

Boiler Vent Pipe Adaptor

Room Air
Independent Operation
Important!
As a starting point, please pay
attention to boiler vent
connection size shown on
page 46

19/35
33 / 10
ft/m

80/125

100/150

19/35
40 / 12
ft/m

19/35
50 / 15
ft/m

Diameter
ft. / m

included with boiler


7424 115 Order No.
87. US$

7424 112
100.

7424 113 Order No.


162. US$

7424 114 Order No.


121. US$

90 elbow
EqL 1.6 ft/0.5 m

7424 094
67.

7424 095
100.

7424 096 Order No.


144. US$

Mounting Clip 2 (each)

7424 109
16.10

7424 110
20.

7424 111 Order No.


26. US$

Sliding Coupling
1.25ft. / 0.4m

7424 106
67.

7424 107
76.

7424 108 Order No.


87. US$

Straight Pipe 2
1.6ft. / 0.5m
Straight Pipe 2
3.3ft. / 1m

7424 088
52.
or
7424 091
76.

7424 089
67.
or
7424 092
100.

7424 090
100.
or
7424 093
121.

45 Elbow (Set of 2)
EqL = 1.0ft. / 0.3m

7424 097
121.

7424 098
135.

7424 099 Order No.


191. US$

Vent Termination
3.9ft. / 1.2m

7424 103
256.

7424 104
350.

7424 105 Order No.


435. US$

Flue Transition
110/150 to 100/150 only

not shown - required B2TB 19/35

Adaptor, coaxial
60/100 to 80/125

Order No.
US$

not shown - only for B2TB 19/35

Adaptor, coaxial
60/100 to 100/150
not shown - only for B2TB 19/35

Adaptor, coaxial
80/125 to 100/150

not shown - only for B2TB 19/35

Roof Flashing
and Storm Collar
(B-Vent material or better)

Order No.
US$
Order No.
US$

field
supplied

A Combustion Air Intake


B Flue Gas Outlet

PP(s) coaxial vent material must be ULC S-636 certified for Category IV boilers. Do not mix non-ULC S-636 with ULC S-636 venting.
Order 1 Mounting Clip for each straight length of vent pipe installed.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.

1
2

This trademark is registered with the U.S. Patent and Trademark Office.

51

Vitodens
222-F

Vent System 1

VITODENS 222-F
Alternative Vent Systems

Alternative Vent Systems

Boiler Flue Gas Connection


60
Coaxial Venting 1 see pages 50 and 51

80

60/100

100

80/125

Diameter

100/150

direct-connect venting
- no special adaptors required
Protective Screen
(for side wall installations only)
Rigid and Flexible PP(s) Venting 1




for Combustion Air Intake 4


(only if installing ABS, CPVC or
PVC piping for combustion air
intake, please order one CPVC
Adaptor per boiler)

Adaptor, CPVC
60mm to 2

for Combustion Air Intake 4 and


for Flue Gas Outlet

for Flue Gas Outlet

100

Diameter

7134 769
7.90

7134 769
7.90

7134 769 Order No.


7.90 US$

field
supplied

field Order No.


supplied US$

2x
7134 769
7.90

2x
7134 769
7.90

2x
7134 769
7.90

Qty
Order No.
US$

field
supplied

field
supplied

Order No.
US$

Adaptor, CPVC
60mm to 2

7134 769
7.90

7134 769
7.90

Order No.
US$

Adaptor
2 to 3 or 3 to 4

field
supplied

field
supplied

Order No.
US$

PP(s) Adaptor
for stainless steel
60mm to 80mm required

field
supplied

field
supplied

Order No.
US$

Adaptor, CPVC
60mm to 2

Stainless Steel Venting 3


for Combustion Air Intake 4

80

Adaptor
2 to 3 or 3 to 4

Order No.
US$

60

Adaptor
2 to 3 or 3 to 4

CPVC Venting 2

7160 616
77.

Diameter

Diameter

Coaxial and PP(s) vent material must be ULC S-636 certified for Category IV boilers. Suggested source: Centrotherm, or M&G Duravent.
CPVC vent material must be ULC/UL listed for Category IV boilers. Suggested source: IPEX Inc.
3
Stainless steel vent material must be ULC/UL listed for Category IV boilers.
Suggested sources: Flexmaster Canada Ltd. / Z-Flex (US) Inc., Heat-fab, M&G Duravent, or Security Chimneys International.
4
Combustion air supply pipe may be made of the following materials: PP(s), ABS, CPVC, or PVC.
ffAlways follow the installation instructions of the vent manufacturer and of Viessmann.
1
2

52

VITOCROSSAL 200

Vitorcrossal
200

High efficiency, gas-fired condensing boiler


133 to 2245 MBH / 39 to 658 kW

Vitocrossal 200
CM2 Series
High efficiency, gas-fired condensing boiler
with Inox-Crossal heat exchanger surfaces
of corrosion-resistant stainless steel
and modulating pre-mix cylinder burner
Heating input: 133 to 2245 MBH

39 to 658 kW

This trademark is registered with the U.S. Patent and Trademark Office.

Inox-Crossal heat exchanger surface made of high grade SA240-316 Ti


stainless steel for high operational reliability and long service life.
- Easy dispersal of condensate through vertical gas flues; therefore no
concentration of condensate.
- Increased self-cleaning effect through smooth stainless steel surfaces.
Highly efficient heat transfer and high condensation rate through
- heat exchanger surfaces which intensely turbulate the flue gas flow
- boiler water and hot gases flowing in counterflow.
The flue gas temperature is only approximately 9 - 27F / 5 - 15C above
boiler return temperature.
Clean combustion - through perfect match of burner and boiler, low
combustion chamber loading and straight-through combustion chamber.
Easy handling in boiler rooms through particularly low build height and
weight.
No dedicated boiler pump required due to extremely low pressure drop
through heat exchanger.

53

VITOCROSSAL 200 (NOTE: Please refer to the CM2 supplement until the first quarter of 2015)

CM2 186

CM2 246

CM2 311

CM2 400

CM2 500

CM2 620TX

CM2 620

Model No.

Vitocrossal 200, CM2


CM20487

CM20488

CM20489

CM20490

CM20491

CM20493

CM20492

133-663
39-194

175-878
51-257

222-1112
65-326

281-1445
82-423

351-1800
103-527

436-1999
128-585

436-2245 MBH
128-658 kW

623
183

826
242

1052
308

1372
402

1710
501

1899
556

2132 MBH
625 kW

18,315.-

22,030.-

31,379.-

35,483.-

40,970.-

42,936.-

42,928.-

73
1852
361/2
930
66
1676

73
1852
361/2
930
66
1676

73
1852
361/2
930
66
1676

891/2
2273
423/8
1078
655/8
1666

955/8
1852
423/8
930
683/4
1676

1007/8
2562
443/8
1128
683/4
1748

1007/8
2562
443/8
1128
683/4
1748

Boiler Vent Connection

8
201

8
201

8
201

10
252

10
252

10
252

Shipping Weight (incl. fittings)


not including vent system

726
329

759
344

792
359

1495
678

1495
678

1929
875

with Vitotronic 300, GW6B

Input Range

Output Range

List Price

Model No.

US$

Technical Data
Dimensions
Length
Width
Height

inches
mm
inches
mm
inches
mm

10 inches
252 mm
1929 lbs
875 kg

For high altitude installations (5,000 to 10,000 ft), the input will have an altitude de-ration of 15% for 5 000 ft. and 18% for 10,000 ft.
When using a common vent system, order one vent damper per boiler; For CM2 186- 311, 7594 328 List Price $1084.-.
For CM2 400-620, 7594 321 List Price $1232.-.

ffBoiler standard working pressure: 75 psig.


For 30 psig, order optional pressure relief valve 9544 343, List Price $ 127..
ffBoiler is suitable for operation with a balanced flue. Please use a certified Category IV vent system of PP(s) or stainless steel.
Standard Equipment:
Floor-standing boiler
Insulation jacket 1 + 2
Cylinder burner (with LP conversion kit)
Air intake kit
Vitotronic
Electrical box
Installation fittings
Boiler is shipped assembled or disassembled.

54

VITOCROSSAL 200

Control Accessories

LON Connecting Cable, 23ft / 7m


for data exchange between controls

7143 495
52.

Order No.
US$

LON Extension Jack


to extend LON Connecting Cable

7143 496
34.

Order No.
US$

LON Connecting Terminal (RJ, 2 Pieces)


to connect to field cabling via wall-mount boxes

7171 784
76.

Order No.
US$

LON Terminal Resistor (2 Pieces)


to terminate the system BUS, a resistor must be installed on each free end

7143 497
14.

Order No.
US$

7559 706
1,380.

Order No.
US$

Vitogate 300 BN/MB Series


configured for integration inside Vitocrossal electrical box1

7559 705
1,310.

Order No.
US$

Output Module (potential-free contact) for burner status, burner failure,


high boiler temperature, and external (LWCO) alarm via LON. 3
(Order one per boiler; max.: 4)

7134 562
695.

Order No.
US$

Communication Module for data exchange with Vitotronic 200 HK1S / HK3S
(Order one per boiler; max.: 4)

7172 173
272.

Order No.
US$

Vitogate is a gateway designed to integrateVitotronic controlswhich utilize the


LON communication protocol with Building Management Systemsutilizing BACnet or
ModBUS communication modules.
Vitogate 300, BN/MB Series
configured as compact wall-mount unit
- dimensions:
W 6
H 6
D 6
- 120V, 60Hz, 1A, with 6.5 cord and 120Vpkg

Expanded Functions

Extension Module EA1


wall-mounted extension module whose inputs and outputs enable up to 5 additional functions:.
boiler setpoint temperature
1 Analog input (0 - 10 V).
3 Digital inputs.
1 Output contact (potential-free)
Refer to tech data manual for additional information

7533 426
348.

Order No.
US$

Extension Module AM1


wall-mounted extension module controls up to 2 circulation pumps

7533 425
334.

Order No.
US$

Combustion Air Device


* Fresh Air Device Kit to activate one single fresh air device.
(Order one unit per boiler, for use with Vitotronic 300 GW6B only)

ZK01905
529.

Order No.
US$

*Common Fresh Air Device Interface


if > 1 boiler utilize the common fresh air device.
(Order 1 unit for 2-4 boilers, order 2 units for 5-8 boilers)

7134 604
391.

Order No.
US$

Each boiler control must be equipped with 1 x 7172 173 LON Communication Module.

This trademark is registered with the U.S. Patent and Trademark Office.

55

Vitorcrossal
200

Communication

VITOCROSSAL 200
Accessories

Accessories
Low-Temperature Heating Circuits
Viessmann 3-way Mixing Valves
3-way mixing valves (NPT thread)

3/4
7134 742
308.

1
7134 743
328.

1
7134 744
368.

1
7134 745
413.

2
7134 746
506.

Viessmann 4-Way Mixing Valves

7134 736
328.

1
7134 737
350.

1
7134 738
391.

1
7134 739
435.

2
7133 018
534.

2
7133 019
668.

Diameter
Order No.
US$

Viessmann Mixing Valve Actuator 4


to control single heating circuit with one
mixing valve
including Viessmann #2 strap-on supply sensor
(Vitotronic 300, GW2 or Vitocontrol-S required;
order max. 2 units)

plus 7542 257


225.

Order No.
US$

Order 1 x 120VAC Power Supply Adaptor for each


Viessmann motor

plus 7534 277 for


221. Vitotronic 300

Order No.
US$

Viessmann Mixing Valve Motor, 120/1/60


for Viessmann 3- and 4-way mixing valves only
order one mixing valve per low-temperature heating circuit
including strap-on supply temperature sensor (NTC 10 kOhm)
4

Diameter
Order No.
US$

Maximum 2 Mixing Valves


per single- or multiple-boiler
application

7509 472
225.

Each mixing valve package includes 1 x 7183 288 Viessmann strap-on supply sensor #2. If mixing valves are field supplied
(or already installed in a preexisting application), please order 1 x 7183 288 for each mixing valve. List Price $108.-

56

Order No.
US$

VITOCROSSAL 200
Accessories

Accessories

Danfoss 3-way Mixing Valves 4


Includes:
*Danfoss Mixing valve
*Danfoss actuator
*Viesmann #2 sensor

2
ZK01698
1,001.

3
ZK01699
1,143.

4
ZK01700
1,506.

5
ZK01701
1,623.

6
ZK01702
2,056.

Dia
Order No.
US$

Includes:
*Danfoss Mixing valve
*Danfoss actuator
*Temperature Sensor NTC 10kOhm

2
ZK01713
1,028.

3
ZK01714
1,170.

4
ZK01715
1,533.

5
ZK01716
1,650.

6
ZK01717
2,083.

Order No.
US$

Power Supply Adaptor


required for each Danfoss mixing valve
for use with Vitotronic 300, GW6B
24/1/120

Order No.
US$

7134559
221.

System Components
Conbraco Motorized Isolation Valves
High quality motorized isolation valve
c/w mounting kit, flange set, and ball valve
Order 1 x 120VAC Power Supply Adaptor for each
motorized isolation valve

2
Z001 124
2,280.

2
Z001 125
3,878.

3
Z001 126
3,916.

4
Z001 199
4,583.

6
Z001 184
7,510.

Dia
Order No.
US$

plus 7534 277


221.

Order No.
US$

Neutralization

Neutralization System
to neutralize acidic condensate
includes 18 lbs / 8 kg neutralization pellets

7441 823
424.

Order No.
US$

Neutralization Pellets
18 lbs / 8 kg

9521 702
89.

Order No.
US$

Condensate Siphon
comes standard on all CM2s fits CM2 186 through 620

7824 743
22.

Order No.
US$

ANSI flanges, bolts, and gaskets are field supplied

This trademark is registered with the U.S. Patent and Trademark Office.

57

Vitorcrossal
200

Danfoss Mixing Valves

NOTES

58

VITOCELL 100-V VITOCELL 100-B

Vitocell
100-V, 100-B

Indirect-fired domestic hot water storage tank


42 to 119 USG / 160 to 450 ltr

Vitocell 100-V
up to 79 USG / 300 ltr capacity

Vitocell 100
CVA Series
CVB Series
Indirect-fired domestic hot water storage tank
steel construction, with Ceraprotect two-coat enamel finish

This trademark is registered with the U.S. Patent and Trademark Office.

Vitocell 100-V
119 USG / 450 ltr capacity

Corrosion-protected steel tank shell with Ceraprotect two-coat


enamel finish.
Magnesium anode provides additional tank protection.
Heat exchanger coil extends to the bottom of the tank, thereby
heating the entire water content.
Extremely reliable domestic hot water supply assured through
fast, uniform heating via generously sized heat exchanger
surfaces.
Standby losses minimized by highly effective 2"
foamed-in-place or 4" wrap-around HCFC-free insulation.
Universally suitable for applications requiring larger quantities
of hot water, multiple Vitocell-V 100 tanks may be connected to a
header to form a tank battery.
Vitocell 100-B, CVB Series for a dual-mode DHW heating with
solar panels in conjunction with a boiler.

59

VITOCELL 100-V

VITOCELL 100-B

Vitocell 100

steel, with two-coat


enamel finish

CVA-42

CVA-53

CVA-79

CVA-119

7134 160
1,197.

7134 161
1,610.

7134 162
1,950.

ZK00427
2,345.

CVB-79

CVB-119

Model
No.

DHW tank to heat water for


domestic use in combination with
a hot water heating boiler
CVA Series

Brass Elbow with sensor well for


tank temperature sensor
(for solar applications only)
Optional Equipment
not included in List Price

7175 213
35.

7175 214
35.

CVB Series

7134 448 ZK00428


2,375.
3,431.

included
above

Order No.
US$

included
above

Order No.
US$

7823 192 7823 193


62.
67.

Order No.
US$

7265 133
144.

Order No.
US$

7246 582
162.
Net Price

Order No.
US$

DHW Pump Module 1


Please see Page 65

Anode Protection
Rod Anode

7819 651
52.

Chain Anode
for tight service areas

7813 365
162.

7819 652
62.

7819 653
67.

7265 133
144.
7246 582
162.
Net Price

Tester
for consumable anodes

Important: to maintain tank warranty, consumable anode must be properly inspected and,
where necessary, replaced every two years.

Technical Data
Capacity

42
160

53
200

79
300

119
450

79
300

23
581
24
608
47
1189

23
581
24
608
55
1409

25
633
27
705
68
1746

33
850
35
898
77
1955

25
633
28
705
68
1746

190
86

214
97

333
151

399
181

352
160

WrapAround

PUR
Foam

Dimensions
Length
Width
Height

Weight

Insulation

PUR
Foam

119 USG
450 ltr
33
850
36
918
77
1955

inches
mm
inches
mm
inches
mm

452 lbs
205 kg
WrapAround

Optional equipment for Vitodens 100 and Vitorond 100 with hyrdolevel controls. Not needed for Vitodens 200 boilers, Vitotronic 100
KW10B, Vitotronic 200 KW2, or Vitotronic 300 KW3 controls.

Standard Equipment:
DHW tank c/w 150 psig temperature and pressure relief valve, and
installation fittings.

60

VITOCELL 300-H

Vitocell
300-H

Indirect-fired domestic hot water storage tank


42 to 119 USG / 160 to 450 ltr

Vitocell 300-H
EHA Series
Indirect-fired domestic hot water storage tank
of high grade stainless steel

Corrosion-resistant tank of high-grade SA 240 - 316 Ti stainless


steel offers a long service life.
Completely hygienic and lightweight.
Does not require a consumable anode for corrosion protection.
Heat exchanger coil extends to the tank bottom to heat the
complete tank volume, no cool zones - hygienic.
Extremely reliable domestic hot water supply assured through
fast, uniform heating via generously sized heat exchanger
surfaces.
Standby losses minimized by 2", highly effective,
foamed-in-place, HCFC-free insulation.
Approved by the State of Massachusetts as ASME Equivalent.

This trademark is registered with the U.S. Patent and Trademark Office.

61

VITOCELL 300-H

Vitocell 300-H
stainless steel

EHA-42

EHA-53

EHA-92

EHA-119

Model
No.

7134 401
2,431.

7134 402
3,066.

7134 403
4,026.

7134 404
4,890.

Order No.
US$

no

no

max. 2

max. 3

DHW tank to heat water for


domestic use in combination with
a hot water heating boiler 1

Stackable
Optional Equipment
not included in List Price

DHW Pump Module 2


Please see Page 65
Electronic Anode
Please see Page 65

Technical Data
Capacity

42
160

53
200

92
350

119
450

42
1072
25
640
25
654

48
1236
25
640
25
654

62
1590
32
830
31
786

65
1654
35
910
35
886

168
76

185
84

379
172

421
191

USG
ltr

Dimensions
Length
Width
Height

Weight

Insulation

inches
mm
inches
mm
inches
mm
lbs
kg

PUR Foam

Some Vitocell 300-H tanks can be installed as a tank battery.


Two 92 USG / 350 Ltr. tanks or three 119 USG / 450 Ltr. tanks may be stacked.
2
Optional equipment for Vitodens 100 and Vitorond 100 with hyrdolevel controls. Not needed for Vitodens 200 boilers, Vitotronic 100
KW10B, Vitotronic 200 KW2, or Vitotronic 300 KW3 controls.
1

Standard Equipment:
DHW tank c/w temperature and pressure relief valve
(USA 150 psig), and installation fittings.
Important!
For multiple tank applications, please see Technical Data Manual.

62

VITOCELL 300-V

VITOCELL 300-B

Vitocell
300-V, 300-B

Indirect-fired domestic hot water storage tank


53 to 119 USG / 200 to 450 ltr

Vitocell 300-V
up to 79 USG / 300 ltr capacity

Vitocell 300
EVI Series
EVB Series
Indirect-fired domestic hot water storage tank
of high grade stainless steel

This trademark is registered with the U.S. Patent and Trademark Office.

Vitocell 300-V
119 USG / 450 ltr capacity

Corrosion-resistant tank of high-grade SA 240 - 316 Ti stainless


steel offers a long service life.
Completely hygienic and lightweight.
Does not require a consumable anode for corrosion protection.
Heat exchanger coil extends to the tank bottom to heat the
complete tank volume, no cool zones - hygienic.
Extremely reliable domestic hot water supply assured through
fast, uniform heating via generously sized heat exchanger
surfaces.
Standby losses minimized by highly effective, 2"
foamed-in-place or 4" wrap-around HCFC-free insulation.
Vitocell-B 300, EVB Series for a dual-mode DHW heating with
solar panels in conjunction with a boiler.
Approved by the State of Massachusetts as ASME Equivalent

63

VITOCELL 300-V

VITOCELL 300-B

Vitocell 300
stainless steel

EVI-53

EVI-79

EVI-119

EVB-79

EVB-119

Model
No.

7134 381
2,209.

7134 382
2,786.

ZK00431
4,084.

7134 383
3,615.

ZK00432
4,578.

Order No.
US$

7219 729
35.

7175 213
35.

7219 729
35.

Order No.
US$

DHW tank to heat water for


domestic use in combination with
a hot water heating boiler
EVI Series

Brass Elbow with sensor well for


tank temperature sensor
(for solar applications only)
Optional Equipment
not included in List Price

7175 213
35.
DHW Pump Module 1
Please see Page 65
Electronic Anode1
Please see Page 65

Technical Data
Capacity

Dimensions
Length
Width
Height

Weight

Insulation

53
200

79
300

119
450

79
300

119
450

251/2
649
227/8
581
56
1420

273/4
704
25
633
70
1779

383/8
974
361/3
923
681/2
1740

28
704
25
633
70
1779

381/3
974
361/3
923
681/2
1740

168
76

220
100

245
111

251
114

275
125

Wraparound

PUR
Foam

Wraparound

PUR
Foam

USG
ltr

inches
mm
inches
mm
inches
mm
lbs
kg

Optional equipment for Vitodens 100 and Vitorond 100 with hyrdolevel controls. Not needed for Vitodens 200 boilers, Vitotronic 100
KW10B, Vitotronic 200 KW2, or Vitotronic 300 KW3 controls.
Engineered seismic bracket kits, which comply with local seismic requirements, are available from Viessmann.
For Vitocell 300-V EVI Series and EVB Series (119 USG / 450 ltr size only). order 7134 603, List Price $913..

Standard Equipment:
DHW tank (insulation preinstalled up to size 79 USG / 300 ltr)
c/w temperature and pressure relief valve
(USA 150 psig) and installation fittings.
Important!
For multiple tank applications, please see Technical Data Manual.

64

VITOCELL
Accessories

Vitocell 300

Optional Equipment
Electronic Anode
Must be installed by Viessmann at the factory. The anode must be ordered with the tank,
and is only available with new orders. Water quality is crucial to the longevity of
a domestic hot water storage tank.

7134 456
542.
Net Price

Order No.
US$

9543 430 7416 058


559.
538.

Order No.
US$

All domestic hot water storage tanks are sensitive to chloride concentration and
to the hardness of water. Water hardness is a function of the total dissolved
solids such as chloride, calcium, magnesium, sodium bicarbonate, nitrogen,
phosphorous, iron and sulphur in the water. The higher the water hardness
(measured in ppm), the higher its electrical conductivity (measured in S / cm).

Vitocell
300-V, 300-B

The US Environmental Protection Agency has established that the municipal


maximum drinking water chloride concentration shall be 250 ppm. A chloride
concentration of 25 ppm is considered normal.
If water conditions exceed the aforementioned values, the installation of an
electronic anode becomes necessary. In such circumstances, even a stainless
steel storage tank will ultimately fail without anode protection.
Viessmann requires the installation of an electronic anode in the following
circumstances:
In all cases where a product has failed before due to corrosive
water conditions.
In all Vitocell 300 multiple tank applications where water quality is an issue.
In all situations where water conditions are uncontrolled or not known
i.e. for well water.
If in doubt, contact Viessmann regarding water quality.
Features:
Suitable for Vitocell 300 only - EHA 350/450L, EVI 300/450L.
Each Vitocell 300 tank requires its own anode.
Electronic anodes must be inspected annually to verify proper operation.
For more technical information, please contact Viessmann.

DHW Pump Modules

for use with Vitocell DHW tanks

Control 1 for DHW production


DHW Pump Modules only operate with DHW production priority over space heating.
ffImportant: pumps must be field supplied.

Important!
Consult Viessmann for pricing on custom DHW Pump Modules for multiple tank, commercial, domestic hot water heating applications.
Important!
For commercial applications, Viessmann strongly recommends the installation of an additional safety high limit aquastat into the main
domestic hot water discharge header to be wired in series with the operating limit aquastat installed in the tank sensing well.
For residential applications, Viessmann strongly recommends the installation of a temperature tempering valve in the domestic hot
water supply line.

This trademark is registered with the U.S. Patent and Trademark Office.

65

NOTES

66

VITOTRONIC 200-H

Vitotronic
200-H

Digital indoor/outdoor heating circuit control

Vitotronic 200-H

Energy efficient heating via reduced supply temperature to


heating circuit.

HK1B Series

Universally applicable to both small and large heating systems.

Digital indoor/outdoor heating circuit control


easy to operate control with clear textual prompts and graphic
display for one heating circuit with mixing valve and management
of domestic hot water production.

Easy to operate control with clear textual prompts and graphic


display.
Includes:
- programmable time periods and temperature display
- automatic summer/winter switch over
- holiday program
Capable of communication via LON-BUS.

This trademark is registered with the U.S. Patent and Trademark Office.

67

VITOTRONIC 200-H
HK1B Series

Wall-Mounted Heating Circuit Control

Vitotronic 200-H
Vitotronic 200-H, HK1B Series
wall-mounted, digital indoor/outdoor heating circuit control
for one heating circuit with mixing valve and management of domestic hot
water production
with integrated diagnostic system
capable of communication via LON-BUS if equipped with LON
Communication Module (optional) with:
- Vitotronic 300, GW2B / GW5B / GW6B series
- Vitotronic 300-K, MW1B / MW2B / MW2C series
- Vitotronic 200-H, HK1B series
7172 926 Order No.
435.- US$

Mixing Valve Extension Module


Electronic circuit board for the 2. and 3. heating circuit
Up to 32 Vitotronic heating circuit controls may be controlled via LON-BUS
when equipped with communication module.
Important!
If integrating via LON-BUS with other Viessmann controls, the outdoor
temperature sensor of the master controller will be utilized. Therefore, the
outdoor temperature sensor shipped with this unit need then not be installed.

ZK01144 Order No.


2090. US$

Vitotronic 200-H, HK1B Series


with Viessmann Mixing Valve Motor, 120/1/60
for Viessmann 3- and 4-way mixing valves only
including strap-on supply temperature sensor (NTC 10 kOhm)
Standard Equipment:
Vitotronic 200-H (HK1B Series) with
1 outdoor temperature sensor
1 power supply adaptor 120V for mixing valve motor
1 Viessmann mixing valve motor with strap-on supply temperature sensor

Viessmann Mixing Valves

Viessmann 4-Way Mixing Valves

7134 736
328.

1
7134 737
350.

1
7134 738
391.

1
7134 739
435.

2
7133 018
534.

2 Dia
7133 019 Order No.
668. US$

Viessmann 3-Way Mixing Valves

7134 742
308.

1
7134 743
328.

1
7134 744
368.

1
7134 745
413.

2
7134 746
506.

Dia
Order No.
US$

Standard Equipment:
Drive shaft and separation plates
made of high-grade stainless steel,
internal parts made from copper
base alloy
Drive shaft and blade corrosion-resistant
- no danger of seizing up
Exchange of shaft gasket (O-ring) possible without
draining of heating system
NPT couplings

68

VITOTRONIC 200-H
HK1B Series

Wall-Mounted Heating Circuit Control

Vitotronic 200-H
Vitotronic 200-H, HK1B Series
wall-mounted, digital indoor/outdoor heating circuit control
for one heating circuit with mixing valve and management of domestic hot
water production
with integrated diagnostic system
capable of communication via LON-BUS if equipped with LON
Communication Module (optional) with:
- Vitotronic 300, GW2B / GW5B Series / GW6B series
- Vitotronic 300-K, MW1B / MW2B Series / MW2C series
- Vitotronic 200-H, HK1B series
7172 926 Order No.
435.- US$

Mixing Valve Extension Module


Electronic circuit board for the 2. and 3. heating circuit
Up to 32 Vitotronic heating circuit controls may be controlled via LON-BUS
when equipped with communication module.

Vitotronic 200-H, HK1B Series


with Danfoss Mixing Valve Motor, 24/1/60
for Danfoss 3-way mixing valves only

ZK01145 Order No.


2,956. US$

Standard Equipment:
Vitotronic 200-H (HK1B Series) with
1 outdoor temperature sensor
1 power supply adaptor 24V for mixing valve motor
1 Centra mixing valve motor

Danfoss Mixing Valves

Danfoss 3-Way Mixing Valves

2
ZK01698
1,001.

3
ZK01699
1,143.

4
ZK01700
1,506.

5
ZK01701
1,623.

6
ZK01702
2,056.

Dia
Order No.
US$

Standard Equipment:
Mixing valve
Flange set
Strap-on supply temperature sensor (NTC 10 kOhm)

This trademark is registered with the U.S. Patent and Trademark Office.

69

Vitotronic
200-H

Important!
If integrating via LON-BUS with other Viessmann controls, the outdoor
temperature sensor of the master controller will be utilized. Therefore, the
outdoor temperature sensor shipped with this unit need then not be installed.

VITOTRONIC 200-H
Accessories

Accessories

Remote Controls
7438 363
162.

Order No.
US$

7172 619
272.

Order No.
US$

Solar Module SM1


wall-mounted extension module with electronic differential control for use
with using solar collectors when used with oil/gas-fired heating boilers.
heating output balancing and diagnostic system
operation and display via boiler control
management of two tank systems from one collector field
second electronic differential control capability
thermostat function for supplemental heating or use of surplus heat
variable speed pump controller for solar circuit pump via pulse-width
control, or for solar circuit pump with PWM-input (mfg Grundfos)
includes one tank sensor and one collector sensor
120V, 60Hz, 2A in CSA housing, with 6.5 cord and 120V plug

7533 427
466.

Order No.
US$

Order immersion sensor 7438 702 if the following features are required:
for circulation management in systems with 2 storage tanks
for return flow management between boiler and hot water buffer tank
to supply heat to additional accessories

7438 702
87.

Order No.
US$

Vitotrol 200A
(KM-BUS protocol)
User interface to operate one heating circuit:
daytime temperature and operating program
with party and energy-saving button
display indication of outside temperature, room temperature and
operational settings
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)
If the Vitotrol 200A is to operate based upon room-dependent activation,
ensure placement in a centralized location.
Maximum 2 Vitotrols per Vitotronic.
Vitotrol 300A
(KM-BUS protocol)
User interface to operate one, two or three heating circuits:
daytime temperature, set-back temperature, DHW temperature, operating
and holiday program, as well as party and energy-saving function
timer program for heating circuits, DHW production, and DHW recirculation
pump
illuminated graphic display to show outdoor temperature, room
temperature, operational settings together with descriptive texts
with room temperature sensor for room-dependent activation
(for heating circuit with mixing valve only)
If the Vitotrol 300A is to operate based upon room-dependent activation,
ensure placement in a centralized location.
Order Room Temperature Sensor 7438537 if the Vitotrol 300 cannot be installed
in a centralized location.
Maximum 2 Vitotrols per Vitotronic.

Solar DHW Production and Supplemental Heating

70

VITOTRONIC 200-H
Accessories

Accessories

for installation for installation inside


inside Vitotronic
master control
200-H

with
Vitotronic 200, HO1B Series
as master control
LON Communication Module

7172 173
272.

7179 113
328.

Order No.
US$

with
Vitotronic 300, GW2B / GW6B Series1
as master control
LON Communication Module

7172 173
272.

7172 173
272.

Order No.
US$

with
Vitotronic 300-K, MW1B Series
as master control
LON Communication Module (included in boiler packages where >1 boiler
is ordered from the factory)

7172 173
272.

with
Vitotronic 300-K, MW2C Series
as master control
LON Communication Module

7172 173
272.

Order No.
US$

7172 174
308.

Order No.
US$

Communication
LON Connecting Cable, 23ft / 7m
for data exchange between controls

7143 495
52.

Order No.
US$

LON Extension Jack


to extend LON Connecting Cable

7143 496
34.

Order No.
US$

LON Connecting Terminal (RJ, 2 Pieces)


to connect to field cabling via wall-mount boxes

7171 784
76.

Order No.
US$

LON Terminal Resistor (2 Pieces)


to terminate the system BUS, a resistor must be installed on each free end

7143 497
14.

Order No.
US$

LON Communication Module


electronic circuit board enabling data communication via Viessmann LON
system BUS. For installation inside Vitodens 200-W.

7179 113
328.

Order No.
US$

7533 426
348.

Order No.
US$

Expanded Functions
Extension Module EA1
wall-mounted extension module whose inputs and outputs enable up to 5
additional functions:
*boiler set point temperature
1 Analog input (0-10V)
3 Digital Inputs
1 Output contact (potential-free)

this module is standard equipment in each Vitotronic 300, GW6B series control.

This trademark is registered with the U.S. Patent and Trademark Office.

71

Vitotronic
200-H

LON Communication Modules

VITOCOM 100
TeleControl - for IP Networks

Vitocom 100
Communication
Vitocom 100, LAN1 Series
For remote control of one heating system with Vitotronic control via IP Network (LAN).
Allows for hard wiring of internet connection for fast data transfer.

Operational Functions using Vitotrol-App


n
remote control of up to 3 heating circuits within a system.
n
setting of operational programs, setpoints and time programs of up to 3 heating circuits
within a heating system.
n
access to system information.
n
display of messages.
For additional information, see www.vitotrol-app.info.

Operational Functions using Vitodata 100


Remote Monitoring:
n
remote monitoring of all heating circuits within a system.
n
forwarding of messages via E-Mail to PC / Smartphone (E-Mail client required).
n
forwarding of messages via SMS to mobile phone / Smartphone or fax (via Vitodata Fault Management).
Remote Control:
n
access to all heating circuits within a system.
n
setting of operational programs, setpoints, time programs, and heating curves.
For additional information, see www.vitodata.info.

Communication:
n
via LON with Vitotronic control.
n
via LAN and internet with Vitodata Server.

Connections:
n
RJ 45 port to connect to LON.
n
120V adaptor with cable and wall plug.
n
RJ 45 port to connect to the IP network (LAN).

Controls Compatible with Vitotrol-App:


(for a heating system without subordinate heating circuits.)
Controls for floor-standing boilers:
n
Vitotronic 100, GC1B Series
n
Vitotronic 300, GW2B, GW5B and GW6B Series
Controls for wall-mounted boilers:
n
Vitotronic 200, HO1B Series

72

VITOCOM 100
TeleControl - for IP Networks

Vitocom 100
Communication
Vitocom 100, LAN1 Series
Controls Compatible with Vitodata 100:
Controls for floor-standing boilers:
(for single- or multiple-boiler systems with maximum 30 heating circuits)
n
Vitotronic 100, GC1B Series
n
Vitotronic 300, GW2B, GW5B and GW6B Series
n
Vitotronic 300-K, MW1B Series
Controls for wall-mounted boilers:
n
Vitotronic 200, HO1B Series
n
Vitotronic 300-K, MW2B / MW2C Series
Controls for heating circuits:
n
Vitotronic 200-H, HK1B
Important!
n
Please verify system requirements for communication via IP network (LAN) prior to startup.
n
An internet connection with ungoverned speed and data volume is required to operate
Vitocom using an IP network (LAN).
For additional information, see www.vitodata.info.
Vitocom 100, LAN1 Series
communication via Internet and IP network (LAN) with DSL router.
Compact unit for wall mount.

7501 472
435.

Order No.
US$

Z011224
535.

Order No.
US$

Standard Equipment:
n
Vitocom 100, LAN1 with LAN connector.
n
data cables for LAN and communication module.
n
120V adaptor with cable and wall plug.
n
Vitodata 100 Fault Management for a duration of 3 years.
Important:
Requires LON Communication module, ensure that control is equipped with the appropriate
Viessmann LON communication module.
Vitocom 100, LAN1 Series with Communication Module
communication via Internet and IP network (LAN) with DSL router.
Compact unit for wall mount.
Standard Equipment:
n
Vitocom 100, LAN1 with LAN connector.
n
communication module for installation inside a connected Vitotronic control.
n
data cables for LAN and communication module.
n
120V adaptor with cable and wall plug.
n
Vitodata 100 Fault Management for a duration of 3 years.

This trademark is registered with the U.S. Patent and Trademark Office.

73

VERSATRONIK
Gateways for Building Management Systems

Versatronik

System Configuration
for Product Series

Gateway
Max. No.
of Target
Devices

Cascade
Control
Required 1

Boiler
Comm.
Card
Required

Cascade
Comm.
Card
Required

Our gateways are designed to integrate equipment and devices that use nonstandard or proprietary HVAC protocols like LON, OpenTherm, MODBus, and RESOL
with Building Management and Automation Systems utilizing industry standard
communication protocols, e.g. BACNet. Gateways are valuable tools for system
integrators and engineers who need to read, relay and control multiple variables
and parameters between different building subsystems, all the while monitoring
building systems from a central or remote location.
Versatronik 501 NR2/LON

B2HB

Yes

KMK

LON

CM2, VD2A, VD2, CT3

Yes

LON

LON

B2HA/B2HB

Yes

KMK

LON

CM2, VD2A, VD2, CT3

Yes

LON

LON

B2HA/B2HB

Yes

KMK

LON

CM2, VD2A, VD2, CT3

Yes

LON

LON

Versatronik 521 OT/LON

WB1B

No

No

N/A

7521 348 Order No.


1,363. US$

Versatronik 522 OT/MODBUS

WB1B

No

No

N/A

7521 349 Order No.


1,074. US$

Versatronik 525 OT/BACIP

WB1B

No

No

N/A

7521 350 Order No.


1,321. US$

Versatronik 531 Solar/LON 2

SCU 124 / 224 / 345,


SEM

N/A

N/A

N/A

7521 351 Order No.


1,062. US$

Versatronik 532 Solar/MODBUS 2


(RS 485)

SCU 124 / 224 / 345,


SEM

N/A

N/A

N/A

7521 352 Order No.


1,223 US$

Versatronik 535 Solar/BACIP 2


(RS 485)

SCU 124 / 224 / 345,


SEM

N/A

N/A

N/A

7521 353 Order No.


1,347. US$

Versatronik 511 NR2/LON

B2HA/B2HB, CM2,
VD2A, VD2, CT3

16

No

LON

N/A

7521 354 Order No.


2,622. US$

Versatronik 515 NR2/BACIP

B2HA/B2HB, CM2,
VD2A, VD2, CT3

16

No

LON

N/A

7521 355 Order No.


2,839. US$

Versatronik 512 NR2/MODBUS


(RS 485)

Versatronik 505 NR2/BACIP

7521 345 Order No.


2,622. US$

7521 346 Order No.


2,622. US$

7521 347 Order No.


2,839. US$

Viessmann cascade controls include: Vitotronic 300-K MW2B, MW2C, Vitotronic 300-K MW1B, and Vitocontrol-S.
Compatible with Resol products only.
ffVersatronik gateways are not compatible with the Viessmann Solar Module SM1 7533 427 or the Viessmann Vitotronic 300, GW6B
control 7542 124.

1
2

Overview of Datapoints:
Boiler setpoint (writable)
DHW setpoint (writable)
Boiler water temperature
Modulation level
Current modulation level

74

Room setpoint temperature


Outside temperature
Boiler heat exchanger temperature
DHW setpoint
C or F selectable

OEM diagnostic codes


Boiler faults
Flame status
and more - see technical literature

Low-Loss
Headers

Low-Loss Headers
for commercial installations

Low-Loss Header, Model 160/80


(not exactly as illustrated)

Low-Loss Headers

To decouple high flow rate systems from the boiler loop.

Vertical mixing chamber of steel with supply and return tapping for
both heat source and heat destination.

Enables constant flow through boiler.


Avoids flow problems in secondary heating circuits.
Promotes boiler condensation when used
with condensing boilers.
Protect boiler heat exchanger.
Helps eliminate air, sediment, and debris
from the heating system.
Stand-by losses minimized by highly effective
foamed-in-place or mineral wool insulation.
Used as a separation point between boiler and
system loop for troubleshooting purposes.

This trademark is registered with the U.S. Patent and Trademark Office.

75

Low-Loss Headers
Not for use with multiple boiler low-loss distribution manifold

Model
Header
Low-Loss Header Model 80/60
with insulation
to decouple high flow rate systems from the boiler loop.
Max. flow rate 19.5 USGPM / 4.4 m3/hr
1 NPT connections
2 x 11 x 23 / 50 x 280 x 585 mm

Insul.
7498 529
290.

Low-Loss Header Model 120/80


with insulation
to decouple high flow rate systems from the boiler loop.
Max. flow rate 35 USGPM / 8 m3/hr
2 NPT connections
3 x 12 x 36
80 x 320 x 930 mm

7498 530
435.

Low-Loss Header Model 160/80


Max. Flow Rate:
44 USGPM / 10 m3/hr
Insulation: PUR Foam 1

Stock

Low-Loss Header Model 200/120


Max. Flow Rate:
80 USGPM / 18 m3/hr
Insulation: PUR Foam 1

Stock

Low-Loss Header Model 250/150


Max. Flow Rate:
119 USGPM / 27 m3/hr
Insulation: PUR Foam 1

Stock

Low-Loss Header Model 300/200


Max. Flow Rate:
189 USGPM / 43 m3/hr
Insulation: PUR Foam 1

Stock

Low-Loss Header Model 400/200


Max. Flow Rate:
251 USGPM / 57 m3/hr
Insulation: Mineral Wool 2

Stock

Low-Loss Header Model 450/250


Max. Flow Rate:
374 USGPM / 85 m3/hr
Insulation: Mineral Wool 2

Lead time: 6 weeks

Low-Loss Header Model 500/300


Max. Flow Rate:
484 USGPM / 110 m3/hr
Insulation: Mineral Wool 2

Lead time: 6 weeks

Low-Loss Header Model 600/400


Max. Flow Rate:
748 USGPM / 170 m3/hr
Insulation: Mineral Wool 2

Lead time: 6 weeks

Low-Loss Header Model 650/450


Max. Flow Rate:
1034 USGPM / 235 m3/hr
Insulation: Mineral Wool 2

Lead time: 6 weeks

Low-Loss Header Model 700/500


Max. Flow Rate:
1320 USGPM / 300 m3/hr
Insulation: Mineral Wool 2

Lead time: 6 weeks

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

Order No.
US$

Order No.
US$

7834 470 7834 480 Order No.


1,053.
499. US$
100
40 lbs
45
18 kg
7834 471 7834 481 Order No.
1,346.
650. US$
137
44 lbs
62
20 kg
7834 472 7834 482 Order No.
1,505.
736. US$
185
46 lbs
84
21 kg
7834 473 7834 483 Order No.
1,673.
823. US$
276
53 lbs
125
24 kg
7834 474 7834 484 Order No.
1,995.
887. US$
340
60 lbs
154
26 kg
7834 475 7834 485 Order No.
3,429.
1,122. US$
595
77 lbs
270
34 kg
7834 476 7834 486 Order No.
4,075.
1,269. US$
860
95 lbs
390
42 kg
7834 477 7834 487 Order No.
5,790.
1,764. US$
1213
112 lbs
550
51 kg
7834 478 7834 488 Order No.
8,105.
2,257. US$
1543
128 lbs
700
58 kg
7834 479 7834 489 Order No.
10,697.
2,313. US$
1610
157 lbs
730
71 kg

For Low-Loss Header sizing, please see Technical Data Manual.


1
2

PUR rigid foam insulation consists of two aluminum half-shells, containing 65mm PUR foam, and cut-outs for all connections.
Mineral wool insulation consists of two aluminum half-shells, containing 100mm mineral wool, and cut-outs for all connections.

76

Low-Loss Headers

Model
Connection

Total
Height

Total
Width

Total
Depth

L1

L2

L3

L4

2 ANSI Flange

56.7
1440

22.1
560

11
280

39.4
1000

15.3
390

3.8
97

12.2
310

inches
mm

Model 200/120

3 ANSI Flange

57
1450

23.7
600

12.6
320

39.4
1000

15.3
390

3.8
97

13.8
350

inches
mm

Model 250/150

4 ANSI Flange

57.8
1468

25.6
650

13.8
350

39.4
1000

15.7
400

4.2
107

15.7
400

inches
mm

Model 300/200

5 ANSI Flange

58.3
1481

27.6
700

15.7
400

39.4
1000

15.7
400

4.2
107

17.7
450

inches
mm

Model 400/200

6 ANSI Flange

58.9
1495

31.5
800

15.7
400

39.4
1000

15.7
400

4.2
107

21.7
550

inches
mm

Model 450/250

8 ANSI Flange

59.8
1520

33.5
850

17.7
450

39.4
1000

15.7
400

4.2
107

23.6
600

inches
mm

Model 500/300

8 ANSI Flange

71.6
1819

35.5
900

19.7
500

47.2
1200

19.7
500

4.2
107

25.6
650

inches
mm

Model 600/400

10 ANSI Flange

72.6
1845

39.4
1000

23.6
600

47.2
1200

19.7
500

4.2
107

30
760

inches
mm

Model 650/450

12 ANSI Flange

76.6
1945

41.4
1050

25.6
650

47.2
1200

22.4
570

4.2
107

32.7
830

inches
mm

Model 700/500

14 ANSI Flange

90.2
2291

43.4
1100

27.6
700

59
1500

22.4
570

4.2
107

33.9
860

inches
mm

Model 160/80

Diagram

L3

L2

Total Depth

Total Height

L1

Total Width

A Boiler supply (top) and boiler return (bottom)


B System supply (top) and system return (bottom)
C Air vent tapping
D Sensor well tapping
E Drain/flush tapping
F Anchor bolt holes
ANSI counter flanges are field supplied.

This trademark is registered with the U.S. Patent and Trademark Office.

77

Low-Loss
Headers

Technical Data

Hydronic Heating Accessories


Transport

Accessories

Transport
Two-Wheel Truck

9521 645
1,413.
Net Price

Order No.
US$

Transport Panel for Vitorond 100 boilers (only) up to size -33


for use with Viessmann Two-Wheel Truck (above), or other dolly
not required if boiler is transported inside its factory crating

7198 575
102.
Net Price

Order No.
US$

Carrying Handles for boilers up to size -63

7517 308
78.
Net Price

Order No.
US$

Carrying Handles for Vitorond 100 boilers (only) up to size -33

7189 602
78.
Net Price

Order No.
US$

Carrying Handles for Vitocell-H domestic hot water tanks up to 53 USG / 200 Ltr.

7517 478
40.
Net Price

Order No.
US$

Lifting Harness for Vitosol 100-F / 200-F


2 Lifting Rails c/w straps

7188 503
147.
Net Price

Order No.
US$

7334 502
19.10
Net Price

Order No.
US$

special two-wheel truck for Viessmann boilers


and domestic hot water tanks
for use across flat surfaces and up/down stairs
carries weight of up to 850 lbs / 400 kg (max.)
with special carrying bracket for Vitola boilers

(Vitola 200 only)


4 Carrying Handles

4 Carrying Handles

4 Carrying Handles

Mechanical Room
Service Box

protective box, color: vitosilver, for technical literature storage in the mechanical room.
For installation on the boiler or on the wall

78

VITOSOL

Vitosol

Solar Collectors
to harness solar energy

Vitosol Solar Collectors the right solution for every application

Vitosol 100-F
Vitosol 200-F

Using solar energy to produce domestic hot water, or to


supplement low-temperature space heating or pool heating
systems, via a heat-exchanger

Vitosol 200-T

Flat plate collector


for vertical, angled, free-standing, or wall-mount installation.

Vacuum tube solar collector


utilizing the heat pipe principle, for vertical, horizontal, angled,
free-standing, or wall-mount installation.

This trademark is registered with the U.S. Patent and Trademark Office.

79

Vitosol DHW Solar Pack


Vitosol 200-F, SVK Series
Vitocell 100-B, CVBA Series with integrated Solar-Divicon and Deltasol BX control
System Componetry

Series

Coll. Qty
Area
Install.

Tank Vol.
Name
Color

Pump and
Control

SVK

2
Collectors

66 USG
250 Ltr

Grundfos
Solar
3-speed
16-68
pump

47 ft2
4.36 m2

Vitocell
100-B

Deltasol
BX
control

Sloped,
shingled
roof
hardware

White

SK05094
4,781.-

D
A
B
C
D
E
F
G

Solar collectors
Mounting hardware for sloped, shingled roofs
Solar-Divicon (preinstalled on DHW storage tank)
Domestic cold water inlet
Solar control unit
Domestic hot water outlet
Bivalent DHW storage tank

Standard Equipment of Vitosol DHW Solar Pack:


Two x Vitosol 200-F, SVK Series including connection set with collector sensor
Mounting hardware for sloped, shingled roofs
Vitosol 100-B, CVBA Series bivalent storage tank with preinstalled Solar-Divicon including 3-speed pump for
the solar loop, Deltasol BX control, air separator, flow meter, pressure relief valve, pressure gage, and system fill manifold
Expansion tank, 4.8 USG / 18 L including mounting bracket and flexible stainless steel connection pipe
Tyfocor solar system fill, 5.3 USG / 20 L
Individual system crating

80

Order No.
US$

Vitosol DHW Solar Pack


Technical Data

Series
SVK

Absorber Area

Gross Area

Aperture Area Flat Collector

Collector Dimensions
(width x height x depth)
Weight

Technical Data
Vitocell 100-W
incl. Solar-Divicon

21.64
2.01

ft2
m2

23.47
2.18

ft2
m2

21.74
2.02

ft2
m2

41 x 81 x 3
1056 x 2066 x 73

ft2
m2

82
37

ft2
m2

Series

Capacity

Tank Dimensions
(width x length x height)
Weight

CVBA
66
250

USG
ltr

33 x 24 x 58
860 x 631 x 1485

inches
mm

273
124

Vitosol

Technical Data
Vitosol 200-F
single collector

lb
kg

Flexible Insulated Piping


Systems (See also pg 93)

Solar Supply/Return Piping Kit, 50 / 15m

7511 569
768.

Order No.
US$

Solar Supply/Return Piping Kit, 40 / 12m

7511 568
675.

Order No.
US$

Solar Supply/Return Piping Kit, 20 / 6m

7511 567
403.

Order No.
US$

This trademark is registered with the U.S. Patent and Trademark Office.

81

VITOSOL

Solar Systems

Product Offering

Solar collectors - reliable, efficient, easy to install, and durable


Solar-Divicon preassembled pumping station
Dual-coil DHW storage tanks
Solar control unit
Quick-connect fittings and system components
Solar expansion tank
Premixed solar Glycol fluid

System Optimization

A high quality collector


alone cannot guarantee
the optimum operation of
a solar installation. This
depends more on the
system solution as a whole.
Viessmann supplies all the
components required for a
complete solar heating
system:

a control unit tailored to


the individual solar
heating system
a DHW storage tank with
a second solar heat
exchanger
system components
aimed at speedy
installation and optimum
system performance.

Properly designed solar


heating systems with well
matched system
components can cover
50 to 60% of the annual
energy demand for DHW
heating in single family
homes. We are pleased to
assist you with the design
of solar heating systems.
The elements of a solar
heating system are shown
in the diagram below.

Single Tank (dual-coil)


System Example

N
M

B
L

K
F

H
DHW

DCW

A Solar collector
B Solar-Divicon

C
D
E
F

preassembled pumping station


with integrated system fill manifold and
automatic air vent with air separator
Spill container (field supplied)
Solar expansion tank
Manual fill pump
System fill manifold valve

82

G
H
I
K
L
M
N
O
T

Brass elbow with sensor well


Dual-coil DHW storage tank
Tank temperature sensor
Air separator
Solar control unit
Flexible connection pipe
Collector temperature sensor
Fast air vent
Tyfocor premixed solar fill
(not shown above)

R Solar return
S Solar supply

Important!
Additional materials for installation
must be field supplied. Never use plastic,
steel or galvanized pipes or fittings;
use copper, stainless steel or brass only!
All connections to be soldered or made with
compression fittings.

VITOSOL
Viessmann Combi-Packages

One-Tank System

Solar System
consisting of:
Solar Collector

Vitosol 200-F, SV2 Series


Total 49.5 ft2 / 4.6 m2

Two-Tank System

CombiPkg 1

CombiPkg 2

CombiPkg 3

SK05200
6,160.

SK04169
6,602.

SK05201
5,770.

SK04170 Order
6,194. No.
US$

2x
7537 739

Qty
Order
No.

2x
7537 739

1x
SK03689

Vitosol 200-T, SP2A Series


Total 32.6 ft2 / 3.03 m2
(24 tubes)

1 x Qty
SK03689 Order
No.

Interconnection Pipe (1 Pair)


between collectors

1x
7248 239

General Connection Set


for field ends

1x
7248 240

Sensor Well Set


(for Vitosol 200-F only)

1x
7174 993

Mounting Hardware
for sloped, shingled roofs

1x
Z003 098

1x
ZK00589

1x
Z003 098

1 x Order
ZK00589 No.

1x
7427 617

1x
7533 718

1x
7427 617

1 x Order
7533 718 No.

Installation Fittings Set 1


to adapt from metric to pipe
Solar-Divicon
B
preassembled pumping station
with integrated system fill
manifold and automatic air vent
with air separator

DN20 with Star 16U-15


circulation pump

DHW Storage Tank

Vitocell-B 100
dual-coil DHW storage tank
with 79 USG / 300 ltr capacity

1x
7248 239

N/A
1x
7510 994

1x
7248 240
1x
7174 993

N/A

Brass Elbow with sensor well G


for tank temperature sensor

N/A

Order
No.

1 x Order
7510 994 No.

N/A

1x
7134 799
668.

Order
No.

Order
No.

1x
7134 448
2,375.

Order
No.

Vitocell-V 100
single-coil DHW storage tank
with 79 USG / 300 ltr capacity
included with
DHW tank (above)

1x
7134 162
1,950.

Order
No.

1x
7175 213
35.

Order
No.

L
I
DHW temperature sensor
collector temperature sensor N

1x
7439 303
315.

Order
No.

Solar Expansion Tank, 25L


with mounting hardware

1x
7248 242
174.

Order
No.

Fast Air Vent with shut-off


O
valve, brass piping tee and brass
compression couplings ( 22mm)

1x
7316 789
67.

Order
No.

1x
7316 098
135.

Order
No.

Solar Control Unit SCU124

Tyfocor-HTL Solar Fill

CombiPkg 4

5.28 USG / 20 Ltr.


premixed for protection to -31F / -35C

Installation fittings set includes all installation manuals and an adaptor fitting for expansion tank.

This trademark is registered with the U.S. Patent and Trademark Office.

83

Vitosol

Viessmann
Combi-Packages

VITOSOL 100-F
Flat Plate Solar Collectors

Solar Collectors
Vertical

Collector Absorber Area

24.8
2.3

49.5
4.6

74.3
6.9

99.0
9.2

123.8
11.5

145.3
13.5

198.1
18.4

247.6 ft2
23.0 m2

SV1B Series collectors are designed to be mounted vertically.


Pipe connections are on the long edge of collector.

Vitosol 100-F, SV1B Series


Vertical flat plate collectors

1x

2x

3x

4x

5x

6x

8x

10x Qty

7417 767
List Price
Interconnection Pipes (1 pair)

Order No.

809.

1,618.

2,427.

3,236.

4,045.

4,854.

6,472.

1x

2x

3x

4x

5x

7x

between collectors

8,090. US$ Ttl.


9x Qty

7248 239

List Price

52.

104.

156.

Order No.
208.

260.

364.

468. US$ Ttl.

General Connection Set


for a collector field of up to 12
collectors

7248 240
100.

Order No.
US$

Sensor Well Set


(one required per collector field)

7174 993
52.

Order No.
US$

Installation Fittings Set 1


to adapt from metric to pipe
(one required per solar system)

7427 617
67.

Order No.
US$

Technical Data
Collector Dimensions
(width x height x depth)
Frame Construction

41 x 93 x 2

inches

non coated aluminum

inches

Mounting Accessories
Vertical

Required hardware with corresponding collector count


1

Mounting Hardware
for sloped, shingled roofs

Z003 097
186.

Z003 098
311.

Z003 099
448.

Z003 100
582.

Z003 101
725.

Z003 102
853.

Mounting Rack c/w Hardware 2


for a free-standing, flat roof
installation, mounted to
substructure.
Collector angle: 25 - 60

Z003 145 Z003 146 Z003 147 Z003 148 Z003 149 Z003 150 Z003 151 Z003 152 Order No.
412.
824.
1,236.
1,648.
2,060.
2,472.
3,340.
4,164. US$ Ttl.

1
2

Installation fittings set includes all installation manuals and an adaptor fitting for expansion tank.
Substructure material (to which mounting rack attaches) must be field supplied.

84

10

Z003 103 Z003 104 Order No.


1,130.
1,401. US$ Ttl.

VITOSOL 100-F
Flat Plate Solar Collectors

Solar Collectors
Horizontal

Collector Absorber Area

24.8
2.3

49.5
4.6

74.3
6.9

99.0
9.2

123.8
11.5

145.3
13.5

198.1
18.4

247.6 ft2
23.0 m2

SH1B Series collectors are designed to be mounted horizontally.


Pipe connections are on the short edge of collector.
Vitosol 100-F, SH1B Series
horizontal flat plate collectors

1x

2x

3x

4x

5x

6x

8x

10x Qty

7417 768
List Price
Interconnection Pipes (1 pair)

Order No.

809.

1,618.

2,427.

3,236.

4,045.

4,854.

6,472.

1x

2x

3x

4x

5x

7x

between collectors

8,090. US$ Ttl.


9x Qty

7248 239

List Price

52.

104.

156.

Order No.
208.

260.

364.

468. US$ Ttl.

General Connection Set


for a collector field of up to 12
collectors

7248 240
100.

Order No.
US$

Sensor Well Set


(one required per collector field)

7174 993
52.

Order No.
US$

Installation Fittings Set 1


to adapt from metric to pipe
(one required per solar system)

7427 617
67.

Order No.
US$

Collector Dimensions
(width x height x depth)
Frame Construction

93 x 41 x 2

inches

non coated aluminum

inches

Vitosol
100-F

Technical Data

Mounting Accessories
Horizontal

Required hardware with corresponding collector count


1

Mounting Hardware
for sloped, shingled roofs

Z003 169
245.

Z003 170
458.

Z003 171
663.

Z003 172
876.

Z003 173
1,087.

Z003 174
1,294.

Mounting Rack c/w Hardware 2


for a free-standing, flat roof
installation, mounted to
substructure.
Collector angle: 25 - 45

Z003 225 Z003 226 Z003 227 Z003 228 Z003 229 Z003 230 Z003 231 Z003 232 Order No.
282.
564.
846.
1,128.
1,410.
1,692.
2,300.
2,864. US$ Ttl.

Mounting Rack c/w Hardware 2


for a free-standing, flat roof
installation, mounted to
substructure.
Collector angle: 50 - 80

Z005 467 Z005 468 Z005 469 Z005 470 Z005 471 Z005 472 Z005 473 Z005 474 Order No.
307.
623.
939.
1,255.
1,571.
1,887.
2,554.
3,186. US$ Ttl.

Mounting Rack c/w Hardware 2


for vertical (wall) installation
Angle from wall: 10-45

Z005 475 Z005 476 Z005 477 Z005 478 Z005 479 Z005 480 Z005 481 Z005 482 Order No.
290.
624.
958.
1,292.
1,626.
1,960.
2,628.
3,296. US$ Ttl.

1
2

10

Z003 175 Z003 176 Order No.


1,718.
2,136. US$ Ttl.

Installation fittings set includes all installation manuals and an adaptor fitting for expansion tank.
Substructure material (to which mounting rack attaches) must be field supplied.

This trademark is registered with the U.S. Patent and Trademark Office.

85

VITOSOL 200-F
Flat Plate Solar Collectors

Solar Collectors
Vertical

Collector Absorber Area

24.8
2.3

49.5
4.6

74.3
6.9

99.0
9.2

123.8
11.5

145.3
13.5

198.1
18.4

247.6 ft2
23.0 m2

SV2C Series collectors are designed to be mounted vertically.


Pipe connections are on the long edge of collector.
Vitosol 200-F, SV2C Series
Vertical flat plate collectors

1x

2x

3x

4x

5x

6x

8x

10x Qty

7537 739
List Price
Interconnection Pipes (1 pair)

Order No.

922.

1,844.

2,766.

3,688.

4,610.

5,532.

7,376.

1x

2x

3x

4x

5x

7x

between collectors

9,220. US$ Ttl.


9x Qty

7248 239

List Price

52.

104.

156.

Order No.
208.

260.

364.

468. US$ Ttl.

General Connection Set


for a collector field of up to 12
collectors

7248 240
100.

Order No.
US$

Sensor Well Set


(one required per collector field)

7174 993
52.

Order No.
US$

Installation Fittings Set 1


to adapt from metric to 3/4 pipe
(one required per solar system)

7427 617
67.

Order No.
US$

Technical Data
41 x 93 x 3

Collector Dimensions
(width x height x depth)

inches

Blue powder-coated aluminum

Frame Construction

Mounting Accessories
Vertical

Required hardware with corresponding collector count


1

Mounting Hardware
for sloped, shingled roofs

Z003 097
186.

Z003 098
311.

Z003 099
448.

Z003 100
582.

Z003 101
725.

Z003 102
853.

Mounting Rack c/w Hardware 2


for a free-standing, flat roof
installation, mounted to
substructure.
Collector angle: 25 - 60

Z003 145 Z003 146 Z003 147 Z003 148 Z003 149 Z003 150 Z003 151 Z003 152 Order No.
412.
824.
1,236.
1,648.
2,060.
2,472.
3,340.
4,164. US$ Ttl.

1
2

Installation fittings set includes all installation manuals and an adaptor fitting for expansion tank.
Substructure material (to which mounting rack attaches) must be field supplied.

86

10

Z003 103 Z003 104 Order No.


1,130.
1,401. US$ Ttl.

VITOSOL 200-F
Flat Plate Solar Collectors

Solar Collectors
Horizontal

Collector Absorber Area

24.8
2.3

49.5
4.6

74.3
6.9

99.0
9.2

123.8
11.5

145.3
13.5

198.1
18.4

247.6 ft2
23.0 m2

SH2C Series collectors are designed to be mounted horizontally.


Pipe connections are on the short edge of collector.
Vitosol 200-F, SH2C Series
Horizontal flat plate collectors

1x

2x

3x

4x

5x

6x

8x

10x Qty

7537 738
List Price
Interconnection Pipes (1 pair)

Order No.

922.

1,844.

2,766.

3,688.

4,610.

5,532.

7,376.

1x

2x

3x

4x

5x

7x

between collectors

9,220. US$ Ttl.


9x Qty

7248 239

List Price

52.

104.

156.

Order No.
208.

260.

364.

468. US$ Ttl.

General Connection Set


for a collector field of up to 12
collectors

7248 240
100.

Order No.
US$

Sensor Well Set


(one required per collector field)

7174 993
52.

Order No.
US$

Installation Fittings Set 1


to adapt from metric to pipe
(one required per solar system)

7427 617
67.

Order No.
US$

Technical Data
93 x 41 x 3

Collector Dimensions
(width x height x depth)

inches

Vitosol
200-F

Blue powder-coated aluminum

Frame Construction

Mounting Accessories
Horizontal

Required hardware with corresponding collector count


1

Mounting Hardware
for sloped, shingled roofs

Z003 169
245.

Z003 170
458.

Z003 171
663.

Z003 172
876.

Z003 173
1,087.

Z003 174
1,294.

Mounting Rack c/w Hardware 2


for a free-standing, flat roof
installation, mounted to
substructure.
Collector angle: 25 - 45

Z003 225 Z003 226 Z003 227 Z003 228 Z003 229 Z003 230 Z003 231 Z003 232 Order No.
282.
564.
846.
1,128.
1,410.
1,692.
2,300.
2,864. US$ Ttl.

Mounting Rack c/w Hardware 2


for a free-standing, flat roof
installation, mounted to
substructure.
Collector angle: 50 - 80

Z005 467 Z005 468 Z005 469 Z005 470 Z005 471 Z005 472 Z005 473 Z005 474 Order No.
307.
623.
939.
1,255.
1,571.
1,887.
2,554.
3,186. US$ Ttl.

Mounting Rack c/w Hardware 2


for vertical (wall) installation
Angle from wall: 10 - 45

Z005 475 Z005 476 Z005 477 Z005 478 Z005 479 Z005 480 Z005 481 Z005 482 Order No.
290.
624.
958.
1,292.
1,626.
1,960.
2,628.
3,296. US$ Ttl.

1
2

10

Z003 175 Z003 176 Order No.


1,718.
2,136. US$ Ttl.

Installation fittings set includes all installation manuals and an adaptor fitting for expansion tank.
Substructure material (to which mounting rack attaches) must be field supplied.

This trademark is registered with the U.S. Patent and Trademark Office.

87

VITOSOL 200-T
SPE Series
Heat Pipe Vacuum Tube Solar Collectors
Solar Collectors
Collector Absorber Area
Vitosol 200-T, SPE 1.63 m2 Series
vacuum tube collector with 9 tubes
Vitosol 200-T, SPE 3.26 m2 Series
vacuum tube collector with 18 tubes

17.55
1.63
SK03558
1,277.

35.09 ft2
3.26 m2
Order No.
US$

SK03559 Order No.


2,515. US$

Installation Fitting Set1


to adapt from metric to pipe (one required per solar system)

7533 717
65.

Order No.
US$

General Connection Set


for a collector field of up to 108 tubes / 20 m2 collector absorber area (one required per collector field)

7507 740
43.

Order No.
US$

Interconnection pipe (1 pc)


for connecting collectors together. Including thermal insulation.

7507 739
43.

Order No.
US$

Technical Data
Collector Absorber Area
Number of Tubes

17.55
1.63

35.09 ft2
3.26 m2

18

Gross Area

28.6

57.3 ft2

Aperture Area Tube Collector

18.8

37.6 ft2

Width

48

94 inches

Height

88

88 inches

Depth

6 inches

Weight

126

249 lb

Single Parts For Installation


Collector Absorber Area
Spare Parts Set
assortment of spare parts which may get lost during installation.
1

Installation fittings set includes all installation manuals and an adaptor fitting for expansion tank.

ffDHW tanks for solar systems can be found on Page 92 (Vitosol Storage)
ffInstallation accessories can be found on Page 93 (Vitosol Accessories)
ffSolar system controls can be found on Page 90 (Vitosol Controls)

88

17.55
1.63

35.09 ft2
3.26 m2

7507 763
5.40

Order No.
US$

VITOSOL 200-T
SPE Series
Heat Pipe Vacuum Tube Solar Collectors
Mounting Accessories
Vertical Mounting Accessories

Installation on sloped roofs


Required hardware with corresponding
collector absorber area
Mounting Hardware
(tubes vertical)
for a sloped, shingled roof

17.55
1.63

35.09 ft2
3.26 m2

ZK00589
195.

Order No.
US$

Installation on flat roofs


Required hardware with corresponding
collector absorber area

35.09 ft2
3.26 m2

Mounting Hardware
(tubes vertical, laying flat)
for a flat roof installation, mounted to substructure1
collector angle 0 (laid flat)

ZK00576
115.

Order No.
US$

Mounting Hardware
(tubes vertical, angled)
for a free-standing, flat roof installation, mounted to substructure1
fixed collector angle 30 (non-adjustable)
snow loads up to 31.3 lb/ft2
wind speed up to 93 mp/h

ZK00573
251.

Order No.
US$

Mounting Hardware
(tubes vertical, angled)
for a free-standing, flat roof installation, mounted to substructure1
fixed collector angle 45 (non-adjustable)
snow loads up to 31.3 lb/ft2
wind speed up to 93 mp/h

ZK00574
251.

Order No.
US$

Mounting Hardware
(tubes vertical, angled)
for a free-standing, flat roof installation, mounted to substructure1
fixed collector angle 60 (non-adjustable)
snow loads up to 31.3 lb/ft2
wind speed up to 93 mp/h

ZK00575
251.

Order No.
US$

Vitosol
200-T SPE

17.55
1.63

Substructural material (to which mounting rack is attached to) must be field supplied.

Horizontal Mounting Accessories

Installation on sloped roofs


Required hardware with corresponding
collector absorber area
Mounting Hardware
(tubes horizontal)
for a sloped, shingled roof

This trademark is registered with the U.S. Patent and Trademark Office.

17.55
1.63

35.09 ft2
3.26 m2

ZK00583
250.

Order No.
US$

89

VITOSOL 200-T
SP2A Series
Heat Pipe Vacuum Tube Solar Collectors
Solar Collectors

Collector Absorber Area


13.56
1.26

Vitosol 200-T, SP2A 1.26 m2 Series


vacuum tube collector with 10 tubes

SK03687
1,067.

Vitosol 200-T, SP2A 1.51 m2 Series


vacuum tube collector with 12 tubes

N/A

Vitosol 200-T, SP2A 3.03 m2 Series


vacuum tube collector with 24 tubes

16.25
1.51
N/A
SK03688
1,278.

N/A

32.61 ft2
3.03 m2
N/A

Order No.
US$

N/A

Order No.
US$

SK03689 Order No.


2,524. US$

N/A
7533 718
65.

Installation Fitting Set1


to adapt from metric to pipe (one required per solar system)
Interconnection pipe (1 pair)
for connecting collectors together. Including thermal insulation and hydraulic cover.

N/A

General Connection Set with u-pipe


with thermal insulation and u-pipe covers
for a collector field of up to 96 tubes / 15 m2 collector absorber area
(one required per collector field)

N/A

Order No.
US$

7510 993
43.

Order No.
US$

7510 994
84.

Order No.
US$

7510 996
105.

General Connection Set with air vent u-pipe


with thermal insulation and air vent u-pipe covers
for a collector field of up to 96 tubes / 15 m2 collector absorber area
for mounting on walls or balconies (piping connections from below)
(one required per collector field)

Order No.
US$

Technical Data
Collector Absorber Area

13.56
1.26

16.25
1.51

10

12

Gross Area

21.3

25.4

49.7 ft2

Aperture Area Tube Collector

14.3

17.2

34.3 ft2

Width

34

411/2

811/4 inches

Height

881/4

881/4

881/4 inches

Depth

5 inches

Weight

73

86

174 lb
kg

Number of Tubes

Installation fittings set includes all installation manuals and an adaptor fitting for expansion tank.
ffDHW tanks for solar systems can be found on Page 92 (Vitosol Storage)
ffInstallation accessories can be found on Page 93 (Vitosol Accessories)
ffSolar system controls can be found on Page 90 (Vitosol Controls)

90

32.61 ft2
3.03 m2
24

VITOSOL 200-T
SP2A Series
Heat Pipe Vacuum Tube Solar Collectors
Vertical Mounting Accessories
Vertical Mounting Accessories

Installation on sloped roofs


Required hardware with corresponding
collector absorber area

16.25
1.51

32.61 ft2
3.03 m2

ZK00589
195.

Mounting Hardware
(tubes vertical)
for a sloped, shingled roof

Order No.
US$

Installation on flat roofs


16.25
1.51

Mounting Hardware
(tubes vertical, laying flat)
for a flat roof installation, mounted to substructure1
collector angle 0 (laid flat)

ZK00576
115.

Order No.
US$

Mounting Hardware
(tubes vertical, angled)
for a free-standing, flat roof installation, mounted to substructure1
fixed collector angle 30 (non-adjustable)
snow loads up to 31.3 lb/ft2
wind speed up to 93 mp/h

ZK00573
251.

Order No.
US$

Mounting Hardware
(tubes vertical, angled)
for a free-standing, flat roof installation, mounted to substructure1
fixed collector angle 45 (non-adjustable)
snow loads up to 31.3 lb/ft2
wind speed up to 93 mp/h

ZK00574
251.

Order No.
US$

Mounting Hardware
(tubes vertical, angled)
for a free-standing, flat roof installation, mounted to substructure1
fixed collector angle 60 (non-adjustable)
snow loads up to 31.3 lb/ft2
wind speed up to 93 mp/h

ZK00575
251.

Order No.
US$

Mounting Hardware
(tubes vertical, angled)
for a free standing, flat roof installation, mounted to substructure1
Adjustable angle frames 25 to 50
snow loads up to 53.2 lb/ft2
wind speed up to 93 mp/h

7510 997
340.

Order No.
US$

Single Parts For Installation

Collector Absorber Area


13.56
1.26

Spare parts Set


assortment of spare parts which may get lost during installation.
1

32.61 ft2
3.03 m2

16.25
1.51
7514 876
15.60

32.61 ft2
3.03 m2
Order No.
US$

Substructural material (to which mounting rack is attached to) must be field supplied.

This trademark is registered with the U.S. Patent and Trademark Office.

91

Vitosol
200-T SP2A

Required hardware with corresponding


collector absorber area

VITOSOL 200-T
SP2A Series
Horizontal Mounting Accessories
Horizontal Mounting Accessories

Installation on sloped roofs


Required hardware with corresponding
collector absorber area

16.25
1.51

32.61 ft2
3.03 m2

ZK00583
250.

Mounting Hardware
(tubes horizontal)
for a sloped, shingled roof

Order No.
US$

Installation on wall/balcony
Required hardware with corresponding
collector absorber area
Mounting Hardware
(tubes horizontal)
for a wall/balcony installation

92

13.56
1.26

16.25
1.51
ZK00825
167.

32.61 ft2
3.03 m2
Order No.
US$

VITOSOL Installation
System Technology

Solar Supply/Return Piping Kit, 50 / 15m


set of 2 flexible stainless steel pipes, nominal diameter
set of 4 compression fittings, 22mm
set of 4 copper connectors 2 x 22mm
set of 4 pipe supports including attachment hardware
with weather proof, high temperature insulation
with sensor wire
with one roll of weather proof tape

7511 569
768.

Order No.
US$

Solar Supply/Return Piping Kit, 40 / 12m


set of 2 flexible stainless steel pipes, nominal diameter
set of 4 compression fittings, 22mm
set of 4 copper connectors 2 x 22mm
set of 4 pipe supports including attachment hardware
with weather proof, high temperature insulation
with sensor wire
with one roll of weather proof tape

7511 568
675.

Order No.
US$

Solar Supply/Return Piping Kit, 20 / 6m


set of 2 flexible stainless steel pipes, nominal diameter
set of 4 compression fittings, 22mm
set of 4 copper connectors 2 x 22mm
set of 4 pipe supports including attachment hardware
with weather proof, high temperature insulation
with sensor wire
with one roll of weather proof tape

7511 567
403.

Order No.
US$

Splice Fittings, 22mm (1 pair)


to connect two pieces of solar supply/return piping together

7817 370
44.

Order No.
US$

Compression Fittings, 22mm (1 pair)


to connect solar supply/return piping to the components of the solar system

7817 369
44.

Order No.
US$

Copper Adaptor (each)



length: 4, to adapt from 22mm to pipe

9543 380
11.70

Order No.
US$

Copper Connector (each)



length: 2, to interconnect 22mm componentry

5276 590
5.60

Order No.
US$

Other Accessories

This trademark is registered with the U.S. Patent and Trademark Office.

93

Vitosol
Installation

Flexible Insulated Piping Systems

VITOSOL Controls
System Technology

Solar System Controls

Solar Control Unit SCU 124


electronic differential temperature control with one differential setting:
illuminated digital readout (in F or C) with user-friendly menu operation
capable of managing one collector field and one DHW storage tank
2 control relay outputs, 4 sensor inputs, and 3 system configurations
communicates via VBus with optional equipment (below)
dimensions: W 41/4 x H 63/4 x D 13/4
Standard Equipment: Solar Control Unit SCU124 with 1 collector sensor, and 2 tank sensors

7439 303
315.

Order No.
US$

Solar Control Unit SCU 224


electronic differential temperature control with two differential settings:
illuminated digital readout (in F or C) with user-friendly menu operation
capable of managing two collector fields or two DHW storage tanks
2 control relay outputs, 4 sensor inputs, and 10 system configurations
communicates via VBus with optional equipment (below)
dimensions: W 41/4 x H 63/4 x D 13/4
Standard Equipment: Solar Control Unit SCU224 with 2 collector sensors, and 2 tank sensors

7439 304
426.

Order No.
US$

Solar Control Unit SCU 345


Electronic differential temperature control for multi-load systems:

large illuminated digital display (in F or C) with user-friendly menu operation

capable of managing 2 collector fields and up to 3 storage tanks

4 control relay outputs, 5 sensor inputs, 9 system configurations

freely adjustable Delta-T function and heat dump function

data logging onto internal SD card (card not included)

communication via VBus with optional equipment (below)

optional V40 Flowmeter Kit can be connected for energy metering
Standard Equipment: Solar Control Unit SCU345 with 2 collector sensors and 2 tank sensors

7511 929
475.

Order No.
US$

Solar Energy Meter SEM


Energy meter for recording energy produced by solar energy systems (kWH):

illuminated digital readout of temperatures and energy yield

communication via VBus to DL2 Datalogger

suited for systems with water/glycol mixture up to 70%

requires V40 Flowmeter Kit and 2 temperature sensors (order separately)
Standard Equipment: Solar Energy Meter SEM with UL-listed power plug

7511 930
334.

Order No.
US$

All products listed above are for indoor use only.

94

VITOSOL Controls
System Technology

Compatible with
SCU 124

SCU 224

SCU 345

7416 047
557.

Smart Display SD3


serves as a visualization of collector and DHW tank temperature,
as well as energy transfer (kWh) within the solar system
illuminated digital readout (in F and kWh)
VBus interface (for power and data)
for wall-mount or table-top use
dimensions: W 6 x H 61/2 x D 1

SEM

Model
No.

N/A

Order No.
US$

7416 049
503.

Datalogger DL2 with ServiceCenter Software


compact, wall mounted device to capture system operational details enabling
further analysis using ServiceCenter software, or using spreadsheet software
ability to read Datalogger using Ethernet cable directly connected to PC or
router
ability to change system settings of Solar Control Unit using PC and ServiceCenter software
VBus interface
dimensions: W 51/4 x H 51/2 x D 13/4
Standard Equipment: Datalogger DL2, ServiceCenter software,
6ft Ethernet cable, and 120V power supply

Order No.
US$

Flowmeter Kit, V40-06 rotary flowmeter for measuring the flow of solar fluid:

maximum flow: 3 USGPM

maximum temperature 250F
3/4 NPT connection fittings

Standard Equipment:
V40-06 Pulse Flowmeter with 2 temperature sensors, 2 sensor wells 1/2 NPT

N/A

N/A

7511 931
354.

Order No.
US$

Flowmeter Kit, V40-15 rotary flowmeter for measuring the flow of solar fluid:

maximum flow: 6 USGPM

maximum temperature 250F
3/4 NPT connection fittings

Standard Equipment:
V40-15 Pulse Flowmeter with 2 temperature sensors, 2 sensor wells 1/2 NPT

N/A

N/A

7511 932
354.

Order No.
US$

Flowmeter Kit, V40-25 rotary flowmeter for measuring the flow of solar fluid:

maximum flow: 10 USGPM

maximum temperature 250F
3/4 NPT connection fittings

Standard Equipment:
V40-25 Pulse Flowmeter with 2 temperature sensors, 2 sensor wells NPT

N/A

N/A

7511 933
354.

Order No.
US$

Strap-on Sensor, PT1000


for surface mounting on pipes with pipe clamp

7511 934
60.

Order No.
US$

Sensor Well, nickel plated copper construction


1/2 NPT thread


1.77

7511 935
29.

Order No.
US$

Interface Adaptor, VBus to USB (including software)


allows for connection to a personal computer to view system activities and
performance in real time obtained from the SCU or SEM and its sensors.
Standard Equipment: ServiceCenter Software CD, and 31 / 0.8m VBus/USB
adaptor cable

7416 050
242.

Order No.
US$

Interface Adaptor, VBus to PWM (0-10V)


to enable control to operate a high-efficiency pump.
Installed between the VBus output of the controller
and 0-10V input of pump

7511 936
185.

N/A

Order No.
US$

All products listed above are for indoor use only.


This trademark is registered with the U.S. Patent and Trademark Office.

95

Vitosol
Controls

Optional Equipment

VITOSOL Storage
System Technology

Vitocell 100

steel, with two-coat


enamel finish

CVA-53

CVA-79

CVA-119

7134 161
1,610.

7134 162
1,950.

ZK00427
2,345.

CVB-79

CVB-119

Model No.

7134 448 ZK00428


2,375.
3,431.

Order No.
US$

DHW tank to heat water for


domestic use in combination with
a solar system
CVA Series

Brass Elbow with sensor well for


tank temperature sensor
(for solar applications only)

7175 213
35.

CVB Series

7175 214
35.

included
above

included
above

Order No.
US$

EVB-119

Model No.

7134 383 ZK00432


3,615. 4,578.

Order No.
US$

7175 213 7219 729


35.
35.

Order No.
US$

Important: to maintain tank warranty on Vitocell 100 tanks, consumable anode


must be properly inspected and, where necessary, replaced every two years.

Vitocell 300
stainless steel

EVI-53

EVI-79

EVI-119

7134 381
2,209.

7134 382
2,786.

ZK00431
4,084.

EVB-79

DHW tank to heat water for


domestic use in combination with
a solar system
EVI Series

Brass Elbow with sensor well for


tank temperature sensor
(for solar applications only)

7175 213
35.

Important:
For multiple tank applications, please see Technical Data Manual.

96

7219 729
35.

EVB Series

VITOSOL Accessories
System Technology

Installation Accessories

Automatic Air Vent 1


with air separator, shut-off valve, and
22mm brass compression couplings
* Not required if using Solar-Divicon

7316 049
100.

Order No.
US$

Fast Air Vent 1


with shut-off valve, brass piping tee
and brass compression couplings ( 22mm)
for use in high point of collector array

7316 789
67.

Order No.
US$

Manual Air Vent 1


with manual key vent and brass
compression couplings ( 22mm)
for use in high point of collector array

7316 263
20.

Order No.
US$

Brass Elbow with sensor well


for installing solar tank temperature sensor

1
7175 213
35.

11/4
7219 729
35.

Dia
Order No.
US$

Solar Hand Pump


to fill and increase pressure

7188 624
121.

Mobile Solar Charge Station


to flush and fill glycol of solar systems
telescopic handle
120/1/60, 8 USG / 30L per min. pump
dirt filter on suction side
1 charge hose, 1 suction hose
8 USG / 30L storage tank for glycol

7497 469
904.

Net Price

4
18

6
25

10
40

13
50

21
80

7248 241
135.

7248 242
174.

7248 243
221.

7248 244
328.

7248 245
413.

Solar Expansion Tank 2


with mounting hardware including:
air bleed
shut-off valve

Order No.
US$
Order No.
US$

USG
ltr
Order No.
US$

Glycol Tester
for solar fill

7316 074
44.

Order No.
US$

Tyfocor-HTL Solar Fill


5.28 USG / 20 Ltr.
premixed for protection to -31F / -35C

7316 098
135.

Order No.
US$

Spare Parts Set


an assortment of small parts sometimes lost
during installation activities

Vitosol
100/200
7317 071
20._

Copper Adaptor (each)



length: 4, to adapt from 22mm to pipe

9543 380
11.70

Order No.
US$

Copper Connector (each)



length: 2, to interconnect 22mm componentry

5276 590
5.60

Order No.
US$

Lifting Harness for Vitosol-F


2 lifting rails c/w straps

7188 503
147.

1
2

Vitosol
300
7317 072
32.

SP2A

Vitosol SPE

7514 876
15.60

7507 763
5.40

Net Price

Series
Order No.
US$

Order No.
US$

Requires 2 x 9543 380 copper adaptors if ordered individually (and not with an installation fittings set.) List Price $11.70.
Requires 1 x 9516 310 brass coupling if ordered individually (and not with an installation fittings set.) List Price $17.70.

This trademark is registered with the U.S. Patent and Trademark Office.

97

Vitosol
Accessories

Compatibility
Vitocell-V / -B 100/300 up to 79 USG *
Vitocell-V / -B 100
119 USG *
Vitocell-V / -B 300
119 USG
* Standard equipment of Vitocell-B 100 (all sizes)

1
7175 214
35.

VITOSOL Divicon
System Technology

Preassembled Pumping Stations

Preassembled Solar Pumping Station with


everything required to pump solar fluid from a
collector array to a Vitocell internal coil storage
tank. Fast and easy to install with wall-mount
bracket. Attractive finished appearance
and safe, efficient and reliable operation.
Available in two sizes, for both residential and
light commercial applications.

Solar-Divicon

DN20

DN25

Model

7134 799
668.

7552 453
1,089.

Order No.
US$

Star
S16U-15

Star
S30U-25

System
Pump

Components included:
three-speed pump
system fill manifold
2 x thermometers / 2 x ball valves
2 x flow check valves in solar loop
pressure relief valve, 87 psig
pressure gage
flow meter
air separator
insulation cover

A Solar Collector
B Solar-Divicon
C Vitocell-V/B

DHW Storage Tank

98

DN20 dimensions:
H 21
W 111/2
D 6
Flex Pipe 20 x G
to connect Solar-Divicon
to expansion tank sizes
18, 25 or 40L only

DN25B dimensions:
H 181/4
W 12
D
7
7497 468
24.

Order No.
US$

VITOSOL Divicon
System Technology

Preassembled Pumping Stations

Preassembled Solar Heat-Transfer Station with


everything required to transfer solar heat from
a glycol collector loop to a DHW storage tank.
Fast and easy to install with wall-mount bracket.
Attractive finished appearance and safe,
efficient and reliable operation. Available in two
sizes, for both residential and light commercial
applications.

Solar-Divicon-HX

DN20

DN25

Model

7834 370
2,745.

7834 371
3,414.

Order No.
US$

Star
S21U-15

Star
S30U-25

Primary
Pump

Star
S21BU

Star
S21BU

Secondary
Pump

Components included:
pre-wired solar control c/w sensors
high efficiency double wall
stainless steel heat exchanger
three-speed pump for solar loop
three speed bronze pump for DHW loop
system fill manifold
2 x thermometers / 4 x ball valves
2 x flow check valves in solar loop
solar loop pressure relief valve, 87 psig
pressure gage
flow meter
air separator
insulation cover

B
C

Vitosol
Divicon

dimensions: H 25

W 12

D
9

A Solar Collector
B Solar-Divicon-HX
C DHW Storage Tank
(by others)

Flex Pipe 20 x G
to connect Solar-Divicon
to expansion tank sizes
18, 25 or 40L only

7497 468
24.

Order No.
US$

ffA pressure relief valve with a maximum pressure of 150 psig must be installed on the secondary DHW loop of the Solar-Divicon-HX.
For 150 psig, order optional pressure relief valve 9643 205, List Price $20.-.

This trademark is registered with the U.S. Patent and Trademark Office.

99

ESOP NA 4.0
Simulation Software

ESOP NA 4.0

interactive simulation program for the planning, design and optimization of Viessmann solar thermal systems

Product description
ESOP NA 4.0 is a solar simulation program designed to assist solar professionals with the planning and design
of Viessmann solar systems.
The program comes with 12 standard system configurations for solar DHW, combi DHW/space heating or
stand-alone pool heating systems, and includes climate data for locations across North America as well as
product specifications for all Viessmann solar collectors and DHW storage tanks.
ESOP operates with metric or imperial units and features an integrated Design Assistant to help users navigate
the program.
The installation file can be run as a demo version, which allows for review of the program prior to purchasing.
A serial number must be purchased to activate the full program.
How to order
1. Go to the Viessmann website 1 and download the installation file and serial number order form.
2. Fax serial number order form to Viessmann, complete with e-mail address and major credit card or
purchase order information (customer must have an existing account with Viessmann to use a PO).
3. Obtain activation serial number via e-mail or fax within 2 business days.

Minimum system requirements

Processor:

1 GHz

Memory:

512 MB

HD Free Space:

400 MB

Screen Resolution:

Minimal resolution: 1024 x 768

Operating System:

Windows 2000, XP, Vista, 7

www.viessmann.ca/esop

100

7248 265 Order No.


128. US$
Net Price

VITOROND 200
Triple-pass hot water heating boiler
490 to 1096 MBH / 144 to 321 kW

Vitorond 200
VD2A Series
Oil-/Gas-Fired Boiler
sectional cast iron design
with Eutectoplex heat transfer surface, in triple-pass design
for operation with modulating water temperatures
Heating input: 490 to 1096 MBH

144 to 321 kW

This trademark is registered with the U.S. Patent and Trademark Office.

Eutectoplex heat transfer surface for high operational reliability


and a long service life. The homogeneous structure of the
Eutectoplex special gray cast iron provides uniform heat transfer,
minimizing stress fractures.
Problem-free transport into difficult-to-access boiler rooms due
to sectional construction and the low weight of individual
sections.
Low-emission combustion due to the triple-pass design.
Efficient and environmentally friendly operation due to
modulated boiler water temperatures.
Simple, quick assembly of the individual cast iron sections is
achieved with a double-groove seal fit system for the flue gas
passageways. The gasket seal is secured in place by the double
groove, therefore not subject to mechanical stresses.
Problem-free cleaning access facilitated by a hinged (left or
right), swing-open combustion chamber door providing easy
access to all three heat exchanger passes from boiler front,
reducing side clearance.

101

Vitorond
200

Boiler control and burner may not be exactly as illustrated.

VITOROND 200

Vitorond 200
VD2A125 VD2A160 VD2A195 VD2A230 VD2A270

Boiler

Input - oil
Input - gas
Output - oil/gas

490
508
433

628
650
553

765
792
672

902
934
794

1059
1096
932

Model
No.
MBH
MBH
MBH

Vitorond 200 boilers, controls, and burners are priced on a quotation basis only due to
the varying application requirements. Please contact your local Viessmann Sales
Representative - see listing at rear of Price List.

List Price

Vitorond 200 boilers require start-up by Viessmann Factory Trained Personnel.


Start-up costs will be included in your quotation (mentioned above).
Control
Vitotronic 100 or Vitotronic 300

Other Required
Equipment

Burner
Weishaupt or Riello c/w gas train (if applicable)

Technical Data
Overall
Dimensions

Length
Width
Height

Boiler Water Content

35
905
34
860
39
1007

42
1075
34
860
39
1007

49
1240
34
860
39
1007

55
1410
34
860
39
1007

62
1580
34
860
39
1007

32
122

41
154

49
186

57
217

66
249

Boiler Vent Connection


Weight (Shipping)

1201
545

1441
655

inches
mm
inches
mm
inches
mm
USG
ltr
inches

1675
760

1874
850

2127
965

lbs
kg

Weishaupt Burner
WL20

WL30

Model
No.

No. 2 oil-fired

2-stage

Natural gasfired

2-stage/full
mod

WG20

WG30

Model
No.

Propane-fired

2-stage/full
mod

WG20

WG30

Model
No.

Riello Burner
No. 2 oil-fired
Natural gas-fired
Natural gas-fired full mod.

F15

F20
G750

N/A

G900

N/A

RL28/2

Model
No.

N/A

Model
No.

RS28/M

Model
No.

ffBoiler maximum working pressure: 85 psig


Standard Equipment: includes supply and return header, low water cut-off, thermometer, pressure gage, air vent,
85 psig pressure relief valve, boiler drain valve, and cleaning brush.

102

VITOROND 200
Triple-pass hot water heating boiler
1255 to 4387 MBH / 368 to 1285 kW

Vitorond 200
VD2 Series
Oil-/Gas-Fired Boiler
sectional cast iron design
with Eutectoplex heat transfer surface, in triple-pass design
for operation with modulating water temperatures
Heating input: 1255 to 4387 MBH

368 to 1285 kW

This trademark is registered with the U.S. Patent and Trademark Office.

Eutectoplex heat transfer surface for high operational reliability


and a long service life. The homogeneous structure of the
Eutectoplex special gray cast iron provides uniform heat transfer,
minimizing stress fractures.
Problem-free transport into difficult-to-access boiler rooms due
to sectional construction and the low weight of individual
sections.
Low-emission combustion due to the triple-pass design.
Efficient and environmentally friendly operation due to
modulated boiler water temperatures.
Simple, quick assembly of the individual cast iron sections is
achieved with a double-groove seal fit system for the flue gas
passageways. The gasket seal is secured in place by the double
groove, therefore not subject to mechanical stresses.
Problem-free cleaning access facilitated by a hinged (left or
right), swing-open combustion chamber door providing easy
access to all three heat exchanger passes from boiler front,
reducing side clearance.

103

Vitorond
200

Boiler control may not be exactly as illustrated.

VITOROND 200

Vitorond 200

Boiler

Input - oil
Input - gas
Output - oil/gas

VD2
320

VD2
380

VD2
440

VD2
500

VD2
560

VD2
630

VD2
700

VD2
780

VD2
860

VD2
950

VD2 Model
1080 No.

1255
1300
1110

1490
1544
1319

1726
1787
1526

1961
2031
1732

2196
2275
1941

2471
2559
2183

2745
2843
2425

3059
3168
2699

3373
3493
2976

3727
3860
3135

4236 MBH
4387 MBH
3738 MBH

List Price

Vitorond 200 boilers, controls, and burners are priced on a quotation basis only due to the
varying application requirements. Please contact your local Viessmann Sales Representative see listing at rear of Price List.
Vitorond 200 boilers require start-up by Viessmann Factory Trained Personnel.
Start-up costs will be included in your quotation (mentioned above).

Other Required
Equipment

Control
Vitotronic 100 or Vitotronic 300
Burner
Weishaupt or Riello c/w gas train (if applicable)
Low Temperature Protection Package

Technical Data
Overall Dimensions
Total Length
Total Width
Total Height

Boiler Water Content

58
1490
49
1250
50
1290

63
1620
49
1250
50
1290

68
1750
49
1250
50
1290

73
1870
49
1250
50
1290

78
2000
49
1250
50
1290

83
2130
49
1250
50
1290

89
2260
49
1250
50
1290

93
2380
49
1250
50
1290

98
2510
49
1250
50
1290

104
2640
49
1250
50
1290

65
247

73
275

80
303

87
331

95
359

102
387

110
415

117
443

124
471

132
499

3924
1780

4299
1950

4652
2110

4982
2260

5335
2420

inches
mm
inches
mm
inches
mm

139 USG
527 ltr

12

Boiler Vent Connection


Weight (Shipping)

108
2760
49
1250
50
1290

inches
5666
2570

6019
2730

6349
2880

6702
3040

7070
3210

7429 lbs
3370 kg

Weishaupt
No. 2 oil-fired

2-stage

WL40

Natural gasfired

full mod

WG40-LN

Combination full mod NG/


oil

WM-L10/3
WM-G10/3-LN

Combination full mod NG/


LP

WM-L10/4
WM-G10/4
RGL5

WM-G10/2

L7

WM-G10/3

Model
No.
G7-LN

Model
No.

RGL7

Model
No.

WM-G10/4

Model
No.

Riello
No. 2 oil-fired 2-stage/ full mod

RL28

RL38

RL50

RL70

Natural gasfired

full mod

RS38/M

RS50/M

RS70/M

Combination

2-st NG/oil

RLS38

RLS50

RLS70

RL100
RS100/M
RLS100

ffBoiler maximum working pressure: 75 psig


Standard Equipment: includes supply and return header, low water cut-off, thermometer, pressure gage, air vent,
75 psig pressure relief valve, boiler drain valve, and cleaning brush.

104

Model
No.
Model
No.
RLS130 Model
No.

VITOCROSSAL 300

Vitocrossal 300
CT3 Series
High efficiency, gas-fired condensing boiler
with Inox-Crossal heat exchanger surfaces
of corrosion-resistant stainless steel
Heating input: 638 to 3361 MBH

187 to 985 kW

This trademark is registered with the U.S. Patent and Trademark Office.

Inox-Crossal heat transfer surface - vertically oriented, of


corrosion-resistant stainless steel - for high operational reliability and
a long service life.
Low-emission combustion - with emission values within and well
below the limits set by the requirements of the German environmental
emblem "Blue Angel", the Swiss Clean Air Regulations, and the new
environmental performance guideline for boiler emissions established by
the CCME, effective 1994.
The new, highly efficient Inox-Crossal heating surfaces ensure optimum
heat transfer to the boiler water.
Easy transport into boiler rooms due to narrow design and low weight
- an important factor in modernizing the boiler room.
Safe heat transfer ensured by wide dimension water walls and large
water content.

105

Vitocrossal
300

High efficiency, gas-fired condensing boiler


638 to 3361 MBH / 187 to 985 kW

VITOCROSSAL 300

Vitocrossal 300

Boiler

Input

CT3-17

CT3-22

CT3-28

CT3-37

CT3-46

CT3-57

CT3-72

638

846

1071

1389

1726

2160

2702

CT3-89

Model
No.

3361 MBH

Vitocrossal 300 boilers, controls, and burners are priced on a quotation basis only due
to the varying application requirements. Please contact your local Viessmann Sales
Representative - see listing at rear of Price List.

List Price

Vitocrossal 300 boilers require start-up by Viessmann Factory Trained Personnel.


Start-up costs will be included in your quotation (mentioned above).
Other Required Equipment

Control
Vitotronic 100 or Vitotronic 300
Burner 1
Weishaupt and Riello prewired by Viessmann to integrate with control
Gas train in the range of 4" w.c. to 5 psig
Approval: CSA/UL; others available, please inquire
Custom Stainless Steel Chimney System
Supplied by Viessmann

Technical Data
Overall Dimensions
Depth
Width
Height
Boiler Water Content

64
1636
40
1016
797/8
2027

67
1714
40
1016
811/8
2009

70
1795
40
1016
81
2065

73
1871
44
1132
935/16
2370

76
1949
44
1132
935/16
2370

83
2105
44
1132
935/16
2370

85
2172
49
1249
101
2585

93
2366
49
1249
101
2585

71.3
270

78.2
296

87.2
330

129.5
490

140.8
533

150.6
570

199.2
754

221.9 USG
840 ltr

Boiler Vent Connection


Weight (Shipping)
with jacket, without burner

1228
557

10

1352
613

1455
660

1962
890

2064
936

12
2322
1053

3014
1370

inches
mm
inches
mm
inches
mm

inches
3344 lbs
1520 kg

Weishaupt Burner
Natural gasfired

2-stage

WG20-LN

WG30-LN

WG40-LN

WM-G10/3-LN WM-G10/4 Model


No.

Natural gasfired

full mod.

WG20-LN

WG30-LN

WG40-LN

WM-G10/3-LN WM-G10/4 Model


No.

Riello Burner
Natural gas-fired
Propane gas-fired

G750

G900

RS28/M

RS38/M

RS50/M

RS70/M

RS100/M Model
No.

RS28/M

RS38/M

RS50/M

RS70/M

RS100/M Model
No.

All Weishaupt burners are sold with a low NOX burner head.
ffBoiler maximum working pressure: 30 psig
Standard Equipment: includes low water cut-off, safety header
(c/w 30 psig pressure relief valve, air vent and pressure gage), and drain valve

106

KB Wood-Fired Systems
512 to 4268 MBH

Pyrot

Pyrotec

Pyrotec KPT

Boiler with automatic


fuel feed system

Full-automatic, state-of-the-art underfeed


combustion wood-fired boiler

Supply temperatures of up to 212F / 100C

Supply temperatures of up to 212F / 100C

Available for 30 psig or 60 psig maximum operating pressure

Available for 30 psig or 60 psig maximum operating pressure

ASME construction

ASME construction

Fuel types: 0.2" / 6mm pellets, industrial pellets, forest wood


chips, wood cut-offs, briquettes from off-cuts

Fuel types: 0.2" / 6mm pellets, industrial pellets, forest wood


chips, wood-cut-offs, briquettes from off-cuts

For wood fuels with a maximum water content of 35%

For wood fuels with a maximum water content of 50%

5 models from 512 to 1843 MBH

5 models from 1330 to 4268 MBH

KOB

Pyrot KRT

This trademark is registered with the U.S. Patent and Trademark Office.

107

KB Wood-Fired Systems

Pyrot
Pyrot
150

Pyrot
220

Pyrot
300

Pyrot
400

512
150

751
220

1024
300

1365
400

Pyrot
540

Model No.

Pyrot
Output

1843 MBH
540 kW

Pyrot boilers are priced on a quotation basis only due


to the varying application requirements.
Please contact Viessmann.

List Price

Order No.

Technical Data

Overall Dimensions

Length
Width
Height

Weight
boiler only (dry)

99
2513
41
1050
71
1825

100
2537
52
1330
82
2084

114
2893
52
1330
82
2084

113
2877
61
1570
95
2422

122
3105
61
1570
98
2492

inches
mm
inches
mm
inches
mm

4846
2198

6667
3024

7568
3433

9784
4438

11261
5108

lbs
kg

10

Boiler Vent Connection

12

14

inches

Pyrotec
Pyrotec
390

Pyrotec
530

Pyrotec
720

Pyrotec
950

1330
390

1809
530

2457
720

3242
950

Pyrotec Model No.


1250

Pyrotec
Output

4268
1250

Pyrotec boilers are priced on a quotation basis only


due to the varying application requirements.
Please contact Viessmann.

List Price

MBH
kW
Order No.

Technical Data
Important!
Overall Dimensions

Length
Width
Height

Weight
boiler only (dry)
Boiler Vent Connection

108

129
3282
50
1274
93
2378

149
3782
50
1274
100
2536

152
3877
54
1380
111
2834

151
3835
63
1612
119
3035

172
4380
63
1612
127
3230

11530
5230

16654
7554

19553
8869

25272
11463

28479
12918

14

16

inches
mm
inches
mm
inches
mm
lbs
kg
inches

NOTES

[
This trademark is registered with the U.S. Patent and Trademark Office.

109

NOTES

110

Terms and Conditions of Sale, Delivery and Payment


Viessmann
Appendix 1

2. For all Viessmann biomass projects, payment terms shall be thirty


I. General Provisions
1. This agreement, performances of contract and quotations are made percent (30%) of the total contract price as a down payment at the
exclusively upon the terms and conditions set out below. Alterations time of the purchase order and seventy percent (70%) due on receipt
or deviations from the provisions herein contained shall not be binding of products, including partial shipments. All payments shall be made
by telegraphic transfer.
upon Viessmann unless confirmed in writing by Viessmann.
3. Holdbacks or deductions of any kind whatsoever without prior written
2. The Purchaser hereby accepts the terms and conditions herein
authorization from Viessmann are expressly prohibited.
contained in their entirety. Stipulations of terms and conditions
4. Discounts, if any, shall be calculated on the cost of goods as per
contrary to the provisions hereof according to the Purchasers
invoice, exclusive of cost of packaging, crating, freight or shipping,
business or purchasing practices, invoicing, manner of payment or
custom of the trade are hereby specifically agreed to be inapplicable federal, provincial, state or local rates, tariffs or taxes, where
applicable, or other costs or surcharges beyond control of Viessmann.
to this agreement.
3. In the event that any one or more of the provisions herein contained 5. Payment by bank draft, money order or uncertified cheque may be
shall become or be deemed to be invalid, illegal or unenforceable by made only with the express written consent of Viessmann. All costs
for dishonor, presentment for payment or collection shall be at the
operation of law, the validity, legality and enforceability of the
expense of the Purchaser and Payer. All payments by cheque,
remaining provisions or any part thereof shall not in any manner be
affected or impaired thereby. In place and instead of any such invalid, whether certified or uncertified, shall be deemed as having been
received on the date of acceptance for payment of the said cheque or
illegal or unenforceable provisions or any part thereof, the parties
cheques by the Purchasers or Payers bank, trust company or
hereto shall be deemed to have agreed upon terms and conditions,
which, as far as permitted by law, express the intent and purpose of financial institution upon whose account the cheque has been issued.
6. Payments received shall be applied firstly to the oldest costs for
the within terms and conditions.
4. Any product purchased from Viessmann in the United States is for presentment for payment, dishonor or collection; secondly, to
resale and use only in the United States. Purchasers agree that they outstanding interest charges on the oldest accounts; and thirdly, the
will not resell Viessmann products for use or installation outside of the balance, if any, of any payment shall be applied to the oldest
outstanding balance or balances.
United States and will take all reasonable and necessary steps to
ensure that the Viessmann products they purchase are resold only for 7. In the event the Purchaser defaults in payment or causes a cheque,
bank draft or money order to be dishonored or stops payment thereon,
use and installation in the United States.
or Viessmann shall deem the Purchaser insecure, all accounts shall
II. Plans and Specifications
forthwith become due and payable notwithstanding any agreement as
1. Drawings, specifications and technical data appended to or forming
to credit or periodic payment.
part of this agreement shall at all times remain the property of
8. Overdue accounts shall bear interest at the rate stated on the face of
Viessmann, with all rights reserved and shall not be provided,
the invoice but in no event less than five percent (5%) above prime
submitted or disclosed to third parties without the express written
rate of interest set from time to time by the Federal Reserve
consent of Viessmann. Changes, alterations, deletions or additions
for purchases in the USA and shall be calculated weekly and
thereto shall not be binding upon Viessmann unless confirmed in
compounded monthly.
writing by Viessmann.
V. Reservation of Title and Property
III. Prices and Quotations
1. It is hereby expressly agreed that all goods shall remain the exclusive
1. Viessmann hereby specifically reserves the right to change, alter,
property of Viessmann and title shall not pass until payment in full of
amend or revoke quotations and the same shall become binding and
all invoices or accounts rendered, including cost of goods, packaging,
irrevocable only upon written acceptance by both Viessmann and the
crating, shipping or freight charges, federal, provincial, state or local
Purchaser or upon delivery and acceptance of goods or performance
taxes, rates and tariffs, insurance, extras to contract, interest
of work or services by Viessmann.
charges, exchange or collection expenses and other sums or charges
2. Prices are, save and except as otherwise agreed upon, as of
applicable has been received pursuant to the terms and conditions
Viessmann Manufacturing Company (U.S.) Inc., Warwick, Rhode Island
herein contained.
exclusive of cost of packaging, crating, freight or shipping, federal,
2. Goods delivered shall not, in any event, become part of real estate
state or local taxes in effect on date of delivery.
and the Purchaser shall at all times take or initiate all steps necessary
3. All contract prices are guaranteed for thirty (30) days from date of
to preserve the right of Viessmann to title to and property of such
contract. Cost increases thirty days after contract date, including, but
goods.
not limited to, cost increases of materials, wages, fuel, transportation
3. The Purchaser shall not permit any goods sold or delivered by
or energy charges and increases in applicable federal, provincial, state
Viessmann to be pledged or encumbered without express written
and local rates, tariffs or taxes shall be added to contract price and
consent from Viessmann. In the event of seizure by third parties, the
form part thereof as if originally agreed upon.
Purchaser shall forthwith disclose the reservation of title, right and
4. Contracts for delivery of goods or performance of services without
property by Viessmann to such goods and shall forthwith notify
specific agreement as to price shall be subject to the price or prices in
Viessmann of such seizure and shall assist Viessmann at the
effect on the date of delivery of goods or commencement of
Purchasers cost in the preservation and enforcement of the right of
performance of service.
Viessmann to title and property to the said goods.
IV. Terms of Payment
4. In the event of breach of contract by the Purchaser of the terms or
1. For all Viessmann products other than products for any biomass
conditions herein contained and in particular, default of payment of
project and save and except as otherwise specifically agreed upon in invoices as hereinbefore provided, Viessmann shall be entitled,
writing, all invoices or accounts, as the case may be, shall become
without prior notice, to demand delivery up of goods sold and
due and payable in full without deduction whatsoever thirty (30) days delivered and to seize the same wherever the same may be located at
after invoice date or account date.
any time of day or night or to cause its agents, workmen or bailiffs to

This trademark is registered with the U.S. Patent and Trademark Office.

111

Terms and Conditions of Sale, Delivery and Payment


Viessmann
Appendix 1

seize the same, wherever the same may be located at any time of day
or night notwithstanding the goods may be in possession of a
subsequent purchaser or user.
5. Seizure of goods by Viessmann shall not be deemed to constitute
termination of contract or contractual rights and obligations as
between Viessmann and the Purchaser.
VI. Delivery of Goods
1. Viessmann shall at all times use its best efforts to maintain delivery
dates agreed upon. The delivery date or period shall be deemed to
have been maintained or complied with in all events, cases or
situations where the goods to be delivered leave the premises of
Viessmann on or before such date or expiry of such period or upon
notification to the Purchaser that the goods are ready for shipment.
2. Delivery dates or periods shall be extended by reason of delays
caused by labor shortages, strikes or lockouts or other circumstances
beyond the reasonable control of Viessmann. Any delay or
postponement of delivery to Viessmann of goods and supplies by its
suppliers, subcontractors or co-contractors caused by strike, lockout,
labor shortage or unrest or other causes beyond the reasonable
control of Viessmann, its suppliers, subcontractors or co-contractors
shall in like manner extend delivery dates and periods as if the same
applied to Viessmann.
3. In the event of delay of delivery of goods caused by the Purchaser
for any reason whatsoever Viessmann shall be entitled to charge
the cost of storage calculated at the rate of one half percent (0.5%)
per month upon the cost of goods, such calculation commencing
one month after delivery of Notice of Readiness for shipment and
continuing for each and every month or part thereof thereafter until the
delivery of goods to the Purchaser.
VII. Risk of Property
1. Commencing on the date of delivery of goods for shipment or
transport to the Purchaser, the said goods or any part thereof shall be
at the risk of the Purchaser.
2. Deficiencies or defects in goods or part thereof shipped or shipment
of wrong goods or part thereof shall be endorsed upon the bill of lading
and shall be communicated to Viessmann in writing within eight (8)
days upon arrival at destination. Failing such notification the Purchaser
shall be deemed to have accepted the goods without recourse.
VIII. Return of Goods and Cancellations
1. All or any goods returned without prior written authorization by
Viessmann shall not be accepted.
2. If returns are authorized by Viessmann, goods will be accepted as
follows:
(i) Customer must provide proof of purchase, invoice and/or serial
number to receive a Return Goods Authorization number from
Viessmann. Upon authorization from Viessmann, freight will be
prepaid by the customer.
(ii) Products in the biomass price list upon forfeiting the down
payment or thirty percent (30%) of the project price within the first
five (5) weeks from the date of the purchase order. In case any
items have been shipped, freight has to be prepaid. Orders for
products in the biomass price list may not be cancelled after five
(5) weeks from the date of purchase order.
(iii) Item and packaging must be new and in saleable condition.
Twenty-five percent (25%) restocking charge on product returned
after 30 days of purchase.
(iv) Electronic parts, where factory seal has been broken are
not returnable.
(v) Discontinued products and/or parts are not returnable.

112

IX.Warranties
1. VIESSMANN MAKES NO WARRANTIES OR GUARANTEES, EXPRESS
OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY
OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR
PURPOSE, FOR THE GOODS SOLD OR DELIVERED OR SERVICES
PERFORMED UNDER OR PURSUANT TO THE PRECEDING TERMS
AND CONDITIONS.
No implied warranty arising by usage or custom or course of dealing
or course of performance is given by Viessmann or shall arise by or in
connection with the preceding terms and conditions, except those
express warranties set forth in writing and delivered with the goods.
2. The obligations of Viessmann with respect to any goods delivered or
services performed for any Purchaser under the terms and conditions
herein contained are limited exclusively to the repair, replacement or
refund of purchase price or cost of service at the sole discretion of
Viessmann. The remedies provided pursuant to the terms and
conditions herein contained shall be the exclusive remedies for the
Purchaser. Viessmann shall not be responsible for any special,
indirect, incidental or consequential damages caused by the goods
delivered or services performed pursuant to the terms and conditions
hereof.
X. Insurance
1. During the period commencing with the delivery of goods for shipment
or transport to the Purchaser and ending upon receipt of payment in
full for the said goods pursuant to the terms and conditions hereof the
Purchaser shall insure the said goods in the joint names of Viessmann
and the Purchaser against all risk of loss or damage howsoever
caused.
XI. Applicable Law
1. All disputes, claims or demands arising from or relating to warranties,
guarantees, representations authorized and published by Viessmann,
and from the terms and conditions herein contained and all claims,
demands, rights or liabilities arising from such warranties, guarantees,
representations or terms and conditions shall be determined in
accordance with the laws of the State of Rhode Island.
2. All proceedings based upon or arising out of the provisions of this
agreement shall be brought before the state or federal courts of the
State of Rhode Island, which shall have exclusive jurisdiction over
all such disputes. The parties waive any objections to venue in,
or the exercise of jurisdiction by, the state and federal courts in
Rhode Island.

Venting Categories
for Gas-Fired Boilers

Venting Categories

Product
Vitorond 100 1
VR1 Series

Classification

Draft Type

Minimum Material Requirement

Category I

Negative draft,
Non-condensing

B-Vent or equivalent

Category IV

Positive draft,
Condensing

Coaxial or PP(s) venting certified to ULC S-636

Vitorond 200 1
VD2A Series
VD2 Series

Vitodens 100-W
WB1B Series

Stainless steel venting


Vitodens 200-W
B2HA/B2HB
Series

CPVC venting certified to ULC S-636

Vitodens 222-F
B2TA/B2TB
Series
Vitocrossal 200
CM2 Series

Category IV

Positive draft,
Condensing

PP(s) venting certified to ULC S-636


Stainless steel venting
certified to ULC S-636 or UL 1738

Vitocrossal 300
CT3 Series

Category IV

Positive draft,
Condensing

Stainless steel venting


certified to ULC S-636 or UL 1738

Barometric damper must be used.

This trademark is registered with the U.S. Patent and Trademark Office.

113

Viessmann Warranties

Warranties

Product

Type

Residential Use

Commercial Use

Vitola 200

Steel boilers

Limited 20 years for pressure vessel.


Limited 2 years on boiler enclosure,
combustion chamber, controls and
accessories.

Limited 10 years for pressure vessel.


Limited 2 years on boiler enclosure,
combustion chamber, controls and
accessories.

See detailed warranty sheet 5348 721.

See detailed warranty sheet 5348 722.

Vitogas 050
Vitogas 100
Vitorond 100
Vitorond 200

Cast iron boilers

Limited 20 years for cast iron sections.


Limited 2 years on boiler enclosure,
combustion chamber, burner, controls and
accessories.

Limited 10 years for cast iron sections.


Limited 2 years on boiler enclosure,
combustion chamber, burner, controls and
accessories.

See detailed warranty sheet 5348 719.

See detailed warranty sheet 5348 720.

Wall-mounted,
condensing
stainless steel
boilers

Limited lifetime for pressure vessel.


Limited 2 years on boiler enclosure, burner,
controls and accessories.

Limited 10 years for pressure vessel.


Limited 2 years on boiler enclosure, burner,
controls and accessories.

See detailed warranty sheet 5348 723.

See detailed warranty sheet 5348 723.

Condensing
stainless steel
boilers

Limited 10 years for pressure vessel.


Limited 2 years on boiler enclosure, burner,
controls and accessories.

Limited 10 years for pressure vessel.


Limited 2 years on boiler enclosure, burner,
controls and accessories.

See detailed warranty sheet 5619 401.

See detailed warranty sheet 5619 401.

Limited 8 years for pressure vessel.


Limited 2 years on boiler enclosure, burner,
controls and accessories.

Limited 8 years for pressure vessel.


Limited 2 years on boiler enclosure, burner,
controls and accessories.

See detailed warranty sheet 5348 724.

See detailed warranty sheet 5348 724.


Limited 3 years for heat exchanger coil and
tank.
Limited 2 years on insulation jacket, controls
and accessories.

Vitodens 100-W
Vitodens 200-W
Vitodens 222-F
boiler only
Vitocrossal 200

Vitocrossal 300

Condensing
stainless steel
boilers

Vitocell 100

Ceraprotect-lined
indirect-fired
domestic hot
water tanks

Limited 8 years for heat exchanger coil and


tank.
Limited 2 years on insulation jacket, controls
and accessories.
See detailed warranty sheet 5348 725.

See detailed warranty sheet 5348 725.

Vitocell 300

Stainless steel
indirect-fired
domestic hot
water tanks

Lifetime for heat exchanger coil and tank to


original owner and installation site.
Limited 2 years on insulation, jacket, controls
and accessories.

Limited 8 years for heat exchanger coil and


tank.
Limited 2 years on insulation, jacket, controls
and accessories.

See detailed warranty sheet 5348 726.

See detailed warranty sheet 5348 726.


Limited 10 years for solar collectors.
Limited 2 years on controls and accessories.

Vitodens 222-F
DHW vessel
only
Vitosol

Solar heating
systems

Limited 10 years for solar collectors.


Limited 2 years on controls and accessories.
See detailed warranty sheet 5348 728.

See detailed warranty sheet 5348 728.

Pyrot
Pyrotec

Biomass boilers

Limited 5 years for pressure vessel.


Limited 2 years on boiler enclosure,
combustion chamber, controls and
accessories.

Limited 5 years for pressure vessel.


Limited 2 years on boiler enclosure,
combustion chamber, controls and
accessories.

See detailed warranty sheet 5367 500.

See detailed warranty sheet 5367 500.

114

Approval and Listing Overview


as of September 1, 2014
Viessmann

ASME H
Boiler and pressure vessel
built to ASME Sec. IV.
American Society of
Mechanical Engineers.
Applicable in Canada
and USA.

AHRI
Air Conditioning, Heating
and Refrigeration Institute
Listing is issued for gas- and oil-fired
boilers rated < 300 MBH which
have AFUE values (residential), and also
for units > 300 MBH which have combustion efficiency ratings (commercial).
Applicable in Canada and USA.

Energy Star
Logo Listing.
Issued for oil and gas
boilers with < 300 MBH only.
Applicable in Canada and USA.

CRN
Canadian Registration Number approval.
Issued for Canadian products complying
with CSA-B51 standard and the respective
Provincial Boiler and Pressure Vessel Act.
Acceptance in all provinces is indicated
with a C.
Applicable in Canada only.

NY
New York City approval.
Bureau of Air Resources (BAR) for oil
boilers greater than 20 GPH.
Applicable in NY City only.

Energy Verification
Logo Listing.
Issued for products with
< 300 MBH.
Applicable in Canada only.

CSA
Canadian Standards
Association approval.
Tests products for
compliance to Canadian
and American codes and standards.
Applicable in Canada and USA.

MASS
Massachusetts State approval.
Applicable to gas-fired boilers and
indirect-fired domestic hot water tanks
only.
Applicable in Massachusetts only.

SRCC Certification
Solar Rating and Certification
Corporation has certified
Vitosol 200-F SV2, SH2,
and Vitosol 300-T SP3.
Applicable in USA only.

EcoLogo
Third-party certification
of environmentallypreferable products.
Applicable in Canada and USA.

CEC
California Energy Commission listing.
Applicable in California only.

FSEC
Florida Solar Energy Center
Listing.
Issued for solar collectors and systems.
Applicable in Florida only.

CSA
CSA Low Lead Content
Certification Program
including US Safe Drinking
Water Act, NSF/ANSI 372
LOW LEAD
CONTENT
as well as other US State
requirements.
Applicable in Canada and USA.

This trademark is registered with the U.S. Patent and Trademark Office.

115

Approval and Listing Overview


as of September 1, 2014

Free-Standing Boilers
Oil-/Gas-Fired Heating Boilers

Sectional
cast iron boilers

Vitorond 100
VR1

CSA

CRN

AHRI

below

Eco-Logo

L6792.513467890YT2

NY

MASS

CEC

ASME

below

exempt

CEC

ASME

Ener
Star

Ener
Verif.

Ener
Star

Ener
Verif.

MEA# 15-01-E

Wall-Mount Boilers
Gas-Fired Condensing Boilers

Vitodens 100-W
WB1B

CSA

CRN

AHRI

Eco-Logo

below

WB1B

NY

MASS

8066.71234890YTN

Low lead applies to CombiPLUS DHW heater only.

Vitodens 200-W
B2HA/B2HB

B2HA 19
B2HA 28
B2HA 35
B2HA 45
B2HA 60
B2HA 80
B2HA 100
B2HA 112
B2HA 150

Vitodens 222-F
B2TA/B2TB

B2TA 19
B2TA 35

116

1831.98TN; T4480.4
1831.98TN; T4480.4
1831.98TN; T4480.4
8093.71234890YTN
8093.71234890YTN
8094.71234890YTN
8094.71234890YTN
M10020.513467YTN; W2847.2
M10020.513467YTN; W2847.2

1831.98TN; T4480.4
1831.98TN; T4480.4

B2HB 19
B2HB 26
B2HB 35

1831.98TN; T4480.4
1831.98TN; T4480.4
1831.98TN; T4480.4

B2TB 19
B2TB 35

1859.98TN
1859.98TN

Approval and Listing Overview


as of September 1, 2014

Indirect-Fired Domestic
Hot Water Storage Tanks

Vitocell 300-H

CSA

CRN

below

ETL

EcoLogo

NY

MASS

below

53USG/200L 5073.71
92USG/350L 5074.71
119USG/450L 5075.71, C8324.6

exempt

exempt

Vitocell 100-B

none

exempt

Vitocell 300-V

below

below

Vitocell 300-B

none

exempt

This trademark is registered with the U.S. Patent and Trademark Office.

F9181.17
F9182.17
F9183.17
F9184.1567T

ASME Ener
Star

Ener
Verif.

MEA# 71-90-E

Vitocell 100-V

42USG/160L
53USG/200L
79USG/300L
119USG/450L

CEC

MEA# 71-90-E

117

Approval and Listing Overview


as of September 1, 2014

Solar Systems
Solar Collectors

Vitosol 100-F
SV1B

SRCC

FSEC

208N

208N

Vitosol 200-F
SV2C
SV1B
SV2A
SV2C

Vitosol 100-F
SH1B

2007042A
2011023A
TBA
208N

208N

Vitosol 200-F
SH2C
SH1B
SH2A
SH2C

2007042A
2011023A
TBA

Vitosol 200-T
SPE
SPE 1.63 certification pending
SPE 3.26 certification pending

Vitosol 200-T
SP2A
SP2A 1.26 10001883
SP2A 1.51 10001882
SP2A 3.03 10001881

Free-Standing Boilers
Oil-/Gas-Fired Heating Boilers

Sectional
cast iron boilers

Vitorond 200
VD2A

CSA

CRN

AHRI

below

VD2A 125-270
CRN# M4977.5C

Vitorond 200
VD2

below

VD2 320-1080
CRN# M0255.5C

118

EcoLogo

NY

MASS

CEC

ASME Ener
Star

below

MEA# 70-90-E Vol. II

below

MEA# 302-96-E
BAR Approved

Ener
Verif.

Approval and Listing Overview


as of September 1, 2014

Free-Standing Boilers
Gas-Fired Condensing Boilers

Vitocrossal 200
CM2

CSA

CRN

AHRI

EcoLogo

below

CM2 186
CM2 246
CM2 311
CM2 186
CM2 246
CM2 311

Vitocrossal 200
CM2

NY

MASS

CEC

ASME

Ener
Star

Ener
Verif.

M8636.512346
M8634.512346
M8628.5C
M10202.51346
M10203.51346
M10204.51346
below

CM2 400 M9971.51346


CM2 500 M9973.51346
CM2 620 M9972.51346

Vitocrossal 300
CT3

below

below

MEA# 148-07-E
CT3 17
CT3 22
CT3 28
CT3 37

This trademark is registered with the U.S. Patent and Trademark Office.

H4005.1C
H4006.1C
H4007.1C
H4008.1C

CT3 46
CT3 57
CT3 72
CT3 89

H4009.1C
H4010.1C
H4011.1C
H4012.1C

119

Approval and Listing Overview


as of September 1, 2014

Biomass Heating Boilers

Pyrot
KRT

CSA

CRN

below

KRT 150

KRT 220

KRT 300

KRT 400

KRT 540

Pyrotec
KPT

KPT 390

KPT 530

KPT 720

KPT 950

KPT 1250

120

AHRI

EcoLogo

NY

MASS

CEC

ASME Ener
Star

Ener
Verif.

Price List
Section

not
reqd

not
reqd

30psig M7945.5C
60psig M7946.5C
30psig M7947.5C
60psig M7950.5C
30psig M7952.5C
60psig M7939.5C
30psig M7941.5C
60psig M7942.5C
30psig M7944.5C
60psig M7954.5C
below

30psig M7980.5C
60psig M7978.5C
30psig M7985.5C
60psig M7984.5C
30psig M7966.5C
60psig M7960.5C
30psig M7965.5C
60psig M7964.5C
30psig M7956.5C
60psig M7958.5C

Viessmann North America


United States Contact Information
or under Sales Network at www.viessmann.us
Sales Representative, U.S.

AK, N. ID, OR, WA


PSI Heating LLC
Tel: (206) 860-7970
Fax (206) 860-7990
hydronicbill@earthlink.net
N. AL
Jamco Inc
Tel: (205) 833-3390
S. AL, MS
Hydro Technologies
Tel: (251) 478-1104
Fax: (251) 478-1105
AR, OK
Boone and Boone Sales
Tel: (800) 582-7037
Fax ( 405) 521-1448
jimc@2boondsales.com
N. CA, HI, NV
(Less Elko County)
Patterson Sales
Tel: ( 916) 992-6320
Fax (916) 992-6329
info@pattersonsales.com
CO, MT, NM, WY
MJM Associates, Inc.
Tel.: (303) 790-7000
Fax ( 303) 790-1133
jmarklowitz@mjmassoc.com
CT
Heat Tech Associates, Inc.
Tel: (860) 482-6321
Fax (860) 482-9601
Heat-tech@cox.net
D.C.,
(New Castle County Only),
MD, VA
Joyce Agency
Tel: (800) 291-9298
Fax (703) 886-2332
rjenkins@thejoyceagency.com
DE (New Castle County
Only), S.NJ, E. PA
Stroh Sales Associates
Tel: (610) 933-6400
FL
Al Karch Energy Services
Tel: (954) 963-3762
Fax: (954) 964-8877

Direct
Representative, U.S.

Viessmann Manufacturing Co. (US), Inc

S. ID, NV (Elko County), UT,


W.WY
Intermountain Sales and
Marketing, Inc.
Tel: (801) 936-0228
Fax (801) 936-0227
joe@intermountainsales.net

AZ, IA, KS, MO, NE, TN, PR,


and Guam
Viessmann Manufacturing
Company (US), Inc.
Tel: (401) 732-0667
Fax (401) 732-0590
info@viessmann-us.com

Viessmann Manufacturing
Co. (US), Inc.
45 Access Road
Warwick, RI 02886
Tel: (401) 732-0667
Fax (401) 732-0590
info@viessmann-us.com

West Mountain Reg. Sales


Manager
CO, ID, MT, NV, NM, UT, WY
Carol Fey
Tel: (401) 732-0667
Fax (401) 732-0590
fcar@viessmann.com

IL, IN
Gunn & Pegelow
Tel: (847) 573-7030
Fax (847) 573-1824
CSR@gunnpegelow.com

NE, MA, E.NH,


N.E. Territory Sales Manager
Tom Fullerton
Tel: (603) 412-2250
Fax (401) 732-0590
fult@viessmann.com

Sales Director (East)


Steve David
Tel: (401) 732-0667
Fax (401) 732-0590
dav@viessmann.com

West Pacific Reg. Sales


Manager
AK, AZ, CA, HI, NV, OR, WA
Amy Givan
Tel: (401) 732-0667
Fax (401) 732-0590
giva@viessmann.com

LA
Gaudin Equipment
Tel: (504) 466-7661
MI, OH
EM Mechanical Sales
Tel: (616) 819-0255
EMsales@charter.net
W. MA, W.NH, VT
Paul Ross Associates, Inc.
Tel: (413) 543-8730
Fax (413) 543-8737
pross.pra@comcast.net
MN, ND, SD, WI
Mulcahy Company Inc.
Tel: (651) 686-8580
Fax (651) 686-8588
tschmelling@mulcahyco.com
CENTRAL PA
Distributor Associates
Tel: (717) 392-1166
W. PA, WV
Pinnacle Sales
Tel: (412) 461-9663
TX
GOES Heating Systems
Tel: (713) 699-5344
Fax (713) 699-0915
calvin@goesheatingsystems.
com
NC, SC
Wm. T. Royster & Associates,
Inc.
Tel: (800) 438-7829
info@roysterassociates.com

GA
BSI Mechanical Sales and
Service
Tel: (678) 213-4026
Fax (678) 213-4032
sales@bsimechanical.com

This trademark is registered with the U.S. Patent and Trademark Office.

S.MA, RI
N.E. Territory Sales Manager
Pat Lillie
Tel: (401) 742-7669
Fax (401) 732-0590
lilp@viessmann.com
ME
N.E. Terrritory Manager
Jim Bolduc
Tel: (207) 532-8500
Fax (401) 732-0590
bolj@viessmann.com
E. Upstate NY
NY Territory Sales Manager
Tim Rose
Tel: (518) 321-4962
Fax (401) 732-0590
rset@viessmann.com
W. Upstate NY
Rich Davis
NY Territory Sales Manager
Tel: (401) 374-6240
Fax (401) 732-0590
davr@viessmann.com
Renewables Sales Manager
Bede Wellford
Tel: (207) 956-2799
Fax (401) 732-0590
wefb@viessmann.com

Mid-West Reg. Sales


Manager
IA, IL, IN, KS, KY,MI, MN,
MO, NE, ND,
OH, SD, WI
Kevin Pheney
Tel: (401) 732-0667
Fax (401) 732-0590
pnyk@viessmann.com
New England Reg. Sales
Manager
CT, MA, ME, NH, RI, VT
Kevin Flynn
Tel: (401) 732-0667
Fax (401) 732-0590
flyk@viessmann.com
New York, New Jersey,
Pennsylvania and W.Virginia
Reg. Sales Manager
Michael Klas
Tel: (401) 732-0667
Fax (401) 732-0590
ksmc@viessmann.com
Southern Reg. Sales
Manager
AL, AR, DC, DE, FL, GA, LA,
MD, MS, NC, OK, SC, TX, VA
Terry Stohs
Tel: (401) 732-0667
Fax (401) 732-0590
stht@viessmann.com

NYC, Long Island


NY Territory Sales Manager
Adam Heidt
Tel: (631) 278-4781
Fax: 401-732-0590
hdta@viessmann.com
N. NJ
New Jersey Territory Manager
Barbara Doyle
Tel:(973) -879-2919
doyb@viessmann.com

121

5167 591 Effective 1-Sep-14; Revised 19-Feb-15